RED-E CABINET ®
RED-E CABINET
Integrated Fire Protection Packages
Features and Benefits
• Aesthetically Pleasing
Appearance
• Professionally Assembled
• Minimal Installation Time
• Internally Pre-Wired
• UL/ULC/FM Components
• Custom Manufactured
• Sizes 11⁄2 ", 2", 3", 4" & 6"
Preaction, Double Interlock,
and Deluge Packages
• Model DV-5 Deluge Valve
(Standard)
• All Gauges and Panel Display
are Visible Externally
• Supply Pipe to Cabinet From Either Side
General Description
The Red-E Cabinet is a pre-assembled
fire protection valve package enclosed
within a free-standing cabinet designed to
occupy minimal floor space and to provide an aesthetically pleasing enclosure
for a fire protection valve riser. The entire
package is pre-wired and the water inlet
and outlets to the valve riser are grooved
to provide minimal installation time. The
valve package includes the system (manual) shut-off control valve, automatic
water control valve, as well as waterflow
and supervisory switches. Where system
air pressure is required for either supervision or automatic water control valve
actuation. An air compressor and associated controls are also provided.
Integral to the Red-E Cabinet door is a
control panel and back-up batteries for
providing electrical alarm, supervisory,
and trouble functions. All switches within
the cabinet are pre-wired to the control
panel, making the electrical connections
for power, detection circuits, and alarms
(continued on back)
• System Discharges Vertically Through
Top of Cabinet
• Furniture Grade Rollers (4) are Standard
at Bottom of Cabinet
• Model DV-5 Deluge / Preaction Valve
(Standard)
• Potter 4410 Releasing Control Module
(Standard)
• Model BFV-1 Butterfly Control Valve
(Standard)
All Four Side Panels Easily
Removed For Ease of
Maintenance
Technical Data
The Red-E Cabinet is constructed of 14 gauge steel, and is free-standing. The standard paint finish is bright red. The front door of the enclosure is fully hinged to maximize access to the enclosure. Internal controls that provide functions to reset a system
after operation (e.g., alarm control valve, alarm test valve, main drain valve, etc.) are
individually tagged for easy identification. All prefabricated piping is Schedule 40 black
steel, and the valve trim is galvanized Schedule 40 steel pipe. All electrical junction
boxes meet the requirements of NEMA® 12.
Component Approvals
UL, C-UL Listed, and/or FM Approved
(Always refer to Technical Data Sheet for complete description of all Listing criteria, design parameters,
installation instructions, care and maintenance guidelines, and our Limited Warranty.)
RED-E CABINET ®
A
Supply Header
B
System Discharge
C
Drain Header
Nominal Riser Size
Large Cabinet
Small Cabinet
1 ⁄2 Inch
2 Inch
3 Inch
4 Inch
6 Inch
(DN40)
(DN50)
(DN80)
(DN100)
(DN150)
11⁄2"
3"
4"
6"
2"
(38.1 mm)
(76.2 mm) (101.6 mm) (152.4 mm)
(50.8 mm)
11⁄2"
3"
4"
6"
2"
(38.1 mm)
(76.2 mm) (101.6 mm) (152.4 mm)
(50.8 mm)
2"
2"
3
3
11⁄4" NPT
⁄4" NPT
⁄4" NPT
(50.8 mm)
(50.8 mm)
D
Drip Funnel Drain
11⁄4" NPT
Connection
Description
Port
J
B
Notes:
1
11⁄4" NPT
11⁄4" NPT
11⁄4" NPT
11⁄4" NPT
1. Connections are Grooved except where noted by NPT thread designations.
2. All connections except System Discharge are made internal to cabinet.
J
B
G
G
Nominal Dimensions in Inches and (millimeters)
E
F
F
H
J
K
L
M
N
P
R
281⁄2
223⁄4
131⁄4
10
5
10
101⁄8
4
41⁄4
4
691⁄4
Small (1759.0) (723.9) (577.9) (336.6) (254.0) (101.6) (127.0) (254.0) (257.2) (101.6) (108.0)
141⁄8
113⁄16
36
18
141⁄8
757⁄8
31
61⁄8
53⁄16
2
7
Large (1927.2) (914.4) (787.4) (457.2) (358.8) (50.8) (177.8) (358.8) (284.2) (155.6) (131.8)
Cabinet
Size
H
Electrical
Conduit
Connections
K
F
H
Electrical
Conduit
Connections
F
E
K
E
M
M
D
D
P
P
N
L
N
R
A
L
R
C
C
Deluge System Package
A
Preaction System Package
DV-5 Red-E Cabinet Matrix
P/N 5 2 - 8 X X - X - X - X - X
Valve
DV-5
Style
Size
Actuation
Device
Air Maintenance
Device*
Trim
Type
US /
Canada
Compressor
52
52
52
52
52
52
52
52
52
8
8
8
8
8
8
8
8
8
11/2" = 1
2" = 2
3" = 3
4" = 4
6" = 6
–
–
–
–
Deluge / Wet = 1
Deluge / Dry = 2
Deluge / Elec = 3
S/I Wet = 4
S/I Dry = 5
S/I Elec = 6
D/I Elec / Pneu = 7
D/I Elec / Elec = 8
–
None = 0
AMD-1 = 1
AMD-2 = 2
AMD-3 = 3
–
–
–
–
–
Galvanized = 1
Black = 2
Brass = 3
–
–
–
–
–
–
USA = A
Canada = C
–
–
–
–
–
–
–
None = 0
1/6 hp 110 Gal = 1
1/3 hp 215 Gal = 2
1/2 hp 335 Gal = 3
3/4 hp 435 Gal = 4
1 hp 610 Gal = 5
1 hp 900 Gal = 6
1 hp 1200 Gal = 7
S/I Compressor = 8
S/I = Single Interlock • D/I = Double Interlock
*Not all D/I require an Air Maintenance Device
(continued from front)
the only remaining electrical connections to
complete the system.
In addition to the integral control panel, windows
have been provided in the Red-E Cabinet door
for viewing the releasing panel functions and
essential system pressure gauges. A lock for the
control panel access door is standard, and a
lock for the cabinet door is optional.
The Red-E Cabinet has been designed to readily incorporate 1-1/2", 2", 3", 4" & 6" valve risers
for the following types of systems:
• Deluge System – Electric Actuation
• Single Interlock Preaction System
• Double Interlock Preaction System
NEMA is a trademark of the National Electrical Manufacturers Association. RED-E CABINET and Tyco are either registered trademarks or trademarks of
Tyco and/or its affiliates in the United States and/or other countries. All other brand names, product names, or trademarks belong to their respective owners. Tyco Fire Products reserves the right to change product design and specifications without notice.
Tyco Fire Products
Technical Services
Ph: 800-791-9312
Fax: 800-791-5500
www.Tyco-Fire.com
Copyright © 2005 Tyco Fire Products LP. All rights reserved. Printed in USA /PF-RedE/4M/AB/05-05
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising