I18H013 - Treotham
Inductive Sensor
with IO-Link
I18H013
Part Number
Technical Data
Inductive Data
Switching Distance
12 mm
Correction Factors V2A/CuZn/Al
0,97/0,47/0,43
Standard Target
Mounting
Mounting A/B/C/D in mm
Mounting B1 in mm
Switching Hysteresis
Electrical Data
quasi-flush
18/46/36/5
0...28
< 10 %
Supply Voltage
10...30 V DC
Switching Frequency
600 Hz
Current Consumption (Ub = 24 V)
Temperature Drift
Temperature Range
Switching Output Voltage Drop
Switching Output/Switching Current
Residual Current Switching Output
Short Circuit Protection
Reverse Polarity and Overload Protection
Interface
IO-Link Version
Protection Class
Easy sensor configuration using the IO-Link interface
Innovative ASIC circuit technology
Integrated error display and error output
Minimal mounting clearance thanks to wenglor weproTec
36 × 36 mm
Mechanical Data
< 12 mA
< 10 %
-40...80 °C
<1V
100 mA
< 100 µA
yes
yes
IO-Link
1.0
III
Housing Material
CuZn, nickel-plated
Connection
M12 × 1; 4-pin
Degree of Protection
Function
IP67
Error Indicator
yes
Programmable switching frequency
yes
Programmable switching distance
8/10/12 mm
IO-Link
Switchable to NC/NO
Configurable as PNP/NPN/Push-Pull
Programmable error output
Connection Diagram No.
Suitable Connection Technology No.
The Inductive Sensors have not only been equipped
with ASIC, but rather with an IO-Link interface as well
for ideal integration into networks. As a result, a total of
three switching distances and two switching frequencies can be selected, and PNP/NPN as well as
NO/NC/antivalent options can be set as desired. This
reduces the number of variants while simultaneously
expanding the scope of functions.
Suitable Mounting Technology No.
Complementary Products
IO-Link Master
Inductive Sensors
704
2
150 152
1 = Switching Status Indicator
Sleeve M18×1 = 30 Nm
All dimensions in mm (1 mm = 0.03937 Inch)
Legend
Supply Voltage +
Supply Voltage 0 V
Supply Voltage (AC Voltage)
Switching Output (NO)
Switching Output (NC)
Contamination/Error Output
Contamination/Error Output
Input (analog or digital)
Teach Input
Time Delay (activation)
Shielding
Interface Receive Path
Interface Send Path
Ready
Ground
Clock
Output/Input programmable
Power over Ethernet
Safety Input
Safety Output
Signal Output
Maintenance
PT
(NO)
(NC)
Platinum measuring resistor
not connected
Test Input
Test Input inverted
Trigger Input
Analog Output
Ground for the Analog Output
Block Discharge
Valve Output
Valve Control Output +
Valve Control Output 0 V
Synchronization
Receiver-Line
Emitter-Line
Grounding
Switching Distance Reduction
Ethernet Receive Path
Ethernet Send Path
Interfaces-Bus A(+)/B(–)
Emitted Light disengageable
Magnet activation
Input confirmation
Contactor Monitoring
Encoder A
Encoder B
Digital output MIN
Digital output MAX
Digital output OK
Synchronization In
Synchronization OUT
Brightness output
Wire Colors according to
DIN IEC 757
Black
Brown
Red
Orange
Yellow
Green
Blue
Violet
Grey
White
Pink
Green Yellow
Mounting
Specifications are subject to change without notice
704