Shaker Accessories
Instruction Manual
Shaker Accessories
Table of Contents
Warnings
Universal, Dedicated and Culture Style Platforms
Adjustable Platforms and Large Vessel Carriers
Separatory Funnel Platform
Tier Braces
Test Tube Racks - Pivoting (Full Size)
Test Tube Racks - Stationary (Full Size)
Test Tube Racks - Stationary (Half Size) Flask Clamps
Microplate Clamp
Warnings
CAUTION! Install platforms on to shakers before adding flask clamps,
test tube racks or other accessories. Two people may be needed for
installation of extra large and jumbo platforms.
CAUTION! When using platform accessories, tighten mounting
screws periodically. If excessive noise occurs while running unit, stop
immediately and check mounting screw tightness.
PLEASE NOTE: Unit must be in standby mode before any platforms
or accessories are attached to the shaker.
1
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1
2
3
3
4
5
5
6-7
8
9
Warranty
Manufacturer warrants this product to be free from defects in material and
workmanship when used under normal conditions for five (5) years. Register
your equipment of instrument online at www.vwrsp.com/warranty for
US residents or www.vwrcanlab.com/warranty for Canadian residents. For
your reference, make a note of the date of purchase and supplier here.
Date of Purchase:
Supplier:
Platforms
Universal, Dedicated and Culture Style Platforms
For basic attachment of the platform to the shaker’s tray, please refer to the installation instructions below for your specific model.
1. Installation of Platforms for Models 3500, 3750 and 5000
2. Installation of Platforms for Models 10000 and 15000
The black mat does not have to be removed from the shaker tray.
Loosen the four (4) screw knobs on the shaker tray approximately 1⁄4”.
Place platform on shaker tray by aligning the slots on the two (2) sides
of the platform over the four (4) screw knobs. Allow the platform to rest
on the screws. When aligned and seated on the screws, hand-tighten
the four (4) knobs. DO NOT over tighten.
Before mounting the platform, remove the mat from the shaker’s tray
to expose the four (4) threaded openings. Hold the accessory platform
from the outside and align the platform over the threaded openings on
the tray. Place the accessory platform over the shakers’ tray noting the
four (4) threaded openings. Use a Phillips head screwdriver to tighten
the integrated screws to the mounting holes in the shakers tray. DO NOT
over tighten.
Please note: Accessories larger than 13 x 13” will have two (2) flanges
with slots on the underside of the platform. Align the slots over the knobs
and hand tighten from the under side of the platform.
2
Platforms (cont’d)
Adjustable Platforms and Large Vessel Carriers
Separatory Funnel Platform
Package Contents
Package Contents
(1) Platform for mounting bars
(4) 18” padded bars
(8) Screw knobs
Adjustable
Platforms and Large Vessel Carriers are mounted to the shaker
tray in the same manner as the other platforms. The adjustable bars will
require minor assembly. Place the bar in the desired location across the
platform so the threaded end is resting in the open slots of the platform.
Screw the knob to each end of the bar to secure. Repeat with the remaining
bars.
3
(1) 18 x 18 universal style platform
(3) Pair of separatory funnel clamps
(6) 10-32 x 1/2” phillips pan head screws
(6) Screw knobs
Separatory Funnel Platforms are mounted to the shaker tray in the same
manner as the other platforms. To secure the separatory funnel clamps, line
up the openings in the clamp pairs with the openings in the platform that is
appropriate for your funnel. Use the pan head screws for the shorter clamp.
Set the funnel in place. Line up the longer clamp after placing the tapered
neck into the opening. Use the screw knobs to secure in place.
Tier Braces
Tier Braces
Package Contents
(4) Tier braces
(32) 1/4-20 x 3/4” hex head screws
(32) 1/4-20 jam hex head nuts
Align
the tier brace’s mounting holes to the mounting holes on the platform.
The brace should be on the outside of the platform. Place a hex screw
through the brace and platform. Place the hex nut on the end of the screw
and tighten. A 7/16” socket wrench can be used to aid in tightening the nut.
Attach the other three (3) braces to the same platform before securing to the
second platform.
Attach all four (4) braces to the second platform. After the two (2) platforms
are secured to the four (4) braces, secure to the shaker’s tray following the
instructions in the Platform Installation section (page 2).
4
Test Tube Racks
Pivoting - full size (not for use on Mini Shakers)
Stationary - full size (not for use on Mini Shakers)
Package Contents
Package Contents
(4) 10-32 x 5/16” flat head phillips screw
(1) Adjustable angle stainless steel rack holder (2 piece)
(1) Test tube rack (removable)
A Universal Platform is required in order to secure the rack to the shaker.
Line up the four (4) openings on the bottom of the outer rack with the four
(4) compatible openings on the Universal Platform. Secure with the four (4)
screws provided. If a tilt angle is desired, loosen wing knobs, tilt inner holder
and tighten knobs. To maximize the platforms capacity for holding racks in the
stationary position, remove the outer holder and secure the inner holder to the
Universal Platform using the four (4) openings on the bottom of the inner holder.
5
(2) Mounting knobs
(2) Washers
(1) Test tube rack
A Universal Platform is required in order to secure the rack to the shaker.
Universal Platforms must be 18 x 18” or larger.
Line up the two (2) openings on the sides of the test tube rack with the two
(2) compatible openings on the Universal Platform. Place the washer on
top of the opening on the test tube rack, place the clamp knob through the
washer and rack, and hand tighten the clamp knob to the platform. Universal
Platforms must be 18 x 18” or larger.
Test Tube Racks (cont’d)
For basic attachment of the platform to the shaker’s tray, please refer to the installation instructions below for your specific model.
Stationary - half size
The hardware used depends on the shaker’s tray or platform. Not all hardware will be used. See below for your specific shaker:
Package Contents
(2) Brackets (not needed when attaching to a Mini Shaker)
(4) 10-32 x 3/8” pan head Phillips screw
(2) 10-32 x 3/16” pan head Phillips screw
(1) Test tube rack
1. Open Air Mini Shakers
2. Incubating Mini Shakers
USE: (2) 10-32 x 3/16” pan head phillips screws
No hardware is required to secure the rack to the shaker’s tray.
Looking at the rack, the clip will be on the left and the slot opening will be
on the right. Line up the slots on the rack with the openings on the platform
and use the (2) 3/16” screws to secure. The clip will press into the side of the
shaker’s tray.
Line up the side of the rack, without the clip, to the shaker’s tray. The clip will
press in to the other side of the shaker’s tray.
6
Test Tube Racks (cont’d)
For basic attachment of the platform to the shaker’s tray, please refer to the installation instructions below for your specific model.
Stationary (half size)
3. Full Size Shakers (Model 3500, 3750, 5000, 10000 and 15000)
A Universal Platform is required in order to secure the rack to the shaker.
USE: (2) Brackets
(4) 10-32 x 3/8” pan head phillips screws
Place the two (2) brackets on the Universal Platform approximately 7 3/4” apart with
the openings in the bracket against the platform and the side on the inside, next
to where the rack will sit (see illustration). Align all four (4) openings with four (4)
compatible openings in the platform. Using the four (4) 3/8”, secure to the platform.
When mounting the rack, place the side without the clip in first and then push down
on the side with the clip. The clip should give you the tension you need to secure or
remove the rack. If is it too tight or too loose, bend the clip accordingly.
7
Flask Clamps
Flask Clamps (stainless steel)
Flask Clamps (pvc coated)
Package Contents
Package Contents
(1) Flask or bottle clamp
(1) 10-32 x 5/16” flat head phillips screw (for 10mL through 500mL)
(5) 10-32 x 5/16” flat head phillips screws (flask clamps 1L and larger)
(1) Extension spring (clamps 50mL and larger)
Line up the opening(s) in the clamp to the openings in the platform. Hand
tighten screw(s) with a Phillips head screwdriver. Insert the flask or media
bottle into the clamp and wrap the supplied spring around the neck of the
clamp to hold secure.
(1) Flask clamp
(3) 10-32 x 5/16” flat head slotted screws
(3) ID 7/32” x OD 3/8” washers
Line up the opening(s) in the clamp to the openings in the platform. Hand
tighten the screw(s) on top of the washer with a flat head screwdriver. Insert
the flask into the clamp.
8
Microplate Clamp
Microplate Clamp
Package Contents
(1) Microplate clamp
(2) 10-32 x 3/8” phillips pan head screws
Line up the openings in the clamp to the openings in the platform. Hand
tighten the screws. Insert the microplate into the clamp.
9
Notes
10
Manufactured by:
TROEMNER, LLC
201 Wolf Drive • PO Box 87 • Thorofare, NJ 08086-0087
Phone: 856-686-1600 • Fax: 856-686-1601 • E-mail: troemner@troemner.com
www.troemner.com
715069-00 (REV 4 - 8/16)
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising