Installation Sheet
Pre- and post-installation
procedures
When installing additional options in your HP ProLiant SL165z G7 Server, observe
the following procedures:
Pre-installation procedures
1. Turn off the server and all the peripherals connected to it.
2. Disconnect the AC power cord from the power supply cable socket located on the server rear panel to reduce the risk of electrical shock.
3. If the server is installed in a rack, remove the server and place it on a flat surface.
4. Remove the server from the chassis by following the procedures described later in the “Removing the server” section.
Identifying server components
Front panel components
Post-installation procedures
Figure 1 Front Panel Components / 2 SL165z Servers
Second edition (April 2010)
Part number 602405-002
Item Description
1
System maintenance jumper
2
PCIe x16 slot
3
Processor 1
4
Mgmt card connector
5
DIMM slot 12 for processor 1
6
DIMM slot 1 for processor 1
Description
7
DIMM slot 12 for processor 2
1
Tray handle
8
Processor 2
2
Tray latch
9
4-pin power connector
3
SD reader port (optional)
10
24-pin power connector
4
Front panel USB 2.0 port 0/1
11
Fan connector 1
5
Serial port
12
Fan connector 2
6
GbE LAN port for NIC 4
13
DIMM slot 1 for processor 2
14
Backplane I2C connector
7
VGA port
15
8-pin power connector
8
GbE LAN port for NIC 2
16
Fan connectors 3/4
9
Power switch/LED
17
Fan connector 5
10
System health LED
18
Internal USB 2.0 port
11
GbE LAN port for NIC 1
19
SD card USB 2.0 port
12
Low-profile PCI expansion card slot cover
20
Front panel USB 2.0 port
13
GbE LAN port for NIC 3
21
SAS LED connector
14
Mgmt port (optional)
22
Fan connectors 6/7
15
Front UID LED/switch
23
Mini-SAS connector for SATA
24
Power backplane control connector
Rear panel components
25
Front panel header
26
TPM connector
Figure 2 Rear Panel Components
27
PCIe x4 slot
28
ODD 2 SATA connector
29 ODD 1 SATA connector
30
3 V CMOS battery (CR2032)
31
NMI jumper
Item
Server configuration resources
Important Safety Information
Læs dokumentet Vigtige sikkerhedsoplysninger på dokumentations-cd'en, før produktet installeres.
Prima dell'installazione, leggere sul CD le Informazioni importanti sulla sicurezza.
Item Description
1
Power supply 2 cable socket
2
Power supply 1 cable socket
3
Rear UID LED
1. Be sure all components are installed according to the described step-by-step instructions.
2. Check to make sure you have not left loose tools or parts inside the server.
3. Reinstall the PCI cage, air baffle, peripherals, and system cables that you
have removed.
4. Reinstall the server into the chassis.
5. Connect all external cables and the AC power cord to the system.
6. Press the power button on the front panel to turn on the server.
Removing the server
You need to remove the server from the chassis before you can remove or replace a
server component.
CAUTION: When the servers are operational, tray blank 577723-001
(Option Kit P/N 579069-B21) must be installed in the server slot after
removal of the server.
To remove the server:
1. Press the tray latch to release the tray handle.
2. Rotate the tray handle to disengage the power connector.
3. Pull the server tray assembly out of the chassis.
4. Insert the tray blank into the server slot.
Figure 4 Removing the Server
Figure 5 Installing the Tray Blank
In addition to this Installation Sheet, other resources are available for more
information regarding the configuration and maintenance of your server:
• For safety information and detailed procedures relating to installation of options,
refer to any installation instructions that came with the option, as well as the
HP ProLiant SL165z G7 Server Maintenance and Service Guide.
• For safety information and detailed procedures related to the rest of the steps
listed in the “Configuring the Server” section, refer to the relevant chapter of the
HP ProLiant SL1000/6000 Series Server User Guide.
• For information relating to system BIOS configuration and operating system
installation, refer to the relevant section of the HP ProLiant SL165z G7 Server
Software Configuration Guide.
• You can also access additional information and documentation from the HP
website at www.hp.com.
Server configuration overview
Les "Viktig sikkerhetsinformasjon" på dokumentasjons-CDen før du installerer dette produktet.
The steps listed below give an overview of the necessary setup procedures for
preparing the HP ProLiant SL165z G7 Server for operation:
1. Connect the AC power cord and peripheral devices.
2. Power on the server.
3. Press “F10” to enter BIOS setup.
4. Note the server BIOS version.
Tärkeisiin turvatietoihin" Documentation CD -levyllä ennen tuotteen asentamista.
Läs dokumentet Viktig säkerhetsinformation på dokumentations-cd:n innan du installerar denna produkt.
5. Verify the server BIOS version against the latest BIOS version listed for this server.
6. If you do not have the latest BIOS, update the BIOS now. Refer to the
HP ProLiant SL165z G7 Server Maintenance and Service Guide available on
the HP website: www.hp.com.
Installing a hard drive
One server tray can accommodate two LFF or four SFF hard drives, and the chassis
can accommodate two server trays for up to four LFF or eight SFF hard drives. The
server supports both SAS and SATA hard drives.
CAUTION: Drives can be damaged by static electricity. Before handling
drives, touch an unpainted metal surface to discharge static electricity.
To install a hard drive in the server tray:
1. Unlock the HDD carrier latches.
2. Rotate the HDD carrier handle up.
3. Align the five pins on the HDD carrier to their holes on the two sides of the server tray, and insert the HDD into the server tray
4. Push the HDD along the direction of the arrow to lock the five pins.
5. Rotate the HDD carrier handle down.
6. Lock the HDD carrier latches.
Figure 6 Installing the Hard Drive
CAUTION: DIMM slots are structured to ensure proper installation. If you
insert a DIMM but it does not fit easily into the slot, you may have inserted
it incorrectly. Reverse the orientation of the DIMM and insert it again.
Figure 9 Installing the Heat Sink Assembly
Figure 11 Installing the SD Card Reader Module
NOTE: You must use the slotted driver to remove the knock-out.
Installing a processor
To install the processor:
1. For AMD processor with installation tool, use the processor installation tool to
insert the processor into the socket, using the keys on the processor.
2. Remove the processor installation tool.
3. Engage the retention plate and the load lever.
Figure 8 Installing the Processor
CAUTION: Be sure that the heat sink sits squarely on the processor, or
overheating and damage to the processor may occur.
NOTE: When installing two heat sinks, it is recommended to put the heat sinks with
the 15-fin side facing the DIMMs.
Installing a memory module
CAUTION: DIMMs can be damaged by improper handling. Always
use an anti-static wrist strap and grounding mat, and discharge static
electricity before touching DIMMs.
For processor removal, reverse the above installation procedures.
CAUTION: With the load lever and the retention plate disengaged, hold
the processor by its edges and align it over the empty processor socket.
Make sure that you properly align the processor with the orientation notch
on the socket.
CAUTION: To prevent overheating or a possible system crash, use only a
heat sink model specified for the HP ProLiant SL165z G7 Server.
NOTE: Refer to “System board components” in this document for the DIMM locations.
To install the memory module:
1. Align the notch on the bottom edge of the memory module with the keyed
surface of the DIMM slot and then fully press the memory module into the slot
until the holding clips snap back in place.
Figure 7 Installing the Memory Module
CAUTION: Align pin 1 on the processor with pin 1 on the processor
socket, or pin damage will occur.
CAUTION: HP recommends using Shin-Etsu X-23-7783D thermal grease
compound for your ProLiant server. Apply the grease to the top of
the processor in either a 5 “Dot” or “S” shaped pattern. Ensure even
distribution.
To install the heat sink:
1. Properly align the heat sink spring-loaded screws to the system board mounting
holes.
CAUTION: Do not over-tighten the spring-loaded screws to prevent them
from breaking off. A maximum torque of 7 inch-lb is set for each screw.
Rotate the heat sink a few degrees to the left and right to break the
bonding of the thermal grease before removing the heat sink from the
processor.
IMPORTANT: If the heat sink has been removed for any reason, it is critical
that you apply more thermal interface material to the integrated heat
spreader on the processor to ensure proper thermal bonding between
the processor and the heat sink. Clean the contact surface of both the
processor and heat sink with an alcohol pad, then re-apply an HPapproved thermal interface material before reinstalling the processor. Use
a pattern of five dots when applying the thermal interface material—one
dot in the center, and one dot at each corner.
CAUTION: For proper cooling, do not operate the server without the top
cover, air baffle, expansion slot covers, or blanks installed. For additional
information, see the user guide. If hot-plug components are supported,
minimize the amount of time the top cover is removed.
Installing the dedicated
management port card
To install the dedicated management port card:
1. Remove the dedicated management port knock-out from the front panel of the
server.
2. Insert the dedicated management port card into the mgmt card connector on
the system board.
3. Tighten the screw clockwise to secure the dedicated management port card to
the system board.
Figure 12 Installing the Dedicated Management Port Card
Installing the system fans
The figure below identifies the system fans by their device number and shows their
corresponding cable connections.
Figure 10 Installing the System Fans
2. Tighten the spring-loaded screws clockwise to secure the heat sink connection to
the system board.
Additional documentation
For additional documentation, refer to HP ProLiant DL165/SL165z G7 Easy Set-up
CD. You can also access additional information and documentation from the HP
external website, either by connecting directly or through the Easy Set-up CD.
Legal notices
Memory Module Population Order
© Copyright 2010 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only warranties
for HP products and services are set forth in the express warranty statements accompanying
such products and services. Nothing herein should be construed as constituting an additional
warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
Processor memory socket
Rank support per memory socket
RDIMM Population order without QR
UDIMM Population order without QR
Population order with QR along with SD/DR
Processor memory bank number
NOTES:
Installing the SD card reader
module
To install the SD card reader module:
1. Remove the SD card reader module knock-out from the front panel of the server.
2. Align the SD card reader module to the front panel, and tighten the screw that
secures the module to the server.
3. Connect the USB cable to the SD card reader module USB connector and link
the other side of the USB cable connector to the system board.