Mounting the enclosure Mounting the AC4 AC Duplex Outlet Box

Mounting the enclosure Mounting the AC4 AC Duplex Outlet Box
PRINTER'S INSTRUCTIONS:
INSTR,INSTL,E18 - LINEAR P/N: 222796 X4 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000" X 15.000" - FOLDING: 2-FOLD ALTERNATE, 2-FOLD HORIZONTAL INTO THIRDS, (FINISH HAS LOGOS SHOWING) - SCALE: 1-1 - SIDE 1 OF 2 (FRONT)
ELAN
modules attach from the top
1
1) Hook from the top
2) Swing into place
3) Push button to lock
3
E18
18” enclosure
C18
18” cover
AC4
4 AC Outlet Accessory
Telephone Expansion Hub (4 lines x 8 phones)
Expansion
Ports
All ELAN
modules are
grid compatible.
TM
2
Telephones
R
4
T
In
R
3
T
R
2
T
Out
R
1
T
TM
Mounting the enclosure
Mounting the AC4 AC Duplex Outlet Box
1. For tab mounting, install the mounting tabs
AC4 installs in any of 4 locations
A. Select the proper slots for the wallboard thickness.
Slots A - For 3/8” wallboard
Slots B - For 1/2” wallboard
Slots C - For 5/8” wallboard
A
C
B
B. Insert m o u n t i n g tab.
(Don’t worry if the tabs seem
loose - they tighten up when
screwed to the studs.)
B
A
C
The AC4 accessory brings AC power
inside the enclosure. The AC4 gives the
installer a clean location to mount power
adapters. Mount the AC4 in any corner of
the enclosure using the four #6 screws
provided. Installation of AC outlets should
be done only by a qualified electrician.
2. Attach enclosure
Use the four screws provided.
(The screws will force mounting tabs
flat, tightening the tab.)
1/2” knockouts for 120VAC
The AC4 provides space for 2
standard duplex receptacles.
Wires should exit the AC4 using
the grommets provided. The
grommets may be cut as shown.
OEM
AC ADAPTOR
Wood
Stud
Part no.: 123-456
U
L
Or, when mounting without
the tabs, use screws in the
four slide mount slots.
1/8”
Enclosure
Wallboard
Stud
Using wire ties with the
When mounting without using
the mounting tabs adjust the
enclosure to protrude 1/8”
beyond the wallboard surface.
Installing cables
1) Fold back tip of
wire tie and insert
into hole
2) Push wire tie slowly
into hole until tip
snaps to next hole
grid
3) Pull tip through
second hole
4) Works
horizontally too
Grommet
Remove the knockouts as needed
and line the holes with the grommets provided.
Grommet
Installing the cover
Remove paint shield and save.
Route cabling into enclosure.
A 2” diameter coupling tube (not included)
may be used to join 2 or more enclosures.
After cabling is routed, reverse paint
shield and return it to the enclosure to
protect cabling.
If AC4 is installed, fold flaps on the paint
shield to bend the shield over the AC4
outlet accessory.
An old electrician’s trick …
When hanging a heavy cabinet cover,
insert two nails (included) through the
mounting holes on the cover. Guide the
nails into the mating holes on the
enclosure and let the cover hang from
the nails while you attach the screws.
New tri-thread cover mounting
Grounding the cabinet
When used with model AC4 accessory, the grounding lug on the AC4
is used. Standard #10-32 grounding screws may be added to the
tapped holes top or bottom.
PRINTER'S INSTRUCTIONS:
INSTR,INSTL,E18 - LINEAR P/N: 222796 X4 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000" X 15.000" - FOLDING: 2-FOLD ALTERNATE, 2-FOLD HORIZONTAL INTO THIRDS, (FINISH HAS LOGOS SHOWING) - SCALE: 1-1 - SIDE 2 OF 2 (BACK)
Bottom knockout accepts standard J-box.
Distribute antenna or cable TV to every
room of the house. Some models include bidirectional amplifiers for interactive cable
systems. Some models include modulator
inputs and IR engines.
Coax panels
Remove rectangular knockout. Drop
in J-box and attach with #6 sheet
metal screws.
Wall plate systems for all rooms. The typical room gets TV
and telephone. The home office wall plate adds data ports.
The media center wall plate adds satellite feeds.
Wall plates
Quick, flexible mounting system
1
Connections for 1-4 phone lines to
every room. Starter hub adds RJ31X jack for security system dialer.
R
T
1
R
T
2
R
T
3
R
T
4
Out
RJ31X
From
Telco
Expansion
Ports
Telephone hubs
Telephones
Telephone Master Hub (4 lines x 6 phones)
Model TH31SRG
Install upper right screw.
(#6 - #10)
Center screw on stud.
Place screw 8 1/4” from
desired top of enclosure.
Termination blocks for the CAT-5 cables,
Ethernet hubs. Bring the Internet to any
room in the home. Or create a home data
network.
Data Hub (8 cables, TIA-568A) Category 5 Compliant
Model DH8
Data hubs
RF splitters and telephone punch
downs. When it is time to upgrade,
just snap this module out and
replace with one of more of the
more sophisticated modules.
Basic RF & Telco
There’s an ELAN
Structured Wiring product for almost every Data,
Telephone or RF distribution application . . .
2
Slide enclosure on screw.
Use screwdriver to select
3/8”, 1/2” or 5/8” drywall setback.
Tighten screw.
Slide enclosure on
screw until
screwdriver hits stud.
18” Enclosure Cover
C18
18” Structured Wiring Enclosure
E18
3
Install other right side screw.
(Use screwdriver as above to set
the depth of the enclosure.)
Limited Warranty
ELAN HOME SYSTEMS, L.L.C. ("ELAN") warrants the C18 and E18 to be free from defects in materials and
workmanship for a period of 15 years from the date of purchase. If within the applicable warranty period above
purchaser discovers such item was not as warranted above and promptly notifies ELAN in writing, ELAN shall repair
or replace the items at the company's option. This warranty shall not apply (a) to equipment not manufactured by
ELAN, (b) to equipment which shall have been installed by other than an authorized ELAN installer, (c) to installed
equipment which is not installed to ELAN's specifications, (d) to equipment which shall have been repaired or altered
by others than ELAN, (e) to equipment which shall have been subjected to negligence, accident, or damage by
circumstances beyond ELAN's control, including, but not limited to, lightning, flood, electrical surge, tornado,
earthquake, or any other catastrophic events beyond ELAN's control, or to improper operation, maintenance or
storage, or to other than normal use of service. With respect to equipment sold by, but not manufactured by ELAN, the
warranty obligations of ELAN shall in all respects conform and be limited to the warranty actually extended to ELAN by
its supplier. The foregoing warranties do not cover reimbursement for labor, transportation, removal, installation, or
other expenses which may be incurred in connection with repair or replacement.
Except as may be expressly provided and authorized in writing by ELAN, ELAN shall not be subject to any other
obligations or liabilities whatsoever with respect to equipment manufactured by ELAN or services rendered by ELAN.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESSED AND IMPLIED
WARRANTIES EXCEPT WARRANTIES OF TITLE, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
4
Install both left side screws. (Use
screwdriver as above to set the depth
of the enclosure.) The mount will flex
to attach the enclosure to the stud
without distorting the enclosure.
222796 X4