CONTAMINATION MONITORS
CSM-C Series
Contamination Sensor Module Comfort Series
Technical Specifications
General Specifications
Measured variables
Measurement ranges
Calibration accuracy
Description
The CSM Comfort Contamination Sensor Module is the plug-andwork solution for permanently monitoring fluid status by measuring
solid particle contamination and water saturation.
Designed for 24/7 operation, the CSM-C can be used for all hydraulic
and lubrication applications. With its own integrated power supply
and multi-voltage input, the CSM-C can be used in any hydraulic
conditions.
The CSM-C must be placed directly on the measuring site; it can
be easily connected to the customer controller (PLC) through its
integrated analog output.
The SMU 1200 Sensor Monitoring Unit is designed to be used as
a remote control and display accessory with reliable data storage
that integrates perfectly into the housing on the CSM-C; it can also
be conveniently positioned in the customer’s field of view using a
10-meter connecting cable.
Applications
• Hydraulic and lubricating fluids
• Continuous 24/7 operation
Advantages
•
•
•
•
Accessory to FCU 1000
Continuous measurement in lubricating fluids
Housing for use near the measuring site
Convenient display using SMU 1200
Contamination
ISO 4406, SAE AS
4059, NAS 1638
Water content
Level of saturation
Temperature
°F (°C)
Contamination ISO 9/8/7 ISO 25/24/23
Water content
0 to 100 %
Temperature
-25 to 100 °C
Contamination ± ½ ISO-Code
in calibrated range of ISO 13/11/10 ISO 23/21/18
Water content
± max. 2% (Full scale)
Temperature
± max. 2% (Full scale)
SMU 1200 Series Sensor Monitoring
Unit sold separately.
32 to 131°F (0 to 55 °C)
-4 to 185°F (-20 to 85 °C)
Max. 90%, non-condensing
≈ 25 kg
IP 54
Display/remote control/
data storage
Ambient temp. range
Storage temp. range
Relative humidity
Weight when empty
Protection class
Hydraulic Specifications
Operating mode
Pressurized operation
up to 80 bar primary pressure
Nominal operating mode Continuous operation S1 (24/7)
(INLET) -0.4 - 80 bar
Operating pressure
PIN
POUT
(OUTLET)80 bar
POUT
(LECKAGE)
0.5 bar
Total flow rate
≈ 180 ml/min
Permitted operating
10 - 3000 cSt
viscosity range
Permitted measurement
10 - 1000 cSt
viscosity range
Permitted temperature
32 to 185°F (0 to 85 °C)
range of fluid
Seal material
FPM
Ports
INLET
G1/4 as per ISO 228
OUTLET
G1/4 as per ISO 228
LEAKAGE
G1/4 as per ISO 228
Suction strainer
400 µm, metal mesh filter
Suction height
max. 0.5 m
Electrical Specifications
Connection voltages
380 V, 50 Hz, 3 Ph (-10%/+10%)
400 V, 50 Hz, 3 Ph (-15%/+10%)
415 V, 50 Hz, 3 Ph (-10%/+6%)*
440 V, 60 Hz, 3 Ph (-10%/+10%)
460 V, 60 Hz, 3 Ph (-15%/+10%)
*As per DIN EN 60204 connection voltage
must be ±10% of nominal voltage.
Connection, male
Power supply
Power consumption
B18
Supply-side
3 Ph + PE, CEE as per
IEC309
Device-side
Harting Han4A
Connection cable 10 m with main
switch, device protection and phase
sequence check
< 200 Watt
PN#02075860 / 04.15 / FSP1406-1622
CONTAMINATION MONITORS
Model Code
CSM-C 1 3 2 0 – N060 – AS - 0.
Type
CSM-C = Contamination Sensor Module - Comfort
Series
1
=
4 particle channels
Solid matter contamination coding
3
=
ISO4406:1987; NAS1638 2-5 µm, 5-15 µm, 15-25 µm, >25 µm switchable to
ISO4406:1999; SAE AS4059 (D) > 4 µm(C), > 6 µm(C), > 14 µm(C), > 21 µm(C)
Housing
2
=
for stationary use
Media
0
mineral and synthetic oils compatible with FPM seals
=
Nominal voltage
N060 =
400 V, 50 Hz, 3 Ph/460 V, 60 Hz, 3 Ph (-15%/+10%)
Integrated sensor
AS
=
Aqua Sensor - AS 1000 series
Power supply adapter
0= standard
Items Supplied:
•CSM-C
•Power supply
• Operating and maintenance instructions
• Calibration certificate
Accessories for:
Power Supply
2
3
1
1 – CEE connection plug, as per IEC309
2 - Cable, length 10 m
3 - Main switch with device protection and phase
sequence check
4 – Connection plug to the CSM-C (Harting Han4A)
6.18”
(157)
5.0”
(127)
3.82”
(97)
11.7”
(298)
3.74”
(95)
~20.2”
(~512)
4
7.36”
(187)
3.82”
(97)
5.0”
(127)
6.18”
(157)
17.9”
(455)
Dimensions
9.65”
(245)
SMU Sensor Monitoring Unit
SMU 1260-TU-00
SMU 1270-TU-00
Digital Interface
ZBE30-02 Extension cable, length 2 m
ZBE30-03 Extension cable, length 3 m
ZBE30-05 Extension cable, length 5 m
ZBE30S-10 Extension cable, length 10 m
Software
FluMoS Professional (Fluid Monitoring Software)
FluMoT (Fluid Monitoring Toolkit)
Analog Interface
ZBE48S-02 Connection cable, length 2 m
ZBE48S-05 Connection cable, length 5 m
ZBE48S-10 Connection cable, length 10 m
Hydraulic
INLET pressure hose with threaded connection
for measurement coupling type 1620, length 2m
INLET threaded coupling
OUTLET/LEAKAGE return hose, open end,
length 2m
OUTLET/LEAKAGE threaded coupling
Part No.
346 7005
370 4282
Part No.
6040851
6053924
6040852
3729098
Part No.
3141522
3355177
Part No.
6072261
6070712
6072262
Part No.
635820
629477
92649
633244
Dimensions are millimeters and for general information only, all critical dimensions should be verified by requesting a certified print.
PN#02075860 / 04.15 / FSP1406-1622