About the SV4000 Storage Vault
Congratulations on your new DIGIOP® SV4000 Storage Vault. The SV4000 Storage Vault is a high performance, high availability data storage appliance that is rack mountable and includes 12
bays for SATA 3.0/6.0 GB hard disk drives (HDDs). This appliance connects to a DIGIOP® VMS server through a SAS interface controller board (STR-CTRL) installed in the DIGIOP® server chassis.
HDDs and fan modules in the SV4000 are easily accessible for maintenance.
Installation of the SV4000 on a DIGIOP® server preconfigured at the factory with the SV4000 includes two major steps:
A.
Install HDDs into the SV4000 chassis. HDDs are shipped separately from the chassis for better protection against shock. These drives should be installed in the SV4000 chassis before startup.
B.
Connect the SV4000 to the DIGIOP® server and power up the system.
Use this hardware quick start guide together with the DIGIOP® NVR and Hybrid DVR System Setup Guide when installing DIGIOP® servers that are preconfigured at the factory with the SV4000 Storage Vault. If you
are adding the SV4000 appliance to a DIGIOP® server, or your DIGIOP® server was not preconfigured for use with this appliance, refer to the DIGIOP® SV4000 Storage Vault Hardware Installation and Setup Guide
for complete instructions on installing and configuring the SV4000 for use with your DIGIOP® server.
Unpacking the Contents
The following are included with your system. Please inspect each system component while unpacking. If any damage is noticed, please contact your provider.
•
•
•
•
•
•
•
•
•
Quick Start Guide (this document)
Surge Protection Notice
Rack installation brackets
SV4000 chassis
SASCABLE1M 1 meter SAS cable. (If a longer SAS cable is needed, please contact your distributor.)
Hard disk drives (number of drives depends on the configuration ordered)
Power cord (2)
Screws for Hard Disk Drives (HDDs)
Keys for locking HDD trays.
INSTALLATION - GENERAL GUIDELINES
Select a location where the SV4000 chassis will be installed that is compliant with the following guidelines:
•
•
•
•
•
•
•
Install the chassis in a climate-controlled environment with a temperature range of 32 °F to 95 °F (0 °C to 35 °C).
Install in a moisture-free environment with a humidity range of 20% to 80% (non-condensing).
Install in a location close enough to the DIGIOP server hardware so that the SAS cable between the two will reach. NOTE: longer cables are available from your vendor.
The SV4000 chassis can weigh between 33 lb and 55 lb, depending on the HDD configuration.
Use an Uninterrupted Power Supply (UPS).
Keep away from direct sunlight.
Install in an area with minimal dust or debris.
When installing the chassis in an equipment rack, follow the instructions provided with the rack mounting kit. When locating the chassis in the rack, provide at least 1 inch of open space above and below for
adequate ventilation.
DO_SV4000_PQ
6/3/131
© 2013 DIGIOP, Inc. All rights reserved.
Components
Bay 1, 2, 3
Bay 4, 5, 6
Bay 7, 8, 9
Bay 10, 11, 12
Handle
bracket
Chassis front view
HDD power LED:
Power on: blue
Active: blink
Alarm MUTE button
Power LED
HDD failed LED: red
Alert LED
Temperature LED
Fan LED
Front panel buttons and indicators
HDD tray with HDD
Tray latch lever
Tray latch lever release button
HDD tray in bay (unlatched)
Chassis power switch
Hot-swap blower module
Hot-swap power
supply module (2)
Serial port for console
monitoring (not used)
Chassis ground terminals
Chassis back view
2
2 x 24Gb/s mini-SAS port
Hot-swap blower module
SASCABLE1M cable
A.
Install HDDs into the SV4000 chassis
Electrostatic Discharge Warning
Electronic modules including the HDDs STR-CTRL controller board, and parts inside the DIGIOP® server chassis contains components that can be damaged by electrostatic discharge (ESD). Always follow
recommended ESD procedures when handling this board and other components inside computers. Use a grounded wrist strap and ESD approved clothing.
Each HDD is labeled for the bay it should be installed into. Drive 1 should be installed in Bay 1, Drive 2 in Bay 2, etc.
1.
Set the power switches on the back of the SV4000 chassis to “off” ( O ). There are three switches, the chassis power switch, and one switch on each power module.
2.
Starting at bay 1 and increasing sequentially, remove a drive tray from the bay for each HDD you are installing. To remove the drive tray, push in the tray lever release button, then use the tray lever to pull
the tray out of the bay.
3.
Install an HDD in each drive tray as follows:
NOTE: Use proper ESD procedures when handling HDDs.
a. Position the HDD in the drive tray with the interface connectors toward the back of the tray.
b. Align the screw holes in the sides of the HDD with the back set of holes on the sides of the tray. See the picture below.
Tray latch lever
HDD interface connectors
Screw
Align holes here
c. Secure the HDD to the drive tray with 4 screws, 2 on each side.
d. Repeat steps “a”, “b”, and “c” above for each HDD.
4.
Reinstall the drive trays in the SV4000 chassis as follows:
a. Slide the drive tray with the HDD numbered Drive 1 into Bay 1 until it is fully in place.
b. Push the tray latch lever in until it clicks and is held in place.
c. Repeat steps “a” and “b” above, installing the HDD numbered Drive 2 into Bay 2, Drive 3 into Bay 3, etc. until all HDD trays are installed.
5.
Connect power cables to the both power supply module. Plug them into a UPS (if available) with standard grounded 12 Vac grounded outlets.
NOTE
DO NOT attach the SAS cable to the SV4000 chassis or power on the SV4000 chassis at this time.
3
B.
Connecting the DIGIOP server to the SV4000 chassis
1.
Power off the DIGIOP® server.
2.
Connect one end of the SAS cable to the mini SAS port UP connector on the pack of the SV4000 chassis. Connect the other end of the SAS cable to the controller card installed in the DIGIOP server.
Controller card and cable in DIGIOP® server
3.
SV4000 SAS cable “UP” connector
Power on the SV4000 chassis as follows:
a. Set the two power module power switches to “on” (I).
b. Set the SV4000 chassis power switch to “on” (I). Wait at least 30 seconds for the SV4000 to power on and fully initialize.
4.
Power on the DIGIOP® server chassis and allow it to fully initialize.
SV4000 Storage Vault Specifications
GENERAL
ELECTRICAL & ENVIRONMENTAL
Number of Expander
Single/Dual
Universal A/C Input
100 ~ 240 Vac full range
Expander Chip
LSISAS2x28
Operating Environment
Temperature 32 ºF to 95 ºF (0 ºC to 35 ºC), Relative humidity 20% to 80%
Host Interface
Single Mini SAS 4x connector
Non-operating Environment
Expansion Interface
Single Mini SAS 4x connector
Temperature -4 ºF to 140 ºF (-20 ºC to 60 ºC), Relative humidity 10%
to 90%
Transfer Bandwidth
2,400MB/s per connector
DRIVES SUPPORTED
Drive Interface
3.0/6.0 Gb dual ported SAS, 1.5/3.0/6.0 Gb single ported SATA
Drive RPM
Up to 15,000
Form Factor
3.5”, 1” height
ADMINISTRATION / MANAGEMENT
Admin/Firmware Upgrade
In-band and Out-of-band, Serial port via Hyper terminal
LED Indicators, Audible Alarm
Yes
PHYSICAL SPECIFICATION
Dimensions (W x D x H)
19 x 18.94 x 3.50 in (482.6 x 481 x 88.8 inches: 19 x 19 x 3.5 mm)
Gross Weight (w/ PSU; w/o Rail & Disks)
33 lbs (15 kgs)
Packaging Dimension (W x D x H)
23.62 x 28.74 x 11.34 in (600 x 730 x 288 mm)
Cubic Feet
5.2
Mounting Option
Adjust plate or toolless rail (optional)
HOT-SWAP & REDUNDANCY
Disk Drive (HDD)
Front accessible HDD trays in 12 bay
Cooling
2 x hot-swap blowers
Power Supplies
500 W 1+1 hot-swap redundant 80+ (Sliver)
Power Entry
Dual AC Inlet
Copyright © 2013 DIGIOP, Inc. • Indianapolis, IN • tel: 800.968.3606 • fax: 317.663.2077 • www.digiop.com
DIGIOP is a registered trademark of DIGIOP, Inc. All rights reserved.
4
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising