Table of Contents Key functions, LED signals ......................................................................................................................... 10 PTT mode .................................................................................................................................................. 10 Service settings ......................................................................................................................................... 11 Volume control ......................................................................................................................................... 11 External connections for headset, audio player, audio recorder .............................................................. 11 Installation instructions .......................................................................................................................... 4/5 Installation intercom .............................................................................................................................. 6/7 Installation intercom with footswitch ..................................................................................................... 8/9 Installation microphone ......................................................................................................................... 7/9 Installation loudspeaker ......................................................................................................................... 7/9
PUBLIC III CE Intercom System Comfort Edition Features 









Service and Installation Instructions Open duplex Push‐to‐talk Headset interface Speech key control via footswitch Music input Recording possibility AEC (Automatic echo cancellation) NR (Noise reduction) NG (Noise gate) Individual volume control for loudspeaker / microphone/ headset / audio via +/‐ keys 
Balanced microphone inputs Technical Data Voltage/power ...................................................................................................................... 15VDC/700mA Maximum power consumption (limited by power supply) ................................................................. <15W Power consumption in OFF‐mode ................................................................................................... <0.15W Maximum output impedance (no continuous operation) at 8Ω/channel .............................................. 5W Minimum loudspeaker impedance .......................................................................................................... 8Ω Audio IN‐input level/input impedance .......................................................................... max. 100mV(1)/2kΩ REC OUT‐output level/output impedance ............................................................................. max.3V(2)/2kΩ (1)
Connect Audio IN to the headphone jack of the audio source. Tune output level of the audio source in such a way that in case of maximum volume overmodulation of the intercom system is avoided. (2)
This value depends on the volume set, on the speech volume and on the distance to the microphone. 35.054.002 03/2012 Delivery Contents Intercom System Intercom console colour RAL 7035 40.054.328 Audio cable, 2m (2x) 11.054.02 40.054.801 40.054.454 Central unit colour RAL 9010 40.054.811 40.054.453 Intercom T‐Adapter 40.054.833 Surface mounted loudspeaker 6W / 20Ω colour RAL 9010 cable outlet top/bottom 40.006.173 40.006.174 Omnidirectional microphone EM 158 in ABS housing colour RAL 9010 incl. wall/ceiling holder 40.005.094 and 25m cable with RJ45 plug 40.054.470 40.005.168
Power supply GPP10 Medical, 100‐240V ~ 50‐60Hz, 2m cable 40.054.800 Primary adapter ROW 08.052.05 Power cable EU, 2m 40.054.834 Delivery Contents Footswitch(3) Footswitch STEUTE KF 1S with 2m cable and RJ45 plug 40.054.422 Footswitch T‐Adapter 40.054.838 Patch cable KAT5e, 30cm 40.054.839 Delivery Contents Mounting Material 8x45°
16
5
Power cable USA, 2m Patch cable KAT5e, 25m 40.054.835 30
Service and Installation Instructions German and English 35.054.001 35.054.002 Mounting material for microphone ceiling fixation: drilling template, 2 screws 3,5x35mm, 2 wall plugs 5x25mm, Allen key 1,5mm. 35.054.003 40.054.827 40.054.828 Mounting material for central unit: 4 screws 3,5x35mm, 4 wall plugs 5x25mm, 4 screws 3,5x16mm, 2 hook‐and‐loop fasteners(4) 40.054.827 40.054.829 40.054.830 Mounting material for loudspeaker: 4 screws 3,5x35mm, 4 wall plugs 5x25mm, 2 screws 2,9x16mm, 2 decorative caps, cable ties 100mm. 40.054.827 40.054.831 40.054.832 Mounting material for power supply: hook‐and‐loop fastener(4). 40.054.830 C
G
Power cable UK, 2m 40.054.836 Patch cable KAT5e, 30cm 40.054.837 2x O
F
2x C
N
2x C
Patch cable KAT5e, 3m (2) 40.054.825 H
O
Patch cable KAT5e, 3m (3) 2 40.054.826 (3)
For AX the footswitch is included in the delivery of the intercom system and should be connected. For XP the footswitch can be obtained as an optional accessory. (4)
Use hook‐and‐loop fasteners only on suitable surfaces (adhesion)! 3 Positioning of the Components Microphone, Loudspeaker and Intercom Console B
4)
2)
3)
5)
>2 m
1)
4)
5)
>2 m
A
Microphone: ‐ ceiling fixation ‐ as close to the user´s working position as possible ‐ avoid collision with other components suspended from the ceiling 2)
3)
1)
A
B
2)
4 >2 m
>2 m
5)
4)
Pos. A Pos. B Pos. 1 Pos. 2 Pos. 3 Pos. 4 Pos. 5 1)
3)
2)
1)
Intercom Console: ‐ the intercom console has to be placed as far from the control room door as possible 1)
1)
Loudspeaker: ‐ the loudspeaker must not be installed in the hatched area (pos. 1) to avoid interferences ‐ preferably the loudspeaker has to be installed on the wall ‐ installation height >2m ‐ avoid loudspeaker radiation towards the control room door ‐ distance microphone / loudspeaker >2m the greater the distance, the better the transmission quality 4)
5)
3)
Wall fixation of the loudspeaker Ceiling fixation of the loudspeaker Prohibited fixation area for the loudspeaker Wall fixation of the microphone Privileged fixation area of the loudspeaker Optional fixation area of the loudspeaker Intercom console in the control room 5 1 > Intercom Central Unit (DC Power) 2a > Intercom Central Unit (2) < Intercom Console (2) 1a > Intercom Cleaner Socket < Intercom Power Supply 2b 1b > Intercom Power Supply < Intercom Cleaner Socket 3a > Intercom Central Unit (3) < Intercom T‐Adapter (2) 7b > Intercom Speaker < Intercom T‐Adapter (3) > Intercom Console (2) < Intercom Central Unit (2) 6b > Intercom T‐Adapter (2) < Intercom Central Unit (3) 8 > Intercom T‐Adapter (1) > Intercom Central Unit (1) < Intercom Console (1) 7a > Intercom T‐Adapter (3) < Intercom Speaker No other power supply than the one tested and appro‐
ved by Clarson must be used.
1b 3b > Intercom Console (1) < Intercom Central Unit (1) 6a 3b 2b 1a Control Room Intercom System without footswitch Installation Loudspeaker Patient´s Room C
Important for Installation Planning: Dimensions microphone cable : Ø 2,6mm Length 25m Clearance hole for RJ45 plug at least Ø16mm. Observe drilling template! 1 3a 2a 6a N
Wandsteckdose wall socket 100‐240V ~ 50‐60Hz 7b 2m 3m 25m 3m Dimensions loudspeaker cable: Ø 5,8mm Length 25m Clearance hole for RJ45 plug at least Ø17mm. Dimensions mounting material see page 3 Ceiling Installation Microphone 30cm Installation Central Unit H
C
25m C
G
6b On the wall or under the table 8x45°
Use hook‐and‐loop fasteners only on suitable surface (adhesion)! 5
7a O
16
8 O
or
30
C
6
C
F
drilling templeate 7
1 > Intercom Central Unit (DC Power) 2a > Intercom Central Unit (2) < Intercom Console (2) 3b > Intercom Console (1) < Intercom Central Unit (1) 5 > Footswitch T‐Adapter (3) 7a > Intercom T‐Adapter (3) < Intercom Speaker 1a > Intercom Cleaner Socket < Intercom Power Supply 2b > Intercom Console (2) < Intercom Central Unit (2) 4a > Intercom Central Unit (3) < Footswitch T‐Adapter (2) 6a > Footswitch T‐Adapter (1) < Intercom T‐Adapter (2) 7b > Intercom Speaker < Intercom T‐Adapter (3) 1b > Intercom Power Supply < Intercom Cleaner Socket 3a > Intercom Central Unit (1) < Intercom Console (1) 4b > Footswitch T‐Adapter (2) < Intercom Central Unit (3) 6b > Intercom T‐Adapter (2) < Footswitch T‐Adapter (1) 8 > Intercom T‐Adapter (1) 1b No other power supply than the one tested and appro‐
ved by Clarson must be used.
3b Control Room Intercom system with footswitch 2b 1a Installation Loudspeaker Patient´s Room C
Important for Installation Planning: Dimensions microphone cable : Ø 2,6mm Length 25m Clearance hole for RJ45 plug at least Ø16mm. Observe drilling template! 3a 2a 4a 1 N
wall socket 100‐240V ~ 50‐60Hz 7b 2m 3m 25m 3m 2m Dimensions loudspeaker cable: Ø 5,8mm Length 25m Clearance hole for RJ45 plug at least Ø17mm. Dimensions mounting material see page 3. Ceiling Installation Microphone 30cm Installation Central Unit H
C
25m C
G
5 4b On the wall or under the table 8x45°
Use hook‐and‐loop fasteners only on suitable surface (adhesion)! 16
5
6a 30cm O
O
8 or
30
C
8 C
drilling template 6b F
7a 9 External Connections Central Unit Key Functions, External Connections and LED Signalling Connection for audio recorder(5) External Connections Intercom Console Central Unit Key Intercom Console Connection for audio player(5) Connection for headset(5) After switching on the intercom system the intercom console is activated, regardless of whether the headset microphone is plugged in or not. Switchover to headset operation is made by removing and re‐inserting the headset microphone plug (wait approx. 2 sec). Function LED State System Operating Status Intercom System ON/OFF on ready for use Operational Start‐up/Service(6) off switched off Changing to Set‐up Mode: flashes set‐up mode Loudspeaker ON/OFF on loudspeaker ON Push and hold key and plug in power supply again. off loudspeaker OFF Continue to push key (approx. 5 sec) until LED above the key flashes. Microphone ON/OFF on microphone ON In set‐up mode the intercom system´s maximum volume for and set by the user can be limited off microphone OFF to a feedback‐free value, even under unfavourable conditions (for example an open access door). Audio IN ON/OFF on Audio IN ON Setting Maximum Volume: off Audio IN OFF When changing to set‐up mode the volume just set for and is set and saved as maximum value Increase volume led brightens for the user. flashes maximum volume Reduce volume led darkens flashes minimum volume 1 1a Unplug power supply (connector or ). Push key to leave set‐up mode. Or push key in set‐up mode to set volumes for and to maximum value. Simultaneously push and hold and keys (approx. 5 sec) to save these values until LEDs The corresponding LEDs indicate the operating state of the intercom system. Should external disturban‐
ces such as prolonged voltage drops change the operating status, the original state can be restored via control panel. above these keys are flashing. The volume can only be changed if either or or is switched on. PTT Mode: Push and hold key to switch the microphone on. Switching on PTT Mode: Switch the intercom system off Push and hold key (approx. 5 sec.) until LED above flashes. Switching off PTT Mode: Switch the intercom system off Push and hold key (approx. 5 sec) until LED above flashes. Simultaneously push and hold and keys (approx. 5 sec) to save these values until LED Now push and keys to set the intercom system´s maximum values for and required by the user. above these keys are flashing. Push key to leave set‐up mode. Trouble‐Shooting: In case of interferences the position of the intercom components should be modified to increase the distance to sources of strong electromagnetic radiation. (5)
Not included in scope of supply (6)
Unplug or plug in patch cable only in power‐free state
10 11 