Safety Instructions
Table of Contents
Safety Instructions & Warnings
What’s Included
Orbit IC Fixture Installation
Cable Connections
Remote & Controller Overview
Controller Programming
Warranty & Safety Warnings
1
2
3
4
5
7
12
Thank You!
For purchasing our Orbit IC LED.
Please read all instructions before
getting in the LOOP!
Safety Instructions & Warnings
IMPORTANT: Please refer to additional safety warnings on last page.
- Carefully examine light fixture, wires and all components before and after installation. Ensure there is no
damage or water on any components BEFORE plugging into a GFCI wall outlet.
- NEVER plug in a wet cord. Always unplug with dry hands for any maintenance or service.
- Ensure 12VDC UL® transformer is plugged into a GFCI approved outlet with a drip loop for each light
fixture. If using eFlux wave or flow pumps, ensure a 24VDC UL ® transformer is used with drip loop.
- Turn controller OFF and disconnect lights and pumps from power & GFCI outlet before performing service.
- Never look directly into the LEDs.
- Never run pumps dry or out of water.
- Follow all safety instructions for any eFlux wave or flow pumps or additional accessory add-ons.
- eFlux wave pumps create a tremendous amount of water flow. Do not install pump where the
strong current can harm corals or animals.
- eFlux wave pumps can produce powerful waves in both wave and surge modes. Ensure your aquarium is
designed for wave pumps and ensure pumps are mounted low enough not to push water out of the
aquarium tank.
- Ensure light fixture is kept clean of any saltwater or salt creep. Fixture is IP65 rated for water splashing
but must be kept clean of water, moisture, salt creep and/or any mineral deposits.
Orbit IC LED
Use caution when
installing magnets
Ensure pump location
will not spill water from
wave motion
Keep fixture clean of
water and/or salt creep
eFlux Accessory
Wave Pump Add-on
Use only with GFCI
Protected AC Outlet
Ensure correct voltage power
supply for each component
AC Power
24VDC
Power Supply
12VDC
Power Supply
P3
P2
P1
Ensure use of drip
loop for all cables
L2
L1
LOOP IC Light
Manifold HUB
12V DC ONLY
Drip
Loop
Wave Pump
Manifold HUB
24VDC ONLY
Drip
Loop
LOOP
Controller
SAVE THESE INSTRUCTIONS
Page 1
GFCI Outlet
Ensure use of drip
loop for all cables
Orbit™IC LED Light
Additional Help
For additional installation & operating instructions and videos, visit our website at www.current-usa.com
What’s Included
Each Orbit IC LED lighting system includes:
Item
A
B
C
D
E
F
G
H
J
L
Description
Quantity
Orbit IC LED Light Fixture
1
Adjustable Docking Mounts (pre-installed)
2
12V DC Transformer, UL® Listed
1
Light HUB Manifold w/4 Silicone Covers
1
Light HUB Mounting Bracket w/2 Screws
1
LOOP LED Light & Pump Controller
1
LOOP Controller Bracket w/2 Screws
1
Orbit IC Wireless Remote Control
1
IR Infrared Sensor
1
Cable Wraps
3
Note:
If your Orbit IC LED is missing any
components, please contact us
directly at www.current-usa.com.
DO NOT RETURN TO RETAILER
A
C
B
or
D
!"#
$%&$'
&+
#)*"
&((
#)*"
,"/#7"-
7&0-
*)+0#"
<
:
;
="+#"-"!0*"
*
L2
L1
F
E
G
2
3
STREAM
SURGE
WAVE
WAVE
P/S
P/S
FREQ
FLOW
FLOW
L
FEED
!"
CLEAN
1
FREQ
H
J
Optional Accessories
Accessory Wave Pumps
#1685 EFlux Wave Pump Manifold
(connects up to 3 wave pumps)
#6004 Accessory Wave Pump 660 GPH
#6005 Accessory Wave Pump 1050 GPH
#6006 Accessory Wave Pump 2100 GPH
Controllable DC Flow Pumps
#6009 EFlux DC Flow Pump 1050 GPH
#6010 EFlux DC Flow Pump 1900 GPH
#6011 EFlux DC Flow Pump 3170 GPH
Page 2
Orbit IC Accessories
#4193 Orbit Adjustable Tank Mount
#4197 LOOP Controller Hinge Mount System
#5076 12VDC 72W Transformer
Installation Instructions
Orbit IC LED Light Fixture Installation
Fixture Installation
Step 1. Unpack light fixture and components. Remove any plastic film on light fixture (A).
Step 2. Slide the adjustable docking legs (B) on the side of the light fixture (A) to match the length of
your aquarium. (Refer to Orbit Adjustable Tank Mounting Bracket or Orbit Hanging Kit instructions if
using those instead of sliding docking mounts.)
Step 3. Set fixture on aquarium and ensure docking legs fit snug on edges of aquarium.
INSTALLING LOOP IC CONTROLLER AND IC LIGHT MANIFOLD HUB
Step 4. Choose a location underneath your aquarium cabinet free of excessive moisture and/or
saltwater creep. Note: If you want the LOOP IC Controller (F) outside cabinet, ensure the mounting
location is 8-12” away from where the IC Light Manifold HUB (D) will be mounted.
Step 5. Using included wood mounting screws, mount the IC Light Manifold HUB mounting bracket
(E) and LOOP IC Controller bracket (G) to stand. Slide IC Light Manifold HUB (D) and LOOP IC
Controller (F) into each bracket.
D
F
Manifold HUB
LOOP Controller
Wood
Screws
Wood
Screws
IC Light Manifold
HUB Mounting Bracket
L1
L2
LOOP IC Controller
Mounting Bracket
G
Store Cap
Step 6. Remove silicone caps from L1 light #1 DC input and
L1 light #1 connection. Attach caps to IC Light HUB mounting
bracket (E) for safe storage (see diagram on right.)
Keep other silicone caps in place if not in use.
Remove
Cap
L2
L1
Store Cap
J
Step 7. (Optional) An IR receiving sensor is located on the front of the LOOP IC Controller. The IR
sensor is what receives control and on-demand command signals from the wireless remote. If you
mount your LOOP IC Controller under your stand, an additional remote IR sensor (J) is included. To
mount sensor, unwrap cable and attach the IR sensor to your stand using the stick tape. Ensure
cable can reach IC light manifold HUB (D).
IR Sensor
IR
E
D IC LIGHT
CABLE CONNECTIONS
Important:
Before connecting all components
together, please review the following
specifications in regards to the IC
Light Manifold HUB (D).
Light #2 Power
DC Input
Manifold HUB
Light #1
Power DC Input
Light #2
Connection
Light #1
Light Connection
L2
L1
Communication
Indicator LED
Port#4
Port#1
Port#3
Port#2
Micro USB Ports
Page 3
Specifications:
Light DC Inputs:
Voltage: 12VDC
Max. DC Input per channel: 72w@12VDC
Max. DC Output per channel: 60w@12VDC
Light Connections:
L1 = Light #1
L2 = Light #2
Micro USB Ports:
Port#1= LOOP IC Controller
Port#2= Communications
Port#3= Communications
Port#4= Communications
Orbit™IC LED Light
Cable Connections
Step 8. Connect cables in the following order:
A
a. Connect LOOP Controller microUSB cable into Port#1 on bottom of IC Light Manifold HUB
b. Connect IR Sensor micro USB cable into Port#2 on bottom of IC Light Manifold HUB (optional)*
B
c. Connect Orbit IC LED light into L1 Light Connection on front of IC Light Manifold HUB
C
d.
D Connect 12V DC transformer cable into L1 Light Power DC input on front of IC Light Manifold HUB
12VDC Transformer will have
a black O-Ring on cord
12VDC
Transformer
D
IC Light
Manifold HUB
AC Power
GFCI Outlet
C
Orbit IC LED Light
Page 3
L1
Port#1
A
Port#2
!"
IR Infrared
Sensor B
LOOP Controller
* NOTE: The LOOP Controller has an integrated IR sensor on the front display. If mounting the controller outside your cabinet,
the use of the IR Infrared Sensor B is not required. If you wish to mount the LOOP controller inside your cabinet, the remote
IR sensor can be mounted in a discrete location outside your stand.
Step 9. Plug 12V DC transformer into GFCI outlet. Communication LED indicator light on IC light manifold
HUB will turn BLUE.
Main Power
Step 10. Use velcro cable wraps (L) to safely store excess cables.
Step 11. Remove clear plastic tab from battery
compartment on Orbit IC remote control (H).
L2
Step 12. Press Main Power key to turn Orbit IC LED light ON.
Step 13.Follow programming steps on the following pages to
set the LOOP IC Controller clock and begin operation.
Remove Battery Tab
Page 4
Installation Instructions
LOOP IC Remote Control Overview
Light Power ON/OFF - press to turn light fixture and Main IC Controller on or off
SET
CLOCK
ON
TIME
OFF
TIME
%
WEATHER
%
%
HOUR
+
MINUTE
-
SET
CLOCK
ENTER
RESUME
M
ON
TIME
ON TIME - press to program time light should begin to turn on each day
OFF
TIME
OFF TIME - press to program time light should begin to turn off each day
HOUR
HOUR / + - press to change the Hours or adjust weather forecast % up (+)
+
MINUTE
_
CLEAN
Set Time of Day - press to set the 24:00 clock/current time of day
FEED
MINUTE / - - press to change the Minutes or adjust weather forecast % down (-)
ENTER/RESUME- press to enter a setting or to re-enter back into normal program
DAYLIGHT- press to program color spectrum to run during the Day
1
3
2
Sunrise/Sunset - press to program color spectrum to run during sunrise/sunset
STREAM
SURGE
WAVE
P/S
FREQ
FLOW
M
TM
current-usa.com
Moonlight - press to program color spectrum to run during the night
FREQ
FLOW
LOCK
WEATHER
Memory - press to program a custom color spectrum (Color Memory)
current-usa.com
Weather - press to program
the daily weather forecast or turn off active weather
%
LOCK
Lock/Unlock - press to lock settings and all remote functions, press again for 5
seconds to unlock settings and remote functions
Color Spectrum Adjustment
Water Pumps Programming
1
2
3
P/S
RGBW Adjustment - press
to adjust Red / Green / Blue /
White color spectrums
0-100%
Pump 1 - press to program the primary eFlux wave
pump
Pump 2 - press to program secondary eFlux wave
pump #2
Pump 3 - press to program pump #3. NOTE: PUMP#3
is only programmable in STREAM mode (no wave mode)
Primary/Secondary- press to designate if Pump 2 is a
Primary pump or Secondary (slave to Pump#1)
Dynamic Modes
FEED
Pump Power ON/OFF - press to all pumps ON or OFF
STREAM
SURGE
WAVE
LUNAR - press to run light lunar mode:
Blue: 100%, White:0%, Red: 0%, Green: 0%
Stream Mode - press to program designated pump into
stream/constant flow mode
Surge Mode - press to program designated pump into
surging (long on/off) flow mode
Wave Mode - press to program designated pump into
wave (short pulsing) flow mode
Feed Mode - runs feed program, 10 min duration
Lights: Remaining in current color mode
Pumps 1 & 2: reduce flow to 0%
Pump 3: reduce flow to 0%
Note: Any EFlux DC Flow Pumps connected to
network reduce flow to 30%
Lunar Cloud - press to run night cloud cover
(blue moonlight fades)
CLEAN
Clean Mode - runs clean mode: Duration 30
min, White:100%, Red:100%, Green:100%,
Flow Increase - press to increase the flow rate/impeller
speed of pump from 0-100%
Rolling Clouds - runs rolling cloud program
FLOW
Flow Decrease - press to decrease the flow rate/impeller speed of pump from 0-100%
Random Clouds - runs random cloud program
FREQ
Frequency Increase - increases frequency / time
interval: Surge/Wave
Lightning - runs lightning storm program
Frequency Decrease - decreases frequency / time
interval: Surge/Wave
Full Thunderstorm - runs full thunderstorm
program
FLOW
FREQ
Page 5
Orbit™IC LED Light
LOOP IC Controller Overview
LOCK Mode
Designates if LOOP IC Controller
and wireless IR remote are locked
Color Adjustment
or unlocked
B=Blue
ON Time
Pump Indicator
CLOCK
W=White (Indicates controller OFF Time
Displays which eFlux pump is
R=Red
is in Timer Mode) (OFF Time also displays
currently working or being
G=Green
when lights are OFF)
programmed
W=White & also
indicates active
weather mode
FLOW %
MAIN
Main indicator/
time display
Frequency
Seconds S
Full Moon
CLEAN FEED
Fading Moon
Rolling Cloud Random Cloud
Note:
Clean Mode Feed Mode
Lightning Storm Full Storm w/Lightning
LOOP IC Controller backlit display is designed to shut off after 30 seconds.
Weather Adjustment
MODE
0-50%
Displays level of
FLOW or FREQUENCY
Light Cycle Overview
Please review the following light cycle diagram:
WEATHER
%
(Adjustable)
Daylight
& Weather Program
(Adjustable)
(Adjustable - same color
spectrum as Sunrise)
Sunrise
Sunset
(Adjustable)
Light Off
Moonlight 6 Hrs.
15m
60m
15m
15m
60m
Light Off
15m
Time
OFF
TIME
ON
TIME
(Adjustable)
(Adjustable)
Default Settings - The following settings are pre-programmed into the controller:
Daylight Color Spectrum - W:90% B:100% R:100% G:100%
ON Time: 07:00
Sunrise/Sunset Color Spectrum - W:5% B:70% R:45% G:20%
OFF Time: 18:00
Moonlight Color Spectrum - W:0% B:10% R:0% G:0%
Pumps: Stream @100% Flow
WEATHER: OFF (Rolling Cloud 30%) Custom Light Color (M): - W:50% B:100% R:100% G:30%
Page 6
Installation Instructions
LOOP IC Controller Programming
Indicates light is off
Turning Lights ON/OFF
Press the Main On/Off key
to turn Orbit IC lights on or off. When off, display
will read “OFF.” The LOOP IC Controller will remain on and the backlit display will
shut off after 30 seconds.
Note: Turning the Orbit IC LED lights off will not turn the wave pumps off. Pumps
will continue to run at their programmed setting. Pumps must be turned on/off
separately than IC lights using the pump Main On/Off
key. When pumps are
off, display will read “OFF”,
LOCK & UNLOCK Settings
The integrated LOCK/UNLOCK feature is designed to ensure other IR signals (e.g. TV remote) do not change
the settings on your LOOP IC Controller.
To lock all settings in the LOOP IC controller, simply press LOCK
for 5 seconds. “LOC1” will appear on screen along with lock icon.
LOCK
To unlock and allow the wireless remote control to operate again, press LOCK
for 5 seconds. “LOCO” will appear on screen and lock icon will disappear.
LOCK
Programming Settings
Setting Current Time of Day
Press SET CLOCK
SET
CLOCK
the CLOCK icon will appear and main digits will blink.
Press HOUR +
and MINUTEto adjust the clock to the current time of day.
Hours and Minutes will change on the main digits of the display as keys are pressed.
HOUR
MINUTE
_
+
Press ENTER/RESUME to save. The LOOP IC controller will now run the programmed
lighting cycle.
Note: LOOP IC Controller uses military time from 00:00 to 24:00. For example,
9:00pm=21:00 hours. On/off times can only be set between the same 00:00 and
24:00 hours.
Setting Daily ON/OFF Times
Press ON TIME key
ON
TIME
the ON icon will appear on the display and main digits will blink.
Press HOUR+
and MINUTEENTER/RESUME to save.
HOUR
+
Press OFF TIME key
Press HOUR+
HOUR
+
OFF
TIME
MINUTE
_
to adjust the clock to the desire ON time. Press
the OFF icon will appear on the display and main digits will blink.
and MINUTE-
MINUTE
_
At any time press ENTER/RESUME
to adjust the clock to the desire OFF time.
ENTER
RESUME
to save.
Page 7
Main Digits Blink
Orbit™IC LED Light
LOOP IC Controller Programming
Programming Daily Weather
To Turn Daily Weather Program On/Off
Press Weather % key
on wireless remote and hold for 5 seconds. “W”
will appear on the LOOP IC Controller screen and the current weather program icon
will be displayed on the bottom of the screen and will display during weather cycle.
3&4')&+
2
Press Weather % key again
on wireless remote and hold for 5 seconds to
turn the weather program off. “W” will disappear from display and your LED light
will run its normal photoperiod with no weather patterns.
3&4')&+
2
To Program Daily Weather
Press Weather % key
, “SET” will display on LOOP IC Controller screen.
Choose any of the four weather patterns - Rolling Clouds
, Random Clouds
Storm
, Full Storm
and press to designate as a weather pattern.
3&4')&+
2
Press the Hour +
)"*+
/
and Minute - - keys to change the daily weather forecast % between 10% and 50%.
,-.*'&
Press Enter/Resume
, the weather program is now programmed and will run automatically throughout the
Daylight lighting period based on your weather forecast. (example: Rolling Clouds @ 20% with a 9 hour
daylight period, cloud cover program will run 6 times throughout the day for 108 total minutes (18 minutes
each time.)
&.'&+
+&%*,&
Programming Color Spectrums
The LOOP IC Controller allows you to program & change the color spectrum
for DAYLIGHT, SUNRISE/SUNSET, MOONLIGHT and a CUSTOM color. The
color spectrum can be adjusted by changing the intensities of Red, Green, Blue
& White (RGBW) and using the designated color arrow keys on the wireless remote.
The LOOP IC Controller will display R, G, B, W and the level of each color.
Color Adjustment - Press to
adjust Red/Green/Blue/White
color spectrums 0-100%
To Program DAYLIGHT
Press DAYLIGHT key
on wireless remote and “L1” will display on the LOOP
IC Controller screen. Use the RGBW keys to change the % intensity. Once the
desired color spectrum is achieved, Press and hold the DAYLIGHT key
for
5 seconds. The LOOP IC Controller will display “E1” indicating spectrum is saved.
To Program SUNRISE/SUNSET
Press SUNRISE/SUNSET key
on wireless remote and “L2” will display on the LOOP
IC Controller screen. Use the RGBW keys to change the % intensity. Once the
desired color spectrum is achieved, Press and hold the SUNRISE/SUNSET key
for 5 seconds. The LOOP IC Controller will display “E2” indicating spectrum is saved.
To Program MOONLIGHT
Press MOONLIGHT key
on wireless remote and “L3” will display on the LOOP
IC Controller screen. Use the RGBW keys to change the % intensity. Once the
desired color spectrum is achieved, Press and hold the MOONLIGHT key
for 5 seconds. The LOOP IC Controller will display “E3” indicating spectrum is saved.
***NOTE: YOU MUST press ENTER/RESUME
&.'&+
+&%*,&
to put the LOOP IC Controller back into timer mode after programming***
Page 8
Installation Instructions
LOOP IC Controller Programming
To Program a CUSTOM Color Spectrum
Press CUSTOM key M on wireless remote and “L4” will display on the LOOP
IC Controller screen. Use the RGBW keys to change the % intensity. Once the
desired color spectrum is achieved, Press and hold the CUSTOM key M
for 5 seconds. The LOOP IC Controller will display “E4” indicating spectrum is saved.
On Demand Dynamic Modes
Moonlight Modes
Press either Full Moon
or Fading Moon
on IC wireless
remote to activate on-demand moonlight. Program will run 30
minutes then resume into normal programming.
To exit on-demand program, press
on wireless remote.
ENTER
RESUME
Weather Modes
Press either Rolling Cloud
,Random Cloud
, Lightning
Storm
, or Full Storm with Lightning
on wireless remote
to activate on-demand weather. Program will run 30 minutes,
then resume into normal timer programming.
To exit On-Demand program, press
.
On-demand icon moonlight or
weather icon will display on screen
ENTER
RESUME
CLEAN Mode
Press CLEAN
on wireless remote activate a color spectrum
for cleaning the aquarium. Program will run for 30 minutes, then resume
into normal timer programming.
CLEAN
To exit on-demand programs at any time, press
ENTER
RESUME
.
eFlux Wave Pump Programming
Turning Pumps On/Off
Press the Main On/Off key
on wireless remote to turn all of the wave pumps
on or off. When turning off, “OFF” will be display on the LOOP IC Controller and
each pump icon will be followed by “---”.
Turning Individual Wave Pumps On/Off
To individually turn each wave pump on or off, simply hold the designated pump
key
for 5 seconds. The individual pump will turn on/off, if off the pump
icon will display “OFF” on the LOOP IC Controller.
,
-
.
FEED Mode
To set all wave pumps into feed mode, press the FEED Mode key
. All eFlux
wave pumps (1,2,3) within the LOOP network will stop flowing for 10 minutes and
“FEED” will appear on the LOOP IC Controller. After 10 minutes, wave pumps will
ramp back into their previous programmed flow setting.
FEED
NOTE: Any eFlux DC Flow Pumps within the LOOP network network will ramp down to a 30% flow speed
for 10 minutes. After 10 minutes, pumps will ramp back into their previous programmed flow setting.
**Note: Any on-demand Mode, CLEAN mode or FEED mode can be exited at any time by pressing
Page 9
ENTER
RESUME
Orbit™IC LED Light
LOOP IC Controller Programming
eFlux Wave Pump Programming
Designating Wave Pumps for Programming
Press the wave pump key
on the wireless remote you
are choosing to program, the designated pump icon on the LOOP IC Controller
will flash and show its current flow program.
!
"
#
Operational Flow Modes
There are three modes of water flow available for Pumps 1 and 2; Stream/Steady, Surge/Gyre and
Wave/Pulse. Note that Pump 3 is designated as a circulation pump and can only be programmed in
Stream/Steady Flow Mode.
STREAM/STEADY MODE
When a pump is in Stream/Steady mode, the pump will constantly circulate
water at the programmed speed.
100%
Flow rate is adjustable from
0-100% in 10% increments by
pressing:
FLOW
Flow
50%
FLOW
0
SURGE/GYRE MODE
Flow rate is adjustable from
0-100% in 10% increments by
pressing:
FLOW
TIME
When a pump is in Surge/Gyre mode, the pump will gently ramp up and down
to the maximum flow speed based on the frequency (time) programmed. This
mode mimics back and forth water surges found in the ocean. See GYRE for
using 2 pumps and creating Gyre flow.
100%
FLOW
Max. Flow
ON
FLOW
50%
Frequency (timer duration) is adjustable:
FREQ
FREQ
Press to decrease time duration
of pulse and increase wave motion
Press to increase time duration
of pulse and decrease wave motion
WAVE/PULSE MODE
Flow rate is adjustable from
0-100% in 10% increments by
pressing:
FLOW
FLOW
OFF
0
FREQUENCY
FREQUENCY (seconds)
When a pump is in Wave/Pulse mode, the pump will turn on/off, creating a
pulsing between the maximum flow and off. This flow simulates waves
commonly found on reef crests.
Max. Flow
100%
ON
FLOW
50%
Frequency (timer duration) is adjustable:
FREQ
FREQ
Press to decrease time duration
of pulse and increase wave motion
Press to increase time duration
of pulse and decrease wave motion
10s 15s 20s 25s 30s 40s 50s 70s 80s 90s
OFF
0
TIME
FREQUENCY(seconds)
.3s
.3s
Pump OFF .3s
Pump ON
.5s .7s 1s
.5s .7s
.5s .7s
Page 10
2s 3s
1s
2s
3s
1s
2s
3s
4s
5s 6s
5s
6s
7s
4s
4s
5s
6s
7s
7s
Installation Instructions
LOOP IC Controller Programming
Program Flow Mode
WAVE
Press the FLOW mode key
you wish to run the pump
in on the remote. The LOOP IC Controller display will show as follows:
SURGE
STREAM
P=Pump
1,2,3=indicates the pump being programmed
P=Wave/Pulse Mode
L=Stream Mode
S=Surge Mode
For example:
P1-S = Pump #1 Surge Mode
P2-L = Pump #2 Stream Mode
Program Water Flow
Press the increase & decrease flow keys
to adjust the pumps
maximum flow rate until the desired flow is reached. Flow rate (between
0-100%) will display on the LOOP IC Controller.
FLOW
FLOW
Program Frequency Setting
If programming the eFlux wave pump in either wave or surge mode, adjust
the frequency setting by pressing the increase & decrease frequency keys
until the desired time duration is reached and displayed on the LOOP IC Controller.
FREQ
FREQ
The frequency will display on the LOOP IC Controller in seconds.
NOTE: Decreasing frequency increases the time duration between min/max flow.
It will appear opposite on the LOOP IC Controller (decreasing frequency will increase the time duration and
decrease wave motion.)
Your setting will be automatically be saved into memory after 10 seconds. No keys need to be selected to
save settings. You can also press Enter/Resume
at any time to save settings and go to timer program.
ENTER
RESUME
Designating Primary/Secondary Pump
The LOOP IC Controller can run two pumps in opposite flows to create Gyre flow in an aquarium. Pump #1 is
the primary wave pump, Pump #2 can be a primary or secondary pump. When pump #2 is designated a
secondary wave pump, it will run the opposite Wave/Pulse or Surge mode as Pump #1.
To program Pump #2 as a secondary wave pump, press the P/S key and hold for 5 seconds. The LOOP
IC controller will display 2-SL when working as a secondary pump. Press P/S key P/S for 5 seconds to go
back to Pump #2 as a primary pump, LOOP IC controller will display 2-P when running in primary pump mode.
Reset LOOP IC Controller to Default Settings
If you wish to reset your LOOP IC Controller back to the factory default
settings, press the Main Power key
and hold for 10 seconds. All
settings in LOOP IC controller will default back and display will read “-ini”.
Page 11
Orbit™IC LED Light
Cable Connections
GFCI Outlet
P3
P2
P1
Drip
Loop
Drip Loop
Current-USA One Year Limited Warranty
This product MUST be purchased from an authorized Current-USA
reseller. Visit our website for a list of unauthorized resellers.
Current USA, Inc. warrants this product against defects in
materials and worksmanship for ONE (1) YEAR from the date of
original retail purchase and is none transferable.
Do not install pumps where strong currents can harm animals. Do
not install close to sand bed where it can suck/stir sand.
Pumps can produce powerful wave action in both wave and surge
modes. Ensure your aquarium is designed for wave pumps and
ensure pumps are mounted low enough not to push water out of
the aquarium tank.
Magnet assembly is VERY powerful. Be cautious not to cause
injury to fingers.
Keep magnets and all accessories out of reach of children.
Never place magnets or pump near sensitive electronics, sharp
objects or other attractive surfaces.
Do not run pumps dry or out of water.
Always place spacer between magnets when not in use.
Always unplug with dry hands for maintenance or servicing.
Turn all controllers OFF and disconnect power supply before
performing any service or maintenance.
This product MUST be powered by a UL or ETL listed power supply.
To avoid possible electric shock, power supply MUST be plugged
into a GFCI wall outlet installed by a certified electrician in
accordance with all local codes. All products must have a drip loop.