Conductor network - Bailey International

Conductor network - Bailey International
Conductor network
Swing lid DC tape clip
Conductor
size
Weight
each
Part
No.
25 x 3 mm
0.07 kg
CP210-H†
25 x 6 mm
0.08 kg
CP220-H†
25 x 3 mm
0.03 kg
CP110-H
25 x 6 mm
0.04 kg
CP120-H
For use with bare copper
For use with bare aluminium
CP210-H
DC tape clips manufactured from high quality copper and aluminium alloys
for excellent corrosion resistance and high pull off loads.
IEC/BS EN 62561-4 (CP210-H, CP110-H)
†
UL96 (CP210-H, CP220-H)
Fix using countersunk wood screws 11⁄2” No. 10 or M6 (Part no.
SW005 or SW105) and wall plugs (Part no. PS305) - see Accessories
page 72.
Adjustable DC tape clip
Conductor
size
Weight
each
Part
No.
31 x 3 mm and 31 x 6 mm
0.12 kg
CP230-H
38 x 3 mm, 38 x 6 mm and 40 x 6 mm
0.14 kg
CP240-H
50 x 3 mm and 50 x 6 mm
0.16 kg
CP260-H†
For use with bare copper
CP260-H
DC tape clips manufactured from high quality copper alloy for excellent
corrosion resistance and high pull off loads. Variable thicknesses of
conductor are accommodated by a reversible lid.
†
UL96 (CP260-H)
Fix using countersunk wood screws 11⁄2” No. 10 or M6 (Part no.
SW005 or SW105) and wall plugs (Part no. PS305) - see Accessories
page 72.
51
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
DC tape clip
Conductor
size
Weight
each
Part
No.
20 x 3 mm
0.06 kg
CP205
25 x 4 mm
0.07 kg
CP216
30 x 5 mm
0.10 kg
CP227
38 x 5 mm
0.12 kg
CP245
40 x 4 mm
0.14 kg
CP241
50 x 4 mm
0.15 kg
CP256
25 x 3 mm
0.10 kg
CP215
25 x 6 mm
0.13 kg
CP225
50 x 6 mm
0.26 kg
CP265
0.20 kg
CP305
For use with bare copper
CP205
For use with PVC covered copper
For use with lead covered copper
25 x 3 mm
For use with bare aluminium
20 x 3 mm
0.02 kg
CP105
50 x 6 mm
0.05 kg
CP125
25 x 3 mm
0.04 kg
CP115
50 x 6 mm
0.06 kg
CP130
For use with PVC covered aluminium
Manufactured from high quality copper or aluminium alloys.
IEC/BS EN 62561-4 (CP215, CP115)
Fix using countersunk wood screws 11⁄2” No. 10 or M6 (Part no.
SW005 or SW105) and wall plugs (Part no. PS305) - see Accessories
page 72.
Tape clip
Conductor
size
Weight
each
Part
No.
20 x 3 mm
0.02 kg
CP510
25 x 3 mm
0.02 kg
CP515
20 x 3 mm
0.01 kg
CP405
25 x 3 mm
0.01 kg
CP410
25 x 6 mm
0.01 kg
CP415
0.02 kg
CP517
For use with bare copper
For use with bare aluminium
CP515
NEW
For use with PVC covered tape
25 x 3 mm
Manufactured from pure copper or aluminium, these pressed clips are
available in a range of sizes to suit bare and PVC covered copper and
aluminium tapes.
52
Fix using roundhead wood screws 11⁄2” No. 10 or M6 (Part no.
SW305 or SW405 and wall plugs (Part no. PS305) - see Accessories
page 72.
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
One hole cable clip
Conductor
diameter
Conductor
material
Weight
each
Part
No.
For use with solid circular conductor
8 mm
Copper
0.01 kg
CP905
8 mm
Aluminium
0.01 kg
CP925
10 mm*
Copper
0.01 kg
CP915
10 mm*
Aluminium
0.01 kg
CP935
50 mm2
Copper
0.01 kg
CP910
70 mm2
Copper
0.01 kg
CP915
95 mm2
Copper
0.01 kg
CP920
CP915
For use with stranded conductor
* PVC covered 8 mm conductor.
Manufactured from pure copper or aluminium, these pressed clips are
available to suit bare and PVC covered copper and aluminium solid circular
conductor, and bare copper stranded conductor.
Fix using roundhead wood screws 11⁄2” No. 10 or M6 (Part no.
SW305 or SW405) and wall plugs (Part no. PS305) - see Accessories
page 72.
Heavy duty cast cable saddle
Conductor
diameter
Conductor
material
Weight
each
Part
No.
For use with solid circular conductor
8 mm
Copper
0.09 kg
CP805
8 mm
Aluminium
0.03 kg
CP806
10 mm*
Copper
0.10 kg
CP815
10 mm*
Aluminium
0.04 kg
CP816
CP815
For use with stranded conductor
50 mm2
Copper
0.10 kg
CP810
mm2
Copper
0.10 kg
CP815
95 mm2
Copper
0.10 kg
CP835
70
* For use with PVC covered 8 mm conductor or for supporting air terminals when used in conjunction with
wall mounted air rod bases. Can also be used with glazing bar holdfast and back plate holdfast stem
(see page 63).
Manufactured from high quality copper and aluminium alloys for excellent
corrosion resistance and high pull off loads.
Fix using countersunk wood screws 11⁄2” No. 10 or M6 (Part no.
SW005 or SW105) and wall plugs (Part no. PS305) - see Accessories
page 72.
53
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
Non-metallic DC tape clip
Conductor
size
Colour
Weight
each
Part
No.
20 x 3 mm
Brown
0.01 kg
CP005
20 x 3 mm
Grey
0.01 kg
CP010
25 x 3 mm
Brown
0.01 kg
CP015
25 x 3 mm
Grey
0.01 kg
CP020
38 x 5 mm
Brown
0.01 kg
CP060*
50 x 6 mm
Brown
0.02 kg
CP065*
Brown
0.01 kg
CP025
25 x 3 mm
Black
0.01 kg
CP030
25 x 3 mm
Green
0.01 kg
CP035
25 x 3 mm
Grey
0.01 kg
CP040
25 x 3 mm
Stone
0.01 kg
CP045
25 x 3 mm
White
0.01 kg
CP050
For use with bare tape
CP020
For use with PVC covered tape
25 x 3 mm
* Not as illustrated (drawing available on request).
High grade Polypropylene, UV stabilized against degradation by sunlight
and non-brittle to prevent cold weather damage. Available in six colours to
match bare and PVC covered copper and aluminium tapes.
Fix using countersunk wood screws 11⁄2” No. 10 or M6 (Part no.
SW005 or SW105) and wall plugs (Part no. PS305) - see Accessories
page 72.
Non-metallic push-in clip
Conductor
diameter
Colour
Weight
each
Part
No.
For use with bare solid circular conductor
8 mm
Brown
0.01 kg
CP887
8 mm
Grey
0.01 kg
CP872
For use with PVC covered solid circular conductor
CP872
10 mm*
Brown
0.01 kg
CP886
10 mm*
Black
0.01 kg
CP861
mm*
Grey
0.01 kg
CP871
10 mm*
Stone
0.01 kg
CP876
mm*
White
0.01 kg
CP881
10
10
* PVC covered 8 mm conductor.
High grade Polypropylene, UV stabilized against degradation by sunlight and
non-brittle to prevent cold weather damage. Available in five colours to
match bare and PVC covered copper and aluminium solid circular conductors.
54
Fix using countersunk wood screws 11⁄2” No. 10 or M6 (Part no.
SW005 or SW105) and wall plugs (Part no. PS305) - see Accessories
page 72.
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
Glue down DC tape clip
Conductor
size
Colour
Weight
each
Part
No.
25 x 3 mm
Brown
0.03 kg
GD015
25 x 3 mm
Grey
0.03 kg
GD020
25 x 3 mm
Brown
0.03 kg
GD025
25 x 3 mm
Black
0.03 kg
GD030
25 x 3 mm
Grey
0.03 kg
GD040
25 x 3 mm
Stone
0.03 kg
GD045
25 x 3 mm
White
0.03 kg
GD050
For use with bare tape
For use with PVC covered tape
GD020
Disc diameter 85 mm.
Use on clay roof tiles. Supplied in a box of 50 complete with adhesive.
Additional glue gun is required.
For dressing tool, see page 59.
Glue down push-in clip
Conductor
diameter
Colour
Weight
each
Part
No.
For use with bare solid circular conductor
8 mm
Brown
0.03 kg
GD887
8 mm
Grey
0.03 kg
GD872
For use with PVC covered solid circular conductor
10 mm*
Brown
0.03 kg
GD886
10 mm*
Black
0.03 kg
GD861
10 mm*
Grey
0.03 kg
GD871
10 mm*
Stone
0.03 kg
GD876
10 mm*
White
0.03 kg
GD881
GD872
* PVC covered 8 mm conductor.
Disc diameter 85 mm.
Use on clay roof tiles. Supplied in a box of 50 complete with adhesive.
Additional glue gun is required.
55
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
Self adhesive DC tape clip
Conductor
size
Colour
Weight
each
Part
No.
25 x 3 mm
Brown
0.03 kg
CA015-FU
25 x 3 mm
Grey
0.03 kg
CA020-FU
25 x 3 mm
Brown
0.03 kg
CA025-FU
25 x 3 mm
Black
0.03 kg
CA030-FU
25 x 3 mm
Grey
0.03 kg
CA040-FU
25 x 3 mm
Stone
0.03 kg
CA045-FU
25 x 3 mm
White
0.03 kg
CA050-FU
For use with bare tape
For use with PVC covered tape
CA020-FU
Disc diameter 64 mm.
Designed to secure conductors to surfaces that cannot be penetrated by a
screw. Ideal for aluminium, spangled galvanized steel, colour coated steel,
glass, perspex, enamel and stainless steel etc. Manufactured from high
grade plastic, UV stabilized against degradation by sunlight and non-brittle
to prevent cold weather damage.
For dressing tool and surface primer, see page 59.
Use on surfaces other than PVC roofing.
Self adhesive push-in clip
Conductor
diameter
Colour
Weight
each
Part
No.
For use with bare solid circular conductor
8 mm
Brown
0.02 kg
CA887
8 mm
Grey
0.02 kg
CA872
For use with PVC covered solid circular conductor
CA872
10 mm*
Brown
0.02 kg
CA886
mm*
Black
0.02 kg
CA861
10 mm*
Grey
0.02 kg
CA871
10 mm*
Stone
0.02 kg
CA876
10 mm*
White
0.02 kg
CA881
10
* PVC covered 8 mm conductor.
Disc diameter 64 mm.
Designed as a means of securing conductors to surfaces that cannot be
penetrated by a screw. Ideal for aluminium, spangled galvanized steel,
colour coated steel, glass, perspex, enamel and stainless steel. Manufactured
from high grade plastic, UV stabilized against degradation by sunlight and
non-brittle to prevent cold weather damage.
For surface primer, see page 59.
56
Use on surfaces other than PVC roofing.
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
Solvent weldable DC tape clip
Conductor
size
Colour
Weight
each
Part
No.
25 x 3 mm
Brown
0.03 kg
CW015-FU
25 x 3 mm
Grey
0.03 kg
CW020-FU
25 x 3 mm
Brown
0.03 kg
CW025-FU
25 x 3 mm
Black
0.03 kg
CW030-FU
25 x 3 mm
Grey
0.03 kg
CW040-FU
25 x 3 mm
Stone
0.03 kg
CW045-FU
25 x 3 mm
White
0.03 kg
CW050-FU
For use with bare tape
For use with PVC covered tape
CW020-FU
Disc diameter 64 mm.
Provides a secure means of fixing conductors to single ply PVC roof
membranes. Manufactured from high grade PVC, UV stabilized against
degradation by sunlight and non-brittle to prevent cold weather damage.
For dressing tool and welding solvent, see page 59.
Clips are available for Polypropylene, Polyethylene and other roof
membranes - see page 58.
Solvent weldable push-in clip
Conductor
diameter
Colour
Weight
each
Part
No.
For use with bare solid circular conductor
8 mm
Brown
0.03 kg
CW887
8 mm
Grey
0.03 kg
CW872
For use with PVC covered solid circular conductor
10 mm*
Brown
0.03 kg
CW886
10 mm*
Grey
0.03 kg
CW871
CW872
* PVC covered 8 mm conductor.
Disc diameter 64 mm.
Provides a secure means of fixing conductors to single ply PVC roof
membranes. Manufactured from high grade PVC, UV stabilized against
degradation by sunlight and non-brittle to prevent cold weather damage.
For welding solvent, see page 59.
Clips are available for Polypropylene, Polyethylene and other roof
membranes - see page 58.
57
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
Heat weldable DC tape clip
NEW
Conductor
size
Colour
Weight
each
Part
No.
25 x 3 mm
Brown
0.03 kg
HW015-FU
25 x 3 mm
Grey
0.03 kg
HW020-FU
25 x 3 mm
Brown
0.03 kg
HW025-FU
25 x 3 mm
Black
0.03 kg
HW030-FU
25 x 3 mm
Grey
0.03 kg
HW040-FU
25 x 3 mm
Stone
0.03 kg
HW045-FU
25 x 3 mm
White
0.03 kg
HW050-FU
For use with bare tape
For use with PVC covered tape
HW020-FU
Disc diameter 85 mm.
Provides a secure means of fixing flat tape conductors to single ply
polypropylene, polyethylene and PVC roof membranes using an industrial
heat gun, where solvent welding is not applicable.
Manufactured from high grade PVC, UV stabilized against degradation by
sunlight and non-brittle to prevent cold weather damage.
For dressing tool, see page 59.
Heat weldable push-in clip
NEW
Conductor
diameter
Colour
Weight
each
Part
No.
For use with bare solid circular conductor
8 mm
Brown
0.03 kg
HW887
8 mm
Grey
0.03 kg
HW872
For use with PVC covered solid circular conductor
HW872
10 mm*
Brown
0.03 kg
HW886
10 mm*
Grey
0.03 kg
HW871
* PVC covered 8 mm conductor.
Disc diameter 85 mm.
Provides a secure means of fixing circular conductors to single ply
polypropylene, polyethylene and PVC roof membranes using an industrial
heat gun, where solvent welding is not applicable.
Manufactured from high grade PVC, UV stabilized against degradation by
sunlight and non-brittle to prevent cold weather damage.
58
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
Clip accessories
Description
Weight
each
Part
No.
Universal welding solvent
500 ml spray applicator (sufficient for application of approx
200 clips). Use with Furse solvent weldable clips only.
0.57 kg
CW905
Cleaning solution (Acetone)
500 ml spray applicator. For cleaning lacquered roofing
membranes.
0.62 kg
CW999
Surface primer
250 ml spray applicator (sufficient for application of
approx 500 clips). Use with Furse adhesive clips only.
0.24 kg
CA900
Dressing tool
For use with adhesive and weldable DC tape clips.
0.31 kg
CW905 / CW999 / CA900
DT100
Solvent and surface primer cannot be supplied outside the UK.
For overseas projects, please contact us for advice.
CoSHH Datasheets available on request.
DT100
Bitumen felt roof clip
Conductor
size
Colour
Weight
each
Part
No.
25 x 3 mm
Brown
0.09 kg
FP015
25 x 3 mm
Grey
0.09 kg
FP020
Brown
0.09 kg
FP025
25 x 3 mm
Black
0.09 kg
FP030
25 x 3 mm
Green
0.09 kg
FP035
25 x 3 mm
Grey
0.09 kg
FP040
25 x 3 mm
Stone
0.09 kg
FP045
25 x 3 mm
White
0.09 kg
FP050
For use with bare tape
For use with PVC covered tape
25 x 3 mm
FP020
For dressing tool, see above.
Use on bitumen felt roofing only.
59
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
Standing seam roof fixing with non-metallic DC tape clip
NEW
Conductor
size
Conductor
material
Colour
Weight
each
Part
No.
For use with bare tape
25 x 3 mm
Copper
-
0.076 kg
SC015
25 x 3 mm
Aluminium
-
0.076 kg
SC020
For use with PVC covered tape
SC040
25 x 3 mm
Copper/Aluminium
Brown
0.076 kg
SC025
25 x 3 mm
Copper/Aluminium
Black
0.076 kg
SC030
25 x 3 mm
Copper/Aluminium
Green
0.076 kg
SC035
25 x 3 mm
Copper/Aluminium
Grey
0.076 kg
SC040
25 x 3 mm
Copper/Aluminium
Stone
0.076 kg
SC045
25 x 3 mm
Copper/Aluminium
White
0.076 kg
SC050
Highly versatile, innovative standing seam roof fixing including non-metallic
DC tape clip, suitable for use on multi-profiled seam roofing structures up to
22 mm thickness. Use with bare and PVC covered copper and aluminium
conductors. Separate datasheet available on request.
Standing seam roof fixing with square tape clamp
NEW
SC105-H
Conductor
size
Conductor
material
Weight
each
Part
No.
25 x 3 mm
Copper
0.18 kg
SC105-H
25 x 3 mm
Aluminium
0.12 kg
SC005-H
Highly versatile, innovative standing seam roof fixing including square
tape clamp, suitable for use on multi-profiled seam roofing structures up to
22 mm thickness. Use with bare and PVC covered copper and aluminium
conductors. Separate datasheet available on request.
60
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
Puddle flange
Conductor
material
Weight
each
Part
No.
Copper
1.54 kg
PF105
Aluminium
0.50 kg
PF005
Permits lightning conductors to pass through flat roofs without damaging
the waterproof nature of the roof.
150 mm
150 mm
450 mm
ø5/8”
PF105
Pyramid holdfast
Conductor
diameter
Weight
each
Part
No.
8 mm
0.97 kg
HF975
Designed to secure bare, 8 mm diameter, circular conductors to flat roofs.
Supplied filled with concrete the conductor is held in place by the weight of
the holdfast.
The lip around the base of the product permits the holdfast to be built into
bitumen type roofs.
HF975
140 mm
140 mm
79 mm
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
61
Conductor network
Slate holdfast with non-metallic DC tape clip
Conductor
size
DC Clip
Colour
Weight
each
Part
No.
25 x 3 mm
Brown
0.06 kg
HF015
25 x 3 mm
Grey
0.06 kg
HF020
25 x 3 mm
Brown
0.06 kg
HF025
25 x 3 mm
Black
0.06 kg
HF030
25 x 3 mm
Grey
0.06 kg
HF040
25 x 3 mm
Stone
0.06 kg
HF045
For use with bare tape
For use with PVC covered tape
HF040
Designed to allow tape conductors to be fixed to tiled roofs without
compromising the waterproofing nature of the roof. The 500 mm tail fits
neatly between overlapping tiles and is wrapped around/fixed to the tile
lathe for secure fitting.
Slate holdfast with non-metallic push-in clip
HF191
Conductor
diameter
Colour
Weight
each
Part
No.
8 mm
Brown
0.03 kg
HF176
8 mm
Grey
0.03 kg
HF191
Designed to allow circular conductors to be fixed to tiled roofs without
compromising the waterproofing nature of the roof. The 500 mm tail fits
neatly between overlapping tiles and is wrapped around/fixed to the tile
lathe for secure fitting.
62
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
Glazing bar holdfast
Conductor
material
Maximum glazing
bar width
Weight
each
Part
No.
Copper
12 mm
0.11 kg
HF705
Aluminium
12 mm
0.05 kg
HF710
Manufactured from high quality copper and aluminium alloys. Simple to
install, providing secure anchorage to thin metallic sections that cannot be
drilled e.g. window mullions, angle iron etc. Once fixed any metallic or
non-metallic conductor clip can be attached with the screw provided.
HF705
Conductor clip sold separately.
Back plate holdfast stem
Conductor
material
Weight
each
Part
No.
Copper
0.30 kg
HF320
Aluminium
0.10 kg
HF325-FU
Supplied with M6 fixing screw to secure appropriate conductor clip.
Fix using roundhead wood screws 11⁄2” No. 10 or M6 (Part no.
SW305 or SW405) and wall plugs (Part no. PS305) - see Accessories
page 72.
HF320
63
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
Square clamp
NEW
Conductor
size
Conductor
material
Weight
each
Part
No.
25 x 3 mm
Copper
0.12 kg
CT105-H†
25 x 6 mm
Copper
0.30 kg
CT110-H†
50 x 6 mm
Copper
0.60 kg
CT115-H†
25 x 3 mm
Aluminium
0.06 kg
CT005-H
25 x 6 mm
Aluminium
0.17 kg
CT010-H
CT105-H
Manufactured from high quality copper and aluminium alloys. Simple
to install, providing an effective low resistance connection between
overlapping tapes to allow cross, tee, through and right angle joints to
be formed.
BS EN 50164-1 Class H
†
UL96 (CT105H, CT110-H, CT115-H)
Fix using countersunk wood screws 11⁄2” No. 10 or M6 (Part no.
SW005 or SW105) and wall plugs (Part no. PS305) - see Accessories
page 72.
Tightening torque 5 Nm
Crossover clamp
Conductor
size
CX105-H
Conductor
material
Weight
each
Part
No.
25 x 3 mm
Copper
0.09 kg
CX105-H
25 x 3 mm
Aluminium
0.03 kg
CX005-H
Manufactured from high quality copper and aluminium alloys. Simple to
install, providing an effective low resistance connection between
overlapping tapes to allow cross joints to be formed.
BS EN 50164-1 Class H
Fix using countersunk wood screws 11⁄2” No. 10 or M6 (Part no.
SW005 or SW105) and wall plugs (Part no. PS305) - see Accessories
page 72.
Tightening torque 5 Nm
64
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
Cable to tape square clamp
Conductor
size
Conductor
material
Weight
each
Part
No.
25 x 3 mm to 50 mm²
Copper
0.32 kg
CT125
25 x 3 mm to 70 mm²
Copper
0.30 kg
CT130
25 x 3 mm to 95 mm²
Copper
0.28 kg
CT135
NEW
NEW
Manufactured from high quality copper alloy. Simple to install, providing
an effective low resistance connection between conductor tape and
stranded copper conductor, allowing cross, tee, through and right angle
joints to be formed.
CT130
BS EN 50164-1 Class H
Fix using countersunk wood screws 11⁄2” No. 10 or M6 (Part no.
SW005) and wall plugs (Part no. PS305) - see Accessories page 72.
Tightening torque 5 Nm
Square clamp
Conductor
diameter
Conductor
material
Weight
each
Part
No.
50 mm2
Copper
0.32 kg
CR810
70 mm2
Copper
0.29 kg
CR815
mm2
Copper
0.25 kg
CR820
95
Manufactured from high quality copper alloy. Simple to install, providing an
effective low resistance connection between overlapping stranded
conductors allowing cross, tee, through and right angle joints to be formed.
CR815
BS EN 50164-1 Class H
Tightening torque 6 Nm
65
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
Square clamp
Conductor
diameter
Conductor
material
Weight
each
Part
No.
8 mm
Copper
0.17 kg
CS605
8 mm
Aluminium
0.07 kg
CS610
Designed to provide low resistance cross joints in solid circular conductor
networks. Manufactured from high quality copper and aluminium alloys for
excellent corrosion resistance.
CS605
BS EN 50164-1 Class H
Tightening torque 12 Nm
Tee clamp
Conductor
diameter
Conductor
material
Weight
each
Part
No.
8 mm
Copper
0.17 kg
CS505
8 mm
Aluminium
0.07 kg
CS510
Designed to provide low resistance tee joints in solid circular conductor
networks. Manufactured from high quality copper and aluminium alloys for
excellent corrosion resistance.
CS505
BS EN 50164-1 Class H
Tightening torque 12 Nm
66
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
Jointing clamp
Conductor
diameter
Conductor
material
Weight
each
Part
No.
8 mm
Copper
0.17 kg
CS405
8 mm
Aluminium
0.08 kg
CS410
Designed to provide low resistance parallel joints in solid circular conductor
networks. Manufactured from high quality copper and aluminium alloys for
excellent corrosion resistance.
CS405
BS EN 50164-1 Class H
Tightening torque 12 Nm
Test/junction clamp
Conductor
size
Conductor
material
Weight
each
Part
No.
26 x 8 mm
Copper
0.29 kg
CN105-H†
26 x 8 mm
Aluminium
0.12 kg
CN005*
* Not as illustrated (drawing available on request).
Manufactured from high quality copper and aluminium alloys. Simple to
install, providing an effective low resistance connection between
overlapping tapes. The clamped connection is easily made/remade to allow
for periodic testing.
CN105-H
BS EN 50164-1 Class H
†
UL96 (CN105-H)
Tightening torque CN005 15 Nm; CN105-H 13 Nm
67
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
Plate type test clamp
Maximum
conductor size
26 x 12 mm
Conductor
material
Weight
each
Part
No.
Copper
0.62 kg
CT405
Manufactured from a high quality copper alloy. Simple to install, providing
an effective low resistance connection between overlapping tapes. The
clamped connection is easily made/remade to allow for periodic testing.
Enables cross, tee, through and right angle joints to be formed.
CT405
BS EN 50164-1 Class H
Fix using countersunk wood screws 11⁄2” No. 10 or M6 (Part no.
SW005) and wall plugs (Part no. PS305) - see Accessories page 72.
Tightening torque 15 Nm
Screwdown test clamp
Maximum
conductor size
26 x 8 mm
Conductor
material
Weight
each
Part
No.
Copper
0.84 kg
CT305
Manufactured from a high quality copper alloy. Simple to install, providing
an effective low resistance connection between overlapping tapes. The
clamped connection is easily made/remade to allow for periodic testing.
Enables cross, tee, through and right angle joints to be formed.
CT305
BS EN 50164-1 Class H
Fix using countersunk wood screws 11⁄2” No. 10 or M6 (Part no.
SW005) and wall plugs (Part no. PS305) - see Accessories page 72.
Tightening torque 20 Nm
68
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
Test clamp
Conductor
diameter
Conductor
size
Conductor
material
Weight
each
Part
No.
8 mm
25 x 3 mm
Copper
0.20 kg
CN305
8 mm
25 x 3 mm
Aluminium
0.09 kg
CN310
Designed to provide low resistance tee joints in solid circular conductor
networks. These multi-purpose clamps can produce circular to circular or
circular to tape connection in both through and tee configurations.
Manufactured from high quality copper and aluminium alloys for excellent
corrosion resistance.
CN305
BS EN 50164-1 Class H
Tightening torque 12 Nm
Test clamp
Conductor
diameter
Conductor
material
Weight
each
Part
No.
50 mm2
Copper
0.39 kg
CR855
70 mm2
Copper
0.40 kg
CR860
mm2
Copper
0.40 kg
CR865
95
Manufactured from high quality copper alloy. Simple to install, providing an
effective low resistance overlap connection between stranded copper cables.
CR860
BS EN 50164-1 Class H
Fix using countersunk wood screws 11⁄2” No. 10 or M6 (Part no.
SW005) and wall plugs (Part no. PS305) - see Accessories page 72.
Tightening torque 12 Nm
69
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
Bimetallic connector
Conductor
size
Weight
each
Part
No.
25 x 3 mm aluminium tape to 25 x 3 mm copper tape
0.19 kg
CN910
1 ⁄2” x ⁄8” aluminium tape to 1” x ⁄8” copper tape
0.19 kg
CN910-UL†
8 mm diameter aluminium conductor to 8 mm diameter
copper conductor
0.25 kg
CN915
8 mm diameter aluminium conductor to 25 x 3 mm
copper tape
0.19 kg
CN920
25 x 3 mm aluminium tape to 25 x 3 mm copper tape
0.20 kg
CN925
1
CN910
1
1
Manufactured from a friction welded joint between high conductivity
copper and aluminium to provide the ideal means of interconnecting copper
and aluminium conductors whilst avoiding bimetallic corrosion.
BS EN 50164-1 Class H
†
UL96 (CN910-UL)
CN915
Fix using countersunk wood screws 11⁄2” No. 10 or M6
(Part no. SW005 or SW105) and wall plugs (Part no. PS305) see Accessories page 72.
Tightening torque 12 Nm
CN925
CN910 illustrated
70
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Conductor network
Oxide inhibiting compound
Description
Weight
each
Part
No.
Plastic 8 oz bottle
0.23 kg
CM005
For all the items in this range we recommend the use of oxide inhibitor
when aluminium fittings are installed.
Oxide inhibitor is a non-water soluble, natural-petroleum based polymer
grease that seals electrical connections from oxygen and moisture.
CoSHH Datasheet available on request.
CM005
Expansion braid bond
Type
Conductor
material
Length
Cross-sectional
area
Weight
each
Part
No.
Single length
Copper
200 mm
50 mm2
0.17 kg
BN101
Single length
Aluminium
200 mm
50 mm2
0.07 kg
BN001
mm2
0.53 kg
BN102
0.23 kg
BN002
Cross-over
Copper
300 mm
50
Cross-over
Aluminium
300 mm
50 mm2
Designed to remove the risk of damage or distortion to long conductor runs
caused by thermal expansion and contraction.
BN102
71
Furse, Wilford Road, Nottingham, NG2 1EB • Tel: +44 (0)115 964 3700 • Email: enquiry@furse.com • Web: www.furse.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF