Below you will find brief information for NPort 5100A 5110A, NPort 5100A 5130A, NPort 5100A 5150A. These serial servers allow you to connect RS-232, RS-422/485, and RS-232/422/485 serial devices to a TCP/IP-based Ethernet network. The NPort 5100A series devices are compact, palm-sized communication devices that have one male DB9 port for transmitting serial data. The NPort 5100A series device servers come with a user-friendly NPort Administration Suite software that allows you to manage and configure devices. It also offers a user-friendly graphical user interface for managing and configuring your device.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

NPort 5100A 5110A, NPort 5100A 5130A, NPort 5100A 5150A Quick Installation Guide | Manualzz

NPort 5100A Series

Quick Installation Guide

Second Edition, June 2010

1. Overview

NPort 5100A series device servers are compact, palm-sized data communication devices that allow you to control RS-232 (NPort 5110A),

RS-422/485 (NPort 5130A), and RS-232/422/485 (NPort 5150A) serial devices over a TCP/IP-based Ethernet.

Note: “-T” indicates an extended temperature model.

2. Package Checklist

Before installing the NPort 5100A series device server, verify that the package contains the following items:

 1 NPort 5100A serial device server

 4 stick-on pads

 Document & Software CD

 Quick Installation Guide

 Product Warranty Statement

Optional Accessory

 DK-35A: DIN-Rail Mounting Kit (35 mm)

Notify your sales representative if any of the above items are missing or damaged.

3. Hardware Introduction

As shown in the following figures, NPort 5100A series device servers have one male DB9 port for transmitting RS-232 (NPort 5110A),

RS-422/485 (NPort 5130A), or RS-232/422/485 (NPort 5150A) serial data.

— 1—

P/N: 1802051000021

Off

No data is being transmitted or received through the serial port.

Adjustable pull high/low resistor for RS-

422/485 (150 KΩ or 1 KΩ)

Jumpers are used to set the pull high/low resistor value s. The default is 150 KΩ. Short the jumpers to set this value to 1 KΩ. Do not use the 1

KΩ setting with RS-232 mode, since doing so will degrade the RS-232 signals and shorten the communication distance.

NOTE: The NPort 5110A, NPort 5130A, and NPort 5150A have the same form factor.

Reset ButtonPress and hold the Reset button for 5 seconds to load

factory defaults: Use a pointed object, such as a straightened paper clip or toothpick, to depress the reset button. This will cause the Ready LED to blink on and off. The factory defaults will be loaded once the Ready LED stops blinking (after about 5 seconds). At this point, release the reset button.

LED Indicators—NPort 5100A’s top panel has three LED indicators, which are described in the following table.

LED

Name

Ready

LED

Color

LED Function

Steady on: Power is on and the NPort is booting up.

Red

Blinking: Indicates an IP conflict, or DHCP or

BOOTP server is not responding properly.

Steady on: Power is on and the NPort is functioning normally.

Green

Blinking: The NPort has been located by the NPort

Administrator’s Location function.

Off Power is off, or a power error..

Link

Orange 10 Mbps Ethernet connection.

Green 100 Mbps Ethernet connection.

Off Ethernet cable is disconnected.

Tx/Rx

Orange Serial port is receiving data.

Green Serial port is transmitting data.

— 2 —

4. Hardware Installation Information

STEP 1: After removing the NPort 5100A series device server from the box, connect the NPort 5100A series device server to a network. Use a standard straight-through Ethernet cable to connect to a hub or switch.

When setting up or testing the NPort 5100A series device server, you might find it convenient to connect directly to your computer’s Ethernet port. In this case, use a cross-over Ethernet cable.

STEP 2: Connect the NPort 5100A series device server’s serial port to a serial device.

STEP 3: Connect the power adaptor.

STEP 4: Placement options.

In addition to placing the NPort 5100A on a desktop or other horizontal surface, you may also make use of the DIN-Rail or Wall Mount options, as illustrated below.

Wall Mount DIN-Rail

— 3 —

5. Software Installation Information

To install NPort Administration Suite, insert the NPort Document &

Software CD into your computer’s CD-ROM drive. Once the NPort

Installation CD window opens, click on the Installation button, and then follow the instructions on the screen.

To view detailed information about NPort Administration Suite, click on the Documents button, and then select “NPort 5100A Series User’s

Guide” to open the pdf version of the user’s guide.

6. Pin Assignments

Ethernet Port Pinouts

Pin Number

1

2

3

6

Ethernet

Tx+

Tx-

Rx+

Rx-

NPort 5110A—DB9 male (RS-

232) port pinouts

Pin Number

1

2

RS-232

DCD

RxD

3

4

5

6

7

8

9

TxD

DTR

GND

DSR

RTS

CTS

---

—4—

NPort 5130A—DB9 male (RS-422/485

) port pinouts

Pin Number

1

RS-

422/485 (4W)

TXD-(A)

RS-

485 (2W)

---

2

3

4

TXD+(B)

RXD+(B)

RXD-(A)

---

Data+(B)

Data-(A)

5

6

7

GND

---

---

GND

---

---

8

9

Pin Number

1

RS-232

DCD

RxD

TxD

---

---

NPort 5150A—DB9 male (RS-232/422/485

) port pinouts

RS-422/

---

---

485 (4W)

TXD-(A)

TXD+(B)

RXD+(B)

RS-

485 (2W)

---

---

Data+(B)

2

3

4

5

6

7

DTR

GND

DSR

RTS

RXD-(A)

GND

---

---

Data-(A)

GND

---

---

8

9

CTS

---

---

---

---

---

7. Specifications

Power Requirements

Power Input 12 to 48 VDC

Power Consumption NPort 5110A: 82.5 mA@12V, 47.3 mA@24V

NPort 5130A: 89.1 mA@12V, 49.5 mA@24V

NPort 5150A: 92.4 mA@12V, 52.8 mA@24V

—5 —

Operating Temperature 0 to 60°C (32 to 140°F), for standard models

-40 to 75°C (-40 to 167°F), for -T models

Operating Humidity 5 to 95% RH

Dimensions 75.2

× 80 × 22 mm

(2.96

× 3.15 × 0.87 in)

52

× 80 × 22 mm

(2.05

× 3.15 × 0.89 in)

with ears

without ears

Serial Line Protection 15 KV ESD for serial port

Level 1 Surge, EN61000-4-5

Magnetic Isolation 1.5 KV for Ethernet

Power Line Protection Level 2 Burst (EFT), EN61000-4-4

Level 3 Surge, EN61000-4-5

Regulatory Approvals FCC Class A, CE Class A, UL, LVD

Click here for online support: www.moxa.com/support

The Americas: +1-714-528-6777 (toll-free: 1-888-669-2872

)

Europe: +49-89-3 70 03 99-0

Asia-Pacific: +886-2-8919-1230

China: +86-21-5258-9955 (toll-free: 800-820-

5036)

2010 Moxa Inc. All rights reserved.

Reproduction without permission is prohibited.

— 6 —

advertisement

Key Features

  • RS-232, RS-422/485, or RS-232/422/485 serial devices support
  • TCP/IP-based Ethernet network communication
  • Compact, palm-sized design
  • NPort Administration Suite software for management
  • User-friendly graphical user interface
  • DIN-Rail or Wall Mount options
  • Extended temperature models (-40 to 75°C)

Frequently Answers and Questions

How do I set the pull high/low resistor values for the RS-422/485 port?
You can set the pull high/low resistors to 150 KΩ or 1 KΩ. The default is 150 KΩ. To set it to 1 KΩ, short the jumpers as described in the manual. Do not use the 1 KΩ setting with RS-232 mode, since it will degrade the RS-232 signals and shorten the communication distance.
How do I reset the NPort 5100A series device server to factory defaults?
Press and hold the Reset button for 5 seconds. This will cause the Ready LED to blink on and off. Once the Ready LED stops blinking, release the reset button. The factory defaults will be loaded.
What are the LED indicators on the NPort 5100A series device server and what do they mean?
The NPort 5100A has three LED indicators: Ready, Link, and Tx/Rx. Refer to the table in the manual to understand the meaning of different LED states.

Related manuals

Download PDF

advertisement