Maico hearing screening brochure rvsd

Maico hearing screening brochure rvsd
Official Philippine Distributor:
WellnessPRO
tomorrow’s medical devices
Unit 1006 Richmonde Plaza, San Miguel Avenue corner
Lourdes St., Ortigas Center Pasig 1605, Philippines
Email: wellnessproinc@gmail.com
jcjuan@wellnessproinc.com
Tel: (02) 636-3580 • Fax: (02) 636-7542
Mobile: (63) 999-887-0247, (63) 922-823-2282
www.wellnessproinc.com
NEWBORN HEARING SCREENING
Medical Instruments
Berlin, Germany
Name
MB 11 BERAphone
Item No.
Name
Item No.
701 174
ERO • SCAN™ Screener
DPOAE - Screener
TEOAE - Screener
DPOAE + TEOAE Combo
701 142
701 143
701 146
Innovation,
Continuity,
Reliability.
Specifications
Specifications
Number of channels
Pursuant of
Philippine Republic Act
(R.A.) 9709
and
Department of Health
A.O. 2010-0020
1
Probe
Screening
Measurement type
TEOAE or DPOAE
Stimulus type
CE-Chirp stimulus™
Frequency range
2 to 5 kHz (DPOAE),1.5 to 4 kHz (TEOAE)
Stimulus rate
93/s
Stimulus intensity range
40 to 65 dB SPL
Stimulus levels
35 dBHL
Maximum output
90 dB SPL
Display
Normal mode test result
(PASS/REFER/ABORT), test diagram,
Microphone system noise
-15 dBSPL @ 1 kHz (1 Hz BW)
Stimulus sampling rate
31.25 Hz
for impedance test.
Power supply
6 V- batteries - four AA cells
Signal quality check
By signal quality bar (EEG) AABR-Algorithm
patented FSS-test (fast steady state)
Battery life
typical 300 tests
Probe weight
300 g (including batteries)
Sensitivity
> 99,9 %
Display
LCD-display 4 lines x 10 characters
Standards
IEC 601-1, BF according to medical directive
93/42/EEC, CE 0124
Power supply
Environmental Conditions
Speaker
Electrodes
Preamplifier
Weight
Instrument
(MB 11 Box):
Power Supply
Power Consumption
Weight
Dimensions
Standard
Accessories
MB 11 Box
Measuring Probe
Cradle
Carrying Case
Software
Electrode Gel
USB Cable
User Manual
Printer (optional)
Printer type
Thermal dot matrix
USB-Port 5V DC max. 400 mA
Speed
> 10 lines / second
+15 ... + 35 C / + 59 ... + 95° F (operation)
+ 5 ... + 50 C / + 41 ... + 122° F (storage)
Maximum humidity 75% (operation)
Maximum humidity 90% (storage)
Operating noise
< 50 dB SPL
Power supply
Mains 100 ... 240 V 50/60 Hz
Printer weight
630 g (with power supply or battery pack)
Integrated, dynamic wideband speaker (8)
Reusable, stainless-steel electrodes with
gel protectors
General
Standards
IEC 601-1, according to medical Directive
93/42/EEC, FDA 510 (k) #980533 23.3.1998,
CE 0124
PC-interface
serial RS 232
Integrated, 87 dB Amplification (23.000x)
300g
max. 400 mA
165 g
W x D x H: 12 x 9 x 3 cm
Optional Accessories
Item No.
Label Printer
Consumables
Stainless Steel Electrodes (1 pc.)
Stainless Steel Electrodes
for Pre-Matures (1pc.)
Gel Protection for Electrodes
(1 set of 3 pcs.)
Electrode Gel, Bottle 250 ml
801 793
894 132
894 153
Device with 4 AA Batteries
Cradle
Ear Tip Set (80 pcs)
Replacement Probe Tips
External Mini Probe
Replacement Probe Tips
for External Probe
Operating Manual
Optional Software
894 170
MAICO Database 706 019
801 086
OAE Module
705 190
MAICO MB 11 BERAphone® Screener
AABR Test System
Optional
Accessories
Standard
Accessories
via USB port of computer
Item No. 701174
Item No.
External Mini-Probe for Tests
on Babies - in TEOAE Mode
Printer with Power Supply
Carrying Case
Consumables
Probe Tips
Ear Tips Size 3
Ear Tips Size 4
Ear Tips Size 5
Ear Tips Size 6
Ear Tips Size 7
Ear Tips Size 8
705 081
705 063
705 064
705 065
705 066
705 067
705 068
Automated Auditory
Brainstem Response Technology
801 127
801 641
705 084
Ear Tips Size 9
Ear Tips Size 10
Ear Tips Size 11
Ear Tips Size 12
Ear Tips Size 13
Ear Tips Size 14
Ear Tips Size 15
Official Philippine Distributor:
Item No. 701142 / 701143 / 701146
705 089
705 090
MAICO ERO
705 091
705 092
705 093
Berlin, Germany
705 094
www.maico.biz
705 095
SCAN™ Screener
OAE Test System
Otoacoustic Emission Technology
WellnessPRO
tomorrow’s medical devices
Unit 1006 Richmonde Plaza, San Miguel Avenue corner Lourdes St., Ortigas Center Pasig 1605, Philippines
Tel: (02) 636-3580 • Fax: (02) 636-7542 • Mobile: (63) 999-887-0247, (63) 922-823-2282
Email: wellnessproinc@gmail.com • jcjuan@wellnessproinc.com
www.wellnessproinc.com
MAICO MB11 BERAphone
®
AABR Test System
Automatic Auditory Brainstem Response Technology
Item No. 701174
New Life, New Symphony,
ASSURED EARLY
for Every Filipino
Child.
Why screen via AABR method?
Screening with auditory brainstem response
is a direct test of the entire auditory pathway
up to the brainstem. It also detects auditory
neuropathy and other neural defects which
cannot be found with OAE measurements.
With the MB 11BERAphone® you get
automatic ABR at the speed and cost of OAE
measurement and with very high sensitivity
and specificity.
MAICO ERO · SCAN™
OAE Test System
Otoacoustic Emission Technology
Item No. 701142 / 701143 / 701146
Why Use Otoacoustic
Emissions (OAEs)?
Otoacoustic emissions are sounds that are produced by the
cochlea (outer hair cells) and can be measured in the ear
canal. When sound passing through the ear canal reaches the
cochlea, the vibration stimulates thousands of tiny hair cells.
This creates a byproduct that can be detected and measured:
OAEs only occur in a normal cochlea with normal hearing
sensitivity. If there is damage to the outer hair cells, which
produces hearing loss, then OAEs will not be present. In
general, OAEs will be present if hearing, is at 30 dB or better.
PASS test results mean OAEs were detected. If there is damage to the outer hair cells producing a mild hearing loss
OAEs may not be present. The test result is REFER and the
patient may be at risk for possible communication handicaps
and can benefit from further diagnostic assessment.
“…it´s so easy...!“
•
•
• Test both ears in less than a minute
• Results are displayed as PASS or REFER
•T
• With integrated thermal printer;
prints results in 2-3 seconds
• Accurate results
integrated electrodes
•
•
“AABR testing is the GOLD standard..”
•
User-friendly software
• Can come in DPOAE, TEOAE or combo
versions
OAE-Software
The new CE-Chirp
Stimulus
The CE-Chirp™ stimulates all regions of the
cochlea at the same time and generates much
higher responses than a standard click. It delivers most reliable screening test results even
in normal ENT-offices.
The special evaluation software performs the test automatically and the Pass or
Refer Result will show within a few seconds.
WellnessPRO
tomorrow’s medical devices
Official Philippine Distributor
Time course and frequency spectrum of the cosine
functions used for the CE-Chirp™ Stimulus
PC connectivity for optional software for report storage
Official Philippine Distributor
WellnessPRO
tomorrow’s medical devices
Was this manual useful for you? yes no