ThermoVision™ A20
ThermoVision™
A20-M + Researcher™
Affordable infrared imaging and
measurement package for scientific
applications.
The ThermoVision A20-M + Researcher package offers an
affordable but accurate measurement solution for Research &
Development applications. It can detect subtle temperature
variations that can signal significant component or design
problems.
Extremely easy to operate, the user intuitive ThermoVision
A20-M helps you clearly understand the thermal characteristics
of products and processes. It delivers the critical information
needed to cost-effectively solve design problems and improve
reliability.
AFFORDABLE RESEARCH PACKAGE
The ThermoVision A20-M + Researcher Package consists
of a rugged IR camera and the ThermaCAM Researcher
Software. It provides an affordable, flexible and powerful
solution for real-time thermal analysis.
PRECISION
NON-CONTACT TEMPERATURE MEASUREMENT
AND EXCELLENT IMAGE QUALITY
The ThermoVision A20-M allows you to see temperature
differences as small as 0.10 °C in a range from -20 °C up to
+900 °C. It produces crisp high-resolution images (160x 120
pixels) offering more than 19,200 individual measurement
points per image at a refresh rate of 50/60 Hz.
IEEE-1394 FIREWIRE OUTPUT
Enhanced connectivity options include composite video and
IEEE-1394 interface for superfast image and data transfer
of real-time, fully radiometric 16-bit images.
EASY OPERATION: PLUG AND PLAY
Simply connect the camera to a PC or a monitor and
produce high-quality real-time radiometric images. The
camera can be fully controlled either from the PC or with
the integrated keyboard.
INTEGRATED KEYBOARD
For those applications where the infrared camera and the
PC are a distance away from each other, the ThermoVision
A20-M has an integrated keyboard. With a few buttons,
conveniently placed at the top of the camera, you can
control all features.
ULTRA-COMPACT, RUGGED AND LIGHTWEIGHT
Compact and extremely lightweight, this portable yet powerful research device fits easily on your bench. It can be
carried to other test or hard-to-get-at locations for fast,
mobile data acquisition and analysis in the lab or on the
manufacturing floor.
•
AFFORDABLE,
FULLY INTEGRATED THERMAL
MEASUREMENT SOLUTION
•
•
•
•
•
PRECISION NON-CONTACT TEMPERATURE MEASUREMENT
HIGH-QUALITY THERMAL IMAGES (160 X 120 PIXELS)
RUGGED AND COMPACT
FIREWIRE (IEEE-1394) DIGITAL OUTPUT
THERMACAM RESEARCHER SOFTWARE
FOR DETAILED THERMAL ANALYSIS
TAILORED TO YOUR APPLICATION
As with all its products, FLIR Systems offers a complete
series of accessories, including close-up and wide-angle
lenses, to suit the most demanding applications.
THERMACAM RESEARCHER: POWERFUL,
REAL-TIME STORAGE AND ANALYSIS SOFTWARE
ThermaCAM Researcher has been developed for use in
scientific environments where detailed thermal analysis of
dynamic events is required. It offers powerful built-in
measurement and analysis functions (isotherms, spot
measurements, line profiles, area histograms, image
subtraction capability, etc.) for fast and extensive
temperature analysis.
TECHNICAL SPECIFICATIONS
IMAGING PERFORMANCE
Field of view/min focus distance
Spatial resolution (IFOV)
Thermal sensitivity
Focusing
Detector type
Spectral range
Typical 19° x 14°/0.3 m (with 17 mm lens)
2.1 mrad
0.10°C at 30°C
Manual
Focal Plane Array (FPA), uncooled microbolometer
7.5 to 13 µm
IMAGE PRESENTATION
ThermoVision™ A20-M+
Researcher™ includes:
Image output
RS170 EIA/NTSC or CCIR/PAL analog composite video and
FireWire (IEEE-1394) 8-/16-bit digital image output
MEASUREMENT
Temperature ranges
•
•
•
•
•
•
IR CAMERA
POWER SUPPLY INCLUDING
FIREWIRE CABLE
(FIREWIRE VERSION ONLY)
CONFIGURATION CD
LENS CAP
MANUAL
FLIR SYSTEMS AB
World Wide Thermography Center
Rinkebyvägen 19 - PO Box 3
SE-182 11 Danderyd
Sweden
Tel.: +46 (0)8 753 25 00
Fax: +46 (0)8 753 23 64
e-mail: sales@flir.se
www.flir.com
FLIR SYSTEMS LTD.
United Kingdom
Tel.: +44 (0)1732 220 011
e-mail: sales@flir.uk.com
FLIR SYSTEMS CO. LTD.
Hong Kong
Tel.: +852 27 92 89 55
e-mail: flir@flir.com.hk
FLIR SYSTEMS GMBH
Germany
Tel.: +49 (0)69 95 00 900
e-mail: info@flir.de
FLIR SYSTEMS SARL
France
Tel.: +33 (0)1 41 33 97 97
e-mail: info@flir.fr
CABLE
Accuracy
Measurement modes
Emissivity corrections
Reflected ambient temperature
correction
External optics / window correction
-20°C to +250°C (-4°F to +482°F)
to +900°C (+1652°F) (optional)
± 2°C, ± 2% of reading
Spot, area, isotherm, Delta T, iso-coverage
Variable from 0.1 to 1.0
Automatic, based on input of
reflected temperature
Automatic, based on input of optics/window transmission and temperature
LENSES (OPTIONAL)
2 x Telescope
0.5 Wide angle
0.25 Wide angle
Typical 9° x 7°/1.2 m (with 36 mm lens)
Typical 34° x 25°/0.1 m (with 9 mm lens)
Typical 60 x 45°/0.1 m (with 4.5 mm lens)
POWER SOURCE
AC operation
Voltage
AC adapter 110/220 V AC, 50/60 Hz
12/24 V nominal, < 6 W
ENVIRONMENTAL
SPECIFICATIONS
Operating temperature range
Storage temperature range
Humidity
Encapsulation
Shock
Vibration
-15°C to +55°C (+5°F to +122°F)
-40°C to +70°C (-40°F to +158°F)
Operating and storage 10% to 95%, non condensing
IP 40 (determined by connector type)
Operational: 25G, IEC 68-2-29
Operational: 2G, IEC 68-2-6
PHYSICAL CHARACTERISTICS
Weight
Size
0.8 kg (1.7 lbs)
157 mm x 75 mm x 80 mm
(6.2" x 2.9" x 3.1")
1/4" - 20
Tripod Mounting
INTERFACES
Digital image output
and camera control
BNC
6-pin screw terminal (upper)
6-pin screw terminal (lower)
6-pin FireWire (IEEE-1394) connector handling iso-chronous
16-bit digital image data and asynchronous control data
Composite video (NTSC/PAL)
Digital I/O: 3 Output - 1 Input
1 Input/Output selectable. User configurable*
Analog I/O: 2 Output - 1 Input,
User configurable* - see user configuration table
FLIR SYSTEMS S.R.L.
Italy
Tel.: +39 02 99 45 10 01
e-mail: info@flir.it
FLIR SYSTEMS AB
Belgium
Tel.: +32 (0)3 287 87 10
e-mail: info@flir.be
WWW.FLIR.COM
USER CONFIGURATION TABLE*
TYPE
FUNCTION
REMARK
Digital input
TTL Level: Shutter disable, Store image,
Batch enable
TTL Level: Spot / Area threshold alarm,
Internal temperature sensor alarm, V-sync
Spot / Area out 0 - 5 V,
Internal temperature sensor out 0 - 5 V
External temperature sensor in 0 - 10 V
Isolation and relay function in
external module
Isolation and relay function in
external module
Scaled to Tlow - Thigh
Isolation in external module
Scaled to Tlow - Thigh
Isolation in external module
Digital output
Analog output
Analog input
SPECIFICATIONS ARE SUBJECT TO
CHANGE WITHOUT NOTICE
©Copyright 2004, FLIR Systems, Inc.
All other brand and product names are
trademarks of their respective owners
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising