C:\Documents and Settings\Owner.BOB\My

C:\Documents and Settings\Owner.BOB\My
INSTRUCTION MANUAL
MODEL PCD-88
CLOSED CAPTION DECODER
LINK
ELECTRONICS, INC.
e-mail: sales @ linkelectronics.com
website: www.linkelectronics.com
2137 Rust Avenue
Cape Girardeau, Missouri 63703
Phone: 573-334-4433
Fax: 573-334-9255
TABLE OF CONTENTS
Important Safeguards and Notices: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
To prevent injury: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
North American Power Supply Cords: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
International Power Supply Cord: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
TOP AND END VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7
GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 8
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 9
SETUP PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 10
PRODUCT WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 11
Important Safeguards and Notices
Information on the following pages provides important safety guidelines for both Operator
and Service personnel. Specific warnings and cautions will be found throughout the manual
where they apply, but may not appear here. Please read and follow the important safety
information, noting especially those instructions related to risk of fire, electric shock or injury
to persons.
WARNING
Any instructions in this manual that require opening the equipment cover
or enclosure are for use by qualified service personnel only. To reduce the
risk of electric shock, do not perform any servicing other than that
contained in the operating instructions unless you are qualified to do so.
Symbols and Their Meaning in This Manual
READ THIS MANUAL: To gain knowledge of the Link product, user must read
and understand the operator’s manual before using this product. There are
features known to the user, only if the manual is read.
The lightning flash with arrowhead symbol, within an equilateral triangle, alerts
the user to the presence of “dangerous voltage” within the product’s enclosure
that may be of sufficient magnitude to constitute a risk of electric shock to
persons.
The exclamation point within an equilateral triangle alerts the user to the
presence of important operating and maintenance (servicing) instructions in the
literatureaccompanying the appliance.
This symbol represents a protective grounding terminal. Such a terminal must
be connected to earth ground prior to making any other connections to the
equipment
The fuse symbol indicates that the fuse referenced in text must be replaced with
one having the ratings indicated.
Page 2 of 11
Always use good engineering practice. It is highly recommended to mount this
equipment in a well ventilated equipment rack. It is also recommended to use a blank
one RU spacer between mounting frames.
•
Heed all warnings on the unit and in the operating instructions.
•
Do not use this product in or near water.
•
Disconnect ac power before installing any options.
•
This product is grounded through the grounding conductor of the power cord. To
avoid electrical shock, plug the power cord into a properly wired receptacle before
connecting the product inputs or outputs.
•
Route power cords and other cables so that they are not likely to be damaged.
•
Disconnect power before cleaning. Do not use liquid or aerosol cleaners; use only
a damp cloth.
•
Dangerous voltages exist at several points in this product. To avoid personal injury,
do not touch exposed connections and components while power is on.
•
Do not wear hand jewelry or watches when troubleshooting high current circuits,
such as the power supplies.
•
During installation, do not use the door handles or front panels to lift the equipment
as they may open abruptly and injure you.
•
To avoid fire hazard, use only the specified correct type, voltage and current rating
as referenced in the appropriate parts list for this product. Always refer fuse
replacements to qualified service personnel.
•
To avoid explosion, do not operate this product in an explosive atmosphere unless
it has been specifically certified for such operation.
•
Have qualified personnel perform safety checks after any completed service.
Page 3 of 11
•
If equipped with redundant power, this unit has two power cords. To reduce the risk
of electrical shock, disconnect both power supply cords before servicing.
•
This equipment may employ laser(s). If it does, they comply with the current
construction requirements of the code of Federal regulations, title 21, chapter I,
subchapter J, sections 1010.2 and 1010.3 and sections 1040.10 and 1040.11.
•
Do not attempt to view light output of the laser transmitter, eye damage may result.
Always use an optical power meter to verify laser output.
Page 4 of 11
To prevent injury:
•
Never install telephone wiring during a lightning storm and use caution when
installing or modifying telephone lines.
•
Never install telephone jacks in wet locations unless the jack is specifically designed
for wet locations.
•
Never touch un-insulated telephone wires or terminals unless the telephone line has
been disconnected at the network interface.
Cautions
•
When installing this equipment, do not attach power cord to building surfaces.
•
To prevent damage to equipment when replacing fuses, locate and correct the
trouble that caused the fuse to blow before applying power.
•
Verify that all power supply lights are off before removing power supply or servicing
equipment.
•
Use only specified replacement parts and follow static precautions at all times when
handling this equipment.
•
Leave the back of the frame clear for air exhaust cooling and to allow room for
cabling. Slots and openings in the cabinet are provided for ventilation. Do not block
them.
•
This product should be powered on as described in the manual. To prevent
equipment damage select the proper line voltage at the ac input connector as
described in the installation documentation.
•
To prevent damage to this equipment read the instructions in this document for
proper input voltage range selection.
•
To reduce the risk of electric shock, ensure that the two power supply cords are
each plugged into a separate branch circuit.
Page 5 of 11
Circuit boards in this product are densely populated with surface mount and ASIC
components. Special tools and techniques are required to safely and effectively
troubleshoot and repair modules that use SMT or ASIC components. For this
reason, service and repair of Link products incorporating surface mount technology
are supported only on a module exchange basis. Customers should not attempt to
troubleshoot or repair modules that contain SMT components. Link assumes no
liability for damage caused by unauthorized repairs. This applies to both in- and outof-warranty products.
North American Power Supply Cords
This equipment is supplied with molded grounding plug (NEMA 5-15P) at one
end and molded grounding connector (IEC 320-C13) at the other end. Conductors
are CEE color coded, light blue (neutral), brown (line) and green/yellow (ground).
Operation of this equipment at voltages exceeding 130 VAC will require power
supply cords which comply with NEMA configurations.
International Power Supply Cord
This equipment is supplied with molded grounding connector (IEC 320-C13) at
one end and stripped connectors (50/5 mm) at the other end. Connectors are CEE
color coded, light blue (neutral), brown (line) and green/yellow (ground).
Other IEC 320-C13 type power supply cords can be used if they comply with the
safety regulations of the country in which they are installed.
Note:
This equipment has been tested and found to comply with the limits for a class
“A” digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference, in which case the
user will be required to correct the interference at his own expense.
Page 6 of 11
PORTABLE CC DECODER
MODEL PCD-88
The PCD-88 is the standard closed caption decoder for field one line 21 decoding.
The toggle switch on the left end selects CC1 or CC2 only. The GPI only turns off
the closed caption data. The power remains on and the captions are displayed
with the GPI open. The closed captions are turned off when the GPI is closed. A
3.5mm male plug is included for the remote control function.
The input video is high impedance loop through. If the video input is not looped on
to another product, the remaining BNC must be terminated with 75 ohms. One 754
ohm termination is included. The PWT-300 is included also.
Included
MODEL PCD-88 TOP
Included
Included
PCD-88 END VIEW
Page 7 of 11
PCD-85 GENERAL DESCRIPTION
The PCD-88 is a high performance closed caption decoder for the NTSC
system. It is capable of processing and displaying standard line 21 Field one
closed captions.The two channels of data are CC1 and CC2. The two channels
are selected from a toggle switch on the end of the unit. Two LED's on the end
panel indicate which CC channel is selected.
This unit can easily be placed along side a video monitor that does not have a
built-in closed caption decoder to accomplish excellent results.
A toggle switch on the end panel allows the user to select between the two
caption channels, CC1 and CC2. The PCD-88 is designed with the professional
user in mind. The required input signal is baseband video at 1 Vp-p with
caption data on line 21 of field one. There are two 75 Ω BNC composite video
outputs. The input is high impedance looping configured for single ended
operation, AC coupled, to work in all environments. The PCD-88 operates on
12VDC, or a regulated wall transformer at 12VDC. The Link Electronics model
PWT-300 power supply operates on a line voltage of 110 to 220 VAC, and is
included.
Three internal controls provide for adjustment of composite video level,
background level and character intensity.
The PCD-88 is housed in a compact and rugged portable case for reliable
performance. All Link products are backed by a ten-year warranty including
parts and labor.
Page 8 of 11
MODEL PCD-88 PORTABLE CLOSED CAPTION DECODER
SPECIFICATIONS
INPUT:
Video Level: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 Vp-p ±6dB
Impedance: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50KΩ, Bridging
Configuration: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single Ended, AC Coupled
OUTPUTS:
Number: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Two
Level: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unity
Impedance: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Ω ±1%, source terminated
Character Intensity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 IRE
Character Background: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 IRE
Caption Time Out: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Seconds
Frequency Response: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.1dB to 10MHz
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±1 dB at 20 MHZ
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -3dB at 30 MHZ
Differential Gain: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.2%
Differential Phase: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5E
Output DC Offset: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC Coupled
Hum & Noise: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >50dB
Propagation Delay: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27nS
Line Rate Tilt: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1%
Field Rate Tilt: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1%
INTERNAL CONTROLS:
Video Level: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Vp-p
Character Intensity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 IRE
Background Level: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 IRE
ENVIRONMENTAL:
Temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0E to 50EC, Ambient
Humidity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0% to 90% non-condensing
POWER: (PWT-300 Required)
Voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Volts DC, Regulated
Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 watt Typical
MECHANICAL:
Height: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4"
Width: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5"
Depth: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6"
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5oz.
Page 9 of 11
PCD-85 SETUP PROCEDURE
NOTE: YOUR UNIT HAS BEEN COMPLETELY CALIBRATED BEFORE IT WAS
SHIPPED. THERE IS NO NEED TO CALIBRATE THE PCD-88!
Page 10 of 11
PRODUCT WARRANTY
Link Electronics, Inc.
Link Electronics Inc. warrants its product to be free from defective material and
workmanship for a period of TEN-YEARS from date of shipment, including
parts and labor. This warranty excludes the HDE-3000 High Definition Closed
Caption Encoder & PCR-8200 Video Disc Recorder, note1. Labor performed at
the Link Electronics factory in Cape Girardeau, Missouri.
This warranty does not extend to products which have been subjected to
misuse, neglect, accident, incorrect wiring, alteration, improper installation, or
used in violation of instructions from Link Electronics. Link Electronics makes
no other warranties, express or implied, of merchantability, fitness for a
particular purpose, or otherwise. Link Electronics liability for any cause,
including breach of contract, breach of warranty, or negligence, with respect to
products sold by it, is limited to repair or replacement by Link Electronics, at its
sole discretion.
The product must be shipped to Link Electronics, freight costs prepaid.
Repaired or replaced equipment shall be shipped customer surface freight only,
to be paid by Link Electronics. This warranty is in lieu of all other warranties,
expressed or implied, with respect to the condition or performance of any Link
Electronics products, its merchantability, or fitness for a particular purpose.
The product warranty will be null and void, if a specific component part should
become obsolete by the manufacturer. If the component part becomes
obsolete and not available through distribution, Link Electronics, Inc will not be
responsible for repair or replacement of a Link Electronics manufactured
product.
In no event shall Link Electronics be liable for any incidental or consequential
damages, including loss of profits.
SERVICE INFORMATION
In the event that the Link Electronics equipment should fail, you should contact
the Customer Service Department and request a Return Authorization (RA)
number. At that time, the details of how the repair should be processed will be
discussed.
All inquiries relating to either parts replacement or warranty service should be
directed to: LINK ELECTRONICS, INC., 2137 Rust Avenue, Cape Girardeau,
Missouri 63703. Attention: Service Department. Phone: (573)334-4433. Fax:
(573)334-9255.
This WARRANTY supersedes all previous warranties, whether implied, written
or verbal, Date, October 1, 2005.
Note 1: See the Warranty for the HDE-3000 & PCR-8200 for the warranty
period of these product.
Page 11 of 11