Kamera DDZ3018(26)A-DN
English
Installation and Configuration
Dome Camera (Day/Night)
DDZ3018A-DN
DDZ3026A-DN
Rev. 2.0.0 / 070613
DDZ3018A-DN/DDZ3026A-DN
Copyright © Dallmeier electronic GmbH & Co.KG
All rights reserved. This document may not be copied, photocopied,
reproduced, translated, transferred to an electronic medium or converted
to a machine-readable form either whole or in part without first receiving
written permission from Dallmeier electronic GmbH & Co.KG.
We reserve the right to make technical modifications.
The manufacturer accepts no liability for damage to property or pecuniary
damages arising due to minor defects of the product or documentation,
e.g. print or spelling errors, and for those not caused by intention or gross
negligence of the manufacturer.
Dallmeier electronic GmbH & Co.KG
Cranachweg 1
D 93051 Regensburg
www.dallmeier-electronic.com
info@dallmeier-electronic.com
2
Dallmeier electronic GmbH & Co.KG
Table of contents
1
About this document .......................................................................... 5
1.1
1.2
1.3
Validity ................................................................................................... 5
Documentation on the DDZ3018A-DN ................................................... 5
Convention ............................................................................................ 5
2
For your safety .................................................................................... 7
3
General instructions ......................................................................... 11
3.1
3.2
3.3
3.4
3.5
Scope of delivery ................................................................................. 11
Transportation and packaging .............................................................. 11
Appropriate use ................................................................................... 11
Performance Features ......................................................................... 11
Warranty ............................................................................................. 12
4
Notes on operating the camera ........................................................ 13
5
Views and connection assignments ................................................ 15
6
Basic Settings ................................................................................... 17
6.1
6.2
6.3
6.4
6.5
6.6
6.7
Removing the housing base plate ........................................................ 17
Termination .......................................................................................... 18
Camera ID ........................................................................................... 18
Video Standard, Communication and Camera Setup ........................... 19
Protocol ............................................................................................... 20
Baud Rate ........................................................................................... 21
Factory settings ................................................................................... 22
7
Installation and Commissioning ...................................................... 27
7.1
7.2
7.2.1
7.2.2
7.2.3
7.2.4
7.3
7.4
Requirements at the installation site .................................................... 27
Doing the wiring ................................................................................... 27
RS-422/485 connection ....................................................................... 27
Video cable ......................................................................................... 28
Contact IN / Relay OUT Cable ............................................................. 28
Power Connection ............................................................................... 29
Installation ........................................................................................... 29
Commissioning ................................................................................... 31
8
Camera Control and Configuration via Recorder/PView ............... 33
8.1
8.2
8.2.1
8.2.2
8.2.3
Camera Control ................................................................................... 33
Configuration ....................................................................................... 34
DOME ................................................................................................. 35
Camera ............................................................................................... 38
MOTION ............................................................................................. 41
9
Camera Control and Configuration via PTZ Controller ................. 49
9.1
9.1.1
9.2
Camera control .................................................................................... 49
Shortcuts ............................................................................................. 50
Configuration ....................................................................................... 50
Dallmeier electronic GmbH & Co.KG
3
DDZ3018A-DN/DDZ3026A-DN
4
9.2.1
9.2.2
9.2.3
9.2.4
9.2.5
DOME ................................................................................................. 50
Camera ............................................................................................... 54
MOTION ............................................................................................. 57
DISPLAY ............................................................................................. 63
Shortcuts ............................................................................................. 65
A
Appendix ........................................................................................... 67
A1
A2
Menu structure .................................................................................... 67
Technical Data ..................................................................................... 69
Dallmeier electronic GmbH & Co.KG
1
1.1
About this document
Validity
This document applies to the Day/Night Dome Cameras DDZ3018ADN and DDZ3026A-DN.
It has been produced on the basis of software version 1.3 (DDZ3018ADN), 1.4 (DDZ3026A-DN), 5.6.2 (PView) and 6.0.2 (DMS 240).
The descriptions in this document apply to both cameras. For
simplification reasons, the term “DDZ3018A-DN” is thus used for
both cameras.
If text passages require distinctions to be made between the
cameras, the complete camera name will be mentioned.
1.2
Documentation on the DDZ3018A-DN
Commissioning
The Quick Guide headed "Commissioning" lists the most important
steps for the connection and commissioning of the camera.
Installation and Configuration (this document)
The document entitled "Installation and Commissioning" contains
detailed descriptions of the mounting, connection, commissioning
and configuration of the camera. General notes on the product and
technical data are additionally provided.
Storage of documentation
Store the documents in an accessible location near the product.
Keep the documents in readable condition. Pass on all documents
to each successive owner or user of the camera.
1.3
Convention
This document contains various warning words and symbols that
indicate potential sources of danger. Various symbols and formats
are used to maintain the clarity of the document.
Dallmeier electronic GmbH & Co.KG
5
DDZ3018A-DN/DDZ3026A-DN
DANGER
The warning word DANGER denotes an immediate danger that may cause death or serious
injury if it is not averted.
WARNING
The warning word WARNING denotes a possible
danger that may cause death or serious injury
if it is not averted.
CAUTION
The warning word CAUTION denotes a possible
danger that may cause minor injury if it is not
averted.
IMPORTANT
The word IMPORTANT denotes information for
preventing damage, incorrect configurations or
incorrect actions.
NOTE
A NOTE offers information on principles, special
features and efficient procedure as well as general
recommendations.
Expression
6
Expressions in bold and italics generally indicate
a control element on the device (switches or labels)
or on its user interface (buttons, menu entries).
Dallmeier electronic GmbH & Co.KG
2
For your safety
Only use this unit if it is technically in proper working order, to the
intended purpose and while keeping safety and potential dangers
in mind. Have malfunctions or damages eliminated immediately!
Appoint a professional
Installation, mounting, connection, start-up and configuration of
the unit may only be carried out by trained and authorized
professionals (installers).
Unless otherwise expressly specified, this also applies to the
maintenance, testing and repair.
Read and pay attention to the documents
Carefully and completely read the documents included in delivery.
Always pay attention to the provided instructions, notes and
warnings.
Regulations surveillance systems
The use of video and audio surveillance systems is strictly regulated
in most countries. Therefore, inform yourself on laws and regulations
that govern individual applications before using the unit. Ensure
compliance with these laws and regulations and also observe
regulations regarding data, working and environmental protection.
Regulations data protection
This unit can store data that may be subject to data protection. The
collecting, recording, processing or disclosure of such data may
be forbidden and thus have legal consequences. Therefore, inform
yourself on data protection laws and regulations that govern individual applications before using the unit. Ensure compliance with
this laws and regulations.
Do not make modifications
Do not make any modifications to the unit (neither to the software
nor the hardware) without consulting Dallmeier electronic. Improper
modifications can cause malfunctions or damages. Dallmeier
electronic accepts no liability for damages resulting from
unauthorized or improper modifications to the unit.
Dallmeier electronic GmbH & Co.KG
7
DDZ3018A-DN/DDZ3026A-DN
Protection against condensation water
If the unit is brought from a cold to a warm environment,
condensation water can form inside the unit. Short-circuits may
then lead to damage to the system. Wait up to 8 hours for the unit
to reach room temperature before starting it up.
Observe the rated voltage
The unit can be damaged or destroyed by the application of an
incorrect voltage.
The mains voltage must always match the rated voltage of the
unit. The rated voltage is specified on the rating plate of the unit.
Observe ratings
Unsuitable ambient conditions and improper installation (mainly
too high ambient temperature and insufficient ventilation) may
reduce the unit’s life cycle. Ensure compliance with the stated
operating conditions (see technical data), requirements at the
installation site and, if applicable, maintenance regulations.
Expansion components/peripheral devices
Use only expansion components conforming with the technical data
of the unit. Inappropriate peripheral devices may result in the
violation of local laws and regulations and damages to the unit.
Furthermore, the use of peripheral devices that are not tested and
approved by Dallmeier electronic results in loss of warranty. In case
of doubt, contact the sales partner responsible for your area.
Do not move while in operation
Strong vibrations can cause damage to the unit. Therefore, do not
bump the unit or move it in a jerky motion while in operation. Instruct
the cleaning personnel accordingly if necessary!
Do not open the unit
Do not open the housing of the unit. There are no components
inside the unit that require maintenance by the user. The inspection,
maintenance and repair with an open housing must only be carried
out by trained and authorized professionals (installer).
Penetration of foreign bodies and liquids
No objects or liquids may be allowed to get into the device. In this
case, immediately disconnect the unit from the power supply (pull
out the power plug). Please contact the sales partner responsible
for your area.
8
Dallmeier electronic GmbH & Co.KG
Measures to be taken in the event of damage and burnt
smell
If you notice burnt smell or formation of smoke from a unit,
immediately disconnect it from the power supply (pull out the power plug). Please contact the sales partner responsible for your
area.
Disposal
Disconnect the unit from the power supply. Remove all connected
units and system components. Return the unit to your respective
sales partner.
Dallmeier electronic GmbH & Co.KG
9
DDZ3018A-DN/DDZ3026A-DN
10
Dallmeier electronic GmbH & Co.KG
3
3.1
General instructions
Scope of delivery
1 x DDZ3018A-DN/DDZ3026A-DN
1 x Operating Instructions "Installation and Configuration"
1 x Quick Guide "Commissioning"
3 x Screws and dowels
2 x Cable with plug (alarm input and AUX OUT)
1 x Hook and screw (for optionally available weather proof housing)
3.2
Transportation and packaging
Store the original packaging for transportation at a later date.
Dallmeier electronic is not responsible for damage resulting from
unprofessional/improper transportation. The goods should only be
shipped in their original packaging. If the original packaging is no
longer available, ensure that the packaging used sufficiently protects
the unit against damage, moisture, heat and cold.
3.3
Appropriate use
The DDZ3018A-DN is a dome camera for color or b/w imaging. It
is designed for indoor as well as for outdoor use (with corresponding
weather proof housing only). The camera can be mounted on walls
and ceilings.
3.4
Performance Features
The DDZ3018A-DN/DDZ3026A-DN is a high-resolution dome
camera with 18x/26x optical zoom (12x/10x digital zoom) and a
resolution of 480 TV lines. Its light sensitivity and the day/night
function allow images with greater color neutrality and clarity of
detail, even at low light levels. Designed to be free from glare, the
camera permits detailed recognition even against extreme back
lighting. Further highlights include, amongst others, the panning
speed of max. 390°/sec., 248 programmable preset positions, 8
programmable tours and 4 patterns, 8 dynamic privacy zones as
well as 8 programmable alarm inputs and 4 outputs.
Dallmeier electronic GmbH & Co.KG
11
DDZ3018A-DN/DDZ3026A-DN
NOTE
For detailed information, please refer to the
Technical Data sheet in the appendix.
3.5
Warranty
The warranty period is 36 months.
The terms and conditions valid at the signing of the contract apply.
12
Dallmeier electronic GmbH & Co.KG
4
Notes on operating the camera
‰ The camera is operated at 24V AC.
‰ If the camera or the cables connected to the camera are located
near sources of strong radiation, the video picture may be
distorted.
‰ The camera is equipped with automatic gain control (AGC). In
low light the picture may be altered (e.g. noise). This is not a
camera malfunction.
‰ The quality of the video picture depends on the lighting and the
monitor used to display the video picture.
‰ Automatic white balance depends on the lighting used and can
cause color distortions in artificial light.
‰ Poor lighting can lead to faulty white balance.
Dallmeier electronic GmbH & Co.KG
13
DDZ3018A-DN/DDZ3026A-DN
14
Dallmeier electronic GmbH & Co.KG
5
Views and connection assignments
1 Movable dome
2 Camera module
3 Housing base plate
4 Securing screw
Fig. 5-1
Connection assignment (housing base plate)
1 DIP switches: video standard,
communication, camera setup,
protocol, baud rate, default
2 DIP switches: Camera ID
3 DIP switches: Termination
4 Alarm 2
5 RS-422/485 connection
6 Power supply 24 V AC
7 Alarm 1
8 Video cable
Fig. 5-2
Dallmeier electronic GmbH & Co.KG
15
DDZ3018A-DN/DDZ3026A-DN
16
Dallmeier electronic GmbH & Co.KG
6
Basic Settings
Make the settings described in the following by means of the
switches in the housing base plate before connecting and
commissioning the camera.
6.1
Removing the housing base plate
¾ Carefully turn the upper part counter-clockwise until you cannot
turn it anymore. Pay attention to the marking.
¾ Remove the upper part from the housing base plate.
Fig. 6-2
Fig. 6-1
Fig. 6-3
Dallmeier electronic GmbH & Co.KG
17
DDZ3018A-DN/DDZ3026A-DN
6.2
Termination
If several cameras are connected in series to a control panel or
recorder, you have to terminate the last camera of this chain.
Improper termination may result in erroneous control signals. The
overall length of the communication cable should not exceed 1.2
km.
Termination ON
Termination OFF
Fig. 6-4
6.3
Camera ID
¾ Assign the camera an ID number by means of the rotary switches.
Fig. 6-5
Example: S3=1, S2=2, S1=8 corresponds to ID number 128.
18
Dallmeier electronic GmbH & Co.KG
NOTE
Write down the ID number of each camera. Ensure
that you do not assign an ID number several times.
6.4
Video Standard, Communication and Camera
Setup
Set the video standard (as stated in the order), interface and camera
setup by means of the S4 DIP switches.
Fig. 6-6
S4
Video Standard
1
On
PAL
Off
NTSC
S4
Communication
2
On
RS-422
Off
RS-485
S4
Camera Setup
3
4
Off
Off
Auto detection
On
Off
Reserved
Off
On
Reserved
On
On
Reserved
Dallmeier electronic GmbH & Co.KG
19
DDZ3018A-DN/DDZ3026A-DN
6.5
Protocol
Set the protocol by means of the S5 DIP switches.
Fig. 6-7
S5
20
Protocol
1
2
3
4
Off
Off
Off
Off
Auto detection (No Parity)
On
Off
Off
Off
Auto detection (Even Parity)
Off
On
Off
Off
Pelco P
On
On
Off
Off
Reserviert
Off
Off
On
Off
Honeywell
On
Off
On
Off
Pelco D
Off
On
On
Off
VICON
On
On
On
Off
American Dynamics, RS-422
Off
Off
Off
On
Dynacolor
On
Off
Off
On
Reserviert
Off
On
Off
On
Reserviert
On
On
Off
On
Reserviert
Off
Off
On
On
Reserviert
On
Off
On
On
Reserviert
Off
On
On
On
Reserviert
On
On
On
On
H/W Factory default
Dallmeier electronic GmbH & Co.KG
6.6
Baud Rate
Set the baud rate by means of the S6 DIP switches.
Fig. 6-8
S6
Baud Rate
1
2
3
Off
Off
Off
2400 bps
Off
Off
On
4800 bps
Off
On
Off
9600 bps
Off
On
On
19200 bps
On
Off
Off
38400 bps
On
Off
On
57600 bps
On
On
Off
115200 bps
On
On
On
230400 bps
S6
Extended ID
4
On
0 - 999
Off
1000 - 3999
Dallmeier electronic GmbH & Co.KG
21
DDZ3018A-DN/DDZ3026A-DN
6.7
Factory settings
Entries in bold and italics show the default settings of the camera.
PAL
S4
Video Standard
1
On
PAL
Off
NTSC
S4
Communication
2
On
RS-422
Off
RS-485
S4
Camera Setup
3
4
Off
Off
Auto detection
On
Off
Reserved
Off
On
Reserved
On
On
Reserved
NTSC
S4
Video Standard
1
On
PAL
Off
NTSC
S4
Communication
2
On
RS-422
Off
RS-485
S4
22
Camera Setup
3
4
Off
Off
Auto detection
On
Off
Reserved
Off
On
Reserved
On
On
Reserved
Dallmeier electronic GmbH & Co.KG
PAL
S5
Protocoll
1
2
3
4
Off
Off
Off
Off
Auto detection (No Parity)
On
Off
Off
Off
Auto detection (Even Parity)
Off
On
Off
Off
Auto detection (Odd Parity)
On
On
Off
Off
Reserved
Off
Off
On
Off
HW
On
Off
On
Off
P-D
Off
On
On
Off
VCN
On
On
On
Off
SNM
Off
Off
Off
On
DNC
On
Off
Off
On
KTL
Off
On
Off
On
PS
On
On
Off
On
SAE
Off
Off
On
On
SAT
On
Off
On
On
VL
Off
On
On
On
DMD
On
H/W Factory default
On
On
Dallmeier electronic GmbH & Co.KG
On
23
DDZ3018A-DN/DDZ3026A-DN
NTSC
S5
24
Protocol
1
2
3
4
Off
Off
Off
Off
Auto detection (No Parity)
On
Off
Off
Off
Auto detection (Even Parity)
Off
On
Off
Off
Auto detection (Odd Parity)
On
On
Off
Off
Reserved
Off
Off
On
Off
HW
P-D
On
Off
On
Off
Off
On
On
Off
VCN
On
On
On
Off
SNM
Off
Off
Off
On
DNC
On
Off
Off
On
KTL
Off
On
Off
On
PS
On
On
Off
On
SAE
Off
Off
On
On
SAT
On
Off
On
On
VL
Off
On
On
On
DMD
On
On
On
On
H/W Factory default
Dallmeier electronic GmbH & Co.KG
PAL
S6
Baud Rate
1
2
3
Off
Off
Off
2400 bps
Off
Off
On
4800 bps
Off
On
Off
9600 bps
Off
On
On
19200 bps
On
Off
Off
38400 bps
On
Off
On
57600 bps
On
On
Off
115200 bps
On
On
On
230400 bps
S6
Extended ID
4
On
0-999
Off
1000-3999
NTSC
S6
Baud Rate
1
2
3
Off
Off
Off
2400 bps
Off
Off
On
4800 bps
Off
On
Off
9600 bps
Off
On
On
19200 bps
On
Off
Off
38400 bps
On
Off
On
57600 bps
On
On
Off
115200 bps
On
On
On
230400 bps
S6
Extended ID
4
On
0-999
Off
1000-3999
Dallmeier electronic GmbH & Co.KG
25
DDZ3018A-DN/DDZ3026A-DN
26
Dallmeier electronic GmbH & Co.KG
7
Installation and Commissioning
7.1
Requirements at the installation site
The DDZ3018A-DN is designed for indoor use. If used outdoors,
the camera has to be mounted into a corresponding weather proof
housing.
Unfavorable local conditions may shorten the life of the product or
lead to malfunctions.
Do not install/operate the camera in places:
z with large scale dust and dirt
z with steam or oil vapors (e.g. kitchen)
z with direct sunlight
z with improper ambient temperatures (see technical data)
z near sources of strong radiation, i.e. X-rays, radio transmitters
or magnetic fields
z with corrosive surroundings (e.g. gases or salt water).
7.2
Doing the wiring
Connect all necessary cables before installing the camera to the
wall/ceiling.
7.2.1
RS-422/485 connection
¾ Connect a DNI-1 or control panel (PTZ Controller) to this
connection.
The DNI-1 is necessary to configure and control the camera via a
recorder/PView.
NOTE
For detailed information, please refer to the
respective user manuals.
Dallmeier electronic GmbH & Co.KG
27
DDZ3018A-DN/DDZ3026A-DN
7.2.2
Video cable
¾ Connect the video cable.
WARNING
Danger of death from lightening strike!
Do not connect the video cable during a thunderstorm.
7.2.3
Contact IN / Relay OUT Cable
¾ Connect the contact IN / relay OUT cables, if applicable.
Fig. 7-1
Pin assignment
Alarm 2
Alarm 1
28
1
COM
A1
COMB
2
NC A
2
NC B
3
NO A
A3
NO B
4
GND
4
GND
5
ALARM4
5
ALARM8
6
ALARM3
6
ALARM7
7
ALARM2
7
ALARM6
8
ALARM1
8
ALARM5
Dallmeier electronic GmbH & Co.KG
7.2.4
Power Connection
WARNING
Danger of death from electric shock!
The power supply unit must not be connected to
the power supply when connecting it to the camera.
¾ Connect the power supply unit to the camera.
IMPORTANT
Possible damage to the camera caused by an
inadequate power supply unit.
If used in North America make sure to use a ULcertified, limited-power Class 2 power supply unit
(24V AC, 1,000 mA) for the camera power supply.
7.3
Installation
1. Mark the drill holes for the fixing screws using the housing base
plate.
Fig. 7-2
2. Drill the holes for the fixing screws.
3. Screw the housing base plate to the wall/ceiling.
4. Attach the upper part to the housing base plate. Pay attention to
the marking.
Dallmeier electronic GmbH & Co.KG
29
DDZ3018A-DN/DDZ3026A-DN
Fig. 7-3
5. Carefully turn the upper part counter-clockwise until you cannot
turn it anymore. Pay attention to the marking.
Fig. 7-4
6. Screw in the securing screw.
Fig. 7-4
30
Dallmeier electronic GmbH & Co.KG
7.4
Commissioning
CAUTION
Danger of injury from the camera falling down.
Before initial startup, make sure that the dome and
the housing base plate are securely mounted.
¾ Connect the power supply unit to the power supply.
The camera is ready for operation after a short selftest.
Dallmeier electronic GmbH & Co.KG
31
DDZ3018A-DN/DDZ3026A-DN
32
Dallmeier electronic GmbH & Co.KG
8
Camera Control and Configuration via
Recorder/PView
The camera must be defined as controllable both on the recorder
and in PView to control and/or configure it. The protocols to be
used are Cam_Pelco4 for the DNI and Dallmeier in PView.
NOTE
For detailed information, please refer to the respective
user manuals.
8.1
Camera Control
¾ Click on the corresponding camera button in the recorder GUI
or PView to display the camera image.
Fig. 8-1
¾ Click on the Camera control button in the main panel.
Fig. 8-2
The control panel for the camera will be displayed.
Dallmeier electronic GmbH & Co.KG
33
DDZ3018A-DN/DDZ3026A-DN
2 3 4
Fig. 8-3
1
5
6
7 8
1 Camera control
2 Control buttons
3 Zoom in
4 Zoom out
5 Focus out
6 Focus in
7 Open camera menu
8 Close camera menu
NOTE
For detailed information on how to control the camera
via the recorder / PView, please refer to the respective
user manuals.
8.2
Configuration
MAIN MENU
→
DOME
CAMERA
→
MOTION
→
DISPLAY
→
CLEAR DATA
→
EXIT
→
SELECT → LEFT/RIGHT → SUB MENU
¾ Click on Open camera
menu (7) in the main panel
to call up the main menu
of the camera.
¾ Click on the control buttons
Up (c ) or Down (d ) to
select a menu item.
¾ Click on the control button Right (f) to call up a respective
submenu, to change a setting or to execute a command.
¾ Select EXIT or SAVE AND EXIT to save the settings and to
leave the respective menu.
34
Dallmeier electronic GmbH & Co.KG
8.2.1
DOME
DOME MENU
TITLE SET
FLIP
SPEED
RUNNING RANGE
TILT OVER ANGLE
POWER UP ACTION
HOME
SYSTEM INFORMATION
FACTORY
EXIT
SELECT → LEFT/RIGHT
:
:
:
→
ON
FAST
→
→
OFF
→
→
TITLE SET
The CAMERA TITLE menu
allows you to assign a name
to the camera that will be
displayed in the video image.
CAMERA TITLE
TITLE : CAMERA
SAVE AND EXIT
SELECT → LEFT/RIGHT
¾ Click on Zoom in (3) or Zoom out (4) to enter the characters.
¾ Click on f to activate the next position.
FLIP
DOME MENU
TITLE SET
FLIP
SPEED
RUNNING RANGE
TILT OVER ANGLE
POWER UP ACTION
HOME
SYSTEM INFORMATION
FACTORY
EXIT
SELECT → LEFT/RIGHT
Dallmeier electronic GmbH & Co.KG
:
:
:
→
ON
FAST
→
→
OFF
→
→
Set FLIP to ON to enable the
camera to automatically turn
180° in the 90° tilt position.
35
DDZ3018A-DN/DDZ3026A-DN
SPEED
DOME MENU
TITLE SET
FLIP
SPEED
RUNNING RANGE
TILT OVER ANGLE
POWER UP ACTION
HOME
SYSTEM INFORMATION
FACTORY
EXIT
SELECT → LEFT/RIGHT
:
:
:
→
ON
FAST
→
→
OFF
→
→
Choose between SLOW, MID
and FAST to set the speed of
the pan/tilt head.
Panning Range
PAN RANGE SETUP
RIGHT LIMIT
LEFT LIMIT
ENABLE
SWAP RIGHT/LEFT
SAVE AND EXIT
SELECT → LEFT/RIGHT
:
:
:
000:0
000:0
OFF
The PAN RANGE SETUP
menu allows you to define a
specific pan range beyond
whose boundaries the camera
cannot be panned.
¾ Select RIGHT LIMIT and click on Zoom in (3).
¾ Click on e f to move the camera to the right boundary of the
pan range.
¾ Click on Focus out (5) to save the position.
¾ Proceed analogously for the LEFT LIMIT.
¾ Set ENABLE to ON to activate the limitation of the pan range.
¾ Select SWAP RIGHT/LEFT to swap the left and right limit.
TILT OVER ANGLE
VIEW ANGLE SETUP
TILT OVER ANGLE
SAVE AND EXIT
SELECT → LEFT/RIGHT
:
ON
The VIEW ANGLE SETUP
menu allows you to define the
tilt range of the camera.
¾ Set TILT OVER ANGLE to ON, W/O BUBBLE or WITH
BUBBLE.
36
Dallmeier electronic GmbH & Co.KG
POWER UP ACTION
DOME MENU
TITLE SET
FLIP
SPEED
RUNNING RANGE
TILT OVER ANGLE
POWER UP ACTION
HOME
SYSTEM INFORMATION
FACTORY
EXIT
SELECT → LEFT/RIGHT
:
:
:
→
ON
FAST
→
→
OFF
→
→
If you set POWER UP ACTION to ON the camera
memorizes its last position
and moves back to it after a
power failure.
HOME
HOME FUNCTION
FUNCTION
NUMBER
TIME
OPERATION
SAVE AND EXIT
SELECT → LEFT/RIGHT
:
:
:
:
PRESET
--010 SEC
OFF
The HOME FUNCTION menu
allows you to define the home
position of the camera.
The home position is the
position the camera returns to
after a certain period of
inactivity.
The home position can be a single camera position (Preset) or a
specific tour (Pattern, Autoscan, Tour).
The position or tour must be previously defined in the MOTION
menu (section 8.2.3).
¾ Set FUNCTION to PRESET, PATTERN, AUTOSCAN or TOUR.
¾ Set the NUMBER of the position or tour.
¾ Set the TIME after which the camera is to move to its home
position.
¾ Set OPERATION to ON to activate the settings.
SYSTEM INFORMATION
SYSTEM INFORMATION
CAMERA TYPE
H/W VERSION
ROM VERSION
PROTOCOL
BAUDRATE
EXIT
SELECT → LEFT/RIGHT
Dallmeier electronic GmbH & Co.KG
:
480CP
:
V1.2
:
V1.3
:
D
: 2400BPS
The SYSTEM INFORMATION
menu contains information
about the camera.
37
DDZ3018A-DN/DDZ3026A-DN
FACTORY
FACTORY DEFAULT
ARE YOU SURE?
YES : ZOOM, NO : NEAR
(Y/N)
The FACTORY DEFAULT
menu allows you to reset the
DOME MENU settings to
default.
¾ Click on Zoom in (3) to reset the settings.
¾ Click on Focus in (6) to leave the menu without resetting the
settings.
8.2.2
Camera
CAMERA MENU
→
FOCUS
→
WB
→
AE
→
LINE LOCK
BLC
:
OFF
SHARPNESS
:
9
:
OFF
D. ZOOM
→
DAY NIGHT
CAMERA DEFAULT
STABILIZER
:
OFF
SAVE AND EXIT
SELECT → LEFT/RIGHT → SUB MENU
DDZ3026A-DN only
FOCUS
FOCUS SETUP
MODE
AF SENSITIVITY
EXIT
SELECT → LEFT/RIGHT
:
:
MANUAL
HIGH
The FOCUS SETUP menu
allows you to choose between
automatic (AUTO) and MANUAL focus.
In addition, you can set the
sensitivity of the focus (AF
SENSITIVITY).
WB (White balance)
WB SETUP
MODE
R GAIN
B GAIN
EXIT
SELECT → LEFT/RIGHT
38
:
:
AUTO
208
170
The WB SETUP menu allows
you to set the white balance
and thus adapt the color
temperature to the prevailing
light conditions.
Dallmeier electronic GmbH & Co.KG
Automatic white balance
¾ Depending on the scenario, set MODE to AUTO, INDOOR,
OUTDOOR, ONE PUSH or ATW.
Manual white balance
¾ Set MODE to MANUAL to manually perform the white balance.
AE
AE SETUP
MODE
: FULL AUTO
SLOW SHUTTER
:
AUTO
IRIS
:
F9.6
GAIN
:
0DB
BRIGHT
:
06
:
1/60
SHUTTER
EXIT
SELECT → LEFT/RIGHT
The AE SETUP menu allows
you to adapt the camera’s
exposure parameters to the
prevailing
scenario.
Depending on the selected
mode, single parameters such
as IRIS, SHUTTER etc. can be
set additionally.
¾ Set MODE to FULL AUTO, MANUAL, IRIS PRIO, SHUTTER
PRIO or BRIGHT.
¾ Set single parameters, if applicable.
LINE LOCK
LINE LOCK SETUP
MODE
: INTERNAL
PHASE
:
004
EXIT
→
SELECT
LEFT/RIGHT
The LINE LOCK SETUP menu
allows you to set the
synchronization (INTERNAL /
EXTERNAL) and to adjust the
phase.
BLC (backlight compensation)
CAMERA MENU
→
FOCUS
→
WB
→
AE
→
LINE LOCK
BLC
:
ON
SHARPNESS
:
9
:
OFF
D. ZOOM
→
DAY NIGHT
CAMERA DEFAULT
STABILIZER
:
OFF
SAVE AND EXIT
SELECT → LEFT/RIGHT → SUB MENU
Dallmeier electronic GmbH & Co.KG
Set BLC to ON to prevent the
object as far as possible from
being blanked when recording
against backlight.
DDZ3026A-DN only
39
DDZ3018A-DN/DDZ3026A-DN
SHARPNESS
CAMERA MENU
→
FOCUS
→
WB
→
AE
→
LINE LOCK
BLC
:
ON
SHARPNESS
:
9
:
OFF
D. ZOOM
→
DAY NIGHT
CAMERA DEFAULT
STABILIZER
:
OFF
SAVE AND EXIT
SELECT → LEFT/RIGHT → SUB MENU
Set the desired
sharpness.
image
DDZ3026A-DN only
D. ZOOM
CAMERA MENU
→
FOCUS
→
WB
→
AE
→
LINE LOCK
BLC
:
ON
SHARPNESS
:
9
:
OFF
D. ZOOM
→
DAY NIGHT
CAMERA DEFAULT
STABILIZER
:
OFF
SAVE AND EXIT
SELECT → LEFT/RIGHT → SUB MENU
Set the desired zoom factor for
the digital zoom.
DDZ3026A-DN only
DAY/NIGHT
The DAY NIGHT SETUP
menu allows you to choose
MODE
: AUTO
between automatic and
LOCAL CONTROL
:
OFF
manual activation of the day /
EXIT
SELECT → LEFT/RIGHT
night mode.
During night mode images are
displayed and recorded in
black-and-white.
¾ If you set MODE to AUTO the camera automatically switches to
night mode at a certain point in time.
¾ If you set MODE to MANUAL and LOCAL CONTROL to ON the
camera immediately switches to night mode regardless of the
prevailing light conditions.
¾ Set MODE to MANUAL and LOCAL CONTROL to OFF to
deactivate the night mode.
DAY NIGHT SETUP
40
Dallmeier electronic GmbH & Co.KG
CAMERA DEFAULT
CAMERA DEFAULT
ARE YOU SURE?
YES : ZOOM, NO : NEAR
(Y/N)
The CAMERA DEFAULT
menu allows you to reset the
CAMERA MENU settings to
default.
¾ Click on Zoom in (3) to reset the settings.
¾ Click on Focus in (6) to leave the menu without resetting the settings.
STABILIZER
CAMERA MENU
→
FOCUS
→
WB
→
AE
→
LINE LOCK
BLC
:
ON
SHARPNESS
:
9
:
OFF
D. ZOOM
→
DAY NIGHT
CAMERA DEFAULT
STABILIZER
:
OFF
SAVE AND EXIT
SELECT → LEFT/RIGHT → SUB MENU
8.2.3
Set STABILIZER to ON to
activate the image stabilization.
DDZ3026A-DN only
MOTION
MOTION MENU
PRESET
TOUR
SCAN
PATTERN
ALARM
EXIT
SELECT → LEFT/RIGHT
→
→
→
→
→
→
PRESET
PRESET MENU
PRESET NO:001
: UNDEFINE
LABEL
:
PRESET
POSITION
:
NONE
FOCUS
:
MANUAL
IRIS
:
AUTO
:
OFF
BLC
CLEAR
SAVE AND EXIT
SELECT → LEFT/RIGHT/TELE/WIDE
Dallmeier electronic GmbH & Co.KG
The PRESET menu allows
you to save 248 camera
positions (presets).
Presets can be called by
means of the PTZ controller
or be used as home position,
alarm position or for defining
a tour.
41
DDZ3018A-DN/DDZ3026A-DN
Saving a preset
¾ Select a preset (number) in the first line.
¾ Select LABEL to assign a name to the preset.
Click on Zoom in (3) or Zoom out (4) to enter the characters.
Click on f to activate the next position.
¾ Select POSITION and click on Zoom in (3).
Use the control buttons to move the camera to the desired position.
Click on Focus out (5) to save the position.
¾ Set FOCUS and IRIS to AUTO or MANUAL.
¾ Set BLC to ON or OFF.
Deleting a preset
CLEAR PRESET
ARE YOU SURE?
YES : ZOOM, NO : NEAR
(Y/N)
¾ Select CLEAR and then
Zoom in (3) to delete the
preset.
Click on Focus in (6) to leave the menu without resetting the settings.
Calling a preset
Use the PTZ Controller to directly call a saved preset.
TOUR
TOUR MENU
TOUR 01
:
LABEL
:
TOUR EDIT
CLEAR
SAVE AND EXIT
SELECT → LEFT/RIGHT
UNDEFINE
TOUR 01
The TOUR menu allows you
to define and save 8 tours.
Tours can be started by means
of the PTZ controller or be
used as home position.
The single positions of a tour can be previously defined presets or
other tours or ranges (Pattern, Scan, Tour).
Defining and saving a tour
¾ Select a tour in the first line.
¾ Select LABEL to assign a name to the tour.
Click on Zoom in (3) or Zoom out (4) to enter the characters.
Click on f to activate the next position.
¾ Select Tour EDIT.
42
Dallmeier electronic GmbH & Co.KG
NO
FUNC
NUMBER S DWEL
01
PRST
01
F
3
02
PRST
02
F
3
03
------04
------SET (FAR) DEL (NEAR)
→
SELECT
LEFT/RIGHT/TELE/WIDE
¾ Define the first position of
the tour in the FUNC and
NUMBER columns.
¾ Set the camera’s motion
speed in the S column.
¾ Set the dwell time for the first position in the DWEL column.
¾ Proceed analogously for all other positions of the tour.
¾ Click on Focus out (5) after defining all positions.
Deleting a tour
CLEAR TOUR
ARE YOU SURE?
YES : ZOOM, NO : NEAR
(Y/N)
¾ Select CLEAR and then
Zoom in (3) to delete the
tour.
¾ Click on Focus in (6) to leave the menu without deleting the
tour.
Starting the tour
Use the PTZ Controller to start a tour.
SCAN
SCAN MENU
SCAN NO:001
:
UNDEFINE
LABEL
: AUTOSCAN 01
START
:
NONE
END
:
NONE
SPEED
:
3
:
CCW
DIR.
SWAP
:
OFF
CLEAR
SAVE AND EXIT
SELECT → LEFT/RIGHT/TELE/WIDE
The SCAN menu allows you
to define and save 16 individual pan ranges.
Pan ranges can be scanned
by means of the PTZ
controller or be used as home
position or single position for
a tour.
Defining and saving a pan range
¾ Select a pan range in the first line.
¾ Select LABEL to assign a name to the pan range.
Click on Zoom in (3) or Zoom out (4) to enter the characters.
Dallmeier electronic GmbH & Co.KG
43
DDZ3018A-DN/DDZ3026A-DN
Click on f to activate the next position.
¾ Select START and click on Zoom in (3).
Use the control buttons to move the camera to the first position
of the pan range.
Click on Focus out (5) to save the position.
¾ Proceed analogously for the second position (END).
¾ Set the camera’s motion speed in the SPEED column.
¾ Set the direction (DIR.) with which the camera is to scan the
pan range (CW = clockwise, CCW = counter-clockwise).
¾ Set SWAP to ON to swap the two position coordinates.
Deleting the pan range
CLEAR SCAN
ARE YOU SURE?
YES : ZOOM, NO : NEAR
(Y/N)
¾ Select CLEAR and then
Zoom in (3) to delete the
pan range.
¾ Click on Focus in (6) to leave the menu without deleting the pan
range.
Scanning a pan range
Use the PTZ Controller to scan a pan range.
PATTERN
PATTERN MENU
PATTERN NO:001
:
UNDEFINE
LABEL
:
PATTERN 01
RECORD SAVE
:
000 SEC
→
PLAY
:
CLEAR
SAVE AND EXIT
SELECT → LEFT/RIGHT
The PATTERN menu allows
you to define and save 4 individual tours (patterns).
Unlike a tour defined in the
TOUR menu, a pattern is a
recorded sequential series of
pan, tilt, zoom and focus
movements of the camera.
That way a smoother and more thorough type of tour can be
realized.
These individual patterns can be run by means of the PTZ controller
or be used as home position.
44
Dallmeier electronic GmbH & Co.KG
Defining and saving a pattern
¾ Select a pattern in the first line.
¾ Select LABEL to assign a name to the pattern.
Click on Zoom in (3) or Zoom out (4) to enter the characters.
Click on f to activate the next position.
¾ Select RECORD SAVE and click on f.
¾ Use the control, zoom and focus buttons to define the pattern.
¾ Click on Focus out (5) to save the pattern.
¾ Select PLAY to play back the saved pattern for checking
purposes.
Deleting a pattern
CLEAR PATTERN
ARE YOU SURE?
YES : ZOOM, NO : NEAR
(Y/N)
¾ Select CLEAR and then
Zoom in (3) to delete the
pattern.
¾ Click on Focus in (6) to leave the menu without deleting the
pattern.
Running a pattern
Use the PTZ Controller to run a pattern.
ALARM
ALARM MENU
ALARM NO:001
:
MOTION
:
PRIORITY
:
ALARM IN
:
ALARM OUT
:
:
HOLD
LATCH
:
SAVE AND EXIT
SELECT → LEFT/RIGHT
UNDEFINE
OFF
3
OFF
OFF
001 SEC
OFF
The ALARM menu allows you
to determine previously
defined presets the camera
automatically moves to if an
alarm is triggered (relay is
switched).
¾ Select an alarm in the first line.
¾ Select next to MOTION the preset that is to be called if an alarm
is triggered.
Dallmeier electronic GmbH & Co.KG
45
DDZ3018A-DN/DDZ3026A-DN
¾ Assign a PRIORITY to the preset.
¾ Select the corresponding relays for ALAMR IN and ALARM OUT.
¾ Select the time for HOLD to elapse after the end of an alarm
until the camera can be controlled again.
¾ If you set LATCH to ON the alarm (preset) number will be
permanently displayed in the video image.
DISPLAY
DISPLAY MENU
→
→
→
→
→
LANGUAGE
PRIVACY ZONE
NORTH DIRECTION
AREA
DISPLAY ON/OFF
EXIT
SELECT → LEFT/RIGHT
LANGUAGE
LANGUAGE SETUP
:
LANGUAGE
SAVE AND EXIT
SELECT → LEFT/RIGHT
ENGLISH
There are currently no settings
to modify in the LANGUAGE
SETUP menu.
The default language is English.
PRIVACY ZONE
PRIVACY ZONE SETUP
NO.
TITLE
01
NONE
02
NONE
03
NONE
04
NONE
05
NONE
06
NONE
07
NONE
08
NONE
SAVE AND EXIT
SELECT → LEFT/RIGHT
METHOD
MASK
MASK
MASK
MASK
MASK
MASK
MASK
MASK
The PRIVACY ZONE SETUP
menu allows you to mask
certain image areas.
¾ Select a number and click
on Zoom in (3).
¾ Use the control buttons to
move the camera to the
image area you want to
mark.
¾ Click on Focus out (5) to
save the image area.
46
Dallmeier electronic GmbH & Co.KG
¾ Click on f to assign a name to the privacy zone.
Click on Zoom in (3) or Zoom out (4) to enter the characters.
Click on f to activate the next position.
¾ Select the desired METHOD to mark the defined image area.
¾ Proceed analogously for further privacy zones.
NORTH DIRECTION
NORTH DIRECTION
:
POSITION
SAVE AND EXIT
SELECT → LEFT/RIGHT
000.0
The NORTH DIRECTION
menu allows you to direct the
camera towards north and to
save this position. The
cardinal points will then be
displayed in the video image.
¾ Click on Zoom in (3).
¾ Move the camera towards north using the control buttons.
¾ Click on Focus out (5) to save the position.
NOTE
Open the DISPLAY ON/OFF menu and activate
the display of the cardinal points (NORTH
DIRECTION : ON).
AREA
AREA TITLE
AREA NO : 001
:
LABEL
:
START
:
STOP
:
CLEAR
SAVE AND EXIT
SELECT → LEFT/RIGHT
UNDEFINE
-----
The AREA TITLE menu
allows you to assign a name
to the area between two
camera positions. This name
is displayed in the video image
as long as the camera moves
between the two defined
positions.
¾ Select an area in the first line.
¾ Select LABEL to assign a name to the area.
Click on Zoom in (3) or Zoom out (4) to enter the characters.
Click on f to activate the next position.
¾ Select START and click on f.
Dallmeier electronic GmbH & Co.KG
47
DDZ3018A-DN/DDZ3026A-DN
¾ Use the control buttons to move the camera to the first position
of the area.
¾ Click on Focus out (5) to save the position.
¾ Proceed analogously for the second position (STOP).
¾ Select CLEAR and then Zoom in (3) to delete the area.
Click on Focus in (6) to leave the menu without deleting the
area.
CLEAR AREA
ARE YOU SURE?
YES : ZOOM, NO : NEAR
(Y/N)
DISPLAY ON/OFF
DISPLAY ON/OFF MENU
TITLE
:
PRESET
:
TOUR
:
AREA
:
ALARM
:
SCAN
:
PATTERN
:
POSITION
:
NORTH DIRECTION
:
SAVE AND EXIT
SELECT → LEFT/RIGHT
ON
ON
ON
ON
ON
ON
ON
ON
ON
The DISPLAY ON/OFF menu
allows you to determine the
information being displayed in
the video image.
¾ Select the desired item and
choose between ON and
OFF.
CLEAR DATA
CLEAR DATA
PRESET
TOUR
AREA
ALARM
SCAN
PATTERN
EXIT
SELECT → LEFT/RIGHT
The CLEAR DATA menu
allows you to reset single
settings to default.
¾ Select the desired menu
item and click on f.
¾ Click on Zoom in (3) to
reset the settings.
¾ Click on Focus in (6) to
leave the menu without
resetting the settings.
48
Dallmeier electronic GmbH & Co.KG
9
9.1
Camera Control and Configuration via PTZ
Controller
Camera control
Use the joystick to control the camera and to zoom in or out.
The camera’s aperture and focus are set by means of the respective
keys.
Shortcuts allow previously defined presets to be directly called or
tours to be started.
1 – Joystick
2 – Wide/Zoom (Zoom out)
3 – TELE (Zoom in)
4 – Near/Focus (Focus in)
5 – FAR (Focus out)
6 – IRIS Close (Lessen iris)
7 – IRIS Open (Widen iris)
8 – Display
NOTE
For detailed information on how to use the PTZ
Controller, please refer to the PTZ Controller user
manual.
Dallmeier electronic GmbH & Co.KG
49
DDZ3018A-DN/DDZ3026A-DN
9.1.1
9.2
Shortcuts
Function
Shortcut
Calling a preset
No. of preset + F1
Starting a tour
No. of tour + F3
Scanning a range
No. of pan range + F4
Running a pattern
No. of pattern + F5
Home position
91 + F1
Continuous panning
92 + F1
Configuration
MAIN MENU
→
DOME
CAMERA
→
MOTION
→
DISPLAY
→
CLEAR DATA
→
EXIT
→
SELECT → LEFT/RIGHT → SUB MENU
¾ Hold the 1 and menu
button down for approx. 3
seconds to call up the main
menu of the camera.
¾ Use the joystick to select a
menu item.
¾ Move the joystick to the right to call up a respective submenu,
change a setting or to execute a command.
¾ Select EXIT or SAVE AND EXIT to save the settings and to
leave the respective menu.
9.2.1
DOME
DOME MENU
TITLE SET
FLIP
SPEED
RUNNING RANGE
TILT OVER ANGLE
POWER UP ACTION
HOME
SYSTEM INFORMATION
FACTORY
EXIT
SELECT → LEFT/RIGHT
50
:
:
:
→
ON
FAST
→
→
OFF
→
→
Dallmeier electronic GmbH & Co.KG
TITLE SET
The CAMERA TITLE menu
allows you to assign a name
to the camera that will be
displayed in the video image.
CAMERA TITLE
TITLE : CAMERA
SAVE AND EXIT
SELECT → LEFT/RIGHT
¾ Turn the joystick to enter the characters.
¾ Move the joystick to the right to activate the next position.
FLIP
DOME MENU
TITLE SET
FLIP
SPEED
RUNNING RANGE
TILT OVER ANGLE
POWER UP ACTION
HOME
SYSTEM INFORMATION
FACTORY
EXIT
SELECT → LEFT/RIGHT
:
:
:
→
ON
FAST
→
→
OFF
→
→
Set FLIP to ON to enable the
camera to automatically turn
180° in the 90° tilt position.
SPEED
DOME MENU
TITLE SET
FLIP
SPEED
RUNNING RANGE
TILT OVER ANGLE
POWER UP ACTION
HOME
SYSTEM INFORMATION
FACTORY
EXIT
SELECT → LEFT/RIGHT
Dallmeier electronic GmbH & Co.KG
:
:
:
→
ON
FAST
→
→
OFF
→
→
Choose between SLOW, MID
and FAST to set the speed of
the pan/tilt head.
51
DDZ3018A-DN/DDZ3026A-DN
PLANNING RANGE
PAN RANGE SETUP
RIGHT LIMIT
LEFT LIMIT
ENABLE
SWAP RIGHT/LEFT
SAVE AND EXIT
SELECT → LEFT/RIGHT
:
:
:
000:0
000:0
OFF
The PAN RANGE SETUP
menu allows you to define a
specific pan range beyond
whose boundaries the camera
cannot be panned.
¾ Select RIGHT LIMIT and press the TELE key (3).
¾ Use the joystick to move the camera to the right limit of the pan
range.
¾ Press the FAR key (5) to save the position.
¾ Proceed analogously for the LEFT LIMIT.
¾ Set ENABLE to ON to activate the limitation of the pan range.
¾ Select SWAP RIGHT/LEFT to swap the left and right limit.
TILT OVER ANGLE
VIEW ANGLE SETUP
TILT OVER ANGLE
SAVE AND EXIT
SELECT → LEFT/RIGHT
:
ON
The VIEW ANGLE SETUP
menu allows you to define the
tilt range of the camera.
¾ Set TILT OVER ANGLE to ON, W/O BUBBLE or WITH
BUBBLE.
POWER UP ACTION
DOME MENU
TITLE SET
FLIP
SPEED
RUNNING RANGE
TILT OVER ANGLE
POWER UP ACTION
HOME
SYSTEM INFORMATION
FACTORY
EXIT
SELECT → LEFT/RIGHT
52
:
:
:
→
ON
FAST
→
→
OFF
→
→
If you set POWER UP ACTION to ON the camera
memorizes its last position
and moves back to it after a
power failure.
Dallmeier electronic GmbH & Co.KG
HOME
HOME FUNCTION
FUNCTION
NUMBER
TIME
OPERATION
SAVE AND EXIT
SELECT → LEFT/RIGHT
:
:
:
:
PRESET
--010 SEC
OFF
The HOME FUNCTION menu
allows you to define the home
position of the camera.
The home position is the
position the camera returns to
after a certain period of
inactivity.
The home position can be a single camera position (Preset) or a
specific tour (Pattern, Autoscan, Tour).
The position or tour must be previously defined in the MOTION
menu (section 8.2.3)
¾ Set FUNCTION to PRESET, PATTERN, AUTOSCAN or TOUR.
¾ Set the NUMBER of the position or tour.
¾ Set the TIME after which the camera is to move to its home
position.
¾ Set OPERATION to ON to activate the settings.
NOTE
The shortcut 91 + F1 causes the camera to move
to the home position before the expiration of the
set time.
SYSTEM INFORMATION
SYSTEM INFORMATION
CAMERA TYPE
H/W VERSION
ROM VERSION
PROTOCOL
BAUDRATE
EXIT
SELECT → LEFT/RIGHT
:
480CP
:
V1.2
:
V1.3
:
D
: 2400BPS
The SYSTEM INFORMATION
menu contains information
about the camera.
FACTORY
FACTORY DEFAULT
ARE YOU SURE?
YES : ZOOM, NO : NEAR
Dallmeier electronic GmbH & Co.KG
(Y/N)
The FACTORY DEFAULT
menu allows you to reset the
DOME MENU settings to
default.
53
DDZ3018A-DN/DDZ3026A-DN
¾ Press the Wide/Zoom key (2) to reset the settings.
¾ Press the Near/Focus key (4) to leave the menu without resetting
the settings.
9.2.2
Camera
CAMERA MENU
→
FOCUS
→
WB
→
AE
→
LINE LOCK
BLC
:
OFF
SHARPNESS
:
9
:
OFF
D. ZOOM
→
DAY NIGHT
CAMERA DEFAULT
STABILIZER
:
OFF
SAVE AND EXIT
SELECT → LEFT/RIGHT → SUB MENU
DDZ3026A-DN only
FOCUS
FOCUS SETUP
MODE
AF SENSITIVITY
EXIT
SELECT → LEFT/RIGHT
:
:
MANUAL
HIGH
The FOCUS SETUP menu
allows you to choose between
automatic (AUTO) and MANUAL focus.
In addition, you can set the sensitivity of the focus (AF
SENSITIVITY).
WB (Wjote balance)
WB SETUP
MODE
R GAIN
B GAIN
EXIT
SELECT → LEFT/RIGHT
:
:
AUTO
208
170
The WB SETUP menu allows
you to set the white balance
and thus adapt the color
temperature to the prevailing
light conditions.
Automatic white balance
¾ Depending on the scenario, set MODE to AUTO, INDOOR,
OUTDOOR, ONE PUSH or ATW.
54
Dallmeier electronic GmbH & Co.KG
Manual white balance
¾ Set MODE to MANUAL to manually perform the white balance.
AE
AE SETUP
MODE
: FULL AUTO
SLOW SHUTTER
:
AUTO
IRIS
:
F9.6
GAIN
:
0DB
BRIGHT
:
06
:
1/60
SHUTTER
EXIT
SELECT → LEFT/RIGHT
The AE SETUP menu allows
you to adapt the camera’s
exposure parameters to the
prevailing
scenario.
Depending on the selected
mode, single parameters such
as IRIS, SHUTTER etc. can be
set additionally.
¾ Set MODE to FULL AUTO, MANUAL, IRIS PRIO, SHUTTER
PRIO or BRIGHT.
¾ Set single parameters, if applicable.
LINE LOCK
LINE LOCK SETUP
MODE
: INTERNAL
PHASE
:
004
EXIT
SELECT → LEFT/RIGHT
The LINE LOCK SETUP
menu allows you to set the
synchronization (INTERNAL /
EXTERNAL) and to adjust the
phase.
BLC (backlight compensation)
CAMERA MENU
→
FOCUS
→
WB
→
AE
→
LINE LOCK
BLC
:
ON
SHARPNESS
:
9
:
OFF
D. ZOOM
→
DAY NIGHT
CAMERA DEFAULT
STABILIZER
:
OFF
SAVE AND EXIT
SELECT → LEFT/RIGHT → SUB MENU
Dallmeier electronic GmbH & Co.KG
Set BLC to ON to prevent the
object as far as possible from
being blanked when recording
against backlight.
DDZ3026A-DN only
55
DDZ3018A-DN/DDZ3026A-DN
SHARPNESS
CAMERA MENU
→
FOCUS
→
WB
→
AE
→
LINE LOCK
BLC
:
ON
:
9
SHARPNESS
:
OFF
D. ZOOM
→
DAY NIGHT
CAMERA DEFAULT
STABILIZER
:
OFF
SAVE AND EXIT
→
SUB
MENU
→
SELECT
LEFT/RIGHT
Set the desired
sharpness.
image
DDZ3026A-DN only
D. ZOOM
CAMERA MENU
→
FOCUS
→
WB
→
AE
→
LINE LOCK
BLC
:
ON
SHARPNESS
:
9
:
OFF
D. ZOOM
→
DAY NIGHT
CAMERA DEFAULT
STABILIZER
:
OFF
SAVE AND EXIT
→
→
SUB
MENU
SELECT
LEFT/RIGHT
Set the desired zoom factor for
the digital zoom.
DDZ3026A-DN only
DAY/NIGHT
DAY NIGHT SETUP
MODE
LOCAL CONTROL
EXIT
SELECT → LEFT/RIGHT
:
:
AUTO
OFF
The DAY NIGHT SETUP
menu allows you to choose
between automatic and
manual activation of the day /
night mode.
During night mode images are
displayed and recorded in
black-and-white.
¾ If you set MODE to AUTO the camera automatically switches to
night mode at a certain point in time.
¾ If you set MODE to MANUAL and LOCAL CONTROL to ON the
camera immediately switches to night mode regardless of the
prevailing light conditions.
¾ Set MODE to MANUAL and LOCAL CONTROL to OFF to
deactivate the night mode.
56
Dallmeier electronic GmbH & Co.KG
CAMERA DEFAULT
CAMERA DEFAULT
ARE YOU SURE?
YES : ZOOM, NO : NEAR
(Y/N)
The CAMERA DEFAULT menu
allows you to reset the CAMERA
MENU settings to default.
¾ Press the Wide/Zoom key (2) to reset the settings.
¾ Press the Near/Focus key (4) to leave the menu without resetting
the settings.
STABILIZER
CAMERA MENU
→
FOCUS
→
WB
→
AE
→
LINE LOCK
BLC
:
ON
SHARPNESS
:
9
:
OFF
D. ZOOM
→
DAY NIGHT
CAMERA DEFAULT
STABILIZER
:
OFF
SAVE AND EXIT
→
→
SUB
MENU
SELECT
LEFT/RIGHT
9.2.3
Set STABILIZER to ON to
activate the image stabilization.
DDZ3026A-DN only
MOTION
MOTION MENU
PRESET
TOUR
SCAN
PATTERN
ALARM
EXIT
SELECT → LEFT/RIGHT
→
→
→
→
→
→
PRESET
PRESET MENU
PRESET NO:001
: UNDEFINE
LABEL
:
PRESET
POSITION
:
NONE
FOCUS
:
MANUAL
IRIS
:
AUTO
:
OFF
BLC
CLEAR
SAVE AND EXIT
SELECT → LEFT/RIGHT/TELE/WIDE
Dallmeier electronic GmbH & Co.KG
The PRESET menu allows
you to save 248 camera
positions (presets).
Presets can be called by means
of the PTZ controller or be used
as home position, alarm
position or for defining a tour.
57
DDZ3018A-DN/DDZ3026A-DN
Saving a preset
¾ Select a preset (number) in the first line.
¾ Select LABEL to assign a name to the preset.
Turn the joystick to enter the characters.
Move the joystick to the right to activate the next position.
¾ Select POSITION and press the TELE key (3).
Use the joystick to move the camera to the desired position.
Press the FAR key (5) to save the position.
¾ Set FOCUS and IRIS to AUTO or MANUAL.
¾ Set BLC to ON or OFF.
Deleting a preset
CLEAR PRESET
ARE YOU SURE?
YES : ZOOM, NO : NEAR
(Y/N)
¾ Select CLEAR and then
Wide/Zoom (2) to delete
the preset.
¾ Press the Near/Focus key (4) to leave the menu without deleting
the preset.
Calling a preset
The shortcut No. of preset + F1 allows you to directly call a preset.
TOUR
The TOUR menu allows you
to define and save 8 tours.
TOUR MENU
TOUR 01
:
LABEL
:
TOUR EDIT
CLEAR
SAVE AND EXIT
SELECT → LEFT/RIGHT
UNDEFINE
TOUR 01
Tours can be started by means
of the PTZ controller or be
used as home position.
The single positions of a tour can be previously defined presets or
other tours or ranges (Pattern, Scan, Tour).
58
Dallmeier electronic GmbH & Co.KG
Defining and saving a tour
¾ Select a tour in the first line.
¾ Select LABEL to assign a name to the tour.
Turn the joystick to enter the characters.
Move the joystick to the right to activate the next position.
¾ Select Tour EDIT.
NO
FUNC
NUMBER S DWEL
01
PRST
01
F
3
02
PRST
02
F
3
03
------04
------SET (FAR) DEL (NEAR)
SELECT → LEFT/RIGHT/TELE/WIDE
¾ Define the first position of the tour in the FUNC and NUMBER
columns.
¾ Set the camera’s motion speed in the S column.
¾ Set the dwell time for the first position in the DWEL column.
¾ Proceed analogously for all other positions of the tour.
¾ Press the FAR key (5) after defining all positions.
Deleting a tour
¾ Select CLEAR and then Wide/Zoom (2) to delete the tour.
Press the Near/Focus key (4) to leave the menu without deleting
the tour.
CLEAR TOUR
ARE YOU SURE?
YES : ZOOM, NO : NEAR
(Y/N)
Starting the tour
The shortcut No. of tour + F3 allows you to start a tour.
NOTE
Use the joystick to send a command to the camera
(pan, tilt, zoom, focus) to stop a tour.
Dallmeier electronic GmbH & Co.KG
59
DDZ3018A-DN/DDZ3026A-DN
SCAN
The SCAN menu allows you
to define and save 16 individual pan ranges.
SCAN MENU
SCAN NO:001
:
UNDEFINE
LABEL
: AUTOSCAN 01
START
:
NONE
END
:
NONE
SPEED
:
3
:
CCW
DIR.
SWAP
:
OFF
CLEAR
SAVE AND EXIT
SELECT → LEFT/RIGHT/TELE/WIDE
Pan ranges can be scanned
by means of the PTZ
controller or be used as home
position or single position for
a tour.
Defining and saving a pan range
¾ Select a pan range in the first line.
¾ Select LABEL to assign a name to the pan range.
Turn the joystick to enter the characters.
Move the joystick to the right to activate the next position.
¾ Select START and press the TELE key (3).
Use the joystick to move the camera to the first position of the
pan range.
Press the FAR key (5) to save the position.
¾ Proceed analogously for the second position (END).
¾ Set the camera’s motion speed in the SPEED column.
¾ Set the direction (DIR.) with which the camera is to scan the
pan range (CW = clockwise, CCW = counter-clockwise).
¾ Set SWAP to ON to swap the two position coordinates.
Deleting the pan range
CLEAR SCAN
ARE YOU SURE?
YES : ZOOM, NO : NEAR
(Y/N)
¾ Select CLEAR and then
Wide/Zoom (2) to delete
the pan range.
¾ Press the Near/Focus key (4) to leave the menu without deleting
the pan range.
Scanning a pan range
The shortcut No. of pan range + F4 causes the camera to scan a
pan range.
60
Dallmeier electronic GmbH & Co.KG
NOTE
Use the joystick to send a command to the camera
(pan, tilt, zoom, focus) to stop a pan range from
being scanned.
PATTERN
PATTERN MENU
PATTERN NO:001
:
UNDEFINE
LABEL
: PATTERN 01
RECORD SAVE
:
000 SEC
→
PLAY
:
CLEAR
SAVE AND EXIT
SELECT → LEFT/RIGHT
The PATTERN menu allows
you to define and save 4 individual tours (patterns).
Unlike a tour defined in the TOUR menu, a pattern is a recorded
sequential series of pan, tilt, zoom and focus movements of the
camera.
That way a smoother and more thorough type of tour can be
realized.
These individual patterns can be run by means of the PTZ controller
or be used as home position.
Defining and saving a pattern
¾ Select a pattern in the first line.
¾ Select LABEL to assign a name to the pattern.
Turn the joystick to enter the characters.
Move the joystick to the right to activate the next position.
¾ Select RECORD SAVE and move the joystick to the right.
¾ Use the control, zoom and focus buttons to define the pattern.
¾ Press the FAR key (5) to save the pattern.
¾ Select PLAY to play back the saved pattern for checking
purposes.
Deleting a pattern
CLEAR PATTERN
ARE YOU SURE?
YES : ZOOM, NO : NEAR
Dallmeier electronic GmbH & Co.KG
(Y/N)
¾ Select CLEAR and then
Wide/Zoom (2) to delete
the pattern.
61
DDZ3018A-DN/DDZ3026A-DN
¾ Press the Near/Focus key (4) to leave the menu without deleting
the pattern.
Running a pattern
The shortcut No. of pattern + F5 allows you to run a pattern.
NOTE
Use the joystick to send a command to the camera
(pan, tilt, zoom, focus) to stop a pattern from being
run.
ALARM
ALARM MENU
ALARM NO:001
:
MOTION
:
PRIORITY
:
ALARM IN
:
ALARM OUT
:
:
HOLD
LATCH
:
SAVE AND EXIT
SELECT → LEFT/RIGHT
UNDEFINE
OFF
3
OFF
OFF
001 SEC
OFF
The ALARM menu allows you
to determine previously
defined presets the camera
automatically moves to if an
alarm is triggered (relay is
switched).
¾ Select an alarm in the first line.
¾ Select next to MOTION the preset that is to be called if an alarm
is triggered.
¾ Assign a PRIORITY to the preset.
¾ Select the corresponding relays for ALAMR IN and ALARM OUT.
¾ Select the time for HOLD to elapse after the end of an alarm
until the camera can be controlled again.
¾ If you set LATCH to ON the alarm (preset) number will be
permanently displayed in the video image.
62
Dallmeier electronic GmbH & Co.KG
9.2.4
DISPLAY
DISPLAY MENU
→
→
→
→
→
LANGUAGE
PRIVACY ZONE
NORTH DIRECTION
AREA
DISPLAY ON/OFF
EXIT
SELECT → LEFT/RIGHT
LANGUAGE
LANGUAGE SETUP
:
LANGUAGE
SAVE AND EXIT
SELECT → LEFT/RIGHT
ENGLISH
There are currently no settings
to modify in the LANGUAGE
SETUP menu.
The default language is
English.
PRIVACY ZONE
PRIVACY ZONE SETUP
NO.
TITLE
01
NONE
02
NONE
03
NONE
04
NONE
05
NONE
06
NONE
07
NONE
08
NONE
SAVE AND EXIT
SELECT → LEFT/RIGHT
METHOD
MASK
MASK
MASK
MASK
MASK
MASK
MASK
MASK
The PRIVACY ZONE SETUP
menu allows you to mask
certain image areas.
¾ Select a number and press the TELE key (3).
¾ Use the joystick to move the camera to the image area you
want to mark.
¾ Press the FAR key (5) to save the image area.
¾ Move the joystick to the right to assign a name to the privacy
zone.
Turn the joystick to enter the characters.
Move the joystick to the right to activate the next position.
¾ Select the desired METHOD to mark the defined image area.
¾ Proceed analogously for further privacy zones.
Dallmeier electronic GmbH & Co.KG
63
DDZ3018A-DN/DDZ3026A-DN
NORTH DIRECTION
NORTH DIRECTION
:
POSITION
SAVE AND EXIT
SELECT → LEFT/RIGHT
000.0
The NORTH DIRECTION
menu allows you to direct the
camera towards north and to
save this position. The
cardinal points will then be
displayed in the video image.
¾ Press the TELE key (3).
¾ Move the camera towards north using the joystick.
¾ Press the FAR key (5) to save the position.
NOTE
Open the DISPLAY ON/OFF menu and activate
the display of the cardinal points (NORTH
DIRECTION : ON).
AREA
AREA TITLE
AREA NO : 001
:
LABEL
:
START
:
STOP
:
CLEAR
SAVE AND EXIT
SELECT → LEFT/RIGHT
UNDEFINE
-----
The AREA TITLE menu
allows you to assign a name
to the area between two
camera positions. This name
is displayed in the video image
as long as the camera moves
between the two defined
positions.
¾ Select an area in the first line.
¾ Select LABEL to assign a name to the area.
Turn the joystick to enter the characters.
Move the joystick to the right to activate the next position.
¾ Select START and move the joystick to the right.
¾ Use the joystick to move the camera to the first position of the
area.
¾ Press the FAR key (5) to save the position.
¾ Proceed analogously for the second position (STOP).
¾ Select CLEAR and then Wide/Zoom (2) to delete the area.
64
Dallmeier electronic GmbH & Co.KG
CLEAR AREA
ARE YOU SURE?
YES : ZOOM, NO : NEAR
(Y/N)
¾ Press the Near/Focus key
(4) to leave the menu
without deleting the area.
DISPLAY ON/OFF
DISPLAY ON/OFF MENU
TITLE
PRESET
TOUR
AREA
ALARM
SCAN
PATTERN
POSITION
NORTH DIRECTION
SAVE AND EXIT
SELECT → LEFT/RIGHT
:
:
:
:
:
:
:
:
:
ON
ON
ON
ON
ON
ON
ON
ON
ON
The DISPLAY ON/OFF menu
allows you to determine the
information being displayed in
the video image.
¾ Select the desired item and
choose between ON and
OFF.
CLEAR DATA
CLEAR DATA
PRESET
TOUR
AREA
ALARM
SCAN
PATTERN
EXIT
SELECT → LEFT/RIGHT
The CLEAR DATA menu
allows you to reset single
settings to default.
¾ Select the desired menu item and move the joystick to the right.
¾ Press the Wide/Zoom key (2) to reset the settings.
¾ Press the Near/Focus key (4) to leave the menu without resetting
the settings.
9.2.5
Shortcuts
Function
Shortcut
Main menu
95 + F1
Exit
96 + F1
Tour menu
70 + F1
Scan menu
60 + F1
Pattern menu
80 + F1
Dallmeier electronic GmbH & Co.KG
65
DDZ3018A-DN/DDZ3026A-DN
66
Dallmeier electronic GmbH & Co.KG
A
A1
Appendix
Menu structure
DOME MENU
TITLE SET
FLIP
SPEED
PLANNING RANGE
TILT OVER RANGE
POVER OF ACTION
HOME
SYSTEM INFORMATION
FACTORY
→
: ON
: FAST
→
→
: ON
→
→
EXIT
SELECT → LEFT/RIGHT → SUB MENU
MAIN MENU
DOME
CAMERA
MOTION
DISPLAY
CLEAR DATA
EXIT
CAMERA MENU
→
→
→
→
→
SELECT → LEFT/RIGHT → SUB MENU
DDZ3026A-DN only
FOCUS
WB
AE
LINE LOCK
BLC
SHARPNESS
D. ZOOM
DAY/NIGHT
CAMERA DEFAULT
STABILIZER
→
→
→
→
: OFF
:
9
: OFF
→
: OFF
SAVE AND EXIT
SELECT → LEFT/RIGHT → SUB MENU
MOTION MENU
PRESET
TOUR
SCAN
PATTERN
ALARM
EXIT
SELECT → LEFT/RIGHT
Dallmeier electronic GmbH & Co.KG
→
→
→
→
→
67
DDZ3018A-DN/DDZ3026A-DN
DISPLAY MENU
MAIN MENU
DOME
CAMERA
MOTION
DISPLAY
CLEAR DATA
EXIT
→
→
→
→
→
SELECT → LEFT/RIGHT → SUB MENU
68
LANGUAGE
PRIVACY ZONE
NORTH DIRECTION
AREA
DISPLAY ON/OFF
EXIT
SELECT → LEFT/RIGHT
→
→
→
→
→
CLEAR DATA
PRESET
TOUR
AREA
ALARM
SCAN
PATTERN
EXIT
SELECT → LEFT/RIGHT
→
→
→
→
Dallmeier electronic GmbH & Co.KG
A2
Technical Data
Camera
Lens
DDZ3018A-DN: 18x (4,1 – 73,8 mm), F1.4 to F3.0
DDZ3026A-DN: 26x (3,5 – 91,0 mm), F1.6 to F3.7
Sensor
1/4" CCD sensor
Effective Pixels
752 x 582 PAL / 768 x 494 NTCS
Focus
automatic with manual override
Iris
automatic with manual override
Video Output
CVBS, 75 Ohm
Synchronization
Line-lock with vertical phase adjustment (0 – 255)
or internal crystal
Digital Zoom
DDZ3018A-DN: 12x
DDZ3026A-DN: 10x
Horizontal Resolution
480 TVL
Sensitivity
DDZ3018A-DN: 0,7 lux color,
0,01 lux b/w in night-mode
DDZ3026A-DN: 1,0 lux color,
0,1 lux b/w in night-mode
SNR
DDZ3018A-DN: > 50 dB
DDZ3026A-DN: > 48 dB
White Balance
ATW, AWC, Manual
Mechanical Data
Pan/Tilt
360° continuous pan
0.1° to 90° tilt from horizontal plane
Preset Speed
Pan: 390°/sec., ± 0.1° accuracy
Tilt: 150°/sec., ± 0.05° accuracy
Functions
Presets
248
Tours
8
Patterns
4 (240 seconds overall)
Autoscan
8
Horizontal Flip
Digital / Auto / Off
Privacy Zones
8 (Mask / Video off)
Addressing
up to 999 addresses settable (via rotary switches)
Camera Control
RS-485 / RS-422
automatic protocol detection
2400, 4800, 9600, 19200 bps
Alarm IN
8 alarm inputs (NO / NC, priority)
Alarm OUT
2 relay outputs (Hold, Latch)
Display
camera name, preset name, tour name, pattern name,
autoscan name, area name, north position
Dallmeier electronic GmbH & Co.KG
69
DDZ3018A-DN/DDZ3026A-DN
Connections
Power (camera)
21 – 28 V AC, 50/60 Hz - 15 W max.
Power (heater)
21 – 28 V AC, 50/60 Hz - 15 W max.
RS-485
+ / - optional control data
Video
BNC
Alarm Inputs (8)
programmable for "Normally Open“ or "Normally Close“
Relay Outputs
2 relay outputs
Electrical Data
Power Supply
24 V AC, 50/60 Hz
Power Consumption
18.0 W (1.0 A max.)
Heater: 30.0 W
Fan: 3.4 W
Environmental Conditions
Ingress Protection
IP67 (weather proof housing)
Operating Temperature
0 ° to 50 °C indoors (32 ° to 122 °F)
-40 ° to 50 ° C outdoors (-40 ° to 122 °F)
Storage temperature
-20 ° to 60 °C (4 ° to 140 °F)
Rel. Humidity
0% to 90% non-condensing
Weight and Dimensions
Weight
approx. 1.5 kg
Dimensions
125 mm diameter, 176 mm height
Certifications
70
CE, FCC CLASS A
Dallmeier electronic GmbH & Co.KG
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising