Manosys Receiver: EMP2•EMP3
Manosys Receiver: EMP2•EMP3
Bellex International Corporation
Manosys Receiver: EMP2•EMP3
This unit is used in combination with the Manosys Pressure Transmitter.
Display, calculation, alarm signal output and signal output can be done only with this receiver.
This Receiver is standard-equipped with a 2-line DC power source for transmitter, and square root
calculation function (airflow meter only).
With Alarm Output
Without Alarm Output
Product Code Naming
RangeCode
EMP
2
D
2
1
1
D
300
(Example)
Range
Maximum Pressuer
D
Unit
E
Pressure
3
L
M
Pa
kPa
m /min
3
Air Flow
m /h
3
N
m /min(nor)
O
m /h(nor)
3
0
None
1
4-20mA DC
1
4-20mA DC
Alarm Output
0
None (only with EMP3)
Display
2
2 Circuites (only with EMP2)
D
Digital Display
2
Panel Type #2
3
Panel Type #3
Output Siginal
Input Signal
Outer Case
Manosys Receiver: EMP2•EMP3
Specifications
Model
Bellex International Corporation
Display
EMP2
Digital 3 1/2 digit
EMP3
Input Signal
4~20mA DC (Input resistance 250Ω) Max. value may vary in case of airflow measurement.
2-line type DC power supply for use with pressure transmitter, internal 24V DC
Output Signal
None or 4~20mA DC (load resistance 500Ω or less)
In case of airflow measurement, input signal is the extracted square root of the output signal.
Output Signal Accuracy
± 1%F.S. (at 20°C), For airflow measurement: 15-100%F.S extracted output value only.
Power Supply
100V AC ± 10% 50/60 Hz, EMP2 Appx. 7VA, EMP3 Appx. 6VA
Alarm
2 circuits
(one each for upper and lower limits)
ABS resin (ivory)
0°C~50°C (no icing)
90%RH or less (no condensation)
Terminal to ground: over 20MΩ (500V DC megger)
Terminal to ground: 1500V AC 50/60Hz 1 min
Installation fittings (2)
Approx. 650g
(Relay Contact Output)
Outer Casing
Operating Temp.
Operating Humidity
Insulation Resistance
Voltage Resistance
Accessories
Weight
None
Approx. 500g
Manosys Receiver: EMP2•EMP3
Pressure Range
Code
D10
D20
D30
D50
D100
D200
D300
D500
D1000
E2
E3
E5
E10
E20
E30
E50
D ± 10
D ± 20
D ± 30
D ± 50
D ± 100
D ± 200
D ± 300
D ± 500
D ± 1000
E±2
E±3
E±5
Airflow Range
Code
None
Pressure
Range
0~10 Pa
0~20 Pa
0~30 Pa
0~50 Pa
0~100 Pa
0~200 Pa
0~300 Pa
0~500 Pa
0~1 kPa
0~2 kPa
0~3 kPa
0~5 kPa
0~10 kPa
0~20 kPa
0~30 kPa
0~50 kPa
± 10Pa
± 20Pa
± 30Pa
± 50Pa
± 100Pa
± 200Pa
± 300Pa
± 500Pa
± 1000Pa
± 2 kPa
± 3 kPa
± 5 kPa
Bellex International Corporation
Accuracy
at 20°C
Temp. Drift
(0~40°C)
Alarm
Form of output:
2 X SPDT
(one circuit at upper and lower limits)
±1%F.S.
± 1 digit
For airflow
±0.05%F.S/°C
measurement:
Contact Capacity:
MAX. 1.5A 120V AC
1.5A 30V DC
MIN. 0.1A 5V DC
Range of Settings:
Upper Limit: 15-100%F.S.
Lower Limit: 0-85%F.S.
15-100% F.S
On-Off Dead band:
Within 2% F.S.
Airflow Range
(Note 1)
0~A B C
3
3
3
3
Note 1: A: Value (rounded off), B: Multiplying power (x10, x100, x1000, x10000), C: Unit (m /h, m /min, m /h(nor), m /min(nor))
•
Negative displays (such as 0~ -100Pa) are also available.
For more information, please contact:
Bellex International Corporation
200 Bellevue PKWY, Suite 180
Wilmington, DE 19809, USA
Tel: 302-791-5180, Fax: 302-791-5190,
www.bellexinternational.com