Technical specification

Housing Polycarbonate

Dimensions (w x h x d) 193 x 160 x 73 mm

Weight 1.2 kg

Protection class IP 66

According to EN 60529

Ambient temperature -25 °C to +70 °C

Communication software Telves communication software

for Windows

Measuring temperature range -25 °C to +60 °C

Measuring pressure ranges (absolute)

MID certified Non MID

- standard range: 0.8 - 5.2 bar 0.8 - 5.2 bar

2 - 10 bar 0.8 - 10 bar

4 - 20 bar

7 - 35 bar

14 - 70 bar

- enhanced range: 0.8- 10 bar

0.8 - 20 bar

0.8 - 35 bar

0.8 - 70 bar

4 - 70 bar

Power supply Lithium battery

Operating lifetime >6 years in defined conditions with option of intrinsic safe external power supply JBZ-02

4.7 - 10 V at hazardous area

4.7 - 15 V at non-hazardous area

Type of battery SAFT standard lithium battery

Control panel 6-key keypad

Display

(D size 3.6V/17Ah)

Graphical LCD display with backlighting (also in battery mode),

128 x 64 pixels

Approvals - Approved according to the

European metrology standard EN

12405-01 and 2004/22/EC (MID)

- ATEX approval for installation

into Hazardous area

FTZU 08 ATEX 0324X

- Classification (according to

EN 60 079-0, EN 60 079-11)

II 2G Ex ia IIC T4/T3

- CE marking: according to

Accuracy .5

from measured value (MID)

<0.15 % typically from measured val.

89/336/CE (EMC) and

94/9/CE (ATEX)

Delivery

Communication interface - standard delivery: - Manual

- RS-232 / RS-485 serial interface

- Optical interface IEC-1107

- Software for Windows 98, ME,

2000, XP or Vista

- optional accessories: - Thermowell

Communication speed

- Mounting kit

- Intrinsically safe power supply

- RS232/RS485: 9.6 - 57.6 kbit/sec

- Optical interface: 9.6 - 38.4 kbit/sec

JBZ-02

- Three-way tap, type DN 3 PN 100

Data communication - GSM, GPRS

- PSTN or radio modem

- communication module

DATCOM-K3, K4

- GPRS communicator DATCOM-

AMR2, AMR3

- Pressure transmitter EDT-23

- Temperature transmitter EDT-34

Manufacturer: ELGAS, s. r. o., Ohrazenice 211, 533 53 Pardubice, Czech republic tel.: +420/ 466 414 500, 466 414 511 fax: +420/ 466 411 190

E-mail: [email protected], http://www.elgas.cz

Certificate according to EN ISO 9001:2001

Revision 1

®

BATTERY POWERED

GAS VOLUME CONVERSION DEVICE

With option of external power supply

miniElcor

Complex solution for custody transfer measuring

And telemetric data collecting

High performance valuable product

Basic telemetric functions

Battery lifetime more than 6 years

Typical error under reference conditions

< 0.15 % of measured value

Graphical LCD display with backlighting

h

Possibility to connect 2nd pressure or temperature sensor

„Basic parameters setting via keypad

Large capacity of different type of archives

Designed for hazardous area ZONE 1 and ZONE 2

EC certificate FTZU 08 ATEX 0324X

Microsoft Windows compatible software

Remote reading option

M 09 1383

1026

Accuracy of measurement

- Maximum error:  0.5 % from measured value

- Typical error: < 0.15 % from measured value

Basic description

MiniElcor is designed for converting of gas volume in operating conditions to gas volume in standard conditions according to state equation. For that purpose, it reads pulses from gas meter, measures gas temperature and pressure. The gas volume corrector is of the PTZ, PT, TZ or T type. The device supports those algorithms for calculation of compressibility factor according to standards AGA 8-92DC, AGA NX-

19 mod, AGA 8-G1, AGA 8-G2, SGERG-88 or fixed.

Mechanical concept of the device is selected to operate as a single channel. Device configuration also enables measuring and monitoring other quantities.

Power supply

The device operates from inbuilt lithium battery for 6 years in defined operating conditions. It is possible to use pulse outputs during battery power supply. In case of request for operation mode with increased consumption, external power supply with intrinsically safe sources can be used (JBZ-02,

DATCOM-K3/K4).

Communication

Communication with superior system

For connection with superior system can be used RS-232 or

RS-485 or infrared optical port.

Communication can be realized through the PSTN modem,

GSM or GPRS modem or with radiomodem. TCP/IP protocol is supported. The device is equipped with communication protocols ELGAS version 2, MODBUS . Another protocols can be used on request.

Communication with modem GSM, GPRS

For the purposes of diagnostics during modem installation, there is realized possibility of representing information from a modem about presence and connection to GSM or GPRS network and information about strength of a signal measured by modem.

Communication and telemetry

Device is equipped with functions which are standard for telemetric systems. It enables monitoring excesses of set limits, sending alarms to control centre, operation of modem and others.

Example of application

MiniElcor is constructed on the latest microprocessor technology which enables measuring of pressure and temperature using analog transducers. The device provides large capacity of archives and enables flexibly to change period of data recording.

As a standard function the device offers generator of output digital pulses which respond to primary and standard volume and alarm signal. Protection of data is secured either by hardware switch or by using programmable passwords.

MiniElcor is designed for complex solution based on flexible modular system. MiniElcor is battery power supplied with option of external power supply. All required actual and calculated values are presented on back lighted graphical LCD display with using of 6-buttons keypad. It is also possible to make basic parametrization through keypad. Communication with superior system can be realized trough serial interface RS-

232/RS-485 or infra-red head.

Communication software

®

Temperature sensor

- Pt-1000 probe

- Length 120 mm, Ø 5.7 mm

- T c

- Accuracy:  0.1% from measured value

- Possibility to add another temperature transducer (EDT-34)

Pressure transducer

- Internal or external pressure transducer

- Possibility to add another pressure transducer (EDT-23)

- cable lenght up to 5 m

- S ilicon piezorezistive sensor

- Connection - thread M12 x 1,5

- Accuracy:  0.25 % from measured value

Digital inputs

4 digital inputs (configurable as):

- LF input

- HF input (NAMUR)

- binary input or tamper LF input

- binary input NAMUR

- encoder

- LF input pulse frequency: max. 10 Hz

- LF pulses: reed contact or Wiegand

- HF input pulse frequency: max. 5 kHz - with external

power supply

- HF pulses: NAMUR (DIN 19234) - with external

Power supply

Digital outputs

4 digital outputs (configurable as)

- Pulse output (primary volume, standard volume,

odorization control, etc.), programmable pulse 0.1 sec to

25 sec

- Binary output (alarm etc.)

- Analog output - realized trough CL-1 module (4 - 20 mA)

Compressibility formulas

- AGA-8 92DC

- AGA NX-19mod

- SGERG-88

- AGA 8-G1

- AGA 8-G2

- Fixed

Data protection

Data are protected by:

- Using password

- Switch, which is placed inside of the device

Communication interface

- RS-232 / RS-485 serial interface

- Optical interface (IEC-1107)

Display and keypad

- clear graphical LCD display with backlighting

(Backlighting also in battery mode), operated

by 6-button keypad

- Display of measured current values and pre-set

Parameters

- Possibility to set basic parameters trough keypad

Error conditions

The device indicates and stores different error´s

conditions which can be set as alarm status:

- Disturbation of gas meter

- Full audit log

- Low capacity of battery warning

(3 months in advance)

- Exceeding of measured range of pressure and

temperature

- Exceeding of upper limit of flow rate

Memory

- Memory type: FLASH, 1MB

- Data archive: 14300 records (flexible - according to

configured parameters), programmable period: 1 - 60 min

- Daily archive: 400 records

- Status archive: over 500 records, contains formation and

Extinction of errors, date and time.

- Monthly archive: 25 records

- Audit log: over 500 records, contains the changes of

Parameters.

Example of application