Compact control module with ambient light sensor and motion sensor
Product description
• Compact dimensions for luminaire installation
• For up to 10 DSI or DALI devices (max. 5 per output channel)
• 2 DALI/DSI output channels with adjustable negative offset from
channel 2 to channel 1
• Ambient light sensor with motion detector
• Max. installation height 5 m
• Switch input for on/off switching and dimming
• Can be remote controlled
• Individual adjustment of the parameters with
basicDIM ILD Programmer or DSI-SMART Programmer
basicDIM ILD 5DPI 14F
• 5-year guarantee
È
Wiring diagrams and installation examples, page 7
basicDIM ILD 5DPI 14F Black
basicDIM ILD 5DPI 14F Black 1.8m
Data sheet 04/17-CO078-13
Subject to change without notice.
www.tridonic.com
1
luxCONTROL lighting control system
basicDIM
basicDIM ILD 5DPI 14f
Compact control module with ambient light sensor and motion sensor
50 / 60 Hz
Power
2W
Stand-by power
0.5 W
Momentary-action switch input for dimming
single
Digital control line DSI/DALI
2
Control output (devices)
10
Max. output cable length at 1.5 mm²
100 m
Operating temperature
0 ... +60 °C
Storage temperature
-25 ... +70 °C
Type of protection
IP20
Max. casing temperature tc
75 °C
30
120
110
30
220 – 240 V
Mains frequency
16,4
Rated supply voltage
21
Technical data
1,9
3
12,8
2
44,4
Ø13,9
Ordering data
Type
Article number
Mounting
Packaging carton
basicDIM ILD 5DPI 14f
28001203
Luminaire installation
10 pc(s).
basicDIM ILD 5DPI 14f Black
28001529
Luminaire installation
10 pc(s).
basicDIM ILD 5DPI 14f Black 1.8m
28001528
Luminaire installation
10 pc(s).
Specific technical data
Type
Detection
Light detection angle
asymmetric
Light measurement at
the sensor head1
Illuminance (factory default)2 Motion detection angle symmetric Max. cable length sensor
basicDIM ILD 5DPI 14f
60°
10 – 500 lx
150 lx
78°
0.8 m
basicDIM ILD 5DPI 14f Black
60°
10 – 500 lx
150 lx
78°
0.8 m
basicDIM ILD 5DPI 14f Black 1.8m
60°
10 – 500 lx
150 lx
78°
1.8 m
1
The measured value at the sensor head corresponds to approx. 15 to 2,000 lux on the surface measured.
2
The illuminance is set for a room defined by Tridonic. Depending on the actual room (reflectance) the measured illuminance may deviate from this value.
The illuminance should therefore be checked in the installation and adjusted if necessary.
Data sheet 04/17-CO078-13
Subject to change without notice.
www.tridonic.com
2
ACCESSORIES
luxCONTROL lighting control system
basicDIM
REMOTECONTROL IR6
Product description
• Optional infra-red remote control
• Switching on and off (On/Off button)
• Dimming (Up/Down button)
• Activation of automatic lighting control
• Setting the threshold control point (Set button)
ACCESSORIES
Ordering data
Type
Article number Dimensions L x W x H Packaging carton
REMOTECONTROL IR6
28000647
86.5 x 40.5 x 7.2 mm
500 pc(s).
basicDIM ILD Programmer
Product description
• Optional infra-red programming unit for basicDIM ILD
• Setting of predefined discrete parameter values
• Programmable functions such as light level, time delay,
P.I.R., bright-out, power up
Ordering data
Type
Article number
Packaging carton
Weight per pc.
basicDIM ILD Programmer
28000257
210 pc(s).
0.3 kg
Data sheet 04/17-CO078-13
Subject to change without notice.
www.tridonic.com
3
ACCESSORIES
luxCONTROL lighting control system
basicDIM
DSI SMART Programmer
Product description
44
• Optional infra-red programming unit for DSI-SMART PTM
100
2,5
or basicDIM ILD1
• Settings can be read and modified
180
• Programmable functions such as light level, time delay,
P.I.R., bright-out, power up
Ordering data
Article number
Packaging carton
Weight per pc.
DSI-SMART Programmer
28000843
1 pc(s).
0.35 kg
SORIES
At version 2.30 for basicDIM ILD.
ACCES-
1
Type
5DPI 14f Mounting Kit
Product description
• Mounting frame for attaching all 5DP 14f sensor directly to
the luminaire housing
• Shutter for preventing movement detection in one direction
Ordering data
Type
Article number Packaging carton Weight per pc.
5DPI 14f mounting kit
28001558
100 pc(s).
0.004 kg
5DPI 14f mounting kit black
28001575
100 pc(s).
0.004 kg
Data sheet 04/17-CO078-13
Subject to change without notice.
www.tridonic.com
4
luxCONTROL lighting control system
basicDIM
Standards
EN 55015
EN 61000-3-2
EN 61347-1
EN 61347-2-11
EN 61547
EN 62386-101
basicDIM ILD
The basic DIM ILD provides the basis for an easy-to-use and cost-effective
lighting system with motion detection.
When the sensor detects movement it triggers a individual adjustable motion
detection profile in the control unit.
As the amount of natural ambient light changes the illuminance from the
artificial lighting system is adjusted.
The connected luminaires can be switched on and off via momentary-action
switch or remote control possible.
IR is always active.
Glow-wire test
according to EN 61347-1 passed.
DALI standard
The basicDIM ILD is designed to control control
gear with DALI standard IEC 60929 (DALI V0)
and IEC 62386 (DALI V1).
Installation
• Don‘t use the basicDIM ILD without the sensor.
• DSI/DALI is not SELV. The installation instructions for mains
voltage therefore apply.
• The maximum cable length between the external switch and
basicDIM ILD is 100 m.
• The cable between the luminaire installation sensor and the base
module must not be extended.
• A synchronous operation of DALI and DSI ballasts at the same
control gear is not possible.
• The maximum cable length of the DSI / DALI control signal
(for a cable cross-section of 1,5 m2) must not be exceeded.
• Any number of push to make switches may be connected in
parallel to the inputs.
• Do not connect standard switches to the input.
• Please ensure that the detection range of the sensor lies in the
lighting area of the controlled luminaires.
• Please ensure that the detection ranges of the sensors do not
overlap. This may have influence to the lighting control.
•
•
•
•
Heaters, fans, printers and copiers located in the detection zone may
cause incorrect presence detection.
To avoid false readings, the sensor should be installed so there is
no direct light from the lamp in the detection zone.
To avoid false measurements caused by the light from other
luminaires we recommend that the sensor should be located centrally
in the luminaire.
Sensor wires must be routed separately from the lamp wires and
mains cables otherwise the lighting control system may malfunction.
If separate routing is not possible (for reasons of space) shielded
lamp wires and mains cables must be used.
Mounting variants luminair housing:
Size of the sheet: 0.8 – 1.8 mm
Size of the sheet: 0.6 – 0.8 mm
1,5 – 2,5
ø14,1+0,2
0
2,2 +0,2
0
19,1
20 +0,1
-0,1
4 +0,2
0
ø1,8 +0,1
0
0
3,2 -0,15
Size of the sheet: 0.8 – 3.0 mm
3,3 – 5,5
14,1+0,2
0
41,1+0,2
0
R1,9 0-0,2
Data sheet 04/17-CO078-13
Subject to change without notice.
www.tridonic.com
5
luxCONTROL lighting control system
basicDIM
Mounting in luminaire housing with Mounting Kit:
Size of the sheet: 0.8 – 2.0 mm
Shutter support ring has to be snapped
into the shutter support
,9
R0
,2
ø21
Thickness metal sheet 0.8 – 2.0 mm
1,8±0,05
,1
+0 ,0
–0
0.8
Dimension drawing for needed
mounting opening
10,65±0,05
Option shutter:
has to be snapped
into the shutter support ring
Mounting Kit mounting
Mounting Kit Shutter
Area which is masked by the shutter.
120°
Data sheet 04/17-CO078-13
Subject to change without notice.
www.tridonic.com
6
luxCONTROL lighting control system
basicDIM
Switch
basicDIM ILD has an input terminal for an external switch. Any number of switches can be connected in parallel to the terminal.
Short press (> 50–600 ms):
ON/OFF
Long press (> 600 ms):
Dim up/down
A change in the light value deactivates lighting regulation only temporarily. As soon as the luminaire has been
automatically switched on again (motion detection) or manually switched off and on again, regulation is
activated again.
2 x short press:
The overwritten setpoint light value is stored (luminaire acknowledges by flashing twice)
Function is lockable via the DSI programmer
DSI/DALI interface
The interface selection DSI or DALI is made by the DSI SMART Programmer.
Wiring diagram basicDIM ILD
Cable types and cable cross-sections
Solid wire with a cable cross-section of 0.5 mm² to 1.5 mm².
wire preparation:
0.5 – 1.5 mm²
L
N
8 – 9 mm
2
3
4
PCA
6 DA
7 DA
L
N
T
basicDIM ILD
Sensor
CH1
D1
D2
CH2
D1
D2
2
3
4
PCA
6 DA
7 DA
basicDIM ILD Sensor
Enhancement of controllable light point
By using a combination of DALI Repeater and DALI Power Supply it is possible
to enhance the sum of controllable light points. The schematic visualizes the
wiring.
L
N
Max. 120
Max. 2
2
3
4
N ~ L
LCA
PS2
6 DA
7 DA
L
N
T
Sensor
basicDIM ILD
CH1
D1
D2
CH2
D1
D2
DA
DA
IN
DA
DALI Repeater
DA
2
3
4
LCA
6 DA
7 DA
DA
OUT
DA
basicDIM ILD Sensor
Use only in combination with DALI Repeater (86458401) and one of the following DALI Power Supplies:
DALI PS1 (24034323), 200 mA, max. 100 additional devices
DALI PS2 (28000876), 240 mA, max. 120 additional devices
Wire length for 1.5 mm2 cables:
• from basicDIM to DALI Repeater max. 100 m
• after DALI Repeater max. 300 m
This combination can be used on CH1 and CH2.
Data sheet 04/17-CO078-13
Subject to change without notice.
www.tridonic.com
7
luxCONTROL lighting control system
basicDIM
Light level recognition area
Sensor alignment
x2
y
x2
y
x1
y
y
x1
αx2 = 22°
αx1 = 38°
αy = 30°
h
h
22°
38°
x2
y
x1
y
h*
x1
x2
y
d
1.7 m
1.3 m
0.7 m
1.0 m
2.8 m
2.0 m
1.6 m
0.8 m
1.2 m
3.2 m
2.3 m
1.8 m
0.9 m
1.3 m
3.7 m
2.5 m
2.0 m
1.0 m
1.4 m
4.0 m
2.7 m
2.1 m
1.1 m
1.6 m
4.4 m
3.0 m
2.3 m
1.2 m
1.7 m
4.9 m
3.5 m
2.7 m
1.4 m
2.0 m
5.7 m
4.0 m
3.1 m
1.6 m
2.3 m
6.5 m
*
The recommended maximum room height for office
applications is 3 m and for corridor applications for
example 4 m. Up to 2 m mounting height presence is
detected and over 2 m motion is detected.
Calculation of the diameter (light area):
x1 = tan(ax1) × h
x2 = tan(ax2) × h
y = tan(ay) × h
Calculation of the diameter (motion area):
d = 2 × tan(0,5 × a) × h
x2
y
y
x1
x2
y
y
x1
Example for light and motion detection
area at height of 1.7 m:
1m
y
0.7 m
x1
x2
y
1.3 m
Light level
recognation area
1m
Presence / motion detection
2.8 m
Presence / motion detection
h
α = 78°
d
Data sheet 04/17-CO078-13
Subject to change without notice.
www.tridonic.com
8
luxCONTROL lighting control system
basicDIM
The following operating modes can be set for the motion detector via the
basicDIM ILD Programmer or DSI-Smart Programmer:
Active
The light is switched on or off automatically depending
on whether or not there is a person in the room.
Off Only
The motion detector only switches the connected
lighting off. The luminaires are switched on manually via
the connected external switch or infra-red control.
Never Off
Inactive
If it has not detected any movement the sensor dims to
the “second light value” parameter and remains at this
value
The motion sensor is deactivated. The light must be
switched on or off manually.
Manual-off delay
If the system is switched off manually via the switch or remote control the
motion sensor is deactivated. At the end of a 10 minutes delay if motion has
not been detected the motion sensor is activated again. If the sensor detects
motion during the “Manual Off” delay, the time will be reset to the start.
The following operating modes can be set for lighting control via the
DSI-Smart Programmer:
Active
Constant light control is active.
Inactive
Constant light control is deactivated.
The lighting is switched on at 100%.
Switch-off delay
This is the time after which the lighting is switched off if no movement is
detected. It can be set via the “time delay” parameter.
The value is set with the “light-level” parameter. If the value is set to “max”
then lighting control is deactivated. For all other values lighting control is
active.
Second light value
On the basicDIM ILD you can set whether the light is to be switched off after
the switch-off delay or dimmed to the second light value. The light value and
the dwell time (how long the value is held) can be set via the “when vacant”
and “sec. level” parameters.
Setpoint adjustment
• DSI-SMART Controller: Pressing the Set button stores the current light
value as a new setpoint.
• basicDIM ILD Programmer or DSI-SMART Programmer:
Via the “light-level” parameter
• External switch: Briefly pressing the switch twice stores the current light
value as a new setpoint. (Function is lockable via the basicDIM ILD
Programmer or DSI Programmer)
Offset
The light level of channel 2 is less then the light level of channel 1.
The difference can be set with the parameter „Offset Value“
via basicDIM ILD Programmer or DSI-SMART Programmer.
Channel 2
Channel 1
40 %
70 %
Bright-out
If the nominal illuminance (e.g. 500 lux) is exceeded for 10 minutes by
more than 150 % (e.g. 750 lux), the lighting is switched off even if motion is
detected. The lighting is switched on again when the measured light value
falls below the setpoint.
The bright-out function is displayed by a green status indication LED at the
sensor.
This function can be deactivated via the basicDIM ILD Programmer or
DSI-SMART Programmer.
500 LUX
Artificial light
Natural light
Data sheet 04/17-CO078-13
Subject to change without notice.
www.tridonic.com
9
luxCONTROL lighting control system
basicDIM
User-definable parameters
basicDIM ILD have the following user-definable parameters (since DSI-SMART Programmer version 2.30):
The values in parentheses are the factory default settings.
The adjustable values for the basicDIM ILD Programmer is available in a separately documentation on www.tridonic.com.
Parameter
Range
(Factory setting)
Description
light-level
1 – 100/max
(70)
time delay
30 s – 60 min/con
(20 min)
Delay time after the last detected movement
The following values can be set:
30 seconds, 1, 2, 3, 5, 10, 15, 20, 30, 45 and 60 minutes and “continuous” (no switch-off)
if vacant
off
30 s – 60 min/con
(off)
The “off” setting switches the luminaire off after the delay time has elapsed.
If a time value is set, the luminaire dims to the “sec. level” parameter and only switches off after the previously set
time has elapsed. The following values can be set:
off, 30 seconds, 1, 2, 3, 5, 10, 15, 20, 30, 45 and 60 minutes and “continuous” (“never OFF” function)
sec. level
1 – 100 %
(1 %)
P.I.R
active/inactive/off
only
(active)
With the “active” setting, the lighting is automatically switched on or off depending whether a person is present.
With the “inactive” setting, the basicDIM ILD/DSI-SMART (PTM) can, in combination with continuous “time delay”,
only be used for lighting control.
With the “off only” setting, the lighting has to be switched on manually (momentary-action switch,
remote control) but is switched off by the presence detector.
bright-out
yes/no
(yes)
With the “yes” setting, the lighting switches off as soon as the light level exceeds 150 % of the set point for longer
than 10 minutes, for instance, if the room is adequately illuminated by sunlight. If the actual value falls below
100 % of the set point, the lighting switches back on again.
With the “no” setting, the lighting remains switched on (at the minimum dimming level) even if the room is
adequately illuminated by sunlight and no artificial lighting is required.
Power up
on/off
(on)
With the “on” setting, the luminaire switches on after a mains break.
With the “off” setting, the luminaire does not switch on after a mains break. The presence detector becomes
active again after 15 seconds.
hold
overwrite
on/off
(off)
If the light level is manually dimmed via a momentary-action switch or remote control, lighting control stops.
The previously set dimming level retains its fixed value as long as lighting control is not activated by manual
intervention (momentary-action switch or remote control). If there is no movement in the room in this state and
the “time delay” has elapsed, the control unit stores the fixed dimming level.
With the “off” setting, lighting control is restarted each time movement is detected.
With the “on” setting, the control unit switches the luminaires back to the fixed dimming level each time
movement is detected and lighting control remains stopped. With this setting, lighting control can be activated
again via the remote control (Automatic button).
If lighting control was active before repeated detection or if the lighting was switched off manually, the luminaires
and lighting control are switched on after movement is detected in order to prevent people having to enter a
dark room.
PTM Set
on/off
(on)
With the “on” setting, it is possible to save the currently set light level as a lighting control set point by pressing
the momentary-action switch twice shortly.
With the “off” setting, this function is disabled.
DALIorDSI
DSI/DALI
(DSI)
Offset Mode
fixed/converging
(converging)
Offset Value
0 to -70 %
(-30 %)
Selectable lighting control set point, 1 – 100 increments.
“max” also makes it possible to set the control gear to full power. (DSI 255)
“man” indicates whether the adjustment value was overwritten by the SET function of the SMART Controller.
Second light level to which luminaire dims after the delay time has elapsed.
(in conjunction with the “if vacant” parameter)
With the “DSI” setting, DSI interface mode is enabled.
With the “DALI” setting, DALI interface mode in which DALI broadcast commands are sent is enabled.
This parameter specifies how the adjustable “Offset Value” of the basicDIM ILD behaves from channel 2 to
channel 1 over the dimming range.
With the “fixed” setting, the previously set “Offset Value” remains the same across the dimming range. (e.g. with
an “Offset Value” of -30 %, channel 2 remains at 70 % when channel 1 has reached 100 %).
With the “converging” setting, the previously set “Offset Value” remains the same up to a specific dimming level
and decreases the closer one gets to 100%. (e.g., with an “Offset Value” of -30 %, the dimming level of channel 2 is
40 % and that of channel 1 is 70 %. but both channels simultaneously change to a dimming level of 100 % if
the lighting is dimmed up).
Adjustable brightness difference between channel 2 and channel 1 of the basicDIM ILD.
The following values can be set:
0 %, -10 %, -20 %, -30 %, -40 %, -50 %, -60 % and -70 %
Data sheet 04/17-CO078-13
Subject to change without notice.
www.tridonic.com
10
luxCONTROL lighting control system
basicDIM
Default Parameter Motion Detector
Parameter
Alight-level
1 time delay
B sec. level
2 if vacant
Data sheet 04/17-CO078-13
Subject to change without notice.
www.tridonic.com
11
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement