Keypad
INSTALLATION INSTRUCTIONS
May 2016
Table of Contents
Introduction......................................................................................................................... 3
Specifications ..................................................................................................................... 4
WEK200, WEK200L and WEK Board ................................................................................. 5
 WEK200............................................................................................................................................... 5
 WEK200L............................................................................................................................................. 5
 WEK Board .......................................................................................................................................... 5
Wiring .................................................................................................................................. 6
 WEK Board .......................................................................................................................................... 6
 WEK200............................................................................................................................................... 7
 WEK200L............................................................................................................................................. 8
Programming the System Code......................................................................................... 9
Keypad Usage ..................................................................................................................... 9
 2008 - 2016 Cansec Systems Ltd.
All rights reserved.
Keypads
Installation Manual
Page 2 of 9
May 2016 • Rev. 1.5
Introduction
Cansec’s Wiegand Emulating Keypad emulates standard 26-bit or Cansec 37bit Wiegand format by allowing users to use an existing access user ID as a
Personal Identification Number (PIN). A site code can be programmed into
the keypad via the number pad.
There are two models of Keypad: Heavy Duty (WEK200) and Light Duty
(WEK200L). The WEK200 faceplate and keys are made of stainless steel to
withstand harsh use. The WEK200L faceplate and keys are made of durable
plastic – a more cost effective option for lighter uses. Both keypads are sealed
against dust and resistant against water damage.
NOTE: Tech Support will only be provided where product installation guidelines
have been followed.
Keypads
Installation Manual
Page 3 of 9
May 2016 • Rev. 1.5
Specifications
Warranty ................................................................................................ one year
Operating Voltage ..........................................................................5 to 14 VDC
Current Draw .................................................................................. 50 mA max
Output Format ............................................... 26-bit & Cansec 37-bit Wiegand
Operating Temperature
WEK200: ............................................... -40°C to 70°C (-40 °F to 158 °F)
WEK200L: ................................................-10°C to 70°C (14°F to 158°F)
Dimensions .................................... 99.5 mm (w) x 118.5 mm (h) x 8 mm (d)
...................................................... [ (3.92 in (w) x 4.67in (h) x 0.31in (d) ]
Weight
WEK200: ..............................................................approx. 450 g (15.9 oz)
WEK200L: ................................................................ approx. 88 g (3.1 oz)
Colour
WEK200: ................................................................... silver (stainless steel)
WEK200L: ............................................................................ black (plastic)
Casing
WEK200: ................................................................ chromed die-cast zinc
WEK200L: ........................................................... general-service polymer
Mounting .................................................................... single-gang electrical box
Environment .............................................................................indoor; outdoor
Rated IP
(65) WEK200: water/dust-sealed (when mounted to suitable enclosure)
(54) WEK200L: water/dust-sealed (when mounted to suitable enclosure)
LED ....................................................................bi-colour standard (red, green)
Beeper ................................................................................................... standard
Cable........................................................ 7 conductors, 22 AWG, stranded
.................................... overall shield for 1 line LED and sonalert control
..................................................... 150 m (500 ft) max length to controller
*Specifications subject to change without notice.
Keypads
Installation Manual
Page 4 of 9
May 2016 • Rev. 1.5
WEK200, WEK200L and WEK Board
WEK200
FRONT
BACK
WEK200L
FRONT
BACK
WEK BOARD
Keypads
Installation Manual
Page 5 of 9
May 2016 • Rev. 1.5
Wiring
WEK BOARD
The image below shows the wiring colours and the orientation of the seven
(7) conductors interface cable from the WEK board to the access controller.
Keypads
Installation Manual
Page 6 of 9
May 2016 • Rev. 1.5
WEK200
The image below shows the wiring colours and the orientation of the
connectors with respect to the WEK200 keypad and the WEK board.
Keypads
Installation Manual
Page 7 of 9
May 2016 • Rev. 1.5
WEK200L
The image below shows the wiring colours and the orientation of the
connectors with respect to the WEK200L keypad and the WEK board.
Keypads
Installation Manual
Page 8 of 9
May 2016 • Rev. 1.5
Programming the System Code
IMPORTANT:
1. The pound sign (#) must be entered after a system code is entered or
else all inputs are ignored.
2. For 26-bit Wiegand output, enter a number from 0 to 255 followed by
the # key and a long beep will sound.
3. For 37-bit Wiegand output (Cansec proprietary format), enter a
number from 256 to 32767 followed by a # key and a long beep will
sound.
4. The LED indicator should now turn solid RED and the programming
is finished.
NOTE: The unit comes from Cansec in factory default mode (LED flashing
RED and GREEN) without a programmed system code.
If for some reason, the unit is not flashing RED and GREEN (it is not in
factory default mode), temporarily short the two pins (jumper P1) with pliers
or a screw driver. This will reset the unit to factory default mode and the unit
will begin to flash RED and GREEN. Follow steps 1 through 3 to program.
Keypad Usage
Keypad usage: enter a PIN number between 1 and 65534 follow by “#”