Intel Rail Enabling Kit for Kontron Communications Rackmount

Intel Rail Enabling Kit for Kontron Communications Rackmount
TMLREK01 Rail Enabling Kit Intel Rail Enabling Kit for
Kontron Communications Rackmount Servers
TMLREK01
This kit provides a method for enabling the use of the Intel rail kits AXXBASRAIL13
and AXXHERAIL2 with a Kontron Communications Rackmount Server. Please
consult the Intel kit instructions where indicated.
Resources


Basic Rail Kit Install Guide for Intel Server Chassis for the basic rail kit AXXBASRAIL13 is
included in the kit or as of June 2009 can be found online on Intel’s website.
Rail Kit Installation sheet for the rail kit AXXHERAIL2 is included in the kit only.
Tools and supplies needed

3/8-inch hex driver or wrench

#2 Phillips screwdriver
Contents of the kit
This package contains 10 TMLREK01 kits in an overpack (10 kits per box). Each kit contains:

Four hex head shoulder screws


Two #10-32 x 3/8” screws
Two rack mounting ears
Note: The installation instructions apply to both 1U and 2U servers.
June 2009 Order Number: K00032‐001 Intel Rail Kit Enabling for Kontron Communications Rackmount Servers Installation Guide, rev. 1.0 1 TMLREK01 Rail Enabling Kit Instructions for mounting the server using the Intel basic rail kit
AXXBASRAIL13
1.
2.
Remove the Inner Rails and Install Outer Rails to Rack: Following Intel’s Install Guide,
remove the inner rails from the rail assembly and install the outer rail slides to the rack posts.
Install Shoulder Screws: Install two hex head shoulder screws supplied in the Kontron kit on
each side of the server.
Figure 1. Install shoulder screws June 2009 Order Number: K00032‐001 Intel Rail Kit Enabling for Kontron Communications Rackmount Servers Installation Guide, rev. 1.0 2 TMLREK01 Rail Enabling Kit *Note: Some Kontron communications rackmount servers share the same sheet metal chassis
for multiple length products. On these products, there are 2 sets of holes for attaching the
inner rail.
For 20 inch servers with a single set of rail kit attachment holes, install the shoulder screws
into the holes indicated.
Figure 2. Server with single set of rail attach holes, 20 inch For 24 inch servers with multiple sets of rail kit attachment holes, install the shoulder screws
into the holes marked as “AA”.
Figure 3. Server with multiple sets of rail attach holes, 24 inch For 20 inch servers with multiple sets of rail kit attachment holes, install the shoulder screws
into the holes marked as “A”.
Figure 4. Server with multiple sets of rail attach holes, 20 inch June 2009 Order Number: K00032‐001 Intel Rail Kit Enabling for Kontron Communications Rackmount Servers Installation Guide, rev. 1.0 3 TMLREK01 Rail Enabling Kit 3. Attach Inner Rails to Server: Install the inner rails onto the hex head shoulder screws and slide
the inner rails forward.
Figure 5. Install rails to server 4. Install screws to secure inner rails: Secure the inner rails with the screws indicated in Intel’s
Install Guide.
Figure 6. Secure rails to server June 2009 Order Number: K00032‐001 Intel Rail Kit Enabling for Kontron Communications Rackmount Servers Installation Guide, rev. 1.0 4 TMLREK01 Raill Enabling Kit 5.
Attac
ch Rack Mou
unting Ears: Attach the rack
r
mounting ears to eac
ch side of the
e server using
g the
#10-3
32 x 3/8 scre
ews provided in the Kontro
on kit.
Figure
e 7. Attach rackk mounting eaars 6.
Insta
all the Serve
er into the Rack:
R
Install the server in
nto the rack and
a
secure it with the scre
ews
indica
ated in Intel’s
s Install Guide.
June 2009 Order Number:: K00032‐001 Inntel Rail Kit Enabling for Kontron Communications Rackmount Servers Installation Guidee, rev. 1.0 5 TMLREK01 Rail Enabling Kit Instructions for mounting the server using the Intel rail kit
AXXHERAIL2
1.
2.
Install Slide Rails in Rack: Following the instruction sheet included with the Intel rail kit, install
the slide rails in the rack.
Install Shoulder Screws: Install two hex head shoulder screws supplied in the Kontron kit on
each side of the server.
Figure 8. Install shoulder screws June 2009 Order Number: K00032‐001 Intel Rail Kit Enabling for Kontron Communications Rackmount Servers Installation Guide, rev. 1.0 6 TMLREK01 Rail Enabling Kit *Note: Some Kontron communications servers share the same sheet metal chassis for multiple
length products. On these products, there are 2 sets of holes for attaching the inner rail.
For 20 inch servers with a single set of rail kit attachment holes, install the shoulder screws into
the holes indicated.
Figure 9. Server with single set of rail attach holes, 20 inch For 24” servers with multiple sets of rail kit attachment holes, install the shoulder screws into the
holes marked as “AA”.
Figure 10. Server with multiple sets of rail attach holes, 24 inch For 20” servers with multiple sets of rail kit attachment holes, install the shoulder screws into the
holes marked as “A”.
Figure 11. Server with multiple sets of rail attach holes, 20 inch June 2009 Order Number: K00032‐001 Intel Rail Kit Enabling for Kontron Communications Rackmount Servers Installation Guide, rev. 1.0 7 TMLREK01 Raill Enabling Kit 3.
Insta
all Server to
o Slide Rails: Following In
ntel’s Rail Kitt Installation sheet, fully extend
e
both slide
s
rails, align the four hex head shoulder screw
ws with the mating
m
featurres on the raiils, and installl the
server into the slid
de rails.
4.
ck: Rotate th
he spring lock
k down and hold
h
it in this rotated posittion.
Rotatte spring loc
Figure
e 12. Rotate sp
pring lock June 2009 Order Number:: K00032‐001 Inntel Rail Kit Enabling for Kontron Communications Rackmount Servers Installation Guidee, rev. 1.0 8 TMLREK01 Raill Enabling Kit 5.
Attac
ch Rack Mou
unting Ears: While holdin
ng the spring lock in its ro
otated positio
on, attach the
e rack
moun
nting ears to the
t
side of th
he server usin
ng the #10-3
32 x 3/8 screw
ws provided in the Kontro
on kit.
Figure
e 13. Attach rack mounting e
ears 6.
Insta
all and Secure Server to
o Rack: Using Intel’s Slide
e Rail Kit Ins
stallation shee
et, slide the
server chassis into
o the rack and secure it us
sing the two screws indica
ated in the In
ntel rail kit.
June 2009 Order Number:: K00032‐001 Inntel Rail Kit Enabling for Kontron Communications Rackmount Servers Installation Guidee, rev. 1.0 9 