1) Connecting wires and mounting thermostat
Connect the rear thermostat wires to the 240 V LINE and to the load using
solderless connectors for copper wires. See schematic diagram.
Push the excess wire back into the electrical box to prevent interference with the
thermostat. Secure the thermostat using two (2) 6-32 screws. Once the
thermostat is properly installed, return power to heating system.
470 Beauty Spot Rd. East
Bennettsville, SC 29512 USA
MODEL TH110A-DP-P
BEFORE
AFTER
SUMMARY
u
OPTIONS SELECTION
At the back of the thermostat, there are 3 selection switches to set at
your preferences.
B
Temperature in °C or °F, time in 12 or 24 hours and Early Start function.
240 VAC
u
TO SET TIME AND DAY
Press on DAY, HOUR and MIN buttons to adjust time and day.
u
TO RECORD THE
(COMFORT) SETPOINT TEMPERATURE
Select chosen setpoint temperature by using
or
button. Press on
button (2 to 3 seconds) until icon appears on display.
u
TO RECORD THE
(ECONOMY) SETPOINT TEMPERATURE
Select chosen setpoint temperature by using
or
button.
Press on button (2 to 3 seconds) until icon appears on display .
u
TO RECORD THE
(VACATION) SETPOINT TEMPERATURE
To program the Vacation temperature, select the desired degree using the
buttons and press on the
and
buttons simultaneously
until the
icon is displayed (app. 3 seconds).
u
OPERATING MODES
To select an operating mode, use MODE button.
AUTO:
MAN:
Runs the program.
or
shows temperature setting
and can override temporarily your programming up to the
next program.
Maintains the selected temperature.
the temperature setting.
or
B
B
60 HZ
B
Note 1: All cables and connections must conform to the local electrical code.
WARNING: Special CO/ALR solderless connectors must be used when
connecting with aluminum conductors.
Power-up
To power up thermostat:
Set the On/Off switch to On.
changes
When power is applied for the first time, the
display must show the time 00:00, the room
temperature and the Manual mode icon (
).
Other information might show up on the display if
installation is defective or does not comply with the
instructions.
Note: The On/Off switch set to Off will place the
thermostat in sleep mode. Ideal for summertime.
OPERATING MODES
The TH110A-DP-P has two (2) operating modes.
MANUAL (
)
This mode allows you to maintain a constant temperature in the room.
1- To activate this mode, press on Mode button to display the
2- Set the desired temperature using the
pre-programmed
or
or
settings.
(To select the
setting, press on
and
AUTOMATIC (
icon.
buttons or select the
simultaneously.)
)
This mode executes your own programming.
To activate this mode, press on Mode button to display the
icon.
The
or
icon indicates which temperature setting is used. Also, the icon
of the program number will be shown.
Memory back-up
INSTALLATION
NOTE: The "Problems and Solutions" section at the end of this user's guide will
help you to correct your problems during the installation.
This thermostat has been designed to operate with any installation
which has a RESISTIVE load not exceeding 4000 W (16.67 A) @ 240 VAC
such as electric baseboards, radiant ceilings and floors, electric con
vectors, etc. It is not compatible with a low voltage controller used by
a central heating system.
In the event of a power failure, an internal circuit will maintain the programming
and the time. But only the time could have to be set if power failure is more than
2 hours.
Early Start function
The thermostat is providing a built-in function enabling it to calculate the
optimum time to start the heating system to achieve the desired temperature
setting at the programmed time. This function could start the heating system as
early as 6 hours prior to the programmed time. To enable this function, set the
switch E.S. to “ON” at the back of the thermostat.
Electricians or experienced technicians should install the thermostat.
This thermostat is designed to be used with a self-protected heating
system equipped with thermal cut off and circuit breaker.
PROGRAMMING
Programming the time and day
PARTS INCLUDED
1-Set the time using the Hour and Min buttons.
2-Set the day using the Day button.
- One (1) TH110A-DP-P (240 VAC) thermostat
- Two (2) 6-32 screws
- Four (4) solderless connectors (for copper wire)
Programming the Comfort, Economy and Vacation settings
TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER
PANEL TO AVOID ELECTRICAL SHOCK. Keep air vents of the thermostat clean
and free from obstructions.
The Comfort
, Economy
and Vacation
settings respectively represent
the temperatures that you wish to have during the day
, at night or while you
are away at work
, or while you are away for an extended period
.
920-110-005-00-1-0 1/3
To program your settings
To modify the Saturday and Sunday schedules:
a)
6- Press on Day button until SA or SU is displayed.
b)
To program the Comfort temperature, select the desired degree using the
buttons and press the
button until the
icon is displayed
(app. 3 seconds).
To program the Economy temperature, select the desired degree using the
buttons and press the
button until the
icon is displayed
(app. 3 seconds).
c)
To program the Vacation temperature, select the desired degree using the
buttons and press on the
and
buttons simultaneously
until the
icon is displayed (app. 3 seconds).
d)
Press the Mode button to exit this function and return to the normal
operating mode.
Schedule programming
7- Press on PGM button to select Prog. 1 (
buttons to enter 7:30 AM.
) and Hour and Min
8- Press on PGM button to select Prog. 2 (
erase it.
) and then Clear button to
9- Press on PGM button to select Prog. 3 (
erase it.
) and then Clear button to
10- Press on PGM button to select Prog. 4 (
buttons to enter 11:00 PM.
) and then Hour and Min
11- Press on Mode button to exit this function.
Temporary or permanent temperature bypass
The TH110A-DP-P allows 4 setting changes for each day of the week. There are
no pre-set programs.The programs are tailored to perfectly adapt to your life
style. The principle is very simple. For each day, enter the time at which you wake
up (P1), the time you leave for work (P2), the time you arrive back home (P3) and
the time you go to bed (P4).
Mode
Program
You can also switch to the Vacation setting for a prolonged absence by pressing
on
and
at the same time.The display will show
icon. In that case,
the derogation is permanent. To return to the normal operating mode, press on
Mode button.
Time
1
Wake-up time
2
Leaving time
3
Return time
4
Bed time
This operation allows you to temporarily modify the room temperature while you
are in the Automatic mode. Simply press on
or
button to select the desired
temperature, or the
or
button to select the Comfort or Econo settings you
have programmed.This temperature will be maintained until the beginning of the
next programmed schedule.
If you wish to immediately return to the programmed settings, press on Mode
button twice.
CHARACTERISTICS
For savings to be obtained, you must lower the temperature for a period of 2 to 3
times the delay required to bring the temperature back to your comfort level.
• Model:
TH110A-DP-P (240 VAC)
• Supply:
240 VAC, 50/60 Hz
• Load:
16.67 A maximum (resistive only)
• Power:
4000 watts (NI) @ 240 VAC
• Approvals:
CSA / UL
• Display range:
0 to 60 °C (32 to 140 °F)
• Setting range:
5 to 30 °C (40 to 85 °F)
• Comfort default setting:
20 °C (68 °F)
• Econo default setting:
18 °C (64 °F)
3- Press on PGM button to select program 1, 2, 3 or 4.
• Vacation default setting:
10 °C (50 °F)
4- Press on Hour and Min buttons to program the time.
• Storage:
-20 to 50 °C (-4 to 120 °F)
5- When you have completed your programming, press on Mode button
to exit this function.
WARRANTY
Example : If your system takes one hour to go from your saving temperature level
to your comfort temperature Ievel, it is useless to lower the temperature for a
period less than 2 to 3 hours.
a) To Program your Schedule
1- Press on PGM button to access the programming mode.
2- Press on Day button to select the day to be programmed. You can select
all days of the week by pressing on Day button for 3 seconds.
b) To Erase a Program :
Select the program using PGM and Day buttons, and press on Clear
button. The time field displays --:-- when the program is inactive.
c) Example 1 : Comfort period from 7:00 AM to 10:30 PM
Economy period from 10:30 PM to 7:00 AM
Identical schedule for all days of the week.
1-
Press on PGM button to access the programming mode.
2-
Press on Day button 3 seconds to select every day of the week.
3-
Press on Hour button to enter 7:00 AM, Prog. 1 (
4-
Press on PGM button again to select Prog. 2 (
Hour and Min buttons to enter 10:30 PM.
5-
Press on Mode button to exit this function.
The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs and shipping costs incurred to return
products to Marley Engineered Products Service Center. Within the limitations of
this warranty, inoperative units should be returned to the nearest Marley authorized service center or the Marley Engineered Products Service Center and we will
repair or replace, at our option, at no charge to you with return freight paid by
Marley. It is agreed that such repair or replacement is the exclusive remedy available from Marley Engineered Products. If the product requires replacement, but
an identical model is no longer available, Marley Engineered Products will select
a comparable item.
).
), and press on
d) Example 2 : Comfort period: Monday to Friday from 6:15 AM to
8:15 AM and from 5:00 PM to 10:00 PM.
Saturday & Sunday from 7:30 AM to 11:00 PM.
Schedule/Day
MON.
TUES.
WED.
THU.
FRI.
SAT.
SUN.
PROG. 1
6:15 AM 6:15 AM 6:15 AM 6:15 AM 6:15 AM 7:30 AM 7:30 AM
PROG. 2
8:15 AM 8:15 AM 8:15 AM 8:15 AM 8:15 AM
---
---
PROG. 3
5 PM
5 PM
5 PM
5 PM
5 PM
---
---
PROG. 4
10 PM
10 PM
10 PM
10 PM
10 PM
11 PM
11 PM
NOTE :
All products manufactured by Marley Engineered Products are warranted against
defects in workmanship and materials for one year from date of original installation or 18 months from date of manufacture, except special components as noted
below which are warranted against defects in workmanship and materials (see
medallion levels below) from date of installation.This warranty does not apply to
damage from accident, misuse or alteration; nor where the connected voltage is
more than 5% above the nameplates voltage; nor to equipment improperly
installed or wired or maintained in violation of the products installation instructions. All claims for warranty work must be accompanied by proof of the installation or purchase.
It is faster to program the same schedule for every day and then
modify the exception days.
the above warranties are in lieu of all other warranties expressed or implied and
all implied warranties of merchantability and fitness for a particular purpose which
exceed the aforesaid expressed warranties are hereby disclaimed and excluded
from this agreement. marley engineered products shall not be liable for consequential damages arising with respect to the product, whether based upon negligence, tort, strict liability or contract.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary
from state to state.
For the address of your nearest authorized service center, contact Marley
1- Press on PGM button to access the programming mode.
2- Press on Day button 3 seconds to select every day of the week.
3- Press on Hour and Min buttons to enter 6:15 AM, Prog. 1 (
4- Press on PGM button to select Prog. 2 (
enter 8:15 AM.
).
Engineered Products in Bennettsville, SC, at 1-800-642-4328 .
Merchandise returned to the factory must be accompanied by a return authorization and service identification tag, both available from Marley Engineered
Products. When requesting return authorization, include all numbers shown on
the products.
) and Hour and Min buttons to
5- Repeat step 4 to enter Prog. 3 (5:00 PM) and Prog. 4 (10:00 PM).
NOTE : When making modifications, make sure you are in the right
program.
05/02/02
920-110-005-00-1-0
2/3
PROBLEMS AND SOLUTIONS
PROBLEMS
CAUSES
SOLUTIONS
No display
• Circuit breaker is open
• Power failure
• The thermostat switch is
in Off position
• Check 240 VAC presence
at the thermostat
• Put the switch
in On position
The thermostat is loosing
the time but not the programming
• Power failure more than
2 hours
Room temperature shown is wrong
• A draft is nearby the thermostat
• Eliminate the draft
Heating system always on
• Bad installation
• Check installation
The thermostat displays heating
but heating system is not turned on
• Bad installation
• Check installation
• Check 240 VAC presence
at the heating system
Programs do not change as you want
• Incorrect programming hours
• Wrong programming mode selected
• Check actual time
in AM & PM as well
as program times
(AM is not displayed)
• Make sure operating mode
is set to AUTO
PROBLÈMES ET SOLUTIONS
PROBLÈMES
CAUSES
SOLUTIONS
Pas d'affichage
• Disjoncteur ouvert
• Panne de courant
• L’interrupteur du thermostat
est en position Off
• Vérifiez la présence
du 240 Vca au thermostat
• Placez l’interrupteur en
position On
Le thermostat perd l'heure
mais pas la programmation
• Panne de courant de longue
durée (plus de 2 heures)
Affichage de la température ambiante
incorrect
• Courant d'air à proximité
• Éliminez les courants d'air
Système de chauffage toujours
en marche
• Mauvaise installation
• Vérifiez l'installation
Le thermostat affiche du chauffage mais le
sytème de chauffage
ne chauffe pas
• Mauvaise installation
• Vérifiez l'installation
• Vérifiez la présence du
240 Vca au système de chauffage
Les programmes ne changent pas comme
vous le souhaitez
• Heures de programmation
incorrectes
• Mauvais mode d'opération
sélectionné
• Vérifiez les heures actuelles
de programmation
(attention au format AM
et PM, AM n'est pas affiché)
• Assurez-vous que vous avez
choisi le mode d'opération
AUTO
PROBLEMAS Y SOLUCIONES
PROBLEMAS
CAUSAS
SOLUCIONES
La pantalla no marca
• Disyuntor abierto
• Corte de corriente eléctrica
• El interruptor se encuentra en Off
El termostato pierde la hora pero
no la programación
• Pérdida de corriente de larga duración
(más de 2 horas)
Marca la temperatura ambiente incorrecta
• Corriente de aire a proximidad
• Elimine la corriente de aire
Sistema de calefacción siempre en marcha
• Mala instalación
• Verifique la instalación
El termostato marca la calefacción pero el
sistema de calefacción no calienta
• Mala instalación
• Verifique la instalación
• Verifique la presencia del
240 Vca en el sistema de calefacción
Los programas no cambian como usted
desea
• Horas de programación incorrectas
• Selección de un modo de operación erróneo
• Verifique las horas de programación
actuales (cuidado con el ciclo
AM y PM, AM no aparece
en pantalla)
• Asegúrese de haber elegido
el modo de operación AUTO
11/06/01
• Verifique la presencia de 240 Vca
del termostato
• Colóquo en On
27/11/01
920-110-005-00-1-0
3/3