Your Plastic Rotary Pump is built to these high quality specifications

Your Plastic Rotary Pump is built to these high quality specifications
Thank you for purchasing your PLASTIC ROTARY PUMP. Please read instructions before using product and save for future reference. Observe
all safety information, warnings, and cautions when using this product. Failure to comply with instructions could result in persona injury and/or
damage to product or property. Use for pumping aggressive chemicals including solvents, hydrocarbons and fuel. NOTE: This is a general
service instruction sheet & specifications described may not match your dispenser exactly.
PLASTIC ROTARY BARREL PUMP
Your Plastic Rotary Pump is built to these high quality specifications.
• Pump body, outlet and suction tube are made from glass filled polypropylene.
• Veins are made from Ryton high performance resin.
• Seals used in the pump are made from Viton rubber.
• All pump hardware is stainless steel.
Additional Specifications
Pump delivers 1.3 gal / 20 turns (5 litre).
Assembly & Operation
Assemble the 2 parts of the Discharge spout
together & fasten the assembly onto the outlet
on the main pump body
Affix the pump handle onto the crank &
connect the crank to the crankshaft on the
pump body. Secure the connection using the
bolt provided. Make sure that the bolt fits
onto the depression in the crankshaft
Assemble the suction tube parts, depending upon the
drum size on which the pump is to be installed. The
suction tube part with the strainer may be connected
direct onto the pump inlet or assembled with one
extension or both extensions. All 3 parts must be
connected for use with 55-gallon drums. Use a
sealant to connect the suction tube parts for a totally
leak-proof connection.
PRP
Choose the bung adapter that best fits your drum.
Each pack comes with two adapters, which have slight
difference in the threads to suit different drums (metal
& plastic). Slide the selected 2” bung onto the tube
from the top end & tighten the suction tube onto the
inlet on the main pump body. Use a thread sealant to
connect the suction tube parts for a totally leak-proof
connection.
Insert the pump assembly into the drum
from the 2” bung opening on the drum.
Once the bottom of the pump
touches the base of the drum,
securely fasten the bung onto the
drum. Now very lightly tighten the
bung onto the suction tube
Take an empty container & place it below the
discharge spout. Start rotating pump handle. Within
a maximum of 7 rotations, pump will be primed &
will start dispensing fluid. In a rare case, where the
pump does not get primed reverse the outlet
discharge spout on the pump & pour about 30 ml of
any oil into the outlet & pump the handle for about 7
rotations.
Once you have completed pumping the liquid, invert
the discharge spout sideways for a non-drip operation.
If the pump is re used after an extended period of time, it may loose its prime & need re-priming, follow Step 7
COMPATIBILITY CHART
Liquid
Acetaldeyde aq.
Acetic acid aq.
Acetone
Aluminum chloride aq.
Aluminum sulphate aq.
Ammonia gas
Ammonium chloride aq
Amyl Alcohol
Aniline
Antifreeze
Barium chloride aq.
Benzene
Boric acid aq
Butyl Alcohol
Carbon tetrachloride
Chloroform
Chromic acid aq.
Citric acid aq.
Cresylic acid
Cyclohexanol
Cyclohexanone
Detergent
Diesel
Ethers
Ethyl acetate
Ethylene dichloride
Ethylene Glycol
Formaldehyde aq.
Freon 12
Fuel Oil
Glycerine
Compatibility
No
No
No
Yes
Yes
No
Yes
No
No
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes
No
No
No
Yes
Yes
No
No
No
Yes
No
Yes
Yes
Yes
Liquid
Hydrobromic acid aq.
Hydrogen peroxide aq.
Hydrogen sulphide aq.
Isopropyl Alcohol
Kerosene
Lacquer
Magnesium chloride aq.
Methyl chloride
Methyl ethyl ketone
Mineral Oils
Napthalene
Nickel sulphate aq.
Oxalic acid aq.
Ozone
Petrol
Phenol
Potassium chloride aq.
Soap Solutions
Sodium nitrate aq.
Solvents
Stearic acid
Sulphuric acid aq.
Toluene
Transformer Oil
Transmission Fluid
Trichloroethylene
Turpentine
Vinyl chloride
Water
Xylene
Compatibility
No
Yes
No
Yes
Yes
No
Yes
No
No
No
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
No
Yes
Yes
No
Yes
Yes
No
No
No
Yes
No
Note: Use of this equipment to pump other than approved fluids will void the manufacturing warranty.
Warning: Never operate the pump near fire or source of spark. Some fluids may be explosive and dangerous to pump.
Made In India
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement