OSD Menu Setting
MINI SPEED DOME CAMERA
10X Mini Speed Dome Camera
Instruction Manual
Rev 1.01 dated on Dec.04, 2006
CONTENTS
Warning & Caution
3
What’s in the Box?
3
General Features
Names of Each Part
4
5
Installation
A. Connection Methods
B. Ceiling Mount Type
6
7
C. Embedded Mount Type
Quick Operating Keys
Diagnostic
8
9
OSD Menu Setting
A. OSD Menu Table
10
B. DOME SET
11
C. CAMERA SET
16
D. PRESET
18
E. AUTO SCAN
19
F. TOUR SET
20
G. PRIVACY SET
21
H. PATTERN SET
22
I. ALARM SET
23
J. SECTOR SET
24
DIP Switch Setting
A. ID Setting (DIP SW1)
B. Protocol/ Baud Rate Setting (DIP SW1-9~10)
Trouble Shooting
25
26
27
Specification
28
Dimension
29
2
WARNING & CAUTION
If you fail to read this information and
handle the product incorrectly, death or
serious injury may occur.
The unit should be installed by the trained
Personnel.
Always stop using when the product emits
smoke or abnormal heat.
Never install the product in area exposed to
water, oil or gas.
This symbol is intended to alert the user to
the presence of un-insulated “dangerous
voltage” within the product’s enclosure that
may be of sufficient magnitude to
constitute a risk of electric shock to
persons.
Never install the product on a ceiling that
cannot hold its weight.
This symbol is intended to alert the user to
the presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the appliance.
Never touch the power cord with wet hands.
Clean only with dry cloth.
Warning
Never install the product in extreme high or
low temperature.
Never move Pan/Tilt by hands.
It may
causes serious damage to the camera.
Never drop hit strongly nor vibrate the
product.
Never expose the product to direct sunlight
or severe ray.
What’s in the Box ?
1. Camera
2. Screws ( Ø4x16 screw
Never touch the front glass of the product.
5EA )
3. Terminal block (5pin 2EA)
4. Manual
Never install the product in areas exposed to
5. Screw Cap (2 EA)
rain or water
3
GENERAL FEATURES
100X Zoom Mini Speed Dome
Quick Operation Keys
10X Optical Zoom with 10X digital zoom
This camera provides quick functional keys in other to be
easily controlled by any other controller or DVR.
±0.02° dome system accuracy with 1/4
micro step
Various Surveillance Functions
With 0.1° technical accuracy, camera provides excellent
sensitive and delicate controlling on preset mode by
adapting 1/4 micro step and twin gear system
Auto Scan repeats pan and tilt between two preset
360° Endless Rotation
10X mini speed dome is capable of endless rotation of 360
degrees
Compensation function: preset position
The function provides absolute preset position even if the
camera is moved by low-frequency vibration, wind and any
impact.
Over 200°/Sec Preset Speed
The 360° full pan function moves through a maximum of
200°/sec., enabling you to quickly pinpoint the spot you
want to watch. Tilt speed provides through a maximum
200°/sec on preset.
Polarity Protection of Power (DC12V)
This protection function prevents the power board from
being out and trouble when power source falsely connects
to the power terminals.
Filter changeable True Day/Night
Surveillance with optimum picture is possible owing to filter
changeable Day/Night (ICR block filter) function and DSS.
Auto IR cut filter removable function is auto controlling the
operation such as color picture plus infrared cut filter during
the day and black and white picture plus filter elimination at
night.
Indoor / Outdoor applications
Compact and minimize dome size provides various install
application to big shop, shopping center, airport, highway
and so on.
positions with different speed and dwell time.
8 Group Tour up to 8 Programmable Group tours
available and each group is consisting up to 60 presets
step with different speed and dwell time with 16
characters.
165 Preset positions up to 165 programmable
preset positions are available with 16 characters
8 Patterns up to 8 programmable user-defined patters
are available with 16 characters and each one is
consisting 50 seconds, total 400 seconds.
8 Sectors up to 8 programmable user-defined sectors
are available with 16 characters
4 Privacy Masking Zones up to 4 programmable
user-defined privacy masking zones are available with
16 characters
4 Alarm input up to 4 alarms activate with preset,
tours, patterns.
150°/S – Manual speed
This camera provides up to 150°/sec of manual speed
and it’s adjustable from 100°/sec to 150°/sec by each
10°/sec
1/4” Sony Super HAD CCD
Equipped with Sony Super HAD CCD technology, these
particular camera provide excellent sensitivity and low
smear levels.
Intelligent Pan/Tilt Controlling
Intelligent Pan/Tilt function is continually decreases pan
and tilt speeds in proportion to zoom.
Aluminum case and PC cover
Elegance designed aluminum body and Poly
Carbonated dome cover prevent weather proofed install
environment (IP66 Rated)
.
Password Protection
4
NAMES OF EACH PAR T
1. Surface Mount Adaptor
2. Cap Screw ( PT3/4 , 2EA )
3. Dip Switch
4. Terminal Block
5. Main body
5
INSTALLATION
A. CONNECTION MATHOD
A-1
1.
2.
3.
4.
5.
6.
Loose the screws on the domes cover and remove it from the base.
(Screws won’t be removed)
Loose the screws which connect mount cover and Main base and separate dome cover from the
main base. (Screws won’t be removed)
Connect power (DC12V 1.5 A) to Power and GND.
Connect video to Video and GND.
Connect communication cable to RS-485 connectors.
Connect alarm cable to GND like 1 and GND, 2 and GND, 3 and GND, 4 and GND.
(You can use both N.O / N.C methods.)

Don’t screw too tightly. It can be the cause of defect.
6
INSTALLATION
B. CEILING MOUNT TYPE
1. Fix the surface mount adaptor with 4pcs of screws on the place where you want to
install. (FIG.4)
2. When you use pipe, please note the standard size of pipe. (FIG.5)
3. You can re-assemble the domes.
7
QUICK OPERATING KEYS
This dome provides three protocols mainly as Pelco D, Pelco P.
These protocols are able to use with other DVR or Controller if the equipment has the above protocols.
Default setting of this dome is Pelco D / P (auto detection) with 2400 bps (baud rate).
As the merit of this product, it has lots of function keys to support the following functions.
1-64 + preset and 100~200 + preset are used for preset and 65-99 + preset used for functions.
For example, to enter OSD MENU, press the button 95 +PRESET.
<Quick Operation Key Table 1, Pelco - D, P>
Number
1 ~ 64, 100~200 +Preset
65 + Preset
66 +Preset
67 +Preset
71~78 +Preset
81~88 +Preset
91 + Preset
92 + Preset
93 + Preset
94 + Preset
95 + Preset
96 + Preset
97 +Preset
Note
PRESET
PRESET STATUS
AUTO SCAN
AUTO FLIP
GROUP TOUR
PATTERN
ZERO POSITION
FREEZE
BLC MODE
D/N MODE
OSD MAIN MENU
FOCUS ADJUST
ALARM
Function
Executing Preset 1 ~ 64
Display Preset Status
Executing Auto Scan
Selectable On/Off/Auto in Auto Flip function
Executing Group Tour #1 ~ #8
Executing Pattern #1 ~ #8
Searching Pan / Tilt Zero Position
Select Freeze image when camera is working
Selectable On/Off in BLC function
Selectable Day/Night Mode (Auto/Day/Night Mode)
To enter OSD Main Menu
Focus adjusting
Selectable Enable/Disable all Alarms
<Quick Operation Keys Table 2> Use these function keys if controller has these keys>
Menu
Tilt Up / Down
Pan Left / Right
Focus Near
Focus Far
Zoom Tele
Zoom Wide

Function
Sub menu cursor moves up / down
Enter to the sub menu or status change or decrement
Using for Enter key when user select YES or NO
Using for function changing keys when set coordinate
Status cursor to the right
Status cursor to the left
65 + preset:” Status Report” is displayed, if user wants to remove this screen, press Focus
Near button.

92 + preset: This feature is possible to freeze the current monitoring image during tour, auto
scan or pattern operation. When press 92 + preset button, the image is suddenly freeze but
the camera is still working as per operation such as tour, pattern or auto scan.
operating image, press 92 + preset button again.
To return
This feature is operating by preset number
but not included in OSD main menu.

Due to Zoom camera module, OSD Menu provides not every feature.
In this case, “Not
available” is displayed on the monitor.
8
QUICK OPERATING KEYS
DIAGNOSTIC
When Power on, DIAGONOSTIC is operated.
The following messages are displayed on the monitor.
CAMERA ID : 001
BAUD RATE : 2400 BPS
WAITING………
A.
PAN ORIGIN
TEST OK
TILT ORIGIN
TEST OK
TX CONNECTION
TEST OK
CAMERA COMM
TEST OK
Pan Origin Test
Zero point of Pan is founded after Panning test.
B. Tilt Origin Test
Zero point of Tilt is founded after Tilting test.
C.
TX connection Test
Countdown from 60 seconds for TX Connection Test,
During 60 seconds, the camera must receive a signal from any keys of controller or DVR s.
When received the correct signal, OK is displayed after TX CONNECTION TEST.
* If “No Tested” is displayed on the monitor,
- Camera did not receive the any signal.
- Camera did receive the signal but not correct it.
- User should check protocol, baud rate and RS-485 connection.
D.
Camera Comm. Test
Communication test with the camera is automatically checked.
OK should be displayed in these four tests before installation.
If all the above Tests are OK, “NOW EEPROM CHECKING” and “ALL DATA INITIALIZING” is displayed
and the camera is ready to operate.
9
EXIT
SECTOR
ALARM
PATTERN
PRAVACY
TOUR
AUTO SCAN
CAMERA SET
DOME SETUP
MAIN MENU
WB MODE
PIC FLIP
BLC
: OFF
: FAST
: DISABLE
AUTO FLIP
ZOOM SPEED
ALARM
EXIT
SAVE AND EXIT
EXIT
: 01
: 01
: 10
: 200°/S
TOUR STEP
PRESET NO
DWELL TIME
SPEED
EXIT
[PRIVACY CLEAR]
UPGRADED DATE: 06.28,06
COORDINATE:ON/OFF
[PREVIOUS PAGE]
[PREVIOUS PAGE]
[SECTOR CLEAR]
FIRMWARE VER.:2.00
SECTOR ID: OFF ON
10
[LOAD OPTIMIZED DEFAULT
[PREVIOUS PAGE]
[REVIOUS PAGE]
[PATTERN CLEAR]
CAMERA MODULE: SDM100
[PRESET CLEAR]
BAUD RATE: 2400BPS
PRESET ID: OFF/ON
[INITIALIZATION]
[INITIALIZATION]
: XXX.X.XX.X
[TOUR CLEAR]
EXIT
SAVE
[SYSTEM STATUS]
[SYSTEM STATUS]
EXIT
SECTOR END
: SECTOR01□□□
SECTOR START: XXX.X.XX.X
: 01
ALARM ACT
: 100%
SAVE
: 01
SECTOR ID
: OFF
ALARM INPUT
PATTERN01□□□
PROTOCOL : PELCO D,P
OSD DISPLAY
EXIT
SAVE
DATA FILL
PATT TITLE
SECTOR SET
SECTOR NO
: 01
ALARM SET
EXIT
SAVE AND EXIT
: QUICK
: 03
DWELL TIME
ALARM NO.
: 01
PATTERN SET
PATT NO.
: CW
: OFF/ON
SPEED
ENDLESS
CAMERA ID: OFF/ON
ACTION
: 01
EXIT
SAVE
DIRECTION
PAN:XXX.X.XX.X TILT:XXX.X.XX.X
: XXX.X.XX.X
END ANGLE
PRESET ID: PRESET01□□□□□□□□□
AUTO SCAN SET
START ANGLE : XXX.X.XX.X
PRESET SET
PRESET NO: 001
[OSD DISPLY]
NEXT PAGE
SAVE AND EXIT
SAVE
: TOUR01□□□□□□
TOUR TITLE
DISPLAY
: 01
TOUR NO.
PRIVACY NO.
PRIVACY SET
DSS MODE : OFF/ON
TOUR SET
D/N MODE : AUTO
[NEXT PAGE]
: OFF/ON
: OFF/ON
: AWB MODE
: OFF/ON
: OFF/ON
LANGUAGE : ENGLISH
D ZOOM
: 100°/S
MIRROR
: OFF
: OFF/ON
CAMERA SET
FLICKER
MANUAL SPEED
: CAM1□□□□□□□□□□□□
DOME SET
RECOVER
CAMERA ID
OSD MENU SETTING
A. OSD MENU TABLE
OSD MENU SETTING
To enter OSD Menu, press the button 95 + PRESET.
MAIN MENU
DOME SETUP
CAMERA SET
AUTO SCAN
TOUR
PRAVACY
PATTERN
ALARM
SECTOR
EXIT
* Use the joystick “up down” to move the position and “left right” to make selection
B. Dome Setup
In order to enter Dome setup, the joystick move to right direction when cursor on dome setup.
DOME SET
CAMERA ID
: CAM1□□□□□□□□□□□□
RECOVER
: OFF
MANUAL SPEED
: 100°/S
AUTO FLIP
: OFF
ZOOM SPEED
: FAST
ALARM
: DISABLE
LANGUAGE
: ENGLISH
[NEXT PAGE]
SAVE AND EXIT
EXIT
B-1.
DEFAULT SETTING
DOME SET - CAMERA ID
To set camera ID, select up to 16 characters using Joystick to the left or right.
Press ZOOM TELE button to move to the next character from left to right direction and
ZOOM WIDE button to move to the next character from right to left direction
(Space displays when appears)
11
OS D MENU S ETTING
B-2.
DOME SET - RECOVER
This feature allows the dome to work from the last setting before you use the dome manually
(Auto scan, group tour, preset, pattern or sectors), after the set time, even power shut down and it
turns on again.
Recover time can be programmed from 15 second to 99 seconds. The default
setting is OFF.
B-3. DOME SET - MANUAL SPEED
Manual Speed of Pan/Tilt is selectable from 100°/sec up to 150°/sec.
The default setting is
100°/sec
B-4. DOME SET - AUTO FLIP
Auto Flip is available and the default setting is OFF.
OFF. The default setting is OFF.
Move joystick “right or left” to select ON or
This function can be recalled by pushing 67+ preset button.
B-5. DOME SET – ZOOM SPEED
Zoom speeds are selectable FAST or SLOW mode.
Move joystick to the right direction for
selecting FAST or SLOW. The default setting is FAST.
B-6. DOME SET – ALARM
All alarms are available after set as ENABLE Mode.
Move joystick to right or left direction for
selecting ENABLE/DISABLE. The default setting is DISABLE.
This function can be recalled by
pushing 97 + preset button.
B-7. DOME SET - LANGUAGE
Multiple languages are selectable here including English, Italian and Polish.
right or left direction to select language.
Move joystick to the
The default setting is ENGLISH.
B-8. DOME SET – [NEXT PAGE]
DOME SET
SYSTEM LOCK:
: OFF
[PASS WORD]
[OSD DISPLAY]
[SYSTEM STATUS]
[INITIALIZATION]
[PREVIOUS PAGE]
DEFAULT SETTING
B-8-1. DOME SET – [NEXT PAGE] – SYSTEM LOCK
Password protection provides keeping memorized data. It cannot be adjusted by anybody without
password.
In order to enter [PASS WORD] page, system lock status is must set as ON. Move
joystick to right or left direction to select ON. The default setting is OFF.
12
OSD MENU SETTING
B-8-2. DOME SET – [NEXT PAGE] – [PASSWORD]
To enter this page to set a password, move joystick to the right direction. The password must be set
by preset number from 001 to 255 (Default 99)
A. OSD MAIN MENU TABLE (PAGE 14) default setting is BLANK.
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***
Press any number from 001~255 with preset button on password blank and again it on confirm
blank.
Then “CONFIRMED” is displayed on the monitor and the menu will go back to the previous
page automatically.
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***CONFIRMED
ENTER PASSWORD
BY ENTERING PRESET CODE
PASSWORD ***
CONFIRM ***CANCELLED
<CONFIRMED>
<CANCELLED>
If user press wrong preset number between PASSWORD and CONFIRM, “CANCELLED” is
displayed on the monitor and the menu will return to the previous page automatically if user failed 3
times.
* After set a Password, the operator must press memorized password in order to enter OSD MAIN
MENU, or to change the data which is memorized originally.
* The operator must remember the password for the operation and manufacturer provides not
memorized password.
B-8-3. DOME SET – [NEXT PAGE] – [OSD DISPLAY]
OSD ID displayed after set ON in here and it can be hiding if selected OFF.
Move joystick to the
right or left direction in order to select OFF/ON when the cursor is located each item.
13
OSD MENU SETTING
OSD DISPLAY
CAMERA ID
:
PRESET ID
:
SECTOR ID
:
COORDINATE
:
[PREVIOUS PAGE]
OFF
OFF
OFF
ON
DEFAULT SETTING
B-8-4. DOME SET – [NEXT PAGE] – [SYSTEM STATUS]
This page shows the information of this camera.
SYSTEM STATUS
PROTOCOL
:
BAUD RATE
:
FIRMWARE VER. :
UPGRADED DATE :
CAMERA MODULE :
[PREVIOUS PAGE]
PELCO D, P
2400 BPS
1.05
06.12.04
SDM100
DEFAULT SETTING
- Protocol and baud rate are shown according to the dip switch setting
(Refer to page 29, 30 and 31)
- Firmware version and upgraded date will be changed if upgraded.
- Below camera modules can be set as follows.
SDM100 : SAMSUNG 10X ZOOM CAMERA MODULE.
EN300
: OPTICAL 3X MODULE (PAN FOCUS)
B-8-5. DOME SET – [NEXT PAGE] – [INITIALIZATION]
To clear all memorized data for tour, preset, sector, privacy or pattern, move joystick to the right
direction when the cursor is on [INITIALIZATION]
INITIALIZATION
[TOUR CLEAR]
[PRESET CLEAR]
[SECTOR CLEAR]
[PRIVACY CLEAR]
[PATTERN CLEAR]
[LOAD OPTIMIZED DEFAULT]
[PREVIOUS PAGE]
14
OSD MENU SETTING
- To clear memorize any data, move joystick to the right direction when cursor is on each
item.
TOUR CLEAR
TOUR CLEAR
ARE YOU SURE? YES NO
Press FOCUS NEAR button when the cursor is at YES in order to clear memorized data.
Then
flickered each item such as tour, preset, sector and so on is displayed on the monitor about 2~3
seconds.
After this process, the menu is returned to the previous page.
* [PRESET CLEAR], [SECTOR CLEAR], [PRIVACY CLEAR], [PATTERN CLEAR] are same as
[TOUR CLEAR].
LOAD OPTIMIZED DEFAULT
ALL DATA INITIALIZING
ARE YOU SURE? YES NO
- To clear all data and wants returning to factory default, move joystick to the right direction when
cursor is at [LOAD OPTIMIZED DEFAULT] to enter the above page.
- Move joystick to the right or left direction in order to select YES, press FOCUS NEAR button.
- Then “ALL DATA INITIALIZING” is displayed about 5~7 seconds and then the menu are returned
to the previous page automatically.
B-9. DOME SET – [NEXT PAGE] – SAVE AND EXIT
To saving the memorized data and escape this page, move joystick to the right direction
when cursor is at SAVE AND EXIT.
B-10. DOME SET – [NEXT PAGE] – EXIT
In order not to save any data and wants to escape this page, move joystick to the right
direction when cursor is at EXIT
15
OSD MENU SETTING
C. CAMERA SET
CAMERA SET
FLICKER
MIRROR
APERTURE
D ZOOM
WB MODE
PIC FLIP
BLC
D/N MODE
DSS MODE
EXIT
:
:
:
:
:
:
:
:
:
CAMERA SET
OFF
OFF
10
OFF
AWB MODE
OFF
OFF
AUTO
OFF
FLICKER
BLC
EXIT
<10X >
: OFF
: OFF
< 3X >
C-1. CAMERA SET - FLICKERLESS
Flickerless feature is selected between 50Hz and 60Hz.
PAL: 50Hz).
The default setting is OFF (NTSC: 60Hz /
Set flicker mode ON when power source is in discord with frequency. The default
setting is OFF
C-2. CAMERA SET - MIRROR
This feature shows left and right exchanged picture image like mirror.
The default setting is OFF.
C-3. CAMERA SET – APERTURE
Aperture enhances picture details by increasing gain of the caemra and sharpens the edges in the
picture.
The default seeting is 10. (the aperture level is from 01 ~ 15)
C-4. CAMERA SET – D ZOOM
Move joystick to the right direction in order to set as ON, if Digital Zoom is necessary at install field.
The default setting is OFF.
C-5. CAMERA SET – WB MODE
White balance functions have 4 modes according to the condition of exterior lighting. The default
setting is AWB and it may change the mode option accoding to the lighting conditions as below.

AWB Mode – 3,200°K to 6, 000°K

Indoor – up to 3,200°K

Outdoor – up to 5,800°K

ATW Mode -
(Default)
2,000°K to 10, 000°K
16
OSD MENU SETTING
C-6. CAMERA SET – PIC FLIP
Picture flip feature provides the top and down exchanged picture image horizontally. Move joystick to
the right or left direction to select OFF/ON.
The default setting is OFF.
C-7. CAMERA SET – BLC (Back Light Compensation)
The default setting is OFF and BLC modes can be OFF/ON.
OFF – Backlight compensation is not activated.
ON – Back light compensation is activated.
This function can be recalled by pushing 93 + preset button.
C-8. CAMERA SET – D/N MODE
ICR filter is changeable according to the lighting, AUTO – NIGHT MODE – DAY MODE.
The default setting is AUTO MODE. This function can be recalled by pushing 94 + preset button.
C-9. CAMERA SET – DSS MODE (DIGITAL SLOW SHUTTER)
If DSS turns on, digital slow shutter is working. Per second, the electronic shutter will remain open
to receive some more lighting.
The default setting is OFF.
C-10. CAMERA SET – EXIT
To escape this page, move joystick to the right direction.
17
OSD MENU SETTING
D. PRESET SET
To enter PRESET SET, move joystick to the right direction.
PRESET SET
PRESET NO :001
PRESET ID :PRESET001------PAN :XXX.XX TILT : XXX.XX
SAVE
EXIT
D-1.
DEFAULT SETTING
PRESET – PRESET NO.
Up to 165 numbers of preset positions are available.
Move joystick to the right or left direction to
select preset no.
D-2. PRESET – PRESET ID
To set preset ID, select up to 16 characters using Joystick to the left or right.
Press ZOOM TELE button moves to the next character from the left to the right direction and
ZOOM WIDE button moves to the next character from the right to left direction
(Space displays when appears)
D-3. PRESET – PAN: XXX.X TILT: XX.X
Press FOCUS FAR button in order to set preset position then, use the joystick to the position
where memorized preset no. is needed. Then press FOCUS FAR button again after setting a
preset location.
D-4. PRESET – SAVE
Move joystick to the right direction when the cursor is at SAVE and then the cursor will be located
on Preset ID for the continuous preset No. setting.
D-5. PRESET – EXIT
To escape this page, move joystick to the right direction.
18
OSD MENU SETTING
E. AUTO SCAN SET
* 66 + preset button is working as AUTO SCAN after setting.
AUTO SCAN SET
START ANGLE
END ANGLE
DIRECTION
ENDLES
SPEED
DWELL TIME
SAVE AND EXIT
EXIT
:
:
:
:
:
:
XXX.X.XX.X
XXX.X.XX.X
CW
OFF
10°/S
03
DEFAULT SETTING
E-1. AUTO SCAN – START ANGLE
To set start angle, press FOCUS FAR button then move joystick to the starting angle which is needed
memorized.
To press FOCUS FAR button again is to escape.
E-2. AUTO SCAN – END ANGLE
To set end angle, press FOCUS FAR button then move joystick to the starting angle which is
needed memorized.
To press FOCUS FAR button again is to escape.
E-3. AUTO SCAN – DIRECTION
Auto Scan directions are available with two direction as CW or CCW by joystick to the right or left
direction
CW: Clock wise direction (Default)
CCW: Count Clock Wise Direction.
E-4. AUTO SCAN – ENDLESS
Auto Scan can use endless rotation, move joystick to the right direction in order to select ON.
Otherwise, the default setting is OFF.
E-5. AUTO SCAN – SPEED
User can use auto scan speed from 05°/S up to 35°/S and the default setting is 10°/S.
E-6. AUTO SCAN – DWELL TIME
To select dwell time, move joystick to the left or right direction in order to adjust dwell time. Possible to
set from 01 second to 30 seconds and the default setting is 03 seconds.
E-7. AUTO SCAN – SAVE AND EXIT
To saving the memorized data and escape this page, move joystick to the right direction
when cursor is at SAVE AND EXIT.
E-8. AUTO SCAN – EXIT
To escape this page, move joystick to the right direction.
19
OSD MENU SETTING
F. TOUR SET
8 Programmable tours can be set and each tour is available to set up to 64 preset steps.
After setting
the data to the each tour group, 71~78 + preset buttons are working as group tour # 1~8
TOUR SET
TOUR NO
TOUR TITLE
TOUR STEP
PRESET NO.
DWELL TIME
SPEED
SAVE
EXIT
:
:
:
:
:
:
01
TOUR01□□□□□□□□□□
01
01
03
200°/S
DEFAULT SETTING
F-1. TOUR SET – TOUR NO.
Max.
8 group tour no. set by the joystick are available.
F-2. TOUR SET – TOUR TITLE
To set tour title, select up to 16 characters using Joystick to left or right.
Press ZOOM TELE button to move the next character from the left to the right direction and ZOOM
WIDE button to move the next character from the right to left direction (Space displays when 
appears) Tour title is not displayed on the monitor, but only for the reference of user.
F-3. TOUR SET – TOUR STEP
Each tour group consists of up to 60 preset steps with different dwell time and speed. It is possible
to match any preset # for each tour step.
F-4. TOUR SET – PRESET NO.
The decided tour step #1 ~64, it is possible to select any preset no. up to 64.
The default setting
is BLK
F-5. TOUR SET – DWELL TIME
Dwell time provides up to 99 seconds from 01 second.
The default setting is 03 seconds.
F-6. TOUR SET – SPEED
Each tour step can be set with different tour speed up to 200°/S and it is selectable from 10°/S.
Move joystick to the right or left direction to select tour speed. The default setting is 200°/S.
F-7. TOUR SET – SAVE
To save the memorized data and escape this page, move joystick to the right direction when
cursor is at SAVE
F-8. TOUR SET – EXIT
To escape this page, move joystick to the right direction
20
OSD MENU SETTING
G. PRIVACY SET
4 Privacy masking zones are available to block out areas of security.
PRIVACY SET
PRIVACY NO
DISPLAY
ACTION
SAVE
EXIT
: 01
: OFF
: MOVE
DEFAULT SETTING
G-1. PRIVACY SET – PRIVACY NO.
It provides up to 4 privacy masking zones
G-2. PRIVACY SET – DISPLAY.
Move joystick to the right or left direction to set ON in order to show the selectable block in the
center of the monitor.
This block appears as a translucent square with blue color after set ON.
The default setting is OFF.
G-3. PRIVACY SET – ACTION (MOVE / ADJUST)
To set the blocking area, press FOCUS FAR button when the MOVE MODE is appeared.
use the joystick to the user defined area in order to set blocking area.
Then
Then press FOCUS FAR
button again to escape from MOVE MODE.
To adjust size of blocking area, move joystick to the right or left direction when the cursor is on
ACTION. After changed to ADJUST MODE, press FOCUS FAR button in order to adjust the size of
blocking area. The size of blocking area can be adjustable by using joystick up down or left right.
After adjusting size of blocking area, press FOCUS FAR button to escape ADJUST mode.

ADJUST: You can change the masking size by using joystick to the left or right direction

MOVE: You can move the masking area by using joystick to the left or right direction (Default)
G-4. PRIVACY SET – SAVE
After setting the privacy masking zone, to save the data, move joystick to the right direction when
the cursor is on SAVE. After saving the data, the cursor moves to PRIVACY NO.2 automatically to
prepare the next privacy masking zone.
G-5. PRIVACY SET –EXIT
To escape this page, move joystick to the right direction
OSD MENU SETTING
H. PATTERN SET
21
8 programmable patterns are available with 16 characters of title.
After setting the data to each pattern # 1~8, 81~88+ preset buttons are working as Pattern # 1~8.
PATTERN SET
PATT NO
: 01
PATT TITLE: PATTERN01□□□□□□□
DATA FILL : 0%
SAVE
EXIT
DEFAULT SETTING
H-1. PATTERN SET –PATT NO.
Up to 8 programmable user-defined patterns set by the joystick are available.
H-2. PATTERN SET –PATT TITLE
To set PATTERN TITLE, select up to 16 characters using Joystick to the left or right.
Press ZOOM TELE button moves to the next character from the left to the right direction and
ZOOM WIDE button moves to the next character from the right to left direction (Space displays
when appears) Pattern title is not displayed on the monitor, but only for the reference of user.
H-3. PATTERN SET –DATA FILL
To fill the programming data, press FOCUS FAR button in order to start the data fill up. Filling data
is programmed according to the joystick movement.
Press FOCUS FAR button again in order to
escape.
H-4. PATTERN SET –SAVE
To saving the filling data, move joystick to the right direction when the cursor is on SAVE. Then the
cursor moves to the PATT NO.02 in order to prepare next pattern no.
H-5. PATTERN SET –EXIT
To escape this page, move joystick to the right direction
OSD MENU SETTING
I. ALARM SET
22
4 Alarm inputs are available and each alarm is activating to presets, group tours or patterns.
ALARM SET
ALARM NO
: 01
ALARM INPUT: OFF
ALARM ACT : 001
SAVE
EXIT
DEFAULT SETTING
I-1. ALARM SET – ALARM NO.
Up to 4 alarms are selectable by using joystick to the right direction when cursor is on ALARM NO.
I-2. ALARM SET – ALARM INPUT
Input alarm ways provide two different ways as NC (Normal Close) or NO (Normal Open)
The default setting is OFF
I-3. ALARM SET – ALARM ACT
Alarm activates various surveillance modes with Preset number up to 165, Group tour up
to 8, Pattern up to 8.
Move joystick to the right or left direction to select any preset
number, group tour no. or pattern no.
I-4. ALARM SET – SAVE
After setting the alarm input ways and activation, to save the data, move joystick to the right
direction when the cursor is on SAVE. After saving the data, the cursor moves to Alarm NO.2
automatically to prepare the next alarm.
I-5. ALARM SET –EXIT
To escape this page, move joystick to the right direction
* Before activating Alarm, user must set ALARM ENABLE at DOME SET – ALARM – ENABLE
(Refer to page 15)
23
OSD MENU SETTING
J. SECTOR SET
Up to 8 programmable sectors are available with 16 characters.
This feature is useful to memory the certain location such as parking zone or so on.
When camera goes through this area, it shows the letter you memorized.
SECTOR SET
SECTOR
SECTOR
SECTOR
SECTOR
SAVE
EXIT
Start Position
NO
: 01
ID: SECTOR01□□□□□□□□
START: XXX.X.XX.X
END
: XXX.X.XX.X
End Position
DEFAULT SETTING
J-1. SECTOR SET – SECTOR NO.
Up to 8 programmable sectors set by the joystick are available.
J-2. SECTOR SET – SECTOR ID
To set SECTOR ID, select up to 16 characters by using Joystick to the left or right.
Press ZOOM TELE button to move to the next character from the left to the right direction and
ZOOM WIDE button to move to the next character from the right to left direction (Space displays
when appears)
J-3. SECTOR SET – SECTOR START
To set SECTOR START angle, press FOCUS FAR button then move joystick to the left or right
direction to set the position.
To press FOCUS FAR button again is to escape.
J-4. SECTOR SET – SECTOR END
To set SECTOR END angle, press FOCUS FAR button then move joystick to the left or right
direction to set the position. To press FOCUS FAR button again is to escape.
J-5. SECTOR SET – SAVE
After setting the SECTOR position, to save the data, move joystick to the right direction when the
cursor is on SAVE. After saving the data, the cursor moves to SECTOR NO.2 automatically to
prepare the next SECTOR.
J-6. SECTOR SET –EXIT
To escape this page, move joystick to the right direction
K. EXIT
To escape OSD Main Menu, move joystick to the right or left direction then this camera is
ready to operate.
24
DIP SWITCH SETTING
A-1. DIP SW SETTING
st
th
Mini Speed Dome camera provides up to 63 cameras ID and it’s an adjustable ID with 1 ~6 of Dip
switch.
Open the camera case to set ID using DIP SW1.
* Factory default: Camera ID = 1, PELCO-D Baud Rate: 2400bps
Termination
Baud rate
Protocol
ID Set
A-2. ID SETTING (1-ON, 0-OFF) (110)
DIP SW
100000XXXX
010000XXXX
110000XXXX
001000XXXX
101000XXXX
011000XXXX
111000XXXX
000100XXXX
100100XXXX
010100XXXX
110100XXXX
001100XXXX
101100XXXX
011100XXXX
111100XXXX
000010XXXX
100010XXXX
010010XXXX
110010XXXX
001010XXXX
101010XXXX
011010XXXX
ID VALUE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
DIP SW
111010XXXX
000110XXXX
100110XXXX
010110XXXX
110110XXXX
001110XXXX
101110XXXX
011110XXXX
111110XXXX
000001XXXX
100001XXXX
010001XXXX
110001XXXX
001001XXXX
101001XXXX
011001XXXX
111001XXXX
000101XXXX
100101XXXX
010101XXXX
110101XXXX
001101XXXX
ID VALUE
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
DIP SW
101101XXXX
011101XXXX
111101XXXX
100011XXXX
100011XXXX
010011XXXX
110011XXXX
001011XXXX
101011XXXX
011011XXXX
111011XXXX
000111XXXX
100111XXXX
010111XXXX
110111XXXX
001111XXXX
101111XXXX
011111XXXX
111111XXXX
ID VALUE
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
44
25
DIP SWITCH SETTING
A-3. PROTOCOL
th
th
7 ~8 dip switches are used for Protocol Setting.
Factory Default: Pelco-D or Pelco-P (Auto detection)
DIP SW1- 7
DIP SW1- 8
OFF
OFF
Pelco-D or Pelco-P
A-4. BAUD RATE SETTING
th
The 9 Dip Switch is used for BAUD RATE setting.
DIP SW can be changeable to 2400bps, 9600bps.
Factory Default: 2400bps.
DIP SW1 9th
BAUD RATE
OFF
2400
ON
9600
.
A-5. 485 TERMINATIONS
th
10 Dip Switch is used for 100Ω termination.
th
Set on 10 Dip Switch only for the last looped camera from the controller.
th
Even in case of only one camera, set on 10 Dip Switch of the cameras.
26
TROUBLESHOOTING
If you have trouble in operating in your camera, refer to the following.
PROBLEM
SOLUTION
No operating
Check if the power supply is DC12V.
Check if RS-485 communication cable is connected correctly.
Check camera ID setting.
Check the termination.
No picture
Check if all the cables are connected correctly.
Check if the monitor is adjusted correctly.
Check if video signal line is cut.
Dark screen
Adjust the monitor status.
Abnormal camera
Operation status
Check if voltage level is out of the specification.
Check the termination.
Screen not clear
Check if there is dust on the lens.
Adjust the monitor status.
If excessive light is seen on a screen, change the camera
angle or location.
Adjust the lens focus again.
27
SPECIFICATIONS
MODEL
PAN /TILT
10X A/F CAMERA MODULE
Pan Rotation Angle
Manual
Pan Speed
Preset
Tilt Rotation Angle
Manual
Tilt Speed
Preset
System Accuracy
Presets
Group Tour
FUNCTIONS
POWER
OTHERS
Auto scan
Pattern
Privacy Zone
Sector
Password Protection
Alarm Input
Alarm Actions
Auto Flip
OSD Menu
Communication
Protocol
Consumption (12V DC)
Consumption (24V AC)
Power Supply(12V DC)
Power Supply(24V AC)
Construction
Dimensions
Weight
Motor Type
Micro Steps
Storage Temperature
Operating Temperature
Certifications
Image Sensor
Total
NTSC
Image
PAL
Pixels
Number Of NTSC
Effective
PAL
Pixels
Horizontal resolution
Lens
CAMERA
MODULE
Optical
Digital
Day & Night (ICR)
Min. Shooting Distance
Digital Slow Shutter
Normal
mode
Min.
illumination Night
mode
Luminance S/N Ratio
Video Output
BLC
NTSC
Flickerless
PAL
WHITE BALANCE
3X PAN FOCUS MODULE
360˚ Endless
100˚ ~ 150˚/sec
Max 200˚ /sec
0˚ ~ 90˚
100˚ ~ 150˚/sec
Max 200˚ /sec
0.02˚
165 positions with a 16-character label available for each position
with different speed steps
Max. 8 Programmable group tours (each one consisting of up to 60 preset steps
with different steps)
Programmable Auto scan
8 Programmable Patterns (total 480 seconds)
4 privacy zones
8 selectable Sectors with 16 characters
Yes
4 alarms OFF/NC/NO (with various programmable states)
Activate preset, Group scanning or Patterns
ON / OFF
Multiple Languages on screen
RS-485
Pelco D/P
9W Max (Heater Type 15W)
18W Max (Heater Type 30W)
DC12V 750mA (Heater Type DC12V 1.2W)
AC 24V 650mA (Heater Type AC24V 1.3W)
die-casting , Anti-vandal dome cover
158.8φ (D) * 163.0mm(H)
1.5 kg
Stepper Motor
1/4 Step
-10℃ ~ 60℃
0℃ ~ 50℃
CE, FCC
1/4" Sony Super HAD CCD
811(H) * 508(V) 410K
795(H) * 596(V) 470K
768(H) * 494(V) 380K
752(H) * 582(V) 440K
More Than 500TV Lines
More Than 520TV Lines
10x Optical Zoom
(F=3.8 to 38mm)
3x Optical Zoom
(F=1.9~2.8, f=4.1~7.3mm)
10x (100x with optical)
Auto/ Day/ Night
0.35m(Wide)/0.8m(Tele)
2/4/8/16/24/32/64/128/ OFF
0.32m(Wide)/1.5m(Tele)
-
0.7Lux (50IRE)
1.0Lux (50IRE)
0.02Lux (ICR On)
More than 50dB
VBS:1.0Vp-p/75 Ohm
ON / OFF
ON / OFF (1/100)
ON / OFF (1/120)
AWB/ATW/INDOOR/ OUTDOOR
AWB only
28
DIMENSIONS
29
General Information
Limited Warranty
At Discount Security Cameras (DSC) we take pride in offering only the highest quality reliable products.
In the rare event that a defect does occur we offer the following warranty:
All products are warranted by Discount Security Cameras for 1 year from date of purchase, except for
Clearance items, which are warranted for 30 days. If a product is defective we will repair or replace it.
The customer is responsible for the shipping to send the product to us. We will cover the freight to return
the product back to the customer.
After 1 year we will continue to service your products for the standard labor rate (currently $45 per hourminimum 2 hours) plus parts or phone technical support for $50.00/hour.
The following situations void the product warranty: 1. Opening the housing of any camera with a fixed
lens; 2. Cutting the connectors off any equipment; 3. Adding 3rd party software to a DVR without prior
approval from our technical support department; 4. Damage caused by nature such as water flooding,
winds, lightning and other similar events; the fault of the installer or customer (for example dropping or
breaking the product, improper voltage, or improper installation) and failing to follow safety tips as
previously mentioned above.
RMA: All returns and warranty services require a valid Returned Merchandise Authorization Number
(RMA#) issued by Discount Security Cameras. Merchandise will not be honored and will be returned to
customer without RMA#. You must provide the Optiview Serial number of the unit when calling for
technical service or Return Material Authorization (RMA) number.
All returns and warranty services require a valid Returned Merchandise Authorization Number (RMA#)
issued by Optiview. RMA numbers are only valid for 14 days from date of issuance.
Technical Support
You will need to contact the vendor, where you originally purchase this Mini PTZ Camera, if you need
technical support. The Serial number of the Camera is located at the bottom of the main internal dome
camera which can be access by opening up the clear acrylic dome cover. You will need to have this ready
prior to calling our Optiview Technical support group to avoid delay or denial of support for this product.
You may also use your Order number or Invoice number as your reference prior to calling us for technical
support. You can contact us at 904-855-1121 or email us at [email protected]
30
Return Policy
Merchandise may be returned for a refund or exchange for 15 days from day of receipt as long as the
equipment is still in "as new" condition. A 15% restocking fee may apply. Shipping costs are not
refundable (unless the product is defective - see warrantee below).
"As New" means that all items must be undamaged and in their original cartons and packaging along with
all accessories, documentation, and parts. No wires or pigtails can be cut. The product exterior must be
intact and unmarked. The original carton must be in another "shipping" box. No postmarks or labels shall
be on the original box. Cable must be unopened (or still on reel).
A Return Merchandise Authorization (RMA) number must be obtained from Optiview prior to the return
of any merchandise. An RMA number is only valid for 14 days (returned products must be received
within 14 days from issuance of the RMA number).
Return and Warranty information may be updated or changed without prior notice.
For complete and updated information on warranty and return policy, go to
http://www.optiviewpro.com/return_warranty.htm
Camera Serial #: __________
Invoice/Order#____________
Date of Purchase: __________
31
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement