Multi Variable Air Conditioners Duct Type Indoor Unit Owner’s Manual Please read this manual carefully before operating USER NOTICES ☆ When the unit is operating, the total capacity of the indoor units should be no more than the capacity of outdoor unit. Otherwise, it can cause the shortage of cooling capacity (heating capacity) of each indoor unit. ☆ The power supply of the indoor unit must be the unified power supply. The indoor unit cannot have the individual power switch, and the entire indoor unit can only be controlled by one main power control. Disconnect the main power of all the indoor units before cleaning. ☆ In order to start the unit successfully, the general power supply switch of the air-conditioning units should be turned to the “ON” position for 8 hours before running. ☆ After each of indoor units received the stop running signal, the fan motor of the indoor unit will use the surplus cool or surplus heat of the heat exchanger go on running for 20-70 seconds, this is the preparation for the next time use and this is the normal phenomenon. ☆ When the selected mode of the indoor unit conflict with the mode of outdoor unit, after 5 seconds, the wired remote control will display the operation conflict, the indoor unit will stop running, then to unify the running modes of the indoor unit and outdoor unit, the unit will get right. There is no conflict in the COOL mode and DRY mode, the FAN mode will not conflict with any other modes. ☆ The appliance shall not be installed in the laundry ☆ An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring 1 Safety Precautions Before using the appliance, read this manual thoroughly and operate under its direction. “WARNING” and “ATTENTION” have the follow ing meanings in these instructions: 1. 2. WARNNING! :This mark indicates procedures, which if improperly performed, might lead to the death or serious injury of the users. ATTENTION! :This mark indicates procedures, which if improperly performed, might possibly result in personal injury to the user, or damage to property. WARNNING ! ● When install the unit, please relegate to the special arrangement maintenance center. If improper performed, it can cause the water leakage, electric shock and fire etc. accidents. ● Please install the unit to a steady and stable place. If the intension is inadequate, the unit will drop off and will lead to the personal injury and death. ● In order to make sure the right water drainage, the installation of drainage pipe should be according to the installation methods of this manual, and also adopt the heat retaining measure to prevent the water condensing. If installed improperly, it will cause water leakage and might moisten the furniture. ● Do not use or store the combustible and detonatable materials near the air conditioner. ● When malfunction happed (there is the burning smell etc.), please power off the general power supply of the units. ● Keep the well ventilation in order to avoid the oxygen lack. ● Do not insert hands or other objects into the inlet or outlet grille. ● Due to the long time use, please check the mounting frame if broken or not. ● Do not refit the unit. When need to maintenance or remove the unit, please contact with the local dealer or the professional. ATTENTION!: ● Ensure the power supply correspond to the nameplate and check the security of the power source before installation. ● Make sure that the wires, pipes and drain hose are properly connected before operation to avoid a fire or electric shock. ● The general power supply must be reliably earthed! To ensure the units are earthed availably, to avoid the electric shock. The earth wire can’t be connected to the gas pipe, water pipe, wires of the lightning rod and telephone. ● Once the units start, need at least more than 5 minutes running then it could be turned off. ● Don’t let children operate the units. ● Do not operate the units with wet hands. ● When cleaning the air conditioner or changing filters, please turn off the general power supply of the units firstly. ● Switch off power source when the units will not be operated for a long period. ● Do not expose the units to the water place or the damp place or the corrosion environment. ● After installation, when electrified the electric leakage should be tested. 2 The selection of installation place and notice of the air conditioner unit ● The selection of the installation place of the air conditioner unit The installation must accord with the national and local safe criterion. Since the quality of installation would affect the operation directly, user should contact the seller and have the conditioner installed and tested by the professional install personnel according to the install instruction instead of install by himself/herself. Only connect the power after all the installation works are finished. ● The selection of the installation place of the indoor unit ☆ Prevent direct sun burn. ☆ Make sure that the top steeve, ceiling, and the structure of the construction etc. is strong enough to bear the weight of the unit. ☆ The drainage pipe is easy to drain. ☆ The air flow is not blocked at the outlet and intake vents. ☆ The connecting pipe indoor and outdoor can by lead to outside conveniently. ☆ The unit cannot be installed in the place where stored the flammability, easy exploded thing or the place where would have leakage of flammability and exploded gas. ☆ The unit cannot be installed in the place where has the corrupt gas and serious dust, saline fog, lampblack and huge humidity. Note! The air conditioner unit installed in the following place may have malfunction, if the malfunction cannot prevent, please contact the Registered Office Of MIRC ELECTRONICS LTD., MUMAI. ①the place with greasy all around; ②the seashore place with salinity and alkali; ③the place with vulcanized gas( such as vulcanized hot spring); ④the place with high frequency equipment ( such as wireless equipment, electric welding machine and medical treatment equipment);⑤the place with special environment. ● The electric cord disposal ☆ The cord disposal should be installed according to the National Principal. ☆ The power must use the rated voltage and the electric circuit specific for air conditioner unit. ☆ Please don’t pull the power cord vigorously. ☆ All the electric equipment should be installed by the professional personnel according to the local law, regulation and this instruction. ☆ The power cord diameter should be big enough, the destroyed power cord and connecting cord should be replaced by the specific cord. 3 The selection of installation place and notice of the air conditioner unit ☆ The earthing should reliably connected with the specific earthing equipment in the architecture, and this should be done by the professional personnel. There must be creepage protection switch and air switch with enough capacity in the rated circuit (reference the following form). The air switch should maintain the functions of magnetic de-buckle and heat de-buckle to assure the protection when circuit-short and overload happen. ● ☆ Earthing requirement The air conditioner is class I appliance, so please do take the reliable measurement to earthing. ☆ The yellow and green cord in the air conditioner unit is earthing cord which cannot be used for other purpose, and cut off, as well as fixed up with screw. Otherwise, it would lead electric shock. ☆ The reliable earthing terminal must be offered by the user power. And please don’t connect the earthing cord to the following place: ①Tap water pipe; ② Coal gas pipe; ③ Ejection pipe; ④ The place that is consider to be not reliable by the professional personnel. ● The attachment used for installation Every attachment used for installation of the indoor and outdoor unit please refer to the packing list in every individual package carton. 4 ● Install of the ducted type indoor unit Shape dimension diagram of indoor unit The following figure is applicable to the indoor units of OV(L)-R22P/NaB-K 、OV(L)-R28P/NaB-K 、 OV(L)-R36P/NaB-K 、OV(L)-R22PS/NaB-K 、OV(L)-R28PS/NaB-K 、 OV (L)-R36PS/NaB-K 、 、 、 、 、OV(L)-R28PS/HB-K、 ( L ) -R22P/HB-K OV ( L ) -R28P/HB-K OV ( L ) -R36P/HB-K OV (L) -R22PS/HB-K OV 、 、 、 OV (L)-R36PS/HB-K OV (L)-R22P/NaB-D OV (L)-R28P/NaB-D OV (L)-R36P/NaB-D。 Fig.1 The following figure is applicable to the indoor units of OV(L)-R45P/NaB-K、OV(L)-R56P/NaB-K、OV(L)-R71P/NaB-K、 OV (L)-R90P/NaB-K、OV (L)-R112P/NaB-K 、OV (L)-R140P/NaB-K、OV (L)-R45PS/NaB-K、OV(L)-R56PS/NaB-K 、 (L)-R45P/HB-K、 OV (L)-R71PS/NaB-K、OV (L)-R90PS/NaB-K、OV(L)-R112PS/NaB-K、OV (L)-R140PS/NaB-K、OV OV (L)-R56P/HB-K 、OV (L)-R71P/HB-K、OV(L)-R90P/HB-K、OV(L)-R112P/HB-K、OV (L)-R140P/HB-K、 OV(L)-R45PS/HB-K、OV (L)-R56PS/HB-K、OV (L)-R71PS/HB-K、OV (L)-R90PS/HB-K、OV (L)-R112PS/HB-K、 OV(L)-R140PS/HB-K、OV (L)-R56P/NaB-D、OV (L)-R71P/NaB-D、OV (L)-R90P/NaB-D、OV (L)-R112P/NaB-D 、 OV(L)-R140P/NaB-D。 5 Install of the ducted type indoor unit Fig.2 1、Look into from air outlet vent, the wiring is in the left of the unit. 2、The method of wind circle can be selected to bottom back wind or rear back wing according to the installation circumstance of the reality. MODEL NO. OV(L)-R45P/NaB-K OV(L)-R45PS/NaB-K OV(L)-R45P/HB-K OV(L)-R45PS/HB-K OV(L)-R56P/NaB-K 、 OV(L)-R71P/NaB-K OV(L)-R56PS/NaB-K 、 OV(L)-R71PS/NaB-K OV(L)-R56P/HB-K 、 OV(L)-R71P/HB-K OV(L)-R56PS/HB-K 、 OV(L)-R71PS/HB-K OV(L)-R56P/NaB-D OV(L)-R90P/NaB-K 、 OV(L)-R112P/NaB-K 、 OV(L)-R90PS/NaB-K 、 OV(L)-R112PS/NaB-K 、 OV(L)-R90P/HB-K 、 OV(L)-R112P/HB-K 、 OV(L)-R90PS/HB-K 、 OV(L)-R112PS/HB-K 、 OV(L)-R90P/NaB-D OV(L)-R140P/NaB-K 、 OV(L)-R140PS/NaB-K OV(L)-R140P/HB-K 、 OV(L)-R140PS/HB-K OV(L)-R140P/NaB-D ● A B C D E F G H I J 932 430 738 892 980 721 738 125 203 266 1114 420 918 1074 1159 736 1010 207 207 300 1382 420 1155 1340 1425 736 1280 207 250 300 1382 420 1155 1340 1425 736 1280 207 250 300 Schematic diagram of installation spaces Nut with washer Nut spring pad Fig.3 6 Install of ducted type indoor unit ● Schematic diagram of installation spaces 1. Ensure that the latches at top are firm enough to stand the weight of unit. 2. Convenience to drain by the drain hose. 3. There is no obstruct around intake and outlet vent keep well ventilation. 4. Ensure the install distance of the indoor unit as shown in fig.3, ensure the necessary space for care and maintenance. 5. Far from space heater, leakage of combustible gas and place with fog. 6. This unit is model cassette type (hide installation type is hided in ceiling), as shown in fig.6. 7. Indoor unit, outdoor unit, power cord, and connection pipe should have at least 1m’s distance with TV set, radio, to prevent the appearance of disturb picture and noise happened on the above mentioned home appliance. (If the electric wave were strong, even though 1m had maintained, noise would still happened. ● Install the indoor unit 1. Insert the M10 inflate bolt to the hole then nail the iron nails into the bolts. The distance between holes is shown in fig.1. The install of inflate bolt is shown in fig.4. Fig.5 Fig.4 ≤48 2. Install the hook on the unit, as shown in fig.5. 3. Install the indoor unit to the ceiling as shown in fig.6. Fig.6 Note: ☆ To open an opening on the ceiling, probably reinforce would to be done to keep the ceiling smooth and to prevent vibration. Please consult user or builder for detail. 7 Install of ducted type indoor unit ☆ If the ceiling if not strong enough, an angle iron stand can be made and has the unit fixed on the stand. ● Water lever test for indoor unit The water lever test must be tested after installing the indoor unit to make the front, back, left and right or the unit are horizontal, as shown below. Horizontal tester ● Install of wind supply pipe Ceiling hoisting Back wind Wind supply Back wind Fig.7 Sketch of install ducted type unit No. 1 Name Hoisting 2 Back wind pipe 3 Ducted type indoor unit 4 Back wind vent 5 Wind supply bent 6 Wind outlet Note:Fig.7 only shows the install of rear back wind vent, button back wind vent can also been installed according to the actual install need. The method of install is similar to the rear back wind vent’s. The wind supply pipe, which is rectangle or circle and connect with the wind vent of the indoor unit, should at least keep one open. The circle wind pipe type should adopt circle preservation pipe to transmit cool (heat) wind to room. The circle wind pipe should add a transitionary pipe, which size should match the size of wind supply vent of the unit. After connecting the transitionary pipe, install the circle wind outlet vent connection pipe, whose longest length to every individual wind outlet vent should not over 10m. Ducted type indoor unit model 70 can share 3 trainsitional pipe, while model 100,120 can share 4. The transitional pipe, whose straight length is 200, and circle wind outlet connection pipe, whose diameter is 200, produced by our company, can be ordered separately as standard fittings. Model 50 and the model below it do not share circle wind vent. The following is the diagram for install circle wind pipe. 8 Install of ducted type indoor unit Note: 1、The longest length of wind pipe means the general length of the wing supply pipe to the farthest wind supply vent plus the general length of back wind pipe to the relative farthest back wind vent. 2、To the unit with auxiliary heater, if the circle wind pipe is need to connected, the straight length of trainsitional wind pipe should not shorter than 200mm. 1 2 3 4 5 6 7 Number 1 2 3 4 5 6 7 Name Screw Back wind pipe Ducted type indoor unit Back wind vent Trainsitional wind pipe Wind supply pipe Wind outlet pipe ● Install proceed of circle wind pipe 1. Preinstall the circle wing outlet vent on the transitional pipe and fixed it by screw; 2. Sheath the transitional wind pipe on the wind outlet vent and connect by rivet; 3. Sheath the wind outlet pipe on circle wind outlet vent and prick it tightly by strap, so the connection with the unit finished. Other proceeds are omitted. ● Type and dimension of the back wind, wind supply vent A 40 B Product model OV(L)-R22,28,36P(S)/HB-K OV(L)-R22,28,36P(S)/NaB-K OV(L)-R22,28,36P(S)/NaB-D OV(L)-R45P(S)/HB-K OV(L)-R45P(S)/NaB-K OV(L)-R56,71P(S)/HB-K OV(L)-R56,71P(S)/NaB-K OV(L)-R56,71P(S)/NaB-D O V ( L ) - R 9 0 , 11 2 , 1 4 0 P ( S ) / N a B - K O V ( L ) - R 9 0 , 11 2 , 1 4 0 P ( S ) / N a B - K O V ( L ) - R 9 0 , 11 2 , 1 4 0 P ( S ) / N a B - D 9 Dimention of wind supply port A B Dimention of back wind port A B 125 635 203 738 125 738 203 738 207 918 250 1010 207 11 5 5 250 1280 ● Install of ducted type indoor unit Install the back wind pipe 1. Rear back wind type is adopted for the unit when the unit leaves the factory, and the back wind cover is installed at the bottom as shown below. 2. When button back wind vent is needed to adopt, change the position of rectangle flange and back wind cover. Ractangle flange Rear back wind Button back wind Back wind cover 3. Connect the back wind pipe on the back wind vent of the indoor unit by rivet, and connect the other terminal to back wind vent. In order to adjust the weight conveniently, pucker a canvas wind pipe, and strengthen it with 8# iron thread. ☆ Install type can be selected according to the overall plans and all factors into the conditions of architect and maintenance, as shown in fig.8a, and fig.8b. 5 4 5 Wind supply 3 Wind supply 2 4 1 Back wind 6 1 Back wind Install the back wind pipe(b) Install the back wind pipe (a) Fig.8 Install the back wind pipe No. Name No. Name 1 Back wind vent (with filter) 4 Indoor unit 2 Canvas wind pipe 5 Wind supply pipe 3 Back wind pipe 6 Test grill 10 Install of ducted type indoor unit ● Install new wind pipe 1. When new wind pipe is need to be connected, cut the new wind baffle as shown in fig.9. Plug up the gap of new wind baffle by sponge if new wind pipe is not used. 2. Install the circle flange so that the new wind pipe can be connected as fig.10. Cut off Cut off New wind baffle Circle wind pipe Fig.9 Fig.10 3. Well sealed and heat preservation should be done for both wind pipe and circle flange pipe. 4. New wind should be the air after filtrate treatment. Attention: ● There should be thermal insulation layers around the air delivery and air return ducts as well as on the new air ducts to protect against heat losses and condensation. Adhere the plastic nails onto the ducts, and then attach a layer of insulation cloth with the tinfoil onto the ducts. Fix the plastic nail and then seal tightly the joints by way of tinfoil tapes. Some other materials with good thermal insulation properties can also be used. ● The air delivery and air return ducts should be fixed to the prefabricated ceiling boards with iron stands. The joints of the air ducts should be sealed tightly to prevent from air leakage. ● The designing and operation of the air ducts should comply with the related state standards and procedures for engineering. ● It is recommended to leave at least a space of 150mm between the edge of the air return duct and the wall, and a filter screen should be placed at the air return opening. ● Muffling and vibration reduction should be taken into consideration during the designing and operation of the air ducts. In addition, the noise source should be kept away from the crowds. It is absolutely not allowed to design the placement of the air return opening right above the head of the users (in the offices, lounges or other public sites). ● Installation of Condensed Water Pipes ☆ The condensed water pipes should be kept at 5—10 degrees of gradient to facilitate discharge of the condensed water. Thermal insulation materials should be placed at the joints of the condensed water pipes so as to prevent from dew condensation. (As shown in Fig.11) There is an outlet for condensed water on the left and right side of the indoor unit. When the outlet of the condensed water is determined, the outlet on the opposite side should be blocked with a stopper and 11 Install of ducted type indoor unit wrapped with strings so as to prevent the water from leaking. Thermal materials will be used to wrap the sealing properly. Thermal insulation layer water pipe Cover of the pipe Fig.11: Thermal insulation of the condensed water pipe ☆ The outlet for condensed water on the right side is blocked with a stopper when the product leaves the factory. Attention: It must be made sure that there is no leakage at the joints of the condensed water pipes. ● Designing of the Drainage Pipelines ☆ The drainage pipes should be kept at a certain gradient (1/50—1/100) so as to avoid bulges of pipes where there might be water bends. ☆ When connecting the drainage pipes with the unit, care must be taken not to exert too much force on the pipelines of either side of the unit, and the pipes should be fixed as close to the unit as possible. ☆ The drainage pipes can be the locally purchased hard PVC pipes for common purposes. When making the connections, the end of the PVC pipe should be inserted into the drainage hole. Use drainage hose and wire bondage to fix it tightly. It is not allowed to use adhesive glue to join the drainage hole and the drainage tube. ☆ When the drainage pipeline is laid for a couple of units, the position of the shared pipeline should be approximately 100mm lower than the drainage outlet of each unit. In this case, some special-purpose pipes with thicker walls sill be used. ● Installation of Drainage Pipeline 1. Diameter of drainage pipe should not be less than that of connecting pipe.(PE pipes: size: outer diameter 255mm; wall thickness ≥1.5mm) 2. Drain pipe should be as short as possible and its gradient at least should be 1/100 in order to avoid forming air pocket. 12 Install of ducted type indoor unit 3. If there is no enough gradient for discharge hose, riser pipe for drainage should be installed. 4. In order to prevent the discharge hose from bending, mutual distance of hanger brackets should be at least 1.-1.5mm. correct gradient is over wrong 5. Insert discharge hose to drain outlet and then screw the pipe clamp up. 6. For heat insulation, wrap the clamp of discharge hose with sponge. 7. Execute heat insulation to the indoor discharge hose. ● Cautions of Riser Pipe for drainage The installation height of riser pipe for drainage should less than 850mm.It should be perpendicular to the unit and the distance between them should be less than 800mm. hanger bracket ceiling riser pipe for drainage discharge hose accessories clam p accessories 13 Install of ducted type indoor unit Note: ● The height of inclination of attached discharge hose should be within 75mm to prevent the drain outlet from withstanding extra force. ● If multi-discharge hoses converge, please follow the steps below. joints for joined d ischarge h ose S electe d joints for joined discharge ho se sho uld be suitable for run nin g cap a city of the unit. discharge hose accessories ● Test of Drainage System 1. Please test the drainage system after installation of electric appliances. 2. During the test, check if the water correctly flows through the pipeline and observe the joints to make sure that there is no leak. If the unit installs in new house, it is advised to execute the test before decoration of the ceiling. ● Testing on the Drainage System ☆ Upon completion of the installation of the electric appliances, the testing on the drainage system should be performed. ☆ During the testing, it should be made sure that the water flows through the pipeline in the correct direction. Careful observations should be made on the joints to ensure that there is no leakage of water at the joints. ☆ In the case that the unit is to be installed in a new building, it is recommended that the testing be made prior to the decoration of the ceiling. ● Functional DIP switch S7 and Introduction to Address Code ☆ Introduction to Functional DIP Switch S7 and the Setting 14 Install of ducted type indoor unit Caution ! Functional DIP switch S7 locates on the mainboard of indoor unit. Only when the revision of default setting is required by users, it can be operated or its original position should be maintained. Functional DIP switch S7 DIP switch 1(S / R) 2(L / I) Code Setting Description 0 (ON ) Memory mode setting Energized Energized standby recovery (S) (R) Control method Wired control Remote setting (L) control (I) Master 3(M / S) Master/slave indoor unit setting indoor unit (M) Collection point Slave indoor unit(S) Return air 4(I / O) setting for ambient inlet (I) temp. Low static 5(L / H) 1 High-low static setting of fan receiver(O) High static pressure pressure (L) (H) Specific function of each function DIP switch is as follows: DIP switch 1(S/R)——Memory mode setting; it includes energized standby mode and energized recovery mode. Energized standby mode is that: after the unit resumes power supply, the previous setting parameters will be maintained but cannot automatically run and such setting is factory setting (dialing the DIP switch to “ON” position); For example, setting parameters of a indoor unit are high fan speed before de-energization and 24 and after resuming power supply, the unit will be in standby status; Then manually turn on the unit and its parameters are still high fan speed and 24 . Energized recovery mode is that: after the unit resumes power supply, not only it will keep the previous setting but also can automatically run; But if the unit is in turnoff status before de-energization, it will still be that status after resuming power supply. 15 Install of ducted type indoor unit DIP switch 2(L/I)——Control mode; it includes wired control mode and remote control mode. Wired control mode is that: control the running of indoor unit by wired controller, which is factory setting (dialing the DIP switch to “ON” position); When the setting is wired control mode, “Memory mode setting” and “Master/slave indoor unit setting” of S7 are invalid which can be directly set on the wired controller. Remote control mode is that: control the running of indoor unit by remote controller; when the setting is remote control mode, its functional code must be set in S7. DIP switch 3(M/S)——Master/slave indoor unit setting; it is master/slave setting of indoor unit running mode, which is mainly used for people’ priority requirements (such as leaders, patients, etc.). The factory setting is master indoor unit( dialing the DIP switch to “ON” position). When settings of all indoor units are slave indoor units, outdoor unit will run in the mode of firstly started slave indoor unit. If the mode of later started slave indoor unit and mode of firstly started slave indoor unit conflict, the conflict modes error will be warned by the system and later started indoor unit cannot run. In that case, the running of the unit is decided by firstly started slave indoor unit. When there is only one indoor unit that is set to be master indoor unit, in that case, no matter if the master indoor unit is firstly started, the conflict mode error will be warned by slave indoor unit once the mode of slave indoor unit and the mode of master indoor unit conflict (except for turnoff mode of master/slave indoor unit). And the unit will firstly run at the mode of master indoor unit When there are multi indoor units that are set to be master indoor units, the unit will run at the mode of master indoor unit with min. address code. When the indoor unit with min. address code changes to the running status from turnoff status, modes of other master indoor units or slave indoor unit should be in the same mode with it, or the conflict mode error will be warned. Therefore, when there are multi master indoor units, set the address code from high to low according to priority. 16 Install of ducted type indoor unit DIP switch 4(I/O)——Collection point setting of ambient temp.; the setting is mainly used when there is high differential between temperatures of air conditioning area and return air of the unit. The setting is valid only when there is receiver and includes collection points setting of temperatures of return air inlet e and receiver head. The factory setting is the collection points setting of temperature of return air inlet( dialing the DIP switch to the “ON” position. DIP switch 5(L/H)——High-low static pressure setting of fan; it includes high static pressure setting of fan and low static pressure setting of fan, which should be adjusted according to the project. Cautions: 1).Code setting must be under off state of power. 2). There is 3-bit, 4-bit or 5-bit DIP switch. 4-bit or 5-bit DIP switch is only applicable to ducted type unit(including OV Multi VRF ducted type units and ducted type split) 3).; When the control setting is "L", the Master/slave and memory setting on the main board is invalid. When the control setting is “I”, the code setting is valid. 4). The dial-up position shall be at ON which means 0 or at opposite position which means 1. Dial-upswitch at middle position is prohibited. 5). After dialing up, please record address code of the unit (√). S1 address code S7 function code 5-bit functional DIP switch 17 Install of ducted type indoor unit Functional DIP Switch S7 Address Switch S1 DIP Mainboard of 4-bit Functional DIP switch Installation Instruction of the Unit 1. Address Code Address code must be set for multi VRF indoor units to ensure normal communication. The address code is 4-bit. The highest value is 16 and the lowest value is 1. Notice! If multiple indoor units are used at the same time, address setting must be modified before installation. Different address codes must be set for them. If wired controller is used for them, the address code of it (DIP switch at the back of it) must accord with corresponding indoor unit. ☆ Factory setting is as follow: Default setting of address code is 0000 which mean 1 (dial-up method is shown in the above figure.) ☆ Adress value Binary system is used in address code setting, and the value is "0" when the switch is dialed to "ON" while the opposite is "1". The four codes 4~1 on the address code, in which No. 4 is high level bit and No. 1is low level bit. The "4" switch is the first digit while "1" is the last one. 18 Install of ducted type indoor unit Address Value 1 2 3 4 5 6 7 8 Address Position 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Code Address Value 0 0 0 0 1 0 0 0 0 1 0 0 1 1 0 0 0 0 1 0 1 0 1 0 0 1 1 0 1 1 1 0 9 10 11 12 13 14 15 16 Address Position 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Code 0 0 0 1 1 0 0 1 0 1 0 1 1 1 0 1 0 0 1 1 1 0 1 1 0 1 1 1 1 1 1 1 Example 1: Code “0111” represents that the address is “8”. 1,2,3, of the DIP switch should be dialed to the number side and 4 should be dialed to “ON” position. Example 2: Code is “1010” represents that the address is “11”.2,4 of the DIP switch should be dialed to the number side and 1,3 should be dialed to the “ON” position as follows: Address 8,Code0111 Address11 ,Code1010 ● Connection between the Electric Wires and the Terminals on the Te rminal Plate: (As shown in Fig.12) A. Connection of mono-branching wires 1. Use a wire stripper to strip off about 25mm of the insulation layer at the end of the mono-branching wire; 2. Remove the screws on the wiring board of the air conditioner unit; 3. Use the pliers to bend the end of the wire into a ring shape corresponding the size of the screw; 4. Pass the screw through the wire ring and fix it onto the wiring board. 19 Install of ducted type indoor unit B. Connection of multi-ply stranded wires 1. Use the wire stripper to strip off about 10mm of the insulation layer of the stranded wires; 2. Remove the screws on the wiring board of the air conditioner unit; 3. Use the wire pressing pliers to press the ends of the multi-ply stranded wires onto the terminals corresponding to the size of the screws; 4. Pass the screws through the terminals of the multi-ply stranded wires and fixes them onto the A.M ono-branching w ire B. M ulti-ply stranded w ire wiring board. 10 25 W iring term inal Insulation layer Fig.12 Warning: 1. If the power cord or signal cord of the unit is damaged, special-purpose cords must be used for replacement; 2. Please identify the voltages for the components indicated on the nameplate before doing the wire connection, and then connect the wires in accordance with the schematic diagram of wiring. 3. The air conditioner unit should use the special-purpose power cord, and should be equipped with breaker of air switch so as to handle the occurrence of overloads; 4. The air conditioner unit must be properly grounded to prevent from the damages caused by the failure of insulation; 5. All the distribution wires must use the press-connecting terminals or single wires. The direct connection between the multi-ply stranded wires and the terminal board might lead to sparking; 6. All the wiring must follow the schematic diagram for the electric circuits. Any erroneous wiring and connection might result in the abnormal operations or damages of the air conditioner unit; Do not allow the power cord to contact the pipelines or any moving parts like the compressor or fan; 7. The internal wiring of the air conditioner unit should not be altered without authorization. The manufacturer shall not be responsible for any losses or abnormal operations incurred from such unauthorized alterations. 20 Install of ducted type indoor unit ● Connection of Distribution (Communication) Wires: Open the cover of the electric box of the indoor unit; Pass the distribution (communication) wire through the rubber gasket; Insert the distribution (communication) wire into the three pin stands of CN15, CN16 or CN17 on the electric circuit board of the indoor unit; Bind the distribution (communication) wires firmly together and fix them. ● Connection of Power Supply Lines: Attention: The power supply for various indoor units must be from the unified power supply. Air conditioner units using single-phase power supply 1. Remove the cover of the electric box of the indoor unit; 2. Pass the power supply cord through the rubber gasket; 3. Connect the power cord to the L and N terminals as well as the grounding screw; 4. Bind the cord and wires firmly together and fix them properly; ● Connection of Remote controller Signal Wire: 1. Open the cover of the electric box of the indoor unit; 2. Pass the signal line of the remote controller through the rubber ring; 3. Insert the signal line of the remote controller into the four-positioned pin stands on the electric circuit board of the indoor unit; 4. Bind the signal lines of the remote controller firmly together and fix them. Attention: Special precaution must be taken when doing the following connections so as to prevent from the failure of the air conditioner unit due to EMI (electromagnetic interference). 1. The signal lines and the distribution (communication) wires should be separated from the power supply cord and the connection lines between the indoor and the outdoor units; 2. In the case that the air conditioner unit has to be installed at the places subject to the EMI, it is advised to use shielded and double-strand wires for the signal lines and distribution (communication) wires. ● Others 1.Tomodelsof OV(L)-R22P/NaB-K,OV(L)-R28P/N aB-K,OV(L)-R36P/NaB-K, OV(L)-R45P/NaB-K, OV(L)-R56P/NaB-K, OV(L)-R71P/NaB-K, OV(L)-R90P/NaB-K, OV(L)-R112P/NaB-K,OV(L)-R140P/NaB-K,OV(L)-R22PS/NaB-K, OV(L)-R28PS/NaB-K,OV(L)-R36PS/NaB-K, OV(L)-R45PS/NaB-K, OV(L)-R56PS/NaB-K,OV(L)-R71PS/NaB-K, OV(L)-R90PS/NaB-K, OV(L)-R112PS/NaB-K,OV(L)-R140PS/NaB-K, OV(L)-R22P/HB-K,OV(L)-R28P/HB-K,OV(L)-R36P/HB-K, OV(L)-R45P/HB-K, OV(L)-R56P/HB-K,OV(L)-R71P/HB-K, OV(L)-R90P/HB-K, OV(L)-R112P/HB-K,OV(L)-R140P/HB-K, OV(L)-R22PS/HB-K,OV(L)-R28PS/HB-K,OV(L)-R36PS/HB-K, OV(L)-R45PS/HB-K, OV(L)-R56PS/HB-K,OV(L)-R71PS/HB-K, OV(L)-R90PS/HB-K, OV(L)-R112PS/HB-K ,OV(L)-R140PS/HB-K、OV(L)-R22P/NaB-D,OV(L)-R28P/NaB-D, OV(L)-R36P/NaB-D, OV(L)-R45P/NaB-D, OV(L)-R56P/NaB-D,OV(L)-R71P/NaB-D, OV(L)-R90P/NaB-D, OV(L)-R112P/NaB-D, OV(L)-R140P/NaB-D according to requirements of the project, when it is necessary for higher static pressure, realize it by changing indoor wire connection according to the enclosed circuit diagram. 21 Name and Function of Each Part of Ducked Type Indoor Unit RECTANGLE OUTLET VENT CIRCLE OUTLET VENT DUCTED TYPE INDOOR UNIT ① ② ③ Outlet vent Air return vent Condensation Pipe NOTE: 1.Connection pipe and Air pipe are not included in this Air conditioner 2. Products are set for the rectangle outlet vent. Working Temperature Range Working Temperature Range Indoor side state Dry bulb temp. Wet bulb temp. Outdoor side state Wet bulb temp. Dry bulb temp. Rated Cooling 27 19 35 24 Max. cooling 32 23 43 26 Min. cooling 21 15 18 — Rated Heating 20 15 7 6 Max. heating 27 — 24 18 Min. heating 20 15 -15 -16 22 Wired Remote Controller Operation Procedure MODE FAN SLEEP TIMER ON/OFF Various Components of Wired Remote Controller 1 Operating mode display (Cool, Dry, Fan, Heat) 9 On/Off button 2 Sleep mode display 10 Timer button 3 Environmental temp. display /Malfunction display 11 Sleep button 4 Fan control display (automatic, high, media, low) 12 Swing display 5 Set Temp. display 13 Fan control button 6 Defrosting display 14 Temp./ Timer decrease button 7 Timer display 15 Temp./ Timer increase button 8 Signal receptor 16 Mode button 1) On/Off(Fig.13) ● ● When press the ON/OFF key,the unit will start. MODE When press ON/OFF key again,the unit will stop. NOTE:Fig.13 shows the closedown status after power on. When the communication is normal, both at the running and stopping status will FAN display the environment temp. Here,there is no“graticule line”on the SLEEP LCD of Fig.14,it shows the unit is closedown.. TIMER ON/OFF Fig.13 23 Wired Remote Controller Operation Procedure 2)Timer setting (Fig.14,hereinafter will be displayed according to the function of the wired remote controller.) MODE ● At stopping, press TIMER ON button, set ON TIME, at operating, press TIMER OFF button, set OFF TIMER. ● When it is not timed(i.e. there is no show content in the timing FAN display field ) ,press TIMER ON,the liquid will display the SLEEP pattern of “ ” and “HOUR”the samples TIMER will be flashed in every 0.5second on and on,at this time press ON/OFF xx.x hour”, “ or button to set time。After using or Fig.14 button,adjust to the desired temperature, then press the TIMER button,at this time“ ”and“HOUR”will not flash,that shows the TIMER ON has been set. ● After power on, to press the TIMER button once,LCD will display“ 0.0 HOUR”,The sign of“ ”and “HOUR”will twinkle,when repress the TIMER button,the LCD will not display the sign,that shows the TIMER ON has been canceled. ● When the TIMER ON has been set,(i.e. the sign of“ TIMER button once more,LCD will show “ xx.x HOUR” (Note: “xx.x”is the time of last setting,after power on it will be cleared automatically),the sign of“ press ● or ”and “HOUR”will twinkle continuously),if press the ”and“HOUR”will twinkle continuously,at this time could button for time setting,or press the TIMER button again to confirm the function of time. The range of TIMER ON and TIMER OFF is from 0.5hour to 24hour. Press or button for each time, the set time will be increased or decreased 0.5hour, hold the press or button, it will increase 0.5hour or decrease 0.5hour every other 0.5second. The setting range of 0 to 24,and they are circulatory. button: button: 0.0 0.0 0.5 0.5 1.0 1.0 ········ 23.5 24.0 ······ 23.5 24.0 NOTE:The Fig. shows the relevant display area. 24 and is from Wired Remote Controller Operation Procedure 3 )SLEEP mode setting (Fig.15) ● When PCB is running at COOL or DRY mode,after received the SLEEP mode setting and run for 1 hour,the preset MODE temperature Tset will be increased 1 increased 1 ,2 hours later it will be again,it has been increased 2 totally within 2 hours,then the unit will run accord to the setting temperature. ● FAN When the PCB is running at HEAT mode,after received the SLEEP SLEEP mode setting and run for 1 hour,the preset TIMER temperature Tset will be decreased 1 ,2 hours later the Tset will be decreased 1 ON/OFF again,it has been decreased 2 totally within 2 hours,then the unit will run accord to the Fig.15 setting temperature. ● There is no SLEEP function in FAN mode. 4)Fan Speed Control(Fig.16) ● Press FAN SPEED button each time,fan speed will be changed as following: AUTO LOW MODE MED HIG FAN ● AT DRY mode :The fan speed will be set to the LOW speed SLEEP automatically. TIMER ON/OFF Fig.16 25 Wired Remote Controller Operation Procedure 5) Temp. adjusting (Fig.17) ● When not setting the time,press and button,can set the MODE temperature adjustment. For increasing setting temperature; For decreasing setting temperature。 FAN (When press this button,the temperature will be increased or SLEEP decreased in the unit of 1 ● The temperature setting range is 16 30 TIMER at every kind off ON/OFF modes 6)Set of running mode(Fig.18) ● Fig.17 When pressing MODE button each time,the mode will be changed as following: COOL ● DRY FAN MODE HEAT At “COOL” mode,the COOL display will be light on,the FAN temperature of setting should be lower than the room SLEEP temperature. If the setting temperature is higher than the room TIMER sensor,the unit will not run at cool mode operation. ● ON/OFF At “DRY” mode,the DRY display will be light on. Fan motor will run at low fan speed in the definite temperature range. The Fig.18 dehumidifying effect of this mode is better than that in COOL mode and more energy saving. ● MODE At “HEAT” mode,the HEAT display will be light on. The temperature should be set higher than the room temperature; If the setting temperature is lower than the room temperature, the ● unit will not run at HEAT mode operation. FAN At“FAN”mode,the FAN display will light on. SLEEP 7)Malfunction display(Fig.19) ● TIMER When the malfunction happened during the operation, the ON/OFF environment temperature display area will show the error code. As shown in Fig.19 it shows the compressor high-pressure protection. ● When the malfunction happened,except for the FAN mode is in operation,at the mode of COOL, DRY, HEAT ,the outdoor unit and fan motor are closedown, that will not affect the LCD display. 26 Fig.19 Wired Remote Controller Operation Procedure ● When the controller displays malfunction,please turn off the unit to stop the malfunction display,ask for the professional to debug. The meaning of error codes as shown in below: Malfunction code Malfunction E1 High pressure protection of compressor E2 Indoor anti-frozen protection E3 Low pressure protection of compressor E4 Discharge temp. protection of compressor E5 Compressor overload protection E6 Transmit malfunction E7 Modes conflict F0 Fb Indoor environment temp. sensor mal-function Indoor pan tube inlet tube temp. sensor malfunction Indoor pan tube middle temp. sensor malfunction Indoor pane tube outlet tube temp. sensor malfunction Outdoor environment temp. sensor mal-function Outdoor pan tube inlet tube temp. sensor malfunction Outdoor pan tube middle temp. sensor malfunction Outdoor pan tube outlet tube temp. sensor malfunction Discharge temp. sensor 1 (rated frequency) malfunction Discharge temp. sensor 2 (digital) malfunction Greasy temp. temp. sensor 1 (rated frequency) malfunction Greasy temp. temp. sensor 2 (digital) malfunction FC High pressure sensor malfunction Fd Low pressure sensor malfunction F1 F2 F3 F4 F5 F6 F7 F8 F9 FA 27 Ambient Temp Sensor Mode Setting of Indoor Unit Under off state of unit, press FAN and SLEEP /SWING buttons at the same time for 5s into setting interface, as shown in Fig.20.”01” is displayed in ambient temp displaying area and setting mode code is displayed in temp displaying area which can be adjusted by pressing or , 4 kinds of selection: ①、 Indoor ambient temp is air inlet temp and setting temp area displays 01, as shown in Fig.21. ②、 Indoor ambient temp is wired controller temp and setting temp area displays 01, as shown in Fig.22. ③、 Under heating mode, select wired controller’s temp sensor or under other modes select air inlet’s temp sensor and setting temp area displays 03, as shown in Fig.20. ④、 Under heating mode, select air inlet’s temp sensor or under other modes select wired controller’s temp sensor and setting temp area displays 04, as shown in Fig.23. Factory default is the third mode. Fig.20 Fig.21 Fig.22 Fig.23 28 Remote controller operation procedure Names and functions of every button of the remote control NOTE! ● Make sure that there is no obstruction between the remote control and the signal receptor. ● The remote control signal can be received at the distance of up to about 10m. ● Don’t drop or throw the remote control. ● Don’t let any liquid flow into the remote control. ● Don’t put the remote control directly under the sunlight or any place where is very hot. SWING button the guide louver swings according to certain angle when press once; repress once to stop operating. FAN button Press the button to change the speed of the fan according to the following order. SWING FAN AUTOFAN TEMP. button Set temp. increases 1 c by pressing "+" and decreases 1 c by pressing "-" once. Set temp. : 16 c~30 c Set temp. : 16 c~30 c AUTO FAN SPEED OPER AUTO AIR SWINGHUMIDLIGHT SAVE TIMER ONOFF HR. COOL DRY FAN HEAT Set temp. : 16 c~30 c Set temp. : 16 c~30 c on/off button Press the button to turn on the unit. Press the button once again to turn off the unit and cancal the timer. MODE button Press the button to change the mode according to the following order MODE ON/OFF NOTE: The cooling only units have no mode. NOTE! After every indoor unit received the turn off signal, the fan and electric inflate valve will continue to work for 20-70mins to make use of the rest cool or rest heat, while for preparation for the next work. And this is normal phenomenon. 29 Remote controller operation procedure Names and functions of every button of the remote control (Remove the cover) NOTE! This type of remote control is a kind of general use remote control that is suitable for several types (function) of air conditioner units. Please understand that the functions and buttons that are not suitable for this air conditioner will not be introduced. Liquid crystal displayer It shows all set contents. SWING FAN AUTOFAN SLEEP button Press the button to set SLEEP mode, and stop when repressed. When the sleep mode is in the cool and dry mode, the set temp. will increases 1~2 during the set time, then the unit will operate according to the temp.. When sleep mode is in the heat mode, the set temp. decreases 1~2 during the set time, then the unit will operate according to the set temp.. OPER AUTO AIR SWING HUMID LIGHT SAVE TIMER ONOFF HR. SLEEP AIR LIGHT HUMID TIMER ONTIMER OFF ANION SAVE MODE ON/OFF Temp./Timer button When the unit is operating, increase 1 by pressing "+" button once, and decrease 1 by pressing "-" button once. The indoor temp. can be set in the range of 16-30 . Press the "Timer OFF/TIMER ON" button at operating/ stopping to set the off/on time. Press "Timer OFF/TIMER ON" once to increase 0.5 hour for the set time. The longest set time is 24 hours; repress it once to cancel timer. 30 Remote controller operation procedure Operation procedure Normal procedure 1. Press ON/OFF button after connected with the power, then the unit is operating. 2. Press MODE button to choose the need operation mode. 3. Press FAN button to set the fan speed. 4. Press +/- button to set the need temp.. Selectable procedure 5. Press SLEEP mode to set the sleep state. 6. Press TIMER OFF button to set the set time. Note: When the operating mode selected by the indoor unit is clash with the one selected by the outdoor unit, the remote controller will display the operating clash after 5 seconds and the power light will flicker, then the indoor unit turns off. At this time, the units will become normal after the operating mode of the indoor unit is changed to cooperate with the outdoor unit. Cool mode can cooperate with dry mode, and fan mode can cooperate with any mode. How to insert batteries Two batteries (Two AAA dry-cell batteries) are used by the remote control 1. Remote the cover from the back of the remote control downward, take out the worn batteries and insert two new ones (Make sure the two poles are correct) 2. Re-attach the cover. ACL 1.All the prints and code no. will be showed on the displayer after the insert of batteries. The remote control can be operated after 10sec. 2.The lifetime of the batteries is about one year. 3.Don't confuse the new and worn or different types of batteries. 4.Remove batteries when the ①Remove the cover remote control is not in use for a ③Re-attach the cover longtime to avoid mal-function caused by liquid leakage. 5.The remote control should be placed about 1m or more from the open TV set or any other electric appliances. 6.The remote control should be used in the receivable range (the RESET KEY reception range is 10m) 7.When the remote control can not be controlled in the situation of inserted batteries, please remove the back cover and press "ACL" button to make it normal. ②Insert 2AAA dry-cell battaries(attachment) 31 Trouble Shooting If the malfunction occurs, please check item shown below before requesting on service center. Phenomenon Cause 1. The power supply is not connected The unit can’t start well. 2. The electrical leakage cause the jump 3. The voltage is too low. Although the unit can run, 1. The inlet vent and outlet vent are after a while it will stop. blocked 1. The air filter is dirty or blocked 2. There are heat sources in the air conditioner room or too many people in this room. The cooling effect is not good. 3. The door or window is opened. 4. There are obstructions in the air inlet or outlet grille. 5. The set temp. is too high, that will affect the cooling effect. 1. The air filter is too dirty, or blocked. 2. The door or window isn’t closed well. The heating effect is not good. 3. The set temp. is too low, that will affect the heating effect. 1. When replacing batteries or under other conditions, sometimes the “Machine Death” phenomenon is shown on the remote controller, please remove the rear cover, then press “ACL”(reset key), the unit will get back 2. Is it in the receiving range? Or are The remote controller can not there any obstructions? work 3. For the ducted type indoor unit, the remote controller should be aimed at the wired remote control for the control. 4. To check the voltage of batteries is enough or not, if not enough please change it. NOTE: After checking the above items, the unit still can’t be operated, please turn off the unit immediately and contact with the local service center and ask for the professional to maintain. 32 Care and Maintenance ATTENTION:Please pay more attention to the following items before cleaning the units z The general power supply of the indoor units must be powered off before contacting the wiring device; z Only when unit is turned off and the general power supply is cut off, the unit could be cleaned, otherwise it might cause the electric shock or injury; z Do not use water to clean air conditioners, or it may cause electric shock; z Especially when cleaning the units you should pay more attention, to stand on the firm place. Daily Care (1)Clean the air filter z When not cleaning the air filter please do not disassembly the filter, or it will cause the malfunction. z When there is a lot of dust, the air filter should be cleaned many times (generally once for every two weeks) (2)The care of the season begin to use z Check the inlet and outlet of the indoor units blocked or not; z Check the wires earthed well or not; z Check the lines connected well or not; z After switching on, the indicator lights of the wired remote control should light. NOTE: If there is any abnormal phenomenon, please operate the unit under the direction of after service. (3)The care of the season end to use z When the weather is fine, set the unit in the fan mode and running for half of the day. z When not to use the unit for a long time, please switch off the power supply, the indicator light of the wired remote control should extinguish. 33
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement