a+ abcde a+ abcde
Outdoor unit
MXZ-5E102VA
unit1/2/3 MSZ-EF18/18/22VE
Model Indoor
Indoor unit4/5 MSZ-EF22/22VE
SEER
SCOP
A++
++
A+++
A+++
A+
B
C
D
E
kW 10,2
SEER 6,6
kWh/annum 537
++
A+++
A+++
A+
B
C
D
E
A+
X
SCOP X
kWh/annum X
kW
8,9
4,2
2958
X
X
X
Indoor unit1/2/3
Indoor unit4/5
60dB
Outdoor unit
65dB
626/2011
WG79A641H01
WG79A642H01
MXZ-4E83VA
1
2
3
4
5
6
1
2
3
4
5
6
MXZ-5E102VA
MSZ-EF18VE
MSZ-EF18VE
MSZ-EF18VE
MSZ-EF18VE
MSZ-EF22VE
MSZ-EF22VE
MSZ-EF25VE
MSZ-EF22VE
_
MSZ-SF15VA
MSZ-EF22VE
_
_
MSZ-SF15VA
MSZ-EF18VE
61
65
60
60
60
60
60
60
60
60
_
60
60
_
_
60
60
R410A GWP 1975 *1
6,3
6,6
A++
A++
460
537
8,3
10,2
4,2
4,2
A+
A+
2884
2958
8,7
8,9
7,13 (-10°C)
7,30 (-10°C)
7,80 (-7°C)
7,90 (-7°C)
6,00 (-15°C)
6,30 (-15°C)
1,57
1,60
WG79A642H01
PRODUCT INFORMATION (*)
INDOOR MODEL 1/2/3 ROOM AIR CONDITIONER INDOOR MODEL 4/5/6
OUTDOOR MODEL
MSZ-EF18VE / MSZ-EF18VE / MSZ-EF22VE
MSZ-EF22VE / MSZ-EF22VE / MXZ-5E102VA
If function includes heating: Indicate the heating season the
information relates to, Indicated values should relate to one
heating season at a time, Include at least the heating season
Y
Average (mandatory)
N
Warmer (if designated)
N
Colder (if designated)
Function (indicate if present)
cooling
heating
Item
Design load
cooling
heating/Average
heating/Warmer
heating/Colder
Y
Y
symbol
value
unit
Pdesignc
Pdesignh
Pdesignh
Pdesignh
10.2
8.9
x
x
kW
kW
kW
kW
Item
Seasonal efficiency
cooling
heating/Average
heating/Warmer
heating/Colder
symbol
SEER
SCOP/A
SCOP/W
SCOP/C
value
unit
6.6
4.2
x
x
-
Declared capacity for cooling, at indoor temperature 27(19)℃
and outdoor temperature Tj
Tj=35℃
Pdc
10.20
kW
Tj=30℃
Pdc
7.60
kW
Tj=25℃
Pdc
5.00
kW
Tj=20℃
Pdc
4.30
kW
Declared energy efficiency ratio, at indoor temperature
27(19) ℃ and outdoor temperature Tj
Tj=35℃
EERd
3.24
Tj=30℃
EERd
5.80
Tj=25℃
EERd
8.70
Tj=20℃
EERd
10.50
Declared capacity for heating/Average season, at indoor
Declared coefficient of performance/Average season, at
temperature 20℃ and outdoor temperature Tj
Tj=-7℃
Pdh
7.90
Tj=2℃
Pdh
4.90
Tj=7℃
Pdh
5.60
Tj=12℃
Pdh
5.80
Tj=bivalent temperature
Pdh
7.90
Tj=operating limit
Pdh
6.30
indoor temperature 20℃ and outdoor temperature Tj
Tj=-7℃
COPd
2.50
Tj=2℃
COPd
4.33
Tj=7℃
COPd
6.00
Tj=12℃
COPd
7.40
Tj=bivalent temperature
COPd
2.50
Tj=operating limit
COPd
2.30
-
Declared capacity for heating/Warmer season, at indoor
temperature 20℃and outdoor temperature Tj
Tj=2℃
Pdh
x
kW
Tj=7℃
Pdh
x
kW
Tj=12℃
Pdh
x
kW
Tj=bivalent temperature
Pdh
x
kW
Tj=operating limit
Pdh
x
kW
Declared coefficient of performance/Warmer season, at
indoor temperature 20℃ and outdoor temperature Tj
Tj=2℃
COPd
x
Tj=7℃
COPd
x
Tj=12℃
COPd
x
Tj=bivalent temperature
COPd
x
Tj=operating limit
COPd
x
-
Declared capacity for heating/Colder season, at indoor
temperature 20℃and outdoor temperature Tj
Tj=-7℃
Pdh
x
Tj=2℃
Pdh
x
Tj=7℃
Pdh
x
Tj=12℃
Pdh
x
Tj=bivalent temperature
Pdh
x
Tj=operating limit
Pdh
x
Tj=-15℃
Pdh
x
kW
kW
kW
kW
kW
kW
kW
Declared coefficient of performance/Colder season, at indoor
temperature 20℃ and outdoor temperature Tj
Tj=-7℃
COPd
x
Tj=2℃
COPd
x
Tj=7℃
COPd
x
Tj=12℃
COPd
x
Tj=bivalent temperature
COPd
x
Tj=operating limit
COPd
x
Tj=-15℃
COPd
x
-
Bivalent temperature
heating/Average
heating/Warmer
heating/Colder
-7
x
x
℃
℃
℃
Operating limit temperature
heating/Average
Tol
heating/Warmer
Tol
heating/Colder
Tol
x
x
0,25
kW
kW
-
Cycling interval capacity
for cooling
for heating
Degradation co-efficient
Tbiv
Tbiv
Tbiv
Pcycc
Pcych
Cdc
kW
kW
kW
kW
kW
kW
Cycling interval efficiency
for cooling
for heating
Degradion co-efficient
EERcyc
COPcyc
Cdh
-
-15
x
x
℃
℃
℃
x
x
0,25
-
537
2958
x
x
kWh/a
kWh/a
kWh/a
kWh/a
Electric power input in power modes other than 'active mode'
off mode
POFF
15
W
standby mode
PSB
15
W
thermostat - off mode
PTO
28
W
crankcase heater mode
PCK
0
W
Annual electricity consumption
cooling
QCE
heating/Average
QHE
heating/Warmer
QHE
heating/Colder
QHE
Capacity control (indicate one of three options)
Other items
fixed
N
Sound power level
(indoor1-4/outdoor)
LWA
60/65
dB(A)
staged
N
Global warming potential
GWP
1975
kgCO2eq,
Y
Rated air flow
(indoor1-4/outdoor)
-
630/4080
m3/h
variable
Contact details for
obtaining more information
MITSUBISHI ELECTRIC CORPORATION
SHIZUOKA WORKS
3-18-1, Oshika, Suruga-ku, Shizuoka 422-8528, Japan
E-mail: [email protected]
(*) This information is based on the "product information requirement" in COMMISSION REGULATION (EU) No206/2012,
TECHNICAL DOCUMENTATION ( 1)
INDOOR MODEL 1
INDOOR MODEL 2
INDOOR MODEL 3
ROOM AIR CONDITIONER INDOOR MODEL 4
INDOOR MODEL 5
INDOOR MODEL 6
OUTDOOR MODEL
MSZ-EF18VE
299H885W195D (mm)
MSZ-EF18VE
MSZ-EF22VE
MSZ-EF22VE
MSZ-EF22VE
MXZ-5E102VA
299H885W195D (mm)
299H885W195D (mm)
299H885W195D (mm)
299H885W195D (mm)
796H950W330D (mm)
Function
cooling
heating
Y
Y
The heating season
Average (mandatory)
Warmer (if designated)
Colder (if designated)
Y
N
N
Capacity control
fixed
staged
variable
N
N
Y
symbol
value
unit
SEER
SCOP/A
SCOP/W
SCOP/C
6.6
4.2
x
x
-
Energy efficiency class
cooling
heating/Average
heating/Warmer
heating/Colder
SEER
SCOP/A
SCOP/W
SCOP/C
A++
A+
x
x
-
Other items
Sound power level (indoor1-4/outdoor)
Refrigerant
Global warming potential
LWA
GWP
60/65
R410A
1975
dB(A)
kgCO2eq,
Item
2
Seasonal efficiency ( )
cooling
heating/Average
heating/Warmer
heating/Colder
identification and signature
of the person empowered
to bind the supplier
Hideyo Tamura
Manager,
Packaged Air Conditioners Quality Control Section
(1) This information is based on COMMISSION DELEGATED REGULATION (EU)No626/2011,
(2) SEER/SCOP values are measured based on FprEN 14825:2011: Testing and rating at part load conditions and calculation of seasonal performance,