focfiber in LooSe tUbe coLor coDeS

focfiber in LooSe tUbe coLor coDeS
fiber optic cables fibrain
Information
Application
FOC Parameters
Low Loss Fibers
SM/MM Bendsafe Fibers
Fiber and Cables Information
Fiber Identification
Page 5
Page 5
Page 6
Page 7
Page 8
Page 9
Page 10
DATACOM
Page 16
FTTH
Page 34
Furcation tube FSMX
Buffer BFR
Simplex SMX
Duplex ZIP
LDC
LBR
DC-PRIM
DC-DRIM
EXO-CU
EXO-C0
EXO-CI
EXO-GU
EXO-G0
EXO-GI
BDC-MSA
VC-D20
VC-D30
VC-D40
VC-DCY
ResibendTM Cables
VC-D30 ResibendTM
VC-D30 Resibend PlusTM
Easy Section Module Cables
VC-D30 Easy Section Module
VC-D40 Easy Section Module
DC-PRIM
EAC-RAs
EAC-RAm
DAC-BURRY
VC-T60
Aero-DF03
Page 17
Page 18
Page 19
Page 21
Page 22
Page 23
Page 24
Page 25
Page 26
Page 27
Page 28
Page 29
Page 30
Page 31
Page 32
Page 35
Page 36
Page 37
Page 38
Page 39
Page 40
Page 41
Page 42
Page 43
Page 44
Page 45
Page 46
Page 47
Page 48
Page 49
Page 50
content
5
16
34
fiber optic cables fibrain
MICRODUCT
Page 51
Telecom Duct
Page 63
Telecom Aerial
Page 71
Special Cable Designs
Page 83
MK-AX2
MK-DX2/25/3
MK-LX4
MK-LXS6/7/8
MK-LXS9/10
MK-LX6
MK-LX7
MK-LX8
MK-LX9
MK-LX11
BDC-MSA
BDC-MIB
BDC-C0
BDC-CI
BDC-CK
DDC-SI
DDC-CI
Aero-DF03
Aero-AS02 2.0 mm
Aero-AS03 2.0 mm
Aero-AS03 2.5 mm
Aero-AS04 2.0 mm
Aero-AS04 2.5 mm
Aero-AS06 2.0 mm
Aero-AS06 2.5 mm
Aero-AS09 2.5 mm
Aero-AS12 2.5 mm
Aero-AS14 2.5 mm
FTTA-DAC
BDC-CIP 1.5 mm2
BDC-CIP 0.5 mm2 H05V-U
BDC-CIP 0.75 mm2 H05V-U
BDC-CIP 1.00 mm2 H05V-U
BDC-DIP 1.50 mm2 H07V-U
BDC-DIP 2.50 mm2 H05V-U
BDC-DID 0.80 mm
Page 53
Page 54
Page 55
Page 56
Page 57
Page 58
Page 59
Page 60
Page 61
Page 62
Page 64
Page 65
Page 66
Page 67
Page 68
Page 69
Page 70
Page 72
Page 73
Page 74
Page 75
Page 76
Page 77
Page 78
Page 79
Page 80
Page 81
Page 82
Page 84
Page 85
Page 86
Page 87
Page 88
Page 89
Page 90
Page 91
content
51
63
71
83
Information
Mechanical features
symbols
Basic Rodent
Protection
High Rodent
Protection
Rodent
Protection
Extreme
Flexible
Last mile
connection outdoor
Aerial
Hi-crush
Direct buried
Duct
Microduct
Generation 1
ETR
Industrial
Mining
Military
Oil resistance
Ship
and offshore
Robotic
Windfarms
Datacenter
Datacom
Telecom
FTTH
FTTA
Semi-tight
Easy-strip
LSOH
Compact design
Flexible
Multifiber
connectors
termination
Easy to terminate
Last mile
connection indoor
Bendsafe
Low Friction
Blowing
installation
Design features
Branch of business
Optimal
Diameter
Hybrid FO
+ Power
symbols | 5
FOC
FOC Parameters
parameters
single-mode fiber types
Fiber types and applications
Maximum attenuation for uncabled fibers
IL [dB/km]
Fiber type
ITU-IT
Possibility to remove the 900 μm coat at the
distance of 3-5 cm
1383 nm
1410 nm
1450 nm
1490 nm
≤0.34
≤0.31
-
-
≤0.24
≤0.20
≤0.23
Premium single mode fiber low loss
G.652D LL with zero water-peak and lower
attenuation in whole bandwidth
≤0.32
≤0.31
-
-
≤0.21
≤0.18
≤0.20
Long distance single mode fiber
with non-zero dispersion shifted
G.655 –
(NZDSF) for CWDM and DWDM
A,B,C,D
system 10G
and future 40G or 100G
-
≤0.40
≤0.32
≤0.26
-
≤0.19
≤0.21
Long distance single mode fiber
G.656 – with non-zero dispersion shifted
A,B,C,D (NZDSF) for CWDM and DWDM
system 10G and future 40G or 100G
-
≤0.40
≤0.32
≤0.26
-
≤0.19
≤0.21
Available bend radius
Bend insensitive fiber fully
G.657A1 compatible with G.652D standard,
bend radius 10-15 mm
≤0.35
≤0.35
-
-
≤0.24
≤0.20
≤0.23
BEND RADIUS
Bend insensitive fiber fully
G.657A2 compatible with G.652D standard,
bend radius 7.5 mm
≤0.35
≤0.35
-
-
≤0.24
≤0.20
≤0.23
Bend insensitive fiber fully
G.657B3 (A3) compatible with G.652D standard,
bend radius 5 mm
≤0.35
≤0.35
-
-
≤0.24
≤0.20
≤0.23
Bend insensitive fiber, non-compatible with G.652D standard, for
G.657B3 Plus
connectorization application, bend
radius 2.5 mm
≤0.35
Standard single mode telecommuG.652D nication fiber with zero water-peak
attenuation
-
≤0.35
-
1550 nm 1625 nm
Tight 900 μm fiber
1310 nm
≤0.24
≤0.21
≤0.23
Semi-tight 900 μm fiber
Possibility to remove the 900 μm coat at the
distance of 10-20 cm
Easy strip 900 μm fiber
Possibility to remove the 900 μm coat at the
distance of 100-150 cm
7.5
BEND RADIUS
10
mm
mm
BEND RADIUS
BEND RADIUS
15
mm
30
mm
multimode fiber types
BEND RADIUS
Overfilled
modal
bandwidth
[MHz/km]
Fiber
type
ITU-T
Fiber Capacity
[m]
Attenuation
[dB/km]
Bending loss
2 turns [dB]
Bending loss
10 turns [dB]
Radius = 7.5 mm Radius = 15 mm
Radius = 30 mm
850
nm
40GBASE1300
SR4/
1GBase-SR 10GBase-SR
nm
100GBASESR10
850
nm
1300
nm
62.5/125
OM1
≥ 160
≥
500
275
-
-
2.6
0.5
50/125
OM2 Bend
Insensitive
≥ 500
≥
500
600
83
-
2.3
0.5
≥ 0.2
≥ 0.5
≥ 0.1
≥ 0.3
-
50/125
OM3 Bend
Insensitive
≥
1500
≥
500
1000
300
140*
2.4
0.5
≥ 0.2
≥ 0.5
≥ 0.1
≥ 0.3
-
50/125
OM4 Bend
Insensitive
≥
3500
≥
500
1100
550
170*
2.4
0.6
≥ 0.2
≥ 0.5
≥ 0.1
≥ 0.3
-
850
nm
1300
nm
850
nm
1300
nm
-
850 nm 1300 nm
≥ 0.5
* Maximum cabled fiber attenuation 3.0 dB/km at 850 nm, maximum total connector loss of 1.0 dB and VCSELs maximum RMS spectral width of 0.29
nm (according to IEEE 10GbE model: http://grouper.ieee.org/groups/802/3/ae/public/adhoc/serial_pmd/documents/10GEPBud3_1_16a.xls).
Bending loss
G.652D
Mandrel R=30 mm 100 turns
1550/1625 nm ≤0.03 dB
Mandrel R=25 mm 1310/1550 nm 100 turns
0.03 dB
Mandrel R=15 mm 10 turn
1550 nm ≤0.25 dB 1625 nm ≤1.0 dB
G.652D LL
Mandrel R=30 mm 100 turns
1550/1625 nm ≤0.03 dB
Mandrel R=25 mm 1310/1550 nm 100 turns
0.03 dB
Mandrel R=15 mm 10 turn
1550 ≤0.25 dB 1625 nm≤1.0 dB
G.655 – A.B.C.D
Mandrel R=30 mm 100 turns
1550/1625 nm ≤0.05dB
Mandrel R=15 mm 1550/1625 nm 1 turn
≤0.5 dB
G.656 – A.B.C.D
Mandrel R=30 mm 100 turns
1550/1625 nm ≤0.05 dB
Mandrel R=15 mm 1550/1625 nm 1 turn
≤0.5 dB
G.657A1
Mandrel R=15 mm 10 turns
Mandrel R=10 mm 1 turn 1550 nm
1550nm≥0.20 dB. 1625 nm ≤0.50 dB ≥0.50 dB. 1625 nm ≤1.50 dB
G.657A2
Mandrel R=15 mm 10 turns
Mandrel R=10 mm 1 turn
1550 nm≥0.03 dB. 1625nm ≤0.10 dB 1550 nm≥0.10 dB. 1625 nm ≤0.2dB;
Mandrel R=7.5 mm 1 turn
1550 nm ≥0.50 dB. 1625 nm ≤1.0 dB
G.657B3 (A3)
Mandrel R=10 mm 1 turn
Mandrel R=7.5 mm 1 turn 1550 nm
1550 nm≥0.03 dB. 1625 nm ≤0.10 dB ≥0.05 dB. 1625 nm ≤0.15 dB
Mandrel R=5 mm 1 turn
1550 nm≥0.10 dB. 1625 nm ≤0.30 dB
G.657B3 Plus
Mandrel R=5 mm 1 turn
Mandrel R=2.5 mm 1 turn 1550 nm
1550 nm≥0.10 dB. 1625nm ≤0.20 dB ≥0.20 dB. 1625 nm ≤0.30dB
40
mm
BEND RADIUS
60
mm
low loss
Low Loss Fibers
fibers
At present, low loss and pure quartz optic fibers with max. 0.17 dB/km
attenuation at 1550 nm wavelength and max. 0.31 dB/km at 1310 nm
wavelength are ready for use. Low loss and pure quartz optic fibers have at
least 0.02 dB/km lower spectral attenuation in comparison to the standard
ones G.652D. In such fibers, the retention of flat spectral characteristics
within the transmission windows provide the possibility of achieving substantially smaller deviations of attenuation:
ÆÆ 1310 nm (+ 20 nm / -35 nm) wavelength – max. deviation is 0.03
dB/km
ÆÆ 1550 nm ( + 25 nm / -25 nm) wavelength – max. deviation is 0.02
dB/km with the retention of 1625 nm attenuation 0.20 dB/km.
The chromatic dispersion complies with ITU-T G.652 and the polarizing at the level of ≤ 0.04 ps/√km of these fibers provides the possibility of using such fibers in high- speed systems e.g. transmission
of 10 GBit/s or even higher. Low loss fibers which are obtained
in the pure quartz technology can work properly in telecommunication networks at the distance of even thousand kilometers far, which
significantly limits the number of necessary amplifiers and repeaters
in a fiber optic connection.
0.40
0.30
G.657.A1
G.652.D LL
G.652.D
G.657.A1
G.652.D LL
G.652.D
G.657.A1
G.652.D LL
G.652.D
G.657.A1
G.652.D LL
G.652.D
0
G.657.A1
0.10
G.652.D LL
0.20
G.652.D
Attenuation [dB/km]
Attenuation / Wavelength
25
16
50
15
90
14
83
13
10
13
Wavelength [nm]
low loss Fibers Introduction | 7
low loss
Low Loss Fibers
fibers
Performance Specifications
Parameter
Value
Attenuation [dB/km]
1310 nm
1383 ± 3 nm
1490 nm
1550 nm
1625 nm
≤ 0.32
≤ 0.32
≤ 0.21
≤ 0.18
≤ 0.20
Attenuation Difference [dB/km]
The attenuation from λ1 [nm] to λ2 [nm] shall not exceed the attenuation at λ3 [nm] by more than Δ
λ1
1285
1525
λ2
1330
1575
λ3
1310
1550
Δ
0.03
0.02
nm
1550
1310
1550
1625
dB
≤0.03
≤0.03
≤0.03
≤0.03
Point Discontinuity [dB]
1310 nm and 1550 nm
≤ 0.05
Optical Return Loss [dB]
Absolute value at all points along the fiber
Attenuation with Bending [dB]
Cable Cutoff Wavelength [nm]
≥ 60
Turns
1
100
100
100
mm
32
50
50
60
≤ 1260
Mode Field Diameter [µm]
1310 nm
9.2±0.4
1550 nm
10.4±0.5
Dispersion [ps/(nm•km)]
1550 nm
1625 nm
Zero Dispersion Wavelength - λo [nm]
Zero Dispersion Slope - So [ps/(nm2•km)]
≤ 18.0
≤ 22.0
1304 to 1324
≤ 0.092
Polarization Mode Dispersion (ps/√km)
Individual fiber
≤ 0.1
Link value
≤ 0.04
Environmental / Attenuation Effects (dB/km)
Temperature Dependence (–60°C to +85°C)
Temperature-Humidity Cycling
(-10°C to +85°C with humidity cycling up to 98% RH)
1310 / 1550 / 1625 nm
≤ 0.05
≤ 0.05
Dry Heat Soak (85±2°C)
≤ 0.05
Water Immersion (23±2°C)
≤ 0.05
Damp Heat Soak (85±2°C, 85% RH, 30 Days)
≤ 0.05
Fiber Curl
≤ 0.05
Deflection for 10 mm overhang (µm)
≤12.4
Corresponding radius of curvature (meters)
≥ 4.0
Minimum Strength (by Proof Test)
Operating Temperature Range
8 | foc low loss fibers
0.69 GPa (100 kpsi)
-60°C to +85°C
SM/MM
SM/MM Fibers
BENDSAFE FIBERS
Available bend radius
BEND RADIUS
BEND RADIUS
BEND RADIUS
10
7.5
BEND RADIUS
15
BEND RADIUS
30
mm
mm
mm
mm
G.657B2,B3
G.657B3
G.652A1,A2
G.652D
BEND RADIUS
40
60
mm
mm
Bendsafe SM Fibers
10
7,5
0.30dB 0.20dB
G.657B3 Plus
0.20dB 0.10dB
0.30dB 0.10dB
0.15dB 0.05dB
0.10dB 0.03dB
G.657B3 (A3)
1.00dB 0.50dB
0.20dB 0.10dB
G.657A2
0.10dB 0.03dB
1.50dB 0.50dB
0.50dB 0.20dB
G.657A1
Max. attenuation for wavelength
1550 nm 1625 nm/both [dB]
15
0.50dB
0.05dB
0.05dB
G.656 - A.B.C.D
0.50dB
G.655 - A.B.C.D
1.00dB 0.25dB
0.03dB
0.03dB
30
0.03dB
0.03dB
Bend radius [mm]
40
G.652D LL
1.00dB 0.25dB
G.652D
60
Bendsafe MM Fibers
10
0.20dB 0.50dB
0.10dB 0.30dB
0.20dB 0.50dB
50/125 OM4
Bend Insensitive
Bending loss for wavelength
850nm 1300nm/both [dB]
15
0.10dB 0.30dB
30
0.20dB 0.50dB
Bend radius [mm]
40
50/125 OM2
50/125 OM3
Bend Insensitive Bend Insensitive
0.10dB 0.30dB
60
7,5
FOC sm/mm bendsafe fibers | 9
FOC
Post-production fiber parameters
Type
Fiber and cables Information
fiber and cables information
Tight buffer vs. Loose tube
Attenuation [dB/km]
1310
1550
850
1300
Low Loss (LL)
0.34
0.22
-
-
Telecom
0.35
0.25
-
-
Standard
0.40
0.30
-
-
Datacom
0.40
0.30
3.50
1.50
2-3mm
900µm
900 µm outer coating
Tube
Gel
Core
125 µm coating
Stripping
Tight buffer
Tight 900 μm fiber
Semi-tight
Semi-tight 900 μm fiber
Easy strip
Easy strip 900 μm fiber
Possibility to remove the 900 μm
coat at the distance of 3-5 cm
Possibility to remove the 900 μm
coat at the distance of 10-20 cm
Possibility to remove the 900 μm
coat at the distance
of 100-150 cm.
10 | foc fiber and cables information
Loose
tube
Tight buffer
250 µm coating
FOC
telecom
fiber identification
Fiber color codes in Loose tube cable design
Other colors available on demand
T-Telecom (according to IEC 60304)
1-12
1
2
3
4
5
6
7
8
9
10
11
12
Code
12
1
2
3
11
Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
13-24
13
14
15
16
17
18
19
20
21
22
23
24
10
4
9
Color
5
8
Code
red
green
blue
white
violet
orange
grey
yellow
brown
pink
natural
7
6
aqua
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
T1-TELecom (according to IEC 60304 Table 3 & ZN-11/TPSA-005-02)
1-12
1
2
3
4
5
6
7
8
9
10
11
12
Code
12
Color
red
blue
white
green
violet
orange
grey
yellow
brown
pink
black
aqua
13-24
13
14
15
16
17
18
19
20
21
22
23
24
2
3
10
4
9
5
8
Code
Color
1
11
red
blue
white
green
violet
orange
grey
yellow
brown
pink
natural
7
6
aqua
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
T2-TELecom (according to EIA 598A)
1-12
1
2
3
4
5
6
7
8
9
10
11
12
12
Code
2
3
11
Color
blue
orange
green
brown
grey
white
red
black
yellow
violet
pink
aqua
13-24
13
14
15
16
17
18
19
20
21
22
23
24
10
4
9
5
8
Code
Color
1
blue
orange
green
brown
grey
white
red
natural
yellow
violet
pink
7
6
aqua
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
FOC fiber color codes | 11
FOC
telecom
fiber in Loose tube color codes
Loose tube color codes in Loose tube cable design
Other colors available on demand
t-telecom - Loose tube in cable (according to iec60304):
Tube
1
2
3
4
5
6
7
8
9
10
11
12
12
Code
Color
1
2
11
3
9
5
10
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
4
8
**In cable with a multi-layer construction color of the tubes will be repeated in second layer
***In case of lower fiber count some tubes can be replaced by fillers
7
6
t1-telecom - Loose tube in cable (according to IEC 60304 Table 3 & ZN-11/TPSA-005-02)
Tube
1
2
3
4
5
6
7
8
9
10
11
12
12
Code
Color
1
2
11
3
9
5
10
red
blue
white
green
violet
orange
grey
yellow
brown
pink
black
aqua
4
8
**In cable with a multi-layer construction color of the tubes will be repeated in second layer
***In case of lower fiber count some tubes can be replaced by fillers
7
6
t2-telecom - Loose tube in cable (according to EIA 598A)
Tube
1
2
3
4
5
6
7
8
9
10
11
12
12
Code
Color
1
2
11
3
9
5
10
blue
orange
green
brown
grey
white
red
black
yellow
violet
pink
aqua
4
8
**In cable with a multi-layer construction color of the tubes will be repeated in second layer
***In case of lower fiber count some tubes can be replaced by fillers
7
6
t3-telecom - Loose tube in cable according to IEC 60304)
Tube
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Code
Color
3
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
luminous
red
patina
green
1
2
3
4
5
6
7
8
9
10
11
12
signal
blue
red
green
white
white
white
white
white
white
white
white
white
white
Code
**In cable with a multi-layer construction color of the tubes will be repeated in second layer
***In case of lower fiber count some tubes can be replaced by fillers
12 | foc fiber color codes
1
4
12
5
6
11
10
E-telecom - Loose tube in cable (according to EIA 598A)
Color
2
13
**In cable with a multi-layer construction color of the tubes will be repeated in second layer
***In case of lower fiber count some tubes can be replaced by fillers
Tube
1
15
14
2
9
8
7
FOC
datacom
fiber color codes
Fiber, buffer and tubes color codes for Datacom cables range
Other colors available on demand
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304)
Fiber in buffer
1-12
1
2
3
4
5
6
7
8
9
10
11
12
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
natural orange
pink
Color*
red
green
blue
yellow
white
grey
brown
violet
brown
dark
green
orange
pink
5
6
7
8
9
10
11
12
Fiber
Buffer
250/900/600 µm
Fiber
Buffer
250 µm
600/900 µm
*Buffer with black mark to identifiy fibers 13-24
Fibers in tubes
1-12
1
2
3
4
24
Code
13
1
23
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
red
green
blue
yellow
white
grey
brown
violet
aqua
dark
green
orange
15
22
16
21
17
20
Code
Color
14
2
19
18
pink
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
Loose tubes in cables
Tube
1
2
3
4
5
6
7
8
9
10
11
12
12
Code
Color
1
2
3
11
red
green
blue
white
violet
orange
grey
yellow
**In cable with a multi-layer construction color of the tubes will be repeated in second layer
***In case of lower fiber count some tubes can be replaced by fillers
brown
pink
black
aqua
10
4
9
5
8
7
6
FOC fiber color codes | 13
FOC
datacom
fiber color codes
Fiber and buffer color codes for datacom cables range
Other colors available on demand
D1-DATACOM (according to IEC 60304 ; TIA/EIA 598-A ; TIA/EIA 598-C /Data Center cables)
Fiber in buffer
1-12
1
2
3
4
5
6
7
8
9
10
11
12
Color
blue
orange
green
brown
grey
white
red
black
yellow
violet
pink
aqua
13-24
13
14
15
16
17
18
19
20
21
22
23
24
Color
blue
orange
green
brown
grey
white
red
natural
yellow
violet
pink
aqua
Color*
blue
orange
green
brown
grey
white
red
dark
green
yellow
violet
pink
aqua
5
6
7
8
9
10
11
12
Fiber
Buffer
250/900/600 µm
Fiber
Code
250 µm
600/900 µm
*Buffer with black mark to identifiy fibers 13-24
Fibers in tubes
1-12
1
2
3
4
24
Code
13
1
23
Color
blue
orange
green
brown
grey
white
red
black
yellow
violet
pink
aqua
13-24
13
14
15
16
17
18
19
20
21
22
23
24
blue
orange
green
brown
grey
white
red
natural
yellow
violet
pink
aqua
14
2
15
22
16
21
17
20
19
18
Code
Color
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
Loose tubes in cables
Tube
1
2
3
4
5
6
7
8
9
10
11
12
12
Code
Color
1
2
3
11
red
green
blue
white
violet
orange
grey
yellow
**In cable with a multi-layer construction color of the tubes will be repeated in second layer
***In case of lower fiber count some tubes can be replaced by fillers
14 | foc fiber color codes
brown
pink
black
aqua
10
4
9
5
8
7
6
FOC
ftth
fiber color codes
Fiber and buffer color codes for FTTH cables range
Other colors available on demand
F-FTTH (according to DIN VDE 0888 & IEC 60304)
1-12
1
2
3
4
5
6
7
8
9
10
11
12
Color
red
blue
green
yellow
violet
white
orange
grey
brown
black
aqua
pink
Color
red
blue
green
yellow
violet
white
orange
grey
brown
black
aqua
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
Color
red
blue
green
yellow
violet
white
orange
grey
brown
black
aqua
pink
Color*
red
blue
green
yellow
violet
white
orange
grey
brown
dark
green
aqua
pink
Fiber
Buffer
250 µm
600/900 µm
Fiber
Code
250 µm
600/900 µm
*Buffer with black mark to identifiy fibers 13-24
FOC fiber color codes | 15
FIBRAIN
COATINGS
Industrial
Oil resistance
Mining
Ship and offshore
Military
Windfarms
Robotic
Datacenter
Telecom
Physical properties of coatings
PE polyethylene
LSOH
PVC polyvinyl chloride
PUR polyurethane
PA polyamide
NBR nitrile rubber
Mechanical resistance
Mechanical resistance
Mechanical resistance
Mechanical resistance
Mechanical resistance
Mechanical resistance
Temperature resistance
Temperature resistance
Temperature resistance
Temperature resistance
Temperature resistance
Temperature resistance
Chemical resistance
Chemical resistance
Chemical resistance
Chemical resistance
Chemical resistance
Chemical resistance
datacom
Furcation tube FSMX 1.6 - 2.8 mm
furcation tube fsmx
Cable structure
1
1.LSOH outer jacket
2.Aramid yarns
3.Central Tube 900 μm
2
3
TRUE
COLORS
Flexible
Easy to terminate
Bendsafe
Configuration
FSMX
Ø nominal
± 5% [mm]
Version
Nominal weight
± 5% [kg/km]
Max. installation
tension
(ε=0.5 %) [N]
Crush
[N/10 cm]
FSMX 1.8
1.8/0.9/0.5
4
100
200
FSMX 2.8
2.8/0.9/0.5
8
350
300
Applications
ÆÆ
Distribution systems cable
ÆÆ
For patchcords and pigtails
ÆÆ
Terminals connection
Jacket colors
Standard
Features
Yellow RAL 1021 White RAL 9010
Blue RAL 5015
Orange RAL 2003
Aqua RAL 6027
Violet RAL 4003
ÆÆ
LSOH with low coefficient of friction
ÆÆ
Aramid yarns
ÆÆ
Central tube 900 µm
Low-radius bending resistance SM
Color codes
30 mm
4
5
6
7
8
9
10
11
12
Fiber
Buffer
Color
900 µm
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
15 mm
G.657A1
7.5 mm
G.657A2
pink
Operating temperature
+100
+70°C
+55°C
-5°C
-10°C
TRANSPORT
3
OPERATION
2
G.652D
INSTALLATION
1
temperature [°C]
1-12
bend radius [mm]
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers
-40°C
-100
datacom furcation tube fsmx | 17
datacom
Buffer BFR 0.6 - 0.9 mm
Buffer bFR
Cable structure
1
1.Outer Tight Buffer Tube
600/900 µm (LSOH)
2.Colored coating on fiber 250 µm
3.Optical Fiber with cladding
125 µm
3
2
TRUE
COLORS
Flexible
Easy to terminate
Semi-tight
Easy-strip
Bendsafe
Configuration
BFR
Version
Fiber qty
Ø nominal
± 5% [mm]
Max. installation
tension ± 5% [N]
1F
1
0.6
4
1F
1
0.9
5
Applications
Crush
[N/10cm]
200
ÆÆ
Distribution systems cable
ÆÆ
For patchcords and pigtails
ÆÆ
Terminals connections
Available outer jacket colors
SM G.652D
Yellow RAL 1021
Features
SM G.657
MM 62.5/125 OM1
A1 / A2 / A3
Blue RAL 5015
White RAL 9010
MM 50/125 OM2
Orange RAL 2003
MM 50/125 OM3
Aqua RAL 6027
MM 50/125 OM4
Violet RAL 4003
Stripping
250 µm fiber
ÆÆ
Variants with different stripability
1
TB00 / TB05 / TB10
+100
+70°C
+55°C
3-5 / 10-20 / 100-150
Color codes
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers
1
2
3
4
5
6
7
8
9
10
11
-5°C
-10°C
12
-40°C
Fiber
-100
Buffer
red
green
blue
yellow
white
18 | datacom buffer bfr cables
grey
brown
violet
aqua
black
orange
pink
TRANSPORT
1F
Stripping - length
in one piece [cm]
OPERATION
1
Stripping
INSTALLATION
1F
Color
ÆÆ
temperature [°C]
Fiber qty
250/600/900 µm
Buffer made of LSOH with low coefficient
of friction
Operating temperature
Version
1-12
ÆÆ
datacom
Simplex SMX 1.2 - 2.8 mm
simplex smx cable
Cable structure
1
1.LSOH outer jacket
2.Aramid yarns
3.Central tight buffer Tube
600/900 μm
2
3
TRUE
COLORS
Flexible
Easy to terminate
Semi-tight
Easy-strip
Bendsafe
Configuration
smx
Version
Ø nominal
± 5% [mm]
Fiber qty
Max. installation
tension
(ε=0.5 %) [N]
Crush
[N/10 cm]
1F
1
1.2
50
200
1F
1
1.6
100
300
1F
1
1.8
150
400
1F
1
2.0
200
500
1F
1
2.8
300
800
Applications
ÆÆ
Distribution systems cable
ÆÆ
For patchcords and pigtails
ÆÆ
Terminals connection
Features
Jacket colors
Standard
ÆÆ
LSOH with low coefficient of friction
ÆÆ
Aramid yarns
ÆÆ
Central tight buffer tube 600/900 µm
ÆÆ
250 µm colored fiber
Low-radius bending resistance SM
Blue RAL 5015
Orange RAL 2003
Aqua RAL 6027
Violet RAL 4003
Color codes
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers
1-12
1
2
3
4
5
6
7
8
9
30 mm
bend radius [mm]
Yellow RAL 1021 White RAL 9010
10
11
G.652D
15 mm
G.657A1
7.5 mm
G.657A2
12
Fiber
Operating temperature
blue
yellow
white
grey
brown
violet
aqua
black
orange
+100
pink
+70°C
+55°C
-5°C
-10°C
TRANSPORT
green
OPERATION
red
temperature [°C]
Color
250/600/900 µm
INSTALLATION
Buffer
-40°C
-100
datacom simplex smx cables | 19
DATACOM
CABLES
TRUE
COLORS
Selection of tubes and cables colors
Other colors available on demand
orange
green
grey
red
violet
yellow
black
brown
pink
aqua
datacom
Duplex Zip Cables 1.6 - 2.8 mm
duplex zip cables
1
Cable structure
1.LSOH outer jacket
2.Aramid yarns
3.Central tight buffer Tube
600/900 µm with colored
fibers 250 µm
2
3
TRUE
COLORS
LSOH
Bendsafe
Easy to terminate
Easy-strip
Semi-tight
Configuration
ZIP
Fiber qty
Dimensions
nominal
± 5% [mm]
Max. installation
tension
(ε=0.5 %) [N]
Crush
[N/10 cm]
2F
2
1.6 x 3.3
200
500
2F
2
1.8 x 3.7
300
500
2F
2
2.0 x 4.1
400
500
2F
2
2.8 x 5.7
600
1000
Applications
ÆÆ
Distribution systems cable
ÆÆ
Patchcords and pigtails
ÆÆ
Terminals connection
Structure and composition
Jacket colors
Standard
MM 50/125 OM2
Orange RAL 2003
250 µm colored fibers
SM low-radius bending resistance
30 mm
15 mm
G.657A1
7.5 mm
G.657A2
Operating temperature
+100
+70°C
+55°C
-5°C
-10°C
TRANSPORT
MM 50/125 OM4
Violet RAL 4003
G.652D
OPERATION
MM 50/125 OM3
Aqua RAL 6027
MM 62,5/125 OM1
Blue RAL 5015
Aramid yarns
ÆÆ
bend radius [mm]
SM G.657
A1 / A2 / A3
White RAL 9010
LSOH with low coefficient of friction
ÆÆ
temperature [°C]
SM G.652D
Yellow RAL 1021
ÆÆ
INSTALLATION
Version
-40°C
-100
datacom DUPLEX ZIP CABLES | 21
datacom
LDC
LDC
Cable structure
1
3
2
1.Outer jacket LSOH UV Stabilized
2.Tight Tubes 900 µm (LSOH)
with colored fibers 250 µm
3.Aramid yarns
TRUE
COLORS
LSOH
Bendsafe
Easy to terminate
Semi-tight
Easy-strip
Datacenter
Configuration
LDC
Version
Tight buffers
[pcs]
Ø
± 5% [mm]
Nominal
weight LSOH
± 5% [kg/km]
2F
2
4.5
21
4F
4
5.0
26
6F
6
5.5
30
8F
8
5.5
35
10F
10
6.5
40
12F
12
6.5
45
16F
16
7.0
50
24F
24
8.0
65
Max. tensile load [N]
installation
operation
500
Crush
[N/10 cm]
125
500
700
175
1000
250
Applications
ÆÆ
Indoor/outdoor installations
ÆÆ
Distribution networks in multifamily buildings
ÆÆ
FTTD Connections
ÆÆ
Distribution systems
ÆÆ
Fully dielectric
ÆÆ
LAN and FTTX network
ÆÆ
ODF connection
ÆÆ
Datacenter distribution
Features
Jacket colors
ÆÆ
Compact design
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers
ÆÆ
Lightweight
ÆÆ
Flexible
ÆÆ
Easy to strip
ÆÆ
Fully dielectric
ÆÆ
Reduced diameter
ÆÆ
Direct connectorization
1-12
1
2
3
4
5
6
7
8
9
10
11
12
Fiber
Buffer
Color
250/600/900
µm
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
Operating temperature
+100
Fiber
+70°C
Code
yellow
white
grey
brown
violet
aqua
natural orange
pink
Color*
red
green
blue
yellow
white
grey
brown
violet
brown
dark
green
pink
600/900 µm
*Buffer with black mark to identifiy fibers 13-24
orange
-5°C
-10°C
-40°C
-100
22 | datacom LDC
TRANSPORT
blue
OPERATION
green
INSTALLATION
red
250 µm
temperature [°C]
+55°C
Color
datacom
LBR
LBR
Cable structure
1.Outer jacket LSOH
UV Stabilized
2.Subcables 1.8 mm
with tight tubes
900 µm (LSOH) with
250 µm colored
fibers
1
2
3
3.Aramid yarns
4.Central FRP strength
member
5.Ripcord
1
2
3
4
TRUE
COLORS
LSOH
Bendsafe
Easy to terminate
Semi-tight
Easy-strip
5
Datacenter
Configuration
LBR
Version
Fiber qty
Ø
± 5%
[mm]
Nominal weight
LSOH ± 5%
[kg/km]
installation
operation
4F
4
6.5
48
750
250
6F
6
7.5
63
1200
400
8F
8
8.7
85
1500
12F
12
10.9
131
Max. tensile load [N]
1500
Crush
[N/10 cm]
Applications
ÆÆ
Indoor/outdoor installations
ÆÆ
Distribution networks in multifamily buildings
ÆÆ
FTTD Connections
ÆÆ
Distribution systems
500
ÆÆ
Fully dielectric
500
ÆÆ
LAN and FTTX network
ÆÆ
ODF connection
ÆÆ
Datacenter distribution
16F
16
11.3
119
1700
550
18F
18
11.3
131
1700
550
24F
24
13.0
179
2000
660
2000
Features
Standard jacket colors:
PE Black RAL9005
LSOH Grey RAL7022
ÆÆ
Simplex sub cable up to 24 fibers
ÆÆ
Fully dielectric cable
ÆÆ
Aramid yarns as tensile elements
ÆÆ
UV Resistant and LSOH flame retardant outer
jacket
LSOH Light Grey
RAL7037
Operating temperature
+100
Outer jacket color options:
+70°C
SM G.652D
RAL 1021
SM G657A1, A2, A3
RAL 9010
MM 50/125 OM2
RAL 2003
MM 50/125 OM3
RAL6027
MM 50/125 OM4
RAL4003
TRANSPORT
OPERATION
-5°C
INSTALLATION
temperature [°C]
+55°C
-20°C
-40°C
-100
datacom LBR | 23
datacom
DC-PRIM
DC-PRIM
Cable structure
1
1.LSOH outer jacket
2.Aramid yarns
3.250 µm optical fibers
2
3
TRUE
COLORS
LSOH
Bendsafe
Easy to terminate
Datacenter
Configuration
DC-PRIM
No. of fibers
12
24
Outer diameter [mm] (±5%)
3.0
3.5
Max tensile load (ε=0.5%) [N]
350
350
8
9
Weight [kg/km] (±10%)
Crush [N/10 cm]
Applications
350
Min. bend radius [mm]
45 (depends on fiber type)
60 (depends on fiber type)
ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
Customer connection, fully dielectric cable
ÆÆ
MTP/MPO termination cable
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
Inside house OLT connection
ÆÆ
Data Center connections cable
Outer jacket color options:
Features
Ivory
RAL 1015
Yellow
RAL 1021
White
RAL 9010
Blue
RAL 5015
Orange
RAL 2003
Green
RAL 6018
Aqua
RAL 6027
Violet
RAL 4003
ÆÆ
Aramid strength element
ÆÆ
250 µm optical fibers (12-24)
ÆÆ
LSOH outer jacket
Available colors
Operating temperature
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
1
2
3
4
5
6
7
8
9
10
11
+100
12
+70°C
Fiber
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
Fiber
Code
Color*
red
green
blue
*Fiber with black mark to identify fibers 13-24
24 | datacom DC-PRIM
yellow
white
grey
brown
violet
brown
dark
green
orange
pink
-5°C
-10°C
-40°C
-100
TRANSPORT
green
OPERATION
red
temperature [°C]
+55°C
Color
INSTALLATION
1-12
datacom
DC-DRIM
DC-DRIM
1
1
Cable structure
2
2
1.LSOH outer jacket
2.Aramid yarns
3.LSOH inner jacket
4.Aramid yarns
5.250 µm optical fibers
3
3
5
4
TRUE
COLORS
LSOH
Bendsafe
Easy to terminate
Datacenter
Configuration
DC-DRIM
No. of fibers
12
24
Outer diameter [mm] (±5%)
4.5
5.0
Max tensile load (ε=0.5%) [N]
600
600
8
9
Weight [kg/km] (±10%)
Crush [N/10cm]
Applications
300
Min. bend radius [mm]
65 (depends on fiber type)
75 (depends on fiber type)
ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
Customer connection, fully dielectric cable
ÆÆ
MTP/MPO termination cable
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
Inside house OLT connection
ÆÆ
Data Center connections cable
Outer jacket color options:
Features
Ivory
RAL 1015
Yellow
RAL 1021
White
RAL 9010
Blue
RAL 5015
Orange
RAL 2003
Green
RAL 6018
Aqua
RAL 6027
Violet
RAL 4003
ÆÆ
Aramid strength element in two layers
ÆÆ
250 µm optical fibers (12-24)
ÆÆ
LSOH double jacket
Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
1
2
3
4
5
6
7
Operating temperature
8
9
10
11
12
+100
+70°C
Fiber
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
Fiber
Code
Color*
red
green
blue
*Fiber with black mark to identify fibers 13-24
yellow
white
grey
brown
violet
brown
dark
green
orange
+55°C
-5°C
-10°C
TRANSPORT
green
OPERATION
red
temperature [°C]
Color
INSTALLATION
1-12
pink
-40°C
-100
datacom DC-DRIM | 25
datacom
EXO-CU Cables Loose tube
exo-cU cables
1
Cable structure
Datacom
ETR
Compact design
1.LSOH outer jacket
2.Central Loose tube (PBT)
with colored fibers in filling
compound
3.Optical fibers
4.Fiberglass yarns
5.Ripcord
Basic Rodent
Protection
LSOH
LSOH Jacket
Exo-CU
Version
Fiber qty
Ø ± 5%
[mm]
Max. tensile load [N]
installation
1T x 2F
2
6.4
47
1T x 4F
4
6.8
48
1T x 6F
6
6.8
51
(ε=0,33%)
1T x 8F
8
6.8
51
1600
1T x 12F
12
6.8
52
1T x 24F
24
7.1
62
4
5
Configuration
Nominal weight
LSOH ± 5%
[kg/km]
3
2
Crush
[N/10 cm]
operation
1100
300
700
Applications
ÆÆ
Fully dielectric cable
ÆÆ
Basic rodent protection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
(ε=0,5%)
Features
Available colors
ÆÆ
Fiberglass strength element
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound
ÆÆ
Loose tube (PBT)
ÆÆ
Fiberglass as water absorbent and strain relief
element
ÆÆ
LSOH outer jacket
1
2
3
4
5
6
7
8
9
10
11
12
Code
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
aqua
dark
green
Code
green
blue
yellow
white
grey
brown
violet
orange
pink
+100
+70°C
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
Fiber identification
Jacket colors
Standard
24
13
1
23
15
16
21
17
20
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
Optional
SM G.652D RAL 1021
SM G657 A1, A2, A3
RAL 9010
MM 50/1025 OM2
RAL 2003
26 | datacom exo-CU cables
MM 50/1025 OM3
RAL6027
MM 50/1025 OM4
RAL4003
-5°C
14
2
22
PE Black RAL 9005
temperature [°C]
+55°C
19
18
-50°C
-100
TRANSPORT
red
OPERATION
Color
Operating temperature
INSTALLATION
1-12
datacom
EXO-C0 Cables Loose tube
exo-c0 cables
1
Cable structure
Datacom
ETR
Compact design
1.LSOH outer jacket
2.Central Loose tube (PBT)
with colored fibers in filling
compound
3.Optical fibers
4.Fiberglass yarns
5.Ripcord
Basic Rodent
Protection
LSOH
LSOH Jacket
Exo-C0
Fiber qty
1T x 2F
2
6.8
52
1T x 4F
4
7.2
53
1Tx 6F
6
7.2
57
1T x 8F
8
7.2
58
1T x 12F
12
7.2
58
1T x 16F
16
7.4
62
1T x 24F
24
7.4
62
Max. tensile load [N]
installation
Crush
[N/10 cm]
operation
1300
(ε=0,33%)
500
1900
ÆÆ
Fully dielectric cable
ÆÆ
Basic rodent protection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
1500
(ε=0,5%)
Features
Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
1
2
3
4
5
6
7
8
9
10
11
12
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
aqua
dark
green
Code
ÆÆ
Fiberglass strength element
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound
ÆÆ
Loose tube (PBT)
ÆÆ
Fiberglass as water absorbent and strain relief
element
ÆÆ
LSOH outer jacket
Operating temperature
+100
Code
green
blue
yellow
white
grey
brown
violet
orange
pink
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
Fiber identification
Jacket colors
+55°C
-5°C
TRANSPORT
red
temperature [°C]
Color
+70°C
OPERATION
1-12
Applications
INSTALLATION
Version
Ø ± 5%
[mm]
4
5
Configuration
Nominal weight
LSOH ± 5%
[kg/km]
3
2
Standard
24
13
1
23
14
2
22
16
21
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
-100
17
20
PE Black RAL 9005
-50°C
15
19
18
Optional
SM G.652D RAL 1021
SM G657 A1, A2, A3
RAL 9010
MM 50/1025 OM2
RAL 2003
MM 50/1025 OM3
RAL6027
MM 50/1025 OM4
RAL4003
datacom exo-c0 Cables | 27
datacom
EXO-CI Cables Loose tube
exo-cI cables
1
Cable structure
Datacom
ETR
Compact design
1.LSOH outer jacket
2.Central Loose tube (PBT)
with colored fibers in filling
compound
3.Optical fibers
4.Fiberglass yarns
5.Ripcord
Basic Rodent
Protection
LSOH
LSOH Jacket
Exo-CI
Fiber qty
1T x 2F
2
7.1
52
1T x 4F
4
7.4
53
1Tx 6F
6
7.4
57
1T x 8F
8
7.4
58
1T x 12F
12
7.4
58
1T x 16F
16
7.7
62
1T x 24F
24
7.7
62
Max. tensile load [N]
installation
Crush
[N/10 cm]
operation
1800
(ε=0,33%)
1000
2700
2
3
4
5
Fully dielectric cable
ÆÆ
Basic rodent protection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
1500
Features
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
1
ÆÆ
(ε=0,5%)
Available colors
6
7
8
9
10
11
12
Code
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
ÆÆ
Fiberglass strength element
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound
ÆÆ
Loose tube (PBT)
ÆÆ
Fiberglass as water absorbent and strain relief
element
ÆÆ
LSOH outer jacket
Operating temperature
Code
green
blue
yellow
white
grey
brown
violet
dark
green
aqua
orange
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
Fiber identification
Jacket colors
+70°C
pink
+55°C
-5°C
Standard
24
13
1
23
14
2
15
22
21
17
20
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
PE Black RAL 9005
Optional
SM G.652D RAL 1021
SM G657 A1, A2, A3
RAL 9010
19
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
MM 50/1025 OM2
RAL 2003
28 | datacom exo-CI CABLES
MM 50/1025 OM3
RAL6027
MM 50/1025 OM4
RAL4003
-50°C
16
18
-100
TRANSPORT
red
temperature [°C]
Color
+100
OPERATION
1-12
Applications
INSTALLATION
Version
Ø ± 5%
[mm]
4
5
Configuration
Nominal weight
LSOH ± 5%
[kg/km]
3
2
datacom
EXO-GU Cables Loose tube
exo-GU cables
1
Cable structure
Datacom
Compact design
1.LSOH outer jacket
2.Central Loose tube (PBT)
with colored fibers in filling
compound
3.Optical fibers
4.Fiberglass yarns
5.Ripcord
Basic Rodent
Protection
LSOH
LSOH Jacket
Exo-GU
Version
Fibers
per tube
Fiber qty
Ø ± 5%
[mm]
1T x 2F
2
2
5.8
34
1T x 4F
4
4
5.8
34
1T x 6F
6
6
5.8
35
1T x 8F
8
8
5.8
35
1T x 12F
12
12
5.8
35
1T x 16F
16
16
5.8
35
1T x 18F
18
18
5.8
36
1T x 24F
24
24
5.8
36
4
5
Configuration
Nominal weight
LSOH ± 5%
[kg/km]
3
2
Max. tensile load [N]
installation
Crush
[N/10 cm]
operation
1200
(ε=0,33%)
400
1500
Applications
ÆÆ
Fully dielectric cable
ÆÆ
Basic rodent protection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
1500
(ε=0,5%)
Features
Available colors
ÆÆ
Central Loose tube (PBT) with filling compound
ÆÆ
Optical fibers
ÆÆ
Fiberglass as water absorbent and strain relief
element
ÆÆ
LSOH outer jacket
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
4
5
6
7
8
9
10
11
12
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
red
green
blue
yellow
white
grey
brown
violet
aqua
dark
green
orange
pink
Code
Code
Color
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm;
Fiber identification
Jacket colors
Standard
24
23
+55°C
-5°C
-20°C
15
16
21
17
20
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
+70°C
14
2
22
PE Black RAL 9005
+100
-100
13
1
Operating temperature
TRANSPORT
3
OPERATION
2
INSTALLATION
1
temperature [°C]
1-12
19
18
Optional
SM G.652D RAL 1021
SM G657 A1, A2, A3
RAL 9010
MM 50/1025 OM2
RAL 2003
MM 50/1025 OM3
RAL 6027
MM 50/1025 OM4
RAL 4003
datacom exo-GU Cables | 29
datacom
EXO-G0 Cables Loose tube
exo-G0 cables
1
Cable structure
Datacom
Compact design
1.LSOH outer jacket
2.Central Loose tube (PBT)
with colored fibers in filling
compound
3.Optical fibers
4.Fiberglass yarns
5.Ripcord
Basic Rodent
Protection
LSOH
LSOH Jacket
Exo-G0
Version
1T x 2F
Fiber
qty
2
2
Ø ± 5%
[mm]
5.9
Applications
Max. tensile load [N]
Nominal
weight LSOH
± 5%
[kg/km]
Crush
[N/10 cm]
ÆÆ
Fully dielectric cable
ÆÆ
Basic rodent protection
ÆÆ
LAN and FTTX networks
37
ÆÆ
Distribution network
ÆÆ
ODF connections
1T x 4F
4
4
5.9
37
1T x 6F
6
6
5.9
37
1T x 8F
8
8
5.9
37
1T x 12F
12
12
5.9
38
1T x 16F
16
16
5.9
38
1T x 18F
18
18
5.9
38
1T x 24F
24
24
5.9
40
4
5
Configuration
Fibers
per
tube
3
2
installation
operation
1500
(ε=0,33%)
500
2200
1500
Features
(ε=0,5%)
Available colors
ÆÆ
Central Loose tube (PBT) with filling compound
ÆÆ
Optical fibers
ÆÆ
Fiberglass as water absorbent and strain relief
element
ÆÆ
LSOH outer jacket
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
4
5
6
7
8
9
10
11
12
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
red
green
blue
yellow
white
grey
brown
violet
aqua
dark
green
orange
pink
Code
Code
Color
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm;
Fiber identification
Jacket colors
Standard
24
23
14
2
15
22
16
21
17
20
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
Optional
SM G.652D RAL 1021
SM G657 A1, A2, A3
RAL 9010
MM 50/1025 OM2
RAL 2003
30 | datacom exo-g0 CABLES
MM 50/1025 OM3
RAL 6027
MM 50/1025 OM4
RAL 4003
19
+100
+70°C
+55°C
-5°C
-20°C
-100
13
1
Operating temperature
18
TRANSPORT
3
OPERATION
2
INSTALLATION
1
temperature [°C]
1-12
datacom
EXO-GI Cables Loose tube
exo-GI cables
1
Cable structure
Datacom
Compact design
1.LSOH outer jacket
2.Central Loose tube (PBT)
with colored fibers in filling
compound
3.Optical fibers
4.Fiberglass yarns
5.Ripcord
Basic Rodent
Protection
LSOH
3
2
5
LSOH Jacket
Configuration
Exo-GI
Version
Fiber qty
Ø ± 5%
[mm]
Fibers per tube
4
Applications
Max. tensile load
[N]
Nominal
weight LSOH
± 5%
[kg/km]
installation
Crush
[N/10 cm]
operation
ÆÆ
Fully dielectric cable
ÆÆ
Basic rodent protection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
1T x 2F
2
2
6.1
38
1T x 4F
4
4
6.1
38
1T x 6F
6
6
6.1
39
1T x 8F
8
8
6.1
40
1T x 12F
12
12
6.1
40
1T x 16F
16
16
6.1
41
1T x 18F
18
18
6.1
42
ÆÆ
Central Loose tube (PBT) with filling compound
42
ÆÆ
Optical fibers
ÆÆ
Fiberglass as water absorbent and strain relief
element
ÆÆ
LSOH outer jacket
1T x 24F
24
24
6.1
1800
(ε=0,33%)
600
2700
1500
(ε=0,5%)
Features
Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
4
5
6
7
8
9
10
11
12
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
red
green
blue
yellow
white
grey
brown
violet
aqua
dark
green
orange
pink
Code
Code
Color
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm;
Fiber identification
Jacket colors
Standard
24
23
+70°C
+55°C
-5°C
-20°C
14
2
15
22
16
21
17
20
PE Black RAL 9005
+100
-100
13
1
Operating temperature
TRANSPORT
3
OPERATION
2
INSTALLATION
1
temperature [°C]
1-12
19
18
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
Optional
SM G.652D RAL 1021
SM G657 A1, A2, A3
RAL 9010
MM 50/1025 OM2
RAL 2003
MM 50/1025 OM3
RAL 6027
MM 50/1025 OM4
RAL 4003
datacom exo-GI Cables | 31
datacom
DATACOM BDC-MSA
bdc-MSA
1
Cable structure
6.Loose tubes (PBT)
with colored fibers
in filling gel
7.Fillers
8.Ripcord
1.LSOH outer jacket
2.Water-blocking
fiberglass yarns
3.Water blocking yarns
4.PET tape
5.Central strength
member (FRP)
Datacom
ETR
Compact design
2
4
5
3
6
7
8
Basic Rodent
Protection Datacenter
LSOH
Configuration
BDC-msa
Fibers
per
tube
Total
elements
Ø
± 5%
[mm]
Active
tubes
installation
Crush
[N/10 cm]
operation
1T x 12F
12
12
6
1
8.2
50
65
1500
550
2T x 6F
12
6
6
2
8.2
50
65
1550
780
2T x 12F
24
12
6
2
8.2
51
65
1500
550
4T x 6F
24
6
6
4
8.2
51
66
1550
780
3T x 12F
36
12
6
3
8.2
52
67
1500
550
6T x 6F
36
6
6
6
8.2
53
68
1550
780
4T x 12F
48
12
6
4
8.2
53
68
1500
550
5T x 12F
60
12
6
5
8.2
54
69
1500
550
6T x 12F
72
12
6
6
8.2
54
69
1500
550
8T x 12F
96
12
8
8
9.3
71
86
1620
750
12T x 12F
144
12
12
12
11.5
104
126
1620
850
ÆÆ
Fully dielectric cable
ÆÆ
Basic rodent protection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
Features
1500
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound (PBT Ø 1.8 mm)
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Fiberglass as water absorbent and strain relief
element
ÆÆ
UV stabilized LSOH jacket
Operating temperature
Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
2
3
4
5
6
7
8
9
10
11
12
Code
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Tubes
Tube
1
2
3
4
5
6
7
8
9
10
11
12
Code
Color
+70°C
+55°C
-5°C
-20°C
-40°C
red
green
blue
yellow
white
*In case of lower fiber count some tubes can be replaced by fillers.
32 | datacom bdc-MSA cables
grey
brown
violet
aqua
black
orange
pink
-100
TRANSPORT
1
temperature [°C]
1-12
+100
OPERATION
Fibers
INSTALLATION
Version
Applications
Max. tensile
load [N]
Nominal
weight
LSOH
±5%
[kg/km]
Nominal
weight PE
±5%
[kg/km]
FTTH
Cables
VC-D20/VC-D30
VC-D40/VC-DCY
SOLID CONNECTION TO YOUR PROVIDER
BEND
RESISTANCE
EASY TO
TERMINATE
LSOH
SAFE COVER
SMALL
DIMENSIONS
SAFE
DAILY USE
ftth
FTTH VC-D20
VC-d20
1
Cable structure
2
3
1.LSOH outer jacket
2.Aramid yarns
3.900 µm central semi tight buffer tube
with 250 µm colored fiber
Last mile
connection outdoor
LSOH
Flexible
Easy to terminate
Bendsafe
FTTH
Configuration
VC-d20
No. of fibers
Applications
1F 900 µm
ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
Customer connection
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
10-60 mm*
ÆÆ
LAN and FTTX networks
300
ÆÆ
Distribution network
ÆÆ
ODF connections
ÆÆ
Inside house OLT connection
Outer diam [mm]
2.0
Tensile load perm/inst. [N]
75/200
Weight [kg/km]
7
Min. bend radius [mm]
Crush [N/10 cm]
*Depends on fiber type
Bend radius/maximum attenuation
Features
ÆÆ
Aramid strength element
ÆÆ
Optical 900 µm semi tight tube
ÆÆ
LSOH outer jacket
Operating temperature
+100
+70°C
-5°C
TRANSPORT
+55°C
OPERATION
0.30dB 0.20dB
G.657B3 Plus
0.20dB 0.10dB
0.30dB 0.10dB
0.15dB 0.05dB
G.657B3 (A3)
0.10dB 0.03dB
1.00dB 0.50dB
0.20dB 0.10dB
0.10dB 0.03dB
1.50dB 0.50dB
0.50dB 0.20dB
1.00dB 0.25dB
0.03dB
0.03dB
G.657A2
INSTALLATION
7,5
G.657A1
temperature [°C]
10
G.652D LL
Max. attenuation for wavelength
1550 nm 1625nm/both [dB]
15
0.03dB
30
0.03dB
Bend radius [mm]
40
1.00dB 0.25dB
G.652D
60
-20°C
-40°C
-100
ftth VC-D20 cables
| 35
ftth
FTTH VC-D30
VC-d30
1
2
3
Cable structure
1.LSOH outer jacket
2.Aramid yarns
3.900 µm central semi tight buffer tube
with 250 µm colored fiber
Last mile
connection outdoor
LSOH
Flexible
Easy to terminate
Bendsafe
FTTH
Configuration
VC-d30
No. of fibers
Applications
1F 900 µm
Outer diam [mm]
3.0
Tensile load perm/inst. [N]
60/170
Weight [kg/km]
8
Min. bend radius [mm]
ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
Customer connection
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
10-60 mm*
ÆÆ
LAN and FTTX networks
500
ÆÆ
Distribution network
ÆÆ
ODF connections
ÆÆ
Inside house OLT connection
Crush [N/10 cm]
*Depends on fiber type
Bend radius/maximum attenuation
10
7,5
Features
0.30dB 0.20dB
G.657B3 Plus
0.20dB 0.10dB
0.30dB 0.10dB
0.15dB 0.05dB
G.657B3 (A3)
0.10dB 0.03dB
1.00dB 0.50dB
0.20dB 0.10dB
0.10dB 0.03dB
1.50dB 0.50dB
G.657A2
Max. attenuation for wavelength
1550 nm 1625nm/both [dB]
15
G.657A1
0.50dB 0.20dB
1.00dB 0.25dB
0.03dB
G.652D LL
0.03dB
0.03dB
30
0.03dB
Bend radius [mm]
40
1.00dB 0.25dB
G.652D
60
ÆÆ
Aramid strength element
ÆÆ
Optical 900 µm semi tight tube
ÆÆ
LSOH outer jacket
Operating temperature
+100
-20°C
-40°C
-100
36 | ftth VC-D30 cables
TRANSPORT
-5°C
OPERATION
+55°C
INSTALLATION
temperature [°C]
+70°C
ftth
FTTH VC-D40
VC-d40
1
Cable structure
1.LSOH outer jacket
2.Aramid yarns
3.900 µm central semi tight buffer tube
with 250 µm colored fiber
Last mile
connection outdoor
LSOH
Flexible
Easy to terminate
2
3
Bendsafe
FTTH
Configuration
VC-d40
No. of fibers
Applications
1-2F 900 µm
ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
Customer connection
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
10-60 mm*
ÆÆ
LAN and FTTX networks
1000
ÆÆ
Distribution network
ÆÆ
ODF connections
ÆÆ
Inside house OLT connection
Outer diam [mm]
4.0
Tensile load perm/inst. [N]
150/400
Weight [kg/km]
15
Min. bend radius [mm]
Crush [N/10 cm]
*Depends on fiber type
Bend radius/maximum attenuation
Features
ÆÆ
Aramid strength element
ÆÆ
Optical 900 µm semi tight tube
ÆÆ
LSOH outer jacket
Operating temperature
+100
+70°C
-5°C
TRANSPORT
+55°C
OPERATION
0.30dB 0.20dB
G.657B3 Plus
0.20dB 0.10dB
0.30dB 0.10dB
0.15dB 0.05dB
G.657B3 (A3)
0.10dB 0.03dB
1.00dB 0.50dB
0.20dB 0.10dB
0.10dB 0.03dB
1.50dB 0.50dB
0.50dB 0.20dB
1.00dB 0.25dB
0.03dB
0.03dB
G.657A2
INSTALLATION
7,5
G.657A1
temperature [°C]
10
G.652D LL
Max. attenuation for wavelength
1550 nm 1625nm/both [dB]
15
0.03dB
30
0.03dB
Bend radius [mm]
40
1.00dB 0.25dB
G.652D
60
-20°C
-40°C
-100
ftth VC-D40 cables
| 37
ftth
FTTH VC-DCY
VC-dcy
3
2
Cable structure
1.LSOH outer jacket
(white/ivory/black)
2.FRP rod
3.250 µm optical fibers
Last mile
connection outdoor
LSOH
Flexible
Easy to terminate
Bendsafe
FTTH
Hi-crush
Configuration
VC-dCY
No. of fibers
Applications
1-4F 900 µm
Outer diam [mm]
ÆÆ
FTTH drop cable reinforced with FRP rods
ÆÆ
Customer connection
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
15-40 mm*
ÆÆ
LAN and FTTX networks
1000
ÆÆ
Distribution network
ÆÆ
ODF connections
ÆÆ
Inside house OLT connection
2.0x3.1 ±0.1
Tensile load perm/inst. [N]
50/100
Weight [kg/km]
8.3
Min. bend radius [mm]
Crush [N/10 cm]
*Depends on fiber type
Bend radius/maximum attenuation
10
7,5
0.30dB 0.20dB
G.657B3 Plus
0.20dB 0.10dB
0.30dB 0.10dB
0.15dB 0.05dB
G.657B3 (A3)
0.10dB 0.03dB
1.00dB 0.50dB
0.20dB 0.10dB
0.10dB 0.03dB
1.50dB 0.50dB
G.657A2
Max. attenuation for wavelength
1550 nm 1625nm/both [dB]
15
G.657A1
0.50dB 0.20dB
1.00dB 0.25dB
0.03dB
G.652D LL
0.03dB
0.03dB
30
0.03dB
Bend radius [mm]
40
1.00dB 0.25dB
G.652D
60
Features
ÆÆ
FRP rods
ÆÆ
250 µm optical fibers
ÆÆ
LSOH outer jacket
Operating temperature
+100
-30°C
-100
38 | ftth VC-Dcy cables
TRANSPORT
OPERATION
INSTALLATION
temperature [°C]
+70°C
+55°C
1
ftth
FTTH VC-D30 RESIBENDTM
VC-d30 resibendTM
1
3
Cable structure
2
1.LSOH outer jacket
2.Aramid yarns
3.900 µm central semi tight buffer tube
with 250 µm colored fiber
ResibendTM
Last mile
connection outdoor
LSOH
Flexible
Easy to terminate
FTTH
Bendsafe
Configuration
VC-d30 resibendTM
No. of fibers
Applications
1F 900 µm
Outer diam [mm]
3.0
Tensile load perm/inst. [N]
60/170
ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
For customer connection
ÆÆ
Fully dielectric cable
Weight [kg/km]
8
Min. bend radius [mm]
ÆÆ
Last mile connection
10
ÆÆ
LAN and FTTX networks
Crush [N/10 cm]
500
ÆÆ
Distribution network
ÆÆ
ODF connections
ÆÆ
Inside house OLT connection
Bend radius/maximum attenuation
G.657B3 (A3)
Fiber bending radius [mm]
5
Max. change in attenuation [dB]
Features
1550 nm
1625 nm
0.10
0.25
ÆÆ
Aramid yarns as strain relief
ÆÆ
Optical fiber in 900 µm semi tight buffer
ÆÆ
LSOH outer jacket (various colors available)
ÆÆ
G.657B3 A3 optical fibers
7.5
0.05
0.15
10
0.03
0.10
Operating temperature
+100
-20°C
-40°C
-100
40 | ftth VC-D30 resibendTM cables
TRANSPORT
-5°C
OPERATION
+55°C
INSTALLATION
temperature [°C]
+70°C
ftth
FTTH VC-D30 RESIBEND PLUSTM
VC-d30 resibend plusTM
1
3
Cable structure
2
1.LSOH outer jacket
2.Aramid yarns
3.900 µm central semi tight buffer tube
with 250 µm colored fiber
Resibend PlusTM
Last mile
connection outdoor
LSOH
Flexible
Easy to terminate
FTTH
Bendsafe
Configuration
VC-d30 resibend plusTM
No. of fibers
Applications
1F 900 µm
Outer diam [mm]
3.0
Tensile load perm/inst. [N]
60/170
Weight [kg/km]
8
Min. bend radius [mm]
7.5
Crush [N/10 cm]
500
Bend radius/maximum attenuation
ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
For customer connection
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
ÆÆ
Inside house OLT connection
G.657B3 Plus
Fiber bending radius [mm]
Max. change in attenuation [dB]
Features
1550 nm
1625 nm
2.5
0.20
0.30
ÆÆ
Aramid yarns as strain relief
5
0.10
0.20
ÆÆ
Optical fiber in 900 µm semi tight buffer
ÆÆ
LSOH outer jacket (various colors available)
ÆÆ
G.657B3 optical fibers
Operating temperature
+100
TRANSPORT
-5°C
OPERATION
+55°C
INSTALLATION
temperature [°C]
+70°C
-20°C
-40°C
-100
ftth VC-D30 resibend plusTM cables
| 41
ftth
FTTH VC-D30 Easy Section Module
VC-d30 Easy Section Module
1
3
Cable structure
2
1.LSOH outer jacket
2.Aramid yarns
3.Optical fibers (250 µm) in Easy Section
Module
Last mile
connection outdoor
Last mile
connection outdoor
Easy Section
Module
Bendsafe
LSOH
Easy to terminate
Flexible
Bendsafe
FTTH
Configuration
VC-D30 Easy Section Module
Active
modules
2F
2
2
1
1
3.1
9
4F
4
4
1
1
3.1
9
allowed
170
static
60
Applications
Crush
[N/10 cm]
1000
Bend radius/maximum attenuation
7,5
0.30dB 0.20dB
G.657B3 Plus
0.20dB 0.10dB
0.30dB 0.10dB
0.15dB 0.05dB
G.657B3 (A3)
0.10dB 0.03dB
1.00dB 0.50dB
0.20dB 0.10dB
G.657A2
0.10dB 0.03dB
1.50dB 0.50dB
0.50dB 0.20dB
1.00dB 0.25dB
0.03dB
0.03dB
G.657A1
Optical cable with aramid yarns reinforcement
ÆÆ
For customer connection
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
ÆÆ
Inside house OLT connection
Features
ÆÆ
Aramid strength element
ÆÆ
Optical fibers (up to 4 pcs) inside 900µm
FlexModule
ÆÆ
LSOH outer jacket
Operating temperature
+100
+70°C
temperature [°C]
10
G.652D LL
Max. attenuation for wavelength
1550 nm 1625nm/both [dB]
15
0.03dB
30
0.03dB
Bend radius [mm]
40
1.00dB 0.25dB
G.652D
60
ÆÆ
+55°C
-5°C
TRANSPORT
Total
elements
Max. tension
[N]
OPERATION
Fibers
Nominal
weight
±5%
[kg/km]
Ø
± 5%
[mm]
INSTALLATION
Version
Fibers
per
module
-20°C
-40°C
-100
ftth Vc-d30 Easy Section Module
| 43
ftth
FTTH VC-D40 Easy Section Module
VC-d40 Easy Section Module
1
3
Cable structure
2
1.LSOH outer jacket
2.Aramid yarns
3.Optical fibers (250 µm) in Easy Section
Module
Easy Section
Module
Last mile
connection outdoor
LSOH
Easy to terminate
Flexible
Bendsafe
FTTH
Configuration
VC-D40 Easy Section Module
Version
Fibers
Fibers
per
module
Total
elements
Active
modules
Nominal
weight
±5%
[kg/km]
Ø
± 5%
[mm]
2F
2
2
1
1
4.1
15
4F
4
4
1
1
4.1
15
Max. tension
[N]
allowed
420
static
150
Applications
Crush
[N/10 cm]
1000
Bend radius/maximum attenuation
10
7,5
0.30dB 0.20dB
G.657B3 Plus
0.20dB 0.10dB
0.30dB 0.10dB
0.15dB 0.05dB
0.10dB 0.03dB
1.00dB 0.50dB
G.657B3 (A3)
Max. attenuation for wavelength
1550 nm 1625nm/both [dB]
15
0.20dB 0.10dB
G.657A2
0.10dB 0.03dB
1.50dB 0.50dB
G.657A1
0.50dB 0.20dB
1.00dB 0.25dB
0.03dB
G.652D LL
0.03dB
30
0.03dB
Bend radius [mm]
40
0.03dB
60
1.00dB 0.25dB
G.652D
ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
For customer connection
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
ODF connections
ÆÆ
Inside house OLT connection
Features
ÆÆ
Aramid strength element
ÆÆ
Optical fibers (up to 4 pcs) inside 900µm
FlexModule
ÆÆ
LSOH outer jacket
Operating temperature
+100
-20°C
-40°C
-100
44 | ftth VC-D40 Easy Section Module
TRANSPORT
-5°C
OPERATION
+55°C
INSTALLATION
temperature [°C]
+70°C
ftth
DC-PRIM
DC-PRIM
1
Cable structure
2
1.LSOH outer jacket
2.Aramid yarns
3.250 µm optical fibers
3
TRUE
COLORS
LSOH
Bendsafe
Datacenter
Easy to terminate
Configuration
DC-PRIM
Applications
No. of fibers
12
24
Outer diameter [mm]
3.0
3.5
350/150
350/150
8
9
45 (depends on fiber type)
50 (depends on fiber type)
Tensile load perm/inst. [N]
Weight [kg/km]
Min. bend radius [mm]
Min. bend radius [mm]
150
ÆÆ
Optical cable with aramid yarns reinforcement
ÆÆ
Customer connection, fully dielectric cable
ÆÆ
MTP/MPO termination cable
ÆÆ
LAN and FTTX networks
ÆÆ
Distribution network
ÆÆ
Inside house OLT connection
ÆÆ
Data Center connections cable
Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
1-12
1
2
3
4
5
6
7
8
9
10
11
12
Features
Fiber
ÆÆ
Aramid strength element
Color
red
green
blue
yellow
white
grey
brown
violet
aqua
black
orange
pink
ÆÆ
250 µm optical fibers (12-24)
13-24
13
14
15
16
17
18
19
20
21
22
23
24
ÆÆ
LSOH outer jacket
Fiber
Operating temperature
blue
*Fiber with black mark to identify fibers 13-24
yellow
white
grey
brown
violet
brown
dark
green
orange
+100
pink
+70°C
+55°C
-5°C
TRANSPORT
green
OPERATION
red
temperature [°C]
Color*
INSTALLATION
Code
-20°C
-40°C
-100
ftth DC-PRIM
| 45
ftth
FTTH EAC-RAs
EAC-Ras
Cable structure
1.LSOH outer jacket
2.Dielectric strength members
3.900 µm semi tight buffer (LSOH)
with colored 250 µm optical fiber
1
2
3
Last mile
connection outdoor
LSOH
FlexibleEasy to
Easy
to terminate
terminate
Bendsafe
FTTH
Configuration
EAC-Ras
Version
Fibers
Nominal
weight
±5%
[kg/km]
Ø
± 5%
[mm]
Buffers
Max.
tensile
load [N]
Applications
Crush
[N/10 cm]
installation
8F
8
8
8.7
68
400
12F
12
12
8.7
72
400
16F
16
16
12.0
98
600
24F
24
24
12.0
106
600
2
3
4
5
6
7
For laying in risers
ÆÆ
FTTH feeder
ÆÆ
Easy access and installation
Features
F-FTTH (according to DIN VDE 0888 & IEC 60304)
1
Distribution cable
ÆÆ
1000
Available colors
1-12
ÆÆ
8
9
10
11
ÆÆ
FRP strength members inside cable jacket
ÆÆ
Optical fibers in bundles
ÆÆ
2-24 elements in cable
ÆÆ
LSOH UV resistant outer jacket (ivory by default,
various colors available)
12
Fiber
Operating temperature
green
yellow
violet
white
orange
grey
brown
black
aqua
pink
Color
red
blue
green
yellow
violet
white
orange
grey
brown
black
aqua
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
600/900 µm
Fiber
Code
Color
red
blue
green
yellow
violet
white
orange
grey
brown
black
aqua
pink
Color*
red
blue
green
yellow
violet
white
orange
grey
brown
dark
green
aqua
pink
250 µm
600/900 µm
*Buffer with black mark to identifiy fibers 13-24
+100
+70°C
+55°C
-5°C
TRANSPORT
blue
OPERATION
red
250 µm
INSTALLATION
Color
temperature [°C]
Buffer
-20°C
-40°C
-100
Fiber extraction up to 25 m
Fiber extraction
46 | ftth EAC-RAs cables
ftth
FTTH EAC-RAm
EAC-RAm
Cable structure
1.LSOH outer jacket
2.Dielectric strength members
3.FlexModules with 250 µm colored fiber
1
2
3
Easy Section
Module
Last mile
connection outdoor
LSOH
Easy to terminate
Flexible
Bendsafe
FTTH
Configuration
Last mile
connection outdoor
Version
EAC-RAm
Fibers
Ø ± 5%
[mm]
FlexModules
Nominal
weight ±10%
[kg/km]
Max. tensile load
[N]
ε=0.6% Δ α≤ 0.1 dB,
reversible
Crush
[N/10 cm]
2F FlexModules
12-18
6-9
8,7
69
400
20-30
10-15
9,5
79
400
32-48
16-24
12,0
106
600
16-36
4-9
8,7
70
400
40-48
10-12
9,5
78
400
52-60
13-15
10,5
85
400
64-96
16-24
12,0
110
600
500
Applications
ÆÆ
Distribution cable
ÆÆ
For laying in risers
ÆÆ
FTTH feeder
ÆÆ
Easy access and installation
4F FlexModules
Features
500
6F FlexModules
70
400
30-72
5-12
78-96
13-16
10,5
90
400
12,0
112
600
102-144
17-24
13,0
130
600
16-32
2-4
8,7
67
400
40-96
5-12
10,5
89
400
24-48
2-4
8,7
70
400
60-120
5-8
10,5
90
400
48
9-12
12,0
115
600
2-24 elements in cable
ÆÆ
LSOH UV resistant outer jacket (ivory by default,
various color available)
500
Operating temperature
+100
8F FlexModules
+70°C
temperature [°C]
500
12F FlexModules
500
+55°C
-5°C
TRANSPORT
8,7
Optical fibers in bundles
ÆÆ
OPERATION
2-4
FRP strength members inside cable jacket
ÆÆ
INSTALLATION
12-24
ÆÆ
-20°C
-40°C
F-FTTH (according to DIN VDE 0888 & IEC 60304)
1-12
1
2
3
4
5
6
7
8
9
10
11
12
Color 250 µm
red
blue
green
yellow
violet
white
orange
grey
brown
black
aqua
pink
1-12
1
2
3
4
5
6
7
8
9
10
11
12
Color
red
blue
green
yellow
violet
white
orange
grey
brown
black
aqua
pink
13-24
13
14
15
16
17
18
19
20
21
22
23
24
red
blue
green
yellow
violet
white
orange
grey
brown
dark
green
aqua
pink
-100
Fiber
Fiber extraction up to 25 m
Module
Fiber extraction
Module
Color*
*Black mark to identify FlexModules 13-24
ftth EAC
| 47
ftth
FTTH DAC-BURRY
DAC-Burry
1
Cable structure
2
1.PP/HDPE outer jacket
2.Aramid yarns
3.Central Loose tube (PBT)
with 250 µm colored fibers in filling gel
4.Dielectric strength members in the jacket
Direct buried
Last mile
connection outdoor
FTTH
Hi-crush
4
3
Compact design
Configuration
DAC-BURRY
Version
Fibers
Fibers
per tube
Ø
± 5%
[mm]
Nominal
weight PE
± 5%
[kg/km]
1T x 2F
2
2
6.2
32
1T x 4F
4
4
6.2
32
1Tx 6F
6
6
6.2
32
1T x 8F
8
8
6.2
32
1T x 12F
12
12
6.2
32
Max. tensile load [N]
installation
operation
650
Applications
Crush
[N/10 cm]
250
3500
ÆÆ
Optical access cable with aramid yarns reinforcement
ÆÆ
Direct buried design
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
ÆÆ
High crush resistance (3,5kN)
ÆÆ
Installation into existing ducts or direct buried
Features
Available colors
T-Telecom (according to IEC 60304) - Fibers in tube
1-12
1
2
3
4
5
6
7
8
9
10
11
12
Code
Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
ÆÆ
Central Loose tube (PBT) with filling compound
ÆÆ
Up to 12 optical fibers (250 µm)
ÆÆ
Aramid yarns as strain relief and water absorbent
ÆÆ
Embedded FRP strength members
ÆÆ
Highly resistant outer jacket made of hard polyolefin material, UV resistant
Operating temperature
+100
-40°C
-100
48 | ftth DAC-BURRY cables
TRANSPORT
OPERATION
-15°C
INSTALLATION
temperature [°C]
+70°C
+55°C
ftth
VC-T60
vc-t60
Cable structure
1.HDPE UV resistant outer jacket
2.Aramid yarns
3.Inner LSOH jacket
4.FRP rods
5.Module with optical fibers
1
3
2
5
4
TRUE
COLORS
LSOH
Bendsafe
Easy-strip
Easy to terminate
Semi-tight
Datacenter
Configuration
VC-t60
1-4
allowed
static
1
5.6
30
1200
400
Applications
Crush
[N/10 cm]
2000
ÆÆ
Drop cable for FTTH networks
ÆÆ
Optical access cable with aramid yarns reinforcement
ÆÆ
Direct buried construction
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
Features
ÆÆ
Aramid yarns as strength and water absorbent
elements
ÆÆ
Easy strip buffer or modules with optical fibers
ÆÆ
Embedded strength members (FRP)
ÆÆ
Highly resistant outer jacket made of HDPE
material
ÆÆ
UV stabilized
Operating temperature
+100
+70°C
span: 100 m
sag: 2.2 m
+55°C
-5°C
TRANSPORT
NESC Light
OPERATION
1-4
Total
elements
Nominal
weight
±5%
[kg/km]
INSTALLATION
1-4F
Fibers
Max. tensile load
[N]
Ø
± 5%
[mm]
temperature [°C]
Version
Fibers
per
module
-20°C
-40°C
NSC Medium
span: 55 m
-100
sag: 1.1 m
NESC Heavy
span: 30 m
sag: 0.6 m
ftth VC-t60
| 49
ftth
FTTH aero-df03
aero-df03
Cable structure
4.Central Loose tube (PBT)
with 250 µm colored
fibers in filling gel
5.FRP strength member
1.PE jacket
2.Ripcord
3.Water blocking yarns
Last mile
connection outdoor
Aerial
4
3
5
Telecom
Hi-crush
FTTH
1
2
Cable variants
Version
AERO-DF03
AERO-DF03
Fiber count
1-12
16-24
Cable dimensions [mm]
8.3 x 4.6 (±3%)
8.7 x 5.0 (-3%)
Cable weight [kg/km]
37
38
Max. installation tension[N]
1300
1300
Applications
Mechanical and enviromental characteristics
ÆÆ
Installation on poles or walls
ÆÆ
Can be installed in pipelines
ÆÆ
Fully dielectric cable
Parameter
Crush performance
5000 N
Bending performance
10 cycles [20 x D]
Water Penetration
3 m sample, 1 m head, 24 h
Features
ÆÆ
Loose tube with filling compound (PBT)
ÆÆ
Up to 24 fibers in a cable
Available colors
ÆÆ
Two FRP strength elements
T-Telecom (according to IEC 60304) - Fibers in tube
ÆÆ
Dry yarns to prevent moisture into cable
ÆÆ
Ripcord yarns For easy jacket removal
ÆÆ
PE UV resistant Jacket
1-12
1
2
3
4
5
6
7
8
9
10
11
12
Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
13-24
13
14
15
16
17
18
19
20
21
22
23
24
Code
Operating temperature
+100
Code
white
violet
orange
grey
yellow
brown
pink
natural
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
NESC Light
aqua
-15°C
span: 120 m
-40°C
sag: 2.4 m
NSC Medium
span: 70 m
sag: 1.4 m
NESC Heavy
span: 40 m
sag: 0.8 m
50 | ftth AERO-DF03
-100
TRANSPORT
blue
OPERATION
green
INSTALLATION
red
temperature [°C]
Color
+70°C
+55°C
Microduct
TRENCH
MICROCABLES
OPTIMAL
DIAMETER
HIGH BLOWING
RANGE
HIGH FIBERS
DENSITY
LOW FRICTION
COEFFICIENT
UNIT DESIGN
microduct
MICRODUCT MK-AX2
MK-AX2
1
Cable structure
1.Polymeric jacket with low coefficient
of friction
2.250 µm colored fibers
Microduct
Generation 1
Last mile
connection outdoor
FTTH
Blowing
installation
Flexible
Compact design
2
Bendsafe
Configuration
MetroJET MK-AX2
Fibers
1T x 2F
2
1.1
1.2
1T x 4F
4
1.1
Max. install.
tension [N]
Crush
[N/10 cm]
ÆÆ
Microduct air-blowing application
ÆÆ
Metro networks
1.4
ÆÆ
Flexible network design
ÆÆ
Distribution network
1.6
1T x 8F
8
1.5
1.8
1T x 10F
10
1.6
2.0
1T x 12F
12
1.6
2.2
15
100
Features
Compatibility table
standard microduct
Version
[mm]
Inner Ø
[mm]
Direct burried ducts
MK-AX2
2-4F
6-12F
Outer
Ø [mm]
Inner
Ø [mm]
7/3.5
7
3.5
Version
2-4F
5/3.5
5
3.5
7/3.8
7
3.8
7/5.5
7
5.5
7/4
7
4
10/8
10
8
10/5.5
10
5.5
12/10
12
10
12/8
12
8
-
12
14/10
14
10
-
Fiber qty
Available colors
2-12
Fiber qty
ÆÆ
250 µm colored fibers
Operating temperature
2.1
14
Central tube without gel
6-12F
3
14/12
Polymeric jacket with low coefficient of friction
ÆÆ
MK-AX2
3/2.1
-
ÆÆ
+100
+70°C
+55°C
2-12
-15°C
OPERATION
1.5
INSTALLATION
6
Outer Ø
Applications
temperature [°C]
1T x 6F
Nominal weight ±10%
[kg/km]
TRANSPORT
Version
Ø
± 5% [mm]
-30°C
-40°C
-100
microduct MK-Ax2 | 53
microduct
MICRODUCT MK-DX2/25
MK-DX2/25
1
Cable structure
2
1.HDPE with low coefficient of friction
2.Aramid yarns
3.Central Loose tube (PBT) with 250 µm
colored fibers in filling gel
Blowing
installation
Flexible
Compact design
Bendsafe
MetroJET MK-DX2/25
Nominal
weight ±10%
[kg/km]
Ø ± 5%
[mm]
Fibers
1T x 2F
2
2.0
3,9
1T x 4F
4
2.0
3.9
1T x 6F
6
2.3
4.4
1T x 8F
8
2.3
4.5
1T x 10F
10
2.3
4.6
1T x 12F
12
2.3
4.6
Applications
Max. installation
tension [N]
Crush [N/10 cm]
300
500
direct burried ducts
Inner
Ø
MK-DX2
MK-DX25
3/2.1
3
2.1
-
-
5/3.5
5
3.5
-
7/5.5
7
5.5
10/8
10
8
12/10
12
10
-
14/12
14
12
[mm]
[mm]
Fiber qty
FTTH & Distribution networks
ÆÆ
Flexible network design
ÆÆ
Last mile connection
ÆÆ
Blowing & pulling installation method
Outer
Ø
Inner
Ø
7/3.5
7
3.5
7/3.8
7
3.8
7/4
7
4
10/5.5
10
5.5
-
12/8
12
8
-
-
14/10
14
10
2-4
4-12
Version
[mm]
[mm]
Fiber qty
MKDX2
MKDX25
-
ÆÆ
HDPE with low coefficient of friction
ÆÆ
Aramid yarns
ÆÆ
Central tube with gel
ÆÆ
250 µm colored fibers
ÆÆ
Microbending resistant fiber G657A1 as standard
Operating temperature
+100
+70°C
+55°C
-
-
2-4
4-12
temperature [°C]
standard microduct
Outer
Ø
Microduct cabling system
ÆÆ
Features
Compatibility table
Version
ÆÆ
INSTALLATION
Version
-15°C
-30°C
Available colors
-40°C
T-Telecom (according to IEC 60304) - Fibers in tube
1-12
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code
Color
54 | Microduct MK-DX2/25
-100
TRANSPORT
Last mile
connection outdoor
FTTH
OPERATION
Microduct
Generation 1
3
microduct
MICRODUCT MK-LX4
MK-LX4
Cable structure (MK-LX4)
5.Water blocking yarns
1.HDPE outer jacket
6.Water blocking yarns
2.Loose tubes (PBT)
on strand element
with colored fibers in
7.Ripcord
filling gel
3.Fillers
4.Central strength
member (FRP)
1
2
3
4
5
6
7
Optimal
Diameter
Low Friction
Blowing
installation
Telecom
Microduct
Generation 1
Configuration
MetroJET MK-LX4
Version
Fibers
per
tube
Fibers
Total
elements
Active
tubes
Fillers
Max. tensile
load [N]
Nominal
weight
±10%
[kg/km]
Ø
± 5%
[mm]
1T x 4F
4
4
6
1
5
4.2
8
2T x 4F
8
4
6
2
4
4.2
8
3T x 4F
12
4
6
3
3
4.2
9
4T x 4F
16
4
6
4
2
4.2
9
5T x 4F
20
4
6
5
1
4.2
10
6T x 4F
24
4
6
6
0
4.2
10
installation
operation
250
150
Applications
Crush
[N/10 cm]
ÆÆ
Microduct cabling air-blowing system
ÆÆ
Metro networks
ÆÆ
Flexible network design
ÆÆ
Distribution network
500
Features
ÆÆ
HDPE, UV stabilized outer jacket with low friction
Other fiber counts available on demand
ÆÆ
Loose tubes (and fillers), SZ stranded around
the CSM
Compatibility table
ÆÆ
PBT tubes containing up to 4 optical fibers
ÆÆ
Smallest outer diameter for blowing into 5.5 mm
(ID) ducts
Direct burried ducts
3
2.1
-
5/3.5
5
3.5
-
7/5.5
7
5.5
10/8
10
8
12/10
12
10
14/12
14
12
MK-LX4
-
Fiber qty
4-24
Outer
Ø [mm]
Inner Ø
7/3.5
7
3.5
-
7/3.8
7
3.8
-
7/4
7
4
-
10/5.5
10
5.5
12/8
12
8
14/10
14
10
Version
MK-LX4
[mm]
Operating temperature
+100
+70°C
+55°C
Fiber qty
4-24
Available colors
-30°C
T-Telecom (according to IEC 60304) - Fibers
1-12
1
2
3
4
Code
Color
-40°C
T-Telecom (according to IEC 60304) - Tubes
Tube
1
2
3
4
5
6
red
green
blue
white
violet
orange
Code
red
-15°C
TRANSPORT
3/2.1
[mm]
OPERATION
Inner Ø
[mm]
INSTALLATION
Outer Ø
Version
temperature [°C]
standard microduct
green
blue
white
Color
-100
*In case of lower fiber count some tubes can be replaced by
fillers.
microduct MK-LX4 | 55
microduct
MICRODUCT MK-LXS6/7/8
MK-LXs6/7/8
Cable structure (MK-LXS6)
1.HDPE outer jacket
2.Loose tubes (PBT) with colored fibers
in filling gel
3.Fillers
4.Central strength member (FRP)
5.Water blocking yarns on FRP
6.Water blocking yarns on strand
element
7.Ripcord
1
2
3
4
5
6
7
Optimal
Diameter
Low Friction
Blowing
installation
Telecom
Microduct
Generation 1
Configuration
MetroJET MK-LXS6
Active
tubes
Fillers
6T x 4F
24
4
6
6
0
5.3
18
6T x 6F
36
6
6
6
0
5.3
18
6T x 8F
48
8
6
6
0
5.3
19
6T x 10F
60
10
6
6
0
5.3
19
4T x 12F
48
10
6
4
2
5.3
20
6T x 12F
72
12
6
6
0
5.3
21
Max. tensile
load [N]
installation
650
operation
200
Applications
Crush
[N/10 cm]
Nominal
weight
±10%
[kg/km]
Fibers
8T x 4F
32
4
8
8
0
6.2
28
8T x 6F
48
6
8
8
0
6.2
28
8T x 8F
64
8
8
8
0
6.2
29
8T x 10F
80
10
8
8
0
6.2
30
8T x 12F
96
12
8
8
0
6.2
31
Active
tubes
Fillers
Ø
± 5%
[mm]
Nominal
weight
±10%
[kg/km]
Version
Fibers
12T x 4F
48
4
12
12
0
7.8
47
12T x 6F
72
6
12
12
0
7.8
48
12T x 8F
96
8
12
12
0
7.8
49
12T x 10F
120
10
12
12
0
7.8
50
12T x 12F
144
12
12
12
0
7.8
52
Total
elements
Active
tubes
Other fiber counts available on demand
56 | Microduct MK-LXs6/7/8
Flexible network design
ÆÆ
Distribution network
Features
Max. tensile
load [N]
installation
operation
Crush
ÆÆ
HDPE, UV stabilized outer jacket with low coefficient of friction
ÆÆ
Loose tubes (and fillers), SZ stranded around
the CSM
ÆÆ
PBT tubes containing up to 12 optical fibers
[N/10 cm]
Operating temperature
1200
350
Max. tensile
load [N]
installation
operation
+100
+100
500
MetroJET MK-LXS8
Fibers
per
tube
Metro networks
ÆÆ
temperature
temperature
[°C][°C]
Fillers
Ø
± 5%
[mm]
Version
Total
elements
Microduct cabling air-blowing system
ÆÆ
500
MetroJET MK-LXS7
Fibers
per
tube
ÆÆ
Crush
[N/10 cm]
+70°C
+70°C
+55°C
+55°C
-15°C
-30°C
-30°C
-40°C
-100
-100
1500
550
500
TRANSPORT
TRANSPORT
Total
elements
Nominal
weight
±10%
[kg/km]
OPERATION
OPERATION
Fibers
Ø
± 5%
[mm]
INSTALLATION
INSTALLATION
Version
Fibers
per
tube
microduct
MICRODUCT MK-LXS9/10
MK-LXs9/10
Cable structure (MK-LX9)
1.HDPE outer jacket
2.Loose tubes (PBT) with colored fibers
in filling gel
3.Fillers
4.Central strength member (FRP)
5.Water blocking yarns on FRP
6.Water blocking tape on strand
element
7.Ripcord
3
1
2
4
5
6
7
Optimal
Diameter
Low Friction
Blowing
installation
Telecom
Microduct
Generation 1
Configuration
MetroJET MK-LXS9
Fillers
14T x
12F
168
12
18
14
4
8.7
53
16T x
12F
192
12
18
16
2
8.7
54
18T x
12F
216
12
18
18
0
8.7
55
installation
650
operation
200
Applications
Crush
[N/10 cm]
24T x
12F
Fibers
288
Fibers
per
tube
Total
elements
12
24
Active
tubes
Other fiber counts available on demand
24
Fillers
0
Microduct cabling air-blowing system
ÆÆ
Metro networks
ÆÆ
Flexible network design
ÆÆ
Distribution network
500
Features
MetroJET MK-LXS10
Version
ÆÆ
Max. tensile
load [N]
Ø
± 5%
[mm]
Nominal
weight
±10%
[kg/km]
installation
operation
[N/10 cm]
9.4
72
1000
250
500
Crush
ÆÆ
HDPE, UV stabilized outer jacket with low coefficient of friction
ÆÆ
Loose tubes (and fillers), SZ stranded around
the CSM
ÆÆ
PBT tubes containing up to 12 optical fibers
Operating temperature
+100
+100
+70°C
+70°C
+55°C
+55°C
-15°C
TRANSPORT
TRANSPORT
Active
tubes
Max. tensile
load [N]
OPERATION
OPERATION
Total
elements
Nominal
weight
±10%
[kg/km]
INSTALLATION
INSTALLATION
Fibers
Ø
± 5%
[mm]
temperature
temperature
[°C][°C]
Version
Fibers
per
tube
-30°C
-30°C
-40°C
-100
-100
microduct MK-LXS9/10 | 57
microduct
MICRODUCT MK-LX6
MK-LX6
Cable structure (MK-LX6)
1.HDPE outer jacket
2.Loose tubes (PBT) with colored fibers
in filling gel
3.Fillers
4.Central strength member (FRP)
5.Water blocking yarns on FRP
6.Water blocking yarns on strand element
7.Ripcord
1
2
3
4
5
6
7
Optimal
Diameter
Low Friction
Blowing
installation
Telecom
Microduct
Generation 1
Configuration
MetroJET MK-LX6
Fibers
Total
elements
Active
tubes
Fillers
Ø
± 5%
[mm]
Nominal
weight
±10%
[kg/km]
1T x 4F
4
4
6
1
5
5.6
28
1T x 6F
6
6
6
1
5
5.6
28
1T x 8F
8
8
6
1
5
5.6
28
2T x 6F
12
6
6
2
4
5.6
29
4T x 6F
24
6
6
4
2
5.6
29
6T x 6F
36
6
6
6
0
5.6
29
1T x 12F
12
12
6
1
5
5.6
30
2T x 12F
24
12
6
2
4
5.6
30
3T x 12F
36
12
6
3
3
5.6
30
4T x 12F
48
12
6
4
2
5.6
31
5T x 12F
60
12
6
5
1
5.6
32
6T x 12F
72
12
6
6
0
5.6
33
Max. tensile
load [N]
installation
operation
Applications
Crush
[N/10 cm]
ÆÆ
Microduct cabling air-blowing system
ÆÆ
Metro networks
ÆÆ
Flexible network design
ÆÆ
Distribution network
Features
750
250
1000
ÆÆ
HDPE, UV stabilized outer jacket with low friction
ÆÆ
Loose tubes (and fillers), SZ stranded around
the CSM
ÆÆ
PBT tubes containing 4-12 optical fibers
ÆÆ
Smallest diameter for blowing into 8 mm (ID)
ducts
Operating temperature
+100
Other fiber counts available on demand
1
2
3
4
5
6
7
8
9
10
11
12
Code
Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
-15°C
-30°C
-40°C
T-Telecom (according to IEC 60304) - Tubes
Tube
1
2
3
4
5
6
red
green
blue
white
violet
orange
Code
Color
*In case of lower fiber count some tubes can be replaced by fillers.
58 | Microduct MK-LX6
-100
TRANSPORT
1-12
OPERATION
T-Telecom (according to IEC 60304) - Fibers
temperature [°C]
+70°C
+55°C
Available colors
INSTALLATION
Version
Fibers
per
tube
microduct
MICRODUCT MK-LX7
MK-LX7
Cable structure (MK-LX7)
1.HDPE outer jacket
2.Loose tubes (PBT) with colored fibers
4
in filling gel
3.Fillers
4.Central strength member (FRP)
5.Water blocking yarns on FRP
6.Water blocking yarns on strand element
7.Ripcord
1
3
2
5
6
7
Optimal
Diameter
Low Friction
Blowing
installation
Telecom
Microduct
Generation 1
Configuration
MetroJET MK-LX7
Version
Fibers
per
tube
Fibers
Total
elements
Active
Fillers
tubes
Ø
± 5%
[mm]
Max. tensile load
[N]
Nominal
weight
±10%
[kg/km]
8T x 4F
32
4
8
8
0
6.7
36
8T x 6F
48
6
8
8
0
6.7
37
8T x 8F
64
8
8
8
0
6.7
38
8T x 12F
96
12
8
8
0
6.7
39
installation
1600
operation
600
Applications
Crush
[N/10 cm]
ÆÆ
Microduct cabling air-blowing system
ÆÆ
Metro networks
ÆÆ
Flexible network design
ÆÆ
Distribution network
1000
Features
Other fiber counts available on demand
Available colors
T-Telecom (according to IEC 60304) - Fibers
1-12
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
7
8
Code
Color
ÆÆ
HDPE, UV stabilized outer jacket with low friction
ÆÆ
Loose tubes (and fillers), SZ stranded around
the CSM
ÆÆ
PBT tubes containing 4-12 optical fibers
ÆÆ
Smallest diameter for blowing into 8* and 10 mm
(ID) ducts
* - blowing range may be lower
T-Telecom (according to IEC 60304) - Tubes
1
2
3
4
5
6
Operating
temperature
+100
green
blue
white
violet
orange
*In case of lower fiber count some tubes can be replaced by fillers.
grey
yellow
-15°C
TRANSPORT
red
temperature [°C]
Color
OPERATION
+70°C
+55°C
Code
INSTALLATION
Tube
-30°C
-40°C
-100
Microduct MK-LX7 | 59
microduct
MICRODUCT MK-LX8
MK-LX8
Cable structure
1.HDPE outer jacket
2.Loose tubes (PBT) with colored fibers
in filling gel
3.Fillers
4.Central strength member (FRP)
5.Water blocking yarns on FRP
6.Water blocking yarns on strand element
7.Ripcord
1
2
3
4
5
6
Optimal
Diameter
Low Friction
Blowing
installation
Telecom
Microduct
Generation 1
7
Configuration
MetroJET MK-LX8
Version
Fibers
per
tube
Fibers
Total
elements
Active
tubes
Fillers
Ø
± 5%
[mm]
Nominal
weight
±10%
[kg/km]
Max. tensile
load [N]
installation
operation
Applications
Crush
[N/10 cm]
ÆÆ
Microduct cabling air-blowing system
ÆÆ
Metro networks
ÆÆ
Flexible network design
ÆÆ
Distribution network
1T x 12F
12
12
12
1
11
8.6
53
2T x 12F
24
12
12
2
10
8.6
54
3T x 12F
36
12
12
3
9
8.6
55
4T x 12F
48
12
12
4
8
8.6
56
5T x 12F
60
12
12
5
7
8.6
57
6T x 12F
72
12
12
6
6
8.6
57
ÆÆ
HDPE, UV stabilized outer jacket with low friction
ÆÆ
Loose tubes (and fillers), SZ stranded around
the CSM
ÆÆ
PBT tubes containing 4-12 optical fibers
ÆÆ
Smallest diameter for blowing into 12 mm (ID)
ducts
8T x 12F
96
12
12
8
4
8.6
59
12T x 12F
144
12
12
12
0
8.6
62
2500
600
1000
Other fiber counts available on demand
Features
Available colors
Operating temperature
T-Telecom (according to IEC 60304) - Fibers
1
2
3
4
5
6
7
8
9
10
11
12
+100
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
7
8
9
10
11
12
T-Telecom (according to IEC 60304) - Tubes
Tube
1
2
3
4
5
6
-30°C
Code
Color
-15°C
-40°C
red
green
blue
white
violet
orange
*In case of lower fiber count some tubes can be replaced by fillers.
60 | Microduct MK-LX8
grey
yellow
brown
pink
black
aqua
-100
TRANSPORT
red
temperature [°C]
Color
OPERATION
+70°C
+55°C
Code
INSTALLATION
1-12
microduct
MICRODUCT MK-LX9
MK-LX9
Cable structure
1.HDPE outer jacket
2.Loose tubes (PBT) with colored fibers
in filling gel
3.Fillers
4.Central strength member (FRP)
5.Water blocking yarns on FRP
6.Water blocking yarns on strand element
7.Ripcord
1
3
2
4
5
6
7
Optimal
Diameter
Low Friction
Blowing
installation
Telecom
Microduct
Generation 1
Configuration
MetroJET MK-LX9
Total
elements
Active
tubes
Fillers
±10%
[kg/km]
14T x 12F
168
12
18
14
4
9.2
62
16T x 12F
192
12
18
16
2
9.2
63
18T x 12F
216
12
18
18
0
9.2
64
Max. tensile
load [N]
installation
750
operation
250
Applications
Crush
[N/10 cm]
1000
ÆÆ
Microduct cabling air-blowing system
ÆÆ
Metro networks
ÆÆ
Flexible network design
ÆÆ
Distribution network
Other fiber counts available on demand
Features
Available colors
T-Telecom (according to IEC 60304) - Fibers
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code
Color
ÆÆ
PBT tubes containing up to 12 optical fibers
ÆÆ
Smallest diameter for blowing into 12 mm (ID)
ducts
Operating temperature
T-Telecom (according to IEC 60304) - Tubes
Tube
Loose tubes (and fillers), SZ stranded around
the CSM
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
+100
+70°C
+55°C
INSTALLATION
Color
HDPE, UV stabilized outer jacket with low friction
ÆÆ
temperature [°C]
1-12
ÆÆ
-15°C
TRANSPORT
Fibers
Nominal
weight
Ø
± 5%
[mm]
OPERATION
Version
Fibers
per
tube
-30°C
-40°C
-100
Microduct MK-LX9 | 61
microduct
MICRODUCT MK-LX11
MK-LX11
Cable structure
1.HDPE outer jacket
2.Fillers
3.Loose tubes (PBT) with colored fibers
in filling gel
4.Central strength member (FRP)
5.Water blocking yarns on FRP
6.Water blocking yarns on strand element
7.Ripcord
1
2
3
4
5
6
7
Optimal
Diameter
Low Friction
Blowing
installation
Telecom
Microduct
Generation 1
Configuration
MetroJET MK-LX11
Version
Fibers
per
tube
Fibers
Total
elements
Active
tubes
Fillers
Nominal
weight
Ø
± 5%
[mm]
±10%
[kg/km]
20T x 12F
240
12
24
20
4
10.8
85
22T x 12F
264
12
24
22
2
10.8
86
24T x 12F
288
12
24
24
0
10.8
87
Max. tensile
load [N]
installation
900
operation
350
Applications
Crush
[N/10 cm]
1000
ÆÆ
Microduct cabling air-blowing system
ÆÆ
Metro networks
ÆÆ
Flexible network design
ÆÆ
Distribution network
Other fiber counts available on demand
Features
Available colors
ÆÆ
HDPE, UV stabilized outer jacket with low friction
T-Telecom (according to IEC 60304) - Fibers
ÆÆ
Loose tubes (and fillers), SZ stranded around
the CSM
ÆÆ
PBT tubes containing up to 12 optical fibers
ÆÆ
Smallest outer diameter for blowing into 12 mm
(ID) ducts
4
5
6
7
8
9
10
11
12
Code
Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Operating temperature
T-Telecom (according to IEC 60304) - Tubes
Tube
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code
Color
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
+100
+70°C
+55°C
-15°C
-30°C
-40°C
-100
62 | Microduct MK-LX11
TRANSPORT
3
OPERATION
2
INSTALLATION
1
temperature [°C]
1-12
temperature [°C]
-5°C
-30°C
-40°C
-100
TRANSPORT
OPERATION
INSTALLATION
Telecom
Duct
+100
+70°C
+55°C
telecom duct
TELECOM DUCT BDC-MSA
bdc-MSA
1
Cable structure
1.HDPE outer jacket
2.Fiberglass yarns
3.PET tape
4.Water blocking yarns on FRP
5.Central strength member (FRP)
6.Loose tubes (PBT) with colored fibers
in filling gel
7.Fillers
8.Ripcord
Basic Rodent
Protection
Telecom
2
3
7
4
5
6
8
Duct
Configuration
telecom duct BDC-msa
Version
Fibers
1T x 12F
12
1-6T x 4F
4-24
1T x 6F
6
2T x 6F
12
2T x 12F
24
Fibers
per
tube
Total
elements
12
Ø
± 5%
[mm]
Active
tubes
Max. tensile load
[N]
Nominal
weight PE
±5%
[kg/km]
8.2
installation
operation
1500
550
50
Applications
Crush
[N/10 cm]
ÆÆ
Installation into existing ducts
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
6
1
4
6
1-6
8.2
50
1550
780
6
6
1
8.2
50
1550
780
6
6
2
8.2
50
1550
780
12
6
2
8.2
51
1500
550
ÆÆ
HDPE outer jacket
Features
4T x 6F
24
6
6
4
8.2
51
1550
780
ÆÆ
Optical fibers
3T x 12F
36
12
6
3
8.2
52
1500
550
ÆÆ
Jelly into the Loose tube
6T x 6F
36
6
6
6
8.2
53
1550
780
ÆÆ
4T x 12F
48
12
6
4
8.2
53
1500
550
Loose tubes (PBT Ø 1.8 mm) with filling
compound
ÆÆ
PET tape to prevent moisture into the cable
5
8.2
54
1500
550
6
8.2
54
1500
550
8T x 4F
48
4
8
8
9.3
70
1650
750
8T x 12F
96
12
8
8
9.3
71
1620
750
11T x 12F
132
12
12
11
11.5
102
1620
850
12T x 12F
144
12
12
12
11.5
104
1620
850
13T x 12F
156
12
14
13
12.6
126
2100
850
14T x 12F
168
12
14
14
12.6
126
2100
850
Operating temperature
+100
+70°C
Other fiber counts available on demand
-40°C
T-Telecom (according to IEC 60304) - Fibers
-100
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code
Color
t-telecom (according to IEC 60304) - Tubes
Tube
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code
Color
-5°C
-20°C
Available colors
1-12
+55°C
*In case of lower fiber count some tubes can be replaced by fillers.
64 | telecom duct BDC-MSA
TRANSPORT
6
6
OPERATION
12
12
INSTALLATION
60
72
temperature [°C]
5T x 12F
6T x 12F
1500
telecom duct
TELECOM BDC-MIB
BDC-MIB
1
Cable structure
Basic Rodent
Protection
Telecom
1.HDPE outer jacket
2.Water blocking fiberglass
yarns
3.Water blocking yarns
4.Water blocking tape
5.Central strength
member (FRP)
Duct
6.Loose tubes (PBT)
with colored fibers
in filling gel
7.Fillers
8.Ripcord
2
5
3
4
7
6
8
Configuration
telecom duct BDC-MIB
Version
Fibers
Fibers
per
tube
Total
elements
Ø
± 5%
[mm]
Active
tubes
Nominal
weight
±10%
[kg/km]
Max. tensile
load [N]
installation
operation
Applications
Crush
[N/10 cm]
ÆÆ
For installation into existing duct or directly buried
ÆÆ
Fully dielectric cable
ÆÆ
Basic rodent protection
1-6T x 6F
6-36
6
6
1-6
8.8
63
2800
1500
1-6T x 12F
12-72
12
6
1-6
8.8
66
2800
1000
8T x 6F
48
6
8
8
10.0
77
2800
1500
8T x 12F
96
12
8
8
10.0
82
2800
1000
12T x 12F
144
12
12
12
12.2
117
2800
1000
ÆÆ
FRP strength and anti-buckling rod
16-18T x 12F
192-216
12
18
16-18
12.6
122
2800
1000
ÆÆ
Dry yarns to prevent moisture into the cable
20-24T x 12F
240-288
12
24
20-24
14.2
156
2800
1000
ÆÆ
Loose tubes (PBT Ø 1,8mm) with filling compound
ÆÆ
Optical fibers
ÆÆ
Fibreglass yarns as tensile elements
ÆÆ
UV stabilized HDPE jacket
Features
1500
Other fiber counts available on demand
Available colors
T-Telecom (according to IEC 60304) - Fibers
1
2
3
4
5
6
7
8
9
10
11
12
Operating temperature
Code
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
7
8
9
10
11
12
t-telecom (according to IEC 60304) - Tubes
Tube
1
2
3
4
5
6
Code
Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
PE Black RAL 9005
aqua
+70°C
+55°C
-15°C
TRANSPORT
green
OPERATION
red
temperature [°C]
Color
+100
INSTALLATION
1-12
-40°C
-100
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
telecom duct BDC-MIB | 65
telecom duct
TELECOM DUCT BDC-C0
BDC-c0
1
Cable structure
Basic Rodent
Protection
Telecom
6.Loose tubes (PBT)
with colored fibers
in filling gel
7.Fillers
8.Ripcord
1.HDPE outer jacket
2.Water blocking fiberglass
yarns
3.Water blocking yarns
4.Water blocking tape
5.Central strength
member (FRP)
Duct
2
5
3
4
7
6
8
Configuration
telecom duct bdc-c0
Version
Fibers
per
tube
Fibers
Total
elements
Ø
± 5%
[mm]
Active
tubes
Nominal
weight
±10%
[kg/km]
Max. tensile load
[N]
installation
operation
Applications
Crush
[N/10 cm]
ÆÆ
Installation into existing ducts
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Basic rodent protection
1T x 4F
4
4
6
1
1T x 6F
6
6
6
2
2T x 6F
12
6
6
2
4T x 6F
24
6
6
4
1T x 12F
12
12
6
1
2T x 12F
24
12
6
2
ÆÆ
FRP strength and anti-buckling element
3T x 12F
36
12
6
3
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound (PBT Ø 2.0 mm)
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Fiberglass yarns as tensile elements
ÆÆ
UV stabilized HDPE jacket
10.0
71
2100
1300
10.0
71
2100
1300
Features
1000
4T x 12F
48
12
6
4
5T x 12F
60
12
6
5
6T x 12F
72
12
6
6
8T x 12F
96
12
8
8
11.3
97
2100
1000
12T x 12F
144
12
12
12
13.8
144
2200
1100
16T x 12F
192
12
18
16
14.2
148
2200
1100
18T x 12F
216
12
18
18
14.2
150
2200
1100
24T x 12F
288
12
24
24
16.2
190
2500
1200
2000
Operating temperature
+100
+70°C
+55°C
temperature [°C]
Other fiber counts available on demand
Available colors
T-Telecom (according to IEC 60304) - Fibers
1-12
1
2
3
4
5
6
7
8
9
10
11
12
-40°C
Code
Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
t-telecom (according to IEC 60304) - Tubes
Tube
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code
Color
-15°C
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
66 | telecom duct BDC-C0
-100
TRANSPORT
2000
OPERATION
74
INSTALLATION
10.0
telecom duct
TELECOM BDC-CI
BDC-CI
1
Cable structure
Basic Rodent
Protection
Telecom
1.HDPE outer jacket
2.Water blocking fiberglass
yarns
3.Water blocking yarns
4.Water blocking tape
5.Central strength
member (FRP)
Duct
6.Loose tubes (PBT)
with colored fibers
in filling gel
7.Fillers
8.Ripcord
2
5
3
4
7
6
Configuration
8
telecom duct bdc-cI
Max. tensile
load [N]
Total
elements
Active
tubes
Ø
± 5%
[mm]
Nominal
weight
±10%
[kg/km]
installation
operation
10.0
74
2800
1700
10.0
74
2800
1700
4
4
6
1
1T x 6F
6
6
6
1
2T x 6F
12
6
6
2
1T x 12F
12
12
6
1
10.0
73
2700
1200
4Tx 6F
24
6
6
4
10.0
74
2800
1600
2T x 12F
24
12
6
2
10.0
75
2700
1200
3Tx 12F
36
12
6
3
4T x 12F
48
12
6
4
10.0
82
2700
1200
6T x 12F
72
12
6
6
8T x 12F
96
12
8
8
11.4
101
2700
1200
12T x 12F
144
12
12
12
13.8
146
13T x 12F
156
12
18
13
14.2
149
14T x 12F
168
12
18
14
14.2
150
15T x 12F
180
12
18
15
14.2
151
16T x 12F
192
12
18
16
14.2
152
17T x 12F
204
12
18
17
14.2
153
18T x 12F
216
12
18
18
14.2
154
24T x 12F
288
12
24
24
16.3
191
2700
2900
Applications
2000
1200
3
4
5
Fully dielectric cable
ÆÆ
Basic rodent protection
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound (PBT Ø 2.0 mm)
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Fiberglass yarns as tensile elements
ÆÆ
UV stabilized HDPE jacket
+100
2900
+70°C
+55°C
1400
temperature [°C]
6
7
8
9
10
11
-15°C
12
-40°C
Code
Color
ÆÆ
Operating temperature
T-Telecom (according to IEC 60304) - Fibers
2
High tensile and crush performance
1400
Available colors
1
Installation into existing ducts
ÆÆ
Features
Other fiber counts available on demand
1-12
ÆÆ
TRANSPORT
1T x 4F
Crush
[N/10 cm]
OPERATION
Fibers
INSTALLATION
Version
Fibers
per
tube
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
7
8
9
10
11
12
-100
t-telecom (according to IEC 60304) - Tubes
Tube
1
Code
PE Black
Color
red
2
3
RAL 9005
green
4
5
6
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
telecom duct BDC-CI | 67
telecom duct
TELECOM DUCT BDC-CK
BDC-ck
1
Cable structure
Basic Rodent
Protection
Telecom
6.Loose tubes (PBT)
with colored fibers
3
in filling gel
7.Fillers
7
8.Ripcord
1.HDPE outer jacket
2.Water blocking fiberglass
yarns
3.Water blocking yarns
4.Water blocking tape
5.Central strength
member (FRP)
Duct
2
5
4
6
Configuration
8
telecom duct bdc-ck
Total
elements
Active
tubes
Ø
± 5%
[mm]
Nominal
weight
Max. tensile load
[N]
Version
Fibers
Fibers
per
tube
1T x 4F
4
4
6
1
10.1
77
1T x 6F
6
6
6
1
10.1
78
1T x 8F
8
8
6
1
10.1
79
1T x 10F
10
10
6
1
10.1
80
1T x 12F
12
12
6
1
10.2
81
4100
2000
2T x 6F
12
6
6
2
10.1
78
4000
2400
2T x 12F
24
12
6
2
10.2
81
4100
2000
4T x 6F
24
6
6
4
10.1
79
4000
2400
3T x 12F
36
12
6
3
10.2
82
4100
2000
6T x 6F
36
6
6
6
10.1
82
4000
2400
±10%
[kg/km]
installation
operation
Crush
[N/10 cm]
Applications
2400
12
6
4
10.2
83
4100
2000
8T x 6F
48
6
8
8
11.4
98
4100
2700
5T x 12F
60
12
6
5
10.2
84
6T x 12F
72
12
6
6
10.2
85
4100
2000
96
12
8
8
11.4
104
4200
2300
144
12
12
12
13.9
151
4200
2000
16T x 12F
192
12
18
16
14.1
191
18T x 12F
216
12
18
18
14.1
191
4100
1800
24T x 12F
288
12
24
24
15.9
240
4000
1900
2000
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
t-telecom (according to IEC 60304) - Tubes
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
68 | telecom duct BDC-Ck
Optical fibers
ÆÆ
Loose tube with filling compound (PBT Ø 2.0 mm)
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Fiberglass yarns as tensile elements
ÆÆ
UV stabilized HDPE jacket
+70°C
+55°C
Code
Color
FRP strength and anti-buckling element
ÆÆ
+100
T-Telecom (according to IEC 60304) - Fibers
Tube
ÆÆ
Operating temperature
Available colors
Color
Basic rodent protection
Features
Other fiber counts available on demand
1-12
Fully dielectric cable
ÆÆ
temperature [°C]
8T x 12F
12T x 12F
High tensile and crush performance
ÆÆ
-15°C
-40°C
-100
TRANSPORT
48
Installation into existing ducts
ÆÆ
OPERATION
4T x 12F
ÆÆ
INSTALLATION
4000
telecom duct
TELECOM DUCT DDC-SI
ddc-SI
1
Cable structure
1.HDPE outer jacket
2.Fiberglass yarns
3.HDPE inner jacket
4.Water blocking yarns
5.Central strength member (FRP)
6.Loose tubes (PBT)
with colored fibers in filling gel
7.Fillers
8.Ripcords
High Rodent
Protection
Telecom
Duct
2
3
7
4
5
6
Direct buried
8
Configuration
telecom duct DDC-SI
Version
Fibers
per
tube
Fibers
Total
elements
Ø
± 5%
[mm]
Active
tubes
Nominal
weight
±10%
[kg/km]
Max. tensile
load [N]
allowed
static
1-6T x 4F
4 - 24
4
6
1-6
9.3
67
2800
800
8T x 4F
32
4
8
8
10.3
83
2700
650
1-6T x 6F
6 - 36
6
6
1-6
9.4
68
2800
800
Applications
Crush
[N/10 cm]
ÆÆ
Installation into existing ducts
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
High rodent protection
8T x 6F
48
6
8
8
10.4
85
2800
800
1-6T x 12F
12 - 72
12
6
1-6
9.4
73
2700
650
8T x 12F
96
12
8
8
10.4
88
2700
670
ÆÆ
FRP strength and anti-buckling element
670
ÆÆ
Optical fibers
ÆÆ
Loose tube (PBT Ø 1.6mm) with filling compound
ÆÆ
Dry yarns to prevent moisture into the cable
Available colors
ÆÆ
T-Telecom (according to IEC 60304) - Fibers
Fiberglass yarns as tensile and water absorbent
elements
ÆÆ
Double HDPE jacket
ÆÆ
LSOH, PA etc. outer jacket option
12T x 12F
144
12
12
12
12.3
122
2800
2000
Features
Other fiber counts available on demand
1-12
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code
Operating temperature
+100
t-telecom (according to IEC 60304) - Tubes
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code
Color
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
+70°C
+55°C
-15°C
TRANSPORT
2
OPERATION
1
temperature [°C]
Tube
INSTALLATION
Color
-40°C
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
-100
telecom duct DDC-SI | 69
telecom duct
TELECOM DUCT DDC-CI
ddc-ci
1
Cable structure
1.HDPE outer jacket
2.Fiberglass yarns
3.HDPE inner jacket
4.Water blocking
yarns
5.Central strength
member (FRP)
6.Loose tubes (PBT)
with colored fibers
in filling gel
7.Fillers
8.Ripcords
2
3
7
4
5
6
High Rodent
Protection
Telecom
Hi-crush
Direct buried
Duct
8
Configuration
telecom duct DDC-ci
Version
Fibers
per
tube
Fibers
Total
elements
Ø
± 5%
[mm]
Active
tubes
Nominal
weight
±10%
[kg/km]
Max. tensile
load [N]
allowed
static
1-6T x 4F
4 - 24
4
6
1-6
11.7
73
4400
2600
1-6T x 6F
6 - 36
6
6
1-6
11.7
73
4400
2600
1-6T x 12F
12 - 72
12
6
1-6
11.8
105
4100
2000
Applications
Crush
[N/10 cm]
ÆÆ
Installation into existing ducts
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
High rodent protection
8T x 6F
48
6
8
8
13.0
124
4100
2300
8T x 12F
96
12
8
8
13.0
128
4100
2000
12T x 12F
144
12
12
12
15.5
180
4600
2200
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound (PBT Ø 2.0 mm)
ÆÆ
Dry yarns and tape to prevent moisture into the
cable
ÆÆ
Glass yarns as tensile elements
ÆÆ
Double HDPE jacket
ÆÆ
LSOH, PA etc. outer jacket option
16T x 12F
192
12
16
16
15.9
185
4600
2200
18T x 12F
216
12
18
18
15.9
187
4600
2200
24T x 12F
288
12
24
24
17.9
193
5000
2600
Features
3500
Other fiber counts available on demand
Available colors
Operating temperature
T-Telecom (according to IEC 60304) - Fibers
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code
Color
t-telecom (according to IEC 60304) - Tubes
Tube
1
2
3
4
5
6
7
8
9
10
11
12
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
Code
Color
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
70 | telecom duct DDC-ci
+100
+70°C
+55°C
-15°C
-40°C
-100
TRANSPORT
3
OPERATION
2
INSTALLATION
1
temperature [°C]
1-12
Telecom
Aerial
telecom aerialAero-DF03
Cable structure
1.PE jacket
2.Ripcord
3.Water blocking yarns
Last mile
connection outdoor
Aerial
1
4.Central Loose tube (PBT)
with 250 µm colored
fibers in filling gel
5.FRP strength member
2
4
3
5
Telecom
Hi-crush
FTTH
TELECOM AERIAL Aero-DF03
Cable variants
Version
AERO-DF03
AERO-DF03
Fiber count
1-12
16-24
Cable dimensions [mm]
8.3 x 4.6 (±3%)
8.7 x 5.0 (-3%)
Cable weight [kg/km]
37
38
Max. installation tension[N]
1300
1300
Applications
Mechanical and enviromental characteristics
ÆÆ
Installation on poles or walls
ÆÆ
Can be installed in pipelines
ÆÆ
Fully dielectric cable
Parameter
Crush performance
5000 N
Bending performance
10 cycles [20 x D]
Water Penetration
3 m sample, 1 m head, 24 h
Features
ÆÆ
Loose tube with filling compound (PBT)
ÆÆ
Up to 24 fibers in a cable
Available colors
ÆÆ
Two FRP strength elements
T-Telecom (according to IEC 60304) - Fibers in tube
ÆÆ
Dry yarns to prevent moisture into cable
ÆÆ
Ripcord yarns For easy jacket removal
ÆÆ
PE UV resistant Jacket
1-12
1
2
3
4
5
6
7
8
9
10
11
12
Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
13-24
13
14
15
16
17
18
19
20
21
22
23
24
Code
Operating temperature
+100
Code
white
violet
orange
grey
yellow
brown
pink
natural
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
NESC Light
aqua
-15°C
TRANSPORT
blue
OPERATION
green
INSTALLATION
red
temperature [°C]
Color
+70°C
+55°C
span: 120 m
-40°C
sag: 2.4 m
-100
NSC Medium
span: 70 m
sag: 1.4 m
NESC Heavy
span: 40 m
sag: 0.8 m
72 | telecom AERIAL Aero-DF03
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
telecom aerialAero-AS02 2.0 mm
TELECOM AERIAL Aero-AS02 2.0 mm
1
Cable structure
Aerial
Telecom
6.Fillers
7.Water blocking tape
8.Ripcord
1.HDPE outer jacket
2.Aramid yarns
3.Central strength
member (FRP)
4.Loose tubes (PBT)
with colored fibers in
filling gel
5.Water blocking yarns
FTTH
6
2
3
4
7
5
8
Configuration
AERO-AS02 PBT TUBES 2.0 mm
Version
1-6T x 6F
Fibers
Fibers
per
tube
Total
elements
Active
tubes
Ø
± 5%
[mm]
Nominal
weight
±10%
[kg/km]
Tensile load [N]
allowed
static
6 – 36
6
6
1–6
10.0
73
2200
1200
1-6T x 12F 12 – 72
12
6
1–6
10.0
75
2100
1000
8T x 12F
96
12
8
8
11.3
98
2200
1100
12T x 12F
144
12
12
12
13.8
143
2100
1000
Applications
Crush
[N/10 cm]
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
2000
Other fiber counts available on demand
Features
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Loose tube (PBT Ø 2.0 mm) with filing compound
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Optical fibers
ÆÆ
Fillers (if applicable)
ÆÆ
Water-swellable tape
ÆÆ
Aramid yarns as strain relief and water absorbent
ÆÆ
UV stabilized HDPE jacket
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
NESC Light
span: 130 m
sag: 2.6 m
NSC Medium
span: 85 m
PE Black RAL 9005
sag: 1.7Grey
m
LSOH
RAL 7022 LSOH Light Grey RAL 7037
NESC Heavy
span: 45 m
sag: 0.9 m
telecom AERIAL AERO-AS02 2.0 mm | 73
telecom aerialAero-AS03 2.0 mm
TELECOM AERIAL Aero-AS03 2.0 mm
1
Cable structure
Aerial
Telecom
6.Fillers
7.Water blocking tape
8.Ripcord
1.HDPE outer jacket
2.Aramid yarns
3.Central strength
member (FRP)
4.Loose tubes (PBT)
with colored fibers in
filling gel
5.Water blocking yarns
FTTH
2
6
3
4
7
5
8
Configuration
AERO-AS02 PBT TUBES 2.0 mm
Version
Fibers
Fibers
per
tube
Total
elements
Active
tubes
Ø
± 5%
[mm]
Nominal
weight
±10%
[kg/km]
1-6T x 6F
6-36
6
6
1-6
10.0
1-6T x 12F
12-72
12
6
1-6
8T x 12F
96
12
8
12T x 12F
144
12
12
Tensile load [N]
allowed
static
75
3200
1800
10.1
77
3100
1500
8
11.3
100
3100
1500
12
13.8
146
3100
1500
Crush
[N/10 cm]
2000
Applications
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
Other fiber counts available on demand
Available colors
Features
T-Telecom (according to IEC 60304) - Fibers
3
4
5
6
7
8
9
10
11
12
Code
Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
t-telecom (according to IEC 60304) - Tubes
Tube
1
2
3
4
5
6
7
8
9
10
11
12
Code
Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
*In case of lower fiber count some tubes can be replaced by fillers.
black
aqua
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Loose tube (PBT Ø 2.0 mm) with filing compound
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Optical fibers
ÆÆ
Fillers (if applicable)
ÆÆ
Water-swellable tape
ÆÆ
Aramid yarns as strain relief and water absorbent
ÆÆ
UV stabilized HDPE jacket
Operating temperature
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
+100
NESC Light
+70°C
temperature [°C]
span: 190 m
sag: 3.8 m
NSC Medium
span: 130 m
sag: 2.6 m
NESC Heavy
span: 75 m
sag: 1.5 m
74 | telecom AERIAL AERO-AS03 2.0 mm
+55°C
TRANSPORT
2
OPERATION
1
INSTALLATION
1-12
-15°C
-40°C
PE Black RAL 9005
-100
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
telecom aerialAero-AS03 2.5 mm
TELECOM AERIAL Aero-AS03 2.5 mm
1
Cable structure
Aerial
Telecom
6.Fillers
7.Water blocking tape
8.Ripcord
1.HDPE outer jacket
2.Aramid yarns
3.Central strength
member (FRP)
4.Loose tubes (PBT)
with colored fibers in
filling gel
5.Water blocking yarns
FTTH
2
6
3
4
7
5
8
Configuration
AERO-AS03 PBT TUBES 2.5 mm
Version
Fibers
Fibers
per
tube
Total
elements
Active
tubes
Ø
± 5%
[mm]
Nominal
weight
±10%
[kg/km]
Max. tensile load
[N]
installation
operation
1-6T x 6F
6-36
6
6
1-6
11.4
97
3300
2200
1-6T x 12F
12-72
12
6
1-6
11.4
98
3200
2100
8T x 12F
96
12
8
8
13.0
127
3200
2100
12T x 12F
144
12
12
12
16.1
193
3300
2200
Applications
Crush
[N/10 cm]
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
3000
Other fiber counts available on demand
Features
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Loose tube (PBT Ø 2.0 mm) with filing compound
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Optical fibers
ÆÆ
Fillers (if applicable)
ÆÆ
Water-swellable tape
ÆÆ
Aramid yarns as strain relief and water absorbent
ÆÆ
UV stabilized HDPE jacket
Operating temperature
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
+100
NESC Light
+70°C
NSC Medium
span: 140 m
PE Black RAL 9005
sag: 2.8
m
LSOH
Grey
RAL 7022 LSOH Light Grey RAL 7037
TRANSPORT
OPERATION
+55°C
INSTALLATION
sag: 3.8 m
temperature [°C]
span: 190 m
-15°C
-40°C
-100
NESC Heavy
span: 80 m
sag: 1.6 m
telecom AERIAL AERO-AS03 2.5 mm | 75
telecom aerialAero-AS04 2.0 mm
TELECOM AERIAL Aero-AS04 2.0 mm
1
Cable structure
Aerial
Telecom
6.Fillers
7.Water blocking tape
8.Ripcord
1.HDPE outer jacket
2.Aramid yarns
3.Central strength
member (FRP)
4.Loose tubes (PBT)
with colored fibers in
filling gel
5.Water blocking yarns
FTTH
2
6
3
4
7
5
8
Configuration
AERO-AS04 PBT TUBES 2.0 mm
Version
Fibers
Fibers
per
tube
Total
elements
Active
tubes
Ø
± 5%
[mm]
Nominal
weight
±10%
[kg/km]
Max. tensile load
[N]
installation
operation
1T x 12F
12
12
6
1
10,1
75
4000
2000
2T x 6F
12
6
6
2
10,1
75
4100
2400
2T x 12F
24
12
6
2
10,1
76
4000
2000
4T x 6F
24
6
6
4
10,1
76
4100
2400
3T x 12F
36
12
6
3
10,1
80
4000
2000
6T x 6F
36
6
6
6
10,1
76
4100
2400
4T x 12F
48
12
6
4
10,1
80
4000
2000
8T x 6F
48
6
8
8
11.3
97
4200
2500
6T x 12F
72
12
6
6
10,1
82
4000
2000
8T x 12F
96
12
8
8
11,4
103
4200
12T x 12F
144
12
12
12
13,9
149
4100
Other fiber counts available on demand
Applications
Crush
[N/10 cm]
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
Features
2000
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Loose tube (PBT Ø 2.0 mm) with filing compound
ÆÆ
6-12 elements SZ stranded cable core
2100
ÆÆ
Optical fibers
2000
ÆÆ
Fillers (if applicable)
ÆÆ
Water-swellable tape
ÆÆ
Aramid yarns as strain relief and water absorbent
ÆÆ
UV stabilized HDPE jacket
Operating temperature
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
+100
NSC Light
+70°C
NSC Medium
span: 170 m
PE Black RAL 9005
TRANSPORT
OPERATION
+55°C
INSTALLATION
sag: 5.0 m
temperature [°C]
span: 250 m
-15°C
-40°C
-100
LSOH
RAL 7022PELSOH
BlackLight
RAL 9005
Grey RAL 7037
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
sag: 3.4Grey
m
NSC Heavy
span: 95 m
sag: 1.9 m
76 | telecom AERIAL AERO-AS04 2.0 mm
telecom aerialAero-AS04 2.5 mm
TELECOM AERIAL Aero-AS04 2.5 mm
1
Cable structure
Aerial
Telecom
6.Fillers
7.Water blocking tape
8.Ripcord
1.HDPE outer jacket
2.Aramid yarns
3.Central strength
member (FRP)
4.Loose tubes (PBT)
with colored fibers in
filling gel
5.Water blocking yarns
FTTH
2
6
3
4
7
5
8
Configuration
AERO-AS04 PBT TUBES 2.5 mm
Version
Fibers
Fibers
per
tube
Total
elements
Active
tubes
Ø
± 5%
[mm]
Nominal
weight
±10%
[kg/km]
Max. tensile load
[N]
installation
operation
1-6T x 6F
6-36
6
6
1-6
11.4
98
4200
2900
1-6T x 12F
12-72
12
6
1-6
11.4
99
4100
2600
8T x 12F
96
12
8
8
13.1
128
4200
2800
12T x 12F
144
12
12
12
16.2
194
4100
2700
Applications
Crush
[N/10 cm]
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
3000
Other fiber counts available on demand
Features
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Loose tube (PBT Ø 2.0 mm) with filing compound
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Optical fibers
ÆÆ
Fillers (if applicable)
ÆÆ
Water-swellable tape
ÆÆ
Aramid yarns as strain relief and water absorbent
ÆÆ
UV stabilized HDPE jacket
Operating temperature
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
+100
NESC Light
+70°C
NSC Medium
span: 190 m
PE Black RAL 9005
LSOH
Grey
RAL 7022 LSOH Light Grey RAL 7037
sag: 3.8
m
TRANSPORT
OPERATION
+55°C
INSTALLATION
sag: 5.2 m
temperature [°C]
span: 260 m
-15°C
-40°C
-100
NESC Heavy
span: 110 m
sag: 2.2 m
telecom AERIAL AERO-AS04 2.5 mm | 77
telecom aerialAero-AS06 2.0 mm
TELECOM AERIAL Aero-AS06 2.0 mm
1
Cable structure
Aerial
Telecom
1.HDPE outer jacket
2.Aramid yarns
3.Central strength
member (FRP)
4.Loose tubes (PBT)
with colored fibers in
filling gel
5.Water blocking yarns
FTTH
6.Fillers
7.Water blocking tape
8.Ripcord
2
6
3
4
7
5
8
Configuration
AERO-AS06 PBT TUBES 2.0 mm
Qnt
Version
Fibers
Fibers
per
tube
Total
elements
Active
tubes
Ø
± 5%
[mm]
Nominal
weight
±10%
[kg/km]
Max. tensile load
[N]
installation
operation
1-6T x 6F
6-36
6
6
1-6
10.2
82
6100
3600
1-6T x 12F
12
12
6
1-6
10.3
88
6200
3000
8T x 12F
96
12
8
8
11.5
110
6200
2800
12T x 12F
144
12
12
12
13.9
154
6100
3000
Applications
Crush
[N/10 cm]
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
2000
Features
Other fiber counts available on demand
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Loose tube (PBT Ø 2.0 mm) with filing compound
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Optical fibers
ÆÆ
Fillers (if applicable)
ÆÆ
Water-swellable tape
ÆÆ
Aramid yarns as strain relief and water absorbent
ÆÆ
UV stabilized HDPE jacket
Operating temperature
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
+100
NESC Light
+70°C
NSC Medium
NESC Heavy
span: 140 m
sag: 2.8 m
78 | telecom AERIAL Aero-AS06 2.0 mm
TRANSPORT
-15°C
-40°C
span: 250 m
sag: 5.0 m
OPERATION
sag: 7.2 m
+55°C
INSTALLATION
temperature [°C]
span: 360 m
PE Black RAL 9005
-100
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
telecom aerialAero-AS06 2.5 mm
TELECOM AERIAL Aero-AS06 2.5 mm
1
Cable structure
Aerial
Telecom
6.Fillers
7.Water blocking tape
8.Ripcord
1.HDPE outer jacket
2.Aramid yarns
3.Central strength
member (FRP)
4.Loose tubes (PBT)
with colored fibers in
filling gel
5.Water blocking yarns
FTTH
2
6
3
4
7
5
8
Configuration
AERO-AS06 PBT TUBES 2.5 mm
Version
Fibers
Fibers
per
tube
Total
elements
Active
tubes
Ø
± 5%
[mm]
Nominal
weight
±10%
[kg/km]
Max. tensile load
[N]
installation
operation
1-6T x 6F
6-36
6
6
1-6
11.6
101
6100
4200
1-6T x 12F
12-72
12
6
1-6
11.6
104
6300
4100
8T x 12F
96
12
8
8
13.2
132
6100
4000
12T x 12F
144
12
12
12
16.2
198
6100
4000
Applications
Crush
[N/10 cm]
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
3000
Other fiber counts available on demand
Features
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
Loose tube (PBT Ø 2.5 mm) with filing compound
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Optical fibers
ÆÆ
Fillers (if applicable)
ÆÆ
Water-swellable tape
ÆÆ
Aramid yarns as strain relief and water absorbent
ÆÆ
UV stabilized HDPE jacket
Operating temperature
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
+100
NESC Light
+70°C
NSC Medium
span: 270 m
PE Black RAL 9005
LSOH
Grey
RAL 7022 LSOH Light Grey RAL 7037
sag: 5.4
m
TRANSPORT
OPERATION
+55°C
INSTALLATION
sag: 7.4 m
temperature [°C]
span: 370 m
-15°C
-40°C
-100
NESC Heavy
span: 150 m
sag: 3.0 m
telecom AERIAL Aero-AS06 2.5 mm | 79
telecom aerialAero-AS09 2.5 mm
TELECOM AERIAL Aero-AS09 2.5 mm
1
Cable structure
Aerial
Telecom
1.HDPE outer jacket
2.Aramid yarns
3.Central strength
member (FRP)
4.Loose tubes (PBT)
with colored fibers in
filling gel
5.Water blocking yarns
FTTH
6.Fillers
7.Water blocking tape
8.Ripcord
2
6
3
4
7
5
8
Configuration
AERO-AS09 PBT TUBES 2.5 mm
Qnt
Version
Fibers
Fibers
per
tube
Total
elements
Active
tubes
Ø
± 5%
[mm]
Nominal
weight
±10%
[kg/km]
Max. tensile load
[N]
installation
operation
1-6T x 6F
6-36
6
6
1-6
11.6
101
9300
6600
1-6T x 12F
12-72
12
6
1-6
11.7
104
9200
6000
8T x 12F
96
12
8
8
13.2
138
9200
6100
12T x 12F
144
12
12
12
16.2
203
9200
6100
Applications
Crush
[N/10 cm]
3000
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
ÆÆ
UV resistant
Other fiber counts available on demand
Features
ÆÆ
FRP strength and anti-buckling element Ø 2.5 mm
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound (PBT Ø 2.5 mm)
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Dry yarns to prevent moisture into cable
ÆÆ
Aramid yarns as tensile elements
Operating temperature
+100
+70°C
sag: 10.6 m
TRANSPORT
span: 530 m
+55°C
OPERATION
temperature [°C]
NESC Light
INSTALLATION
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
-15°C
-40°C
NSC Medium
span: 400 m
-100
sag: 8.0 m
NESC Heavy
span: 230 m
sag: 4.6 m
80 | telecom AERIAL Aero-AS09 2.5 mm
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
telecom aerialAero-AS12 2.5 mm
TELECOM AERIAL Aero-AS12 2.5 mm
1
Cable structure
Aerial
Telecom
6.Fillers
7.Water blocking tape
8.Ripcord
1.HDPE outer jacket
2.Aramid yarns
3.Central strength
member (FRP)
4.Loose tubes (PBT)
with colored fibers in
filling gel
5.Water blocking yarns
FTTH
2
6
3
4
7
5
8
Configuration
AERO-AS12 PBT TUBES 2.5 mm
Version
Fibers
Fibers
per
tube
Total
elements
Active
tubes
Ø
± 5%
[mm]
Nominal
weight
±10%
[kg/km]
Max. tensile load
[N]
installation
operation
1-6T x 6F
6-36
6
6
1-6
11.7
106
12700
9000
1-6T x 12F
12-72
12
6
1-6
11.8
110
12500
8000
8T x 12F
96
12
8
8
13.3
143
12200
7800
12T x 12F
144
12
12
12
16.3
208
12100
8000
Applications
Crush
[N/10 cm]
3000
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
ÆÆ
UV resistant
Other fiber counts available on demand
Features
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound (PBT Ø 2.5 mm)
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Dry yarns to prevent moisture into cable
ÆÆ
Aramid yarns as tensile elements
Operating temperature
+100
+70°C
sag: 14 m
TRANSPORT
OPERATION
span: 700 m
+55°C
INSTALLATION
NESC Light
temperature [°C]
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
-15°C
-40°C
NSC Medium
span: 530 m
-100
PE Black RAL 9005
sag: 10.6
m
LSOH
Grey
RAL 7022 LSOH Light Grey RAL 7037
NESC Heavy
span: 310 m
sag: 6.2 m
telecom AERIAL Aero-AS12 2.5 mm | 81
telecom aerialAero-AS14 2.5 mm
TELECOM AERIAL Aero-AS14 2.5 mm
1
Cable structure
Aerial
Telecom
1.HDPE outer jacket
2.Aramid yarns
3.Central strength
member (FRP)
4.Loose tubes (PBT)
with colored fibers in
filling gel
5.Water blocking yarns
FTTH
6.Fillers
7.Water blocking tape
8.Ripcord
2
6
3
4
7
5
8
Configuration
AERO-AS14 PBT TUBES 2.5 mm
Qnt
Version
Fibers
Fibers
per
tube
Total
elements
Active
tubes
Ø
± 5%
[mm]
Nominal
weight
±10%
[kg/km]
Max. tensile load
[N]
installation
operation
1-6T x 6F
6-36
6
6
1-6
11.8
109
14400
10100
1-6T x 12F
12-72
12
6
1-6
11.8
113
14500
9400
8T x 12F
96
12
8
8
13.4
147
14200
9100
12T x 12F
144
12
12
12
16.4
211
14000
9200
Applications
Crush
[N/10 cm]
3000
ÆÆ
Duct & pole mount
ÆÆ
High tensile and crush performance
ÆÆ
Fully dielectric cable
ÆÆ
Self-supported aerial cable with aramid reinforcements
ÆÆ
UV resistant
Other fiber counts available on demand
Features
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Optical fibers
ÆÆ
Loose tube with filling compound (PBT Ø 2.5 mm)
ÆÆ
6-12 elements SZ stranded cable core
ÆÆ
Dry yarns to prevent moisture into cable
ÆÆ
Aramid yarns as tensile elements
Operating temperature
+100
+70°C
sag: 16.0 m
TRANSPORT
span: 800 m
+55°C
OPERATION
temperature [°C]
NESC Light
INSTALLATION
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
-15°C
-40°C
NSC Medium
span: 600 m
-100
sag: 12.0 m
NESC Heavy
span: 350 m
sag: 7.0 m
82 | telecom AERIAL AERO-AS14 2.5 mm
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
Special
Cable Designs
special design FTTA-DAC
special design FTTA-DAC
1
Cable structure
1.Outer jacket PE
2.Fiberglass yarns
3.Loose tube (PBT)
with colored fibers in filling gel
4.Ripcords
5.Embedded strength members (FRP)
2
5
3
4
FTTA
Hi-crush
Aerial
Compact design
Configuration
FTTA-DAC
Version
Fibers
Fibers per
tube
Ø
± 5%
[mm]
Nominal
weight
±10% [kg/km]
1T x 2F
2
2
5.8
31
1T x 4F
4
4
5.8
31
1T x 6F
6
1T x 8F
8
8
5.8
32
1T x 12F
12
12
5.8
32
1T x 24F
24
24
6.3
38
6
5.8
Max. tensile load [N]
installation
operation
800
(ε=0.33%)
31
Crush
[N/10 cm]
250
1200
(ε=0.50%)
3500
Applications
ÆÆ
Fiber to the antenna system ( FTTA)
ÆÆ
Optical access cable with fiber glass yarns
reinforcement
ÆÆ
Direct buried construction
ÆÆ
Fully dielectric cable
ÆÆ
Last mile connection
Features
Available colors
T-Telecom (according to IEC 60304) - Fibers
1
2
3
4
5
6
7
8
9
10
11
12
Code
Color
red
green
blue
white
violet
orange
grey
yellow
brown
pink
black
aqua
13-24
13
14
15
16
17
18
19
20
21
22
23
24
red
green
blue
white
violet
orange
grey
yellow
brown
pink
natural
aqua
Fiberglass yarns as water-blocking and strain relief
elements
ÆÆ
Loose tube (PBT) with filing compound
ÆÆ
Optical fibers
ÆÆ
Embedded strength members (FRP)
Operating temperature
Code
+100
+70°C
TRANSPORT
+50°C
OPERATION
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
temperature [°C]
Color
INSTALLATION
1-12
ÆÆ
-15°C
-45°C
-100
PE Black RAL 9005
84 | special design FTTA-DAC
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
hybrid power+fo
BDC-CIP 1.5 mm2
Cable structure
1.HDPE outer jacket
2.Fiberglass yarns
3.Loose tubes (PBT)
with colored fibers in
filling gel
4.Water blocking yarns
on FRP
hybrid cables BDC-CIP
1
5.Water blocking tape
6.Central strength member (FRP)
7.1.5 mm2 Cu – insulated
copper wire
8.Ripcord
2
3
5
4
7
6
Duct
FTTH
Basic Rodent
Protection
8
Hybrid FO
+ Power
Configuration
BDC-CIP 1.5 mm2
Version
Fibers
Fibers
Total
per
elements
tube
Active
tubes
Ø
± 5%
[mm]
Nominal
weight
±10%
[kg/km]
Max. tensile load
[N]
allowed
static
Applications
Crush
[N/10 cm]
ÆÆ
Installation into existing ducts
or directly buried
ÆÆ
High tensile and crush performance
1T x 12F
+2x1.5 mm2
12
12
6
1
10.7
127
2700
1300
1T x 12F
+4x1.5 mm2
12
12
6
1
10.7
170
2700
1300
2T x 12F
+1x1.5 mm2
24
12
6
2
10.7
107
2700
1300
2T x 12F
+2x1.5 mm2
24
12
6
2
10.7
128
2700
1300
ÆÆ
FRP strength and anti-buckling element
2T x 12F
+4x1.5 mm2
ÆÆ
Loose tube with filling compound (PBT Ø 2.2mm)
24
12
6
2
10.7
171
2700
1300
ÆÆ
Tubes with copper core
3T x 12F
+2x1.5 mm2
36
12
6
3
10.7
129
2700
1300
ÆÆ
Dry yarns to prevent moisture into the cable
ÆÆ
UV stabilized HDPE jacket
4T x 12F
+2x1.5 mm2
48
12
6
4
10.7
130
2700
1300
ÆÆ
LSOH, PA etc Jacket option
1T x 12F
+6x1.5 mm2
12
12
8
1
12.1
231
2700
1300
2T x 12F
+6x1.5 mm2
24
12
8
2
12.1
232
2700
1300
3T x 12F
+4x1.5 mm2
36
12
8
3
12.1
190
2700
1300
4T x 12F
+4x1.5 mm2
48
12
8
4
12.1
191
2700
1300
Technical copper wire characteristics
Max DC resistance
12,1±0,2 Ω/[email protected]°C
Electric strength
3400 V DC/1 minute
Current carrying capacity
7A
Operating voltage
65V AC/DC
Conductor material
Bare copper
PE Blackcross
RALsection
9005
Conductor
Operating temperature
+100
+70°C
TRANSPORT
OPERATION
+55°C
INSTALLATION
2700
temperature [°C]
Other fiber and copper wire counts available on demand
Features
-15°C
-40°C
-100
LSOH
1,5mm2Grey RAL 7022 LSOH Light Grey RAL 7037
Insulated conductor dia.
2,2mm
Insulation material
PVC
hybrid cables BDC-CIP | 85
hybrid power+fo
BDC-CIP 0.5 mm2 H05V-U
Cable structure
1.HDPE outer jacket
2.Fiberglass yarns
3.Loose tubes (PBT)
with colored fibers in
filling gel
4.Water blocking yarns
on FRP
hybrid cables BDC-CIP
1
5.Water blocking tape
6.Central strength member (FRP)
7.0.5 mm2 Cu – insulated
copper wire
8.Ripcord
2
3
5
4
7
6
Duct
FTTH
Basic Rodent
Protection
8
Hybrid FO
+ Power
Configuration
BDC-CIP 0.5 mm2 H05V-U
Max. tensile load
[N]
allowed
static
1T x 12F
+2x0.5 mm2
12
12
6
1
10.1
89
2700
1000
1T x 12F
+4x0.5 mm2
12
12
6
1
10.1
105
2700
1000
1T x 12F
+5x0.5 mm2
12
12
6
1
10.1
113
2700
1000
2T x 12F
+2x0.5 mm2
24
12
6
2
10.1
90
2700
1000
2T x 12F
+4x0.5 mm2
24
12
6
2
10.1
106
2700
1000
3T x 12F
+2x0.5 mm2
36
12
6
3
10.1
91
2700
1000
4T x 12F
+2x0.5 mm2
48
12
6
4
10.1
92
2700
1000
5T x 12F
+1x0.5 mm2
60
12
6
5
10.1
85
2700
1000
1T x 12F
+6x0.5 mm2
12
12
8
1
11.4
127
2800
1100
2T x 12F
+6x0.5 mm2
24
12
8
2
11.4
128
2800
1100
4T x 12F
+4x0.5 mm2
48
12
8
4
11.4
120
2800
1100
Other fiber and copper wire counts available on demand
Technical copper wire characteristics
Max DC resistance
36,0 Ω/[email protected]°C
Conductor material
Bare copper
Conductor cross section
0.5 mm2
Insulated conductor dia.
2.0 mm
Insulation material
PVC
[N/10 cm]
ÆÆ
For installation into existing duct or directly buried
ÆÆ
High tensile and crush performance
Features
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Insulated copper cores 0.5 mm2 (Ø 2.0 mm)
ÆÆ
Loose tubes with filling compound (PBT Ø 2.0
mm)
ÆÆ
Tape and dry yarns to prevent moisture into the
cable
ÆÆ
Fiberglass yarns as strain relief elements
ÆÆ
UV stabilized HDPE outer jacket
ÆÆ
Other outer jackets materials available
2700
Operating temperature
+100
+70°C
+55°C
-15°C
-40°C
-100
PE Black RAL 9005
86 | hybrid cables BDC-CIP
Applications
Crush
TRANSPORT
Nominal
weight
±10%
[kg/km]
OPERATION
Ø
± 5%
[mm]
INSTALLATION
Fibers
Active
tubes
temperature [°C]
Version
Fibers
Total
per
elements
tube
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
BDC-CIP 0.75 mm2 H05V-U
hybrid power+fo
Cable structure
1.HDPE outer jacket
2.Fiberglass yarns
3.Loose tubes (PBT)
with colored fibers in
filling gel
4.Water blocking yarns
on FRP
hybrid cables BDC-CIP
1
5.Water blocking tape
6.Central strength member (FRP)
7.0.75 mm2 Cu – insulated
copper wire
8.Ripcord
2
3
5
4
7
6
Basic Rodent
Protection
Duct
FTTH
8
Hybrid FO
+ Power
Configuration
BDC-CIP 0.75 mm2 H05V-U
Nominal
weight
±10%
[kg/km]
Max. tensile load
[N]
allowed
static
1T x 12F
+2x0.75 mm2
12
12
6
1
10.7
99
2700
1300
1T x 12F
+4x0.75 mm2
12
12
6
1
10.7
114
2700
1300
2T x 12F
+2x0.75 mm2
24
12
6
2
10.7
100
2700
1300
2T x 12F
+4x0.75 mm2
24
12
6
2
10.7
115
2700
1300
3T x 12F
+2x0.75 mm2
36
12
6
3
10.7
101
2700
1300
4T x 12F
+2x0.75 mm2
48
1T x 12F
+6x0.75 mm2
12
12
8
1
12.1
147
2700
1300
2T x 12F
+6x0.75 mm2
24
12
8
2
12.1
148
2700
1300
3T x 12F
+4x0.75 mm2
36
12
8
3
12.1
134
2700
1300
4T x 12F
+4x0.75 mm2
48
12
8
4
12.1
135
2700
1300
Applications
Crush
[N/10 cm]
ÆÆ
For installation into existing duct or directly buried
ÆÆ
High tensile and crush performance
Features
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Insulated copper cores 0.75mm2 (Ø 2.2mm)
ÆÆ
Loose tubes with filling compound (PBT Ø 2.2mm)
ÆÆ
Tape and dry yarns to prevent moisture into the
cable
ÆÆ
Fiberglass yarns as strain relief elements
ÆÆ
UV stabilized HDPE outer jacket
ÆÆ
Other outer jackets materials available
2700
6
4
10.7
102
2700
1300
Other fiber and copper wire counts available on demand
Technical copper wire characteristics
Max DC resistance
24.0 Ω/[email protected]°C
Conductor material
Bare copper
Conductor cross section
0.75 mm2
Insulated conductor dia.
2.2 mm
Insulation material
PVC
PE Black RAL 9005
Operating temperature
+100
+70°C
+55°C
INSTALLATION
12
TRANSPORT
Ø
± 5%
[mm]
OPERATION
Fibers
Active
tubes
temperature [°C]
Version
Fibers
Total
per
elements
tube
-15°C
-40°C
-100
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
hybrid cables BDC-CIP | 87
BDC-CIP 1.00 mm2 H05V-U
hybrid power+fo
Cable structure
1.HDPE outer jacket
2.Fiberglass yarns
3.Loose tubes (PBT)
with colored fibers in
filling gel
4.Water blocking yarns
on FRP
hybrid cables BDC-CIP
1
5.Water blocking tape
6.Central strength member (FRP)
7.1.0 mm2 Cu – insulated
copper wire
8.Ripcord
2
3
5
4
7
6
Basic Rodent
Protection
Duct
FTTH
8
Hybrid FO
+ Power
Configuration
BDC-CIP 1.0 mm2 H05V-U
Max. tensile load
[N]
allowed
static
1T x 12F
+2x1.00 mm2
12
12
6
1
10.7
104
2700
1300
1T x 12F
+4x1.00 mm2
12
12
6
1
10.7
124
2700
1300
2T x 12F
+2x1.00 mm2
24
12
6
2
10.7
105
2700
1300
2T x 12F
+4x1.00 mm2
24
12
6
2
10.7
125
2700
1300
3T x 12F
+2x1.00 mm2
24
12
6
2
10.7
125
2700
1300
4T x 12F
+2x1.00 mm2
48
12
6
4
10.7
107
2700
1300
5T x 12F
+1x1.00 mm2
60
12
6
5
10.7
98
2700
1300
1T x 12F
+6x1.00 mm2
12
12
8
1
12.1
162
2700
1300
1T x 12F
+6x1.00 mm2
12
12
8
1
12.1
162
2700
1300
2T x 12F
+6x1.00 mm2
24
12
8
2
12.1
163
2700
1300
3T x 12F
+4x1.00 mm2
36
12
8
3
12.1
144
2700
1300
3T x 12F
+4x1.00 mm2
36
12
8
3
12.1
144
2700
1300
4T x 12F
+4x1.00 mm2
48
12
8
4
12.1
145
2700
1300
Other fiber and copper wire counts available on demand
Applications
Crush
[N/10 cm]
ÆÆ
For installation into existing duct or directly buried
ÆÆ
High tensile and crush performance
Features
2700
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Insulated copper cores 1.00 mm2 (Ø 2.3 mm)
ÆÆ
Loose tubes with filling compound (PBT Ø 2.2
mm)
ÆÆ
Tape and dry yarns to prevent moisture into the
cable
ÆÆ
Fiberglass yarns as strain relief elements
ÆÆ
UV stabilized HDPE outer jacket
ÆÆ
Other outer jackets materials available
Operating temperature
+100
+70°C
+55°C
-15°C
-40°C
Technical copper wire characteristics
Max DC resistance
18.1 Ω/[email protected]°C
Conductor material
Bare copper
Conductor cross section
1.00 mm2
Insulated conductor dia.
2.3 mm
Insulation material
PVC
88 | hybrid cables BDC-CIP
-100
TRANSPORT
Nominal
weight
±10%
[kg/km]
OPERATION
Ø
± 5%
[mm]
INSTALLATION
Fibers
Active
tubes
temperature [°C]
Version
Fibers
Total
per
elements
tube
BDC-DIP 1.5 mm2 H07V-U
hybrid power+fo
Cable structure
1.HDPE outer jacket
2.Fiberglass yarns
3.Loose tubes (PBT)
with colored fibers in
filling gel
4.Water blocking yarns
on FRP
hybrid cables BDC-DIP
1
5.Water blocking tape
6.Central strength member (FRP)
7.1.5 mm2 Cu – insulated
copper wire
8.Ripcord
2
3
5
4
7
6
Basic Rodent
Protection
Duct
FTTH
8
Hybrid FO
+ Power
Configuration
BDC-DIP 1.5 mm2 H07V-U
Max. tensile load
[N]
allowed
static
1T x 12F
+2x1.5 mm2
12
12
6
1
12.4
137
2700
1500
1T x 12F
+4x1.5 mm2
12
12
6
1
12.4
166
2700
1500
2T x 12F
+2x1.5 mm2
24
12
6
2
12.4
138
2700
1500
2T x 12F
+4x1.5 mm2
24
12
6
2
12.4
167
2700
1500
3T x 12F
+2x1.5 mm2
36
12
6
3
12.4
140
2700
1500
4T x 12F
+2x1.5 mm2
48
12
6
4
12.4
141
2700
1500
5T x 12F
+1x1.5 mm2
60
12
6
5
12.4
128
2700
1500
1T x 12F
+6x1.5 mm2
12
12
8
1
14.2
228
3000
1800
2T x 12F
+6x1.5 mm2
24
12
8
2
14.2
229
3000
1800
3T x 12F
+4x1.5 mm2
36
12
8
3
14.2
202
3000
1800
4T x 12F
+4x1.5 mm2
48
12
8
4
14.2
203
3000
1800
Applications
[N/10 cm]
Other fiber and copper wire counts available on demand
Technical copper wire characteristics
Max DC resistance
12.1 Ω/[email protected]°C
Conductor material
Bare copper
Conductor cross section
1.5 mm2
Insulated conductor dia.
2.8 mm
Insulation material
PVC
PE Black RAL 9005
Crush
ÆÆ
For installation into existing duct or directly buried
ÆÆ
High tensile and crush performance
Features
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Insulated copper cores 1.50 mm2 (Ø 2.8 mm)
ÆÆ
Loose tubes with filling compound (PBT Ø 2.8
mm)
ÆÆ
Tape and dry yarns to prevent moisture into the
cable
ÆÆ
Fiberglass yarns as strain relief elements
ÆÆ
UV stabilized HDPE outer jacket
ÆÆ
Other outer jackets materials available
2700
Operating temperature
+100
+70°C
+55°C
TRANSPORT
Nominal
weight
±10%
[kg/km]
OPERATION
Ø
± 5%
[mm]
INSTALLATION
Fibers
Active
tubes
temperature [°C]
Version
Fibers
Total
per
elements
tube
-15°C
-40°C
-100
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
hybrid cables BDC-DIP | 89
BDC-DIP 2.5 mm2 H07V-U
hybrid power+fo
Cable structure
1.HDPE outer jacket
2.Fiberglass yarns
3.Loose tubes (PBT)
with colored fibers in
filling gel
4.Water blocking yarns
on FRP
hybrid cables BDC-DIP
1
5.Water blocking tape
6.Central strength member (FRP)
7.2.5 mm2 Cu – insulated
copper wire
8.Ripcord
2
3
5
4
7
6
Basic Rodent
Protection
Duct
FTTH
8
Hybrid FO
+ Power
Configuration
BDC-DIP 2.5 mm2 H07V-U
Max. tensile load
[N]
allowed
static
1T x 12F
+2x2.5 mm2
12
12
6
1
13.7
175
2800
1700
1T x 12F
+4x2.5 mm2
12
12
6
1
13.7
223
2800
1700
2T x 12F
+2x2.5 mm2
24
12
6
2
13.7
177
2800
1700
2T x 12F
+4x2.5 mm2
24
12
6
2
13.7
225
2800
1700
3T x 12F
+2x2.5 mm2
36
12
6
3
13.7
179
2800
1700
4T x 12F
+2x2.5 mm2
48
12
6
4
13.7
180
2800
1700
5T x 12F
+1x2.5 mm2
60
12
6
5
13.7
158
2800
1700
1T x 12F
+6x2.5 mm2
12
12
8
1
15.7
311
2800
1700
2T x 12F
+6x2.5 mm2
24
12
8
2
15.7
313
2800
1700
3T x 12F
+4x2.5 mm2
36
12
8
3
15.7
267
2800
1700
4T x 12F
+4x2.5 mm2
48
12
8
4
15.7
268
2800
1700
Other fiber and copper wire counts available on demand
Technical copper wire characteristics
Max DC resistance
7.41 Ω/[email protected]°C
Conductor material
Bare copper
Conductor cross section
2.5 mm2
Insulated conductor dia.
3.3 mm
Insulation material
PVC
90 | hybrid cables BDC-DIP
Applications
Crush
[N/10 cm]
ÆÆ
For installation into existing duct or directly buried
ÆÆ
High tensile and crush performance
Features
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Insulated copper cores 2.50 mm2 (Ø 3.3 mm)
ÆÆ
Loose tubes with filling compound (PBT Ø 3.2
mm)
ÆÆ
Tape and dry yarns to prevent moisture into the
cable
ÆÆ
Fiberglass yarns as strain relief elements
ÆÆ
UV stabilized HDPE outer jacket
ÆÆ
Other outer jackets materials available
2700
Operating temperature
+100
+70°C
+55°C
-15°C
-40°C
-100
TRANSPORT
Nominal
weight
±10%
[kg/km]
OPERATION
Ø
± 5%
[mm]
INSTALLATION
Fibers
Active
tubes
temperature [°C]
Version
Fibers
Total
per
elements
tube
hybrid power+fo BDC-DID 0.8 mm
Cable structure
1.HDPE outer jacket
2.Fiberglass yarns
3.Loose tubes (PBT)
with colored fibers in
filling gel
4.Water blocking yarns
on FRP
hybrid cables BDC-DID
3
5.Water blocking tape
6.Central strength member (FRP)
7.2x Ø 0.8/1.3 insulated
Cu pair
8.Ripcord
1
2
3
5
4
6
7
Basic Rodent
Protection
Duct
FTTH
8
Hybrid FO
+ Power
Configuration
BDC-DID 0.8 mm
1T x 12F +
7x2x0,8Cu
12
12
8
1
13.1
162
2T x 12F +
6x2x0,8Cu
24
12
8
2
13.1
161
3T x 12F +
5x2x0,8Cu
36
12
8
3
13.1
160
4T x 12F +
4x2x0,8Cu
48
12
8
4
13.1
158
5T x 12F +
3x2x0,8Cu
60
12
8
5
13.1
157
6T x 12F +
2x2x0,8Cu
72
12
8
6
13.1
156
7T x 12F +
1x2x0,8Cu
84
12
8
7
13.1
154
Max. tensile load
[N]
allowed
static
Applications
[N/10 cm]
2900
1900
Technical copper wire characteristics
PN-EN 50290-1-1:2002
Maximum resistance of wire loop
75 Ω/[email protected]°C
Insulation resistance
1500 MΩ·km
Material of conductor
Copper
Nominal diameter of conductor
0.8 mm
Nominal diameter of insulation
1.3 mm
Insulation material
PE
PE Black RAL 9005
ÆÆ
For installation into existing duct or directly buried
ÆÆ
High tensile and crush performance
Features
Other fiber and copper wire counts available on demand
Standard
Crush
2000
ÆÆ
FRP strength and anti-buckling element
ÆÆ
Insulated copper pairs 2xØ 0.8/1.3 mm
ÆÆ
Loose tubes with filling compound (PBT Ø 2.5
mm)
ÆÆ
Tape and dry yarns to prevent moisture into the
cable
ÆÆ
Fiberglass yarns as strain relief elements
ÆÆ
UV stabilized HDPE outer jacket
ÆÆ
Other outer jackets materials available
Operating temperature
+100
+70°C
+55°C
TRANSPORT
Nominal
weight
±10%
[kg/km]
OPERATION
Ø
± 5%
[mm]
INSTALLATION
Fibers
Active
tubes
temperature [°C]
Version
Fibers
Total
per
elements
tube
-15°C
-40°C
-100
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
hybrid cables BDC-DID | 91
NOTES
92 | fiber optic cables NOTES
NOTES
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
fiber optic cables NOTES | 93
NOTES
94 | fiber optic cables NOTES
NOTES
PE Black RAL 9005
LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
fiber optic cables NOTES | 95
FIBRAIN SP. Z O.O.
Rogoźnica 312
36-060 Głogów Małopolski
Poland
phone: (+48) 17 866-08-14
fax: (+48) 17 866-08-11
e-mail: [email protected]fibrain.com
FIBRAIN MÉXICO
Paseo de la Reforma 250 / Piso 9
Esquina c/Niza, Col. Juárez
Del. Cuahtémoc
México D.F. 06600
phone: (+52) 55 3600 7546
e-mail: [email protected]fibrain.com.mx
www.fibrain.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement