LRM2070, LRM2080, LRM2090 Datasheet OccuSwitch DALI sensor/controller 1/15 General description The OccuSwitch DALI is a combined sensor and controller. It will dim and switch on the lights in a room or area on occupancy and available daylight, with options for local override, parallel operation and network links to Building Management Systems (BMS). Savings of up to 75% can be achieved with functions like daylight depending dimming, occupancy control and over dimension correction. The OccuSwitch DALI is designed for an office area of 20 to 25 m2, or a classroom of around 40 m2 but the area can be doubled, or even tripled, with the extension sensor LRM8118. Up to 15 drivers (usually luminaires) can be controlled. A detachable wiring connector enables easy installation and mounting in the ceiling. Separate Wieland cables are available for an even easier, faster, trouble-free installation. It is possible to link up to 22 (advanced only) OccuSwitch DALI units in parallel to cover larger areas with a specific “open plan” mode to ensure maximum comfort and savings. The LRM2090 can be linked to most BMS or other control systems that have standard DALI interfaces (up to 64). This makes simple yet very effective control scenarios possible in a building. 2 52 80 95 LCC2070 cable set LN 7-pole STELVIO plug MRT3 P 5,08/07 V01 VE 7-pole STELVIO plug MRT3 P 5,08/07 V01 VE 500 52 mm 2 inch X DA X DA LN LCC2080 cable set le i2 ma BST14 Dimensions in mm GST18i3 BST14i2 female ale BST14i2 fem BST14i2 female GST18i3 60 mm 40 mm 60 mm Ø 95 mm The OccuSwitch DALI family exists of: LRM2070 Basic functionality LRM2080 Parallel operation LRM2090 DALI interface for BMS or other network LCC2070 Wieland cable for LRM2070 LCC2080 Wieland cable for LRM2080 and LRM2090 LRH2070 Ceiling mounting box LCU2070 Push-button Unit for 4 switches IRT9090 Extended IR programming tool LRM2070, LRM2080, LRM2090 Datasheet OccuSwitch DALI sensor/controller Applications 2/15 Typical applications The OccuSwitch DALI is designed for use in offices and similar applications like schools, including corridors, meeting rooms, etc. It is optimized for recessed ceiling mounting and for mounting heights between 2.5 and 4 meter. The surface box allows surface mounting as well, with either recessed wiring or surface-mounted ducts. The advanced OccuSwitch DALI can be connected in parallel (max 22) to cover larger areas like open plan offices. The use of different mains groups or even phases is no problem. Features LRM2070 Window/corridor and dynamic offset control For optimal energy savings the window and corridor luminaires are controlled separately as indicated in the graph. Window-side lights will switch off (or not switch on at entrance, the daylight override function) when sufficient daylight is available. The corridor side however will by default dim to minimum only, hence indicating to the user that the system is operational. This feature can be disabled. 100% 80% LRM2080 30% 1% max. offset Energy indicator The LED on the OccuSwitch DALI indicating movement or communication will change color depending on the energy usage. Dimming levels below 40% will show a green color, below 70% yellow, and above 70% red. LRM2090 LRM2080 LRM2070, LRM2080, LRM2090 Datasheet OccuSwitch DALI sensor/controller Function 1 Window 2 Corridor 3 Additional presence 4 Additional absence The additional luminaire groups can switch on together with the window and corridor groups or only switch on manually (absence). All groups will switch off when the area is vacated. Pre-programmed luminaires will be recognized upon start-up. Auto commissioning The OccuSwitch DALI can determine the installed lux level and take this as set point for the daylight depending regulation. This is easy to use without the need for a Lux meter. DALI network interface The LRM2090 can be controlled with a DALI network interface. This means that this device can be connected to most BMS or other control system with a DALI interface. This enables functions like switching on/ off, dimming, scenes and queries for lamp/driver states, the set light level and even more functions. With an specific gateway, supporting the OccuSwitch DALI BMS functions, it is also possible to use parallel occupancy control, very much like the OccuSwitch DALI advanced. Commissioning tool The OccuSwitch DALI can be commissioned with IRT9090 Extended IR programming tool. With this tool the light level can be set, walk test mode be started and window/corridor be assigned. The IRT9090 can also be used to set the desired mode, Start-up behavior, IR group and assign more luminaire channels. IRT9090 100 hours burn-in Many lamp manufacturers advise not to dim fluorescent lamps for a 100 hours period prior to normal use. Especially to maintain the light quality at (very) low dimming. The OccuSwitch DALI can do this automatically. During 100 hours lights will not be dimmed, and all dimming functions are disabled. Only during walk test (to test the installation) and commissioning dimming is allowed to make the necessary adjustments. Extension sensor The LRM8118 extension movement detector can be used to double the movement detection area. This sensor is connected to the same DALI channel as the luminaires. Installation is simple since mains is not required. Each LRM8118 connected counts as a driver on the DALI line. Ø 63.5 25.9 DALI group Walk test mode With the IRT9090 the walk test mode can be started. This makes it possible to check if the OccuSwitch DALI and the connected luminaires are correctly installed and fully operational, quick and easy. 2 DALI addressing The OccuSwitch DALI can be used with one channel only or two (window / corridor control), using the physical outputs (LRM2070 only). However all versions can be used with DALI addressing as well. Up to 4 groups can be defined. 3/15 Ø 72 Dimensions in mm LRM8118 extension sensor LRM2070, LRM2080, LRM2090 Datasheet OccuSwitch DALI sensor/controller 4/15 Push-button Unit The LCU2070 Push-button unit (PBU) makes it possible to connect up to 4 switches to the OccuSwitch DALI, to dim and switch different DALI groups. This PBU is connected to the DALI channel DA and/ or X for LRM2070 or DA only for LRM2080 and LRM2090. It derives its power form the DALI channel, so no additional power supply is required. The PBU uses the same interface technique as the one for Touch & Dim. Press briefly and it will switch on when off, and off when on. When pressed for a longer time, it will alternatively dim up and down. For all functions 1 0 click LCU2070 Push button interface 0 0 0 1 2 LRM8118 Extension sensor 0 1 2 2 2 Max. drivers per OSD 15 14 13 12 11 Smart Timer On some occasions with very little movement it is possible that the standard delay time of the OccuSwitch DALI is too short. If movement is detected during switch off (including fade this takes 10 seconds), the delay timer is automatically increased by 10 minutes. Detection area and shielding click press shortly 0 lights off 1 lights on 6m 4m 120° 5m 8m press longer 0 lights dim down 1 lights dim up Detection pattern Up to two PBUs can be used on a single OccuSwitch DALI. It is possible to interconnect (single) switches to several PBUs to control several OccuSwitch DALI units. Each LCU2070 connected counts as a driver on the DALI line. If the shield is retracted the detection pattern will be cut on one side (120°) as indicted in the diagram. The OccuSwitch DALI detection pattern (see drawing) is 4 by 5 meters for small movements (desk work) and 6 by 8 meters for larger movements like walking. We strongly suggest using the 4 by 5 meters for the design. It is also the right range for the Light Sensor (for daylight depending regulation). The detection area of the movement detector can be extended by two extension sensors (LRM8118) each with a equal detection pattern as the OccuSwitch DALI. LCU2070 Push-button unit Note: the LCU2070 requires the /10 (or higher) versions of the OccuSwitch DALI LCU2070/00 9137 003 35103 Made in E.U. PFT yyww LCU2070 wiring DA+ DA 1 2 3 4 5 6 DALI line on OccuSwitch DALI Black DA + Black DA - White COM Common Red SW1 (Window) Touch and Dim Purple SW2 (Window + Corridor + Extra Auto-on) Touch and Dim + Daylight Dependent Regulation White COM Common Green SW3 (Corridor) Touch and Dim Yellow SW4 (Extra Manual-on) Touch and Dim LRM2070, LRM2080, LRM2090 Datasheet OccuSwitch DALI sensor/controller LRM 2090 The BMS version has a second DALI interface (X connector). This interface makes it possible to connect the OccuSwitch DALI to a building management system using a controller or gateway with a DALI interface. The OccuSwitch DALI will act as a DALI slave. This also makes it possible to use DALI user interfaces to override the OccuSwitch DALI. This interface is fully compliant to DALI but the unit will act, of course, differently than a standard DALI driver. Response to DALI commands If a DALI command is received by the OSD BMS (for instance a direct arc power command) all luminaires in all groups connected to the OccuSwitch DALI will respond, and respond in the same way. The OccuSwitch DALI sends most of these DALI commands directly to the drivers (luminaires). Every command that changes the output level will disable the daylight depending regulation, and this is valid as long as there is motion. If there has been no motion for the set occupancy delay time (timer has run out), then the light will go on in daylight regulation mode. The daylight regulation is also enabled after sending a SCENE 1 command. Response to DALI queries The OccuSwitch DALI will respond to all DALI queries like a DALI (#102) driver. A query on the ACTUAL LEVEL will result in the average value of the window and corridor side. The OccuSwitch DALI performs a regular scan on the connected drivers. Queries on status and lamp failure will report the result of this scan, if a single driver reports an error, the OccuSwitch DALI will do as well. Other queries like MAX LEVEL will show the value and status as stored in the OccuSwitch DALI. Parallel mode The LRM2090 supports parallel mode. This means that units can work in parallel, very much like the advanced (LRM2080) version. Within one DALI channel a maximum of 64 OSD-BMS (LRM2090) can be connected and you can create 16 groups, and therefore 16 rooms or areas. Depending on the mode, each unit in a specific group will react on movement detected by itself or any other unit using the same group assignment. In all modes except mode 6 and 9 all units work in complete parallel. In mode 6, corridor linking is active and in mode 9, the smart open plan control is active (for more information on the different modes refer to page 11 and 12). When using OccuSwitch DALI BMS without a controller or gateway, either standalone or in groups, a DALI power supply (connected to the “X” bus) is required to enable communication between the OccuSwitches. 5/15 Smart open plan In mode 9, the LRM2090 will react differently to neighboring (so in the same group) occupancy detection. If the lights were off, lights will switch on, but at the so-called background level. Only if the unit itself detects occupancy, the light will it be set according to the predefined lightlevel. Daylight depending regulation is active in both situations. Only if none of the units detect occupancy (and each delay timer has elapsed) the lights will be switched off. Advanced functions for a BMS The LRM2090 can be connected to a standard DALI gateway as described earlier. To enable the advanced functions of the OccuSwitch DALI BMS, a specific gateway is required. There are 4 gateways that can be used: DALI <-> Lon (using LonMark) Loytec LDALI (LDALI-3E10x) with 1, 2 or 4 DALI channels DALI <-> BACnet Loytec LDALI (LDALI-ME204) with 4 DALI channels DALI <-> KNX Philips PDBC120-DALI-KNX with 1 DALI channel DALI <-> DyNet Philips Dynalite DDBC120-DALI-DyNet with 1 DALI channel The Loytec gateways need separate DALI power supplies. The different gateways offer different functionality. Integration with occupancy All gateways pass occupancy information from the OSD to other devices in the network (e.g HVAC and sunblinds). All gateways do this in groups, you cannot “see” an individual OSD sensor. Only groups of OSDs are visible, where either one, or more, or all, sensors are detecting occupancy. This is similar to the parallel mode (see earlier) and parallel operation is also active. This method reduces the amount of traffic on the bus and saves commissioning time for the building system, since only one connection needs to be made for a room or area. Compatibility All gateways come with all the necessary tools (the Loytec gateways even support off-line DALI commissioning) for the common integration tools like ETS, LNS™, LonMaker™ and Newron NL facilities™. The CEA-709 (Lon) gateway fully supports the LonMark standards. Exceptions • When SCENE 1 is sent to the Occuswitch DALI, it will begin daylight regulation using the predefined light level settings. • Any command resulting in a different output level will (re)start the occupancy timer. If you need to keep the lights on (or off) you need to repeat the command periodically with a shorter repeat time than the set occupancy timer. LRM2070, LRM2080, LRM2090 Datasheet OccuSwitch DALI sensor/controller 6/15 Addressing The OccuSwitch DALI supports the standard ways to address units. All address (including grouping) related commands are NOT relayed to the connected drivers. It is also possible to use the IRT9090 to set the address of the unit. This is only possible when the address has not been set before, or after a clear of the address by pressing two times 9 on the IRT9090 (which is confirmed by a blink of the connected lamps). Aim the IRT9090 at the OSD and within 5 seconds press the required 2 digit address on the numeric keypad, for instance 15 (press 1 and 5), or 05 (press 0 and press 5). The OccuSwitch DALI will blink its LEDs and connected lights to confirm the new settings. Corridor linking Units that are in mode 6 (corridor), will react to signals from its own group, but also from others. This creates the possibility to leave the lights on in the corridor if occupancy is detected in one of the adjacent rooms, even if the lights are switched off (manually or by daylight). 2 3 4 5 6 7 Energy calculator (Loytec gateways only) The gateway and OSD work together to form a beautiful energy calculation function. With very little commissioning, energy usage can be calculated. After commissioning, the OSD knows the number of luminaires it is controlling. It constantly records the dimming value (per DALI group, e.g. window and corridor), multiplies it by the number of luminaires, and adds this to the previously recorded values. The gateway collects this per BMS group but also per gateway channel. The gateway requests this value via either the BMS commissioning or the web interface. Note: this calculation can only be made if the same luminaires are used (but this is often the case in an office or school). HVAC and blind control (Loytec CEA-709 (Lon) only) These gateways support the use of a User Interface (UI). This UI is a Infrared communicating remote control that combines light, temperature setting, fan control and blind control in a single device. This is a perfect way to give the users the possibility to set the environment to their wishes and add flexibility (no wires needed), all at minimal costs. The UI is set according to the user’s wishes and needs, and therefore is only available in projects. 1 9 8 Note: The corridor group must also include all the other surrounding group numbers (e.g. 2, 3, 4, 5, 6, 7, 8 and 9). The group numbers mentioned here, sometimes referred to as BMS group number, can be configured through the gateway only and have no relation to DALI group numbers!! DisiplineFunction HVAC Temperature, Offset to setpoint Ventilation Fanspeed Blinds Movement Rotations Value -3, -2, -1, 0, +1, +2, +3 0, 33%, 66%, 100% Up, down, stop 15° up/down LRM2070, LRM2080, LRM2090 Datasheet OccuSwitch DALI sensor/controller 7/15 Mechanical installation The OccuSwitch DALI can be mounted in two ways; recessed in the ceiling or surface-mounted using the ceiling box. The ceiling box (LRH2070) has a breakout port for cable ducts and a breakout centerpiece. 1 2 80-82 mm 3 > 50 mm 3 ≤ 30 mm 4 1 2 LRH2070 LRM20xx Datasheet 5 max. 185 mm 4 LRM2070, LRM2080, LRM2090 Datasheet OccuSwitch DALI sensor/controller 8/15 Electrical installation The OccuSwitch DALI can be installed with either conventional wiring or Wieland connectors. For the second option, the Wieland cable (LCC2070 or LCC2080) is required. The OccuSwitch DALI comes with a detachable mains connector for easy installation. This connector is removed if the Wieland cable is used. The mains connection is protected by a retractable cover and secured with two tie wraps. The DALI signal from a driver or luminaire, although low voltage and isolated from mains, cannot be treated as a safe signal (SELV). All wiring and isolation materials used must be similar to mains wiring (FELV). The same applies to the network connection of the LRM2080 and LRM2090. LRM2070 2 1 – X + – DA + na N 3 L L N 4 5 LCC2070 or LCC2080 LRM2080 LRM2090 LRM2070, LRM2080, LRM2090 Datasheet OccuSwitch DALI sensor/controller 9/15 Commissioning Desired standard light level There are three ways to set the light level. Automated mode Step 1Press the OccuSwitch DALI button for 3 seconds until the LEDs start a yellow/green sequence Step 2Release and press again, the LEDs will now blink red/green Step 3Clear the area beneath the OccuSwitch DALI Step 4Within 10 seconds the auto calibration starts Lights will switch off and on to determine the installed lux level Lights will flash to indicate a successful operation The calibration is finished. Manual with normal control Step 1Use a remote or switch to set the desired light level Step 2Press the OccuSwitch DALI button until the LEDs start a yellow/green sequence Step 3Clear the area beneath the OccuSwitch DALI Step 4The light level existing 10 seconds after step 2 is used as set point Lights will flash to indicate a successful operation The calibration is finished. Delay time occupancy control With the rotary dial it is possible to select a time delay of 70s, or 5 to 30 minutes (in 5 minute increments). Further commissioning Using IRT9090 The OccuSwitch DALI will acknowledge commissioning commands by flashing the lights. The IRT9090 extended IR programming tool has a narrow beam to prevent that neigboring OccuSwitch DALI units are programmed by mistake. You must be within 17 meters of the device and aim exactly at it. Rotary Max. 17m = 1x IRT9090 Send command commissioning tool Luxmeter Calibrate light level Manual with IRT9090 Step 1Use the up and down keys to create the desired light level Step 2 Press the “SAVE” button Step 3The lights will flash once to indicate calibration was successful. LRM2070, LRM2080, LRM2090 Datasheet OccuSwitch DALI sensor/controller Settings done by IR remote. The following settings are sent all at once with the green SEND button. After selection of the function the red LED on the transmitter will switch on. Change IR group Both the OccuSwitch DALI and transmitters can operate in 7 different groups. Both the transmitter and OccuSwitch DALI must be in the same IR group. Select “group A-G” followed by the desired IR group (A-G, buttons 1 to 7). Change power-up behavior The OccuSwitch DALI switches the output on when it is connected to the mains. If the area is vacated, the lights will switch off after 5 minutes. It is possible to leave the output off and start movement detection 30 seconds after the mains is connected. Select “power up ON/OFF” followed by either “on” or “off ”. Restore defaults To restore the default settings, aim the IRT9090 towards the OccuSwitch DALI and press on “reset” and press SEND. Attention The IRT9090 will transmit all parameters when the SEND button is pressed. Error states The OccuSwitch DALI is designed to create (if possible) a safe situation if the device itself or its peripherals fail. Depending on the failure the OccuSwitch DALI will continue “as good as possible” or switch the lights on. The LED on the device will be always yellow and will not switch off, even if there is no movement or communication detected. Please refer to the manual of the OccuSwitch DALI for more information and diagnostic flow charts. Attention The OccuSwitch DALI should not be used in the following situations: • In applications outside the specification range, most notabley heights above 4 meter. • Environmental conditions other than in a normal office environment (temperature, humidity). • In applications with heat sources like electrical heaters, within the detection range of the device. • In applications with (semi-continuous) IR appliances like IRDA communication, IR communication between PDA and phones and other devices, headsets operating with IR communication, etc. Please note that some devices with IR communication send IR messages, even when there is no active communication link. These features must be disabled. • In applications with electronic drivers that operate up or near a frequency of 36Khz. Also when these drivers are not used in combination with the device, but the light from the lamps they operate is visible to the IR receiver. 10/15 LED Flash Red, Yellow or Green Circulation (long/short) Yellow/Green Red/Green Green/Red Movement or communication detected. Red = 100 – 70% Yellow = 70 – 40% Green = 40% - off Auto commissioning with current light level Auto commissioning DALI commissioning in progress Continuously Green (when lights are on) Yellow Red In 100 hours burn in mode (no dimming possible) Internal error Short circuit on DALI channel Fast sequence Red/Yellow/Green Trigger received from parallel unit (LRM2080 only) LRM2070, LRM2080, LRM2090 Datasheet OccuSwitch DALI sensor/controller 11/15 OccuSwitch DALI Modes The OccuSwitch DALI is set, by default, with a generic set of parameters for a standard office. But it is possible to recall 8 other application (specific cell, open plan or meeting room) modes as mentioned below. This makes the system very flexible for all different kinds of applications. With the aid of the extended IR programming tool IRT9090 specific modes can be selected. Once selected, the mode can be stored and copied via a point and shoot method. The mode will be stored in a nonvolatile memory. Even when the luminaires are switched off for a longer period, stored parameters are kept. The modes are compatible with the Actilume system’s modes, except for modes 4 and 5. Mode 1 Cell office Mode 6 Corridor Auto on Auto on Mode 2 Open plan office Auto on T1 T2 T1 T2 T1 T2 Mode 7 Toilets Auto on DDR off Mode 3 School, classroom Manual on Mode 4 Cell office Comfort mode EN 12464 Mode 5 Open plan office Comfort mode EN 12464 Mode 8 Meeting rooms Mode 9 ** Open plan Always light Auto on Mode 10 Open plan Comfort mode, always light Custom mode ** T his mode works differently for the advanced (LRM2080) and network (LRM2090) OSD when compared with OSD basic (LRM2070). For LRM2080 & LRM2090 the lights will switch off (the basic never switches off) when none of the advanced OccuSwitch DALI units in the parallel network detect movement. If one or more do detect movement, all other units will go to background level. Class room Cell office* Open plan* Corridor Toilets Meeting room Open plan office** Custom 3 4 5 6 7 8 9 10 0 10 10 10 N.a. 10 N.a. Infinite 0 15 60 0 0 0 120 N.a. Window only Disabled Disabled Window / corridor N.a. N.a. N.a. Window only N.a. Window / corridor Window / corridor Disabled Window / corridor Window / corridor Window / corridor Window / corridor Window / corridor Window / corridor N.a. Window only Window only Disabled Window / corridor Window only Window only Window / corridor Window only Window only N.a. Background lighting Local occupancy Local occupancy Local occupancy N.a. N.a. Local occupancy Local occupancy Local occupancy Daylight dependent Daylight dependent Parallel link period regulation switching (Advanced only) none of the advanced OccuSwitch DALI units in the parallel network detect movement. If one or more do detect movement, all other units will go to background level. * Equals mode 1 and 2, but without MD active. Do not use these modes for normal applications. ** T his mode works differently for the advanced (LRM2080) and network (LRM2090) OSD when compared with OSD basic (LRM2070). For LRM2080 & LRM2090 the lights will switch off (the basic never switches off) when N.a. Auto ON/OFF Manual ON/auto OFF 10 Auto ON/OFF Auto ON/OFF Disabled Disabled Manual ON/auto OFF 10 Auto ON/OFF 10 Open plan office Window only 2 0 10 Cell office (default) 1 Auto ON/OFF Smart timer Background period Daylight override (minutes) (minutes) Mode Application Occupancy LRM2070, LRM2080, LRM2090 Datasheet OccuSwitch DALI sensor/controller 12/15 LRM2070, LRM2080, LRM2090 Datasheet OccuSwitch DALI sensor/controller Safety The OccuSwitch DALI uses DALI or DALI-like signals to communicate to other devices, drivers or BMS systems. The interfaces (DA and X) on the OccuSwitch DALI have additional isolation from mains (SELV). However most DALI devices (like drivers in luminaires) only provide basic isolation between mains and DALI. Therefore to avoid installation safety issues, all interface wiring (also on the X-Interface) should be treated as FELV, so mains-rated isolation is required. We strongly recommend to always use cabling with mainsrated isolation to prevent potentially unsafe installations. Short circuit and protection The DA (all units) and X (LRM2070 and LRM2080) interface provides DALI (or other) power in order to be able to communicate. These interfaces are protected against a short circuit if used within specification. External power (DALI) supplies can only be used on the BMS DALI network of the LRM2090 (X-interface). The use of more than 22 LRM2080 units in parallel connected on the X-interface can damage the X-interface circuit. The network (X) interface of the LRM2090 has extended protection against mains connection. For all OccuSwitch DALI devices, the DA and X interface (except X-interface on LRM2090) will be damaged beyond repair if mains power is connected. Although safe, smoke and a strong smell can occur if this happens. Parallel mode The LRM2080 OccuSwitch DALI advanced supports parallel mode for occupancy control (X-interface). This means that the separate units have their own daylight-depending and local control and their own settings. Only the MD signal from connected units is shared. This means that lights will stay on if one of the connected systems detects movement. Lights will stay on and only switch off, or go to background level when the last MD timer in the group elapses. The exception to this rule is mode 9. The parallel link is refreshed every 60 seconds. So when movement is detected a signal will be given, then after 60 seconds repeatedly, until the timer elapses. This signal is visible on the unit. 13/15 LRM2070, LRM2080, LRM2090 Datasheet OccuSwitch DALI sensor/controller 14/15 Technical data Environmental conditions Storage conditions Temperature Relative humidity Operating conditions Temperature Relative humidity Mains connection Voltage Power consumption Connector screw terminal Wire range Mains distribution system Interfaces Parallel interface (LRM2080 only) BMS interface (LRM2090 only) DALI output interface Protocol Load capacity -25 ºC to +85ºC 10% to 95 %; no condensation +5ºC to +50ºC 20% to 85%; no condensation 230VAC +/10%; 50/60Hz Stand-by <1 W (without DALI load) Max. 1.7 W (with 15 drivers) MRT3P5.08-7VE or MVSTBW 2,5/7-ST-5.08 0.75 to 2.5 mm2 Note wires must be >= 0.75 mm2 TN-S, 16A max, with Neutral grounded Up to 22 units in parallel Free topology wiring and polarity sensitive DALI compatible Up to 64 units in parallel (depending on control device used as master) Free topology and polarity insensitive Bi-phase coded according to EN 60929 Ed 3.0 annex E Network polarity and polarity insensitive Maximum 15 DALI devices per output (for LRM2070 X+DA Interface) Protection Transmission rate DALI voltage Connector type General LED indicators Switch off delay Light levels Detection range Light sensor Interface is short-circuit proof Max. 1200 bits per second 11.5VDC to 21.5VDC Wieland BST 14i2; blue Standards Classification Pollution Over voltage Approbation Protection Class Flammability Glow wire test Insulation EMC Compliance IEC Immunity IEC Emission IEC EN 61347-2-11 Lamp control gear, Particular requirements for miscellaneous electronic circuits used with luminaires EN 60598-1 Luminaires, General requirements and tests Class I degree 2 category III Product complies with the relevant European Directive (CE) ENEC IP20 UL94 V-0 960°C/5s Supplementary insulation between Mains and SELV see text 1,5,10,15,20,25,30,35* minutes * IRT9090 only 250 to 1000 Lux (30% reflection) see detection pattern, page 4 see diagram, page 4 EN 61347-2-11 / EN 60598-1 EN 61547 EN 55015 and EN 55022, Class B LRM2070, LRM2080, LRM2090 Datasheet OccuSwitch DALI sensor/controller Packing data Type LRM2070 LRM2080 LRM2090 LCC2070 LCC2080 LRH2070 LCU2070 IRT9090 LRM8118 LRH8100 Dimensions (mm) 105 x 95 x 58 105 x 95 x 58 105 x 95 x 58 150 x 150 x 25 150 x 150 x 25 105 x 95 x 58 160 x 110 x 5 238 x 46 x 27 80 x 72 x 40 80 x 80 x 40 Ordering data Type MOQ LRM2070/30 Basic 1 LRM2080/30 Advanced 1 LRM2090/30 BMS 1 LCC2070/00 cable Basic 1 LCC2080/00 cable Adv + BMS 1 LRH2070/00 Surface Box 1 LCU2070/00 PBU 1 IRT9090/00 Extended IR programming tool 1 LRM8118/00 Extensions sensor 1 LRH8100/00 Sensor Surface Box Ext. Sensor 1 3222 636 33208 07/2014 Data subject to change www.philips.com/controls 15/15 Qty Material 1 1 1 1 1 1 1 1 1 1 cardboard cardboard cardboard plastic bag plastic bag cardboard plastic bag cardboard cardboard plastic bag Ordering number 9137 003 32904 9137 003 33004 9137 003 33103 9137 003 33703 9137 003 33803 9137 003 33903 9137 003 35103 9137 003 59103 9137 003 24703 9137 003 18903 EAN code level 1 8711559 732305 8711559 732343 8711559 732367 8711559 732480 8711559 732503 8711559 732527 8727900 870268 8718291 747635 8711559 730783 8711559 519203 Weight (Kg) net 0.12 0.12 0.12 0.13 0.13 0.05 0.16 0.105 0.07 0.02 EAN code level 3 8711559 732312 8711559 732350 8711559 732374 8711559 732497 8711559 732510 8711559 732534 8727900 870275 8718291 747642 8711559 730790 8711559 519210 gross 0.15 0.15 0.15 0.14 0.14 0.08 0.21 0.16 0.08 0.03 EOC 732305 99 732343 99 732367 99 732480 99 732503 99 732527 99 870268 00 747635 00 730783 99 519203 99
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement