VRF System

For more details, please contact our Carrier India sales office: 1800 3000 3545 Factory & Corporate Office: Carrier Airconditioning & Refrigeration Ltd, Kherki Daula Post, Narsingpur, Gurgaon 122004, Tel: 0124-4825500 Sales Offices:– Delhi/NCR: 0124-4707311/4707333 Ghaziabad: 0120-4183260 Lucknow: 0522-4158703/4158710 Chandigarh: 0172-5007549/ 5007550 Jaipur: 0141-5113444/5113999 Indore: 0731-4070378 Mumbai: 022-61700700 Ahmedabad: 079-44820400 Pune: 020-67045100 Kolkata: 033-40524354 Chennai: 044-66448888 Bangalore: 080-43442000 Hyderabad: 040-41100222 Cochin: 0484-4029001/0 This catalogue provides certain general information and is intended for general guidance only and Carrier is not liable for any damage arising out of the use of the catalogue. The Manufacturer reserves the right to change any product specification without prior notice. All Proprietary Rights Reserved Carrier July 2015 CIN: U74999HR1992FLC036104/ Website: www.carrierindia.com VRF System Developed to facilitate more flexible system design for big-sized buildings Carrier proudly introduces the X-Power VRF product, which is flexibly designed for a variety of applications/ occasions. Offering a higher capacity up to 72HP increments, it caters to all needs and requirements. It also incorporates numerous outstanding features, a range of large capacity outdoor units and indoor units, longer level difference and actual piping length and high external static pressure. The X-Power VRF product provides a flexible design and easy installation in big-sized and high-rise building for wide application. Contents 03 XPower VRF V4+K 23 XPower VRF V4+I Individual 26 XPower VRF V4+S Full DC Inverter 34 XPower Mini VRF 48 XPower Flexi Indoor Units 110 Control Devices 111 Control Systems 122 Accessories 01 02 VRF V4+ K Flexible Wide Application Range Two Modular VRF DC Inverter Outdoor Units Combination Flexi Modular Outdoor Units Lineup for Wide Range of Outdoor Units The Outdoor units capacity range is from 8HP up to 72HP in 2HP increment. Maximum 4 ( four ) outdoor units can be connected in one VRF System With maximum 64 indoor units with capacity up to 130% of the total outdoor units capacity. Two Modular VRF DC Inverter Outdoor Units can be connected with maximum quantity of 59 indoor units as per the below figure and table One Single Modular VRF DC Inverter Outdoor Unit One Single Modular VRF DC Inverter Outdoor Unit can be connected with maximum quantity of 29 indoor units as per the below figure and table 59 indoor units maximum 29 indoor units maximum 36 HP maximum capacity Two Modular DC Inverter Outdoor Units Combination 18 HP maximum capacity Two modular outdoor units combination One Single Modular DC Inverter Outdoor Unit One Single modular outdoor unit Total Capacity HP 8 10 12 14 16 18 03 8 HP One Single Modular Outdoor Unit 12 10 14 16 HP HP HP HP 18 HP Maximum quantity of indoor units 13 16 20 23 26 29 Total Capacity HP 18 20 22 24 26 28 30 32 34 36 8 HP Recommended two outdoor units combination 18 10 12 14 16 HP HP HP HP HP Maximum quantity of indoor units 20 33 36 39 43 46 50 53 56 59 04 Flexible Wide Application Range Flexi Modular Outdoor Units Lineup for Wide Range of Outdoor Units Four Modular VRF DC Inverter Outdoor Units Combination Three Modular VRF DC Inverter Outdoor Units Combination Three Modular VRF DC Inverter Outdoor Units can be connected with maximum quantity of 64 indoor units as per the below figure and table Four Modular VRF DC Inverter Outdoor Units can be connected with maximum quantity of 64 indoor units as per the below figure and table 64 indoor units maximum 64 indoor units maximum 72 HP maximum capacity 54 HP maximum capacity Four Modular DC Inverter Outdoor Units Combination Three Modular DC Inverter Outdoor Units Combination Three modular outdoor units combination Total Capacity HP 38 40 42 44 46 48 50 52 54 05 8 HP Recommended three outdoor units combination 18 10 12 14 16 HP HP HP HP HP Maximum quantity of indoor units 63 64 64 64 64 64 64 64 64 Four modular outdoor units combination Total Capacity HP 56 58 60 62 64 66 68 70 72 8 HP Recommended four outdoor units combination 18 10 12 14 16 HP HP HP HP HP Maximum quantity of indoor units 64 64 64 64 64 64 64 64 64 06 Flexible Wide Application Range Flexible Long Piping Length Wide Operation Range VRF DC Inverter system provides an actual total piping length of 1000 m, a maximum of 110 m between outdoor and indoor units. The height difference between outdoor units can be up to 8 m These generous allowances facilitate an extensive array of system design making VRF DC Inverter perfect for large projects. COOLING MODE Outdoor Temperature -20 Outdoor Temperature -10 0 10 27°C 20 30 40 50 60 Outdoor temp. °C(D.B.) Extra High Static Pressure – Max. 40Pa and Air Volume Increased by 10% - High-static pressure propeller and optimized fan guard can adapt to various installation environments. - Carrier now offers up to 40 Pa* external static pressure units for customized applications. - Standard 0-20Pa function is equipped by default. Level difference between IDU~IDU 30m -20°C 90m HEATING MODE Level difference between IDU~ODU 110m 48°C Longest piping actual length 175m -5°C 40 Pa The first indoor unit branch * You need to consult Carrier sales team if you require over 40Pa external static pressure . Permitted value Total piping length*1 (Actual) Piping length 1000m Actual length 175m Equivalent length 200m Longest piping (L) Piping (The farthest IDU from the first Indoor unit branch) equivalent length Level difference Outdoor unit up 70m Outdoor unit down 110m Level difference between IDU~ODU Level difference between IDU~IDU 07 40m/90m*2 30m *1 Total pipe length is equal to two times pipe length plus pipe length. *2 When the farthest pipe length is more than 40m. It needs to meet the specific conditions according to the installation manual. 08 Advanced Technologies DC Inverter Scroll Compressor High Efficiency and Super Quiet DC Fan Motor For VRF ECO DC Inverter – Modular Outdoor Units 8HP and 10HP models are equipped with one DC inverter compressor 12, 14, 16, 18 HP models are equipped with one DC inverter compressor and one fixed frequency compressor. According to the running load and pressure, it controls the speed of DC fan n motor to achieve the minimum power consumption. Suction Pipe Discharge Pipe For VRF ECO DC Inverter – Modular Outdoor Units 8HP and 10HP models are equipped with one DC fan motor 12, 14, 16, 18 HP models are equipped with two DC fan motor. New structure enhances, mid frequency performance Used across entire range of models (from 8 to 72 HP). Specially designed scroll profile for R410A Wide speed adjustment with 18 steps vector control. Efficiency improvement up to 45% especially at low speed. DC fan motor More compact, weight reduced by 50% Advanced permanent magnet DC motor provide high torque and efficiency and achieve 70% reduction in volume. Oil even Pipe Fan Speed Control 18 steps vector control 100 High Wide operation range from 20Hz to 200Hz. Low DC Inverter Scroll Compressor 80 EFFICIENCY (%) High IPLV Increased by 45% 60 40 20 200 1000 MOTOR SPEED (RPM) High Efficiency / Super Quiet Fan Housing and Outlet Grille Compressor efficiency Efficiency-Rotor Speed Curve Centralizing winding New DC motor-centralized winding Distributing winding Common DC motor-distributing winding Optimum design of fan housing and outlet grille for minimum airflow resistance, maximum air flow, minimum sound level and minimum vibrations. Efficient Air Management System (AMS) with uniform air circulation over the complete e coil surface at low velocity for maximum efficiency and minimum sound level. High Efficiency and Super Quiet Outdoor Fan (s) Rotor speed(s-1) 20 40 60 80 100 Smooth 180°sine wave DC Inverter By adoption of the 180°SineWave Inverter which smooths the rotation of the compressor motor, and improves compressor efficiency sharply than traditional sawtooth wave. Optimum design of 3-dimensional turbo fan with patent aerodynamic new profile design of fan blades with sharp edge and little curve bigger diameter for minimum airflow resistance, maximum airflow, minimum sound and minimum vibrations. Common design Carrier design New Fan Arrangement Technology for Sound Reduction Common sawtooth wave 09 Capacity 8 / 10 HP Fan Qty. 1 12 / 14 / 16 / 18 HP 1+1 180° Sine Wave DC inverter 10 High Efficiency High Efficiency Heat Exchanger High EER / High COP Values Common design Relative windage resistance Carrier design VRF ECO DC Inverter Series with all high efficiency DC Inverter scroll compressors all, DC motors and high efficiency heat exchanger, achieve the world’s Top Class energy efficiency. Cooling EER up to 4.29 and Heating COP up to 4.39 in the 8HP category. COP 4.29 3.89 3.70 3.25 3.21 3.29 4.39 4.14 4.17 4.02 18HP 0.6 0.4 Common design Reduce 28% 0.2 0 3.93 High efficiency inner-threaded pipe, enhance heat transfer. 8HP 10HP 12HP 14HP 16HP 0.8 Carrier design 0 3.91 8HP 10HP 12HP 14HP 16HP 18HP Relative windage resistance EER Windage& air flow 200 400 600 800 1000 Re Frost contrast 0.8 Reduce 30% Common design 0.6 0.4 Carrier design 0.2 0 0 0.2 0.4 0.6 0.8 1 Relative frosting rate Hydrophilic film fins + inner-threaded pipes The new designed window fins enlarge the heat-transfer area , decrease the air resistance, save more power and enhance heat transfer performance in cooling and heating. Hydrophilic aluminum fins and inner-groove copper tubes optimize heat transfer efficiency. Multi solenoid valves control technology Multi solenoid valves control technology and double EEV control technology in one VRF system. All the solenoid valves equipped in the unit ensure temperature-control precisely, system running steadily and economic to provide a comfortable environment. Common design Gas Liquid Carrier design Gas Gas Liquid Gas Gas-Liquid Liquid Liquid Common Design Sub-cooling Technology Increase the hot liquid rate in the condenser Improve the heat-exchange efficiency Innovative designed high efficiency heat exchanger, which can reach up to 12oC subcooling degree, reduces the system resistance and improves reliability. When the outdoor temperature is 35oC, the refrigerant can be cooled down to 37.1oC, thus achieving high heat-transfer efficiency with only 2.1oC temperature difference. High pressure sensor Controls the discharge pressure of the compressor and to control the fan speed. Always test the system pressure 11 Every 20 seconds, compare the system pressure and the best pressure to adjust DC fan motor speed timely. 12 High Efficiency VRF DC Inverter Outdoor Unit Night Silent Operation Mode For Super Silent Operation Carrier Night Silent Mode feature which is easily set on the main board allows the unit to be set to various time options during Non Peak and Peak operation time optimizing the units sound output. High efficiency & super quiet Fan housing and outlet grill Super silent operation mode can reduce sound level further, minimum 45 dB (A). Night silent operation will be activated X hours after the peak temperature during daytime, and it will go back to normal operation after Y hours. 0RGHOĺ;KRXUV<KRXUV0RGHOĺ;KRXUV<KRXUV 0RGHOĺ;KRXUV<KRXUV0RGHOĺ;KRXUV<KRXUV Noise dB Load % Capacity % High efficiency & super quiet Outdoor fan (s) High efficiency & super quiet DC fan motor Peak value of ambient temp. 100 50 10hrs 8hrs Night silent Mode noisc Max.-10dB(10Hp) Start 08:00 14:00 Notes: This function can be activated by setting at site. 22:00 End 08:00 Temperature(load) curve shown in the graph is just an example. Intelligent Defrost Extends Comfortable Time & Increase Heat Capacity High efficiency 180°sine-wave DC inverter control ol For compressor motor defrost For smooth rotation of compressor motor and high efficiency of compressor motor. High efficiency outdoor coil High efficiency & super quiet DC Inverter Scroll compressor Oil Separator Outlet Accumulator Liquid Receiver Inlet Inlet Outlet Oil balance High efficiency & super quiet Fixed frequency Scroll compressor(s) Only for VRF ECO DC Inverter outdoor unit. Oil return t Efficient Refrigerant Compressor 13 14 High Reliability Back-up Function Duty Cycling Function In one combination of VRF ECO DC inverter - modular outdoor units, any outdoor unit can run as the master outdoor unit to equalize the service life of all outdoor units. Master Outdoor Unit Slave (1) Outdoor Unit Slave (2) Outdoor Unit In one combination of VRF ECO DC inverter – modular outdoor units, when the master outdoor unit failed, any single slave outdoor unit can be set as the master unit, then the remaining outdoor units can keep on working. This can be set at field by DIP switch located on the main board of electrical control box of outdoor unit. Master Outdoor Unit VRF ECO DC inverter INV FIX INV FIX INV Slave (1) Outdoor Unit Slave (2) Outdoor Unit VRF ECO DC inverter FIX INV FIX INV INV FIX FIX When the slave (1) outdoor unit failed and came into standby state, the left module still work. 12HP - 14HP - 16HP - 18HP models with two compressors have an alternative cycle duty function High efficiency oil balance and oil return technology Indoor Unit Quantity Monitoring 2nd stage 4th stage The quantity of indoor units should be exactly set on the outdoor main board, once some indoor units miscommunicate with outdoor units during system running, the outdoor units will stop and display the fault code “H7”. This can prevent compressor from liquid hammer caused by dropped indoor units with EXV unclosed. ENC3 S12 ON 5th stage 1st stage Quantity setting switch 3rd stage Easy Installation, Service and Maintenance Compact Design for Effective Use of Space 5 stage oil control technology ensures every outdoor unit & compressor’s oil always keep in the safe level, completely solve the compressor oil lack problem. 1st stage: compressor internal oil separate 2nd stage: high efficiency oil separator (separation efficiency up to 99%) 3rd stage: oil balance technology between compressors 4th stage: oil balance technology between modules 5th stage: intelligent system oil return program 15 Easy to transport VRF DC Inverter system's indoor and outdoor units are easy in installation, service and maintenance. Compact size and light weight design minimizes the installation footprint, reduces the installation floor load, and is easier for transportation. For some projects the units can even be transported through the elevator or forklift, reduce access problem at the jobsite and reduce time and labor. 16 Auto Addressing of Indoor Units Easy Service and Maintenance Through Wireless Remote Control Reserved checking window on electric control box for convenient spot checking and status enquiry. Through Outdoor Unit Wireless remote control can query and modify Outdoor unit can automatically distribute the each indoor unit's address. addresses to indoor units. Self-diagnosis function helps service engineers to locate faults quickly and easily. Remote addressing Compressor is located near the door, which simplifies checks and enables valve or compressor parts to be replaced easily. Simple Signal Line Connection Installation is easier as communication wiring can be shared by indoor & outdoor units . It's easy for the user to retrofit the existing system with a centralized control by simply connecting to the outdoor units. PQ E XY E PQ E X Y E P Q E PQE & XYE: only one set of PQE signal wires can achieve communication among indoor units, outdoor units and the network. Reversible communication, central controller can be connected from indoor side or outdoor side as you wish. PQ E PQ E Wireless controller can query and modify each indoor unit's address. Various locking modes enhance convenience for users In VIP priority or vote priority mode, the address of the VIP unit should be set as 63, if there is no 63 unit, it will respond to vote priority. ,ĞĂƟŶŐ ĂƟŶŐ priorityy mode (default) fault) 17 ŽŽůŝŶŐ ŽůŝŶŐ priorityy mode VIP priority riority or vote priority ority KŶůLJƌĞƐƉŽŶĚ ƚŚĞŚĞĂƟŶŐ mode KŶůLJƌĞƐƉŽŶĚ ƌĞƐƉŽŶĚ ŽŽůŝŶŐ ƚŚĞĐŽŽůŝŶŐ mode ode 18 MODULAR OUTDOOR UNITS – V4+K improve TM buildings Outdoor Unit Model Power supply 12 HP 8 HP - 10 HP Technical specifications 38VR008H1190K1 38VR010H1190K1 Outdoor Unit Model 38VR012H1190K1 38VR014H1190K1 Power supply 380 ~ 415 - 3 ~ 50 V-Ph-Hz kW 25.2 28 33.5 Btu/h 85,982 95,536 114,302 Input kW 5.9 7.2 9.1 EER W/W 4.29 3.89 3.70 kW 27 31.5 37.5 Btu/h 92,124 107,478 127,950 Input kW 6.15 7.6 9.0 COP W/W 4.39 4.14 4.17 Capacity 1 1 1+1 kW 40 45 50 Btu/h 136,480 153,540 170,600 Input kW 12.3 14.0 15.2 EER W/W 3.25 3.21 3.29 kW 45 50 56 Btu/h 153,540 170,600 191,072 12.8 14.3 4.02 3.91 3.93 1+1 1+1 1+1 DC Inverter + Fixed Frequency DC Inverter + Fixed Frequency DC Inverter + Fixed Frequency 1+1 1+1 1+1 Cooling(*1) Heating(*1) DC Inverter DC Inverter DC Inverter + Fixed Frequency Outdoor Fan Motor Quantity 1 1 1+1 Outdoor air flow m3/h 11500 11500 15100 Outdoor sound pressure(*2) dB(A) 57 57 59 Dimension(W*H*D) mm 960*1615*765 960*1615*765 1250*1615*765 Packing (W*H*D) mm 1025*1790*830 1025*1790*830 1305*1790*825 Net/Gross weight Kg 200/215 200/215 268/288 Gas Ø 25.4 Ø 25.4 Ø 31.8 Liquid Ø 12.7 Ø 12.7 Ø 15.9 Outdoor unit Refrigerant Piping Lines (*3) 1.Nominal conditions Outdoor Indoor o o o o 35 C DB (95 F) o 7 C DB (42.8 F) Cooling 27 C DB (80.6 F), 19 C WB (60 F) Heating 20 C DB (68 F), 15 C WB (44.6 F) o o o Pipe length o o Level difference o 7.5m 0m o 7.5m 0m Capacity Input kW COP W/W 11.2 Quantity Compressor Type Compressor Type 38VR018H1190K1 380 ~ 415 - 3 ~ 50 Capacity Heating(*1) Quantity 18 HP 38VR016H1190K1 V-Ph-Hz Capacity Cooling(*1) 14 HP - 16 HP Technical specifications Outdoor Fan Motor Quantity Outdoor air flow m3/h 15100 15100 15250 Outdoor sound pressure(*2) dB(A) 60 60 61 Dimension(W*H*D) mm 1250*1615*765 1250*1615*765 1250*1615*765 Packing (W*H*D) mm 1305*1790*825 1305*1790*825 1305*1790*820 Net/Gross weight Kg 280/300 280/300 300/320 Gas Ø 31.8 Ø 31.8 Ø 31.8 Liquid Ø 15.9 Ø 15.9 Ø 19.1 Outdoor unit Refrigerant Piping Lines (*3) 1.Nominal conditions Outdoor Indoor o o o 35 C DB (95 F) o 7 C DB (42.8 F) 27 C DB (80.6 F), 19 C WB (60 F) Heating 20 C DB (68 F), 15 C WB (44.6 F) o o o Pipe length o Cooling o o Level difference o 7.5m 0m o 7.5m 0m 2.Sound level: Anechoic chamber conversion value, measured at a position 1m in front of the unit and 1.5m above the floor. 3.Refrigerant pipe dim.listed here only for when the total equivalent length <90m. For the data when total quivalent length 90 m please refer to technical manual. 2.Sound level: Anechoic chamber conversion value, measured at a position 1m in front of the unit and 1.5m above the floor. 3.Refrigerant pipe dim.listed here only for when the total equivalent length <90m. For the data when total quivalent length 90 m please refer to technical manual. 19 20 Outdoor Unit dimensions ( Unit : mm ) Outdoor unit - Installation dimensions (Unit: mm) Outdoor Unit 12/14/16/18 HP 1615 1615 8/10 HP ĭ([SDQVLRQEROW Rubber shocking proof mat 960 765 1250 765 Concrete basement h=200mm Solid ground or roofing 200mm Refrigerant Piping Connections ( Unit : mm ) Screw Bolt Position B Liquid side A B A Gauge point Cooling only type without Oil balancer C D For parallel connect the modular units Gas side HP 8/10 12/14/16/18 A 830 1120 B 960 1250 C 736 736 D 765 765 F E D SIZE 15×23 long u-shape hole C R: Pipe Connection R Section View 8 10 12 14 16 18 A 199 199 169 169 169 169 B 159 159 209 209 209 209 C 195 195 169 169 169 169 D 168 168 168 168 168 168 (4) Ensure that the outdoor unit is installed in a cool place without direct sunshine exposure or direct radiation of high-temp heat source. E 208 208 208 208 208 208 (5) Do not install the outdoor unit in a dirty or severely polluted place, so as to avoid blockage of the heat exchanger in the outdoor unit. 220 220 220 220 (6) Do not install the outdoor unit in a place with oil pollution or full of harmful gases such as sulfurous gas. 2'ĭ 2'ĭ 2'ĭ 2'ĭ 2'ĭ 2'ĭ 2'ĭ 2'ĭ F 220 220 Liquid pipe 2'ĭ 2'ĭ Gas pipe 21 Notes: (1) Ensure that the outdoor unit is installed in a dry, well-ventilated place. HP SIZE 2'ĭ 2'ĭ (2) Ensure that the noise and exhaust ventilation of the outdoor unit do not affect the neighbors of the property owner or the surrounding ventilation. (3) Ensure that the outdoor unit is installed in a well-ventilated place that is possibly closest to the indoor unit. (7) Do not install the outdoor unit in a place surrounded by salty air. (Except for the models with corrosion-resistant function.) 22 VRF V4+ I Individual FLEXIBLE LONG PIPING LENGTH DESIGN LAYOUT VRF DC Inverter system provides an actual total piping length of 1000 m, a maximum of 110 m between outdoor and indoor units. The height difference between indoor units can be up to 30 m Top discharge These generous allowances facilitate an extensive array of system design making VRF DC Inverter perfect for large projects. 2 Pipe system Individual design 20HP Space saving 22HP - 24HP 26HP-32HP Integrated design of individual outdoor unit saves the installation distance between two modular outdoor units to reduce the area. Simple and easy arrangement of piping inside the individual outdoor unit Ambient temperature range – Cooling is -5°C ~ 48°C Ambient temperature range – Heating is -20°C ~ 27°C New designed grille reduces the wind resistance and increase the New designed fan shape decreases the noise. Fig. Individual outdoor unit 30HP ( Example ) 90m Total capacity % range of indoor units is 50% ~ 130% Longest piping actual length 175m to facilitate installation, service and maintenance. see fig. Level difference between IDU~IDU 30m Level difference between IDU~ODU 110m Simple installation with less at site works and less installation cost Table : Individual Outdoor units lineup – individual type One single individual outdoor unit Capacity HP Maximum quantity of indoor units 20 33 22 36 24 39 The first indoor unit branch Permitted value 1 Total piping length* (Actual) Piping length 26 43 28 46 50 32 53 Actual length 175m Equivalent length 200m Longest piping (L) Piping (The farthest IDU from the first Indoor unit branch) equivalent length Level difference 30 1000m Outdoor unit up 70m Outdoor unit down 110m Level difference between IDU~ODU Level difference between IDU~IDU 23 40m/90m*2 *1 Total pipe length is equal to two times pipe length plus pipe length. *2 When the farthest pipe length is more than 40m. It needs to meet the specific conditions according to the installation manual. 30m 24 INDIVIDUAL OUTDOOR UNITS – V4+I VRF V4+ S Full DC Inverter DESIGN LAYOUT Top discharge 2 Pipe system Modular design 6 basic modules, which can freely be combined in the installation site for wide range Outdoor Unit Model Power supply and large capacity for big sizes buildings. 20 HP - 32 HP P P Technical specifications 2HP increment of capacity range, which meets customers needs accurately. 38VR020H119013 38VR022H119013 38VR024H119013 38VR026H119013 38VR028H119013 38VR030H119013 38VR032H119013 V-Ph-Hz kW 56 61.5 67 73.0 78.5 85.0 90.0 Btu/h 191072 209838 228604 249076 267842 290020 307080 Input power kW 17.0 18.8 20.8 22.3 24.2 26.5 28.1 EER W/W 3.29 3.27 3.22 3.27 3.24 3.20 3.20 kW 63 69 75 81.5 87.5 95 100 Btu/h 215017 235494 255973 278157 298635 324232 341297 Input power kW 16.0 17.9 19.8 20.6 22.4 25.0 26.5 COP W/W 3.94 3.85 3.79 3.96 3.91 3.80 3.77 1+2 1+2 1+2 1+3 1 +3 1+ 4 1+4 Capacity Cooling (*1) Outdoor unit with all DC Inverter Compressor (s) + all DC fan motor (s) 380~415V-3Ph-50Hz Capacity Heating (*1) Outdoor Unit ( Module ) Compressor Quantity DC Inverter Compressor (1) DC Inverter Compressor (2) Outdoor Fan Motor Quantity DC Fan Motor 8 HP 10 HP 12 HP 14 HP 16 HP 1 1 1 1 1 1 1 1 1 1 2 2 2 18 HP 1 1 2 Maximum capacity is 72 HP Maximum quantity of outdoor units is 4 Quantity Compressor Maximum quantity of indoor units is 64 DC Inverter + Fixed Frequency (High Efficiency Scroll) Type Maximum quantity of connected indoor units 33 36 39 43 46 50 m3/h 20000 23000 23000 Outdoor sound level (*2) dB(A) 62 63 63 Dimension (W*H*D) mm 1390*1615*765 1585*1615*765 2540 x 1615 x 765 Packing (W*H*D) mm 1455*1790*830 1650*1810*840 2600 x 1800 x 825 Net/ Gross weight Kg 360 / 375 Liquid mm ĭ ĭ Gas mm ĭ ĭ Refrigerant (*3) Piping Lines 53 56~72 HP Outdoor air flow Outdoor unit Total capacity % range of indoor units is 50% ~ 130% 33100 64 64 65 65 38~54 HP 385 / 400 390 / 405 555/590 555/590 20~36 HP 600/635 600/635 8~18 HP 1.Nominal conditions Outdoor Indoor o o o 35 C DB (95 F) o 7 C DB (42.8 F) 27 C DB (80.6 F), 19 C WB (60 F) Heating 20 C DB (68 F), 15 C WB (44.6 F) o o o Pipe length o Cooling o o Level difference o 7.5m 0m o 7.5m 0m 2.Sound level: Anechoic chamber conversion value, measured at a position 1m in front of the unit and 1.5m above the floor. 3.Refrigerant pipe dim.listed here only for when the total equivalent length <90m. For the data when total quivalent length 90 m please refer to technical manual. 25 26 FEATURES FLEXIBLE WIDE APPLICATION RANGE Flexible long piping length VRF DC Inverter system provides an actual total piping length of 1000 m, a maximum of 110 m between outdoor and indoor units. The height difference between outdoor units can be up to 8 m These generous allowances facilitate an extensive array of system design making VRF DC Inverter perfect for large projects. Wide operation range COOLING MODE Outdoor Temperature -20 Outdoor Temperature -10 0 10 27°C 20 30 40 50 60 Outdoor temp. °C(D.B.) VRF Full DC Inverter system operates stably at extreme outdoor temperature range from -5°C to 52°C in cooling and from -20°C to 27°C in heating. Level difference between IDU~IDU 30m -20°C 90m HEATING MODE Level difference between IDU~ODU 110m 52°C Longest piping actual length 175m -5°C Extra high static pressure – max. 40Pa and air volume increased by 10% - High-static pressure propeller and optimized fan guard can adapt to various installation environments. - Carrier now offers up to 40 Pa* external static pressure units The first indoor unit branch 40 Pa for customized applications. Permitted value - Standard 0-20Pa function is equipped by default. Total piping length*1 (Actual) Piping length * You need to consult Carrier sales team if you require over 40Pa 1000m Actual length 175m Equivalent length 200m Longest piping (L) external static pressure . Piping (The farthest IDU from the first Indoor unit branch) equivalent length Level difference 40m/90m*2 Outdoor unit up 70m Outdoor unit down 110m Level difference between IDU~ODU Level difference between IDU~IDU 30m *1 Total pipe length is equal to two times pipe length plus pipe length. *2 When the farthest pipe length is more than 40m. It needs to meet the specific conditions according to the installation manual. 27 28 High efficiency heat exchanger Common design Relative windage resistance Carrier design HIGH EFFICIENCY Windage& air flow 0.8 0.6 High EER / High COP values 0.4 Common design Reduce 28% 0.2 Carrier design 0 High efficiency inner-threaded pipe, enhance heat transfer. Relative windage resistance 0 200 400 600 800 1000 Re VRF FULL DC Inverter Series with all high efficiency DC Inverter scroll compressors all, DC motors and high efficiency heat exchanger, achieve the world’s Top Class energy efficiency. Cooling EER up to 4.29 and Heating COP up to 4.39 in the 8HP category. Frost contrast 0.8 Reduce 30% Common design 0.6 0.4 Carrier design 0.2 EER COP 4.29 3.97 3.81 3.54 3.40 3.38 4.39 4.17 4.17 4.02 3.91 3.89 0 0 0.2 0.4 0.6 0.8 1 Relative frosting rate Hydrophilic film fins + inner-threaded pipes The new designed window fins enlarge the heat-transfer area, decrease the air resistance, save more power and enhance heat transfer performance in cooling and heating. 8HP 10HP 12HP 14HP 16HP Hydrophilic aluminum fins and inner-groove copper tubes optimize heat transfer efficiency. 18HP 8HP 10HP 12HP 14HP 16HP 18HP Common design Gas Liquid Carrier design Gas Gas Multi solenoid valves control technology Liquid Gas Gas-Liquid Liquid Liquid Common Design Sub-cooling Technology Increase the hot liquid rate in the condenser Improve the heat-exchange efficiency Multi solenoid valves control technology and double EEV control technology in one VRF system. All the solenoid valves equipped in the unit ensure temperature-control precisely, system running steadily and economic to provide a comfortable environment. Innovative designed high efficiency heat exchanger, which can reach up to 12oC subcooling degree, reduces the system resistance and improves reliability. When the outdoor temperature is 35oC, the refrigerant can be cooled down to 37.1oC, thus achieving high heat-transfer efficiency with only 2.1oC temperature difference. High pressure sensor Controls the discharge pressure of the compressor and to control the fan speed. Always test the system pressure 29 Every 20 seconds, compare the system pressure and the best pressure to adjust DC fan motor speed timely. 30 MODULAR OUTDOOR UNITS – V4+S Technical specifications 12 HP 8 HP - 10 HP Outdoor Unit Model 38VF008H119010 38VF010H119010 38VF012H119010 V-Ph-Hz 380~415V-3Ph-50Hz 380~415V-3Ph-50Hz 380~415V-3Ph-50Hz kW 25.2 28 33.5 Btu/h 85,982 95,536 114,302 Input kW 5.8 7.1 8.8 EER W/W 4.29 3.97 3.81 kW 27 31.5 37.5 Btu/h 92,124 107,478 127,950 Input kW 6.1 7.6 9.0 COP W/W 4.39 4.17 4.17 Power supply Technical specifications Outdoor Unit Model Power supply Capacity Cooling (*1) Heating (*1) 1 1 1+1 DC Inverter DC Inverter DC Inverter Quantity Type Outdoor Fan Motor Quantity Type 1 1 2 DC Motor DC Motor DC Motor 13 16 20 Maximum quantity of connected indoor units Outdoor air flow m3/h 11242 11242 15620 Outdoor sound level (*2) dB(A) 57 57 59 mm 960*1615*765 960*1615*765 1250*1615*765 mm 1025*1790*830 1025*1790*830 1305*1790*820 kg 212 / 227 212 / 227 288 / 308 Gas Ø 25.4 Ø 25.4 Ø 31.8 Liquid Ø 12.7 Ø 12.7 Ø 15.9 Dimension(W*H*D) Outdoor unit Packing (W*H*D) Net/Gross weight Refrigerant Piping Lines (*3) 1.Nominal conditions Heating o o o o 27 C DB (80.6 F), 19 C WB (60 F) o o o o 20 C DB (68 F), 15 C WB (44.6 F) o o 35 C DB (95 F) o o 7 C DB (42.8 F) Pipe length Level difference 7.5m 0m 7.5m 0m 2.Sound level: Anechoic chamber conversion value, measured at a position 1m in front of the unit and 1.5m above the floor. 3.Refrigerant pipe dim.listed here only for when the total equivalent length <90m. For the data when total quivalent length 90 m please refer to technical manual. 31 kW 40 45 50 Btu/h 1,36,480 1,53,540 1,70,600 Input kW 11.3 13.2 14.8 EER W/W 3.54 3.40 3.38 kW 45 50 56 Btu/h 153,540 170,600 191,072 kW 11.2 12.8 14.4 W/W 4.02 3.91 3.89 1+1 1+1 1+1 DC Inverter DC Inverter DC Inverter 2 2 2 DC Motor DC Motor DC Motor 23 26 29 Quantity Outdoor Fan Motor Type Quantity Type Maximum quantity of connected indoor units Outdoor air flow m3/h 15620 15620 15770 Outdoor sound level (*2) dB(A) 61 62 62 mm 1250*1615*765 1250*1615*765 1250*1615*765 mm 1305*1790*820 1305*1790*820 1305*1790*820 kg 288/308 288/308 310/330 Gas Ø 31.8 Ø 31.8 Ø 31.8 Liquid Ø 15.9 Ø 15.9 Ø 19.1 Dimension(W*H*D) Outdoor unit Packing (W*H*D) Net/Gross weight Refrigerant Piping Lines (*3) 1.Nominal conditions Outdoor Indoor Cooling 380~415V-3Ph-50Hz COP Compressor 38VF018H119010 380~415V-3Ph-50Hz Heating (*1) Input Compressor 38VF016H119010 380~415V-3Ph-50Hz Capacity Capacity 38VF014H119010 18 HP V-Ph-Hz Capacity Cooling (*1) 14 HP - 16 HP Indoor Outdoor Pipe length Level difference Cooling 27oC DB (80.6oF), 19oC WB (60oF) 35oC DB (95oF) 7.5m 0m Heating 20oC DB (68oF), 15oC WB (44.6oF) 7oC DB (42.8oF) 7.5m 0m 2.Sound level: Anechoic chamber conversion value, measured at a position 1m in front of the unit and 1.5m above the floor. 3.Refrigerant pipe dim.listed here only for when the total equivalent length <90m. For the data when total quivalent length 90 m please refer to technical manual. 32 DIMENSIONAL DETAILS Outdoor Unit dimensions ( Unit : mm ) Mini VRF 12/14/16/18 HP 1615 1615 8/10 HP Traditional Air Conditioning System 765 765 960 765 765 1250 Refrigerant Piping Connections ( Unit : mm ) Liquid side A B Mini VRF Air Conditioning System Gauge point Cooling only type without Oil balancer For parallel connect the modular units F E D Gas side C R: Pipe Connection R Section View HP SIZE 8 10 12 14 16 18 A 199 199 169 169 169 169 B 159 159 209 209 209 209 C 195 195 169 169 169 169 D 168 168 168 168 168 168 E 208 208 208 208 208 208 F 220 220 Liquid pipe 2'ĭ 2'ĭ Gas pipe 33 2'ĭ 2'ĭ 220 220 220 220 2'ĭ 2'ĭ 2'ĭ 2'ĭ 2'ĭ 2'ĭ 2'ĭ 2'ĭ Carrier MINI VRF Inverter system is a highly efficient solution for small commercial buildings that requiring heating and cooling system up to 8 zones in one outdoor unit. Carrier offers more than 100 models in about 15 types indoor units can be combined with MINI VRF Inverter outdoor unit and Max indoor unit is 15, which provides individual comfort space, easy installation and control. This is a flexible system that bridges the capacity gap between VRF and Multi systems – ideal for commercial and private applications. 34 Mini VRF DC Inverter System Line - up Residential & Light Commercial Applications Indoor Unit (kW) 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 10.5 11.2 14.0 16.0 20.0 25.0 Luxury Apartments Villas Restaurants Offices 28.0 One-way Cassette Two-way Cassette Four-way Cassette Compact Four-way Cassette Low Static Pressure Ducted Medium Static Pressure Ducted High Static Pressure Ducted Floor / Celling High Wall Exposed Floor-standing Concealed Floor-standing Console 35 36 ( FLEXI__ )14 (1) (2) (3) Flexi Applications Flexi Design Flexi Selection Caters to varied applications Residential Light Commercial (4) • Modular & Individual outdoor units • Variety of indoor units. (5) Flexi Outdoor Units Lineup Flexi Outdoor Units Lineup 4HP to 16HP 2.2kW to 28kW (7) (8) SIDE DISCHARGE OUTDOOR UNITS – Mini VRF Selection software provides flexibility of model selection (6) Flexi Efficency High EER in cooling High COP in heating Technical Specifications Model Power Supply Cooling(*1) (9) Heating (*1) Flexi Comfort Flexi Reliability 38VR004H112010 Flexi Control System 38VR005H112010 38VR006H112010 V-Ph-Hz 220 ~ 240 - 1 - 50Hz 220 ~ 240 - 1 - 50Hz 220 ~ 240 - 1 - 50Hz Capacity kW 12 14 15.5 Input kW 3.95 4.85 5.65 EER W/W 3.04 2.89 2.74 Capacity kW 13.2 15.4 17 Input kW 3.55 4.35 5.5 3.72 3.54 3.09 1 1 1 DC Inverter DC Inverter DC Inverter 6 6 7 COP Qantity Compressor Type Maximum quality of connected Inoor Unit ( 10 ) Flexi Comfort Individual Control Central Control ( 13 ) ( 11 ) Flexi Safety Protections ( 14 ) ( 12 ) Flexi Installation Outdoor air flow m3/h 6000 6000 6000 Outdoor Sound Level (sound pressure level)(*2) dB(A) 58 57 57 Dimansion (W x H x D) mm 900x1327x320 900x1327x320 900x1327x320 Packing (W x H x D) mm 1030x1456x435 1030x1456x435 1030x1456x435 Net/Gross weight kg 95/106 95/106 100/111 Design pressure MPa 4.4/2.6 4.4/2.6 4.4/2.6 Refirgerant piping(*3) Liquid/Gas mm Ɏ9.52 / Ɏ15.9 Ɏ9.52 / Ɏ15.9 Ɏ9.52 / Ɏ15.9 Outdoor Unit 1.Nominal conditions Outdoor Indoor Flexi Sercive & Maintenance 37 Flexi Accessories o o o 35 C DB (95 F) o 7 C DB (42.8 F) 27 C DB (80.6 F), 19 C WB (60 F) Heating 20 C DB (68 F), 15 C WB (44.6 F) o o o Pipe length o Cooling o o Level difference o 7.5m 0m o 7.5m 0m 2.Sound level: Anechoic chamber conversion value, measured at a position 1m in front of the unit and 1.5m above the floor. 3.Refrigerant pipe dim.listed here only for when the total equivalent length <90m. For the data when total quivalent length 90 m please refer to technical manual. 38 Technical Specifications Technical Specifications Model 38VR004H119010 Power Supply Cooling(*1) V-Ph-Hz 380-415-3-50 380-415-3-50 380-415-3-50 Capacity kW 12 14 15.5 Input kW 3.9 4.75 5.6 3.08 2.95 2.77 EER Heating(*1) Capacity kW 13.2 15.4 17 Input kW 3.75 3.38 3.15 3.52 3.38 3.15 1 1 4 COP Compressor 38VR005H119010 38VR006H119010 Qantity Type DC Inverter DC Inverter DC Inverter 6 6 7 Maximum quality of connected Inoor Units Outdoor air flow m3/h 6983 6500 6000 Outdoor Sound Level (sound pressure level)(*2) dB(A) 57 57 57 Dimansion (W x H x D) mm 900x1327x320 900x1327x320 900x1327x320 Packing (W x H x D) mm 1030x1456x435 1030x1456x435 1030x1456x435 Net/Gross weight kg 95/106 95/106 102/113 Outdoor Unit Design pressure Refirgerant piping(*3) Liquid/Gas MPa 4.4/2.6 mm Ɏ9.53 / Ɏ15.9 Model 38VR007H11901S Power Supply Cooling(*1) 380-415-3-50 380-415-3-50 380-415-3-50 380-415-3-50 380-415-3-50 Capacity kW 17.5 22.4 26 40 45 Input kW 5.3 7.2 8.4 11.9 13.6 3.30 3.11 3.10 3.35 3.32 Capacity kW 19 24.5 28.5 45 50 Input kW 5 6.7 7.9 11.1 12.7 3.80 3.66 3.61 4.05 3.93 1 1 1 1+1 1+1 DC Inverter DC Inverter DC Inverter DC Inverter DC Inverter 9 11 12 14 15 COP Qantity Compressor Type Maximum quality of connected Inoor Unit Outdoor air flow m3/h 6800 10494 10494 16575 16575 Outdoor sound level (sound pressure level)(*2) dB(A) 59 59 60 62 62 Dimansion (W x H x D) mm 900 x 1327 x 320 1120 x 1558 x 400 1120 x 1558 x 400 1360 x 1650 x 540 1460 x 1650 x 540 Packing (W x H x D) mm 1030 x 1456 x 435 1270 x 1575 x 480 1270 x 1575 x 480 1450 x 1785 x 560 1550 x 1785 x 560 Net/Gross weight kg 107/118 146.5 / 162.5 147 / 163 240/260 275/290 mm Ɏ9.53 / Ɏ19.1 Ɏ9.52 / Ɏ19.1 Ɏ9.52 / Ɏ22.2 Ɏ12.7 / Ɏ22.2 Ɏ12.7 / Ɏ25.4 Outdoor Unit Refirgerant piping(*3) Liquid side/Gas side 1.Nominal conditions Outdoor Indoor 1.Nominal conditions Outdoor Indoor o o o 35 C DB (95 F) o 7 C DB (42.8 F) Cooling 27 C DB (80.6 F), 19 C WB (60 F) Heating 20 C DB (68 F), 15 C WB (44.6 F) o o o Pipe length o o o 38VR014H11901S 38VR016H11901S V-Ph-Hz EER Heating(*1) 38VR008H11901S 38VR010H11901S Level difference o 7.5m 0m o 7.5m 0m o o o 35 C DB (95 F) o 7 C DB (42.8 F) 27 C DB (80.6 F), 19 C WB (60 F) Heating 20 C DB (68 F), 15 C WB (44.6 F) o o o Pipe length o Cooling o o Level difference o 7.5m 0m o 7.5m 0m 2.Sound level: Anechoic chamber conversion value, measured at a position 1m in front of the unit and 1.5m above the floor. 3.Refrigerant pipe dim.listed here only for when the total equivalent length <90m. For the data when total quivalent length 90 m please refer to technical manual. 2.Sound level: Anechoic chamber conversion value, measured at a position 1m in front of the unit and 1.5m above the floor. 3.Refrigerant pipe dim.listed here only for when the total equivalent length <90m. For the data when total quivalent length 90 m please refer to technical manual. 39 40 Mini VRF DC Inverter Outdoor Unit Capacity Maximum Quantity of Indoor Units 12 KW 6 14 KW 6 15.5 KW 7 17.5 KW 9 22.4 KW 11 26 KW 12 40 KW 14 45 KW 15 Wide Stable Operation Range COOLING MODE Outdoor Temperature -15°C Using Branch Joints for refrigerant piping connections between outdoor unit and indoor units Outdoor Units 12 KW 14 KW 15.5 KW 17.5 KW 22.4 KW 26 KW 40 KW 45 KW HEATING MODE 27°C Example -20 -10 0 10 20 30 40 50 60 Outdoor temp. °C ( D.B ) Branch Joint Space Saving Design MINI VRF units are slimmer and more compact, resulting in significant savings in installation space. In some large residential spaces or some light commercial space, such as villa, restaurant, usually it need more than one indoor unit, so outside the building are also full of outdoor units. Now Carrier can provide an effective solution-Carrier MINI VRF DC Inverter system. Since now the beauty of the building will be back. Indoor Units Example Branch Box Indoor Units 41 Outdoor Temperature -15°C Using Branch box for refrigerant piping connections between outdoor unit and indoor units Outdoor Units 12 KW 14 KW 15.5 KW 17.5 KW 22.4 KW 26 KW 40 KW 45 KW 48°C Traditional Air Conditioning MINI VRF 42 Long Piping Length Mini VRF provides 100 m Actual Total Piping Length. - The height difference between outdoor unit and indoor units can be up to a maximum of ( ODU Up 20m or ODU Down 30m ). - The height difference between indoors unit can be up to a maximum of 8m. - These generous allowances facilitate an extensive variety of system designs. 120 m Longest equivalent piping length New designed fan guard Air deflector New designed fan High Efficiency DC Fan Motor 40 m The first branch joint to the farthest indoor unit 15 m The IDU to the nearest branch pipe Actual Length 12 - 14 - 15.5 kW 100 m 60 m 22.4 - 26 kW 120 m 60 m 40 - 45 kW 250 m 100 m Equivalent Length 70 m 70 m 120 m 20 m 20 m 40 m 30 m 30 m 30 m 20 m 20 m 20 m 8m 8m 8m Actual Total Piping Length(*1) Longest Piping Equivalent Piping Length ( The farthest IDU to the first Indoor unit branch ) Level Difference High Efficiency Fan Housing & Outlet Grille High Efficiency Outdoor Fan (s) Permitted value ( m ) Piping Length High Efficiency MINI VRF DC Inverter Outdoor Unit Newly Designed Fan Guard 8 m Level difference between IDUs Level difference between IDU and ODU ODU Up20 m ODU Down30 m - Outdoor Unit Level Difference Up Between Outdoor Unit IDU~ODU Down Level Difference Between IDU~IDU High Efficiency Outdoor Coil High Efficiency DC Inverter Twin Rotary Compressor *1 Total pipe length is equal to all liquid pipe or all the gas pipe length. 43 44 High Efficiency DC Inverter Rotary Compressor Technology Highly Efficient DC Motor: - Creative motor core design. - High density neodymium magnet. - Concentrated type stator. - Wider operating frequency range. Compact Design for Effective Use of Space Compact size and light weight design minimizes the installation footprint, reduces the installation floor load, and is easier for transportation. For some projects Better balance and Extremely Low Vibration: - Twin eccentric cams. - 2 balance weights. the units can even be transported through the elevator or forklift, reduce access problem at the jobsite and reduce time and labor. More convenience in installation Highly Stable Moving Parts: - Optimal material matching rollers and vanes - Optimize compressor drive technology. - Highly robust bearings. - Compact structure. Compressor ( Twin Rotary ) structure A four-direction space is available for connecting pipes and wiring in various installation sites. For installation in different types of rooms in small offices and shops,the Mini VRF system offers a wide range of indoor and outdoor units. These are almost as easy to install as residential air conditioning systems, making them the ideal choice. Front side Right side Back side Back Side Bottom side Powerful magnets provide high torque and efficiency and achieve 70% reduction in volume. Big pipe Right Side Front side New DC motor-centralized winding Bottom Side Common DC motor-distributing winding Simple Signal Line Connection Centralizing winding Distributing winding 45 Efficiency-Rotor Speed Curve Compressor efficiency Installation is easier as communication wiring can be shared by indoor & outdoor units. It’s easy for the user to retrofit the existing system with a centralized control by simply connecting to the outdoor units. PQE & XYE : only one set of PQE signal wires can achieve communication among indoor units, outdoor units and the network. P Q E X Y E 20 40 60 80 Reversible communication, central controller can be connected from indoor side or outdoor side as you wish. X Y E 100 Rotor speed(s-1) P Q E P Q E P Q E P Q E Wireless controller can query and modify each indoor unit’s address. 46 Dimensions of MINI VRF DC Inverter - Outdoor Units Flexi Indoor Units Dimensions ( mm ) C D E F Size B A B C D E G F G 12kW to 15.5 kW 900 1327 600 348 320 360 400 17.5 kW to 26 kW 1120 1558 668 414 400 494 528 40 kW 505 1650 1010 475 450 500 540 45 kW 505 1650 1060 475 450 500 540 Indoor Units Lineup Cassette One-way 40VZ Series Cassette Two-way 40VT Series A Cassette Compact Four-way 40VX Series R: Pipe Connection Cassette Four-way 40VK Series Fat Pipe Low Static Pressure Ducted 42VD - H112002011 Series Medium Static Pressure Ducted 42VD - H112013011 Series Medium Static Pressure Ducted 42VD - H112003010 Series High Static Pressure Ducted 42VD - H112011010 Series Front Out Pipe Side Out Pipe Back Out Pipe Under Surface Out Pipe High Wall S Type 42VH - 112000101 Series High Wall R Type 42VH - 112000102 Series Floor / Under - Ceiling 42VF Series Console 42VC Series Floor Standing 42VS Series Fresh Air-processing Unit 42VD - H112211010 Series AHU Kit 47 48 INDOOR UNITS LINEUP VRF CASSETTE INDOOR UNITS Model Type 18 22 28 36 45 56 71 80 90 100 112 125 140 160 200 250 280 400 450 560 (capacity *100w) One-way cassette ※ VRF Cassette indoor unit is the optimum air conditioning solution for applications which require ceiling installation above false ceiling, elegant appearance and ultimate comfort combined with efficient and quiet operation, optimum air distribution and efficient Indoor Air Quality (IAQ) and environmentally friendly HFC refrigerant R410A. ŸŸ Ÿ Ÿ Ÿ Ÿ Ÿ Water pump is standard standard. Two-way cassette ※ ŸŸŸŸ ŸŸ Water pump is standard. Compact fourway cassette ※ ŸŸŸŸ Water pump is standard. ※ Four-way cassette Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ Ÿ ŸŸ Ÿ Water pump is standard. Low Static Pressure Ducted ŸŸŸŸŸ Ÿ Ÿ ͤ Medium Static Pressure Ducted ŸŸŸŸŸŸ Water pump is standard. ※ VRF Cassette One-way ŸŸŸŸŸ Ÿ VRF Cassette Two-way (V V type) Water pump is standard ŸŸŸ Ÿ ŸŸ High Static Pressure Ducted ŸŸŸ Ÿ* Ÿ* Ÿ* *customized model. High Wall S Type Ÿ ŸŸŸŸ High Wall R Type Floor & Ceiling Console 40VZ-H11200011 Model ŸŸŸŸŸŸ Ÿ Ÿ 40VT-H10200010 028 Model 006 009 012 018 024 028 1.8 kW 2.2 kW 2.8 kW 3.6 kW 4.5 kW 5.6 kW 7.1 kW 2.2 kW 2.8 kW 3.6 kW 4.5 kW 5.6 kW 7.1 kW 2.2 kW 2.6 kW 3.2 kW 4.0 kW 5.0 kW 6.3 kW 8.0 kW Cooling Capacity Heating Capacity 2.6 kW 3.2 kW 4.0 kW 5.0 kW 6.3 kW 8.0 kW 005 Cooling Capacity Heating Capacity ŸŸŸ 2.2 ~ 7.1 kW Cooling 2.6 ~ 8.0 kW Heating 1.8 ~ 7.1 kW Cooling 2.2 ~ 8.0 kW Heating 006 009 012 018 024 VRF Cassette Compact Four-way VRF Cassette Four-way Ÿ ŸŸŸ Ÿ ŸŸŸŸŸŸ Floor standing Ÿ ŸŸŸŸŸŸ 2.8 ~ 14 kW Cooling 3.2 ~ 15 kW Heating Ÿ Ÿ ŸŸŸ AHU Kit ※ water pump is standard 49 Ÿ 40VK-H11200011 2.2 ~ 4.5 kW Cooling 2.4 ~ 5.0 kW Heating Fresh Air processing unit Ÿ Model 006 009 012 018 Cooling Capacity Heating Capacity 2.2 kW 2.8 kW 3.6 kW 4.5 kW Model 40VX-H11200010 Ÿ Model Cooling Capacity Heating Capacity 2.4 kW 3.2 kW 4.0 kW 5.0 kW Cooling Capacity Heating Capacity 009 012 018 024 028 2.8 kW 3.6 kW 4.5 kW 5.6 kW 7.1 kW 3.2 kW 4.0 kW 5.0 kW 6.3 kW 8.0 kW 032 036 040 048 056 8.0 kW 9.0 kW 10.0 kW 11.2 kW 14.0 kW 9.0 kW 10.0 kW 11.0 kW 12.5 kW 15.0 kW 50 VRF Cassette - One Way 40VZ Series Auto Restart Fresh Air Part names Auto Addressing Cleanable Panel Small one-way cassette type 1.8 ~ 7.1 kW Cooling 2.2 ~ 8.0 kW Heating LED Wireless Controller Anti-Cold Air Function LED Display Built-in Drain Pump Wired Controller Super High Air Flow Grounding Screw (In the control box) One-way cassette type Air Out, Air Out Louver (Adjust the air-Aout direction) Air Out Horizontal Louver (Adjust air-out direction) DISPLAY Grounding Screw (In the control box) Follow Me Air Intake (Intake air here) Air Filter (Filter the dust in the intake air) (In the air intake) Air Intake (Intake air here) Air Filter (Filter the dust in the intake air) (In the air intake) Smart controls Height 189 mm only Compact design, ultra slim body with a min. height of 153mm only or 189mm only, especially suitable for narrow ceiling places, such as lobby, small-size meeting room, etc. Standard wireless remote control WL-12-CM 189mm (sizes 18-28) 153mm (sizes 5-12) Auto swing mechanism guarantees even distribution of airflow and better balance of room temperature. UItra Thin Standard built-in drain pump one direction airflow design suits corner installation. Standard built-in drain pump with 750mm pumphead and slim body makes the installation free from limitation of story height. Optional wired control WR-12-CM Smart wireless remote controller or optional wired controller with smart, complete control and safety function built in the control systems. Smart supply airflow Auto-swing Press SWING button, the louver will swing up and down. When cooling When heating Adjust the louver horizontally. Adjust the louver down(vertically). 750mm Maximum air circulation area Fresh air, improved air quality Reserved fresh air intake port for high quality air supply requirement, create a comfort and healthy environment. Special enzyme sterilization and filtering technology can filter the bacteria, smog, pollen, etc. Provide plenty clean, healthy and natural air supply. Easy service & maintenance Easy removal of air filters for cleaning Air filter Acetaldehyde Acetic acid 51 Formol NH3 Easy access to indoor unit components Remote on / off function and alarm function 52 40VZ Series 40VZ Series Technical Specifications 40VZ00A02 Panel Power supply Heating Capacity Indoor air flow (H/M/L) Indoor sound level (Hi/Mid/Lo) Panel Kw 1.8 2.2 2.8 3.6 6140 7500 9550 12280 Kw 2.2 2.6 3.2 4 Btu/h 7500 8870 10920 cfm dB(A) 308/238/162 37/34/30 39/37/34 1054 x 153 x 425 Packing (WxHxD) mm 1155 x 245 x 490 Net/Gross weight kg 12.5 / 16 mm 1180 / 36.5 / 465 Packing (WxHxD) mm 1232 / 107 / 517 Net/Gross weight kg 3.5 / 5.2 R410A Operation temperature 40/38/34 40VZ00A03 V-Ph-Hz Indoor sound level (Hi/Mid/Lo) Indoor unit Panel mm ĭ6.35/ĭ12.7 Refrigerant piping mm Ɏ25 220~240-1-50 Kw 4.5 5.6 7.1 Btu/h 15400 19100 24200 Kw 5 6.3 8 Btu/h 17100 21500 27300 cfm 408/353/280 466/405/323 549/441/349 dB(A) 41/39/35 42/40/36 44/41/37 Dimension (WxHxD) mm 1204 x 189 x 443 Packing (WxHxD) mm 1370 x 295 x 505 Net/Gross weight kg 18.5/23.2 18.8/23.5 Dimension (WxHxD) mm 1350 x 25 x 505 Packing (WxHxD) mm 1410 x 95 x 560 Net/Gross weight kg 4/5.4 19.5/24.2 R410A Refrigerant type Refrigerant control 18~30 40VZ028H11200011 40VZ00A03 Indoor air flow (H/M/L) EXV (built-in) C 40VZ024H11200011 40VZ00A03 Heating Capacity Type o 40VZ018H11200011 Panel Cooling Capacity 13 / 16.5 Dimension (WxHxD) Drainage water pipe diameter 13650 337/268/185 38/34/30 Model Power supply mm Liquid side/Gas side 40VZ00A02 220~240-1-50 Dimension (WxHxD) Refrigerant control 53 40VZ00A02 Btu/h Refrigerant type Refrigerant piping 40VZ00A02 V-Ph-Hz Cooling Capacity Indoor unit Technical Specifications 40VZ005H11200011 40VZ006H11200011 40VZ009H11200011 40VZ012H11200011 Model Type Liquid side/Gas side Drainage water pipe diameter Operation temperature mm mm o C EXV (built-in) ĭĭĭĭ ĭ25 18~30 54 VRF Cassette - Two Way 40VT Series Part names 2.2 ~ 7.1 kW Cooling 2.6 ~ 8.0 kW Heating Air Intake (Intake room air here) LED Auto Restart Fresh Air Auto Addressing Cleanable Panel LED Display Anti-Cold Air Function DISPLAY Inhalation grating Built-in Drain Pump Wireless Controller Wired Controller Follow Me Super High Air Flow Super quiet operation High airflow Optimized airflow duct with low resistance makes noise level get reduced greatly, min. 24 dB(A). High airflow for high ceiling application guarantees equal comfort of large space. It makes every comer of the room get even distribution of airflow and temperature. Stylish design and slim body Thanks to the stylish appearance and slim boy, the unit can be harmonious with the room decoration and ambient. Slim body with only 300 mm height needs small suspended ceiling space. Installation is free of story height limitation which makes the decoration much more flexible. Electric control box Air Out Louver Air Filter (Filter the dust in the intake air) (Adjustable) Smart controls Standard wireless remote control WL-12-CM Smart wireless remote controller or optional wired controller with smart, complete control and safety function built in the control systems. Smart supply airflow Auto-swing Press SWING button, the louver will swing up and down. 300mm Optional wired control WR-12-CM When cooling When heating Adjust the louver horizontally. Adjust the louver down(vertically). 305mm Standard built-in drain pump Easy service & maintenance Standard built-in drain pump with 750mm pumphead (higher pumphead can be customized). Easy removal of air filters for cleaning Air Intake (Intake room air here) 750mm Inhalation grating Air Filter (Filter the dust in the intake air) Flat-type suction grille design makes maintenance work very easy. 55 Air Out Louver (Adjustable) Easy access to indoor unit components Remote on / off function and alarm function 56 40VT Series 40VT Series Technical Specifications Model Power supply 40VT009H10200010 40VT012H10200010 220-240V-1Ph-50Hz 2.2 2.8 3.6 Btu/h 7,500 9,500 12,200 Input power W 65 65 65 Rated current A 0.35 0.45 0.45 kW 2.6 3.2 4 Capacity Btu/h 8,900 10,900 13,600 Input power W 65 65 65 Rated current A 0.35 0.45 0.45 cfm 385/312/241 385/312/241 427/348/270 dB(A) 33/29/24 36/32/29 36/32/29 Indoor air flow (H/M/L) Indoor sound level (Hi/Mid/Lo) Dimension (WxHxD) Packing (WxHxD) Net/Groos weight mm mm kg 1172x300x592 1355x400x675 33/42 1172x300x592 1355x400x675 33/42 Model Power supply kW Cooling Indoor unit 40VT006H10200010 V-Ph-Hz Capacity Heating Technical Specifications 1172x300x592 5.6 7.1 Btu/h 15,300 19,100 24,200 Input power W 97 112 153 Rated current A 0.55 0.55 0.75 kW 5 6.3 8 Btu/h 17,000 21,500 27,300 Input power W 97 112 153 Rated current A 0.55 0.55 0.75 cfm 500/394/324 577/471/394 706/589/4531 dB(A) 39/35/30 39/35/30 44/40/34 Dimension (WxHxD) mm 1172x300x592 1172x300x592 1172x300x592 Packing (WxHxD) mm 1355x400x675 1355x400x675 1355x400x675 Net/Gross weight kg 35/44 35/44 35/44 CE-MBQ2-01 (MBQ2-01) CE-MBQ2-01 (MBQ2-01) 1430x90x680 1430x90x680 1430x90x680 1525x130x765 1525x130x765 1525x130x765 10.5/15 10.5/15 10.5/15 R410A R410A R410A Capacity Heating Indoor air flow (H/M/L) Indoor sound level (Hi/Mid/Lo) Indoor unit Model Model Panel CE-MBQ2-01 (MBQ2-01) CE-MBQ2-01 (MBQ2-01) CE-MBQ2-01 (MBQ2-01) Dimension (WxHxD) mm 1430x90x680 1430x90x680 1430x90x680 Packing (WxHxD) mm 1525x130x765 1525x130x765 1525x130x765 Net/Groos weight kg 10.5/15 10.5/15 10.5x15 R410A R410A R410A Refrigerant type Refrigerant control Type Refrigerant piping Liquid side/Gas side mm Ɏ6.35/Ɏ Nb×mm2 3×0.75 mm IDɎ25 / ODɎ Connecting wiring Signal wiring Drainage water pipe diameter Electronic expansive valve Dimension (WxHxD) mm Packing (WxHxD) mm Net/Gross weight kg Panel Refrigerant type Refrigerant control Type Refrigerant piping Liquid side/Gas side mm Connecting wiring Signal wiring Drainage water pipe diameter ɎɎ ɎɎ Nb×mm2 3×0.75 mm ID Ɏ2'Ɏ Wireless remote controller Standard Controller Wireless remote controlle Optional controller Wired controller WR-12-CM Optional controller Wired controller WR-12-CM 57 o C Cooling : 18 ~ 30 Heating : 10 ~ 28 Operation temperature o C CE-MBQ2-01 (MBQ2-01) Electronic expansive valve Standard Controller Operation temperature 40VT028H10200010 4.5 Cooling 33/42 40VT024H10200010 220-240V-1Ph-50Hz kW Capacity 1355x400x675 40VT018H10200010 V-Ph-Hz ɎɎ Cooling : 18 ~ 30 Heating : 10 ~ 28 58 VRF Cassette Compact - Four Way 40VX Series Part names 2.2 ~ 4.5 kW Cooling 2.4 ~ 5.0 kW Heating Air Out Louver (Adjustable) Two-direction or Three-direction Air Outlet For the detailed information please consult your local dealer. Auto Restart Fresh Air Auto Addressing Cleanable Panel Built-in Drain Pump Anti-Cold Air Function Wireless Controller LED Grounding Screw (In the control box) Air Intake (Intake air from here) Lock buckle (For closing the Air Grille) LED Display Air Filter (Filter the dust in the intake air) DISPLAY Wired Controller Follow Me Super High Air Flow Smart controls Compact ompact design, easy installation, service and maintenance Extremely compact casing (575mm in width and 260mm in depth) makes it perfectly match with the ambient decoration. Little space is required for installation into a shallow ceiling. Due to its compact body and light weight, all models can be installed without a hoist. Quiet operation, soft air supply Uniform air flow of four ways Standard wireless remote control WL-12-CM Optional wired control WR-12-CM Smart wireless remote controller or optional wired controller with smart, complete control and safety function built in the control systems. Smart supply airflow Diffuser Cooling operation Heating operation Adjust the louver horizontally. Adjust the louver down. 3-D spiral fan blade Streamline plate ensures quietness Advanced 3-D spiral fan design reduces the air resistance and operation noise. 360°Airflow outlet 360°air outlet provides strong circulating air flow to cool or heat every corner of the room and realizes even temperature distribution 59 The four air discharge port provides strong circulating air flow to cool or heat every corner of the room and realizes even temperature distribution; by choosing high airflow mode, high ceiling application over 3m can get equal comfort. Easy service & maintenance Easy removal of air filters for cleaning Standard built-in drain pump 500mm Drain up pump with 500mm pumphead fitted as standard, max. up to 600mm head. Easy access to indoor unit components Remote on / off function and alarm function 60 40VX Series 40VX Series Technical Specifications Technical Specifications Model Power supply 40VX006H11200010 220~240-1Ph-50Hz V-ph-Hz Capacity kW Power supply 2.2 7,500 9,500 Input power W 50 50 Rated current A 0.175 0.175 kW 2.4 3.2 Btu/h 8,900 10,900 Input power W 42 42 Rated current A 0.175 0.175 cfm 308/244/185 308/244/185 dB(A) 35.8/33.4/23.4 35.8/33.4/23.4 Dimension(W x H x D) mm 630x260x570 630x260x570 Indoor unit Packing(W x H x D) mm 675x285x575 675x285x575 kg 16/20 16/20 Dimension(W x H x D) mm 647x50x647 647x50x647 Packing(W x H x D) mm 715x123x715 715x123x715 kg 2.5 / 4.5 2.5 / 4.5 R410A R410A 6.35/12.7 6.35/12.7 Net/Gross weight Panel Net/Gross weight Refrigerant Type Refrigerant piping Liquid side/Gas side mm Connection wiring Signal wiring mm2 3*0.5 (3-core shielded wire) Drainage water pipe diameter mm ID Ɏ2'Ɏ 3.6 4.5 Btu/h 12,200 15,300 Input power W 58 58 Rated current A 0.21 0.21 kW 4 5 Btu/h 13,600 17,000 Input power W 50 50 Rated current A 0.21 0.21 cfm 360 / 307 / 241 360 / 307 / 241 dB(A) 41.5 / 35.6 / 28.8 41.5 / 35.6 / 28.8 Dimension (WxHxD) mm 630x260x570 630x260x570 Packing (WxHxD) mm 675 x 285 x 675 675 x 285 x 675 Net/Gross weight kg 18 / 22 18 / 22 Dimension (WxHxD) mm 647 x 50 x 647 647 x 50 x 647 Packing (WxHxD) mm 715 x 123 x 715 715 x 123 x 715 Net/Gross weight kg 2.5 / 4.5 2.5 / 4.5 R410A R410A 6.35/12.7 6.35/12.7 Cooling Capacity Heating Indoor air flow (Hi/Mi/Lo) Sound level (H/M/L) Indoor unit Panel Refrigerant Type Refrigerant piping Liquid side/Gas side mm Connection wiring Signal wiring mm2 3*0.75 (3-core shielded wire) Drainage water pipe diameter mm IDɎ2'Ɏ Standard Controller Wireless remote controller Standard Controller Wireless remote controller Optional controller Wired controller WR-12-CM Optional controller Wired controller WR-12-CM Operation temperature 61 220~240-1Ph-50Hz kW Heating Sound level (H/M/L) 40VX018H11200010 Capacity Capacity Indoor air flow (Hi/Mi/Lo) 40VX012H11200010 V-ph-Hz 2.82 Btu/h Cooling Model 40VX009H11200010 o C Cooling: 18~30 Heating: 10~28 Operation temperature o C Cooling:18~30 Heating:10~28 62 VRF Cassette - Four Way 40VK Series Part names Air Out Louver (Adjustable) Two-direction or Three-direction Air Outlet For the detailed information please consult your local dealer. 2.8 ~ 14 kW Cooling 3.2 ~ 15 kW Heating LED Auto Restart Fresh Air Auto Addressing Cleanable Panel Built-in Drain Pump Anti-Cold Air Function LED Display Wireless Controller Wired Controller Super High Air Flow Grounding Screw (In the control box) Air Intake (Intake air from here) DISPLAY Lock buckle (For closing the Air Grille) Air Filter (Filter the dust in the intake air) Follow Me Uniform air flow of four ways The four air discharge port provides strong circulating air flow to cool or heat every corner of the room and realizes even temperature distribution; by choosing high airflow mode, high ceiling application over 3m can get equal comfort. Four-way Airflow(4-stage fan speed) Panel available Smart controls (White) Standard Ŷ Streamline plate ensures quietness Ŷ Advanced 3-D spiral fan design reduces the air resistance and operation noise. Diffuser 3-D spiral fan blade Smart self diagnostic function By adding digital tube displayer on the display board, the Error Codes can be displayed directly on it which helps to find and shoot the trouble. Reserved multi-function ports Standard built-in drain pump can take up the condenser water to 750mm which helps to make easier installation of the drain piping system. 750mm upmost Optional wired control WR-12-CM Smart wireless remote controller or optional wired controller with smart, complete control and safety function built in the control systems. Smart supply airflow Cooling operation Heating operation Adjust the louver horizontally. Adjust the louver down. To another room Fresh Air Intake Standard built-in drain pump Standard wireless remote control WL-12-CM Quiet operation, soft air supply For duct connecting Slim compact design Easy service & maintenance Easy removal of air filters for cleaning Slim ultra-thin Slim compact design for easy installation, service and maintenance. Height is only 230mm for sizes 012-018-024-028-032 Height is only 300mm for sizes 036-040-048-056 230mm Easy access to indoor unit components Remote on / off function and alarm function 63 64 40VK Series 40VK Series Technical Specifications Technical Specifications Model Power Supply Cooling V-Ph-Hz 40VK024H11200011 Power Supply 220~240V-1Ph-50Hz kW 2.8 3.6 4.5 5.6 7.1 Btu/h 9500 12200 15300 19100 24200 W 80 80 80 80 80 kW 3.2 4 5 6.3 8 Btu/h 10900 13600 17000 21500 27300 W 80 80 80 80 80 Indoor air flow (H/M/L) CFM 450/376/326 450/376/326 533/436/383 533/436/383 560/452/391 Sound pressure level (H/M/L) dB(A) 32/31/30 32/31/30 36/35/34 36/35/34 39/37/36 Indoor unit body Net dimension (WxHxD) mm 840x230x840 Packing size (WxHxD) mm 955x260x955 Net/Gross weight kg 21.5/26.7 Net dimensio (WxHxD) 11.2 14 Btu/h 27300 30700 34100 38200 47800 W 100 130 150 150 160 kW 9 10 11.1 12.5 16 Btu/h 30700 34100 37500 42600 51200 W 100 130 150 150 160 Indoor air flow (H/M/L) CFM 707/601/465 785/665/535 972/768/664 972/768/664 977/786/664 Sound pressure level (H/M/L) dB(A) 43/40/38 43/40/38 46/42/40 46/42/40 46/42/40 Net dimension (WxHxD) mm 840x230x840 840x300x840 Packing size (WxHxD) mm 955x260x955 955x330x955 Net/Gross weight kg 23.7/28.9 28.7/34.1 Capacity Power Input Capacity Power Input Model 950x54x 950 Packing size (WxHxD) mm 1035x90x1035 Net/Gross weight kg 6/9 T-MBQ4-02B1 Net dimensio (WxHxD) mm 950x54x 950 Packing size (WxHxD) mm 1035x90x1035 Net/Gross weight kg 6/9 Refrigerant R410A Refrigerant Control Type Liquid pipe mm ĭ6.35 ĭ9.53 Gas pipe mm ĭ12.7 ĭ15.9 Single Wiring NbXmm2 3 x 0.75 3 x 0.75 3 x 0.75 R410A Refrigerant Control Electronic Expansion valve 3 x 0.75 Type Electronic Expansion valve Liquid pipe mm ĭ9.53 Gas pipe mm ĭ15.9 Refrigerant Pipe Refrigerant Pipe 3 x 0.75 Connecting Wiring Single Wiring NbXmm2 3 x 0.75 3 x 0.75 3 x 0.75 Drain pipe diameter IDĭ2'ĭ Drain pipe diameter IDĭ2'ĭ Standard Controller Wireless remote controller (WL-12-CM) Standard Controller Wireless remote controller (WL-12-CM) Wired remote controller Optional Controller Optional Controller 30.9/36.3 Indoor unit panel Refrigerant 65 220~240V-1Ph-50Hz 10 Indoor unit body Indoor unit panel Connecting Wiring 40VK056H11200011 9 T-MBQ4-02B1 mm V-Ph-Hz 40VK048H11200011 8 23.7/28.9 Model 40VK032H11200011 40VK036H11200011 40VK040H11200011 kW Cooling Heating Capacity Power Input Model 40VK028H11200011 Capacity Power Input Heating 40VK009H11200011 40VK012H11200011 40VK018H11200011 MPa MPa 3 x 0.75 3 x 0.75 Wired remote controller 66 VRF Ducted Low Static Pressure 42VD-H112002011 Series VRF DUCTED INDOOR UNITS VRF Ducted indoor unit is the optimum air conditioning solution for places which require ceiling installation above false ceiling and also require medium static pressure, optimum air distribution, increased air throw distance, minimum sound levels and environmentally friendly HFC refrigerant R410A. 1.8 ~ 7.1 kW Cooling 2.2 ~ 8.0 kW Heating Auto Restart Anti-Cold Air Function Auto Addressing Cleanable Panel Connectable To Duct Wireless Controller Wired Controller Follow Me VRF Ducted Medium Static Pressure VRF Ducted Low Static Pressure Super High Air Flow 1.8 ~ 7.1 kW Cooling 2.2 ~ 8.0 kW Heating 1.8 ~ 7.1 kW Cooling 2.2 ~ 8.0 kW Heating 42VD-H112002011 005 Cooling Capacity Heating Capacity 006 009 1.8 kW 2.2 kW 2.8 kW 012 018 024 028 3.6 kW 4.5 kW 5.6 kW 7.1 kW 2.2 kW 2.6 kW 3.2 kW 4.0 kW 5.0 kW 6.3 kW 8.0 kW VRF Ducted High Static Pressure 7.1 ~ 11.2 kW Cooling 8.0 ~ 12.5 kW Heating 8 ~ 14.0 kW Cooling 9 ~ 15.5 kW Heating 42VD-H112013011 Model Model Wide capacity range 14.0 ~ 16.0 kW Cooling 16.0 ~ 18.0 kW Heating Cooling Capacity Heating Capacity From 1.8KW to 7.1KW, seven models. 006 009 012 018 024 028 2.2 kW 2.8 kW 3.6 kW 4.5 kW 5.6 kW 7.1 kW 2.4 kW 3.2 kW 4.0 kW 5.0 kW 6.3 kW 8.0 kW Model Cooling Capacity Heating Capacity 8.0 kW 9.0 kW Thanks to the multiple-blade fan rotor and the air guide design, the airflow is getting smoother and more comfortable Low sound level Utilize the cross blow fan, the lowest sound level is 24dB (A). 42VD-H112003010 032 036 048 054 9.0 kW 11.2 kW 14.0 kW 10.0 kW 12.5 kW 15.5 kW More Smooth airflow with less turbulence Excellent choice for hotels and other sound sensitive places. Convenient installation The EXV is fixed beside of the indoor unit Suction chamber is included as stand.ard equipment VRF Ducted High Static Pressure Slim, light weight, and compact design Optional drain pump Min.5mm 42VD-H112011010 Model Cooling Capacity Heating Capacity Model Cooling Capacity Heating Capacity 67 20.0 ~ 28.0 kW Cooling 22.5 ~ 31.5 kW Heating 028 032 036 048 7.1 kW 8.0 kW 9.0 kW 11.2 kW 8.0 kW 9.0 kW 10.0 kW 12.5 kW 40 ~ 56 kW Cooling 45 ~ 53 kW Heating Drop-Ceiling 42VD-H112011010 054 055 056 058 750mm upmost 210mm 060 14.0 kW 16.0 kW 20.0 kW 25.0 kW 28.0 kW 16.0 kW 18.0 kW 22.5 kW 26.0 kW 31.5 kW Model Cooling Capacity Heating Capacity 140 160 190 40 kW 45 kW 56 kW 45 kW 50 kW 53 kW Uniform 210mm in height, compact design for easy installation where space over ceiling is limited, The whole body adopts fireproof plastic material, the minimum weight is 14kg ceiling Optional drain–up pump (750 mm pumphead). 68 Part names 42VD H112002011 Series Air Outlet (Connect the duct) Technical Specifications Control Box Air Intake (Intake room air here) Grounding Screw (In the control box) Model 42VD005H112002011 Power Supply Air Filter (Filter the dust in the air) V-Hz-Ph 1.8 2.2 2.8 Btu/h 6100 7500 9500 W 65 65 65 kW 2.2 2.6 3.2 Btu/h 7500 8870 10900 W 67 67 67 Indoor air flow (H/M/L) cfm 356/301/240 356/301/240 356/301/240 Indoor external static pressure Std (Min-Max) Pa 10(10~30) 10(10~30) 10(10~30) dB(A) 35/27/24 35/27/24 35/27/24 Dimension (W*H*D) mm 740*210*470 740*210*470 740*210*470 Packing (W*H*D) mm 910*230*510 910*230*510 910*230*510 Net/Gross weight kg 14/17.5 14/17.5 14/17.5 R410A R410A R410A Type EXV EXV EXV Heating Capacity Input Optional wired control WR-12-CM Indoor noise level (H/M/L) Smart wireless remote controller or optional wired controller with smart, complete control and safety function built in the control systems. Indoor Unit Smart supply airflow Refrigerant type Cooling operation Heating operation Adjust the louver horizontally. Adjust the louver down(vertically). The louver is horizontal Adjust left and right. Refrigerant Control vertical louver Refrigerant piping Liquid side/Gas side mm ĭ6.35/ĭ ĭĭ ĭĭ Connecting wiring Single wiring mm2 3*0.75 3*0.75 3*0.75 2'ĭ 2'ĭ 2'ĭ 'UDLQDJHZDWHUSLSHGLDPHWHU Easy service & maintenance 220-240V-50Hz-1Ph Capacity Input Standard wireless remote control WL-12-CM 42VD009H112002011 kW Cooling Smart controls 42VD006H112002011 Wireless is standard (Wired controller is optional) Wireless is standard (Wired controller is optional) Easy removal of air filters for cleaning Easy access to indoor unit components Remote on / off function and alarm function 69 70 VRF Ducted Medium Static Pressure 42VD H112013011 Series 2.2 ~ 14.0 kW Cooling 2.6 ~ 15.5 kW Heating 42VD H112002011 Series Auto Restart Fresh Air Built-in Drain Pump Anti-Cold Air Function Auto Addressing Cleanable Panel Connectable To Duct Super High Air Flow Follow Me Wired Controller Technical Specifications Compact size Model 42VD012H112002011 42VD018H112002011 42VD024H112002011 42VD028H112002011 Min.5mm Power Supply V-Hz-Ph Cooling 220-240V-50Hz-1Ph kW 3.6 4.5 5.6 7.1 Btu/h 12200 15300 19100 24200 W 67 85 85 108 kW 4.0 5.0 6.3 8.0 Btu/h 13600 17000 21500 27300 W 70 86 86 110 Indoor air flow (H/M/L) cfm 380/324/260 472/406/358 472/406/358 710/570/477 Indoor external static pressure Std (Min-Max) Pa 10(10~30) 10(10~30) 10(10~30) 10(10~30) dB(A) 35/27/24 39/32/29 39/32/29 41/33/30 Dimension (W*H*D) mm 740*210*470 960*210*470 960*210*470 1180*210*470 Packing (W*H*D) mm 910*230*510 1130*230*510 1130*230*510 1350*230*510 Net/Gross weight kg 14/17.5 18/22.5 18/22.5 21.5/26.5 R410A R410A R410A R410A Type EXV EXV EXV EXV 210mm or 270mm or 300mm Capacity Input Heating Capacity Input Drop-Ceiling Only 210 mm (005~028 models) or 270mm (032 to 048 model) or 300mm (052 & 054 models) in height. The EXV is built-in design of the indoor unit, main body without an extra EXV box. Wide capacity range The cooling capacity ranges from 2.2KW to 14.0KW, totally 12 models. External static pressure settings for added flexibility Four speed fan motor (Super high speed is an optional speed) Exchange the wiring connection of ‘SH’ and ‘Hi’ to change the External Static Pressure (ESP). Easy and flexible installation Indoor noise level (H/M/L) Indoor Unit Refrigerant type Refrigerant Control Refrigerant piping Liquid side/Gas side mm ĭ6.35/ĭ ĭĭ ĭĭ ĭĭ Connecting wiring Single wiring mm2 3*0.75 3*0.75 3*0.75 3*0.75 2'ĭ 2'ĭ 2'ĭ 2'ĭ The Electronic Expansion Valve ( EXV ) is fixed inside of the indoor unit Standard air filters placed in an aluminum frame, which is removable downward from bottom. Suction chamber is included as standard equipment Fresh air hole, air inlet/outlet flange are standard for easy duct connection. Return air from back is standard and from bottom as optional with the same connectable duct. Return Air from back Return Air from bottom Standard drain pump 700mm ceiling 'UDLQDJHZDWHUSLSHGLDPHWHU Controller Wireless is standard (Wired controller is optional) Flexible control and convenient for easy service and maintenance The display board is connected with the E-box in factory, easier trouble-shooting by LED display. The Electrical control box can be removed 1m away from the unit, easy to access when needs maintenance. (Should be required by client in advance and done in factory) Standard functional port such as Remote On/Off Dry contact switch and Alarm signal output (220V) MANUAL RUN TIMER DEF ALARM 005~024 model 71 MANUAL OPERATION TIMER DEF./FAN ALARM 028~054 model 72 42VD H112013011 Series Part names Air Intake (Intake room air here) Electric control box Technical Specifications Model Air Outlet (Outlet room air) 42VD006H112013011 Power Supply V-Hz-Ph Cooling 42VD009H112013011 42VD012H112013011 220-240V-50Hz-1Ph kW 2.2 2.8 3.6 Btu/h 7500 9500 12200 W 68 68 72 kW 2.6 3.2 4.0 Btu/h 8900 10900 13600 W 65 65 69 CFM 346(30pa)/316/268/221 346(30pa)/316/268/221 361(30pa)/351/302/252 Pa 10(10~30) 10(10~30) 10(10~30) dB(A) 36/35/32 37/35/32 38.6/37.5/33.8 Dimension (W*H*D) mm 740*210*500 740*210*500 740*210*500 Packing (W*H*D) mm 870*285*525 870*285*525 870*285*525 Net/Gross weight kg 17.5/20 17.5/20 17.5/20 mm ĭ92 ĭ92 ĭ92 R410A R410A R410A Type EXV EXV EXV Capacity Heat Exchanger (Exchange cool air into warm air) Input Smart controls Heating Capacity Input Indoor air flow (SH/H/M/L) Standard wireless remote control WL-12-CM Optional wired control WR-12-CM Indoor external static pressure Std (Min-Max) Indoor noise level (H/M/L) Smart wireless remote controller or optional wired controller with smart, complete control and safety function built in the control systems. Indoor Unit Smart supply airflow Cooling operation Adjust the louver horizontally. Heating operation Adjust the louver down(vertically). The louver is horizontal Adjust left and right. Fresh Air intake hole diameter (round) vertical louver Refrigerant type Refrigerant Control Easy service & maintenance Refrigerant piping Liquid side/Gas side mm ĭ6.35/ĭ ĭ6.35/ĭ ĭ6.35/ĭ Connecting wiring Single wiring mm2 3*0.75 3*0.75 3*0.75 2'ĭ 2'ĭ 2'ĭ 'UDLQDJHZDWHUSLSHGLDPHWHU Easy removal of air filters for cleaning Easy access to indoor unit components Remote on / off function and alarm function 73 Controller Wireless is standard (Wired controller is optional) 74 42VD H112013011 Series 42VD H1120130110 Series Technical Specifications Model 42VD018H112013011 42VD024H112013011 42VD028H112013011 Technical Specifications Model Power Supply Cooling V-Hz-Ph 220-240V-50Hz-1Ph Power supply kW 4.5 5.6 7.1 Btu/h 15300 19100 24200 W 80 80 105 Heating kW 5.0 6.3 8.0 Btu/h 17000 21500 27300 W 80 80 105 CFM 488(30pa)/477/402/338 488(30pa)/477/402/338 663(30pa)/605/549/459 Pa 10(10~30) 10(10~30) 10(10~30) dB(A) 39/37.9/34 39/37.9/34 41.4/39/35 8 9 Btu/h 27,300 30,700 W 231 231 kW 9 10 Btu/h 30,700 34,100 W 231 231 Indoor air flow (/Hi/Mi/Lo) cfm 825(30Pa)/795/687/608 825(30Pa)/795/687/608 Static pressure Std (Min-Max) Pa 20(10~50) 20(10~50) dB(A) 45.4/39.8/37 45.4/39.8/37 Dimension (W x H x D) mm 1140x270x775 1140x270x775 Packing (W x H x D) mm 1355x350x795 1355x350x795 kg 38/46.5 40/48 mm Ɏ Ɏ R410A R410A Cooling Input power Capacity Heating Capacity Input Indoor air flow (SH/H/M/L) Input power Sound level (H/M/L) Indoor external static pressure Std (Min-Max) Indoor noise level (H/M/L) Indoor unit Indoor Unit Dimension (W*H*D) mm 960*210*500 960*210*500 1180*210*500 Packing (W*H*D) mm 1115*285*525 1115*285*525 1335*285*525 Net/Gross weight kg 22.5/26 22.5/26 28/31.5 mm ĭ92 ĭ92 ĭ92 Fresh Air intake hole diameter (round) Net/Gross weight Fresh Air intake hole diameter (round) Refrigerant Type Type Refrigerant control Refrigerant type Refrigerant Control R410A R410A R410A Type EXV EXV EXV Refrigerant piping Liquid side/Gas side mm ĭ6.35/ĭ ĭĭ ĭĭ Connecting wiring Single wiring mm2 3*0.75 3*0.75 3*0.75 2'ĭ 2'ĭ 2'ĭ 'UDLQDJHZDWHUSLSHGLDPHWHU Controller 75 42VD036H112003010 220~240V-1Ph-50Hz kW Capacity Capacity Input 42VD032H112003010 V-ph-Hz Refrigerant piping Connection wiring Liquid side/ Gas side Signal wiring Drainage water pipe diameter Controller mm mm2 mm Electronic Expansion Valve ɎɎ ɎɎ 3×0.75 IDɎ2'Ɏ Wireless is standard (Wired controller is optional) Wireless is standard (Wired controller is optional) 76 VRF Ducted High Static Pressure 42VD-H112011010 Series 7.1 ~ 28.0 kW Cooling 8.0 ~ 31.5 kW Heating 42VD H112003010 Series Technical Specifications Model Power supply 42VD048H112003010 V-ph-Hz 42VD052H112003010 Auto Restart Fresh Air Auto Addressing Cleanable Panel Wireless Controller Anti-Cold Air Function Connectable To Duct Wired Controller 028-032-036-048 42VD054H112003010 056-058-60 220~240V-1Ph-50Hz 140-160-190 Wide capacity range kW 11.2 12.5 14 Btu/h 38,200 42,660 47,800 Input power W 327 355 355 Flexible duct design Rated current A 1.8 1.9 1.9 Four speed fan motor (medium high speed as an option only for 028~055 model) External static pressure can be up to 196Pa (028~055 models) or 250Pa (056~060 models). kW 12.5 13.5 15.5 Btu/h 42,600 46,100 52,900 Input power W 327 355 355 Rated current A 1.8 1.9 1.9 cfm 1199 (30Pa)/1059 /921/824 1258 (30Pa)/1118/967/827 1258 (30Pa)/1118/967/827 Capacity The capacity ranges from 7.1KW to 56KW, totally 12 models. Cooling Capacity Heating Indoor air flow (/Hi/Mi/Lo) the longest distance of air supply is 14m Fresh air in take Min. 420mm Air supply The height of air supply is 6.5m Air return INDOOR UNIT Pa 40 (10~80) 40 (10~100) 40 (10~100) Sound level (sound pressure) dB(A) 48/42/38 48/43/39 48/43/39 Dimension (W x H x D) mm 1140 x 270 x 775 1200 x 300 x865 1200 x 300 x865 Packing (W x H x D) mm 1355 x 350 x 795 1400 x 370 x 925 1400 x 370 x 925 kg 40/48 49/58 49/58 Just exchange the wiring connection of ‘MH’ and ‘Me’.(for 028~055 model) mm Ɏ125 Ɏ125 Ɏ125 Easy and flexible installation R410A R410A R410A Net/Gross weight Fresh Air Intake Size (round) Refrigerant Type Type Refrigerant control Refrigerant piping Connection wiring Liquid side/ Gas side Signal wiring Drainage water pipe diameter Standard Controller mm Electronic Expansion Valve ɎɎ 3×0.75 mm2 mm ɎɎ ,'Ɏ2'Ɏ Wireless remote controller ɎɎ 450mm INDOOR UNIT Static pressure Std (Min-Max) Indoor unit 054-055 The max distance of air supply is about 14m while the height of air supply is about 6.5m. With 420mm (028~055 model) thickness body, the minimum distance above the ceiling is 450mm. Added flexibility with four speed fan The EXV is fixed inside the indoor unit (for 028~055 model), no need extra connection. Standard filter placed in an aluminum frame, which is removable downward from bottom. Flange for air in/outlet duct connection is standard. Flexible control and convenient for easy service and maintenance Standard Wired remote controller, and wireless remote controller is as an option. The display board is connected with the E-box in factory, easier trouble-shooting by LED display. Easy access filters both in rear & bottom Standard functional port such as remote on/off dry contact. Optional drain pump Double-skin drainage pan 750mm ceiling Optional drain pump with 750 mm pumphead. * (for 028~055 model) 77 Double-skin drainage pan provide double protection for ceilings (models 71 to 160 and models 400 to 560) 78 42VD H112011010 Series Part names Air Outlet (Outlet room air) Heat Exchanger (Exchange cool air into warm air) Technical Specifications Air Intake (Intake room air here) Model Power supply Air Outlet (Outlet room air) V-Ph-Hz Cooling Heating Electric control box Electric control box B Electric control box A 7.1 8 9 11.2 14 16 Btu/h 24,200 27,300 30,700 38,200 47,800 54,600 Input power W 240 240 398 518 648 873 Rated current A 1.1 1.1 1.8 2.3 2.7 3.6 kW 8 9 10 12.5 16 17 Btu/h 27,300 30,700 34,100 42,600 54,600 61,400 873 Input power W 240 240 398 518 648 Rated current A 1.1 1.1 1.8 2.3 2.7 cfm 889/823/727 883/822/719 1139/748/889 1246/1147/968 1758/1572/1312 Pa 40(30~ 196) 40(30~ 196) 40(30~ 196) 50(30~ 196) 50(30~ 196) dB(A) 48/46/44 48/46/44.5 52/49/47 52/49/47 53/50/48 mm 952x420x690 952x420x690 952x420x690 952x420x690 1200x400x600 1200x400x600 Packing (W×H×D) mm Net/Gross weight Kg 1090x440x768 45/50 1090x440x768 45/50 1090x440x768 46.5/52.4 1090x440x768 50.6/56 1436x450x768 68/70 1436x450x768 70/77.5 R410A R410A R410A R410A R410A R410A Indoor air flow (Hi/Mi/Lo) Indoor external static pressure Std (Min-Max) One refrigerant system Two refrigerant system Indoor sound level (Hi/Mi/Lo) Dimension (W×H×D) Indoor unit Smart controls 220V-1Ph-50Hz kW Capacity Capacity Air Intake (Intake room air here) 42VD028H112011010 42VD032H112011010 42VD036H112011010 42VD048H112011010 42VD054H112011010 42VD055H112011010 Refrigerant type Type Refrigerant control Refrigerant piping Liquid side/ Gas side Connection wiring Signal wiring Drainage pipe diameter 50(30~ 196) 54/52/50 Electronic expansive valve mm Ɏ9.53/Ɏ15.9 Ɏ9.53/Ɏ15.9 Ɏ9.53/Ɏ15.9 Ɏ9.52/Ɏ15.9 Ɏ9.52/Ɏ15.9 Ɏ9.52/Ɏ15.9 Nb×mm2 3*0.75 3*0.75 3*0.75 3*0.75 3*0.75 3*0.75 ,'Ɏ25/ODɎ ,'Ɏ25/ODɎ ,'Ɏ25/ODɎ ,'Ɏ25/ODɎ ,'Ɏ25/ODɎ ,'Ɏ25/ODɎ mm 2 Wireless remote controller Standard Controller Standard wireless remote control WL-10-CM 3.6 2290/1883/1580 Optional wired control WR-12-CM Technical Specifications Smart wireless remote controller or optional wired controller with smart, complete control and safety function built in the control systems. Model Power supply Smart supply airflow Adjust the louver horizontally. Heating operation Adjust the louver down(vertically). The louver is horizontal Input power W Rated current A Capacity Easy access to indoor unit components Remote on / off function and alarm function 20 68,200 25 85,300 28 95,500 1800 6.6 22.5 1800 6.6 26 1800 6.6 31.5 2700 12.5 45 2700 12.5 50 3400 15.5 53 88,700 1800 6.6 107,500 1800 6.6 153,500 2700 12.5 170,600 2700 12.5 214,960 3400 15.5 A cfm 2512/2226/1882 2519/2248/1833 2590/2182/1883 Indoor external static pressure Std (Min-Max) Pa 140(50~250) 140(50~250) 160(50~250) dB(A) 59/55/52 1425x500x928 59/55/52 1425x500x928 Input power W 40 1,36,800 45 1,53,600 56 1,92,000 4370/3560/2940 4370/3560/2940 5620/4680/3890 200(50~280) 200(50~280) 200(50~280) 61/59/56 1970x668x902.5 61/59/56 1970x668x902.5 63/60/57 1970x668x902.5 2095x800x964 2095x800x964 2095x800x964 mm Packing (WxHxD) mm 1509x550x990 1509x550x990 1509x550x990 Net/Gross weight Kg 115/129 115/129 115/129 232/245 232/245 235/250 R410A R410A R410A R410A R410A R410A Type Liquid side/Gas side Signal wiring Drainage pipe diameter Standard Controller 42VD190H112011010 Dimension (WxHxD) Refrigerant control Connection wiring 42VD160H112011010 59/55/52 1425x500x928 Refrigerant type Refrigerant piping 42VD140H112011010 220V-1Ph-50Hz Indoor air flow (Hi/Mi/Lo) Indoor unit Easy removal of air filters for cleaning 42VD060H112011010 76,800 1800 6.6 Heating Indoor sound level (H/M/L) Easy service & maintenance kW Btu/h Rated current 79 kW Btu/h Adjust left and right. vertical louver 42VD058H112011010 V-Ph-Hz Capacity Cooling Cooling operation 42VD056H112011010 Electronic expansive valve mm Nb×mm mm 2 ɎɎ[ 2 ɎɎ[ ɎɎ[ ɎɎ[ ɎɎ[ ɎɎ[ 3×0.75 3×0.75 3×0.75 3×0.75 3×0.75 3×0.75 ,'Ɏ2'Ɏ ,'Ɏ2'Ɏ ,'Ɏ2'Ɏ ,'Ɏ2'Ɏ ,'Ɏ2'Ɏ ,'Ɏ2'Ɏ Wireless remote controller 80 VRF High wall(S type panel) 42VH Series 2.2 ~ 5.6 kW Cooling 2.4 ~ 6.0 kW Heating VRF High Wall Indoor Units 42VH VRF High Wall indoor unit is the optimum air conditioning solution for places which require high wall installation, elegant appearance and ultimate comfort combined with efficient, quiet operation, optimum air distribution and efficient Indoor Air Quality (IAQ) and environmentally friendly HFC refrigerant R410A. LED Auto Restart Auto Addressing Cleanable Panel Anti-Cold Air Function LED Display Wireless Controller Wired Controller Follow Me DISPLAY Smart LED display VRF Hi Wall VRF Hi Wall S type panel R type panel 2.2 ~ 5.6 kW Cooling 2.4 ~ 6.0 kW Heating 7.1 ~ 9 kW Cooling 8.0 ~ 10 kW Heating 42VH-112000101 42VH-112000102 The front panel and display panel have different colors for choose: white and brown for big panel, blue and brown for small panel, and the other colors can be customized according to the customers’ demands. Easy and flexible installation Model 006 009 012 018 024 Model 028 032 036 Cooling Capacity Heating Capacity 2.2 kW 2.8 kW 3.6 kW 4.5 kW 5.6 kW 7.1 kW 8.0 kW 9.0 kW 2.4 kW 3.1 kW 4.0 kW 5.0 kW 6.0 kW Cooling Capacity Heating Capacity 8.0 kW 9.0 kW 10 kW Compact dimensions and footprint. Flexible multi outlet location of refrigerant piping lines : left / right / back satisfy the need of different rooms. Built-in EXV the indoor unit, compact size, Longer the connection pipe, Gas pipe: 468mm/Liquid pipe: 550mm, more flexible for the installation Adopts new type fixing plate, easy for installation and stable. Smart auto swing louver Smart supply airflow for comfort cool and heat : motorized horizontal air flap with angles as per selected mode for optimal air distribution of supply air temperature and velocity inside air conditioned space. 81 Step Swing Rear Left Right Easy service and maintenance Easy service and maintenance has been realized as the front panel can removed for easy access. Open panel 1 2 3 4 82 Part names Air Intake (Intake room air here) Grounding Screw (In the control box) 42VH 112000101 Series (S Type Panel) Air Outlet Horizontal Louver (Adjust the air-out directions. ) Technical Specifications Air Filter (Filter the dust in the air) Model (Standard ) 42VH006H112000101 V- Ph-Hz Power supply Smart controls 42VH009H112000101 42VH012H112000101 220~240V-1Ph-50Hz kW 2.2 2.8 3.6 Btu/h 7,500 9,500 12,200 W 31 31 31 kW 2.4 3.1 4 Btu/h 8,200 10,500 13,600 W 31 31 31 cfm 309/283/253 309/283/253 309/283/253 dB(A) 35/32/29 35/32/29 35/32/29 Dimension (WxHxD) mm 915 x 290 x 230 915 x 290 x 230 915 x 290 x 230 Packing (WxHxD) mm 1020 x 390 x 315 1020 x 390 x 315 1020 x 390 x 315 Net/Gross weight kg 13.3/16.5 13.3/16.8 (With Heater) 13.3/16.5 13.3/16.8 (With Heater) 13/16.5 13.3/16.8 (With Heater) R410A R410A R410A Capacity Cooling Input power Capacity Heating Input power Standard wireless remote control WL-12-CM Optional wired control WR-12-CM Smart wireless remote controller or optional wired controller with smart, complete control and safety function built in the control systems. Indoor air flow (H/M/L) Indoor sound level (H/M/L) Indoor unit Smart supply airflow Auto-swing When cooling When heating Press SWING button, the louver will swing up and down automatically. Adjust the louver horizontally Adjust the louver downwards (vertically). Refrigerant type Refrigerant control Type Refrigerant piping Liquid side/Gas side Connecting wiring Signal wiring Drainage water pipe diameter Standard Controller Inside Electronic expansive valve mm 6.35/12.7 6.35/12.7 6.35/12.7 Nb×mm2 3x0.75 3x0.75 3x0.75 mm ODɎ ODɎ ODɎ Wireless remote controller Easy service & maintenance Easy removal of air filters for cleaning Air Filter (Filter the dust in the air) Easy access to indoor unit components Remote on / off function and alarm function 83 84 VRF High wall(R type panel) 42VH Series 42VH 112000101 Series (S Type Panel) Auto Restart Auto Addressing 7.1 ~ 9 kW Cooling 8.0 ~ 10 kW Heating Cleanable Panel Anti-Cold Air Function LED Technical Specifications LED Display DISPLAY Wireless Controller Model (Standard ) Power supply Cooling 42VH018H112000101 V- Ph-Hz 42VH024H112000101 Wired Controller 220~240V-1Ph-50Hz kW 4.5 5.6 Btu/h 15,300 19,100 W 44 44 kW 5 6 Btu/h 17,000 20,400 W 44 44 cfm 506/444/371 544/506/444 dB(A) 40/38/34 40/38/34 Dimension (WxHxD) mm 1072 x 315 x 230 1072 x 315 x 230 Packing (WxHxD) mm 1180 x 415 x 315 1180 x 415 x 315 Net/Gross weight kg 15.1/18.8 15.5/19.2(With Heater) 15.1/18.8 15.5/19.2(With Heater) R410A R410A Follow Me Capacity Input power Smart LED display The front panel and display panel have different colors for choose: white and brown for big panel, blue and brown for small panel, and the other colors can be customized according to the customers’ demands. Capacity Heating Input power Indoor air flow (H/M/L) Indoor sound level (H/M/L) Indoor unit Refrigerant type Refrigerant control Type Refrigerant piping Liquid side / Gas side Connecting wiring Signal wiring Drainage water pipe diameter Standard Controller 85 Inside Electronic expansive valve mm 6.35/12.7 9.53/15.9 Nb×mm2 3x0.75 3x0.75 mm ODɎ ODɎ Wireless remote controller Easy and flexible installation Compact dimensions and footprint. Flexible multi outlet location of refrigerant piping lines : left / right / back satisfy the need of different rooms. Built-in EXV the indoor unit, compact size, Longer the connection pipe, Gas pipe: 468mm/Liquid pipe: 550mm, more flexible for the installation Adopts new type fixing plate, easy for installation and stable. Smart auto swing louver Smart supply airflow for comfort cool and heat : motorized horizontal air flap with angles as per selected mode for optimal air distribution of supply air temperature and velocity inside air conditioned space. Step Swing Rear Left Right Easy service and maintenance Easy service and maintenance has been realized as the front panel can removed for easy access. Open panel 1 2 3 4 86 Part names Air Intake (Intake room air here) Grounding Screw (In the control box) 42VH 112000102 Series (R Type Panel) Air Outlet Horizontal Louver (Adjust the air-out directions. ) Model (Standard ) Air Filter (Filter the dust in the air) Power supply 42VH028H112000102 V- Ph-Hz 42VH032H112000102 42VH036H112000102 220~240V-1Ph-50Hz kW 7.1 8 9 Btu/h 24200 27300 30700 Input power W 75 86 86 Rated current A 0.33 0.39 0.39 kW 8 9 10 Btu/h 27300 30700 34100 Input power W 75 86 86 Rated current A 0.33 0.39 0.39 dB (A) 47/43/42 48/43/38 49/43/38 cfm 701/518/401 776/494/377 776/494/377 Dimension (WxHxD) mm 1250x245x325 1250x245x325 1250x245x325 Packing (WxHxD) mm 1345x335x430 345x335x430 345x335x430 Net/Gross weight kg 19.9/25 19.9/25 19.9/25 R410A R410A R410A Capacity Smart controls Cooling Capacity Standard wireless remote control WL-12-CM Optional wired control WR-12-CM Smart wireless remote controller or optional wired controller with smart, complete control and safety function built in the control systems. Heating Sound level (H/M/L) Indoor air flow (H/M/L) Smart supply airflow Auto-swing Press SWING button, the louver will swing up and down automatically. Indoor unit When cooling When heating Adjust the louver horizontally Adjust the louver downwards (vertically). Refrigerant type Refrigerant control Type Refrigerant piping Liquid side/Gas side Connecting wiring Easy service & maintenance Signal wiring Drainage water pipe diameter Electronic expansive valve mm ɎɎ ɎɎ ɎɎ Nb×mm2 3x0.75 3x0.75 3x0.75 mm 2'Ɏ 2'Ɏ 2'Ɏ Easy removal of air filters for cleaning Standard Controller Wireless remote controller Air Filter (Filter the dust in the air) Easy access to indoor unit components Remote on / off function and alarm function 87 88 VRF Floor / Under Ceiling 42VF Series VRF FLOOR / UNDER CEILING INDOOR UNITS 3.6 ~ 14.0 kW Cooling 4.0 ~ 15.5 kW Heating 42VF VRF Floor / Under Ceiling indoor unit is the optimum air conditioning solution for places which require floor or wall or under-ceiling installations, elegant appearance and ultimate comfort combined with efficient and quiet operation, optimum air distribution, and efficient Indoor Air Quality (IAQ). Auto Restart Fresh Air Auto Addressing Cleanable Panel Built-in Drain Pump Anti-Cold Air Function Wireless Controller 42VF is the very latest in slim line technology and art of air conditioning design and environmentally friendly LED Wired Controller HFC refrigerant R410A. 42VF compact dimensions make possible a wide range of applications, even under a window sill. All units can be mounted on the floor, on the wall or under the ceiling. 42VF sizes have been designed for fitting luxury houses and prestigious offices. LED Display DISPLAY Follow Me Smart LED display The front panel and display panel have different colors for choose: white and brown for big panel, blue and brown for small panel, and the other colors can be customized according to the customers’ demands. Easy and flexible installation The ceiling type can be easily installed into a corner of the ceiling even if the ceiling is very narrow It is especially useful when installation of an air conditioner in the center of the ceiling is impossible VRF Floor / Under Ceiling due to a structure such as one lighting The unit can be installed either horizontally on the ceiling or vertically against the wall. Low noise, creates quiet and comfortable environment. Drop ceiling >20 3.6 ~ 14.0 kW Cooling 4.0 ~ 15.5 kW Heating 198mm 42VF-H112000010 Model 012 018 024 028 Cooling Capacity Heating Capacity 3.6 kW 4.5 kW 5.6 kW 7.1 kW 4.0 kW 5.0 kW 6.3 kW 8.0 kW Model 032 036 048 054 8.0 kW 9.0 kW 11.2 kW 14.0 kW 9.0 kW 10.0 kW 12.5 kW 15.5 kW Cooling Capacity Heating Capacity Air Outlet Slim and sleek design starting at just 30kg in weight means quick,easy & neat installation. Low noise operation, lowest to 36 dB(A) Auto swing and wide angle air flow Auto Swing & Wide-angle Airflow 1. The unit has auto horizontal swing and auto vertical swing function, which supplies more even and comfortable airflow. 2. Three air flow speed: high/middle/low, double air guides. 3. Adoption of the electronic expansion valve, ensure precise flow control, as well lower modulation noise when EXV operating. 4. Smoother airflow with less turbulence. Owing to the multiple-blade fan and the air guide design, the airflow is getting smoother and more comfortable. 89 90 Part names 42VF Series Air Outlet Horizontal Louver Air Outlet Horizontal Louver Air Intake Air Intake (Intake room air here) (Intake room air here) Air Filter Air Filter (Filter the dust in the air) (Filter the dust in the air) Technical Specifications Model Power supply Smart controls 42VF012H112000010 42VF018H112000010 42VF024H112000010 42VF028H112000010 220~240V-1Ph-50Hz V-ph-Hz kW 3.6 4.5 5.6 7.1 Btu/h 12,200 15,300 19,100 24,200 W 34 125 125 125 kW 4 5 6 8 Btu/h 13,600 17,000 20,500 27,300 W 34 125 125 125 cfm 383/335/294 471/353/294 471/353/294 471/353/294 dB(A) 40/38/36 43/41/38 43/41/38 43/41/38 Dimension (WxHxD) mm 990x660x206 990x660x206 990x660x206 990x660x206 Packing (WxHxD) mm 1090x745x297 1090x745x297 1090x745x297 1090x745x297 Net/Gross weight kg 28/34 29/35 29/35 29/35 R410A R410A R410A R410A ɎɎ ɎɎ ɎɎ ɎɎ Capacity Cooling Input power Capacity Heating Standard wireless remote control WL-12-CM Optional wired control WR-12-CM Smart wireless remote controller or optional wired controller with smart, complete control and safety function built in the control systems. Smart supply airflow Input power Indoor air flow (Hi/Mi/Lo) Sound level (H/M/L) Indoor unit Auto-swing When cooling When heating Press SWING button, the louver will swing up and down (left and right) automatically. Adjust the louver horizontally. Adjust the louver downwards (vertically). Easy service & maintenance Refrigerant Type Refrigerant piping Liquid side/Gas side mm Connection wiring Signal wiring mm2 3×0.75 Drainage water pipe diameter mm ODɎ16 Standard Controller Wireless remote controller Easy removal of air filters for cleaning Air Intake (Intake room air here) Air Filter (Filter the dust in the air) Easy access to indoor unit components Remote on / off function and alarm function 91 92 VRF Console 42 VF Series VRF Console Technical Specifications Model Power supply 42VF032H112000010 42VF036H112000010 42VF048H112000010 42VF054H112000010 220~240V-1Ph-50Hz V-ph-Hz kW 8 9 11.2 14 Btu/h 27,300 30,700 38,200 47,800 W 143 143 182 182 kW 9 10 12.5 15.5 Btu/h 30700 34100 42600 52900 W 143 143 182 182 Model 006 009 012 018 Cooling Capacity Heating Capacity 2.2 kW 2.8 kW 3.6 kW 4.5 kW 2.6 kW 3.2 kW 4.0 kW 5.0 kW Capacity Cooling Input power 2.2 ~ 4.5 kW Cooling 2.6 ~ 5.0 kW Heating Capacity Heating Input power Indoor air flow (Hi/Mi/Lo) Sound level (H/M/L) Indoor unit cfm 706/530/412 706/530/412 1165/1095/1018 1165/1095/1018 dB(A) 45/43/40 45/43/40 47/45/42 47/45/42 Dimension (WxHxD) mm 1280x660x206 1280x660x206 1670x680x244 1670x680x244 Packing (WxHxD) mm 1380x745x297 1380x745x297 1765x760x330 1765x760x330 Net/Gross weight kg 34/41 34/41 49/58 49/58 R410A R410A R410A R410A ɎɎ ɎɎ ɎɎ ɎɎ Refrigerant type Refrigerant piping Liquid side/Gas side mm Connection wiring Signal wiring mm2 3×0.75 Drainage water pipe diameter mm 2'Ɏ Standard Controller 93 42VC-H112000010 Wireless remote controller 94 Part names VRF Console 42VC Series Installation part 2.2 ~ 4.5 kW Cooling 2.6 ~ 5.0 kW Heating Air flow louver (at air outlet) Display panel Auto Restart Auto Addressing Air inlet (with air filter in it) Cleanable Panel Air flow louver (at air outlet) Anti-Cold Air Function LED Drain pipe LED Display DISPLAY Wireless Controller Wired Controller Smart controls Follow Me Compact unit body, space saving, nice-looking appearance This unit body is very thin and harmonious with room. It is elegant and space saving. The EXV is fixed inside of the indoor unit, Compact unit body. Standard wireless remote control WL-12-CM Easy and flexible installation Optional wired control WR-12-CM Smart wireless remote controller or optional wired controller with smart, complete control and safety function built in the control systems. Can be installed floor or low wall. As a floor standing type, it can be semi or fully cessed Smart supply airflow without loss of capacity. High Comfort Flexible air blow: vertical auto swing and wide angle louvers ensure that warm air reaches the furthest corners of the room and increase the air flow coverage Indoor unit adopts DC motor which has five level fan speed meet different requirements. Adoption of the Fujikoki brand mechanical expansion valve which has 2000 stages element positioning, ensure precise flow control, as well lower modulation noise when EXV operating. Powerful mode can be selected for rapid cooling or heating. COOLING MODE HEATING MODE Auto-swing When cooling When heating Press SWING button, the louver will swing up and down (left and right) automatically. Adjust the louver horizontally. Adjust the louver downwards (vertically). Easy service & maintenance Easy removal of air filters for cleaning Air Outlet Selection Switch especial function filter quick cooling 95 to maintain temp anti-cold air normal operation Easy access to indoor unit components Remote on / off function and alarm function 96 High efficiency filter 42VC Series Built in Formaldehyde nemesis filter Active-carbon and biological anti-virus filter is optional. Two air outlet, Four air inlet Air inlet from 4 directions, there are 2 optional air-outlet ways, Both up and Down air-outlet or up air-outlet only. Technical Specifications 42VC006H112000010 Model Power supply Air Outlet 42VC009H112000010 V- Ph-Hz 42VC012H112000010 42VC018H112000010 220~240V-1Ph-50Hz kW 2.2 2.8 3.6 4.5 Btu/h 7,500 9,500 12,200 15,300 W 20 24 44 44 kW 2.6 3.2 4 5 Btu/h 8,900 10,900 13,600 17,000 W 20 24 44 44 cfm 253/203/135 300/253/135 300/253/135 388/300/235 dB(A) 38/32/26 39/33/27 39/33/27 42/39/36 15/20 15/20 Capacity Cooling Input power Capacity Heating Input power Air Inlet Indoor air flow (H/M/L) Bottom, Top, and right/left side, for better ventilation. Indoor sound level (Hi/Mid/Lo) Indoor unit Quiet Design Five speeds indoor unit, Low noise and Energy saving. Dimension (WxHxD) mm 700*600*210 Packing (WxHxD) mm 810*710*305 Net/Gross weight kg Refrigerant type 14/19 15/20 R410A Type EXV Refrigerant piping Liquid side/Gas side mm Ɏ6.35/Ɏ12.7 Connecting wiring Signal wiring mm2 3×0.75 Drainage water pipe diameter mm 2'Ɏ6 Refrigerant control Standard Controller Wireless remote controller Low noise operation, lowest to 26dB(A) 97 98 VRF Floor Standing 42 VS Series (Exposed) VRF FLOOR STANDING 2.2 ~ 8 kW Cooling 2.4 ~ 9 kW Heating VRF Floor Standing Auto Restart Cleanable Panel Auto Addressing Anti-Cold Air Function Follow Me LED LED Display DISPLAY Exposed floor standing with front air intake ntake Exposed 42VS-H112002010 Concealed 42VS-H112003010 Cooling Capacity Heating Capacity Model Cooling Capacity Heating Capacity Concealed floor standing 42VS-H112003010 Easy and flexible installation 2.2 ~ 8.0 kW Cooling 2.4 ~ 9.0 kW Heating Model 42VS-H112002010 20 0 Floor standing types can be hung on the wall or installed on the floor. The former can make cleaning and maintenance much more easily. Running the piping from the back allows the unit to be hung on walls. Cleaning under the unit, where dust tends to accumulate, is considerably easier. 006 009 012 018 2.2 kW 2.8 kW 3.6 kW 4.5 kW Easy service and maintenance 2.4 kW 3.2 kW 4.0 kW 5.0 kW Filters are equipped as standard accessory, and it can be removed and cleaned easily due to sophisticated design as well as the removable blades. Streamlined appearance makes it much more harmonious with the decoration. All metal parts are made of commercial grade galvanized steel, providing maximum protection against corrosion. 024 028 032 5.6 kW 7.1 kW 8.0 kW 6.3 kW 8.0 kW 9.0 kW So compact that it fits into even a tiny space The body is concealed in the skirting-wall to pursue harmony with the interior. With 212mm depth of body dimension, it can be installed in the perimeter zone. Low noise level due to special installation method for not exposed in the room space. 99 100 Part names Air out, air out louver (Adjust the air-out direction) 42VS H112002010 Series (Exposed) Air Intake (Intake room air here) 42VS-H112002010 Version I Vertical unit with casing,with air intake from front and air outlet on top, for installation on a wall or on feet on the floor. Exposed floor standing with front air intake Technical Specifications Model ( Front air intake ) Power supply Air outlet (Outlet room air) 42VS006H112002010 42VS012H112002010 42VS018H112002010 220~240V-1Ph-50Hz V- Ph-Hz kW 2.2 2.8 3.6 4.5 Btu/h 7,500 9,500 12,200 15,300 W 40 40 49 49 kW 2.4 3.2 4 5 Btu/h 8,200 10,900 13,600 17,000 W 40 40 49 49 cfm 312/268/235 335/285/248 367/307/221 388/319/259 dB(A) 36/33/29 36/33/29 37/34/30 37/34/30 Dimension (W×H×D) mm 1000x220x625 1000x220x625 1200x220x625 1200x220x625 Packing (W×H×D) mm 1090x685x313 1090x685x313 1290x685x313 1290x685x313 kg 30/35 30/35 37/43 37/43 Capacity Cooling Input power Capacity Heating Electric control box Input power Air intake (Intake room air here) Indoor air flow (H/M/L) Air filter (Filter the dust in the air) Indoor sound level (Hi/Mid/Lo) Smart controls Indoor unit Net/Gross weight Refrigerant type Standard wireless remote control WL-12-CM 42VS009H112002010 Optional wired control WR-12-CM Smart wireless remote controller or optional wired controller with smart, complete control and safety function built in the control systems. R410A Refrigerant control Type Electronic expansion valve mm ɎɎ Connecting wiring Signal wiring mm2 3×0.75 Drainage water pipe diameter mm 2'Ɏ Refrigerant piping Standard Controller Liquid side/Gas side Wireless remote controller Smart supply airflow Auto-swing When cooling When heating Press SWING button, the louver will swing up and down (left and right) automatically. Adjust the louver horizontally. Adjust the louver downwards (vertically). Easy service & maintenance Easy removal of air filters for cleaning Easy access to indoor unit components Remote on / off function and alarm function 101 102 42VS H112003010 Series (Concealed) 42VS H112002010 Series (Exposed) 42VS-H112002010 Exposed version with air intake from front Technical Specifications 42VS024H112002010 Model ( Front air intake ) Power supply V- Ph-Hz Capacity Cooling Input power kW 42VS028H112002010 7.1 Model 42VS024H112002010 Power supply 220~240V-1Ph-50Hz 5.6 42VS-H112003010 Technical Specifications V- Ph-Hz 19,100 24,200 27,300 W 95 139 139 kW 6.3 8 9 Capacity Btu/h 21,500 27,300 30,700 Input power W 95 139 42VS012H112003010 42VS018H112003010 220~240V-1Ph-50Hz 2.2 2.8 3.6 4.5 Btw/h 7,500 9,500 12,200 15,300 W 40 45 49 50 kW 2.4 3.2 4 5 Btw/h 8,200 10,900 13,600 17,000 W 40 45 49 50 cfm 312/268/235 335/285/248 367/307/220 388/319/259 Pa 0/0/10 0/0/10 0/0/10 0/0/10 dB(A) 36/33/29 36/33/29 37/34/30 37/34/30 Dimension (WxHxD) mm 840/212/545 840/212/545 1036x212x545 1036x212x545 Packing (WxHxD) mm 925x640x305 925x640x305 1125x640x305 1125x640x305 Net/Gross weight kg 22/25.5 22/25.5 29.5/34 29.5/34 Capacity Cooling Input power Heating 42VS009H112003010 kW 8 Btu/h 42VS006H112003010 Capacity 139 Heating Indoor air flow (H/M/L) Indoor sound level (Hi/Mid/Lo) cfm dB(A) 677/571/489 812/647/512 784/713/602 41/35/31 44/39/33 44/39/33 Indoor air flow (H/M/L) 1500x220x625 Dimension (W×H×D) mm Packing (W×H×D) mm 1500x220x625 1500x220x625 Indoor external static pressure (Hi) Indoor sound level (Sound pressure)(Hi/Mi/Lo) 1500x685x313 Indoor unit Input power 1500x685x313 1500x685x313 Indoor unit Net/Gross weight 44/50 44/50 44/50 kg Refrigerant type Refrigerant type Refrigerant control Type Electronic expansion valve mm ɎɎ Connecting wiring Signal wiring mm2 Drainage water pipe diameter mm Refrigerant piping Standard Controller 103 R410A R410A Liquid side/Gas side Refrigerant control Type Electronic expansion valve ɎɎ ɎɎ Refrigerant piping Liquid side/Gas side mm 3×0.75 Connecting wiring Signal wiring mm2 3×0.75 ODɎ 16 Drainage water pipe diameter mm ODɎ 16 Wireless remote controller Standard Controller ɎɎ ɎɎ Wireless remote controller 104 VRF FRESH AIR PROCESSING UNIT 42VS H112003010 Series (Concealed) VRF Fresh Air Processing Unit 42VS-H112003010 Technical Specifications 42VS024H112003010 Model Power supply V- Ph-Hz 42VS028H112003010 42VS032H112003010 220~240V-1Ph-50Hz kW 5.6 7.1 8 Btw/h 19,100 24,200 27,300 W 95 139 139 kW 6.3 8 9 Btw/h 21,500 27,300 30,700 W 95 139 139 Indoor air flow (H/M/L) cfm 676/570/488 811/647/512 783/713/602 Indoor external static pressure (Hi) Pa 0/0/10 0/0/10 0/0/10 Capacity Cooling Input power Capacity 12.5 ~ 28 kW Cooling 10.5 ~ 22 kW Heating Heating Input power Indoor sound level (Sound pressure)(Hi/Mi/Lo) Indoor unit dB(A) 41/35/31 44/39/33 44/39/33 Dimension (WxHxD) mm 1336x212x545 1336x212x545 1336x212x545 Packing (WxHxD) mm 1425x640x305 1425x640x305 1425x640x305 Net/Gross weight kg 36/40 36/40 36/40 Refrigerant type Type Electronic expansion valve Refrigerant piping Liauid side/Gas side mm ɎɎ Connecting wiring Signal wiring mm2 3×0.75 Drainage water pipe diameter mm 2'Ɏ 105 Model Cooling Capacity Heating Capacity 050 054 056 058 060 12.5 kW 14 kW 20.0 kW 25.0 kW 28.0 kW 10.5 kW 12 kW 18.0 kW 20.0 kW 22.0 kW R410A Refrigerant control Standard Controller 42VD-H112211010 Wireless remote controller 106 VRF Fresh Air Processing unit 42VD Series 12.5 ~ 28 kW Cooling 10.5 ~ 22 kW Heating 42VD H112211010 Series Technical Specifications Model Power supply 42VD050H112211010 42VD054H112211010 42VD056H112211010 42VD058H112211010 42VD060H112211010 220-240V-1Ph-50Hz V-Ph-Hz kW 12.5 14 20 25 28 Btu/h 42,600 47,800 68,200 85,300 95,500 Input power W 568 568 1,300 1,350 1,350 Rated current A 2.4 2.4 5.3 5.6 5.6 kW 10.5 16 18 20 22 Btu/h 35,800 54,600 61,400 68,200 75,000 Input power W 568 568 1,300 1,350 1,350 Rated current A 2.4 2.4 5.3 5.6 5.6 Indoor air flow (Hi/Mid/Lo) cfm 1000/795/618 1000/795/618 1854/1560/1354 1942/1677/1471 1942/1677/1471 Indoor external static pressure Std (Min-Max) Pa 50(30~220) 50(30~220) 140(50~260) 140(50~260) 140(50~260) dB(A) 54/52/50 54/52/50 54/53/51 55/54/52 55/54/52 Dimension (W×H×D) mm 1368x420x691 1368x420x691 1443x470x810 1443x470x810 1443x470x810 Packing (W×H×D) mm 1436x450x768 1436x450x768 1509x550x990 1509x550x990 1509x550x990 Net/Gross weight Kg 69.5/76 69.5/76 115/125 115/125 115/125 R410A R410A R410A R410A R410A Capacity Cooling(*1) Creating comfortable and healthier climate Fresh air are introduced into the environment, improved air quality Create comfortable and healthier climate Capacity 100% Fresh air processing unit the longest distance of air supply is 14m Both fresh air filtration and heating/cooling can be achieved in a single system. Indoor units and fresh air processing unit can be connected to the same refrigerant system, resulting in enhanced design flexibility and a significant reduction in total system costs. Fresh air in take INDOOR UNIT Air supply The height of air supply is 6.5m Heating(*2) Air return Indoor sound level(*3) (Sound pressure)(Hi/Mid/Lo) Indoor unit High external static pressure External static pressure can be up to 220Pa(052~054 models) and 260Pa(056~060 models) for more flexible duct applications. The maximal distance of air supply is about 14m and the maximum height of air supply is about 6.5m. Innovative air supply technology for excellent room temperature control. Layout Example Refrigerant control Electronic expansion valve Type Refrigerant piping Liquid side/Gas side Connection wiring Signal wiring Drainage pipe diameter mm ɎɎ ɎɎ ɎɎ ɎɎ ɎɎ Nb×mm2 3*0.75 3*0.75 3x1.0 3x1.0 3x1.0 mm2 Ɏ Ɏ Ɏ Ɏ Ɏ Standard Controller Outdoor Units Indoor Unit Wireless remote controller Notes: 1 .Nominal cooling capacities are based on the following conditions: outdoor air temp.: 33ºC DB, 24ºC WB, equivalent ref. piping: 8m (horizontal) 2. Nominal heating capacities are based on the following conditions: outdoor air temp.: 0°CDB, -1°CWB, equivalent ref. Piping: 8m (horizontal) 3. Sound level is measured 1.4m from the air out-let. external static pressure are based on high speed indoor air flow. Specifications are subject to change without prior notice for product improvement. Indoor Unit * * Connection Conditions: The following restrictions must be observed in order to maintain the indoor units connected to the same system. Outdoor Air processing unit Air-conditioning 107 Refrigerant type Outsideair supply * * * When outdoor-air processing units are connected, the total connection capacity must be within 50% to 100% of that of the outdoor units. When outdoor-air processing units and standard indoor units are connected, the total connection capacity of the outdoor-air processing units must not exceed 30% of that of the outdoor units. Outdoor-air processing units can be used without indoor units. 108 VRF AHU KIT AHUKZ SERIES CONTROL DEVICES Technical Specifications Model AHUKZ-01B Power supply AHUKZ-02B 220~240V-1Ph-50Hz Indoor unit capacity kW IP-class 20~360 IPX0 IPX0 IPX0 ĭ8/ĭ8 ĭ12.7/ĭ12.7 ĭ15.9/ĭ15.9 mm Dimension mm 375×350×150 Packing dimension mm 490×240×420 HP AHUKZ-01B 3.2 4 5 AHUKZ-02B 6 8 10 12 Type 360~560 9~20 Piping size (in/out) Capacity AHUKZ-03B Individual Controller WL-12-CM *6: Standard individual controller is WL-12-CM, other individual controller need to customise. AHUKZ-03B 14 Remote controller 16 18 20 Wired controller WR-29-CM WR-12-CM AHU Kit should be installed vertically as shown below: Centralized Controller CRF-10-CM WCRF-10-CM CRC-10-CM CRM-30-CM-B Install vertically BMS Gateway BACNET Gateway MODBUS Gateway Wrong installation way Vertically (¥ ) LONWORK Gateway Horizontally (×) Wiring diagram between indoor and outdoor units Network Control Software &Hardware Ued for network control and power fee calculation. Accessories Hotel card Infra-red NIM ODU alarm module Data converter digitalpower meter Features • • • 109 Built in expansion valve Maximum 4 AHU control box can be combined (maximum capacity 80HP) Self diagnosis function 110 CONTROL SYSTEMS Building Management System Centralized Control Connectable to various sized BMS/BAS Individual control Network Monitoring Controller 485A-I Wire controller WR-10-CM WR-12-CM MD-NIM01 Remote controller Weekly Schedule Centralized Controller WL-12-CM WCRF-10-CM Accessories Card-key Interface Indoor Centralized Controller Lonwork Gateway MD-NIM05 CRF-10-CM Outdoor Centralized Controller Card-key Infared Sensor CRC-10-CM Web Monitoring Tool Bacnet Gateway Note: The wires in the diagram show the signal flows only, while not represent the actual connecting ways. *Combined ON/OFF function can be customized from us. 111 MD-NIM05 Combined ON/OFF* Bacnet Gateway INFARED SENSOR Outdoor units nits 112 Comparison of Controllers Item WIRED CONTROLLER Remote Model name MAX. controllable IDU Wired Controller Centralized Controller 4th-generation Monitoring System WL-12-CM WR-12-CM CRF-10-CM WCRF-10-CM 3GNS-10-CM 1 1 16/64 1024 Wired Controller On/Off WR-12-CM Operation mode setting AC control function Heating mode Functions Fan speed setting Follow me WR-29B-CM Room temp. setting With the FOLLOW ME function, WR-12-CM the Vertical swing wired controller can detect the air temperature at the Sensor part Horizontal swing user’s altitude instead that of the ceiling or the floor. Economic mode This Group setting helps making the room environment comfortable and the temperature accurate. FOLLOW ME Button Key lock Backlight Display Current time Built-in timer RC prohibition Built-in daily timer offers the convenience of automatically starting and turning down the air conditioners according to the set time. Address Error code 24°C ON 0 3 6 9 12 15 OFF 18 21 Time The inddor unit is set to work at automode from 8:00 to 20:00 Period Week On/Off per day 4 On/Off per week 28 Timer On/Off timer Easy connection Easy installation Wired controller conveniently connects to the indoor unit’s display panel with the appropriative connecting wire. The wired controller allows to be installed into the wall by fixing the bottom directly or fixing the device to a mounting cabinet. FOLLOW ME Display panel Emergent stop WR-10-CM Wire controller Emergent start Control Address setting Indoor main board BMS access Control via internet : Each of this kind of controller has the corresponding functions. : This function is optional. : This function is not available through the corresponding controller. Model Dimensions Power 113 WR-10-CM WR-12-CM WR-90-CM 120×120×15 120×120×15 90×86×13 Power from the display panel. Extra power is unnecessary. 114 CENTRALIZED CONTROLLER INDOOR CENTRALIZED CONTROLLER WEEKLY SCHEDULE CENTRALIZED CONTROLLER CRF-10-CM WCRF-10-CM front appearance side appearance front appearance Functions Centralized control Three lock modes CRF-10-CM is a multifunctional device which is able to control up to 64 indoor units. And the connection length can be up to 1,200m. With the newly designed machines, this device connects to the master outdoor unit, making the centralized wiring quite simple.The 2 ways of connecting is as follows: Centralized controller CRF-10-CM provides a superior way to manage the indoor units. Users are able to make their own choice from locking the wireless controller, locking the running mode or lock the CRF-10-CM's keyboard, as they wish. X,Y,E P,Q,E X,Y,E P,Q,E X,Y,E P,Q,E X,Y,E Locking Locking Locking Centralized Running Remote Keyboard Controller Mode Controller X,Y,E Single/unified control mode Indoor unit working status display CRF-10-CM displays both the indoor units working status and the error codes. Via checking the error codes table in the user manual, users can easily find out the malfunction and call the repairman. Error code or protection code The control object can be either single or all, making the controlling operation convenient and easy. With the operation signal feedback, users ensure their machines work at the precise working mode. side appearance Functions Weekly schedule 8:00 WCRF-10-CM allows up to 64 indoor units making the weekly schedule. Users can set up to 4 periods per day and select the desired running mode and room temperature. The operating object could be any indoor unit or all the indoor units. 16:00 23:59 Sun 28°C 22°C Mon 26°C 22°C 17°C 23°C Tue 26°C 22°C 17°C 23°C Wed 26°C 22°C 17°C 23°C Thu 26°C 22°C 26°C Fri 26°C 22°C 26°C Sat 28°C off 24°C 24°C Three lock modes Single/unified control mode Centralized controller WCRF-10-CM provides a superior way to manage the indoor units. Users are able to make their own choice from locking the wireless controller, locking the running mode or lock the WCRF-10-CM’s keyboard, as they wish. The control object can be either single or all, making the controlling operation convenient and easy. With the operation signal feedback, users ensure their machines work at the precise working mode. OPR.UNSUCCESS Locking Locking Locking Centralized Running Remote Keyboard Controller Mode Controller OPR.UNSUCCESS Connecting status matrix # ERROR INLINE ON OFF PROTECT MODE 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 AUTO (1.6) GROUP QUERY RUN SET #GROUPALL 00+ 16+ SET.TEMP ROOM.TEMP T3 Hr ON OFF T2A T2B 32+ FAN Hr 48+ OPR.UNSUCCESS Indoor unit working status display Access to network monitoring MAX.64 WCRF-10-CM displays both the indoor units working status and the error codes. Via checking the error codes table in the user manual, users can easily find out the malfunction and call the repairman. Error code or protection code GROUP QUERY RUN SET #GROUPALL CRF-10-CM Dimensions(H×W×D)(mm) 170×110×70 Power 115 198-242V(50/60Hz) Dimensions(H×W×D)(mm) Power 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 AUTO 00+ 16+ Hr ON Model MODE SET.TEMP T3 Model # ERROR INLINE ON OFF PROTECT ROOM.TEMP CRF-10-CM Connecting status matrix (1.6) CRF-10-CM is able to bridge up to 64 indoor units to the network monitoring system and the building management system. OFF T2A T2B 32+ FAN Hr 48+ OPR.UNSUCCESS WCRF-10-CM 170×110×70 198-242V(50/60Hz) 116 CENTRAL CONTROL SOFTWARE Multiple functions 4th generation system is able to realize the remote control of indoor units. The command of indoor unit can be both the normal ones, such as changing the running modes, adjusting the temp., timer functions, and the higher class command, such as excluding the other controllers to realize unique PC control. 4TH GENERATION MONITORING SYSTEM 4GNS-10-CM 4GNS-10-IF Functions Normal Group Unique Funtions Settings PC Control Running 3rd generation status monitoring Reports system Running parameter display Friendly user interface 4th generation system can synchronize both the indoor 4th generation monitoring system offers a simple and explicit user interface to allow realize its functions simply. 4th generations monitoring system is able to control up 1024 indoor units and 512 outdoor units. and outdoor units’ running status and parameters, to realize the visual control of the refrigerant system. Moreover, the 4th generation system records the running Group definition 4th status and error information of the refrigerant system, which helps the maintenance accurate and easy. The structure of the building The layout drawing of the floor makes it easy to select the desired unit. Click the unit to operate Electricity charge apportionment With the appropriate devices, 4th generation system can record the total electricity consumption and the on/off time of the outdoor units. And with the indoor units’ actual cooling power, the software intelligently distributes the power consumption to each indoor unit. Moreover, the software can generate the electricity charge bills and the bill of the indoor units’ on/off time, which is a basis of the power consumption. Room01 (60kWh) 40% Actual Usage Rate 30% 35% 35.3% 35% 35.1% Displayed Rate power distribution 20% 20% 10% Room04 (210kWh) Room02 (120kWh) 19.4% 10.2% 10.2% 0% Room01 Room02 Room03 Room04 Room03 (210kWh) The principle of the electricity distribution Room 01 electric power consumption 117 Demand capacity of Room01 Total demand capacity of indoor units Total power consumption 118 HOTEL CARD KEY INTERFACE MODULE 3-PHASE PROTECTOR HC-10-CM GMR-32B Cooperate with the wired controller to realized humanistic automatic control. High voltage power is unnecessary, making the device safe and steady. Auto-restart function inside. Detect the power condition and make the corresponding protecting action. Protect the compressor from being damaged. Automatically distinguish the power supply’s abnormal type and automatically recover. Installation example Excellent reliability Electrical wiring The protector protects the entire system from power supply problems, Moreover, the protector can automatically recover from switching off status. Multiple protections WR-10-CM WR-10-CM GMR-32B protects the entire system from many kinds of power supply problems. HC 10 CM HC-10-CM HC-10-CM 220V Protection KM Action Time Phase reverse Card key Card key Type AC contactor Wired controller is necessary in this card-key system. 0.5S Dynamic/static phase loss 1S - 7S T 30S Over/under voltage Model Phase imbalance HC-10-CM Action condition Operating voltage is over setting voltage Voltage deviation is over 10% 5S Fail-safe Dimensions(H*W*D)(mm) Input power fails, relay does not act 86×72.8×15.5 Power Powered from display panel. Extra power unnecessary. INFRARED SENSOR CONTROLLER Model GMR-32B Dimensions(H×W×D)(mm) 63×43×79 Power 200-500V(50/60Hz) HC-18-CM DIGITAL POWER METER Automatically adjust the room environment. Automatically extend the shutting down time, avoiding frequent ON/OFF. Graceful appearance accommodates itself to the different buildings. Calculate the power consumption. Do not need adjustment after working for long periods. One outdoor unit corresponds one digital power meter. Low power consumption Infra-red inductive controller WR-10-CM WR-10-CM WR-10-CM Wire controller Infra-red sensor Display panel CN3 HC-18-CM 8 CM MD-NIM09/E HC-18-CM 8 CM CN2 CN1 S1 Infra-red inductive control box Indoor main board The digital power meter works at low consumption. The working power is as follows: Voltage circuit: less than 2W/10VA Current circuit: less than 2.5VA HC-18-CM works k together with the wired controller. Model Dimensions(H×W×D)(mm) Power 119 Indications and installation 15mm long crack 72 LCD Impulse A phase B phase C phase 201 Electrical wiring 230 Installation example DTS634/DTS636 131 145 HC-18-CM Senor part: 46×30×25.6, Control box: 86×72.8×15.5 Powered from display panel. Extra power unnecessary. Model Dimensions(H×W×D)(mm) Power The digital power meter is checked to be up to standard after it is manufactured, so it's able to work at once on the project site. The lights indications and the installation are as the left. DTS634 / DTS636 230×145×72 200V-500V(50Hz) 120 SELECTION SOFTWARE ACCESSORIES Carrier has developed a new program to design VRF systems which meets the consultants’ and distributors’ requirements. The software provides a quick and convenient selection for users, which Accessory Shape Model Description BJC-02-CM (i) For two outdoor units combination at installation location BJC-03-CM (i) For three outdoor units combination at installation location supports multi-languages. Greatly improving the VRF INVERTER selection efficiency and simplifying the procedure. Project Load calculation It contains project information such as project name, nation, location, etc. Detailed meteorologic datas make the machines selected fit for the local environment well. It provides two calculation methods. Directly decide the room load or input the detailed parameters such as room area, estimated cooling/heating load index, heating capacity and cooling capacity. A/C selection Piping drawing There are 15 types and 100 models of indoor units and all kinds of different power of outdoor units for choosing. Piping drawing shows the detailed layout of an A/C system and parameters of piping and branch distributors. BJC-04-CM (i) For four outdoor units combination at installation location Controller selection Report output BJF-224-CM (i) A* < 16.6 kW To select the right central controller for indoor units and outdoor units; wireless or remote controller for indoor units. Output a total report of selection project in word or PDF format. BJF-330-CM (i) $N: BJF-710-CM (i) N:$N: BJF-1344-CM (i) N:$N: BJF-E1344-CM (i) N:$N: BJF-1500-CM (i) 180 kW > Branch joint for outdoor unit Branch joint for indoor unit VRF INVERTER SBH-01 Drain pump 121 SBH-03 For low/high static pressure duct type indoor SBH-04 unit(Option) 122 Refrigerant Distributors Branch list of outdoor unit BJC-02-CM Outdoor branch Branch list of indoor unit 0D:31.8 ID:25.4 Liquid Side Joints Q2 ID:31.8 ID:9.5 OD:12.7 0D:31.8 ID:25.4 Q1 OD:9.5 ID:9.5 ID:6.4 OD:19.1 (ID:15.9) ID:12.7 Gas side ID:41.3 Q5 ID:41.3 ID:9.5 ID:12.7 OD:12.7 0D:34.9 ID:41.3 ID:44.5 ID:31.8 Q6 0D:31.8 ID:15.9 ID:19.1 OD:15.9 ID:15.9 Q3 Q1 ID:38.1 ID:31.8 ID:34.9 ID:25.4 0D:15.9 0D:15.9 ID:15.9 ID:12.7 ID:19.1 ID:12.7 ID:19.1 Y2 Y1 0D:15.9 Y2 Y6 Y1 ID:15.9 ID:15.9 0D:15.9 ID:12.7 ID:12.7 ID:19.1 ID:22.2 ID:19.1 Liquid side 0D:19.1 Y3 Y1 ID:22.2 ID:15.9 ID:19.1 ID:12.7 ID:15.9 0D:15.9 Y7 Y1 ID:15.9 ID:15.9 0D:15.9 ID:12.7 ID:22.2 0D:25.4 ID:25.4 Y5 Y8 ID:22.2 ID:15.9 Y1 ID:25.4 ID:22.2 OD:22.2 ID:22.2 Y7 0D:22.2 ID:22.2 ID:19.1 ID:22.2 OD:19.1 ID:19.1 OD:19.1 OD:22.2 (ID:19.1) OD:22.2 (ID:19.1) ID:15.9 ID:12.7 ID:15.9 ID:15.9 0D:15.9 0D:31.8 Y6 Y1 ID:15.9 ID:31.8 0D:15.9 ID:15.9 Y6 OD:19.1 (ID:15.9) ID:12.7 ID:9.5 0D:31.8 ID:25.4 ID:19.1 (ID:15.9) ID:12.7 ID:15.9 ID:15.9 ID:12.7 ID:44.5 ID:41.3 OD:41.3 ID:31.8 ID:31.8 ID:31.8 ID:25.4 ID:15.9 ID:38.1 ID:34.9 OD:34.9 ID:34.9 Q1 ID:38.1 ID:19.1 ID:44.5 ID:41.3 ID:38.1 Q5 OD:15.9 (ID:12.7) ID:9.5 ID:6.4 OD:28.6 ID:19.1 ID:22.2 OD:34.9 ID:41.3 ID:34.9 0D:31.8 ID:34.9 OD:12.7 OD:15.9 ID:9.5 (ID:12.7) ID:9.5 ID:31.8 ID:28.6 OD:28.6 ID:28.6 ID:6.4 OD:22.2 ID:22.2 OD:28.6 (ID:19.1) ID:15.9 ID:34.9 ID:25.4 ID:34.9 Y4 ID:34.9 ID:38.1 ID:31.8 0D:31.8 ID:31.8 ID:12.7 OD:12.7 ID:9.5 ID:6.4 ID:25.4 ID:22.2 OD:22.2 ID:22.2 OD:22.2 (ID:19.1) ID:15.9 ID:12.7 ID:19.1 ID:15.9 OD:34.9 ID:28.6 ID:28.6 ID:22.2 ID:22.2 ID:19.1 ID:31.8 ID:31.8 ID:12.7 ID:15.9 0D:15.9 ID:12.7 ID:6.4 ID:6.4 Oil balance pipe P 123 Q7 ID:31.8 ID:31.8 Y2 BJF-E1344-CM ID:38.1 Q1 Q1 BJF-1344-CM Q7 Q2 Q4 BJF-710-CM Q2 ID:31.8 ID:9.5 OD:9.5 ID:6.4 ID:15.9 ID:19.1 OD:19.1 ID:19.1 OD:19.1 (ID:15.9) ID:12.7 Q1 0D:34.9 0D:34.9 ID:25.4 BJF-330-CM ID:31.8 ID:25.4 0D:31.8 ID:25.4 BJF-224-CM BJC-04-CM 0D:31.8 Gas side joints Name BJC-03-CM P(2pcs) 124 Notes 125 Notes 126
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement