- Operating instructions
advertisement
Operating
Instructions
Cordless Ultra-Lok
Table of Contents
Warranty, Safety Guidelines, Contents
Setup Instructions
Settings
Parts List
Troubleshooting
Assembly Instructions
Clamp Application
Free-End
Preformed
Maintenance
Blade Change
Tool
9-10
11
12-13
14
2
3-4
5
8
6
7
UL4000-B
UL4000-B220
Ultra-Lok
Tool
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
P: 1-800-525-0758
F: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 1 of 14
Document # P07986 Rev. E
© Copyright
BAND-IT-IDEX, Inc. 2010
All rights reserved
Warranty, Safety
Guidelines, Contents
UL4000-B
UL4000-B220
Ultra-Lok
Tool
Warranty
Refer to website for warranty information: http://www.band-it-idex.com/warranty.html
NOTE: Any performance data published herein is based on laboratory tests, which cannot duplicate conditions that may be encountered in field installations. Such conditions may vary results substantially from those shown (such as abuse in handling and installation, failure to follow recommended handling and installation practices, abnormal environmental conditions, disregard of operating instructions for BAND-IT tools or non-recommended combinations of BAND-IT products). BAND-IT cannot be responsible for performance characteristics from such variables.
Safety Guidelines
When applying clamps, care should be taken to make certain that fingers are not in the way of the clamp being applied. Tensioning the clamp can be stopped immediately by releasing the trigger. Detailed instructions are in this manual and the operator is advised to read it and become familiar with operating the tool.
IMPORTANT: When clamping a hose end, remember that a tighter clamp keeps the fitting more secure, but excess tension could damage the hose. Fitting stem must have prominent barbs for proper retention inside the hose, but must not be sharp to prevent cutting into the hose. Hose, fitting and clamp must be compatible with each other and the environment used in. If in doubt, consult the hose or fitting manufacturer or call BAND-IT.
Clamping objects other than hose requires similar precautions.
CAUTION: Improperly tightened clamps may result in dangerous hose assemblies, which could cause injuries or property damage.
CAUTION: Abuse or use of a hose outside the manufacturers recommended conditions may cause it to quickly deteriorate and become a safety hazard. This could result in serious injury or property damage. Inspect and test hose assemblies frequently.
Contents
Assembled
Tool
Additional Battery
Pack
Battery Charger
Parts List
Assembled Tool
Battery Charger
Additional Battery Pack
Syringe Pouch
Hex Key, 5/32"
Hex Key, 3/16"
Manuals, Tool & Drill
Carrying Case
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
P: 1-800-525-0758
F: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 2 of 14
Document # P07986 Rev. E
© Copyright
BAND-IT-IDEX, Inc. 2010
All rights reserved
Setup
Instructions
UL4000-B
UL4000-B220
Ultra-Lok
Tool
Warning:
Always wear safety glasses when operating this tool and keep both hands and clothing away from clamp being tensioned. Squeezing force of 3/4" clamp can reach as high as 2 tons. Never attempt to clamp objects which can shatter, or otherwise cause bodily harm.
1.
Read safety instructions and operator‟s manual for the Bosch 37618-01 or Bosch GSR 18 VE-2LI cordless Drill.
Check to make sure drill is properly set up for use with Band-It Ultra-Lok
tool as follows:
---- Drill spindle has a Clutch (Band-It # M21790) installed in place of the Drill Chuck.
---- See page 5 for recommended Drill speed and torque settings.
2. Charge Drill Battery according to the operator‟s manual.
3. To mount the Drill onto the Band-It Ultra-Lok
Tool: First, using the two #10-32 x 3/8" screws, tighten the Tool Body
Adapter on the Tension Tool with 20
–30 in-lbs. Place the Adapter Clamp over the Tool Body Adapter. Orient the Drill
Clutch Pin horizontally (see p. 4). Carefully place the Tool Body Adapter over the Drill Torque Dial. If there is any additional resistance, gently rotate the Tension Tool until the Tension Screw engages with the Drill Clutch (see p. 4), and rotate Tension Tool to the desired orientation. Position Tool Body Adapter to butt-up against the shoulder of the handle mounting surface. Slide the Adapter Clamp against this shoulder and fasten to 40
–60 in-lbs.
4. This tool was designed for, and can only be used with BAND-IT 1/2" and 3/4" wide Ultra-Lok
clamps. Do not attempt to use on any other type of clamp style. Only use 1/2" wide clamps when the optional 1/2" Shear Plate (BAND-IT
# M09387) has been installed in the head in place of the 3/4" Shear Plate.
Use only with BAND-IT 3/4" and 1/2" Ultra-Lok Free-End and Preformed Clamps
Tension Block Position Viewing Slot
(also lubrication syringe access)
Drill
Torque Dial
Speed Selector
Drill
M09587 or
M09687
Tool Head
Band Slot
Tool Body
Adapter
M06287
Adapter Collar
M08388
Forward
Reverse
Switch
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
P: 1-800-525-0758
F: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 3 of 14
Document # P07986 Rev. E
© Copyright
BAND-IT-IDEX, Inc. 2010
All rights reserved
Setup
Instructions
UL4000-B
UL4000-B220
Ultra-Lok
Tool
Orient Drill Clutch
Pin horizontally
NOTE: Alignment is critical for proper tool function.
Tension Screw
Drill Clutch
Note: Some components are not visible in this illustration.
Be careful to align the end of the Tension Screw with the slot in the end of the Drill Clutch, as shown above.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
P: 1-800-525-0758
F: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 4 of 14
Document # P07986 Rev. E
© Copyright
BAND-IT-IDEX, Inc. 2010
All rights reserved
Settings
UL4000-B
UL4000-B220
Ultra-Lok
Tool
Recommended Drill Torque Dial Settings:
Drill Model 37618-01 / GSR 18 VE-2LI
Clamp Size
Single Wrap
Double Wrap
½"
11-15
16-20
¾"
16-20
21-25
*Preformed
16-20 21-25
Set Speed Selector to “1”
(If a higher pullup force is desired, set speed selector to “2”. Band-It recommends hearing protection if this setting is used for an extended time.)
NOTE: These torque settings are suggested settings only; individual tools should be
adjusted for the clamping application. Inspect lock per instructions on page 9-11.
Important: Changing speed settings will alter tension output. Drill Switch should be depressed fully by the operator to attain correct, and consistent, tension when installing clamps. Tension output may vary from tool to tool, at the same setting, depending on condition and wear of internal components.
Caution: Improperly tightened clamps may result in dangerous assemblies, which could cause injuries or property damage.
Using correctly sized clamps (diameter) will, in most cases, eliminate the need to pull on clamp tail more than once. Tension Block moves approximately 5". On occasion, if needed, large size clamps can be installed by taking several bites (clamp tail feeds out through back of tool). Position of Tension Block, containing gripper, can be monitored through viewing holes just under cut-off handle. The tool features a built-in disengaging mechanism to prevent tension screw from jamming up. Excessive use of this feature will wear the Drill Clutch mechanism and/or Tension Screw out prematurely.
CAUTION!
This tool is designed to work mounted to the Bosch 37618-01 or Bosch GSR 18 VE-2LI cordless drill. Use of any other drills in place of this Bosch drill may result in unsatisfactory performance, hazards to the operator and/or the tool, or unsafe clamps. Disregard of this caution voids the warranty of the tool and releases BAND-IT of any and all liabilities arising from such misuses.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
P: 1-800-525-0758
F: 1-800-624-3925
Use of Alternate Drills www.BAND-IT-IDEX.com
Page 5 of 14
Document # P07986 Rev. E
© Copyright
BAND-IT-IDEX, Inc. 2010
All rights reserved
Parts List
UL4000-B
UL4000-B220
Ultra-Lok
Tool
Notes:
Apply Item 31 (Super Lube) to:
Item 4 (Cut-off Cam)
Item 3 (Cutter Knife) at contact point with item 1 (Tool Head)
Item 26 (Spring) before installation
Apply Item 32 (Grease) to:
Item 7 (Tension Screw) threads and at grooved end
Item 2 (Cutter Blade) counter-bore only, after item 14 (Bearing Tip) has been installed.
Item Part Number Qty Tighten the following:
Item 23 (#10-32 Screws)
to 60
– 70 in-lbs.
Item 22 (1/4-28 Screws)
to 90
– 110 in-lbs.
1
2
3
4
M00587
M09787
M08687
M08987
1
1
1
1
Description
Tool Head, Fin. UL
Cutter Blade, UL
Cutter Knife, UL
Cam, Cut-off, UL
Adjust Item 24 (Plunger) for positive detent action when item 6 (Handle) is actuated.
5
6
7
8
M09087
UL1219
M00987
M08887
1
1
1
1
Tension Block, Mach., UL
Handle Assembly:
Includes Handle, Handle Grip, and Pins
Tension Screw, Fin.
Gripper, UL
* Permatex P/N: 82325 or Equivalent
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
M01787
M09187
M02387
M00287
M01388
M05387
M06587
M02287
M04387
M07387
M07487
M07587
M05787
J67287
M06187
M02487
A33887
A53587
M01487
M08187
M08087
M07987
I16387*
C23199
M09887
M09387
1
1
1
1
Plate, Back, Cast/Fin.
Gripper Guide, UL
Plate, Release, cast/fin.
Roller, Cut-off, Fin.
2
1
1
1
1
1
1
2
2
4
Pin, .187 Dia X 1.50 Long, Fin.
Bearing Tip, Fin.
Ball, ¼” Diameter
Tip, Load Bearing, Fin.
Tripper Bracket, Cast/Fin.
Body, Left, Finished, UL
Body, Right, Finished, UL
Wear Plate, Fin.
Screw, Socket Head Cap, ¼ X 1”
Screw, Socket Head Cap, ¼ X ½”
Screw, Socket Head Cap, #10-
32 X 3/8”
4
2
1
2
1
4
4
2
Screw, Spring Plunger, ¼-20
Spring, Compression, .180 X .813 Long
Spring, Compression, .300 X 1.00 Long
Pin, Dowel, ¼ Dia X 1.50 Long
Washer, .128 ID X .238 OD
Rivet, Blind, .125 X .328 Long
Threaded Insert, #10-32
.07 Lubricant, Super Lube w/ Teflon (cc)
1
1
1
Lubricant, Moly, Syringe
Shear Plate, ¾”, UL
Shear Plate, UL, ½” (Optional)
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
P: 1-800-525-0758
F: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 6 of 14
Document # P07986 Rev. E
© Copyright
BAND-IT-IDEX, Inc. 2010
All rights reserved
Troubleshooting
6
30 2 Places
UL4000-B
UL4000-B220
Ultra-Lok
Tool
4
18
6
28
4 Places
23 4 Places
19
20
2 Places
Tension Block
Assembly
Head Unit
29
4 Places
22
4 Places
See page 6 for parts list
Trouble-Shooting
1. Lock slips down in buckle: Tighten blade mounting screws. If lock on clamp is still not adequate, reduce tension on tool by setting torque setting on the Drill Dial to a lower number.
2. Drill clutch releases prematurely: Make sure Tool is fully seated on Drill (per page 4). If problem persists, contact BAND-IT technical support.
Note: To mitigate Drill Clutch wear, do not over-use the Drill Clutch. When tensioning a clamp, let the
Drill Switch go as Tension Block nears its end of travel. Reverse drill and send Tension Block all the way forward for a second pull on the band.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
P: 1-800-525-0758
F: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 7 of 14
Document # P07986 Rev. E
© Copyright
BAND-IT-IDEX, Inc. 2010
All rights reserved
Assembly
Instructions
4 31
Lubricate both sides
11
25
Component under spring load when assembled
13
1
17
15 32
9
32
7 32
Tool Head Assembly
2 Places
21
14 32 2
Brush lubricant evenly on threads
2 Places
24
33
3
12
16
27
13
8
31
5
UL4000-B
UL4000-B220
Ultra-Lok
Tool
Tension Gripper Assembly
Component under spring load when assembled
26 31 2 Places
10
*
M09387 (Optional)
1/2" Shear Plate Insert can be substituted for
M09887
See page 6 for parts list
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
P: 1-800-525-0758
F: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 8 of 14
Document # P07986 Rev. E
© Copyright
BAND-IT-IDEX, Inc. 2010
All rights reserved
Clamp Application
Free-End Clamps
UL4000-B
UL4000-B220
Ultra-Lok
Tool
Warning: Always wear safety glasses when operating tool.
1. Break off an Ultra-Lok
Free-End tie from the roll. Slide the buckle onto band with indented arrows pointing in same direction and same side up. Slide buckle all the way onto band until it comes to a stop between the two buckle dimples at opposite end of tie.
4. Position the tie on the object you are clamping.
Pull the wrapped tie hand-tight. Slightly bend the tail up to keep the clamp in place
2. Wrap tie around object to be clamped.
Insert the tie through buckle once for single-wrap or twice for double-wrap.
Double-wrapped clamps have more than 3 times the loop-tensile strength.
DO NOT
FEATHER the drill’s TRIGGER when tensioning a clamp.
USE FULL SPEED
OF TOOL
3. If desired, you may preform a clamp in the same fashion as step 2, or use a preformed clamp in place of a Free-End
Push all the way forward to a solid stop
5. Actuate Drill until Tension Block is all the way forward against the tool body. Set Drill to clock-wise rotation. With cut-off handle down as shown, insert clamp tail into tool head slot.
Actuate Drill until Drill‟s built-in clutch disengages. If Tension Block comes near its end of travel, release actuator switch and reverse Drill to pull more on clamp tail.
Excessive use of disengaging Drill Clutch indicated by a loud ratcheting sound leads to premature wear of tension screw.
6. Do not force the tool against the clamp; it may result in a folded clamp tail.
7. Pull the cut-off handle forward to cut tail off and form a lock, then return handle to the down position. Reverse drill and feed clamp tail out of tool.
8. Tap down buckle shroud to complete clamp. Tool is ready for next clamp.
Correct position of tool while tensioning
Incorrect position of tool while tensioning
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
P: 1-800-525-0758
F: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 9 of 14
Document # P07986 Rev. E
© Copyright
BAND-IT-IDEX, Inc. 2010
All rights reserved
Clamp Application
Free-End Clamps
Inspect buckle on completed clamp and tap down buckle shroud.
Section View
Good Clamp
Bad Clamp
UL4000-B
UL4000-B220
Ultra-Lok
Tool
Important: Visually inspect lock formed in band as shown. If lock has slipped under the sheared surface of the buckle, remove clamp and install a new one at reduced tension by lowering the Drill Clutch torque setting.
SIDE VIEW
Completed Free-End
Clamp
Lock has slipped back under sheared buckle surface
Tap down buckle shroud to complete clamp
Lock sheared in center and formed inside shroud
FRONT VIEW
Completed Free-End Clamp
(Visually inspect lock)
Buckle Shroud
Shear Surface
Completed clamp should appear as shown.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
P: 1-800-525-0758
F: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 10 of 14
Document # P07986 Rev. E
© Copyright
BAND-IT-IDEX, Inc. 2010
All rights reserved
Clamp Application
Preformed Clamps
UL4000-B
UL4000-B220
Ultra-Lok
Tool
Place clamp in desired position on object to be clamped.
Follow steps 5 and 6 on page 9.
Inspect buckle on completed clamp and tap down buckle shroud as shown below.
Section View
Good Clamp
Lock sheared in center and formed inside shroud
Front View
Completed Clamp
(Visually inspect lock)
Shear Surface
Bad Clamp
Lock has slipped back under sheared buckle surface
Buckle Shroud
Important: Visually inspect lock formed in band as shown. If lock has slipped under the sheared surface of the buckle, remove clamp and install a new one at reduced tension by lowering the Drill Clutch torque setting.
Side View
Completed Clamp
Tap down buckle shroud to complete clamp
When applying clamps on soft, thick-walled hose, tension clamp then wait a full 30 seconds.
Clamps may be re-tensioned by squeezing the Drill Switch on the power unit a second time prior to forming the lock and cutting the excess clamp tail. This allows hose to “settle” under the band of the clamp. This hose material attribute is called Cold Flow. Finally, complete clamp by tapping down the buckle shroud as described above.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
P: 1-800-525-0758
F: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 11 of 14
Document # P07986 Rev. E
© Copyright
BAND-IT-IDEX, Inc. 2010
All rights reserved
Maintenance
1. Approximately every 500 clamps lubricate Tension Screw with molybdenum disulfide lubricant, or equivalent.
Make sure Tension Block is all the way forward against the Tool Head.
Remove cap from syringe and insert tip of syringe into slot on top of tool body.
Press the tip against the Tension Screw just behind the Tension Block and squeeze out approximately 1/2" long bead of lubricant. Remove Syringe, and actuate tool without a clamp a couple of times to spread lubricant evenly on tension screw.
To order more lubricant, specify BAND-IT #C23199
2. Every 500-1000 clamps, depending on torque setting, inspect and repack front bearing with same lubricant. Turn load bearing tip and small bearing tip over for a new bearing surface.
Bearing Detail
Tool
Head
Item 1
Small Bearing Tip
M05387
1/4" Ball
M06587
Load Bearing Tip
M02287
UL4000-B
UL4000-B220
Ultra-Lok
Tool
Tool
Body
Lubricating Syringe
Reorder #C23199
Access Hole to push out components (use paper clip)
Blade
M09787
Blade Cavity, must be packed with lubricant
Tension
Screw
M00987
3. To gain access to bearing components: remove blade Mounting Screws (2 places) and slide Blade free. Paper clip may be used to push bearing components out of Blade. Wipe lubricant from components. If ball or bearing tips appears heavily worn, replace with new one. Note: 1/4" ball is made from hard tungsten carbide material, do not replace with regular ball bearing.
(Smooth indention from ball in the bearing tips is normal).
To re-assemble bearing components: wipe blade cavity clean. Push small bearing tip into blade cavity. Apply lubricant to ball and push into Blade cavity and fill remaining space with lubricant. Push load bearing tip firmly into blade cavity, some lubricant will be squeezed out. Re-attach blade to Tool Head, making sure that load bearing tip extends into Tension Screw. While turning
Blade Mounting Screws into Blade, push on Blade rear-wards. Tighten screws to approximately 120 in-lbs.
4. When replacing worn Blade follow instructions above to properly reassemble bearing components.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
P: 1-800-525-0758
F: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 12 of 14
Blade Mounting
Screws
M05787
Document # P07986 Rev. E
© Copyright
BAND-IT-IDEX, Inc. 2010
All rights reserved
Maintenance
UL4000-B
UL4000-B220
Ultra-Lok
Tool
5. To replace Gripper: Make sure Tension Block is all the way forward against the tool head. Remove drill.
Remove tool adapter body. Remove one side of the tool body or the other, not both. Slide Gripper out sideways and replace with a new one. Re-attach Tool Body side. Caution: Do not push or move Tension Block while
Gripper is out of tool.
Tool Head
M00587
Move tension block all the way forward against the tool head
This tip must align with the drill clutch (M21790) on the drill. See page 4.
Gripper
M08887
Tension
Screw
M0098
7
6. To replace Tension Screw: Move Tension Block all the way back (away from Tool Head) using drill in tensioning mode (clock-wise). Remove Ultra-Lok
Tool from Drill. Remove the Tool Adapter from the Ultra-Lok
Tool. Remove Blade and load bearing tip from Tensioning Screw (see bearing detail). Remove one side of the
Tool Body or the other, not both. Grasp the smooth barrel on Tension Screw and pull all the way forward until
Tension Block is against the Tool Head. If Tension Screw is stuck, use a punch and tap the center of the screw from the back end of the tool. Turn Tension Screw out of Tension Block. Lubricate new Tension Screw with
Molybdenum Disulfide lubricant, or equivalent. Install new Tension Screw in reverse order; making sure that back end of Tension Screw extends well beyond the back end of the Tension Block. Push the assembly all the way back and extend the round portion of the Tension Screw through holes on the tripper bracket and back guide plate. Reinstall Tool Body side. Reinstall Blade and tighten the Blade Mounting Screws approximately 120 in-lbs.
Reattach Tool Adapter to Ultra-Lok
Tool. Reattach Tool to Drill and drive Tension Block all the way forward.
Note: Drills needing repair must be forwarded to an authorized „Bosch‟ repair center in your area. Be sure to remove BAND-IT drill clutch (M21790) from drill.
Bosch Drill is covered solely by the Bosch warranty as described in the Bosch literature. BAND-IT does not extend any warranty of any kind to the drill.
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
P: 1-800-525-0758
F: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 13 of 14
Document # P07986 Rev. E
© Copyright
BAND-IT-IDEX, Inc. 2010
All rights reserved
Blade Change
Optional 1/2" Tool
UL4000-B
UL4000-B220
Ultra-Lok
Tool
To change out the tool to the 1/2" version, the following steps should be followed.
*NOTE: Do not attempt to use 1/2" clamps with 3/4" head. (Shear Plate change-out: 3-5 minutes)
1. Prior to separation from power drill, back off Tension Block assembly 1/2" from head unit. See page 7.
2. Detach Tension Body from the Drill by loosening the single tensioning bolt on the aluminum collar and separating the two sections.
3. Remove the Blade from head by removing the two Cap Screws (M05787) from the top of the Head. It is not necessary to remove entire head from tool in order to remove blade. (Figure 1) Remove the 3/4" shear plate from the blade.
4. Align the 1/2" Shear Plate (M09387) with the Blade (M09787) so that the guide is facing up. Incorrect placement will not allow bands to be inserted into the Tool. (Figure 1)
Note: To convert Tool back to 3/4", replace 1/2" Shear Plate with 3/4" Shear Plate (M09887) and follow same instructions. Be sure to retain unused Shear Plate for later use.
5. Attach the Blade and 1/2" Shear Plate onto Head using the two previously removed Cap Screws. These Cap Screws must be tight to assure proper cut-off of clamp tails.
6. Re-attach Drill to Tension Body making sure the Drill and Tension Body are properly aligned, and tighten the single
Blade Cap Screw located on the Adapter Collar.
7. These tools are not designed to work with traditional band and buckle designs. BAND-IT Ultra-Lok
clamps must be used.
Blade Cap Screw
(M05787) Qty. 2
1/4" Ball (M06587)
Bearing Tip (M05387) Blade (M09787)
Optional 1/2" Shear
Plate (M09387)
Orient as shown
Blade (M09787)
Figure 1 Figure 2
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
P: 1-800-525-0758
F: 1-800-624-3925
www.BAND-IT-IDEX.com
Page 14 of 14
Document # P07986 Rev. E
© Copyright
BAND-IT-IDEX, Inc. 2010
All rights reserved
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement