Daikin UK Price List 2014 - Climate Controls and Spares

Daikin UK Price List 2014 - Climate Controls and Spares
your comfort. our world.
Daikin UK Price List 2014
Residential, Commercial and Industrial
Climate Controls and Spares UK Ltd
“Daikin UK Added Value Reseller”
A Family owned and run Independent Distributor
specialising in Refrigeration, Heating and Cooling
Equipment offering a Year Round Climate
Solution. Our product Range encompasses
Market Leading Brands and a large range of
spares and ancillaries that you would expect from
a quality wholesale outlet.
Climate Controls and Spares UK Ltd are Strategically Located
just off the A38 in Ivybridge Devon supplying their customers
through their Trade Counter or on a Next Day Service Nationally
throughout the UK and Europe.
Climate Controls and Spares Ltd
Unit 3 Beech Road Business Park
Cadleigh, Ivybridge, Devon, PL21 9HN
Telephone 01752 894777
Conditions
Capacity conditions
Seasonal efficiency
Unit cooling and heating capacities shown within this price list
are based on the following conditions:
Systems of up to 12kW must now show Seasonal Efficiency
Ratings instead of Nominal Efficiency Ratings. These ratings
(SEER for cooling, SCOP for heating) represent how effective
a system is throughout the year, and are in accordance with
EN14825. For more information on Seasonal Efficiency,
visit www.daikin.co.uk/seasonal-efficiency
Nominal cooling
Ambient = 35°C
Internal = 27°C db 19°C wb
Nominal heating
Ambient = 7°C db 6°C wb
Internal = 20°C db
UK cooling
Ambient = 30°C
Internal = 22°C db 16°C wb
For Daikin UK, this means all our Split and Sky Air products
up to 12kW display SEER and SCOP data along with Energy Label
information and Annual Energy Consumption of the system.
The AEC is based upon 500 hours use per year.
Nominal efficiency
This measure of efficiency is calculated by dividing the capacity
output of a unit by the power required to deliver it. For cooling,
this is expressed as EER, for heating as COP.
Nominal efficiencies are used for systems above 12kW. It is not
possible to compare nominal and Seasonal Efficiency ratings.
Cooling mode
Unless otherwise indicated, all units within this price list are
air-cooled.
UK. prefix accessories
All accessory items shown in this price list with the prefix ‘UK.’
are not manufactured by Daikin.
Contents
New for 2014
2
Commercial Heating
91
Split, Sky Air Heat Pumps5
Refrigeration95
VRV45
Applied99
Ventilation89
Miscellaneous111
Discount Rating
Please insert your discounts here and then refer to the colour tabs on the edge of each page for reference.
Split, Sky Air Heat Pumps
VRV
Ventilation
MY DISCOUNT
MY DISCOUNT
MY DISCOUNT
%
%
%
Commercial Heating
Refrigeration
Applied
MY DISCOUNT
MY DISCOUNT
MY DISCOUNT
%
%
%
Price List 2014
1
New for 2014
design
efficiency
360° EFFICIENCY
Our new VRV IV heat recovery system sets pioneering
standards in all-round climate control efficiency.
NEW
installation
efficiency
M
FRO MN
U
AU T014
2
VRV IV
FAST
design
QUICK
installation
+
operational
efficiency
HEAT
recovery
•Multiple new design options to meet the
projects priorities
• Efficiency • Comfort • Footprint •
•Unrivalled flexibility to adapt the system
layout as the building use changes
•Reduce installation time by over 30%
•Setup condensers in seconds with the
new configurator
MORE
free heat
MAX
comfort
•The biggest leap forward in real efficiency
since the inverter compressor
•An additional 15% Increase in
Heat Recovery efficiency
•Exceptional prevention against
cold draughts
•Definable settings to provide control over
off coil temperatures
Coming soon
BRANCH SELECTOR BOXES
Unique range of single and multi BS boxes for flexible and fast design.
BS1Q10,16,25A
BS4Q14A
BS6,8Q14A
NEW
M
FRO MN
U
AU T014
2
BS10,12Q14A
BS16Q14A
SINGLE PORT
MULTI PORT: 4 – 6 – 8 – 10 – 12 – 16
• Compact & light to install
• No limit on unused ports allowing phased installation
• No drain piping needed
• Faster installation thanks to a reduced number of brazing points and wiring
• Ideal for remote rooms
• Up to 140 class indoor units connectable to one BS box
• Technical cooling function
• Less inspection ports needed
• Connect up to 250 class unit (28kW)
• Up to 16 kW capacity available per port
• Allows multi tenant applications
• Connect up to 250 class unit (28kW) by combining 2 ports
Coming soon
2
Residential, Commercial and Industrial
WALL MOUNTED UNITS – EMURA
N
W L AR O L
T
CO N A P P
V IA
• Complete re-design of indoor units – smart, elegant and contemporary
NEW
• Range extension: now 2.0kW to 5.0kW
• Highest Seasonal Efficiencies – up-to A+++
• Intelligent features to save energy & enhance comfort
• WiFi connection for connection anywhere via smart phone or tablet
Page 9
SPLIT OUTDOOR UNITS – RXS
NEW
• Upgraded to ensure compliance with ErP directive
• T he RXS range has been upgraded
• 2kW to 6kW will be L series
• 7.1kW series will be F8 series
• T he RX series larger capacity also upgraded
• 60 and 71 has become GVB series
• T he changes to both ranges are to improve the SEER
and SCOP of paired split units
Page 10 / 15 / 18 / 19 / 23 / 28 / 31
REFRIGERATION – ZEAS
NEW
• An expanded range of medium and low temperature refrigeration solutions
• Now available as Multi for larger capacity installations
• Multi Zeas combines 2 modules to deliver:
• LREQ30BY1: 67.8kW
• LREQ40BY1: 75.8kW
Page 97
APPLIED – EWAD-TZ CHILLER RANGE
• Offers class-leading energy efficiencies (EER up to 3.6; ESEER up to 5.7,
tested to EN14511 this equates to an incredible ESEER gross value of 6.0)
• L ower running costs and carbon emissions by up to 20% compared with
traditional chillers, thanks to advanced inverter screw compressor technology
•
Daikin offer this new range in 3 efficiency versions
• Silver – ESEER up to 4.8 with on / off fan motors
• Gold – ESEER up to 5.2 with AC Inverter fan motors
• Platinum – ESEER up to 5.7 with brushless fan motors
NEW
Page 100
NEW
BLDC (BRUSHLESS DC) – DAIKIN CHILLED WATER FAN COIL UNITS
• Slashes energy consumption by up to 70%, compared with models
fitted with AC motors
• T his super-efficient range can also maintain enhanced comfort levels
with minor variations in air temperature and relative humidity
• Floor standing units FWZ-A, Flexi units with cabinet FWR-A,
Flexi units without cabinet FWS-A and Medium ESP
(External Static Pressure) ducted units FWP-A
Page 105 - 107
Price List 2014
3
The Gym, Broad Street Mall, Reading
SPLIT, SKY AIR HEAT PUMPS
Split, Sky Air Heat Pumps
Energy Related Products Directive Update
6
Enhanced Capital Allowance (ECA) Scheme
6
Introduction
7
Pair Applications
9
Wall Mounted Split Systems
9
Floor Standing Split Systems
14
Flexi Type Split Systems
18
Ceiling Mounted Split Systems
19
Cassette Split Systems
23
Under Ceiling Cassette Split Systems
30
Ducted Split Systems
31
Multi Applications
36
Multi Split Systems
36
Twin, Triple, Double Twin Systems
38
Scotland
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
SPLIT, SKY AIR HEAT PUMPS
Energy Related Products directive update
The ErP Directive has been updated as of January
1st 2014 to ensure products up-to 12kW are even
more efficient.
Minimum requirements
2013
SEER < 6kW
The original and the new minimum standards can be seen in
the table. These standards are for cooling (SEER) and heating
(SCOP) and are based on Seasonal Efficiency rather than nominal
efficiency. This is a more accurate way of looking at efficiency as
it takes into account seasonal temperature variations, part load
performance and power consumed on stand-by.
4.6
3.6
SEER ≥ 6kW
The ErP originally came into force January 1st 2013 and
implemented minimum energy efficiency standards for products
up to 12kW, which covers most of Daikin’s split & sky air ranges.
2014
SCOP
4.3
3.4
Energy efficiency class
The minimum standards are enforced through Energy Labelling
– with the label clearly displaying the SEER and SCOP along with
relevant Energy Label.
All Daikin split and Sky products clearly list the SEER, SCOP and
Energy Label data. Many of these products achieve A++ or A+++
Energy Labels, making them some of the most efficient available.
Multi split and twin, triple systems up to 12kW must also have
energy labels. It is possible to obtain Energy Label data for multi,
twin and triple systems up to 12kW at www.daikineurope.com/
energylabel
3.8
SEER
SCOP
SEER ≥ 8.50
SCOP ≥ 5.10
6.10 ≤ SEER < 8.50
4.60 ≤ SCOOP < 5.10
5.60 ≤ SEER < 6.10
4.00 ≤ SCOOP < 4.60
5.10 ≤ SEER < 5.60
3.40 ≤ SCOOP < 4.00
4.60 ≤ SEER < 5.10
3.10 ≤ SCOOP < 3.40
4.10 ≤ SEER < 4.60
2.80 ≤ SCOOP < 3.10
3.60 ≤ SEER < 4.10
2.50 ≤ SCOOP < 2.80
Enhanced Capital Allowance (ECA) scheme
Daikin energy-efficient technology has achieved further recognition. You’ll now find more of our air
conditioning units on the Energy Technology List (ETL) – the definitive list of products that qualify for
Enhanced Capital Allowance (ECA).
Our products have now been confirmed as among the most
efficient in the market.
You can now be confident of offering your customers Daikin
equipment that is ECA-qualified. This will enable you to compete
for jobs wherever this is a specific requirement of the end-user.
How to check eligibility for ECA tax relief:
The ECA scheme is open to all businesses that pay Corporation
Tax or Income Tax.
Confirming ECA product eligibility is easy. The Carbon Trust
publishes the ETL on behalf of the Government. You or your
customers can find this at www.etl.decc.gov.uk/etl/site.html
What’s changed – and why?
Technological progress and changes to legislation have recently led to efficiency performance thresholds being raised.
OLD THRESHOLDS
Change
EER
COP
SEER
SCOP
<12kW
Split
3.21
3.61
6.10
4.00
>12kW
Split
3.21
3.61
3.21
3.71
+0.1 (COP)
>12kW
VRV
3.30
3.70
3.40
3.80
+0.1 (COP & EER)
As a result, older products from a number of
manufacturers became ineligible for ECA and
have now been removed from the ETL.
6
NEW THRESHOLDS
Residential, Commercial and Industrial
Move to seasonal
However, the Daikin additions to the list now mean we currently offer a wider choice
of ECA-eligible air conditioning products than any other manufacturer. And even
more of our units are expected to appear on the ETL early in 2014.
SPLIT, SKY AIR HEAT PUMPS
Sky Air – The range that has all the right answers
The three SkyAir ranges from Daikin now ensure you can satisfy the needs of every customer
– and help you WIN more projects. Whether your customers want to maximise energy-efficiency,
optimise their running costs, or simply keep the up-front cost to a minimum, you will always have the
right answer ready for them with SkyAir.
Compare the three ranges
and get to know the choices:
SkyAir gives you three reasons to win with Daikin
Seasonal Smart
The top-of-range PREMIUM option
Offering all the same features as Seasonal Classic, plus…
• I ndustry-leading energy efficiency
• Longer
pipe runs – up to 75m
Siesta
The ECONOMY option
• E DP setting for comms rooms
• Low purchase price for reduced upfront cost
• O
ptional slim under-ceiling cassette: for comfortable
all-round airflow in buildings with solid ceilings or
limited-depth ceiling voids
• Compatible with Daikin Siesta SkyAir cassette,
ceiling-suspended and ducted indoor units
• Allows pipe runs up to 50m
• Ideal for new installations
• G ood operating range for most UK
climate conditions
• Wide operating range able to cope efficiently with
unusual temperature extremes
• E U energy ratings: Up to A++ for both heating
and cooling modes
• L isted on the Energy Technology List (ETL)
• EU energy ratings: Up to B for cooling and
A for heating
Add-on options
extra efficiency for your customers
Make sure you offer your customers the benefits of Daikin
add-on options – especially with Seasonal Smart. These can
help cut future operating costs even further. Options include:
Self-Cleaning Cassette
Cassette Presence Sensor
RTDs
To see how extra energy-saving options can
deliver significant savings for your customers,
try the SkyAir Selection tool.
Visit: daikin.co.uk/win
Seasonal Classic
The all-rounder STANDARD option
• Suitable for triple and twin applications
• Connection to up to four indoor units
• Compatible with existing R22 system pipework
• Compatible with most Daikin SkyAir indoor units
including wall, floor and large-ducted options
• Allows pipe runs up to 50m
• Good operating range for most UK climate conditions
• EU energy ratings: Up to A++ for cooling and A+ for heating
Price List 2014
7
SPLIT, SKY AIR HEAT PUMPS
SPLIT, SKY AIR HEAT PUMPS
Wall Mounted – Inverter
Emura
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
Matt Crystal White
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
FTXG25LW
FTXG35LW
FTXG50LW
FTXG20LS
FTXG25LS
FTXG35LS
FTXG50LS
2.25
1.84
2.00
2.50
A+++
2.30
8.52
94
A++
2.10
4.60
639
4.59 / 5
A/A
250
8.8 / 4.4
2.35
1.88
2.50
3.40
A+++
2.40
8.50
99
A++
2.70
4.60
821
4.59 / 4.42
A/A
261
8.8 / 4.4
3.42
2.51
3.50
4.00
A++
3.50
7.00
175
A++
3.00
4.60
913
3.97 / 4.06
A/A
441
11 / 4.8
4.69
3.09
5.00
5.80
A++
4.80
6.70
251
A+
4.60
4.24
1519
3.53 / 3.65
A/A
680
11.3 / 6.8
2.25
1.84
2.00
2.50
A+++
2.30
8.52
94
A++
2.10
4.60
639
4.59 / 5
A/A
250
8.8 / 4.4
2.35
1.88
2.50
3.40
A+++
2.40
8.50
99
A++
2.70
4.60
821
4.59 / 4.42
A/A
261
8.8 / 4.4
3.42
2.51
3.50
4.00
A++
3.50
7.00
175
A++
3.00
4.60
913
3.97 / 4.06
A/A
441
11 / 4.8
4.69
3.09
5.00
5.80
A++
4.80
6.70
251
A+
4.60
4.24
1519
3.53 / 3.65
A/A
680
11.3 / 6.8
12
38 / 25
54
12
45 / 26
59
12
45 / 35
60
RXG25L
RXG35L
303
998
212
12
38 / 25
54
RXG20L
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
Silver
FTXG20LW
2.70
2.8
16
1/4 / 3/8
20
15
10
1.05
46
61
£262.00
£478.00
£740.00
303
998
212
12
38 / 25
54
12
45 / 26
59
RXG25L
RXG35L
550 x 765 x 285
35
1ph
2.80
4.80
4.4
5.5
16
16
3+E / 1.5
1/4 / 3/8
1/4 / 3/8
20
20
15
15
10
10
20
1.05
1.05
46
48
61
63
£276.00
£504.00
£780.00
£310.00
£585.00
£895.00
12
45 / 35
60
12
38 / 25
54
RXG50L
RXG20L
735 x 825 x 300
48
6.20
7.4
20
3+E / 2.5
1/4 / 1/2
30
20
10
2.70
2.8
16
1/4 / 3/8
20
15
10
1.6
48
63
1.05
46
61
£473.00
£936.00
£1,409.00
£313.00
£478.00
£791.00
Accessories:
550 x 765 x 285
35
1ph
2.80
4.80
4.4
5.5
16
16
3+E / 1.5
1/4 / 3/8
1/4 / 3/8
20
20
15
15
10
10
20
1.05
1.05
46
48
61
63
£329.00
£504.00
£833.00
RXG50L
735 x 825 x 300
48
6.20
7.4
20
3+E / 2.5
1/4 / 1/2
30
20
10
1.6
48
63
£369.00
£585.00
£954.00
£565.00
£936.00
£1,501.00
Notes:
Accessory Ref
Description
Trade Price
BRC944
BRCW901A03
BRCW901A08
BRP069A41
KRP413A1S
KRP928A2S
KLIC-DD
RTD-RA
UK.CWB90-2
UK.DT1
UK.CGS
UK.CGM
Optional Wired Remote controller
3m connection cable for BRC944
8m connection cable for BRC944
Adaptor for connection to on-line controller
Adaptor PCB for remote on/off control - constant/pulse contact
Adaptor PCB for interface to Daikin centralised control systems
KNX interface for Split type systems
Adaptor PCB for Modbus connection and/or extended system functions
Condensing unit bracket - up to size 71
Condensate drip tray for use with UK.CWB90-2
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£64.00
£17.00
£22.00
£40.00
£75.00
£132.00
£164.00
£151.00
£37.00
£56.00
£214.00
£296.00
i)All fan coil units standard with auto restart
after power failure
ii)All fan coils supplied as standard with
infrared remote controller
iii)Wired controller, KLIC-DI and RTD-RA
options cannot be combined
iv)Minimum ambient operating
temperatures:
RXG
Cooling
Heating
-10°C
-15°C
Features:
• Designed in Europe, perfect for UK climates, Daikin Emura creates the optimum comfort zone all year round
• It represents a perfect marriage of style and substance, of form and function, of intelligent heating and efficient cooling
• Stylish, low-profile design
•Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming.
Up to 4 actions per day possible
• Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops
• Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room
• 2-area intelligent eye: air flow is sent to a zone other than where the occupants are located at that moment
• Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins
• Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting
• Fan speed: 5 fan speeds can be selected, high to super low
• Suitable for multi model applications
• Re-use of existing R22 and R407C piping possible
N
W L AR O L
T
CO N A P P
V IA
Price List 2014
9
SPLIT, SKY AIR HEAT PUMPS
Wall Mounted – Inverter
FTXS-K/G
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
FTXS-K series
FTXS-G series
FTXS20K
FTXS25K
FTXS35K
FTXS42K
FTXS50K
FTXS60G
FTXS71G
1.95
1.65
2.00
2.50
A++
2.00
7.40
95
A++
2.30
4.77
675
4.65 / 4.72
A/A
215
8.8 / 4.7
289
780
215
8
40 / 24
58
2.44
1.82
2.50
3.40
A++
2.50
7.90
111
A++
2.50
4.78
732
4.39 / 4.67
A/A
285
9.1 / 5
289
780
215
8
41 / 25
58
3.42
2.56
3.50
4.00
A++
3.50
7.47
164
A++
3.60
4.85
1039
4.07 / 4.76
A/A
430
11.2 / 5.8
298
900
215
11
45 / 29
59
4.11
2.85
4.20
5.40
A++
4.20
6.80
216
A+
4.00
4.20
1334
3.56 / 4.12
A/A
590
11.2 / 7
298
900
215
11
45 / 33
59
4.56
3.14
5.00
5.80
A++
5.00
6.80
257
A+
4.60
4.20
1535
3.55 / 4
A/A
705
11.9 / 7.4
298
900
215
11
46 / 34
60
5.86
3.87
6.00
7.00
A
6.00
5.58
376
A
4.80
3.89
1728
3.02 / 3.43
B/B
995
16 / 11.3
290
1050
250
12
45 / 36
61
6.94
4.65
7.10
8.20
A
7.10
5.23
475
A
6.50
3.50
2593
3.02 / 3.22
B/C
1175
17.2 / 11.5
290
1050
250
12
46 / 37
62
RXS20L
RXS25L
RXS35L
RXS42L
RXS50L
RXS60L
550 x 765 x 285
34
1.0
46
59
34
1ph
3.10
3.3
10
3+E / 1.5
1/4 / 3/8
20
15
10
20
1.0
46
59
£154.00
£436.00
£590.00
£165.00
£476.00
£641.00
2.30
2.8
10
1/4 / 3/8
20
15
10
550 x 765 x 285
735 x 825 x 300
34
39
4.10
4.3
10
5.70
6.6
20
1/4 / 3/8
20
15
10
1/4 / 3/8
20
15
10
1.2
48
61
1.3
48
61
47
1ph
6.30
6.8
20
3+E / 2.5
1/4 / 1/2
30
20
10
20
1.7
48
62
£189.00
£552.00
£741.00
£212.00
£623.00
£835.00
£294.00
£694.00
£988.00
Accessories:
RXS71F8
48
770 x 900 x 320
71
8.80
9.4
20
10.49
11.7
20
1/4 / 1/2
30
20
10
1/4 / 5/8
30
20
10
1.5
49
62
2.3
52
65
£300.00
£740.00
£1,040.00
£400.00
£1,013.00
£1,413.00
Notes:
Accessory Ref
Description
Trade Price
KRP980A1
BRC944
BRCW901A03
BRCW901A08
KRP928A2S
KLIC-DD
RTD-RA
UK.CWB90-2
UK.DT1
UK.CGS
UK.CGM
Adaptor for FTXS20K & 25K for ALL control options
Optional Wired Remote controller
3m connection cable for BRC944
8m connection cable for BRC944
Adaptor PCB for interface to Daikin centralised control systems
KNX interface for Split type systems
Adaptor PCB for Modbus connection and/or extended system functions
Condensing unit bracket - up to size 71
Condensate drip tray for use with UK.CWB90-2
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£68.00
£64.00
£17.00
£22.00
£132.00
£164.00
£151.00
£37.00
£56.00
£214.00
£296.00
i)All fan coil units standard with auto restart
after power failure
ii)All fan coils supplied as standard with
infrared remote controller
iii)Wired controller, KLIC-DI and RTD-RA
options cannot be combined
iv)FTXS-K and FTXS-G have different
style casing
v)Minimum ambient operating
temperatures:
RXS
Cooling
Heating
-10°C
-15°C
Features:
•
•
•
•
•
•
•
•
•
Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible
Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops
Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room
2-area intelligent eye: (35~50 K class) air flow is sent to a zone other than where the occupants are located at that moment
Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins
Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting
Fan speed: 5 fan speeds can be selected, high to super low
Suitable for multi model applications
Re-use of existing R22 and R407C piping possible
10
Residential, Commercial and Industrial
SPLIT, SKY AIR HEAT PUMPS
Wall Mounted – Low Inverter
FTX-J/G
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
FTX20JV
FTX25JV
FTX35JV
FTX50GV
FTX60GV
FTX71GV
1.95
1.60
2.00
2.50
A+
2.00
5.63
124
A++
2.20
4.67
660
3.64 / 4.24
A/A
275
9.1 / 5.9
283
770
198
7
39 / 25
55
2.44
1.78
2.50
2.80
A+
2.50
5.63
155
A+
2.40
4.50
747
3.42 / 4.06
A/A
365
9.2 / 6
283
770
198
7
40 / 26
55
3.07
2.11
3.30
3.50
A+
3.30
5.66
204
A+
2.80
4.14
945
3.37 / 3.76
A/A
490
9.3 / 6.1
283
770
198
7
41 / 27
58
4.89
3.32
5.00
5.80
A+
5.00
5.63
311
A+
4.60
4.08
1578
3.23 / 3.63
A/A
775
14.7 / 10.3
290
1050
238
12
43 / 34
59
5.86
3.88
6.00
7.00
A
6.00
5.37
391
A
4.80
3.88
1730
3.02 / 3.43
B/B
995
16.2 / 11.4
290
1050
238
12
45 / 36
60
6.94
4.46
7.10
8.20
B
7.10
4.97
500
A
6.20
3.81
2276
3.02 / 3.22
B/C
1175
17.4 / 11.6
290
1050
238
12
46 / 37
63
RX25JV
RX35JV
RX50GV
RX60GVB
RX20JV
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
0.7
46
60
550 x 658 x 275
28
1ph
3.49
3.7
16
3+E / 1.5
1/4 / 3/8
15
12
10
20.0
0.7
46
60
£123.00
£364.00
£487.00
£136.00
£389.00
£525.00
28
2.49
2.7
16
1/4 / 3/8
15
12
10
RX71GVB
735 x 825 x 300
30
48
4.99
5.0
16
6.75
7.4
20
1/4 / 3/8
15
12
10
1/4 / 1/2
30
20
10
1.0
48
62
1.5
47
61
47
1ph
8.62
9.4
20
3+E / 2.5
1/4 / 1/2
30
20
10
20.0
1.5
49
63
£154.00
£453.00
£607.00
£250.00
£590.00
£840.00
£255.00
£629.00
£884.00
Accessories:
770 x 900 x 320
71
10.40
11.7
20
1/4 / 5/8
30
20
10
2.3
52
65
£341.00
£904.00
£1,245.00
Notes:
Accessory Ref
Description
Trade Price
UK.CWB90-2
UK.DT1
UK.CGS
UK.CGM
Condensing unit bracket - up to size 71
Condensate drip tray for use with UK.CWB90-2
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£37.00
£56.00
£214.00
£296.00
i)All fan coils supplied as standard with
infrared remote controller
ii)All fan coil units standard with auto restart
after power failure
iii)Minimum ambient operating
temperatures:
RX-JV
RX-GVB
Cooling
Heating
+10°C
-10°C
-15°C
-15°C
Features:
•
•
•
•
•
•
•
Wireless remote controller with daily timer
Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops
Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room
Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting
Fan speed: 5 fan speeds can be selected, high to super low
Suitable for multi model applications
Re-use of existing R22 and R407C piping possible
Price List 2014
11
SPLIT, SKY AIR HEAT PUMPS
Wall Mounted –
Seasonal Smart Inverter FAQ-C / RZQG
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
3 Phase
FAQ71C
FAQ100C
FAQ71C
FAQ100C
7.76
5.32
6.80
7.50
A++
6.80
6.51
365
A+
6.33
4.02
2204
3.4 / 3.7
A/A
1000
18 / 14
290
1050
238
13
45 / 40
58
10.80
7.44
9.50
10.80
A++
9.50
6.11
544
A+
10.20
4.01
3561
3.62 / 3.61
A/A
1315
26 / 19
340
1200
240
17
49 / 41
62
7.76
5.32
6.80
7.50
A++
6.80
6.51
365
A+
6.33
4.02
2204
3.4 / 3.7
A/A
1000
18 / 14
290
1050
238
13
45 / 40
58
10.80
7.44
9.50
10.80
A++
9.50
6.11
544
A+
10.20
4.01
3561
3.62 / 3.61
A/A
1315
26 / 19
340
1200
240
17
49 / 41
62
RZQG71L8V1
RZQG100L8V1
RZQG71L8Y1
RZQG100L8Y1
990 x 940 x 320
78
1ph
8.17
4
20
1430 x 940 x 320
102
990 x 940 x 320
80
1430 x 940 x 320
101
10.75
4
32
3.07
4
16
3ph
4.04
4
20
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
50
75
30
30
30
30
Refer to Installation Manual
2.9
4.0
48
50
64
66
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
50
75
30
30
30
30
Refer to Installation Manual
2.9
4.0
48
50
64
66
£799.00
£1,191.00
£1,990.00
£799.00
£1,227.00
£2,026.00
£863.00
£1,514.00
£2,377.00
Accessories:
Notes:
Accessory Ref
Description
Trade Price
BRC7EB518
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
UK.CWB90-2
UK.CWB140-2
UK.DT1
UK.DT2
UK.CGM
UK.CGL
Wireless remote controller
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Condensing unit bracket - up to size 71
Condensing unit bracket - sizes 100 to 140
Condensate drip tray for use with UK.CWB90-2
Condensate drip tray for use with UK.CWB140-2
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
£152.00
£92.00
£190.00
£235.00
£251.00
£185.00
£47.00
£89.00
£93.00
£37.00
£46.00
£56.00
£59.00
£296.00
£354.00
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)BRC7EB518 Trade price will be reduced by
£76.00 if ordered instead of the BRC1E52A
iii)All fan coil units standard with auto restart
after power failure
iv)Minimum ambient operating
temperatures:
RZQG
RZQSG
Features:
•
•
•
•
•
•
•
•
•
Fan speed: 3 fan speeds available on all capacities
Automatic airflow volume control sets fan speed based on difference between set and room temperatures
Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature
Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)
Selectable evaporating & condensing temperature for greater operating efficiency and application flexibility (Seasonal Smart)
DIII net compatibility as standard
Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology
Re-use of existing R22 and R407C piping possible. (See R22 Replacement leaflet)
Suitable for Twin, Triple and Double Twin applications
12
£863.00
£1,584.00
£2,447.00
Residential, Commercial and Industrial
Cooling
Heating
-15°C
-15°C
-20°C
-15°C
SPLIT, SKY AIR HEAT PUMPS
Wall Mounted –
Seasonal Classic Inverter FAQ-C / RZQSG
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
3 Phase
FAQ71C
FAQ100C
FAQ100C
7.28
4.99
6.80
7.50
A+
6.80
6.05
393
A+
6.00
3.90
2155
3.21 / 3.61
A/A
1059
18 / 14
290
1050
238
13
45 / 40
58
10.80
7.44
9.50
10.80
A+
9.50
5.61
592
A+
6.81
4.01
2377
3.01 / 3.41
B/B
1580
26 / 19
340
1200
240
17
49 / 41
62
10.80
7.44
9.50
10.80
A+
9.50
5.61
592
A+
6.81
4.01
2377
3.01 / 3.41
B/B
1580
26 / 19
340
1200
240
17
49 / 41
62
RZQSG71L3V1
RZQSG100L8V1
RZQSG100L8Y1
770 x 900 x 320
67
990 x 940 x 320
81
2.75
49
65
2.9
53
69
990 x 940 x 320
82
3ph
4.86
4
20
3+E / 1.5
3/8 / 5/8
50
30
30
Refer to Installation Manual
2.9
53
69
£799.00
£881.00
£1,680.00
£863.00
£1,220.00
£2,083.00
£863.00
£1,257.00
£2,120.00
1ph
A
A
A
8.66
4
20
12.91
4
32
3+E / 1.5
inches
m
m
m
g/m
kg
dBA
dBA
3/8 / 5/8
50
30
30
3/8 / 5/8
50
30
30
Refer to Installation Manual
Price List 2014
13
SPLIT, SKY AIR HEAT PUMPS
Floor Mounted – Inverter
Nexura
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
FVXG25K
FVXG35K
FVXG50K
2.44
1.93
2.50
3.40
A++
2.50
6.53
134
A++
2.80
4.65
842
TBC / TBC
TBC / TBC
TBC
8.9 / 5.3
600
950
215
22
38 / 26
52
3.42
2.37
3.50
4.50
A++
3.50
6.48
189
A+
3.10
4.00
1087
TBC / TBC
TBC / TBC
TBC
9.1 / 5.3
600
950
215
22
39 / 27
52
4.81
3.17
5.00
5.80
A+
5.00
5.41
324
A+
4.60
4.18
1543
TBC / TBC
TBC / TBC
TBC
10.6 / 7.3
600
950
215
22
44 / 36
58
RXG25L
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
RXG35L
RXG50L
550 x 765 x 300
34
735 x 825 x 315
48
34
1ph
4.6*
5.5
10
2.9*
4.4
10
6.7*
7.4
20
3+E / 2.5
1/4 / 1/2
30
20
10
3+E / 1.5
inches
m
m
m
g/m
kg
dBA
dBA
1/4 / 3/8
20
15
10
1.05
46
61
1/4 / 3/8
20
15
10
20
1.05
48
63
£631.00
£504.00
£1,135.00
£679.00
£585.00
£1,264.00
Accessories:
1.60
48
63
£744.00
£936.00
£1,680.00
Notes:
Accessory Ref
Description
Trade Price
i)Data marked * is provisional
BRC944
BRCW901A03
BRCW901A08
KRP413A1S
KRP928A2S
KLIC-DD
RTD-RA
BKS028
UK.CWB90-2
UK.DT1
UK.CGS
UK.CGM
Optional Wired Remote controller
3m connection cable for BRC944
8m connection cable for BRC944
Adaptor PCB for remote on/off control - constant/pulse contact
Adaptor PCB for interface to Daikin centralised control systems
KNX interface for Split type systems
Adaptor PCB for Modbus connection and/or extended system functions
Leg for floor-standing installation
Condensing unit bracket - up to size 71
Condensate drip tray for use with UK.CWB90-2
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£64.00
£17.00
£22.00
£75.00
£132.00
£164.00
£151.00
£393.00
£37.00
£56.00
£214.00
£296.00
ii)All fan coils supplied as standard with
infrared remote controller
iii)All fan coil units standard with auto restart
after power failure
iv)Wired controller, KLIC-DI and RTD-RA
options cannot be combined
v)Minimum ambient operating
temperatures:
RXG
Cooling
Heating
-10°C
-15°C
Features:
• Radiant Heat panel provides radiator-like warming at the touch of a button
• Energy efficient units: full range A class energy labels
• Wireless remote controller provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 4 actions per day
• Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room
• Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting
• Extremely quiet in operation: down to 19dBA sound pressure level
•Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops,
so you can sleep more comfortably
•Vertical auto swing system automatically makes the louvers move up and down, creating an even distribution of air through the room to
ensure a harmonized temperature
•Flexible installation: Can be installed against a wall, recessed or standing on the floor (installation leg required, see accessories list).
Ideal for installation beneath a window
• Suitable for multi model applications
• Re-use of existing R22 and R407 piping possible
14
Residential, Commercial and Industrial
SPLIT, SKY AIR HEAT PUMPS
Floor Mounted – Inverter
FVXS
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
High
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
FVXS25F
FVXS35F
FVXS50F
2.44
1.87
2.50
3.40
A+
2.50
5.74
152
A+
2.60
4.56
798
4.39 / 4.42
A/A
285
8.2 / 4.8
600
700
210
14
38 / 26
52
3.42
2.34
3.50
4.50
A+
3.50
5.60
219
A
2.90
3.93
1033
3.43 / 3.78
A/A
510
8.5 / 4.9
600
700
210
14
39 / 27
52
4.89
3.21
5.00
5.80
A+
5.00
5.89
297
A
4.20
3.80
1546
3.23 / 3.63
A/A
775
10.7 / 7.8
600
700
210
14
44 / 36
60
RXS25L
RXS35L
RXS50L
550 x 765 x 285
34
550 x 765 x 285
34
1ph
4.70
4.3
10
735 x 825 x 300
47
3.30
3.3
10
6.80
6.8
20
3+E / 2.5
1/4 / 1/2
30
20
10
3+E / 1.5
inches
m
m
m
g/m
kg
dBA
dBA
1/4 / 3/8
20
15
10
1.0
46
59
1/4 / 3/8
20
15
10
20
1.2
48
61
£523.00
£476.00
£999.00
£564.00
£552.00
£1,116.00
Accessories:
1.7
48
62
£616.00
£694.00
£1,310.00
Notes:
Accessory Ref
Description
Trade Price
KRP413A1S
KRP928A2S
KLIC-DD
RTD-RA
UK.CWB90-2
UK.DT1
UK.CGS
UK.CGM
Adaptor PCB for remote on/off control - constant/pulse contact
Adaptor PCB for interface to Daikin centralised control systems
KNX interface for Split type systems
Adaptor PCB for Modbus connection and/or extended system functions
Condensing unit bracket - up to size 71
Condensate drip tray for use with UK.CWB90-2
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£75.00
£132.00
£164.00
£151.00
£37.00
£56.00
£214.00
£296.00
i)All fan coils supplied as standard with
infrared remote controller
ii)All fan coil units standard with auto restart
after power failure
iii)Wired controller, KLIC-DI and RTD-RA
options cannot be combined
iv)Minimum ambient operating
temperatures:
RXS
Cooling
Heating
-10°C
-15°C
Features:
•
•
•
•
•
•
•
•
Extremely quiet, energy efficient and can be installed against the wall or recessed
Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible
Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops
Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting
Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room
Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature
Suitable for multi model applications
Re-use of existing R22 and R407C piping possible
Price List 2014
15
SPLIT, SKY AIR HEAT PUMPS
Floor Mounted – Seasonal Smart Inverter
FVQ-C / RZQG
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
3 Phase
FVQ71C
FVQ100C
FVQ125C
FVQ140C
FVQ71C
FVQ100C
FVQ125C
FVQ140C
7.76
5.32
6.80
7.50
A++
6.80
6.31
377
A+
6.33
4.05
2188
3.37 / 3.64
A/A
1010
18 / 14
1850
600
270
39
43 / 38
55
10.80
7.44
9.50
10.80
A+
9.50
5.61
592
A+
11.30
4.20
3766
3.81 / 4.14
A/A
1245
28 / 22
1850
600
350
47
50 / 44
62
13.60
9.30
12.00
13.50
A+
12.00
5.61
748
A
11.30
3.87
4087
3.21 / 3.7
A/A
1870
28 / 24
1850
600
350
47
51 / 46
63
14.90
10.25
13.40
15.50
3.21 / 3.61
A/A
2085
30 / 26
1850
600
350
47
53 / 48
65
7.76
5.32
6.80
7.50
A++
6.80
6.31
377
A+
6.33
4.05
2188
3.37 / 3.64
A/A
1010
18 / 14
1850
600
270
39
43 / 38
55
10.80
7.44
9.50
10.80
A+
9.50
5.61
592
A+
11.30
4.20
3766
3.81 / 4.14
A/A
1245
28 / 22
1850
600
350
47
50 / 44
62
13.60
9.30
12.00
13.50
A+
12.00
5.61
748
A
11.30
3.87
4087
3.21 / 3.7
A/A
1870
28 / 24
1850
600
350
47
51 / 46
63
14.90
10.25
13.40
15.50
3.21 / 3.61
A/A
2085
30 / 26
1850
600
350
47
53 / 48
65
RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
990 x 940
x 320
78
1430 x 940
x 320
102
A
A
A
8.26
4
20
10.18
4
32
1430 x 940
x 320
102
1430 x 940
x 320
102
990 x 940
x 320
80
1430 x 940
x 320
101
15.29
4
32
17.04
4
32
3.11
4
16
3.83
4
20
3/8 / 5/8
75
30
30
3/8 / 5/8
50
30
30
4.0
52
69
2.9
48
64
£1,394.00
£1,901.00
£3,295.00
£1,068.00
£1,227.00
£2,295.00
1ph
inches
m
m
m
g/m
kg
dBA
dBA
3/8 / 5/8
50
30
30
2.9
48
64
£1,068.00
£1,191.00
£2,259.00
£1,296.00
£1,666.00
£2,962.00
Accessories:
6.41
4
20
£1,174.00
£1,584.00
£2,758.00
£1,296.00
£1,743.00
£3,039.00
3/8 / 5/8
75
30
30
4.0
52
69
£1,394.00
£2,002.00
£3,396.00
Notes:
Accessory Ref
Description
Trade Price
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
UK.CWB90-2
UK.CWB140-2
UK.DT1
UK.DT2
UK.CGM
UK.CGL
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Condensing unit bracket - up to size 71
Condensing unit bracket - sizes 100 to 140
Condensate drip tray for use with UK.CWB90-2
Condensate drip tray for use with UK.CWB140-2
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
£92.00
£190.00
£235.00
£251.00
£185.00
£37.00
£46.00
£56.00
£59.00
£296.00
£354.00
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)All fan coil units standard with auto restart
after power failure
iii)Minimum ambient operating
temperatures:
RZQG
RZQSG
Seasonally Efficient Inverter Technology gives up to 25% better efficiency than Inverter Technology
Vertical air flow pattern can be adjusted manually to match requirements in different sized interiors or irregularly shaped rooms
A wired BRC1E52A remote controller is mounted on the front of the unit (standard)
Controllable horizontal air-blow patterns, via remote control
Very efficient for use in rooms with high ceilings
Fan speed: 2 fan speeds can be selected, high or low
Re-use of existing R22 and R407C piping possible
Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)
Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart)
DIII net compatibility as standard
16
5.75
4
20
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
75
75
30
30
30
30
Refer to Installation Manual
4.0
4.0
50
51
66
67
Features:
•
•
•
•
•
•
•
•
•
•
1430 x 940
x 320
101
3ph
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
75
75
30
30
30
30
Refer to Installation Manual
4.0
4.0
50
51
66
67
£1,174.00
£1,514.00
£2,688.00
1430 x 940
x 320
101
Residential, Commercial and Industrial
Cooling
Heating
-15°C
-15°C
-20°C
-15°C
SPLIT, SKY AIR HEAT PUMPS
Floor Mounted – Seasonal Classic Inverter
FVQ-C / RZQSG
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
3 Phase
FVQ71C
FVQ100C
FVQ125C
FVQ140C
FVQ100C
FVQ125C
FVQ140C
7.28
4.99
6.80
7.50
A
6.80
5.50
433
A
6.33
3.86
2296
3.21 / 3.61
A/A
1059
18 / 14
1850
600
270
39
43 / 38
53
10.80
7.44
9.50
10.80
A
9.50
5.50
604
A+
7.60
4.01
2653
3.21 / 3.61
A/A
1480
28 / 22
1850
600
350
47
50 / 44
59
13.60
9.30
12.00
13.50
A
12.00
5.50
763
A
7.60
3.85
2763
2.81 / 3.41
C/B
2135
28 / 24
1850
600
350
47
51 / 46
60
14.90
10.25
13.40
15.50
3.01 / 3.41
B/B
2225
30 / 26
1850
600
350
47
53 / 48
63
10.80
7.44
9.50
10.80
A
9.50
5.50
377
A+
7.60
4.01
2653
3.21 / 3.61
A/A
1480
28 / 22
1850
600
350
47
50 / 44
59
13.60
9.30
12.00
13.50
A
12.00
5.50
604
A
7.60
3.85
2763
2.81 / 3.41
C/B
2135
28 / 24
1850
600
350
47
51 / 46
60
14.90
10.25
13.40
15.50
3.01 / 3.41
B/B
2225
30 / 26
1850
600
350
47
53 / 48
63
RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
770 x 900 x 320
67
8.66
4
20
3/8 / 5/8
50
30
30
2.75
49
65
£1,068.00
£881.00
£1,949.00
990 x 940 x 320
81
1ph
12.10
17.45
4
4
32
32
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
50
50
30
30
30
30
Refer to Installation Manual
2.9
2.9
53
54
69
70
£1,174.00
£1,220.00
£2,394.00
£1,296.00
£1,338.00
£2,634.00
1430 x 940 x 320
102
18.19
4
32
3/8 / 5/8
50
30
30
4.0
53
69
£1,394.00
£1,490.00
£2,884.00
990 x 940 x 320
1430 x 940 x 320
82
101
3ph
4.55
6.56
6.84
4
4
4
20
20
20
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
3/8 / 5/8
50
50
50
30
30
30
30
30
30
Refer to Installation Manual
2.9
2.9
4.0
53
54
53
69
70
69
£1,174.00
£1,257.00
£2,431.00
£1,296.00
£1,378.00
£2,674.00
£1,394.00
£1,535.00
£2,929.00
Price List 2014
17
SPLIT, SKY AIR HEAT PUMPS
Floor or Ceiling Mounted –
Inverter FLXS
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
FLXS25B
FLXS35B9
FLXS50B
2.44
1.65
2.50
3.40
A
2.50
5.19
169
A
2.50
3.80
921
3.85 / 3.54
A/B
325
7.6 / 6
490
1050
200
16
37 / 31
51
3.34
2.14
3.50
4.00
B
3.50
4.87
252
A
2.90
3.80
1068
3.1 / 3.57
B/B
565
8.6 / 6.6
490
1050
200
16
38 / 32
53
4.82
3.16
4.90
6.10
A
4.90
5.25
326
A
4.20
3.80
1546
2.85 / 3.35
C/C
860
11.4 / 8.5
490
1050
200
17
47 / 39
60
RXS25L
RXS35L
RXS50L
550 x 765 x 285
34
550 x 765 x 285
34
1ph
5.10
4.3
10
735 x 825 x 300
47
3.60
3.3
10
7.60
6.8
20
3+E / 2.5
1/4 / 1/2
30
20
10
3+E / 1.5
inches
m
m
m
g/m
kg
dBA
dBA
1/4 / 3/8
20
15
10
1.0
46
59
1/4 / 3/8
20
15
10
20
1.2
48
61
£376.00
£476.00
£852.00
£423.00
£552.00
£975.00
Accessories:
1.7
48
62
£459.00
£694.00
£1,153.00
Notes:
Accessory Ref
Description
Trade Price
KRP413A1S
KRP928A2S
KLIC-DD
RTD-RA
UK.CWB90-2
UK.DT1
UK.CGS
UK.CGM
Adaptor PCB for remote on/off control - constant/pulse contact
Adaptor PCB for interface to Daikin centralised control systems
KNX interface for Split type systems
Adaptor PCB for Modbus connection and/or extended system functions
Condensing unit bracket - up to size 71
Condensate drip tray for use with UK.CWB90-2
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£75.00
£132.00
£164.00
£151.00
£37.00
£56.00
£214.00
£296.00
i)All fan coils supplied as standard with
infrared remote controller
ii)Wired controller, KLIC-DI and RTD-RA
options cannot be combined
iii)All fan coil units standard with auto restart
after power failure
iv)Minimum ambient operating
temperatures:
RXS
Cooling
Heating
-10°C
-15°C
Features:
• Can be installed EITHER as ceiling mounted OR wall unit
•Vertical auto swing: flaps automatically swing up and down to ensure efficient air and temperature distribution in both floor level and ceiling
suspended installation
• Home Leave setting maintains pre-set temperature during periods of extended absence
• Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops
• Fan speed: 5 fan speeds can be selected, high to super low
• Suitable for multi model applications
• Re-use of existing R22 and R407C piping possible
18
Residential, Commercial and Industrial
SPLIT, SKY AIR HEAT PUMPS
Ceiling Suspended – Inverter
FHQ-C
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
FHQ35C
FHQ50C
FHQ60C
3.32
2.58
3.40
4.00
A++
3.40
6.18
193
A+
3.10
4.43
981
3.58 / 4.08
A/A
475
14 / 10
235
960
690
24
36 / 31
53
4.92
3.52
5.00
6.00
A+
5.00
5.87
298
A
4.35
3.86
1578
3.18 / 3.35
B/C
785
15 / 10
235
960
690
25
37 / 32
54
5.57
3.93
5.70
7.20
A+
5.70
6.02
332
A
4.71
3.87
1705
3.26 / 3.32
A/C
875
19.5 / 15
235
1270
690
31
37 / 33
54
RXS35L
RXS50L
RXS60L
550 x 765 x 285
34
735 x 825 x 300
48
1.2
48
61
735 x 825 x 300
47
1ph
7.3
6.8
20
3+E / 1.5
1/4 / 1/2
30
20
10
20.0
1.7
48
62
£710.00
£552.00
£1,262.00
£770.00
£694.00
£1,464.00
£845.00
£740.00
£1,585.00
4.1
4.3
10
1/4 / 3/8
20
15
10
Accessories:
7.8
9.4
20
1/4 / 1/2
30
20
10
1.5
49
62
Notes:
Accessory Ref
Description
Trade Price
BRC7G53
EKRORO4
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
UK.CWB90-2
UK.DT1
UK.CGS
UK.CGM
KDDQ50A140
Wireless remote controller
Remote on/off control interface kit
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock.
Energy control PCB for Sky Air and VRV.
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Condensing unit bracket - up to size 71
Condensate drip tray for use with UK.CWB90-2
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
Fresh air intake kit for up to 20% fresh air
£152.00
£29.00
£92.00
£190.00
£235.00
POA
£185.00
£47.00
£89.00
£93.00
£37.00
£56.00
£214.00
£296.00
£158.00
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)BRC7GA53 Trade price will be reduced
by £76.00 if ordered in place of the
BRC1E52A
iii)All fan coil units standard with auto restart
after power failure
iv)Minimum ambient operating
temperatures:
RXS
Cooling
Heating
-10°C
-15°C
Features:
•
•
•
•
•
Suitable for ceiling heights of up to 3.8m without loss of capacity
Vertical auto-swing function of flaps ensures efficient air and temperature distribution
Forced off: The optional forced off feature enables the unit to switch off automatically, for example when a window is opened
Re-use of existing R22 and R407C piping possible
Suitable for Twin, Triple and Double Twin applications
Price List 2014
19
SPLIT, SKY AIR HEAT PUMPS
Ceiling Suspended – Seasonal Smart Inverter
FHQ-C Seasonal Smart
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
3 Phase
FHQ71C
FHQ100C
FHQ125C
FHQ140C
FHQ71C
FHQ100C
FHQ125C
FHQ140C
7.76
5.32
6.80
7.50
A++
6.80
6.95
342
A+
7.60
4.32
2462
3.82 / 4.13
A/A
890
20.5 / 14
235
1270
690
32
38 / 34
53
10.80
7.44
9.50
10.80
A++
9.50
6.11
544
A++
11.30
4.61
3431
4.13 / 4.42
A/A
1245
28 / 20
235
1590
690
38
42 / 34
56
13.60
9.30
12.00
13.50
A+
12.00
6.01
698
A+
14.13
4.23
4676
3.52 / 3.89
A/A
1790
31 / 23
235
1590
690
38
44 / 37
59
14.90
10.25
13.40
15.50
3.31 / 3.63
A/A
2025
34 / 24
235
1590
690
38
46 / 38
60
7.76
5.32
6.80
7.50
A++
6.80
6.95
342
A+
7.60
4.32
2462
3.82 / 4.13
A/A
890
20.5 / 14
235
1270
690
32
38 / 34
53
10.80
7.44
9.50
10.80
A++
9.50
6.11
544
A++
11.30
4.61
3431
4.13 / 4.42
A/A
1245
28 / 20
235
1590
690
38
42 / 34
56
13.60
9.30
12.00
13.50
A+
12.00
6.01
698
A+
14.13
4.23
4676
3.52 / 3.89
A/A
1790
31 / 23
235
1590
690
38
44 / 37
59
14.90
10.25
13.40
15.50
3.31 / 3.63
A/A
2025
34 / 24
235
1590
690
38
46 / 38
60
RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
990 x 940 x 320
78
7.27
4
20
3/8 / 5/8
50
30
30
2.9
48
64
£989.00
£1,191.00
£2,180.00
1430 x 940 x 320
102
1ph
10.18
14.63
4
4
32
32
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
75
75
30
30
30
30
Refer to Installation Manual
4.0
4.0
50
51
66
67
£1,051.00
£1,514.00
£2,565.00
£1,315.00
£1,666.00
£2,981.00
990 x 940 x 320
80
16.55
4
32
2.74
4
16
3/8 / 5/8
75
30
30
3/8 / 5/8
50
30
30
4.0
52
69
2.9
48
64
£1,563.00
£1,901.00
£3,464.00
£989.00
£1,227.00
£2,216.00
Accessories:
1430 x 940 x 320
101
3ph
3.83
5.50
4
4
20
20
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
75
75
30
30
30
30
Refer to Installation Manual
4.0
4.0
50
51
66
67
£1,051.00
£1,584.00
£2,635.00
£1,315.00
£1,743.00
£3,058.00
3/8 / 5/8
75
30
30
4.0
52
69
£1,563.00
£2,002.00
£3,565.00
Notes:
Accessory Ref
Description
Trade Price
BRC7G53
EKRORO4
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
UK.CWB90-2
UK.CWB140-2
UK.DT1
UK.DT2
UK.CGS
UK.CGM
UK.CGL
KDDQ50A140
Wireless remote controller
Remote on/off control interface kit
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Condensing unit bracket - up to size 71
Condensing unit bracket - sizes 100 to 140
Condensate drip tray for use with UK.CWB90-2
Condensate drip tray for use with UK.CWB140-2
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
Fresh air intake kit for up to 20% fresh air
£152.00
£29.00
£92.00
£190.00
£235.00
£251.00
£185.00
£47.00
£89.00
£93.00
£37.00
£46.00
£56.00
£59.00
£214.00
£296.00
£354.00
£158.00
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)BRC7GA53 Trade price will be reduced
by £76.00 if ordered in place of the
BRC1E52A
iii)All fan coil units standard with auto restart
after power failure
iv)Minimum ambient operating
temperatures:
RZQG
RZQSG
Cooling
Heating
-15°C
-15°C
-20°C
-15°C
Features:
• Suitable for ceiling heights of up to 3.8m without loss of capacity
•Seasonally Efficient Inverter Technology gives up to 25% better efficiency
than inverter technology
•Forced off: The optional forced off enables the unit to switch off
automatically, for example when a window is opened
• Re-use of existing R22 and R407C piping possible
20
6.23
4
20
Residential, Commercial and Industrial
• Suitable for Twin, Triple and Double Twin applications
•Comms, computer and server room cooling possible with
EDP setting (Seasonal Smart)
•Selectable evaporating & condensing temperature for greater
operating efficiency (Seasonal Smart)
• DIII net compatibility as standard
SPLIT, SKY AIR HEAT PUMPS
Ceiling Suspended – Seasonal Classic Inverter
FHQ-C Seasonal Classic
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
3 Phase
FHQ71C
FHQ100C
FHQ125C
FHQ140C
FHQ100C
FHQ125C
FHQ140C
7.28
4.99
6.80
7.50
A+
6.80
5.61
424
A
7.60
3.90
2727
3.46 / 4
A/A
983
20.5 / 14
235
1270
690
32
38 / 34
53
10.80
7.44
9.50
10.80
A+
9.50
5.61
592
A
7.60
3.91
2721
3.21 / 3.61
A/A
1480
28 / 20
235
1590
690
38
42 / 34
56
13.60
9.30
12.00
13.50
A+
12.00
5.61
748
A+
7.60
4.01
2653
2.89 / 3.62
C/A
2075
31 / 23
235
1590
690
38
44 / 37
59
14.90
10.25
13.40
15.50
3.01 / 3.41
B/B
2225
34 / 24
235
1590
690
38
46 / 38
60
10.80
7.44
9.50
10.80
A+
9.50
5.61
592
A
7.60
3.91
2721
3.21 / 3.61
A/A
1480
28 / 20
235
1590
690
38
42 / 34
56
13.60
9.30
12.00
13.50
A+
12.00
5.61
748
A+
7.60
4.01
2653
2.89 / 3.62
C/A
2075
31 / 23
235
1590
690
38
44 / 37
59
14.90
10.25
13.40
15.50
3.01 / 3.41
B/B
2225
34 / 24
235
1590
690
38
46 / 38
60
RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
770 x 900 x 320
67
8.05
4
20
3/8 / 5/8
50
30
30
2.75
49
65
£989.00
£881.00
£1,870.00
990 x 940 x 320
81
1ph
12.10
16.96
4
4
32
32
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
50
50
30
30
30
30
Refer to Installation Manual
2.9
2.9
53
54
69
70
£1,051.00
£1,220.00
£2,271.00
£1,315.00
£1,338.00
£2,653.00
1430 x 940 x 320
102
18.19
4
32
3/8 / 5/8
50
30
30
4.0
53
69
£1,563.00
£1,490.00
£3,053.00
990 x 940 x 320
1430 x 940 x 320
82
101
3ph
4.52
6.34
6.80
4
4
4
20
20
20
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
3/8 / 5/8
50
50
50
30
30
30
30
30
30
Refer to Installation Manual
2.9
2.9
4.0
53
54
53
69
70
69
£1,051.00
£1,257.00
£2,308.00
£1,315.00
£1,378.00
£2,693.00
£1,563.00
£1,535.00
£3,098.00
Price List 2014
21
SPLIT, SKY AIR HEAT PUMPS
Ceiling Suspended – Inverter
AHQ-C / AZQS
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
3 Phase
AHQ71C
AHQ100C
AHQ125C
AHQ140C
AHQ100C
AHQ125C
AHQ140C
7.28
4.99
6.80
7.50
B
6.80
4.65
511
A
6.33
3.80
2332
3.03 / 3.05
B/D
1120
23.8 / 18.9
260
1320
634
38
49 / 46
52
10.80
7.44
9.50
10.80
B
9.50
4.60
723
A
7.60
3.80
2800
2.62 / 3.41
D/B
1810
31.1 / 24.8
260
1538
634
45
51 / 45
73
13.60
9.30
12.10
13.50
2.63 / 3.61
D/A
2300
34.4 / 27.2
260
1786
634
54
52 / 47
73
14.90
10.25
13.00
15.50
3.01 / 3.41
B/B
2159
43.9 / 28.3
285
1902
680
70
53 / 47
75
10.80
7.44
9.50
10.80
B
9.50
4.60
723
A
7.60
3.80
2800
2.62 / 3.41
D/B
1810
31.1 / 24.8
260
1538
634
45
51 / 45
73
13.60
9.30
12.10
13.50
2.63 / 3.61
D/A
2300
34.4 / 27.2
260
1786
634
54
52 / 47
73
14.90
10.25
13.00
15.50
3.01 / 3.41
B/B
2159
43.9 / 28.3
285
1902
680
70
53 / 47
75
AZQS71BV1
AZQS100BV1
AZQS125BV1
AZQS140BV1
AZQS100BY1
AZQS125BY1
770x900x320
67
data-book
48
64
990x940x320
81
1~
14.79
18.80
4
4
32
32
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
50
50
30
30
30
30
data-book
data-book
data-book
53
54
70
71
£665.00
£857.00
£1,522.00
£756.00
£1,019.00
£1,775.00
9.11
4
20
3/8 / 5/8
30
15
30
£950.00
£1,122.00
£2,072.00
1430x940x320
102
data-book
53
70
data-book
53
70
£756.00
£1,067.00
£1,823.00
£950.00
£1,174.00
£2,124.00
£1,098.00
£1,347.00
£2,445.00
4.92
4
20
3/8 / 5/8
50
30
30
3/8 / 5/8
50
30
30
data-book
53
70
£1,098.00
£1,280.00
£2,378.00
5.87
4
20
3/8 / 5/8
50
30
30
Notes:
Accessory Ref
Description
Trade Price
R04084124324
UK.CWB90-2
UK.CWB140-2
UK.DT1
UK.DT2
UK.CGM
UK.CGL
PCB Adaptor for group control (1 per fan-coil)
Condensing unit bracket - up to size 71
Condensing unit bracket - sizes 100 to 140
Condensate drip tray for use with UK.CWB90-2
Condensate drip tray for use with UK.CWB140-2
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
£82.00
£37.00
£46.00
£56.00
£59.00
£296.00
£354.00
Features:
Hard wired remote ARCWB as standard
Long airflow
3 step fan speed and auto mode
Turbo mode to quickly heat / cool room
Ideal for rooms with solid or high ceilings
22
AZQS140BY1
1430x940x320
101
3~
6.25
4
20
3+E / 1.5
3/8 / 5/8
50
30
30
data-book
data-book
54
71
17.66
4
32
Accessories:
•
•
•
•
•
990x940x320
81
Residential, Commercial and Industrial
i)Fan-coils supplied with both ARCWB hard
wired remote & infra-red remote
ii)Replacement Technology not applicable
to AZQS
iii)All fan coil units standard with auto restart
after power failure
iv)Minimum ambient operating
temperature:
AZQS
Cooling
Heating
-5°C
-15°C
SPLIT, SKY AIR HEAT PUMPS
600x600 Fully Flat Cassette
FFQ
Indoor Units
Capacity
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Seasonal Efficiency
(EN14825)
Pdesign
COOLING
SEER
Annual Energy Consumption
Energy Label
Seasonal Efficiency
(EN14825)
Pdesign
HEATING
SCOP
Annual Energy Consumption
Nominal Efficiency
EER / COP
Energy Label
Annual Energy Consumption
Air Flow Rate
High / Low
Dimensions
Height
(with Decoration Panel) Width
Depth
Weight (with Decoration Panel)
Sound Pressure
High / Low
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
FFQ25C
FFQ35C
FFQ50C
FFQ60C
2.44
1.81
2.50
3.20
A++
2.50
6.11
143
A+
2.31
4.24
763
4.46 / 3.9
A/A
280
9 / 6.5
260 (306)
575 (620)
575 (620)
17.5 (20.2)
31 / 25
48
3.32
2.28
3.40
4.00
A++
3.40
6.32
188
A+
3.10
4.10
1059
3.7 / 3.5
A/B
460
10 / 6.5
260 (306)
575 (620)
575 (620)
17.5 (20.2)
34 / 25
51
4.62
3.40
4.70
5.50
A+
5.00
5.93
295
A
3.84
3.90
1378
3.21 / 3.49
A/B
780
12 / 7.5
260 (306)
575 (620)
575 (620)
17.5 (20.2)
39 / 27
56
5.72
4.20
5.80
7.00
A+
5.80
5.71
349
A+
3.96
4.04
1373
3.02 / 3.41
B/B
945
14.5 / 9.5
260 (306)
575 (620)
575 (620)
17.5 (20.2)
43 / 32
60
RXS25L
RXS35L
RXS50L
RXS60L
550 x 765 x 285
34
550 x 765 x 285
34
735 x 825 x 300
47
735 x 825 x 300
48
4.00
3.3
10
4.00
4.3
10
6.90
6.8
20
8.30
9.4
20
1/4 / 3/8
20
15
10
1/4 / 3/8
20
15
10
1/4 / 1/2
30
20
10
1/4 / 1/2
30
20
10
1.0
46
61
1.2
48
61
1.7
48
62
1.5
49
62
£663.00
£476.00
£1,139.00
£727.00
£552.00
£1,279.00
£802.00
£694.00
£1,496.00
£849.00
£740.00
£1,589.00
1ph
A
A
A
3+E / 1.5
inches
m
m
m
g/m
kg
dBA
dBA
20
Accessories:
Notes:
Accessory Ref
Description
Trade Price
BYFQ60CW
BYFQ60CS
BYFQ60B3
BRYQ60AW
BRYQ60AS
BRC7F530W
BRC7F530S
BRC7EB530W
BDBHQ44C60
KRP4A53/UK.FB2
KRP1B57/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
UK.CWB90-2
UK.DT1
UK.CGS
UK.CGM
Fully Flat Cassette Decoration Panel - White
Fully Flat Cassette Decoration Panel - Sliver
Fully Flat Cassette Decoration Panel - Old Style (FFQ-B9V looks)
Integral PIR Sensor for Fully Flat cassette White decoration panel. Enables Energy Saving functions
Integral PIR Sensor for Fully Flat Cassette Silver decoration panel. Enables Energy Saving functions
Wireless remote controller for White Ceiling Decoration Panel
Wireless remote controller for Silver Ceiling Decoration Panel
Wireless remote for Fully Flat Cassette Old Style Decoration Panel
Sealing member for decoration panel-FFQ,FXZQ
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Adaptor PCB for Interlock to fresh air fan
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Condensing unit bracket - up to size 71
Condensate drip tray for use with UK.CWB90-2
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£198.00
£198.00
£170.00
£99.00
£99.00
£152.00
£152.00
£152.00
£91.00
£92.00
£100.00
£190.00
£235.00
£251.00
£185.00
£47.00
£89.00
£93.00
£37.00
£56.00
£214.00
£296.00
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
i)Infrared remote Trade price will be
reduced by £76.00 if ordered instead of
BRC1E52A
ii)All fan coil units standard with auto restart
after power failure
iv)All fan coils suppled as standard
with BYFQ60CW White fully flat
decoration panel
v)Minimum ambient operating
temperatures:
RXS
Cooling
Heating
-10°C
-15°C
Features:
•
•
•
•
•
•
•
Installed into suspended ceiling grids without cutting surrounding tiles
Home Leave setting maintains pre-set temperature during periods of extended absence
Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature
Vertical auto-swing function: flaps automatically swing up and down to ensure efficient air and temperature distribution which also prevents ceiling soiling
3 fan speeds can be selected: high, medium and low
Suitable for Twin, Triple and Double Twin applications. Also suitable for multi model applications
Re-use of existing R22 and R407C piping possible
Price List 2014
23
SPLIT, SKY AIR HEAT PUMPS
High COP Roundflow Cassette –
Seasonal Smart Inverter FCQHG / RZQG
Indoor Units
Capacity
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
COOLING
SEER
Annual Energy Consumption
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
HEATING
SCOP
Annual Energy Consumption
Nominal Efficiency
EER / COP
Energy Label
Annual Energy Consumption
Air Flow Rate
High / Low
Dimensions
Height
(with Decoration Panel) Width
Depth
Weight (with Decoration Panel)
Sound Pressure
High / Low
Sound Power
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
FCQHG71F
7.76
5.32
6.80
7.50
A++
6.80
7.00
340
A+
7.60
4.54
2343
4.09 / 4.8
A/A
830
21.2 / 12.2
288(348)
840 (950)
840 (950)
25 (30.4)
36 / 29
53
Single Phase
FCQHG100F FCQHG125F
10.80
13.60
7.44
9.30
9.50
12.00
10.80
13.50
A++
A++
9.50
12.00
7.00
6.61
475
635
A++
A++
11.30
12.66
4.80
4.63
3295
3829
4.42 / 4.99
4 / 4.4
A/A
A/A
1075
1500
32.3 / 19
33.5 / 19.9
288 (348)
288 (348)
840 (950)
840 (950)
840 (950)
840 (950)
26 (31.4)
26 (31.4)
44 / 33
45 / 35
61
61
FCQHG140F
14.90
10.25
13.40
15.50
3.35 / 4.12
A/A
2000
33.5 / 21.1
288 (348)
840 (950)
840 (950)
26 (31.4)
45 / 37
61
FCQHG71F
7.76
5.32
6.80
7.50
A++
6.80
7.00
340
A+
7.60
4.54
2343
4.09 / 4.8
A/A
830
21.2 / 12.2
288(348)
840 (950)
840 (950)
25 (30.4)
36 / 29
53
3 Phase
FCQHG100F FCQHG125F
10.80
13.60
7.44
9.30
9.50
12.00
10.80
13.50
A++
A++
9.50
12.00
7.00
6.61
475
635
A++
A++
11.30
12.66
4.80
4.63
3295
3829
4.42 / 4.99
4 / 4.4
A/A
A/A
1075
1500
32.3 / 19
33.5 / 19.9
288 (348)
288 (348)
840 (950)
840 (950)
840 (950)
840 (950)
26 (31.4)
26 (31.4)
44 / 33
45 / 35
61
61
RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1
990 x 940 x 320
1430 x 940 x 320
990 x 940 x 320
1430 x 940 x 320
78
102
80
101
1ph
3ph
6.78
8.79
12.26
16.35
2.55
3.31
4.61
6.15
4
4
4
4
4
4
4
4
20
32
32
32
16
20
20
20
3+E / 1.5
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
3/8 / 5/8
3/8 / 5/8
3/8 / 5/8
3/8 / 5/8
3/8 / 5/8
3/8 / 5/8
50
75
75
75
50
75
75
75
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
Refer to Installation Manual
Refer to Installation Manual
2.9
4.0
4.0
4.0
2.9
4.0
4.0
4.0
48
50
51
52
48
50
51
52
64
66
67
69
64
66
67
69
£829.00
£1,191.00
£2,020.00
£940.00
£1,514.00
£2,454.00
£1,028.00
£1,666.00
£2,694.00
£1,239.00
£1,901.00
£3,140.00
£829.00
£1,227.00
£2,056.00
Accessories:
£940.00
£1,584.00
£2,524.00
£1,028.00
£1,743.00
£2,771.00
£1,239.00
£2,002.00
£3,241.00
Notes:
Accessory Ref
Description
Trade Price
BRC7FA532F
BYCQ140DG
BYCQ140DW
BRYQ140A
KDBHQ55B140
KDDQ55B140 1&2
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
UK.CWB90-2
UK.CWB140-2
UK.DT1
UK.DT2
UK.CGM
UK.CGL
Wireless remote controller
Roundflow cassette decoration panel with self cleaning filter
Roundflow cassette decoration panel - white with white louvres
Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions
Sealing member for air discharge outlet
Fresh air intake kit for up to 20% fresh air - 2 part kit
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Condensing unit bracket - up to size 71
Condensing unit bracket - sizes 100 to 140
Condensate drip tray for use with UK.CWB90-2
Condensate drip tray for use with UK.CWB140-2
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
£152.00
£310.00
£160.00
£99.00
£90.00
£249.00
£92.00
£190.00
£235.00
£251.00
£185.00
£47.00
£89.00
£93.00
£37.00
£46.00
£56.00
£59.00
£296.00
£354.00
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)BRC7FA532F Trade price will be reduced
by £76.00 if ordered in place of the
BRC1E52A
iii)All fan coil units standard with auto restart
after power failure
iv)All fan coils suppled as standard with
BYCQ140D Decoration panel
v)BYCQ140DW / BYCQ140DG Trade prices
will be reduced by £142.00 if ordered in
place of standard decoration panel
vi)Minimum ambient operating
temperatures:
RZQG
RZQSG
Features:
• The FCQHG model is designed for 2014 ErP regulations and has one of the highest COP values on the market
• The unique 360° radial air pattern ensures uniform air flow and temperature distribution
• Air flow flexibility: a wide selection of 23 different air flow patterns accessible via remote controller
• Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels
•Optional Self Cleaning Filter The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost
• Optional Fresh Air intake (up to 20%) possible
• Suitable for Twin, Triple and Double Twin applications
• Re-use of existing R22 and R407C piping possible
• Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)
• Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart)
• DIII net compatibility as standard
24
FCQHG140F
14.90
10.25
13.40
15.50
3.35 / 4.14
A/A
2000
33.5 / 21.1
288 (348)
840 (950)
840 (950)
26 (31.4)
45 / 37
61
Residential, Commercial and Industrial
Cooling
Heating
-15°C
-15°C
-20°C
-15°C
SPLIT, SKY AIR HEAT PUMPS
High COP Roundflow Cassette –
Seasonal Classic Inverter FCQHG / RZQSG
Indoor Units
Single Phase
Capacity
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
COOLING
SEER
Annual Energy Consumption
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
HEATING
SCOP
Annual Energy Consumption
Nominal Efficiency
EER / COP
Energy Label
Annual Energy Consumption
Air Flow Rate
High / Low
Dimensions
Height
(with Decoration Panel) Width
Depth
Weight (with Decoration Panel)
Sound Pressure
High / Low
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
3 Phase
FCQHG71F
FCQHG100F
FCQHG125F
FCQHG140F
FCQHG100F
FCQHG125F
FCQHG140F
7.28
4.99
6.80
7.50
A++
6.80
6.50
366
A+
7.60
4.15
2563
3.5 / 4.1
A/A
1059
21.2 / 12.2
288(348)
840 (950)
840 (950)
25 (30.4)
36 / 29
53
10.80
7.44
9.50
10.80
A++
9.50
6.70
496
A+
8.03
4.30
2614
3.7 / 4.3
A/A
1285
32.3 / 19
288 (348)
840 (950)
840 (950)
26 (31.4)
44 / 33
61
13.60
9.30
12.00
13.50
A
12.00
5.40
777
A+
8.03
4.10
2741
3.23 / 3.75
A/A
1855
33.5 / 19.9
288 (348)
840 (950)
840 (950)
26 (31.4)
45 / 35
61
14.90
10.25
13.40
15.50
3.21 / 3.61
A/A
2085
33.5 / 21.1
288 (348)
840 (950)
840 (950)
26 (31.4)
45 / 37
61
10.80
7.44
9.50
10.80
A++
9.50
6.70
496
A+
8.03
4.30
2614
3.7 / 4.3
A/A
1285
32.3 / 19
288 (348)
840 (950)
840 (950)
26 (31.4)
44 / 33
61
13.60
9.30
12.00
13.50
A
12.00
5.40
777
A+
8.03
4.10
2741
3.23 / 3.75
A/A
1855
33.5 / 19.9
288 (348)
840 (950)
840 (950)
26 (31.4)
45 / 35
61
14.90
10.25
13.40
15.50
3.21 / 3.61
A/A
2085
33.5 / 21.1
288 (348)
840 (950)
840 (950)
26 (31.4)
45 / 37
61
RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
770 x 900 x 320
67
7.93
4
20
3/8 / 5/8
50
30
30
2.75
49
65
£829.00
£881.00
£1,710.00
990 x 940 x 320
81
1ph
10.50
15.16
4
4
32
32
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
50
50
30
30
30
30
Refer to Installation Manual
2.9
2.9
53
54
69
70
£940.00
£1,220.00
£2,160.00
£1,028.00
£1,338.00
£2,366.00
1430 x 940 x 320
102
17.04
4
32
3/8 / 5/8
50
30
30
4.0
53
69
£1,239.00
£1,490.00
£2,729.00
990 x 940 x 320
1430 x 940 x 320
82
101
3ph
3.93
5.67
6.37
4
4
4
20
20
20
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
3/8 / 5/8
50
50
50
30
30
30
30
30
30
Refer to Installation Manual
2.9
2.9
4.0
53
54
53
69
70
69
£940.00
£1,257.00
£2,197.00
£1,028.00
£1,378.00
£2,406.00
£1,239.00
£1,535.00
£2,774.00
Self Cleaning Panel
Daikin’s Roundflow Cassette can be equipped with a special
filter that cleans itself once a day, ensuring consistent,
optimum performance.
Result?
Efficiency gains up to 50% compared to standard panels.*
The dust collected during daily auto-cleaning is stored in
a dust box that can hold up to 12 months of dust, with an
indicator light showing when to clean the dust box.
Under normal circumstances, annual or bi-annual cleaning
by in-house maintenance personnel using an ordinary
vacuum cleaner is all that is needed: no ladders, no need to
touch the cassette panel or come in contact with the dust.
* Reference: Coral, Wolverhampton case study.
Price List 2014
25
SPLIT, SKY AIR HEAT PUMPS
Compact Roundflow Cassette –
Seasonal Smart Inverter FCQG / RZQG
Indoor Units
Single Phase
Capacity
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
COOLING
SEER
Annual Energy Consumption
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
HEATING
SCOP
Annual Energy Consumption
Nominal Efficiency
EER / COP
Energy Label
Annual Energy Consumption
Air Flow Rate
High / Low
Dimensions
Height
(with Decoration Panel) Width
Depth
Weight (with Decoration Panel)
Sound Pressure
High / Low
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
3 Phase
FCQG71F
FCQG100F
FCQG125F
FCQG140F
FCQG71F
FCQG100F
FCQG125F
FCQG140F
7.76
5.32
6.80
7.50
A++
6.80
6.80
350
A+
6.33
4.20
2110
3.39 / 3.97
A/A
1005
15 / 9.1
204 (264)
840 (950)
840 (950)
21 (26.4)
33 / 28
51
10.80
7.44
9.50
10.80
A++
9.50
6.80
488
A++
11.30
4.61
3431
3.87 / 4.15
A/A
1225
22.8 / 12.4
246 (306)
840 (950)
840 (950)
24 (29.4)
37 / 29
54
13.60
9.30
12.00
13.50
A+
12.00
6.00
700
A+
12.66
4.10
4322
3.73 / 3.63
A/A
1610
26 / 12.4
246 (306)
840 (950)
840 (950)
24 (29.4)
41 / 29
58
14.90
10.25
13.40
15.50
3.21 / 3.61
A/A
2085
26 / 12.4
246 (306)
840 (950)
840 (950)
24 (29.4)
41 / 29
58
7.76
5.32
6.80
7.50
A++
6.80
6.80
350
A+
6.33
4.20
2110
3.39 / 3.97
A/A
1005
15 / 9.1
204 (264)
840 (950)
840 (950)
21 (26.4)
33 / 28
51
10.80
7.44
9.50
10.80
A++
9.50
6.80
488
A++
11.30
4.61
3431
3.87 / 4.15
A/A
1225
22.8 / 12.4
246 (306)
840 (950)
840 (950)
24 (29.4)
37 / 29
54
13.60
9.30
12.00
13.50
A+
12.00
6.00
700
A+
12.66
4.10
4322
3.73 / 3.63
A/A
1610
26 / 12.4
246 (306)
840 (950)
840 (950)
24 (29.4)
41 / 29
58
14.90
10.25
13.40
15.50
3.21 / 3.61
A/A
2085
26 / 12.4
246 (306)
840 (950)
840 (950)
24 (29.4)
41 / 29
58
RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
990 x 940 x 320
78
8.21
4
20
3/8 / 5/8
50
30
30
2.9
48
64
£829.00
£1,191.00
£2,020.00
1430 x 940 x 320
102
1ph
10.01
13.16
4
4
32
32
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
75
75
30
30
30
30
Refer to Installation Manual
4.0
4.0
50
51
66
67
£940.00
£1,514.00
£2,454.00
£1,028.00
£1,666.00
£2,694.00
990 x 940 x 320
80
17.04
4
32
3.09
4
16
3/8 / 5/8
75
30
30
3/8 / 5/8
50
30
30
4.0
52
69
2.9
48
64
£1,239.00
£1,901.00
£3,140.00
£829.00
£1,227.00
£2,056.00
Accessories:
1430 x 940 x 320
101
3ph
3.77
4.95
4
4
20
20
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
75
75
30
30
30
30
Refer to Installation Manual
4.0
4.0
50
51
66
67
£940.00
£1,584.00
£2,524.00
3/8 / 5/8
75
30
30
4.0
52
69
£1,239.00
£2,002.00
£3,241.00
Notes:
Accessory Ref
Description
Trade Price
BRC7FA532F
BYCQ140DG
BYCQ140DW
BRYQ140A
KDBHQ55B140
KDDQ55B140 1&2
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
UK.CWB90-2
UK.CWB140-2
UK.DT1
UK.DT2
UK.CGM
UK.CGL
Wireless remote controller
Roundflow cassette decoration panel with self cleaning filter
Roundflow cassette decoration panel - white with white louvres
Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions
Sealing member for air discharge outlet
Fresh air intake kit for up to 20% fresh air - 2 part kit
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Condensing unit bracket - up to size 71
Condensing unit bracket - sizes 100 to 140
Condensate drip tray for use with UK.CWB90-2
Condensate drip tray for use with UK.CWB140-2
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
£152.00
£310.00
£160.00
£99.00
£90.00
£249.00
£92.00
£190.00
£235.00
£251.00
£185.00
£47.00
£89.00
£93.00
£37.00
£46.00
£56.00
£59.00
£296.00
£354.00
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)BRC7FA532F Trade price will be reduced
by £76.00 if ordered in place of the
BRC1E52A
iii)All fan coil units standard with auto restart
after power failure
iv)All fan coils suppled as standard with
BYCQ140D Decoration panel
v)BYCQ140DW / BYCQ140DG Trade prices
will be reduced by £142.00 if ordered in
place of standard decoration panel
vi)Minimum ambient operating
temperatures:
RZQG
RZQSG
Features:
• FCQG is a compact cassette designed to suit installation in narrower ceiling voids
• The unique 360° radial air pattern ensures uniform air flow and temperature distribution
• Air flow flexibility: a wide selection of 23 different air flow patterns accessible via remote controller
• Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels
•Optional Self Cleaning Filter: The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost
•Optional Fresh Air intake (up to 20%) possible
• Re-use of existing R22 and R407C piping possible
• Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)
• Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart)
• DIII net compatibility as standard
26
£1,028.00
£1,743.00
£2,771.00
6.41
4
20
Residential, Commercial and Industrial
Cooling
Heating
-15°C
-15°C
-20°C
-15°C
SPLIT, SKY AIR HEAT PUMPS
Compact Roundflow Cassette –
Seasonal Classic Inverter FCQG / RZQSG
Indoor Units
Single Phase
Capacity
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
COOLING
SEER
Annual Energy Consumption
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
HEATING
SCOP
Annual Energy Consumption
Nominal Efficiency
EER / COP
Energy Label
Annual Energy Consumption
Air Flow Rate
High / Low
Dimensions
Height
(with Decoration Panel) Width
Depth
Weight (with Decoration Panel)
Sound Pressure
High / Low
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
3 Phase
FCQG71F
FCQG100F
FCQG125F
FCQG140F
FCQG100F
FCQG125F
FCQG140F
7.28
4.99
6.80
7.50
A++
6.80
6.10
390
A+
6.33
4.10
2162
3.21 / 3.61
A/A
971
15 / 9.1
204 (264)
840 (950)
840 (950)
21 (26.4)
33 / 28
51
10.80
7.44
9.50
10.80
A++
9.50
6.50
511
A+
7.60
4.10
2595
3.3 / 3.54
A/B
1440
22.8 / 12.4
246 (306)
840 (950)
840 (950)
24 (29.4)
37 / 29
54
13.60
9.30
12.00
13.50
A
12.00
5.30
792
A+
8.03
4.01
2803
3.21 / 3.41
A/B
1870
26 / 12.4
246 (306)
840 (950)
840 (950)
24 (29.4)
41 / 29
58
14.90
10.25
13.40
15.50
3.01 / 3.41
B/B
2225
26 / 12.4
246 (306)
840 (950)
840 (950)
24 (29.4)
41 / 29
58
10.80
7.44
9.50
10.80
A++
9.50
6.50
511
A+
7.60
4.10
2595
3.3 / 3.54
A/B
1440
22.8 / 12.4
246 (306)
840 (950)
840 (950)
24 (29.4)
37 / 29
54
13.60
9.30
12.00
13.50
A
12.00
5.30
792
A+
8.03
4.01
2803
3.21 / 3.41
A/B
1870
26 / 12.4
246 (306)
840 (950)
840 (950)
24 (29.4)
41 / 29
58
14.90
10.25
13.40
15.50
3.01 / 3.41
B/B
2225
26 / 12.4
246 (306)
840 (950)
840 (950)
24 (29.4)
41 / 29
58
RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
770 x 900 x 320
67
8.66
4
20
3/8 / 5/8
50
30
30
2.75
49
65
£829.00
£881.00
£1,710.00
990 x 940 x 320
81
1ph
11.77
15.29
4
4
32
32
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
50
50
30
30
30
30
Refer to Installation Manual
2.9
2.9
53
54
69
70
£940.00
£1,220.00
£2,160.00
£1,028.00
£1,338.00
£2,366.00
1430 x 940 x 320
102
18.19
4
32
3/8 / 5/8
50
30
30
4.0
53
69
£1,239.00
£1,490.00
£2,729.00
990 x 940 x 320
1430 x 940 x 320
82
101
3ph
4.40
5.72
6.80
4
4
4
20
20
20
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
3/8 / 5/8
50
50
50
30
30
30
30
30
30
Refer to Installation Manual
2.9
2.9
4.0
53
54
53
69
70
69
£940.00
£1,257.00
£2,197.00
£1,028.00
£1,378.00
£2,406.00
£1,239.00
£1,535.00
£2,774.00
Price List 2014
27
SPLIT, SKY AIR HEAT PUMPS
Compact Roundflow Cassette – Inverter
FCQG / RXS
Indoor Units
Capacity
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Seasonal Efficiency
(EN14825)
Pdesign
COOLING
SEER
Annual Energy Consumption
Energy Label
Seasonal Efficiency
(EN14825)
Pdesign
HEATING
SCOP
Annual Energy Consumption
Nominal Efficiency
EER / COP
Energy Label
Annual Energy Consumption
Air Flow Rate
High / Low
Dimensions
Height
(with Decoration Panel) Width
Depth
Weight (with Decoration Panel)
Sound Pressure
High / Low
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
FCQG35F
FCQG50F
FCQG60F
3.32
2.29
3.40
4.20
A++
3.50
6.35
193
A++
3.32
4.90
949
3.58 / 3.5
A/B
475
12.5 / 8.7
204 (264)
840 (950)
840 (950)
18 (23.4)
31 / 27
49
4.89
3.26
5.00
6.00
A++
5.00
6.48
270
A++
4.36
4.29
1426
3.55 / 3.7
A/A
705
12.6 / 8.7
204 (264)
840 (950)
840 (950)
19 (24.4)
31 / 27
49
5.57
3.67
5.70
7.00
A++
5.70
6.22
321
A+
4.71
4.00
1646
3.48 / 3.52
A/B
820
13.6 / 8.7
204 (264)
840 (950)
840 (950)
19 (24.4)
33 / 28
51
RXS35L
RXS50L
RXS60L
550 x 765 x 285
34
735 x 825 x 300
47
1ph
6.30
6.80
20
735 x 825 x 300
48
4.00
4.30
10
3+E / 1.5
1/4 / 3/8
20
15
10
20
1.2
48
61
£718.00
£552.00
£1,270.00
7.40
9.40
20
3+E / 2.5
1/4 / 1/2
30
20
10
20
1.7
48
62
1/4 / 1/2
30
20
10
20
1.5
49
62
£735.00
£694.00
£1,429.00
£782.00
£740.00
£1,522.00
Accessories:
Notes:
Accessory Ref
Description
Trade Price
BRC7FA532F
BYCQ140DG
BYCQ140DW
BRYQ140A
KDBHQ55B140
KDDQ55B140 1&2
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
UK.CWB90-2
UK.DT1
UK.CGM
Wireless remote controller
Roundflow cassette decoration panel with self cleaning filter
Roundflow cassette decoration panel - white with white louvres
Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions
Sealing member for air discharge outlet
Fresh air intake kit for up to 20% fresh air - 2 part kit
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Condensing unit bracket - up to size 71
Condensate drip tray for use with UK.CWB90-2
Condensing Unit Guard size 42-71
£152.00
£310.00
£160.00
£99.00
£90.00
£249.00
£92.00
£190.00
£235.00
£251.00
£185.00
£47.00
£89.00
£93.00
£37.00
£56.00
£296.00
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)BRC7FA532F Trade price will be reduced
by £76.00 if ordered in place of the
BRC1E52A
iii)All fan coil units standard with auto restart
after power failure
iv)All fan coils suppled as standard with
BYCQ140D Decoration panel
v)BYCQ140DW / BYCQ140DG Trade prices
will be reduced by £142.00 if ordered in
place of standard decoration panel
vi)Minimum ambient operating
temperatures:
RXS
Features:
• FCQG is a compact cassette designed to suit installation in narrower ceiling voids
• The unique 360° radial air pattern ensures uniform air flow and temperature distribution
• Air flow flexibility: a wide selection of 23 different air flow patterns accessible via remote controller
• Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels
•Optional Self Cleaning Filter: The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost
• Suitable for Twin, Triple and Double Twin applications
• Re-use of existing R22 and R407C piping possible
• DIII net compatibility as standard
28
Residential, Commercial and Industrial
Cooling
Heating
-10°C
-15°C
SPLIT, SKY AIR HEAT PUMPS
4-Way Blow Cassette – Inverter
ACQ-B/AZQS
Indoor Units
Single Phase
Capacity
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
COOLING
SEER
Annual Energy Consumption
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
HEATING
SCOP
Annual Energy Consumption
Nominal Efficiency
EER / COP
Energy Label
Annual Energy Consumption
Air Flow Rate
High / Low
Dimensions
Height
(with Decoration Panel) Width
Depth
Weight (with Decoration Panel)
Sound Pressure
High / Low
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
3 Phase
ACQ71C
ACQ100C
ACQ125C
ACQ100C
ACQ125C
7.28
4.99
6.80
7.50
B
6.33
4.65
476
A
6.33
3.80
2332
3.31/3.61
A/A
1027
24.4 / 17.6
265 (347)
820 (990)
820 (990)
31 (35)
41 / 35
50
10.80
7.44
9.50
10.80
B
9.50
4.65
716
A
7.60
3.80
2800
3.21/3.61
A/A
1480
29.2 / 21.0
300 (382)
820 (990)
820 (990)
39 (43)
44 / 38
54
13.60
9.30
12.10
13.50
3.01/3.41
2010
34.0 / 26.3
300 (382)
820 (990)
820 (990)
39 (43)
47 / 43
56
10.80
7.44
9.50
10.80
B
9.50
4.65
716
A
7.60
3.80
2800.00
3.21/3.61
A/A
1480.00
29.2 / 21.0
300 (382)
820 (990)
820 (990)
39 (43)
44 / 38
54.00
13.60
9.30
12.10
13.50
3.01/3.41
2010.00
34.0 / 26.3
300 (382)
820 (990)
820 (990)
39 (43)
47 / 43
56.00
AZQS71BV1
AZQS100BV1
AZQS120BV1
AZQS100BY1
770X900X320
67
990X940X320
81
48
64
1~
12.10
4
32
3+E / 1.5
3/8 / 5/8
50
15
30
Databook
Databook
53
70
£644.00
£857.00
£1,501.00
£749.00
£1,019.00
£1,768.00
8.38
4
20
3/8 / 5/8
30
15
30
16.43
4
32
4.02
4
20
3/8 / 5/8
50
15
30
3/8 / 5/8
50
15
30
5.46
4
20
3+E / 1.5
3/8 / 5/8
50
15
30
Databook
Databook
54
71
53
70
54
71
£836.00
£1,122.00
£1,958.00
£749.00
£1,067.00
£1,816.00
£836.00
£1,174.00
£2,010.00
Accessories:
Notes:
Accessory Ref
Description
Trade Price
R04084124324
UK.CWB90-2
UK.CWB140-2
UK.DT1
UK.DT2
UK.CGM
UK.CGL
PCB Adaptor for group control (1 per fan-coil)
Condensing unit bracket - up to size 71
Condensing unit bracket - sizes 100 to 140
Condensate drip tray for use with UK.CWB90-2
Condensate drip tray for use with UK.CWB140-2
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
£82.00
£37.00
£46.00
£56.00
£59.00
£296.00
£354.00
Features:
•
•
•
•
•
•
AZQS125BY1
990X940X320
82
3~
4-way blow cassette
Hard wired remote ARCWB as standard
7 day timer
Knock out for connection to branch duct
Auto swing mode for better air distribution
Suitable for rooms with suspended ceilings
i)Fan-coils supplied with both ARCWB hard
wired remote & infra-red remote
ii)Replacement Technology not applicable
to AZQS
iii)All fan coils suppled as standard with
ADP125A Decoration panel
iv)All fan coil units standard with auto restart
after power failure
v)Minimum ambient operating
temperature:
AZQS
Cooling
Heating
-5°C
-15°C
Price List 2014
29
SPLIT, SKY AIR HEAT PUMPS
Under Ceiling Cassette –
Seasonal Smart Inverter FUQ-C / RZQG
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
3 Phase
FUQ71C
FUQ100C
FUQ125C
FUQ71C
FUQ100C
FUQ125C
7.76
5.32
6.80
7.50
A++
6.80
6.50
366
A+
7.60
4.20
2533
4.07 / 4.47
A/A
840
23 / 16
198
950
950
25
41 / 35
59
10.80
7.44
9.50
10.80
A++
9.50
6.11
544
A+
11.30
4.50
3517
4.08 / 4.04
A/A
1230
31 / 20
198
950
950
26
46 / 39
64
13.60
9.30
12.00
13.50
A+
12.00
5.61
748
A+
14.13
4.44
4456
3.4 / 4.04
A/A
1770
32.5 / 20.5
198
950
950
26
47 / 40
65
7.76
5.32
6.80
7.50
A++
6.80
6.50
366
A+
7.60
4.20
2533
4.07 / 4.47
A/A
840
23 / 16
198
950
950
25
41 / 35
59
10.80
7.44
9.50
10.80
A++
9.50
6.11
544
A+
11.30
4.50
3515
4.08 / 4.04
A/A
1230
31 / 20
198
950
950
26
46 / 39
64
13.60
9.30
12.00
13.50
A+
12.00
5.61
748
A+
14.13
4.44
4456
3.4 / 4.04
A/A
1770
32.5 / 20.5
198
950
950
26
47 / 40
65
RZQG71L8V1
RZQG100L8V1
RZQG125L8V1
RZQG71L8Y1
RZQG100L8Y1
RZQG125L8Y1
990 x 940 x 320
78
1430 x 940 x 320
102
2.9
48
64
1ph
9.52
4
32
3+E / 1.5
3/8 / 5/8
75
30
30
Refer to Installation Manual
4.0
50
66
£915.00
£1,191.00
£2,106.00
£1,004.00
£1,514.00
£2,518.00
6.83
4
20
3/8 / 5/8
50
30
30
990 x 940 x 320
80
14.06
4
32
2.57
4
16
3/8 / 5/8
75
30
30
3/8 / 5/8
50
30
30
4.0
51
67
2.9
48
64
3ph
3.58
4
20
3+E / 1.5
3/8 / 5/8
75
30
30
Refer to Installation Manual
4.0
50
66
£1,109.00
£1,666.00
£2,775.00
£915.00
£1,227.00
£2,142.00
£1,004.00
£1,584.00
£2,588.00
Accessories:
5.29
4
20
3/8 / 5/8
75
30
30
4.0
51
67
£1,109.00
£1,743.00
£2,852.00
Notes:
Accessory Ref
Description
Trade Price
BRC7C58
EKRORO5
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
UK.CWB90-2
UK.CWB140-2
UK.DT1
UK.DT2
UK.CGM
UK.CGL
Wireless remote controller
Remote on/off control interface kit
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Condensing unit bracket - up to size 71
Condensing unit bracket - sizes 100 to 140
Condensate drip tray for use with UK.CWB90-2
Condensate drip tray for use with UK.CWB140-2
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
£152.00
£29.00
£92.00
£190.00
£235.00
£251.00
£185.00
£47.00
£89.00
£93.00
£37.00
£46.00
£56.00
£59.00
£296.00
£354.00
Features:
• The 4-way blow under ceiling cassettes are the ideal solution for rooms, shops or offices without false ceilings
• Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology
•Air flow flexibility: air can be discharged in any of 4 directions. Possibility to shut off 1 or 2 flaps enabling the unit
to be installed in a corner or small room
• 3 step fan-speed
• Suitable for Twin, Triple and Double Twin applications
• Re-use of existing R22 and R407C piping possible
• Comms, computer and server room cooling possible with EDP setting
• Selectable evaporating & condensing temperature for greater operating efficiency
30
1430 x 940 x 320
101
Residential, Commercial and Industrial
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)BRC7C58 Trade price will be reduced
by £76.00 if ordered in place of the
BRC1E52A
iii)All fan coil units standard with auto restart
after power failure
iv)Minimum ambient operating
temperatures:
RZQG
Cooling
Heating
-15°C
-20°C
SPLIT, SKY AIR HEAT PUMPS
Built in DC Ducted & Slim Ducted –
Inverter FBQ & FDXS-F / RXS
Indoor Units
DC Ducted
Capacity
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
FBQ50C8
FBQ60C8
FDXS25F
FDXS35F
FDXS50F9
FDXS60F
3.32
2.93
3.50
4.00
A+
3.50
5.97
205
A+
2.90
3.93
1033
3.21 / 3.6
A/A
530
16 / 11
300
700
700
25
32 / 27
50
4.89
3.60
5.90
5.50
A+
4.90
5.85
293
A
4.35
3.85
1584
3.03 / 3.42
B/B
825
16 / 11
300
700
700
25
37 / 29
55
5.57
4.10
5.70
7.00
A+
5.70
5.72
349
A
4.60
3.80
1693
3.26 / 3.41
A/B
875
18 / 15
300
1000
700
34
37 / 30
55
2.35
1.81
2.40
3.20
A+
2.40
5.63
149
A+
2.60
4.24
858
3.69 / 4
A/A
325
8.7 / 7.3
200
700
620
21
35 / 31
53
3.32
2.26
3.40
4.00
A
3.40
5.21
228
A
2.90
3.88
1047
3.21 / 3.48
A/B
530
8.7 / 7.3
200
700
620
21
35 / 31
53
4.81
3.08
5.00
5.80
A+
5.00
5.72
306
A
4.00
3.93
1425
3.03 / 3.1
B/D
825
12 / 10
200
1150
620
30
37 / 33
55
5.86
3.97
6.00
7.00
A
6.00
5.51
381
A
4.60
3.80
1693
2.91 / 3.21
C/C
1030
16 / 13.5
200
1100
620
30
38 / 34
56
RXS50L
RXS60L
RXS25L
RXS35L
RXS50L
RXS60L
Outdoor Units
RXS35L
Dimensions
Weight
Electrical Details
Height x Width x Depth
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
Slim Ducted
FBQ35C8
550 x 765 x 285
34
1ph - see notes
4.6*
4.3
10
3+E / 1.5
1/4 / 3/8
20
15
10
1.2
48
61
£547.00
£552.00
£1,099.00
735 x 825 x 300 735 x 825 x 300
47
48
1ph
7.2*
9.2*
6.8
9.4
20
20
3+E / 2.5
1/4 / 1/2
1/4 / 1/2
30
30
20
20
10
10
20
1.7
1.5
48
49
62
62
£575.00
£694.00
£1,269.00
550 x 765 x 285
34
550 x 765 x 285 735 x 825 x 300 735 x 825 x 300
34
47
48
1ph
3.90
4.90
7.10
9.20
3.3
4.3
6.8
9.4
10
10
20
20
3+E / 1.5
3+E / 2.5
1/4 / 3/8
1/4 / 3/8
1/4 / 1/2
1/4 / 1/2
20
20
30
30
15
15
20
20
10
10
10
10
20
1.0
1.2
1.7
1.5
46
48
48
49
59
61
62
62
£639.00
£740.00
£1,379.00
£394.00
£476.00
£870.00
Accessories:
£441.00
£552.00
£993.00
£477.00
£694.00
£1,171.00
£524.00
£740.00
£1,264.00
Notes:
Accessory Ref
Description
Applicable Units
Trade Price
BRC4C65
BRC2C51
EKRORO3
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
BYBS45D
BYBS71D
UK.RAC2
UK.RAC3
UK.RAC3A
UK.RAC5
UK.RAC6
UK.RAC7
UK.SAF2
UK.SAF3
UK.SAF3A
UK.SAF5
UK.SAF6
UK.SAF7
UK.CWB90-2
UK.DT1
UK.CGS
UK.CGM
Wireless remote controller
Wired Simplified remote controller (without auto swing)
Remote on/off control interface kit
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air & VRV. Duty rotation, Lead Lag control & heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Return air suction grille
Return air suction grille
Return Air Chamber, 2 x 200mm dia
Return Air Chamber, 2 x 200mm dia
Return Air Chamber, 3 x 200mm dia
Return Air Chamber, 2 x 150mm dia
Return Air Chamber, 3 x 150mm dia
Return Air Chamber, 4 x 150mm dia
Supply Air Flange 2 x 200mm dia
Supply Air Flange 2 x 200mm dia
Supply Air Flange 3 x 200mm dia
Supply Air Flange 2 x 150mm dia
Supply Air Flange 3 x 150mm dia
Supply Air Flange 4 x 150mm dia
Condensing unit bracket - up to size 71
Condensate drip tray for use with UK.CWB90-2
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
FBQ / FDXS
FBQ / FDXS
FBQ
FBQ / FDXS
FBQ / FDXS
FBQ / FDXS
FBQ / FDXS
FBQ / FDXS
FBQ / FDXS
FBQ / FDXS
FBQ / FDXS
FBQ35~50
FBQ60
FBQ35~50
FBQ60
FBQ60
FDXS25~35
FDXS50
FDXS60~71
FBQ35~50
FBQ60
FBQ60
FDXS25~35
FDXS50
FDXS60~71
£152.00
£90.00
£29.00
£92.00
£190.00
£235.00
£251.00
£185.00
£47.00
£89.00
£93.00
£121.00
£159.00
£79.00
£86.00
£93.00
£76.00
£83.00
£97.00
£72.00
£79.00
£84.00
£67.00
£73.00
£85.00
£37.00
£56.00
£214.00
£296.00
i)FBQ & FDXS fan coils supplied as standard
with BRC1E52A wired remote controller
with 7-day time clock
ii)BRC4C65 Trade price will be reduced
by £76.00 if ordered in place of the
BRC1E52A
iii)All fan coil units standard with auto restart
after power failure
iv)All fan coils supplied as standard with
air filter
v)Minimum ambient operating
temperatures:
RXS
Cooling
Heating
-10°C
-15°C
vi)FBQ35C8 Fan Coil unit requires a
separate 1ph 5 amp power supply
Features:
• Fan speed: 5 fan speeds can be selected, high to super low
• Connection to multi outdoor possible
• Re-use of existing R22 and R407C piping possible
Price List 2014
31
SPLIT, SKY AIR HEAT PUMPS
Built in DC Ducted –
Seasonal Smart Inverter FBQ / RZQG
Indoor Units
Single Phase
Capacity
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
3 Phase
FBQ71C8
FBQ100C8
FBQ125C8
FBQ140C8
FBQ71C8
FBQ100C8
FBQ125C8
FBQ140C8
7.76
5.32
6.80
7.50
A++
6.80
6.11
389
A+
6.00
4.01
2094
3.5 / 3.65
A/A
970
18 / 15
300
1000
700
34
37 / 29
57
10.80
7.44
9.50
10.80
A+
9.50
5.80
573
A++
11.30
4.61
3431
3.89 / 4.21
A/A
1220
32 / 23
300
1400
700
45
38 / 32
61
13.60
9.30
12.00
13.50
A+
12.00
5.81
722
A+
12.71
4.21
4226
3.81 / 3.83
A/A
1575
39 / 28
300
1400
700
45
40 / 33
66
14.90
10.25
13.40
15.50
3.33 / 3.61
A/A
2010
39 / 28
300
1400
700
45
40 / 33
66
7.76
5.32
6.80
7.50
A++
6.80
6.11
389
A+
6.00
4.01
2094
3.5 / 3.65
A/A
970
18 / 15
300
1000
700
34
37 / 29
57
10.80
7.44
9.50
10.80
A+
9.50
5.80
573
A++
11.30
4.61
3431
3.89 / 4.21
A/A
1220
32 / 23
300
1400
700
45
38 / 32
61
13.60
9.30
12.00
13.50
A+
12.00
5.81
722
A+
12.71
4.21
4226
3.81 / 3.83
A/A
1575
39 / 28
300
1400
700
45
40 / 33
66
14.90
10.25
13.40
15.50
3.33 / 3.61
A/A
2010
39 / 28
300
1400
700
45
40 / 33
66
RZQG71L8V1 RZQG100L8V1 RZQG125L8V1 RZQG140L7V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1
Dimensions
Weight
Electrical Details
Height x Width x Depth
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
990 x 940 x 320
78
7.93
4
20
3/8 / 5/8
50
30
30
2.9
48
64
£918.00
£1,191.00
£2,109.00
1430 x 940 x 320
102
1ph
9.97
12.87
4
4
32
32
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
75
75
30
30
30
30
Refer to Installation Manual
4.0
4.0
50
51
66
67
£960.00
£1,514.00
£2,474.00
£1,137.00
£1,666.00
£2,803.00
990 x 940 x 320
80
16.43
4
32
2.98
4
16
3/8 / 5/8
75
30
30
3/8 / 5/8
50
30
30
4.0
52
69
2.9
48
64
£1,318.00
£1,901.00
£3,219.00
£918.00
£1,227.00
£2,145.00
Accessories:
Accessory Ref
Description
BRC4C65
EKRORO3
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
BYBS71D
BYBS125D
EKBYBSD
UK.RAC3
UK.RAC3A
UK.RAC4
UK.SAF3
UK.SAF3A
UK.SAF4
UK.CWB90-2
UK.CWB140-2
UK.DT1
UK.DT2
UK.CGM
UK.CGL
Wireless remote controller
Remote on/off control interface kit
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock.
Energy control PCB for Sky Air and VRV.
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Return air suction grille
Return air suction grille
Mounting Kit for Decoration Panel (when installed directly onto the unit body)
Return Air Chamber, 2 x 200mm dia
Return Air Chamber, 3 x 200mm dia
Return Air Chamber, 4 x 200mm dia
Supply Air Flange 2 x 200mm dia
Supply Air Flange 3 x 200mm dia
Supply Air Flange 4 x 200mm dia
Condensing unit bracket - up to size 71
Condensing unit bracket - sizes 100 to 140
Condensate drip tray for use with UK.CWB90-2
Condensate drip tray for use with UK.CWB140-2
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
1430 x 940 x 320
101
3ph
3.75
4.84
4
4
20
20
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
75
75
30
30
30
30
Refer to Installation Manual
4.0
4.0
50
51
66
67
£960.00
£1,584.00
£2,544.00
£1,137.00
£1,743.00
£2,880.00
6.18
4
20
3/8 / 5/8
75
30
30
4.0
52
69
£1,318.00
£2,002.00
£3,320.00
Notes:
Applicable Units
FBQ71
FBQ100~140
FBQ71
FBQ71
FBQ100~140
FBQ71
FBQ71
FBQ100~140
Trade Price
£152.00
£29.00
£92.00
£190.00
£235.00
£251.00
£185.00
£47.00
£89.00
£93.00
£159.00
£198.00
£28.00
£86.00
£93.00
£116.00
£79.00
£84.00
£104.00
£37.00
£46.00
£56.00
£59.00
£296.00
£354.00
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)BRC4C65 Trade price will be reduced
by £76.00 if ordered in place of the
BRC1E52A
iii)All fan coil units standard with auto restart
after power failure
iv)All fan coils supplied as standard with
air filter
v)Minimum ambient operating
temperatures:
RZQG
RZQSG
Cooling
Heating
-15°C
-15°C
-20°C
-15°C
Features:
• The new inverter fan ducted units, provides both drastic energy savings and simplifies installation
• Automatically adjusts air volume against ESP at commissioning
• Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology
• Comms, computer and server room cooling possible with EDP setting
•Selectable evaporating & condensing temperature for greater operating efficiency
32
Residential, Commercial and Industrial
•
•
•
•
Fan speed: 2 fan speeds can be selected, high or low
Suitable for Twin, Triple and Double Twin applications
Re-use of existing R22 and R407C piping possible
DIII net compatibility as standard
SPLIT, SKY AIR HEAT PUMPS
Built in DC Ducted –
Seasonal Classic Inverter FBQ / RZQSG
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
3 Phase
FBQ71C8
FBQ100C8
FBQ125C8
FBQ140C8
FBQ100C8
FBQ125C8
FBQ140C8
7.28
4.99
6.80
7.50
A+
6.80
5.81
410
A
6.00
3.88
2166
3.28 / 3.61
A/A
1037
18 / 15
300
1000
700
34
37 / 29
57
10.80
7.44
9.50
10.80
A
9.50
5.50
604
A+
7.60
4.01
2653
3.31 / 3.65
A/A
1435
32 / 23
300
1400
700
45
38 / 32
61
13.60
9.30
12.00
13.50
A
12.00
5.20
807
A
7.60
3.90
2728
3.21 / 3.51
A/B
1870
39 / 28
300
1400
700
45
40 / 33
66
14.90
10.25
13.40
15.50
3.02 / 3.41
B/B
2220
39 / 28
300
1400
700
45
41 / 34
66
10.80
7.44
9.50
10.80
A
9.50
5.50
604
A+
7.60
4.01
2653
3.31 / 3.65
A/A
1435
32 / 23
300
1400
700
45
38 / 32
61
13.60
9.30
12.00
13.50
A
12.00
5.20
807
A
7.60
3.90
2728
3.21 / 3.51
A/B
1870
39 / 28
300
1400
700
45
40 / 33
66
14.90
10.25
13.40
15.50
3.02 / 3.41
B/B
2220
39 / 28
300
1400
700
45
41 / 34
66
RZQSG71L3V1 RZQSG100L8V1 RZQSG125L8V1 RZQSG140LV1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
770 x 900 x 320
67
8.46
4
20
3/8 / 5/8
50
30
30
2.75
49
65
£918.00
£881.00
£1,799.00
990 x 940 x 320
81
1ph
11.73
15.29
4
4
32
32
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
50
50
30
30
30
30
Refer to Installation Manual
2.9
2.9
53
54
69
70
£960.00
£1,220.00
£2,180.00
£1,137.00
£1,338.00
£2,475.00
1430 x 940 x 320
102
18.15
4
32
3/8 / 5/8
50
30
30
4.0
53
69
£1,318.00
£1,490.00
£2,808.00
990 x 940 x 320
1430 x 940 x 320
82
101
3ph
4.39
5.72
6.79
4
4
4
20
20
20
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
3/8 / 5/8
50
50
50
30
30
30
30
30
30
Refer to Installation Manual
2.9
2.9
4.0
53
54
53
69
70
69
£960.00
£1,257.00
£2,217.00
£1,137.00
£1,378.00
£2,515.00
£1,318.00
£1,535.00
£2,853.00
Price List 2014
33
SPLIT, SKY AIR HEAT PUMPS
Concealed Ceiling Unit
ABQ-B/A / AZQS
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
3 Phase
ABQ71B
ABQ100A
ABQ125A
ABQ140A
ABQ100A
ABQ125A
ABQ140A
7.28
4.99
6.80
7.50
B
6.80
4.65
512
A
6.33
3.41
2599
3.01 / 3.61
B/A
1130
18.3 / 15.6
285
1007
600
35
TBC
59
10.80
7.44
9.50
10.80
3.05 / 3.55
B/B
tbc
tbc
305
1325
638
47
51 / 45
73
13.60
9.30
12.10
13.50
2.91 / 3.41
C/B
2079
TBC
378
1388
541
50
52 / 47
73
14.90
10.25
13.00
15.50
3.01 / 3.41
B/B
2159
TBC
378
1388
541
56
53 / 47
75
10.80
7.44
9.50
10.80
3.05 / 3.55
B/B
tbc
tbc
305.00
1325.00
638.00
47.00
51 / 45
73.00
13.60
9.30
12.10
13.50
2.91 / 3.41
C/B
2079.00
TBC
378.00
1388.00
541.00
50.00
52 / 47
73.00
14.90
10.25
13.00
15.50
3.01 / 3.41
B/B
2159.00
TBC
378.00
1388.00
541.00
56.00
53 / 47
75.00
AZQS71BV1
AZQS100BV1
AZQS125BV1
AZQS140BV1
AZQS100BY1
AZQS125BY1
770x900x320
67
data-book
48
64
990x940x320
81
1~
tbc
17.00
4
4
32
32
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
50
50
30
30
30
30
data-book
data-book
data-book
53
54
70
71
£632.00
£857.00
£1,480.00
£812.00
£1,019.00
£1,831.00
9.24
4
20
3/8 / 5/8
30
15
30
£926.00
£1,122.00
£2,048.00
1430x940x320
102
data-book
53
70
data-book
53
70
£812.00
£1,067.00
£1,879.00
£926.00
£1,174.00
£2,100.00
£969.00
£1,347.00
£2,316.00
tbc
4
20
3/8 / 5/8
50
30
30
3/8 / 5/8
50
30
30
data-book
53
70
£969.00
£1,280.00
£2,249.00
4.32
4
20
3/8 / 5/8
50
30
30
Notes:
Accessory Ref
Description
Trade Price
R04084124324
UK.CWB90-2
UK.CWB140-2
UK.DT1
UK.DT2
UK.CGM
UK.CGL
PCB Adaptor for group control (1 per fan-coil)
Condensing unit bracket - up to size 71
Condensing unit bracket - sizes 100 to 140
Condensate drip tray for use with UK.CWB90-2
Condensate drip tray for use with UK.CWB140-2
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
£82.00
£37.00
£46.00
£56.00
£59.00
£296.00
£354.00
Features:
7 day timer as standard
Hard wired remote ARCWA as standard
Ideal for shops / restaurants with ceiling voids
High external static pressures for long duct runs
34
AZQS140BY1
1430x940x320
101
3~
4.16
4
20
3+E / 1.5
3/8 / 5/8
50
30
30
data-book
data-book
54
71
17.66
4
32
Accessories:
•
•
•
•
990x940x320
81
Residential, Commercial and Industrial
i)Fan-coils supplied with ARCWA hard
wired remote
iiReplacement Technology not applicable
to AZQS
iii)All fan coil units standard with auto restart
after power failure
iv)Fan-coils supplied as standard with
air filter
v)Minimum ambient operating
temperature:
AZQS
Cooling
Heating
-5°C
-15°C
SPLIT, SKY AIR HEAT PUMPS
High Static Ducted – Seasonal Smart,
Classic & Super Inverter FDQ
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
Single Phase
3 Phase
Single Phase
3 Phase
FDQ125C
FDQ125C
FDQ125C
FDQ125C
FDQ200B
FDQ250B
13.60
9.30
12.00
13.50
A+
12.00
5.81
722
A+
12.71
4.21
4226
3.75 / 3.83
A/A
1600
39 / 28
300
1400
700
45
40 / 33
66
13.60
9.30
12.00
13.50
A+
12.00
5.81
722
A+
12.71
4.21
4226
3.75 / 3.83
A/A
1600
39 / 28
300
1400
700
45
40 / 33
66
13.60
9.30
12.00
13.50
A
12.00
5.20
807
A
7.60
3.90
2728
3.21 / 3.51
A/B
1870
39 / 28
300
1400
700
45
40 / 33
66
13.60
9.30
12.00
13.50
A
12.00
5.20
807
A
7.60
3.90
2728
3.21 / 3.51
A/B
1600
39 / 28
300
1400
700
45
40 / 33
66
19.40
16.30
20.00
23.00
3.21 / 3.41
A/B
3115
69 / 69
450
1400
900
89
45 / 45
81
23.50
20.70
25.00
27.00
2.81 / 3.21
C/C
4290
89 / 89
450
1400
900
94
47 / 47
82
RZQG125L8V1
RZQG125L8Y1
RZQSG125L8V1
RZQSG125L8Y1
RZQ200C
RZQ250C
1430 x 940 x 320
102
1ph - see notes
14.80
4
32
1430 x 940 x 320
990 x 940 x 320
101
81
3ph - see notes
1ph - see notes
4.89
17.30
4
4
20
32
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
75
50
30
30
30
30
Refer to Installation Manual
4.0
2.9
51
54
67
70
3/8 / 5/8
75
30
30
4.0
51
67
£1,244.00
£1,666.00
£2,910.00
£1,244.00
£1,743.00
£2,987.00
£1,244.00
£1,338.00
£2,582.00
990 x 940 x 320
82
3ph - see notes
5.72
4
20
3/8 / 5/8
50
30
30
2.9
54
70
£1,244.00
£1,378.00
£2,622.00
Accessories:
1680 x 930 x 765
1680 x 930 x 765
183
184
3ph - see notes
4.61
6.35
4
4
25
25
3+E / 1.5
3/8 / 7/8
1/2 / 7/8
100
100
30
30
30
30
Refer to Installation Manual
8.3
9.3
57
57
78
78
£1,561.00
£2,576.00
£4,137.00
£1,912.00
£2,698.00
£4,610.00
Notes:
Accessory Ref
Description
Trade Price
BRC4C65
EKRORO3
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KRCS01-4
KLIC-DI
DTA112B51
UK.CWB140-2
UK.DT2
UK.CGL
Wireless remote controller
Remote on/off control interface kit
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
Energy control PCB for Sky Air and VRV
Remote room mounted temperature sensor
KNX Interface for Sky Air and VRV systems
Adaptor PCB for interface to Daikin centralised control systems
Condensing unit bracket - sizes 100 to 140
Condensate drip tray for use with UK.CWB140-2
Condensing Unit Guard size 100-140 including RXYSQ
£152.00
£29.00
£92.00
£190.00
£235.00
£251.00
£47.00
£185.00
£89.00
£46.00
£59.00
£354.00
Features:
•
•
•
•
•
•
Super Inverter (3 phase)
High static units for longer ducted runs
Up to 200Pa External Static Pressure
Auto balancing air flow / ESP on commissioning
Comms, computer and server room cooling possible (Seasonal Smart only)
Super inverter technology: reduces power consumption by up to 70% compared to non inverter units
Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart only)
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)BRC4C65 Trade price will be reduced
by £76.00 if ordered in place of the
BRC1E52A
iii)Replacement technology not applicable
to RZQ200 and RZQ250
iv)All fan coil units standard with auto restart
after power failure
v)All fan coils supplied as standard with
air filter
vi)Minimum ambient operating
temperatures:
RZQG
RZQSG
RZQ
Cooling
Heating
-15°C
-15°C
-5°C
-20°C
-15°C
-15°C
vii)FDQ Fan Coil unit requires a separate
15 amp power supply
Price List 2014
35
SPLIT, SKY AIR HEAT PUMPS
Multi Series
Multi Series Inverters offer the ability to connect up to 5 fan coils to one
outdoor unit. With the MXS range it is possible to install indoor units throughout a house or
small commercial premises and only use 1 outdoor unit. Each indoor unit will have it’s own controller
and will be able to operate in heating or cooling.
Heating & cooling
Connectable
Indoor Units
Wall mounted
FTXG-L
CTXS-K
Floor standing
FTXS-K
FTXS-G
FTX-JV
FVXG-K
FVXS-F
Flexi type
Round flow
cassette
Fully flat
cassette
FLXS-B(9)
FCQG-F
FFQ-C
Concealed ceiling
FDXS-F(9)
Ceiling
suspended
FDBQ-B/FBQ-C8
FHQ-C
20 25 35 50 15 35 20 25 35 42 50 60 71 20 25 35 25 35 50 25 35 50 25 35 50 60 35 50 60 25 35 50 60 25 35 50 60 25 35 50 60 35 50 60
2MXS40H
2MXS50H
3MXS40K
3MXS52E
3MXS68G
4MXS68F
4MXS80E
5MXS90E
Outdoor Unit
2MXS40H3V1B
2MXS50H3V1B
3MXS40K3V1B
3MXS52E4V1B
3MXS68G3V1B
4MXS68F3V1B
4MXS80E3V3B
5MXS90E3V3B
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Cooling Mode
Indoor Unit
2 x FTXS20K2V1B
2 x FTXS25K2V1B
2 x FTXS20K2V1B
2 x CTXS15K2V1B,
1 x FTXS20K2V1B
1 x CTXS15K2V1B,
2 x FTXS20K2V1B
2 x CTXS15K2V1B,
2 x FTXS20K2V1B
3 x CTXS15K2V1B,
1 x FTXS35K2V1B
2 x CTXS15K2V1B,
3 x FTXS20K2V1B
●
●
●
Heating Mode
SEER
Energy
efficiency
class
Annual energy
consumption
kWh/a
Design load
PDesign kW
SCOP
Energy
efficiency
class
Annual
electricity
consumption
kWh/a
Design load
PDesign at
-10°C kW
Declared
heating
capacity
at -10°C
Back up
heating
capacity
6.61
6.61
6.9
7.15
A++
A++
A++
A++
212
265
203
245
4.0
5.0
4.0
5.0
4.12
4.00
4.05
4.31
A+
A+
A+
A+
1029
1466
1641
1605
3.1
4.2
4.8
5.0
2.5
3.4
3.9
4.0
0.6
0.8
0.9
1.0
5.34
A
446
6.8
4.00
A+
1868
5.4
4.4
1.0
5.68
A+
420
6.8
4.15
A+
1953
5.8
4.7
1.1
6.16
A++
416
7.4
4.00
A+
2194
6.3
5.1
1.2
6.42
A++
424
7.8
4.19
A+
2161
6.5
5.3
1.2
For seasonal data in combination with other indoor units, please consult www.daikineurope.com/energylabel
Multi Split & Mini VRV Fan Coils
Emura Wall Mounted Fan Coil Units
Trade Fan Coil Unit Price
FTXG20LW FTXG25LW FTXG35LW FTXG50LW FTXG20LS FTXG25LS FTXG35LS FTXG50LS
£262.00
£276.00
£310.00
£473.00
£313.00
£329.00
£369.00
£565.00
Wall Mounted Fan Coil Units
Trade Fan Coil Unit Price
CTXS15K
£146.00
FTXS20K
£154.00
FTXS25K
£165.00
Wall Mounted Low Inverter Fan Coil Units
Trade Fan Coil Unit Price
FTX20JV
£123.00
FTX25JV
£136.00
FTX35JV
£154.00
Flexi Fan Coil Units
Trade Fan Coil Unit Price
FLXS25B
£376.00
FLXS35B9
£423.00
FLXS50B
£459.00
Nexura Floor Standing Fan Coil Units
Trade Fan Coil Unit Price
FVXG25K
£631.00
FVXG35K
£679.00
FVXG50K
£744.00
Floor Standing Fan Coil Units
Trade Fan Coil Unit Price
FVXS25F
£523.00
FVXS35F
£564.00
FVXS50F
£616.00
Compact Roundflow Cassette Fan Coil Units
Trade Fan Coil Unit Price
FCQG35F
£718.00
FCQG50F
£735.00
FCQG60F
£782.00
600 Sq 600 Sq 4-way blow Cassette Fan Coil Units
Trade Fan Coil Unit Price
FFQ25C
£663.00
FFQ35C
£727.00
FFQ50C
£802.00
Ceiling Suspended Fan Coil Units
Trade Fan Coil Unit Price
FHQ35C
£710.00
FHQ50C
£770.00
FHQ60C
£845.00
Ducted Fan Coil Units
Trade Fan Coil Unit Price
FDBQ25B
£424.00
FBQ35C8
£547.00
FBQ50C8
£575.00
FBQ60C8
£639.00
iv)FDXS fan coil units supplied as standard
with air filter
Slim Ducted Fan Coil Units
Trade Fan Coil Unit Price
FDXS25F
£394.00
FDXS35F
£441.00
FDXS50F9
£477.00
FDXS60F
£524.00
v)2MXS40-50H can only be used with
FTXG, FTXS, FTX, FDXS, FVXG, FVXS, FLXS
fan coil units
36
Residential, Commercial and Industrial
FTXS35K
£189.00
FTXS42K
£212.00
FTXS50K
£294.00
FTXS60G
£300.00
FTXS71G
£400.00
Notes:
FFQ60C
£849.00
i)Accessories for fan coils - refer to pair
system pages
ii)All fan coil units standard with auto restart
after power failure
iii)All fan coil units supplied as standard with
remote controller
Outdoor Units
Capacity
Dimensions
Weight
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Nominal Cooling
Nominal Heating
Height
Width
Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
High
Maximum Length
Maximum Vertical Rise
Piping Connections
Liquid
Gas
Number of Connected Indoor Units
2MXS40H
2MXS50H
3MXS40K
3MXS52E
3MXS68G
4MXS68F
4MXS80E
5MXS90E
4.00
4.40
550
765
285
38
5.00
5.70
550
765
285
42
4.00
4.60
735
936
300
49
5.20
6.80
735
936
300
49
6.80
8.60
735
936
300
58
6.80
8.60
735
936
300
58
8.00
9.60
770
900
320
72
9.00
10.40
770
900
320
73
4
20
4
20
kW
kW
mm
mm
mm
kg
Phase
Hz
V
amps
amps
amps
4
16
4
16
1.2
47
62
30
15
2x 1/4
2x 3/8
2
1.6
48
63
30
15
2x 1/4
3/8 1/2
2
£998.00
£1,104.00
kg
dBA
m
m
inches
inches
Trade Condensing Unit Price
1ph
50
230
Refer to Multi Combination Tables
4
4
4
4
16
20
20
20
R410a
2.0
2.0
2.6
2.6
46
46
48
48
59
59
61
61
50
50
60
60
15
15
15
15
3x 1/4
3x 1/4
3x 1/4
4x 1/4
2x3/8 1/2
2x3/8 1/2
3/8 2x1/2
2x3/8 2x1/2
3
3
3
4
£1,040.00
£1,156.00
£1,637.00
Accessories:
£1,766.00
3.0
3.0
48
52
62
66
70
75
15
15
4x 1/4
5x 1/4
3/8 1/2 2x5/8 2x3/8 1/2 2x5/8
4
5
£1,989.00
£2,141.00
Notes:
Accessory Ref
Description
Trade Price
UK.CWB90-2
UK.DT1
UK.CGM
Condensing unit bracket - up to size 71
Condensate drip tray for use with UK.CWB90-2
Condensing Unit Guard size 42-71
£37.00
£56.00
£296.00
i) Minimum ambient operating temperatures:
2MXS40, 50
3MXS40, 52, 68
4MXS68, 80
5MXS90
Cooling
Heating
10°C
-10°C
-10°C
-10°C
-15°C
-15°C
-15°C
-15°C
Please note: RXYSQ units are subject to VRV discount level
Mini VRV for Residential Applications
RXYSQ-P8
Outdoor Units
RXYSQ4P8V1
RXYSQ5P8V1
RXYSQ6P8V1
kW
kW
mm
mm
mm
kg
Phase
Hz
V
amps
amps
amps
12.60
14.20
1345
900
320
120
15.50
18.00
1345
900
320
120
kg
dBA
dBA
m
m
inches
inches
Capacity Index Limit
Number of Connected Indoor Units
4.0
50
66
115
data book
3/8
5/8
50~130
8
14.00
16.00
1345
900
320
120
1ph
50
230
Refer to Multi Combination Tables
4
32
R410a
4.0
51
67
135
data book
3/8
5/8
62.5~162.5
10
4.0
53
69
145
data book
3/8
3/4
70~182
13
Trade Condensing Unit Price
£2,735.00
£3,074.00
£3,431.00
Capacity
Dimensions
Weight
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
Height
Width
Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
High
High
Maximum Length
Maximum Vertical Rise
Liquid
Gas
4
32
Accessories:
4
32
Notes:
Accessory Ref
Description
Trade Price
BPMKS967A2
BPMKS967A3
KHRQ22M20T
Branch Provider Kit - 2 fan coil units
Branch Provider Kit - 3 fan coil units
R410a 2 Pipe Refnet Joint
£356.00
£380.00
£29.00
i) Minimum ambient operating temperatures:
RXYSQ-P8
Cooling
Heating
-5°C
-20°C
Price List 2014
37
SPLIT, SKY AIR HEAT PUMPS
Multi Series Inverters
MXS-E/F/G/H/K
SPLIT, SKY AIR HEAT PUMPS
Twin, Triple and Double Twin Outdoor Units
Possible Combinations
Outdoor Units
Nominal Cooling kW
Nominal Heating kW
6.80
6.80
9.50
9.50
9.50
9.50
12.00
12.00
12.00
12.00
12.00
12.00
13.40
13.40
13.40
13.40
13.40
13.40
19.50
19.50
19.50
19.50
25.00
25.00
7.50
7.50
10.80
10.80
10.80
10.80
13.50
13.50
13.50
13.50
13.50
13.50
15.50
15.50
15.50
15.50
15.50
15.50
23.40
23.40
23.40
23.40
27.00
27.00
RZQG71L8V1 / Y1
RZQSG71L3V1 / Y1
RZQG100L8V1 / Y1
RZQG100L8V1 / Y1
RZQSG100L8V1 / Y1
RZQSG100L8V1 / Y1
RZQG125L8V1 / Y1
RZQG125L8V1 / Y1
RZQG125L8V1 / Y1
RZQSG125L8V1 / Y1
RZQSG125L8V1 / Y1
RZQSG125L8V1 / Y1
RZQG140L7V1 / LY1
RZQG140L7V1 / LY1
RZQG140L7V1 / LY1
RZQSG140LV1 / LY1
RZQSG140LV1 / LY1
RZQSG140LV1 / LY1
RZQ200
RZQ200
RZQ200
RZQ200
RZQ250
RZQ250
Possible Combinations
35
35
50
35
50
35
60
50
35
60
50
35
71
50
35
71
50
35
100
60
71
50
125
60
+ 35
+ 35
+ 50
+ 35 +
+ 50
+ 35 +
+ 60
+ 50 +
+ 35 +
+ 60
+ 50 +
+ 35 +
+ 71
+ 50 +
+ 35 +
+ 71
+ 50 +
+ 35 +
+ 100
+ 60 +
+ 71 +
+ 50 +
+ 125
+ 60 +
35
35
50
35
+
35
50
35
+
35
50
35
+
35
50
35
+
35
60
71
50
+
50
60
+
60
Model Types
FFQ, FCQG, FBQ, FDXS, FHQ
FFQ, FCQG, FBQ, FDXS, FHQ
FFQ, FCQG, FBQ, FDXS, FHQ
FFQ, FCQG, FBQ, FDXS, FHQ
FFQ, FCQG, FBQ, FDXS, FHQ
FFQ, FCQG, FBQ, FDXS, FHQ
FFQ, FCQG, FBQ, FDXS, FHQ
FFQ, FCQG, FBQ, FDXS, FHQ
FFQ, FCQG, FBQ, FDXS, FHQ
FFQ, FCQG, FBQ, FDXS, FHQ
FFQ, FCQG, FBQ, FDXS, FHQ
FFQ, FCQG, FBQ, FDXS, FHQ
FCQG, FCQHG, FBQ, FHQ, FUQ, FAQ
FFQ, FCQG, FBQ, FDXS, FHQ
FFQ, FCQG, FBQ, FDXS, FHQ
FCQG, FCQHG, FBQ, FHQ, FUQ, FAQ
FFQ, FCQG, FBQ, FDXS, FHQ
FFQ, FCQG, FBQ, FDXS, FHQ
FCQG, FCQHG, FBQ, FHQG, FUQ, FAQ
FFQ, FCQG, FBQ, FDXS, FHQ
FCQG, FCQHG, FBQ, FHQ, FUQ, FAQ
FFQ, FCQG, FBQ, FDXS, FHQ
FCQG, FCQHG, FBQ, FHQ, FUQ, FDQ
FFQ, FCQG, FBQ, FDXS, FHQ
EXAMPLE:
TRADE EACH
TRADE TOTAL
Heat pump triple system using the following:
3 No FCQG71-F
Fan coil units
£829.00
£2,487.00
1 No RZQ200C
Condensing unit
£2,578.00
£2,578.00
1 No KHRQ250H7 Pipework branch kit
£81.00
£81.00
2 No BRC1E52A Remote controller (Credit)
-£76.00
-£152.00
TOTAL £4,994.00
Twin, Triple and Double Twin Outdoor Units
Fan Coils
Wall Mounted Fan Coil Units
Trade Fan Coil Unit Price
FAQ71C
£799.00
FAQ100C
£863.00
Ceiling Suspended Fan Coil Units
Trade Fan Coil Unit Price
FHQ35C
£710.00
FHQ50C
£770.00
FHQ60C
£845.00
FHQ71C
£989.00
FHQ100C
£1,051.00
Compact Roundflow Cassette Fan Coil Units
Trade Fan Coil Unit Price
FCQG35F
£718.00
FCQG50F
£735.00
FCQG60F
£782.00
FCQG71F
£829.00
FCQG100F FCQG125F
£940.00 £1,028.00
FBQ100C8 FBQ125C8
£960.00 £1,137.00
High COP Roundflow Cassette Fan Coil Units
Trade Fan Coil Unit Price
FCQHG71F FCQHG100F FCQHG125F
£829.00
£940.00 £1,028.00
600 Sq 4-way Blow Cassette Fan Coil Units
Trade Fan Coil Unit Price
FFQ35C
£727.00
FFQ50C
£802.00
FFQ60C
£849.00
Under Ceiling 4-way Blow Cassette Fan Coil Units
Trade Fan Coil Unit Price
FUQ71C
£915.00
FUQ100C
£1,004.00
FUQ125C
£1,109.00
DC Ducted Fan Coil Units
Trade Fan Coil Unit Price
FBQ35C8
£547.00
FBQ50C8
£575.00
FBQ60C8
£639.00
FBQ71C8
£918.00
Slim Ducted Fan Coil Units
Trade Fan Coil Unit Price
FDXS25F
£394.00
FDXS35F
£441.00
FDXS50F9
£477.00
FDXS60F
£524.00
High Static Ducted Fan Coil Units
Trade Fan Coil Unit Price
FDQ125C
£1,244.00
Notes:
i)Each of the fan coil units includes one remote controller BRC1E52A
ii)FBQ50C to 71C fan coil units require a separate 1 ph power supply when connected to RZQ200 and 250C
iii)Self cleaning deco-panel BYCQ140DG is compatible on cassettes used in twin, triple and double twin applications
iv)For seasonal data on Twin, Triple and Double Twin applications please consult www.daikineurope.com/energylabel
v)Accessories for fan coils and condensing units - refer to pair system pages
38
FHQ125C
£1,315.00
Residential, Commercial and Industrial
Notes:
These systems allow a mixture of fan coil
types and sizes on the same condensing unit.
Each system is operated on the Master and
Slave principle from one remote controller.
As the number of possible combinations is so
great, we are unable to show each system as
separate prices within the price list.
To calculate a system price please refer to
the next pages for individual fan coil and
condensing unit prices and remember to add
the pipework joints listed as accessory items
on the following pages.
Each fan coil unit includes within its price for
a remote controller. As a complete system
requires only one controller, you will need to
subtract the controller cost from all but one
fan coil on each system.
SPLIT, SKY AIR HEAT PUMPS
Seasonal Smart Inverter
RZQG
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height
Width
Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
mm
mm
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
Trade Condensing Unit Price
Seasonal Smart Inverter
Seasonal Smart Inverter
Single Phase
3 Phase
RZQG
71L8V1
990
940
320
78
RZQG
100L8V1
1430
940
320
102
RZQG
125L8V1
1430
940
320
102
RZQG
140L7V1
1430
940
320
102
RZQG71L8Y1
990
940
320
80
RZQG100L8Y1
1430
940
320
101
1ph
data book
RZQG125L8Y1
1430
940
320
101
RZQG140LY1
1430
940
320
101
RZQ200C
RZQ250C
1680
930
765
183
1680
930
765
184
3ph
data book
4
20
4
32
4
32
4
32
3/8 / 5/8
50
3/8 / 5/8
75
3/8 / 5/8
75
3/8 / 5/8
75
2.9
48
64
4.0
50
66
4.0
51
67
4.0
52
69
£1,191.00
£1,514.00
£1,666.00
£1,901.00
4
16
4
20
3ph
data book
4
20
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
3/8 / 5/8
50
75
75
30
30
Refer to Installation Manual
2.9
4.0
4.0
48
50
51
64
66
67
£1,227.00
£1,584.00
£1,743.00
4
20
4
25
4
25
3/8 / 5/8
75
3/8 / 7/8
100
1/2 / 7/8
100
4.0
52
69
8.3
57
78
9.3
57
78
£2,002.00
£2,576.00
£2,698.00
Notes:
Accessories:
Accessory Ref
KHRQ22M20T
KHRQ127H
KHRQ250H7
UK.CWB90-2
UK.CWB140-2
UK.DT1
UK.DT2
UK.CGM
UK.CGL
Super Inverter
Description
R410a 2 Pipe Refnet Joint
Triple Refnet Joint - RZQS71~140,RZQ100~140
Triple Refnet Joint - RZQ200~250
Condensing unit bracket - up to size 71
Condensing unit bracket - sizes 100 to 140
Condensate drip tray for use with UK.CWB90-2
Condensate drip tray for use with UK.CWB140-2
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
Trade Price
£29.00
£65.00
£81.00
£37.00
£46.00
£56.00
£59.00
£296.00
£354.00
i)Accessories for fan coils and condensing
units - refer to pair system pages
Seasonal Classic Inverter
RZQSG
Outdoor Units
Seasonal Classic Inverter
Seasonal Classic Inverter
Single Phase
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power Height
Width
Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Condensing Unit Price
mm
mm
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
RZQSG71L3V1
770
900
320
67
4
20
RZQSG100L8V1 RZQSG125L8V1
990
990
940
940
320
320
81
81
1ph
data book
4
4
32
32
3/8 / 5/8
50
3/8 / 5/8
50
2.75
49
65
2.9
53
69
£881.00
£1,220.00
3 Phase
RZQSG140LV1
1430
940
320
102
RZQSG100L8Y1
990
940
320
82
4
4
32
20
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
3/8 / 5/8
50
50
50
30
30
Refer to Installation Manual
2.9
4.0
2.9
54
53
53
70
69
69
£1,338.00
£1,490.00
£1,257.00
RZQSG140LY1
1430
940
320
101
3/8 / 5/8
50
3/8 / 5/8
50
2.9
54
70
4.0
53
69
£1,378.00
£1,535.00
4
20
Notes:
Accessories:
Accessory Ref
KHRQ22M20T
KHRQ127H
KHRQ250H7
UK.CWB90-2
UK.CWB140-2
UK.DT1
UK.DT2
UK.CGM
UK.CGL
RZQSG125L8Y1
990
940
320
82
3ph
data book
4
20
Description
R410a 2 Pipe Refnet Joint
Triple Refnet Joint - RZQS71~140,RZQ100~140
Triple Refnet Joint - RZQ200~250
Condensing unit bracket - up to size 71
Condensing unit bracket - sizes 100 to 140
Condensate drip tray for use with UK.CWB90-2
Condensate drip tray for use with UK.CWB140-2
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
Trade Price
£29.00
£65.00
£81.00
£37.00
£46.00
£56.00
£59.00
£296.00
£354.00
i)Accessories for fan coils and condensing
units - refer to pair system pages
Price List 2014
39
SPLIT, SKY AIR HEAT PUMPS
Air Curtains
Air curtains for light commercial applications
Biddle Standard air curtains are the ideal solution
for retailers and consultants to combat the issue
of climate separation across their outlet or
office doorway.
AIR ON
ATI
A
P
E
S RCIENC Y
I
F
F
E
U P TO
E
CK TIM
PAYBAS THAN
LES
Y
ENERGUP TO
S
G
SAVIN
1E.A5RS
72%
85%
Y
Biddle Standard air curtains are connected to selected Daikin
ERQ heat pump inverter condensing units offering:
Using a combination of rectifier technology, optimised air
velocity and temperature control they deliver greater comfort
to staff and customers alike, all year round, in all weathers.
• W
ide capacity range for maximum application potential plus
flexible control options
In conjunction with Biddle, Daikin now offer the best air
curtain to the market, coupling the benefits of the Biddle air
curtain technology with the benefits of the Daikin heat pump
inverter technology.
• R-410A refrigerant, single and 3 phase
• Wide operation range: -5~46°C in cooling and -20~15.5°C in heating
Small Air Curtains: Free Hanging, Cassette and Recessed
BIDDLE STANDARD AIR CURTAIN - SMALL
CYQS150DK80*BN
*=F
Heating Capacity
Delta T
Power Input (50Hz)
Maximum Door Width
Mounting Height *2
Dimensions
speed 3
speed 3
Inlet = room temperature
Fan only / Heating
Max / Min
Height
Width
Depth
Weight
Casing
Colour
Minimum requiring ceiling void
Fan - Air Flow Rate
Heating
Sound Pressure
Heating
Refrigerant
Type
Piping Connections
Liquid (OD) / Gas
Power Supply
speed 3
speed 3
kW
k
kW
m
m
mm
mm
mm
kg
270
1,500
590
66
mm
m3/sec
dBA
mm
ph/V/Hz
Trade Unit Price
*=C
9.00
15
0.35 / 0.35
1.50
2.3/2.0
270
1,500
821
83
white RAL9010
420
0.485
49
R-410A
9.52/16.0
1~/230/50
CYQS200DK100*BN
*=R
270
1,548
561
88
*=F
270
2,000
590
83
*=C
11.60
15
0.46 / 0.46
2.00
2.3/2.0
270
2,000
821
102
white RAL9010
420
0.647
50
R-410A
9.52/16.0
1~/230/50
CYQS250DK140*BN
*=R
270
2,048
561
108
*=F
270
2,500
590
107
*=C
*=R
16.20
16
0.58 / 0.58
2.50
2.3/2.0
270
2,500
821
129
white RAL9010
420
0.808
51
R-410A
9.52/19.0
1~/230/50
270
2,548
561
137
£3,635.00 £3,635.00 £3,831.00 £4,422.00 £4,422.00 £4,795.00 £4,964.00 £4,964.00 £5,373.00
F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air Outlet
Accessories:
Notes:
Accessory Ref
Description
Trade Price
BRC1E52A
KRCS01-1
RTD-20/UK.FB2
Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock
Remote room mounted temperature sensor
Energy control PCB for Sky Air and VRV
£76.00
£46.00
£251.00
Matching Air Cooled
Condensing Units
Trade Unit Price
CYQS150DK80*BN
CYQS200DK100*BN
CYQS250DK140*BN
40
Single Phase
ERQ100AV1
£1,533.00
•
•
Three Phase
ERQ125AV1
£1,709.00
ERQ140AV1
£2,049.00
ERQ125AW1
£1,743.00
ERQ200AW1
£3,271.00
•
•
•
•
•
Residential, Commercial and Industrial
ERQ250AW1
£3,408.00
i)Please refer to page 42 for ERQ features
and specifications
ii)To calculate the price for a complete
system, add together the prices of the
Air Curtain, ERQ condensing unit and
remote controller as below example:
1 No
CYQS150DK80FBN
£3,635.00
1 No
1 No
ERQ100AV1
BRC1E52A
£1,533.00
£76.00
TOTAL
£5,244.00
BIDDLE STANDARD AIR CURTAIN - MEDIUM
CYQM100DK80*BN
*=F
Heating Capacity
Delta T
Power Input (50Hz)
Maximum Door Width
Mounting Height *2
Dimensions
Inlet = room temperature
Fan only / Heating
speed 3
speed 3
Max / Min
Height
Width
Depth
Weight
Casing
Colour
Minimum requiring ceiling void
Fan - Air Flow Rate
Heating
Sound Pressure
Heating
Refrigerant
Type
Piping Connections
Liquid (OD) / Gas
Power Supply
speed 3
speed 3
kW
k
kW
m
m
mm
mm
mm
kg
*=R
9.20
17
0.37 / 0.37
1.00
2.5/2.3
270
270
270
1,000
1,000
1,048
590
821
561
57
68
66
white RAL9010
420
0.446
50
R-410A
9.52/16.0
1~/230/50
mm
m3/sec
dBA
mm
ph/V/Hz
Trade Unit Price
*=C
CYQM150DK80*BN
*=F
*=C
CYQM200DK100*BN
*=R
*=F
11.00
14
0.56 / 0.56
1.50
2.5/2.3
270
270
270
1,500
1,500
1,548
590
821
561
73
88
93
white RAL9010
420
0.669
51
R-410A
9.52/16.0
1~/230/50
*=C
*=R
13.40
13
0.75 / 0.75
2.00
2.5/2.3
270
270
270
2,000
2,000
2,048
590
821
561
94
111
117
white RAL9010
420
0.892
53
R-410A
9.52/16.0
1~/230/50
CYQM250DK140*BN
*=F
*=C
*=R
19.90
15
0.94 / 0.94
2.50
2.5/2.3
270
270
270
2,500
2,500
2,548
590
821
561
108
136
144
white RAL9010
420
1.115
54
R-410A
9.52/19.0
1~/230/50
£3,524.00 £3,524.00 £3,637.00 £4,199.00 £4,199.00 £4,393.00 £5,258.00 £5,258.00 £5,630.00 £6,020.00 £6,020.00 £6,421.00
F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air Outlet
Accessories:
Notes:
Accessory Ref
Description
Trade Price
BRC1E52A
KRCS01-1
RTD-20/UK.FB2
Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock
Remote room mounted temperature sensor
Energy control PCB for Sky Air and VRV
£76.00
£46.00
£251.00
Single Phase
Trade Unit Price
CYQM100DK80*BN
CYQM150DK80*BN
CYQM200DK100*BN
CYQM250DK140*BN
Three Phase
ERQ100AV1
ERQ125AV1
ERQ140AV1
ERQ125AW1
ERQ200AW1
ERQ250AW1
£1,533.00
•
•
•
£1,709.00
£2,049.00
£1,743.00
£3,271.00
£3,408.00
•
•
•
i)Please refer to page 42 for ERQ features
and specifications
ii)To calculate the price for a complete
system, add together the prices of the
Air Curtain, ERQ condensing unit and
remote controller as below example:
1 No
CYQM150DK80FBN
£4,199.00
1 No
1 No
ERQ125AV1
BRC1E52A
£1,709.00
£76.00
TOTAL
•
£5,984.00
•
Large Air Curtains: Free Hanging, Cassette and Recessed
BIDDLE STANDARD AIR CURTAIN - LARGE
CYQL100DK125*BN
*=F
Heating Capacity
Delta T
Power Input (50Hz)
Maximum Door Width
Mounting Height *2
Dimensions
Inlet = room temperature
Fan only / Heating
speed 3
speed 3
Max / Min
Height
Width
Depth
Weight
Casing
Colour
Minimum requiring ceiling void
Fan - Air Flow Rate
Heating
Sound Pressure
Heating
Refrigerant
Type
Piping Connections
Liquid (OD) / Gas
Power Supply
speed 3
speed 3
kW
k
kW
m
m
mm
mm
mm
kg
mm
m3/sec
dBA
mm
ph/V/Hz
Trade Unit Price
*=C
*=R
15.60
15
0.75 / 0.75
1.00
3.0/2.5
370
370
370
1,000
1,000
1,048
774
1105
745
76
81
83
white RAL9010
520
0.861
53
R-410A
9.52/16.0
1~/230/50
CYQL150DK200*BN
*=F
*=C
CYQL200DK250*BN
*=R
*=F
23.30
15
1.13 / 1.13
1.50
3.0/2.5
370
370
370
1,500
1,500
1,548
774
1105
745
100
118
141
white RAL9010
520
1.292
54
R-410A
9.52/19.0
1~/230/50
*=C
*=R
29.40
14
1.50 / 1.50
2.00
3.0/2.5
370
370
370
2,000
2,000
2,048
774
1105
745
126
151
155
white RAL9010
520
1.722
56
R-410A
9.52/22.0
1~/230/50
CYQL250DK250*BN
*=F
*=C
*=R
31.10
12
1.88 / 1.88
2.50
3.0/2.5
370
370
370
2,500
2,500
2,548
774
1105
745
157
190
196
white RAL9010
520
2.153
57
R-410A
9.52/22.0
1~/230/50
£4,021.00 £4,021.00 £4,032.00 £5,736.00 £5,736.00 £5,921.00 £7,121.00 £7,121.00 £7,491.00 £8,311.00 £8,311.00 £8,769.00
F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air Outlet
Accessories:
Notes:
Accessory Ref
Description
Trade Price
BRC1E52A
KRCS01-1
RTD-20/UK.FB2
Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock
Remote room mounted temperature sensor
Energy control PCB for Sky Air and VRV.
£76.00
£46.00
£251.00
Single Phase
Trade Unit Price
CYQL100DK125*BN
CYQL150DK200*BN
CYQL200DK250*BN
CYQL250DK250*BN
Three Phase
i)Please refer to page 42 for ERQ features
and specifications
ii)To calculate the price for a complete
system, add together the prices of the
Air Curtain, ERQ condensing unit and
remote controller as below example:
ERQ100AV1
ERQ125AV1
ERQ140AV1
ERQ125AW1
ERQ200AW1
ERQ250AW1
1 No
CYQL100DK125FBN
£4,021.00
£1,533.00
£1,709.00
•
£2,049.00
•
£1,743.00
•
£3,271.00
•
•
£3,408.00
1 No
1 No
ERQ125AV1
BRC1E52A
£1,709.00
£76.00
•
•
•
TOTAL
£5,806.00
Price List 2014
41
SPLIT, SKY AIR HEAT PUMPS
Medium Air Curtains: Free Hanging, Cassette and Recessed
SPLIT, SKY AIR HEAT PUMPS
Central Ducted Solutions
For central ducted distribution systems Daikin has the solution for providing cooling and heating
of the air, enabling optimal comfort and efficiency.
Even without the benefit of individual room control, the system
can provide a flexible energy saving answer over traditional
methods through the incorporation of inverter control and heat
pump technology.
The following pages include Packaged Heat Pump Rooftop
systems, with optional economisers, to heat pump condensing
units and connection kits for use with other manufacturers
heating and cooling coils.
Air handling unit
Liquid pipe
Liquid pipe
Gas pipe
Gas pipe
Field supply
EV kit
Control box
F1,F2 communication
DDC control
(control x)
Air Cooled Heat Pump Inverter
Condensing Unit Kit for DX Coil
Flexible control possibilities:
A new range of R410a inverter condensing units for
pair application with air handling units:
• Inverter controlled heat pump units
Control xl:
Full external control from 3rd party temperature controller with volt
free remote enable contact and linear variable capacity control output
• Large capacity range (from 63 to 250 class)
• Ventilation and air conditioning in 1 solution
• E KEXV-kit & control boxes are designed for outdoor installation
and can be wall mounted
Control z (BRC1D52 required):
Control via Daikin BRC1D52 remote controller and return air or remote
sensor (KRCS01-1 optional). A volt free remote enable contact is
required to confirm fan operation status. For re-circ applications only
• Per EKEXV-kit/control box, only 1 air handling unit coil can
be connected
• Outdoor unit operation range: -5°CDB ~ 43°CDB
Outdoor unit
Coil Volume dm3
1ph
3ph
ERQ100AV1
ERQ125AV1
ERQ140AV1
ERQ125AW1
ERQ200AW1
ERQ250AW1
Trade Acc. Price
Trade Unit Price
Control box
Expansion Valve Kit
control z
control y
control xl
class 63
class 80
class 100
class 125
class 140
class 200
class 250
EKEQDCB
EKEQFCB
EKEQDCB/RTD
EKEXV63
EKEXV80
EKEXV100
EKEXV125
EKEXV140
EKEXV200
EKEXV250
P
P
P
P
P
P
P
P
P
P
P
P
1.66
2.08
P
P
P
-
2.09
2.64
P
P
P
P
-
2.65
3.30
P
P
P
P
P
-
3.31
4.12
P
P
P
P
P
P
4.13
4.62
P
P
P
P
P
4.63
6.60
P
P
6.61
8.25
P
P
£365.00
£568.00
£97.00
£104.00
£78.00
£90.00
£101.00
£120.00
£132.00
min
max
£1,503.00
£1,675.00
£2,009.00
£1,709.00
£3,207.00
£3,341.00
P
P
P
P
P
P
£342.00
P: Pair Combination depending on air handling units coils volume
42
Control y:
External control from 3rd party temperature controller with volt free
remote enable contact. Fixed evaporating temperature selection,
range: +3°C to +10°C
Residential, Commercial and Industrial
X: Possibility to connect
Control xl includes RTD-20
Large Condensing Unit (Standard Noise Level)
ERAD120E-SS ERAD140E-SS ERAD170E-SS ERAD200E-SS ERAD220E-SS ERAD250E-SS ERAD310E-SS ERAD370E-SS ERAD440E-SS ERAD490E-SS
Capacity
EER
Refrigerant
Dimensions
Weight
Electrical Details
Nominal Cooling
kW
121
2.89
144
2.82
165
2.87
196
3.01
219
2.97
Length
Height
Width
mm
mm
mm
kg
V
Hz
ph
2170
2.27
1290
1564
2170
2.27
1290
1587
3070
2.27
1290
1698
3070
2.27
1290
1739
3070
2.27
1290
1886
252
3.29
306
3.3
370
3.03
435
2.96
488
3.03
3070
2.27
1290
1928
3070
2220
2240
2355
3070
2220
2240
2559
3070
2220
2240
2642
3070
2220
2240
2677
POA
POA
POA
POA
POA
R134a
Power Supply
400
50
3
Trade Unit Price
POA
POA
POA
POA
POA
Large Condensing Unit (Low Noise Level)
ERAD120E-SL ERAD140E-SL ERAD160E-SL ERAD190E-SL ERAD210E-SL ERAD240E-SL ERAD300E-SL ERAD350E-SL ERAD410E-SL ERAD460E-SL
Capacity
EER
Refrigerant
Dimensions
Weight
Electrical Details
Nominal Cooling
kW
116
2.74
137
2.61
159
2.76
187
2.82
209
2.83
Length
Height
Width
mm
mm
mm
kg
V
Hz
ph
2170
2.27
1290
1712
2170
2.27
1290
1738
3070
2.27
1290
1851
3070
2.27
1290
1897
3070
2.27
1290
2046
243
3.11
295
3.22
352
2.88
409
2.72
462
2.76
3070
2.27
1290
2091
3070
2220
2240
2534
3070
2220
2240
2741
3070
2220
2240
2834
3070
2220
2240
2873
POA
POA
POA
POA
POA
R134a
Power Supply
Trade Unit Price
400
50
3
POA
POA
POA
POA
POA
Features:
ERAD-E are a range of cooling only R134a condensing units for pair
application with air handling units
• Large capacity range 100 kW to 410 kW
• Superior control logic using the new MicroTech III controller
• Single circuit units
• Screw compressor with capacity control down to 25%
• Available in both standard and low noise configurations
Please contact your sales office for further information on these products
Rooftop Packaged Unit – Heat Pump UATYQ
UATYQ250CY1 UATYQ350CY1 UATYQ450CY1 UATYQ550CY1 UATYQ600CY1 UATYQ700CY1
Capacity
Dimensions
Weight
Air Flow Rate
External Static
Air Flow Rate
Refrigerant
Sound Power Level
Drain size
Electrical Details
Nominal Cooling
Nominal Heating
Height
Width
Depth
Indoor
Indoor
Outdoor
kW
kW
mm
mm
mm
kg
m3/min
Pa
m3/min
27.34
24.91
1150
1638
2063
490
93
147
0
35.58
34.79
1028
2209
2113
660
122
147
0
44.72
41.79
1130
2209
2113
690
160
147
0
55.69
53.93
1048
2209
2670
780
190
206
0
66.82
61.69
1302
2209
2670
830
205
206
0
72.60
69.61
1302
2209
2670
970
233
206
0
UATYPC10AY1
UATYPC12AY1
101.10
102.30
1974
2252
3180
1510
312
109.60
126.30
1974
2252
3180
1600
354
0
R410a
Outdoor
Power Supply
Running Current
Starting Current
Max Fuse Size
dBA
mm
V
Hz
Phase
A
A
A
Trade Unit Price
Economiser
82
83
0
R407C
83
87
90
90
80
80
41.6
144
50
£10,190.00
46.5
148
50
£10,904.00
74.2
175 , 215
125
£14,559.00
82.9
215x2
125
£15,816.00
25.4 (OD)
400
50
3ph
20.5
118
32
£5,027.00
26.4
93
40
£5,234.00
33.1
123
40
£8,612.00
39.4
137
50
£9,476.00
ECONO250AY1 ECONO350AY1 ECONO450AY1 ECONO550AY1 ECONO600AY1 ECONO700AY1
Trade Unit Price
£886.00
£931.00
£976.00
£1,024.00
£1,076.00
£1,129.00
Notes:
i) Minimum Ambient operating conditions
UATYQ250~700
UATYPC10~12
Cooling
Heating
0°C
20°C
-15°C
-15°C
ii) Supplied with remote controller as standard
v)Please check stock & delivery period for all model sizes
iii) Economiser option is supplied as a kit for site assembly
vi) Standard delivery for all units does not include off-loading to kerbside
iv) Low ambient kit for models UATYPC available on request
vii) UATYQ250/350 can be off-loaded by fork-lift if there is one on site
viii)All other units require crane or HIAB. Prices for HIAB available on request
Price List 2014
43
SPLIT, SKY AIR HEAT PUMPS
Large Condensing Units ERAD-E
SPLIT, SKY AIR HEAT PUMPS
VRV
VRV
Indoor Units
46
VRV Fan Coil Units
46
Air Curtains
54
Hot Water Connection
56
Outdoor Condensing Units
59
VRV Condensing Units – Heat Recovery
59
VRV Condensing Units – Heat Pump
64
VRV Condensing Units – Heat Pump Mini
68
VRV Condensing Units – Water Cooled
69
VRV Condensing Units – Replacement VRV-Q
71
Accessories
79
VRV Unit Accessories
Intelligent Controls
Scotland
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
VRV Fan Coil – Roundflow Cassette
FXFQ-A
Indoor Units
VRV
Capacity
UK Total Cooling
UK Sensible Cooling
UK Heating
Nominal Cooling
Nominal Heating
Air Flow Rate
High
Low
Dimensions
Height
(with Decoration Panel) Width
Depth
Weight (with Decoration Panel)
Decoration Panel
Electrical Details
Power Supply
Sound Level
Piping Connections
Running Current
Fuse Rating
Sound Pressure
kW
kW
kW
kW
kW
m3/sec
m3/sec
mm
mm
mm
kg
High
Low
Sound Power
Liquid
Gas
Phase
Hz
V
amps
amps
dBA
dBA
dBA
inches
inches
Trade Unit Price
FXFQ20A
FXFQ25A
FXFQ32A
FXFQ40A
FXFQ50A
FXFQ63A
FXFQ80A
FXFQ100A
FXFQ125A
1.80
1.60
2.50
2.20
2.50
0.21
0.15
204 (264)
840 (950)
840 (950)
19 (24.4)
2.30
1.90
3.20
2.80
3.20
0.21
0.15
204 (264)
840 (950)
840 (950)
19 (24.4)
2.90
2.60
4.00
3.60
4.00
0.21
0.15
204 (264)
840 (950)
840 (950)
19 (24.4)
3.60
3.00
5.00
4.50
5.00
0.23
0.16
204 (264)
840 (950)
840 (950)
20 (25.4)
5.70
4.60
8.00
7.10
8.00
0.28
0.18
204 (264)
840 (950)
840 (950)
21 (26.4)
7.20
5.80
10.00
9.00
10.00
0.38
0.21
246 (306)
840 (950)
840 (950)
24 (29.4)
9.00
6.90
12.50
11.20
12.50
0.44
0.21
246 (306)
840 (950)
840 (950)
24 (29.4)
11.30
8.60
16.00
14.00
16.00
0.55
0.33
288 (348)
840 (950)
840 (950)
26 (31.4)
0.3
0.3
0.3
0.3
0.4
0.6
0.8
1.3
31.0
28.0
49
1/4
1/2
31.0
28.0
49
1/4
1/2
31.0
28.0
49
1/4
1/2
33.0
29.0
51
1/4
1/2
4.50
3.60
6.30
5.60
6.30
0.25
0.18
204 (264)
840 (950)
840 (950)
21 (26.4)
BYCQ140D
1ph
50
230
0.4
5
33.0
29.0
51
1/4
1/2
35.0
30.0
53
3/8
5/8
38.0
30.0
55
3/8
5/8
43.0
30.0
60
3/8
5/8
45.0
36.0
61
3/8
5/8
£759.00
£774.00
£792.00
£855.00
£897.00
£946.00
£1,009.00
£1,095.00
£1,365.00
Notes:
i) Cassette prices include standard decoration panel - self cleaning panel available as an accessory item
ii) For accessories please refer to pages 79 - 87
VRV Fan Coil – 600 Sq 4 Way Blow Cassette
FXZQ-A
Indoor Units
Capacity
UK Total Cooling
kW
UK Sensible Cooling
kW
UK Heating
kW
Nominal Cooling
kW
Nominal Heating
kW
Air Flow Rate
High
m3/sec
Low
m3/sec
Dimensions (with Decoration Panel)
HxWxD mm
Weight (with Decoration Panel)
kg
Decoration Panel
Electrical Details
Power Supply
Phase
Hz
V
Running Current
amps
Fuse Rating
amps
Sound Level
Sound Pressure
High
dBA
Low
dBA
Sound Power
dBA
Piping Connections
Liquid
inches
Gas
inches
Trade Unit Price
FXZQ15A
FXZQ20A
1.40
1.30
1.90
1.70
1.90
0.14
0.11
1.80
1.50
2.50
2.20
2.50
0.15
0.11
17.5 (20.2)
17.5 (20.2)
0.6
0.6
31.5
25.5
49
1/4
1/2
32.0
25.5
49
1/4
1/2
£721.00
£737.00
Notes:
i) Cassette prices include Fully Flat decoration panel in fresh white. Other colour panels available on request.
ii) For accessories please refer to pages 79 - 87
46
Residential, Commercial and Industrial
FXZQ25A
FXZQ32A
2.30
2.90
1.80
2.10
3.20
4.00
2.80
3.60
3.20
4.00
0.15
0.17
0.11
0.12
260 (306) x 575 (620) x 575 (620)
17.5 (20.2)
18 (20.7)
BYFQ60CW
1ph
50
230
0.6
0.6
5
33.0
33.5
25.5
26.0
50
51
1/4
1/4
1/2
1/2
£752.00
£769.00
FXZQ40A
FXZQ50A
3.60
2.90
5.00
4.50
5.00
0.19
0.13
4.50
3.60
6.30
5.60
6.30
0.24
0.17
18 (20.7)
18 (20.7)
0.6
0.7
37.0
28.0
54
1/4
1/2
43.0
33.0
60
1/4
1/2
£825.00
£906.00
VRV Fan Coil – 2 Way Blow Cassette
FXCQ-A
UK Total Cooling
UK Sensible Cooling
UK Heating
Nominal Cooling
Nominal Heating
Air Flow Rate
High
Low
Dimensions
Height
(with Decoration Panel) Width
Depth
Weight (with Decoration Panel)
Decoration Panel
Electrical Details
Power Supply
Sound Level
Piping Connections
Running Current
Fuse Rating
Sound Pressure
kW
kW
kW
kW
kW
m3/sec
m3/sec
mm
mm
mm
kg
High
Low
Sound Power
Liquid
Gas
Phase
Hz
V
amps
amps
dBA
dBA
dBA
inches
inches
Trade Unit Price
FXCQ20A
FXCQ25A
FXCQ32A
FXCQ40A
FXCQ50A
1.80
1.70
2.50
2.20
2.50
0.18
0.13
305 (360)
775 (1070)
620 (700)
19 (29)
2.30
2.00
3.20
2.80
3.20
0.19
0.13
305 (360)
775 (1070)
620 (700)
19 (29)
BYBCQ40H
2.90
2.30
4.00
3.60
4.00
0.19
0.13
305 (360)
775 (1070)
620 (700)
19 (29)
3.60
2.90
5.00
4.50
5.00
0.20
0.14
305 (360)
775 (1070)
620 (700)
19 (29)
BYBCQ40H
4.50
5.70
3.50
4.90
6.30
8.00
5.60
7.10
6.30
8.00
0.25
0.27
0.18
0.19
305 (360)
305 (360)
990 (1285)
990 (1285)
620 (700)
620 (700)
22 (33)
25 (36)
BYBCQ63H
FXCQ63A
FXCQ80A
FXCQ125A
7.20
11.30
5.70
8.70
10.00
16.00
9.00
14.00
10.00
16.00
0.43
0.53
0.31
0.38
305 (360)
305 (360)
1445 (1740)
1445 (1740)
620 (700)
620 (700)
33 (44)
38 (51)
BYBCQ125H
1ph
50
230
0.2
0.2
0.2
0.2
0.3
0.4
0.5
0.9
5
32.0
28.0
tbc
1/4
1/2
34.0
29.0
tbc
1/4
1/2
34.0
30.0
tbc
1/4
1/2
36.0
31.0
tbc
1/4
1/2
37.0
31.0
tbc
1/4
1/2
39.0
32.0
tbc
3/8
5/8
42.0
33.0
tbc
3/8
5/8
46.0
38.0
tbc
3/8
5/8
£854.00
£869.00
£878.00
£970.00
£1,061.00
£1,102.00
£1,265.00
£1,518.00
Notes:
i) Cassette prices include decoration panel
ii) For accessories please refer to pages 79 - 87
VRV Fan Coil – 1 Way Blow Corner Cassette
FXKQ-MA
Indoor Units
Capacity
UK Total Cooling
UK Sensible Cooling
UK Heating
Nominal Cooling
Nominal Heating
Air Flow Rate
High
Low
Dimensions
Height
(with Decoration Panel) Width
Depth
Weight (with Decoration Panel)
Decoration Panel
Electrical Details
Power Supply
Sound Level
Piping Connections
Running Current
Fuse Rating
Sound Pressure
Sound Power
Liquid
Gas
Trade Unit Price
kW
kW
kW
kW
kW
m3/sec
m3/sec
mm
mm
mm
kg
High
Low
Phase
Hz
V
amps
amps
dBA
dBA
dBA
inches
inches
FXKQ25MA
FXKQ32MA
FXKQ40MA
FXKQ63MA
2.30
2.20
3.20
2.80
3.20
0.18
0.15
215 (285)
1110 (1240)
710 (800)
31 (39.5)
2.90
2.50
4.00
3.60
4.00
0.18
0.15
215 (285)
1110 (1240)
710 (800)
31 (39.5)
BYK45F
3.60
2.80
5.00
4.50
5.00
0.22
0.17
215 (285)
1110 (1240)
710 (800)
31 (39.5)
5.70
4.50
8.00
7.10
8.00
0.30
0.25
215 (285)
1310 (1440)
710 (800)
34 (43.5)
BYK71F
0.2
0.4
1ph
50
230
0.2
0.2
5
38.0
33.0
1/4
1/2
38.0
33.0
1/4
1/2
40.0
34.0
1/4
1/2
42.0
37.0
3/8
5/8
£946.00
£956.00
£1,045.00
£1,185.00
Notes:
i) Cassette prices include decoration panel
ii) For accessories please refer to pages 79 - 87
Price List 2014
47
VRV
Indoor Units
Capacity
VRV Fan Coil – Ceiling Suspended
FXHQ-A
Indoor Units
Capacity
VRV
Air Flow Rate
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
UK Total Cooling
UK Sensible Cooling
UK Heating
Nominal Cooling
Nominal Heating
High
Low
Height x width x Depth
Power Supply
Running Current
Fuse Rating
Sound Pressure
High
Low
Sound Power
Liquid
Gas
kW
kW
kW
kW
kW
m3/sec
m3/sec
mm
kg
Phase
Hz
V
amps
amps
dBA
dBA
dBA
inches
inches
Trade Unit Price
FXHQ32A
FXHQ63A
FXHQ100A
2.90
2.30
4.00
3.60
4.00
0.23
0.17
235 x 960 x 690
24
9.00
6.30
12.50
11.20
12.50
0.49
0.32
235 x 1590 x 690
39
36.0
31.0
1/4
1/2
5.70
4.40
8.00
7.10
8.00
0.33
0.23
235 x 1270 x 690
33
1ph
50
230
0.6
5
37.0
34.0
3/8
5/8
£906.00
£1,004.00
£1,246.00
0.6
1.3
44.0
34.0
3/8
5/8
Notes:
i) For accessories please refer to pages 79 - 87
VRV Fan Coil – Under Ceiling Cassette
FXUQ-A
Indoor Units
Capacity
Air Flow Rate
Dimensions
UK Total Cooling
UK Sensible Cooling
UK Heating
Nominal Cooling
Nominal Heating
High
Low
Height
Width
Depth
Weight
Electrical Details
Power Supply
Sound Level
Running Current
Fuse Rating
Sound Pressure
Piping
Connections
High
Low
Sound Power
Liquid
Gas
Trade Unit Price
Notes:
i) For accessories please refer to pages 79 - 87
48
Residential, Commercial and Industrial
kW
kW
kW
kW
kW
m3/sec
m3/sec
mm
mm
mm
kg
Phase
Hz
V
amps
amps
dBA
dBA
dBA
inches
inches
FXUQ71A
FXUQ100A
6.40
5.20
9.00
8.00
9.00
0.38
0.27
198
950
950
26
9.00
7.00
12.50
11.20
12.50
0.52
0.35
198
950
950
27
1 ph
50
230
0.5
1.1
5.00
40.0
36.0
tbc
3/8
5/8
47.0
40.0
tbc
3/8
5/8
£1,254.00
£1,337.00
VRV Fan Coil – Small Ducted
FXDQ-M9
Capacity
Air Flow Rate
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
UK Total Cooling
UK Sensible Cooling
UK Heating
Nominal Cooling
Nominal Heating
High
Low
Height
Power Supply
Running Current
Fuse Rating
Sound Pressure
High
Low
Sound Power
Liquid
Gas
FXDQ20M9
FXDQ25M9
1.80
1.60
2.50
2.20
2.50
0.11
0.09
2.30
1.80
3.20
2.80
3.20
0.12
0.10
kW
kW
kW
kW
kW
m3/sec
m3/sec
mm
kg
Phase
Hz
V
amps
amps
dBA
dBA
dBA
inches
inches
VRV
Indoor Units
230 x 502 x 652
17
17
1ph
50
230
0.1
0.1
5
Trade Unit Price
37.0
32.0
50
1/4
1/2
37.0
32.0
50
1/4
1/2
£579.00
£597.00
Notes:
i) For accessories please refer to pages 79 - 87
ii) Fan coils supplied as standard with factory fitted filter
VRV Fan Coil – Slim Ducted
FXDQ-A
Indoor Units
Capacity
Air Flow Rate
External Static Pressure
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
FXDQ15A
UK Total Cooling
UK Sensible Cooling
UK Heating
Nominal Cooling
Nominal Heating
High
Nom
Low
High
Low
Height
Power Supply
Running Current
Fuse Rating
Sound Pressure
High
Nom.
Low
Sound Power
Liquid
Gas
Trade Unit Price
kW
kW
kW
kW
kW
m3/sec
m3/sec
m3/sec
Pa
Pa
mm
kg
Phase
Hz
V
amps
amps
dBA
dBA
dBA
dBA
inches
inches
1.40
1.30
1.90
1.70
1.90
0.13
0.12
0.11
30.0
10.0
FXDQ20A
FXDQ25A
FXDQ32A
22
1.80
2.30
1.60
1.90
2.50
3.20
2.20
2.80
2.50
3.20
0.13
0.13
0.12
0.12
0.11
0.11
30.0
30.0
10.0
10.0
200 x 700 x 620
22
22
2.90
2.20
4.00
3.60
4.00
0.13
0.12
0.11
30.0
10.0
0.3
0.3
0.3
32.0
31.0
29.0
1/4
1/2
33.0
31.0
29.0
1/4
1/2
33.0
31.0
29.0
1/4
1/2
22
1ph
50
230
0.3
5
33.0
31.0
29.0
1/4
1/2
£562.00
£579.00
£597.00
£605.00
FXDQ40A
FXDQ50A
3.60
4.50
2.80
3.50
5.00
6.30
4.50
5.60
5.00
6.30
0.18
0.21
0.16
0.18
0.14
0.17
44.0
44.0
15.0
15.0
200 x 950 x 620
26
26
FXDQ63A
5.70
4.30
8.00
7.10
8.00
0.28
0.24
0.22
44.0
15.0
200 x 1150 x 620
29
0.4
0.4
0.5
34.0
32.0
28.0
1/4
1/2
35.0
33.0
29.0
1/4
1/2
36.0
34.0
30.0
3/8
5/8
£644.00
£670.00
£691.00
Notes:
i) For accessories please refer to pages 79 - 87
ii) Fan coils supplied as standard with factory fitted filter
Price List 2014
49
VRV Fan Coil – Ducted with Inverter Fan
FXSQ-P
Indoor Units
Capacity
VRV
Air Flow Rate
External Static Pressure
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
UK Total Cooling
UK Sensible Cooling
UK Heating
Nominal Cooling
Nominal Heating
High
Low
High
Low
Height x Width x Depth
Power Supply
Running Current
Fuse Rating
Sound Pressure
High
Low
Sound Power
Liquid
Gas
kW
kW
kW
kW
kW
m3/sec
m3/sec
Pa
Pa
mm
kg
Phase
Hz
V
amps
amps
dBA
dBA
dBA
inches
inches
Trade Unit Price
FXSQ20P
FXSQ25P
FXSQ32P
1.80
1.80
2.50
2.20
2.50
0.15
0.11
70.0
30.0
2.30
2.00
3.20
2.80
3.20
0.15
0.11
70.0
30.0
300 x 550 x 700
23
2.90
2.40
4.00
3.60
4.00
0.16
0.12
70.0
30.0
23
FXSQ40P
FXSQ50P
FXSQ63P
3.60
4.50
3.40
3.90
5.00
6.30
4.50
5.60
5.00
6.30
0.27
0.27
0.18
0.18
100.0
100.0
30.0
30.0
300 x 700 x 700
26
26
23
FXSQ80P FXSQ100P FXSQ125P FXSQ140P
5.70
7.20
4.90
6.10
8.00
10.00
7.10
9.00
8.00
10.00
0.33
0.42
0.27
0.33
100.0
100.0
30.0
40.0
300 x 1000 x 700
35
35
9.00
7.30
12.50
11.20
12.50
0.53
0.38
120.0
40.0
12.90
10.40
18.00
16.00
18.00
0.77
0.53
140.0
50.0
46
11.30
9.20
16.00
14.00
16.00
0.65
0.47
120.0
40.0
300 x 1400 x 700
46
47
1ph
50
230
0.4
0.4
0.4
1.2
1.2
1.1
1.3
1.6
2.1
3.1
40.0
33.0
66
3/8
5/8
42.0
34.0
67
3/8
5/8
5
32.0
26.0
55
1/4
1/2
32.0
26.0
55
1/4
1/2
33.0
27.0
56
1/4
1/2
37.0
29.0
63
1/4
1/2
37.0
29.0
63
1/4
1/2
37.0
30.0
59
3/8
5/8
38.0
32.0
63
3/8
5/8
38.0
32.0
61
3/8
5/8
£598.00
£614.00
£622.00
£662.00
£690.00
£712.00
£812.00
£900.00
£1,030.00 £1,133.00
Notes:
i) For accessories please refer to pages 79 - 87
ii) Fan coils supplied as standard with factory fitted filter
VRV Fan Coil – High Static Ducted
FXMQ-P7
Indoor Units
Capacity
FXMQ20P7 FXMQ25P7 FXMQ32P7 FXMQ40P7 FXMQ50P7 FXMQ63P7 FXMQ80P7 FXMQ100P7 FXMQ125P7
Dimensions
UK Total Cooling
UK Sensible Cooling
UK Heating
Nominal Cooling
Nominal Heating
High
Low
High
Low
Height x Width x Depth
Weight
Electrical Details
Power Supply
Sound Level
Running Current
Fuse Rating
Sound Pressure
Air Flow Rate
External Static pressure
Piping Connections
High
Low
Sound Power
Liquid
Gas
Trade Unit Price
Notes:
i) For accessories please refer to pages 79 - 87
50
Residential, Commercial and Industrial
kW
kW
kW
kW
kW
m3/sec
m3/sec
Pa
Pa
mm
1.80
1.80
2.50
2.20
2.50
0.15
0.11
100.0
50.0
2.30
2.00
3.20
2.80
3.20
0.15
0.11
100.0
50.0
300 x 550 x 700
2.90
2.40
4.00
3.60
4.00
0.15
0.12
100.0
50.0
kg
Phase
Hz
V
amps
amps
dBA
dBA
dBA
inches
inches
23
23
23
3.60
3.40
5.00
4.50
5.00
0.27
0.18
160.0
100.0
300 x 700
x 700
26
4.50
4.10
6.30
5.60
6.30
0.30
0.25
200.0
100.0
5.70
4.90
8.00
7.10
8.00
0.33
0.27
200.0
100.0
300 x 1000 x 700
7.20
6.10
10.00
9.00
10.00
0.42
0.33
200.0
100.0
0.6
0.6
0.6
1.6
33.0
29.0
56/1/4
1/2
33.0
29.0
56/1/4
1/2
34.0
30.0
57/1/4
1/2
£798.00
£816.00
£843.00
9.00
11.30
7.30
9.20
12.50
16.00
11.20
14.00
12.50
16.00
0.53
0.65
0.38
0.47
200.0
200.0
100.0
100.0
300 x 1400 x 700
35
35
46
46
1.4
1.7
2.3
2.9
39.0
35.0
65/1/4
1/2
35
1ph
50
230
1.4
5
41.0
37.0
61/1/4
1/2
42.0
38.0
64/3/8
5/8
43.0
39.0
67/3/8
5/8
43.0
39.0
65/3/8
5/8
44.0
40.0
70/3/8
5/8
£1,001.00
£1,066.00
£1,117.00
£1,174.00
£1,301.00
£1,489.00
VRV Fan Coil – High Static Ducted
FXMQ-MA
Capacity
Air Flow Rate
External Static pressure
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
UK Total Cooling
UK Sensible Cooling
UK Heating
Nominal Cooling
Nominal Heating
High
Low
High
Low
Height x Width x Depth
Power Supply
Running Current
Fuse Rating
Sound Pressure
High
Low
Sound Power
Liquid
Gas
FXMQ200MA
FXMQ250MA
18.00
14.90
25.00
22.40
25.00
0.97
0.83
221.0
132.0
22.50
18.50
31.50
28.00
31.50
1.20
1.03
270.0
147.0
kW
kW
kW
kW
kW
m3/sec
m3/sec
Pa
Pa
mm
kg
Phase
Hz
V
amps
amps
dBA
dBA
dBA
inches
inches
VRV
Indoor Units
470 x 1380 x 1100
137
137
1ph
50
230
6.5
7.2
13
Trade Unit Price
48.0
45.0
3/8
3/4
48.0
45.0
3/8
7/8
£2,601.00
£2,662.00
Notes:
i) For accessories please refer to pages 79 - 87
VRV Fan Coil – Fresh Air Processing Ducted
FXMQ-MF
Indoor Units
Capacity
Air Flow Rate
External Static Pressure
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
UK Total Cooling
UK Sensible Cooling
UK Heating
Nominal Cooling
Nominal Heating
High
High
Height x Width x Depth
Power Supply
Running Current
Fuse Rating
Sound Pressure
Sound Power
Liquid
Gas
High
Low
kW
kW
kW
kW
kW
m3/sec
Pa
mm
kg
Phase
Hz
V
amps
amps
dBA
dBA
dBA
inches
inches
Trade Unit Price
FXMQ125MF
FXMQ200MF
FXMQ250MF
See Databook
See Databook
14.00
8.90
0.30
185.0
470 x 744 x 1100
86
See Databook
See Databook
22.40
13.90
0.47
225.0
See Databook
See Databook
28.00
17.40
0.58
205.0
470 x 1380 x 1100
43.0
3/8
5/8
123
1ph
50
230
2.6
5
48.0
3/8
3/4
48.0
3/8
7/8
£1,944.00
£3,212.00
£3,284.00
1.5
123
3.0
Notes:
i) Please contact your local sales office for guidance on installing this unit
ii) For accessories please refer to pages 79 - 87
Price List 2014
51
VRV Fan Coil – Wall Mounted
FXAQ-P
Indoor Units
Capacity
VRV
Air Flow Rate
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
FXAQ15P
UK Total Cooling
UK Sensible Cooling
UK Heating
Nominal Cooling
Nominal Heating
High
Low
Height x Width x Depth
Power Supply
Running Current
Fuse Rating
Sound Pressure
High
Low
Sound Power
Liquid
Gas
kW
kW
kW
kW
kW
m3/sec
m3/sec
mm
kg
Phase
Hz
V
amps
amps
dBA
dBA
dBA
inches
inches
Trade Unit Price
1.40
1.40
1.90
1.70
1.90
0.12
0.08
FXAQ20P
FXAQ25P
FXAQ32P
FXAQ40P
FXAQ50P
FXAQ63P
2.90
2.40
4.00
3.60
4.00
0.15
0.09
3.60
3.30
5.00
4.50
5.00
0.20
0.15
5.70
4.60
8.00
7.10
8.00
0.32
0.23
14
4.50
3.70
6.30
5.60
6.30
0.25
0.20
290 x 1050 x 238
14
0.3
0.4
0.5
39.0
34.0
1/4
1/2
42.0
36.0
1/4
1/2
46.0
39.0
3/8
5/8
£481.00
£507.00
£559.00
11
1.80
2.30
1.80
2.00
2.50
3.20
2.20
2.80
2.50
3.20
0.13
0.13
0.08
0.08
290 x 795 x 238
11
11
0
0.2
0.3
33
29
1/4
1/2
35.0
29.0
1/4
1/2
36.0
29.0
1/4
1/2
11
1ph
50
230
0.3
5
37.0
29.0
1/4
1/2
£439.00
£452.00
£464.00
£469.00
14
Notes:
i) For accessories please refer to pages 79 - 87
VRV Fan Coil – Floor Mounted Cased
FXLQ-P
Indoor Units
Capacity
Air Flow Rate
UK Total Cooling
UK Sensible Cooling
UK Heating
Nominal Cooling
Nominal Heating
High
Low
Height x Width x Depth
Dimensions
Weight
Electrical Details
Power Supply
Sound Level
Running Current
Fuse Rating
Sound Pressure
Piping Connections
High
Low
Sound Power
Liquid
Gas
Trade Unit Price
Notes:
i) For accessories please refer to pages 79 - 87
52
Residential, Commercial and Industrial
kW
kW
kW
kW
kW
m3/sec
m3/sec
mm
kg
Phase
Hz
V
amps
amps
dBA
dBA
dBA
inches
inches
FXLQ20P
FXLQ25P
FXLQ32P
FXLQ40P
FXLQ50P
FXLQ63P
1.80
1.50
2.50
2.20
2.50
0.12
0.10
2.30
1.80
3.20
2.80
3.20
0.12
0.10
2.90
2.20
4.00
3.60
4.00
0.13
0.10
3.60
2.70
5.00
4.50
5.00
0.18
0.14
4.50
3.40
6.30
5.60
6.30
0.23
0.18
5.70
4.20
8.00
7.10
8.00
0.27
0.20
27
32
32
38
38
0.5
0.5
0.5
600 x 1000 x 232
27
600 x 1140 x 232
600 x 1420 x 232
1ph
50
230
0.2
0.2
0.5
5
35.0
32.0
1/4
1/2
35.0
32.0
1/4
1/2
35.0
32.0
1/4
1/2
38.0
33.0
1/4
1/2
39.0
34.0
1/4
1/2
40.0
35.0
3/8
5/8
£695.00
£706.00
£720.00
£746.00
£754.00
£799.00
Indoor Units
Capacity
Air Flow Rate
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
UK Total Cooling
UK Sensible Cooling
UK Heating
Nominal Cooling
Nominal Heating
High
Low
Height x Width x Depth
Power Supply
Running Current
Fuse Rating
Sound Pressure
High
Low
Sound Power
Liquid
Gas
kW
kW
kW
kW
kW
m3/sec
m3/sec
mm
kg
Phase
Hz
V
amps
amps
dBA
dBA
dBA
inches
inches
Trade Unit Price
FXNQ20P
FXNQ25P
FXNQ32P
FXNQ40P
FXNQ50P
FXNQ63P
1.80
1.50
2.50
2.20
2.50
0.12
0.10
2.30
1.80
3.20
2.80
3.20
0.12
0.10
2.90
2.20
4.00
3.60
4.00
0.13
0.10
3.60
2.70
5.00
4.50
5.00
0.18
0.14
4.50
3.40
6.30
5.60
6.30
0.23
0.18
5.70
4.20
8.00
7.10
8.00
0.27
0.20
19
23
23
27
27
0.5
0.5
0.5
610 x 930 x 220
19
610 x 1070 x 220
VRV
VRV Fan Coil – Floor Mounted Chassis
FXNQ-P
610 x 1350 x 220
1ph
50
230
0.2
0.2
0.5
5
35.0
32.0
1/4
1/2
35.0
32.0
1/4
1/2
35.0
32.0
1/4
1/2
38.0
33.0
1/4
1/2
39.0
34.0
1/4
1/2
40.0
35.0
3/8
5/8
£618.00
£628.00
£641.00
£664.00
£670.00
£712.00
Notes:
i) For accessories please refer to pages 79 - 87
VRV Fan Coil – Low Level Wall Mounted
Chassis (Medium Static) UK.FXDQ
Indoor Units
Capacity
Air Flow Rate
External Static Pressure
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
UK.FXDQ15A
UK Total Cooling
UK Sensible Cooling
UK Heating
Nominal Cooling
Nominal Heating
High
Nom
Low
High
Low
Height
Power Supply
Running Current
Fuse Rating
Sound Pressure
Sound Power
Liquid
Gas
Trade Unit Price
Hi Hi
High
Low
kW
kW
kW
kW
kW
m3/sec
m3/sec
m3/sec
Pa
Pa
mm
kg
Phase
Hz
V
amps
amps
dBA
dBA
dBA
dBA
inches
inches
1.40
1.30
1.70
1.70
1.70
0.13
0.12
0.11
30.0
10.0
UK.FXDQ20A
UK.FXDQ25A
UK.FXDQ32A
22
1.80
2.30
1.60
1.90
2.50
3.20
2.20
2.80
2.50
3.20
0.13
0.13
0.12
0.12
0.11
0.11
30.0
30.0
10.0
10.0
620 x 700 x 200
22
22
2.90
2.20
4.00
3.60
4.00
0.13
0.12
0.11
30.0
10.0
0.3
0.3
0.3
32.0
31.0
29.0
1/4
1/2
33.0
31.0
29.0
1/4
1/2
33.0
31.0
29.0
1/4
1/2
22
1ph
50
230
0.3
5
33.0
31.0
29.0
1/4
1/2
£793.00
£810.00
£828.00
£836.00
UK.FXDQ40A
UK.FXDQ50A
3.60
4.50
2.80
3.50
5.00
6.30
4.50
5.60
5.00
6.30
0.18
0.21
0.16
0.18
0.14
0.17
44.0
44.0
15.0
15.0
620 x 950 x 200
26
26
UK.FXDQ63A
5.70
4.30
8.00
7.10
8.00
0.28
0.24
0.22
44.0
15.0
620 x 1150 x 200
29
0.4
0.4
0.5
34.0
32.0
28.0
1/4
1/2
35.0
33.0
29.0
1/4
1/2
36.0
34.0
30.0
3/8
5/8
£875.00
£901.00
£922.00
Notes:
i) For accessories please refer to pages 79 - 87
Price List 2014
53
VRV
Air Curtains for VRV III Heat Recovery
Biddle air curtains are the ideal solution
for retailers and consultants to combat the
issue of climate separation across their outlet or
office doorway. Using a combination of rectifier
technology, air velocity and temperature
control they deliver greater comfort to staff and
customers alike, all year round, in all weathers.
In conjunction with Biddle, Daikin VRV III heat recovery air
curtain solution combines the benefits of the Biddle air curtain
technology with the benefits of Daikin VRV III with heat recovery.
• P
rovides virtually free air curtain heating via recovered heat
from indoor units in cooling mode
• Door heights of 2.0 to 3.0 metres
• Choice of colour RAL9010:White or RAL9006:Grey
• C
onnection to the high COP heat recovery system enables
COP’s of up to 4.36
Easy and fast installation of these systems not only reduces costs
but makes expensive water systems, boilers and gas connections
redundant. Integrating a Biddle air curtain with Daikin VRV also
eliminates the need to install multiple outdoor units thereby
reducing installation time and costs further. This combination
enables Daikin to offer its customers the ultimate
environmentally conscious TOTAL SOLUTION PACKAGE
comprising cooling, heating, outdoor-indoor climate separation
and fresh air ventilation.
• Short payback times – less than 3 years
• Air curtain rectifier technology – deeply penetrating airstream
• C
onstant air velocity technology – all year round efficiency
• E uropean patent
• 1 .0 to 2.5 metre door widths
F = Free Hanging model
C = Cassette model
R = Recessed model
Small Air Curtains:
Free Hanging, Cassette and Recessed
BIDDLE STANDARD AIR CURTAIN - SMALL
CYVS100DK80*BC
*=F
Heating Capacity
Delta T
Power Input (50Hz)
Maximum Door Width
Mounting Height *2
Dimensions
Inlet = room temperature
Fan only / Heating
speed 3
speed 3
Max / Min
Height
Width
Depth
Weight
Casing
Colour
Minimum requiring ceiling void
Fan - Air Flow Rate
Heating
Sound Pressure
Heating
Refrigerant
Type
Piping Connections
Liquid (OD) / Gas
Power Supply
speed 3
speed 3
Trade Unit Price
kW
k
kW
m
m
mm
mm
mm
kg
mm
m3/sec
dBA
mm
ph/V/Hz
*=C
*=R
7.40
15
0.23 / 0.23
1.00
2.3/2.0
270
270
270
1,000
1,000
1,048
590
821
561
56
59
61
white RAL9010
420
0.323
47
R-410A
9.52/16.0
1~/230/50
CYVS150DK80*BC
*=F
*=C
CYVS200DK100*BC
*=R
9.00
15
0.35 / 0.35
1.50
2.3/2.0
270
270
270
1,500
1,500
1,548
590
821
561
66
83
88
white RAL9010
420
0.485
49
R-410A
9.52/16.0
1~/230/50
*=F
*=C
*=R
11.60
15
0.46 / 0.46
2.00
2.3/2.0
270
270
270
2,000
2,000
2,048
590
821
561
83
102
108
white RAL9010
420
0.647
50
R-410A
9.52/16.0
1~/230/50
CYVS250DK140*BC
*=F
*=C
*=R
16.20
16
0.58 / 0.58
2.50
2.3/2.0
270
270
270
2,500
2,500
2,548
590
821
561
107
129
137
white RAL9010
420
0.808
51
R-410A
9.52/19.0
1~/230/50
£3,107.00 £3,070.00 £3,200.00 £3,958.00 £3,920.00 £4,138.00 £4,783.00 £4,747.00 £5,128.00 £5,337.00 £5,299.00 £5,718.00
F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air Outlet
Accessories:
Notes:
Accessory Ref
Description
Trade Price
BRC1E52A
KRCS01-1
RTD-20/UK.FB2
Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock
Remote room mounted temperature sensor
Energy control PCB for Sky Air and VRV
£76.00
£46.00
POA
i)Biddle Remote Controller and Connection
cable Included for Fan Speed Control
ii)If RTD-20 Connected in Air Curtain
mode the Biddle Remote Controller is
NOT connected as Fan speed is Managed
by RTD-20
iii)Code “BC” is for white finish.
Aluminium finish “SC”available on request
54
Residential, Commercial and Industrial
F = Free Hanging model
C = Cassette model
R = Recessed model
Medium Air Curtains:
Free Hanging, Cassette and Recessed
CYVM100DK80*BC
*=F
Heating Capacity
Delta T
Power Input (50Hz)
Maximum Door Width
Mounting Height *2
Dimensions
Inlet = room temperature
Fan only / Heating
speed 3
speed 3
Max / Min
Height
Width
Depth
Weight
Casing
Colour
Minimum requiring ceiling void
Fan - Air Flow Rate
Heating
Sound Pressure
Heating
Refrigerant
Type
Piping Connections
Liquid (OD) / Gas
Power Supply
speed 3
speed 3
kW
k
kW
m
m
mm
mm
mm
kg
mm
m3/sec
dBA
mm
ph/V/Hz
Trade Unit Price
*=C
*=R
9.20
17
0.37 / 0.37
1.00
2.5/2.3
270
270
270
1,000
1,000
1,048
590
821
561
57
68
66
white RAL9010
420
0.446
50
R-410A
9.52/16.0
1~/230/50
CYVM150DK80*BC
*=F
*=C
CYVM200DK100*BC
*=R
11.00
14
0.56 / 0.56
1.50
2.5/2.3
270
270
270
1,500
1,500
1,548
590
821
561
73
88
93
white RAL9010
420
0.669
51
R-410A
9.52/16.0
1~/230/50
*=F
*=C
*=R
13.40
13
0.75 / 0.75
2.00
2.5/2.3
270
270
270
2,000
2,000
2,048
590
821
561
94
111
117
white RAL9010
420
0.892
53
R-410A
9.52/16.0
1~/230/50
CYVM250DK140*BC
*=F
*=C
*=R
19.90
15
0.94 / 0.94
2.50
2.5/2.3
270
270
270
2,500
2,500
2,548
590
821
561
108
136
144
white RAL9010
420
1.115
54
R-410A
9.52/19.0
1~/230/50
£3,554.00 £3,516.00 £3,648.00 £4,554.00 £4,516.00 £4,716.00 £5,642.00 £5,604.00 £5,985.00 £6,421.00 £6,384.00 £6,795.00
F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air Outlet
Accessories:
Notes:
Accessory Ref
Description
Trade Price
BRC1E52A
KRCS01-1
RTD-20/UK.FB2
Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock
Remote room mounted temperature sensor
Energy control PCB for Sky Air and VRV
£76.00
£46.00
POA
i)Biddle Remote Controller and connection
cable included for Fan Speed Control
ii)If RTD-20 Connected in Air Curtain
mode the Biddle Remote Controller is
NOT connected as Fan speed is managed
by RTD-20
iii)Code “BC” is for white finish.
Aluminium finish “SC”available on request
F = Free Hanging model
C = Cassette model
R = Recessed model
Large Air Curtains:
Free Hanging, Cassette and Recessed
BIDDLE STANDARD AIR CURTAIN - LARGE
CYVL100DK125*BC
*=F
Heating Capacity
Delta T
Power Input (50Hz)
Maximum Door Width
Mounting Height *2
Dimensions
Inlet = room temperature
Fan only / Heating
speed 3
speed 3
Max / Min
Height
Width
Depth
Weight
Casing
Colour
Minimum requiring ceiling void
Fan - Air Flow Rate
Heating
Sound Pressure
Heating
Refrigerant
Type
Piping Connections
Liquid (OD) / Gas
Power Supply
Trade Unit Price
speed 3
speed 3
kW
k
kW
m
m
mm
mm
mm
kg
mm
m3/sec
dBA
mm
ph/V/Hz
*=C
*=R
15.60
15
0.75 / 0.75
1.00
3.0/2.5
370
370
370
1,000
1,000
1,048
774
1105
745
76
81
83
white RAL9010
520
0.861
53
R-410A
9.52/16.0
1~/230/50
CYVL150DK200*BC
*=F
*=C
CYVL200DK250*BC
*=R
23.30
15
1.13 / 1.13
1.50
3.0/2.5
370
370
370
1,500
1,500
1,548
774
1105
745
100
118
141
white RAL9010
520
1.292
54
R-410A
9.52/19.0
1~/230/50
*=F
*=C
*=R
29.40
14
1.50 / 1.50
2.00
3.0/2.5
370
370
370
2,000
2,000
2,048
774
1105
745
126
151
155
white RAL9010
520
1.722
56
R-410A
9.52/22.0
1~/230/50
CYVL250DK250*BC
*=F
*=C
*=R
31.10
12
1.88 / 1.88
2.50
3.0/2.5
370
370
370
2,500
2,500
2,548
774
1105
745
157
190
196
white RAL9010
520
2.153
57
R-410A
9.52/22.0
1~/230/50
£4,528.00 £4,481.00 £4,619.00 £6,025.00 £5,978.00 £6,164.00 £7,418.00 £7,371.00 £7,741.00 £8,615.00 £8,568.00 £9,023.00
F = Free Hanging C = Cassette R = Recessed *2: Mounting Height at base of Door Curtain Air Outlet
Accessories:
Notes:
Accessory Ref
Description
Trade Price
BRC1E52A
KRCS01-1
RTD-20/UK.FB2
Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock
Remote room mounted temperature sensor
Energy control PCB for Sky Air and VRV
£76.00
£46.00
POA
i)Biddle Remote Controller and connection
cable included for Fan Speed Control
ii)If RTD-20 Connected in Air Curtain
mode the Biddle Remote Controller is
NOT connected as Fan speed is managed
by RTD-20
iii)Code “BC” is for white finish.
Aluminium finish “SC”available on request
Price List 2014
55
VRV
BIDDLE STANDARD AIR CURTAIN - MEDIUM
HT Hot Water Module for VRV III Heat Recovery
VRV
Ideally positioned for the commercial sector, Daikin UK now offers a choice of energy efficient
domestic hot water and heating solutions for w.c. facilities, kitchens and staff break out areas.
The VRV III hot water module operates with the VRV III heat recovery system to provide an energy
efficient means of producing hot water from recovered or recycled heat.
45°C - 75°C
Liquid pipe
Gas pipe
Discharge gas pipe
F1, F2 communication
Hot water
Domestic hot water
VRV indoor units
25°C - 75°C
Air handling unit
BS-Box
Thermal
store *
45°C - 75°C
Low temp. radiator
BS-Box
VRV heat recovery with
connection to heating only
hydrobox
(REYAQ10-16P)
Heating only
hydrobox for VRV
25°C - 35°C
Under floor heating
* Please refer to Daikin heating price list for this unit
Total solution heat recovery
To date, the primary operation of the VRV heat recovery system
has been to extract heat from areas of a building being cooled
and redistribute and recycle this heat for re-use in other parts
of the building with a heating requirement, often as a result of
building orientation and diversity.
However, if more heat is extracted than can be effectively
re-used this surplus heat is generally dissipated to the
atmosphere at the VRV outdoor unit and subsequently the
recovered energy is wasted.
Available for either high temperature or
low temperature water.
56
Residential, Commercial and Industrial
• High temperature cascade Hydrobox suitable for heating and
hot water applications with leaving temperatures up between
25 and 80°C. For connection to Heat Recovery systems REYAQ.
For this system the Hydrobox is complete with expansion
vessels, circulating pumps and controls built in as standard
• F or applications requiring chilled water, other capacity sizes or
different installation configurations, please contact your local
sales office for advice
• P ossibility to integrate high temperature Hydrobox with solar
collectors for domestic hot water storage. (details & prices
available on request)
HT Hot Water Module
For Connection Only to REYAQ Outdoor Series
INDOOR UNIT (HYDRO BOX)
HXHD125A
Heating & Hot water
14
125
705x600x695
92
25~80
Yes
Yes
Yes
Precoated sheet metal
Metalic Grey
230V Single Phase (20A)
12.7mm Gas 9.52mm Gas
1"
42
R134a Cascade
kW
HxWxD
heating
mm
kg
°C
dBA
Trade Unit Price Hydro Box
£2,713.00
ACCESSORY FOR HYDRO BOX
Trade Unit Price
EKRP1HBA
£107.00
DigitaI/O PCB
EKRP1AHT
Demand PCB
£107.00
EKRUAHTB
Remote user interface ( one included as standard - intregated with Hydrobox)
£161.00
EKRTWA
Wired Room thermostat ( Requires EKRP1AHTA)
£101.00
EKRTR
Wireless Room thermostat ( Requires EKRP1AHTA)
£198.00
EKRTETS
Floor temperature sensor for use with EKRTR ( Requires EKRP1AHTA)
£15.00
VRV
Function
Heating Capacity
Capacity Index
Dimensions
Empty Weight
Leaving Water Temperature Range
Drain valve
Water Pump
Expansion Vessel
Material
Colour
Hydrobox Power Supply
Refrigerant Pipe Sizes
Water Side Pipe Sizes
Sound Pressure Level
Refrigerant
Notes:
i)Hydroboxes are connectable to the
following outdoor series only: Air Cooled
Heat Recovery REYAQ-P (see page 63)
ii)Hydroboxes are inclusive of integral
expansion vessel, and pump
HT Water Tank
DOMESTIC UNVENTED HOT WATER TANK
Water Volume
Max Water Temperature
Height
Width
Depth
Empty Weight
Colour
Material Inside Tank
Material Outside Casing
Piping Connections
Water inlet H/E
(Diameter)
Water outlet H/E
Cold Water in
Hot water out
Trade Unit Price
EKHTSU200AC
l
°C
mm
mm
mm
kg
inch
inch
inch
inch
EKHTSU260AC
Unvented System (Includes EKUHWHT unvented Kit as shown below)
200
260
75
1335
1610
600
600
695
695
81
89
Metallic grey
Stainless Steel
Precoated sheet metal
3/4 "
3/4 "
3/4 "
3/4 "
£1,121.00
£1,269.00
ACCESSORIES FOR UNVENTED SYSTEMS
Trade Unit Price
EKUHWHT
Included with
EKHTSU*AC
£283.00
EKFMAHTB
Includes: Combined Pressure Reducing Valve, Non Return Valve, Strainer, Expansion Relief Valve,
Expansion Vessel, Tundish
Option for stand alone tank (ie not mounted on top of hydrobox)
Notes:
i)Hydroboxes are connectable to the
following outdoor series only: Air Cooled
Heat Recovery REYAQ-P (see page 63)
ii)Hydroboxes are inclusive of integral
expansion vessel and pump
Price List 2014
57
VRV
Low Temperature Hydrobox
HXY-A
The low temperature Hydrobox offers air-to-water
connection to VRV III Heat Pump and is ideal
for applications such as under floor heating, air
handling units and low temperature radiators.
Indoor Units
Cooling capacity
Heating capacity
Casing
Dimensions
Weight
Sound pressure level
Operation range
Nom.
Nom.
Colour
Material
Unit
Unit
Nom.
Heating
Cooling
Refrigerant
Refrigerant circuit
Water circuit
Power supply
Recommended fuses
HXY080A
8
9
kW
kW
Height x Width x Depth
Ambient
Water side
Ambient
Water side
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Type
Gas side diameter
Liquid side diameter
Piping connections diameter
Phase/Frequency/Voltage
HXY125A
12.5
14
White
Precoated sheet metal
890 x 480 x 344
44
-20~24
25~45
~-~15.9
9.5
G 1”1/4 (female)
1~/50/220-240
mm
kg
dBA
°C
°C
°C
°C
mm
mm
inch
Hz/V
A
Trade Unit Price
£1,461.00
£2,050.00
Liquid pipe
Gas pipe
F1, F2 communication
VRV indoor units
Air handling unit
Hot/cold water
Low temp. radiator
VRV III heat pump
Under floor heating
58
Residential, Commercial and Industrial
The VRV Total Solution
VRV
Many buildings today typically operate quite separate systems for heating, cooling, refrigeration
and hot water. As a result, a huge amount of energy is wasted. To provide a much more
efficient alternative, VRV technology has been developed into a total solution for heating,
cooling, refrigeration and ventilation.
The VRV total solution
Air conditioning, refrigeration and cooling IT servers can
generate masses of waste heat that can be reused to heat
and ventilate other areas of the building or to provide hot
water for wash rooms, at a much reduced cost.
By understanding the whole building’s heating and
cooling needs at the outset, an integrated climate
control solution can be delivered that offers much
higher energy efficiency levels, thus reducing the
carbon impact of a building. This means that all internal
and external conditions must be taken into account in
the design of the climate control system.
VRV III Condensing Units – Heat Recovery
REYQ-P9 – Compact (up to 16 HP)
Outdoor Units
Capacity
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure
Piping Limits
Piping Connections Systems
Nominal Cooling
Nominal Heating
Height x Width x Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Discharge
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
REYQ8P9
REYQ10P8
REYQ12P9
REYQ14P8
REYQ16P8
kW
kW
mm
kg
m3/sec
Phase
Hz
V
amps
amps
amps
22.40
25.00
1680 x 1300 x 765
331
3.17
28.00
31.50
1680 x 1300 x 765
331
3.17
40.00
45.00
1680 x 1300 x 765
339
3.92
45.00
50.00
1680 x 1300 x 765
339
4.00
11.7
74
20
13.8
74
25
18.4
4
40
23.8
4
40
kg
kg
dBA
m
m
inches
inches
inches
10.3
10.6
11.1
11.1
58
58
62
63
3/8
3/4
5/8
100~260
13
3/8
7/8
3/4
125~325
16
33.50
37.50
1680 x 1300 x 765
331
3.50
3ph
50
400
16.0
75
25
R410a
10.8
data book
60
165
data book
1/2
1 1/8
3/4
150~390
19
1/2
1 1/8
7/8
175~455
22
1/2
1 1/8
7/8
200~520
26
£4,886.00
£5,368.00
£6,509.00
£7,674.00
£9,043.00
Price List 2014
59
VRV III Condensing Units – Heat Recovery
REYQ-P9 – Compact (18 to 24 HP)
Outdoor Units
REYQ18P9
REMQ8P9
Capacity
VRV
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure
Piping Limits
Piping Connections Systems
Nominal Cooling
Nominal Heating
Height
Width
Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Discharge
Oil Equalising
kW
kW
mm
mm
mm
kg
m3/sec
Phase
Hz
V
amps
amps
amps
REYQ20P9
REMQ10P8
REMQ8P9
50.40
56.50
1680
930
765
204
3.00
REYQ22P8
REMQ12P8
REMQ10P8
55.90
62.50
1680
930
765
254
3.08
1680
930
765
204
3.00
REYQ24P8
REMQ12P8
REMQ12P8
61.50
69.00
1680
930
765
254
3.33
1680
930
765
254
3.08
REMQ12P8
67.00
75.00
1680
930
765
254
3.33
1680
930
765
254
3.33
1680
930
765
254
3.33
3ph
50
400
8.9 + 12.2
78
8.9 + 14.9
79
25
25
12.2 + 14.9
88
25
25
14.9 + 14.9
88
25
25
25
25
9.0
9.1
9.1
9.1
58
60
60
60
R410a
kg
kg
dBA
m
m
inches
inches
inches
inches
8.2
9.0
8.2
9.1
data book
58
58
58
60
165
data book
5/8
1 1/8
7/8
3/4
225~585
29
5/8
1 1/8
1 1/8
3/4
250~650
32
5/8
1 1/8
1 1/8
3/4
275~715
35
5/8
1 3/8
1 1/8
3/4
300~780
39
£10,254.00
£11,395.00
£11,877.00
£13,018.00
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
VRV III Condensing Units – Heat Recovery
REYQ-P9 – Compact (26 to 32 HP)
Outdoor Units
REYQ26P8
REMQ10P8
Capacity
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
Height
Width
Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Discharge
Oil Equalising
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
60
Residential, Commercial and Industrial
kW
kW
mm
mm
mm
kg
m3/sec
Phase
Hz
V
amps
amps
amps
REYQ28P8
REMQ16P8
REMQ12P8
73.00
81.50
1680
930
765
254
3.08
REYQ30P8
REMQ16P8
REMQ14P8
78.50
87.50
1680
1240
765
334
3.83
1680
930
765
254
3.33
REYQ32P8
REMQ16P8
REMQ16P8
85.00
95.00
1680
1240
765
334
3.83
1680
1240
765
334
3.83
REMQ16P8
90.00
100.00
1680
1240
765
334
3.83
1680
1240
765
334
3.83
1680
1240
765
334
3.83
3ph
50
400
12.2 + 22.5
98
14.9 + 22.5
98
25
40
19.6 + 22.5
108
25
40
22.5 + 22.5
109
40
40
40
40
11.7
11.7
11.7
11.7
62
63
63
63
R410a
kg
kg
dBA
m
m
inches
inches
inches
inches
9.0
11.7
9.1
11.7
data book
58
63
60
63
165
data book
3/4
1 3/8
1 1/8
3/4
325~845
42
3/4
1 3/8
1 1/8
3/4
350~910
45
3/4
1 3/8
1 1/8
3/4
375~975
48
3/4
1 3/8
1 1/8
3/4
400~1040
52
£14,411.00
£15,552.00
£16,717.00
£18,086.00
VRV III Condensing Units – Heat Recovery
REYQ-P9 – Compact (34 to 38 HP)
REYQ34P9
REMQ8P9
Capacity
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
Height
Width
Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Discharge
Oil Equalising
kW
kW
mm
mm
mm
kg
m3/sec
Phase
Hz
V
amps
amps
amps
kg
kg
dBA
m
m
inches
inches
inches
inches
REYQ36P9
REMQ10P8 REMQ16P8
REMQ8P9
1680
930
765
204
3.00
95.40
107.00
1680
930
765
254
3.08
25
8.9 + 12.2 + 22.5
101
25
40
25
8
9
12
8
58
58
63
58
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
REYQ38P8
REMQ12P8 REMQ16P8 REMQ10P8 REMQ12P8 REMQ16P8
3/4
1 3/8
1 1/8
3/4
425~1105
55
101.00
113.00
1680
930
765
254
3.33
3ph
50
400
8.9 + 14.9 + 22.5
102
25
R410a
9
data book
60
165
data book
3/4
1 5/8
1 1/8
3/4
450~1170
58
£19,297.00
£20,438.00
£20,920.00
REYQ42P8
REYQ44P8
1680
1240
765
334
3.83
1680
930
765
204
3.00
1680
930
765
254
3.08
107.00
119.00
1680
930
765
254
3.33
1680
1240
765
334
3.83
40
25
12.2 + 14.9 + 22.5
111
25
40
12
9
9
12
63
58
60
63
1680
1240
765
334
3.83
VRV
Outdoor Units
3/4
1 5/8
1 3/8
3/4
475~1235
61
VRV III Condensing Units – Heat Recovery
REYQ-P9 – Compact (40 to 44 HP)
Outdoor Units
REYQ40P8
REMQ12P8 REMQ12P8 REMQ16P8 REMQ10P8 REMQ16P8 REMQ16P8 REMQ12P8 REMQ16P8 REMQ16P8
Capacity
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
Height
Width
Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Discharge
Oil Equalising
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
kW
kW
mm
mm
mm
kg
m3/sec
Phase
Hz
V
amps
amps
amps
kg
kg
dBA
m
m
inches
inches
inches
inches
1680
930
765
254
3.33
112.00
125.00
1680
930
765
254
3.33
3/4
1 5/8
1 3/8
3/4
500~1300
64
118.00
132.00
1680
1240
765
334
3.83
3ph
50
400
12.2 + 22.5 + 22.5
122
40
R410a
12
data book
63
165
data book
3/4
1 5/8
1 3/8
3/4
525~1365
64
25
14.9 + 14.9 + 22.5
111
25
40
25
9
9
12
9
60
60
63
58
£22,061.00
£23,454.00
1680
1240
765
334
3.83
1680
930
765
254
3.08
1680
930
765
254
3.33
124.00
138.00
1680
1240
765
334
3.83
1680
1240
765
334
3.83
40
25
14.9 + 22.5 + 22.5
122
40
40
12
9
12
12
63
60
63
63
1680
1240
765
334
3.83
3/4
1 5/8
1 3/8
3/4
550~1430
64
£24,595.00
Price List 2014
61
VRV III Condensing Units – Heat Recovery
REYQ-P9 – Compact (46 to 48 HP)
Outdoor Units
Capacity
VRV
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure
Piping Limits
Piping Connections
REYQ46P8
Nominal Cooling
Nominal Heating
Height
Width
Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Discharge
Oil Equalising
kW
kW
mm
mm
mm
kg
m3/sec
Phase
Hz
V
amps
amps
amps
REMQ14P8
REMQ16P8
1680
1240
765
334
3.83
130.00
145.00
1680
1240
765
334
3.83
REYQ48P8
REMQ16P8
REMQ16P8
REMQ16P8
REMQ16P8
1680
1240
765
334
3.83
135.00
150.00
1680
1240
765
334
3.83
1680
1240
765
334
3.83
40
22.5 + 22.5 + 22.5
134
40
40
12
12
12
63
63
63
1680
1240
765
334
3.83
3ph
50
400
19.6 + 22.5 + 22.5
132
40
40
40
R410a
kg
kg
dBA
m
m
inches
inches
inches
inches
12
12
12
data book
62
63
63
165
data book
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
3/4
1 5/8
1 3/8
3/4
575~1495
64
3/4
1 5/8
1 3/8
3/4
600~1560
64
£25,760.00
£27,129.00
VRV III Condensing Units – Heat Recovery
REYQ-P9 – High COP (up to 16 HP)
Outdoor Units
REYQ8P9
REYQ10P8
REYQ12P9
REYHQ16P
REMQ8P9
Capacity
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure
Piping Limits
Piping Connections Systems
Nominal Cooling
Nominal Heating
Height
Width
Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Discharge
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
62
Residential, Commercial and Industrial
kW
kW
mm
mm
mm
kg
m3/sec
Phase
Hz
V
amps
amps
amps
22.40
25.00
1680
1300
765
331
3.17
kg
kg
dBA
m
m
inches
inches
inches
10.3
28.00
31.50
1680
1300
765
331
3.17
33.50
37.50
1680
1300
765
331
3.50
REMQ8P9
45.00
50.00
1680
930
765
204
3.00
1680
930
765
204
3.00
3ph
50
400
12
74
20
3/8
3/4
5/8
100~260
13
14
74
25
R410a
10.6
data book
58
165
data book
3/8
7/8
3/4
125~325
16
1/2
1 1/8
3/4
150~390
19
165
data book
1/2
1 1/8
N/A
200~520
26
£4,886.00
£5,368.00
£6,509.00
£9,772.00
58
165
16
75
25
10.8
60
165
8.9 + 8.9
4
25
R410a
8.2
data book
58
25
8.2
58
VRV III Condensing Units – Heat Recovery
REYQ-P9 – High COP (18 to 24 HP)
REYQ18P9
REMQ8P9
Capacity
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure
Piping Limits
Piping Connections Systems
Nominal Cooling
Nominal Heating
Height
Width
Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Discharge
Oil Equalising
kW
kW
mm
mm
mm
kg
m3/sec
Phase
Hz
V
amps
amps
amps
REYHQ20P
REMQ10P8
REMQ8P9
50.40
56.50
1680
930
765
204
3.00
REYHQ22P
REMHQ12P8
REMQ10P8
55.90
62.50
1680
930
765
254
3.08
1680
930
765
204
3.00
REYHQ24P
REMHQ12P8 REMHQ12P8 REMHQ12P8
61.50
69.00
1680
1240
765
334
3.83
1680
930
765
254
3.08
67.00
75.00
1680
1240
765
334
3.83
1680
1240
765
334
3.83
1680
1240
765
334
3.83
VRV
Outdoor Units
3ph
50
400
8.9 + 12.2
78
25
8.9 + 19.6
79
25
25
12.2 + 19.6
88
40
19.6 + 19.6
88
25
40
40
40
9
12
12
12
58
60
60
60
R410a
kg
kg
dBA
m
m
inches
inches
inches
inches
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
8.2
9.0
8
12
data book
58
58
58
60
165
data book
5/8
1 1/8
7/8
3/4
225~585
29
5/8
1 1/8
1 1/8
3/4
250~650
32
5/8
1 1/8
1 1/8
3/4
275~715
35
5/8
1 3/8
1 1/8
3/4
300~780
39
£10,254.00
£12,490.00
£12,972.00
£15,208.00
VRV III Condensing Units – Heat Recovery
Connection to HT Water Module REYAQ
Outdoor Units
Capacity
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure
Piping Limits
Piping Connections Systems
Nominal Cooling
Nominal Heating
Height x Width x Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Discharge
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
REYAQ10P
REYAQ12P
REYAQ14P
REYAQ16P
kW
kW
mm
kg
m3/sec
Phase
Hz
V
amps
amps
amps
28.00
31.50
1680 x 1300 x 765
331
3.17
33.50
37.50
1680 x 1300 x 765
331
3.50
40.00
45.00
1680 x 1300 x 765
339
3.92
45.00
50.00
1680 x 1300 x 765
339
4.00
22.1
74
25
22.3
75
25
32.8
4
40
33.0
4
40
kg
kg
dBA
m
m
inches
inches
inches
10.6
10.8
11.1
11.1
62
63
3ph
50
400
R410a
data book
58
60
100
data book
3/8
7/8
3/4
-
1/2
1 1/8
3/4
-
1/2
1 1/8
7/8
-
1/2
1 1/8
7/8
-
£4,467.00
£5,559.00
£6,552.00
£7,624.00
Notes:
i)*The REYAQ Heat Recovery Condensing unit range is designed for connection to systems that incorporate the HXHD125 high temperature hot water module
in conjunction with the standard range of VRV fan coil units.
Price List 2014
63
Heat Pump VRV IV
RYYQ-T
Replaces RXYQ-P9 / RXYHQ-P9 / RXYRQ-P9 / RXHQ-P
3 revolutionary features:
VRV
Variable refrigerant temperature
Customise your VRV for best Seasonal Efficiency and comfort:
• R
evolutionary variable refrigerant temperature control
automatically adapts the system to individual building and
climate requirements for greater efficiency and comfort
• C
ontinuously adjusts refrigerant temperature to the actual
temperature and capacity required
• D
efault mode optimised by Daikin for UK conditions with
maximum efficiency and comfort
VRV configurator
Advanced software for simplified commissioning,
servicing, configuration and customisation:
• Delivers annual cost savings of up to 28%
Continuous heating during defrost
The new standard in heating comfort:
• U
nique continuous heating technology makes VRV IV Heat
Pump the best alternative to traditional heating systems
• Simplified commissioning: graphical interface to configure,
commission and upload system settings
• Delivers uninterrupted heat, even during the defrost cycle
• Simplified servicing: additional 7-segment indicator for easy
and quick access to basic functions and error read out
• Maintains comfortable indoor climate at all times
• Manage systems over multiple sites
VRV IV Heat Pump with Continuous Heating
RYYQ-T (up to 20 HP)
Outdoor Units
Capacity
EER
ESEER
COP
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
RYYQ8T
Nominal Cooling
Nominal Heating
kW
kW
Height x Width x Depth
mm
kg
m3/sec
Pa
Phase /Hz / V
amps
amps
amps
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
kg
kg
dBA
dBA
m
m
inches
inches
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
RYYQ10T
RYYQ12T
RYYQ14T
RYYQ16T
RYYQ18T
RYYQ20T
22.40
28.00
33.50
40.00
45.00
50.00
56.00
25.00
31.50
37.50
45.00
50.00
56.00
63.00
4.30
3.84
3.73
3.64
3.46
3.40
3.03
7.53*
7.2*
6.96*
6.83*
6.5*
6.38*
5.67*
4.55
4.27
4.12
4.02
3.91
3.89
3.71
1685 x 930 x 765 1685 x 930 x 765 1685 x 930 x 765 1685 x 1240 x 765 1685 x 1240 x 765 1685 x 1240 x 765 1685 x 1240 x 765
261
268
268
364
364
398
398
2.70
2.92
3.08
3.72
4.33
4.18
4.35
78
78
78
78
78
78
78
3ph / 50 Hz / 380~415V
7.2
11.3
12.7
15.4
18.0
20.8
26.9
databook
20
25
32
32
40
40
50
R410a
5.9
6.0
6.3
10.3
10.4
11.7
11.8
data book
58
58
61
61
64
65
66
78
79
81
81
86
86
88
165
165
165
165
165
165
165
data book
3/8
3/8
1/2
1/2
1/2
5/8
5/8
3/4
7/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
100~260
125~325
150~390
175~455
200~520
225~585
250~650
64
64
64
64
64
64
64
£4,542.00
£4,963.00
£6,077.00
£7,090.00
£8,183.00
£9,116.00
£10,028.00
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
64
Residential, Commercial and Industrial
VRV IV Heat Pump with Continuous Heating
RYYQ-T (22 to 24 HP)
RYYQ22T
RYYQ24T
RYMQ10T
Capacity
EER
ESEER
COP
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
kW
kW
Height x Width x Depth
mm
kg
m3/sec
Pa
Phase /Hz / V
amps
amps
amps
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
RYMQ12T
RYMQ8T
RYMQ16T
61.50
69.00
3.77
7.07*
4.18
67.40
75.00
3.70
6.81*
4.10
1685 x 930 x 765
195
2.92
78
1685 x 930 x 765
1685 x 930 x 765
195
188
3.08
2.70
78
78
3ph / 50 Hz / 380~415V
12.7
7.2
databook
32
20
R410a
6.3
5.9
databook
61
58
81
78
10.2
25
kg
kg
dBA
dBA
m
m
inches
inches
6.0
58
79
1685 x 1240 x 765
309
4.33
78
VRV
Outdoor Units
18.0
40
10.4
64
86
165
165
databook
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
5/8
1 1/8
275~715
64
5/8
1 3/8
300~780
64
£11,040.00
£12,725.00
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
VRV IV Heat Pump with Continuous Heating
RYYQ-T (26 to 34 HP)
Outdoor Units
RYYQ26T
RYYQ28T
RYYQ30T
RYYQ32T
RYYQ34T
RYMQ12T RYMQ14T RYMQ12T RYMQ16T RYMQ12T RYMQ18T RYMQ16T RYMQ16T RYMQ16T RYMQ18T
Capacity
EER
ESEER
COP
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
m3/sec
Pa
Phase /Hz / V
amps
amps
amps
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
kg
kg
dBA
dBA
m
m
inches
inches
73.50
82.50
3.68
6.89*
4.06
78.50
87.50
3.57
6.69*
4.00
83.50
93.50
3.52
6.6*
3.98
1685
930
765
195
3.08
78
1685
1240
765
309
3.72
78
1685
930
765
195
3.08
78
1685
1240
765
309
4.33
78
3/4
1 3/8
325~845
64
3/4
1 3/8
350~910
64
1685
1685
930
1240
765
765
195
319
3.08
4.18
78
78
3ph / 50 Hz / 380~415V
12.7
20.8
databook
32
40
R410a
6.3
11.7
data book
61
65
81
86
165
data book
3/4
1 3/8
375~975
64
12.7
15.4
12.7
18.0
32
32
32
40
6.3
10.3
6.3
10.4
61
81
61
81
61
81
64
86
£13,167.00
£14,260.00
£15,193.00
90.00
100.00
3.46
6.5*
3.91
95.00
106.00
3.43
6.44*
3.90
1685
1240
765
309
4.33
78
1685
1240
765
309
4.33
78
1685
1240
765
309
4.33
78
1685
1240
765
319
4.18
78
18.0
18.0
18.0
20.8
40
40
40
40
10.4
10.4
10.4
11.7
64
86
64
86
64
86
65
86
3/4
1 3/8
400~1040
64
3/4
1 3/8
425~1105
64
£16,366.00
£17,299.00
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
Price List 2014
65
VRV IV Heat Pump with Continuous Heating
RYYQ-T (36 to 42 HP)
Outdoor Units
RYYQ36T
RYYQ38T
RYYQ40T
RYYQ42T
RYMQ16T RYMQ20T RYMQ8T RYMQ10T RYMQ20T RYMQ10T RYMQ12T RYMQ18T RYMQ10T RYMQ16T RYMQ16T
VRV
Capacity
EER
ESEER
COP
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
m3/sec
Pa
Phase /Hz / V
amps
amps
amps
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
kg
kg
dBA
dBA
m
m
inches
inches
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
101.00
113.00
3.21
6.02*
3.79
1685
1685
1240
1240
765
765
309
319
4.33
4.35
78
78
106.00
120.00
3.42
6.36*
4.01
1685
930
765
195
2.92
78
1685
930
765
188
2.70
78
18.0
26.9
databook
40
50
7.2
20
10.2
databook
25
10.4
11.8
5.9
6.0
64
86
66
88
58
78
58
79
3/4
1 5/8
450~1170
64
3/4
1 5/8
475~1235
64
£18,211.00
£19,533.00
112.00
125.00
3.61
6.74*
4.05
1685
1685
1685
1240
930
930
765
765
765
319
195
195
4.35
2.92
3.08
78
78
78
3ph / 50 Hz / 380~415V
26.9
10.2
12.7
databook
50
25
32
R410a
11.8
6.0
6.3
data book
66
58
61
88
79
81
165
data book
3/4
1 5/8
500~1300
64
1685
1240
765
319
4.18
78
1685
930
765
195
2.92
78
20.8
10.2
40
118.00
132.00
3.54
6.65*
4.00
1685
1240
765
309
4.33
78
1685
1240
765
309
4.33
78
18.0
25
18.0
databook
40
11.7
6.0
10.4
10.4
65
86
58
79
64
86
64
86
40
3/4
1 5/8
525~1365
64
£20,156.00
£21,329.00
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
VRV IV Heat Pump with Continuous Heating
RYYQ-T (44 to 48 HP)
Outdoor Units
Capacity
EER
ESEER
COP
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
RYYQ44T
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
m3/sec
Pa
Phase /Hz / V
amps
amps
amps
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
kg
kg
dBA
dBA
m
m
inches
inches
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
RYMQ12T
RYMQ16T
1685
930
765
195
3.08
78
124.00
138.00
3.54
6.62*
3.98
1685
1240
765
309
4.33
78
12.7
RYYQ46T
RYMQ16T
RYMQ14T
RYMQ16T
RYYQ48T
RYMQ16T
3/4
1 5/8
550~1430
64
130.00
145.00
3.51
6.6*
3.94
1685
1685
1685
1240
1240
1240
765
765
765
309
309
309
3.72
4.33
4.33
78
78
78
3ph / 50 Hz / 380~415V
15.4
18.0
18.0
databook
32
40
40
R410a
10.3
10.4
10.4
data book
61
64
64
81
86
86
165
data book
3/4
1 5/8
575~1495
64
£22,443.00
£23,456.00
1685
1240
765
309
4.33
78
18.0
32
18.0
databook
40
6.3
10.4
10.4
61
81
64
86
64
86
40
RYMQ16T
RYMQ16T
RYMQ16T
1685
1240
765
309
4.33
78
135.00
150.00
3.46
6.5*
3.91
1685
1240
765
309
4.33
78
1685
1240
765
309
4.33
78
18.0
18.0
40
18.0
databook
40
10.4
10.4
10.4
64
86
64
86
64
86
40
3/4
1 5/8
600~1560
64
£24,549.00
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
66
Residential, Commercial and Industrial
VRV IV Heat Pump with Continuous Heating
RYYQ-T (50 to 54 HP)
Capacity
EER
ESEER
COP
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
RYYQ50T
RYMQ16T
RYMQ16T
140.00
156.00
3.44
6.46*
3.90
1685
1240
765
309
4.33
78
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
m3/sec
Pa
Phase
amps
amps
amps
1685
1240
765
309
4.33
78
kg
kg
dBA
dBA
m
m
inches
inches
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
18.0
RYYQ52T
RYMQ18T
RYMQ16T
RYMQ18T
RYYQ54T
RYMQ18T
3/4
1 5/8
625~1625
64
145.00
162.00
3.42
6.42*
3.89
1685
1685
1685
1240
1240
1240
765
765
765
309
319
319
4.33
4.18
4.18
78
78
78
3ph / 50 Hz / 380~415V
18.0
20.8
20.8
databook
40
40
40
R410a
10.4
11.7
11.7
data book
64
65
65
86
86
86
165
data book
3/4
1 5/8
650~1690
64
£25,482.00
£26,415.00
1685
1240
765
319
4.18
78
20.8
40
18.0
databook
40
10.4
10.4
11.7
64
86
64
86
65
86
40
RYMQ18T
RYMQ18T
RYMQ18T
1685
1240
765
319
4.18
78
150.00
168.00
3.40
6.38*
3.89
1685
1240
765
319
4.18
78
1685
1240
765
319
4.18
78
20.8
20.8
40
20.8
databook
40
11.7
11.7
11.7
65
86
65
86
65
86
VRV
Outdoor Units
40
3/4
1 5/8
675~1755
64
£27,348.00
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
Price List 2014
67
VRV III Condensing Units – Heat Pump Inverter Mini
RXYSQ
Outdoor Units
Capacity
VRV
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
Height x Width x Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
kW
kW
mm
kg
m3/sec
Phase
Hz
V
amps
amps
amps
kg
kg
dBA
dBA
m
m
inches
inches
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
RXYSQ4P8V1
RXYSQ5P8V1
RXYSQ6P8V1
RXYSQ4P8Y1
RXYSQ5P8Y1
RXYSQ6P8Y1
12.60
14.20
1345 x 900 x 320
120
1.77
14.00
16.00
1345 x 900 x 320
120
1.77
1ph
50
230
20.2
4
32
15.50
18.00
1345 x 900 x 320
120
1.77
12.60
14.20
1345 x 900 x 320
120
1.77
15.50
18.00
1345 x 900 x 320
120
1.77
22.2
4
32
5.3
4
16
14.00
16.00
1345 x 900 x 320
120
1.77
3ph
50
400
6.8
4
16
50
66
51
67
53
69
15.9
4
32
7.8
4
16
R410a
4.0
data book
50
66
51
67
53
69
300
data book
3/8
5/8
50~130
8
3/8
5/8
62.5~162.5
10
3/8
3/4
70~182
12
3/8
5/8
50~130
8
3/8
5/8
62.5~162.5
10
3/8
3/4
70~182
12
£2,735.00
£3,074.00
£3,431.00
£2,788.00
£3,160.00
£3,510.00
Notes:
The VRV III-S is highly space saving, featuring a slimmer and more compact outdoor unit compared to conventional models. Supplied in three sizes of 4 HP (11.2 kW), 5HP (14 kW) and 6HP
(15.5 kW) with a single or three phase power supply. Compatible with the full range of existing VRV fan coil units providing a choice of 12 types and 72 models. Installation is improved by the
completely new casing design of the outdoor unit with a footprint of just 320mm deep by 900mm wide, which reduces installation space requirements by over 40% (14.0kW model) and enables it
to fit easily onto balconies and narrow ledges. Maximum piping length is 150m, total piping length is 300m and maximum vertical differential between outdoor and indoor units is 50m (40m when
outdoor is below indoor units). The Daikin ‘Super Wiring’ system allows shared use of the wiring between indoor and outdoor units and the centralised remote control, the non polarity of the system
obviating incorrect connection and reducing installation time.
Advanced technologies
1
2
Super aero grille
The spiral shaped ribs are aligned with the direction
of discharge flow in order to minimise turbulence and
reduce noise.
2
Smooth air inlet bell mouth
and aero spiral fan
These features assist in significantly reducing noise.
Guides are added to the bell mouth intake to reduce
turbulence in the air flow generated by fan suction.
The aero spiral fan features fan blades with bent blade
edges, further reducing turbulence.
3
68
3
1
e-Bridge circuit
Prevents accumulation of liquid refrigerant in the
condenser. This results in more efficient use of the
condenser surface under all conditions and leads in turn
to better energy efficiency. Increased evaporative capacity
stems from the newly developed refrigeration circuit, the
SCe-bridge circuit, which adds super cooling prior to the
expansion cycle. By adopting this circuit, the COPs in both
cooling and heating have been drastically improved.
Residential, Commercial and Industrial
Aero spiral fan blade tips
Conventional
New
Escaping edges are sucked in by the bent blade edges, reducing overall turbulence.
Water cooled VRV: RWEYQ-T
Ideal for large buildings
NEW
Water cooled VRV is optimal for large buildings, including tall,
multi-storey buildings, because the system can tolerate water
pressure of up to 2MPa.
What’s new:
Flexible refrigerant circuits
• Variable refrigerant temperature
Considerable flexibility is available within the refrigerant circuit.
Up to 120m actual piping length and 50m* height difference
(if the VRV-W outdoor unit is above the indoor units) can exist
between the VRV-W outdoor units and indoor units. What’s more,
water piping does not intrude on occupied spaces, so there are
no leakage problems.
* 40m if the VRV-W outdoor unit is below the indoor units.
Space saving configuration
Daikin water cooled VRV has the industry’s most compact and
lightweight design, thanks to a new water heat exchanger and
optimisation of the refrigerant control circuit. The unit weight
of 137kg* and height of 1m means that installation is easy and
stacked configuration is also possible, contributing to further
space savings.
* for 8HP and 10HP units.
Revolutionary variable refrigerant temperature
control automatically adapts the system to individual
building and climate requirements for greater
efficiency and comfort.
• VRV configurator
Simplified commissioning: graphical interface to
configure, commission and upload system settings.
Manage systems over multiple sites, saves time and
reduces errors during set-up and commissioning.
• Unified model
Standard and Geothermal systems in one unit
(Field settings required to change mode).
High sensible mode
• Water filter (strainer) included
The high sensible mode on the VRV outdoor units optimises the
performance of the units for the European climate, offering the
following benefits:
Resulting in reduced installation cost.
• H igher energy efficiency: as no energy is wasted on
unnecessary dehumidification, the system works more
efficiently in cooling mode
• Improved end-user comfort: thanks to the higher evaporation
temperature, the discharge temperature of the indoor units
will also be increased in cooling mode, providing improved
comfort levels.
VRV
Water cooled VRV uses water as its heat source. Because the system is water cooled, the outdoor air
temperature does not affect its heating capacity. In addition, water cooling means no defrost operation
is required, and the resultant rapid start-up time assures quick and comfortable heating, even in
cold environments.
•Inverter pump control
(available upon request)
Increases system efficiency.
• Additional compatibility
Connection to VKM, AHU & FXMQ-MF units now allowed.
Wide operation range
Standard water cooled outdoor units have a wide operation
range of between 10°C and 45°C inlet water temperature, both
in heating and cooling. For the geothermal series, the operation
range is extended even more, down to -10°C* in heating and 6°C
in cooling mode.
* Ethylene glycol should be added to the water when the water inlet temperature is below 5°C.
Price List 2014
69
VRV IV Water Cooled Condensing Units
Heat Pump and Heat Recovery RWEYQ-T (up to 24 HP)
Outdoor Units
RWEYQ8T RWEYQ10T
RWEYQ16T
RWEYQ18T
RWEYQ20T
RWEYQ24T
RWEYQ8T RWEYQ8T RWEYQ8T RWEYQ10T RWEYQ10T RWEYQ10T RWEYQ8T RWEYQ8T RWEYQ8T
VRV
Capacity
EER
COP
Dimensions
Weight
Electrical Details
Refrigerant Circuit
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
Phase /Hz/v
amps
amps
amps
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Sound Pressure
Piping Limits
Maximum Length
Maximum Vertical Rise
Piping Connections
Liquid
Gas
Discharge pipe size - Heat Recovery Only
Capacity Index Limit
Maximum Number of Connected Indoor Units
kg
kg
dBA
m
m
inches
inches
inches
Trade Condensing Unit Price
22.40
25.00
5.07
5.94
1000
780
550
137
28.00
31.50
4.56
5.25
1000
780
550
137
7.2
4
20
9.5
4
20
44.80
50.00
5.07
5.94
1000
780
550
137
50.40
56.50
4.77
5.53
1000
780
550
137
1000
780
550
137
1000
1000
1000
780
780
780
550
550
550
137
137
137
3ph / 50 / 400
16.7
19.0
4
4
32
32
R410a
3.5
4.2
4.2
4.2
data book
data book
54
54
120
120
50
50
5/8
5/8
1 1/8
1 1/8
225~585
250~650
36
36
14.4
4
32
3.5
4.2
data book data book
50
51
120
120
50
50
3/8
3/8
3/4
7/8
100~260 125~325
36
36
3.5
3.5
data book
53
120
50
1/2
1 1/8
200~520
36
£5,524.00 £6,807.00
£11,048.00
56.00
63.00
4.56
5.25
£12,331.00
67.20
75.00
5.07
5.94
1000
780
550
137
1000
780
550
137
1000
780
550
137
21.6
4
50
3.5
£13,614.00
3.5
data book
55
120
50
3/4
1 3/8
300~780
36
3.5
£16,572.00
Notes:
Daikin have introduced the new VRV IV Water Cooled condensing unit to compliment the rest of the VRV range.
The water cooled system has a number of advantages over an air cooled system:
• suitable for tall multi-storied buildings due to no limitations of water piping length
• wide operation range with inlet water temperatures of 10-45°C
• suitable for use with open and closed loop ground source systems on request
• the system offers greater efficiency in heating mode as there is no defrost cycle required for the water loop
• greater efficiencies than air cooled systems
VRV IV Water Cooled Condensing Units
Heat Pump and Heat Recovery RWEYQ-T (26 to 30 HP)
Outdoor Units
Capacity
EER
COP
Dimensions
Weight
Electrical Details
Refrigerant Circuit
RWEYQ26T
RWEYQ8T
RWEYQ8T
72.80
81.50
4.86
5.65
1000
780
550
137
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
Phase
amps
amps
amps
1000
780
550
137
kg
kg
dBA
m
m
inches
inches
inches
4
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Sound Pressure
Piping Limits
Maximum Length
Maximum Vertical Rise
Piping Connections
Liquid
Gas
Discharge pipe size - Heat Recovery Only
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
RWEYQ28T
RWEYQ10T
RWEYQ8T
55
120
50
3/4
1 3/8
325~845
36
78.40
88.00
4.69
5.43
1000
780
550
137
3ph / 50 / 400
26.2
4.0
50
R410a
4
data book
55
120
50
3/4
1 3/8
350~910
36
£17,855.00
£19,138.00
1000
780
550
137
1000
780
550
137
23.9
4.0
50
4
4
4
RWEYQ30T
RWEYQ10T RWEYQ10T RWEYQ10T RWEYQ10T RWEYQ10T
1000
780
550
137
1000
780
550
137
84.00
94.50
4.56
5.25
1000
780
550
137
1000
780
550
137
28.5
4.0
50
4
4
4
56
120
50
3/4
1 3/8
375~975
36
£20,421.00
Notes:
The new VRV IV Water Cooled system is supplied as a common unit and can be used in either heat pump and heat recovery modes, from size 10 to size 30 all using a three phase power supply.
The 30 hp system can connect to up to 36 indoor units. The system is fully compatible with the full range of existing VRV fan coils and controls packages.
The condensing unit is small with a foot print of 780 x 550 mm and a height of 1000 mm. Running quality with a sound pressure level of 51dB(A), it should be installed in a plant room.
70
Residential, Commercial and Industrial
4
Replacement VRV: VRV IV-Q Heat Pump
The benefits:
Increasing efficiencies
Upgrading an old R22 and R407c to a VRV-Q system will
increase system efficiency by more than 40%, thanks to recent
developments in heat pump technology and the more efficient
R-410A refrigerant.
Fast installation
Installation is quicker because the existing piping and indoor
units (in some cases) can be retained, while Daikin’s unique
automatic refrigerant charging and refrigerant pipe cleaning cuts
installation time too.
System history doesn’t restrict future usability
As a result of the combined refrigerant pipe cleaning and
automatic charging function, the piping network is completely
clean and suitable for re-use.
VRV
R22 is a hydrochlorofluorocarbon (HCFC) which was commonly used in air conditioning systems.
However, both new and recycled sources of R22 are banned from 31st December 2014. Many systems
today are still running on R22, but as supplies of R22 run low, now is the time to replace R22 systems.
The good news is that Daikin’s VRV-Q solution delivers significantly higher energy efficiencies, with the
potential of saving up to 50%, compared with installing a completely new system.
Limited and planned downtime
The installation is less intrusive and time consuming than for a
completely new system. Downtime can be carefully planned,
whereas if a problem occurs when not enough reclaimed R22 is
available, a long and unplanned downtime may occur.
Phased investment cost
Because the entire R22 system does not need to be replaced, it is
possible to upgrade the system in phases. The R22 replacement
programme can therefore be incorporated in the general
refurbishment schedule of the building, thus spreading the
investment cost.
Warranty
Unlike using drop-in refrigerants, the VRV-Q condensing unit is
provided with a manufacturer’s warranty, providing the existing
pipework condition is deemed suitable for re-use (see price list).
Possibility to increase capacity
Benefits:
• Dramatically reduced installed cost –
up to 50% saving compared with a
complete new system
• Re-use all existing pipework and possibly
existing fan coils
Cooling loads often increase subsequent to the initial installation
of the air conditioning system. The Replacement VRV (VRV-Q)
enables system capacity to be increased without changing the
refrigerant piping (depending on system characteristics). For
example: It is possible to install a 16 HP Replacement VRV on the
refrigerant piping of an R-22 10 HP system.
What’s new:
NEW
• Variable refrigerant temperature
• Flexibility to use with existing pipework
connected to other non-Daikin systems
• Automatic charging and pipework
cleaning function
Revolutionary variable refrigerant temperature
control automatically adapts the system to individual
building and climate requirements for greater
efficiency and comfort.
• VRV configurator
• Higher energy efficiency of up to 50%
and lower CO2 emissions than retrofitting
refrigerant
Simplified commissioning: graphical interface to
configure, commission and upload system settings.
Manage systems over multiple sites, saves time and
reduces errors during set-up and commissioning.
• Major potential to increase
system capacity
• New capacities
New 18 and 20 HP single condenser systems.
Price List 2014
71
VRV IV-Q Condensing Unit – Heat Pump
RXYQQ-T (up to 20 HP)
Outdoor Units
Capacity
VRV
EER
ESEER
COP
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
m3/sec
Pa
Phase /Hz / V
amps
amps
amps
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
kg
kg
dBA
dBA
m
m
inches
inches
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
RXYQQ8T
RXYQQ10T
RXYQQ12T
RXYQQ14T
RXYQQ16T
RXYQQ18T
RXYQQ20T
22.40
25.00
4.30
7.53*
4.54
1685
930
765
187
2.10
78
28.00
31.50
3.84
7.2*
4.27
1685
930
765
194
2.92
78
33.50
37.50
3.73
6.96*
4.12
1685
930
765
194
3.08
78
45.00
50.00
3.46
6.5*
3.91
1685
1240
765
305
3.88
78
50.00
56.00
3.40
6.38*
3.89
1685
1240
765
314
4.18
78
56.00
63.00
3.03
5.67*
3.71
1685
1240
765
314
4.35
78
7.2
10.2
12.7
18.0
20.8
26.9
20
25
32
40
40
50
5.2
6.0
6.3
10.4
11.7
11.8
58
78
120
58
79
120
61
81
120
64
86
120
65
86
120
66
88
120
3/8
3/4
100~260
64
3/8
7/8
125~325
64
1/2
1 1/8
150~390
64
40.00
45.00
3.64
6.83*
4.02
1685
1240
765
306
3.72
78
3ph / 50 / 400
15.4
4
32
R410a
10.3
data book
61
81
120
50
1/2
1 1/8
175~455
64
1/2
1 1/8
200~520
64
5/8
1 1/8
225~585
64
5/8
1 1/8
250~650
64
£5,077.00
£5,548.00
£6,435.00
£7,508.00
£8,665.00
£10,165.00
£11,161.00
*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrifgerant temperature control operation).
Please contact your local sales office regarding VRV IV-Q warranty and installation.
VRV IV-Q Condensing Unit – Heat Pump
RXYQQ-T (22 to 28 HP)
Outdoor Units
RXYQQ22T
RXYQQ10T
Capacity
EER
ESEER
COP
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
m3/sec
Pa
Phase /Hz / V
amps
amps
amps
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
RXYQQ24T
RXYQQ12T
RXYQQ8T
61.50
69.00
3.77
7.07*
4.18
1685
930
765
194
2.92
RXYQQ26T
RXYQQ16T
RXYQQ12T
67.40
75.00
3.70
6.81*
4.10
1685
930
765
194
3.08
1685
930
765
187
2.10
78
RXYQQ28T
RXYQQ14T
73.50
82.50
3.68
6.89*
4.06
1685
1240
765
305
3.88
1685
930
765
194
3.08
78
RXYQQ16T
78.50
87.50
3.57
6.69*
4.00
1685
1240
765
306
3.72
1685
930
765
194
3.08
1685
1240
765
305
3.88
78
78
28.1
30.7
3ph / 50 / 400
22.9
25.2
88
25
32
20
40
32
32
32
40
6.3
10.3
6.3
10.4
61
81
61
81
61
81
64
86
R410a
kg
kg
dBA
dBA
m
m
inches
inches
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
6.0
6.3
5.2
10.4
data book
58
79
61
81
58
78
64
86
120
50
5/8
1 1/8
275~715
64
5/8
1 3/8
300~780
64
3/4
1 3/8
325~845
64
3/4
1 3/8
350~910
64
£11,983.00
£13,742.00
£13,943.00
£15,100.00
*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrifgerant temperature control operation).
Please contact your local sales office regarding VRV IV-Q warranty and installation.
72
RXYQQ12T
Residential, Commercial and Industrial
VRV IV-Q Condensing Unit – Heat Pump
RXYQQ-T (30 to 36 HP)
RXYQQ30T
RXYQQ12T
Capacity
EER
ESEER
COP
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
m3/sec
Pa
Phase /Hz / V
amps
amps
amps
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
RXYQQ32T
RXYQQ18T
RXYQQ16T
83.50
93.50
3.52
6.6*
3.98
RXYQQ34T
RXYQQ16T
RXYQQ16T
90.00
100.00
3.46
6.5*
3.91
1685
930
765
194
3.08
1685
1240
765
314
4.18
1685
1240
765
305
3.88
78
RXYQQ36T
RXYQQ18T
RXYQQ16T
95.00
106.00
3.43
6.44*
3.90
1685
1240
765
305
3.88
1685
1240
765
305
3.88
78
RXYQQ20T
101.00
113.00
3.21
6.02*
3.79
1685
1240
765
314
4.18
1685
1240
765
305
3.88
1685
1240
765
314
4.35
78
78
38.8
44.9
VRV
Outdoor Units
3ph / 50 / 400
33.5
36.0
108
32
40
40
40
40
40
40
50
10.4
11.7
10.4
11.8
64
86
65
86
64
86
66
88
R410a
kg
kg
dBA
dBA
m
m
inches
inches
6.3
11.7
10.4
10.4
data book
61
81
65
86
64
86
64
86
120
50
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
3/4
1 3/8
375~975
64
3/4
1 3/8
400~1040
64
3/4
1 3/8
425~1105
64
3/4
1 5/8
450~1170
64
£16,600.00
£17,330.00
£18,830.00
£19,826.00
*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrifgerant temperature control operation).
Please contact your local sales office regarding VRV IV-Q warranty and installation.
VRV IV-Q Condensing Unit – Heat Pump
RXYQQ-T (38 to 42 HP)
Outdoor Units
RXYQQ38T
RXYQQ8T
Capacity
EER
ESEER
COP
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
m3/sec
Pa
Phase /Hz / V
amps
amps
amps
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
kg
kg
dBA
dBA
m
m
inches
inches
RXYQQ40T
RXYQQ42T
RXYQQ10T RXYQQ20T RXYQQ10T RXYQQ12T RXYQQ18T RXYQQ10T RXYQQ16T RXYQQ16T
1685
930
765
187
2.10
78
106.00
120.00
3.42
6.36*
4.01
1685
930
765
194
2.92
78
3/4
1 5/8
475~1235
64
112.00
125.00
3.61
6.74*
4.05
1685
930
765
194
3.08
78
3ph / 50 / 400
43.7
111
32
R410a
6.3
data book
61
81
120
50
3/4
1 5/8
500~1300
64
20
44.3
111
25
50
25
5.2
6.0
11.8
6.0
58
78
58
79
66
88
58
79
£21,786.00
£22,148.00
1685
1240
765
314
4.35
78
1685
930
765
194
2.92
78
1685
930
765
194
2.92
78
118.00
132.00
3.54
6.65*
4.00
1685
1240
765
305
3.88
78
1685
1240
765
305
3.88
78
40
25
46.2
122
40
40
11.7
6.0
10.4
10.4
65
86
58
79
64
86
64
86
1685
1240
765
314
4.18
78
3/4
1 5/8
525~1365
64
£22,878.00
*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrifgerant temperature control operation).
Please contact your local sales office regarding VRV IV-Q warranty and installation.
Price List 2014
73
VRV III-Q Condensing Unit – Heat Recovery
RQCEQ-P (28.0 to 45.0 kW)
Outdoor Units
RQCEQ280P
RQEQ140P
Capacity
VRV
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
Height
Width
Depth
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
kW
kW
mm
mm
mm
kg
m3/sec
Pa
Phase
Hz
V
amps
amps
amps
kg
kg
dBA
m
m
inches
inches
RQCEQ360P
RQEQ140P
RQEQ180P
28.00
32.00
1680
635
765
175
1.58
RQCEQ460P
RQEQ180P
RQEQ140P
RQEQ140P
36.00
40.00
1680
635
765
175
1.58
1680
635
765
175
1.58
1680
635
765
175
1.58
78
RQEQ180P
45.00
52.00
1680
635
765
175
1.58
78
1680
635
765
175
1.58
78
1680
635
765
175
1.58
3ph
50
400
5.5+5.5
4
8.0+8.0
4
15
15
20
10.3
10.3
10.6
54
58
54
20
R410a
10.6
data book
58
15
5.5+5.5+8.0
4
15
20
10.3
10.3
10.6
54
54
120
58
120
120
3/8
7/8
125~325
16
1/2
1
162.5~422.5
20
1/2
1 1/8
200~520
26
£6,570.00
£8,450.00
£10,795.00
50
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
Please see note on page 76 regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.
VRV III-Q Condensing Unit – Heat Recovery
RQCEQ-P (50.0 to 63.6 kW)
Outdoor Units
Capacity
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure
Piping Limits
Piping Connections
RQCEQ500P
Nominal Cooling
Nominal Heating
Height
Width
Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Discharge
Oil Equalising
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
kW
kW
mm
mm
mm
kg
m3/sec
Phase
Hz
V
amps
amps
amps
kg
kg
dBA
m
m
inches
inches
inches
inches
RQCEQ540P
RQEQ140P
RQEQ180P
RQEQ180P
RQEQ180P
1680
635
765
175
1.58
50.00
56.00
1680
635
765
175
1.58
15
5.5+8.0+8.0
4
20
20
20
10
11
11
11
54
58
58
58
RQEQ180P
5/8
1 1/8
7/8
225~585
29
54.00
60.00
1680
635
765
175
1.58
3ph
50
400
8.0+8.0+8.0
4
20
R410a
11
data book
58
120
50
5/8
1 1/8
7/8
250~650
33
£11,735.00
£12,675.00
1680
635
765
175
1.58
1680
635
765
175
1.58
RQCEQ636P
RQEQ180P
RQEQ212P
RQEQ212P
RQEQ212P
1680
635
765
179
1.83
63.60
67.20
1680
635
765
179
1.83
1680
635
765
179
1.83
20
20
11.5+11.5+11.5
4
20
20
11
11
11
11
58
60
60
60
1680
635
765
175
1.58
5/8
1 1/8
1
275~715
36
£14,937.00
Please see note on page 76 regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.
74
Residential, Commercial and Industrial
VRV III-Q Condensing Unit – Heat Recovery
RQCEQ-P (71.2 to 74.4 kW)
RQCEQ712P
RQEQ140P
Capacity
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
Height
Width
Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Discharge
Oil Equalising
kW
kW
mm
mm
mm
kg
m3/sec
Phase
Hz
V
amps
amps
amps
RQEQ180P
RQCEQ744P
RQEQ180P
RQEQ212P
RQEQ140P
RQEQ180P
71.20
78.40
1680
635
765
175
1.58
1680
635
765
175
1.58
RQEQ212P
RQEQ212P
74.40
80.80
1680
635
765
175
1.58
1680
635
765
179
1.83
1680
635
765
175
1.58
1680
635
765
175
1.58
1680
635
765
179
1.83
1680
635
765
179
1.83
VRV
Outdoor Units
3ph
50
400
15
5.5+8.0+8.0+11.5
4
20
20
20
15
5.5+8.0+11.5+11.5
4
20
20
20
R410a
kg
kg
dBA
m
m
inches
inches
inches
inches
10.3
10.6
10.6
11.2
10.3
10.6
11.2
11.2
54
58
60
60
data book
54
58
58
60
120
50
5/8
1 1/8
1
300~780
40
3/4
1 3/8
1
325~845
43
£16,714.00
£17,468.00
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
Please see note on page 76 regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.
VRV III-Q Condensing Unit – Heat Recovery
RQCEQ-P (81.6 to 84.8 kW)
Outdoor Units
RQCEQ816P
RQEQ180P
Capacity
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
Height
Width
Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Discharge
Oil Equalising
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
kW
kW
mm
mm
mm
kg
m3/sec
Phase
Hz
V
amps
amps
amps
RQEQ212P
RQCEQ848P
RQEQ212P
RQEQ212P
RQEQ212P
RQEQ212P
81.60
87.20
1680
635
765
175
1.58
1680
635
765
179
1.83
RQEQ212P
RQEQ212P
84.80
89.60
1680
635
765
179
1.83
1680
635
765
179
1.83
1680
635
765
179
1.83
1680
635
765
179
1.83
1680
635
765
179
1.83
1680
635
765
179
1.83
3ph
50
400
20
8.0+11.5+11.5+11.5
4
20
20
20
20
11.5+11.5+11.5+11.5
4
20
20
20
R410a
kg
kg
dBA
m
m
inches
inches
inches
inches
10.6
11.2
11.2
11.2
11.2
11.2
11.2
11.2
60
60
60
60
data book
58
60
60
60
120
50
3/4
1 3/8
1 1/8
350~910
47
3/4
1 3/8
1 1/8
375~975
50
£19,162.00
£19,916.00
Please see note on page 76 regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.
Price List 2014
75
VRV III-Q Warranty
Warranty and Site Services
VRV
The warranty for VRV III-Q systems operates under different conditions to
our standard warranty. To ensure complete suitability of the existing site,
a choice of optional warranty and special site services packages are
available from Daikin Airconditioning UK Ltd. These choices will ensure the
VRV III-Q system is designed and commissioned to provide the client with
complete ‘peace of mind’ operation.
The choices include:
a)Pre-order checks on the existing pipework and fan coils installed on the
clients site to ensure suitability for VRV III-Q installation
b)Commissioning of the new VRV III-Q installation to ensure correct and
efficient operation
c)DNSS EcoSave remote diagnostics and preventative monitoring system
Warranty options for 3 or 5 years are available depending on the
combination of choices chosen, and the condition that equipment is
installed and commissioned by an engineer trained and approved for VRV
equipment by Daikin Airconditioning UK Ltd.
Commissioning Log Books will need to be submitted to Daikin
Airconditioning UK Ltd to activate the warranty.
The tables below provide an overview of the choices, with a brief description
on page 77. For full details please contact your local sales office.
VRV III-Q Warranty Choices
1. VRV III-Q combined with existing fan coil units
Warranty Package Level
Site Pre-Order
Inspection
Commissioning
DNSS
Net Price
Order Code
Condensing Unit Warranty Period
Fan Coil Unit Warranty Period
By Approved Engineer
By Daikin Airconditioning UK Ltd
By Approved Engineer
By Daikin Airconditioning UK Ltd
Daikin DNSS EcoSave Monitoring
Price per complete System
8-13HP
for full warranty period
16-22HP
24-30HP
8-13HP
16-22HP
24-30HP
For Site with Existing Fan Coils
Standard
Silver
Gold
3 Years
0 Years
3
3
Additional Cost Option
£175
£175
£175
UK.FSVQ/E/STAND
UK.FSVQ/E/STAND
UK.FSVQ/E/STAND
3 Years
1 Year
3
3
3
£1,130
£1,280
£1,430
UK.FSVQ/E/SV/8-13
UK.FSVQ/E/SV/16-22
UK.FSVQ/E/SV/24-30
5 Years
1 Year
3
3
3
£1,500
£1,750
£2,000
UK.FSVQ/E/GD/8-13
UK.FSVQ/E/GD/16-22
UK.FSVQ/E/GD/24-30
2. VRV III-Q combined with new fan coil units
Warranty Package Level
Site Pre-Order
Inspection
Commissioning
DNSS
Net Price
Order Code
Condensing Unit Warranty Period
Fan Coil Unit Warranty Period
By Approved Engineer
By Daikin Airconditioning UK Ltd
By Approved Engineer
By Daikin Airconditioning UK Ltd
Daikin DNSS EcoSave Monitoring
Price per complete System
8-13HP
for full warranty period
16-22HP
24-30HP
8-13HP
16-22HP
24-30HP
Notes:
i) All prices shown are Net. No further discount can be applied.
76
Residential, Commercial and Industrial
For Site with New Fan Coils
Standard
Silver
Gold
3 Years
3 Years
3
Additional Cost Option
3
£0
£0
£0
UK.FSVQ/N/STAND
UK.FSVQ/N/STAND
UK.FSVQ/N/STAND
5 Years
5 Years
3
Additional Cost Option
3
£400
£400
£400
UK.FSVQ/N/SV/8-13
UK.FSVQ/N/SV/16-22
UK.FSVQ/N/SV/24-30
5 Years
5 Years
3
Additional Cost Option
3
3
£1,325
£1,575
£1,825
UK.FSVQ/N/GD/8-13
UK.FSVQ/N/GD/16-22
UK.FSVQ/N/GD/24-30
VRV
VRV III-Q Warranty Detail
Approved engineer
An approved engineer is an engineer who:
1. Is suitably registered in accordance with F-gas regulations;
2.Has successfully completed a Daikin Airconditioning UK Ltd VRV III Air Cooled
installation and commissioning course within the last 3 years.
Net price
Net price, exclusive of VAT and subject to our standard terms and conditions.
No other discounts are applicable.
Prices shown for site pre-order inspection and commissioning are for work
undertaken during normal working hours between 09:00 and 17:30. Any requests
for attendance to site out of these hours is subject to additional charges.
Warranty
To activate the warranty the Daikin Airconditioning UK Ltd VRV Commissioning
Log Book will need to be fully completed and submitted to Daikin Airconditioning
UK Ltd FQS department for checking. Upon receipt and validation that all required
details are provided and satisfactory, Daikin Airconditioning UK Ltd will issue a
confirmation letter that the warranty is activated. Where Daikin Airconditioning UK
Ltd will complete the commissioning we will provide a copy of the Commissioning
Log Book to the installation contractor. Except where mentioned above, our
standard warranty conditions will apply. If none of the packaged options are
chosen, then the warranty will be limited to a standard 12 month parts only cover.
Site pre-order inspection
Where included in the package, Daikin Airconditioning UK Ltd will attend the site
to check the suitability of the existing equipment and pipework for connection
to VRV-IIIQ. Where it is not possible to check operation or equipment condition,
this will also be highlighted in the final report, and appropriate recommendations
made.
If an approved engineer carries out the site inspection, then a Daikin
Airconditioning UK Ltd supplied form shall be completed and submitted to our
FQS department for checking and approval prior to any order being accepted.
The pre-order site inspection will include for the following items.
•Existing system(s) capacity – necessary to estimate required system load for
the new system
• Record all the model numbers and the serial numbers for the indoor and the
outdoor units and indicate actual installed system combinations
•Check status of the existing indoor units – necessary if the existing units are
to be reused
• Check filter condition
• Check coil condition
• Check fan motor operation – select fan only and check for air movement and
for unusual noise and vibration
•Installed pipework details – necessary to check compliance with the
manufacturer’s specification and assess install quality. This would highlight any
required rectification prior to the installation of the new system
• Provide as installed pipework diagrams. If not available, provide as installed
pipe work schematics from information gathered on site
• Check the distance from the outdoor to the farthest indoor along the pipe
work route
• Check the distance from the first Refnet fitting to the farthest indoor unit
• Check the height difference between the outdoor and the lowest indoor
when the outdoor is situated above the indoor units or height difference
between the outdoor and the highest indoor if the outdoor is situated below
the indoor units
• Check the height difference between the highest and the lowest indoor
connected to the same system
• Provide the lengths of all installed pipe sizes
• Check the installation position and angle of the Refnet Joints
• Check the condition of the pipe insulation
• Check the adequacy of the existing pipe supports
•Installed communication and control wiring – necessary to check
compliance with the manufacturer’s specification, suitability for the new system
and suitability for new controls specification
• Check sizes and type of the interconnecting communication cables between
indoor units, outdoor units and any central control systems
• Check the separation between the power wiring and the installed
controls wiring
•Power wiring to the outdoor units – necessary to check suitability for the new
outdoor units
• Check supply voltage
• Check number of outlets available adjacent to the outdoor units compound.
• Check fuse/MCB sizes and types
• Check status of the isolators
Price List 2014
77
VRV
VRV III-Q Warranty Detail
•System health check – it is important to know if the existing systems are
operating to their optimum. If there are issues which may affect the new
installation they need to identified and rectified before installation of the
new system. A comprehensive list of the operating data can be collected
by connecting a VRV Checker to each system and recording a minimum of
one hour operation data for analysis. This data should be sent back to Daikin
Airconditioning UK Ltd FQS department for analysis
• Operate the whole system in cooling for ½ hour and in heating for ½ hour to
collect representative data
• Send data to Daikin Airconditioning UK Ltd FQS department for analysis
•System history check – although the new VRV-IIIQ system is designed to
re-use existing pipework and in some cases existing indoor units it is still
necessary to know the existing systems operational history to judge its integrity
for the new application
• Check for presence of leak protection dye and acid level – use total test kit
• Ensure that no Acid Away chemical has ever been added to the system
refrigerant charge
•Existing system controls – investigate currently installed local controls,
centralised controls and connection to the third party systems. This is
particularly necessary if any existing controls are planned to be re-used
Commissioning
Dependant on the warranty package chosen, either an approved engineer
or Daikin Airconditioning UK Ltd will provide system commissioning on the
completed installation. As mentioned in the warranty section above, a completed
log book will need to be submitted to activate the warranty
Commissioning where not provided by Daikin Airconditioning UK Ltd, can
only be completed by an approved engineer
Where Daikin Airconditioning UK Ltd provide commissioning as part of the
package this shall include:
•Check installation of new units – ensure new piping is installed correct to
Daikin specification
•Check power supplies – local isolators, MCB rating
•Fill in model number data, serial numbers etc to commissioning log book;
•Initialise VRV System and ensure all units communicate
•Set up additional control systems – ITC, Bacnet and provide demonstration
•Charge additional refrigerant
•Perform “Test” operation – including “Automatic” charging function
•Connect service checker and monitor operation – Cool>Heat>Heat Recovery
•Complete Commissioning Log Book
•Provide additional comments and recommendations if necessary
•Leave operation set as required by client
Prior to our site attendance the following shall be completed:
•All communication wiring is complete and terminated correctly
•All electrical work is complete and correct (supply wiring type and size –
breaker size correct)
•All systems piping has been pressure tested to 33 Bar
•All systems piping is evacuated to < 5 Torr
•All systems piping has been measured and is available for our information
•Sufficient additional refrigerant is available on the day
Any other works other than those detailed above are excluded.
78
Residential, Commercial and Industrial
DNSS (Daikin Network Service System)
Where Daikin Airconditioning UK Ltd provide DNSS as part of the package
this shall include the following items:
•Commissioning of DNSS system (on site service)
•GPRS router and SIM (this will be property of Daikin Airconditioning UK Ltd)
•Remote energy saving service
•24/7 monitoring of VRV operating data
•Instant notification of system malfunction (email) 7 days a week
•Malfunction prediction service (during office hours 09.00 -17.30)
•Bi-annual energy saving report indicating electricity cost saving and reduction
in CO2 emissions
•Recommendations to improve operating settings
•Issue of a DNSS user pack
All of the above will be provided for the warranty period of the VRV (either 3 or 5
years) depending on the package selected.
Prior to our site attendance the following shall be completed:
•A device compatible with DNSS is installed on site – Daikin Intelligent Manager,
Daikin Intelligent Touch Controller or Daikin LC controller. (Not included in the
price of the monitoring package)
•All electrical work is complete and correct (supply wiring type and size –
breaker size correct) also F1/F2 communications are installed
•A full set of as installed drawings are available – indicating system
configurations, installation locations and room references
•A power source is installed for the GPRS modem near the control device –
this can be powered from a standard socket
•A connection to the internet is available – for areas where there is poor GPRS
coverage a LAN or analogue phone connection must be installed near the
control device. (Installation and rental costs are not included in the price of the
monitoring package)
•Full access must be made available to the VRV equipment and if any access
equipment is required Daikin UK must be informed prior to the site visit
•A list of contacts must be issued to Daikin Airconditioning UK Ltd (these
are the contacts that should be e-mailed or telephoned in the event of a
malfunction or error with the air conditioning system). If these change in
the future, information will be given in the user pack for how to notify Daikin
Airconditioning UK Ltd of the changes
This is an extract from the Daikin publication “Warranty and Site Services Package
for VRV-IIIQ”. Please contact your local sales office to receive a copy and obtain
further information.
VRV
VRV Accessories
Price List 2014
79
VRV
VRV III Heat Recovery
Branch Selector Boxes BSVQ
Single Boxes
Dimensions
HxWxD
Weight
Total Indoor Capacity
Number of Fan Coil Units
Electrical Details
Power Supply
Piping Limits
Piping Connections
Indoor
Piping Connections
Outdoor
BSVQ100P8B
BSVQ160P8B
14
20 ~ 100
6
207 x 388 x 326
14
20 ~ 160
8
0.005
15
0.005
15
mm
kg
Phase
Hz
V
kW
amps
m
m
inches
inches
inches
inches
inches
Power Input
Fuse Rating
Level Difference
Maximum Length
Liquid
Gas
Liquid
Suction
Discharge
Multi Boxes
BSVQ250P8B
15
161 ~ 250
8
1
50
230
0.005
15
BSV4Q100PV
BSV6Q100PV
209 x 1053 x 635
60
(4 no) 20-100
4-20 *
209 x 1577 x 635
89
(6 no) 20-100
6-30 **
0.02
15
0.02
15
VRV
Boxes for Watercooled VRVIV (RWEYQ*T),
VRVQ III HR (RQCEQ-P) & VRVIII HR (REYQ*P)
data book
Trade Accessory price
3/8
5/8
3/8
5/8
1/2
3/8
5/8
3/8
5/8
1/2
3/8
7/8
3/8
7/8
3/4
3/8
5/8
1/2
3/4
1 1/8
3/8
5/8
5/8
1 1/8
1 1/8
£337.00
£372.00
£427.00
£1,344.00
£2,043.00
* BSV4Q100PV MUST have the minimum of one indoor unit connected to at least 3 of the 4 no outlets
** BSV6Q100PV MUST have the minimum of one indoor unit connected to at least 5 of the 6 no outlets
VRV Condensing Unit Refnet Joints
For Outdoor Units
2-Pipe System Refrigerant Sizing between Refnet Joints and Indoor/Outdoor Units RXYSQ / RYYQ / RWEYQ / EMRQ
Total Capacity of
Indoor Units
RXYQ5P/
RXYSQ4-6PA
RYYQ8-54T/
EMRQ8AA-16AA
Liquid
Pipe
Below 62.5
62.5 to 162.5
Below 150
150 to below 200
200 to below 290
290 to below 420
420 to 639
640 and above
Suction
Pipe
1/4
1/2
3/8
5/8
3/8
5/8
3/8
3/4
3/8
7/8
1/2
1 1/8
5/8
1 1/8
Please contact your local sales office for selection
REY(H)Q8-24P/
REYQ8-48P8/P9/
RWEYQ8-30P/
EMRQ8AA-16AA
£29.00
£29.00
£29.00
£29.00
£36.00
£38.00
£38.00
£48.00
£114.00
£139.00
£182.00
£78.00
£153.00
£96.00
£191.00
KHRQ22M20T
KHRQ22M20T
KHRQ22M20T
KHRQ22M20T
KHRQ22M29T9
KHRQ22M64T
KHRQ22M64T
KHRQ22M75T
KHRQ22M29H
KHRQ22M64H
KHRQ22M75H
BHFQ22P1007
BHFQ22P1517
BHFP22P36C
BHFP22P54C
Refnet Header
Refnet Header
Refnet Header
Condensing Unit Branch Kit - 2 Module RYYQ, RWEYQ
Condensing Unit Branch Kit - 3 Module RYYQ
Condensing Unit Branch Kit - 2 Module RQYQ
Condensing Unit Branch Kit - 3 Module RQYQ
For Outdoor Units
Trade Price
Refnet
Selection
3-Pipe System Refrigerant Sizing between Refnet Joints and Indoor/Outdoor Units REYQ / RWEYQ / EMRQ
Total Capacity of
Indoor Units
Liquid
Pipe
Below 150
150 to below 200
200 to below 290
290 to below 420
420 to 639
640 and above
3/8
3/8
3/8
1/2
5/8
Discharge
Pipe
1/2
5/8
3/4
3/4
1 1/8
Please contact your local sales office for selection
Refnet Header
Refnet Header
Refnet Header
Condensing Unit Branch Kit - 2 Module REYQ, RWEYQ
Condensing Unit Branch Kit - 3 Module REYQ, RWEYQ
Condensing Unit Branch Kit - 2 Module RQEQ
Condensing Unit Branch Kit - 3 Module RQEQ
Condensing Unit Branch Kit - 4 Module RQEQ
Trade Price
Suction
Pipe
Refnet
Selection
5/8
3/4
7/8
1 1/8
1 1/8
KHRQ23M20T
KHRQ23M20T
KHRQ23M29T9
KHRQ23M64T
KHRQ23M64T
KHRQ23M75T
KHRQ23M29H
KHRQ23M64H
KHRQ23M75H
BHFQ23P907
BHFQ23P1357
BHFP26P36C
BHFP26P63C
BHFP26P84C
£42.00
£42.00
£55.00
£58.00
£58.00
£72.00
£157.00
£190.00
£267.00
£145.00
£293.00
£164.00
£333.00
£442.00
Price List 2014
81
VRV Accessories Remote Controllers (supplied loose)
Model
Description
Related Fan Coil
Trade Price
BRC1E52A / B
Premium wired remote controller with full text menu,
Energy features and 7 Day Time Clock
All
£76.00
BRC2C51
Wired Simplified remote controller (without auto swing)
All
£90.00
KJB111A
Recessed Fixing box for BRC2C51
(not required for UK.BRC2C Brass or Chrome Models)
All
£17.00
UK.BRC2C/CHROME/POL
BRC2C51 with Polished Chrome Facia
without Heat /Cool mode switch
All
£165.00
UK.BRC2C/CHR/POL/HC
BRC2C51 with Polished Chrome Facia
with Heat / Cool switch
All
£172.00
UK.BRC2C/CHROME/BRU
BRC2C51 with Brushed Chrome Facia
without Heat / Cool mode switch
All
£165.00
UK.BRC2C/CHR/BRU/HC
BRC2C51 with Brushed Chrome Facia
with Heat / Cool switch
All
£172.00
UK.BRC2C/BRASS/POL
BRC2C51 with Polished Brass Facia
without Heat / Cool mode switch
All
£165.00
UK.BRC2C/BRA/POL/HC
BRC2C51 with Polished Brass Facia
with Heat / Cool switch
All
£172.00
BRC4C61
Wireless remote controller
FXKQ-MA
£135.00
BRC4C62
Wireless remote controller
FXDQ-M9
£135.00
BRC4C65
Wireless remote controller
FXDQ-A, FXSQ-P, FXMQ-MA, FXMQ-MF,
FXMQ-P7, FXLQ-P, FXNQ-P
£152.00
BRC7C58
Wireless remote controller
FXUQ-A
£152.00
BRC7C52
Wireless remote controller
FXCQ-A
£152.00
BRC7E618
Wireless remote controller
FXAQ-P
£135.00
BRC7F530W
Wireless remote controller for White Ceiling Decoration Panel
FXZQ-A + BYFQ60CW
£152.00
BRC7F530S
Wireless remote controller for Silver Ceiling Decoration Panel
FXZQ-A + BYFQ60CS
£152.00
BRC7EB530W
Wireless remote for Fully Flat Cassette Old Style Decoration Panel
FXZQ-A + BYFQ60B3
£152.00
BRC7FA532F
Wireless remote controller
FXFQ-A
£152.00
BRC7G53
Wireless remote controller
FXHQ-A
£152.00
VRV
VRV Remote Control
Options
82
Residential, Commercial and Industrial
VRV Accessories Control and BMS Interfaces (supplied loose)
VRV Control and BMS Interfaces
KRP4A53
System
Unit/Group
RTD-NET
RTD-10
RTD-20
RTD-HO
KLIC-DI
DMS504B51
DMS502A51
Control Protocol
-
-
Modbus
Modbus
0-10 Volt control
4
4
-
-
-
Modbus
Modbus
KNX
LONWorks
BACnet
4
4
-
-
-
-
Resistance control
4
4
-
-
4
4
-
-
-
-
On/Off
4
4
4
4
4
4
4
4
4
4
SetPoint
4
Operating Mode
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Fan Speed
VRV
KRP2A52
Interface Method
Control Functions
4
4
4
4
4
4
4
4
4
4
Louver Setting
-
-
4
4
4
4
4
4
-
4
VAM Damper control
-
-
4
4
4
4
-
-
-
-
Control Prohibit / Restrict settings
-
-
4
4
4
4
4
-
4
4
Temperature SetPoint Limits
-
-
4
4
-
4
4
4
-
-
Scene Creation
-
-
-
-
-
-
-
4
-
-
4
4
4
4
-
4
4
4
4
4
Temperature Set Point
-
-
4
4
-
4
4
4
4
4
Operating Mode
-
-
4
4
-
4
4
4
4
4
Thermostat On
-
-
4
4
4
4
4
-
-
4
Fan Operation
-
-
4
4
-
4
4
4
-
4
Louvre Position
-
-
4
4
-
4
4
4
-
4
4
4
Monitoring Functions
On/Off
4
4
4
4
4
4
4
4
Fault Code
-
-
4
4
-
4
4
4
4
4
Remote Controller temperature
-
-
4
4
-
4
4
-
4
4
Remote Controller Mode
-
-
4
4
-
4
4
-
-
4
Number of Units
-
-
4
4
-
4
4
-
-
-
Return Air Temperature (Average/Min/Max)
-
-
4
4
-
4
4
-
4
4
Coil In/Out temperature
-
-
4
4
-
4
4
-
-
-
Filter Alarm
-
-
4
4
-
4
4
4
4
4
Defrost Operation
-
-
4
4
4
4
4
-
-
-
Temperature Set Back
-
-
-
-
-
4
4
-
-
-
Temperature Setpoint Limitation
-
-
-
4
4
4
4
-
-
-
Key Card + Window Contact
-
-
-
-
-
4
4
-
-
-
Fault
Integral Functions (BMS system not req’d)
Heating Interlock
-
-
-
4
4
-
-
-
-
-
Run / Standby
-
-
-
4
4
-
-
-
-
-
Interface
KRP2A52
KRP4A53
RTD-NET
RTD-10
RTD-20
RTD-HO
KLIC-DI
DMS504B51
DMS502A51
Trade Price
£177.00
£67.00
£165.00
£210.00
£226.00
POA
£185.00
POA
POA
Mounting Box
(FXFQ, FXCQ, FXZQ, FXUQ, FXHQ, FXDQ, FXAQ)
UK.FB2
UK.FB2
UK.FB2
UK.FB2
UK.FB2
UK.FB2
-
-
-
Trade Price
£25.00
Prices
Associated Items
£25.00
£25.00
£25.00
£25.00
£25.00
-
-
-
Expansion PCB for additional unit connection
-
-
-
-
-
-
-
DAM411B51
Trade Price
-
-
-
-
-
-
-
POA
Price List 2014
83
VRV Accessories RTD-20 Control Panels
Control Panels have been developed to allow easy installation of the RTD-20 into end-user premises.
A typical application would require 1 RTD-20 per zone within a building. The control panels are
pre-configured for up-to 8 different zones, making installation and wiring much simpler for the installer.
Description
Trade Price
VRV
Model
RTD-20 Control Panels are
sold at listed price.
No discounts will apply.
UK.ENC/RTD-20X1
Enclosure for RTD20 x 1
£300.54
UK.ENC/RTD-20X2
Enclosure for RTD-20 x 2
£765.54
UK.ENC/RTD-20X3
Enclosure for RTD-20 x 3
£1,010.81
UK.ENC/RTD-20X4
Enclosure for RTD-20 x 4
£1,256.08
UK.ENC/RTD-20X5
Enclosure for RTD-20 x 5
£1,576.35
UK.ENC/RTD-20X6
Enclosure for RTD-20 x 6
£1,826.62
UK.ENC/RTD-20X7
Enclosure for RTD-20 x 7
£2,071.89
UK.ENC/RTD-20X8
Enclosure for RTD-20 x 8
£2,317.16
Accessories for RTD-20 Control Panels
Description
Trade Price
UK.RTD-EXTSEN
UK.RTD-INTSEN
UK.RTD-CABLE
UK.RTD-PIR/7.5M
UK.RTD-PIR/15.0M
Air Curtain External Sensor
Internal Sensor for RTD Device
RS485 Cable for wiring RTD Devices 100m Roll
PIR Sensor & 7.5M Cable Assy
7.5m Extension Cable for UK.RTD-PIR/7.5M
£19.95
£12.50
£60.90
£54.00
£21.45
VRV Accessories Centralised Control Solutions
Model
84
Description
Related Unit
Trade Price
DCS601C51
Intelligent touch controller for up to 64 fan coil units
All units with F1, F2
wiring connection
£1,641.00
KJB411A
Recessed Fixing box for I-Touch controller
DCS601C51
£69.00
DCS007A51
HTTP Open Protocol Software for I-Touch controller
DCS601C51
£936.00
DCS302A52
Adaptor PCB for external on/off control of I-Touch controller and I-Touch Manager
DCS601C51
£104.00
DTA103A51
Adaptor PCB for on/off control of external device from I-Touch controller and I-Touch manager
DCS601C51
£305.00
UK.IC Config
I-Touch controller - off site configuration charge (please contact your sales office for info/prices)
DCS601C51
POA
Residential, Commercial and Industrial
VRV Accessories Centralised Control Solutions
Description
Related Unit
Trade Price
DCM601A51
I-Touch manager central touch screen controller, with integral web server and email function
All units with F1, F2
wiring connection
£2,262.00
DCM601A52
I-Touch manager Expansion Module for up to 64 fan coil units and 4 x kWh Meters
All units with F1, F2
wiring connection
£707.00
DCM601A53
I-Touch manager Integrator for single point access for up to 5 individual
I-Touch Managers controllers
DCM601A51
£2,828.00
DCM002A51
Proportional Power Distribution add-on for I-Touch manager.
Provides ability for tenant billing
DCM601A51
POA
DCM008A51
Energy Navigator Software for I-Touch manager.
For on screen energy monitoring
DCM601A51
POA
DCS302A52
Adaptor PCB for external on/off control of I-Touch controller and I-Touch Manager
DCS601C51
£104.00
DTA103A51
Adaptor PCB for on/off control of external device from I-Touch controller
and I-Touch manager
DCS601C51
£305.00
WAGO Interface
System
Modular interface system for connection to 3rd Party devices such as lights, pumps,
PIR sensors, access card readers, etc. Enables the iTM to control external devices and
provide customised interlocks for automation and energy saving logic
DCM601A51
POA
UK.IMAN/CONFIG1
I-Manager Off site configuration per FCU
DCM601A51
POA
UK.IMAN/CONFIG2
I-Manager Off site configuration & graphical layout per FCU.
(Allow 4 weeks from order to delivery)
DCM601A51
POA
UK.FS1
On site commissioning for PPD or Energy Navigator Software
DCM601A51
POA
UK.IMAN/SITE TRAIN
On Site customer training for I Touch Manager System
DCM601A51
POA
Price List 2014
VRV
Model
85
VRV Accessories
Fan Coil Accessories (supplied loose)
VRV
Model
UK.RAC4
UK.SAF4
Description
Related Unit
Trade Price
BYCQ140DG
Roundflow cassette decoration panel with self cleaning filter
FXFQ-A
£310.00
BYCQ140DW
Roundflow cassette decoration panel - white with white louvres
FXFQ-A
£160.00
BYFQ60CS
Fully Flat Cassette Decoration Panel - Silver
FXZQ-A
£198.00
BYFQ60B3
Fully Flat Cassette Decoration Panel - Old Style (FXZQ-MA style)
FXZQ-A
£170.00
KDBHQ55B140
Sealing member for air discharge outlet
FXFQ-A
£90.00
BDBHQ44C60
Sealing member for air discharge outlet - Fully Flat cassette
FXZQ-A
£91.00
KDDQ55B140 1&2
Fresh air intake kit for up to 20% fresh air (Not compatible with self-cleaning
decoration panel)
FXFQ-A
£249.00
KDDQ50A140
Fresh air intake kit for up to 20% fresh air
FXHQ-A
£158.00
BYBS32D
Return air suction grille
FXSQ20~32P
£112.00
BYBS45D
Return air suction grille
FXSQ40~50P
£121.00
BYBS71D
Return air suction grille
FXSQ63~80P
£159.00
BYBS125D
Return air suction grille
FXSQ100~140P
£198.00
EKBYBSD
Mounting Kit for BYBS*D Grille (when installed directly onto the unit body)
FXSQ-P
£28.00
UK.RAC1
Return Air Chamber, 1 x 200mm dia
FXSQ20-32P
£70.00
UK.RAC2
Return Air Chamber, 2 x 200mm dia
FXSQ40-50P
£79.00
UK.RAC3
Return Air Chamber, 2 x 200mm dia
FXSQ63-80P
£86.00
UK.RAC3A
Return Air Chamber, 3 x 200mm dia
FXSQ63-80P
£93.00
UK.RAC4
Return Air Chamber, 4 x 200mm dia
FXSQ100-125P
£116.00
UK.RAC5
Return Air Chamber, 2 x 150mm dia
FXDQ20-32A
£76.00
UK.RAC6
Return Air Chamber, 3 x 150mm dia
FXDQ40-50A
£83.00
UK.RAC7
Return Air Chamber, 4 x 150mm dia
FXDQ63A
£97.00
UK.SAF1
Supply Air Flange 1 x 200mm dia
FXSQ20-32P
£63.00
UK.SAF2
Supply Air Flange 2 x 200mm dia
FXSQ40-50P
£72.00
UK.SAF3
Supply Air Flange 2 x 200mm dia
FXSQ63-80P
£79.00
UK.SAF3A
Supply Air Flange 3 x 200mm dia
FXSQ63-80P
£84.00
UK.SAF4
Supply Air Flange 4 x 200mm dia
FXSQ100-125P
£104.00
UK.SAF5
Supply Air Flange 2 x 150mm dia
FXDQ20-32A
£67.00
UK.SAF6
Supply Air Flange 3 x 150mm dia
FXDQ40-50A
£73.00
UK.SAF7
Supply Air Flange 4 x 150mm dia
FXDQ63A
£85.00
UK.FF6/P
Filter frame and filter
FXMQ40 to 80
£100.00
UK.FF7/P
Filter frame and filter
FXMQ100 to 125
£118.00
UK.FF8
Filter frame and filter
FXMQ200 to 250
£146.00
FXFQ-A, FXZQ-A, FXQC-A, FXHQ-A,
FXUQ-A, FXSQ-P, FXMQ-P7
FXKQ-MA, FXDQ-A, FXDQ-P9,
FXMQ-MA, FXAQ-P, FXLQ-P, FXNQ-P
KRCS01-4
Remote room mounted temperature sensor
£47.00
KRCS01-1
Remote room mounted temperature sensor
K.RSS
Wireless room mounted temperature sensor and receiver
All
£89.00
RS-SE
Service and Configuration Tool for K.RSS
All
£93.00
Description
Related Unit
Trade Price
BRP2A81
Adaptor PCB for Heat Cool selection terminals
RYYQ
£102.00
EKPCCAB1
VRV Configurator Software Connection cable.
Software available from Daikin Extranet
RYYQ
£180.00
UK.CGL
Condensing Unit Guard size 100-140 including RXYSQ
£354.00
VRV Condensing Units stripped down for delivery to site where lifting into position
is difficult with traditional methods. Units are rebuilt on site by Daikin UK Engineers
and fully tested
POA
£46.00
Condensing Unit Accessories (supplied loose)
Model
Strip & Rebuild of Condensing Units
86
Residential, Commercial and Industrial
VRV Refrigerant Leak Detection System
Refrigerant Leak Detection Alarm
1) The standard BS-EN378 requires that systems containing R410a refrigerant gas such as VRV, meet the requirements regarding maximum system refrigerant
volumes that could leak within Hotel Bedroom or other similar Category Class A spaces. If these limitations are exceeded there must be an alarm system
installed within each room where this limit is not met. The alarm system must alert the occupier through both audible and visual indication, and must also alert
building staff such as supervisors, night porters etc. There is no specific requirement for the alarm system to be linked to the refrigerant system to pump down
or stop the operation, although this can be configured if required by the client.
Model
Description
Related Unit
Trade Price
UK.IAM1
Room based refrigerant gas detector with remote room mounted stainless steel facia
plate. Provides local audible and visual alarm notification. Terminals for connection
to alarm network and optional connection to VRV Fan coil to force system shut down
All
£279.00
UK.IAM2
Network alarm hub for connection of up to 16 room alarms. Hub can be connected
in a pyramid formation of 16 groups back to a single unit for connection to a central
alarm indicator panel (UK.IAMC)
All
£550.00
UK.IAMC
Alarm buzzer and lamp panel for mounting in a central building supervisor location
All
£388.00
It is recommended that guidance on the selection and installation of these systems is obtained from your local Daikin UK sales office.
Price List 2014
87
VRV
Refrigerant leak detection systems can be required by the Safety of Building Occupants , BS-EN378.
Daikin has a solution that can help meet requirements for leak detection within enclosed spaces.
DNSS EcoSave
VRV
What is the Daikin Network Service System (DNSS)?
The DNSS is a remote monitoring system, which
will allow you to continuously optimise the
running of your Daikin equipment; control your
energy consumption (so reduce your Carbon
Footprint), extend the life span of your equipment
and reduce operational costs.
Y
E N E R G P TO
GS U
SAVIN
25%
E
UNIQU N BY
O
ATI
INNOV IKIN
DA
Prevent product malfunctions
Extend product lifetime
The DNSS will analyse the data from your equipment every
minute of the day and will alert us before the equipment actually
breaks down. In this way, failures can be prevented and possible
down time reduced to an absolute minimum.
The DNSS is designed to make sure that your equipment
is maintained and running as efficiently as possible.
This optimisation will extend the lifespan of your equipment.
Remote diagnostics
The DNSS continuously checks the cleanliness of the system
filters and heat exchanger. Furthermore, the DNSS manages a
wide range of data (pressures, temperatures, running hours, etc.)
in order to let your equipment run as efficiently and trouble free
as possible. This will also prevent your equipment from using too
much energy.
Malfunction messages
In the unlikely event of a problem occurring, your regional
Daikin UK office will contact you directly. Our engineers, who
are dedicated to your installation, will inform you regarding the
nature of the problem and will help you towards the next step
of solving the problem.
Your installation under continuous monitoring
• 24/7, 365 days a year remote monitoring
• Predictive maintenance
• Improved reliability
• Improved comfort levels
• Helps increase efficiency
• Helps reduce maintenance costs
• Extends product lifetime
Extra value at low cost
• A strategy of preventing breakdowns and limiting
unnecessary maintenance visits
• Efficiently organising site interventions by diagnosing
the nature and the extent of the problem before going
to site
• Innovative technology that helps to optimise your
equipment’s potential
• Ensures the most comfortable environment in
your premises
88
Residential, Commercial and Industrial
Ventilation
90
VENTILATION
VAM / VKM
Scotland
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
Ventilation
With the advent of new building regulations,
greater awareness of increasing energy costs and a
responsibility towards environmental issues, modern
commercial spaces are insulated better than ever.
Daikin offers a variety of solutions for the provision of fresh air
ventilation to offices, hotels, stores and other commercial outlets.
Heat Reclaim Ventilation
Proper ventilation is a key component of climate control in
buildings, offices and shops. In its basic function, it ensures a
flow of incoming fresh air and outgoing stale air. Our HRV (heat
reclaim ventilation) solution can do much more. It can recover
heat and OPTIMISE THE BALANCE BETWEEN INDOOR AND
OUTDOOR TEMPERATURE AND HUMIDITY, thus reducing the
load on the system and increasing efficiency.
Double glazing, thicker insulation and draught exclusion of
course, help considerably towards reducing heating/cooling
demand and burdens on the environment.
VENTILATION
The down-side however, is that these same commercial spaces
have now become, in effect, sealed boxes with little or no
replenishment of the air.
Total Heat Exchanger
VAM / VKM
VAM150FA VAM250FA VAM350FB VAM500FB VAM650FB VAM800FB VAM1000FB VAM1500FB VAM2000FB VKM50G
Dimensions
Height
Width
Depth
Weight
Duct Connections
Air Flow Rate
Ultra-High
High
Low
External Static
Ultra-High
Pressure
High
Low
Sound Pressure
Ultra-High
Level (Heat
High
Exchange Mode) Low
Electrical Details Power Supply
Running Current
Max Fuse Size
mm
mm
mm
kg
mm
m3/hr
m3/hr
m3/hr
Pa
Pa
Pa
dBA
dBA
dBA
V
Hz
Phase
A
A
Trade Unit Price
Optional Accessory Compatibility
285
776
525
24
100Ø
150
150
110
69
39
20
28.5
27.5
21.5
301
828
816
33
150Ø
250
250
155
64
39
20
29.0
27.0
22.0
150Ø
350
350
230
98
32.0
31.5
23.5
364
1004
726
1514
868
52
200Ø
500
500
350
98
33.0
31.5
24.5
200Ø
650
650
500
93
34.5
33.0
27.0
250Ø
800
800
670
137
36.0
34.5
31.0
VKM100G
387
1764
1156
64
250Ø
1000
1000
870
157
36.0
35.0
31.0
868
131
350Ø
1500
1500
1200
137
39.5
38.0
34.0
1156
152
350Ø
2000
2000
1400
137
40.0
38.0
35.0
832
96
200Ø
500
500
440
180
150
110
39.0
37.0
35.5
109
250Ø
750
750
640
170
120
80
41.5
39.0
37.0
114
250Ø
950
950
820
150
100
70
41.0
39.0
36.5
1214
3.0
15
5.0
15
5.0
15
3.8
15
3.8
15
3.8
15
230
50
1
0.9
15
0.9
15
0.9
15
1.3
15
1.6
15
£430.00
£514.00
£681.00
£872.00
2.5
15
£1,067.00 £1,257.00 £1,441.00 £2,201.00 £2,871.00 £2,089.00 £2,536.00 £3,016.00
VAM150FA VAM250FA VAM350FB VAM500FB VAM650FB VAM800FB VAM1000FB VAM1500FB VAM2000FB VKM50G
Inlet Heater Battery+
Air Filter
VKM80G
VH1B
-
VH2B
-
VH3B
EKAFV50F*
VH4B or VH4/AB
EKAFV80F*
EKAFV100F*
VH5B
2 x EKAFV100F*
-
VKM80G
VKM100G
-
-
+ Heater battery does NOT require PCB adaptor to connect to VAM
* available in Medium M6, Fine F7 and Fine F8. Only one filter is required to cover the whole of one side of the heat exchanger, even if the heat exchanger has two sections.
Optional Inlet Heater Battery
Capacity
Duct Diamater
kW
mm
Trade Unit Price
VH1B
VH2B
VH3B
VH4B
VH4/AB
VH5B
1.0
100
1.0
150
1.0
200
1.5
250
2.5
300
2.5
350
£590.00
£596.00
£600.00
£650.00
£644.00
£650.00
Notes:
Accessories:
Accessory Ref
Description
Trade Price
BRC1E52A
KRP2A52/UK.FB2
RTD-Net/UK.FB2
RTD-20/UK.FB2
BRP4A50
KRP50-2
BRP4A50A
EKAFV50F6
EKAFV50F7
EKAFV50F8
EKAFV80F6
EKAFV80F7
EKAFV80F8
EKAFV100F6
EKAFV100F7
EKAFV100F8
Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock
System adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Energy control PCB for Sky Air and VRV.
PCB Adaptor for VAM-A series connection to 3rd party heater
PCB Adaptor for VAM-A series connection to humidifier
PCB Adaptor for VAM-B Series connection to 3rd party heater or humidifier
Air filter for VAM350 / 500FB : Medium M6
Air filter for VAM350 / 500FB : Fine F7
Air filter for VAM350 / 500FB : Fine F8
Air filter for VAM650 / 800FB : Medium M6
Air filter for VAM650 / 800FB : Fine F8
Air filter for VAM650 / 800FB : Fine F7
Air filter for VAM1000 / 2000FB : Medium M6
Air filter for VAM1000 / 2000FB : Fine F7
Air filter for VAM1000 / 2000FB : Fine F8
£76.00
£202.00
£190.00
POA
£94.00
£107.00
£118.00
£51.00
£57.00
£62.00
£57.00
£62.00
£68.00
£87.00
£93.00
£98.00
90
Residential, Commercial and Industrial
i)Please contact your local sales office
for required options when combined
operation with an air conditioning system
is required
ii)Optional silencers, high efficiency filters
etc are available. Prices and details on
request
iii)VKM models must be connected as
the slave indoor unit of a standard
VRV indoor unit and share the same
BRC1D52 remote controller and BSVQ unit
( If connected to Heat Recovery)
iv)UK.VH-CK VAM EHBX24 conversion kit
cable included
Commercial Heating
92
Altherma Flex De-centralised
93
Altherma Flex Centralised
94
COMMERCIAL HEATING
Altherma Flex Product Overview
Dedicated Heating Line: 0845 641 9070
Scotland
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
The Daikin Altherma Flex heat pump series
The Daikin Altherma Flex heat pump is ideal for apartment buildings and community heating,
providing efficient air-to water heat pump technology for large residential and commercial buildings.
The product can be configured either as a de-centralised
or a centralised system:
De-centralised system
The hydroboxes can be located in individual dwellings, such
as apartments or collective housing, to create a de-centralised
system. Each indoor unit can be operated independently,
providing each property with individual control of heating,
hot water (cooling optional on 50 & 80 class units).
COMMERCIAL HEATING
The indoor hydrobox units are fully equipped with all the
required hydraulic components, so they can be connected easily
to the heat distribution system. Individual dwellings can also
be equipped with separate domestic hot water tanks, which are
designed to stack on top of the indoor units.
Centralised system
Alternatively, the indoor units can be
located together in one central plant area
to create a centralised system suitable
for a wide range of commercial and large
domestic applications.
The centralised indoor units offer modular
system scalability and capacity to meet the
heating demand of the overall building.
92
Residential, Commercial and Industrial
Altherma Flex Communal Heat Pump De-centralised
Daikin Altherma Flex type is the first heating system for apartments and collective housing that fully
incorporates the use of renewable energy sources, making large residential buildings more environmentally
sustainable by reducing primary energy usage – thus delivering lower running costs and CO2 emissions.
Altherma Flex Outdoor Units EMRQ
Outdoor Units
Capacity
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Nominal Heating
Height x Width x Depth
High
Power Supply
Starting current
Nominal running Current*
Maximum running current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Refrigerant Circuit
Sound Pressure
Piping Limits
Maximum Length
Maximum Vertical Rise
Liquid
Discharge
Gas
Piping Connections
EMRQ8A
22.4
EMRQ10A
28.0
190
78.4
331
190
78.4
amps
amps
amps
amps
74
7.6
17.1
20
74
9.9
22.1
25
kg
kg
dBA
m
m
mm
mm
mm
10.3
10.6
58
58
9.52
15.9
19.1
100~260
5
£4,765.00
kW
mm
kg
m3/min
Pa
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
EMRQ12A
33.6
1680 x 1300 x 765
EMRQ14A
39.2
EMRQ16A
44.8
235
78.4
240
78.4
4
14.0
32.8
40
4
16.9
33.0
40
11.1
11.1
62
63
9.52
19.1
22.2
125~325
6
210
78.4
400 V 3ph 50 Hz
75
12.6
22.3
25
R410a
10.8
Refer to Databook
60
100
40
12.7
19.1
28.6
150~390
7
12.7
22.2
28.6
175~455
9
12.7
22.2
28.6
200~520
10
£5,000.00
£5,773.00
£6,806.00
£8,021.00
339
* Nominal running current stated at -3°C ambient air temperature & 75°C leaving water temperature 100% connection ratio
Indoor Units (Hydrobox)
Function
Heating Capacity
Cooling capacity
Capacity Index
Dimensions
Empty Weight
Leaving Water Temperature Range
Leaving Water Temperature Range
Drain valve
Water Pump
Expansion Vessel
Material
Colour
Electrical Details
kW
kW
HxWxD
heating
cooling
mm
kg
°C
°C
Nominal ESP Heating
kPa
Power Supply
Starting current
Nominal running Current*
Maximum running current
Fuse Rating
Refrigerant Pipe Sizes
Water Side Pipe Sizes
Sound Pressure Level
Refrigerant
amps
amps
amps
amps
mm
dBA
Trade Unit Price Hydro Box
EKHVMRD50A
EKHVMRD80A
EKHVMYD50A
EKHVMYD80A
Heating & Hot water
Heating, hot water & cooling
5.6
9
5.6
9
n/a
5
8
50
80
50
80
705 x 600 x 695
92
120
25~80
n/a
5~20
Yes
83.7
58.8
7 litres heating
7 litres heating, 2 litres cooling
Precoated sheet metal
Metalic Grey
230V 1ph 50Hz
4
6.5
10.9
6.5
10.9
16.5
20
12.7 Gas, 9.52 Liquid
12.7 Gas, 9.52 Liquid, 15.9 Suction
1" Female
40
42
40
42
R134a Cascade
£2,479.00
£2,560.00
£3,045.00
COMMERCIAL HEATING
Altherma Flex Indoor Units EKHVMRD / EKHVMYD
Hydrobox & cylinder
shown in
combination
£3,135.00
* Nominal running current stated at -3°C ambient air temperature & 75°C leaving water temperature 100% connection ratio
Hot Water Cylinders EKHTSU
Domestic hot water cylinder
Type
Water Volume
Max Water Temperature
Height
Width
Depth
Empty Weight
Colour
Material Inside Tank
Material Outside Casing
Piping Connections
All
Insulation
Heat loss / 24hour dt 45°C
Heat exchanger surface area
Trade Unit Price
l
°C
mm
mm
mm
kg
inch
mm
m2
Accessories
EKHTSU200AC
EKHTSU260AC
Unvented System (Includes EKUHWHT unvented Kit)
200
260
75
1335
1610
600
695
70
78
Metallic grey
Stainless Steel
Precoated sheet metal
3/4 "
80
1.2
1.5
1.56
£1,113.00
Notes:
£1,261.00
Accessories for hydrobox
EKRP1AHT
EKRP1HBA
RTD-W
UK.FB2
EKCC-W
EKCLWS
EKRUAHTB
EKBUHA6V3
EKBUHA6W1
EKFMAHTB
UK.FSHEAT/COMMS
Description
Optional PCB for demand control
Optional PCB for remote alarm monitoring
MODBUS interface for HT hydrobox
Fixing box for RTD-W
Sequence controller
Additional thermistor for sequence controller
Remote user interface
In line back up heater 6kW, 1-phase, 230V
In line back up heater 6kW, 3-phase, 400V
Kit for standalone installation with floor
standing hydrobox
Commissioning assistance per hydrobox
1 to 10 hydroboxes
Commissioning assistance per hydrobox
11 to 20 hydroboxes
Commissioning assistance per hydrobox
>20 hydroboxes
Trade price
£104.00
£104.00
£205.00
£25.00
£640.00
£73.00
£157.00
£461.00
£461.00
£277.00
£240.00
£216.00
£192.00
i) Refnet joint prices can be found on page 81
ii) Commissioning assistance should be included for each hydrobox
iii) DHW cylinder required for hot water function
Price List 2014
93
Altherma Flex Communal Heat Pump Centralised
Daikin Altherma Flex type is the first centralised heating system for schools, public buildings ,
hotels, gyms & apartments that fully incorporates the use of renewable energy sources, making
large buildings more environmentally sustainable by reducing primary energy usage – thus
delivering lower running costs and CO2 emissions.
Altherma Flex Outdoor Units EMRQ
Outdoor Units
Capacity
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Nominal Heating
Height x Width x Depth
High
Power Supply
Starting current
Nominal running Current*
Maximum running current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Refrigerant Circuit
Sound Pressure
Piping Limits
Maximum Length
Maximum Vertical Rise
Liquid
Discharge
Gas
Piping Connections
EMRQ8A
22.4
EMRQ10A
28.0
190
78.4
331
190
78.4
amps
amps
amps
amps
74
7.6
17.1
20
74
9.9
22.1
25
kg
kg
dBA
m
m
mm
mm
mm
10.3
10.6
58
58
9.52
15.9
19.1
100~260
5
£4,765.00
kW
mm
kg
m3/min
Pa
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
EMRQ12A
33.6
1680 x 1300 x 765
EMRQ14A
39.2
EMRQ16A
44.8
235
78.4
240
78.4
4
14.0
32.8
40
4
16.9
33.0
40
11.1
11.1
62
63
9.52
19.1
22.2
125~325
6
210
78.4
400 V 3ph 50 Hz
75
12.6
22.3
25
R410a
10.8
Refer to Databook
60
100
40
12.7
19.1
28.6
150~390
7
12.7
22.2
28.6
175~455
9
12.7
22.2
28.6
200~520
10
£5,000.00
£5,773.00
£6,806.00
£8,021.00
339
COMMERCIAL HEATING
* Nominal running current stated at -3°C ambient air temperature & 75°C leaving water temperature 100% connection ratio
Altherma Flex Indoor Units EKHBRD
Indoor unit (Hydrobox)
Function
Heating Capacity
Cooling capacity
Capacity Index
Dimensions
Empty Weight
Leaving Water Temperature Range
Drain valve
Water Pump
Expansion Vessel
Material
Colour
Electrical Details
kW
kW
HxWxD
EKHBRD
011ACV1
EKHBRD
014ACV1
11
14
100
125
mm
kg
°C
heating
Refrigerant Pipe Sizes
Water Side Pipe Sizes
Sound Pressure Level
Refrigerant
amps
amps
amps
amps
mm
dBA
Trade Unit Price Hydro Box
EKHBRD
011ACY1
EKHBRD
014ACY1
EKHBRD
016ACY1
14
16
125
140
Heating & Hot water
16
11
n/a
140
100
705 x 600 x 695
145
148
25~80
Yes
92
Power Supply
Starting current
Nominal running Current*
Maximum running current
Fuse Rating
EKHBRD
016ACV1
11.6
22.5
88
85
92
12 litres
Precoated sheet metal
Metalic Grey
230V 1ph
4
15.1
23.8
25
18.1
23.8
88
400V 3ph
4
5.6
12.5
16
4.3
12.5
15.9 Gas, 9.52 Liquid
1” Female
46
43
R134a Cascade
43
45
£2,985.00
£3,038.00
£3,130.00
£3,045.00
85
6.7
12.5
45
46
£3,099.00
£3,192.00
* Nominal running current stated at -3°C ambient air temperature & 75°C leaving water temperature 100% connection ratio
Pre Selected Combinations
Heating capacity (1) A7W35
kW
28.0
31.4
42.0
47.0
Heating capacity (2) A-3W65
kW
23.9
26.7
34.3
38.7
Outdoor unit
Hydroboxes
Demand PCBs
Refnets
Trade price
1 x EMRQ8
2 x EKHBRD014ACV1
2 x EKRP1AHT
1 x KHRQM29T9
£11,084.00
£4,765
£6,076
£208
£35
1 x EMRQ10
2 x EKHBRD016ACV1
2 x EKRP1AHT
1 x KHRQM29T9
£5,000
£6,260
£208
£35
1 x EMRQ12
3 x EKHBRD014ACV1
3 x EKRP1AHT
1 x KHRQM64H
£11,503.00
(1) Heating ambient air temperature 7°C and leaving water temperature 35°C
(2) Heating ambient air temperature -3°C and leaving water temperature 65°C, capacity stated net of 1 defrost cycle per hour
Notes:
i) Refnet joints can be found on page 81
ii) Commissioning assistance should be included per hydrobox
iii) DHW cylinder required for hot water function
iv) See page 93 for accessories
94
Residential, Commercial and Industrial
£15,335.00
£5,773
£9,114
£312
£136
1 x EMRQ14
3 x EKHBRD016ACV1
3 x EKRP1AHT
1 x KHRQM64H
£16,644.00
£6,806
£9,390
£312
£136
Refrigeration
CVP96
REFRIGERATION
ZEAS97
Scotland
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
CVP
CVP is a compact, low noise system which integrates high and low temperature refrigeration
along with heating and cooling into one system. A total solution helping retailers save energy and
the environment.
Benefits
• Optimum efficiency: inverter driven outdoor units match
system output to the actual demand in order to reach
optimum efficiency under all conditions
•V
arious options: supports a wide range of refrigeration and
cooling units
• Save energy: by recovering the heat extracted from the
connected refrigeration appliances and using sophisticated
controls, energy savings of up to 50% can be reached
• Small footprint: along with reduced piping the small CVP is
ideal for densely populated urban areas
• Flexible: VRV (Variable Refrigerant Volume) technology for
flexible application range. Full range of VRV fan coils available
together with air curtains
• Minimal noise: low operating sound level
HEAT
RECOVERY
CVP
LRYEQ-AY1
-10°C
REFRIGERATION
Indoor units
Casing
Dimensions
Weight
Heat exchanger
Fan
Fan motor
Compressor
Operation range
Refrigerant
Refrigerant oil
Power supply
Voltage range
LRYEQ16AY1
Colour
HeightxWidthx Depth
Type
Type
Quantity
Air flow rate Cooling
Output
Drive
N° of compressors
Type
Piston displacement
Speed
Output
Starting method
Frequency ON/OFF
Evaporator
Cooling
Type
Charge
Control
Type
Charged volume
mm
kg
Nom.
m³/min
W
m³/h
rpm
W
Min.~Max.
Phase / Frequency / Voltage
Min.
Max.
°CDB
kg
l
Hz / V
%
%
Trade price
(1) Compressor 1 | (2) Compressor 2 | (3) Compressor 3 | (4) Factory charge of unit
96
-35°C
Residential, Commercial and Industrial
Ivory white (Munsell code: 5Y7.5/1)
1,680x1,240x765
370
Cross fin coil
Propeller fan
2
230
750
Direct drive
3
Hermetically sealed scroll compressor
13.34 / 10.53 / 10.53
6,300 / 2,900 / 2,900
2,500 / 3,600 / 4,500
Direct on line (inverter driven)
Less than 6 times/hour
-20 @ 0~10
R-410A
11.5
Electronic expansion valve
Daphne FVC68D
1.7 (1)
2.1 (2)
2.1 (3)
4.0 (4)
3~ / 50 / 380-415
-10
10
£14,015.00
ZEAS condensing units: a complete solution for
refrigeration applications
When you select a refrigeration condensing unit, you want premium performance with simple
installation and maintenance. That’s why you should specify Daikin ZEAS condensing units.
Compact yet powerful and extremely energy efficient, Daikin
ZEAS condensing units offer an industry-leading solution for all
kinds of installation projects.
ZEAS condensing units offer:
ZEAS is an adaptable and controllable solution for all kinds of
environments with fluctuating loads such as supermarkets, hotels,
restaurants, hospitals and florists, as well as food production
facilities such as cold storage, and blast coolers and freezers.
• Higher refrigeration capacity to power consumption ratio
compared with standard systems
• Compact system with reduced piping lengths
• COP of up to 3.0
• Energy efficient inverter control minimises CO2 emissions
Delivering all the benefits of inverter controlled VRV
technology for commercial refrigeration systems, ZEAS offers
a comprehensive product range suitable for low temperature
applications of 5.4 to 15.1 kW at -35/+32°C and medium
temperature applications of 12.2 to 37.0 kW at -10°C /+32°C.
• Utilises energy efficient R-410A refrigerant
Its small footprint and low sound levels offer installation flexibility,
so you can gain larger capacities even in small spaces. What’s
more, the ZEAS solution comes fully packaged and programmed,
with minimal pipe work required, so installation time and cost is
reduced. Plus you can depend on Daikin’s dedicated after-sales
support to help ensure that commissioning and maintenance go
without a hitch.
All in all, it’s a quality solution that delivers maximum refrigeration
capacity with minimal fuss.
Fan motor
Compressor
Operation range
Refrigerant
Refrigerant oil
Piping
connections
Power supply
Voltage range
Current
Current - 50Hz
LREQ5BY1
Nom.
Unit
Unit
Type
Type
Quantity
Air flow rate
Output
Drive
Type
Piston displacement
Speed
Output
Starting method
Evaporator
Ambient temp.
Type
Charge
Control
Type
Charged volume
Liquid
kW
mm
kg
H xW x D
Cooling
Nom.
m³/min
kW
m³/h
rpm
kW
Min.~Max.
Min.~Max.
°CDB
°C
kg
l
50m or less
50~130m
Gas
Phase/Frequency/Voltage
Min.
Max.
Nominal running
Compressor
current (RLA) - 50Hz
Starting current (MSC)
Minimum Ssc value
Minimum circuit amps (MCA)
Maximum fuse amps (MFA)
Total overcurrent amps (TOCA)
Full load amps (FLA) Fan motor
Cooling
Hz/V
%
%
A
LREQ6BY1
12.5
15.2
1,680x635x765
166
LREQ8BY1
LREQ10BY1
LREQ12BY1
19.8
23.8
1,680x930x765
242
Cross fin coil
Propeller fan
26.5
A
kVa
A
A
A
A
Trade price
1
171
13.7
74
655
19.3
LREQ20BY1
33.9
37.9
1,680x1,240x765
331
337
2
179
191
230
240
0.35
0.75
0.35 + 0.35
0.75+0.75
Direct drive
Hermetically sealed scroll compressor
Hermetically sealed scroll compressor (x2)
11.18
13.85
19.68
23.36
25.27
32.24
35.8
5,280
6,540
4,320+2,900
6,060+2,900
6,960+2,900 5,280+2,900+2,900 6,960+2,900+2,900
2.6
3.2
2.1 + 3.6
3.0 + 3.6
3.4 + 3.6
2.6 + 3.6 + 3.6 3.4 + 3.6 + 3.6
Direct on line (inverter driven)
Direct on line (inverter driven) (x2)
-45~10
-20~43
R-410A
5.2
7.9
11.5
Electronic expansion valve
Daphne FVC68D
1.7 / 2.5
1.7 / 2.5
1.7 / 2.1 / 3.0
1.7 / 2.1 / 3.0
1.7 / 2.1 / 3.0
1.7 / 2.1 / 4.0
1.7 / 2.1 / 4.0
ø 9.5 C1220T (Brazing connection)
ø 12.7 C1220T (Brazing connection)
ø 9.5 C1220T (Brazing connection)
ø 12.7 C1220T (Brazing connection)
ø 22.2 C1220T (Brazing connection)
ø 28.6 C1220T (Brazing connection)
ø 34.9 C1220T (Brazing connection)
3~/50/380-415
-10
10
7.1
9.2
5.3 + 7.5
7.4 + 7.9
9.8 + 8.3
7.0 + 8.2
9.5 + 8.4
+ 8.2
+ 8.4
95
102
LREQ15BY1
12.8
15
15.6
0.4
£7,105.00
£8,029.00
£8,855.00
75
84
899
22.0
25
31.5
0.9
1,097
24.0
£10,085.00
£11,570.00
761
31.4
945
35.0
40
48.3
0.4 + 0.4
0.7 + 0.7
£15,259.00
£17,322.00
*Operation conditions of outdoor unit: Te = -10°C, outdoor temperature +32°C, suction SH10°C
Price List 2014
97
REFRIGERATION
Outdoor unit
Cooling capacity*
Dimensions
Weight
Heat exchanger
Fan
Outdoor unit
LREQ30BY1
LREQ40BY1
System
Refrigerating
capacity
LREQ15BY1R x 2
67.8
27.8
30.4
25.6
(1,680x1,240x765) x 2
331 x 2
LREQ20BY1R x 2
75.8
29.6
34.0
27.6
(1,680x1,240x765) x 2
337 x 2
Power input
Dimensions
Weight
Heat exchanger
Compressor
Fan
Fan motor
Medium temperature
Low temperature
Medium temperature
Low temperature
Unit
H xW x D
Unit
Type
Type
Piston displacement
Speed
Output
Starting method
Type
Quantity
Air flow rate
Cooling
Output
Drive
Nom.
Nom.
Nom.
Nom.
Cross fin coil
Hermetically sealed scroll compressor
m³/h
rpm
W
Nom.
Starting current (MSC)
REFRIGERATION
Trade price
98
32.24 x 2
(5,280+2,900+2,900) x 2
(2.6+3.6+3.6) x 2
35.80 x 2
(6,960+2,900+2,900) x 2
Direct online (inverter driven)
Propeller fan
Sound pressure level
Nom.
Operation range
Evaporator
Cooling Min.~Max.
Ambient temperature
Min.~Max.
Refrigerant
Type
Charge
Control
Refrigerant oil
Type
Charged volume
Piping
Liquid
50m or less
connections
50~130m
Gas
50m or less
50~130m
Power supply
Phase/Frequency/Voltage
Current
Nominal running current (RLA) - 50Hz
Current - 50Hz
kW
kW
kW
kW
mm
kg
Residential, Commercial and Industrial
m³/min
W
2x2
230 x 2
(350 x 2) x 2
2x2
240 x 2
(750 x 2) x 2
Direct drive
dBA
°CDB
°C
65.0
66.0
-45~10
-20~43
R-410A
11.5 x 2
Electronic expansion valve
Daphne FVC68D
(1.7+ 2.1+2.1+ 4.0) x 2
kg
l
ø 19.05 C1220T (Brazing connection)
ø 41.28 C1220T (Brazing connection)
Hz/V
A
A
3~/50/380~415
(7.0/8.2/8.2) x 2
(9.5/8.4/8.4) x 2
109
115
£30,290.00
£34,416.00
Applied
100
Chilled Water Fan Coils
104
APPLIED
Water Chillers
Scotland
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
Air Cooled Water Chillers
Model
No
Nominal
Cooling
kW
Nominal
Heating
kW
Power
Supply
Trade
Price
Cooling Capacity:
Air Cooled Inverter Packaged Swing / Scroll Compressor –
R410a
EWAQ005ADVP
EWAQ006ADVP
EWAQ007ADVP
EWAQ009ACV3P
EWAQ010ACV3P
EWAQ011ACV3P
EWAQ009ACW1P
EWAQ011ACW1P
EWAQ013ACW1P
5.20
6.00
7.10
8.60
9.60
11.10
9.10
11.10
13.30
-
1-phase
1-phase
1-phase
1-phase
1-phase
1-phase
3-phase
3-phase
3-phase
£2,061.00
£2,259.00
£2,503.00
£2,856.00
£3,023.00
£3,249.00
£2,980.00
£3,276.00
£3,471.00
Air Cooled Inverter Packaged Scroll Compressor – R410a
EWAQ016BAWN
EWAQ021BAWN
EWAQ025BAWN
EWAQ032BAWN
EWAQ040BAWN
EWAQ050BAWN
EWAQ064BAWN
17.4
21.7
25.8
32.3
43.4
51.8
64.5
-
3 - phase
3 - phase
3 - phase
3 - phase
3 - phase
3 - phase
3 - phase
£4,714.00
£5,550.00
£6,260.00
£7,223.00
£9,552.00
£10,643.00
£12,290.00
Air cooled packaged scroll compressor – R407c
EUWAN5KBZW
EUWAN8KBZW
EUWAN10KBZW
EUWAN12KBZW
EUWAN16KBZW
EUWAN20KBZW
EUWAN24KBZW
11.30
17.90
22.50
26.50
34.60
46.60
55.30
-
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
£2,425.00
£3,598.00
£4,069.00
£4,278.00
£5,695.00
£7,200.00
£8,017.00
Air Cooled Packaged Scroll Compressor – R407c
c/w hydraulic pump and expansion vessel
EUWAP5KBZW
EUWAP8KBZW
EUWAP10KBZW
EUWAP12KBZW
EUWAP16KBZW
EUWAP20KBZW
EUWAP24KBZW
11.30
17.90
22.50
26.50
34.60
46.60
55.30
-
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
£2,795.00
£4,060.00
£4,563.00
£4,777.00
£6,112.00
£7,691.00
£8,532.00
Air Cooled Packaged Scroll Compressor – R407c
c/w hydraulic pump, expansion vessel and buffer tank
EUWAB5KBZW
EUWAB8KBZW
EUWAB10KBZW
EUWAB12KBZW
EUWAB16KBZW
EUWAB20KBZW
EUWAB24KBZW
11.30
17.90
22.50
26.50
34.60
46.60
55.30
-
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
£3,054.00
£4,378.00
£4,904.00
£5,126.00
£6,392.00
£8,018.00
£8,876.00
To Fit Model EWAQ-A
006
007
009
010
011
009
011
013
OP10
Evaporator Heater Tape
£276
£276
£276
£304
£304
£304
£304
£304
£304
To Fit Model EWAQ-BA
Part No
Description
016
021
025
032
040
050
064
UK57-BA
UK08B-BA
UK78-BA
UK79-BA
Evaporator Heater Tape
Chilled Water Down to -10
Low Lift Pump
High Lift Pump
£394
£292
£438
£642
£394
£292
£438
£642
£394
£292
£438
£642
£394
£292
£584
£642
£496
£394
£584
£875
£496
£394
£584
£875
£496
£394
£584
£875
To Fit Model EUWAN-KBZW
Part No
Description
OP10
OPHF
OPZH
OPZL
Evaporator Heater Tape
High Static Fan
Chilled Water Down to -5
Chilled Water Down to -10
Part No
Description
OP10
OPHP
OPHF
OPZH
OPZL
Evaporator Heater Tape
High Static Pump
High Static Fan
Chilled Water Down to -5
Chilled Water Down to -10
Description
OP10
OPHP
OPHF
OPZH
OPZL
Evaporator Heater Tape
High Static Pump
High Static Fan
Chilled Water Down to -5
Chilled Water Down to -10
Residential, Commercial and Industrial
5
8
10
12
16
20
24
£112
£17
£167
£167
£112
£40
£167
£167
£112
£40
£167
£167
£112
£40
£167
£167
£112
£82
£167
£167
£112
£82
£167
£167
£112
£82
£167
£167
To Fit Model EUWAP-KBZW
Part No
100
EWAQ-ACW1P
005
i)Please contact your local sales office for further information on
these products
iv)The EWAQ064BA delivery does not include offloading to kerbside.
Additional costs for delivery with a Hi-ab are available on request
EWAQ-ACV3P
Description
To Fit Model EUWAB-KBZW
iii) EWAQ -A series only operates in cooling down to ambients of +10°C
EWAQ-ADVP
Part No
Notes:
ii)Nominal cooling capacities are based on 35°C ambient,
chilled water @ 12/7°C
APPLIED
Fitted Options:
5
8
10
12
16
20
24
£225
£69
£17
£167
£167
£225
£69
£40
£167
£167
£225
£69
£40
£167
£167
£225
£69
£40
£167
£167
£225
£262
£82
£167
£167
£225
£262
£82
£167
£167
£225
£262
£82
£167
£167
5
8
10
12
16
20
24
£276
£69
£17
£167
£167
£276
£69
£40
£167
£167
£276
£69
£40
£167
£167
£276
£69
£40
£167
£167
£276
£262
£82
£167
£167
£276
£262
£82
£167
£167
£276
£262
£82
£167
£167
Air Cooled Heat Pump Water Chillers
Model
No
Nominal
Cooling
kW
Nominal
Heating
kW
Power
Supply
Trade
Price
Cooling Capacity:
Air Cooled Heat Pump Inverter Packaged
Swing / Scroll Compressor – R410a
EWYQ005ADVP
EWYQ006ADVP
EWYQ007ADVP
EWYQ009ACV3P
EWYQ010ACV3P
EWYQ011ACV3P
EWYQ009ACW1P
EWYQ011ACW1P
EWYQ013ACW1P
5.20
6.00
7.10
8.60
9.60
11.10
9.10
11.10
13.30
5.65
6.35
7.75
9.90
11.40
12.90
10.90
12.40
13.90
1-phase
1-phase
1-phase
1-phase
1-phase
1-phase
3-phase
3-phase
3-phase
£2,380.00
£2,571.00
£2,845.00
£3,288.00
£3,415.00
£3,460.00
£3,415.00
£3,706.00
£3,917.00
Air Cooled Heat Pump Inverter Packaged
Scroll Compressor – R410a
17.4
21.7
25.8
32.3
43.4
51.8
64.5
16.2
20.3
24.6
30.7
40.6
49.0
61.5
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
£5,421.00
£6,385.00
£7,202.00
£8,305.00
£10,985.00
£12,237.00
£14,135.00
Air Cooled Heat Pump Packaged Scroll Compressor – R407c
EUWYN5KBZW
EUWYN8KBZW
EUWYN10KBZW
EUWYN12KBZW
EUWYN16KBZW
EUWYN20KBZW
EUWYN24KBZW
9.10
17.10
21.00
25.00
34.20
40.00
50.00
11.90
18.50
24.00
27.00
37.00
46.00
54.00
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
£2,717.00
£4,181.00
£4,584.00
£4,860.00
£6,569.00
£7,966.00
£8,778.00
Air Cooled Heat Pump Packaged Scroll Compressor – R407c
c/w hydraulic pump and expansion vessel
EUWYP5KBZW
EUWYP8KBZW
EUWYP10KBZW
EUWYP12KBZW
EUWYP16KBZW
EUWYP20KBZW
EUWYP24KBZW
9.10
17.10
21.00
25.00
34.20
40.00
50.00
11.90
18.50
24.00
27.00
37.00
46.00
54.00
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
£3,094.00
£4,671.00
£5,089.00
£5,379.00
£7,005.00
£8,466.00
£9,291.00
Air Cooled Heat Pump Packaged Scroll Compressor – R407c
c/w hydraulic pump, expansion vessel and buffer tank
EUWYB5KBZW
EUWYB8KBZW
EUWYB10KBZW
EUWYB12KBZW
EUWYB16KBZW
EUWYB20KBZW
EUWYB24KBZW
9.10
17.10
21.00
25.00
34.20
40.00
50.00
11.90
18.50
24.00
27.00
37.00
46.00
54.00
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
£3,354.00
£4,809.00
£5,382.00
£5,625.00
£7,021.00
£8,802.00
£9,748.00
Notes:
i)Please contact your local sales office for further information on
these products
ii)Nominal cooling capacities are based on 35°C ambient,
chilled water @ 12/7°C
iii)Nominal heating capacities are based on 7°C db / 6°C wb ambient,
water @ 45 / 50°C
Fitted Options:
To Fit Model EWYQ-A
EWYQ-ADVP
EWYQ-ACV3P
EWYQ-ACW1P
Part No
Description
005
006
007
009
010
011
009
011
013
OP10
Evaporator Heater Tape
£276
£276
£276
£304
£304
£304
£304
£304
£304
To Fit Model EWYQ-BA
Part No
Description
016
021
025
032
040
050
064
UK57-BA
UK08B-BA
UK78-BA
UK79-BA
Evaporator Heater Tape
Chilled Water Down to -10
Low Lift Pump
High Lift Pump
£394
£292
£438
£642
£394
£292
£438
£642
£394
£292
£438
£642
£394
£292
£584
£642
£496
£394
£584
£875
£496
£394
£584
£875
£496
£394
£584
£875
To Fit Model EUWYN-KBZW
Part No
Description
OP10
OPHF
OPZH
OPZL
Evaporator Heater Tape
High Static Fan
Chilled Water Down to -5
Chilled Water Down to -10
5
8
10
12
16
20
24
£112
£17
£167
£167
£112
£40
£167
£167
£112
£40
£167
£167
£112
£40
£167
£167
£112
£82
£167
£167
£112
£82
£167
£167
£112
£82
£167
£167
To Fit Model EUWYP-KBZW
Part No
Description
OP10
OPHP
OPHF
OPZH
OPZL
Evaporator Heater Tape
High Static Pump
High Static Fan
Chilled Water Down to -5
Chilled Water Down to -10
5
8
10
12
16
20
24
£225
£69
£17
£167
£167
£225
£69
£40
£167
£167
£225
£69
£40
£167
£167
£225
£69
£40
£167
£167
£225
£262
£82
£167
£167
£225
£262
£82
£167
£167
£225
£262
£82
£167
£167
To Fit Model EUWYB-KBZW
Part No
Description
OP10
OPHP
OPHF
OPZH
OPZL
Evaporator Heater Tape
High Static Pump
High Static Fan
Chilled Water Down to -5
Chilled Water Down to -10
5
8
10
12
16
20
24
£276
£69
£17
£167
£167
£276
£69
£40
£167
£167
£276
£69
£40
£167
£167
£276
£69
£40
£167
£167
£276
£262
£82
£167
£167
£276
£262
£82
£167
£167
£276
£262
£82
£167
£167
APPLIED
EWYQ016BAWN
EWYQ021BAWN
EWYQ025BAWN
EWYQ032BAWN
EWYQ040BAWN
EWYQ050BAWN
EWYQ064BAWN
iv)EWYQ -A series only operates in cooling down to ambients of +10°C
v)The EWYQ064BA delivery does not include offloading to kerbside.
Additional costs for delivery with a Hi-ab are available on request
Price List 2014
101
Water Cooled Chillers
Model
No
Nominal
Cooling
kW
Nominal
Heating
kW
Power
Supply
Trade
Price
Cooling Capacity:
Water Cooled Packaged Scroll Compressor – R407C
EWWP014KBW1N
EWWP022KBW1N
EWWP028KBW1N
EWWP035KBW1N
EWWP045KBW1N
EWWP055KBW1N
EWWP065KBW1N
12.90
21.40
27.80
32.30
42.80
55.70
64.70
-
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
£2,909.00
£3,439.00
£3,951.00
£4,598.00
£5,664.00
£6,326.00
£7,065.00
Notes:
i)Please contact your local sales office for further information on
these products
ii)Nominal cooling capacities are based on chilled water @ 12/7°C,
condenser water @ 30/35°C
Fitted Options:
To Fit Model EWWP-KAW1N
Part No
Description
014
022
028
035
045
055
065
OPZH
OPZL
Chilled Water Down to -5
Chilled Water Down to -10
£167
£167
£167
£167
£167
£167
£167
£167
£167
£167
£167
£167
£167
£167
Condenserless Chillers
Model
No
Nominal
Cooling
kW
Nominal
Heating
kW
Power
Supply
Trade
Price
Cooling Capacity:
Condenserless Packaged Scroll Compressor – R407C
EWLP012KBW1N
EWLP020KBW1N
EWLP026KBW1N
EWLP030KBW1N
EWLP040KBW1N
EWLP055KBW1N
EWLP065KBW1N
12.10
20.00
26.80
31.20
40.00
53.70
62.40
-
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
POA
POA
POA
POA
POA
POA
POA
Notes:
i)Please contact your local sales office for further information on
these products
APPLIED
ii)Nominal cooling capacities are based on chilled water @ 12/7°C,
condensing temperature @ 45°C, liquid temperature @40°C
Fitted Options:
To Fit Model EWLP-KAW1N
102
Residential, Commercial and Industrial
Part No
Description
012
020
026
030
040
055
065
OPZH
OPZL
Chilled Water Down to -5
Chilled Water Down to -10
POA
POA
POA
POA
POA
POA
POA
POA
POA
POA
POA
POA
POA
POA
Applied Systems Kit Options
Loose Accessory Options:
Description
Trade Price
Digital Pressure gauges - EWAQ/EWYQ-BA
External control adaptor Low noise & demand limit - EWAQ/EWYQ-BA
HYDRAULIC MODULE -Normal static + anti-freeze protection - EWWP014~022/EWLP012~020
HYDRAULIC MODULE-High static + anti-freeze protection - EWWP014~022/EWLP012~020
HYDRAULIC MODULE-Normal static + anti-freeze protection - EWWP028~035/EWLP026~030
HYDRAULIC MODULE-High static + anti-freeze protection - EWWP028~035/EWLP026~030
HYDRAULIC MODULE-Normal static + anti-freeze protection - EWWP045~065/EWLP040~065
HYDRAULIC MODULE-High static + anti-freeze protection - EWWP045~065/EWLP040~065
Address card for connection to BMS - EUWA/Y(N,P,B)5-24KBZW,EWWP,EWLP (note not available on the modular EWWP)
Remote Control- EUWA/Y(N,P,B)5-24KBZW,EWWP,EWLP (needs EKAC10C)
Buffertank 200I - EUWA/Y5-24KBZW
Gauges kit 10/12Hp-units - EUWA/Y10-12KBZW
Gauges kit 16Hp-units - EUWA/Y16 KBZW
Gauges kit 20/24Hp-units - EUWA/Y20-24KBZW
Gauges kit 5/8Hp-units - EUWA/Y5-8KBZW
Low noise operation EWLP012~EWWP14
Low noise operation EWLP02~030, EWWP22-35
Low noise operation EWLP040~065, EWWP45-65
Digital I/O PCB - EWAQ / EWYQ - AC
Demand PCB / Inputs - EWAQ/EWYQ-BA (2 x on size 40/50/64)
Remote user interface (in parallel) - EWAQ/EWYQ-BA
MODBUS Interface - EWAQ/EWYQ-BA
£268.00
£221.00
£1,668.00
£1,775.00
£1,775.00
£1,848.00
£1,991.00
£1,991.00
£86.00
£163.00
£1,097.00
£167.00
£268.00
£268.00
£167.00
£155.00
£155.00
£310.00
£104.00
£107.00
£161.00
£205.00
APPLIED
Model
BHGP26A1
DTA104A62
EHMC10A10
EHMC10A80
EHMC15A10
EHMC15A80
EHMC30A10
EHMC30A80
EKAC10C
EKRUMCA
EKBT
EKGAU10/12KA
EKGAU16KA
EKGAU20/24KA
EKGAU5/8KA
EKLS1
EKLS2
EKLS2 X 2
EKRP1HBA
EKRP1AHT
EKRUAHTB
RTD-W
Price List 2014
103
Fan Coil Units
APPLIED
Daikin’s fan coil range are manufactured in Europe to the same high standard,
high quality and reliability as their DX counterparts.
An extensive range of control and valve options are available to complement
these quiet and fashionable units.
Capacity conditions
EUROVENT conditions
Cooling
27°C db / 19°C wb - Entering water 7°C - Leaving water 12°C
Heating 4 Pipe
20°C db - Entering water 70°C - Leaving water 60°C
Heating 2 Pipe
20°C db - Entering water 50°C - Flow rate as in cooling mode
104
Residential, Commercial and Industrial
TYPICAL UK cooling conditions
22°C db / 16.0°C wb - Entering water 7°C - Leaving water 12°C
0 Pa External Static Pressure
0% Glycol
FWP & FWD Ducted FCU - Above capacities are based on 30 Pa
External Static Pressure
FWS Uncased - Based on 20 pa external static
New BLDC (Brushless Direct Current)
Inverter Driven Floor Standing Fan Coil Units
Cased Low Wall Mount Type 2-pipe
Capacity
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High/Low
High/Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
FWZ06AT
FWZ08AT
2.57
4.96
6.4
226
987
564
25
70/28
62/20
15
1/2
3.23
6.32
7.51
226
1194
564
31
64/28
56/20
20
1/2
5.11
10.08
11.18
251
1404
564
41
71/28
63/20
27.66
3/4
1ph
Cased Low Wall Mount Type 4-pipe
Dimensions
FWZ03AT
1.39
2.64
3.47
226
774
564
20
62/28
54/20
9.33
1/2
Power Supply
Trade Fan Coil Price
Capacity
FWZ02AT
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High/Low
High/Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
£267.00
£283.00
£327.00
£407.00
FWZ02AF
FWZ03AF
FWZ06AF
FWZ08AF
1.39
2.64
2.46
226
774
564
21
62/28
54/20
9.33
1/2
2.57
4.96
4.19
226
987
564
26
70/28
62/20
15
1/2
3.23
6.32
6.45
226
1194
564
33
64/28
56/20
20
1/2
5.11
10.08
10.06
251
1404
564
44
71/28
63/20
27.66
3/4
£303.00
£366.00
£442.00
FWR02AT
FWR03AT
FWR06AT
FWR08AT
1.39
2.64
3.47
226
774
564
21
62/28
54/20
9.33
1/2
2.57
4.96
6.4
226
987
564
27
70/28
62/20
15
1/2
3.23
6.32
7.51
226
1194
564
33
64/28
56/20
20
1/2
5.11
10.08
11.18
251
1404
564
44
71/28
63/20
27.66
3/4
Power Supply
1ph
Trade Fan Coil Price
£291.00
New BLDC (Brushless Direct Current)
Inverter Driven Flexi Fan Coil Units
Cased Flexi Type 2-pipe
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High/Low
High/Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
Power Supply
1ph
Trade Fan Coil Price
Cased Flexi Type 4-pipe
Capacity
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
Trade Fan Coil Price
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High/Low
High/Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
£280.00
£301.00
£349.00
£445.00
FWR02AF
FWR03AF
FWR06AF
FWR08AF
1.39
2.64
2.46
226
774
564
22
62/28
54/20
9.33
1/2
2.57
4.96
4.19
226
987
564
28
70/28
62/20
15
1/2
3.23
6.32
6.45
226
1194
564
35
64/28
56/20
20
1/2
5.11
10.08
10.06
251
1404
564
46
71/28
63/20
27.66
3/4
£388.00
£492.00
Power Supply
APPLIED
Capacity
1ph
£305.00
£329.00
Price List 2014
105
New BLDC (Brushless Direct Current)
Inverter Driven Low Static Concealed Flexi Fan Coil Units
Concealed Flexi Type 2-pipe
Capacity
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High/Low
High/Low
High
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
FWS06AT
FWS08AT
2.02
4.96
6.4
224
794
535
19
70/28
62/20
15
1/2
2.52
6.32
7.51
224
1004
535
23
64/28
56/20
20
1/2
3.99
10.08
11.18
249
1214
535
32
71/28
63/20
27.66
3/4
1ph
Concealed Flexi Type 4-pipe
Dimensions
FWS03AT
1.08
2.64
3.47
224
584
535
15
62/28
54/20
9.33
1/2
Power Supply
Trade Fan Coil Price
Capacity
FWS02AT
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High/Low
High/Low
High
£239.00
£257.00
£293.00
£366.00
FWS02AF
FWS03AF
FWS06AF
FWS08AF
1.08
2.64
2.46
224
584
535
16
62/28
54/20
9.33
1/2
2.02
4.96
4.19
224
794
535
20
70/28
62/20
15
1/2
2.52
6.32
6.45
224
1004
535
25
64/28
56/20
20
1/2
3.99
10.08
10.06
249
1214
535
34
71/28
63/20
27.66
3/4
£329.00
£412.00
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
Power Supply
1ph
Trade Fan Coil Price
£265.00
£287.00
Floor Standing and Flexi Fan Coil Unit Accessories
Loose Accessory Options:
FWZ,FWR,FWS
2-pipe 3-way valve kits c/w lockshields
4-pipe 3-way valve kits c/w lockshields
Vertical drainpan
Horizontal drainpan
Advanced Plus Electronic Controller
On board installation kit
(FWZ & FWR - Low Wall Mounted Only)
APPLIED
Reurn Air Sensor
106
Residential, Commercial and Industrial
Notes:
02-03
06
08
E2MV03A6
£121.00
E4MV03A6
£217.00
E2MV06A6
£121.00
E4MV06A6
£217.00
EDPVB6
£3.00
EDPHB6
£3.00
FWEC3A
£114.00
FWECKA
£11.00
FWTSKA
£8.00
E2MV10A6
£128.00
E4MV10A6
£227.00
FWEC3A can operate up to 247 fan coils as
master slave control, plus weekly schedule
timer, proportional valve control and 2 digital
outputs (1 per fan coil required)
Please note that
i)Each controller version includes the
water probe
ii)The on board installation kit includes a
remote air probe (If installed the internal
fan coil robe is disabled)
iii)The FWEC3A can operate up to 247
fan coils as master slave control, plus
weekly schedule timer, proportional valve
control and 2 digital outputs (1 per fan
coil required).
New BLDC (Brushless Direct Current)
Inverter Driven Medium Static Ducted Fan Coil Units
Concealed Ducted Type 2-pipe
Capacity
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High/Low
High/Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
FWP02-AT
FWP03-AT
FWP04-AT
FWP05-AT
FWP06-AT
FWP07-AT
1.34
2.61
5.47
239
1039
609
24
56/40
44/24
6.66
3/4
1.67
3.14
6.01
239
1039
609
26
56/40
44/24
6.66
3/4
2.03
3.49
6.47
239
1039
609
28
56/40
44/24
6.66
3/4
2.5
5.08
10.31
239
1389
609
33
61/39
50/27
13.33
3/4
2.77
5.45
11.39
239
1389
609
35
61/39
50/27
13.33
3/4
3.47
6.47
12.28
239
1389
609
38
61/39
50/27
13.33
3/4
Power Supply
1ph
Trade Fan Coil Price - Naked - No Valve
FWP02-ATN
FWP03-ATN
FWP04-ATN
FWP05-ATN
FWP06-ATN
FWP07-ATN
Trade Fan Coil Price- Complet with 3 - way valve fitted
£344.00
FWP02-ATV
£359.00
FWP03-ATV
£373.00
FWP04-ATV
£438.00
FWP05-ATV
£443.00
FWP06-ATV
£472.00
FWP07-ATV
£422.00
£436.00
£450.00
£514.00
£519.00
£549.00
Please note if you require a 4 pipe fan coil please purchase additional heat exhanger as shown below
FWP
Additional Heat exchanger (4 Pipe)
nominal heating cap 3.2kW
Additional Heat exchanger (4 Pipe)
nominal heating cap 6.1kW
2-way valve cooling coil
3-way valve add.h/e
2-way valve add.h/e
Advanced Plus Electronic Controller
Reurn Air Sensor
Notes:
02 - 04
05 - 07
EAH04A6
£89.00
-
EAH07A6
£104.00
E2MV207A6
£51.00
E2MV307A6
£91.00
E2MV207A6
£51.00
FWEC3A
£114.00
FWTSKA
£8.00
F WEC3A can operate up to 247 fan coils as
master slave control, plus weekly schedule
timer, proportional valve control and 2 digital
outputs (1 per fan coil required)
Please note that:
i)Each controller version includes the
water probe
ii)The FWEC3A can operate up to 247
fan coils as master slave control, plus
weekly schedule timer, proportional valve
control and 2 digital outputs (1 per fan
coil required).
APPLIED
Loose Accessory Options:
Price List 2014
107
High Static Ducted Fan Coil Units
Concealed Ducted Type 2-pipe
Capacity
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High / Low
High / Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
Concealed Ducted Type 4-pipe
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
FWD06AT
FWD08AT
FWD10AT
FWD12AT
FWD16AT
FWD18AT
2.15
3.9
4.05
280
754
559
33
66/54
56/46
13.33
3/4
3.48
6.2
7.71
280
964
559
41
69/59
61/51
20.83
3/4
4.44
7.8
9.43
280
1174
559
47
72/62
64/54
26.67
3/4
4.92
8.82
10.79
280
1174
559
49
72/62
64/54
26.67
3/4
1ph
7.21
11.9
14.45
352
1174
718
65
74/60
66/52
36.67
1
8.96
16.4
19.81
352
1384
718
77
78/69
70/61
50
1
9.91
18.3
21.92
352
1384
718
80
78/69
70/61
50
1
£270.00
£355.00
£415.00
£462.00
£574.00
£735.00
£808.00
FWD04AF
FWD06AF
FWD08AF
FWD10AF
FWD12AF
FWD16AF
FWD18AF
2.15
3.9
4.05
280
754
559
35
66/54
56/46
13.33
3/4
3.48
6.2
7.71
280
964
559
43
69/59
61/51
20.83
3/4
4.44
7.8
9.43
280
1174
559
50
72/62
64/54
26.67
3/4
4.92
8.82
10.79
280
1174
559
52
72/62
64/54
26.67
3/4
1ph
7.21
11.9
14.45
352
1174
718
71
74/60
66/52
36.67
1
8.96
16.4
19.81
352
1384
718
83
78/69
70/61
50
1
9.91
18.3
21.92
352
1384
718
86
78/69
70/61
50
1
£316.00
£413.00
£482.00
£545.00
£672.00
£853.00
£935.00
Power Supply
Trade Fan Coil Price
Capacity
FWD04AT
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High / Low
High / Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
Power Supply
Trade Fan Coil Price
Notes:
Loose Accessory Options:
FWD
4
2-pipe 3-way valve
4-pipe 3-way valve
Vertical Drain pan
Horizontal Drain Pan
Master slave interface
Power interface (S)
Standard Electronic Controller
Advanced Electronic Controller
Advanced Plus Electronic Controller
APPLIED
Return Air Sensor
108
Residential, Commercial and Industrial
ED2MV04A6
£128.00
ED4MV04A6
£244.00
6
8 -10
ED2MV10A6
£128.00
ED4MV10A6
£244.00
EDDPV10A6
£11.00
EDDPH10A6
£13.00
EPIMSA6
£84.00
EPIB6
£84.00
FWEC1A
£65.00
FWEC2A
£82.00
FWEC3A
£114.00
FWTSKA
£8.00
12
16 -18
ED2MV12A6
ED2MV18A6
£128.00
£133.00
2x ED2MV12A6 2 x ED2MV18A6
£256.00
£266.00
EDDPV18A6
£11.00
EDDPH18A6
£13.00
-
F WEC1A is designed as an individual unit
controller. Power interface EPIB6 is required
for unit size 16 and 18 can operate up to
4 fan coils by adding a EPIMSA6.
If using this controller to operate up to 4
fan coil units by adding a EPIMSA6 you will
require a EPIB6 power interface for unit
size 12,16,18.
FWEC2A can operate up to 247 fan coils as
master slave control ( 1 per fan coil required).
Power interface EPIB6 is required for each
unit size 16 and 18.
FWEC3A can operate up to 247 fan coils
as master slave control, plus weekly
schedule timer, proportional valve control
(by others) and 2 digital outputs ( 1 per fan
coil required).
Please note that:
i)Each controller version includes the
water probe.
600 Sq Cassette Fan Coil Units
600sq Cassette Type 2-pipe c/w Decoration Panel BYFQ60B
Capacity
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High / Low
High / Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
600sq Cassette Type 4-pipe c/w Decoration Panel BYFQ60B
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
FWF03BT
FWF04BT
FWF05BT
1.20
2
2.9
260
575
575
19
44/36
31/26
7.9
1.9
3.2
4
260
575
575
19
44/36
31/26
7.9
2.5
4.2
5.4
260
575
575
19
50/36
40/26
11.2
3.1
5.2
6.7
260
575
575
19
55/42
45/30
14.9
3/4 “ BSP Female
1 ph
Power Supply
Trade Fan Coil Price
Capacity
FWF02BT
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High / Low
High / Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
£509.00
£535.00
£565.00
£603.00
FWF02BF
FWF03BF
FWF04BF
FWF05BF
1.10
2
3.9
260
575
575
19
44/36
31/26
7.9
1.6
2.7
3.8
260
575
575
20
44/36
31/26
7.2
2
3.5
4.9
260
575
575
20
50/36
40/26
10.4
2.5
4.5
6.1
260
575
575
20
55/42
45/30
13.9
3/4 “ BSP Female
1 ph
Power Supply
Trade Fan Coil Price
£541.00
£565.00
£603.00
£637.00
FWC06BT
FWC07BT
FWC08BT
FWC09BT
3.30
5.8
8
288
840
840
26
43/31
29/21
17.7
4.1
6.8
8.9
288
840
840
26
47/33
33/22
20.6
4.3
7.7
10.6
288
840
840
26
53/36
39/24
25.4
4.8
8.7
12.1
288
840
840
26
57/40
43/28
30.8
Cassette Fan Coil Units
Capacity
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High / Low
High / Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
Trade Fan Coil Price
Cassette Type 4-pipe c/w Decoration Panel BYCQ140C
Capacity
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
Trade Fan Coil Price
3/4 “ BSP Female
1 ph
Power Supply
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High / Low
High / Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
£621.00
£637.00
£653.00
£681.00
FWC06BF
FWC07BF
FWC08BF
FWC09BF
3.30
5.8
7.5
288
840
840
29
43/31
29/21
17.1
4
6.6
8.4
288
840
840
29
47/33
33/22
19.9
4.3
7.6
9.7
288
840
840
29
53/36
39/24
24.6
4.8
8.7
11
288
840
840
29
57/40
43/28
29
£691.00
£708.00
APPLIED
Cassette Type 2-pipe c/w Decoration Panel BYCQ140C
3/4 “ BSP Female
1 ph
Power Supply
£649.00
£673.00
Price List 2014
109
Cassette Accessories
Loose Accessory Options:
Notes:
FWF/FWC
FWF/FWC
FWC only
FWC only
Remote wired controller (requires KJB212A)
BRC315D
£67.00
DCS601C51
£1,641.00
KRP4A53
£67.00
KRP4A53/UK.FB2
£92.00
KRP2A52
£177.00
KRP2A52/UK.FB2
£202.00
EKFCMBCB
£55.00
EKMV2C09B
£58.00
EKMV3C09B
£64.00
EKRP1C11
£100.00
Wireless remote control heat pump
BRC7FA532F
£152.00
BRC7F533F
£152.00
KRCS01-4
£47.00
KRP1H98
£37.00
Intelligent touch controller
Unit/Group adapter pcb
Unit/Group adapter pcb complete with
installation box
System adaptor pcb
System adaptor pcb complete with
installation box
Optional pcb for connection to ModBus
2-Way on / off valve kit
3-Way on / off valve kit
Valve control PCB
Wireless remote control cooling only
Remote air sensor
Installation box for an EKRP1C11 valve PCB
FWF only
FWF only
Wireless remote control heat pump
BRC7E530
£121.00
BRC7E531
£121.00
KRCS01-1
£46.00
EKRORO
£16.00
KRP1BA101
£43.00
Wireless remote control cooling only
System adaptor pcb
Remote on/off control interface kit
Installation box for an EKRP1C11 valve PCB
i)FWF and FWC Cassette Fan Coil prices
include decoration panel
ii)It is not possible to use Intelligent Touch
control for combination with both VRV
and water based fan coils
FWF-Valve control requirements
2 pipe unit: 1 x valve kit + 1 x installation
box for PCB KRP1BA101 + 1 x valve control
PCB EKRP1C11
4 pipe unit: 2 x valve kit + 1 x installation
box for PCB KRP1BA101 + 1 x valve control
PCB EKRP1C11
FWC-Valve control requirements
2 pipe unit: 1 x valve kit + 1 x installation
box for PCB KRP1H98 + 1 x valve control
PCB EKRP1C11
4 pipe unit: 2 x valve kit + 1 x installation
box for PCB KRP1H98 + 1 x valve control
PCB EKRP1C11
Wall Mounted Fan Coil Units
Cased High Wall Mount Type 2-pipe
Capacity
Dimensions
APPLIED
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High / Low
High / Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
FWT02CT
FWT03CT
FWT04CT
FWT05CT
FWT06CT
1.59
2.43
3.22
288
800
206
10
45/36
34/25
7.36
1/2
1.67
2.7
3.52
288
800
206
10
48/39
35/25
7.93
1/2
2.1
3.31
4.4
288
800
206
10
55/45
42/32
10.48
1/2
1ph
2.9
4.54
6.01
310
1065
224
15
55/47
42/34
14.43
1/2
3.41
5.28
5.26
310
1065
224
15
59/51
42/39
17.55
1/2
£196.00
£204.00
£234.00
£283.00
£301.00
Power Supply
Trade Fan Coil Price
Loose Accessory Options:
FWT
FWT
Standard wired remote controller
Simplified wired remote controller
Wireless controller for heat pump
110
Notes:
Residential, Commercial and Industrial
MERCA
£76.00
SRC-HPA
£39.00
WRC-HPB
£15.00
i)FWT fan coils are optimised for valveless
control in cooling. We would recommend
that a valve is fitted if being used for
heating only and for more precise control
in cooling.
ii)We would recommend the field supply of
a 240V - 4 port 3 way valve complete with
240V actuator.
Miscellaneous
Schematics & Malfunction Codes
112
Delivery Information
114
Goods Returns Procedure
115
Field Quality Service
116
Warranty117
Training118
Scotland
Region
0845 641 9330
120
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
MISCELLANEOUS
Terms & Conditions
Wiring Diagram
Split & Sky Air Interconnecting Wiring
*
* Except RX50-71, RXS42-71 & RXG50 which require
2.5mm 4 core interconnecting wiring
MISCELLANEOUS
Wiring Adaptor for External Control
KRP4A51-52-53-54
112
Residential, Commercial and Industrial
Wiring Adaptor for External Control
KRP4A51-52-53-54
Overall Malfunction Display on Daikin LCD Controller
2nd
A
3
4
5
6
7
8
Protection
Device Activated Faulty Indoor PCB
(General)
0
Abnormal Drain
H2O Level
Abnormal Heat
Exchanger 1
Temperature
Abnormal Heat
Exchanger 2
Temperature
Fan Motor
Overload & Over
Current Lock
Air Swing Motor
Lock
AC Input Over
Current
Outdoor
2
Malfunction
of Liquid Pipe
Thermisor for
Heat Exchanger
C
Flow Switch
Abnormality
Failure of
Transmission
Between Indoor
Unit & Sub PCB’s
Faulty Drain H2O
Level Sensor
System
Malfunction
Fan Motor OL/OC,
Air Swing Motor
of Gas Pipe
Lock Sensor Incorrect
Lock Faulty Sensor
Thermisor for
combination
System
Heat Exchanger
Fandrive/Set
Faulty AC Input
Current Sensor
System.
E
Safety Device
Activation
(General)
Faulty Outdoor
PCB
Activation of High Activation of Low
Activation of
Compressor Over Fan Motor OL.OC.
Pressure Switch Pressure Switch Inverter Compressor
Current Lock
Lock
(HPS)
(LPS)
Motor Overload
OC of Inverter
Compressor
Activation Safety Activation Safety
Faulty Discharge
Device (Syst.
Device (Syst.
Pipe Temperature
No.1)
No.2)
F
Voltage & Current
Sensor Failure
Faulty Air
Temperature
Sensor System
Damper Fail
Faulty Power
Supply Sensor
System
Faulty High
Pressure Switch
(HPS)
Faulty Low
Compressor Motor Compressor Motor Fan Motor OL OC,
Pressure Switch Faulty OL. Sensor OC. Lock Faulty Faulty Lock Sensor
(LPS)
System
Sensor System
System
J
Faulty Refrigerant
Temperature
Sensor System
Malfunction of
Pressure Sensor
Faulty Current
Sensor System
Malfunction of
Discharge Pipe
Thermistor
Faulty LP Equiv.
Sat. Temperature
Sensor System
L
Faulty Inverter
System
Malfunction of
Inverter PCB
Gas Short. ice
System
U
Shortage of
Refrigerant
Malfunction of
Suction Pipe
Thermistor
Faulty Heat
Exchanger 1
Temperature
Sensor System
Abnormal
Abnormal
Inverter
Inverter
Temperature Rise
Temperature Rise
Instantaneous OC Instantaneous OC
Radiation Fin
In Switch Box
(DC output)
(AC output)
Thermistor
Missing Phase.
Unbalanced
Power Supply
Auto charge
Stopped At Step 5
BS4 Not Pushed
Malfunction of
Thermistor in
Switch Box
Faulty Radiant
Fin Temperature
Sensor System
Faulty DC Current
Sensor System
Faulty AC or DC
Output Current
Sensor System
Reversed or Open
Phase Connected
Faulty Power
Supply Voltage
System
Faulty
Transmission
or Test Run Not
Executed
Faulty
Transmission
Indoor ↔
Outdoor Units
Faulty
Transmission.
Indoor Unit ↔
Remote Control
Faulty
Transmission
Indoor Units
(Master ↔
Slave)
Malfunction
of Centralised
Remote Controller
PCB
M
HRV External
6 Protection Device
Activated
Faulty PCB
Faulty Heat
Exchanger 2
Temperature
Sensor System
Malfunction
of Total Input
Current Sensor
9
A
Backup Heater
Faulty Electronic
Thermal Protector
Expansion Valve
Activated
Malfunction
of Suction Air
Thermisor
Malfunction of
Humidity Sensor
System
Expansion Valve
faulty In BSVQ-P
Abnormal
discharge
pressure
Abnormal suction
pressure
Abnormal Oil
Pressure
Abnormal Oil
Surface Level
Abnormal High
Oil Temperature
Faulty AC Input
Power Sensor
System
Malfunction
of Outdoor Air
Thermistor
Malfunction of
Discharge Air
Thermistor
Malfunction of
Domestic Hot
Water Tank
Thermistor
Faulty Liquid
Pipe Temperature
Sensor System
Faulty Gas Pipe
Temperature
Sensor System
Faulty Discharge
Pressure Sensor
System
Malfunction of
Faulty Suction
Faulty Oil Pressure Oil Level Sensor
Pressure Sensor
Sensor System or Heating HeatX
System
thermistor
Inverter
Compressor OC
Detection
Compressor Stall
Prevention
Faulty power
transistor
Autocharge
Should Be
Restarted
Autocharge
Judgement:
Finished OK
Leak Test not poss
Replace Charge
w/o input add
Cylinder “Slave 1”
charge
Faulty Capacity
Setting Plug
(Outdoor)
Faulty On Site
Setting
Address
Duplication or
Incorrect Setting
Faulty
Transmission
Indoor Unit
↔ Centralised
Control
Incorrect Wiring/
Indoor/Outdoor
Piping (Wiring/
unit address not
Piping Connection
entered
Error)
Fault
communication
to/from
peripheral
equipment
Improper Comb.
of Optional
Controllers for
Centralised
Control
Address
Duplication /
Improper Setting
Simplified
Remote Control
Malfunction HRV
Replace HighEfficiency Filter
Malfunction of
Pump Interlock
Inlet Water
Temperature
Thermistor
Outlet Water
Temperature
Thermistor
System no. 1
Malfunction
of Refrigerant
Thermistor
System no. 2
Malfunction
of Refrigerant
Thermistor
System no. 1
Malfunction of
Heat Exchange
Thermistor
System no. 2
Malfunction of
Heat Exchange
Thermistor
System no. 1
Malfunction of
Discharge Pipe
Thermistor
Malfunction of
Transmission
HRV ↔ Indoor
Fan Units
System no. 1
Malfunction
of Fan Inverter
System
System no. 2
Malfunction
of Fan Inverter
System
System no. 2
Low Water
System no. 2
9 Volume Detection Defect of EEV Coil Defect of Suction
Pipe Thermistor
Defect of Thermal
Storage Unit
System no. 2
Malfunction of
Discharge Pipe
Thermistor
Heat Exchanger
Freeze Up
Thermal Storage
Unit Brine
Pump O/C
Thermal Storage
Brine Tank Low
Water Level
Faulty Oil
Temperature
Sensor System
Auto charge
Almost finished
System no. 2
Malfunction
of Compressor
Current Sensor
8
Float switch (local
supply) Open (if
Mode 2-26)
Replace Charge Replace Charge
Cylinder “Master” Cylinder “Slave 2”
System no. 1
System no. 2
System no. 2
System no. 2
Malfunction of Fan Malfunction of Fan
Malfunction of LP Malfunction of HP
Interlock (defect of Interlock (defect of
sensor
sensor
relay contact)
relay contact)
System no. 2
Activation of LP
Switch
Faulty drain H2O
Heat Storage Unit
level Sensor
Alarm
System
Activation Of
Local Safety
Device
Malfunction of
Transmission
Between Control
& Inverter PCB
Humidifier
Element
Replacement
System no. 2
Activation of HP
Switch
Malfunction
of Thermistor
in Remote
Controller
Pump OC. Lock
Malfunction of
Damper System
HRV
System no.2
Fan Motor Over
Current
J
Faulty Capacity
Setting Plug
(Indoor)
Faulty Heat
Storage Unit
Malfunction of
Thermistor for
Outdoor Air HRV
System no. 2
Compressor Over
Current
H
Faulty Or Dirty
Dust Collector
Faulty Drain H2O
Level System
Malfucntion of
Thermistor for
Indoor Air HRV
System no. 2
Compressor
Overheat
F
Malfunction of
Faulty Electronic
Abnormal Water
4-Way Valve Cool/
Expansion Valve
Temperature
Heat Switching
Abnormal Ozone
Faulty dirt sensor
Concentration
7
E
Insufficient Water
Faulty Humidifier
Supply
Faulty High
Pressure Switch
Malfunction of
Malfunction of
Faulty
Transmission
Transmission
Transmission
between Indoor/
between Outdoor between Remote
Outdoor Unit in
Units
Controllers
Same System
Malfunction of
Transmission ↔
Optional Controller
for Centralised
Control
Malfunction of
Discharge Air
Thermistor
C
Booster Heater
Thermal
Protector
Malfunction
of Switch Box
Thermistor
Abnormal
High Pressure
or Refrigerant
Overcharge
Malfunction of
Suction Pipe
Thermistor
H
P thermal stor. Eqp.
Other
1
Malfunction of
Leaving Water
Temperature
Thermistor
Replace the
Deodorising
Catalyst
Door Switch
Open HRV
Flow Failure
Insufficient Water
Flow
System no. 1
System no. 1
Malfunction of Suction Malfunction of Suction
Pipe Thermistor 1 for Pipe Thermistor 2 for
Heating
Heating
Outlet Water
Temperature
Thermistor
MISCELLANEOUS
Indoor
1st
System no. 2
System no. 2
Malfunction of Suction Malfunction of Suction
Pipe Thermistor 1 for Pipe Thermistor 2 for
Heating
Heating
Caution: Some displayed malfunction codes may have another meaning. Consult the relevant service manual for details.
Price List 2014
113
Delivery Information
Material Code
Description
Standard Delivery Mon - Fri 8:00am to 17:00pm (excluding Spares)
Standard
Standard delivery
delivery
Cost
Order processing deadline
Notes:
Included
Order processed by 14:00 Day 1 Delivery Day 2
•W
eekday = Monday to Friday
8:00am to 17:00pm
• Standard delivery vehicle is 17.5
ton lorry or smaller with tail lift
Standard Hours (8:00am - 17:00pm) Timed Deliveries (excluding Spares)
UK.DLVWIN1
8:00am - 13:00hrs weekdays
£50.00
UK.DLVWIN2
12:30 - 17:00hrs weekdays
£45.00
UK.TDN_30min
Time specific 30 min window during standard hours
£220.00
Order processed by 14:00 Day 1 Delivery Day 2
Order processed by 14:00 Day 1 Delivery Day 2
Order processed by 14:00 Day 1 Delivery Day 2
Outside Standard
UK.TDO_30min
Time specific 30 min window outside standard hours
UK.RUSH
Same day delivery (geographical restrictions apply)
Order processed by 14:00 Day 1 Delivery Day 2
Order processed 11:00
£290.00
£220.00
Weekend Deliveries excluding Spares
UK.TDO_30min
Time specific 30 min window outside standard hours
£290.00
Order processed by 14:00 Day 1 Delivery Day 3 or 4 (as requested)
UK.SAT_Courrier Less than 15KG
£35.00
Order processed by 14:00 Day 1 Delivery Day 2
UK.SAT_Sub
Greater than 15KG
£110.00
Order processed Day 1 Delivery Day 3
Public holidays - request for deliveries on public holidays are considered on an individual basis
Special Vehicles Standard Delivery Monday to Friday
UK.Special
Hiab (includes time slot)
Flat bed (includes time slot)
UK.Van
Transit van (size restrictions)
£340.00
Order processed by 14:00 Day 1 Delivery day 3
£100.00
Order processed by 14:00 Day 1 Delivery Day 2
MISCELLANEOUS
Special Vehicles Weekends
UK.Special
Hiab (includes time slot)
£340.00
Order processed by 14:00 Day 1 Delivery Day 3 or 4 (as requested)
Flat bed (includes time slot)
UK.Van
Transit van (size restrictions)
£100.00
Order processed by 14:00 Day 1 Delivery Day 2
Public holidays - request for deliveries on public holidays are considered on an individual basis
114
Residential, Commercial and Industrial
• Amendment or cancellation
after order entry deadline maybe
subject to additional costs
• T ime specific is a requested
delivery time plus or minus
30 mins
• T wo man deliveries can be
requested for heavier items and
deliveries above ground level
• Delivery address, site contact
name and number are provided
and any delivery restrictions must
be communicated prior to order
entry deadline
• Driver is not permitted to make
part delivery against a delivery
note. Additional charges may
apply for refused deliveries
• 48 hours notice required for Hi-ab
requests
• 95% of mainland UK deliveries =
next day
• For Transportation Lead Times see
http://www.daikin.co.uk/businesspartners/index.jsp
Goods Returns Procedure
Daikin UK policy for acceptable returned goods
Daikin UK policy for acceptable returned goods is as follows:
Units & Accessories: 10 working days from date of invoice
Spare Parts: 1 month from date of invoice
Daikin may accept unwanted goods provided they are boxed
in the original packaging, in perfect condition and have
not been used – provided they are also within the time scales
of the Daikin returns policy. To arrange the process of returning
goods, please complete a Goods Returns Form available from
www.daikin.co.uk/business-partners/trade and send by fax
or email to the following:
What Happens Next
Once the Goods Return Form is received, an email will be
sent to the confirmation email address provided notifying you of
the goods for collection and a date for this to be carried out.
If you have any queries regarding this date please respond to the
email address provided as soon as possible.
Fax: 0845 641 9150 or email: [email protected]
Once inspected and confirmation is received that the goods
are in perfect condition, a credit will be raised against the
original invoice.
Spare Parts:
* Please note returns for chillers and made to order units will not be accepted *
Units & Accessories:
Fax: 0845 641 9299 or email: [email protected]
Conditions of Returned Goods
All returned items are subject to a minimum 20% restocking/
administration charge with the following collection charges
applied to the final credit:
Collected goods up to 15KG: £15
Goods Covered by Warranty
Once a unit has been installed and commissioned, any faults
or breakdowns that occur should be reported to our warranty
department on:
Telephone: 0845 641 9275 or email: [email protected]
Collected goods over 16KG: £90
All returned goods will be fully inspected by our technical
engineers. If returned goods are in a non-satisfactory condition
then Daikin reserves the right to decline the return or apply an
increase to the restocking charge.
Damaged Items
We cannot accept claims for damages unless the goods are
signed for as damaged on the delivery note and notification is
received within 3 working days. Any damage identified can be
refused at point of delivery.
MISCELLANEOUS
If you find that goods are damaged after they have been
unpacked, please take photographs of the damage and contact
the Returns Team immediately.
Price List 2014
115
The Field Quality Service department (FQS)
The Field Quality Service department (FQS) supply a range of services to support the installer.
Aftersales Technical Helpdesk
Spares
This invaluable service offers technical support and guidance
when you are experiencing on-site problems commissioning
or diagnosing faults. Final diagnosis is the responsibility of the
site engineer.
When a component fails, field expertise is pointless unless you
have quick access to spares. Daikin have over 12,000 parts based
in the UK, supported by our European parts centre with 600,000
parts. This helps us to achieve our target of providing 95% of
critical A parts within a 2 day delivery.
Your calls will be answered by Daikin trained engineers. To help
provide a quick and efficient response please make sure you
have the full model number of the unit. It is important to remind
you that using the D1/D1+ PIN number gives you priority access
to our engineers.
To contact the spares team directly
Tel 0845 641 9230
Fax 0845 641 9299
You can access this service Mon – Fri 8.30 -5.30pm
Email [email protected]
Tel 0845 641 9200
Fax 0845 641 9299
Email [email protected]
SMS Fault Code Service 07797 801908
If you need an explanation and remedy on a fault code and
haven’t got your service manual, just send the fault code to our
SMS message service and we will advise you by return.
Field Service
We can provide field engineers to assist you on-site for
commissioning or service intervention. All work is documented
in a report and sent for your records. Since we are working on
your site on your behalf it is essential that you are in attendance
at that time.
To book an engineer contact us on:
Tel 0845 641 9229
Email [email protected]
MISCELLANEOUS
Workshop
In our workshop on the outskirts of Bristol we modify standard
Daikin equipment to current specifications that meet our
client’s needs. The modifications include weatherised vams,
floor mounted fan coil conversions, strip and rebuild to name
a few. Think of the savings in time and money by having your
next VRV outdoor unit delivered to site in sections for placing
in position on the roof, saving at the cost of cranes and road
closure applications. Speak to your sales representative for more
information on what is available.
116
Residential, Commercial and Industrial
If you hold a direct account with Daikin UK, you can send
your spare parts order to us directly using our Spares
Parts Bank. This is available 24 hours a day 365 days a year,
and allows you to view and order your parts online at any
time of day. Plus, all orders processed through Spares Parts
Bank have no delivery charge, which is equivalent to almost
5% extra discount.
To register for Spares Parts Bank go to
www.daikin.co.uk/spares.
Daikin UK commercial warranty
If you have a component failure and it is within the warranty
period then we are here to help. After you have spoken to our
helpdesk to confirm diagnosis, you can simply contact the
warranty team.
Contact the warranty team on:
Tel 0845 641 9275
Fax 0845 641 9298
Email [email protected]
• T he engineer has attended a Daikin Training course relevant to
the equipment being installed
• Repeat warranty replacements will be subject to investigation
by the manufacturer
• Daikin products that are relocated from their original
installation are excluded
• Normal wear and tear is excluded
Procedure:
• Daikin UK receives a claim for warranty replacement: dispatch
parts, together with warranty forms, returns documentation
and invoice
You can also process your claim online at the warranty section of
the Extranet. Here you will find process claim forms and our full
warranty terms.
• T he warranty forms must be returned to Daikin UK within 14
days. Faulty parts must be available for collection by Daikin UK
for up to 60 days
The following sets out the Daikin Airconditioning UK Ltd
(Daikin UK) current warranty policies:
• Daikin UK receives correctly completed claim form (and faulty
parts if required) and then issues the appropriate credit or
technical rejection
• Standard warranty is 3 years parts and labour
• Daikin offers 5 years plus double labour allowance to
D1 /D1+ approved installers
Within the warranty period, products are guaranteed against
manufacturing faults in material and workmanship. Replacement
parts will be supplied free of charge, together with a fixed labour
allowance, as set out in the table below, provided the correct
procedures are complied with.
The warranty policies are subject to the
following conditions:
• T he Daikin equipment is installed commissioned and
maintained throughout by a suitably qualified and
certificated refrigeration engineer, and in accordance with
the manufacturer’s recommendations
General Components
• Any claim submitted thirty (30) days after invoice date WILL
NOT be considered for credit
• Any claim not submitted in accordance with our procedures
WILL NOT be considered for credit
• Payment for warranty claims will only be made by credit note
• Any additional cost associated with the replacement of the
actual warranty part (i.e. any cost not itemised in the list of
allowances, travel, refrigerant, waiting time, access equipment)
will be disallowed by Daikin UK
• T hroughout the warranty period maintenance records must be
kept and available for inspection upon request
3 year allowances
5 year allowances
A1
Replacement of components within refrigeration circuit
£52.00
£104.00
A2
Repair of internal pipework (does not include installation pipework)
£28.00
£56.00
A3
Replacement of air supply fan motor (evaporator and condenser fan motor)
£20.00
£40.00
A4
Replacement of fan blade
£16.00
£32.00
A5
Replacement of electrical/electronic components
£16.00
£32.00
A6
Replacement of condensate drain lift up mechanism
£12.00
£24.00
A7
Replacement of auto swing louvre motor
£12.00
£24.00
A8*
Dead on arrival of unit (packaged type)
£40.00
£80.00
A9*
Dead on arrival of unit (split type)
£72.00
£144.00
3 year allowances
5 year allowances
Compressors Size
B1
< 2.5 HP
£84.00
£168.00
B2
2.5 HP < 5 HP
£100.00
£200.00
B3
5HP < 10 HP
£150.00
£300.00
B4
10 HP < 20 HP
£200.00
£400.00
B5
25 HP < 50 HP
£260.00
£520.00
B6
50 HP < 100 HP
£360.00
£720.00
B7
100 HP >
£480.00
£960.00
MISCELLANEOUS
* Note: A8 & A9 will be single payment if unit is returned without any repairs
Daikin UK reserve the right to update this warranty (and its terms and conditions), from time to time, without notice.
Price List 2014
117
Daikin UK’s customised product training
Designed to raise standards, set industry benchmarks and help you develop both product and service
expertise. You will receive the highest quality training and hands-on instruction at our industry leading
technology centres.
Latest range of products
Courses are available to attend at Bristol, Woking, Birmingham,
Manchester and Glasgow. The Daikin UK regional training centres
are fully equipped with the latest range of products, installed and
fully operational for maximum hands-on experience.
All training is given by highly skilled engineers who will be
able to provide you with extensive in depth knowledge of our
equipment. If you have any specific training requests outside of
the scheduled programme, please contact us.
A general overview of the style of course
content offered:
1. Product selection and application techniques
2. Installation and commissioning requirements
3.Daikin centralised control systems application
and commissioning
4.Advanced service and fault finding for field engineers
Why invest in training on the latest systems:
Daikin UK training centres
>The rapidly growing market in heat pumps and heat
recovery systems offers major new business opportunities
1 Bristol
Daikin Airconditioning UK Limited
Maple House, Brotherswood Court,
Great Park Road, Almondsbury,
Bristol BS32 4QW
>New technologies require wider knowledge of heating,
refrigeration and safe handling techniques
>Tighter regulations demand certified skills and renewal
of existing certifications
>Specialist training programmes provide invaluable
hands-on experience in the very latest technologies
2 Woking
Daikin Airconditioning UK Limited
1 River Court, Albert Drive, Woking,
Surrey GU21 5RP
3 Birmingham
Daikin Airconditioning UK Limited
Unit 8, Holly Park, Spitfire Road,
Birmingham, West Midlands B24 9PB
4 Manchester
Daikin Airconditioning UK Limited
17b Cobra Court, Blackmore Road,
Manchester M32 0QY
MISCELLANEOUS
5 Glasgow
Daikin Airconditioning UK Limited
Unit 2, Glasgow Airport Business Park,
Marchburn Drive, Paisley PA3 2SJ
To find out when courses are scheduled at regional Daikin UK training centres,
check availability and book a place, please go to the Daikin UK booking web site
system at www.daikintraining.co.uk
118
Residential, Commercial and Industrial
Courses now available around the UK
With Daikin UK’s support, specialist further education colleges around the UK are offering
high-class training with state-of-the-art equipment, helping raise industry standards, for the highly
skilled engineers who are in increasing demand.
Course categories and available Training Centres
Daikin UK
Training
Centres
City of
Bath
College
College
of North
West
London
Dudley
College
Energy
Training Hub
West
Suffolk
College
PGL
College
Daikin air conditioning products
4
8
8
8
4
8
Daikin controls
4
8
8
8
8
8
Daikin chiller products
4
8
8
8
8
8
Daikin refrigeration products
4
8
8
8
8
8
Industry related refrigeration practical skills
8
4
4
4
8
8
Daikin heating products (see separate brochure)
4
8
8
4
4
4
Industry accredited heating courses (see separate brochure)
8
8
4
4
8
4
Growth together
College collaborations
Daikin UK is committed to ensuring that the next generation
of heating, air conditioning and ventilation engineers have the
specialist skills and practical experience required to install and
maintain the innovative new technologies that can improve
the performance of HVAC-R systems while reducing their
environmental impact.
So far, this on going initiative has created the following
collaborations with Daikin UK:
2 College of North West London
3 Dudley College
4 West Suffolk College
5 PGL Training
MISCELLANEOUS
In turn, this will help employers who invest in apprenticeships
and ongoing training of their engineers to capitalise on the
growing business opportunities for companies with proven
expertise in delivering highly energy-efficient climate
control systems.
1 City of Bath College
Each college offers carefully prepared training courses.
For more information, please contact your nearest college directly.
Price List 2014
119
Conditions of Sale
4
1(a)In these Conditions:-
4(a) The price of goods shall be the Seller’s quoted price. Where the price quoted is
specified as fixed for a certain period of time the price will be as fixed provided delivery
takes place within the period, unless the Buyer has requested a change in delivery
date, quantity or specification for the Goods or delay is caused by any instruction of
the Buyer or failure of the Buyer to give the Seller adequate information or instructions
in which case the Seller may give notice to the Buyer in similar manner to the notice
referred to in clause 4(b).
‘Buyer’ means the corporation, firm, company, institution, person or persons to whom
a quotation is made or to whom goods are sold by the company;
‘Goods’ means the goods which the Seller is to supply in accordance with these
Conditions;
‘Seller’ means Climate Controls and Spares UK Ltd (Company Registration No: 6847224)
‘Conditions’ means the standard terms and conditions of sale set out in this document
and (unless the context otherwise requires) includes any special terms and conditions
agreed in writing between the Buyer and the Seller;
‘Contract’ means the contract for the purchase and sale of the Goods;
‘Writing’ includes letter, email and facsimile transmission;
1(b) Any reference in these Conditions to any provision of a statute shall be construed as
a reference to that provision as amended, re-enacted or extended at the relevant time.
1(c) The headings in these Conditions are for convenience only and shall not affect
their interpretation.
2
Basis of the Sale
2(a) The Seller shall sell and the Buyer shall purchase the Goods in accordance with any
written quotation of the Seller which is accepted by the Buyer, or any written order of
the Buyer which is accepted by the Seller, subject in either case to these Conditions,
which shall govern the Contract to the exclusion of any other terms and conditions
subject to which any such quotation is accepted or purported to be accepted, or any
such order is made or purported to be made by the Buyer.
2(b) No variation to these Conditions shall be binding unless agreed in Writing
between the authorised representatives of the Buyer and the Seller.
2(c)The Seller’s employees or agents are not authorised to make any representation
concerning the Goods unless confirmed by the Seller in Writing. In entering into the
Contract the Buyer acknowledges that it does not rely on, and waives any claim for
breach of any such representations which are not so confirmed.
2(d)Any advice or recommendation given by the Seller or its employees or agents to
the Buyer or its employees or agents as to the storage, application or use of the Goods
which is not confirmed in writing by the Seller is followed or acted upon entirely at the
Buyer’s own risk, and accordingly the Seller shall not be liable for any such advice or
recommendation which is not so confirmed.
2(e)Any typographical, clerical or other error or omission in any sales literature, quotation,
price list, acceptance of offer, invoice or other document or information issued by the
Seller shall be subject to correction without any liability on the part of the Seller.
3
Orders and specification
3(a)No order submitted by the Buyer shall be deemed to be accepted by the Seller
unless and until confirmed in Writing by the Seller.
3(b)The Buyer shall be responsible to the Seller for ensuring the accuracy of the terms
of any order (including any applicable specification) submitted by the Buyer, and for
giving the Seller any necessary information relating to the Goods within a reasonable
time to enable the Seller to perform the Contract in accordance with its terms.
3(c) The quantity, quality and description of and any specification for the Goods shall
be those set out in the Seller’s quotation or the Buyer’s order (if accepted by the Seller).
3(d)If the Goods are to be manufactured or any process is to be applied to the Goods
by the Seller in accordance with the specification submitted by the Buyer, the Buyer
shall indemnify the Seller against all loss, damages, costs and expenses awarded
against or incurred by the Seller in connection with or paid or agreed to be paid by the
Seller in settlement of any claim for infringement of any patent, copyright, design, trade
mark or other industrial or intellectual property rights of any other person which results
from the Seller’s use of the Buyer’s specification. The Buyer will also fully indemnify the
Seller in respect of all other loss, damages, costs and expenses incurred by the Seller
and arising out of the supply of the Goods.
MISCELLANEOUS
Price of goods
1Interpretation
3(e) The Seller reserves the right to make any changes in the specification of the
Goods which are required to conform with any applicable safety or other statutory
requirement or, where the Goods are to be supplied to the Seller’s specification, which
do not materially affect their quality or performance.
3(f) No order which has been accepted by the Seller may be cancelled by the Buyer
except with the agreement of the Seller and on terms that the Buyer shall indemnify
the Seller with a percentage of the original quoted cost of the goods and with any
other charges and expenses incurred by the Seller as a result of cancellation.
120
Residential, Commercial and Industrial
4(b) Where the price quoted is not specified as fixed for a certain period of time the
Seller may, by giving notice to the Buyer at anytime before delivery increase the price
of the Goods to reflect any increase in the cost to the Seller which is due to any factor
beyond the control of the Seller or due to any increase caused by any of the events
specified in clause 4(a).
4(c) All prices are given by the Seller on an ex-works basis, and where the Seller agrees
to deliver the Goods otherwise than at the Seller’s premises, the Buyer shall be liable to
pay the Seller’s charges for transport, packaging and insurance. All packaging will be
subject to an additional charge.
4(d) The price is exclusive of any applicable value added tax, which the Buyer shall
be additionally liable to pay to the Seller and shall be paid without any deductions or
withholdings and without any right of set off and counterclaim.
5
Terms of payment
5(a) Subject to any special terms agreed in Writing between the Buyer and the Seller,
the Seller shall be entitled to invoice the Buyer for the price of the Goods on or at
anytime after delivery of the Goods, unless the Goods are to be collected by the Buyer
or the Buyer wrongfully fails to take delivery of the Goods in which event the Seller shall
be entitled to invoice the Buyer for the price at any time after the Seller has notified
the Buyer that the Goods are ready for collection or (as the case may be) the Seller has
tendered delivery of the Goods.
5(b) Provided the Seller shall have offered to and agreed credit facilities with the Buyer,
the Buyer shall pay the price of the Goods in accordance with the Seller’s terms of
payment that are specified on the Seller’s invoice, notwithstanding that delivery may
not have taken place and the property in the Goods has not passed to the Buyer. If
credit facilities have not been so agreed payment shall be due upon availability or
(where the Goods are to be collected by the Buyer) upon the Seller notifying the Buyer
that the goods are ready for collection or where the Seller wrongfully fails to take
delivery of the Goods upon the Seller tendering delivery of the Goods. The time of
payment of the price shall be of the essence of the Contract. Receipts for payment will
be issued only upon request.
5(c) The Seller reserves the right to terminate any credit facilities upon notice to the
Buyer, such notice having immediate effect where upon any monies owed to the Seller
by the Buyer will become due for payment immediately.
5(d) If the Buyer fails to make any payment on the due date then, without prejudice to
any other right or remedy available to the Seller, the Seller shall be entitled to:
5(d)1 cancel the contract or suspend any further deliveries to the Buyer
5(d)2 appropriate any payment made by the Buyer to such of the Goods (or the goods
supplied under any other contract between the Buyer and the Seller) as the Seller may
think fit (notwithstanding any purported appropriation by the Buyer) and charge the
Buyer interest (both before and after any judgment) on the amount unpaid, at the rate
of 8 per cent per annum above the Bank of England base rate from time to time, until
payment in full is made.
6Delivery
6(a) Delivery of the Goods shall be made by the Buyer collecting the Goods at the
Seller’s premises at anytime after the Seller has notified the Buyer that the Goods are
ready for collection or, if some other place for delivery is agreed by the Seller, by the
Seller delivering the Goods to that place.
6(b) Any dates quoted for delivery of the Goods are approximate only and the Seller
shall not be liable for any delay in delivery of the Goods howsoever caused. Time for
delivery shall not be of the essence unless previously agreed by the Seller in Writing.
The Goods may be delivered by the Seller in advance of the quoted delivery date.
6(c) The Seller will not be liable for non-delivery or damage or shortages in the Goods
unless:
6(c)1 the Buyer notifies the Seller within three days of receipt of the Goods or in the
event of non-delivery within three days of receipt of the invoice and
6(c)2 a claim is made within 20 working days of such receipt and the Seller shall be
permitted to inspect the Goods on the Buyer’s premises.
6(e) If the Seller fails to deliver the Goods for any reason other than any cause beyond
the Seller’s reasonable control or the Buyer’s fault, and the Seller is accordingly liable
to the Buyer, the Seller’s liability shall be limited to the excess (if any) of the cost to the
Buyer (in the cheapest available market) of similar goods to replace those not delivered
over the price of the Goods.
6(f) If the Buyer fails to take delivery of the Goods or fails to give the Seller adequate
delivery instructions at the time stated for delivery (otherwise than by reason of any
cause beyond the Buyer’s reasonable control or by reason of the Seller’s fault) then,
without prejudice to any other right or remedy available to the Seller, the Seller may:
6(f1) store the Goods until actual delivery and charge the Buyer for the reasonable
costs (including the insurance) of storage, or
6(f2) after a reasonable period of time, sell the Goods at the best price readily
obtainable and (after deducting all reasonable storage and selling expenses) account
to the Buyer for the excess over the price under the Contract or charge the Buyer for
any shortfall below the price under the Contract.
7Returns
7(a) Goods to be returned from the Buyer to the Seller for any reason, shall be returned
only upon authorisation from the Seller.
7(b) Goods returned by the Buyer to the Seller without authorisation from the Seller,
shall not be accepted onto the Seller’s premises. The Seller shall not be responsible for
any costs incurred by the Buyer in this event.
7(c) Goods will only be considered (by the Seller) to be accepted for return providing
the following conditions are met:
7(c1) the Goods have been purchased within 28 working days of the Buyer’s request
to return the Goods.
7(c2) the Goods have (at the Seller’s opinion) in no way been used, misused or modified
and are in their original packaging and are in an immediately re-saleable condition.
7(d) Goods that are specially manufactured or modified from their original condition in
accordance with the Buyer’s order cannot be returned.
7(e) Goods that are classed (at the Seller’s opinion) as non-catalogue or specially
ordered items cannot be returned.
7(F) Printed Circuit Board’s (PCB’s) and other items containing electronic components
such as Digital Time Controls, Burner Sequence Controls etc. cannot be returned.
7(g) The Seller withholds the right to offer replacement, refund or repair of the Goods
subject to the return of the Goods (at the Seller’s Discretion) to the Seller’s supplier
or the manufacturer of the Goods for inspection and testing where necessary to
deem the Goods are defective, or have become defective not as a result of any of the
conditions as stated in clause 9(b2).
7(h) Any Goods accepted by the Seller will be subject to a handling charge.
8
Risk and property
8(a) Risk of damage to or loss of the Goods shall pass to the Buyer.
8(a1) in the case of Goods to be delivered at the Seller’s premises, at the time when the
Seller notifies the Buyer that the Goods are available for collection; or
8(a2) in the case of Goods to be delivered otherwise than at the Seller’s premises, at
the time of delivery or if the Buyer wrongfully fails to take delivery of the Goods, the
time when the Seller has tendered delivery of the Goods.
8(b) Notwithstanding delivery and the passing of risk in the Goods, or any other
provision of these Conditions, the title in the Goods shall not pass to the Buyer until the
Seller has received in cash or cleared funds payment in full of the price of the Goods
and all other Goods agreed to be sold by the Seller to the Buyer for which payment is
then due.
8(c) Until such time as the title in the Goods passes to the Buyer, the Buyer shall hold
the Goods as the Seller’s fiduciary agent and bailee, and shall keep the Goods separate
from those of the Buyer and third parties and properly stored, protected and insured
and identified as the Seller’s property. Until that time the Buyer shall be entitled to resell
or use the Goods in the ordinary course of its business, but shall account to the Seller
for the proceeds of sale or otherwise of the Goods, whether tangible or intangible.
Including insurance proceeds, and shall keep all such proceeds separate from any
monies or property of the Buyer and third parties and, in the case of tangible proceeds,
property stored, protected and insured.
8(d) deliver up the Goods to the Seller and, if the Buyer fails to do so forthwith, to enter
upon any premises of the Buyer or any third party where the Goods are stored and
repossess the Goods.
8(e) The Buyer shall not be entitled to pledge or in any way charge by way of security
for any indebtedness any of the Goods which remain the property of the Seller, but if
the Buyer does so all monies owing by the Buyer to the Seller shall (without prejudice
to any other right or remedy of the Seller) forthwith become due and payable.
9
Warranties and liability
9(a) The Seller warrants that the Goods will be free from defects in materials and
workmanship for a period of twelve months from delivery and will correspond with
their specification at the time of delivery. If within twelve months from the date of
delivery the Buyer shall notify the Seller in writing that a defect exists in the Goods
and shall return the defective part at their own expense to the Seller and if the Seller
is satisfied that such defect arose solely from faulty materials or workmanship of the
Seller (or its suppliers in the case of Goods not manufactured by the Seller) the Seller
will at its option replace, refund or repair the defective part. The Buyer will not be
responsible for the cost of replaced items but will be responsible for the cost of labour
where an item is repaired.
9(b) The above warranty is given by the Seller subject to the following conditions:
9(b1) the Seller shall be under no liability in respect of any defect in the Goods arising
from any drawing, design or specification supplied by the Buyer.
9(b2) the Seller shall be under no liability in respect of any defect arising from fair wear
and tear, wilful damage, negligence, abnormal working conditions (including but not
limited to hiring out the Goods to third parties), failure to follow the Seller’s instructions
(whether oral or in writing), incorrect application, misuse, alteration or repair of the
Goods without the Seller’s approval. (In certain instances it will be necessary for the
Seller to return the Goods to the Seller’s supplier to verify that the Goods have not
become defective due to any of the aforementioned reasons).
9(b3) the Seller shall be under no liability under the above warranty (or any warranty,
condition or guarantee) if the total price for the Goods has not been paid by the due
date for payment.
9(c) Subject as expressly provided in these Conditions, and except where the Goods
are sold to a person dealing as a consumer (within the meaning of the Unfair Contract
Terms Act 1977), all warranties, conditions or other terms implied by statute or common
law are excluded to the fullest extent permitted by law.
9(d) Where the Goods are sold under a consumer transaction (as defined by the
Consumer Transactions (Restriction on Statement Order 1976)) the statutory rights of
the Buyer are not affected by these Conditions.
9(e) Except in respect of death or personal injury caused by the Seller’s negligence, the
Seller shall not be liable to the Buyer by reason of any representation, or any implied
warranty, condition or other term, or any duty at common law, or under the express
terms of the Contract, for any consequential loss or damage (whether for loss or
profit or otherwise), costs, expenses or other claims for consequential compensation
whatsoever (and whether caused by the negligence of the Seller, it’s employees or
agents or otherwise) which arise out of or in connection with the supply of the
Goods or their use or resale by the Buyer, except as expressly provided in these
Conditions.
9(f) The Seller shall not be liable to the Buyer or be deemed to be in breach of the
Contract by reason of any delay in performing or any failure to perform, any of the
Seller’s obligations in relation to the Goods, if the delay or failure was due to any cause
beyond the Seller’s reasonable control. Without prejudice to the generality of the
foregoing, the following shall be regarded as causes beyond the Seller’s reasonable
control:
9(f1) Act of God, explosion, flood, tempest, fire or accident;
9(f2) war or threat of war, sabotage, insurrection, civil disturbance or requisition;
9(f3) acts, restrictions, regulations, bye-laws, prohibitions or measures of any kind on
the part of any governmental, parliamentary or local authority;
9(f4) import or export regulations or embargoes;
9(f5) strikes, lock-outs or other industrial actions or trade disputes (whether involving
employees of the Seller or a third party);
9(f6) difficulties in obtaining raw materials, labour, fuel, parts or machinery;
9(f7) power failure or breakdown in machinery;
10 Insolvency of Buyer
10(a) This clause applies if:
10(a1) the Buyer makes any voluntary arrangement with its creditors or becomes
subject to an administration order or (being an individual or firm) becomes bankrupt
or (being a company) goes into liquidations (otherwise than for the purpose of
amalgamation or reconstruction), or
10(a2) an encumbrancer takes possession, or a receiver is appointed, of any of the
property or assets of the Buyer, or
Price List 2014
121
MISCELLANEOUS
6(d) Where the Goods are to be delivered in instalments, each delivery shall constitute
a separate contract and failure by the Seller to deliver any one or more of the
instalments in accordance with these conditions or any claim by the Buyer in respect
of any one or more instalment shall not entitle the Buyer to treat the Contract as a
whole as repudiated.
10(a3) the Buyer ceases, or threatens to cease, to carry on business; or
11General
10(a4) the Seller reasonably apprehends that any of the events mentioned above is
about to occur in relation to the Buyer and notifies the Buyer accordingly.
11(a) Any notice required or permitted to be given by either party to the other under
these Conditions shall be in Writing addressed to that other party at its registered office
or principal place of business
10(b) If this clause applies then, without prejudice to any other right or remedy
available to the Seller, the Seller shall be entitled to cancel the Contract or suspend
any further deliveries under the Contract without any liability to the Buyer, and if the
Goods have been delivered but not paid for the price shall become immediately due
and payable notwitstanding any previous agreement or arrangement to the contrary.
In the event of non-payment to the Seller by the Buyer the Seller shall be entitled to
recover the Goods under the provisions of the retention of title clause (Section 8).
or such other address as may at the relevant time have been notified pursuant to this
provision to the party giving the notice.
11(b) No waiver by the Seller of any breach of the Contract by the Buyer shall be
considered as a waiver of any subsequent breach of the same or any other provision.
11(c) If any provision of these Conditions is held by any competent authority to be
invalid or unenforceable in whole or in part the validity of the other provisions of these
Conditions and the remainder of the provision in question shall not be affected thereby.
MISCELLANEOUS
11(d) The Contract shall be governed by the laws of England & Wales and the parties
submit to the jurisdiction of the English courts.
122
Residential, Commercial and Industrial
your comfort. our world.
www.climatecontrolsandspares.co.uk
For further information visit our website at www.climatecontrolsandspares.co.uk or call into your local branch.
Whilst every care has been taken to ensure that the information included in this document was accurate at the time of printing, we reserve the right to change specifications at any time.
The photographs reproduced in this publication are within the constraints of the printing process and are NOT to be used for matching purposes. We must also point out that goods will
be invoiced at prices ruling at the date of dispatch unless otherwise agreed. E&OE.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement