Euramco Safety UB30 Owner's Manual

Add to my manuals
9 Pages

advertisement

Euramco Safety UB30 Owner's Manual | Manualzz

   

UB20/

UB30

Owner’s Manual

Euramco  Safety,  Inc.  

2746  Via  Orange  Way  

Spring  Valley,  CA  91978  USA  

USA  1.800.4.RAMFAN    

Tel  +1.619.670.9590  

Fax  +1.619.670.7345  

  [email protected]   www.EuramcoSafety.com  

 

 

 

 

 

 

SM-­‐UB20  Rev  A  

 

 

Preface  

 

Thank  you  for  purchasing  the  RAMFAN®  UB20  or  UB30  utility  blower  manufactured  by  Euramco  Safety,  Inc.    

For  more  than  30  years  Euramco  Safety  has  been  on  the  cutting  edge  of  industrial,  fire,  and  marine  ventilation   products.    Each  and  every  one  of  our  blower/exhausters,  smoke  ejectors,  PPV  &  LSV  fans  and  accessories  represent   the  finest  technologies  available.    Every  product  is  constructed  to  demanding  and  exact  specifications  for  quality,   performance,  and  reliability.  

When  human  life  depends  on  having  a  fan  that  can  deliver  clean,  safe  air,  you  have  only  one  choice  you  can  trust:  

RAMFAN.  

Explore  our  website  and  online  catalog  at   www.EuramcoSafety.com   and  discover  how  RAMFAN  can  make  a   difference  in  the  field!  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This  manual  covers  operation  and  maintenance  procedures  for  the  RAMFAN  UB20  and  UB30  utility  blower/exhausters.  

All  product  information  in  the  publication  is  based  on  the  most  current  information  available  at  the  time  of  

 

printing.  Euramco  Safety,  Inc.  reserves  the  right  to  make  changes  at  any  time  without  notice.    

 

                 

 

READ  MANUAL  BEFORE  STARTING  FAN  FOR  FIRST  TIME!  

 

UB20/UB30  Owner’s  Manual  |  Euramco  Safety,  Inc.  |  SM-­‐UB20  Rev  A   1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table  of  Contents  

 

1  |  Specifications/Warnings  ................................................................................................................................  3  

2  |  Features  &  Benefits    ...................................................................................................................................  3,  4  

3  |  Safety  Precautions  .....................................................................................................................................  4,  5  

4  |  Operation  .........................................................................................................................................................  5  

5  |  Maintenance  ................................................................................................................................................  5,  6  

6  |  Troubleshooting  .............................................................................................................................................  6  

7  |  Spare  Parts  ..................................................................................................................................................  7,  8  

UB20/UB30  Owner’s  Manual  |  Euramco  Safety,  Inc.  |  SM-­‐UB20  Rev  A   2

 

 

 

1  |Specifications/  Warnings  

MODEL   UB20    

Part  Number   ED7002  

Airflow  

Power    

980  cfm  

115V,  50/60Hz  

Power  input  max.  (Start  /  Run)   9.5A  /  2.5A    

Motor  output  max.     1/3  Hp  

Protection  class  

Height  x  Width  x  Length  

Weight    

Sound  level  @  3’  /  1  m  

IP55  

14  x  12  x  13  in  

17  lbs  

74    dB(A)  

ED8002  

1392  m³/h  

230V,  50/60Hz  

4.8A  /  1.3A    

0.25  kW  

IP55  

36  x  31  x  33  cm  

8    kg  

74    dB(A)  

UB30  

EJ4002  

2420  cfm  

115V,  50/60Hz  

33A  /  8A  

1  Hp  

IP55  

20  x  15.5  x  12  in  

37  lbs  

90  db(A)    

EJ8002  

3429    m³/h  

230V,  50/60Hz  

17A  /  5A  

0.8kW  

IP55  

51  x  39  x  31  cm  

17lbs  

90  db(A)  

 

*  

Specifications  are  subject  to  change  without  notice.  Some  values  are  approximate.  

 

 

             

             

CAUTION!    

Thermally  Protected  for  Indoor/Outdoor  Use  

To  protect  the  user,  this  unit  is  equipped  with  thermal  overload  protection  and  automatic  reset.  Motor  will  restart   without  warning  after  protector  trips.  If  motor  thermal  protection  trips,  disconnect  unit  and  determine  cause.  

 

 

 

Do  NOT  change  make  or  model  of  fan  or  motor.      

2  |  Features  &  Benefits    

               

RAMFAN®  combines  high  performance  turbofan  design  with  high  strength  polymers  to  create  a  line  of  rugged,   portable  turbo  blowers.  The  UB-­Line  is  ideal  for  general  use,  confined  space  ventilation  and  delivers  the  highest   airflow  in  its  class.  The  double-­wall,  polyethylene  casing  is  light-­weight,  corrosion  and  chemical  resistant  and   handles  the  bumps  and  falls  of  any  job  site.    

 

The  8"/20  cm  UB20  turbo  blower  is  at  the  heart  of  the  RAMFAN  industrial  ventilation  systems  that  provide  you  with   the  complete  solution  for  common  confined  space  ventilation  applications.  The  multi-­purpose  blower  and  exhauster  

  delivers  powerful  airflow  in  a  compact  and  lightweight  package.  

•   Compact  &  Lightweight    

•   Integrated  Duct  Adapter  

•   Cord  Strap  

•   15'/4.6  m  Extended  Reach  Power  Cable  

•   Ultra  Quiet  

•   Easily  attaches  Quick-­Couple™  Duct  Canister  for  Exhaust/Suction  

 

The  12"/30  cm  UB30  takes  design  cues  from  the  UB20  in  a  larger  form.  The  larger  blower/exhauster  produces  a   higher  airflow  for  use  in  larger  confined  spaces.  The  larger  the  area  you  are  trying  to  ventilate  the  more  airflow  you’ll  

UB20/UB30  Owner’s  Manual  |  Euramco  Safety,  Inc.  |  SM-­‐UB20  Rev  A   3

  need.  The  RAMFAN®  UB30  has  unmatched  performance  for  a  fan  its  size.  It  is  built  with  a  durable  housing  to   withstand  industrial  workspace  environments.    

•   2  Integrated  Duct  Adapters  

•   Dual  Voltage/  Dual  Frequency  

•   Stackable  design  feature  

•   Cord  Strap  

•   15'/4.6  m  Extended  Reach  Power  Cable  

 

 

 

3  |  Safety  Precautions    

 

           

 

Before  Operation  

   

Before  starting  for  the  first  time:  DO  NOT  START  fan  if  there  are  any  signs  of  shipping  damage,  

  particularly  to  blade,  guards,  or  housing.  If  ANY  damage  is  suspected,  STOP  and  call  your  dealer   immediately.  

Keep  children  away:  Do  not  allow  children  to  play  with  or  around  the  unit,  which  could  result  in  injury.  Be   sure  the  unit  is  inaccessible  to  children  when  not  attended.  

 

Keep  unit  grounded:  Always  operate  the  unit  with  a  grounding  plug  and  a  grounded  electrical  outlet.  A   grounding  plug  is  an  essential  safety  feature  that  helps  reduce  the  risk  of  shock  or  fire.  Always  ensure  the   switch  is  in  the  OFF  position  prior  to  connecting  to  power.  

 

Protect  power  cord  from  damage:  Use  cords  of  suitable  size  for  amperage  load.  Never  operate  a  unit  with   a  damaged  power  cord,  as  this  may  lead  to  electrical  or  fire  hazards.  

 

 

Extension  Cords:  Extension  cords  must  be  grounded  and  able  to  deliver  the  appropriate  voltage  to  the  unit.  

Do  not  use  speed  control  device:  To  reduce  the  risk  of  fire  or  electric  shock,  do  not  use  fans  with  a  solid-­ state  speed  control  device.  

 

Handle  with  care:  Do  not  drop  or  throw  the  unit.  Rough  treatment  can  damage  the  components  or  wiring  and  

  create  a  hazardous  condition.  

Run  on  stable  surface:  Start  only  if  blower  is  sitting  in  a  stable  and  upright  position.  While  on  level  surface   and  running  at  full  speed,  the  blower  should  not  move  around.  If  unit  is  moving,  check  rubber  feet  for  damage   and  replace  if  necessary.  

 

 

Secure  during  transport:  When  transporting  in  a  vehicle,  secure  the  unit  to  prevent  sliding  and  possible   injury  to  vehicle  occupants.  

 

 

 

During  Operation  

Airflow  Direction:  When  using  the  blower,  note  the  directional  airflow  indicator  on  the  external  housing.  

 

UB20/UB30  Owner’s  Manual  |  Euramco  Safety,  Inc.  |  SM-­‐UB20  Rev  A   4

Keep  out  of  water:  Never  operate  the  unit  in  pooled  or  standing  water,  as  this  may  create  a  risk  of  injury   from  electrical  shock.  Do  not  store  outdoors.  If  electrical  wiring  or  components  become  wet,  thoroughly  dry  

  them  before  using  the  unit.    

Safety:  Proper  ear  and  eye  protection  must  be  worn  while  blower  is  running.  Keep  fingers  and  hands  clear  of  

  blade.  Do  not  move  blower  while  it  is  running.  

Keep  air  intakes  clear:  Do  not  clog  or  block  air  intakes,  this  may  occur  if  operated  to  close  to  loose   lightweight  objects  such  as  clothing  or  leaves.  This  can  cause  the  unit  to  overheat  and  result  in  a  fire  or  

  electrical  hazard.  

Keep  away  dust  and  dirt:  Do  not  allow  dust,  dirt,  or  other  particles  to  be  drawn  into  the  air  intakes.  Dirt  in  the   motor  can  cause  it  to  overheat,  resulting  in  a  fire  or  electrical  hazard.  If  the  motor  gets  dirty,  clean  it  using  an  

  air  hose.  

Allow  repair  only  by  qualified  person:  Immediately  stop  the  unit  upon  hearing  excessive  mechanical  noise   or  vibration.  Do  not  attempt  to  disassemble  or  repair  the  unit  if  you  are  not  qualified  to  do  so.  You  can  perform   regular  maintenance  or  troubleshooting,  however  complex  problems  need  to  be  repaired  by  an  authorized   service  technician.    

 

For  information  about  authorized  repair,  call  Euramco  Safety  Customer  Service  at  +1  (619)  670-­9590.  

 

 

 

 

4  |  Operation    

 

1.   Read  the  Owner's  Manual  completely  before  starting  fan.  

 

2.   Wear  both  eye  and  ear  protection.    

 

3.   Position  the  fan  on  a  level  surface.  

 

4.   Plug  in  to  a  standard  outlet  with  the  correct  voltage  and  amperage  for  the  unit.  Set  the  switch  to  ON.  Check   for  proper  operation  before  leaving  the  unit  unattended.  Do  not  move  or  carry  the  blower  while  it  is  running  

 

 

5  |  Maintenance            

 

LOCK-­OUT  /  TAG-­OUT:  When  performing  any  maintenance,  always  follow  all  additional  safety  precautions   that  your  company  may  have  for  lock-­out  /  tag-­out  procedures.  

 

POWER  OFF:  Always  turn  the  power  OFF  and  unplug  the  unit  before  performing  maintenance  procedures.  All   the  service  procedures  below  are  to  be  executed  with  the  unit  unplugged.  Perform  before  each  use  or  as   needed.  

 

 

DO  NOT  DISSASSEMBLE  blower  for  maintenance  reasons.  

INSPECT  ELECTRICAL  SYSTEM:  Inspect  the  electrical  cord  for  damage  at  regular  intervals.  Periodically,   inspect  internal  wiring  for  bare  wires,  insecure  fasteners,  and  discoloration.  Remove  and  repair  any  damaged  

  wiring  as  needed.  Failure  to  do  so  may  lead  to  electrical  shock  or  a  fire  hazard.    

UB20/UB30  Owner’s  Manual  |  Euramco  Safety,  Inc.  |  SM-­‐UB20  Rev  A   5

 

 

 

 

 

CLEAN  AIR  INTAKES:  Clean  off  any  accumulated  lint  or  other  materials  from  the  finger  guards.  A  build  up  will   reduce  the  airflow  and  may  cause  the  motor  to  overheat  and  become  a  fire  hazard.  NEVER  operate  fan  with  

  damaged  or  missing  finger  guards.              

CLEAN  EXTERIOR:  Clean  fan  periodically  to  remove  accumulated  dust  or  particles  using  a  commercially   available  biodegradable  cleaning  solution.  DO  NOT  use  solvents  containing  chlorinated  hydrocarbons  (i.e.  

MEK,  Acetone)  

 

EXTERIOR  INSPECTION:  Evaluate  exterior  components  and  make  sure  they  are  properly  installed.  Inspect   the  fan  for  loose  fasteners  at  least  once  every  6  months  depending  on  frequency  of  use.  Tighten  any  loose   fasteners  immediately.  DO  NOT  overtighten  fasteners.  

 

Listen  to  the  unit  for  abnormal  sounds.  Check  rubber  feet  for  excessive  wear  or  breakage.  Contact  Euramco  

 

Safety  for  replacement  parts  and  installation  instructions.  

DO  NOT  WET  MOTOR  OR  WIRING:  To  prevent  damage  to  electrical  components,  do  not  use  a  duct  or   pressure  washer  to  clean  a  blower.  If  electrical  components  do  become  wet,  dry  them  immediately.    

 

 

   

 

6  |  Troubleshooting        

 

WARNING:  Execute  all  the  service  procedures  below  with  the  blower  OFF  and  power  cord  unplugged.  

"FS"  or  Field  Solutions  can  be  handled  by  the  technician  in  the  field  |   "AST"  or  Authorized  RAMFAN  Service  Technician  

 

PROBLEM  

 

 

 

Motor  won't  run  

 

CAUSE  

No  power  to  machine  

Switch  not  turned  on  

Blower  impeller  jammed  

Intake  or  exhaust  blocked  

Thermal  cut  off  has  been  tripped  

  Switch  is  broken  

 

 

 

 

 

Motor  runs  but  impeller   turns  erratically  or  scrapes  

Loose  wiring  

Severe  jolt  has  caused  motor     mount  to  bend  and  impeller  to  rub    

Severe  jolt  caused  motor  to  slip     out  of  mount  and  impeller  to  rub  

 

Unit  vibrates  excessively   Accumulation  of  soil  on  impeller  

Blower  impeller  has  lost  balance  

 

Blower  impeller  has  been  bent  

Bent  motor  shaft  

See  

Above  

FS  

FS  

FS  

FS  

FS  

AST  

AST  

AST  

AST  

FS  

AST  

AST  

AST  

 

 

SOLUTION  

Plug  in  the  unit;;  check  circuit  breaker  or  fuse  

Turn  on  the  switch  

Remove  material  jamming  wheel  

Turn  machine  off  and  allow  to  cool,  then  remove  blockage  

Allow  blower  to  cool  down  and  motor  will  restart   automatically  

Call  distributor  or  Euramco  for  replacement  switch  

Check  wiring  and  tighten  as  needed  

Remove  motor  from  housing,  then  replace  or  repair   bent  motor  mount  

Remove  motor  from  housing,  then  re-­install  motor   into  mount  correctly  

Clean  blower  impeller  

Balance  or  replace  blower  impeller    

 

Replace  blower  impeller  

Replace  motor  

UB20/UB30  Owner’s  Manual  |  Euramco  Safety,  Inc.  |  SM-­‐UB20  Rev  A   6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7  |  Spare  Parts  

Contact  factory  for  replacement  parts  and  installation  instructions.    

 

Model  UB20    

Corresponding  

Bubble  No.    

1  

2  

RAMFAN  P/N  

BL011  

ST010  

Description  

Impeller  

Stator  

4  

8  

10  

11  

32a  

32b  

   

ED4001  

EZP80783007  

FZ-­9540K46  

ED4003  

ED0108  

ED0208  

 

Intake  Grill  

Retaining  Clip  

Rubber  Foot  w/washer  (4)  

Exhaust  Grill  

Junction  Box  complete  with  mounting  parts  and  cable  (115V)  

Junction  Box  complete  with  mounting  parts  and  cable  (230V)  

 

To  order  spare  parts  call  Euramco  Safety  +1.619.670.9590  or  email  [email protected]    

 

UB20/UB30  Owner’s  Manual  |  Euramco  Safety,  Inc.  |  SM-­‐UB20  Rev  A   7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model  UB30    

Corresponding  

Bubble  No.  

1  

4  

5  

10  

11  

32a  

32b  

   

RAMFAN  P/N  

ST030  

EJ4001  

BL016  

EB4001  

FZ-­9540K58  

ED0408  

ED0508  

 

Description  

Stator  

Housing  

Impeller  

Intake/  Exhaust  Grill  

Rubber  Foot  w/washer  (4)  

Junction  Box  complete  with  mounting  parts  and  cable  (115V)  

Junction  Box  complete  with  mounting  parts  and  cable  (230V)  

 

To  order  spare  parts  call  Euramco  Safety  +1.619.670.9590  or  email  [email protected]    

 

UB20/UB30  Owner’s  Manual  |  Euramco  Safety,  Inc.  |  SM-­‐UB20  Rev  A   8

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement