radiopowiadomienie rp-500 - 4 kanały
RP-501
MULTIFUNCTION FOUR CHANNEL TRANSMISSION SET
(EN)
The set consists of four channel radio transmitter and dedicated superheterodyne type receiver designed for use in radio remote control and antiburglar alarm systems. Both the transmitter (encoder) and the receiver (decoder) use microprocessor controlled input/output logic and 64-bit encryption technology.
The system operates in 433,92 MHz frequency band and features up to 500 meters operating range in open field. Wider operating range can be obtained with simple
dipole TV UHF band (ch 21-60) directional antenna with coaxial cable used in place of the standard wire antenna. One receiver may operate with up to 60
transmitters in a system. Both units are in same look like ABS plastic enclosures with different colour LED indicators. The transmitter (with red LED indicator) may
be powered either from 12VDC supply line or, due to extremely low power requirements, from internal 9V battery. The receiver (bicolour LED indicator) operates
from 12VDC supply and has four fully programmable NO/NC relay outputs connecting to the receiver's ground. The relays’ time-lapse mode of operation is user
programmable. The signalling output S (open collector type) is for external beeper device and delivers signal pulses on alarm state. The S output might also be user set
to indicate failure of radio link between transmitter and receiver. This is activated by opening jumper J1 in receiver. The receiver features TAMPER switch and built in
bicolour LED allowing necessary programming and output status indication. The transmitter’s TAMPER switch, which is connected in series with D4 input, is user
activated by cutting jumper ZT and closing input D4 to receiver's ground. It generates alarm transmission in channel 4 on opening of RP501 box. Practical operating
range of the set depends on local propagation conditions and should be tested prior to firm installation.
TRANSMITTER OPERATING MODES (selected by jumpers J1, as illustrated below)
2
1
1. Standard operation mode. Opening any of the transmitter's D1..D4 inputs triggers radio transmission lasting 15 seconds that switches to 1 second
transmissions every 1 minute interval if any of the inputs remain still opened. Transmission ends when all inputs of the transmitter are closed. Receiver
outputs reset after passing user-programmed output relay set time.
8
1
2
8
1
2
8
1
2
8
2. Prolonged transmission mode. On opening any of the D1..D4 transmitter inputs, even for a short while, prolonged pulse transmissions lasting 15 or
40 seconds (selected by jumper 7-8: closed-40s, opened-15s) are triggered. Any further triggering while in transmitting extends transmission time. If the
triggering lasts longer than the selected prolonged transmission period, the transmitter auto-switches to battery saving mode of 1 second transmission
every 1 minute interval time.
3. Radio relay operation mode. Any open-close change on the transmitter’s D1..D4 inputs triggers transmission lasting 15 or 40 seconds (as selected
by jumper 7-8 described above) with the receiver D1..D2 outputs status corresponding to the status of the transmitter’s inputs. This operating mode
allows real time monitoring of transmitter’s inputs status in the receiver.
4. Radio relay operation with cyclic update mode. The same as in mode 3 described above, with the addition of 1 second lasting update
transmission made every 80 seconds, securing that the receiver’s outputs state truly correspond to that of the transmitter in case of possible power
supply failure or radio transmission interference.
IMPORTANT! Every time a new mode of operation is selected in transmitter, memory of corresponding receiver must
transmitter(s) be learned to the receiver’s memory again (as described in points 3 & 1 of the programming procedures below).
be cleared and
If the transmitter is battery operated its voltage is monitored in all the above modes of operation. Battery voltage drop to approx. 7V level triggers low battery alarm
transmissions made every 4 minutes. The receiver signals the need of the transmitter’s battery change by blinking LED in green. After the battery is replaced the LED
blinking sets off automatically. Additionally, operation of the set in any of the above modes may be user selected to perform radio link testing. This function is
selected in transmitter by disconnecting jumper 5-6 (J1). Every 35 seconds the transmitter sends radio link test signal. If, for any reason, the receiver does not receive
any test signal within 90 seconds time span, it sets on warning by blinking red LED and generates alarm pulses at the S output (rate: 0,5s pulse/1,5s interval) . Only
one transmitter may operate with radio link testing in a system. Warning signals are generated untill any next valid transmission is received. The RP501 transmitter
operates also with Elmes made CB32 control panel and CH4H, CH8H, CH20H multichannel receivers though radio link testing mode is inactive.
12V
RECEIVER’S OPTIONS
The receiver’s four relay outputs may be user set to NC (normally closed) or NO (normally opened) operation. As standard, manufacturer’s setting is to NC operation.
To change relay(s) output mode NC-NO jumper(s) need to be appropriately set by the user. At standby, the receiver’s outputs are off and the LED lights green. When
valid transmission from the RP501 transmitter is received the D1-D4 outputs are set according to received information.
PROGRAMMING PROCEDURES
Prior to programming make sure the receiver's LED lights green, otherwise shortly disconnect power supply.
1. Programming - learning transmitter(s) to receiver's memory:
a) press the receiver's PRG switch (LED lights red) for less than 2 seconds. Releasing the switch LED continues to light red,
b) disconnect one of the D inputs of the transmitter, blinking receiver's LED confirms end of the procedure and the transmitter is in the receiver's memory.
2. Programming - setting the receiver to time-lapse output mode and reset time:
a) press the receiver's PRG switch (LED lights red) for more than 2 and less than 8 seconds. Releasing the switch LED light changes to green,
b) press shortly PRG switch again to start time-lapse count. Receiver's LED lights red.
c) when desired time has lapsed (1s up to 6 hours) press the PRG switch shortly again. The receiver's LED changes to green and after 2 seconds starts blinking
confirming end of the procedure.
By triple pressing PRG switch with intervals shorter than 2 seconds, in point 2b above, the receiver's outputs are set to latched (on/off) mode of operation so their
reset can only be made by disconnecting power supply.
3. Programming - erasing all transmitters from the receiver's memory:
Press the receiver's PRG switch (LED lights red) for more than 8 seconds, until the receiver LED starts blinking confirming end of the procedure. Memory of the
receiver is cleared. Programming new transmitter/s to the receiver can be made according to point 1 above.
INSTALLATION
S upply
Power supply ...
9-13V
_
_
+
+
As shown on the schematic wiring diagram, with all not used transmitter’s inputs shorted to
OUTPUTS Buzzer
+
ground (- DC supply voltage).
D1
S
+
D2
_
+
D3
D4 D3 D2 D1
6M 8
NC
NO
NC
NO
NC
NO
NC
NO
transmitter: p. supply 9-14 VDC or 9V battery; transm. current 10mA, standby 17uA, 64 bit - 16777216
code settings; f=433,92 MHz (≤10dBm), operation temp. -20 to +40C,
receiver: superheterodyne type with 4 relay outputs (60VA, max 1A, 128V) & output S type OC: 1A/60V,
power supply 10-15VDC (100mA min.), max. number of transmitters 60; operating temp.-20 to +40C.
_
D4
SPECIFICATION
Transmitter's
board
tamper
NC output
...or battery 9V.
Receiver's board
BAT 9V
Never both !!!
Certified by “TECHOM” security class “C”. Confirmation of Conformity No 187/2001.
Manufacturer’s limited warranty. Elmes Electronic products carry manufacturer’s one year limited warranty as from date of purchase. The warranty is limited to the replacement of faulty
original parts or repair defects of improper manufacture. Damage, faulty use or improper handling by the user or installer as well as any changes in product’s hardware or software caused by the
user or any other unauthorised person violets the warranty and all due repair costs will be charged. In all cases, the customer pays costs of delivery to and from the manufacturer of the products
to be serviced. Elmes Electronic shall not bear liability for any personal or material damage resulting from its any product direct, indirect or partial failure to operate properly.
ELMES ELECTRONIC, tel. (+4871)7845961, fax 7845963, e-mail elmes@elmes.pl
www.elmes.pl
Elmes Electronic 05.2009. All rights reserved.