Regulated by 5 to 24 volt AC/DC control signal
SLA 5/24 – governed by master thermostat
SLA 5/24 may be controlled by all systems using control
signals from 5 to 24 volts, AC or DC. When the signal
voltage is applied, the heater will switch on, and will
continue heating as long as the signal voltage is present.
SLA 5/24
SLA 5/24 Slave Module
• Governed by master thermostats XMA, ETM, DTM
and RFRM
• The slave module switches on and off in step with
the master thermostat
• Synchronous operation of the heaters provides an even
heating of the room
Specifications:
• Master input terminal for DC or AC, 5 to 24 V
• Galvanic isolation from mains supply (optocoupler)
SLA 5/24
SLA 5/24 (230/400V)
Item No.
755 222 432
El. Nr.
54 207 92
Slave module for Glamox heater series 3001
Regulated by 5 to 24 volt AC/DC control signal
Electric heating and cooling in sequence
24 V AC proportionally timed on/off
Heating
Connection box
Cooling
Glamox heaters with SLA 5/24 fitted
Regulation of room
temperature by controlling
heating and cooling in
sequence is employed by
a number of systems.
Here we show an example
where Glamox panel heaters
fitted with SLA 5/24 are
governed by a 24 V AC
proportionally timed control
signal from an ABB E21-type
thermostat.
(Corresponding thermostats
are available from several
manufacturers.)
Glamox Norge AS
P. O. box 4253 Torshov
Sandakerv. 138,
0401 Oslo.
Tel. 22 02 11 00
Fax. 22 02 11 02
www.glamox.no/
info@glamox.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising