HP AT514A rack accessory Datasheet
Add to my manuals15 Pages
HP AT514A is an Environmental Base Station that helps you monitor your data center's environment by collecting temperature and humidity data. It can be attached to individual racks or CRAH units and reports information either once every minute or up to once every 5 minutes. It's easy to mount or attach and comes with a one-year parts-only warranty (excluding batteries).
advertisement
▼
Scroll to page 2
of 15
HP Data Center Environmental Edge and HP Insight Environmental Observer QuickSpecs Overview The new HP Data Center Environmental Edge technology helps you address one of the most critical issues in today's data centers power and cooling. HP Data Center Environmental Edge is an affordable approach to monitoring your data center environment, resulting in optimal use of data center capacity and a reduction in energy costs. HP Data Center Environmental Edge measures, analyzes and visualizes data center environmental parameters, ensuring complete confidence that you're running a much more efficient data center. Why HP Data Center Environmental Edge? Resiliency: Real-time feedback on environmental changes in your data center through data center environmental visualization and customer defined alarms Energy savings: Reduces data center cooling energy up to 18% by enabling customers' data center optimization Provides insight into data center infrastructure over-provisioning Supports higher rack operating temperature and chilled water temperature through the data center environmental measurements Increased Flexibility: Adapt /upgrade the HP Data Center Environmental Edge hardware and HP Insight Environmental Observer software to meet the changing needs of your data center HP Data Center Environmental Edge bridges the gap between IT and facilities. HP Data Center Environmental Edge enables both facilities and IT manager's deeper insight into their current data center environment. For additional information, please visit: www.hp.com/go/edge HP Data Center Environmental Edge Base Stations 1. Air Pressure Base Station 2. Environmental Base Station 3. Base Station Gateway What's New DA - 13392 Worldwide — Version 2 — November 16, 2009 Page 1 QuickSpecs HP Data Center Environmental Edge and HP Insight Environmental Observer Overview Data center power visualization, including PUE Current per phase (Wye only) Power Factor per phase (Wye only) Voltage per phase (Wye L-N and Delta L-L) Total Power Average Power (period = 5min sampling interval) THD Branch circuit monitoring Current per circuit with breaker capacity and warning status Power Factor per circuit Voltage per phase Chilled water Energy Monitoring Modbus Gateway DA - 13392 Worldwide — Version 2 — November 16, 2009 Page 2 QuickSpecs HP Data Center Environmental Edge and HP Insight Environmental Observer Standard Features Wireless Network and Network and Network Security HP Data Center Environmental Edge sensor and networking devices use 802.15.4 based radios that operate in the 2.4 GHz industrial and scientific and medical (ISM) unlicensed band. The HP Data Center Environmental Edge wireless communications low bandwidth will not interfere with other wireless communications. The HP Data Center Environmental Edge wireless communications uses a mesh network topology to transfer information. HP Data Center Environmental Edge wireless systems achieve security at multiple levels: First HP Data Center Environmental Edge wireless communications are not IP-enabled; they therefore are not susceptible to external IP-based passive and active attacks. Second, HP Data Center Environmental Edge network stack uses 128bit-AES cryptograph to provide authentication and data encryption, thereby providing security against rogue admissions and snooping. HP Data Center Environmental Edge Server At the centre of the solution is the HP Data Center Environmental Edge Server. This is a HP ProLiant DL180 G6 running Microsoft Windows Server 2008, HP Insight Environmental Observer software components. NOTE: One server can support multiple HP Data Center Environmental Edge data center locations. HP Insight Environmental HP Insight Environmental Observer S/W key features include: data center environmental visualization; Observer S/W metrics tracking, alarming and historical information, including 1 year of 24x7 Technical Support and Updates. HP Data Center Environmental Edge Environmental Base Station HP Data Center Environmental Edge Environmental Base Stations are attached to individual racks or CRAH units and collect temperature and humidity data. The HP Data Center Environmental Edge Environmental Base Station is battery powered and reports temperature and humidity information either once every minute or up to once every 5 minutes based on user desired preferences. Environmental Base Stations are simple to mount or attach within the data center environment with a couple of different Mounting Options techniques, and include a one year parts only warranty (excluding batteries). Server Racks Environmental Base stations will be combined with the HP Data Center Environmental Edge Rack Sensor Array Environmental Base Stations and Rack Sensor Array can be mounted either inside the rack on outside the rack. The Rack Sensor Array is mounted down the center of both the front and rear of the rack The minimum recommended configuration is to install the base stations once every third rack. Customers can install the base station on every other rack or every rack for increased granularity of data CRAH/CRAC (Computer Room Air Handlers / Computer Room Air Conditioning) One Environmental Base Station and the Plenum Rated Sensor Array will be installed in each CRAH unit Environmental Base Stations do not require the customers' CRAH/CRAC units to be modified Other Locations Environmental Base Stations can be located anywhere that the customers wants to gain insight into a specific locations' temperature and humidity DA - 13392 Worldwide — Version 2 — November 16, 2009 Page 3 QuickSpecs HP Data Center Environmental Edge and HP Insight Environmental Observer Standard Features HP Data Center HP Data Center Environmental Edge Rack Sensor Array contains 3 thermistors to measure rack intake Environmental Edge Rack and 3 thermistors to measure rack exhaust. Sensor Array NOTE: One year parts only warranty. NOTE: Must be combined with AT516A Environmental Base Station HP Data Center HP Data Center Environmental Edge Plenum Rated Sensor Array contains 2 plenum rated thermistors Environmental Edge and plenum rated wiring. Plenum Rate Sensor Array NOTE: One year parts only warranty. NOTE: Must be combined with AT516A Environmental Base Station HP Data Center Environmental Edge Air Pressure Base Station HP Data Center Environmental Edge Air Pressure Base Station assesses the air pressure differential in raised floor environments. HP recommends one Air Pressure Base Station per 50 m2 / 500 ft2 of data center floor space. NOTE: One year parts only warranty (excluding batteries). HP Data Center HP Data Center Environmental Edge Base Station Gateway provides the wireless communication with the Environmental Edge Base HP Data Center Environmental Edge Base Stations and transmits the data to the HP Data Center Station Gateway Environmental Edge server. HP recommends at least two Base Station Gateways per solution. One Base Station Gateway pair supports up to 200 base stations. Multiple Base Station Gateway pairs can co-exist in one data center. NOTE: One year parts only warranty (excluding batteries). NOTE: Regional SKU exists Recommended Base Configuration NOTE: The installation of the HP Data Center Environmental Edge recommended base configuration does not require any data center downtime to implement. One HP Data Center Environmental Edge Server or server with minimum 4 GB of memory and 250GB of RAID 1 storage One HP Insight Environmental Observer S/W One Base Station Gateways per 200 base stations, N+1 configuration One Environmental Base Station and Plenum Rated Sensor Array per CRAH/CRAC One Environmental Base Station and Rack Sensor Array per three racks One Air Pressure Base Station per 500 ft2/50 m2 of data center floor space DA - 13392 Worldwide — Version 2 — November 16, 2009 Page 4 QuickSpecs HP Data Center Environmental Edge and HP Insight Environmental Observer Standard Features HP Data Center Environmental Edge Optional Base Stations HP Data Center Environmental Edge Energy Base Station HP Data Center Environmental Edge Energy Base Station measures kWh (Kilowatt Hours) consumed, Power, Power Factor, Voltage, Current, THD on each electrical line where installed. Two variants of the energy meter exist, 208v or 277/480v version with either 200A or 600A split core CTs. NOTE: One year parts only warranty (excluding batteries). NOTE: Energy Base Stations must be installed by a local licensed electrician. HP Data Center HP Data Center Environmental Edge 200A Current Base Station measures an electrical line true RMS Environmental Edge 200A current from 0 - 200A. Current Base Station NOTE: One year parts only warranty (excluding batteries). HP Data Center HP Data Center Environmental Edge Flow Meter Base Station is a non-intrusive ultrasonic flow meter to Environmental Edge Flow measure chilled water flow. Meter Base Station NOTE: One year parts only warranty (excluding batteries). HP Data Center Environmental Edge Water Leak Detection Base Station HP Data Center Environmental Edge Water Leak Detection Base Station detects liquid leakage. NOTE: One year parts only warranty (excluding batteries). HP Data Center HP Data Center Environmental Edge Rack Door Position Base Station will alarm the customer when the Environmental Edge Rack rack door is accessed. Door Position Base Station NOTE: One year parts only warranty (excluding batteries). HP Data Center HP Data Center Environmental Edge Rack Sensor Array contains 3 thermistors to be place anywhere the Environmental Edge Three customer wants detailed thermal information Point Sensor Array NOTE: One year parts only warranty (excluding batteries). NOTE: Must be combined with AT516A Environmental Base Station DA - 13392 Worldwide — Version 2 — November 16, 2009 Page 5 QuickSpecs HP Data Center Environmental Edge and HP Insight Environmental Observer Standard Features HP Data Center Environmental Edge Universal Base Station HP Data Center Environmental Edge Universal Base Station can be attached to any monitoring device which produces a 4-20mA signal / 0-10v signal. NOTE: One year parts only warranty (excluding batteries). NOTE: This product can only be procured through the HP specials process, please contact your local HP Pre-sales or EAM. HP Data Center HP Data Center Environmental Edge Branch Circuit Monitoring Base Station comes in up to 208v or Environmental Edge 240v, and 42 circuit and 84 circuit wall mount, or 42 circuit sub-floor panels Branch Circuit Monitoring Base Station NOTE: One year parts only warranty (excluding batteries). NOTE: BCM Base Stations must be installed by a local licensed electrician. HP Data Center Environmental Edge Chilled Water Energy Base Station HP Data Center Environmental Edge Chilled Water Energy Base Station measures chilled water flow rate and temperature of both the supply and return lines NOTE: One year parts only warranty (excluding batteries). DA - 13392 Worldwide — Version 2 — November 16, 2009 Page 6 QuickSpecs HP Data Center Environmental Edge and HP Insight Environmental Observer Configuration Information HP Data Center Environmental Edge Configuration Step 1: Determine base quantity needed for the base recommended configuration: configuration One HP Data Center Environmental Edge Server One HP Insight Environmental Observer S/W Two HP Base Station Gateways minimum, one per 200 base stations, N+1 configuration One Environmental Base Station and Plenum Rated Sensor Array per CRAH/CRAC One Environmental Base Station and Rack Sensor Array per three racks One Air Pressure Base Station per 500 ft2/50 m2 of data center floor space One HP Data Center Edge Installer kit per 10,000 ft2/1000 m2 Step 2: Determine extra base stations required for increased granularity Step 3: Determine optional base stations HP Data Center Environmental Edge Base SKUs Models HP Data Center Environmental Edge Server NOTE: Includes HP ProLiant DL180 G6, 6 GB Memory, Microsoft Server 2008 standard. NOTE: HP Data Center Environmental Edge Server can manage several Base Station gateway networks, deployment license based on installed floor space. NOTE: For additional information on the HP ProLiant DL180 G6, please see the following: http://h18000.www1.hp.com/products/quickspecs/13248_div/13248_div.html HP Insight Environmental Observer S/W NOTE: Includes 1 year of 24x7 SW Technical Support and Updates. HP Data Center Environmental Edge Environmental Base Station HP Data Center Environmental Edge Rack Sensor Array HP Data Center Environmental Edge Air Pressure Base Station HP Data Center Environmental Edge Base Station Gateway HP Data Center Environmental Edge Installer Kit DA - 13392 Worldwide — Version 2 — November 16, 2009 AV865A AT515A AT516A AT517A AT518A AT519A AT533A Page 7 QuickSpecs HP Data Center Environmental Edge and HP Insight Environmental Observer Configuration Information HP Data Center Environmental Edge Optional SKUs HP Data Center Environmental Edge 208v/200A Energy Base Station HP Data Center Environmental Edge 200A Current Base station HP Data Center Environmental Edge Flow Meter Base Station HP Data Center Environmental Edge Water Leak Detection Base Station HP Data Center Environmental Edge 208V/600A Energy Base Station HP Data Center Environmental Edge Rack Door Position Base Station HP Data Center Environmental Edge Three Point Sensor Array HP Data Center Environmental Edge Plenum Rated Sensor Array HP Data Center Environmental Edge 480v/200A Energy Base Station HP Data Center Environmental Edge 480v/600A Energy Base Station HP Data Center Environmental Edge Modbus Base Station HP Data Center Environmental Edge Chilled Water Energy Base Station HP Data Center Environmental Edge Dual Chilled Water Energy Base Station HP Data Center Environmental Edge 208v 42 Circuit Wall Mount BCMS Base Station HP Data Center Environmental Edge 208v 84 Circuit Wall Mount BCMS Base Station HP Data Center Environmental Edge 208v 42 Circuit Subfloor BCMS Base Station HP Data Center Environmental Edge 240v 42 Circuit Wall Mount BCMS Base Station HP Data Center Environmental Edge 240v 84 Circuit Wall Mount BCMS Base Station HP Data Center Environmental Edge 240v 42 Circuit Subfloor BCMS Base Station HP Data Center Environmental Edge Current Sensing Relay Base Station HP Data Center Environmental Edge Base Station Gateway (EU) HP Data Center Environmental Edge Base Station Gateway (APJ:UK) HP Data Center Environmental Edge Base Station Gateway (AUS) HP Data Center Environmental Edge Base Station Gateway (CN) HP Data Center Environmental Edge Base Station Gateway (JPN) HP Data Center Environmental Edge Base Station Gateway (UK) DA - 13392 Worldwide — Version 2 — November 16, 2009 AT521A AT520A AT522A AT524A AT527A AT525A AT514A AT526A AT530A AT531A AT532A AT534A AT535A AT536A AT537A AT538A AX723A AX724A AX725A AX726A AT519A#B19 AT519A#ARS AT519A#ABG AT519A#AKM AT519A#ABJ AT519A#ACC Page 8 QuickSpecs HP Data Center Environmental Edge and HP Insight Environmental Observer Support & Service Service and Support Offerings (HP Care Pack Services) NOTE: The HP Care Pack service part numbers below for the HP Data Center Environmental Edge system, cover the server blade and all HP branded hardware options qualified for the server, purchased at the same time or afterwards, internal to the server. Support Plus Support Plus 24, 1 Year Support Plus 24, 3 Years Installation & Startup HP Installation & Startup Service for HP Data Center Environmental Edge NOTE: Provides for an integrated hardware and software implementation that includes remote service planning, onsite deployment of hardware and software, installation verification testing and customer orientation. Hardware deployment covers the installation of a single HP Data Center Environmental Edge server, Ethernet network interconnect, and specified sensor options. Software deployment covers the installation and configuration of sensors in the HP Data Center Environmental Edge Software. DA - 13392 Worldwide — Version 2 — November 16, 2009 HA110A1 HA110A3 HA114A1 Page 9 HP Data Center Environmental Edge and HP Insight Environmental Observer QuickSpecs Technical Specifications Wireless RF Specifications Band Data rate maximum Maximum RF output power Base Station Gateway Antenna Node to Node Distance Regulatory Notices 2.4 GHz, ISM unlicensed band IEEE 802.14.5 MAC 250 Kbps 0dBm +0 dBi omni-directional antenna +2.2dBi Typical 15m/ 50ft FCC Part 15, Subpart C, 15.247 U62-SRS100 and U62-THERM Industry Canada 7265A-SRS100 and 7265A-THERM CE Marking EN 300 328; V1.7.1 (2006-05) and EN 300 440-2 V1.1.2 (2004-07) HP Data Center Environmental Edge Environmental Base Station Housing Mounting Options Connectors Power Requirements Internal Sensed Data: Dew Point Internal Sensed Data: Temperature Sensor Environmental DA - 13392 ABS plastic L 3.6" x W 2.5" x H 1.2" (L 91.5mm x W 63.5mm x H 30.5mm) Zip Tie: (4 holes) Accommodates up to 0.18" (4.6mm) width 3M Command Strips Screws: (4 holes) 1.25" x 1.7" (31.75mm x 43.2mm) - - fits up to #6 Machine Screws HP 14 position I/O connector for use with HP Data Center Environmental Edge Rack Sensor Array 4 Approved Batteries (see Approved Batteries Technical Spec) Typical Life @ 5 min Sample Rate: 5 to 7 years Typical Life @ 1 min Sample Rate: 4 years Operating Range: 50ºF-95ºF (10ºC - 35ºC), 20%RH - 80%RH Accuracy: Nominal +0.86ºF -0.82ºF (+0.48ºC - 0.46ºC) Accuracy over time: After 1 year +0.92ºF - -0.88ºF (0.51ºC - -0.49ºC) After 2 years +0.99ºF - -0.94ºF (.0.55ºC - -0.52ºC) After 3 years +1.06ºF - -0.99ºF (0.59ºC - -0.55ºC) Accuracy: ±0.5ºF (±0.3ºC) Stability: Negligible Operating Range: 32ºF to 122ºF (0ºC to 50ºC) Time Constant: 231sec moving air (typical)C5 Operating: 32 to 104degF (0 to 40degC) Storage: 14ºF to 140ºF (-10ºC to 60ºC)On-board AC/DC Operating Temperature: 32ºF to 122ºF (0ºC to 50ºC) Storage Temperature: 14ºF to 140ºF (-10ºC to 60ºC) Worldwide — Version 2 — November 16, 2009 Page 10 QuickSpecs HP Data Center Environmental Edge and HP Insight Environmental Observer Technical Specifications HP Data Center Connectors Environmental Edge Base Station Gateway Power requirements Ethernet Environmental HP Data Center Connectors Environmental Edge Rack Sensor Array & Three Mounting Options Point Sensor Array External Temperature Sensors HP Data Center Environmental Edge Plenum Rated Sensor Array Connectors Mounting Options External Temperature Sensors DA - 13392 RJ45 Ethernet Connection; 2.1x5.5mm 5.0VDC Jack RPSMA Antenna connector Gateway node requires 5.0VDC (±5%) via supplied power adapter requiring 110-240VAC (50~60Hz) power source (<2W) Supplied with 2 approved batteries (See Approved Battery Technical Spec) for battery backup during 5V power loss. RJ45 Ethernet 10Base-T or 100Base-TX (auto-sensing) Ethernet Network Security:SSL v3, SSH2, Rijndael 256-bit encryption, password protection, IP address filtering, locking features, hardened OS and stack Operating: 32 to 104ºF (0 to 40ºC) Storage: 14ºF to 140ºF (-10ºC to 60ºC) HP 14 position I/O connector for use with HP Data Center Environmental Edge Rack Sensor Array Rack Sensor Array: 3M Command strips to front and rear rack doors. If no doors then side of rack Three Point Sensor Array: 3M Command strips to attach where the customer needs temperature and humidity visualization Rack Sensor Array: 6 external thermistors Three Point Sensor Array: 3 external thermistors Temperature Range: 32ºF to 122ºF (0ºC to 50ºC) Temperature Accuracy 10 to 43ºC: ±0.5ºF (±0.3ºC) Temperature Accuracy 0 to 10 and 43 to 50ºC: ±1.2ºF (±0.7ºC) Time Constant: 30sec moving air; 60sec static air (typical) Resolution: ±0.02ºF at 77ºF (±0.01ºC at 25ºC) Stability: Typically ± 0.0056ºF (0.0031ºC) over 5 years Thermistors: 10k ohm, Type J Curve Thermistor Time Constant: 60sec static air; 30sec moving air (typical) HP 14 position I/O connector for use with HP Data Center Environmental Edge Rack Sensor Array 3M Command strips to front and rear rack doors. If no doors then side of rack 2 plenum rated thermistors attached to plenum rated wire Temperature Range: 32ºF to 122ºF (0ºC to 50ºC) Temperature Accuracy 10 to 43ºC: ±0.5ºF (±0.3ºC) Temperature Accuracy 0 to 10 and 43 to 50ºC: ±1.2ºF (±0.7ºC) Time Constant: 30sec moving air; 60sec static air (typical) Resolution: ±0.02ºF at 77ºF (±0.01ºC at 25ºC) Stability: Typically ± 0.0056ºF (0.0031ºC) over 5 years Thermistors: 10k ohm, Type J Curve Thermistor Time Constant: 60sec static air; 30sec moving air (typical) Worldwide — Version 2 — November 16, 2009 Page 11 HP Data Center Environmental Edge and HP Insight Environmental Observer QuickSpecs Technical Specifications HP Data Center Environmental Edge Air Pressure Base Station Housing Mounting Options Connectors Power Requirements Sensed Data Pressure Sensor Performance Sensed Data High and Low Pressure Ports Environmental HP Data Center Environmental Edge Universal Base Station Housing Mounting Options Power Requirements Analog inputs DA - 13392 ABS plastic L 4.5" x W 2.6" x H 1.4" (L 114.3mm x W 66.1mm x H 35.6mm) Screw: (4 holes) 1.7" x 1.3" (43.2mm x 33.1mm) - fits up to #6 Machine Screws Zip Tie: (4 holes) Accommodates up to 0.18" width 3M Command Strips 1/8" Barbed Hose Fitting for High and Low Pressure Differential connections 4 Approved Batteries (see Approved Batteries Technical Spec) Typical battery life @ 5 min Sample Rate: 5 to 7 years Typical battery Life @ 1 min Sample Rate: 4 years Internal 0 to 0.5 in-H2O Air Pressure Differential (room vs. plenum) Differential Pressure Range: 0 to 0.5" H2O (0 to 125 Pa) Zero point accuracy: 0.002" H2O (0.5Pa) Span Accuracy: ±3.0% of reading Resolution: ±0.001"H2O (±0.25 Pa) Offset Stability: <0.1 Pa per year 0.170 inch inner diameter tubing; use with up to 6 feet of tubing, cut to length as required during installation (supplied with node; plenum rated UL94V2 tubing). Longer tubing length is allowable, but sensor accuracy and response time may increase; use pressure diffuser tip to prevent foreign contaminates entering sensor (supplied with node) Operating: 32 to 104ºF (0 to 40ºC) Storage: 14ºF to 140ºF (-10ºC to 60ºC) ABS plastic L 3.6" x W 2.5" x H 1.2" (L 91.5mm x W 63.5mm x H 30.5mm) Screws: (4 holes) 1.25" x 1.7" (31.75mm x 43.2mm) - fits up to #6 Machine Screws Zip Tie: (4 holes) Accommodates up to 0.18" width 3M Command Strips 4 Approved Batteries (see Approved Batteries Technical Spec) Typical Battery Life @ 5 min Sample Rate: 5 to 7 years Typical Battery Life @ 1 min Sample Rate: 4 years 4-20mA: Accuracy: ±1.15% Full Scale Resolution 0.03%v 0-10V: Accuracy: ±1.53% Full Scale Resolution 0.03% Worldwide — Version 2 — November 16, 2009 Page 12 HP Data Center Environmental Edge and HP Insight Environmental Observer QuickSpecs Technical Specifications HP Data Center Accuracy Environmental Edge 200A Range Current Base Station Console Display Environmental Installation ±0.5% (from 1 - 100% FSO) 0 - 200A RMS 2 significant digits for volumetric flow 10°C to 40°C / 20% to 95% RH, non-condensing Licensed electrician, circuit downtime not required HP Data Center Flow Range Environmental Edge Flow Meter Base Station Installation Console Display 0 to 400fps (based on typical industrial pipe applications this equates to no limitation in terms of volumetric flow) Non-intrusive ultrasonic flow measurement Volumetric Flow, range adjusted at installation for min/max Limits 1/3200th of the installed range 0 significant digits for volumetric flow Steel, Copper, Plastic (2-16" diameter) ±2.8% Resolution Console Display Pipe materials Accuracy HP Data Center Environmental Edge Water Leak Detection Base Station Leak Detection Optical sensor detects liquid contacting surface Adjustable Height -13ºF to 176ºF (-25ºC to 80ºC) HP Data Center Environmental Edge Installer kit Kit Contents Barcode Scanner Label Maker Wire Strippers Plenum Rated Zip Ties Command Strips Cable routing clips Thermistor mounting clips Return shipping label Battery Technical Information Approved Battery Battery Life Expectations ENERGIZER AA LITHIUM, MODEL# L91, 1.5VDC Typical Battery Life @ 5 min Sample Rate: 5 to 7 years Typical Battery Life @ 1 min Sample Rate: 4 years HP BCMS Components Sensor Operating Temperature Includes 42 or 84 Split Core CT's, 60 amp rated each Includes 2 or 4 CT to Ribbon Cable Interface Box Includes 1 data acquisition board Mounting and Installation Install data acquisition module inside electrical box or in remote electrical box. Voltage connections are routed to data acquisition module. Split Core CT's are connected to Ribbon Cable Interface boxes, which then convert to ribbon cables connected to the data acquisition board. Modbus connection uses Modbus RTU 4wire multi-drop. DA - 13392 Worldwide — Version 2 — November 16, 2009 Page 13 QuickSpecs HP Data Center Environmental Edge and HP Insight Environmental Observer Technical Specifications Power Requirements Sensed Data 110-240VAC, 4 wire Data acquisition board can be powered in parallel or separately. HP EIO software will provide the following data points: Current per circuit with breaker capacity and warning status Power Factor per circuit Voltage per phase HP Energy Meter Accuracy* Power per circuit, per phase, and total with warning status Current (amperage): +/-2% Voltage (volts): +/-2% Power (kw): +/-3% Installation Local licensed electrician required for installation and *onsite calibration Components Includes HP wireless base station, SquareD ION6200 in single HDM enclosure, and 3 Split Core CT's, both UL and CE rated Mounting and Installation HDM Dimensions: 11.92"x7.5"x7.88" Wall mount ION6200 enclosure. Voltage and CT connections are routed from source to HDM enclosure. Power Requirements 110-480VAC*, 50/60Hz, up to 2400amps per circuit*, 3 or 4 wire, Wye or Delta. * Depending on model ordered Sensed Data HP EIO software will provide the following data points: Accuracy* Installation Current per phase (Wye only) Power Factor per phase (Wye only) Voltage per phase (Wye L-N and Delta L-L) Total Power Average Power (period = 5min sampling interval) THD Current (amperage): +/-1% Voltage (volts): +/-1% Power (kw): +/-2% Local licensed electrician required for installation and *onsite calibration HP Chilled Water Energy Components Includes HP wireless base station, Ultrasonic Flow Meter with remote Meter transducers, and 2 pipe temperature RTD's Mounting and Installation Ultrasonic transducers are clamped directly to the chilled water pipe surface. Pipe temperature RTD's are clamped directly to the chilled water pipe surfaces. Control box and wireless node mounted remotely. Power Requirements 110-240VAC, 50/60Hz Sensed Data HP EIO software will provide the following data points: Supply Volumetric Flow Rate Supply Temperature Return Temperature Accumulated Energy DA - 13392 Worldwide — Version 2 — November 16, 2009 Page 14 HP Data Center Environmental Edge and HP Insight Environmental Observer QuickSpecs Technical Specifications Environment-friendly Products and Approach Accuracy Volumetric Flow: +/-3% Temperature: +/-0.2degC Energy: +/-3% End-of-life Management and Recycling Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. © Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. DA - 13392 Worldwide — Version 2 — November 16, 2009 Page 15
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project