User manual | Aermec FCX A, AS, ACT, APC, B, U, UA, UE, FCXI AS, U, ACT, Omnia HL HL, HL M, HL N, HL NM, HL L, HL LM, HL PC, HL PCM, HL S, HL SM Fan Coils, DUALJET Fan Coil Product Details

User manual | Aermec FCX A, AS, ACT, APC, B, U, UA, UE, FCXI AS, U, ACT, Omnia HL HL, HL M, HL N, HL NM, HL L, HL LM, HL PC, HL PCM, HL S, HL SM Fan Coils, DUALJET Fan Coil Product Details

Add to My manuals
75 Pages

The FCX A, FCX AS, FCX ACT, FCX APC, FCX B, FCX U, FCX UA, FCX UE Fan Coils are designed to maintain the set temperature over time, ensuring very low sound levels. The FCXI AS, FCXI U, FCXI ACT Fan Coils are equipped with inverter Brushless motor for high efficiency and continuous air flow rate modulation to increase comfort and save energy. The DUALJET Fan Coil makes rooms more comfortable by directing air to provide uniform temperature distribution throughout. The Omnia HL, Omnia HL M, Omnia HL N, Omnia HL NM, Omnia HL L, Omnia HL LM, Omnia HL PC, Omnia HL PCM, Omnia HL S, Omnia HL SM Fan Coils are for both horizontal and vertical installations.

advertisement

Aermec Fan Coils FCX, FCXI, DUALJET and Omnia HL: Product Details | Manualzz

FCX

Fan coils

Universal and floor installation

Aermec

participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com

FCX_A housing: RAL 9002 head and feet: RAL 7044

ZX

FCX-U

Features

Fan coils for heating, cooling, and dehumidifying.

FCX is designed to maintain in time the set temperature, ensuring very low sound levels. Installed in any type of plant

2/4 tubes and in combination with any of the heat generator even at low temperatures.

Thanks to the availability of different versions, with front or lower air intake, with standard battery or increased, for horizontal or vertical installation, it is easy to choose the optimal solution for any need.

- Vertical installation:

FCX-A: vertical free-standing with switch

FCX-AS: vertical free-standing without switch. Compatible with the VMF system

FCX-ACT: vertical free standing with electronic thermostat

FCX-APC: (FCX 22, 24, 32, 34, 36, 42, 44, 50, 54, 56, 62,

64, 82, 84) vertical free-standing with electronic thermostat and Plasmacluster purifier

FCX-B: front suction, without selector. Compatible with the VMF system

- Vertical and horizontal installation:

FCX-U: universal floor or wall/ceiling mounting.

Adjustable air distribution grille, except for models 62,

64, 82, 84 and 102. Compatible with the VMF system

FCX-UA: universal floor or wall/ceiling mounting. Grille with fixed fins. Compatible with the VMF system

FCX-UE: universal floor or wall/ceiling mounting with direct expansion coil. Adjustable air distribution grille, except for models 62, 82 and 102.

• Versions standar coil (FCX 17, 22, 32, 36, 42, 50, 56, 62,

82 and 102)

• Versions increased coil (FCX 24, 34, 44, 54, 64, and 84)

• 3-speed ventilating unit

• Full compliance with the accident prevention standards

• Rounded line

• Automatic fan coil switch-off with closure of the air distribution grille

• Broad range of controls

• Metallic protective cabinet with rustproofing polyester paint

• Quiet operation

• Low loss of charge in the heat exchange batteries

• Electric motors with permanently inserted condensers

• Ease of installation and maintenance

• Air filter easy to remove and clean

• Extractable shrouds for easy, effective cleaning

• Water connections can be reversed during installation phase

VERSION

FCX A

FCX AS

FCX ACT

FCX APC

17

17

17

-

22

22

22

22

24

24

24

24

32

32

32

32

34

34

34

34

36

36

36

36

42

42

42

42

AVAILABLE SIZES

44 50

44

44

44

50

50

50

54

54

54

54

56

56

56

56

62

62

62

62

64

64

64

64

82

82

82

82

84

84

84

84

102

102

102

-

FCX B

17 22 24 32 34 36 42 44 50 54 56 62 64 82 84 102

FCX U

FCX UA

FCX UE

Accessories

17

17

-

22

22

22

24

24

-

32

32

32

34

34

-

36

36

-

42

42

42

44

44

-

50

50

50

54

54

-

56

56

-

62

-

62

64

-

-

82

-

82

84

-

-

102

-

102

AMP: kit for the wall mounting installation of versions FCX U and UE.

BC: Auxiliary condensate drip tray. Use the BC 5-6 tray accessory if horizontal, or BC 4 if vertical.

BV: Single row hot water coil. Not available for

4-row versions or those with Plasmacluster.

DSC4: Condensate drainage device for use when natural run-off is not possible.

PC: Sheet metal panel to close rear of unit.

RX: Armoured electric coil with safety thermostat. (Requires a thermostat with heater management). Not available for 4-row versions or those with Plasmacluster.

SE: Manually operated fresh air intake louver.

SIT 3 - 5: Thermostat Interface Cards. They allow the creation of a network of fan coils (max. 10) commanded by a central control panel (selector or thermostat).

SIT3: commands the 3 fan speeds and must be installed on each fan coil of the network; receives the commands from the selector or the

SIT5 card.

SIT5: commands the 3 fan speeds and up to 2 valves (four pipes systems); sends the commands of the thermostat to the fan coils network.

SW3: water temperature probe that gives the automatic season change feature to electronic thermostats supplied with water-side change over.

SWA: SWA external probe accessory (length L =

6m). The probe detects the temperature of the ambient air if connected to the connector (A) of the panel FMT21; the ambient air temperature probe incorporated in the panel is automatically deactivated. Detects the temperature of the water in the system, for ventilation consent, if connected to the connector (W) of the FMT21 panel. Two SWA probes can be connected to the panel FMT21 simultaneously.

VCF: the kit contains a motorised 3-way valve with insulating shell, plus coupling and pipes in insulated copper. For 3/4-row and 1-row coils (BV). Combine the SW3 probe with FCX ACT, too. Versions with

230V and 24V~50Hz power supply.

VCFD: Kit consisting of powered 2-way valve, copper couplings and pipes. For 3/4-row and

1-row coils (BV). Combine the SW3 probe with

FCX ACT, too. Versions with 230V and

24V~50Hz power supply.

VCF_X4: The valve kits are designed for fan coil units with single coil, installed in a 4 pipe system with the "Cooling" and "Heating" circuits totally separated. The kit consists of 2 valves of

3-way 4 port connection complete with electrothermal actuators, insulating shells for the valves and associated hydraulic piping. VCF1X4L Valve kit for left hand connection fan coil units.

VCF1X4R Valve kit for right hand connection fan coil units. Power supply: 230V ~ 50Hz.

ZX: Feet for floor-standing installations for A-AS-

ACT-APC models.

Control panels(1) and VMF System(2): the characteristics are described on the appropriate card.

12

Accessories Size

17 22 24 32 34 36 42 44 50 54 56 62 64 82 84 102

PC

RX

SE

SIT

32

33

42

43

17

18

22

23

62

17

22

32

42

52

3

5

62

15X

20X

30X

40X

80X

FMT10 • FMT21

KTLM

PTI

PX • PX2 • PX2C6

PXBI• PXAI

(1)

(1)

(1)

(1) (3)

(1)

PXAE

PXAR

TF1

(1)

(1)

(1)

TPF

(1)

WMT05• WMT06 • WMT10

(1)

VMF-E4 • VMF-E4D

VMF-E2

VMF-E0 • VMF-E1

AMP

AMP20

BC

BV

4

5

6

117

122

132

142

162

DSC4

(2)

(2)

(2)

(4)

(4)

(4)

(4)

(4)

(5)(6)

(4)

(4)

(4)

(4)

(4)

(4)

SW3

SWA

VCF

VCFD

ZX

1X4L - 1X4R

(7)

2X4L - 2X4R

(7)

3X4L - 3X4R

(7)

41-4124

(7)(8)

(7)(8)

42-4224

43-4324

44-4424

(7)(8)

(7)(8)(9) •

45-4524

1-124

2-224

(7)(8)(9)

(7)(8)

(7)(8)

5

6

3-324

4-424

(7)(8)

(7)(8)(9) •

Versions

A-AS-ACT-APC-B-UA

U-UE

A-AS-ACT-APC-B-UA

U-UE

A-AS-ACT-B-U-UA-UE

AS-B-U-UA

AS-B-U-UA-UE

AS-B-U-UA-UE

AS-B-U-UA-UE

AS-B-U-UA-UE

AS-B-U-UA-UE

A-AS-ACT-APC

A-AS-ACT-APC

A-AS-ACT-APC

A-AS-ACT-APC

A-AS-ACT-APC

AS-B-U-UA-UE

AS-B-U-UA-UE

AS-B-U-UA

AS-B-U-UA

AS-B-U-UA

AS-B-U-UA

AS-B-U-UA

AS-ACT-APC-B-U-UA

AS-ACT-APC-B-U-UA

AS-ACT-APC-B-U-UA

AS-B-U-UA

AS-B-U-UA

AS-ACT-APC-B-U-UA

AS-ACT-APC-B-U-UA

AS-ACT-APC-B-U-UA

AS-B-U-UA

A-AS-ACT-APC

A-AS-ACT-APC

AS-B-U-UA

AS-B-U-UA

AS-B-UA-U(62 - 102)

AS-B-U-UA

AS-B-U-UA

AS-B-U-UA

AS-B-U-UA

AS-B-U-UA

AS-B-U-UA

AS-B-U-UA

AS-B-U-UA

AS-B-UA-U(62 - 102)

AS-B-U-UA

U-UA-UE

U-UA-UE

A-AS-ACT-APC-B-U-UA-UE

U-UA-UE

U-UA-UE

A-AS-B-U-UA-UE

A-AS-B-U-UA-UE

A-AS-B-U-UA-UE

A-AS-B-U-UA-UE

A-AS-B-U-UA-UE

A-AS-ACT-APC-B-U-UA-UE

A-AS-ACT-APC-B-UA

U-UE

A-AS-ACT-APC-B-UA

U-UE

(1)(2) The characteristics are described on the appropriate card.

(3) PX2C6, PX2 panel in multiple 6-piece pack.

(4) Accessoires is not available in the model with Plasmacluster filter

(5) The DSC4 accessory is not compatible with AMP and BC4_5_6 accessories

(6) DSC4 and accessoires VMF-system tray cannot be installed together on a single fan coil.

(7) The VCF/VCFD valve and the BC4 tray cannot be installed together on a single fan coil.

(8) = VCF4124-4224-4324-4424-4524 / VCFD124-224-324-424 they are 24V

(9) Only for the BV 1-row coil accessory.

13

Technical data

Mod.

FCX Vel.

17 22 24 32 34 36 42 44 50 54 56 62 64 82 84 102

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

(1) W H 2296 2960 3912 5354 5964 6413 6618 8600 8191 10100 9648 12919 14300 15140 17100 17019

Heating capacity (70°C)

Water flow rate

Pressure drop

Heating capacity (50°C)

Water flow rate

Pressure drop

(1)

(1)

(1)

(1)

(2)

(1)

(1)

(1)

(1)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(2) l/h kPa kPa kPa

W

W

W l/h l/h

W

W l/h l/h l/h kPa kPa kPa

M 2033 2531 3103 4065 4801 4983 5521 6930 7529 8759 8434 10942 11501 13349 14421 15242

L 1686 1906 2097 3165 3728 4188 4062 5200 5021 6241 6056 8327 8499 10771 11198 12558

H

M

201

178

260

222

343

272

470

357

523

421

563

437

581

484

754

608

718

660

886

768

846

740

1133 1254 1328 1500 1493

960 1009 1171 1295 1337

L

H

148 167 184 278 327 367 356 456 440 547 531 730 745 945 982 1101

3 6 4 20 11 13 15 22 15 23 42 17 23 21 32 43

M

L

2

1

4

3

3

1

12

8

7

5

10

8

11

6

15

9

13

6

18

9

33

19

12

7

16

9

16

11

23

15

34

24

H 1360 1770 2320 3160 3550 3800 3960 4950 4870 6100 5380 7500 8400 7960 10200 10000

M

L

L

H

M 1200 1510 1840 2400 2860 2950 3300 4140 4480 5220 4840 6430 6800 6860 8600 9000

L 990 1130 1250 2060 2220 2480 2430 3170 3000 3700 3680 4880 5040 5200 6700 7440

H

M

172

144

258

210

298

236

413

316

482

392

482

370

585

478

765

617

721

604

855

743

791

662

836

752

1092 1189 1479 1311

896 860 1259 1183

112 144 174 267 303 311 397 463 432 533 475 554 674 738 992 979

2 6 3 16 9 9 15 23 15 22 22 9 18 21 31 33

2

1

5

2

2

1

10

7

7

4

7

6

13

8

15

9

11

6

17

9

20

15

7

4

13

8

12

9

23

15

27

19

HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)

Heating capacity (70°C)

Water flow rate

Pressure drop

(3)

(3)

(3)

(3)

(3)

(3) l/h

(3) kPa

(3)

W

W

W l/h l/h kPa

H

M

L

H

M

L

H

M

1400

1200

990

123

105

87

3

2

1770

1510

1130

155

132

99

6

5

-

-

-

-

-

-

-

-

2850

2450

2030

250

215

178

16

12

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

3460

3410

2660

303

299

233

21

20

-

-

-

-

-

-

-

-

4380

3940

3220

384

346

282

35

30

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

5490

4700

3870

482

412

339

16

12

-

-

-

-

-

-

-

-

6410

6300

5300

562

553

465

15

14

-

-

-

-

-

-

-

-

6810

6230

5430

(3) kPa L 2

COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)

Total cooling capacity

(4)

(4)

W

W

H

M

1000

840

3

1500

1220

-

1730

1370

8

2400

1840

-

2800

2280

-

2800

2150

14

3400

2780

-

4450

3590

21

4190

3510

-

4970

4320

-

4600

3850

10

4860

4370

-

6350

5210

11

6910

5000

-

8600

7320

13

7620

6880

597

547

476

19

16

Sensible cooling capacity

Water flow rate

Pressure drop

Air flow rate

Fans

(4)

(4)

(4)

(4)

(4)

(4)

(4)

(4)

(4)

(4)

W

W

W

W l/h l/h l/h kPa kPa kPa m

3

/h m

3

/h m

3

/h type

L

H

M

L

H

M

L

H

M

L

H

M

L

650 840 1010 1550 1760 1810 2310 2690 2510 3100 2760 3220 3920 4290 5770 5690

830 1240 1380 1900 2130 2200 2760 3300 3000 3540 3500 3980 5030 5680 5780 5530

690 1000 1090 1570 1720 1820 2110 2640 2540 3060 3070 3300 4100 3780 4870 5350

510

172

144

112

3

2

1

200

160

110

670

258

210

144

6

5

3

290

220

140

760

298

236

174

3

2

1

290

220

140

1110

413

316

267

28

17

13

450

350

260

1250

482

392

303

14

10

6

450

350

260

1280

482

370

311

28

17

13

450

350

260

1630

585

478

397

14

10

7

600

460

330

1960

765

617

463

40

27

16

600

460

330

1790

721

604

432

19

14

8

720

600

400 centrifugal

2170

855

743

533

26

21

12

720

600

400

2120

791

662

475

38

28

15

720

600

400

2440

836

752

554

17

14

8

920

720

520

3060

1092

896

674

13

9

6

720

520

2970

1189

860

738

22

12

9

2800

1479

1259

4420

1311

1183

920 1140 1140 1300

930

700

992

30

22

15

930

700

979

37

31

22

1120

900

Absorbed power

Max. input current

Sound power level

Sound pressure level

Water content

Coil connections

(5)

(5)

(5)

(6)

(6)

(6) n°

W

W

W

(A) dB(A) dB(A) dB(A) dB(A) dB(A) l dB(A)

ø (4R)

ø (3R)

ø (1R)

H

M

L

H

M

L

H

M

L

H

45

38

31

37

30

1

35

29

19

1

25

22

19

1

33

29

25

2

44

33

25

2

44

34

28

2

44

33

25

2

57

43

30

2

57

43

30

2

67

46

34

2

76

52

38

2

76

52

38

3

82

61

40

3

91

60

38

3

106

80

59

3

106

80

59

3

131

100

80

0,16 0,12 0,25 0,21 0,45 0,21 0,28 0,51 0,35 0,36 0,35 0,40 0,48 0,49 0,62 0,58

50

43

31

42

35

51

46

35

43

38

48

41

34

40

33

48

41

36

40

33

48

41

34

40

33

51

44

37

43

36

55

50

41

47

42

56

51

42

48

43

56

53

44

48

45

56

51

42

48

43

57

51

42

49

43

57

51

44

49

43

61

56

51

53

48

61

57

51

53

49

66

61

56

58

53

23

0,6

-

1/2"

23

0,8

-

1/2"

1/2" 1/2"

V3 V3

27

1,0

3/4"

-

-

V3

26

1,1

-

1/2"

1/2"

V3

28

1,5

3/4"

-

-

V3

26

1,5

-

3/4"

1/2"

V3

29

1,5

-

3/4"

1/2"

V3

33

1,9

3/4"

-

-

V3

34

1,5

-

3/4"

1/2"

V3

36

1,9

3/4"

-

-

V3

34

1,9

-

3/4"

1/2"

V3

34

2,5

-

3/4"

1/2"

V3

36

3,4

3/4"

-

-

V3

43

2,5

-

3/4"

1/2"

V3

43

3,4

3/4"

-

-

V3

48

2,5

-

3/4"

1/2"

V3

Speed connected

M

L

V2

V1

V2

V1

V2

V1

V2

V1

V2

V1

V2

V1

V2

V1

V2

V1

V2

V1

V2

V1

V2

V1

V2

V1

V2

V1

V2

V1

V2

V1

V2

V1

Power supply

230V/1/50Hz

H max. speed; M med. speed; L min. speed

Heating mode

2 pipes system configuration

(1) Room air temperature 20°C b.s.; Inlet water temperare 70°C; ΔT water 10°C

2 pipes system configuration (EUROVENT)

(2) Room air temperature 20°C b.s.; Inlet water temperare 50°C; Water flow rate as in cooling mode

4 pipes system configuration (with additional heat exchanger) (EUROVENT)

(3)Room air temperature 20°C b.s.; Inlet water temperare 70°C; ΔT water 10°C

Cooling mode (EUROVENT)

(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperare 7°C; DT water 5°C

(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2

(6) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m

Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

14

Dimensions and Weight

B

C

B

C

B C

A

A

A

D

ZX accessoires

(standard and increased coil)

FCX_A

FCX_AS

FCX_ACT

FCX_APC

Mod FCX (A - AS - ACT - APC)

Height with feet

Width depth

Feet height

Weight (without feet)

Mod FCX (U - UE)

Height

Width depth

Weight

Mod FCX (UA)

Height

Width depth

Weight

Mod FCX (B)

Height

Width depth

Weight

FCX_U 17-22-32-36-42-50-56 (standard coil)

FCX_U 24-34-44-54 (increased coil)

FCX_UE 22-32-42-50 (standard coil)

A mm

B mm

C mm

D mm kg

A mm

B mm

C mm kg

A mm

B mm

C mm kg

A mm

B mm

C mm kg

17

563

640

220

105

13

17

520

640

220

13

17

490

640

220

13

17

490

640

220

13

22 / 24

563

750

220

105

15

22 / 24

520

750

220

15

22 / 24

490

750

220

15

22 / 24

490

750

220

15

32/34/36

563

980

220

105

20

32/34/36

520

980

220

20

32/34/36

490

980

220

20

32/34/36

490

980

220

20

42/44

563

1200

220

105

24

42/44

520

1200

220

24

42/44

490

1200

220

24

42/44

490

1200

220

24

FCX_B

FCX_UA 17-22-32-36-42-50-56 (standard coil)

FCX_UA 24-34-44-54 (increased coil)

FCX_U 62-82-102 (standard coil)

FCX_U 64-84 (increased coil)

FCX_U 62-82-102 (standard coil)

50/54/56

563

1200

220

105

24

50/54/56

520

1200

220

24

50/54/56

490

1200

220

24

50/54/56

490

1200

220

24

62 / 64

590

1320

220

34

62/64

688

1320

220

125

34

62/64

590

1320

220

34

82/84

688

1320

220

125

34

82/84

590

1320

220

34

82 / 84

590

1320

220

34

102

590

1320

220

34

102

688

1320

220

125

34

102

590

1320

220

34

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italy

Telephone 0442633111 - Telefax 044293577 www.aermec.com

15

FCXI

Fan coils with Brushless Inverter motor (EC)

Universal and floor installation

Aermec

participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com

FCXI A housing: RAL 9002 head and feet: RAL 7044

FCXI U

• ENERGY SAVINGS OF 50% COMPARED WITH A FAN

COIL WITH TRADITIONAL 3-SPEED MOTOR

• VERY QUIET OPERATION

• TOTAL COMFORT: REDUCED TEMPERATURE AND

HUMIDITY VARIATIONS IN THE AIR-CONDITIONED

ROOMS

Characteristics

Fan coils with with inverter technology, for heating, cooling and dehumidifying, specific to work in sensible environment.

Equipped with inverter Brushless motor for an high effciency and a continuos air flow rate modulation in order to increased comfort and guarantee electric saving. The inverter motor allows a better air temperature regulation on based on the real indoor envirorement requirements without temperature swinging..

The FCXI are the ideal solution for 2/4-pipe systems and for tertiary and commercial installations.

Thanks to the availability of different versions, with front or lower air intake, with standard battery or increased, for horizontal or vertical installation, it is easy to choose the optimal solution for any need.

Versions:

FCXI AS: with tall cabinet

FCXI U: with universal cabinet for floor/ ceiling installation

FCXI ACT: vertical free standing with electronic thermostat

• Fan unit with Brushless motor (continuous 0-100% speed variation)

• Full compliance with the accident prevention standards

• Rounded line

• Metallic protective cabinet with rustproofing polyester paint

• Adjustable air distribution grille, for U versions

• Fan coil automatic power-off function with closure of the air delivery grille, for U versions

• Quiet operation

• Low loss of charge in the heat exchange batteries

• Ease of installation and maintenance

• Air filter easy to remove and clean

• Extractable shrouds for easy, effective cleaning

• Water connections can be reversed during installation phase

Accessories

WMT21: Control panel with electronic thermostat and LCD monitor. Wall mounting.

PTI2: Control panel with electronic thermostat on the fan coil installation.

VMF System: the characteristics are described on the appropriate card.

AMP: Kit for ceiling installation, for versions

FCXI U.

BC: Auxiliary condensate drip tray.

BV: 1-row hot water coil.

The accessory is not available for the 4R models.

DSC4: Condensate drainage device for use when natural run-off is not possible.

MA: A-type covering cabinet (use tray accessory

BC 4 for FCXI AS, ACT).

MU: U-type covering cabinet (use tray accessory

BC 5-6 for FCXI U).

PC: Sheet metal panel to close rear of unit.

SE: External air damper with command, FCXI AS and ACT.

SWAI: Water temperature probe for WMT21 control panels. Cable length L = 2m.

VMF-SW1: Additional water sensor may be used for 4-pipe system with VMF-E1 and E18 thermostats for the maximum control in the cold range

VCF: Kit comprising motorized 3 way valve with isolating shell, unions and insulated copper pipes.

For 3/4-row and 1-row coils (BV). Versions with

230V and 24V~50Hz power supply.

VCFD: Kit consisting of powered 2-way valve, copper couplings and pipes. For 3/4-row and

1-row coils (BV).

VCF_X4: The valve kits are designed for fan coil units with single coil, installed in a 4 pipe system with the "Cooling" and "Heating" circuits totally separated. The kit consists of 2 valves of 3-way 4 port connection complete with electro-thermal actuators, insulating shells for the valves and associated hydraulic piping. VCF1X4L Valve kit for left hand connection fan coil units. VCF1X4R Valve kit for right hand connection fan coil units. Power supply: 230V ~ 50Hz.

ZX: Feet for floor installations for FCXI AS and ACT models.

16

Accessories

WMT21

SWAI

VMF-SW1

PTI2

VMF-E18

VMF-E2

VMF-E2D

VMF-E4 / E4D

VMF-E5N / B

AMP

AMP20

BC

BV

4

5

6

122

132

142

162

DSC4

PC

SE

33

42

43

62

22

23

32

20X

30X

40X

80X

1X4L o R

2X4L o R

3X4L o R

VCF

VCFD

ZX

5

6

41 - 4124

42 - 4224

43 - 4324

44 - 4424

45 - 4524

1 - 124

2 - 224

3 - 324

4 - 424

(1)(2)

(3)

(3)

(3)

(3)(4)

(3)(4)

(3)(4)

(3)(4)(5) •

(3)(4)

(3)

(3)

(3)

(3)(5)

20

24

30

34

36

FCXI

40

44

50

(1)The DSC4 is not compatible with BC4_5_6_8_9 AMP and accessories. The DSC4 accessory is compatible with AMP20 accessory.

(2) The DSC4 and the VMF-system can not be installed simultaneously on the same fancoil

(3) The BC4 accessory is not available for models fitted with VCF / VCFD valve.

(4) VCF4124-4224-4324-4424-4524 / VCFD124-224-324-424 are 24V

(5) Only for accessory coil BV 1R.

54

56

80

84

AS - U

AS - U

AS - U

AS - e 80U-84U

AS - U

AS - U

U

AS - U

AS - U

U

U

AS - ACT

U

U

AS - U - ACT

AS - U - ACT

AS - U - ACT

AS - U - ACT

AS - U - ACT

AS - ACT

U

AS - ACT

U

AS - ACT

U

AS - U - ACT

AS - ACT

AS - ACT

AS - ACT

AS - ACT

AS - U - ACT

AS - U - ACT

AS - U - ACT

AS - U - ACT

AS - U - ACT

AS - U - ACT

AS - U - ACT

AS - U - ACT

AS - U - ACT

AS - U - ACT

AS - U - ACT

AS - U - ACT

AS - ACT

AS - ACT

17

Technical data

Mod.

Sensible cooling capacity

Water flow rate

Pressure drop

Air flow rate

Fans

Absorbed power

Max. input current

Sound power level

Sound pressure level

(4)

(4)

(4)

(4)

(4)

(4)

(4)

(4)

(4)

(4)

(5)

(5)

(5)

(6)

(6)

(6)

FCXI

W

W

W

W l/h l/h l/h kPa kPa kPa m 3 /h m 3 /h m 3 /h type n°

W

W

W

(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)

Vel.

L

H

M

L

H

M

L

H

M

L

H

M

L

H

M

L

H

M

L

H

M

L

20 24 30 34 36 40 44 50 54 56 80 84

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

Heating capacity (70°C)

Water flow rate

Pressure drop

Heating capacity (50°C)

Water flow rate

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

W

W

W l/h l/h l/h kPa kPa kPa

W

W

W l/h l/h l/h kPa

H

M

L

H

M

L

H

M

L

H

M

L

H

M

L

H

2960 3912 5354 5964 6413 6618 8600 8191 10100 9648 15140 17100

2531 3103 4065 4801 4983 5521 6930 7529 8759 8434 13349 14421

1906 2097 3165 3728 4188 4062 5200 5021 6241 6056 10771 11198

260 343 470 523 563 581 754 718 886 846 1328 1500

222 272 357 421 437 484 608 660 768 740 1171 1295

167

6

4

3

184

4

3

1

278

20

12

8

327

11

7

5

367

13

10

8

356

15

11

6

456

22

15

9

440

15

13

6

547

23

18

9

531

42

33

19

945

21

16

11

982

32

23

15

1.770

2.320

3.160

3.550

3.800

3.960

4.950

4.870

6.100

5.380

7.960

10.200

1.510

1.840

2.400

2.860

2.950

3.300

4.140

4.480

5.220

4.840

6.860

8.600

1.130

1.250

2.060

2.220

2.480

2.430

3.170

3.000

3.700

3.680

5.200

6.700

258 298 413 482 482 585 765 721 855 791 1189 1479

210

144

6

236

174

3

316

267

16

392

303

9

370

311

9

478

397

15

617

463

23

604

432

15

743

533

22

662

475

22

860

738

21

1259

992

31

Pressure drop (2)

(2) kPa kPa

M

L

5

2

2

1

10

7

HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)

(3) W H

1.770

2.850

Heating capacity (70°C)

Water flow rate

Pressure drop

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

W

W l/h l/h l/h kPa kPa kPa

M

L

H

M

L

H

M

L

1.510

1.130

155

132

99

6

5

3

-

-

-

-

-

-

-

-

2.450

2.030

250

215

178

16

12

8

7

4

-

-

-

-

-

-

-

-

-

7

6

2.850

2.450

3.410

2.030

2.660

250

215

178

16

12

8

13

8

3.460

303

299

233

21

20

14

15

9

-

-

-

-

-

-

-

-

-

11

6

4.380

3.940

3.220

384

346

282

35

30

21

17

9

-

-

-

-

-

-

-

-

-

20

15

4.380

3.940

6.300

3.220

5.300

384

346

282

35

30

21

12

9

6.410

562

553

465

15

14

11

23

15

-

-

-

-

-

COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)

Total cooling capacity

(4)

(4)

W

W

H

M

1500 1730 2400 2800 2800 3400 4450 4190 4970 4600 6910 8600

1.220

1.370

1.840

2.280

2.150

2.780

3.590

3.510

4.320

3.850

5.000

7.320

-

-

-

-

43

31

42

35

23

1

12

8

5

0,12

50

5,8

5

2,5

290

220

140

840 1010 1550 1760 1810 2310 2690 2510 3100 2760

1240 1380 1900 2130 2200 2760 3300 3000 3540 3500

4290 5770

5680 5780

1.000

1.090

1.570

1.720

1.820

2.110

2.640

2.540

3.060

3.070

3.780

4.870

670 760 1110 1250 1280 1630 1960 1790 2170 2120 2970 2800

258

210

144

298

236

174

413

316

267

482

392

303

482

370

311

585

478

397

765

617

463

721

604

432

855

743

533

791

662

475

1189

860

738

1479

1259

992

3

2

1

290

220

140

1

12

8

5

0,12

51

46

35

43

38

27

28

17

13

450

350

260

2

13

7

4

0,21

48

41

34

40

33

26

13,8

10

6

450

350

260

2

13

7

4

0,21

48

41

36

40

33

28

28

17

12,7

450

350

260

2

13

7

4

0,21

48

41

34

40

33

26

14,3

10

7

600

460

330 centrifugal

2

17

9

6

0,28

51

44

37

43

36

29

40,2

27

16,3

600

460

330

2

17

9

6

0,28

55

50

41

47

42

33

19,3

14

7,6

720

600

400

2

37

20

8

0,35

56

51

42

48

43

34

25,9

21

11,7

720

600

400

2

37

20

8

0,35

56

53

44

48

45

36

38

28

15,1

720

600

400

2

37

20

8

0,35

56

51

42

48

43

34

22

12

9,3

1140

930

700

3

80

40

30

0,49

61

56

51

53

48

43

29,5

22

14,7

1140

930

700

3

80

40

30

0,49

61

57

51

53

49

43

H max. speed; M med. speed; L min. speed

Heating performance

2 pipes system configuration

(1) Room air temperature 20°C b.s.; Inlet water temperare 70°C; ΔT water 10°C

2 pipes system configuration (EUROVENT)

(2) Room air temperature 20°C b.s.; Inlet water temperare 50°C; Water flow rate as in cooling mode

4 pipes system configuration (with additional heat exchanger) (EUROVENT)

(3)Room air temperature 20°C b.s.; Inlet water temperare 70°C; ΔT water 10°C

Cooling performance (EUROVENT)

(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperare 7°C; DT water 5°C

(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2

(6) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m

Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

18

Technical data

Mod.

Water content

Coil connections

Work percentage compared to the configuration signal

Power supply l

FCXI

ø (4R)

ø (3R)

ø (1R)

%

%

%

Vel.

H

M

L

20

1

-

1/2"

1/2"

90

84

44

24

1,11

3/4"

-

-

90

84

44

30

1,5

-

1/2"

1/2"

90

84

48

34

1,5

3/4"

-

-

90

84

48

36

1,48

-

3/4"

1/2"

90

84

48

40

1,9

-

3/4"

1/2"

90

82

52

230V/1/50Hz

44

1,48

3/4"

-

-

90

82

52

50

1,9

-

3/4"

1/2"

90

86

60

54

1,9

3/4"

-

-

90

86

60

56

2,52

-

3/4"

1/2"

90

86

60

80

3,4

-

3/4"

1/2"

90

84

45

84

2,52

3/4"

-

-

90

84

45

Dimensions (mm)

B

C

B

C

B C

A

A

D

ZX (accessoires)

(standard coil and augmented)

FCXI_AS

FCXI_ACT

FCXI_U

Mod FCXI (AS - ACT)

Height with feet

Width

Depth

Height of feet

Weight (without feet)

Mod FCXI (U)

Height

Width

Depth

Weight

FCXI_U 20-30-36-40-50-56

FCXI_U 24-34-44-54

(standard coil)

(augmented coil)

A

B

C mm mm mm

D mm kg

A

B

C mm mm mm kg

20 / 24

563

750

220

105

15

20 / 24

520

750

220

15

30 / 34 / 36

563

980

220

105

20

30 / 34 / 36

520

980

220

20

A

40 / 44

563

1200

220

105

24

40 / 44

520

1200

220

24

FCXI_U 80

FCXI_U 84

50 / 54 / 56

563

1200

220

105

24

50 / 54 / 56

520

1200

220

24

(standard coil)

(augmented coil)

80 / 84

688

1320

220

125

34

80 / 84

590

1320

220

34

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italy

Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577 www.aermec.com

19

DUALJET

Controlled outlet fan coils

Floor installation

Aermec

participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com

White

housing RAL 9002 head and feet RAL 7044

DUALJET: comfort, everywhere

The perception of uneven temperature distribution, especially vertically, is one of the main factors that can drastically reduce occupants' perceived well-being.

The innovative DUALJET fan coil makes the room more comfortable, by directing the air in such a way as to provide uniform temperature distribution throughout the room.

In winter, warm air is directed towards the floor; in the summer, cool air is directed towards the ceiling.

Features

• Controlled outlet fan coils available in 4 sizes:

- Vertical installation:

DUALJET: without control panel but with VMF-

E0 thermostat, ready for installation on the network as a Slave unit or as a single or Master unit if combined with the wired panel accessories VMF-E4 / VMF-E4D or VMF-E2D control panel.

• All units are compatible with the VMF system

When installing a centralized control VMF-E5B /

VMF-E5N or BMS third party will need to contact your

• Switching the front air outlet or from the top, using the selector on the unit.

• Front outlet for heating operation.

• Outlet from the top for cooling operation.

• Versions with 3-row coil

(sizes 20, 30, 40, 50)

• 3-speed ventilating unit

• Full compliance with the accident prevention standards

• Rounded line

• Metallic protective cabinet with rustproofing polyester paint

• Plastic feet available as accessory

• Quiet operation

• Low loss of charge in the heat exchange batteries

• Electric motors with permanently inserted condensers

• Ease of installation and maintenance

• Air filter easy to remove and clean

• Extractable shrouds for easy, effective cleaning

• Water connections can be reversed during installation phase

Accessories

Control panel and VMF System: The features are described in the dedicated cards.

* VMF-E1D Please contact us.

ZX: Feet for floor mounting

VCF: the kit contains a motorised 3-way valve with insulating shell, plus coupling and pipes in insulated copper. For 4-row, 3-row and

1-row coils (BV). Versions with 230V and

24V~50Hz power supply.

VCFD: Kit consisting of powered 2-way valve, copper couplings and pipes. For 4-row, 3-row and 1-row coils (BV). Versions with 230V and

24V~50Hz power supply.

• VCF_X4: The valve kits are designed for fan coil units with single coil, installed in a 4 pipe system with the "Cooling" and "Heating" circuits totally separated. The kit consists of 2 valves of

3-way 4 port connection complete with electrothermal actuators, insulating shells for the valves and associated hydraulic piping.

VCF1X4L Valve kit for left hand connection fan coil units. VCF1X4R Valve kit for right hand connection fan coil units. Power supply: 230V ~

50Hz.

DUALJET

VMF-E4 • VMF-E4D

VMF-E2D

ZX5

VCF41 • VCF4124

VCF42 • VCF4224

VCFD1 • VCFD124

VCFD2 • VCFD224

VCF1X4L • VCF1X4R

VCF2X4L • VCF2X4R

20

30

40

50

20

Technical data

Mod. DUALJET

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

Heating capacity (70°C)

(1)

(1)

W

W

(1)

(1)

W l/h

Water flow rate

(1)

(1) l/h l/h

Pressure drop

Heating capacity (50°C)

Water flow rate

Pressure drop

(2)

(2)

(2)

(2)

(2)

(2)

(1)

(1)

(1)

(2)

(2)

(2) l/h l/h l/h kPa kPa kPa kPa kPa kPa

W

W

W

cooling PERFORMANCE

Total cooling capacity

Sensible cooling capacity

Water flow rate

Pressure drop

Air flow rate

Fans

Absorbed power

Max. input current

Sound power level

Sound pressure level

Water content

Coil connections

(4)

(4)

(4)

(5)

(5)

(5)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3) kPa kPa m 3 /h m 3 /h m 3 /h type n°

W

W l/h l/h l/h kPa

W

W

W

W

W

W

W

A dB(A) dB(A) dB(A) dB(A) dB(A) l dB(A)

ø

Speed connected

Vel.

M

L

H

M

L

H

H

M

L

H

H

M

L

H

M

L

M

L

M

L

H

M

L

L

H

M

L

H

L

H

H

M

M

H

M

L

H

M

L

H

M

L

H

M

L

20

2960

2531

1906

260

222

167

6

4

3

1770

1510

1130

258

210

144

6

5

2

1500

1220

840

1240

1000

670

258

210

144

5,8

5

2,5

290

220

140

1

25

22

19

0,12

50

43

31

42

35

23

0,79

1/2”

V3

V2

V1

30

5354

4065

3165

470

357

278

20

12

8

3160

2400

2060

413

316

267

16

10

7

2400

1840

1550

1900

1570

1110

413

316

267

28

17

13

450

350

260

0,21

48

41

34

2

44

33

25

40

33

26

1,11

1/2”

V3

V2

V1

Centrifugal

40

9918

5521

4062

581

484

356

15

11

6

3960

3300

2430

585

478

397

15

13

8

3400

2780

2310

2760

2110

1630

585

478

397

14,3

10

7

600

460

330

0,28

51

44

37

2

57

43

30

43

36

29

1,48

3/4”

V3

V2

V1

Power supply

230V/1/50Hz

H max. speed; M med. speed; L min. speed

Heating mode

2 pipes system configuration

(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; DT water 10°C

2 pipes system configuration (EUROVENT)

(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode

Cooling mode (EUROVENT)

(3) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C

(4) Sound power level on the basis of measurements made in compliance with Eurovent 8/2

(5) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m

Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

Dimensions (mm)

C

B

B

C

Mod DUALJET

Height

Height with feet

Widht

Depth

Weight (1)

A mm mm

B mm

C mm

D mm kg

20

520

606

750

220

88

15

(1) Unit in standard configuration without accessories

30

520

606

980

220

88

20

40

520

606

1200

220

88

24

50

520

606

1200

220

88

24

C

B

A

A

C

B

50

4190

3510

2510

3000

2540

1790

721

604

432

19,3

14

7,6

720

600

400

8191

7529

5021

718

660

440

15

13

6

4870

4480

3000

721

604

432

15

11

6

2

67

46

34

0,35

56

51

42

48

43

34

1,48

3/4”

V3

V2

V1

D

D

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italy

Tel. 0442633111 - Telefax 044293577 www.aermec.com

A

A

21

Omnia HL

Fan coils

Universal installations for residential applications

Aermec

participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com

Plasmacluster

(only for Omnia HL PC and PCM)

White colour:

cover: RAL 9002 top and supports: RAL 7044

Grey colour:

cover: FIAT 656 top and supports: RAL 7031

Features

• HL (High Line) fan coils for both horizontal and vertical installation

• 4 sizes and 12 versions:

HL: white body with switch

HL M: metallic grey body with switch

HL N: white body with electronic thermostat VMF

HL NM: metallic grey body with electronic thermostat

VMF

HL L: white cabinet with Self-Closing Louver and electronic thermostat

HL LM: grey cabinet with Self-Closing Louver and electronic thermostat

HL PC: white body with electronic thermostat and Plasmacluster filter (factory-mounted only)

HL PCM: metallic grey body with electronic thermostat and Plasmacluster filter (factorymounted only)

HL S: white body with no on-board controls

VMF System compatible

HL SM: metallic grey body with no on-board controls. VMF System compatible

• 3-speed centrifugal fan

• Very quiet operation

• Aesthetically styled with soft flowing lines

• New adjustable air delivery louver

• Automatic power-off function with closure of the air delivery louver

• Slim dimensions

• Electronic temperature control, automatic fan speed change, automatic season changeover and automatic on - off (with electronic thermostat)

• Water connections reversibility during installation

• Low pressure drop across heat exchanger

• Motors with permanently connected condensers

• Easy installation and maintenance

• Full compliance with safety regulations

Accessories

AMP: Kit for wall/ceiling mounting. Standard on S and SM versions.

BC: Auxiliary condensate drip tray.

BC 10 for vertical installation

BC 20 for horizontal installation

DSC5: Condensate drainage device for use when natural run-off is not possible. DSC5 is not compatible BC10 - BC20 accessories.

PCH - PCHM: Back closing panel, white

(PCHM) or gray (PCHM).

SIT 3-5: Thermostat interface cards. They allow to set up a fancoils network (max. 10) commanded by a centralised panel (switch or thermostat).

SIT3: commands the three speeds of the fan and must be installed on each fancoil of the network; it receives the commands from the switch or from the SIT5 card.

SIT5: commands the 3 fan speeds and up to two valves (four-pipe systems); it sends the thermostat commands to the fancoils network.

SW: Water probe which enables automatic season change-over thanks to the specific electronic thermostats.

SWA: External probe accessory SWA (length

L=6m). It detects the temperature of the room air if connected to the connector (A) of the

FMT21 panel. The room air temperature probe, incorporated in the panel, is automatically disabled. It detects the temperature of the water in the system for ventilation consent if connected to the connector (W) of the FMT21 panel. Two

SWA probes can be connected simultaneously to the FMT21 panel.

VCH: Kit comprising motorized 3-way valve, unions and copper pipes.

VCHD: Kit comprising motorized 2-way valve, unions and copper pipes.

ZH1: White feet for floor-standing installations

ZH1B: White feet for floor-standing installations with skirting board.

ZH1M: Gray feet for floor-standing installations

ZH1MB: Gray feet for floor-standing installations with skirting board.

Control panels

(1) and VMF system (2)

: the characteristics of the control panels are described on the appropriate card.

Compatibility of accessories

Omnia HL

FMT10

(1)

•FMT21

PX2

(1)

PXAE

• PX2C6

(1)

(1)

(1)

TPF

(1)

WMT05

VMF-E4

(2)

• VMF-E4D

VMF-E2H

VMF-E0

(1)

• WMT10

(2)

(2)

• VMF-E1

(1)

(2)

(2)

AMP 10

BC10 *

BC20 *

DSC5 *

PCH/PCHM

SIT3

SIT5

SW3

SWA

VCH

VCHD

ZH1/ZH1B

ZH1M/ZH1MB

11 16 26 36 Versions

• • • • S-SM

• • • • S-SM

• • • • S-SM

• • • • S-SM

• • • • S-SM

• • • • S-SM

• • • • S-SM

• • • • S-SM

• • • • All except S, SM

• • • • All

• • • • All

• • • • All

• • • • All

• • • • S-SM

• • • • S-SM

• • • • S-SM

• • • • S-SM

• • • • All except L, LM

• • • • All except L, LM

• • • • All

• • • • All

PX2C6, PX2 panel in multiple 6-piece pack.

* = The DSC5 accessory is not compatible BC10 - BC20 accessories.

Main features

Versions compatible with VMF System.

Fan cleaning: Omnia fan coils allow fan blades to be easily cleaned. It is now possible to remove the fan volute (it contains the fan blades) and clean it periodically.

Condensate drip tray cleaning: Thanks to a new drip tray fitting, it is now easier to clean it with Omnia fan coils. This important solution avoids, in the long run, bacteria, germs and mould to grow up, in the drip tray because of the air humidity.

Precharged electrostatic filter: Omnia fan coils have, as standard, precharged electrostatic filters. These filters, thanks to their special execution, attracts and retains all suspended dust particles, thus garanteeing pure breathable air to the whole family.

PLASMACLUSTER ionising filter:

Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them. Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions neutralise the gas pollutant molecules, forming products that are normally present in clean air. The result is in the air: you can finally breath clean, odour-free ionised air.

Silent operation: Thanks to the use of special centrifugal fans, Omnia fan coils operation is extremely silent and offers the maximum acoustic comfort.

22

Technical data

Mod.

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

(1) W

Heating capacity (70°C)

(1)

(1)

W

W

Water flow rate

Pressure drop

Heating capacity (50°C)

(1)

(1)

(1)

(1)

(1)

(1)

(2)

(2)

(2)

Water flow rate

(2)

(2) l/h l/h

Pressure drop

(2)

(2)

(2)

(2) l/h kPa kPa kPa

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

(3) W

Total cooling capacity

(3)

(3)

W

W

Sensible cooling capacity

Water flow rate

Pressure drop

Air flow rate

Fans

Absorbed power

Max. input current

Sound power level

Sound pressure level

Water content

Coil connections

(5)

(5)

(5)

(4)

(4)

(4)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3) n°

W

W

W

(A) dB(A) dB(A) dB(A)

W

W

W l/h l/h l/h kPa kPa kPa m

3

/h m

3

/h m

3

/h type dB(A) dB(A) l dB(A)

ø l/h l/h l/h kPa kPa kPa

W

W

W

Speed connected

Vel.

M

L

L

H

H

M

M

L

L

H

H

M

L

H

M

H

M

L

M

L

L

H

H

M

L

H

M

H

M

L

H

M

L

H

M

L

H

M

L

H

M

L

H

M

L

HL 11

1

1150

870

650

144

117

93

2

1

1

2010

1460

1060

176

128

93

2

1

144

117

93

1,9

1

1

180

120

80

840

680

540

700

530

390

0,09

46

37

31

1

18

12

8

37,5

28,5

22,5

0,4

1/2"

V3

V2

V1

HL 16

1

1700

1250

930

206

153

122

4

2

2

2910

2120

1540

255

186

135

4

2

206

153

122

4,8

3

2

240

160

110

1200

890

710

990

710

540

1

32

25

23

0,15

48

43

34

39,5

34,5

25,5

0,5

1/2"

V3

V2

V1

Centrifugal

HL 26

5

2750

2240

1670

349

289

220

10

7

4

4620

3830

2890

405

336

253

11

8

349

289

220

11

9

5

350

270

190

2030

1680

1280

1640

1330

990

0,18

48

43

35

2

35

27

24

39,5

34,5

26,5

0,8

1/2"

V3

V2

V1

Power supply

230V/1/50Hz

H max. speed; M med. speed; L min. speed

Heating mode

2 pipes system configuration

(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; DT water 10°C

2 pipes system configuration (EUROVENT)

(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode

Cooling mode (EUROVENT)

(3) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C

(4) Sound power level on the basis of measurements made in compliance with Eurovent 8/2

(5) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m

Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

HL 36

487

394

286

18,9

12

7

460

350

240

2830

2290

1660

2040

1620

1160

2

42

35

30

0,22

50

43

34

39,5

32,5

25,5

1,1

1/2"

V3

V2

V1

3

3540

2860

2080

487

394

286

16

11

6

5940

4870

3530

521

427

310

7,7

5,4

Dimensions (mm)

Mod Omnia

Height

Widht

Depth

Height with feet

Weight

A

B

C

D kg

HL 11

600

640

187

93

13,6

HL 16

605

750

189

93

14,6

HL 26

615

980

191

93

17,6

HL 36

623

1200

198

93

20,6

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italy

Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577 www.aermec.com

23

Omnia UL

Fan coils

Universal installations for residential applications

Aermec

participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com

Plasmacluster

(only for Omnia UL PC)

White colour:

cover: RAL 9002 top and supports: RAL 7044

Features

• UL (Universal Line) fan coils for both horizontal and vertical installation

Versions:

UL-S: version without switch, with cabinet.

Compatible with VMF System

UL: version with switch and cabinet

UL-C: version with electronic thermostat and with cabinet

UL-PC: version with electronic thermostat and Plasmacluster filter (factory-mounted only) and cabinet

Versions compatible with VMF System.

Fan cleaning: Omnia fan coils allow fan blades to be easily cleaned. It is now possible to remove the fan volute (it contains the fan blades) and clean it periodically.

Condensate drip tray cleaning: Thanks to a new drip tray fitting, it is now easier to clean it with Omnia fan coils. This important solution avoids, in the long run, bacteria, germs and mould to grow up, in the drip tray because of the air humidity.

Precharged electrostatic filter: Omnia fan coils have, as standard, precharged electrostatic filters. These filters, thanks to their special execution, attracts and retains all suspended dust particles, thus garanteeing pure breathable air to the whole family.

PLASMACLUSTER ionising filter:

Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them. Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions neutralise the gas pollutant molecules, forming products that are normally present in clean air. The result is in the air: you can finally breath clean, odour-free ionised air.

Silent operation: Thanks to the use of special centrifugal fans, Omnia fan coils operation is extremely silent and offers the maximum acoustic comfort.

• 3-speed centrifugal fan

• Very quiet operation

• Aesthetically styled with soft flowing lines

• Adjustable air delivery louver

• Automatic power-off function with closure of the air delivery louver

• Slim dimensions

• Electronic temperature control, automatic fan speed change, automatic season changeover and automatic on - off (with electronic thermostat)

• Water connections reversibility during installation

• Low pressure drop across heat exchanger

• Motors with permanently connected condensers

• Easy installation and maintenance

• Air filter easy to remove and to clean

• Full compliance with safety regulations

Accessories

AMP: Kit for wall/ceiling mounting. Standard on P and S versions.

BC: Auxiliary condensate drip tray.

BC 10 for vertical installation

BC 20 for horizontal installation

DSC5: Condensate drainage device for use when natural run-off is not possible. DSC5 is not compatible BC10 - BC20 accessories.

GU: Aspiration grille, covers the front space between the stands, does not interfere with the air filter. Use with ZU stands compulsory.

PCU: Rear cover panel.

SIT 3-5: Thermostat interface cards. They allow to set up a fancoils network (max. 10) commanded by a centralised panel (switch or thermostat).

SIT3: commands the three speeds of the fan and must be installed on each fancoil of the network; it receives the commands from the switch or from the SIT5 card.

SIT5: commands the 3 fan speeds and up to two valves (four-pipe systems); it sends the thermostat commands to the fancoils network.

SW: Water probe wich enables automatic season change-over thanks to the specific electronic thermostats.

SWA: External probe accessory SWA (length L

= 6m). It detects the temperature of the room air if connected to the connector (A) of the

FMT21 panel. The room air temperature probe, incorporated in the panel, is automatically disabled. It detects the temperature of the water in the system for ventilation consent if connected to the connector (W) of the

FMT21 panel. Two SWA probes can be connected simultaneously to the FMT21 panel.

VCH: Kit comprising motorized 3-way valve, unions and copper pipes.

VCHD: Kit comprising motorized 2-way valve, unions and copper pipes.

ZU: Feet for floor-standing solutions.

Control panels and VMF System: The control panels are described in a separate document.

24

Omnia UL_S_C_PC

FMT21

PX2 o PX2C6

PXAE

PXLM

TPF

WMT05

WMT10

VMF-E4 o E4D

VMF-E0 o E1

AMP10

BC10

BC20

DSC5

SIT3

SIT5

SW3

SWA

VCH

VCHD

ZU

(1)

(2)

S

S

S

S

vers.

S

S

S

S

S

UL-C-PC all all all

S

S all

S all all

UL-S-C-PC

11

16

26

36

(1) PX2C6, PX2 panel in multiple 6-piece pack.

(2) The DSC5 accessory is not compatible BC10 - BC20 accessories.

Technical data

Mod.

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

(1) W

Heating capacity (70°C)

(1)

(1)

W

W

Water flow rate

Pressure drop

Heating capacity (50°C)

Water flow rate

Pressure drop

(1)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(1)

(1)

(1)

(1)

(1) kPa

W

W

W l/h l/h l/h kPa kPa kPa l/h l/h l/h kPa kPa

COOLING PERFORMANCE

Total cooling capacity

Sensible cooling capacity

Water flow rate

Pressure drop

Air flow rate

Fans

Absorbed power

Max. input current

Sound power level

Sound pressure level

Water content

Coil connections

(5)

(5)

(5)

(4)

(4)

(4)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3) n°

W

W

W

(A) dB(A) dB(A) dB(A) dB(A) dB(A) l dB(A) l/h l/h l/h kPa kPa kPa m

3

/h m

3

/h m

3

/h type

W

W

W

W

W

W

ø

Speed connected

Vel.

M

L

L

H

H

M

M

L

L

H

H

M

L

H

M

H

M

L

M

L

L

H

H

M

L

H

M

H

M

L

H

M

L

H

M

L

H

M

L

H

M

L

H

M

L

UL11

1

1150

870

650

144

117

93

2

1

1

2010

1460

1060

176

128

93

2

1

144

117

93

1,9

1

1

180

120

80

840

680

540

700

530

390

0,09

46

37

31

1

18

12

8

37,5

28,5

22,5

0,4

1/2"

V3

V2

V1

UL16

1

1700

1250

930

206

153

122

4

2

2

2910

2120

1540

255

186

135

4

2

206

153

122

4,8

3

2

240

160

110

1200

890

710

990

710

540

1

32

25

23

0,15

48

43

34

39,5

34,5

25,5

0,5

1/2"

V3

V2

V1

Centrifugal

UL26

5

2750

2240

1670

349

289

220

10

7

4

4620

3830

2890

405

336

253

11

8

349

289

220

11

9

5

350

270

190

2030

1680

1280

1640

1330

990

0,18

48

43

35

2

35

27

24

39,5

34,5

26,5

0,8

1/2"

V3

V2

V1

Power supply

230V/1/50Hz

H max. speed; M med. speed; L min. speed

Heating mode

2 pipes system configuration

(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; DT water 10°C

2 pipes system configuration (EUROVENT)

(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode

Cooling mode (EUROVENT)

(3) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C

(4) Sound power level on the basis of measurements made in compliance with Eurovent 8/2

(5) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m

Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

UL36

487

394

286

18,9

12

7

460

350

240

2830

2290

1660

2040

1620

1160

2

42

35

30

0,22

50

43

34

39,5

32,5

25,5

1,1

1/2"

V3

V2

V1

3

3540

2860

2080

487

394

286

16

11

6

5940

4870

3530

521

427

310

7,7

5,4

Dimensions (mm)

B

Mod Omnia

Height

Widht

Depth

Height with feet

Weight

A

B

C

D kg

UL 11 UL 16 UL 26 UL 36

513 513 513 513

640 750 980 1200

173

93

12,5

173

93

13,5

173

93

16,5

173

93

19,5

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

A

Wall installation

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italy

Tel. 0442633111 - Telefax 044293730 www.aermec.com

C

A

D

B

Floor installation

ZU

C

25

Omnia Radiant

Fan coils with radiant panel for residential use

Ceiling or floor mounted

Aermec

participate in the EUROVENT program: FCU the products are present on the site www.eurovent-certification.com

• LOW TEMPERATURE RADIATION*

• VENTILATED HEATING

• COOLING - DEHUMIDIFICATION

• ENERGY SAVING

• LOW OPERATING COST

* Radiant technology under licence

Features

Omnia Radiant and Omnia Radiant Plus

Aermec innovative solutions

In this particular worldwide market evolution, we are pleased to present to you OMNIA

Radiant, which represents the innovation of the

OMNIA AERMEC series, fan coils especially designed for residential comfort.

The four different working modes of Omnia

Radiant annual functioning

Radiant: Heating through radiation, comfortable and noiseless, is granted by the radiant plate placed on the front of the fan coil cover; if necessary, the triple-fins delivery head can be closed to increases the heating of the plate, thus maximizing the radiant effect.

OMNIA Radiant inherits all the advantages of the OMNIA UL series, and is characterized by the introduction of the frontal plate for radiant heating.

OMNIA Radiant Plus is provided with the DC

Brushless electric engine, equipped with the latest Inverter technology, granting the highest energy efficiency and able to regulate the air flow through the continuous fan speed modulation. This allows to achieve up to 60% in energy saving when compared to the traditional On-Off fan system, in both air conditioning and heating.

Radiant + Natural Convection

With the triple-fins open, heating through natural convection, obtained thanks to the bigger coil exchange surface, is added to the radiant heating.

As for the radiant-only mode (see above), the fan groups are in off mode. This results in acoustic comfort and energy saving.

OMNIA Radiant and Radiant Plus offer the following advantages when compared to the traditional systems:

• the radiant plate combination – the finned coil allows the best winter comfort with the lower energy consumption because it provides heating with lower water temperature: only 45°C against the about 65°C needed for the traditional radiator. This not only increases the comfort for the user, but also significantly increases the overall efficiency in case of heat pumps usage;

• the fan system allows to quickly reach the desired temperature, meeting the requirement of a fast start-up;

• the unit can be combined other than the boiler, also to energy saving heat pumps: air to water, water to water and geothermic type;

• the electrostatic charge filter standard supplied, provides pure and clean air;

• during summer Omnia Radiant and Radiant

Plus provide air conditioning and dehumidification in a fast and efficient way in every room.

26

Radiant + Forced Convection

The electronic regulation, precise and reliable, continuously compares the effective indoor temperature with the desired temperature: whenever the difference between the two should prove to be too high (e.g. during the heating system startup) the software will lead the fan system start-up.

Start-up is fast and efficient and grants significant energy savings especially in rooms that are occasionally used.

Omnia Radiant during summer provides air conditioning and dehumidification:

Forced Convection

During summer, Omnia Radiant and Radiant

Plus provide air conditioning and dehumidification for each room of the house in a fast and efficient way. Efficiency and quietness benefit from the quality that has always characterized the

Omnia series.

Radiant

Radiant + Natural Convection

Radiant + Forced Convection

Forced Convection

Features of the Omnia Radiant series

1

2

3

4

Radiant plate

Switching valve

Water probe

Condensate storage container, hydraulic hoses

2

3

1

4

VCHRAD accessory

OMNIA radiant (UL_R) standard features:

- Radiant panel

- Centrifugal fans

- Three-speed motor

- Condensate storage container, hydraulic hoses

- Switching valve

- Water probe

- Electro-statically preloaded filter

- VMF-thermostat for asynchronous motor

- Compatible with VMF system

OMNIA radiant plus (UL_RI) standard fea-

tures:

- Radiant panel

- Centrifugal fans

- Electric DC Brushless motor with Inverter

- Condensate storage container, hydraulic hoses

- Water probe

- Switching valve

- Electro-statically preloaded filter

- VMF thermostat for DC Brushless motor

- Compatible with VMF system

Accessories

PCU: Rear closing panel.

ZU: Wedges for floor mount.

GU: Exhaust grille: covers the front space of the wedges and does not interfere with the air filter.

VCHRAD: Kit comprising motorized 3-way valve, unions and copper pipes.

Must be combined with ZU wedges.

VMF System:

Its specs are described in its technical sheet.

Cleaning the fan: The fan blades on the

Omnia Radiant are easy to clean. As a matter of fact, the new versions now offer the possibility of opening the worm screw of the fan (the casing that encloses the blades) to perform routine cleaning.

Electro-statically preloaded filter: The

Omnia Radiant fan coils feature standard air filters that are electro-statically preloaded. These filters, thanks to their particular construction, absorb and trap floating dust: the ideal system to provide clean air for all the family.

Silent operation: Thanks to special centrifugal fans, Omnia Radiant fan coils are incredibly silent, making them the best buy when it comes to acoustic comfort, given the total lack of peak noise. "The heating by radiation

at top speed ensures total silence regime”

Note:

The coil had hydraulic hoses on the left and is not reversible.

PCU

GU

VCHRAD

ZU

VMF system

VMF-E4 (compulsory accessory)

VMF-E4D (compulsory accessory)

VMF-E5B

VMF-E5N

* Contact us

Omnia radiant

UL26R UL36R

25 35

25

35

*

*

*

*

Omnia Radiant plus

UL26RI UL36RI

25 35

25

35

27

Technical Data

Mod. UL_R

Heating capacity (70°C)

Heating capacity (50°C)

Water flow rate

Water pressure drop

Static heating power (70°C)

Static heating power (50°C)

Static heating power (35°C)

Total cooling capacity

Sensible cooling capacity

Water flow rate

Water pressure drop

Air flow rate n° Fans

Sound pressure

Sound power

Water contents

Max. motor power

Max. input current

Coil connections (in/out)

Power supply

(1)

W (max.)

W (med.)

W (min.)

(2) W l/h kPa

(3) W

(4) W

(5) W

W (max.)

W (med.)

W (min.)

W (max.)

W (med.)

W (min.) l/h kPa m 3 /h (max.) m 3 /h (med.) m 3 /h (min.) n.

dB (A) (max.) dB (A) (med.) dB (A) (min.) dB (A) (max.) dB (A) (med.) dB (A) (min.) l

W

A

ø (mm)

V/ph/Hz

Mod. UL_RI

Heating capacity (70°C)

Heating capacity (50°C)

Water flow rate

Water pressure drop

Static heating power (70°C)

Static heating power (50°C)

Static heating power (35°C)

Total cooling capacity

Sensible cooling capacity

Water flow rate

Water pressure drop

Air flow rate n° Fans

Sound pressure

Sound power

Water contents

Max. motor power

Max. input current

Coil connections (in/out)

Power supply

(1)

(2)

(3)

(4)

(5)

W (max.)

W (med.)

W (min.)

W l/h kPa

W

W

W

W (max.)

W (med.)

W (min.)

W (max.)

W (med.)

W (min.) l/h kPa m 3 /h (max.) m 3 /h (med.) m 3 /h (min.) n.

dB (A) (max.) dB (A) (med.) dB (A) (min.) dB (A) (max.) dB (A) (med.) dB (A) (min.) l

W

A

ø (mm)

V/ph/Hz

Cooling:

Room temperature 27°C b.s./19°C b.u.; Cold water (in/out) 7°C/12°C

Heating:

(1) Room temperature 20°C b.s.; Hot water (in) 70°C; ΔT 10°C

(2) Room temperature 20°C b.s.; Hot water (in/*) 50°C/*°C (water flow same as in heating cycle)

(3) Radiant power + natural convection; Hot water (in) 70°C (water flow same as in heating cycle)

(4) Radiant power + natural convection; Hot water (in/*) 50°C/*°C (water flow same as in heating cycle)

(5) Radiant power + natural convection; Hot water (in/*) 35°C/*°C (water flow same as in heating cycle)

18

350

270

190

2

39,5

34,5

26,5

48

200

2030

1780

1420

1640

1370

1050

349

26

4620

3830

2890

2750

397

17

650

390

43

35

0,8

12

0,18

14

230V/1/50Hz

26

4620

3830

2890

2750

397

17

650

390

200

270

190

2

39,5

34,5

26,5

48

43

35

2030

1780

1420

1640

1370

1050

349

18

350

0,8

35

0,18

14

230V/1/50Hz

22

460

350

240

2

39,5

32,5

25,5

50

230

2830

2310

1730

2040

1790

1280

487

36

5940

4870

3530

3540

511

21

750

450

41

34

1,1

16

0,22

14

230V/1/50Hz

36

5940

4870

3530

3540

511

21

750

450

230

350

240

2

39,5

32,5

25,5

50

41

34

2830

2310

1730

2040

1790

1280

487

22

460

1,1

42

0,22

14

230V/1/50Hz

Level of sound pressure (A-weighted) measured in the room with volume V = 85m3 ; reverberation time t = 0.5s; direction factor Q = 2; distance r = 2.5m

28

Heating capacity with fan off

UL26R - UL26RI

600

500

400

300

200

100

0

35 40 45 50 55 60 65

Inlet water temperature [°C]

70

UL36R - UL36RI

900

800

700

600

500

400

300

200

100

0

30

16°C

20°C

22°C

26°C

35 40 45 50 55 60 65 70 75

Inlet water temperature [°C]

80

20°C

26°C

Dimensions (mm)

C

B

A

Wall installation

C

B

A

ZU

Mod OMNIA ULR - ULRI

Height

Width

Depth

Height with ZU (Accessories)

Weight (1)

A

B

C

D

(1) Standard configuration of unit with accessories

(mm)

(mm)

(mm)

(mm)

(kg)

26

606

980

173

93

20

D

Floor installation

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italia

Tel. 0442633111 - Telefax 044293577 www.aermec.com

36

606

1200

173

93

24

29

FCX P

Fan coils

Duct installation

Aermec

participate in the EUROVENT program: FCU the products are present on the site www.eurovent-certification.com

Features

Vertical and horizontal installation:

FCX P: Duct installation without cabinet

FCX PPC: Duct installation without cabinet, with

Plasmacluster purifier. Compatible with the VMF system, or you can request a combination with the

PXAE control panel

FCX PE: Duct installation without cabinet and with direct expansion coil

FCX PO: with boosted motor

6-speed (3 of which can be selected) up 22 to 82

7-speed (3 of which can be selected) up 62 to 82

FCX PBV: with 3 row coil +1 in a single shoulder, standard connections (left)

FCX PBVD: with 3 row coil +1 in a single shoulder, standard connections (right)

FCX POBV: boosted and with 3 row coil +1 in a single shoulder, standard connections (left)

FCX POBVD: boosted and with 3 row coil +1 in a single shoulder, standard connections (right)

For versions with 3 row +1 battery, the battery is not reversible specify the side of the attacks

at the time of the order.

- Vertical installation:

FCX PV: Duct installation without cabinet

• Versions with 3/4-row coil

• 3-speed ventilating unit

• Compatible with the VMF system

• Wide range of controls and accessories

• Quiet operation

• Low loss of charge in batteries

• Electric motors with permanently inserted condensers

• Ease of installation and maintenance

• Air filter easy to remove and clean

• Possibility of a residual head for ducting (if required)

• Internal insulation and air filter in fire resistance class 1

• Extractable shrouds for easy, effective cleaning

• Water connections can be reversed during installation phase

VERSION

FCX_P

FCX_PV

FCX_PO

FCX_PE

FCX_PPC

FCX_PBV

FCX_PBVD

FCX_POBV

FCX_POBVD

Accessories

17

-

-

17

17

-

-

17

-

22

22

22

22

22

22

22

22

22

32

32

32

32

32

32

32

32

32

Versions with 3 row coil

36 42 50 56

36

36

36

36

36

36

-

36

42

42

42

42

42

42

42

42

50

50

50

50

50

50

50

50

56

56

56

56

56

56

-

56

AVAILABLE SIZES

62

62

62

62

62

62

62

62

62

82

82

82

82

82

82

82

82

82

102

102

-

102

-

102

102

-

-

24

-

-

-

-

24

24

-

24

34

Versions with 4 row coil

44 54 64

-

-

-

-

34

34

-

34

-

-

-

-

44

44

-

44

-

-

-

-

54

54

-

54

-

-

-

-

64

64

-

64

84

-

-

-

-

84

84

-

84

AMP: Kit for overhang installation.

BC: Auxiliary condensate drip tray.

BV: 1-row hot water coil. Not available for

4-row versions or those with Plasmacluster.

When mounted in place, you must specify the con-

nection side

CHF:VentilCassaforma is a galvanised metal template that allows you to create a space directly in the wall for housing the fan coil. (For

FCX P - PV only).

DSC4: Condensate drainage device for use when natural run-off is not possible.

GA: Intake grille with fixed fins.

GAF: Intake grille with fixed fins and filter.

GM: Delivery grille with adjustable fins.

MA: A-type covering cabinet (use tray accessory BC 4 for FCX AS).

MU: U-type covering cabinet (use the BC 5-6 tray accessory if horizontal, or BC 4 if vertical).

PCR: Galvanised plate protection for the controls and the electrical element.

PA: Plenum suction assembly in galvanised sheet metal, complete with suction couplings for circular-section ducts.

PA-F: Plenum suction assembly that allows intake and delivery on the same side; suitable for all installations where the machine needs to be positioned outside the air-conditioned rooms in order to minimise noise levels and facilitate maintenance operations.

PM: Delivery plenum in galvanised sheet metal, externally insulated, complete with plastic delivery couplings for circular section ducts.

RD: Straight delivery coupling for canalisation.

RDA: Straight suction coupling for canalisation.

RP: 90° delivery coupling for canalisation.

RPA: 90° suction coupling for canalisation.

RX: Armoured electric coil with safety thermostat. (Requires a thermostat with heater management). Not available for 4-row versions or those with Plasmacluster.

SE: Manually operated fresh air intake louver.

SIT 3 - 5: Thermostat Interface Cards. They allow the creation of a network of fan coils

(max. 10) commanded by a central control panel (selector or thermostat).

SIT3: commands the 3 fan speeds and must be installed on each fan coil of the network; receives the commands from the selector or the SIT5 card.

SIT5: commands the 3 fan speeds and up to 2 valves (four pipes systems); sends the commands of the thermostat to the fan coils network.

SW: water temperature probe that gives the automatic season change feature to electronic thermostats supplied with water-side change over.

SWA: External probe accessory SWA (length L = 6m). It detects the temperature of air or water depending on its location in the plant

VCF: the kit contains a motorised 3-way valve with insulating shell, plus coupling and pipes in insulated copper. For 4-row, 3-row and

1-row coils (BV). Versions with 230V and

24V~50Hz power supply

VCFD: Kit consisting of powered 2-way valve, copper couplings and pipes. For 4-row, 3-row and 1-row coils (BV). Versions with 230V and

24V~50Hz power supply.

VCF_X4: The valve kits are designed for fan coil units with single coil, installed in a 4 pipe system with the "Cooling" and "Heating" circuits totally separated. The kit consists of 2 valves of 3-way 4 port connection complete with electro-thermal actuators, insulating shells for the valves and associated hydraulic piping. VCF1X4L Valve kit for left hand connection fan coil units. VCF1X4R Valve kit for right hand connection fan coil units. Power supply: 230V ~ 50Hz.

ZX: Feet for recessed installation.

Control panels and VMF System: the characteristics are described on the appropriate card.

30

Accessories

FMT10 • FMT21

KTLP

PX • PX2 • PX2C6

PXAE

PXAR

TF1

TPF

WMT05 • WMT06 • WMT10

VMF-E4 • VMF-E4D

VMF-E0 • VMF-E1

AMP

AMP20

BC

BV

CHF

142

162

17

22

32

42

62

6

8

4

5

9

117

122

132

DSC4

GA

GAF

GM

MA

MU

PA

PA

PCR

PM

RD

RDA

RP

RPA

RX

42

62

17

22

62

17

22

32

32

42

52

62

17

22

32

42

22

32

42

62

32

42

62

17

42

62

17

22

2

17

22

32

32 F

42 F

62 F

1

62

17

22

32

42

62

17 F

22 F

17

22

32

42

22

32

42

62

32

42

62

17

42

62

17

22

62

17

22

32

17

22

32

42

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(2)

(3)

17

24

22

34

32

36

FCX Fan Coil

42

44

• • •

50

56

54

• • •

• •

• • •

• • • • •

• •

• • •

• • • • •

• •

• • •

• • • • •

• •

• • •

• • • • •

• •

• • •

• • • • •

• •

• • •

• • • • •

• •

• • •

• • • • •

• •

• • •

• • • • •

• •

• • •

• • • • •

• •

• • •

• • • • •

• •

• • •

• • • • •

• •

• • •

• • • • •

• •

• •

64

62

82

84 102 Versions

P-PE-PO-PV

P-PE-PO-PV

P-PE-PO-PV

P-PE-PO-PV-PPC

P-PE-PO-PV

P-PE-PO-PV

P-PE-PO-PV

P-PE-PO-PV

• •

P-PE-PO-PV

P-PE-PO-PV-PPC

P-PE-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PPC

P-PE-PO-PPC

FCX P-PV+ MA

FCX P + MU

FCX P + MU

P-PE-PO-PPC

P-PE-PO-PPC

P-PE-PV

P-PE-PO-PV

P-PE-PO-PV

P-PE-PO-PV

P-PE-PO-PV

P-PV

P-PV

P-PV

P-PV

P-PV

P-PE-PO-PV-PPC

P-PE-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PPC

P-PE-PV

P-PE-PO-PV

P-PE-PO-PV

P-PE-PO-PV

P-PE-PO-PV

P-PE-PO-PV

31

Accessories

SE

SIT

SW3

SWA

VCF

VCFD

ZX

15X

20X

30X

40X

80X

3

5

1X4L - 1X4R

2X4L - 2X4R

3X4L - 3X4R

41 - 4124

42 - 4224

43 - 4324

44 - 4424

45 - 4524

7

8

1 - 124

2 - 224

3 - 324

4 - 424

(4)

(4)

(4)

(4)

(4)

(5)

(5)

(5)

(5)(6)

(5)

(5)

(5)

(5)

(5)(7)

17

22

24

32

34

36

FCX Fan Coil

(1) the characteristics are described on the appropriate card.

(2) Accessories and BC4 VCF can not be mounted at the same time

(3) DSC4 is incompatible with the accessory AMP and BC Auxiliary condensate drip tray

42

44

50

54

56

62

64

(4) The accessory SE require pairing with ZX

(5) 24 Volt

(6)

Only for the BV1-row coil accessory

82

Technical data

84 102 Versions

P-PE-PV

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

P-PE-PO-PV

P-PE-PO-PV-PPC

P-PO-PV

P-PO-PV

P-PO-PV

P-PO-PV

P-PO-PV

P-PO-PV-PPC

P-PO-PV-PPC

P-PO-PV-PPC

P-PO-PV

P-PO-PV

P-PO-PV-PPC

P-PO-PV-PPC

P-PO-PV-PPC

P-PO-PV

P-PE-PO-PV-PPC

P-PE-PO-PV-PPC

Mod. FCX_P / FCX_PO Vel.

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

Heating capacity (70°C)

(1) W

(1) W

H

M

17 22 24 32 34 36 42 44 50 54 56 62 64 82 84 102

2296 2960 3912 5354 5964 6413 6618 8600 8191 10100 9648 12919 14300 15140 17100 17019

2033 2531 3103 4065 4801 4983 5521 6930 7529 8759 8434 10942 11501 13349 14421 15242

Water flow rate

Pressure drop

(1)

(1)

(1)

(1) W

(1) l/h

(1)

(1) l/h l/h kPa kPa kPa

L

H

M

L

H

M

L

1686 1906 2097 3165 3728 4188 4062 5200 5021 6241 6056 8327 8499 10771 11198 12558

201

178

148

3

2

1

260

222

167

6

4

3

343

272

184

4

3

1

470

357

278

20

12

8

523

421

327

11

7

5

563

437

367

13

10

8

581

484

356

15

11

6

754

608

456

22

15

9

718

660

440

15

13

6

886

768

547

23

18

9

846

740

531

42

33

19

1133

960

730

17

12

7

1254

1009

745

23

16

9

1328

1171

945

21

16

11

1500

1295

982

32

23

15

1493

1337

1101

43

34

24

Heating capacity (50°C)

(2) W

(2) W

(2) W

(2) l/h

H

M

L

H

1360

1200

990

172

1770

1510

1130

258

2320

1840

1250

298

3160

2400

2060

413

3550

2860

2220

482

3800

2950

2480

482

3960

3300

2430

585

4950

4140

3170

765

4870

4480

3000

721

6100

5220

3700

855

5380

4840

3680

791

7500

6430

4880

836

8400

6800

5040

1092

7960 10200 10000

6860

5200

1189

8600

6700

1479

9000

7440

1311

Water flow rate (2)

(2)

(2)

(2) l/h l/h kPa kPa

M

L

H

M

144

112

2

2

210

144

6

5

236

174

3

2

316

267

16

10

392

303

9

7

370

311

9

7

478

397

15

13

617

463

23

15

604

432

15

11

743

533

22

17

662

475

22

20

752

554

9

7

896

674

18

13

860 1259 1183

738 992 979

21

12

31

23

33

27

Pressure drop

HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)

Heating capacity (70°C)

Water flow rate

Pressure drop

(2)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3) kPa

W

W

W l/h l/h l/h kPa kPa

L

H

M

L

H

M

L

H

M

1

1400

1200

990

123

105

87

3

2

2

1770

1510

1130

155

132

99

6

5

1

-

-

-

-

-

-

-

-

7

2850

2450

2030

250

215

178

16

12

4

-

-

-

-

-

-

-

-

6

-

-

-

-

-

-

-

-

8

3460

3410

2660

303

299

233

21

20

9

-

-

-

-

-

-

-

-

6

4380

3940

3220

384

346

282

35

30

9

-

-

-

-

-

-

-

-

15

-

-

-

-

-

-

-

-

4

5490

4700

3870

482

412

339

16

12

8

-

-

-

-

-

-

-

-

9

6410

6300

5300

562

553

465

15

14

15

-

-

-

-

-

-

-

-

19

6810

6230

5430

6809

6232

5428

19

16

Total cooling capacity

(3)

COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)

(4) W H 1000 1500 1730 2400 2800 2800 3400 4450 4190 4970 4600 4860 6350 6910 8600 7620

(4) kPa

W

(4) W

L

M

L

2

840

650

3

1220

840

-

1370

1010

8

1840

1550

-

2280

1760

-

2150

1810

14

2780

2310

-

3590

2690

21

3510

2510

-

4320

3100

-

3850

2760

10

4370

3220

-

5210

3920

11

5000

4290

-

7320

5770

13

6880

5690

Sensible cooling capacity

Water flow rate

Pressure drop

Air flow rate

Fans

Absorbed power

(4)

(4)

(4)

(4)

(4)

(4) W

(4) W

(4) W

(4) l/h l/h l/h kPa kPa kPa m

3

/h m

3

/h m

3

/h type n°

W

W

W

H

M

L

H

M

L

H

M

L

H

M

L

H

M

L

830 1240 1380 1900 2130 2200 2760 3300 3000 3540 3500 3980 5030 5680 5780 5530

690 1000 1090 1570 1720 1820 2110 2640 2540 3060 3070 3300 4100 3780 4870 5350

510 670 760 1110 1250 1280 1630 1960 1790 2170 2120 2440 3060 2970 2800 4420

172 258 298 413 482 482 585 765 721 855 791 836 1092 1189 1479 1311

144

112

2,6

2

1,4

200

160

110

1

35

29

19

210

144

5,8

5

2,5

290

220

140

1

25

22

19

236

174

3

2

1

290

220

140

1

33

29

25

316

267

28

17

13

450

350

260

2

44

33

25

392

303

13,8

10

6

450

350

260

2

44

34

28

370

311

28

17

12,7

450

350

260

2

44

33

25

478

397

14,3 40,2 19,3 25,9

10

7

600

460

330

2

57

43

30

617

463

27

16,3

600

460

330

2

57

43

30

604

432

14

7,6

720

600

400 centrifugal

2

67

46

34

743

533

21

11,7 15,1

720

600

400

2

76

52

38

662

475

38

28

720

600

400

2

76

52

38

752

554

17,3

14

8,3

920

720

520

3

82

61

40

896

674

13

9

5,5

860 1259 1183

738

22

12

9,3

992

29,5

22

14,7

979

37,3

31

22

920 1140 1140 1300

720 930 930 1.120

520 700 700 900

3

91

60

38

3

106

80

59

3

106

80

59

3

131

100

80

32

Mod. FCX_P / FCX_PO

Max input current

Sound power level (P)

Sound pressure level (P)

Sound power level (PO)

Sound pressure level (PO)

Water content

Coil connections

Speed connected

(6)

(6)

(5)

(5)

(5)

(6)

(P) (A)

(PO) (A)

(5) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)

(6)

P

P

P l dB(A)

ø (4R)

ø (3R)

ø (1R)

Vel.

M

L

H

H

M

L

H

H

H

M

L

17 22 24 32 34 36 42 44 50 54 56

0,16 0,12 0,25 0,21 0,45 0,21 0,28 0,51 0,35 0,36 0,35

-

45

38

31

37

62

0,4

64 82 84 102

0,48 0,49 0,62 0,58

0,25 0,25 0,45 0,45 0,45 0,51 0,51 0,36 0,36 0,36 0,48 0,48 0,62 0,62

50

43

31

42

51

46

35

43

48

41

34

40

48

41

36

40

48

41

34

40

51

44

37

43

55

50

41

47

56

51

42

48

56

53

44

48

56

51

42

48

57

51

42

49

57

51

44

49

61

56

51

53

61

57

51

53

-

66

61

56

58

30

23

-

35

23

58

38

27

58

33

26

53

33

28

53

33

26

53

36

29

59

42

33

59

43

34

59

45

36

59

43

34

59

43

34

62

43

36

62

48

43

64

49

43

64

53

48

-

50

0,58 0,79

-

1/2" 1/2"

1/2" 1/2"

V3

V2

V1

V3

V2

V1

50

1

3/4"

-

-

V3

V2

V1

44

-

1/2"

1/2"

V3

V2

V1

44

1,11 1,5

3/4"

-

-

V3

V2

V1

44 50 50 51

1,5 1,48 1,9 1,48

-

3/4"

1/2"

V3

V2

V1

-

3/4"

1/2"

V3

V2

V1

3/4"

-

-

V3

V2

V1

-

3/4"

1/2"

V3

V2

V1

230V/1/50Hz

51

1,9

3/4"

-

-

V3

V2

V1

51

-

3/4"

1/2"

V3

V2

V1

54

1,9 2,52

-

3/4"

1/2"

V3

V2

V1

54 56

3,4 2,52

3/4"

-

-

V3

V2

V1

-

3/4"

1/2"

V3

V2

V1

56

3,4 2,52

3/4"

-

-

V3

V2

V1

-

-

3/4"

1/2"

V3

V2

V1

Power supply

H max. speed; M med. speed; L min. speed

Heating mode

2 pipes system configuration

(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C

2 pipes system configuration (EUROVENT)

(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode

4 pipes system configuration (with additional heat exchanger) (EUROVENT)

(3)Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C

Cooling mode (EUROVENT)

(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C

FCX22÷50

Speed

V1 V2 V3 V4 V5 V6

V1 V2 V3 V4 V5 V6 V7

L7 L6 L5 L4 L3 L2 L1

FCX62÷82

(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2

(6) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m

Note: The speed of associates may differ from the standard factory configuration, for more information refer to the program selection and the technical documentation available on the website www.aermec.com

Dimensions (mm)

FCX_P (standard coil/augmented coil)

C

D

A

B

FCX_P 20-30-36-40-50-56

FCX_P 24-34-44-54

B

9x20

(standard coil)

(augmented coil)

Mod FCX_P

Height

Width

Depth

Weight

* Overall dimensions

A

B*

D

C kg

17

453

452

412

216

11

22 /24 32/34/36 42/44 50/54/56 62/64 82/84

453

562

522

453

793

753

453

1013

973

453

1013

973

558

1147

1122

558

1147

1122

216

13

216

18

216

22

216

22

216

33

216

33

F G H

I

L

102

558

1147

1122

216

33

M

E

FCX_P 80

FCX_P 84

9x20

B

(standard coil)

(augmented coil)

F G H

E

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

I

L

M

F

G

I

H

E

L

M

17

330

41

101

74

49

144

260

22/24 32/34/36 42/44 50/54/56 62/64 82/84

440

41

101

74

49

144

260

671

41

101

74

49

144

260

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italia

Tel. 0442633111 - Telefax 044293577 www.aermec.com

891

41

101

74

49

144

260

891

41

101

74

49

144

260

1102

41

107

68

32

253

273

1102

41

107

68

32

253

273

102

1102

41

107

68

32

253

273

33

FCXI P

Fan coils with Brushless Inverter motor (EC)

In-duct installation

Aermec is participating in the EUROVENT Program

: FCH/FCPH

The related products can be found at the website www.eurovent-certification.com

• ELECTRIC SAVING EQUAL TO 50% COMPARED TO A

FAN COIL WITH 3-SPEED MOTOR

• FULLY SILENT FUNCTIONING

• FULL COMFORT: REDUCED TEMPERATURE AND

RELATIVE HUMIDITY OSCILLATIONS

Features

Recessed fan coils with inverter technology, for heating, cooling and dehumidifying, specific to work in sensible environment.

Equipped with inverter Brushless motor for an high effciency and a continuos air flow rate modulation in order to increased comfort and guarantee electric saving. The inverter motor allows a better air temperature regulation on based on the real indoor envirorement requirements without temperature swinging.

The FCXI P are the ideal solution for 2/4-pipe systems and for tertiary and commercial installations.

Versions:

FCXI P: wall/ceiling mounted without cabinet

FCXI PBV: wall/ceiling mounted without cabinet with double circuit coil for 4-pipe system with standard connections (left)

FCXI PBVD: wall/ceiling mounted without cabinet with double circuit coil for 4-pipe system with right connections

The hydraulic connections of the BV and BVD versions, up to size 56, are not reversible during installation. Specify the connection side when

placing the order.

• Brushless motor with 0-100% speed continuous variation to guarantee best performance at very low sound level

• Centrifugal fan designed to guarantee continuous modulation of the air flow rate and to increase comfort and electric saving.

• Unit with standard coil (20 ÷80)

• Unit with larger coil (24

÷84)

• Low pressure drop

• Air filter with easy extraction and cleaning

• Removable augers for easy and effective cleaning

• Reversibility of the hydraulic connections in the installation phase

A specific wall-control range is available for the

FCXI P. Choose between these panels for simple and complete regulation. Refer to the specific sheet for further details.

Accessories

WMT21: Electronic thermostat with LCD display (wall installation).

SWAI: Water temperature probe for WMT21 electronic thermostat.

VMF System: Find the features in the specific sheets.

AMP: Kit for wall/ceiling mounted installation.

BC: Auxiliary condensate drip tray.

BV: Hot water coil with one row. It is not available for versions with 4 rows or with Plasmacluster.

Specify the connection side in case of in-site

assembly.

PMZ: Plenum with motorised dampers (refer to the specific sheet for further details).

CHF: The VentilCassaforma is a galvanised sheet steel template, for P versions, which allows you to obtain a space for housing the fan coil, directly in the wall.

DSC4: Device for draining condensate.

GA: Intake grid with fixed louvers.

GAF: Intake grid with fixed louvers with filter.

GM: Flow grid with adjustable louvers.

MA: Protective cabinet, type A (use BC 4 tray accessory).

MU: Protective cabinet, type U (use BC 5-6 tray accessory if horizontal or use BC 4 if vertical).

PA: Galvanised sheet steel intake plenum equipped with intake fittings for circular section ducts.

PA-F: Intake plenum, which allows recovery and flow on the same side. It is suitable for all those installations outside air-conditioned rooms, in order to minimise noise and facilitate maintenance operations.

PM: Galvanised sheet steel flow plenum, externally insulated, equipped with plastic flow fittings for ducts and circular sections.

RD: Straight flow fitting for ducting.

RDA: Straight intake fitting for ducting.

RP: 90° flow fitting for ducting.

RPA: 90° intake fitting for ducting.

SE: External air damper with manual control.

VCF: Kit made up of 3-way motorised valves with insulating shell, insulated copper fittings and pipes. For 4, 3, and 1-row coils (BV) Versions with

230V and 24V~50Hz power supply.

VCFD: Kit composed of 2-way motorised valve and copper pipes and connections. For 4, 3, and

1-row coils (BV) Versions with 230V and

24V~50Hz power supply.

Control panels and VMF System:

Find the features in the specific sheets.

34

Accessories

FCXI_P

WMT21

SWAI

AMP

AMP20

BC 6

8

4

5

9

122

132

142

162

22

32

42

62

(3)

(3)

(3)

(3)(4)

(3)(4)

(3)(4)

(3)(4)(5)

(3)(4)

(3)

(3)

(3)

(3)(5)

20

24

30

34

36

40

44

50

54

56

80

84

BV

CHF

DSC4

GA

GAF

GM

MA

MU

PA

PA

PM

RD

RDA

RP

RPA

SE

VCF

VCFD

ZX

20X

30X

40X

80X

1X4L - 1X4R

2X4L - 2X4R

3X4L - 3X4R

41 - 4124

7

8

42 - 4224

43 - 4324

44 - 4424

45 - 4524

1 - 124

2 - 224

3 - 324

4 - 424

22

32

42

62

22

32

42

62

22

32

42

62

22

32

42

62

22

32

42

62

22F

32F

42F

62F

22

32

42

62

22

32

42

62

22

32

42

62

22

32

42

62

22

32

42

62

22

32

42

62

(1)(2)

(1) The DSC4 accessory is not compatible with the BC4_5_6_8_9 trays and AMP installation brackets. It is compatible only with AMP20.

(2) DSC4 and the VMF-system accessories cannot be installed simultaneously on the same fan coil

(3) The VCF / VCFD valves and the BC4 tray cannot be installed simultaneously on the same fan coil

(4) VCF4124-4224-4324-4424-4524 / VCFD124-224-324-424 are 24V

(5) For BV coil with 1 row or for PBV/PBVD versions.

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

(P+MA)

(P+MU)

(P+MU)

P

35

Technical data (Eurovent FCH)

Mod. FCXI_P without static pressure Speed

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

(1) W H

Thermal power (70°C) (1)

(1)

(1)

W

W l/h

M

L

H

Water flow rate pressure drops

(1)

(1)

(1)

(1) l/h l/h kPa kPa

M

L

H

M

20

2960

2531

1906

260

222

167

24

3912

3103

2097

343

272

184

30

5354

4065

3165

470

357

278

Thermal power (50°C)

(1)

(2)

(2)

(2)

(2) kPa

W

W

W l/h

L

H

M

L

H

6

4

3

1,770

1,510

1,130

258

4

3

1

2,320

1,840

1,250

298

20

12

8

3,160

2,400

2,060

413

Water flow rate (2)

(2)

(2)

(2) l/h l/h kPa kPa

M

L

H

M

210

144

6

5

236

174

3

2

316

267

16

10 pressure drops

(2) kPa L 2 1 7

HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)

Thermal power (70°C)

(3)

(3)

W

W

H

M

1,770

1,510

-

-

2,850

2,450

Water flow rate

Pressure drops

(3)

(3)

(3)

(3)

(3)

(3)

(3)

W l/h l/h l/h kPa kPa kPa

M

L

L

H

L

H

M

1,130

155

132

5

3

99

6

-

-

-

-

-

-

-

2,030

250

215

178

16

12

8

COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)

(4) W H 1500

Total cooling capacity (4)

(4)

W

W

M

L

1,220

840

Sensitive cooling capacity

(4)

(4)

(4)

(4)

W

W

W l/h

H

M

L

H

1240

1,000

670

258

Water flow rate

Water pressure drops

Air flow rate

(4)

(4)

(4)

(4)

(4) l/h l/h kPa kPa kPa m3/h m3/h

M

L

H

M

L

H

M

L

Centrifugal

Input power

Maximum input current

Sound power level

Sound pressure level

Water content

Coil connections

Work percentage compared to the configuration signal

(5)

(5)

(5)

(6)

(6)

(6) m3/h type n°

W

W

W

(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)

%

%

% l

ø (4R)

ø (3R)

ø (1R)

H

M

L

H

M

L

H

M

L

H

M

L

8

5

1

12

0.12

50

43

210

144

5.8

5

2.5

290

220

140

0.79

-

1/2"

1/2"

90

84

44

31

42

35

23

Electric power supply

1730

1,370

1010

1380

1,090

760

298

236

174

3

2

1

290

220

140

1

12

8

5

0.12

51

46

35

43

38

27

1

3/4"

-

-

90

84

44

2400

1,840

1550

1900

1,570

1110

413

316

267

28

17

13

450

350

260

1.11

-

1/2"

1/2"

90

84

48

34

40

33

26

7

4

2

13

0.21

48

41

34

5964

4801

3728

523

421

327

11

7

5

3,550

2,860

2,220

482

392

303

9

7

4

-

-

-

-

-

-

-

-

-

2800

2,280

1760

2130

1,720

1250

482

392

303

13.8

10

6

450

350

260

2

13

7

4

0.21

48

41

36

40

33

28

1.5

3/4"

-

-

90

84

48

36

6413

4983

4188

563

437

367

13

10

8

3,800

2,950

2,480

482

370

311

9

7

6

-

-

-

-

-

-

-

-

-

2800

2,150

1810

2200

1,820

1280

482

370

311

28

17

12.7

450

350

260

2

13

7

4

0.21

48

41

34

40

33

26

1.5

-

3/4"

1/2"

90

84

48

40

6618

5521

4062

581

484

356

15

11

6

3,960

3,300

2,430

585

478

397

15

13

8

3,460

3,410

2,660

303

299

233

21

20

14

3400

2,780

2310

2760

2,110

1630

585

478

397

14.3

10

7

600

460

330 centrifugal

2

17

9

6

0.28

51

44

1.48

-

3/4"

1/2"

37

43

36

29

90

82

52

230V/1/50Hz

44

8600

6930

5200

754

608

456

22

15

9

4,950

4,140

3,170

765

617

463

23

15

9

-

-

-

-

-

-

-

-

-

4450

3,590

2690

3300

2,640

1960

765

617

463

40.2

27

16.3

600

460

330

2

17

9

6

0.28

55

50

41

47

42

33

1.9

3/4"

-

-

90

82

52

50

8191

7529

5021

718

660

440

15

13

6

4,870

4,480

3,000

721

604

432

15

11

6

4,380

3,940

3,220

384

346

282

35

30

21

4190

3,510

2510

3000

2,540

1790

721

604

432

19.3

14

7.6

720

600

400

2

37

20

8

0.35

56

51

42

48

43

34

1.48

-

3/4"

1/2"

90

86

60

54

10100

8759

6241

886

768

547

23

18

9

6,100

5,220

3,700

855

743

533

22

17

9

-

-

-

-

-

-

-

-

-

4970

4,320

3100

3540

3,060

2170

855

743

533

25.9

21

11.7

720

600

400

2

37

20

8

0.35

56

53

44

48

45

36

1.9

3/4"

-

-

90

86

60

56

H maximum speed; M medium speed; L minimum speed

Heating

2-pipe system configuration

(1) Ambient air temperature 20°C d.b.; Inlet water temperature 70°C; DT water 10°C

2-pipe system configuration (EUROVENT)

(2) Ambient air temperature 20°C d.b.; Inlet water temperature 50°C; Water flow rate the same as in Cooling mode

4-pipe system configuration with additional heat exchanger

(3) Ambient air temperature 20°C d.b.; Inlet water temperature 70°C; DT water 10°C

Cooling (EUROVENT)

(4) Ambient air temperature 27°C d.b./19°C w.b.; Inlet water temperature 7°C; DT water 5°C

(5) Sound power based on the measurements carried out in accordance with Eurovent 8/2 standard

(6) Sound pressure level (A weighted) measured in environment with volume V=85m3 , reverberation time t=0.5s directivity factor Q=2; distance r=2.5m

Note: For further information, refer to the selection program or to the technical documentation on www.aermec.com

1.9

-

3/4"

1/2"

90

86

60

42

48

43

34

2

37

20

8

0.35

56

51

4600

3,850

2760

3500

3,070

2120

791

662

475

38

28

15.1

720

600

400

42

33

19

5,380

4,840

3,680

791

662

475

22

20

15

9648

8434

6056

846

740

531

-

-

-

-

-

-

-

-

-

80

15140

13349

10771

1328

1171

945

21

16

11

7,960

6,860

5,200

1189

860

738

21

12

9

6,410

6,300

5,300

562

553

465

15

14

11

6910

5,000

4290

5680

3,780

2970

1189

860

738

22

12

9.3

1140

930

700

2.52

-

3/4"

1/2"

90

84

45

51

53

48

43

3

80

40

30

0.49

61

56

36

84

17100

14421

11198

1500

1295

982

32

23

15

10,200

8,600

6,700

1479

1259

992

31

23

15

-

-

-

-

-

-

-

-

-

3.4

3/4"

-

-

90

84

45

51

53

49

43

3

80

40

30

0.49

61

57

8600

7,320

5770

5780

4,870

2800

1479

1259

992

29.5

22

14.7

1140

930

700

Technical data (Eurovent FCPH)

Mod. FCXI_P with static pressure Speed

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

(1) W H

Thermal power (70°C) (1)

(1)

(1)

W

W l/h

M

L

H

Water flow rate pressure drops

(1)

(1)

(1)

(1) l/h l/h kPa kPa

M

L

H

M

20

2772

2665

1754

243

234

154

24

3611

3426

1968

317

301

173

30

4730

4420

3154

415

388

277

Thermal power (50°C)

(1)

(2)

(2)

(2)

(2) kPa

W

W

W l/h

L

H

M

L

H

5

5

2

1640

1600

1000

232

4

3

1

2136

2026

1171

267

14

12

7

2700

2560

1810

365

Water flow rate (2)

(2)

(2)

(2) l/h l/h kPa kPa

M

L

H

M

220

131

5

5

253

162

3

2

342

222

6

6 pressure drops

(2) kPa L 2 1 5

HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)

Thermal power (70°C)

Water flow rate

Pressure drops

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

W

W

W l/h l/h l/h kPa kPa kPa

H

M

L

H

M

L

H

M

L

1670

1620

1120

144

139

96

6

6

3

COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)

Total cooling capacity

Sensitive cooling capacity

Water flow rate

Water pressure drops

Air flow rate

Centrifugal

Useful static pressure

Input power

Maximum input current

Sound power level

(Inlet+radiator)

Sound power level

(outlet)

Water content

Coil connections

(4)

(4)

(4)

(4)

(4)

(4)

(4)

(4)

(4)

(4)

(4)

(4)

(5)

(5)

(5)

(6)

(6)

(6)

W

W

W

W

W

W l/h l/h l/h kPa kPa kPa m3/h m3/h m3/h type dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l

ø (4R)

ø (3R)

ø (1R)

W

W

W

(A) n°

Pa

Pa

Pa

H

M

L

M

L

L

H

M

L

H

M

H

M

L

H

H

M

L

H

M

L

H

M

L

H

M

L

58

57

37

54

53

33

0,79

-

1/2"

1/2"

1

57

50

14

30

25

8

131

5

4

2

257

240

123

1350

1280

760

1130

1070

590

232

220

-

-

-

-

-

-

-

-

-

1555

1469

940

1243

1173

690

267

253

162

3

2

1

257

240

123

1

57

50

14

30

25

8

58

57

37

54

53

33

1

3/4"

-

-

2750

2640

1940

237

227

167

26

24

8

2

59

50

16

40

31

10

46

32

1,11

-

52

50

36

48

1/2"

1/2"

222

26

23

11

424

390

225

2120

1990

1290

1640

1540

980

365

342

Work percentage compared to the configuration signal

Electric power supply

%

%

%

H

M

L

90

84

44

90

84

44

90

84

48

H maximum speed; M medium speed; L minimum speed

Heating

2-pipe system configuration

(1) Ambient air temperature 20°C d.b.; Inlet water temperature 70°C; DT water 10°C

2-pipe system configuration (EUROVENT)

(2) Ambient air temperature 20°C d.b.; Inlet water temperature 50°C; Water flow rate the same as in Cooling mode

4-pipe system with additional heat exchanger (EUROVENT)

(3) Ambient air temperature 20°C d.b.; Inlet water temperature 70°C; DT water 10°C

Cooling (EUROVENT)

(4) Ambient air temperature 27°C d.b./19°C w.b.; Inlet water temperature

7°C; DT water 5°C

(5) Sound power based on the measurements carried out in accordance with

Eurovent 8/2 standard

(6) Sound pressure level (A weighted) measured in environment with volume

V=85m3 , reverberation time t=0.5s directivity factor Q=2; distance r=2.5m

34

-

-

-

-

-

-

-

-

-

2

59

50

16

40

31

10

46

32

1,5

3/4"

52

50

36

48

-

-

90

84

48

266

13

11

5

424

390

225

2671

2495

1544

2035

1898

1042

459

429

8

7

3

3331

3129

2039

459

429

266

7

6

3

5600

5262

3442

491

462

302

Dimension and weight data

A

36

4730

4420

3154

415

388

277

14

12

7

2801

2620

1858

364

343

221

11

10

4

2750

2640

1940

241

232

170

26

24

14

2117

1996

1284

1665

1551

968

364

343

221

26

24

11

424

390

225

2

59

50

16

40

31

10

52

50

36

48

46

32

1,5

-

3/4"

1/2"

90

84

48

3020

2820

1920

2310

2150

1450

519

485

330

12

10

5

515

470

300 centrifugal

2

60

50

20

48

38

16

55

53

43

51

49

39

1,48

-

3/4"

1/2"

90

82

52

230V/1/50Hz

D

40

3210

3070

2430

276

264

209

18

17

11

13

12

7

4050

3850

2800

519

485

330

10

9

4

6852

6499

4764

601

570

418

Mod FCXI_P

Height

Width

Depth

Weight

A mm

B* mm

D mm

C mm kg

44

18

15

8

4550

4219

2856

678

629

424

18

16

8

7610

7056

4777

668

619

419

49

39

1,9

3/4"

-

-

55

53

43

51

90

82

52

424

32

28

14

515

470

300

3942

3656

2468

2908

2690

1794

678

629

2

60

50

20

48

38

16

-

-

-

-

-

-

-

-

-

C

50

51

41

1,48

-

57

55

45

53

3/4"

1/2"

90

86

60

464

16

15

9

630

600

410

3800

3670

2700

2880

2770

2030

654

631

2

55

50

23

60

50

18

4090

3990

3280

352

343

282

31

31

22

54

12

12

7

4657

4488

3297

657

635

465

12

11

6

7815

7531

5534

686

661

485

743

544

18

17

10

19

18

10

5429

5222

3802

772

9106

8759

6375

799

768

559

12

12

7

4650

4480

3350

654

631

464

12

10

10

7815

7531

5534

686

661

485

51

41

1,9

3/4"

57

55

45

53

-

-

90

86

60

544

22

20

12

630

600

410

4488

4320

3165

3184

3061

2217

772

743

2

55

50

23

60

50

18

-

-

-

-

-

-

-

-

-

56

51

41

1,9

-

57

55

45

53

3/4"

1/2"

90

86

60

465

16

15

9

630

600

410

3821

3692

2704

2837

2756

2061

657

635

2

55

50

23

60

50

18

4090

3990

3280

352

343

282

31

31

22

80

58

55

38

54

51

34

2,52

-

3/4"

1/2"

90

84

45

487

13

12

4

799

730

405

5240

4860

2830

3930

3640

2090

901

836

3

60

50

15

78

61

23

6100

5700

3530

525

490

304

12

10

5

84

B

C

D

20 /24 30/34 /36 40/44 50/54/ 56 80/84

453 453 453 453 558

562

522

216

13

A

793

753

216

18

1013

973

216

22

B

1013

973

216

22

1147

1122

216

33

51

34

3,4

3/4"

-

-

58

55

38

54

90

84

45

611

18

15

6

799

730

405

6456

5981

3552

4270

3944

2311

1110

1029

3

60

50

15

78

61

23

-

-

-

-

-

-

-

-

-

11960 12623

11144 11635

6521

1049

978

572

6618

1107

1021

581

14

12

5

7000

6500

3800

901

836

487

11

9

4

18

16

6

7542

6954

3965

1.110

1.029

611

18

16

6

Aermec reserves the right to make all the modifications deemed necessary for improving the product, including technical data.

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italia

Tel. 039 0442633111 - Telefax +39 044293577 www.aermec.com

37

Omnia UL

Fan coils

Ceiling installations

Aermec

participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com

Features

• UL (Universal Line) fan coils for both horizontal and vertical installation

Versions:

UL-P Without cabinet for ceiling installation

Fan cleaning: Omnia fan coils allow fan blades to be easily cleaned. It is now possible to remove the fan volute (it contains the fan blades) and clean it periodically.

Condensate drip tray cleaning: Thanks to a new drip tray fitting, it is now easier to clean it with Omnia fan coils. This important solution avoids, in the long run, bacteria, germs and mould to grow up, in the drip tray because of the air humidity.

Precharged electrostatic filter: Omnia fan coils have, as standard, precharged electrostatic filters. These filters, thanks to their special execution, attracts and retains all suspended dust particles, thus garanteeing pure breathable air to the whole family.

PLASMACLUSTER ionising filter:

Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them. Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions neutralise the gas pollutant molecules, forming products that are normally present in clean air. The result is in the air: you can finally breath clean, odour-free ionised air.

Silent operation: Thanks to the use of special centrifugal fans, Omnia fan coils operation is extremely silent and offers the maximum acoustic comfort.

• 3-speed centrifugal fan

• Very quiet operation

• Slim dimensions

• Water connections reversibility during installation

• Low pressure drop across heat exchanger

• Motors with permanently connected condensers

• Easy installation and maintenance

• Air filter easy to remove and to clean

• Full compliance with safety regulations

Accessories

BC: Auxiliary condensate drip tray.

BC 10 for vertical installation

BC 20 for horizontal installation

DSC5: Condensate drainage device for use when natural run-off is not possible. DSC5 is not compatible BC10 - BC20 accessories.

SIT 3-5: Thermostat interface cards. They allow to set up a fancoils network (max. 10) commanded by a centralised panel (switch or thermostat).

SIT3: commands the three speeds of the fan and must be installed on each fancoil of the network; it receives the commands from the switch or from the SIT5 card.

SIT5: commands the 3 fan speeds and up to two valves (four-pipe systems); it sends the thermostat commands to the fancoils network.

SW: Water probe wich enables automatic season change-over thanks to the specific electronic thermostats.

SWA: External probe accessory SWA (length L

= 6m). It detects the temperature of the room air if connected to the connector (A) of the

FMT21 panel. The room air temperature probe, incorporated in the panel, is automatically disabled. It detects the temperature of the water in the system for ventilation consent if connected to the connector (W) of the

FMT21 panel. Two SWA probes can be connected simultaneously to the FMT21 panel.

VCH: Kit comprising motorized 3-way valve, unions and copper pipes.

VCHD: Kit comprising motorized 2-way valve, unions and copper pipes.

ZU: Feet for floor-standing solutions.

Control panels and VMF System: The control panels are described in a separate document.

38

Omnia UL_P

FMT21

PX2 o PX2C6

PXAE

TPF

WMT05

WMT10

VMF-E4 o E4D

VMF-E0 o E1

AMP10

BC10

BC20

DSC5

SIT3

SIT5

SW3

SWA

VCH

VCHD

(1)

(2)

11

16

26

36

(1) PX2C6, PX2 panel in multiple 6-piece pack.

(2) The DSC5 accessory is not compatible BC10 - BC20 accessories.

Technical data

Mod.

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

(1) W

Heating capacity (70°C)

(1)

(1)

W

W

Water flow rate

Pressure drop

Heating capacity (50°C)

Water flow rate

Pressure drop

(1)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(1)

(1)

(1)

(1)

(1) kPa

W

W

W l/h l/h l/h kPa kPa kPa l/h l/h l/h kPa kPa

COOLING PERFORMANCE

Total cooling capacity

Sensible cooling capacity

Water flow rate

Pressure drop

Air flow rate

Fans

Absorbed power

Max. input current

Sound power level

Sound pressure level

Water content

Coil connections

(5)

(5)

(5)

(4)

(4)

(4)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3) n°

W

W

W

(A) dB(A) dB(A) dB(A) dB(A) dB(A) l dB(A) l/h l/h l/h kPa kPa kPa m

3

/h m

3

/h m

3

/h type

W

W

W

W

W

W

ø

Speed connected

Vel.

M

L

L

H

H

M

M

L

L

H

H

M

L

H

M

H

M

L

M

L

L

H

H

M

L

H

M

H

M

L

H

M

L

H

M

L

H

M

L

H

M

L

H

M

L

UL11P

1

1150

870

650

144

117

93

2

1

1

2010

1460

1060

176

128

93

2

1

144

117

93

1,9

1

1

180

120

80

840

680

540

700

530

390

0,09

46

37

31

1

18

12

8

37,5

28,5

22,5

0,4

1/2"

V3

V2

V1

UL16P

1

1700

1250

930

206

153

122

4

2

2

2910

2120

1540

255

186

135

4

2

206

153

122

4,8

3

2

240

160

110

1200

890

710

990

710

540

1

32

25

23

0,15

48

43

34

39,5

34,5

25,5

0,5

1/2"

V3

V2

V1

Centrifugal

UL26P

5

2750

2240

1670

349

289

220

10

7

4

4620

3830

2890

405

336

253

11

8

349

289

220

11

9

5

350

270

190

2030

1680

1280

1640

1330

990

0,18

48

43

35

2

35

27

24

39,5

34,5

26,5

0,8

1/2"

V3

V2

V1

Power supply

230V/1/50Hz

H max. speed; M med. speed; L min. speed

Heating mode

2 pipes system configuration

(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; DT water 10°C

2 pipes system configuration (EUROVENT)

(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode

Cooling mode (EUROVENT)

(3) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C

(4) Sound power level on the basis of measurements made in compliance with Eurovent 8/2

(5) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m

Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

UL36P

487

394

286

18,9

12

7

460

350

240

2830

2290

1660

2040

1620

1160

2

42

35

30

0,22

50

43

34

39,5

32,5

25,5

1,1

1/2"

V3

V2

V1

3

3540

2860

2080

487

394

286

16

11

6

5940

4870

3530

521

427

310

7,7

5,4

Dimensions (mm)

Mod Omnia

Height

Widht

Depth

Weight

*overall dimensions

UL 11P UL 16P UL 26P UL 36P

A 465 465 465 465

B* 420.5

530.5

761.5

981.5

D 360.5

470.5

701.5

921.5

C kg

171

10.2

171

11.6

171

14.9

171

18.3

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

A

D

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italy

Tel. 0442633111 - Telefax 044293577 www.aermec.com

B

C

D

A

C

B

Mod Omnia

Height

Widht

Depth

Height with feet

Weight

C

D

A

B kg

UL 11 UL 16 UL 26 UL 36

513

640

513

750

513

980

513

1200

173

93

12,5

173

93

13,5

173

93

16,5

173

93

19,5

39

VED

Fan coil unit

For ducted installations with cooling capacity from 0.99 to 5.82kW

Aermec participates in the EUROVENT

Certification Programme FCP. The products of interest can be found on the site: www.eurovent-certification.com

• HORIZONTAL OR VERTICAL INSTALLATION

• VERSIONS FOR 2/4 PIPE SYSTEMS

• 1 ROW HEATING ONLY COIL (ACCESSORY BV)

• LARGE RANGE OF AVAILABLE STATIC PRESSURE

• ACCESSIBLE FAN ASSEMBLY

• AIR FILTER CLASS G3

• REVERSIBLE COIL

Unit selection

By choosing the appropriate options it is possible to select the model to suit the specific system requirements.

Configuration fields:

1 2 3

Code

4

Size

5

Main Coil

6

0

Example:

1 2 3

VED

4

0

(VED030 = unit Size 0, with 3 Row Main Coil)

5

3

6

0

Characteristics

• Ducted air conditioning terminal unit

• Horizontal and vertical installation

• Internal installation

• Available in 8 sizes

• 3 or 4 row coils for 2-pipe systems

• 3 row main coil and heating only coil accessory for 4-pipe systems

• Reversing of hydraulic connections side on site

• Low pressure drop heat exchanger

• 3-way valve accessory

• 2-way valve accessory for variable flow systems

• 6 and 7 speed fan assembly (3 selectable)

• Large range of available static pressure

• Centrifugal fans in anti-static plastic material.

Their characteristics permit energy savings compared to conventional fans

• Fans with aerofoil profile designed to achieve high airflows and pressures whilst at the same time producing low noise

• Compatible with the VMF system

• Large range of controllers

• Large range of accessories to satisfy all installation requirements

• Compatible with many accessories already available on the FCX range

• Discharge connection supplied loose

• Air filter Class G3, for easy removal and cleaning

• Internal insulation in Class 1 fire retardant material

• Protective rating IP20

• Fan housing in plastic material removable for easy and effective cleaning

• Ease of installation and maintenance

• Full compliance with safety standards.

40

Accessories

DUCTING ACCESSORIES

Plenum in galvanised sheet steel and connections:

RDA_V: Straight intake connection with rectangular flange.

RDAC_V: Straight intake connection with circular flanges.

RPA_V: Intake plenum with rectangular flange.

RDMC_V: Straight discharge with circular flanges. Internally insulated.

PA_V: Intake plenum with circular flanges.

Flanges in plastic material.

RPM_V: Discharge plenum with rectangular flange. Internally insulated.

PM_V: Discharge plenum with circular flanges. Internally insulated. Flanges in plastic material.

KFV10: Circular flanges kit for intake/discharge plenum.

Discharge and intake grilles:

GA: Intake grille with fixed louvres.

GAF: Intake grille with fixed louvres with filter.

GM: Discharge grille with adjustable louvres.

SE: External air damper with manual control.

INSTALLATION ACCESSORIES

BC: auxiliary condensate drain tray.

DSC4: Condensate pump to overcome lifts.

ZX: Feet for recessed installation.

HEATING ONLY COIL

BV: 1 row heating only coil.

WATER VALVES

For main coil, 230V~50 Hz / 24V~50 Hz

VCF43 / 4324: Kit composed of 3-way motorised valve with insulating casing, connections and insulated copper tubes.

VCFD3 / 324: Kit composed of 2-way motorised valve with insulating casing, connections and insulated copper tubes.

For heating only coil, 230V~50 Hz / 24V~50 Hz

VCF45 / 4543: Kit composed of 3-way motorised valve, with connections and insulated copper tubes.

VCFD4 / 424: Kit composed of 2-way motorised valve, with connections and insulated copper tubes.

VCF3X4: Valve kit for 4 pipe systems and fan coil units with single coil and 2 connections.

Kit composed of

special 3 way motorised valve with insulating casing, connections and insulated copper tubes.

Version VCF3X4L for left hand connection fan coils.

Version VCF3X4R for right hand connection fan coils.

Power supply 230V ~ 50Hz.

CONTROL PANELS

The complete characteristics of the control panels are described in the dedicated files.

Some control panels require combination with other accessories; consult the relevant documentation.

ACCESSORIES TO COMBINE TO CONTROL

PANELS

SIT 3 - 5: Thermostat Interface Boards. Allows networking of fan coil units (10 max) controlled by a central panel (switch or thermostat).

SIT3: Controls the 3 speeds of the fan and must be installed on each fan coil unit on the network; receives controls from the switch or the

SIT5 board.

SIT5: Thermostat interface board. Allows a network of VED units (3 max) controlled by a single panel PXAE.

SW3: Water temperature sensor for control panel PXAE.

SWA: Air and water temperature sensor for control panel FMT21.

VARIABLE MULTI FLOW SYSTEM

VMF System: The complete characteristics of the

VMF system are described in the dedicated files.

Some VMF components require combination with other accessories; consult the relevant documentation.

Accessory Compatibility

PM000V ***

PM100V ***

PM200V ***

PM300V ***

RPM000V ***

RPM100V ***

RPM200V ***

RPM300V ***

RDMC000V

RDMC100V

RDMC200V

RDMC300V

BV030

BV130

BV230

BV162

KFV10

VMF-EO

VMF-E1

VMF-SW

VMF-SW1

VMF-E4/E4D

VMF-E5N/E5B

FMT10

FMT21

TPF

Mod.VED

RDA000V

RDA100V

RDA200V

RDA300V

RPA000V ***

RPA100V ***

RPA200V ***

RPA300V ***

RDAC000V

RDAC100V

RDAC200V

RDAC300V

PA000V ***

PA100V ***

PA200V ***

PA300V ***

030 040

• •

130 140

230 240

330 340

GAF22

GAF32

GAF42

GAF62

GM22

GM32

GM42

GM62

SE20X ****

SE30X ****

SE40X ****

SE80X ****

ZX7

ZX8

Mod.VED

SWA

KTLP

PX

PX2 - PX2C6

PXAR

PXAE

WMT05

WMT06

WMT10

SW3

SIT3

SIT5

VCF43-4324 *

VCF45-4524 *

VCFD3-324 *

VCFD4-424 *

VCF3X4R

VCF3X4L

AMP

BC4 * / **

BC6 **

BC9 **

DSC4 **

GA22

GA32

GA42

GA62

030 040 130

• • •

140 230

• •

240 330

• •

340

* The valve kits VCF and the drain pan BC4 cannot be installed together on the same fan coil unit.

** The accessory DSC4 is not compatible with AMP and BC4 - BC6 - BC9.

*** All the Plenums ( RPA_V; PA_V; RPM_V; PM_V ) have a circular push-outs

(Ø=150mm ) on both sides, which can be removed and used with accessories.

All the Plenums ( RPA_V; PA_V; RPM_V; PM_V ) can have intake/discharge either straight or downwards (straight or downwards with reference to horizontal installation).

**** Accessories SE must be combined with the feet ZX.

41

Technical data

Mod.

VED

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

(1) W

Heating capacity (70°C) (1) W

(1) W

(1) l/h

Water flow rate

Pressure drop

(1) l/h

(1) l/h

(1) kPa

(1) kPa

(1) kPa

(2) W

Heating capacity (50°C) (2) W

(2) W

(2) l/h

Vel.

L

H

M

L

H

M

M

L

H

L

H

H

M

030

3688

3374

1820

323

296

160

9

7

3

2180

1990

1100

279

-

-

-

-

-

-

-

-

-

030*

BV030

-

-

-

-

040

Water flow rate (2) l/h

(2) l/h

(2) kPa

(2) kPa

M

L

H

M

250

170

8

7 -

-

-

-

Pressure drop

(2) kPa L 3 -

HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)

(3) W H 2220

Heating capacity (70°C) (3) W M 2080

296

193

12

10

5

-

-

Water flow rate

(3) W

(3) l/h

(3) l/h

(3) l/h

(3) kPa

L

H

M

L

H

Pressure drop (3) kPa

(3) kPa

M

L

COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)

(4) W H

Total cooling capacity (4) W M

-

-

-

-

-

-

-

1590

196

183

140

8

7

5

-

-

-

-

-

-

-

Sensible cooling capacity

Water flow rate

Pressure drop

Air flow rate

Fans

High static pressure

Absorbed power

Max. input current

Sound power level (inlet+radiator)

Sound power level (outlet)

(4)

(4)

(4)

(4)

(4)

(4) l/h

(4) l/h

(4) kPa

(4)

(4)

(5)

W

W

W

W l/h kPa kPa m m m type n°

Pa

Pa

Pa

W

W

W

3

3

3

(A)

/h

/h

/h dB(A)

(5) dB(A)

(5) dB(A)

(5) dB(A)

(5) dB(A)

(5) dB(A)

L

H

M

L

H

M

L

H

M

L

H

M

L

H

M

L

H

M

L

H

M

L

H

M

L

1624

1454

990

1242

1116

750

279

250

170

9

7

3

285

256

161

1

61

50

21

59

38

23

0,37

54

52

44

50

48

40

1592

1416

984

1218

1094

745

274

244

169

9

7

3

280

250

160

1

61

50

21

59

38

23

0,37

54

52

44

50

48

40

52

44

50

48

40

58

38

23

0,37

54

1

61

50

21

296

193

14

12

5

277

249

160

1900

1720

1120

1350

1230

810

327

Water content

Water content (additional heat exchanger)

Coil connections

Coil connections (additional heat exchanger)

Speed connected l l

ø Gas (F)

ø Gas (F)

H

M

L

3/4"

-

V6

V4

V1

3/4"

1/2"

V6

V4

V1

3/4"

-

V6

V4

V1

Power supply

3916

3568

2366

343

313

207

12

10

4

2340

2130

1410

327

130

-

-

-

-

-

-

-

-

-

-

-

-

-

-

330*

BV162

-

-

-

-

760

633

16

13

9

16

13

9

6270

5580

4670

860

10507

9343

7813

921

819

685

624

499

31

26

13

3

26

18

4750

4290

3450

691

7909

7141

5800

684

616

499

-

-

-

-

-

-

-

-

-

-

-

-

-

-

230*

BV230

-

-

-

-

538

445

35

29

20

37

30

27

4320

3920

3230

588

7160

6500

5350

616

559

460

525

390

19

16

9

18

16

9

3940

3650

2710

566

6575

6089

4518

576

534

396

-

-

-

-

-

-

-

-

-

-

-

-

-

-

130*

BV130

-

-

-

-

480

358

27

23

13

26

22

13

3750

3480

2620

516

6289

5833

4397

551

511

385

76

53

34

0,41

55

2

60

50

26

53

47

50

48

42

480

358

31

27

15

433

397

287

2997

2790

2080

2090

1940

1440

515

-

-

-

-

-

-

-

-

-

3/4"

-

V6

V4

V1

76

53

34

0,41

55

2

60

50

26

53

47

50

48

42

469

349

31

27

15

423

388

280

2931

2727

2029

2169

1900

1400

504

3780

3596

2946

331

315

258

28

25

17

3/4"

1/2"

V6

V4

V1

140

-

-

-

-

-

-

-

-

-

230

525

390

23

20

11

420

386

280

3290

3050

2270

2370

2190

1610

566

53

47

50

48

42

75

52

34

0,41

55

2 centrifugal

2

60

50

26

64

50

32

93

57

43

0,58

57

54

49

42

49

44

538

445

44

36

25

590

524

417

3420

3130

2590

2700

2440

2000

588

3/4"

-

3/4"

-

V6

V4

V1

V6

V3

V1

230V/1/50Hz

-

-

-

-

-

-

-

-

-

93

57

43

0,58

57

2

64

50

32

54

49

42

49

44

530

430

42

35

23

582

513

412

3380

3080

2500

2600

2350

1900

581

4493

4171

3675

394

366

322

16

14

11

3/4"

1/2"

V7

V3

V1

240

92

57

43

0,58

57

2

63

50

32

54

49

42

49

44

624

499

37

31

16

570

509

406

4020

3630

2900

3015

2718

2200

691

-

-

-

-

-

-

-

-

-

3/4"

-

V6

V3

V1

330

104

75

63

0,66

58

3

66

50

33

55

38

54

51

34

-

-

-

-

-

-

-

-

-

760

633

18

14

10

805

704

572

5000

4420

4946

4380

3680

3738

3600

3670

3337,5 3280

2800 2720

860 851

753

619

18

14

9

790

695

568

3/4"

-

V7

V3

V1

104

75

63

0,66

58

3

66

50

33

55

38

54

51

34

5888

5499

4896

515

482

429

26

23

19

3/4"

1/2"

V7

V3

V1

340

103

74

63

0,66

58

3

64

50

34

55

38

54

51

34

824

685

26

21

16

775

685

563

5360

4790

3980

3990

3570

2950

922

-

-

-

-

-

-

-

-

-

3/4"

-

V7

V3

V1

H max. speed; M med. speed; L min. speed

Heating mode

2 pipes system configuration

(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C;

ΔT water 10°C

2 pipes system configuration (EUROVENT)

(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode

* 4 pipes system configuration (with additional heat exchanger) (BV)

(3)Room air temperature 20°C b.s.; Inlet water temperare 70°C;

ΔT water 10°C

Cooling mode (EUROVENT)

(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C;

ΔT water 5°C

(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2

VED30÷240

V1 V2 V3 V4 V5 V6 Speed

V1 V2 V3 V4 V5 V6 V7

L7 L6 L5 L4 L3 L2 L1

VED330÷340

Note: The speed of associates may differ from the standard factory configuration, for more information refer to the program selection and the technical documentation available on the website www.aermec.com

42

824

685

21

17

13

32

28

22

6550

5980

4970

922

10951

10017

8312

960

878

729

Dimensions (mm)

VED: 030 - 040 - 130 - 140 - 230 - 240 - 330 - 340

25

D

A

B

C

Asola 20x9

25

24

217

167 24

41

96

156

149

Ø20,5

Ø17,5

VED

C

D

A

B

Net weight mm mm mm mm kg

030

576

550

500

530

20

040

576

550

500

530

21

130

807

781

731

761

23

140

807

781

731

761

24

230

1027

1001

951

981

29,5

240

1027

1001

951

981

32

330

1148

1122

1072

1102

32,5

340

1148

1122

1072

1102

34

The technical data shown in this documentation is not binding.

Aermec S.p.A. reserves the right to make all modification deemed necessary for improving the product at any time.

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italia

Tel. 0442633111 - Telefax 044293577 www.aermec.com

43

VED

Air handling terminal with cooling capacities from 8 to 18 kW

For ducted systems

AERMEC partecipates in the

EUROVENT programme for: FCP

Check ongoing validity of certificate online: www.eurovent-certification.com

• HORIZONTAL AND VERTICAL INSTALLATION

• VERSIONS FOR 2/4 PIPE SYSTEMS

• HEAT EXCHANGER ONLY WITH 1 OR 2 ROWS

• WIDE RANGE OF USEFUL STATIC PRESSURE

• 5 SPEED VENTILATION UNIT

• INSPECTIONABLE FAN UNIT

• CLASS G3 AIR FILTER

• COIL REVERSIBILITY

Choosing the unit

By appropriately combining the options available, it is possible to select the model that satisfies the specific system requirements.

Fields configurator:

1 2 3

Code

4

Size

5

Main coil n°. rows

6

Heating only coil n°. rows

1 2 3

VED

4

5

5

3

6

2

(VED532 = unit size 5, with Main Coil 3 Rows and Heating Coil 2 Rows)

Features

• Air handling terminal for ducted systems

• EUROVENT FCP Certification Program

• Horizontal and vertical installation

• Indoor installation

• Available in 4 sizes and 4 configurations

• Versions for 2 pipe systems with 3 or 4 row coil

• Versions for systems with 4 pipes with main coil with 3 or 4 rows and heating only coil with 1 or 2 rows

• Reversibility of the hydraulic connection in the installation phase

• Low pressure drop in the heat exchange coils

• 3-way valves accessories

• 2-way valves accessories for systems with variable water flow rate

• 5 speed fan unit (3 selectable)

• Wide range of useful static pressure

• Centrifugal fans in antistatic plastic. Due to their features, they allow to reduce the energy consumption with respect to normal fans

• Fans with wing-shaped profile studied to obtain high flow rate and static pressure performance and low noise emission at the same time

• Compatible with the VMF system

• Wide range of controls

• Wide range of accessories to satisfy all system requirements

• Rectangular flow flange already integrated into the framework

• Class G3 air filter with easy extraction and cleaning

• Internal insulation in Class 1 fire resistance

• IP20 protection rating

• Plastic augers, extractable for easy and efficient cleaning

• Easy installation and maintenance

• Full respect of the accident-prevention standards

44

Accessories

RDA_V: Straight fitting with rectangular flange for ducting.

In galvanised sheet steel

RPA_V: Intake plenum with rectangular flange for ducting.

In galvanised sheet steel

PA_V: Intake plenum with circular flanges for ducting.

In galvanised sheet steel, the flanges are in plastic

RPM_V: Flow plenum with rectangular flange for ducting.

In galvanised sheet steel, internally isolated.

PM_V: Flow plenum with circular flanges for ducting

In galvanised sheet steel, internally isolated, the flanges are in plastic

KFV: Circular flange kit for intake/flow plenum.

In plastic

VCF4_C: Kit made up from motorised 3-way valves with isolating shell, fittings and isolated copper pipes. For main coils.

230V~50 Hz power supply

VCF4_H: Kit made up from motorised 3-way valves, fittings and isolated copper pipes. For heating only coils. 230V~50 Hz power supply

VCF2_C: Kit made up from motorised 2-way valves, with fittings and isolated copper pipes. For main coils. 230V~50 Hz power supply

VCF2_H: Kit made up from motorised 2-way valves, with fittings and copper pipes.

For heating only coils. 230V~50 Hz power supply coupled to thermostats different to the VMF

System

SIT5: Thermostat interface board.

Allows to realise a network of VED units

(max 3) controlled by a centralised PXAE panel

SW3: Water minimum temperature probe to use with PXAE control panel.

CONTROL PANELS

The complete features of the control panels are described in the dedicated sheet.

Some control panels require coupling with other accessories, consult the relative documentation.

VARIABLE MULTI FLOW SYSTEM

VMF System: The complete fittings of the VMF

System management system are described in the dedicated sheet.

Some VMF components require coupling with other accessories, consult the relative documentation.

VMF-SIT 3 : Thermostat Interface Board

VMF. Mandatory accessory on the VED unit supplied with VMF-E0 / E1 thermostat.

ACCESSORIES TO COUPLE WITH THE

CONTROL PANELS

SIT3 : Thermostat interface board

Mandatory accessory on the VED units

Mod. VED

RDA 450 V

RDA 670 V

RPA 450 V

RPA 670 V

PA 450 V

PA 670 V

RPM 450 V

RPM 670 V

PM 450 V

PM 670 V

KFV

SW3

SIT 3*

SIT 5**

PXAE

WMT05

WMT06

WMT10

VCF45C

VCF45H

VCF47C

VCF47H

VCF25C

VCF25H

VMF-SIT3***

VMF-E0

VMF-E1

VMF-SW

VMF-SW1

VMF-E4/E4D

VMF-E5B

VMF-E5N

432

430

441

440

530

Accessories compatibility

532

540

541

630

• • •

• • •

• • •

• • •

• • •

• •

640

632

* SIT3

** SIT5

=Mandatory accessory on the VED units coupled to thermostats different to the VMF System

= Allows to realise a network of VED units (max 3) controlled by a centralised PXAE panel

*** VMF-SIT3 = Mandatory accessory for coupling with VMF-E0 or VMF-E1

641

732

730

741

740

45

Technical data

Mod.

VED

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

(1) W

Heating capacity (70°C)

Water flow rate

(1) W

(1) W

(1) l/h

(1) l/h

Pressure drop

Heating capacity (50°C)

Water flow rate

Pressure drop

(1) l/h

(1) kPa

(1) kPa

(1) kPa

(2) W

(2) W

(2) W

(2) l/h

(2) l/h

(2) l/h

(2) kPa

(2) kPa

(2) kPa

Vel.

430 432 440 441 530 532 540 541 630 632 640 641 730 732 740 741

H 15974 18110 17572 19908 27016 32688 28999 31706 -

M 13845 15358 16467 18586 22672 27744 25364 27650 -

L 10469 11445 13802 15377 18628 22454 21178 22883 -

H 1401

M 1214

L

H

M

918

19

14

-

-

-

-

-

1588

1347

1004

24

18

-

-

-

-

-

1541

1444

1211

21

18

-

-

-

-

-

1746

1630

1349

29

25

-

-

-

-

-

2370

1989

1634

58

43

-

-

-

-

-

2867

2434

1970

38

29

-

-

-

-

-

2544

2225

1858

67

55

-

-

-

-

-

2781

2425

2007

46

36

-

-

-

-

-

L

H

M

L

L 9

H 9470

M 8250

L 6200

H 1195

M 1058

805

17

11

7 -

-

-

-

-

-

-

-

11

10700 10420 11820 16070 17930 17280 19150 -

9130

6810

1378

1214

918

19

15

9

-

-

-

-

-

-

-

-

13

9780

8190

1335

1271

1060

16

15

11

-

-

-

-

-

-

-

-

18

11050

9170

1543

1469

1278

23

21

16

-

-

-

-

-

-

-

-

30

13500

11100

2155

1840

1529

48

36

26

-

-

-

-

-

-

-

-

19

14940

11980

2611

2195

1794

36

27

19

-

-

-

-

-

-

-

-

38

15120

12640

2382

2098

1789

57

44

33

-

-

-

-

-

-

-

-

26

16680

13840

2766

2448

2057

35

28

21 -

-

-

-

-

-

-

-

-

HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)

Heating capacity (70°C)

Water flow rate

Pressure drop

(3) W

(3)

(3) W

(3)

(3)

(3) l/h

(3) kPa

(3)

W l/h l/h kPa

H

M

L

H

M

L

H

M

-

-

-

-

-

-

-

-

12090

10725

8280

1060

940,7

726,2

18

14

-

-

-

-

-

-

-

-

8160

7480

6190

716

656

543

28

24

-

-

-

-

-

-

13540 -

12850 -

10720

1188

1127

940

22

20

-

-

-

-

-

-

8850

8520

7475

776

747

656

32

30

-

-

-

-

-

-

-

-

20513

17726

14665

1799

1555

1286

28

22

-

-

-

-

-

-

-

-

13750

12370

10770

1206

1085

945

28

23

-

-

-

-

-

-

-

-

22174

19726

16728

1945

1730

1467

33

26

-

-

-

-

-

-

-

-

14500

13300

11830

1272

1167

1038

30

26

(3) kPa L

COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)

(4) W

9 17 14 24 16 18 20 21

H 6950 6950 8010 8010 7760 7760 8970 8970 12530 12530 15180 15180 13850 13850 16080 16080

Total cooling capacity

Sensible cooling capacity

(4) W

(4) W

(4) W

(4) W

(4) W

M 6150 6150 7060 7060 7390 7390 8540 8540 10700 10700 12760 12760 12200 12200 14230 14230

L 4680 4680 5340 5340 6160 6160 7430 7430 8890 8890 10430 10430 10400 10400 11960 11960

H 5360 5360 5730 5730 6020 6020 6450 6450 10300 10300 10660 10660 11440 11440 11320 11320

M 4710 4710 5040 5040 5710 5710 6130 6130 8750 8750 8910 8910 9990 9990 9970 9970

L 3540 3540 3780 3780 4720 4720 5040 5040 7220 7220 7240 7240 8480 8480 8340 8340

Water flow rate

Pressure drop

Air flow rate

Fans

(4) l/h

(4) l/h

(4) l/h

(4) kPa

(4) kPa

(4) kPa m 3 /h m 3 /h m

3

/h type

H 1195 1195 1378 1378 1335 1335 1543 1543 2155 2155 2611 2611 2382 2382 2766 2766

M 1058 1058 1214 1214 1271 1271 1469 1469 1840 1840 2195 2195 2098 2098 2448 2448

L

H

M

805

17

13

805

17

13

918

22

17

918 1060 1060 1278 1278 1529 1529 1794 1794 1789 1789 2057 2057

22

17

21

19

21

19

28

25

28

25

48

36

48

36

41

30

41

30

58

46

58

46

45

37

45

37

L 8 8 10 10 12 12 19 19 26 26 21 21 35 35 27 27

H 1350 1250 1340 1250 1520 1460 1500 1460 2210 2110 2440 2110 2410 2350 2350 2350

M 1130 1060 1100 1060 1400 1360 1380 1360 1800 1730 2004 1730 2040 2000 2000 2000

L 790 750 780 750 1120 1060 1100 1060 1380 1340 1567 1340 1640 1600 1600 1600 centrifugal

High static pressure

Absorbed power

Max. input current n°

Pa

Pa

Pa

W

W

W

(A)

H

M

L

H

2

72

50

24

2

70

50

25

2

70

50

24

2

70

50

25

2

58

50

32

2

56

50

32

2

56

50

32

2

56

50

32

3

75

50

30

3

75

50

30

3

75

50

30

3

75

50

30

3

69

50

32

3

69

50

32

3

69

50

32

3

69

50

32

228 215 222 215 270 266 267 266 339 340 340 340 371 372 371 372

M 175 175 178 175 232 229 230 229 268 264 260 264 285 288 285 288

L 137 130 135 130 175 170 172 170 224 223 220 223 234 227 234 227

Sound power level (inle+radiator)

Sound power level (outlet)

Water content

Water content (additiona heat exchanger)

Coil connections

Coil connections (additiona heat exchanger)

Speed connected

(5) dB(A)

(5) dB(A)

(5) dB(A)

(5) dB(A)

(5) dB(A)

(5) dB(A) l l

ø Gas (F)

ø Gas (F)

H

M

L

H

M

L

H

M

53

57

42

49

53

38

61

57

51

57

53

47

62

59

53

58

55

49

62

59

53

58

55

49

68

64

59

64

60

55

68

64

59

64

60

55

68

66

62

64

62

58

68

66

62

64

62

58

3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4”

-

V5

V3

1/2”

V5

V3

-

V5

V3

1/2”

V5

V3

-

V5

V4

1/2”

V5

V4

-

V5

V4

1/2”

V5

V4

-

V5

V3

1/2”

V5

V3

-

V5

V3

1/2”

V5

V3

-

V5

V3

1/2”

V5

V3

-

V5

V3

1/2”

V5

V3

Power supply

L V1 V1 V1 V1 V2 V2 V2 V2 V1

230V/1/50Hz

V1 V1 V1 V1 V1 V1 V1

H max. speed; M med. speed; L min. speed

Heating mode

2 pipes system configuration

(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C

2 pipes system configuration (EUROVENT)

(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode

VED430÷741

V1 V2 V3 V4 V5

Speed

4 pipes system configuration (with additional heat exchanger) (EUROVENT)

(3)Room air temperature 20°C b.s.; Inlet water temperare 70°C; ΔT water 10°C

Cooling mode (EUROVENT)

(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; ΔT water 5°C

(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2

Note: The speed of associates may differ from the standard factory configuration, for more information refer to the program selection and the technical documentation available on the website www.aermec.com

46

=

Dimensional data (mm)

VED: 430 - 432 - 440 - 441 - 530 - 532 - 540 - 541

1158

1133

1053

1158

1133

1053

1104

1109

=

10

15

300

256

45

109

241

198

10

15

275

300

256

Ø16

45

109

241

198

275

Ø16

1104

1109

VED

Weight Kg

430

41

VED: 630 - 632 - 640 - 641 - 730 - 732 - 740 - 741

432

46

440

43

441

46

530

42

532

47

540

47

541

47

40

1558

1533

1453

10

40

15

351

307

280 316

46

109

247

287

326

Ø16

1504

1509

VED

Weight Kg

630

57

632

57

640

60

641

60

730

58

732

64

740

61

741

64

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italy

Tel. 0442633111 - Telefax 044293577 www.aermec.com

47

VED_I

Fan coil unit with Brushless Inverter motor (EC) for ducted systems

Cooling capacities 0,99÷5,82kW

AERMEC

partecipates in the EUROVENT programme for: FCP

Check ongoing validity of certificate online: www.eurovent-certification.com

• HORIZONTAL OR VERTICAL INSTALLATION

• VERSIONS FOR 2/4 PIPE SYSTEMS

• 1 ROW HEATING ONLY COIL (ACCESSORY BV)

• LARGE RANGE OF AVAILABLE STATIC PRESSURE

• CENTRIFUGAL FANS INVERTER

• ACCESSIBLE FAN ASSEMBLY

• AIR FILTER CLASS G3

• REVERSIBLE COIL

Unit selection

By choosing the appropriate options it is possible to select the model to suit the specific system requirements.

Configuration fields:

1 2 3

Code

4

Size

5

Main Coil

6

Main coil only hot

7

Inverter motor

Example:

1 2 3

VED

4

0

5

3

6

0

7

I

Characteristics

• Ducted air conditioning terminal unit

• Internal installation

• 3 or 4 row coils for 2-pipe systems

• 3 row main coil and heating only coil accessory for 4-pipe systems

• Reversing of hydraulic connections side on site

• Low pressure drop heat exchanger

• 3-way valve accessory

• 2-way valve accessory for variable flow systems

• Centrifugal fans with motor inverter

• Large range of available static pressure

• Centrifugal fans in anti-static plastic material.

Their characteristics permit energy savings compared to conventional fans

• Fans with aerofoil profile designed to achieve high airflows and pressures whilst at the same time producing low noise

• Compatible with the VMF system

• Large range of controllers

• Large range of accessories to satisfy all installation requirements

• Discharge connection supplied loose

• Air filter Class G3, for easy removal and cleaning

• Internal insulation in Class 1 fire retardant material

• Protective rating IP20

• Fan housing in plastic material removable for easy and effective cleaning

• Ease of installation and maintenance

• Full compliance with safety standards.

48

Accessories

DUCTING ACCESSORIES

Plenum in galvanised sheet steel and connections:

RDA_V: Straight intake connection with rectangular flange.

RDAC_V: Straight intake connection with circular flanges.

RPA_V: Intake plenum with rectangular flange.

RDMC_V: Straight discharge with circular flanges. Internally insulated.

PA_V: Intake plenum with circular flanges.

Flanges in plastic material.

RPM_V: Discharge plenum with rectangular flange. Internally insulated.

PM_V: Discharge plenum with circular flanges. Internally insulated. Flanges in plastic material.

PMZ: Plenum with motorized dampers (for more details refer to the dedicated card).

KFV10: Circular flanges kit for intake/discharge plenum.

Discharge and intake grilles:

GA: Intake grille with fixed louvres.

Compatibilità accessori

ter.

GM: Discharge grille with adjustable louvres.

SE: External air damper with manual control.

INSTALLATION ACCESSORIES

AMP: Hanging kit.

BC: auxiliary condensate drain tray.

DSC4: Condensate pump to overcome lifts.

ZX: Feet for recessed installation.

HEATING ONLY COIL

BV: 1 row heating only coil.

WATER VALVES

For main coil, 230V~50 Hz / 24V~50 Hz

VCF43 / 4324: Kit composed of 3-way motorised valve with insulating casing, connections and insulated copper tubes.

VCFD3 / 324: Kit composed of 2-way motorised valve with insulating casing, connections and insulated copper tubes.

For heating only coil, 230V~50 Hz / 24V~50 Hz

VCF45 / 4543: Kit composed of 3-way motorised valve, with connections and insulated copper tubes.

VCFD4 / 424: Kit composed of 2-way motorised valve, with connections and insulated copper tubes.

VCF3X4: Valve kit for 4 pipe systems and fan coil units with single coil and 2 connections.

Kit composed of

special 3 way motorised valve with insulating casing, connections and insulated copper tubes.

Version VCF3X4L for left hand connection fan coils.

Version VCF3X4R for right hand connection fan coils.

Power supply 230V ~ 50Hz.

CONTROL PANELS

The complete characteristics of the control panels are described in the dedicated files.

Some control panels require combination with other accessories; consult the relevant documentation.

WMT21: Electronic thermostat wall-mount installation

SWAI: Air and water temperature sensor for

WMT21.

Variable Multi Flow System (VMF)

The complete characteristics of the VMF system are described in the dedicated files.

Some VMF components require combination with other accessories; consult the relevant documentation.

Mod.VED

RDA000V

RDA100V

RDA200V

RDA300V

RPA000V

RPA100V

RPA200V

RPA300V

RDAC000V

RDAC100V

RDAC200V

RDAC300V

PA000V

PA100V

PA200V

PA300V

PM000V

PM100V

PM200V

PM300V

PMZ

RPM000V

RPM100V

RPM200V

RPM300V

RDMC000V

RDMC100V

RDMC200V

RDMC300V

BV030

BV130

BV230

BV162

KFV10

WMT21

SWAI

VMF-E18

VMF-SW

VMF-SW1

VMF-E4

VMF-E4D

VMF-E5N

VMF-E5B

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

(1)

030I 040I 130I 140I 230I 240I 330I 340I

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• • • •

• •

• •

• •

• •

• •

• •

• •

• •

GAF32

GAF42

GAF62

GM22

GM32

GM42

GM62

SE20X

SE30X

SE40X

SE80X

ZX7

ZX8

Mod.VED

VCF43-4324 (2)

VCF45-4524 (2)

VCFD3-324

(2)

VCFD4-424

(2)

VCF3X4R

VCF3X4L

AMP

BC4

BC6

BC9

DSC4

GA22

GA32

GA42

GA62

GAF22

(2)(3)

(3)

(3)

(3)

030I

040I

130I

140I

230I

240I

330I

340I

• •

(4)

(4)

(4)

(4)

(1) All the Plenums ( RPA_V; PA_V; RPM_V; PM_V ) have a circular push-outs (Ø=150mm ) on both sides, which can be removed; All the Plenums can have intake/discharge either straight or downwards (straight or downwards with reference to horizontal installation).

(2) The valve kits VCF and the drain pan BC4 cannot be installed together on the same fan coil unit.

(3) The accessory DSC4 is not compatible with AMP and BC4 - BC6 - BC9.

(4) Accessories SE must be combined with the feet ZX

49

Technical data

Mod.

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

Heating capacity (70°C)

Water flow rate

Pressure drop

Heating capacity (50°C)

Water flow rate

(1) W

(1) W

(1) W

(1) l/h

(1)

(1)

(1)

(1)

(2)

VED

l/h l/h kPa kPa

(1) kPa

(2) W

(2) W

(2) W

(2) l/h l/h

Vel.

30I 030I* 40I

BV030

H 3688

M 3374

-

-

3916

3568

130I

6289

5833

130*

BV130

-

-

140I

6575

6089

230I

7160

6500

230*

BV230

-

-

240I

7909

7141

330I

10507

9343

330*

BV162

-

-

340I

10951

10017

L

H

M

L

H

M

1820

323

296

160

9

7

-

-

-

-

-

-

2366 4397

343 551

313

207

12

10

511

385

26

22

-

-

-

-

-

-

4518 5350

576 616

534

396

18

16

559

460

37

30

-

-

-

-

-

-

5800 7813

684 921

616

499

3

26

819

685

16

13

-

-

-

-

-

-

8312

960

878

729

L

H

M

L

H

M

3

2180

1990

1100

279

250

-

-

-

-

-

4

2340

2130

1410

327

296

13

3750

3480

2620

516

480

-

-

-

-

-

9

3940

3650

2710

566

525

27

4320

3920

3230

588

538

-

-

-

-

-

18

4750

4290

3450

691

624

9

6270

5580

4670

860

760

-

-

-

-

-

-

32

28

22

6550

5980

4970

922

824

Pressure drop

(2) l/h

(2) kPa

(2) kPa

L

H

M

170

8

7

-

-

-

193

12

10

(2) kPa L 3 -

HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)

5

358

27

23

13 -

-

-

-

390

19

16

9

445

35

29

20 -

-

-

-

499

31

26

13

633

16

13

9 -

-

-

-

685

21

17

13

Heating capacity (70°C)

Water flow rate

(3) W

(3) W

(3) W

(3) l/h

(3) l/h

(3) l/h

H

M

L

H

M

L

-

-

-

-

-

-

2220

2080

1590

196

183

140

-

-

-

-

-

-

-

-

-

-

-

-

3780

3596

2946

331

315

258

-

-

-

-

-

-

-

-

-

-

-

-

4493

4171

3675

394

366

322

-

-

-

-

-

-

-

-

-

-

-

-

5888

5499

4896

515

482

429

Pressure drop

(3) kPa

(3) kPa

(3) kPa

H

M

L

-

-

-

8

7

5

-

-

-

-

-

-

28

25

17

-

-

-

-

-

-

16

14

11

-

-

-

-

-

-

26

23

19

-

-

-

COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)

Total cooling capacity

(4) W

(4) W

H

M

1624

1454

1592

1416

1900

1720

2997

2790

2931

2727

3290

3050

3420

3130

3380

3080

4020

3630

5000

4420

4946

4380

5360

4790

-

-

-

-

-

-

Sensible cooling capacity

Water flow rate

Pressure drop

Air flow rate

Fans

High static pressure

Absorbed power

Max. input current

Sound power level (inlet+radiator)

Sound power level (outlet)

Water content

Coil connections

Coil connections (additiona heat exchanger)

Signal 0-10V

Power supply

(4)

(4)

(5)

W

(4) W

(4) W

(4) W l/h

(4) l/h

(4) l/h

(4) kPa

(4) kPa

(4) kPa m

3

/h m

3

/h m

3

/h type n°

Pa

Pa

Pa

W

W

W

(A)

(5) dB(A)

(5) dB(A) dB(A)

(5) dB(A)

(5) dB(A)

(5) dB(A) l

ø Gas (F)

ø Gas (F)

L 990 984 1120 2080 2029 2270 2590 2500 2900 3680 3600 3980

H 1242 1218 1350 2090 2169 2370 2700 2600 3015 3738 3670 3990

M 1116 1094 1230 1940 1900 2190 2440 2350 2718 3337,5 3280 3570

L

H

750

279

M 250

L 170

745

274

244

169

9

810 1440 1400 1610 2000 1900 2200 2800 2720 2950

327 515 504 566 588 581 691 860 851 922

296

193

14

480

358

31

469

349

31

525

390

23

538

445

44

530

430

42

624

499

37

760

633

18

753

619

18

824

685

26 H

M

L

9

7

3

H 285

7

3

280

12

5

277

27

15

433

27

15

423

20

11

420

36

25

590

35

23

582

31

16

570

14

10

805

14

9

790

21

16

775

M

L

H

M

L

H

M

L

256

161

1

61

50

250

160

1

61

50

249

160

1

61

50

397

287

2

60

50

388

280

2

60

50

386

280

2

60

50

524

417 centrifugal

2

64

50

513

412

2

64

50

509

406

2

63

50

704

572

3

66

50

695

568

3

66

50

685

563

3

64

50

H

M

L

H

M

L

21

36

29

12

21

36

29

12

21

36

29

12

26

45

33

17

26

45

33

17

26

45

33

17

0,33 0,33 0,33 0,41 0,41 0,41

54 54 54 55 55 55

52

39

52

44

52

39

53

45

53

47

53

45

32

53

40

24

0,5

57

54

44

32

53

40

24

0,5

57

54

49

32

53

40

24

0,5

57

54

44

33

86

60

35

0,5

58

55

38

33

86

60

35

0,5

58

55

38

55

38

50

48

50

48

50

48

50

48

50

48

50

48

52

49

42

49

52

49

54

51

54

51

54

51

34

1,11

40 34

1,48

39

1,5

42 39 39

1,48 1,48

44 39 34

1,48 2,52

34 34

3,4

3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"

1/2" 1/2" 1/2" 1/2" -

H 9V 9V 9V 9V 9V 9V 9V 9V 9V 9V 9V 9V

M 8,2V 8,2V 8,2V 8,2V 8,2V 8,2V 8,2V 8,2V 7,8V 7,8V 7,8V 7,8V

L 5,4V 5,4V 5,4V 5,8V 5,8V 5,8V 6,6V 6,6V 6,2V 6,2V 6,2V 6,6V

230V/1/50Hz

34

86

60

35

0,5

58

H max. speed; M med. speed; L min. speed

Heating mode

2 pipes system configuration

(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C

2 pipes system configuration (EUROVENT)

(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode

* 4 pipes system configuration with additional heat exchanger (BV)

(3)Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C

Cooling mode (EUROVENT)

(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; ΔT water 5°C

(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2

Note: For more information refer to the program selection and the technical documentation available on the website www.aermec.com

50

Dimensional data (mm)

VED: 030I - 040I - 130I - 140I - 230I - 240I - 330I - 340I

25

D

A

B

C

Asola 20x9

25

24

217

167 24

41

96

156

149

Ø20,5

Ø17,5

VED

C

D

A

B

Net weight mm mm mm mm

Kg

030I

576

550

500

530

20

040I

576

550

500

530

21

130I

807

781

731

761

23

140I

807

781

731

761

24

230I

1027

1001

951

981

29,5

240I

1027

1001

951

981

32

330I

1148

1122

1072

1102

32,5

340I

1148

1122

1072

1102

34

The technical data in this document is not binding. Aermec S.p.A. reserves the right to make any changes at any time deemed necessary for product improvement.

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italy

Telephone 0442633111 - Telefax 044293730 www.aermec.com

51

VED_I

Fan coil unit with Brushless Inverter motor (EC) for ducted systems

Cooling capacities 8÷10kW

AERMEC

partecipates in the EUROVENT programme for: FCP

Check ongoing validity of certificate online: www.eurovent-certification.com

• HORIZONTAL OR VERTICAL INSTALLATION

• VERSIONS FOR 2/4 PIPE SYSTEMS

• 1 -2 ROW HEATING ONLY COIL

• LARGE RANGE OF AVAILABLE STATIC PRESSURE

• CENTRIFUGAL FANS INVERTER

• ACCESSIBLE FAN ASSEMBLY

• AIR FILTER CLASS G3

• REVERSIBLE COIL

Unit selection

By choosing the appropriate options it is possible to select the model to suit the specific system requirements.

Configuration fields:

1 2 3

Code

Example:

1 2 3

VED

4

Size

4

5

5

Main Coil

5

3

6

Main coil only hot

6

2

7

Inverter motor

7

I

Characteristics

• Ducted air conditioning terminal unit

• Internal installation

• 3 row main coil and heating only coil accessory for 4-pipe systems

• Versions for systems with 4 pipes with main coil with 3 or 4 rows and heating only coil with 1 or 2 rows

• Reversibility of the hydraulic connection in the installation phase

• Low pressure drop in the heat exchange coils

• 3-way valves accessories

• 2-way valves accessories for systems with variable water flow rate

• Centrifugal fans with motor inverter

• Wide range of useful static pressure

Centrifugal fans in antistatic plastic. Due to their features, they allow to reduce the energy consumption with respect to normal fans

• Fans with wing-shaped profile studied to obtain high flow rate and static pressure performance and low noise emission at the same time

• Compatible with the VMF system

• Wide range of controls

• Wide range of accessories to satisfy all system requirements

• Rectangular flow flange already integrated into the framework

• Class G3 air filter with easy extraction and cleaning

• Internal insulation in Class 1 fire resistance

• IP20 protection rating

• Plastic augers, extractable for easy and efficient cleaning

• Easy installation and maintenance

• Full respect of the accident-prevention standards

52

Accessoires

Mod. VED

RDA 450 V

RDA 670 V

RPA 450 V

RPA 670 V

PA 450 V

PA 670 V

RPM 450 V

RPM 670 V

PM 450 V

PM 670 V

PMZ

KFV

VCF45C

VCF45H

VCF47C

VCF47H

VCF25C

VCF25H

VMF-E18

VMF-SW

VMF-SW1

VMF-E4

VMF-E4D

VMF-E5B

VMF-E5N

RDA_V: Straight fitting with rectangular flange for ducting.

In galvanised sheet steel

RPA_V: Intake plenum with rectangular flange for ducting.

In galvanised sheet steel

PA_V: Intake plenum with circular flanges for ducting.

In galvanised sheet steel, the flanges are in plastic

RPM_V: Flow plenum with rectangular flange for ducting.

In galvanised sheet steel, internally isolated.

PM_V: Flow plenum with circular flanges for ducting

PMZ: plenum con amortiguadores motorizados (para más detalles consulte la tarjeta dedicada).

In galvanised sheet steel, internally isolated, the flanges are in plastic

KFV: Circular flange kit for intake/flow plenum.

In plastic

VCF4_C: Kit made up from motorised

3-way valves with isolating shell, fittings and isolated copper pipes. For main coils.

230V~50 Hz power supply

VCF4_H: Kit made up from motorised

3-way valves, fittings and isolated copper pipes. For heating only coils.

230V~50 Hz power supply

VCF25C: Kit made up from motorised

2-way valves, with fittings and isolated copper pipes. For main coils. 230V~50

Hz power supply

VCF25H: Kit made up from motorised

2-way valves, with fittings and copper pipes.

For heating only coils. 230V~50 Hz power supply

WMT21: Electronic thermostat wallmount installation

SWAI: Water minimum temperature probe to use with WMT21 control panel.

VARIABLE MULTI FLOW SYSTEM

VMF System: The complete fittings of the

VMF System management system are described in the dedicated sheet.

Some VMF components require coupling with other accessories, consult the relative documentation.

530I

532I

540I

541I

730I

732I

740I

741I

53

Technical data

Mod.

VED

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

Heating capacity (70°C)

(1) W

(1) W

Water flow rate

(1) W

(1) l/h

(1) l/h

(1) l/h

Pressure drop

Heating capacity (50°C)

Water flow rate

(1) kPa

(1) kPa

(1) kPa

(2) W

(2) W

(2) W

(2) l/h

(2) l/h

Vel.

M

L

H

M

L

H

H

M

L

H

M

L

H

M

530I

17572

16467

13802

1541

1444

1211

21

18

13

10420

9780

8190

1335

1271

532I

Pressure drop

Pressure drop

(2) l/h

(2) kPa

(2) kPa

(2) kPa

(3) l/h

(3) kPa

(3) kPa

(3) kPa

L

H

M

L

L

H

M

L

COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)

(4) W H

Total cooling capacity (4) W M

1060

16

15

11

HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)

Heating capacity (70°C)

(3) W

(3) W

H

M

-

-

13540

12850

Water flow rate

(3) W

(3) l/h

(3) l/h

L

H

M

-

-

-

10720

1188

1127

-

-

-

940

22

20

14

-

-

-

-

Sensible cooling capacity

Water flow rate

(4)

(4)

(4)

(4)

W

W

W

(4) W

(4) l/h

(4) l/h

(4) l/h kPa

L

H

M

L

H

M

L

H

7760

7390

6160

6020

5710

4720

1335

1271

1060

21

7760

7390

6160

6020

5710

4720

1335

1271

1060

21

Pressure drop

Air flow rate

M

L

H

M

L

19

12

1520

1400

1120

19

12

1460

1360

1060

Fans

High static pressure

Absorbed power

Sound power level (inlet+radiator)

Sound power level (outlet)

Coil connections

Coil connections (additiona heat exchanger)

Signal 0-10V

(4) kPa

(4) kPa m3/h m3/h m3/h type n°

Pa

Pa

Pa

W

W

W

(5) dB(A)

(5) dB(A)

(5) dB(A)

(5) dB(A)

(5) dB(A)

(5) dB(A)

ø Gas (F)

ø Gas (F)

H

M

L

H

M

L

H

M

L

H

M

L

H

M

2

58

50

32

205

170

115

62

59

53

58

55

49

3/4”

-

9V

8,4V

2

56

50

32

185

163

106

3/4”

1/2”

9V

8,4V

L 6,6V 6,6V

Power supply

-

-

-

-

-

-

-

-

-

-

-

-

-

-

H max. speed; M med. speed; L min. speed

Heating mode

2 pipes system configuration

(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C

2 pipes system configuration (EUROVENT)

(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode

4 pipes system configuration (with additional heat exchanger) (EUROVENT)

(3)Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C

Cooling mode (EUROVENT)

(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; ΔT water 5°C

(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2

Note: For more information refer to the program selection and the technical documentation available on the website www.aermec.com

54

13850

12200

10400

11440

9990

8480

2382

2098

1789

58

46

35

2350

2000

1600

3

69

50

32

363

240

138

22174

19726

16728

1945

1730

1467

33

26

20

732I

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

541I

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

8850

8520

7475

776

747

656

32

30

24

56

50

32

185

163

106

8970

8540

7430

6450

6130

5040

1543

1469

1278

28

25

19

1460

1360

46

35

2410

2040

1060 centrifugal

1640

2 3

13850

12200

10400

11440

9990

8480

2382

2098

1789

58

69

50

32

370

245

140

64

66

62

64

62

3/4”

1/2”

9V

8,4V

58

3/4”

-

9V

7,6V

6,6V 6,2V

230V/1/50Hz

-

-

-

-

-

-

-

-

-

730I

38

17280

15120

12640

2382

2098

1789

57

44

33

28999

25364

21178

2544

2225

1858

67

55

49

3/4”

-

9V

8,4V

2

56

50

32

205

170

115

62

59

53

58

55

6,6V

8970

8540

7430

6450

6130

5040

1543

1469

1278

28

25

19

1500

1380

1100

-

-

-

-

-

-

-

-

-

540I

18

11820

11050

9170

1543

1469

1278

23

21

16

19908

18586

15377

1746

1630

1349

29

25

3/4”

1/2”

9V

7,6V

6,2V

58

3/4”

-

9V

7,6V

3

69

50

32

370

245

140

68

66

62

64

62

6,2V

16080

14230

11960

11320

9970

8340

2766

2448

2057

45

37

27

2350

2000

1600

-

-

-

-

-

-

-

-

-

740I

26

19150

16680

13840

2766

2448

2057

35

28

21

31706

27650

22883

2781

2425

2007

46

36

16080

14230

11960

11320

9970

8340

2766

2448

2057

45

37

27

2350

2000

1600

3

69

50

32

363

240

138

14500

13300

11830

1272

1167

1038

30

26

21

741I

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

3/4”

1/2”

9V

7,6V

6,2V

Dimensional data (mm)

VED: 530I - 532I - 540I - 541I

=

1158

1133

1053

1158

1133

1053

1109

=

10

15

300

256

45

109

241

198

275

10

15

300

256

Ø16

45

109

241

198

275

Ø16

1104

1109

VED

Weight Kg

VED: 730I - 732I - 740I - 741I

530I

42

532I

47

540I

44

541I

47

40

1558

1533

1453

10

40

15

351

307

280 316

46

109

247

287

326

Ø16

1504

1509

VED

Weight Kg

730I

58

732I

58

740I

61

741I

61

The technical data in this document is not binding. Aermec S.p.A. reserves the right to make any changes at any time deemed necessary for product improvement.

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italia

Tel. 0442633111 - Telefax 044293577 www.aermec.com

55

VEC

Cassette type fancoil Coanda-effect

Installation in false ceilingsInstallation in false ceilings

Aermec

participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com

Features

VEC: Fan coil for ambient air treatment during the summer. The air is delivered into the room via vents which, thanks to the

COANDA effect, make the air jet adhere to the ceiling.

• Installation in false ceilings

• Compatible with VMF System

• Grille with suction and adjustable delivery vents with Coanda effect (compulsory accessory).

• 3-row coil

Accessoires

• Reduced pressure drops across heat exchangers

• For systems with fixed and variable delivery

• EUROVENT certified

• 3-speed fan unit

• Quiet operation

• Motors with permanently connected condensers

• Air filter easily removed and cleaned

• Internal insulation and air filter of Class 1 fire resistance

• Removable shrouds for easy, effective cleaning

• Reversibility of the water connections during installation

• Broad range of controls and accessories

• Easy installation and maintenance

• Full compliance with safety regulations

• For possible heat mode functioning, refer to the technical manual notes.

Compulsory accessories:

the following are essential for the functioning of the units:

VEC_GL: air suction and delivery grille with adjustable Coanda-effect vents. White RAL 9010.

Accessories:

AMP: kit for wall-mounting installation.

BC5: auxiliary condensate drain tray.

BV: Single row hot water coil.

DSC4: condensate drainage device for use when natural run-off is not possible.

SIT 3-5: thermostat interface cards. These allow you to create a network of fan coils (max. 10), commanded from a centralised panel (selector or thermostat).

SIT3: commands the 3 fan speeds, and must be installed on each fan coil in the network; receives the commands from the selector or SIT5 card.

SIT5: commands the 3 fan speeds and up to 2 valves

(4-pipe systems); conveys the thermostat commands to the fan coil network.

SW3: water temperature probe, allowing the implementation of automatic season changeover for those electronic thermostats equipped with water side changeover.

SWA: SWA external probe accessory (length L = 6m).

Detects the ambient air temperature if connected to the connector (A) of the panel FMT21; in this case the ambient air temperature probe built into the panel will be automatically disabled. Detects the temperature of the water in the system to allow ventilation consent if connected to the connector (W) of the panel FMT21. Two SWA probes may be simultaneously connected to the panel FMT21.

VCF: kit consisting of a 3-way motorised valve, and copper couplings and pipes. For 3-row and 1-row coils (BV). Versions with 230V and 24V~50Hz power supply.

VCFD: Kit consisting of a 2-way motorised valve, and copper couplings and pipes. For 3-row and 1-row coils (BV). Versions with 230V and 24V~50Hz power supply.

Control panel and VMF system: the features of the control panels are described in the relevant card.

Accessoires for heating mode

RX: Armoured electric coil with safety thermostat.

(Requires a thermostat with heater management).

PXAR: Electronic thermostat with thermostated or continuous ventilation.

PCR1: Galvanised plate protection for the controls and the electrical element

BV: Single row hot water coil.

VCF: the kit contains a motorised 3-way valve with insulating shell, plus coupling and pipes in insulated copper. For

3-row.

VCFD: Kit consisting of powered 2-way valve, copper couplings and pipes. For 3 row

VEC

(Standard coil)

VEC

(increased coil)

Compulsory accessoires

VEC20GL

VEC30GL

VEC40GL

BC5

DSC4

SIT3

SIT5

(1)

SW3

SWA

VCF41

(standard coil)

VCF42

(increased coil)

VCF4124

(standard coil)

VCF4224

(increased coil)

VCFD1

(standard coil)

VCFD2

(increased coil)

VCFD124

(standard coil)

VCFD224

(increased coil)

20 30 40 50

24 34 44 54

VEC

(Standard coil)

VEC

(increased coil)

Control panel

FMT10

FMT21

KTLP

PX2

PX2C6

PX

PXAE

TPF

TF1

WMT05

WMT06

WMT10

VMF-System

VMF-E4 / E4D

VMF-E0 / E1

VMF-E5B / E5N

VMF-SW

VMF-SW1

20 30 40 50

24 34 44 54

VEC

(Standard coil)

VEC

(increased coil)

Accessoires for heating mode

RX22

RX32

(2)

(2)

RX42

RX52

(2)

(2)

PXAR

PCR1

BV122

BV132

BV142

(2)

(2)

(2)

(2)

(2)

VCF44

VCF4424

VCFD4

VCFD424

20

24

(2)(3) •

(2)(3) •

(2)(3) •

(2)(3) •

30

34

40

44

50

54

(1) DSC4 The accessory is not compatible with the BC5, and VMF system.

(2) See notes and warnings in the technical booklet

(3) only for accessory coil BV 1R

56

Technical data

Mod. VEC

COOLING PERFORMANCE

Total cooling capacity

Sensible cooling capacity

Water flow rate

Pressure drop

Air flow rate

Fans

Absorbed power

Max. input current

Sound power level

Sound pressure level

Water content

Coil connections

Speed connected

Power supply

(2)

(2)

(2)

(3)

(3)

(3)

A dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)

W

W

W m 3 /h type n°

(1) W

(1) W

(1) W

(1) W

(1) W

(1) W

(1) l/h

(1) l/h

(1) l/h

(1) kPa

(1) kPa

(1) kPa m 3 /h m

3

/h l

ø

Vel.

H

M

L

H

M

L

H

M

L

H

M

L

L

H

M

L

H

M

L

H

M

H

M

L

H

M

L

20

1320

1080

800

1080

880

640

227

186

138

5

4

2

247

167

130

1

25

22

19

0,12

48

42

35

39,5

33,5

26,5

0,79

1/2"G

V3

V2

V1

24

1522

1076

877

1147

800

667

262

185

151

3

2

1

247

167

130

1

25

22

19

0,12

48

42

35

39,5

33,5

26,5

0,79

1/2"G

V3

V2

V1

30

1950

1640

1370

1530

1280

1050

335

282

236

13

11

6

383

309

241

0,21

49

43

37

2

44

33

25

40,5

34,5

28,5

1,11

1/2"G

V3

V2

V1

34

2471

2140

1789

1775

1510

1257

425

368

308

8

6

5

383

309

241 centrifugal

2

44

33

25

0,21

49

43

37

40,5

34,5

28,5

1,11

1/2"G

V3

V2

V1

230V/1/50Hz

40

2980

2470

1980

2410

1980

1580

513

425

341

11

9

6

511

406

306

0,28

48

43

38

2

57

43

30

39,5

34,5

29,5

1,48

3/4"G

V3

V2

V1

44

3907

3335

2552

2737

2421

1909

672

574

439

22

17

10

511

406

306

2

57

43

30

0,28

48

43

38

39,5

34,5

29,5

1,48

3/4"G

V3

V2

V1

50

H max. speed; M med. speed; L min. speed

Cooling mode (VEC 20 - 30 - 40 - 50 EUROVENT)

(1) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C

(2) Sound power level on the basis of measurements made in compliance with Eurovent 8/2

(3) Sound pressure level (A-weighted) measured in the room with volume V=85m 3 , reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m

Heating

See notes and warnings in the technical booklet.

Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

Dimensions (mm)

VEC_GL (Compulsory accessory)

VEC20GL

VEC30GL

VEC40GL

3610

3170

2350

2590

2270

1680

621

545

404

15

10

6

613

529

371

2

67

46

34

0,35

53

50

43

44,5

41,5

34,5

1,48

3/4"G

V3

V2

V1

54

4282

4000

2995

2909

2437

1785

737

688

515

30

27

16

613

529

371

0,35

53

50

43

2

67

46

34

44,5

41,5

34,5

1,48

3/4"G

V3

V2

V1

Ø262

B

E

595

C

D

15

A

A

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

895 1195

Dimensions VEC + VEC_GL (maximum dimensions)

Mod.

Height

Widht

Depth

Weight (VEC)

Weight (VEC_GL)

VEC

VEC

(A) mm

(B) mm

(C) mm kg kg

20/24

20GL

283

595

595

15,5

3,7

30/34

30GL

283

895

595

20,6

5,7

Dimensions VEC + VEC_GL (Dimensions for installation)

Mod.

Height

Widht

Depth

VEC

VEC

(A) mm

(D) mm

(E) mm

20/24

20GL

283

574

574

30/34

30GL

283

574

874

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italy

Tel. 0442633111 - Telefax 044293577 www.aermec.com

40/44

40GL

283

1195

595

24,7

7

40/44

40GL

283

574

1174

50/54

40GL

283

1195

595

24,7

7

50/54

40GL

283

574

174

57

VEC_I

Cassette type fancoil Coanda-effect, with Brushless Inverter motor (EC)

Installation in false ceilings

Aermec

participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com

Features

VEC_I: Fan coil for ambient air treatment during the summer. The air is delivered into the room via vents which, thanks to the

COANDA effect, make the air jet adhere to the ceiling.

• Installation in false ceilings

• Compatible with VMF System

• Grille with suction and adjustable delivery vents with Coanda effect (compulsory accessory).

• Unit with standard coil (20

÷50)

• Unit with increased coil (24 ÷54)

• Reduced pressure drops across heat exchangers

• For systems with fixed and variable delivery

• Fan unit with Brushless motor (continuous

0-100% speed variation)

• Quiet operation

• Air filter easily removed and cleaned

• Internal insulation and air filter of Class 1 fire resistance

• Reversibility of the water connections during installation

• Broad range of controls and accessories

• Easy installation and maintenance

• Full compliance with safety regulations

• For possible heat mode functioning, refer to the technical manual notes.

Accessori

Compulsory accessories:

the following are essential for the functioning of the units:

VEC_GL: air suction and delivery grille with adjustable Coanda-effect vents.

White RAL 9010.

Accessories:

BC5: auxiliary condensate drain tray.

BV: Single row hot water coil.

DSC4: condensate drainage device for use when natural run-off is not possible.

VCF: kit consisting of a 3-way motorised valve, and copper couplings and pipes. For

3-row and 1-row coils (BV). Versions with

230V and 24V~50Hz power supply.

VCFD: Kit consisting of a 2-way motorised valve, and copper couplings and pipes. For

3-row and 1-row coils (BV). Versions with

230V and 24V~50Hz power supply.

Control panel and VMF System: the characteristics are described on the appropriate card.

Accessories for heating mode

BV: Single row hot water coil.

VCF: the kit contains a motorised 3-way valve with insulating shell, plus coupling and pipes in insulated copper Versions with 230V and 24V~50Hz power supply.

VCFD: Kit consisting of powered 2-way valve, copper couplings and pipes. For 3 row. Versions with 230V and 24V~50Hz power supply.

VEC_I

(standard coil)

VEC_I

(increased coil)

Compulsory accessories

VEC20GL

VEC30GL

VEC40GL

BC5

DSC4

VCF41

(standard coil)

VCF42

(increased coil)

(1)

VCF4124

(standard coil)

VCF4224

(increased coil)

20 30 40 50

24 34 44 54

VEC_I

(standard coil)

VEC_I

(increased coil)

VCFD1

(standard coil)

VCFD2

(increased coil)

VCFD124

(standard coil)

VCFD224

(increased coil)

Control panel

WMT20

VMF-System

VMF-E4 / E4D

VMF-E18

VMF-E5B / E5N

20 30 40 50

24 34 44 54

VEC_I

(standard coil)

VEC_I

(increased coil)

VMF-SW

VMF-SW1

20 30 40 50

24 34 44 54

Accessory dedicated to heating mode

BV122

BV132

(2)

(2)

BV142

(2)

VCF44

VCF4424

VCFD4

VCFD424

(2)(3)

(2)(3)

(2)(3)

(2)(3)

(1) DSC4 The accessory is not compatible with the basins BC5, and VMF system.

(2)

See notes and warnings in the technical booklet.

(3) only for accessory coil BV 1R

58

Technical data

Mod. VEC_I

COOLING PERFORMANCE

Total cooling capacity

Sensible cooling capacity

Water flow rate

Pressure drop

Air flow rate

Fans

Absorbed power

Max. input current

Sound power level

Sound pressure level

Water content

Coil connections

Speed connected

(2)

(2)

(2)

(3)

(3)

(3)

(1) W

(1) W

(1) W

(1) W

(1) W

(1) W

(1) l/h

(1) l/h

(1) l/h

(1) kPa

(1) kPa

(1) kPa m 3 /h m

3

/h m 3 /h type n°

W

W

W

A dB(A) dB(A) dB(A) dB(A) dB(A) l dB(A)

ø

Vel.

H

M

L

H

M

L

H

M

L

H

M

L

L

H

M

L

H

M

L

H

M

H

M

L

H

M

L

20I

1320

1080

800

1080

880

640

227

186

138

4,6

4

2

247

194

130

1

12

8

5

0,11

48

42

35

39,5

33,5

26,5

0,79

1/2"G

5,4V

4,2V

2,6V

24I

1522

1224

877

1147

908

667

262

211

151

3

2

1

247

194

130

1

12

8

5

0,11

48

42

35

39,5

33,5

26,5

0,79

1/2"G

5,4V

4,2V

2,6V

30I

1950

1640

1370

1530

1280

1050

335

282

236

13,3

11

6

383

309

241

2

10

10

10

0,11

49

43

37

40,5

34,5

28,5

1,11

1/2"G

5V

3,8V

2,8V

34I

10

10

10

0,11

49

43

37

40,5

34,5

308

8

6

4

383

309

241 centrifugal

2

2471

2140

1789

1775

1510

1257

425

368

28,5

1,11

1/2"G

5V

3,8V

2,8V

230V/1/50Hz

40I

2980

2470

1980

2410

1980

1580

513

425

341

11,3

9

6

511

406

306

2

17

9

6

0,14

48

43

38

39,5

34,5

29,5

1,48

3/4"G

5,1V

3,9V

2,8V

44I

3907

3335

2552

2737

2421

1909

672

574

439

22

16

9

511

406

306

2

17

9

6

0,14

48

43

38

39,5

34,5

29,5

1,48

3/4"G

5,1V

3,9V

2,8V

50I

Power supply

H max. speed; M med. speed; L min. speed

Cooling mode (VEC 20I - 30I - 40I - 50I EUROVENT)

(1) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C

(2) Sound power level on the basis of measurements made in compliance with Eurovent 8/2

(3) Sound pressure level (A-weighted) measured in the room with volume V=85m

3

, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m

Heating

See notes and warnings in the technical booklet.

Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

Dimensions (mm)

VEC_GL (Compulsory accessory)

3610

3170

2350

2590

2270

1680

621

545

404

14,8

10

6

613

529

371

2

37

20

8

0,3

53

50

43

44,5

41,5

34,5

1,48

3/4"G

6,1V

5,1V

3,4V

VEC20GL

VEC30GL

VEC40GL

54I

4282

4154

2995

2909

2437

1785

737

714

515

30

28

18

613

529

371

2

37

20

8

0,3

53

50

43

44,5

41,5

34,5

1,48

3/4"G

6,1V

5,1V

3,4V

Ø262

B

E

595

C

D

15

A

A

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

895 1195

Dimensions VEC_I + VEC_GL (maximum dimensions)

Mod.

Height

Widht

Depth

Weight (VEC_I)

Weight (VEC_GL)

VEC_I

20/24

VEC

20GL

(A) mm

(B) mm

(C) mm kg kg

283

595

595

15,5

3,7

30/34

30GL

283

895

595

20,6

5,7

Dimensions VEC_I + VEC_GL (Dimensions for installation)

40/44

40GL

283

1195

595

24,7

7

Mod.

Height

Widht

Depth

VEC_I

20/24

VEC

20GL

(A) mm 283

(D) mm

(E) mm

574

574

30/34

30GL

283

574

874

40/44

40GL

283

574

1174

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italia

Tel. 0442633111 - Telefax 044293577 www.aermec.com

50/54

40GL

283

1195

595

24,7

7

50/54

40GL

283

574

174

59

FCL

Cassette type fancoil

Ceiling and false ceiling installation, cooling power from 1900 up to 11000W

Models:

FCL 32 , FCL36 , FCL42 , FCL62 - FCL72

FCL 34 , FCL38 , FCL44 , FCL64

Models:

FCL 82 , FCL102 , FCL122

FCL 84 , FCL104 , FCL124

FCL with accessory FCLMC

Aermec

participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.

com

GLL10 - GLL10M - GLL10R - GLL10N

White: RAL 9010

GLL20 - GLL20R - GLL20N

White: RAL 9010

FCLMC

White: RAL 9010

Remote Control included for GLL10M

GLL10R - GLL20R

• 4 CONFIGURATIONS ON ONE CASSETTE-TYPE FAN COIL:

- WITH MOTORISED LOUVERS THAT CAN BE ORIENTED VIA THE REMOTE CONTROL

(GLL10M ONLY)

- WITH LOUVERS THAT CAN BE ORIENTED MANUALLY, REMOTE CONTROL

- WITH MANUALLY ADJUSTABLE FINS, VMF SYSTEM ELECTRONIC THERMOSTAT,

WALL-MOUNTED CONTROL PANEL (VMF-E4), COMPLETE INTEGRATION WITH THE

VMF SYSTEM (ONLY WITH GLL10N AND GLL20N)

• STANDARD INTERNAL 3-WAY VALVE, WITH FAST CONNECTION ACTUATOR AND

VISUAL POSITION SIGNALLING

• VERSION WITH 2-WAY VALVE FOR VARIABLE WATER FLOW RATE SYSTEMS

• VERSION WITHOUT VALVES

• HEAT EXCHANGE COIL WITH SHAPED PROFILE AND ENHANCED SURFACE

• FAN PURPOSELY DESIGNED FOR LOW SOUND EMISSIONS

• VERSIONS FOR 2-PIPE AND 4-PIPE SYSTEMS

• ALSO AVAILABLE WITH ELECTRIC HEATER FOR HEATING

Features

• 8 sizes for 2-pipe versions:

FCL 32-36-42-62-72-82-102-122

• 7 sizes for 4-pipe versions:

FCL 34-38-44-64-84-104-124

• Standard preparation with standard internal three-way valve, with fast connection actuator and position visual signalling.

• FCL_V2 preparation (available upon request), with internal two-way valve, suitable for variable water flow rate systems.

• FCL_VL preparation (available upon request), without internal valve.

• 3 configurations on one cassette-type fan coil:

- louvers that can be oriented by means of a remote control and electronic control if coupled with the accessory GLL10M;

- with remote control, louvers that can be oriented manually and by means of electronic control if coupled with the accessory

GLL10R or GLL20R;

- with louvers that can be oriented manually if coupled with the accessory GLL10 or

GLL20, also requires a wired control panel

(accessory).

• High design aesthetics.

• Grille dimensions perfectly integrable in stand a r d s u s p e n d e d c e i l i n g p a n e l s o f

600x600mm and 840x840mm for the most powerful units.

• Fan designed for low sound emissions.

• 3-speed and 4-speed mixed flow (axial + centrifugal) fan unit for larger sizes (FCL

42-44-62-64-72-82-84-102-104-122-124), in order to select the 3 speeds that best meet delivered power and quiet operation requirements.

• The load-bearing structure, reinforced with a galvanised steel side band, contains insulation elements in expanded polystyrene obtained from injection moulding for purposes of noise reduction and air routing (FCL 42-44-

62-72-64).

• Structure made entirely of galvanised steel, containing insulation elements in closed cell expanded polystyrene and externally covered with anti-condensate felt (FCL 82-84-102-

104-122-124).

• Condensation drip tray in one piece, with V0 self-extinguishing level and overmoulding to insulation in expanded polystyrene with flame retardant additive.

• Heat exchanger with shaped profile to increase the exchange surface, and easily accessible drain valves.

• Continuous fan operation to prevent stratification of room air.

• Possibility of direct release of external air regardless of indoor unit ventilation.

• Possibility to control the climate of adjacent rooms as well. The versions FCL 82-84-102-

104-122-124 allow 3-direction delivery.

• Air filter easily removed and cleaned, selfsupporting structure, characterised by a high efficiency and low pressure drops, with class-

V0 fire resistance (UL 94).

• Electrostatically pre-charged air filter regenerated with fire resistance class 2 (UL 900),

(FEL 10 accessory for GLL10, GLL10R,

GLL10M).

• Full compliance with safety regulations.

• Easy installation and maintenance.

60

Accessories

Compulsary GLL accessories,

essential for unit operation:

GLL10M (600x600)

Delivery grille with adjustable louvers by means of a remote control and air intake, supplied with an infrared receiver with emergency operation switch.

White RAL 9010.

GLL10R (600x600)

GLL20R (840x840)

Delivery grille with louvers manually adjustable and air intake. With remote control, supplied with an infrared receiver with emergency operation switch. White RAL 9010.

GLL10 (600x600)

GLL20 (840x840)

Delivery grille with louvers manually adjustable and air intake. Combined with wallmounted control panel. White RAL 9010.

GLL10N (600x600)

GLL20N (840x840)

Delivery grille with Manually adjustable fins and air intake, with "VMF System" advanced electronic thermostat. Individual units, or network master also requires a wired control panel (VMF-E4 compulsory accessory). White

RAL 9010.

Control panels and VMF System: the characteristics are described on the appropriate card.

Accessories:

FCLMC10

FCLMC20

is a perimeter case in galvanised and painted sheet steel, which is used when the fan coil is installed outside the suspended ceiling. It is used for aesthetics and protection, therefore the technical features of the FCL and FCLI remain unvaried.

FEL10 : kit n°5 electrostatically pre-charged air filter, with fire resistance class 2 (UL 900).

KFL : Delivery flange, allowing the air to be directed to an adjacent room.

KFL20 (***) : delivery flange, allowing the air to be directed to an adjacent room. Up to three KFL20 can be assembled on a single unit.

KFLD : suction flange, allows to introduce external air directly into the room without mixing.

KFLD20 (***) : suction flange, allows to introduce external air directly into the room without mixing. Up to two KFL20D can be assembled on a single unit.

RXLE - RXLE20 : electric heater for heating, can be installed on the single-fan FCL units.

Requires GLL-M or GLL-R.

SIT 3-5 : Thermostat Interface Cards. They allow the creation of a network of fan coils

(max. 6) commanded by a central control panel (selector or thermostat).

SIT3 : commands the 3 fan speeds and must be installed on each fan coil of the network; receives the commands from the selector or the SIT5 card.

SIT5: commands the 3 fan speeds and up to 2 valves (four pipes systems); transmits the thermostat commands to the network of fan coils fitted with SIT3.

SW3 : Minimum water temperature probe, to be used with electronic PXAE thermostats.

SW4 : Minimum water temperature probe, to be used with the units fitted with a grille with remote control. Conpulsury with GLL_M,

GLL_R, GLL_N

SWA : External SWA probe accessory for

FMT21 panels. Detects the ambient air temperature if connected to the connector (A); the probe in the panel will be automatically disabled. Detects the temperature of the water in the system, for ventilation consent, if connected to the connector (W) (Length L = 6m)

VHL1 - VHL20 : motor-driven three-way valve for the heating battery in 4-pipe systems.

Obligatory accessory in 4-pipe systems.

VHL2 - VHL22 : motor-driven two-way valve for the heating battery in 4-pipe systems.

Obligatory accessory in 4-pipe systems with variable flow rates.

(2)

(2)

(1)

(1)

(3)

(1)

(3)

(1)

(1)

(1)

(1)

(1)

(3)

(3)

(3)

(3)

(3)

(3)(4)

(3)

(3)

(3)

(5)

-

-

-

-

-

-

-

-

-

-

32

-

SW3

SW4

SWA

VHL1

VHL20

VHL2

VHL22

SIT 3

SIT 5

FMT10

FMT21

PX

PX2- PX2C6

PXAE

TPF

WMT10

VMF-E4 / E4D

Mod. FCL

GLL10

GLL10M

GLL10R

GLL10N

GLL20

GLL20R

GLL20N

FCLMC10

FCLMC20

FEL10

KFL

KFL20

KFLD

KFLD20

RXLE

RXLE20

-

-

-

-

-

-

-

-

-

64

-

-

-

-

-

-

-

-

-

-

-

62

-

-

-

-

-

-

-

-

-

-

44

-

-

-

-

-

-

-

-

-

-

-

42

-

-

-

-

-

-

-

-

-

-

38

-

-

-

-

-

-

-

-

-

-

-

36

-

-

-

-

-

-

-

-

-

-

34

-

(1) Compulsory with GLL_M, GLL_R, GLL_N

(2) A maximum of three KFL20 / KFL20D can be assembled on a single unit

(3) Accessories that can only be used in combination with GLL10 and GLL20 grilles

.

(4) PX2C6 = Multiple package of n°6 “PX2” control panels

(5) Accessories that can only be used in combination with the GLL10N and GLL20N grilles for individual units or network master

-

-

-

-

-

-

-

-

-

-

72

-

-

-

-

-

-

-

-

-

-

82

-

-

-

-

-

-

-

-

-

-

-

84

-

-

-

-

-

-

-

-

-

-

-

-

-

102

-

-

-

-

-

-

-

-

-

-

-

104

-

-

-

-

-

-

-

-

-

-

-

-

-

122

-

-

-

-

-

-

-

-

-

-

-

124

-

-

-

-

61

Technical data

Mod.

Heating capacity (70°C)

(1)

(1)

(1)

(2)

(2)

(2)

(2)

(2)

(1)

(1)

(1)

(1)

(1)

FCL

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

(1) W kPa kPa kPa

W

W

W l/h l/h

W

W l/h l/h l/h

Vel.

32

H

3995

M 2946

L

2221

34

-

-

36

6270

4503

38

-

-

42

7335

4473

44

-

-

62

10487

6373

64

-

-

72 82

11321 11877

7571 8118

84

-

-

102

17727

11714

104

-

-

122

21747

14729

124

-

-

Water flow rate

Pressure drop

Heating capacity (50°C)

Water flow rate

Pressure drop

Power supply

(2)

(2)

(2)

(2) l/h kPa kPa kPa

M

L

L

H

H

M

L

H

M

L

H

H

M

350

258

195

10

6

4

2380

M 1760

L

1330

327

253

200

9

6

4

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

3423

550

395

300

19

10

6

3750

2690

2050

516

387

308

14

8

5

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

3319

643

392

291

24

10

6

4400

2690

2000

679

437

337

23

10

6

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

5192

920

559

455

42

17

12

6250

3830

3100

857

552

458

32

15

10

V1

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

V1

6143 5875

993

664

539

42

20

14

1042

712

515

26

13

7

6750 7100

230V/1/50Hz

4490 4850

3650 3500

939

576

482

38

16

11

V1

1032

697

482

23

11

6

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

8295

1555

1028

728

25

12

6

10600

7000

4950

1548

1015

697

25

12

6

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

10531

1908

1292

924

42

21

11

13000

8800

6300

1892

1290

922

34

17

9

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)

(3) W H 2600 -

Heating capacity (70°C) 2190 -

2600

2190 (3)

(3)

(3)

W

W l/h

M

L

H

-

1950

228 -

1950

228

Water flow rate

Pressure drop

(3)

(3)

(3)

(3) l/h l/h kPa kPa

M

L

H

M

-

-

-

-

192

171

11

8

-

-

-

-

192

171

11

8

-

-

-

-

-

-

-

2730

2290

1960

240

201

172

12

8

-

-

-

-

-

-

-

3570

2810

2480

313

247

218

22

15

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

8500

6400

5300

746

561

465

14

9

-

-

-

-

-

-

-

10000

7300

5900

877

640

518

19

11

-

-

-

-

-

-

-

12500

9300

7050

1097

816

618

29

17

(3) kPa L 6 6 6 12 6 7 10

COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)

(4) W H 1900 1900 3000 2770 3950 3000 4980 4610 5460 6000 6000 9000 7200 11000 8800

Total cooling capacity (4)

(4)

(4)

W

W

W

L

H

M 1470 1470 2250 2080 2540 2340 3210 2970 3350 4050 4050 5900 4920 7500 6220

1160 1160 1790 1650 1960 1810 2660 2460 2800 2800 2800 4050 3500 5360 4570

1520 1520 2400 2240 3160 2180 3810 3530 4100 4200 4200 6660 5300 8470 6770

Sensible cooling capacity

Water flow rate

Pressure drop

Air flow rate

Fans

Absorbed power

Max. input current

Sound power level

Sound pressure level

(4)

(4)

(4)

(4)

(4)

(4)

(4)

(4)

W

W l/h l/h l/h kPa kPa kPa m m m type n°

230V W

230V W

230V W

(6)

(6)

(6)

3

3

3

/h

/h

/h

230V A

(5) dB(A)

(5)

(5) dB(A) dB(A) dB(A) dB(A) dB(A)

H

M

L

H

M

L

M

L

L

H

H

M

M

1250 1250 1780 1660 1820 1680 2270 2100 2350 2770 2770 4300 3530 5730 4670

L 990 990 1390 1300 1380 1270 1860 1720 1890 1900 1900 2940 2480 4040 3370

327 327 516 476 679 516 857 793 939 1032 1032 1548 1238 1892 1514

253 253 387 358 437 402 552 511 576 697 697 1015 846 1290 1070

200 200 308 284 337 311 458 423 482 482 482 697 602 922 786

10

7

4

600

10

7

4

600

15

9

6

600

13

8

5

600

25

11

7

700

15

10

6

700

36

16

12

880

35

16

11

880

43

18

13

900

25

12

6

1100

25

12

6

1100

28

13

7

1350

26

13

7

1350

38

19

10

1750

38

22

10

1750

410

300

410

300

410

300

410

300

360

260

360

260

500

380

500

380

520

400

680

460

680

460

830

560

830

560

1100

750

1100

750

H

M

L

H

M

L

1

45

31

21

0,22

46

38

35

37

29

26

1

45

31

21

0,22

46

38

35

37

29

26

1

45

31

21

0,22

46

38

35

37

29

26

1

45

31

21

0,22

46

38

35

37

29

26

1

75

32

22

0,33

53

38

35

44

29

26

1

47

32

22

0,33

46

38

35

37

29

26

1

83

37

26

0,37

61

47

41

52

38

32 centrifugal

1

101

45

32

0,45

61

47

41

52

38

32

1

110

58

50

0,52

60

49

43

51

40

34

1

150

80

45

0,7

50

43

39

41

34

30

1

150

80

45

0,7

50

43

39

41

34

30

1

155

80

50

0,7

54

45

40

45

36

31

1

155

80

50

0,7

54

45

40

45

36

31

1

175

105

55

0,75

60

50

44

51

41

35

1

175

105

55

0,75

60

50

46

51

41

37

Water content

Water content (additiona heat exchanger)

Coil connections

Coil connections (additiona heat exchanger)

ø

ø l l

1,2

-

3/4"

-

1,2

0,3

3/4"

1/2"

1,5

-

3/4"

-

1,5

0,5

3/4"

1/2"

1,5

-

3/4"

-

1,5

0,5

3/4"

1/2"

2,1

-

3/4"

-

2,1

0,6

3/4"

1/2"

2,1

-

3/4"

-

3,0

-

3/4"

-

3,0

1,5

3/4"

1/2"

4,5

-

3/4"

-

4,5

1,5

3/4"

1/2"

4,5

-

3/4"

-

4,5

1,5

3/4"

1/2"

Speed connected

H

M

V3

V2

V3

V2

V3

V2

V3

V2

V4

V2

V4

V2

V4

V2

V4

V2

V4

V2

V4

V2

V4

V2

V4

V2

V4

V2

V4

V2

V4

V2

L V1 V1 V1 V1 V1 V1 V1 V1 V1 V1 V1 V1

H max. speed; M med. speed; L min. speed

Heating mode

2 pipes system configuration

(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C

2 pipes system configuration (EUROVENT)

(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode

4 pipes system configuration (with additional heat exchanger) (EUROVENT)

(3)Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C

Cooling mode (EUROVENT)

(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C

(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2

(6) Sound pressure level (A-weighted) measured in the room with volume V=100m

3

, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m

Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

62

Dimensions (mm)

FCL 32 - 34 - 36 - 38 - 42 - 44 - 62 - 64 - 72

FCL 32 V2 - 34 V2 - 36 V2 - 38 V2 - 42 V2 - 44 V2 - 62 V2 - 64 V2 - 72 V2

FCL 32 VL - 34 VL - 36 VL - 38 VL - 42 VL - 44 VL - 62 VL - 64 VL - 72 VL

Mod. FCL

Weight

Mod. FCL

Wheigt

Mod. FCL

Weight kg kg

32

20,5

32 V2

20,5

32 VL

20

34

21

34 V2

21

34 VL

20,5 kg

FCL 82 - 84 - 102 - 104 - 122 - 124

FCL 82 V2 - 84 V2 - 102 V2 - 104 V2 - 122 V2 - 124 V2

FCL 82 VL - 84 VL - 102 VL - 104 VL - 122 VL - 124 VL

36

20,5

36 V2

20,5

36 VL

20

38

21

38 V2

21

38 VL

20,5

42

20,5

42 V2

20,5

42 VL

20

44

21

44 V2

21

44 VL

20,5

62

22

62 V2

21

62 VL

21,5

64

22,5

64 V2

22,5

64 VL

22

72

22,5

72 V2

22,5

72 VL

22

GLL20N

GLL20N

Mod. FCL

Weight

Mod. FCL

Weight kg

82

35

82 V2

35

84

36

84 V2

36

102

36

102 V2

36 kg

Mod. FCL

Weight kg

All specifications are subject to change without prior notice.

Although every effort has been made to ensure accuracy, Aermec does not assume responsibility or liability for eventual errors or omissions

32 VL

34

34 VL

35

102 VL

35

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italy

Tel. 0442633111 - Telefax 044293577 www.aermec.com

104

36

104 V2

36

104 VL

35

122

36

122 V2

36

122 VL

35

124

36

124 V2

36

124 VL

35

63

FCLI

Cassette-type fancoils with Brushless Inverter motor (EC)

Continuous 0-100% air flow rate regulation

Ceiling and false ceiling installation, cooling power from 1900 up to 11000W

Models:

FCLI32 , FCLI42 , FCLI62

FCLI34 , FCLI44 , FCLI64

Models:

FCLI82 , FCLI122 , FCLI124

FCLI with accessory FCLMC

Aermec

participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com

GLLI10 - GLLI10N

White: RAL 9010

GLLI20 - GLLI20N

White: RAL 9010

FCLMC

White: RAL 9010

• ENERGY SAVINGS OF 50% COMPARED WITH A FAN

COIL WITH TRADITIONAL 3-SPEED MOTOR

• VERY QUIET OPERATION

• TOTAL COMFORT: REDUCED TEMPERATURE AND

HUMIDITY VARIATIONS IN THE AIR-CONDITIONED

ROOMS

STANDARD INTERNAL THREE-WAY VALVE, WITH FAST

CONNECTION ACTUATOR AND POSITION VISUAL

SIGNALLING

VERSION WITH 2-WAY VALVE FOR VARIABLE WATER

FLOW RATE SYSTEMS

VERSION WITHOUT VALVES

Features

• Fan unit with Brushless motor (Continuous

0-100% speed variation);

• 5 sizes for 2-pipe versions:

FCLI 32-42-62-82-122

• 4 sizes for 4-pipe versions:

FCLI 34-44-64-124

• Standard preparation with standard internal three-way valve, with fast connection actuator and visual signalling of the position

• FCLI_V2 preparation (available upon request), with internal two-way valve, suitable for variable water flow rate systems

• FCLI_VL preparation (available upon request), without internal valve

• Requires matching with the obligatory accessories, grill and control panel, necessary for the operation

• High design aesthetics

• Grille dimensions that can be perfectly incorporated into standard suspended ceiling panel sizes (600x600 mm) and (840X840) for more powerful units.

• Fan for low sound emissions

• EUROVENT certification

• The load-bearing structure, reinforced with a galvanised steel side band, contains insulation elements in expanded polystyrene obtained from injection moulding for purposes of noise reduction and air routing

• The condensation drip tray is in one piece, with V0 self-extinguishing level and joined by means of over-moulding technology to the insulation in expanded polystyrene with flame retardant additive

• Heat exchanger with shaped profile to increase the exchange surface, and easily accessible drain valves

• Possibility of direct release of external air regardless of indoor unit ventilation

• Air filter easily removed and cleaned, selfsupporting structure, characterised by a high efficiency and low pressure drops, with a fire resistance class V0 (UL 94)

• Electrostatically pre-charged air filter regenerated with fire resistance class 2 (UL 900), (FEL

10 accessory)

• Full compliance with the accident prevention standards

• Ease of installation and maintenance

64

Accessories

Obligatory accessories, essential for unit operation:

GLLI10 (600x600)

GLLI20 (840x840)

Delivery grille with louvers manually adjustable and air intake. Combined with wallmounted control panel. White RAL 9010.

WMT20 : Control panel with electronic thermostat and LCD monitor. Wall mounting.

SWI : Water temperature probe for WMT20 control panels. Cable length L = 2m.

GLLI10N (600x600)

GLLI20N (840x840)

Delivery grille without water probe, with

Manually adjustable fins and air intake, with

"VMF System" advanced electronic thermostat.

Individual units, or network master also requires a wired control panel (VMF-E4 compulsory accessory). White RAL 9010.

VMF-E4 : Control panel “VMF System” with electronic thermostat and LCD monitor. Wallmounting

SW4 : Water temperature probe for the control of maximum / minimum temperature (2-pipe system) or for the control of minimum temperature in the heating coil (4-pipe system)

VMF-SW1 : Water temperature probe for the control of maximum temperature in the cooling coil (4-pipe system)

Control panels and VMF System: the characteristics are described on the appropriate card.

Accessories:

FCLMC10

FCLMC20 : is a perimeter case in galvanised and painted sheet steel, which is used when the fan coil is installed outside the suspended ceiling. It is used for aesthetics and protection, therefore the technical features of the

FCL and FCLI remain unvaried. FCLMC20 requires the combination with the

FCLMC20IK accessory.

FCLMC20IK : Installation kit for Controller

Inverter, compulsory for units with FCLM20.

FEL10 : electrostatically pre-charged air filter, regenerated with fire resistance class 2 (UL 900).

KFL10

KFL20 : Delivery flange, allowing the air to be directed to an adjacent room.

KFLD

KFLD20 : suction flange, allows to introduce external air directly into the room without mixing.

VHL1 : motor-driven three-way valve for the heating battery in 4-pipe systems. Obligatory accessory in the 4-pipe systems.

VHL2 : motor-driven two-way valve for the heating battery in 4-pipe systems. Obligatory accessory for 4-pipe systems with variable flow rates.

Mod. FCLI

GLLI10

GLLI20

WMT20

GLLI10N

GLLI20N

VMF-E4 *

FCLMC10

FCLMC20 **

FCLMC20IK **

FEL10

KFL

KFL20

KFLD

KFLD20

VHL1

VHL2

SWI

SW4 *

VMF-SW1 *

32

34

42

Compatibility of accessories

44

* Accessory for GLLI_N

** FCLMC20 requires the combination with the FCLMC20IK accessory

62

64

82

122

124

65

Technical data

Mod.

FCLI Vel.

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

(1) W H

Heating capacity (70°C)

Water flow rate

Pressure drop

Heating capacity (50°C)

Water flow rate

Pressure drop

(1)

(1)

(1)

(1)

(2)

(1)

(1)

(1)

(1)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(2) l/h kPa kPa kPa

W

W

W l/h l/h

W

W l/h l/h l/h kPa kPa kPa

M

L

H

L

H

M

L

H

M

M

L

H

M

M

L

L

H

32 34

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

1760

1330

327

253

200

9

6

4

3995

2946

2221

350

258

195

10

6

4

2380

HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)

(3) W H 2600

Heating capacity (70°C) (3) W M 2190

Water flow rate

(3)

(3)

(3)

W l/h l/h

L

H

M -

-

1950

228

192

Pressure drop

(3)

(3)

(3) l/h kPa kPa

L

H

M

(3) kPa L

COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)

Total cooling capacity

(4)

(4)

W

W

H

M

-

-

-

171

11

8

6

Sensible cooling capacity

Water flow rate

(4)

(4)

(4)

(4)

(4)

(4)

W

W

W

W l/h l/h

L

H

M

L

H

M

1900

1470

1160

1520

1250

990

327

253

1900

1470

1160

1520

1250

990

327

253

Pressure drop

Air flow rate

Fans

Absorbed power

Max. input current

Sound power level

Sound pressure level

Water content

Water content (additiona heat exchanger)

Coil connections

Coil connections (additiona heat exchanger)

Percentage of work than the signal configuration

(4)

(4)

(4)

(4)

(5)

(5)

(5)

(6)

(6)

(6) l/h kPa kPa kPa m 3 /h m 3 /h m

3

/h type

ø

ø

% l l dB(A) dB(A) n°

W

W

W

(A) dB(A) dB(A) dB(A) dB(A)

%

%

M

L

L

H

L

H

M

H

M

L

H

M

L

H

M

L

H

M

L

29

26

1,2

-

3/4"

-

90

46

38

35

37

1

18

13

10

0,28

200

10

7

4

600

410

300

62

42

29

26

1,2

0,3

3/4"

1/2"

90

46

38

35

37

1

18

13

10

0,28

200

10

7

4

600

410

300

62

42

Power supply

42

4850

3500

1032

697

482

23

11

6

11877

8118

5875

1042

712

515

26

13

7

7100

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

3830

3100

857

552

458

32

15

10

10487

6373

5192

920

559

455

42

17

12

6250

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2690

2000

679

437

337

23

10

6

7335

4473

3319

643

392

291

24

10

6

4400

29

26

1,5

-

3/4"

-

90

53

38

35

44

1

55

16

12

0,43

46

34

337

25

11

7

700

360

260

3950

2540

1960

3160

1820

1380

679

437

-

-

-

-

-

-

-

-

-

44

29

26

1,5

0,5

3/4"

1/2"

90

46

38

35

37

1

55

16

12

0,43

46

34

311

15

10

6

700

360

260

3000

2340

1810

2180

1680

1270

516

402

2730

2290

1960

240

201

172

12

8

6

62

38

32

2,1

-

3/4"

-

90

1

61

20

14

0,47

61

47

41

52

458

36

16

12

880

500

380 centrifugal

4980

3210

2660

3810

2270

1860

857

552

52

40

230V/1/50Hz

-

-

-

-

-

-

-

-

-

64

38

32

2,1

0,6

3/4"

1/2"

90

1

61

20

14

0,47

61

47

41

52

52

40

423

35

16

11

880

500

380

4610

2970

2460

3530

2100

1720

793

511

3570

2810

2480

313

247

218

22

15

12

82

34

30

3,0

-

3/4"

-

90

1

33

14

9

0,71

50

43

39

41

54

38

482

25

12

6

1100

680

460

6000

4050

2800

4200

2770

1900

1032

697

-

-

-

-

-

-

-

-

-

122

H max. speed; M med. speed; L min. speed

Heating mode

2 pipes system configuration

(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C;

ΔT water 10°C

2 pipes system configuration (EUROVENT)

(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode

4 pipes system configuration (with additional heat exchanger) (EUROVENT)

(3)Room air temperature 20°C b.s.; Inlet water temperature 70°C;

ΔT water 10°C

Cooling mode (EUROVENT)

(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C

(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2

(6) Sound pressure level (A-weighted) measured in the room with volume V=100m 3 , reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m

Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

41

35

4,5

-

3/4"

-

90

1

135

33

16

0,80

60

50

44

51

58

38

922

38

19

10

1750

1100

750

11000

7500

5360

8470

5730

4040

1892

1290

-

-

-

-

-

-

-

-

-

8800

6300

1892

1290

922

34

17

9

21747

14729

10531

1908

1292

924

42

21

11

13000

66

124

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

786

38

22

10

1750

1100

750

8800

6220

4570

6770

4670

3370

1514

1070

12500

9300

7050

1097

816

618

29

17

10

41

37

4,5

1,5

3/4"

1/2"

90

1

135

33

16

0,80

60

50

46

51

58

38

Dimensions (mm)

FCLI 32 - 34 - 42 - 44 - 62 - 64

FCLI 32 V2 - 34 V2 - 42 V2 - 44 V2 - 62 V2 - 64 V2

FCLI 32 VL - 34 VL - 42 VL - 44 VL - 62 VL - 64 VL

GLLI 10

GLLI 10N

Mod. FCLI

Weight kg

Mod. FCLI

Weight

Mod. FCLI

Weight kg kg

FCLI 82 - 122 - 124

FCLI 82 V2 - 122 V2 - 124 V2

FCLI 82 VL - 122 VL - 124 VL

32

20,5

32 V2

20,5

32 VL

20

34

21

34 V2

21

34 VL

20,5

42

20,5

42 V2

20,5

42 VL

20

GLLI 10

GLLI 10N

44

21

44 V2

21

44 VL

20,5

62

22

62 V2

21

62 VL

21,5

64

22,5

64 V2

22,5

64 VL

22

GLLI20

GLLI 20N

Mod. FCLI

Weight

Mod. FCLI

Weight kg

82

35

82 V2

35 kg

Mod. FCLI

Weight kg

32 VL

34

All specifications are subject to change without prior notice.

Although every effort has been made to ensure accuracy, Aermec does not assume responsibility or liability for eventual errors or omissions

122

36

122 V2

36

124

36

124 V2

36

122 VL

35

124 VL

35

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italy

Telephone 0442633111 - Telefax 044293577 www.aermec.com

FCLI

67

FCW

Fan coils

Wall-mount installation

Aermec

is participating in the EUROVENT Program: FCH

The related products can be found at the website www.eurovent-certification.com

• VERSIONS WITH INTERNAL 2- OR 3-WAY VALVE

• QUICK AND EASY INSTALLATION

• COMPACT DIMENSIONS

Features

By appropriately combining the options available, it is possible to select the model that satisfies the specific system requirements.

Sale code description:

Code

FCW

Size

21-31-41

Valve

2V (with internal 2-way valve)

3V (with internal 3-way valve)

VL (without valve)

Microprocessor control

(Empty) with control board

N without control board

FCW is a fan coil model for wall-mount installations, whose elegance and reduced dimensions make it aesthetically pleasing; this terminal is thus suitable for applications in residential or light commercial sectors.

The product is configurable and available with or without (2- or 3-way) valve, as well as with or without control board, which ensures c o m p a t i b i l i t y w i t h v a r i o u s s y s t e m requirements.

Fan coils without control board must be necessarily combined with an external control device.

Cream Colour

Display on the front panel

• Three-speed cross flow fan

• Maximum silence

• Aesthetically styled with flat panel

• Air flow louvered fins with horizontal adjustment facility

• Motorised deflector louvers that can be activated by remote control TLW2 and remote panel PFW2 for vertical orientation of the outlet air with 4 fixed positions and continuous oscillation

• Timer for programming switch-off or switchon (TLW2 and PFW2)

Accessories

• Program for operation in automatic, cooling, heating, ventilation and air ionising mode

(TLW2 and PFW2);

• Night time Well-being Program (TLW2)

• Automatic season change (TLW2 and PFW2)

• Automatic re-start after power cut (TLW2 and

PFW2)

• Easy installation and maintenance.

• Air filter with easy extraction and cleaning

• Full compliance with accident-prevention standards.

For models with control board installed

FCW_2V, 3V, VL it is mandatory to select among the user interfaces designed for the

FCW series (TLW2 or PFW2)

For models without control board installed

FCW_2VN, 3VN, VLN a user interface must be mounted outside the fan coil, using either a visible or a recessed wall-mount installation.

To make the selection, please refer to the

"control panels" or "VMF system" sheets, where you will find comprehensive information on this topic.

Remote control TLW2

(mandatory accessory for versions with controller FCW_2V, FCW_3V, FCW_VL):

This accessory is required for operating the fan coil as an alternative to the wired remote control panel PFW2; it is not possible to use two remote control models at the same time.

Infrared remote control with liquid crystal display for controlling all unit functions.

The remote control is delivered separately from the fan coil; with a single remote control it is possible to control more than one fan coil.

The remote control is equipped with a support that allows you to hang it on the wall, from which it can be operated without having to be removed.

Wired control panel PFW2

(mandatory accessory for versions with controller FCW_2V, FCW_3V, FCW_VL):

This accessory is required for operating the fan coil as an alternative to the wired remote control panel TLW2; it is not possible to use two remote control models at the same time.

The PFW2 panel can control only one fan coil.

The panel must be wall-mounted and connected to the fan coil using the 7.5-metre long cable provided.

68

Technical data

Mod.

FCW

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

(1) W

Thermal power (70°C)

Water flow rate

(1)

(1)

(1)

(1)

W

W l/h l/h

Pressure drops

Thermal power (50°C)

Water flow rate

Pressure drops

(1)

(2)

(2)

(2)

(1)

(1)

(1)

(2)

(2)

(2)

(2)

(2)

(2) l/h kPa kPa kPa l/h kPa kPa kPa

W

W

W l/h l/h

COOLING PERFORMANCE

Total cooling capacity

Sensitive cooling capacity

Water flow rate

Water pressure drops

Air flow rate fans

Input power

Maximum input current

Sound power

Sound Pressure

Water content

Coil connections

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(4)

(4)

(4)

(5)

(5)

(5) l/h l/h l/h kPa kPa kPa m

3

/h m 3 /h m

3

/h type n°

W

W

W

(A)

W

W

W

W

W

W dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l

ø Gas (F)

Speed

H

M

L

H

M

L

H

M

L

M

L

L

H

H

M

M

L

L

H

H

M

L

H

M

H

M

L

M

L

L

H

H

M

L

H

M

H

M

L

H

M

L

212V

24

2400

1800

1400

327

249

189

21

13

8

4031

3020

2353

354

265

206

9

14

53

48

42

44.5

39.5

34.0

1

27

24

23

0.13

327

249

189

23

14

9

380

330

270

1900

1450

1100

1550

1200

920

213V

24

2400

1800

1400

327

249

189

21

13

8

4031

3020

2353

354

265

206

9

14

53

48

42

44.5

39.5

34.0

1

27

24

23

0.13

327

249

189

23

14

9

380

330

270

1900

1450

1100

1550

1200

920

21VL

4

2560

2180

1700

353

299

236

8

6

4

4297

3660

2852

377

321

250

9

6

53

48

42

44.5

39.5

34.0

1

27

24

23

0.13

353

299

236

9

7

5

389

340

280

2050

1740

1370

1730

1470

1160

312V

13.4

3000

2600

1940

413

358

267

26

20

12

5035

4363

3256

442

383

286

29.4

22.7

53

48

42

44.5

39.5

34.0

1

27

23

22

0.13

413

358

267

29

22

13

440

390

320

2400

2080

1550

1970

1680

1280

313V

13.4

3000

2600

1940

413

358

267

26

20

12

5035

4363

3256

442

383

286

29.4

22.7

2400

2080

1550

1970

1680

1280

413

358

267

29

22

13

440

390

320 tangential

1

27

23

22

0.13

53

48

42

44.5

39.5

34.0

31VL

8.6

3120

2690

2220

430

370

306

14

10

7

5245

4515

3734

460

396

328

15.9

12.1

53

48

42

44.5

39.5

34.0

1

27

23

22

0.13

430

370

306

15

11

8

446

400

330

2500

2150

1780

2040

1820

1510

412V

21

4750

4310

3750

654

593

516

28

24

18

7972

7234

6294

699

635

552

32

27

54

49

44

45.5

40.5

35.5

1

48

41

31

0.23

654

593

516

32

27

21

540

470

370

3800

3450

3000

2850

2500

2010

413V

21

4750

4310

3750

654

593

516

28

24

18

7972

7234

6294

699

635

552

32

27

54

49

44

45.5

40.5

35.5

1

48

41

31

0.23

654

593

516

32

27

21

540

470

370

3800

3450

3000

2850

2500

2010

41VL

Speeds connected

H

M

L

½” F

V3

V2

V1

½” F

V3

V2

V1

½” F

V3

V2

V1

½” F

V3

V2

V1

½” F

V3

V2

V1

230V/1/50Hz

½” F

V3

V2

V1

½” F

V3

V2

V1

½” F

V3

V2

V1

½” F

V3

V2

V1

Electric power supply

H maximum speed; M medium speed; L minimum speed

Heating

2-pipe system configuration

(1) Ambient air temperature 20°C d.b.; Inlet water temperature 70°C; DT water 10°C

2-pipe system configuration (EUROVENT)

(2) Ambient air temperature 20°C d.b.; Inlet water temperature 50°C; Water flow rate the same as in Cooling mode

Cooling (EUROVENT)

(3) Ambient air temperature 27°C d.b./19°C w.b.; Inlet water temperature 7°C; DT water 5°C

(4) Sound power based on the measurements carried out in accordance with Eurovent 8/2 standard

(5) Sound pressure level (A weighted) measured in environment with volume V=85m3 , reverberation time t=0.5s directivity factor Q=2; distance r=2.5m

Note: The speeds connected can differ from the factory standard configuration, for more information refer to the selection program and to the technical documentation available at www.aermec.com

54

49

44

45.5

40.5

35.5

1

48

41

31

0.23

702

643

528

26

21

15

684

602

476

4080

3740

3070

3470

3100

2590

16

5100

4670

3840

702

643

528

23

19

14

8560

7846

6444

751

688

565

26

22

Dimensional data (mm)

C

FCW

Height

Width

Depth

Weight

A

B

C kg

21

298

880

205

9

31

305

990

210

10

41

360

1172

220

19

B

A

TLW2 accessory

PFW2 accessory

Aermec reserves the right to make all the modifications deemed necessary for improving the product, including technical data.

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italia

Tel. 039 0442633111 - Telefax +39 044293577 www.aermec.com

69

70

FHX

Fan coils

With germicidal lamp

Aermec

participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com

FHX-UVP

FHX-UVPO

FHX-UV

Cabinet RAL 9002 heatboard RAL 7044

• GERMICIDAL LAMP INCORPORATED

• ESSENTIAL IN ENVIRONMENTS THAT REQUIRE THE

HIGHEST LEVELS OF HYGIENE

• 3 ROW COIL

The FHX fan coil is fitted with an exclusive device for air sterilization, making it essential in environments that require the highest levels of hygiene, such as:

• hospitals

• dentists' surgeries

• doctors' and vets' surgeries

• analysis laboratories

• pharmaceutical companies

• waiting rooms

• beauty institutes

• homes

• offices

• public premises

Features

Versions:

FHX-UV: universal free-standing or wall/ceiling mounting.

FHX-UVP: wall-mounted model without cabinet.

FHX-UVPO: wall-mounted model without cabinet, with boosted motor at 6/7 speeds (3 selectable).

• Compatible with VMF System.

• Exclusive air sterilization system with germicidal lamps. Efficiency of 99.999% in the deactivation of all microorganism Gram - and

Gram +

• 3 row coil.

• 3-speed ventilating unit.

• Full compliance with the accident prevention standards.

• Rounded line.

• Quiet operation.

• Low loss of charge in the heat exchange batteries.

• Electric motors with permanently inserted condensers.

• Ease of installation and maintenance.

• Air filter easy to remove and clean.

• Control made by a microprocessor thermostat supplied as an accessory:

- FHX-UVP and UVPO: requires external control panel.

- FHX-UV: The control panel may be fitted on board the unit or externally.

• FHX-UV: Metal protection cabinet with varnishing in anticorrosion polyester, colour

RAL9002.

• FHX-UV: The air delivery and suction louvers are made of plastic material, colour RAL7044

• Adjustable air delivery louver on version UV except models 62 and 82.

Accessories

AMP20: kit for the wall mounting installation

BC: Auxiliary condensate drip tray.

GA: Intake louver with fixed slats.

GAF: Intake louver with fixed slats and filter.

GM: Delivery louver with adjustable slats.

PA: Intake Plenum made of galvanized steel sheet, provided with Intake Connections for

Circular Section Ducts.

PA-F: Intake plenum that allows to have the intake and the delivery on the same side, suitable for all the installations where it is requested to put the appliance outside the airconditioned rooms in order to reduce to the minimum the noise and facilitate the maintenance operations.

PC: Rear cover panel. Conveniently covers exposed rear fancoil sections. The panel is required by current safety standards for units installed away from the room wall.

PM: Delivery plenum in galvanized steel with external insulation, with plastic outlet connections for circular section ducting.

RD: Delivery straight duct connection.

RDA: Intake straight duct connection.

RP: Delivery 90° duct connection.

RPA: Intake 90° duct connection.

SE: Manually operated fresh air intake louver.

SIT 3-5: Thermostat interface cards. They allow to set up a fancoils network (max. 10) commanded by a centralised panel (switch or thermostat).

SIT3: commands the three speeds of the fan and must be installed on each fancoil of the network; it receives the commands from the switch or from the SIT5 card.

SIT5: commands the 3 fan speeds and up to two valves (four-pipe systems); it sends the thermostat commands to the fancoils network.

SW: Probe for the electronic thermostats which permits operation of the unit only with water above 35 °C.

VCF: The SW3 probe must be combined to

this accessory.

Kit complete with copper connections and 3 way valves all or nothing type, to be powered by a 230 V ~ 50Hz, 24 V ~ 50Hz voltage supply.

Attention: The VCF valve and the drip tray

BC4 can be installed at the same time as the fan coil.

VCFD: The SW3 probe must be combined to

this accessory.

Kit complete with copper connections and 2 way valves all or nothing type, to be powered by a 230 V ~ 50Hz, 24 V ~ 50Hz voltage supply.

Attention: The VCFD valve and the drip tray

BC4 can be installed at the same time as the fan coil.

ZX: Feet for built-in installation.

Compulsory accessories to choose from

PXAE: Electronic thermostat simplified controls with only 2 selectors for adjusting temperature and fan speed (3 speeds, manual or automatic control). Continuous or thermostated ventilation. Wall installation.

PXAI: Electronic thermostat simplified controls with only 2 selectors for adjusting temperature and fan speed (3 speeds, manual or automatic control). Water temperature sensor included.

Control panels and VMF System: the characteristics are described on the appropriate card.

AMP 20

4

BC

5

6

8

GA

GAF

62

22

32

9

22

32

42

GM

PA

42

62

22

32

42

62

22

32

PA

42

62

22F

32F

42F

62F

23

PC

PM

33

43

62

22

32

42

62

PXAE

PXAI

Accessories

(1)

(1)

(2)

(2)

Size (FHX)

22 32 42 50 62 82

• • • • •

• •

• •

• • • •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

Versions

UVP-UVPO

UV-UVP-UVPO

UV-UVP-UVPO

UV-UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UV

UV

UV

UV

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UV-UVP-UVPO

UV

Accessories

RD

RDA

RP

RPA

SE

SIT3

SIT5

SW3

VCF

VCFD

ZX

2

3

124

224

324

7

8

41

42

43

4124

4224

4324

1

42

62

22

32

42

62

22

32

62

22

32

22

32

42

42

62

20X

30X

40X

80X

(3)

(3)

(3)

(3)

Size (FHX)

22 32 42 50 62 82

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• •

• • • •

• •

UVP-UVPO

UVP-UVPO

UVP-UVPO

UV-UVP-UVPO

UV-UVP-UVPO

UV-UVP-UVPO

UV-UVP-UVPO

UV-UVP-UVPO

UV-UVP-UVPO

UV-UVP-UVPO

UV-UVP-UVPO

UV-UVP-UVPO

UV-UVP-UVPO

UV-UVP-UVPO

UV-UVP-UVPO

UV-UVP-UVPO

UV-UVP-UVPO

UV-UVP-UVPO

UVP-UVPO

UVP-UVPO

Versions

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

UVP-UVPO

(1)

BC8 and BC9 are not applicable to fan coils with cover cabinets

(2) compulsory accessory

(2)

SE accessories are matched with ZX feet

71

Technical data

Mod.

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

(1) W

Heating capacity (70°C)

(1) W

(1)

(1)

W l/h

Water flow rate

(1)

(1)

(1) l/h l/h kPa

Pressure drop

Heating capacity (50°C)

(1)

(1)

(2)

(2) kPa kPa

W

W

(2)

(2)

W l/h

Water flow rate

Pressure drop

(2)

(2)

(2)

(2) l/h l/h kPa kPa

(2) kPa

COOLING PERFORMANCE

Total cooling capacity

Sensible cooling capacity

Water flow rate

Pressure drop

Air flow rate

Fans

Absorbed power

Absorbed power with germicidal lamp

Total input power (UV/UVP)

Total input power (UVPO)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3)

(3) l/h l/h kPa kPa kPa m 3 /h m

3

/h m 3 /h

W

W

W

W

W

W l/h

W

W

W

A type n°

W

W

W

Sound power level

Sound pressure level

(4)

(4)

(4)

(5)

(5)

A dB(A) dB(A) dB(A) dB(A) dB(A)

(5) dB(A)

Water content

Coil connections l

ø

Vel.

H

M

L

H

M

L

H

M

L

H

M

L

L

H

M

L

H

M

M

L

H

L

H

H

M

M

L

H

M

L

H

M

L

M

L

H

M

L

H

M

L

H

M

L

H

Speed connected

Power supply

H

M

L

FHX22

23

0,79

1/2"

V3

V2

V1

0,37

50

43

31

42

35

1

25

22

19

50

47

44

0,12

210

144

6

5

3

290

220

140

1500

1220

840

1240

1000

670

258

2960

2531

1906

260

222

167

6

4

3

1770

1510

1130

258

210

144

6

5

2

H max. speed; M med. speed; L min. speed

Heating mode

2 pipes system configuration

(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; DT water 10°C

2 pipes system configuration (EUROVENT)

(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode

Cooling mode (EUROVENT)

(3) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C

(4) Sound power level on the basis of measurements made in compliance with Eurovent 8/2

(5) Sound pressure level (A-weighted) measured in the room with volume V=85m

3

, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m

Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

FHX42 FHX50

478

397

15

13

8

9918

5521

4062

581

484

356

15

11

6

3960

3300

2430

585

478

397

14

10

7

600

460

330

3400

2780

2310

2760

2110

1630

585

Centrifugal

29

1,48

3/4"

V3

V2

V1

0,63

51

44

37

43

36

2

57

43

30

82

68

55

0,28

230V/1/50Hz

604

432

19

14

8

720

600

400

4190

3510

2510

3000

2540

1790

721

34

1,48

3/4"

V3

V2

V1

0,48

56

51

42

48

43

2

67

46

34

92

71

59

0,35

604

432

15

11

6

8191

7529

5021

718

660

440

15

13

6

4870

4480

3000

721

FHX32

26

1,11

1/2"

V3

V2

V1

0,57

48

41

34

40

33

2

44

33

25

69

58

50

0,21

316

267

28

17

13

450

350

260

2400

1840

1550

1900

1570

1110

413

5354

4065

3165

470

357

278

20

12

8

3160

2400

2060

413

316

267

16

10

7

FHX62

34

2,52

3/4"

V3

V2

V1

0,92

57

51

42

49

43

3

82

61

40

182

161

140

0,4

752

554

17

14

8

920

720

520

4860

4370

3220

3980

3300

2440

836

12919

10942

8327

1133

960

730

17

12

7

7500

6430

4880

836

752

554

9

7

4

FHX82

43

2,52

3/4"

V3

V2

V1

1,06

61

56

51

53

48

3

106

80

59

206

180

159

0,49

860

738

22

12

9

1140

930

700

6910

5000

4290

5680

3780

2970

1189

15140

13349

10771

1328

1171

945

21

16

11

7960

6860

5200

1189

860

738

21

12

9

72

Dimensions and Weight wall-mounted model with cabinet wall-mounted model without cabinet universal free-standing or wall/ceiling mounting with cabinet

B

C

B

C

universal free-standing or wall/ceiling mounting without cabinet

C

D

B

A

FHX22-32-42-50UV

Mod FHX_UV

Height

Widht

Depth

Weight

A mm

B mm

C mm kg

Mod FHX_UVP/UVPO

Height

Widht

Depth

Weight

A mm

B mm

D (6) mm

C mm kg

(6) Maximum size (including the electrical box)

22

453

522

572

216

16

22

520

750

220

16

A

A

FHX62-82UV

32

453

753

823

216

26

32

520

980

220

26

42

520

1200

220

25

42

453

973

1043

216

25

FHX22-32-42-5062-82UVP/UVPO

50

520

1200

220

25

50

453

973

1043

216

25

62

590

1320

220

35

62

453

1122

1205

216

35

82

590

1320

220

35

82

453

1122

1205

216

35

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italy

Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577 www.aermec.com

73

PMZ

Plenum with motorized dampers for ducted fan coils

MULTIZONE PLENUM TO CONTROL THE AIR FLOW

• TO BE COMBINED WITH FCX_I AND VED_I FAN COILS WITH

INVERTER MOTOR

• PERFECT FOR RESIDENTIAL AND SERVICES SECTORS

APPLICATIONS

• WIRELESS THERMOSTATS

Characteristics

• The plenums with motorized dampers have been designed for residential and service sectors applications. it allows to combine an optimal environmental comfort with an assured energy saving.

More and more in modern systems one needs to have a global climatization through ducted systems. The accessory PMZ, thanks to the

electronic control of dampers, regulates the room comfort, adjusting the air flow to actual needs.

PMZ has been designed to be combined with fan coils with inverter motor.

• The structure is made of galvanized sheet , internally insulated with self-extinguishing material. It is provided with a variable number from 2 to 6 circular attacks, equipped with motorized dampers in two positions

(open/closed) depending on the combined model.

The damper motor is controlled directly from the wireless room thermostat. With the plenum it is provided a room thermostat for each motorized damper.

Regulation: the regulation system adjusts the

air flow provided by the fan coil according to the number of open dampers.

The state of the damper (open/closed) is regulated by reaching the temperature set in each room.

The control system is also able to control the valves of on / off type, two or three-way valves for two or four pipe configuration.

30°C room air temperature set 25°C damper n°1 open

30°C room air temperature set 25°C damper n°3 open

25°C room air temperature set 25°C damper n°2 closed

74

(1) Alle condizioni di portate aria e acqua nominali

Compatibility Plenum with fancoils

FANCOIL

FCXI20/24P

FCXI30/34P

FCXI40/44P

FCXI50/54P

FCXI80/84P

VED030/040I

VED130/140I

VED230/240I

VED330/340I

VED530/540I

VED730/740I

PLENUM

2 DELIVERIES

PMZ22

PMZ32

PMZ42

-

-

PMZ22

PMZ32

PMZ42

-

-

-

PLENUM

3 DELIVERIES

-

PMZ33

PMZ43

PMZ43

PMZ83

-

PMZ33

PMZ43

PMZ83

-

-

Technical data

Mod. FCXI_P Vel.

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

Heating capacity (50°C)

Water flow rate

(1)

(1)

W l/h

H

H

20

2100

258

24

2320

298

30

3160

380

HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)

Heating capacity (70°C) (2) W H 1751 2826

Water flow rate (2) l/h H 154 248

COOLING PERFORMANCE

Total cooling capacity

Water flow rate

Air flow rate

Fans

Max. high static pressure

Absorbed power

Absorbed power (plenum)

(3)

(3)

W l/h m 3 /h type n°

Pa

W

W

H

H

H

H

1500

258

290

1

50

12

1730

298

290

1

50

12

2210

380

450

2

56

13

PLENUM

4 DELIVERIES

-

-

PMZ44

PMZ44

PMZ84

-

-

PMZ44

PMZ84

PMZ504

-

34

3550

482

-

-

40

4240

585

3460

303

44

5250

765

-

-

PLENUM

5 DELIVERIES

-

-

-

-

-

-

-

-

-

PMZ505

PMZ705

50

4900

721

4223

370

54

6100

855

-

-

PLENUM

6 DELIVERIES

-

-

-

-

-

-

-

-

-

-

PMZ706

80

7990

1276

6410

562

84

10207

1479

-

-

2800

482

450

2

56

13

3400

585

4450

765

600 centrifugal

600

2 2

53

17

53

17

5

4190

721

720

2

46

37

4970

855

720

2

46

37

7420

1276

1140

3

30

80

8600

1479

1140

3

30

80

Mod. VED_I Vel.

030 040 130 140 230 240 330 340 530 532 540 541 730 732 740 741

HEATING PERFORMANCE (2 PIPE CONFIGURATION)

Heating capacity (50°C)

Water flow rate

HEATING PERFORMANCE

(4 PIPE CONFIGURATION)

Heating capacity (70°C)

(1)

(1)

(2)

W l/h

W

H 2180 2340 3750 3940 4320 4750 6270 6550 10420

H 279 327 516 566 588 691 860 922 1335

with

BV030

H 2220 -

with

BV130

3780 -

with

BV230

4493 -

with

BV330

5888 -

-

-

13540

11820

1543

-

-

-

8850

17280

2382

-

-

-

22174

19150

2766

-

-

-

14500

Water flow rate

COOLING PERFORMANCE

Total cooling capacity

Water flow rate

Air flow rate

Fans

Max. high static pressure

Absorbed power

Absorbed power (plenum)

(2)

(3)

(3) l/h

W l/h m 3 /h type n°

Pa

W

W

H 196 331 394 515 1188 776 1945 1272

H 1624 1900 2997 3290 3420 4020 5000 5360 7760 7760 8970 8970 13850 13850 16080 16080

H 279 327 516 566 588 691 860 922 1335 1335 1543 1543 2382 2382 2766 2766

H 285 277 433 420 590 570 805

H

1

61

36

1

61

36

2

60

45

2

60

45

2

64

53

2

63

53

3

66

86

775 1520 1520 1500 1500 2410 2410 2350 2350 centrifugal

3 2

64

86

58

205

2

56

185

2

56

205

2

56

185

3

69

370

3

69

363

3

69

370

3

69

363

5

H max. speed;

2 pipes system configuration (EUROVENT)

(1) Room air temperature 20°C b.s.; Inlet water temperare 50°C; Water flow rate as in cooling mode

4 pipes system configuration (with additional heat exchanger) (EUROVENT)

(2) Room air temperature 20°C b.s.; Inlet water temperare 70°C; ΔT water 10°C

Cooling performance (EUROVENT)

(3) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperare 7°C; DT water 5°C

Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com

Dimensions (mm)

A

C

D

Acessories Plenum

Height

Width

Depth

Delivery

Weight

200

200

A

B

C

D n°

Ø kg

B

200

644

380

180

2

200

9

875

380

180

2

200

9

875

380

180

3

200

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

11

1095

380

180

2

200

10

WARNING

The brackets supplied as standard are higly recommended to install fan coils – from 20 to 54 size – with their plenums

PMZ22 PMZ32 PMZ33 PMZ42 PMZ43 PMZ44 PMZ83 PMZ84 PMZ504 PMZ505 PMZ705 PMZ706

216 216 216 216 216 216 216 216 300 300 351 351

1095

380

180

3

200

13

1095

380

180

4

200

14

1224

380

180

3

200

13

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italia

Tel. 0442633111 - Telefax 044293577 www.aermec.com

1224

380

180

4

200

14

1231

380

180

4

200

22

1231

380

180

5

200

24

1631

380

180

5

200

32

1631

380

180

6

200

35

75

Ventilcassaforma

Template for recessed installation of fancoils in the wall

CHF

CHU L

Ventilcassaforma has been designed to respond to the needs to rationalise spaces to suit modern interior architecture.

Ventilcassaforma is a galvanised template that makes it possible to make a space to house fan coils in the wall. The template will make masonry work easier during the construction of a niche where the fan coil will be installed. When the work is finished, the fan coil will be completely hidden from view.

Ventilcassaforma is available in two versions with the same characteristics but designed to house fan coils from two different series:

- CHU-L for fan coils in the Omnia UL-P series

- CHF for fan coils in the FCX-P , FCX-PV and FCXI-P series in 2 pipe systems, 2 pipe systems with resistance and with

4 pipe systems

Features

• Available in two versions for combined fan coils:

CHU-L: Ventilcassaforma for the

OMNIA UL-P series. Available in four sizes

CHF: Ventilcassaforma for FCX-P , FCX-PV and FCXI-P fan coils. Available in 5 sizes

Compatible with VMF System

Ventilcassaforma is made up of the following parts to be assembled:

- Recess box;

- Closure panel;

- Outer frame with deflector;

- Cover bases, cross-members, covers.

All parts are made of galvanised steel and treated with epoxy-polyester resinbased thermo-hardening base paint in grey with rough glazed finish in order to hold the paint. The final colour can be chosen by the client.

Closure Panel: Made of galvanised steel, this is the box housing the fan coil. The box is recessed in the wall during building work making the construction of a niche where the fan coils will be installed much easier. Holes for fitting the fan coil and preparing an electric plant with a socket and GEWISS fuse holder are already present on the back panel. The box can accommodate the hydraulic system pipes and condensation drain pipes thanks to the presence of several easily-removable elements on the sides and base.

Closure Panel: made of steel pre-treated with base paint and no slots present.

Easily removable for servicing and cleaning the air filter.

Outer Frame: the perimeter of the box has an outer frame made of pre-treated steel making it possible to cover the perimeter part of the wall and hide any imperfections that overtime show possible crumbling on the edge of the plaster work.

Deflector: manual, with which the flow of air can be directed into the room. The deflector is incorporated in the frame.

76

Ventilcassaforma - Omnia UL combination

Ventilcassaforma

Fan coil

Ventilcassaforma CHU L + Omnia UL combination

CHU 12 L CHU 17 L

Omnia UL 11 P Omnia UL 16 P

CHU 27 L

Omnia UL 26 P

CHU 37 L

Omnia UL 36 P

Ventilcassaforma

Fan coil

CHF 17

FCX 17 P

FCX 17 PV

Ventilcassaforma CHF + FCX P - FCX PV - FCXI P combination

CHF 22

FCX 22 P

FCX 22 PV

CHF 32

FCX 32 P - 36 P

FCX 32 PV - 36 PV

CHF 42

FCX 42 P - 50 P - 56 P

FCX 42 PV - 50 PV - 56 PV

FCX 24 P

FCX 24 PV

FCXI 20/24 P

FCX 34 P

FCX 34 PV

FCXI 30/34/36 P

FCX 44 P - 54 P

FCX 44 PV - 54 PV

FCXI 40/44 P - 50/54/56 P

CHF 62

FCX 62 P - 82 P - 102 P

FCX 62 PV - 82 PV - 102 PV

FCX 64 P - 84 P

FCX 64 PV - 84 PV

FCXI 80/84 P

The fan coils FCX-P , FCX-PV and FCXI-P can be inserted into 2 pipe systems, 2 pipe systems with resistance and 4 pipe systems

Dimensions (mm)

CHU

Height

Width

Depth

A

A1

B

B1

C

12 L

691

648

692

644

186

17 L

691

648

802

754

186

27 L

691

648

1032

984

186

37 L

691

648

1252

1204

186

CHF

Height

Width

Depth

A

A1

B

B1

C

17

728

684

732

684

240

22

728

684

842

794

240

32

728

684

1073

1025

240

42

728

684

1293

1245

240

62

833

789

1414

1366

240

Outer frame and closure panel

CHU

Height

Width

A

A1

A2

A3

B

B1

12 L

724

634

70

494

713

633

17 L

724

634

70

494

823

743

27 L

724

634

70

494

1053

973

37 L

724

634

70

494

1273

1193

CHF

Height

Width

A3

A4

B

B1

A

A1

A2

17

760

680

93

493

94

753

673

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

22

760

680

93

493

94

863

783

32

760

680

93

493

94

1094

1014

42

760

680

93

493

94

1314

1234

62

865

785

93

598

94

1435

1355

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italy

Tel. 0442633111 - Telefax 044293577 www.aermec.com

A4

77

Control panels

Range of control panels for fan coils

• WIDE RANGE OF CONTROL PANELS FOR AN EASY AND

COMPLETE CONTROL OF ALL FUNCTIONS OF THE FAN COIL

WMT21: Electronic thermostat for inverter fan coils installed in:

1.

2.

2-pipe systems

4-pipe systems

Overall dimensions (mm):

H=87 - W=132 - D=31

Features and standard equipment

Wall-mount installation

• Automatic / manual season change

• Thermostated control of up to 2 On/Off valves

• Temperature and ventilation (3 speeds) control or continuous adjustment

• Internal air probe

Accessories manageable (1) by type of system

Hot water valve

Cold water valve

Air probe (SWAI)

Water probe (SWAI)

2 pipes

2 pipes with resistance

-

-

-

-

4 pipes

FMT21 : Electronic thermostat for fan coils installed in:

1. 2-pipe systems

2. 2-pipe systems with resistance

3. 4-pipe systems

Overall dimensions (mm):

H=80 - W=113 - D=50

Features and standard equipment

• Recessed installation (module 503 box)

• Automatic / manual season change

• Control of up to 2 On/Off valves, or 1 valve and 1 resistance

• Temperature and ventilation (3 speeds) control

• Internal air probe

Accessories manageable (1) by type of system

Hot water valve

Cold water valve

Air probe (SWA)

Water probe (SWA)

SIT3

SIT5

Electric resistance

2 pipes

-

-

-

2 pipes with resistance

-

-

-

-

-

4 pipes

TPF: Electronic thermostat with thermostated or continuous ventilation for fan coils in:

1.

2.

2-pipe systems

4-pipe systems

Overall dimensions (mm):

H=45 - W=75 - D=46

Features and standard equipment

• Recessed installation (module 503 box)

• Automatic / manual season change

• Control of up to 2 On/Off valves,

• Temperature and ventilation control

• Internal air probe

• Water probe (supplied)

Accessories manageable (1) by type of system

Hot water valve

Cold water valve

Air probe

Electric resistance

2 pipes

-

-

2 pipes with resistance

-

-

4 pipes

-

-

Features and standard equipment

• Wall-mount installation

• Automatic / manual season change

• Control of up to 2 On/Off valves

• Temperature and ventilation (3 speeds) control

• Internal air probe

• Louvre and external contact management

PXAE: Electronic thermostat with thermostated or continuous ventilation for fan coils in:

1.

2.

2-pipe systems

4-pipe systems

Overall dimensions (mm):

H=148 - W=70 - D=27.5

Accessories manageable (1) by type of system

Hot water valve

Cold water valve

Water probe (SW3)

SIT3 e SIT5

2 pipes

-

2 pipes with resistance

-

4 pipes

PXAR: Electronic thermostat with thermostated or continuous ventilation for fan coils in:

1. 2-pipe systems with resistance

Overall dimensions (mm):

H=148 - W=70 - D=27.5

78

Features and standard equipment

• Wall-mount or fan coil installation

• Automatic / manual season change

• Control of up to 1 On/Off valve and 1 resistance

• Temperature and ventilation (3 speeds) control

• Internal air probe

• Louvre and external contact management

Accessories manageable (1) by type of system

Cold water valve

SIT3 e SIT5

Water probe (SW3)

Electric resistance

2 pipes

-

-

-

-

2 pipes with resistance

4 pipes

-

-

-

-

PXBI: Control panel for fan coils in:

1. 2-pipe systems with or without valve

Features and standard equipment

• Fan coil installation

• Manual season change

• Control of up to 1 On/Off valve,

• Temperature and ventilation (3 speeds) control

• Internal air probe

Overall dimensions (mm):

H=145 - W=70 - D=29

Accessories manageable (1) by type of system

Hot water valve

Cold water valve

SIT3 e SIT5

2 pipes

2 pipes with resistance

-

-

-

4 pipes

-

-

-

PXAI: Electronic thermostat with thermostated or continuous ventilation for fan coils in:

1.

2.

2-pipe systems

4-pipe systems

Overall dimensions (mm):

H=148 - W=70 - D=27.5

Features and standard equipment

• Fan coil installation

• Automatic / manual season change

• Control of up to 2 On/Off valves

• Temperature and ventilation (3 speeds) control

• Internal water (2.5m) and air (2.3m) probes

• Louvre and external contact management

Accessories manageable (1) by type of system

Hot water valve

Cold water valve

SIT3 e SIT5

2 pipes

2 pipes with resistance

-

4 pipes

Features and standard equipment

• Even wall-mount installation with the fixing brackets

• Automatic / manual season change

• Control of up to 2 On/Off valves,

• Temperature and ventilation (3 speeds) control

• Air probe inside the function remote control (IFEEL)

• Air probe supplied for installation in fan coil intake

KTLM: Control thermostat kit

(remote control and receiver) for fan coils with casing in:

1.

2.

2-pipe systems with or without valve

4-pipe systems with valve

Accessories manageable (1) by type of system

Hot water valve

Cold water valve

Electric resistance

2 pipes

-

-

2 pipes with resistance

-

4 pipes

-

PTI: Control panel for fan coils in:

1. 2-pipe systems with or without valve

Features and standard equipment

• Fan coil installation

• Automatic / manual season change

• Temperature and ventilation (3 speeds) control

• Internal water (2.5m) and air (2.3m) probes

NEW

PTI2: Control panel for fan coils INVERTER with case:

1. 2-pipe systems with or without valve

2. 4-pipe systems with valve

Features and standard equipment

• Fan coil installation

• Automatic / manual season change

• Control of up to 2 On/Off valves

• Temperature and ventilation (3 speeds) control

• Air probe inside the remote control

• Internal water probe for the control of the minimum or maximum, depending on the plant

Accessories manageable (1) by type of system

Hot water valve

Cold water valve

Electric resistance

2 pipes

-

-

2 pipes with resistance*

-

* is possible too handling the Plasmacluster filter, or germicidal lamp, contact us

4 pipes

-

Accessories manageable (1) by type of system

Hot water valve

Cold water valve

SIT3 e SIT5

2 pipes

2 pipes with resistance

-

-

-

4 pipes

-

-

-

Features and standard equipment

• Even wall-mount installation with the fixing brackets

• Automatic / manual season change

• Control of up to 2 On/Off valves

• Air probe inside the remote control

• Air probe provided for possible fan coil installation

KTLP: Control thermostat kit

(remote control and receiver) for ducted fan coils in:

1.

2.

2-pipe systems with or without valve

4-pipe systems with valve

Accessories manageable (1) by type of system

Hot water valve

Cold water valve

Electric resistance

2 pipes

-

-

2 pipes with resistance

-

4 pipes

-

Features and standard equipment

• Wall-mount installation

• Ventilation control (3 speeds)

Features and standard equipment

• Wall-mount or fan coil installation

• Ventilation control (3 speeds)

PX2: Commutator switch for fan coils in:

1. 2-pipe systems without valve

PX2C6 : Pack of 6 pcs.

Overall dimensions (mm):

H=145 - W=70 - D=29

Accessories manageable (1) by type of system

Hot water valve

Cold water valve

SIT3

2 pipes

-

-

2 pipes with resistance

-

-

-

4 pipes

-

-

-

PX: Commutator switch for fan coils in:

1. 2-pipe systems

Features and standard equipment

• Wall-mount installation

• Manual season change

• Thermostated control of up to 2 On/Off valves

• Temperature and ventilation (3 speeds) control

• Internal air probe

Accessories manageable (1) by type of system

Hot water valve

Cold water valve

SIT3

2 pipes

2 pipes with resistance

-

-

-

4 pipes

-

-

-

WMT06: Electromechanical thermostat with continuous ventilation for fan coils in:

1.

2.

2-pipe systems

4-pipe systems

Accessories manageable (1) by type of system

Hot water valve

Cold water valve

SIT3

Resistance

2 pipes

-

2 pipes with resistance

-

-

-

4 pipes

-

-

Overall dimensions (mm):

H=75 - W=127 - D=25

Features and standard equipment

• Wall-mount installation

• Manual season change

• Temperature and ventilation (3 speeds) control

• Internal air probe

WMT05: Electromechanical thermostat with thermostated ventilation for fan coils in:

1. 2-pipe systems without valve

Overall dimensions (mm):

H=75 - W=127 - D=25

Accessories manageable (1) by type of system

SIT3

2 pipes

2 pipes with resistance

-

4 pipes

-

Features and standard equipment

• Wall-mount installation

• Automatic / manual season change

• Control of up to 2 On/Off valves, or 1 valve and 1 resistance

• Temperature and ventilation (3 speeds) control

• Air probe (supplied) to be installed on the fan coil intake

FMT10: Electronic thermostat for fan coils in:

1.

2.

3.

2-pipe systems

2-pipe systems with resistance

4-pipe systems

Overall dimensions (mm):

H=80 - W=118 - D=40

Accessories manageable (1) by type of system

Hot water valve

Cold water valve

Resistance

2 pipes

-

2 pipes with resistance

-

4 pipes

-

WMT10: Electronic thermostat with thermostated or continuous ventilation for fan coils in:

1.

2.

3.

2-pipe systems

2-pipe systems with resistance

4-pipe systems

Overall dimensions (mm):

H=75 - W=127 - D=25

Features and standard equipment

• Wall-mount installation

• Manual season change

• Control of up to 2 On/Off valves,

• Temperature and ventilation (3 speeds) control

• Internal air probe

Accessories manageable (1) by type of system

Hot water valve

Cold water valve

Resistance

2 pipes

-

2 pipes with resistance

-

Aermec reserves the right to make all the modifications deemed necessary for improving the product, including technical data.

4 pipes

-

(1) for the names of the accessories refer to the fan coil technical sheets.

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italia

Tel. 039 0442633111 - Telefax +39 044293577 www.aermec.com

79

VMF

Variable Multi Flow system

Range of components for the management of air conditioning, heating and domestic hot water systems

Accessory module

Zone interface VMF systems central interface

NEW

VMF-E4D

VMF-E4

*As awared by Chicago Athenaeum:

Museum of the Architecture and Design

Zone interface

VMF-E5N / VMF-E5B

Thermostat with serial communication

VMF-VOC

VMF-CRP

Domestic water panel

VMF-E0

VMF-E1 / VMF-E18

VMF-E2

VMF-E2H

VMF-SW / VMF-SW1

VMF-ACS

* Winner for the International design Award "Good Design 2010" for the "Electronics"

Features

• VMF: Variable Multi Flow system.

Management and control system of hydronic systems for the conditioning, heating and production of domestic hot water.

The VMF system allows complete control of every component of a hydronic system both locally and centrally and, communicating between the various components of the system, manages the performance without ever neglecting the end user's request of comfort, but reaching it as efficiently as possible with energy saving.

If you add the advantages deriving from such an innovative control to the flexibility of a hidronic system, you get a more efficient and effective alternative to the variable refrigerant flow systems (VRF).

The VMF system is extremely flexible, enough to allow various control and manage steps, expandable at different moments:

1) Control of a single fancoil.

2) Control of a microzone (one MASTER fancoil and a maximum of 5 SLAVE fancoils).

3) Control of multi independent zones system

(one MASTER fancoil and a maximum of 5

SLAVE fancoils for each zone).

4) Control of a fancoil system, plus management of the heat pump (if compatible with the VMF system).

5) Control of a fancoil system, heat pump and management of the domestic hot water system (VMF-ACS).

6) Control of a fancoil system, heat pump, domestic hot water production and additional circulators (up to a maximum of 12 using three additional VMF-CRP modules).

7) Control of a fancoil system, heat pump, domestic hot water production, additional circulators and management of heat recovery units, maximum 3, (with the ability to handle up to 3 VMF-VOC sensors) or a boiler.

• The VMF system can operate and manage, through a VMF-E5N / VMF-E5B panel, a maximum of 64 zones consisting of a

MASTER fancoil and a maximum of 5 SLAVE fancoils connected to each MASTER, for a total of 384 fancoils.

• Besides the central control supplied by theVMF-E5N / VMF-E5B panel, the MASTER fancoils must be provided with a local control interface; this interface can be mounted on the fancoil (VMF-E2 / VMF-E2H) or be mounted into a wall panel (VMF-E4).

• Different functions can be controlled through the VMF-E5N / VMF-E5B panel, including:

- Identify the different zones setting a name for each one.

- Check and set the ON-OFF function and the set temperature of each zone.

- Set and manage the set temperature of the heat pump.

- Scheduling time slots.

• Simple installation of the fancoil system through the SELF-MONITORING function of the MASTER fancoils.

80

System components

VMF-E0: thermostat accessory to fix on the side of the fancoil, equipped with air and water sensors as standard, controls 2 pipes, 4 pipes,

2 pipes + Plasmacluster, 2 pipes + UV lamps,

2 pipes + Electric heater systems. Equipped with external contact to be used as low voltage remote ON-OFF. This thermostat can create a single fancoil zone through 2-wire serial communication (1 master + 5 slaves maximum). The thermostat is fuse protected.

VMF-E1: like VMF-E0 with extra:

- Economy contact/presence sensor.

- Auxiliary water sensor for general control in

4-tube systems (with VMF-SW1 accessory).

- Serial RS485, protocol ModBus RTU, for centralised control.

- Possibility to insert expansion cards for future development. The VMF-E1 accessory must therefore be used in the Masters in the presence of multiple zones, or for communication with the chiller/heat pump.

• VMF-E18: the same as the VMF-E1, but for fancoils with inverter motors.

• VMF-E2: this is the user interface on the machine to match to the VMF-E0, VMF-E1 and E18 accessories for the series UL-S-FCX-

AS, FCX-U (sizes 62-64-82-84-102) FCX180U

FHX-U (sizes 62-82). Equipped with 2 selector switches, one for temperature and one for speed control.

VMF-E2D: is the user interface (as above) on the machine, to combine with accessories

VMF and VMF-E0-E1, dedicated to the series

DUALJET.

• VMF-E2H: this is the User Interface (as above) on the machine, to match to the VMF-E0, E1, accessories dedicated to the HL series

• VMF-E4: this is the wall mounted user interface, to match to the VMF-E0, VMF-E1 and

VMF-E18 accessories for the UL, HL, and

FCX series without on-board control.

Innovative design, extremely slim and inexpensive, allows control of functions via a capacitive touch keypad with LCD display.

The environment can be adjusted with the sensor on the panel (standard), or the sensor of the fancoil which it is connected to, or by their arithmetic mean. It also allows the activation of the air purifier accessory

(Plasmacluster / UV Lamp) and the electrical heating element.

• VMF-E4D:is the variant of the previous code, but with frontal gray Pantone 425C (METAL)

• VMF-E5B: white recessed panel, with backlit graphic LCD and capacitive keyboard allows the centralised command/control of a complete hydronic system consisting of Fancoils: up to 64 fancoil zones consisting of a master

+ 5 slaves. Chiller/heat pump equipped with

Modu_Control, GR3 and pCO2/PCO³ controls (accessory required for RS 485 interface with MODU-485A, AER485, AER485P2 /

AER485P1); circulators: up to 12 configurable zone circulators; boiler: boiler consensus management for hot water production; heat recovery units: consents up to 3 per programmable recovery units based on the timing and/or by measuring the air quality obtained with the VMF-VOC accessory; domestic water module: complete management of the domestic hot water production through the control of: diverting/circulator valve, integrated resistor, accumulation temperature sensor, antilegionella circuit.

• VMF-E5N: this is the variant of the previous code, but with black plastic.

• VMF-VOC : accessories for measuring air quality (see related point in the description of the VMF-E5B).

• VMF-CRP: accessory module for the control of the boilers, pumps and heat recovery units.

VMF-SIT3: Interface cards that allow you to connect the thermostats VMF and VMF-E0-E1 to a fan motor with high power (for selection see all the documentation of the thermostat and the fan coil).

• VMF-SW: water sensor may be used in place of the standard supplied with VMF-E0, VMF-

E1 and VMF-E18 thermostats for the installation upstream of the valve.

• VMF-SW1: additional water sensor may be used for 4-pipe systems with VMF-E1 and E18 thermostats for the maximum control in the cold range.

• VMF-ACS3KM: electrical panel for the complete command/control for hot water storage

(3-way control valve, integrated single phase

3kW resistor command, Anti-legionella and temperature sensor).

• VMF-ACS3KTN: electrical panel for the complete command/control for hot water storage

(3-way control valve, integrated three-phase

3kW resistor command, Anti-legionella and temperature sensor).

• VMF-ACS6KTN: electrical panel for the complete command/control for hot water storage

(3-way control valve, integrated three phase

6kW resistor command, Anti-legionella and temperature sensor).

• VMF-ACS8KTN: electrical panel for the complete command/control for hot water storage

(3-way control valve, integrated three phase

8kW resistor command, Anti-legionella and temperature sensor).

• GLL_N: FCL_N grid units, equipped with thermostat card for serial communication with the accessory functions equivalent and VMF-

E1 (this grid is a mandatory accessory for the units FCL N);

• GLLI_N: FCLI_N grid units, equipped with thermostat card for serial communication with the accessory functions equivalent and

VMF-E18, (this grid is a mandatory accessory for the units FCLI N);

Dimensions (mm)

A B C

[mm] [mm] [mm]

VMF-E5B / VMF-E5N 138

VMF-E4 / VMF-E4D 125

110

80

45

11

VMF-ACS 354 544 135

VMF-VOC 79 81 26

VMF-E5B / VMF-E5N

VMF-E4 / VMF-E4D VMF-ACS VMF-VOC

81

Selection 1 • Compatibility of thermostats for serial communication and control interface for MASTER units mod.

FCX

FCXI

HL

UL

FHX

VEC

FCL

FCLI

VED

FCW

DUALJET

Versions

AS - UA - B

U

P - PPC - PO - PV

AS

U

P

S - SM

N

S

P

R

UV

UVP - UVPO

(1)

(7)

N

Note

(8)

(8)

VMF-E0 VMF-E1 VMF-E18 VMF-E2 VMF-E2D VMF-E2H

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

(7)

-

(7)

-

-

-

-

-

-

-

-

-

-

-

-

-

(7)

-

-

-

(7)

-

-

-

(7)

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

VMF-E4 /

VMF-E4D

-

GLL N

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Selection 2 • Compatibility of VMF-E5 7 VMF-E5B centralised control mod.

FCX

FCXI

HL

Versions

AS - U - UA - B

P - PPC - PO - PV

AS - U - P

S

P

S - SM

N

(2)

(1)

(2)

(2)

Note

(2)

(2)

(2)

VMF-E5N / VMF-E5B

-

UL

FHX

VEC

FCL

FCLI

VED

FCW

DUALJET

RI

UV - UVP - UVPO

(2)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

N

Selection 3 • Compatibility of heat pumps with electrical panel for domestic hot water management

*

GLLI N

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

mod.

ANL

ANLI

ANK

SRA

SRP-V1

NRL

NRC

WSH

Versions

H

Tutte

Tutte

Tutte

Tutte

H

H

Tutte

Note

(3) (4)

(4)

(4)

(4)

(4)

(3) (4)

(3) (4)

(4)

Selection 4 • Compatibility of modules and additional sensors

VMF-ACS3KM

mod.

VMF-E5N/ E5D

VED

RePuro

HRS

Versions

Tutte

Tutte

Note

(5) (6)

(9)

(5) (6)

(5) (6)

VMF-CRP

VMF-ACS3KT

VMF-VOC

(6)

(6)

(6)

VMF-ACS6KT

VMF-ACS8KT

VMF-SIT3

Notes:

The versions with the accessories hanging MA or MP, can be treated equally to their respective versions FCX AS U FCX, FCX AU;

(1) This version includes the thermostat E0-VMF and VMF-E2H command interface already installed, these features make these models suitable for operation as a single unit or function of the MASTER microzone plants (plants consist of a single zone, without centralized contol VMF-E5N / VMF-E5B);

(2) To be compatible with the centralized control of VMF-E5N / VMF-E5B, a fan must be set as MASTER of the area, therefore this must be equipped with the thermostat for serial communications, or VMF VMF-E1-E18 and combined with a user interface ( VMF-E2, or VMF VMF-E2H-E4), or units FCL / FCLI equipped with a thermostat on the grid GLL_N / GLLI_N, combined with a command interface VMF-E4 / VMF-E4D ;

(3) The heat pumps with integrated storage are not suitable for production of hot water;

(4) To know the maximum temperature of hot water production (plant and / or health) refer to the limits on the operating unit technical manual;

(5) All types of systems that provide centralized control of VMF-E5N / VMF-E5B, are compatible with the accessory modules (maximum 4) VMF-CRP, and each module can function as a pump controller (4 for each accessory module) or boiler control and recovery (with ON / OFF control and management of 3 recovery boiler in addition to

3 accessories VMF-VOC);

(6) The compatibility of the probe VMF-VOC is only related to the presence of the accessory module in the system with VMF-CRP control function recovery;

(7) VMF-E2: Only for size FCX62U-64U-82U -84U-102U, FCXI80U, FHX62UV-82UV, for other sizes install VMF-E2D, side connections

(8) units must be included in boxes FCLI GLLI_N mandatory accessory grid, this grid is equipped with a card thermostat same rights as VMF-E18 models.

FCL cassette units must provide the mandatory accessory GLL_N grid, this grid is equipped with a card equivalent and thermostat models VMF-E1. To use one of these drives as MASTER is necessary to provide the command interface VMF-E4;

(9) Accessory units required for the combination of VED with thermostats or VMF VMF-E0-E1. Using a VMF-SIT3 for each unit;

(*) Contact us

82

VMF-E5

MODbus RS485

(MAX 1000m)

Chiller

Example of system components

VMF-CRP

n°1 n°2

• A maximum number of 4 VMF-CRP modules

VOC

- Control 4 pumps

VOC n°4 n°3 n°4

VOC accessories must be purchased)

- Control a boiler

VOC

• The only requirement to install VMF-CRP modules is the presence of a VMF-E5 centralised control

VMF-CRP

n°1

VMF-CRP

n°2 n°2 n°3 n°4 n°3

VMF-ACS

VMF-ACS

n°4

VMF-ACS

• The VMF-ACS accessory allows to control the different components needed to produce domestic hot water; for detailed information on the types of systems manageable by VMF-ACS, refer to technical documentation of the accessory

WARNING: in the case where the plant is provided with accessory Multicontrol it will not be possible to use the accessory VMF-ACS, since the production of

VMF-E5 the accessory Multicontrol.

Chiller

Multicontrol

n°1 n°2 n°3 n°4 n°1 n°2 n°3 n°4

VMF-CRP (Multicontrol)

n°1 n°2 n°3

VOC

VOC

VOC

VOC

VOC

VOC x3

Selection 4:

x3

Selection 3:

VMF-E4

B

VMF-E5

Selection 2:

WARNING:: Each chiller must be provided with the appropriate communications accessory Modu-485A

Chiller 1 (Multicontrol) Chiller 4 (Multicontrol)

MODbus RS485

(MAX 1000m)

Chiller

VMF-E4

A

Fancoil 1

(MASTER)

A

A

A

A

A

B

MODbus RS485

(MAX 1000m)

VMF-E4

Fancoil 1 (Slave)

Fancoil 2 (Slave)

Fancoil 3 (Slave)

Fancoil 4 (Slave)

Fancoil 5 (max) (Slave)

B

B

A

VMF-E4

Fancoil 64 (max)

(MASTER)

A

A

Fancoil 1 (Slave)

A

A

B

A

A

Fancoil 1

MODbus RS485 Multicontrol

B

Fancoil 1 (Slave)

VMF-E4

Fancoil 2 (Slave)

Fancoil 3 (Slave)

B

A

A

A

Fancoil 4 (Slave)

A

Fancoil 4 (Slave)

A

Fancoil 5 (max) (Slave)

Fancoil 3 (Slave)

Fancoil 5 (max) (Slave)

A

Fancoil 4 (Slave)

A

Fancoil 5 (max) (Slave)

A

A

A

A

Fancoil 64 (max)

(MASTER)

Fancoil 2 (Slave)

A

A

A

A

A

(MASTER)

Fancoil 3 (Slave)

A

A

A

Fancoil 3 (Slave)

Fancoil 4 (Slave)

Fancoil 5 (max) (Slave)

A

Thermostat for serial connection VMF-E0 / VMF-E1 / VMF-E18

A

B

Commands interface for MASTER unit VMF-E2 / VMF-E2H / VMF-E4

Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.

B

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italy

Tel. 0442633111 - Telefax 044293730 www.aermec.com

83

Climafon

Thermoconvectors

Vertical installation residential use

Flat grid, fixed

with aluminum fins

Aermec presents the brand new natural convection heating system in the CLIMAFON system.

CLIMAFON is born from long experience in the heat exchange field gained within the Giordano Riello International Group, a group in which

Aermec is the leading company.

CLIMAFON is a system terminal that works on the basis of natural convection: the air is heated through an exclusive finned exchange and is sent into the room through a flue effect.

Features

• Enhanced Comfort: CLIMAFON heats rooms quickly and naturally because it basis its operation on air moved by simple convection. The use of CLIMAFON with low temperature heating systems (heat pump, condensation boiler, geothermal and solar...) ensures that the rooms are heated without drying the air. It causes a pleasant sensation of wellbeing that helps to survive even the longest and harshest winters in total relaxation.

Operation at full capacity achieved more

quickly: CLIMAFON has much smaller water content. This enables it to be very fast in heating times and permits it to be used only where it is useful. The speed it takes

CLIMAFON to reach full capacity operation has been checked by TÜV (world leader in product assessment and verification).

Best quality of the air we breath: the air temperature of the air leaving CLIMAFON is such as not to allow the toasting of the powder in the environment. The result is healthy, clean air. In addition to our health, winners also include the walls of our house (CLIMAFON spells the end to the blackening of walls typical of radiator systems).

Greater security: CLIMAFON's outer surface reaches a top temperature of 43°C, a value that is totally harmless for our body (the risk of burning is nil). Its rounded form without sharp edges makes the room a safer environment especially for children.

Greater care to appearance: the soft flowing, modern and elegant lines give CLIMAFON greater appeal that enables it to be integrated with all types of furnishing whether it is traditional or modern.

Energy saving: the innovative finned exchanger ensures high energy efficiency thanks the possibility of effective use at low temperatures of the warm supply water.

Easier and faster installation: CLIMAFON is much lighter than a radiator with the same capacity; just one person is needed to handle and install it quickly and easily on all types of wall. CLIMAFON is fitted with an installation template that means the unit can be assembled after the building work has been completed. Costly masonry work typical of radiator installation is avoided: just four blocks are required for fixing CLIMAFON to the wall.

84

Versions

• Available in four sizes Flat grid, fixed with aluminum fins.

• The versions available are double (4 rows of pipes) or treble (6 rows of pipes). Water connections can be reversed during installation phase

Selection

By combining the various options, each model can be configured.

Code:

CLIMAFON

Size :

1, 2, 3, 4

Coil :

2 - Double

3 - Treble

Commercial code example: CLIMAFON 23P

Grille:

P - Flat grid, fixed with aluminum fins

Technical data

Mod. CLIMAFON

Heating capacity

Water flow rate

Water pressure drop

Water contents

Coil connections

Rows of pipes

W l/h kPa l

ø

ø

12P

910

78

0,22

0,5

1/2”

2

13P

1005

87

0,26

0,6

1/2”

3

22P

1350

116

0,50

0,8

1/2”

2

23P

1540

135

0,72

1,1

1/2”

3

Heating (in accordance with UNI EN 442):

– room air temperature 20 °C; hot water temperature (in/out) 75/65°C; DT water 50 °C

32P

1750

150

0,95

1,0

1/2”

2

33P

2001

176

1,36

1,4

1/2”

3

42P

2205

190

1,31

1,1

1/2”

2

43P

2515

221

1,91

1,6

1/2”

3

Dimensions (mm)

B

C

A

Mod. CLIMAFON

Height

Width

Depth

Weight

12P 13P 22P 23P 32P 33P 42P 43P

A mm 630 630 630 630 630 630 630 630

B mm 600 600 800 800 1000 1000 1200 1200

C mm 140 140 140 140 140 140 140 140 kg 12 13 15 16 18 19 21 22

All specifications are subject to change without prior notice.

Although every effort has been made to ensure accuracy, Aermec does not assume responsibility or liability for eventual errors or omissions

Aermec S.p.A.

Via Roma, 996 - 37040 Bevilacqua (VR) - Italy

Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577 www.aermec.com

85

Climabox

Recessed wall-mounted convection heater

Climabox is the innovative built-in wall convection radiator for heating systems. It was created to meet the needs for space rationalization according to modern architecture criteria for interiors and the current need for energy saving.

Characteristics

• Available in 3 sizes with double or triple battery.

Climabox consists of several parts to be assembled:

1. Frame in galvanized and painted plate that allows the heat exchanger to be installed in the wall.

2. Heat exchanger

, designed for maximum intensification of the natural convection effect, constructed of copper piping and fining.

3. Closing panel

supplied, which allows the materials, desired look and colour of the panel to be customized. Once the work is complete, the heating unit will be completely hidden from view.

4. Head

Located on the upper horizontal part of the panel, it is available with a fixed metallic grille.

The closing panel and all of the visible parts of the frame are treated so they can be painted with the same paint as the wall.

The Climabox convection heater is the ideal terminal for heating any room. Heat is supplied instantly and uniformly distributed throughout the area.

It can be added to a heating system powered by a boiler, district heating system or heat pump.

The possibility of easily removing the cover allows for thorough cleaning of the interior.

Ease of installation with reversable water attachments in the installation phase. Full compliance with safety and injury prevention regulations

Head closing panel

Frame in galvanized plate

Heat exchange battery

Unit choice

Any model can be configured by changing the available options.

Logo:

CLIMABOX

Size:

2, 3, 4

86

Battery:

2 - Double

3 - Triple

Grille:

Fixed grille

advertisement

Key Features

  • Vertical and horizontal installation
  • Quiet operation
  • Adjustable air delivery louver
  • Electronic temperature control
  • Water connections reversibility
  • Low pressure drop
  • Easy installation and maintenance
  • Full compliance with safety regulations
  • Inverter Brushless motor
  • Energy saving

Frequently Answers and Questions

What are the available sizes for FCX A model?
FCX A is available in sizes 17, 22, 24, 32, 34, 36, 42, 44, 50, 54, 56, 62, 64, 82, 84, and 102.
What accessories are compatible with Omnia HL model?
Omnia HL is compatible with FMT10, FMT21, PX2, PX2C6, PXAE, TPF, WMT05, WMT10, VMF-E4, VMF-E4D, VMF-E2H, VMF-E0, VMF-E1, AMP 10, BC10, BC20, DSC5, PCH/PCHM, SIT3, SIT5, SW3, SWA, VCH, VCHD, ZH1/ZH1B, and ZH1M/ZH1MB.
What's the main difference between FCX and FCXI fan coils?
The main difference between FCX and FCXI fan coils is that FCXI models feature Brushless Inverter motors (EC) for energy savings and quieter operation.

Related manuals

Download PDF