- Home
- Domestic appliances
- Climate control
- Heat pumps
- Aermec
- Omnia HL HL, HL M, HL N, HL NM, HL L, HL LM, HL PC, HL PCM, HL S, HL SM
- User manual
User manual | Aermec FCX A, AS, ACT, APC, B, U, UA, UE, FCXI AS, U, ACT, Omnia HL HL, HL M, HL N, HL NM, HL L, HL LM, HL PC, HL PCM, HL S, HL SM Fan Coils, DUALJET Fan Coil Product Details 75 Pages
User manual | Aermec FCX A, AS, ACT, APC, B, U, UA, UE, FCXI AS, U, ACT, Omnia HL HL, HL M, HL N, HL NM, HL L, HL LM, HL PC, HL PCM, HL S, HL SM Fan Coils, DUALJET Fan Coil Product Details
The FCX A, FCX AS, FCX ACT, FCX APC, FCX B, FCX U, FCX UA, FCX UE Fan Coils are designed to maintain the set temperature over time, ensuring very low sound levels. The FCXI AS, FCXI U, FCXI ACT Fan Coils are equipped with inverter Brushless motor for high efficiency and continuous air flow rate modulation to increase comfort and save energy. The DUALJET Fan Coil makes rooms more comfortable by directing air to provide uniform temperature distribution throughout. The Omnia HL, Omnia HL M, Omnia HL N, Omnia HL NM, Omnia HL L, Omnia HL LM, Omnia HL PC, Omnia HL PCM, Omnia HL S, Omnia HL SM Fan Coils are for both horizontal and vertical installations.
advertisement
FCX
Fan coils
Universal and floor installation
Aermec
participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com
FCX_A housing: RAL 9002 head and feet: RAL 7044
ZX
FCX-U
Features
Fan coils for heating, cooling, and dehumidifying.
FCX is designed to maintain in time the set temperature, ensuring very low sound levels. Installed in any type of plant
2/4 tubes and in combination with any of the heat generator even at low temperatures.
Thanks to the availability of different versions, with front or lower air intake, with standard battery or increased, for horizontal or vertical installation, it is easy to choose the optimal solution for any need.
- Vertical installation:
FCX-A: vertical free-standing with switch
FCX-AS: vertical free-standing without switch. Compatible with the VMF system
FCX-ACT: vertical free standing with electronic thermostat
FCX-APC: (FCX 22, 24, 32, 34, 36, 42, 44, 50, 54, 56, 62,
64, 82, 84) vertical free-standing with electronic thermostat and Plasmacluster purifier
FCX-B: front suction, without selector. Compatible with the VMF system
- Vertical and horizontal installation:
FCX-U: universal floor or wall/ceiling mounting.
Adjustable air distribution grille, except for models 62,
64, 82, 84 and 102. Compatible with the VMF system
FCX-UA: universal floor or wall/ceiling mounting. Grille with fixed fins. Compatible with the VMF system
FCX-UE: universal floor or wall/ceiling mounting with direct expansion coil. Adjustable air distribution grille, except for models 62, 82 and 102.
• Versions standar coil (FCX 17, 22, 32, 36, 42, 50, 56, 62,
82 and 102)
• Versions increased coil (FCX 24, 34, 44, 54, 64, and 84)
• 3-speed ventilating unit
• Full compliance with the accident prevention standards
• Rounded line
• Automatic fan coil switch-off with closure of the air distribution grille
• Broad range of controls
• Metallic protective cabinet with rustproofing polyester paint
• Quiet operation
• Low loss of charge in the heat exchange batteries
• Electric motors with permanently inserted condensers
• Ease of installation and maintenance
• Air filter easy to remove and clean
• Extractable shrouds for easy, effective cleaning
• Water connections can be reversed during installation phase
VERSION
FCX A
FCX AS
FCX ACT
FCX APC
17
17
17
-
22
22
22
22
24
24
24
24
32
32
32
32
34
34
34
34
36
36
36
36
42
42
42
42
AVAILABLE SIZES
44 50
44
44
44
50
50
50
54
54
54
54
56
56
56
56
62
62
62
62
64
64
64
64
82
82
82
82
84
84
84
84
102
102
102
-
FCX B
17 22 24 32 34 36 42 44 50 54 56 62 64 82 84 102
FCX U
FCX UA
FCX UE
Accessories
17
17
-
22
22
22
24
24
-
32
32
32
34
34
-
36
36
-
42
42
42
44
44
-
50
50
50
54
54
-
56
56
-
62
-
62
64
-
-
82
-
82
84
-
-
102
-
102
• AMP: kit for the wall mounting installation of versions FCX U and UE.
• BC: Auxiliary condensate drip tray. Use the BC 5-6 tray accessory if horizontal, or BC 4 if vertical.
• BV: Single row hot water coil. Not available for
4-row versions or those with Plasmacluster.
• DSC4: Condensate drainage device for use when natural run-off is not possible.
• PC: Sheet metal panel to close rear of unit.
• RX: Armoured electric coil with safety thermostat. (Requires a thermostat with heater management). Not available for 4-row versions or those with Plasmacluster.
• SE: Manually operated fresh air intake louver.
• SIT 3 - 5: Thermostat Interface Cards. They allow the creation of a network of fan coils (max. 10) commanded by a central control panel (selector or thermostat).
SIT3: commands the 3 fan speeds and must be installed on each fan coil of the network; receives the commands from the selector or the
SIT5 card.
SIT5: commands the 3 fan speeds and up to 2 valves (four pipes systems); sends the commands of the thermostat to the fan coils network.
• SW3: water temperature probe that gives the automatic season change feature to electronic thermostats supplied with water-side change over.
• SWA: SWA external probe accessory (length L =
6m). The probe detects the temperature of the ambient air if connected to the connector (A) of the panel FMT21; the ambient air temperature probe incorporated in the panel is automatically deactivated. Detects the temperature of the water in the system, for ventilation consent, if connected to the connector (W) of the FMT21 panel. Two SWA probes can be connected to the panel FMT21 simultaneously.
• VCF: the kit contains a motorised 3-way valve with insulating shell, plus coupling and pipes in insulated copper. For 3/4-row and 1-row coils (BV). Combine the SW3 probe with FCX ACT, too. Versions with
230V and 24V~50Hz power supply.
• VCFD: Kit consisting of powered 2-way valve, copper couplings and pipes. For 3/4-row and
1-row coils (BV). Combine the SW3 probe with
FCX ACT, too. Versions with 230V and
24V~50Hz power supply.
• VCF_X4: The valve kits are designed for fan coil units with single coil, installed in a 4 pipe system with the "Cooling" and "Heating" circuits totally separated. The kit consists of 2 valves of
3-way 4 port connection complete with electrothermal actuators, insulating shells for the valves and associated hydraulic piping. VCF1X4L Valve kit for left hand connection fan coil units.
VCF1X4R Valve kit for right hand connection fan coil units. Power supply: 230V ~ 50Hz.
• ZX: Feet for floor-standing installations for A-AS-
ACT-APC models.
• Control panels(1) and VMF System(2): the characteristics are described on the appropriate card.
12
Accessories Size
17 22 24 32 34 36 42 44 50 54 56 62 64 82 84 102
PC
RX
SE
SIT
32
33
42
43
17
18
22
23
62
17
22
32
42
52
3
5
62
15X
20X
30X
40X
80X
FMT10 • FMT21
KTLM
PTI
PX • PX2 • PX2C6
PXBI• PXAI
(1)
(1)
(1)
(1) (3)
(1)
PXAE
PXAR
TF1
(1)
(1)
(1)
TPF
(1)
WMT05• WMT06 • WMT10
(1)
VMF-E4 • VMF-E4D
VMF-E2
VMF-E0 • VMF-E1
AMP
AMP20
BC
BV
4
5
6
117
122
132
142
162
DSC4
(2)
(2)
(2)
(4)
(4)
(4)
(4)
(4)
(5)(6)
(4)
(4)
(4)
(4)
(4)
(4)
SW3
SWA
VCF
VCFD
ZX
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
1X4L - 1X4R
(7)
2X4L - 2X4R
(7)
3X4L - 3X4R
(7)
41-4124
(7)(8)
(7)(8)
42-4224
43-4324
44-4424
(7)(8)
•
•
(7)(8)(9) •
45-4524
1-124
2-224
(7)(8)(9)
(7)(8)
(7)(8)
•
5
6
3-324
4-424
(7)(8)
(7)(8)(9) •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Versions
A-AS-ACT-APC-B-UA
U-UE
A-AS-ACT-APC-B-UA
U-UE
A-AS-ACT-B-U-UA-UE
AS-B-U-UA
AS-B-U-UA-UE
AS-B-U-UA-UE
AS-B-U-UA-UE
AS-B-U-UA-UE
AS-B-U-UA-UE
A-AS-ACT-APC
A-AS-ACT-APC
A-AS-ACT-APC
A-AS-ACT-APC
A-AS-ACT-APC
AS-B-U-UA-UE
AS-B-U-UA-UE
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-ACT-APC-B-U-UA
AS-ACT-APC-B-U-UA
AS-ACT-APC-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-ACT-APC-B-U-UA
AS-ACT-APC-B-U-UA
AS-ACT-APC-B-U-UA
AS-B-U-UA
A-AS-ACT-APC
A-AS-ACT-APC
AS-B-U-UA
AS-B-U-UA
AS-B-UA-U(62 - 102)
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-B-U-UA
AS-B-UA-U(62 - 102)
AS-B-U-UA
U-UA-UE
U-UA-UE
A-AS-ACT-APC-B-U-UA-UE
U-UA-UE
U-UA-UE
A-AS-B-U-UA-UE
A-AS-B-U-UA-UE
A-AS-B-U-UA-UE
A-AS-B-U-UA-UE
A-AS-B-U-UA-UE
A-AS-ACT-APC-B-U-UA-UE
A-AS-ACT-APC-B-UA
U-UE
A-AS-ACT-APC-B-UA
U-UE
(1)(2) The characteristics are described on the appropriate card.
(3) PX2C6, PX2 panel in multiple 6-piece pack.
(4) Accessoires is not available in the model with Plasmacluster filter
(5) The DSC4 accessory is not compatible with AMP and BC4_5_6 accessories
(6) DSC4 and accessoires VMF-system tray cannot be installed together on a single fan coil.
(7) The VCF/VCFD valve and the BC4 tray cannot be installed together on a single fan coil.
(8) = VCF4124-4224-4324-4424-4524 / VCFD124-224-324-424 they are 24V
(9) Only for the BV 1-row coil accessory.
13
Technical data
Mod.
FCX Vel.
17 22 24 32 34 36 42 44 50 54 56 62 64 82 84 102
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1) W H 2296 2960 3912 5354 5964 6413 6618 8600 8191 10100 9648 12919 14300 15140 17100 17019
Heating capacity (70°C)
Water flow rate
Pressure drop
Heating capacity (50°C)
Water flow rate
Pressure drop
(1)
(1)
(1)
(1)
(2)
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2) l/h kPa kPa kPa
W
W
W l/h l/h
W
W l/h l/h l/h kPa kPa kPa
M 2033 2531 3103 4065 4801 4983 5521 6930 7529 8759 8434 10942 11501 13349 14421 15242
L 1686 1906 2097 3165 3728 4188 4062 5200 5021 6241 6056 8327 8499 10771 11198 12558
H
M
201
178
260
222
343
272
470
357
523
421
563
437
581
484
754
608
718
660
886
768
846
740
1133 1254 1328 1500 1493
960 1009 1171 1295 1337
L
H
148 167 184 278 327 367 356 456 440 547 531 730 745 945 982 1101
3 6 4 20 11 13 15 22 15 23 42 17 23 21 32 43
M
L
2
1
4
3
3
1
12
8
7
5
10
8
11
6
15
9
13
6
18
9
33
19
12
7
16
9
16
11
23
15
34
24
H 1360 1770 2320 3160 3550 3800 3960 4950 4870 6100 5380 7500 8400 7960 10200 10000
M
L
L
H
M 1200 1510 1840 2400 2860 2950 3300 4140 4480 5220 4840 6430 6800 6860 8600 9000
L 990 1130 1250 2060 2220 2480 2430 3170 3000 3700 3680 4880 5040 5200 6700 7440
H
M
172
144
258
210
298
236
413
316
482
392
482
370
585
478
765
617
721
604
855
743
791
662
836
752
1092 1189 1479 1311
896 860 1259 1183
112 144 174 267 303 311 397 463 432 533 475 554 674 738 992 979
2 6 3 16 9 9 15 23 15 22 22 9 18 21 31 33
2
1
5
2
2
1
10
7
7
4
7
6
13
8
15
9
11
6
17
9
20
15
7
4
13
8
12
9
23
15
27
19
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
Heating capacity (70°C)
Water flow rate
Pressure drop
(3)
(3)
(3)
(3)
(3)
(3) l/h
(3) kPa
(3)
W
W
W l/h l/h kPa
H
M
L
H
M
L
H
M
1400
1200
990
123
105
87
3
2
1770
1510
1130
155
132
99
6
5
-
-
-
-
-
-
-
-
2850
2450
2030
250
215
178
16
12
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3460
3410
2660
303
299
233
21
20
-
-
-
-
-
-
-
-
4380
3940
3220
384
346
282
35
30
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
5490
4700
3870
482
412
339
16
12
-
-
-
-
-
-
-
-
6410
6300
5300
562
553
465
15
14
-
-
-
-
-
-
-
-
6810
6230
5430
(3) kPa L 2
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
Total cooling capacity
(4)
(4)
W
W
H
M
1000
840
3
1500
1220
-
1730
1370
8
2400
1840
-
2800
2280
-
2800
2150
14
3400
2780
-
4450
3590
21
4190
3510
-
4970
4320
-
4600
3850
10
4860
4370
-
6350
5210
11
6910
5000
-
8600
7320
13
7620
6880
597
547
476
19
16
Sensible cooling capacity
Water flow rate
Pressure drop
Air flow rate
Fans
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
W
W
W
W l/h l/h l/h kPa kPa kPa m
3
/h m
3
/h m
3
/h type
L
H
M
L
H
M
L
H
M
L
H
M
L
650 840 1010 1550 1760 1810 2310 2690 2510 3100 2760 3220 3920 4290 5770 5690
830 1240 1380 1900 2130 2200 2760 3300 3000 3540 3500 3980 5030 5680 5780 5530
690 1000 1090 1570 1720 1820 2110 2640 2540 3060 3070 3300 4100 3780 4870 5350
510
172
144
112
3
2
1
200
160
110
670
258
210
144
6
5
3
290
220
140
760
298
236
174
3
2
1
290
220
140
1110
413
316
267
28
17
13
450
350
260
1250
482
392
303
14
10
6
450
350
260
1280
482
370
311
28
17
13
450
350
260
1630
585
478
397
14
10
7
600
460
330
1960
765
617
463
40
27
16
600
460
330
1790
721
604
432
19
14
8
720
600
400 centrifugal
2170
855
743
533
26
21
12
720
600
400
2120
791
662
475
38
28
15
720
600
400
2440
836
752
554
17
14
8
920
720
520
3060
1092
896
674
13
9
6
720
520
2970
1189
860
738
22
12
9
2800
1479
1259
4420
1311
1183
920 1140 1140 1300
930
700
992
30
22
15
930
700
979
37
31
22
1120
900
Absorbed power
Max. input current
Sound power level
Sound pressure level
Water content
Coil connections
(5)
(5)
(5)
(6)
(6)
(6) n°
W
W
W
(A) dB(A) dB(A) dB(A) dB(A) dB(A) l dB(A)
ø (4R)
ø (3R)
ø (1R)
H
M
L
H
M
L
H
M
L
H
45
38
31
37
30
1
35
29
19
1
25
22
19
1
33
29
25
2
44
33
25
2
44
34
28
2
44
33
25
2
57
43
30
2
57
43
30
2
67
46
34
2
76
52
38
2
76
52
38
3
82
61
40
3
91
60
38
3
106
80
59
3
106
80
59
3
131
100
80
0,16 0,12 0,25 0,21 0,45 0,21 0,28 0,51 0,35 0,36 0,35 0,40 0,48 0,49 0,62 0,58
50
43
31
42
35
51
46
35
43
38
48
41
34
40
33
48
41
36
40
33
48
41
34
40
33
51
44
37
43
36
55
50
41
47
42
56
51
42
48
43
56
53
44
48
45
56
51
42
48
43
57
51
42
49
43
57
51
44
49
43
61
56
51
53
48
61
57
51
53
49
66
61
56
58
53
23
0,6
-
1/2"
23
0,8
-
1/2"
1/2" 1/2"
V3 V3
27
1,0
3/4"
-
-
V3
26
1,1
-
1/2"
1/2"
V3
28
1,5
3/4"
-
-
V3
26
1,5
-
3/4"
1/2"
V3
29
1,5
-
3/4"
1/2"
V3
33
1,9
3/4"
-
-
V3
34
1,5
-
3/4"
1/2"
V3
36
1,9
3/4"
-
-
V3
34
1,9
-
3/4"
1/2"
V3
34
2,5
-
3/4"
1/2"
V3
36
3,4
3/4"
-
-
V3
43
2,5
-
3/4"
1/2"
V3
43
3,4
3/4"
-
-
V3
48
2,5
-
3/4"
1/2"
V3
Speed connected
M
L
V2
V1
V2
V1
V2
V1
V2
V1
V2
V1
V2
V1
V2
V1
V2
V1
V2
V1
V2
V1
V2
V1
V2
V1
V2
V1
V2
V1
V2
V1
V2
V1
Power supply
230V/1/50Hz
H max. speed; M med. speed; L min. speed
Heating mode
2 pipes system configuration
(1) Room air temperature 20°C b.s.; Inlet water temperare 70°C; ΔT water 10°C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20°C b.s.; Inlet water temperare 50°C; Water flow rate as in cooling mode
4 pipes system configuration (with additional heat exchanger) (EUROVENT)
(3)Room air temperature 20°C b.s.; Inlet water temperare 70°C; ΔT water 10°C
Cooling mode (EUROVENT)
(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperare 7°C; DT water 5°C
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(6) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com
14
Dimensions and Weight
B
C
B
C
B C
A
A
A
D
ZX accessoires
(standard and increased coil)
FCX_A
FCX_AS
FCX_ACT
FCX_APC
Mod FCX (A - AS - ACT - APC)
Height with feet
Width depth
Feet height
Weight (without feet)
Mod FCX (U - UE)
Height
Width depth
Weight
Mod FCX (UA)
Height
Width depth
Weight
Mod FCX (B)
Height
Width depth
Weight
FCX_U 17-22-32-36-42-50-56 (standard coil)
FCX_U 24-34-44-54 (increased coil)
FCX_UE 22-32-42-50 (standard coil)
A mm
B mm
C mm
D mm kg
A mm
B mm
C mm kg
A mm
B mm
C mm kg
A mm
B mm
C mm kg
17
563
640
220
105
13
17
520
640
220
13
17
490
640
220
13
17
490
640
220
13
22 / 24
563
750
220
105
15
22 / 24
520
750
220
15
22 / 24
490
750
220
15
22 / 24
490
750
220
15
32/34/36
563
980
220
105
20
32/34/36
520
980
220
20
32/34/36
490
980
220
20
32/34/36
490
980
220
20
42/44
563
1200
220
105
24
42/44
520
1200
220
24
42/44
490
1200
220
24
42/44
490
1200
220
24
FCX_B
FCX_UA 17-22-32-36-42-50-56 (standard coil)
FCX_UA 24-34-44-54 (increased coil)
FCX_U 62-82-102 (standard coil)
FCX_U 64-84 (increased coil)
FCX_U 62-82-102 (standard coil)
50/54/56
563
1200
220
105
24
50/54/56
520
1200
220
24
50/54/56
490
1200
220
24
50/54/56
490
1200
220
24
62 / 64
590
1320
220
34
62/64
688
1320
220
125
34
62/64
590
1320
220
34
82/84
688
1320
220
125
34
82/84
590
1320
220
34
82 / 84
590
1320
220
34
102
590
1320
220
34
102
688
1320
220
125
34
102
590
1320
220
34
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Telephone 0442633111 - Telefax 044293577 www.aermec.com
15
FCXI
Fan coils with Brushless Inverter motor (EC)
Universal and floor installation
Aermec
participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com
FCXI A housing: RAL 9002 head and feet: RAL 7044
FCXI U
• ENERGY SAVINGS OF 50% COMPARED WITH A FAN
COIL WITH TRADITIONAL 3-SPEED MOTOR
• VERY QUIET OPERATION
• TOTAL COMFORT: REDUCED TEMPERATURE AND
HUMIDITY VARIATIONS IN THE AIR-CONDITIONED
ROOMS
Characteristics
Fan coils with with inverter technology, for heating, cooling and dehumidifying, specific to work in sensible environment.
Equipped with inverter Brushless motor for an high effciency and a continuos air flow rate modulation in order to increased comfort and guarantee electric saving. The inverter motor allows a better air temperature regulation on based on the real indoor envirorement requirements without temperature swinging..
The FCXI are the ideal solution for 2/4-pipe systems and for tertiary and commercial installations.
Thanks to the availability of different versions, with front or lower air intake, with standard battery or increased, for horizontal or vertical installation, it is easy to choose the optimal solution for any need.
Versions:
FCXI AS: with tall cabinet
FCXI U: with universal cabinet for floor/ ceiling installation
FCXI ACT: vertical free standing with electronic thermostat
• Fan unit with Brushless motor (continuous 0-100% speed variation)
• Full compliance with the accident prevention standards
• Rounded line
• Metallic protective cabinet with rustproofing polyester paint
• Adjustable air distribution grille, for U versions
• Fan coil automatic power-off function with closure of the air delivery grille, for U versions
• Quiet operation
• Low loss of charge in the heat exchange batteries
• Ease of installation and maintenance
• Air filter easy to remove and clean
• Extractable shrouds for easy, effective cleaning
• Water connections can be reversed during installation phase
Accessories
• WMT21: Control panel with electronic thermostat and LCD monitor. Wall mounting.
• PTI2: Control panel with electronic thermostat on the fan coil installation.
• VMF System: the characteristics are described on the appropriate card.
• AMP: Kit for ceiling installation, for versions
FCXI U.
• BC: Auxiliary condensate drip tray.
• BV: 1-row hot water coil.
The accessory is not available for the 4R models.
• DSC4: Condensate drainage device for use when natural run-off is not possible.
• MA: A-type covering cabinet (use tray accessory
BC 4 for FCXI AS, ACT).
• MU: U-type covering cabinet (use tray accessory
BC 5-6 for FCXI U).
• PC: Sheet metal panel to close rear of unit.
• SE: External air damper with command, FCXI AS and ACT.
• SWAI: Water temperature probe for WMT21 control panels. Cable length L = 2m.
• VMF-SW1: Additional water sensor may be used for 4-pipe system with VMF-E1 and E18 thermostats for the maximum control in the cold range
• VCF: Kit comprising motorized 3 way valve with isolating shell, unions and insulated copper pipes.
For 3/4-row and 1-row coils (BV). Versions with
230V and 24V~50Hz power supply.
• VCFD: Kit consisting of powered 2-way valve, copper couplings and pipes. For 3/4-row and
1-row coils (BV).
• VCF_X4: The valve kits are designed for fan coil units with single coil, installed in a 4 pipe system with the "Cooling" and "Heating" circuits totally separated. The kit consists of 2 valves of 3-way 4 port connection complete with electro-thermal actuators, insulating shells for the valves and associated hydraulic piping. VCF1X4L Valve kit for left hand connection fan coil units. VCF1X4R Valve kit for right hand connection fan coil units. Power supply: 230V ~ 50Hz.
• ZX: Feet for floor installations for FCXI AS and ACT models.
16
Accessories
WMT21
SWAI
VMF-SW1
PTI2
VMF-E18
VMF-E2
VMF-E2D
VMF-E4 / E4D
VMF-E5N / B
AMP
AMP20
BC
BV
4
5
6
122
132
142
162
DSC4
PC
SE
33
42
43
62
22
23
32
20X
30X
40X
80X
1X4L o R
2X4L o R
3X4L o R
VCF
VCFD
ZX
5
6
41 - 4124
42 - 4224
43 - 4324
44 - 4424
45 - 4524
1 - 124
2 - 224
3 - 324
4 - 424
(1)(2)
•
•
(3)
(3)
(3)
(3)(4)
•
•
(3)(4)
(3)(4)
(3)(4)(5) •
(3)(4)
(3)
(3)
(3)
(3)(5)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
20
•
•
24
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
30
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
34
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
36
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
FCXI
•
•
40
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
44
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
50
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
(1)The DSC4 is not compatible with BC4_5_6_8_9 AMP and accessories. The DSC4 accessory is compatible with AMP20 accessory.
(2) The DSC4 and the VMF-system can not be installed simultaneously on the same fancoil
(3) The BC4 accessory is not available for models fitted with VCF / VCFD valve.
(4) VCF4124-4224-4324-4424-4524 / VCFD124-224-324-424 are 24V
(5) Only for accessory coil BV 1R.
•
•
•
•
•
•
•
•
•
•
54
•
•
•
•
•
•
•
•
•
•
56
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
80
•
•
•
•
•
•
•
•
•
•
•
•
•
•
84
•
•
•
•
•
•
•
•
•
•
•
AS - U
AS - U
AS - U
AS - e 80U-84U
AS - U
AS - U
U
AS - U
AS - U
U
U
AS - ACT
U
U
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - ACT
U
AS - ACT
U
AS - ACT
U
AS - U - ACT
AS - ACT
AS - ACT
AS - ACT
AS - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - U - ACT
AS - ACT
AS - ACT
17
Technical data
Mod.
Sensible cooling capacity
Water flow rate
Pressure drop
Air flow rate
Fans
Absorbed power
Max. input current
Sound power level
Sound pressure level
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(5)
(5)
(5)
(6)
(6)
(6)
FCXI
W
W
W
W l/h l/h l/h kPa kPa kPa m 3 /h m 3 /h m 3 /h type n°
W
W
W
(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)
Vel.
L
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
20 24 30 34 36 40 44 50 54 56 80 84
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
Heating capacity (70°C)
Water flow rate
Pressure drop
Heating capacity (50°C)
Water flow rate
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
W
W
W l/h l/h l/h kPa kPa kPa
W
W
W l/h l/h l/h kPa
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
H
2960 3912 5354 5964 6413 6618 8600 8191 10100 9648 15140 17100
2531 3103 4065 4801 4983 5521 6930 7529 8759 8434 13349 14421
1906 2097 3165 3728 4188 4062 5200 5021 6241 6056 10771 11198
260 343 470 523 563 581 754 718 886 846 1328 1500
222 272 357 421 437 484 608 660 768 740 1171 1295
167
6
4
3
184
4
3
1
278
20
12
8
327
11
7
5
367
13
10
8
356
15
11
6
456
22
15
9
440
15
13
6
547
23
18
9
531
42
33
19
945
21
16
11
982
32
23
15
1.770
2.320
3.160
3.550
3.800
3.960
4.950
4.870
6.100
5.380
7.960
10.200
1.510
1.840
2.400
2.860
2.950
3.300
4.140
4.480
5.220
4.840
6.860
8.600
1.130
1.250
2.060
2.220
2.480
2.430
3.170
3.000
3.700
3.680
5.200
6.700
258 298 413 482 482 585 765 721 855 791 1189 1479
210
144
6
236
174
3
316
267
16
392
303
9
370
311
9
478
397
15
617
463
23
604
432
15
743
533
22
662
475
22
860
738
21
1259
992
31
Pressure drop (2)
(2) kPa kPa
M
L
5
2
2
1
10
7
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
(3) W H
1.770
2.850
Heating capacity (70°C)
Water flow rate
Pressure drop
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
W
W l/h l/h l/h kPa kPa kPa
M
L
H
M
L
H
M
L
1.510
1.130
155
132
99
6
5
3
-
-
-
-
-
-
-
-
2.450
2.030
250
215
178
16
12
8
7
4
-
-
-
-
-
-
-
-
-
7
6
2.850
2.450
3.410
2.030
2.660
250
215
178
16
12
8
13
8
3.460
303
299
233
21
20
14
15
9
-
-
-
-
-
-
-
-
-
11
6
4.380
3.940
3.220
384
346
282
35
30
21
17
9
-
-
-
-
-
-
-
-
-
20
15
4.380
3.940
6.300
3.220
5.300
384
346
282
35
30
21
12
9
6.410
562
553
465
15
14
11
23
15
-
-
-
-
-
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
Total cooling capacity
(4)
(4)
W
W
H
M
1500 1730 2400 2800 2800 3400 4450 4190 4970 4600 6910 8600
1.220
1.370
1.840
2.280
2.150
2.780
3.590
3.510
4.320
3.850
5.000
7.320
-
-
-
-
43
31
42
35
23
1
12
8
5
0,12
50
5,8
5
2,5
290
220
140
840 1010 1550 1760 1810 2310 2690 2510 3100 2760
1240 1380 1900 2130 2200 2760 3300 3000 3540 3500
4290 5770
5680 5780
1.000
1.090
1.570
1.720
1.820
2.110
2.640
2.540
3.060
3.070
3.780
4.870
670 760 1110 1250 1280 1630 1960 1790 2170 2120 2970 2800
258
210
144
298
236
174
413
316
267
482
392
303
482
370
311
585
478
397
765
617
463
721
604
432
855
743
533
791
662
475
1189
860
738
1479
1259
992
3
2
1
290
220
140
1
12
8
5
0,12
51
46
35
43
38
27
28
17
13
450
350
260
2
13
7
4
0,21
48
41
34
40
33
26
13,8
10
6
450
350
260
2
13
7
4
0,21
48
41
36
40
33
28
28
17
12,7
450
350
260
2
13
7
4
0,21
48
41
34
40
33
26
14,3
10
7
600
460
330 centrifugal
2
17
9
6
0,28
51
44
37
43
36
29
40,2
27
16,3
600
460
330
2
17
9
6
0,28
55
50
41
47
42
33
19,3
14
7,6
720
600
400
2
37
20
8
0,35
56
51
42
48
43
34
25,9
21
11,7
720
600
400
2
37
20
8
0,35
56
53
44
48
45
36
38
28
15,1
720
600
400
2
37
20
8
0,35
56
51
42
48
43
34
22
12
9,3
1140
930
700
3
80
40
30
0,49
61
56
51
53
48
43
29,5
22
14,7
1140
930
700
3
80
40
30
0,49
61
57
51
53
49
43
H max. speed; M med. speed; L min. speed
Heating performance
2 pipes system configuration
(1) Room air temperature 20°C b.s.; Inlet water temperare 70°C; ΔT water 10°C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20°C b.s.; Inlet water temperare 50°C; Water flow rate as in cooling mode
4 pipes system configuration (with additional heat exchanger) (EUROVENT)
(3)Room air temperature 20°C b.s.; Inlet water temperare 70°C; ΔT water 10°C
Cooling performance (EUROVENT)
(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperare 7°C; DT water 5°C
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(6) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com
18
Technical data
Mod.
Water content
Coil connections
Work percentage compared to the configuration signal
Power supply l
FCXI
ø (4R)
ø (3R)
ø (1R)
%
%
%
Vel.
H
M
L
20
1
-
1/2"
1/2"
90
84
44
24
1,11
3/4"
-
-
90
84
44
30
1,5
-
1/2"
1/2"
90
84
48
34
1,5
3/4"
-
-
90
84
48
36
1,48
-
3/4"
1/2"
90
84
48
40
1,9
-
3/4"
1/2"
90
82
52
230V/1/50Hz
44
1,48
3/4"
-
-
90
82
52
50
1,9
-
3/4"
1/2"
90
86
60
54
1,9
3/4"
-
-
90
86
60
56
2,52
-
3/4"
1/2"
90
86
60
80
3,4
-
3/4"
1/2"
90
84
45
84
2,52
3/4"
-
-
90
84
45
Dimensions (mm)
B
C
B
C
B C
A
A
D
ZX (accessoires)
(standard coil and augmented)
FCXI_AS
FCXI_ACT
FCXI_U
Mod FCXI (AS - ACT)
Height with feet
Width
Depth
Height of feet
Weight (without feet)
Mod FCXI (U)
Height
Width
Depth
Weight
FCXI_U 20-30-36-40-50-56
FCXI_U 24-34-44-54
(standard coil)
(augmented coil)
A
B
C mm mm mm
D mm kg
A
B
C mm mm mm kg
20 / 24
563
750
220
105
15
20 / 24
520
750
220
15
30 / 34 / 36
563
980
220
105
20
30 / 34 / 36
520
980
220
20
A
40 / 44
563
1200
220
105
24
40 / 44
520
1200
220
24
FCXI_U 80
FCXI_U 84
50 / 54 / 56
563
1200
220
105
24
50 / 54 / 56
520
1200
220
24
(standard coil)
(augmented coil)
80 / 84
688
1320
220
125
34
80 / 84
590
1320
220
34
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577 www.aermec.com
19
DUALJET
Controlled outlet fan coils
Floor installation
Aermec
participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com
White
housing RAL 9002 head and feet RAL 7044
DUALJET: comfort, everywhere
The perception of uneven temperature distribution, especially vertically, is one of the main factors that can drastically reduce occupants' perceived well-being.
The innovative DUALJET fan coil makes the room more comfortable, by directing the air in such a way as to provide uniform temperature distribution throughout the room.
In winter, warm air is directed towards the floor; in the summer, cool air is directed towards the ceiling.
Features
• Controlled outlet fan coils available in 4 sizes:
- Vertical installation:
DUALJET: without control panel but with VMF-
E0 thermostat, ready for installation on the network as a Slave unit or as a single or Master unit if combined with the wired panel accessories VMF-E4 / VMF-E4D or VMF-E2D control panel.
• All units are compatible with the VMF system
When installing a centralized control VMF-E5B /
VMF-E5N or BMS third party will need to contact your
• Switching the front air outlet or from the top, using the selector on the unit.
• Front outlet for heating operation.
• Outlet from the top for cooling operation.
• Versions with 3-row coil
(sizes 20, 30, 40, 50)
• 3-speed ventilating unit
• Full compliance with the accident prevention standards
• Rounded line
• Metallic protective cabinet with rustproofing polyester paint
• Plastic feet available as accessory
• Quiet operation
• Low loss of charge in the heat exchange batteries
• Electric motors with permanently inserted condensers
• Ease of installation and maintenance
• Air filter easy to remove and clean
• Extractable shrouds for easy, effective cleaning
• Water connections can be reversed during installation phase
Accessories
• Control panel and VMF System: The features are described in the dedicated cards.
* VMF-E1D Please contact us.
• ZX: Feet for floor mounting
• VCF: the kit contains a motorised 3-way valve with insulating shell, plus coupling and pipes in insulated copper. For 4-row, 3-row and
1-row coils (BV). Versions with 230V and
24V~50Hz power supply.
• VCFD: Kit consisting of powered 2-way valve, copper couplings and pipes. For 4-row, 3-row and 1-row coils (BV). Versions with 230V and
24V~50Hz power supply.
• VCF_X4: The valve kits are designed for fan coil units with single coil, installed in a 4 pipe system with the "Cooling" and "Heating" circuits totally separated. The kit consists of 2 valves of
3-way 4 port connection complete with electrothermal actuators, insulating shells for the valves and associated hydraulic piping.
VCF1X4L Valve kit for left hand connection fan coil units. VCF1X4R Valve kit for right hand connection fan coil units. Power supply: 230V ~
50Hz.
DUALJET
VMF-E4 • VMF-E4D
VMF-E2D
ZX5
VCF41 • VCF4124
VCF42 • VCF4224
VCFD1 • VCFD124
VCFD2 • VCFD224
VCF1X4L • VCF1X4R
VCF2X4L • VCF2X4R
20
•
•
•
•
•
•
30
•
•
•
•
•
•
•
•
40
•
•
•
•
•
•
50
•
•
•
•
20
Technical data
Mod. DUALJET
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
Heating capacity (70°C)
(1)
(1)
W
W
(1)
(1)
W l/h
Water flow rate
(1)
(1) l/h l/h
Pressure drop
Heating capacity (50°C)
Water flow rate
Pressure drop
(2)
(2)
(2)
(2)
(2)
(2)
(1)
(1)
(1)
(2)
(2)
(2) l/h l/h l/h kPa kPa kPa kPa kPa kPa
W
W
W
cooling PERFORMANCE
Total cooling capacity
Sensible cooling capacity
Water flow rate
Pressure drop
Air flow rate
Fans
Absorbed power
Max. input current
Sound power level
Sound pressure level
Water content
Coil connections
(4)
(4)
(4)
(5)
(5)
(5)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3) kPa kPa m 3 /h m 3 /h m 3 /h type n°
W
W l/h l/h l/h kPa
W
W
W
W
W
W
W
A dB(A) dB(A) dB(A) dB(A) dB(A) l dB(A)
ø
Speed connected
Vel.
M
L
H
M
L
H
H
M
L
H
H
M
L
H
M
L
M
L
M
L
H
M
L
L
H
M
L
H
L
H
H
M
M
H
M
L
H
M
L
H
M
L
H
M
L
20
2960
2531
1906
260
222
167
6
4
3
1770
1510
1130
258
210
144
6
5
2
1500
1220
840
1240
1000
670
258
210
144
5,8
5
2,5
290
220
140
1
25
22
19
0,12
50
43
31
42
35
23
0,79
1/2”
V3
V2
V1
30
5354
4065
3165
470
357
278
20
12
8
3160
2400
2060
413
316
267
16
10
7
2400
1840
1550
1900
1570
1110
413
316
267
28
17
13
450
350
260
0,21
48
41
34
2
44
33
25
40
33
26
1,11
1/2”
V3
V2
V1
Centrifugal
40
9918
5521
4062
581
484
356
15
11
6
3960
3300
2430
585
478
397
15
13
8
3400
2780
2310
2760
2110
1630
585
478
397
14,3
10
7
600
460
330
0,28
51
44
37
2
57
43
30
43
36
29
1,48
3/4”
V3
V2
V1
Power supply
230V/1/50Hz
H max. speed; M med. speed; L min. speed
Heating mode
2 pipes system configuration
(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; DT water 10°C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode
Cooling mode (EUROVENT)
(3) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C
(4) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(5) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com
Dimensions (mm)
C
B
B
C
Mod DUALJET
Height
Height with feet
Widht
Depth
Weight (1)
A mm mm
B mm
C mm
D mm kg
20
520
606
750
220
88
15
(1) Unit in standard configuration without accessories
30
520
606
980
220
88
20
40
520
606
1200
220
88
24
50
520
606
1200
220
88
24
C
B
A
A
C
B
50
4190
3510
2510
3000
2540
1790
721
604
432
19,3
14
7,6
720
600
400
8191
7529
5021
718
660
440
15
13
6
4870
4480
3000
721
604
432
15
11
6
2
67
46
34
0,35
56
51
42
48
43
34
1,48
3/4”
V3
V2
V1
D
D
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577 www.aermec.com
A
A
21
Omnia HL
Fan coils
Universal installations for residential applications
Aermec
participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com
Plasmacluster
(only for Omnia HL PC and PCM)
White colour:
cover: RAL 9002 top and supports: RAL 7044
Grey colour:
cover: FIAT 656 top and supports: RAL 7031
Features
• HL (High Line) fan coils for both horizontal and vertical installation
• 4 sizes and 12 versions:
HL: white body with switch
HL M: metallic grey body with switch
HL N: white body with electronic thermostat VMF
HL NM: metallic grey body with electronic thermostat
VMF
HL L: white cabinet with Self-Closing Louver and electronic thermostat
HL LM: grey cabinet with Self-Closing Louver and electronic thermostat
HL PC: white body with electronic thermostat and Plasmacluster filter (factory-mounted only)
HL PCM: metallic grey body with electronic thermostat and Plasmacluster filter (factorymounted only)
HL S: white body with no on-board controls
VMF System compatible
HL SM: metallic grey body with no on-board controls. VMF System compatible
• 3-speed centrifugal fan
• Very quiet operation
• Aesthetically styled with soft flowing lines
• New adjustable air delivery louver
• Automatic power-off function with closure of the air delivery louver
• Slim dimensions
• Electronic temperature control, automatic fan speed change, automatic season changeover and automatic on - off (with electronic thermostat)
• Water connections reversibility during installation
• Low pressure drop across heat exchanger
• Motors with permanently connected condensers
• Easy installation and maintenance
• Full compliance with safety regulations
Accessories
• AMP: Kit for wall/ceiling mounting. Standard on S and SM versions.
• BC: Auxiliary condensate drip tray.
BC 10 for vertical installation
BC 20 for horizontal installation
• DSC5: Condensate drainage device for use when natural run-off is not possible. DSC5 is not compatible BC10 - BC20 accessories.
• PCH - PCHM: Back closing panel, white
(PCHM) or gray (PCHM).
• SIT 3-5: Thermostat interface cards. They allow to set up a fancoils network (max. 10) commanded by a centralised panel (switch or thermostat).
SIT3: commands the three speeds of the fan and must be installed on each fancoil of the network; it receives the commands from the switch or from the SIT5 card.
SIT5: commands the 3 fan speeds and up to two valves (four-pipe systems); it sends the thermostat commands to the fancoils network.
• SW: Water probe which enables automatic season change-over thanks to the specific electronic thermostats.
• SWA: External probe accessory SWA (length
L=6m). It detects the temperature of the room air if connected to the connector (A) of the
FMT21 panel. The room air temperature probe, incorporated in the panel, is automatically disabled. It detects the temperature of the water in the system for ventilation consent if connected to the connector (W) of the FMT21 panel. Two
SWA probes can be connected simultaneously to the FMT21 panel.
• VCH: Kit comprising motorized 3-way valve, unions and copper pipes.
• VCHD: Kit comprising motorized 2-way valve, unions and copper pipes.
• ZH1: White feet for floor-standing installations
• ZH1B: White feet for floor-standing installations with skirting board.
• ZH1M: Gray feet for floor-standing installations
• ZH1MB: Gray feet for floor-standing installations with skirting board.
• Control panels
(1) and VMF system (2)
: the characteristics of the control panels are described on the appropriate card.
Compatibility of accessories
Omnia HL
FMT10
(1)
•FMT21
PX2
(1)
PXAE
• PX2C6
(1)
(1)
(1)
TPF
(1)
WMT05
VMF-E4
(2)
• VMF-E4D
VMF-E2H
VMF-E0
(1)
• WMT10
(2)
(2)
• VMF-E1
(1)
(2)
(2)
AMP 10
BC10 *
BC20 *
DSC5 *
PCH/PCHM
SIT3
SIT5
SW3
SWA
VCH
VCHD
ZH1/ZH1B
ZH1M/ZH1MB
11 16 26 36 Versions
• • • • S-SM
• • • • S-SM
• • • • S-SM
• • • • S-SM
• • • • S-SM
• • • • S-SM
• • • • S-SM
• • • • S-SM
• • • • All except S, SM
• • • • All
• • • • All
• • • • All
• • • • All
• • • • S-SM
• • • • S-SM
• • • • S-SM
• • • • S-SM
• • • • All except L, LM
• • • • All except L, LM
• • • • All
• • • • All
PX2C6, PX2 panel in multiple 6-piece pack.
* = The DSC5 accessory is not compatible BC10 - BC20 accessories.
Main features
• Versions compatible with VMF System.
• Fan cleaning: Omnia fan coils allow fan blades to be easily cleaned. It is now possible to remove the fan volute (it contains the fan blades) and clean it periodically.
• Condensate drip tray cleaning: Thanks to a new drip tray fitting, it is now easier to clean it with Omnia fan coils. This important solution avoids, in the long run, bacteria, germs and mould to grow up, in the drip tray because of the air humidity.
• Precharged electrostatic filter: Omnia fan coils have, as standard, precharged electrostatic filters. These filters, thanks to their special execution, attracts and retains all suspended dust particles, thus garanteeing pure breathable air to the whole family.
• PLASMACLUSTER ionising filter:
Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them. Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions neutralise the gas pollutant molecules, forming products that are normally present in clean air. The result is in the air: you can finally breath clean, odour-free ionised air.
• Silent operation: Thanks to the use of special centrifugal fans, Omnia fan coils operation is extremely silent and offers the maximum acoustic comfort.
22
Technical data
Mod.
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1) W
Heating capacity (70°C)
(1)
(1)
W
W
Water flow rate
Pressure drop
Heating capacity (50°C)
(1)
(1)
(1)
(1)
(1)
(1)
(2)
(2)
(2)
Water flow rate
(2)
(2) l/h l/h
Pressure drop
(2)
(2)
(2)
(2) l/h kPa kPa kPa
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(3) W
Total cooling capacity
(3)
(3)
W
W
Sensible cooling capacity
Water flow rate
Pressure drop
Air flow rate
Fans
Absorbed power
Max. input current
Sound power level
Sound pressure level
Water content
Coil connections
(5)
(5)
(5)
(4)
(4)
(4)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3) n°
W
W
W
(A) dB(A) dB(A) dB(A)
W
W
W l/h l/h l/h kPa kPa kPa m
3
/h m
3
/h m
3
/h type dB(A) dB(A) l dB(A)
ø l/h l/h l/h kPa kPa kPa
W
W
W
Speed connected
Vel.
M
L
L
H
H
M
M
L
L
H
H
M
L
H
M
H
M
L
M
L
L
H
H
M
L
H
M
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
HL 11
1
1150
870
650
144
117
93
2
1
1
2010
1460
1060
176
128
93
2
1
144
117
93
1,9
1
1
180
120
80
840
680
540
700
530
390
0,09
46
37
31
1
18
12
8
37,5
28,5
22,5
0,4
1/2"
V3
V2
V1
HL 16
1
1700
1250
930
206
153
122
4
2
2
2910
2120
1540
255
186
135
4
2
206
153
122
4,8
3
2
240
160
110
1200
890
710
990
710
540
1
32
25
23
0,15
48
43
34
39,5
34,5
25,5
0,5
1/2"
V3
V2
V1
Centrifugal
HL 26
5
2750
2240
1670
349
289
220
10
7
4
4620
3830
2890
405
336
253
11
8
349
289
220
11
9
5
350
270
190
2030
1680
1280
1640
1330
990
0,18
48
43
35
2
35
27
24
39,5
34,5
26,5
0,8
1/2"
V3
V2
V1
Power supply
230V/1/50Hz
H max. speed; M med. speed; L min. speed
Heating mode
2 pipes system configuration
(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; DT water 10°C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode
Cooling mode (EUROVENT)
(3) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C
(4) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(5) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com
HL 36
487
394
286
18,9
12
7
460
350
240
2830
2290
1660
2040
1620
1160
2
42
35
30
0,22
50
43
34
39,5
32,5
25,5
1,1
1/2"
V3
V2
V1
3
3540
2860
2080
487
394
286
16
11
6
5940
4870
3530
521
427
310
7,7
5,4
Dimensions (mm)
Mod Omnia
Height
Widht
Depth
Height with feet
Weight
A
B
C
D kg
HL 11
600
640
187
93
13,6
HL 16
605
750
189
93
14,6
HL 26
615
980
191
93
17,6
HL 36
623
1200
198
93
20,6
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577 www.aermec.com
23
Omnia UL
Fan coils
Universal installations for residential applications
Aermec
participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com
Plasmacluster
(only for Omnia UL PC)
White colour:
cover: RAL 9002 top and supports: RAL 7044
Features
• UL (Universal Line) fan coils for both horizontal and vertical installation
• Versions:
UL-S: version without switch, with cabinet.
Compatible with VMF System
UL: version with switch and cabinet
UL-C: version with electronic thermostat and with cabinet
UL-PC: version with electronic thermostat and Plasmacluster filter (factory-mounted only) and cabinet
• Versions compatible with VMF System.
• Fan cleaning: Omnia fan coils allow fan blades to be easily cleaned. It is now possible to remove the fan volute (it contains the fan blades) and clean it periodically.
• Condensate drip tray cleaning: Thanks to a new drip tray fitting, it is now easier to clean it with Omnia fan coils. This important solution avoids, in the long run, bacteria, germs and mould to grow up, in the drip tray because of the air humidity.
• Precharged electrostatic filter: Omnia fan coils have, as standard, precharged electrostatic filters. These filters, thanks to their special execution, attracts and retains all suspended dust particles, thus garanteeing pure breathable air to the whole family.
• PLASMACLUSTER ionising filter:
Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them. Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions neutralise the gas pollutant molecules, forming products that are normally present in clean air. The result is in the air: you can finally breath clean, odour-free ionised air.
• Silent operation: Thanks to the use of special centrifugal fans, Omnia fan coils operation is extremely silent and offers the maximum acoustic comfort.
• 3-speed centrifugal fan
• Very quiet operation
• Aesthetically styled with soft flowing lines
• Adjustable air delivery louver
• Automatic power-off function with closure of the air delivery louver
• Slim dimensions
• Electronic temperature control, automatic fan speed change, automatic season changeover and automatic on - off (with electronic thermostat)
• Water connections reversibility during installation
• Low pressure drop across heat exchanger
• Motors with permanently connected condensers
• Easy installation and maintenance
• Air filter easy to remove and to clean
• Full compliance with safety regulations
Accessories
• AMP: Kit for wall/ceiling mounting. Standard on P and S versions.
• BC: Auxiliary condensate drip tray.
BC 10 for vertical installation
BC 20 for horizontal installation
• DSC5: Condensate drainage device for use when natural run-off is not possible. DSC5 is not compatible BC10 - BC20 accessories.
• GU: Aspiration grille, covers the front space between the stands, does not interfere with the air filter. Use with ZU stands compulsory.
• PCU: Rear cover panel.
• SIT 3-5: Thermostat interface cards. They allow to set up a fancoils network (max. 10) commanded by a centralised panel (switch or thermostat).
SIT3: commands the three speeds of the fan and must be installed on each fancoil of the network; it receives the commands from the switch or from the SIT5 card.
SIT5: commands the 3 fan speeds and up to two valves (four-pipe systems); it sends the thermostat commands to the fancoils network.
• SW: Water probe wich enables automatic season change-over thanks to the specific electronic thermostats.
• SWA: External probe accessory SWA (length L
= 6m). It detects the temperature of the room air if connected to the connector (A) of the
FMT21 panel. The room air temperature probe, incorporated in the panel, is automatically disabled. It detects the temperature of the water in the system for ventilation consent if connected to the connector (W) of the
FMT21 panel. Two SWA probes can be connected simultaneously to the FMT21 panel.
• VCH: Kit comprising motorized 3-way valve, unions and copper pipes.
• VCHD: Kit comprising motorized 2-way valve, unions and copper pipes.
• ZU: Feet for floor-standing solutions.
• Control panels and VMF System: The control panels are described in a separate document.
24
Omnia UL_S_C_PC
FMT21
PX2 o PX2C6
PXAE
PXLM
TPF
WMT05
WMT10
VMF-E4 o E4D
VMF-E0 o E1
AMP10
BC10
BC20
DSC5
SIT3
SIT5
SW3
SWA
VCH
VCHD
ZU
(1)
(2)
S
S
S
S
vers.
S
S
S
S
S
UL-C-PC all all all
S
S all
S all all
UL-S-C-PC
11
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
16
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
26
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
36
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
(1) PX2C6, PX2 panel in multiple 6-piece pack.
(2) The DSC5 accessory is not compatible BC10 - BC20 accessories.
Technical data
Mod.
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1) W
Heating capacity (70°C)
(1)
(1)
W
W
Water flow rate
Pressure drop
Heating capacity (50°C)
Water flow rate
Pressure drop
(1)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(1)
(1)
(1)
(1)
(1) kPa
W
W
W l/h l/h l/h kPa kPa kPa l/h l/h l/h kPa kPa
COOLING PERFORMANCE
Total cooling capacity
Sensible cooling capacity
Water flow rate
Pressure drop
Air flow rate
Fans
Absorbed power
Max. input current
Sound power level
Sound pressure level
Water content
Coil connections
(5)
(5)
(5)
(4)
(4)
(4)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3) n°
W
W
W
(A) dB(A) dB(A) dB(A) dB(A) dB(A) l dB(A) l/h l/h l/h kPa kPa kPa m
3
/h m
3
/h m
3
/h type
W
W
W
W
W
W
ø
Speed connected
Vel.
M
L
L
H
H
M
M
L
L
H
H
M
L
H
M
H
M
L
M
L
L
H
H
M
L
H
M
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
UL11
1
1150
870
650
144
117
93
2
1
1
2010
1460
1060
176
128
93
2
1
144
117
93
1,9
1
1
180
120
80
840
680
540
700
530
390
0,09
46
37
31
1
18
12
8
37,5
28,5
22,5
0,4
1/2"
V3
V2
V1
UL16
1
1700
1250
930
206
153
122
4
2
2
2910
2120
1540
255
186
135
4
2
206
153
122
4,8
3
2
240
160
110
1200
890
710
990
710
540
1
32
25
23
0,15
48
43
34
39,5
34,5
25,5
0,5
1/2"
V3
V2
V1
Centrifugal
UL26
5
2750
2240
1670
349
289
220
10
7
4
4620
3830
2890
405
336
253
11
8
349
289
220
11
9
5
350
270
190
2030
1680
1280
1640
1330
990
0,18
48
43
35
2
35
27
24
39,5
34,5
26,5
0,8
1/2"
V3
V2
V1
Power supply
230V/1/50Hz
H max. speed; M med. speed; L min. speed
Heating mode
2 pipes system configuration
(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; DT water 10°C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode
Cooling mode (EUROVENT)
(3) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C
(4) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(5) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com
UL36
487
394
286
18,9
12
7
460
350
240
2830
2290
1660
2040
1620
1160
2
42
35
30
0,22
50
43
34
39,5
32,5
25,5
1,1
1/2"
V3
V2
V1
3
3540
2860
2080
487
394
286
16
11
6
5940
4870
3530
521
427
310
7,7
5,4
Dimensions (mm)
B
Mod Omnia
Height
Widht
Depth
Height with feet
Weight
A
B
C
D kg
UL 11 UL 16 UL 26 UL 36
513 513 513 513
640 750 980 1200
173
93
12,5
173
93
13,5
173
93
16,5
173
93
19,5
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.
A
Wall installation
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293730 www.aermec.com
C
A
D
B
Floor installation
ZU
C
25
Omnia Radiant
Fan coils with radiant panel for residential use
Ceiling or floor mounted
Aermec
participate in the EUROVENT program: FCU the products are present on the site www.eurovent-certification.com
• LOW TEMPERATURE RADIATION*
• VENTILATED HEATING
• COOLING - DEHUMIDIFICATION
• ENERGY SAVING
• LOW OPERATING COST
* Radiant technology under licence
Features
Omnia Radiant and Omnia Radiant Plus
Aermec innovative solutions
In this particular worldwide market evolution, we are pleased to present to you OMNIA
Radiant, which represents the innovation of the
OMNIA AERMEC series, fan coils especially designed for residential comfort.
The four different working modes of Omnia
Radiant annual functioning
Radiant: Heating through radiation, comfortable and noiseless, is granted by the radiant plate placed on the front of the fan coil cover; if necessary, the triple-fins delivery head can be closed to increases the heating of the plate, thus maximizing the radiant effect.
OMNIA Radiant inherits all the advantages of the OMNIA UL series, and is characterized by the introduction of the frontal plate for radiant heating.
OMNIA Radiant Plus is provided with the DC
Brushless electric engine, equipped with the latest Inverter technology, granting the highest energy efficiency and able to regulate the air flow through the continuous fan speed modulation. This allows to achieve up to 60% in energy saving when compared to the traditional On-Off fan system, in both air conditioning and heating.
Radiant + Natural Convection
With the triple-fins open, heating through natural convection, obtained thanks to the bigger coil exchange surface, is added to the radiant heating.
As for the radiant-only mode (see above), the fan groups are in off mode. This results in acoustic comfort and energy saving.
OMNIA Radiant and Radiant Plus offer the following advantages when compared to the traditional systems:
• the radiant plate combination – the finned coil allows the best winter comfort with the lower energy consumption because it provides heating with lower water temperature: only 45°C against the about 65°C needed for the traditional radiator. This not only increases the comfort for the user, but also significantly increases the overall efficiency in case of heat pumps usage;
• the fan system allows to quickly reach the desired temperature, meeting the requirement of a fast start-up;
• the unit can be combined other than the boiler, also to energy saving heat pumps: air to water, water to water and geothermic type;
• the electrostatic charge filter standard supplied, provides pure and clean air;
• during summer Omnia Radiant and Radiant
Plus provide air conditioning and dehumidification in a fast and efficient way in every room.
26
Radiant + Forced Convection
The electronic regulation, precise and reliable, continuously compares the effective indoor temperature with the desired temperature: whenever the difference between the two should prove to be too high (e.g. during the heating system startup) the software will lead the fan system start-up.
Start-up is fast and efficient and grants significant energy savings especially in rooms that are occasionally used.
Omnia Radiant during summer provides air conditioning and dehumidification:
Forced Convection
During summer, Omnia Radiant and Radiant
Plus provide air conditioning and dehumidification for each room of the house in a fast and efficient way. Efficiency and quietness benefit from the quality that has always characterized the
Omnia series.
Radiant
Radiant + Natural Convection
Radiant + Forced Convection
Forced Convection
Features of the Omnia Radiant series
1
2
3
4
Radiant plate
Switching valve
Water probe
Condensate storage container, hydraulic hoses
2
3
1
4
VCHRAD accessory
• OMNIA radiant (UL_R) standard features:
- Radiant panel
- Centrifugal fans
- Three-speed motor
- Condensate storage container, hydraulic hoses
- Switching valve
- Water probe
- Electro-statically preloaded filter
- VMF-thermostat for asynchronous motor
- Compatible with VMF system
• OMNIA radiant plus (UL_RI) standard fea-
tures:
- Radiant panel
- Centrifugal fans
- Electric DC Brushless motor with Inverter
- Condensate storage container, hydraulic hoses
- Water probe
- Switching valve
- Electro-statically preloaded filter
- VMF thermostat for DC Brushless motor
- Compatible with VMF system
Accessories
• PCU: Rear closing panel.
• ZU: Wedges for floor mount.
• GU: Exhaust grille: covers the front space of the wedges and does not interfere with the air filter.
• VCHRAD: Kit comprising motorized 3-way valve, unions and copper pipes.
Must be combined with ZU wedges.
• VMF System:
Its specs are described in its technical sheet.
Cleaning the fan: The fan blades on the
Omnia Radiant are easy to clean. As a matter of fact, the new versions now offer the possibility of opening the worm screw of the fan (the casing that encloses the blades) to perform routine cleaning.
• Electro-statically preloaded filter: The
Omnia Radiant fan coils feature standard air filters that are electro-statically preloaded. These filters, thanks to their particular construction, absorb and trap floating dust: the ideal system to provide clean air for all the family.
• Silent operation: Thanks to special centrifugal fans, Omnia Radiant fan coils are incredibly silent, making them the best buy when it comes to acoustic comfort, given the total lack of peak noise. "The heating by radiation
at top speed ensures total silence regime”
Note:
The coil had hydraulic hoses on the left and is not reversible.
PCU
GU
VCHRAD
ZU
VMF system
VMF-E4 (compulsory accessory)
VMF-E4D (compulsory accessory)
VMF-E5B
VMF-E5N
* Contact us
Omnia radiant
UL26R UL36R
25 35
25
•
•
35
•
•
•
•
*
*
•
•
*
*
Omnia Radiant plus
UL26RI UL36RI
25 35
25
•
•
35
•
•
•
•
•
•
•
•
•
•
27
Technical Data
Mod. UL_R
Heating capacity (70°C)
Heating capacity (50°C)
Water flow rate
Water pressure drop
Static heating power (70°C)
Static heating power (50°C)
Static heating power (35°C)
Total cooling capacity
Sensible cooling capacity
Water flow rate
Water pressure drop
Air flow rate n° Fans
Sound pressure
Sound power
Water contents
Max. motor power
Max. input current
Coil connections (in/out)
Power supply
(1)
W (max.)
W (med.)
W (min.)
(2) W l/h kPa
(3) W
(4) W
(5) W
W (max.)
W (med.)
W (min.)
W (max.)
W (med.)
W (min.) l/h kPa m 3 /h (max.) m 3 /h (med.) m 3 /h (min.) n.
dB (A) (max.) dB (A) (med.) dB (A) (min.) dB (A) (max.) dB (A) (med.) dB (A) (min.) l
W
A
ø (mm)
V/ph/Hz
Mod. UL_RI
Heating capacity (70°C)
Heating capacity (50°C)
Water flow rate
Water pressure drop
Static heating power (70°C)
Static heating power (50°C)
Static heating power (35°C)
Total cooling capacity
Sensible cooling capacity
Water flow rate
Water pressure drop
Air flow rate n° Fans
Sound pressure
Sound power
Water contents
Max. motor power
Max. input current
Coil connections (in/out)
Power supply
(1)
(2)
(3)
(4)
(5)
W (max.)
W (med.)
W (min.)
W l/h kPa
W
W
W
W (max.)
W (med.)
W (min.)
W (max.)
W (med.)
W (min.) l/h kPa m 3 /h (max.) m 3 /h (med.) m 3 /h (min.) n.
dB (A) (max.) dB (A) (med.) dB (A) (min.) dB (A) (max.) dB (A) (med.) dB (A) (min.) l
W
A
ø (mm)
V/ph/Hz
Cooling:
Room temperature 27°C b.s./19°C b.u.; Cold water (in/out) 7°C/12°C
Heating:
(1) Room temperature 20°C b.s.; Hot water (in) 70°C; ΔT 10°C
(2) Room temperature 20°C b.s.; Hot water (in/*) 50°C/*°C (water flow same as in heating cycle)
(3) Radiant power + natural convection; Hot water (in) 70°C (water flow same as in heating cycle)
(4) Radiant power + natural convection; Hot water (in/*) 50°C/*°C (water flow same as in heating cycle)
(5) Radiant power + natural convection; Hot water (in/*) 35°C/*°C (water flow same as in heating cycle)
18
350
270
190
2
39,5
34,5
26,5
48
200
2030
1780
1420
1640
1370
1050
349
26
4620
3830
2890
2750
397
17
650
390
43
35
0,8
12
0,18
14
230V/1/50Hz
26
4620
3830
2890
2750
397
17
650
390
200
270
190
2
39,5
34,5
26,5
48
43
35
2030
1780
1420
1640
1370
1050
349
18
350
0,8
35
0,18
14
230V/1/50Hz
22
460
350
240
2
39,5
32,5
25,5
50
230
2830
2310
1730
2040
1790
1280
487
36
5940
4870
3530
3540
511
21
750
450
41
34
1,1
16
0,22
14
230V/1/50Hz
36
5940
4870
3530
3540
511
21
750
450
230
350
240
2
39,5
32,5
25,5
50
41
34
2830
2310
1730
2040
1790
1280
487
22
460
1,1
42
0,22
14
230V/1/50Hz
Level of sound pressure (A-weighted) measured in the room with volume V = 85m3 ; reverberation time t = 0.5s; direction factor Q = 2; distance r = 2.5m
28
Heating capacity with fan off
UL26R - UL26RI
600
500
400
300
200
100
0
35 40 45 50 55 60 65
Inlet water temperature [°C]
70
UL36R - UL36RI
900
800
700
600
500
400
300
200
100
0
30
16°C
20°C
22°C
26°C
35 40 45 50 55 60 65 70 75
Inlet water temperature [°C]
80
20°C
26°C
Dimensions (mm)
C
B
A
Wall installation
C
B
A
ZU
Mod OMNIA ULR - ULRI
Height
Width
Depth
Height with ZU (Accessories)
Weight (1)
A
B
C
D
(1) Standard configuration of unit with accessories
(mm)
(mm)
(mm)
(mm)
(kg)
26
606
980
173
93
20
D
Floor installation
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577 www.aermec.com
36
606
1200
173
93
24
29
FCX P
Fan coils
Duct installation
Aermec
participate in the EUROVENT program: FCU the products are present on the site www.eurovent-certification.com
Features
Vertical and horizontal installation:
FCX P: Duct installation without cabinet
FCX PPC: Duct installation without cabinet, with
Plasmacluster purifier. Compatible with the VMF system, or you can request a combination with the
PXAE control panel
FCX PE: Duct installation without cabinet and with direct expansion coil
FCX PO: with boosted motor
6-speed (3 of which can be selected) up 22 to 82
7-speed (3 of which can be selected) up 62 to 82
FCX PBV: with 3 row coil +1 in a single shoulder, standard connections (left)
FCX PBVD: with 3 row coil +1 in a single shoulder, standard connections (right)
FCX POBV: boosted and with 3 row coil +1 in a single shoulder, standard connections (left)
FCX POBVD: boosted and with 3 row coil +1 in a single shoulder, standard connections (right)
For versions with 3 row +1 battery, the battery is not reversible specify the side of the attacks
at the time of the order.
- Vertical installation:
FCX PV: Duct installation without cabinet
• Versions with 3/4-row coil
• 3-speed ventilating unit
• Compatible with the VMF system
• Wide range of controls and accessories
• Quiet operation
• Low loss of charge in batteries
• Electric motors with permanently inserted condensers
• Ease of installation and maintenance
• Air filter easy to remove and clean
• Possibility of a residual head for ducting (if required)
• Internal insulation and air filter in fire resistance class 1
• Extractable shrouds for easy, effective cleaning
• Water connections can be reversed during installation phase
VERSION
FCX_P
FCX_PV
FCX_PO
FCX_PE
FCX_PPC
FCX_PBV
FCX_PBVD
FCX_POBV
FCX_POBVD
Accessories
17
-
-
17
17
-
-
17
-
22
22
22
22
22
22
22
22
22
32
32
32
32
32
32
32
32
32
Versions with 3 row coil
36 42 50 56
36
36
36
36
36
36
-
36
42
42
42
42
42
42
42
42
50
50
50
50
50
50
50
50
56
56
56
56
56
56
-
56
AVAILABLE SIZES
62
62
62
62
62
62
62
62
62
82
82
82
82
82
82
82
82
82
102
102
-
102
-
102
102
-
-
24
-
-
-
-
24
24
-
24
34
Versions with 4 row coil
44 54 64
-
-
-
-
34
34
-
34
-
-
-
-
44
44
-
44
-
-
-
-
54
54
-
54
-
-
-
-
64
64
-
64
84
-
-
-
-
84
84
-
84
• AMP: Kit for overhang installation.
• BC: Auxiliary condensate drip tray.
• BV: 1-row hot water coil. Not available for
4-row versions or those with Plasmacluster.
When mounted in place, you must specify the con-
nection side
• CHF:VentilCassaforma is a galvanised metal template that allows you to create a space directly in the wall for housing the fan coil. (For
FCX P - PV only).
• DSC4: Condensate drainage device for use when natural run-off is not possible.
• GA: Intake grille with fixed fins.
• GAF: Intake grille with fixed fins and filter.
• GM: Delivery grille with adjustable fins.
• MA: A-type covering cabinet (use tray accessory BC 4 for FCX AS).
• MU: U-type covering cabinet (use the BC 5-6 tray accessory if horizontal, or BC 4 if vertical).
• PCR: Galvanised plate protection for the controls and the electrical element.
• PA: Plenum suction assembly in galvanised sheet metal, complete with suction couplings for circular-section ducts.
• PA-F: Plenum suction assembly that allows intake and delivery on the same side; suitable for all installations where the machine needs to be positioned outside the air-conditioned rooms in order to minimise noise levels and facilitate maintenance operations.
• PM: Delivery plenum in galvanised sheet metal, externally insulated, complete with plastic delivery couplings for circular section ducts.
• RD: Straight delivery coupling for canalisation.
• RDA: Straight suction coupling for canalisation.
• RP: 90° delivery coupling for canalisation.
• RPA: 90° suction coupling for canalisation.
• RX: Armoured electric coil with safety thermostat. (Requires a thermostat with heater management). Not available for 4-row versions or those with Plasmacluster.
• SE: Manually operated fresh air intake louver.
• SIT 3 - 5: Thermostat Interface Cards. They allow the creation of a network of fan coils
(max. 10) commanded by a central control panel (selector or thermostat).
SIT3: commands the 3 fan speeds and must be installed on each fan coil of the network; receives the commands from the selector or the SIT5 card.
SIT5: commands the 3 fan speeds and up to 2 valves (four pipes systems); sends the commands of the thermostat to the fan coils network.
• SW: water temperature probe that gives the automatic season change feature to electronic thermostats supplied with water-side change over.
• SWA: External probe accessory SWA (length L = 6m). It detects the temperature of air or water depending on its location in the plant
• VCF: the kit contains a motorised 3-way valve with insulating shell, plus coupling and pipes in insulated copper. For 4-row, 3-row and
1-row coils (BV). Versions with 230V and
24V~50Hz power supply
• VCFD: Kit consisting of powered 2-way valve, copper couplings and pipes. For 4-row, 3-row and 1-row coils (BV). Versions with 230V and
24V~50Hz power supply.
• VCF_X4: The valve kits are designed for fan coil units with single coil, installed in a 4 pipe system with the "Cooling" and "Heating" circuits totally separated. The kit consists of 2 valves of 3-way 4 port connection complete with electro-thermal actuators, insulating shells for the valves and associated hydraulic piping. VCF1X4L Valve kit for left hand connection fan coil units. VCF1X4R Valve kit for right hand connection fan coil units. Power supply: 230V ~ 50Hz.
• ZX: Feet for recessed installation.
• Control panels and VMF System: the characteristics are described on the appropriate card.
30
Accessories
FMT10 • FMT21
KTLP
PX • PX2 • PX2C6
PXAE
PXAR
TF1
TPF
WMT05 • WMT06 • WMT10
VMF-E4 • VMF-E4D
VMF-E0 • VMF-E1
AMP
AMP20
BC
BV
CHF
142
162
17
22
32
42
62
6
8
4
5
9
117
122
132
DSC4
GA
GAF
GM
MA
MU
PA
PA
PCR
PM
RD
RDA
RP
RPA
RX
42
62
17
22
62
17
22
32
32
42
52
62
17
22
32
42
22
32
42
62
32
42
62
17
42
62
17
22
2
17
22
32
32 F
42 F
62 F
1
62
17
22
32
42
62
17 F
22 F
17
22
32
42
22
32
42
62
32
42
62
17
42
62
17
22
62
17
22
32
17
22
32
42
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(2)
(3)
•
•
•
•
•
•
•
17
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
24
•
•
•
•
•
•
•
•
•
•
•
•
•
•
22
•
•
•
•
•
•
•
•
•
•
•
•
•
•
34
•
•
•
•
•
•
•
•
•
•
•
•
•
•
32
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
36
•
FCX Fan Coil
42
•
44
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• • •
•
•
•
•
•
50
•
•
•
•
•
•
•
•
•
•
•
•
•
•
56
•
•
•
•
•
•
•
•
•
•
•
•
•
•
54
•
•
•
•
•
•
•
•
•
•
• • •
•
• •
• • •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• • • • •
•
• •
• • •
• • • • •
•
• •
• • •
• • • • •
•
• •
• • •
• • • • •
•
• •
• • •
• • • • •
•
• •
• • •
• • • • •
•
• •
• • •
• • • • •
•
•
•
•
•
•
•
•
•
•
• •
• • •
• • • • •
•
• •
• • •
• • • • •
•
• •
• • •
• • • • •
•
• •
• • •
• • • • •
•
• •
• • •
• • • • •
•
•
• •
•
• •
•
•
•
•
•
•
•
•
•
•
•
•
•
64
•
•
•
•
•
•
•
•
•
•
•
•
•
62
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
82
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
84 102 Versions
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
P-PE-PO-PV
P-PE-PO-PV
P-PE-PO-PV
P-PE-PO-PV-PPC
P-PE-PO-PV
P-PE-PO-PV
P-PE-PO-PV
P-PE-PO-PV
• •
P-PE-PO-PV
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PPC
P-PE-PO-PPC
FCX P-PV+ MA
FCX P + MU
FCX P + MU
P-PE-PO-PPC
P-PE-PO-PPC
P-PE-PV
P-PE-PO-PV
P-PE-PO-PV
P-PE-PO-PV
P-PE-PO-PV
P-PV
P-PV
P-PV
P-PV
P-PV
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PPC
P-PE-PV
P-PE-PO-PV
P-PE-PO-PV
P-PE-PO-PV
P-PE-PO-PV
P-PE-PO-PV
31
Accessories
SE
SIT
SW3
SWA
VCF
VCFD
ZX
15X
20X
30X
40X
80X
3
5
1X4L - 1X4R
2X4L - 2X4R
3X4L - 3X4R
41 - 4124
42 - 4224
43 - 4324
44 - 4424
45 - 4524
7
8
1 - 124
2 - 224
3 - 324
4 - 424
(4)
(4)
(4)
(4)
(4)
(5)
(5)
(5)
(5)(6)
(5)
(5)
(5)
(5)
(5)(7)
17
•
•
•
•
•
•
•
•
•
•
•
22
•
•
•
•
•
•
•
•
•
•
•
24
•
•
•
•
•
•
•
•
•
32
•
•
•
•
•
•
•
•
•
•
•
34
•
•
•
•
•
•
•
•
•
36
•
•
•
•
•
•
•
•
•
•
•
FCX Fan Coil
(1) the characteristics are described on the appropriate card.
(2) Accessories and BC4 VCF can not be mounted at the same time
(3) DSC4 is incompatible with the accessory AMP and BC Auxiliary condensate drip tray
42
•
•
•
•
•
•
•
•
•
•
•
44
•
•
•
•
•
•
•
•
•
50
•
•
•
•
•
•
•
•
•
•
•
54
•
•
•
•
•
•
•
•
•
56
•
•
•
•
•
•
•
•
•
•
•
62
•
•
•
•
•
•
•
•
•
•
•
64
•
•
•
•
•
•
•
•
•
(4) The accessory SE require pairing with ZX
(5) 24 Volt
(6)
Only for the BV1-row coil accessory
82
•
•
•
•
•
•
•
•
•
•
•
Technical data
•
•
•
•
•
84 102 Versions
P-PE-PV
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
•
•
•
•
•
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
P-PE-PO-PV
P-PE-PO-PV-PPC
•
•
•
•
•
•
•
•
•
•
P-PO-PV
P-PO-PV
P-PO-PV
P-PO-PV
P-PO-PV
P-PO-PV-PPC
P-PO-PV-PPC
P-PO-PV-PPC
P-PO-PV
P-PO-PV
P-PO-PV-PPC
P-PO-PV-PPC
P-PO-PV-PPC
P-PO-PV
P-PE-PO-PV-PPC
P-PE-PO-PV-PPC
Mod. FCX_P / FCX_PO Vel.
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
Heating capacity (70°C)
(1) W
(1) W
H
M
17 22 24 32 34 36 42 44 50 54 56 62 64 82 84 102
2296 2960 3912 5354 5964 6413 6618 8600 8191 10100 9648 12919 14300 15140 17100 17019
2033 2531 3103 4065 4801 4983 5521 6930 7529 8759 8434 10942 11501 13349 14421 15242
Water flow rate
Pressure drop
(1)
(1)
(1)
(1) W
(1) l/h
(1)
(1) l/h l/h kPa kPa kPa
L
H
M
L
H
M
L
1686 1906 2097 3165 3728 4188 4062 5200 5021 6241 6056 8327 8499 10771 11198 12558
201
178
148
3
2
1
260
222
167
6
4
3
343
272
184
4
3
1
470
357
278
20
12
8
523
421
327
11
7
5
563
437
367
13
10
8
581
484
356
15
11
6
754
608
456
22
15
9
718
660
440
15
13
6
886
768
547
23
18
9
846
740
531
42
33
19
1133
960
730
17
12
7
1254
1009
745
23
16
9
1328
1171
945
21
16
11
1500
1295
982
32
23
15
1493
1337
1101
43
34
24
Heating capacity (50°C)
(2) W
(2) W
(2) W
(2) l/h
H
M
L
H
1360
1200
990
172
1770
1510
1130
258
2320
1840
1250
298
3160
2400
2060
413
3550
2860
2220
482
3800
2950
2480
482
3960
3300
2430
585
4950
4140
3170
765
4870
4480
3000
721
6100
5220
3700
855
5380
4840
3680
791
7500
6430
4880
836
8400
6800
5040
1092
7960 10200 10000
6860
5200
1189
8600
6700
1479
9000
7440
1311
Water flow rate (2)
(2)
(2)
(2) l/h l/h kPa kPa
M
L
H
M
144
112
2
2
210
144
6
5
236
174
3
2
316
267
16
10
392
303
9
7
370
311
9
7
478
397
15
13
617
463
23
15
604
432
15
11
743
533
22
17
662
475
22
20
752
554
9
7
896
674
18
13
860 1259 1183
738 992 979
21
12
31
23
33
27
Pressure drop
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
Heating capacity (70°C)
Water flow rate
Pressure drop
(2)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3) kPa
W
W
W l/h l/h l/h kPa kPa
L
H
M
L
H
M
L
H
M
1
1400
1200
990
123
105
87
3
2
2
1770
1510
1130
155
132
99
6
5
1
-
-
-
-
-
-
-
-
7
2850
2450
2030
250
215
178
16
12
4
-
-
-
-
-
-
-
-
6
-
-
-
-
-
-
-
-
8
3460
3410
2660
303
299
233
21
20
9
-
-
-
-
-
-
-
-
6
4380
3940
3220
384
346
282
35
30
9
-
-
-
-
-
-
-
-
15
-
-
-
-
-
-
-
-
4
5490
4700
3870
482
412
339
16
12
8
-
-
-
-
-
-
-
-
9
6410
6300
5300
562
553
465
15
14
15
-
-
-
-
-
-
-
-
19
6810
6230
5430
6809
6232
5428
19
16
Total cooling capacity
(3)
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
(4) W H 1000 1500 1730 2400 2800 2800 3400 4450 4190 4970 4600 4860 6350 6910 8600 7620
(4) kPa
W
(4) W
L
M
L
2
840
650
3
1220
840
-
1370
1010
8
1840
1550
-
2280
1760
-
2150
1810
14
2780
2310
-
3590
2690
21
3510
2510
-
4320
3100
-
3850
2760
10
4370
3220
-
5210
3920
11
5000
4290
-
7320
5770
13
6880
5690
Sensible cooling capacity
Water flow rate
Pressure drop
Air flow rate
Fans
Absorbed power
(4)
(4)
(4)
(4)
(4)
(4) W
(4) W
(4) W
(4) l/h l/h l/h kPa kPa kPa m
3
/h m
3
/h m
3
/h type n°
W
W
W
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
830 1240 1380 1900 2130 2200 2760 3300 3000 3540 3500 3980 5030 5680 5780 5530
690 1000 1090 1570 1720 1820 2110 2640 2540 3060 3070 3300 4100 3780 4870 5350
510 670 760 1110 1250 1280 1630 1960 1790 2170 2120 2440 3060 2970 2800 4420
172 258 298 413 482 482 585 765 721 855 791 836 1092 1189 1479 1311
144
112
2,6
2
1,4
200
160
110
1
35
29
19
210
144
5,8
5
2,5
290
220
140
1
25
22
19
236
174
3
2
1
290
220
140
1
33
29
25
316
267
28
17
13
450
350
260
2
44
33
25
392
303
13,8
10
6
450
350
260
2
44
34
28
370
311
28
17
12,7
450
350
260
2
44
33
25
478
397
14,3 40,2 19,3 25,9
10
7
600
460
330
2
57
43
30
617
463
27
16,3
600
460
330
2
57
43
30
604
432
14
7,6
720
600
400 centrifugal
2
67
46
34
743
533
21
11,7 15,1
720
600
400
2
76
52
38
662
475
38
28
720
600
400
2
76
52
38
752
554
17,3
14
8,3
920
720
520
3
82
61
40
896
674
13
9
5,5
860 1259 1183
738
22
12
9,3
992
29,5
22
14,7
979
37,3
31
22
920 1140 1140 1300
720 930 930 1.120
520 700 700 900
3
91
60
38
3
106
80
59
3
106
80
59
3
131
100
80
32
Mod. FCX_P / FCX_PO
Max input current
Sound power level (P)
Sound pressure level (P)
Sound power level (PO)
Sound pressure level (PO)
Water content
Coil connections
Speed connected
(6)
(6)
(5)
(5)
(5)
(6)
(P) (A)
(PO) (A)
(5) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)
(6)
P
P
P l dB(A)
ø (4R)
ø (3R)
ø (1R)
Vel.
M
L
H
H
M
L
H
H
H
M
L
17 22 24 32 34 36 42 44 50 54 56
0,16 0,12 0,25 0,21 0,45 0,21 0,28 0,51 0,35 0,36 0,35
-
45
38
31
37
62
0,4
64 82 84 102
0,48 0,49 0,62 0,58
0,25 0,25 0,45 0,45 0,45 0,51 0,51 0,36 0,36 0,36 0,48 0,48 0,62 0,62
50
43
31
42
51
46
35
43
48
41
34
40
48
41
36
40
48
41
34
40
51
44
37
43
55
50
41
47
56
51
42
48
56
53
44
48
56
51
42
48
57
51
42
49
57
51
44
49
61
56
51
53
61
57
51
53
-
66
61
56
58
30
23
-
35
23
58
38
27
58
33
26
53
33
28
53
33
26
53
36
29
59
42
33
59
43
34
59
45
36
59
43
34
59
43
34
62
43
36
62
48
43
64
49
43
64
53
48
-
50
0,58 0,79
-
1/2" 1/2"
1/2" 1/2"
V3
V2
V1
V3
V2
V1
50
1
3/4"
-
-
V3
V2
V1
44
-
1/2"
1/2"
V3
V2
V1
44
1,11 1,5
3/4"
-
-
V3
V2
V1
44 50 50 51
1,5 1,48 1,9 1,48
-
3/4"
1/2"
V3
V2
V1
-
3/4"
1/2"
V3
V2
V1
3/4"
-
-
V3
V2
V1
-
3/4"
1/2"
V3
V2
V1
230V/1/50Hz
51
1,9
3/4"
-
-
V3
V2
V1
51
-
3/4"
1/2"
V3
V2
V1
54
1,9 2,52
-
3/4"
1/2"
V3
V2
V1
54 56
3,4 2,52
3/4"
-
-
V3
V2
V1
-
3/4"
1/2"
V3
V2
V1
56
3,4 2,52
3/4"
-
-
V3
V2
V1
-
-
3/4"
1/2"
V3
V2
V1
Power supply
H max. speed; M med. speed; L min. speed
Heating mode
2 pipes system configuration
(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode
4 pipes system configuration (with additional heat exchanger) (EUROVENT)
(3)Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C
Cooling mode (EUROVENT)
(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C
FCX22÷50
Speed
V1 V2 V3 V4 V5 V6
V1 V2 V3 V4 V5 V6 V7
L7 L6 L5 L4 L3 L2 L1
FCX62÷82
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(6) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: The speed of associates may differ from the standard factory configuration, for more information refer to the program selection and the technical documentation available on the website www.aermec.com
Dimensions (mm)
FCX_P (standard coil/augmented coil)
C
D
A
B
FCX_P 20-30-36-40-50-56
FCX_P 24-34-44-54
B
9x20
(standard coil)
(augmented coil)
Mod FCX_P
Height
Width
Depth
Weight
* Overall dimensions
A
B*
D
C kg
17
453
452
412
216
11
22 /24 32/34/36 42/44 50/54/56 62/64 82/84
453
562
522
453
793
753
453
1013
973
453
1013
973
558
1147
1122
558
1147
1122
216
13
216
18
216
22
216
22
216
33
216
33
F G H
I
L
102
558
1147
1122
216
33
M
E
FCX_P 80
FCX_P 84
9x20
B
(standard coil)
(augmented coil)
F G H
E
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.
I
L
M
F
G
I
H
E
L
M
17
330
41
101
74
49
144
260
22/24 32/34/36 42/44 50/54/56 62/64 82/84
440
41
101
74
49
144
260
671
41
101
74
49
144
260
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577 www.aermec.com
891
41
101
74
49
144
260
891
41
101
74
49
144
260
1102
41
107
68
32
253
273
1102
41
107
68
32
253
273
102
1102
41
107
68
32
253
273
33
FCXI P
Fan coils with Brushless Inverter motor (EC)
In-duct installation
Aermec is participating in the EUROVENT Program
: FCH/FCPH
The related products can be found at the website www.eurovent-certification.com
• ELECTRIC SAVING EQUAL TO 50% COMPARED TO A
FAN COIL WITH 3-SPEED MOTOR
• FULLY SILENT FUNCTIONING
• FULL COMFORT: REDUCED TEMPERATURE AND
RELATIVE HUMIDITY OSCILLATIONS
Features
Recessed fan coils with inverter technology, for heating, cooling and dehumidifying, specific to work in sensible environment.
Equipped with inverter Brushless motor for an high effciency and a continuos air flow rate modulation in order to increased comfort and guarantee electric saving. The inverter motor allows a better air temperature regulation on based on the real indoor envirorement requirements without temperature swinging.
The FCXI P are the ideal solution for 2/4-pipe systems and for tertiary and commercial installations.
Versions:
FCXI P: wall/ceiling mounted without cabinet
FCXI PBV: wall/ceiling mounted without cabinet with double circuit coil for 4-pipe system with standard connections (left)
FCXI PBVD: wall/ceiling mounted without cabinet with double circuit coil for 4-pipe system with right connections
The hydraulic connections of the BV and BVD versions, up to size 56, are not reversible during installation. Specify the connection side when
placing the order.
• Brushless motor with 0-100% speed continuous variation to guarantee best performance at very low sound level
• Centrifugal fan designed to guarantee continuous modulation of the air flow rate and to increase comfort and electric saving.
• Unit with standard coil (20 ÷80)
• Unit with larger coil (24
÷84)
• Low pressure drop
• Air filter with easy extraction and cleaning
• Removable augers for easy and effective cleaning
• Reversibility of the hydraulic connections in the installation phase
A specific wall-control range is available for the
FCXI P. Choose between these panels for simple and complete regulation. Refer to the specific sheet for further details.
Accessories
• WMT21: Electronic thermostat with LCD display (wall installation).
• SWAI: Water temperature probe for WMT21 electronic thermostat.
• VMF System: Find the features in the specific sheets.
• AMP: Kit for wall/ceiling mounted installation.
• BC: Auxiliary condensate drip tray.
• BV: Hot water coil with one row. It is not available for versions with 4 rows or with Plasmacluster.
Specify the connection side in case of in-site
assembly.
• PMZ: Plenum with motorised dampers (refer to the specific sheet for further details).
• CHF: The VentilCassaforma is a galvanised sheet steel template, for P versions, which allows you to obtain a space for housing the fan coil, directly in the wall.
• DSC4: Device for draining condensate.
• GA: Intake grid with fixed louvers.
• GAF: Intake grid with fixed louvers with filter.
• GM: Flow grid with adjustable louvers.
• MA: Protective cabinet, type A (use BC 4 tray accessory).
• MU: Protective cabinet, type U (use BC 5-6 tray accessory if horizontal or use BC 4 if vertical).
• PA: Galvanised sheet steel intake plenum equipped with intake fittings for circular section ducts.
• PA-F: Intake plenum, which allows recovery and flow on the same side. It is suitable for all those installations outside air-conditioned rooms, in order to minimise noise and facilitate maintenance operations.
• PM: Galvanised sheet steel flow plenum, externally insulated, equipped with plastic flow fittings for ducts and circular sections.
• RD: Straight flow fitting for ducting.
• RDA: Straight intake fitting for ducting.
• RP: 90° flow fitting for ducting.
• RPA: 90° intake fitting for ducting.
• SE: External air damper with manual control.
• VCF: Kit made up of 3-way motorised valves with insulating shell, insulated copper fittings and pipes. For 4, 3, and 1-row coils (BV) Versions with
230V and 24V~50Hz power supply.
• VCFD: Kit composed of 2-way motorised valve and copper pipes and connections. For 4, 3, and
1-row coils (BV) Versions with 230V and
24V~50Hz power supply.
• Control panels and VMF System:
Find the features in the specific sheets.
34
Accessories
FCXI_P
WMT21
SWAI
AMP
AMP20
BC 6
8
4
5
9
122
132
142
162
22
32
42
62
(3)
(3)
(3)
(3)(4)
(3)(4)
(3)(4)
(3)(4)(5)
(3)(4)
(3)
(3)
(3)
(3)(5)
20
•
•
•
•
•
•
•
24
•
•
•
•
•
•
•
30
•
•
•
•
•
•
•
34
•
•
•
•
•
•
•
36
•
•
•
•
•
•
•
40
•
•
•
•
•
•
•
44
•
•
•
•
•
•
•
50
•
•
•
•
•
•
•
54
•
•
•
•
•
•
•
56
•
•
•
•
•
•
•
80
•
•
•
•
•
•
84
•
•
•
•
•
•
BV
CHF
DSC4
GA
GAF
GM
MA
MU
PA
PA
PM
RD
RDA
RP
RPA
SE
VCF
VCFD
ZX
20X
30X
40X
80X
1X4L - 1X4R
2X4L - 2X4R
3X4L - 3X4R
41 - 4124
7
8
42 - 4224
43 - 4324
44 - 4424
45 - 4524
1 - 124
2 - 224
3 - 324
4 - 424
22
32
42
62
22
32
42
62
22
32
42
62
22
32
42
62
22
32
42
62
22F
32F
42F
62F
22
32
42
62
22
32
42
62
22
32
42
62
22
32
42
62
22
32
42
62
22
32
42
62
(1)(2)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
(1) The DSC4 accessory is not compatible with the BC4_5_6_8_9 trays and AMP installation brackets. It is compatible only with AMP20.
(2) DSC4 and the VMF-system accessories cannot be installed simultaneously on the same fan coil
(3) The VCF / VCFD valves and the BC4 tray cannot be installed simultaneously on the same fan coil
(4) VCF4124-4224-4324-4424-4524 / VCFD124-224-324-424 are 24V
(5) For BV coil with 1 row or for PBV/PBVD versions.
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
(P+MA)
(P+MU)
(P+MU)
P
35
Technical data (Eurovent FCH)
Mod. FCXI_P without static pressure Speed
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1) W H
Thermal power (70°C) (1)
(1)
(1)
W
W l/h
M
L
H
Water flow rate pressure drops
(1)
(1)
(1)
(1) l/h l/h kPa kPa
M
L
H
M
20
2960
2531
1906
260
222
167
24
3912
3103
2097
343
272
184
30
5354
4065
3165
470
357
278
Thermal power (50°C)
(1)
(2)
(2)
(2)
(2) kPa
W
W
W l/h
L
H
M
L
H
6
4
3
1,770
1,510
1,130
258
4
3
1
2,320
1,840
1,250
298
20
12
8
3,160
2,400
2,060
413
Water flow rate (2)
(2)
(2)
(2) l/h l/h kPa kPa
M
L
H
M
210
144
6
5
236
174
3
2
316
267
16
10 pressure drops
(2) kPa L 2 1 7
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
Thermal power (70°C)
(3)
(3)
W
W
H
M
1,770
1,510
-
-
2,850
2,450
Water flow rate
Pressure drops
(3)
(3)
(3)
(3)
(3)
(3)
(3)
W l/h l/h l/h kPa kPa kPa
M
L
L
H
L
H
M
1,130
155
132
5
3
99
6
-
-
-
-
-
-
-
2,030
250
215
178
16
12
8
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
(4) W H 1500
Total cooling capacity (4)
(4)
W
W
M
L
1,220
840
Sensitive cooling capacity
(4)
(4)
(4)
(4)
W
W
W l/h
H
M
L
H
1240
1,000
670
258
Water flow rate
Water pressure drops
Air flow rate
(4)
(4)
(4)
(4)
(4) l/h l/h kPa kPa kPa m3/h m3/h
M
L
H
M
L
H
M
L
Centrifugal
Input power
Maximum input current
Sound power level
Sound pressure level
Water content
Coil connections
Work percentage compared to the configuration signal
(5)
(5)
(5)
(6)
(6)
(6) m3/h type n°
W
W
W
(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)
%
%
% l
ø (4R)
ø (3R)
ø (1R)
H
M
L
H
M
L
H
M
L
H
M
L
8
5
1
12
0.12
50
43
210
144
5.8
5
2.5
290
220
140
0.79
-
1/2"
1/2"
90
84
44
31
42
35
23
Electric power supply
1730
1,370
1010
1380
1,090
760
298
236
174
3
2
1
290
220
140
1
12
8
5
0.12
51
46
35
43
38
27
1
3/4"
-
-
90
84
44
2400
1,840
1550
1900
1,570
1110
413
316
267
28
17
13
450
350
260
1.11
-
1/2"
1/2"
90
84
48
34
40
33
26
7
4
2
13
0.21
48
41
34
5964
4801
3728
523
421
327
11
7
5
3,550
2,860
2,220
482
392
303
9
7
4
-
-
-
-
-
-
-
-
-
2800
2,280
1760
2130
1,720
1250
482
392
303
13.8
10
6
450
350
260
2
13
7
4
0.21
48
41
36
40
33
28
1.5
3/4"
-
-
90
84
48
36
6413
4983
4188
563
437
367
13
10
8
3,800
2,950
2,480
482
370
311
9
7
6
-
-
-
-
-
-
-
-
-
2800
2,150
1810
2200
1,820
1280
482
370
311
28
17
12.7
450
350
260
2
13
7
4
0.21
48
41
34
40
33
26
1.5
-
3/4"
1/2"
90
84
48
40
6618
5521
4062
581
484
356
15
11
6
3,960
3,300
2,430
585
478
397
15
13
8
3,460
3,410
2,660
303
299
233
21
20
14
3400
2,780
2310
2760
2,110
1630
585
478
397
14.3
10
7
600
460
330 centrifugal
2
17
9
6
0.28
51
44
1.48
-
3/4"
1/2"
37
43
36
29
90
82
52
230V/1/50Hz
44
8600
6930
5200
754
608
456
22
15
9
4,950
4,140
3,170
765
617
463
23
15
9
-
-
-
-
-
-
-
-
-
4450
3,590
2690
3300
2,640
1960
765
617
463
40.2
27
16.3
600
460
330
2
17
9
6
0.28
55
50
41
47
42
33
1.9
3/4"
-
-
90
82
52
50
8191
7529
5021
718
660
440
15
13
6
4,870
4,480
3,000
721
604
432
15
11
6
4,380
3,940
3,220
384
346
282
35
30
21
4190
3,510
2510
3000
2,540
1790
721
604
432
19.3
14
7.6
720
600
400
2
37
20
8
0.35
56
51
42
48
43
34
1.48
-
3/4"
1/2"
90
86
60
54
10100
8759
6241
886
768
547
23
18
9
6,100
5,220
3,700
855
743
533
22
17
9
-
-
-
-
-
-
-
-
-
4970
4,320
3100
3540
3,060
2170
855
743
533
25.9
21
11.7
720
600
400
2
37
20
8
0.35
56
53
44
48
45
36
1.9
3/4"
-
-
90
86
60
56
H maximum speed; M medium speed; L minimum speed
Heating
2-pipe system configuration
(1) Ambient air temperature 20°C d.b.; Inlet water temperature 70°C; DT water 10°C
2-pipe system configuration (EUROVENT)
(2) Ambient air temperature 20°C d.b.; Inlet water temperature 50°C; Water flow rate the same as in Cooling mode
4-pipe system configuration with additional heat exchanger
(3) Ambient air temperature 20°C d.b.; Inlet water temperature 70°C; DT water 10°C
Cooling (EUROVENT)
(4) Ambient air temperature 27°C d.b./19°C w.b.; Inlet water temperature 7°C; DT water 5°C
(5) Sound power based on the measurements carried out in accordance with Eurovent 8/2 standard
(6) Sound pressure level (A weighted) measured in environment with volume V=85m3 , reverberation time t=0.5s directivity factor Q=2; distance r=2.5m
Note: For further information, refer to the selection program or to the technical documentation on www.aermec.com
1.9
-
3/4"
1/2"
90
86
60
42
48
43
34
2
37
20
8
0.35
56
51
4600
3,850
2760
3500
3,070
2120
791
662
475
38
28
15.1
720
600
400
42
33
19
5,380
4,840
3,680
791
662
475
22
20
15
9648
8434
6056
846
740
531
-
-
-
-
-
-
-
-
-
80
15140
13349
10771
1328
1171
945
21
16
11
7,960
6,860
5,200
1189
860
738
21
12
9
6,410
6,300
5,300
562
553
465
15
14
11
6910
5,000
4290
5680
3,780
2970
1189
860
738
22
12
9.3
1140
930
700
2.52
-
3/4"
1/2"
90
84
45
51
53
48
43
3
80
40
30
0.49
61
56
36
84
17100
14421
11198
1500
1295
982
32
23
15
10,200
8,600
6,700
1479
1259
992
31
23
15
-
-
-
-
-
-
-
-
-
3.4
3/4"
-
-
90
84
45
51
53
49
43
3
80
40
30
0.49
61
57
8600
7,320
5770
5780
4,870
2800
1479
1259
992
29.5
22
14.7
1140
930
700
Technical data (Eurovent FCPH)
Mod. FCXI_P with static pressure Speed
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1) W H
Thermal power (70°C) (1)
(1)
(1)
W
W l/h
M
L
H
Water flow rate pressure drops
(1)
(1)
(1)
(1) l/h l/h kPa kPa
M
L
H
M
20
2772
2665
1754
243
234
154
24
3611
3426
1968
317
301
173
30
4730
4420
3154
415
388
277
Thermal power (50°C)
(1)
(2)
(2)
(2)
(2) kPa
W
W
W l/h
L
H
M
L
H
5
5
2
1640
1600
1000
232
4
3
1
2136
2026
1171
267
14
12
7
2700
2560
1810
365
Water flow rate (2)
(2)
(2)
(2) l/h l/h kPa kPa
M
L
H
M
220
131
5
5
253
162
3
2
342
222
6
6 pressure drops
(2) kPa L 2 1 5
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
Thermal power (70°C)
Water flow rate
Pressure drops
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
W
W
W l/h l/h l/h kPa kPa kPa
H
M
L
H
M
L
H
M
L
1670
1620
1120
144
139
96
6
6
3
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
Total cooling capacity
Sensitive cooling capacity
Water flow rate
Water pressure drops
Air flow rate
Centrifugal
Useful static pressure
Input power
Maximum input current
Sound power level
(Inlet+radiator)
Sound power level
(outlet)
Water content
Coil connections
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(5)
(5)
(5)
(6)
(6)
(6)
W
W
W
W
W
W l/h l/h l/h kPa kPa kPa m3/h m3/h m3/h type dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l
ø (4R)
ø (3R)
ø (1R)
W
W
W
(A) n°
Pa
Pa
Pa
H
M
L
M
L
L
H
M
L
H
M
H
M
L
H
H
M
L
H
M
L
H
M
L
H
M
L
58
57
37
54
53
33
0,79
-
1/2"
1/2"
1
57
50
14
30
25
8
131
5
4
2
257
240
123
1350
1280
760
1130
1070
590
232
220
-
-
-
-
-
-
-
-
-
1555
1469
940
1243
1173
690
267
253
162
3
2
1
257
240
123
1
57
50
14
30
25
8
58
57
37
54
53
33
1
3/4"
-
-
2750
2640
1940
237
227
167
26
24
8
2
59
50
16
40
31
10
46
32
1,11
-
52
50
36
48
1/2"
1/2"
222
26
23
11
424
390
225
2120
1990
1290
1640
1540
980
365
342
Work percentage compared to the configuration signal
Electric power supply
%
%
%
H
M
L
90
84
44
90
84
44
90
84
48
H maximum speed; M medium speed; L minimum speed
Heating
2-pipe system configuration
(1) Ambient air temperature 20°C d.b.; Inlet water temperature 70°C; DT water 10°C
2-pipe system configuration (EUROVENT)
(2) Ambient air temperature 20°C d.b.; Inlet water temperature 50°C; Water flow rate the same as in Cooling mode
4-pipe system with additional heat exchanger (EUROVENT)
(3) Ambient air temperature 20°C d.b.; Inlet water temperature 70°C; DT water 10°C
Cooling (EUROVENT)
(4) Ambient air temperature 27°C d.b./19°C w.b.; Inlet water temperature
7°C; DT water 5°C
(5) Sound power based on the measurements carried out in accordance with
Eurovent 8/2 standard
(6) Sound pressure level (A weighted) measured in environment with volume
V=85m3 , reverberation time t=0.5s directivity factor Q=2; distance r=2.5m
34
-
-
-
-
-
-
-
-
-
2
59
50
16
40
31
10
46
32
1,5
3/4"
52
50
36
48
-
-
90
84
48
266
13
11
5
424
390
225
2671
2495
1544
2035
1898
1042
459
429
8
7
3
3331
3129
2039
459
429
266
7
6
3
5600
5262
3442
491
462
302
Dimension and weight data
A
36
4730
4420
3154
415
388
277
14
12
7
2801
2620
1858
364
343
221
11
10
4
2750
2640
1940
241
232
170
26
24
14
2117
1996
1284
1665
1551
968
364
343
221
26
24
11
424
390
225
2
59
50
16
40
31
10
52
50
36
48
46
32
1,5
-
3/4"
1/2"
90
84
48
3020
2820
1920
2310
2150
1450
519
485
330
12
10
5
515
470
300 centrifugal
2
60
50
20
48
38
16
55
53
43
51
49
39
1,48
-
3/4"
1/2"
90
82
52
230V/1/50Hz
D
40
3210
3070
2430
276
264
209
18
17
11
13
12
7
4050
3850
2800
519
485
330
10
9
4
6852
6499
4764
601
570
418
Mod FCXI_P
Height
Width
Depth
Weight
A mm
B* mm
D mm
C mm kg
44
18
15
8
4550
4219
2856
678
629
424
18
16
8
7610
7056
4777
668
619
419
49
39
1,9
3/4"
-
-
55
53
43
51
90
82
52
424
32
28
14
515
470
300
3942
3656
2468
2908
2690
1794
678
629
2
60
50
20
48
38
16
-
-
-
-
-
-
-
-
-
C
50
51
41
1,48
-
57
55
45
53
3/4"
1/2"
90
86
60
464
16
15
9
630
600
410
3800
3670
2700
2880
2770
2030
654
631
2
55
50
23
60
50
18
4090
3990
3280
352
343
282
31
31
22
54
12
12
7
4657
4488
3297
657
635
465
12
11
6
7815
7531
5534
686
661
485
743
544
18
17
10
19
18
10
5429
5222
3802
772
9106
8759
6375
799
768
559
12
12
7
4650
4480
3350
654
631
464
12
10
10
7815
7531
5534
686
661
485
51
41
1,9
3/4"
57
55
45
53
-
-
90
86
60
544
22
20
12
630
600
410
4488
4320
3165
3184
3061
2217
772
743
2
55
50
23
60
50
18
-
-
-
-
-
-
-
-
-
56
51
41
1,9
-
57
55
45
53
3/4"
1/2"
90
86
60
465
16
15
9
630
600
410
3821
3692
2704
2837
2756
2061
657
635
2
55
50
23
60
50
18
4090
3990
3280
352
343
282
31
31
22
80
58
55
38
54
51
34
2,52
-
3/4"
1/2"
90
84
45
487
13
12
4
799
730
405
5240
4860
2830
3930
3640
2090
901
836
3
60
50
15
78
61
23
6100
5700
3530
525
490
304
12
10
5
84
B
C
D
20 /24 30/34 /36 40/44 50/54/ 56 80/84
453 453 453 453 558
562
522
216
13
A
793
753
216
18
1013
973
216
22
B
1013
973
216
22
1147
1122
216
33
51
34
3,4
3/4"
-
-
58
55
38
54
90
84
45
611
18
15
6
799
730
405
6456
5981
3552
4270
3944
2311
1110
1029
3
60
50
15
78
61
23
-
-
-
-
-
-
-
-
-
11960 12623
11144 11635
6521
1049
978
572
6618
1107
1021
581
14
12
5
7000
6500
3800
901
836
487
11
9
4
18
16
6
7542
6954
3965
1.110
1.029
611
18
16
6
Aermec reserves the right to make all the modifications deemed necessary for improving the product, including technical data.
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 039 0442633111 - Telefax +39 044293577 www.aermec.com
37
Omnia UL
Fan coils
Ceiling installations
Aermec
participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com
Features
• UL (Universal Line) fan coils for both horizontal and vertical installation
• Versions:
UL-P Without cabinet for ceiling installation
• Fan cleaning: Omnia fan coils allow fan blades to be easily cleaned. It is now possible to remove the fan volute (it contains the fan blades) and clean it periodically.
• Condensate drip tray cleaning: Thanks to a new drip tray fitting, it is now easier to clean it with Omnia fan coils. This important solution avoids, in the long run, bacteria, germs and mould to grow up, in the drip tray because of the air humidity.
• Precharged electrostatic filter: Omnia fan coils have, as standard, precharged electrostatic filters. These filters, thanks to their special execution, attracts and retains all suspended dust particles, thus garanteeing pure breathable air to the whole family.
• PLASMACLUSTER ionising filter:
Plasmacluster is capable of reducing the level of pollutants, by decomposing the molecules that form them. Using a series of electric shocks, "Plasmacluster" causes the water molecules present in the air to separate into positive and negative ions. These ions neutralise the gas pollutant molecules, forming products that are normally present in clean air. The result is in the air: you can finally breath clean, odour-free ionised air.
• Silent operation: Thanks to the use of special centrifugal fans, Omnia fan coils operation is extremely silent and offers the maximum acoustic comfort.
• 3-speed centrifugal fan
• Very quiet operation
• Slim dimensions
• Water connections reversibility during installation
• Low pressure drop across heat exchanger
• Motors with permanently connected condensers
• Easy installation and maintenance
• Air filter easy to remove and to clean
• Full compliance with safety regulations
Accessories
• BC: Auxiliary condensate drip tray.
BC 10 for vertical installation
BC 20 for horizontal installation
• DSC5: Condensate drainage device for use when natural run-off is not possible. DSC5 is not compatible BC10 - BC20 accessories.
• SIT 3-5: Thermostat interface cards. They allow to set up a fancoils network (max. 10) commanded by a centralised panel (switch or thermostat).
SIT3: commands the three speeds of the fan and must be installed on each fancoil of the network; it receives the commands from the switch or from the SIT5 card.
SIT5: commands the 3 fan speeds and up to two valves (four-pipe systems); it sends the thermostat commands to the fancoils network.
• SW: Water probe wich enables automatic season change-over thanks to the specific electronic thermostats.
• SWA: External probe accessory SWA (length L
= 6m). It detects the temperature of the room air if connected to the connector (A) of the
FMT21 panel. The room air temperature probe, incorporated in the panel, is automatically disabled. It detects the temperature of the water in the system for ventilation consent if connected to the connector (W) of the
FMT21 panel. Two SWA probes can be connected simultaneously to the FMT21 panel.
• VCH: Kit comprising motorized 3-way valve, unions and copper pipes.
• VCHD: Kit comprising motorized 2-way valve, unions and copper pipes.
• ZU: Feet for floor-standing solutions.
• Control panels and VMF System: The control panels are described in a separate document.
38
Omnia UL_P
FMT21
PX2 o PX2C6
PXAE
TPF
WMT05
WMT10
VMF-E4 o E4D
VMF-E0 o E1
AMP10
BC10
BC20
DSC5
SIT3
SIT5
SW3
SWA
VCH
VCHD
(1)
(2)
•
•
•
•
•
•
•
•
•
•
•
•
11
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
16
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
26
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
36
•
•
•
•
•
•
(1) PX2C6, PX2 panel in multiple 6-piece pack.
(2) The DSC5 accessory is not compatible BC10 - BC20 accessories.
Technical data
Mod.
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1) W
Heating capacity (70°C)
(1)
(1)
W
W
Water flow rate
Pressure drop
Heating capacity (50°C)
Water flow rate
Pressure drop
(1)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(1)
(1)
(1)
(1)
(1) kPa
W
W
W l/h l/h l/h kPa kPa kPa l/h l/h l/h kPa kPa
COOLING PERFORMANCE
Total cooling capacity
Sensible cooling capacity
Water flow rate
Pressure drop
Air flow rate
Fans
Absorbed power
Max. input current
Sound power level
Sound pressure level
Water content
Coil connections
(5)
(5)
(5)
(4)
(4)
(4)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3) n°
W
W
W
(A) dB(A) dB(A) dB(A) dB(A) dB(A) l dB(A) l/h l/h l/h kPa kPa kPa m
3
/h m
3
/h m
3
/h type
W
W
W
W
W
W
ø
Speed connected
Vel.
M
L
L
H
H
M
M
L
L
H
H
M
L
H
M
H
M
L
M
L
L
H
H
M
L
H
M
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
UL11P
1
1150
870
650
144
117
93
2
1
1
2010
1460
1060
176
128
93
2
1
144
117
93
1,9
1
1
180
120
80
840
680
540
700
530
390
0,09
46
37
31
1
18
12
8
37,5
28,5
22,5
0,4
1/2"
V3
V2
V1
UL16P
1
1700
1250
930
206
153
122
4
2
2
2910
2120
1540
255
186
135
4
2
206
153
122
4,8
3
2
240
160
110
1200
890
710
990
710
540
1
32
25
23
0,15
48
43
34
39,5
34,5
25,5
0,5
1/2"
V3
V2
V1
Centrifugal
UL26P
5
2750
2240
1670
349
289
220
10
7
4
4620
3830
2890
405
336
253
11
8
349
289
220
11
9
5
350
270
190
2030
1680
1280
1640
1330
990
0,18
48
43
35
2
35
27
24
39,5
34,5
26,5
0,8
1/2"
V3
V2
V1
Power supply
230V/1/50Hz
H max. speed; M med. speed; L min. speed
Heating mode
2 pipes system configuration
(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; DT water 10°C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode
Cooling mode (EUROVENT)
(3) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C
(4) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(5) Sound pressure level (A-weighted) measured in the room with volume V=85m3, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com
UL36P
487
394
286
18,9
12
7
460
350
240
2830
2290
1660
2040
1620
1160
2
42
35
30
0,22
50
43
34
39,5
32,5
25,5
1,1
1/2"
V3
V2
V1
3
3540
2860
2080
487
394
286
16
11
6
5940
4870
3530
521
427
310
7,7
5,4
Dimensions (mm)
Mod Omnia
Height
Widht
Depth
Weight
*overall dimensions
UL 11P UL 16P UL 26P UL 36P
A 465 465 465 465
B* 420.5
530.5
761.5
981.5
D 360.5
470.5
701.5
921.5
C kg
171
10.2
171
11.6
171
14.9
171
18.3
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.
A
D
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577 www.aermec.com
B
C
D
A
C
B
Mod Omnia
Height
Widht
Depth
Height with feet
Weight
C
D
A
B kg
UL 11 UL 16 UL 26 UL 36
513
640
513
750
513
980
513
1200
173
93
12,5
173
93
13,5
173
93
16,5
173
93
19,5
39
VED
Fan coil unit
For ducted installations with cooling capacity from 0.99 to 5.82kW
Aermec participates in the EUROVENT
Certification Programme FCP. The products of interest can be found on the site: www.eurovent-certification.com
• HORIZONTAL OR VERTICAL INSTALLATION
• VERSIONS FOR 2/4 PIPE SYSTEMS
• 1 ROW HEATING ONLY COIL (ACCESSORY BV)
• LARGE RANGE OF AVAILABLE STATIC PRESSURE
• ACCESSIBLE FAN ASSEMBLY
• AIR FILTER CLASS G3
• REVERSIBLE COIL
Unit selection
By choosing the appropriate options it is possible to select the model to suit the specific system requirements.
Configuration fields:
1 2 3
❘
Code
❘
4
Size
❘
5
Main Coil
6
❘
0
Example:
1 2 3
❘
VED
❘
4
0
(VED030 = unit Size 0, with 3 Row Main Coil)
5
❘
3
6
0
❘
Characteristics
• Ducted air conditioning terminal unit
• Horizontal and vertical installation
• Internal installation
• Available in 8 sizes
• 3 or 4 row coils for 2-pipe systems
• 3 row main coil and heating only coil accessory for 4-pipe systems
• Reversing of hydraulic connections side on site
• Low pressure drop heat exchanger
• 3-way valve accessory
• 2-way valve accessory for variable flow systems
• 6 and 7 speed fan assembly (3 selectable)
• Large range of available static pressure
• Centrifugal fans in anti-static plastic material.
Their characteristics permit energy savings compared to conventional fans
• Fans with aerofoil profile designed to achieve high airflows and pressures whilst at the same time producing low noise
• Compatible with the VMF system
• Large range of controllers
• Large range of accessories to satisfy all installation requirements
• Compatible with many accessories already available on the FCX range
• Discharge connection supplied loose
• Air filter Class G3, for easy removal and cleaning
• Internal insulation in Class 1 fire retardant material
• Protective rating IP20
• Fan housing in plastic material removable for easy and effective cleaning
• Ease of installation and maintenance
• Full compliance with safety standards.
40
Accessories
DUCTING ACCESSORIES
Plenum in galvanised sheet steel and connections:
• RDA_V: Straight intake connection with rectangular flange.
• RDAC_V: Straight intake connection with circular flanges.
• RPA_V: Intake plenum with rectangular flange.
• RDMC_V: Straight discharge with circular flanges. Internally insulated.
• PA_V: Intake plenum with circular flanges.
Flanges in plastic material.
• RPM_V: Discharge plenum with rectangular flange. Internally insulated.
• PM_V: Discharge plenum with circular flanges. Internally insulated. Flanges in plastic material.
• KFV10: Circular flanges kit for intake/discharge plenum.
Discharge and intake grilles:
• GA: Intake grille with fixed louvres.
• GAF: Intake grille with fixed louvres with filter.
• GM: Discharge grille with adjustable louvres.
• SE: External air damper with manual control.
INSTALLATION ACCESSORIES
• BC: auxiliary condensate drain tray.
• DSC4: Condensate pump to overcome lifts.
• ZX: Feet for recessed installation.
HEATING ONLY COIL
• BV: 1 row heating only coil.
WATER VALVES
For main coil, 230V~50 Hz / 24V~50 Hz
• VCF43 / 4324: Kit composed of 3-way motorised valve with insulating casing, connections and insulated copper tubes.
• VCFD3 / 324: Kit composed of 2-way motorised valve with insulating casing, connections and insulated copper tubes.
For heating only coil, 230V~50 Hz / 24V~50 Hz
• VCF45 / 4543: Kit composed of 3-way motorised valve, with connections and insulated copper tubes.
• VCFD4 / 424: Kit composed of 2-way motorised valve, with connections and insulated copper tubes.
• VCF3X4: Valve kit for 4 pipe systems and fan coil units with single coil and 2 connections.
Kit composed of
special 3 way motorised valve with insulating casing, connections and insulated copper tubes.
Version VCF3X4L for left hand connection fan coils.
Version VCF3X4R for right hand connection fan coils.
Power supply 230V ~ 50Hz.
CONTROL PANELS
The complete characteristics of the control panels are described in the dedicated files.
Some control panels require combination with other accessories; consult the relevant documentation.
ACCESSORIES TO COMBINE TO CONTROL
PANELS
• SIT 3 - 5: Thermostat Interface Boards. Allows networking of fan coil units (10 max) controlled by a central panel (switch or thermostat).
SIT3: Controls the 3 speeds of the fan and must be installed on each fan coil unit on the network; receives controls from the switch or the
SIT5 board.
SIT5: Thermostat interface board. Allows a network of VED units (3 max) controlled by a single panel PXAE.
• SW3: Water temperature sensor for control panel PXAE.
• SWA: Air and water temperature sensor for control panel FMT21.
VARIABLE MULTI FLOW SYSTEM
VMF System: The complete characteristics of the
VMF system are described in the dedicated files.
Some VMF components require combination with other accessories; consult the relevant documentation.
Accessory Compatibility
PM000V ***
PM100V ***
PM200V ***
PM300V ***
RPM000V ***
RPM100V ***
RPM200V ***
RPM300V ***
RDMC000V
RDMC100V
RDMC200V
RDMC300V
BV030
BV130
BV230
BV162
KFV10
VMF-EO
VMF-E1
VMF-SW
VMF-SW1
VMF-E4/E4D
VMF-E5N/E5B
FMT10
FMT21
TPF
Mod.VED
RDA000V
RDA100V
RDA200V
RDA300V
RPA000V ***
RPA100V ***
RPA200V ***
RPA300V ***
RDAC000V
RDAC100V
RDAC200V
RDAC300V
PA000V ***
PA100V ***
PA200V ***
PA300V ***
030 040
• •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
130 140
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
230 240
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
330 340
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
GAF22
GAF32
GAF42
GAF62
GM22
GM32
GM42
GM62
SE20X ****
SE30X ****
SE40X ****
SE80X ****
ZX7
ZX8
Mod.VED
SWA
KTLP
PX
PX2 - PX2C6
PXAR
PXAE
WMT05
WMT06
WMT10
SW3
SIT3
SIT5
VCF43-4324 *
VCF45-4524 *
VCFD3-324 *
VCFD4-424 *
VCF3X4R
VCF3X4L
AMP
BC4 * / **
BC6 **
BC9 **
DSC4 **
GA22
GA32
GA42
GA62
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
030 040 130
• • •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
140 230
• •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
240 330
• •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
340
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
* The valve kits VCF and the drain pan BC4 cannot be installed together on the same fan coil unit.
** The accessory DSC4 is not compatible with AMP and BC4 - BC6 - BC9.
*** All the Plenums ( RPA_V; PA_V; RPM_V; PM_V ) have a circular push-outs
(Ø=150mm ) on both sides, which can be removed and used with accessories.
All the Plenums ( RPA_V; PA_V; RPM_V; PM_V ) can have intake/discharge either straight or downwards (straight or downwards with reference to horizontal installation).
**** Accessories SE must be combined with the feet ZX.
41
Technical data
Mod.
VED
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1) W
Heating capacity (70°C) (1) W
(1) W
(1) l/h
Water flow rate
Pressure drop
(1) l/h
(1) l/h
(1) kPa
(1) kPa
(1) kPa
(2) W
Heating capacity (50°C) (2) W
(2) W
(2) l/h
Vel.
L
H
M
L
H
M
M
L
H
L
H
H
M
030
3688
3374
1820
323
296
160
9
7
3
2180
1990
1100
279
-
-
-
-
-
-
-
-
-
030*
BV030
-
-
-
-
040
Water flow rate (2) l/h
(2) l/h
(2) kPa
(2) kPa
M
L
H
M
250
170
8
7 -
-
-
-
Pressure drop
(2) kPa L 3 -
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
(3) W H 2220
Heating capacity (70°C) (3) W M 2080
296
193
12
10
5
-
-
Water flow rate
(3) W
(3) l/h
(3) l/h
(3) l/h
(3) kPa
L
H
M
L
H
Pressure drop (3) kPa
(3) kPa
M
L
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
(4) W H
Total cooling capacity (4) W M
-
-
-
-
-
-
-
1590
196
183
140
8
7
5
-
-
-
-
-
-
-
Sensible cooling capacity
Water flow rate
Pressure drop
Air flow rate
Fans
High static pressure
Absorbed power
Max. input current
Sound power level (inlet+radiator)
Sound power level (outlet)
(4)
(4)
(4)
(4)
(4)
(4) l/h
(4) l/h
(4) kPa
(4)
(4)
(5)
W
W
W
W l/h kPa kPa m m m type n°
Pa
Pa
Pa
W
W
W
3
3
3
(A)
/h
/h
/h dB(A)
(5) dB(A)
(5) dB(A)
(5) dB(A)
(5) dB(A)
(5) dB(A)
L
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
H
M
L
1624
1454
990
1242
1116
750
279
250
170
9
7
3
285
256
161
1
61
50
21
59
38
23
0,37
54
52
44
50
48
40
1592
1416
984
1218
1094
745
274
244
169
9
7
3
280
250
160
1
61
50
21
59
38
23
0,37
54
52
44
50
48
40
52
44
50
48
40
58
38
23
0,37
54
1
61
50
21
296
193
14
12
5
277
249
160
1900
1720
1120
1350
1230
810
327
Water content
Water content (additional heat exchanger)
Coil connections
Coil connections (additional heat exchanger)
Speed connected l l
ø Gas (F)
ø Gas (F)
H
M
L
3/4"
-
V6
V4
V1
3/4"
1/2"
V6
V4
V1
3/4"
-
V6
V4
V1
Power supply
3916
3568
2366
343
313
207
12
10
4
2340
2130
1410
327
130
-
-
-
-
-
-
-
-
-
-
-
-
-
-
330*
BV162
-
-
-
-
760
633
16
13
9
16
13
9
6270
5580
4670
860
10507
9343
7813
921
819
685
624
499
31
26
13
3
26
18
4750
4290
3450
691
7909
7141
5800
684
616
499
-
-
-
-
-
-
-
-
-
-
-
-
-
-
230*
BV230
-
-
-
-
538
445
35
29
20
37
30
27
4320
3920
3230
588
7160
6500
5350
616
559
460
525
390
19
16
9
18
16
9
3940
3650
2710
566
6575
6089
4518
576
534
396
-
-
-
-
-
-
-
-
-
-
-
-
-
-
130*
BV130
-
-
-
-
480
358
27
23
13
26
22
13
3750
3480
2620
516
6289
5833
4397
551
511
385
76
53
34
0,41
55
2
60
50
26
53
47
50
48
42
480
358
31
27
15
433
397
287
2997
2790
2080
2090
1940
1440
515
-
-
-
-
-
-
-
-
-
3/4"
-
V6
V4
V1
76
53
34
0,41
55
2
60
50
26
53
47
50
48
42
469
349
31
27
15
423
388
280
2931
2727
2029
2169
1900
1400
504
3780
3596
2946
331
315
258
28
25
17
3/4"
1/2"
V6
V4
V1
140
-
-
-
-
-
-
-
-
-
230
525
390
23
20
11
420
386
280
3290
3050
2270
2370
2190
1610
566
53
47
50
48
42
75
52
34
0,41
55
2 centrifugal
2
60
50
26
64
50
32
93
57
43
0,58
57
54
49
42
49
44
538
445
44
36
25
590
524
417
3420
3130
2590
2700
2440
2000
588
3/4"
-
3/4"
-
V6
V4
V1
V6
V3
V1
230V/1/50Hz
-
-
-
-
-
-
-
-
-
93
57
43
0,58
57
2
64
50
32
54
49
42
49
44
530
430
42
35
23
582
513
412
3380
3080
2500
2600
2350
1900
581
4493
4171
3675
394
366
322
16
14
11
3/4"
1/2"
V7
V3
V1
240
92
57
43
0,58
57
2
63
50
32
54
49
42
49
44
624
499
37
31
16
570
509
406
4020
3630
2900
3015
2718
2200
691
-
-
-
-
-
-
-
-
-
3/4"
-
V6
V3
V1
330
104
75
63
0,66
58
3
66
50
33
55
38
54
51
34
-
-
-
-
-
-
-
-
-
760
633
18
14
10
805
704
572
5000
4420
4946
4380
3680
3738
3600
3670
3337,5 3280
2800 2720
860 851
753
619
18
14
9
790
695
568
3/4"
-
V7
V3
V1
104
75
63
0,66
58
3
66
50
33
55
38
54
51
34
5888
5499
4896
515
482
429
26
23
19
3/4"
1/2"
V7
V3
V1
340
103
74
63
0,66
58
3
64
50
34
55
38
54
51
34
824
685
26
21
16
775
685
563
5360
4790
3980
3990
3570
2950
922
-
-
-
-
-
-
-
-
-
3/4"
-
V7
V3
V1
H max. speed; M med. speed; L min. speed
Heating mode
2 pipes system configuration
(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C;
ΔT water 10°C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode
* 4 pipes system configuration (with additional heat exchanger) (BV)
(3)Room air temperature 20°C b.s.; Inlet water temperare 70°C;
ΔT water 10°C
Cooling mode (EUROVENT)
(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C;
ΔT water 5°C
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
VED30÷240
V1 V2 V3 V4 V5 V6 Speed
V1 V2 V3 V4 V5 V6 V7
L7 L6 L5 L4 L3 L2 L1
VED330÷340
Note: The speed of associates may differ from the standard factory configuration, for more information refer to the program selection and the technical documentation available on the website www.aermec.com
42
824
685
21
17
13
32
28
22
6550
5980
4970
922
10951
10017
8312
960
878
729
Dimensions (mm)
VED: 030 - 040 - 130 - 140 - 230 - 240 - 330 - 340
25
D
A
B
C
Asola 20x9
25
24
217
167 24
41
96
156
149
Ø20,5
Ø17,5
VED
C
D
A
B
Net weight mm mm mm mm kg
030
576
550
500
530
20
040
576
550
500
530
21
130
807
781
731
761
23
140
807
781
731
761
24
230
1027
1001
951
981
29,5
240
1027
1001
951
981
32
330
1148
1122
1072
1102
32,5
340
1148
1122
1072
1102
34
The technical data shown in this documentation is not binding.
Aermec S.p.A. reserves the right to make all modification deemed necessary for improving the product at any time.
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577 www.aermec.com
43
VED
Air handling terminal with cooling capacities from 8 to 18 kW
For ducted systems
AERMEC partecipates in the
EUROVENT programme for: FCP
Check ongoing validity of certificate online: www.eurovent-certification.com
• HORIZONTAL AND VERTICAL INSTALLATION
• VERSIONS FOR 2/4 PIPE SYSTEMS
• HEAT EXCHANGER ONLY WITH 1 OR 2 ROWS
• WIDE RANGE OF USEFUL STATIC PRESSURE
• 5 SPEED VENTILATION UNIT
• INSPECTIONABLE FAN UNIT
• CLASS G3 AIR FILTER
• COIL REVERSIBILITY
Choosing the unit
By appropriately combining the options available, it is possible to select the model that satisfies the specific system requirements.
Fields configurator:
1 2 3
❘
Code
❘
4
Size
5
❘
Main coil n°. rows
6
❘
Heating only coil n°. rows
1 2 3
❘
VED
4
❘
5
5
❘
3
6
2
❘
(VED532 = unit size 5, with Main Coil 3 Rows and Heating Coil 2 Rows)
Features
• Air handling terminal for ducted systems
• EUROVENT FCP Certification Program
• Horizontal and vertical installation
• Indoor installation
• Available in 4 sizes and 4 configurations
• Versions for 2 pipe systems with 3 or 4 row coil
• Versions for systems with 4 pipes with main coil with 3 or 4 rows and heating only coil with 1 or 2 rows
• Reversibility of the hydraulic connection in the installation phase
• Low pressure drop in the heat exchange coils
• 3-way valves accessories
• 2-way valves accessories for systems with variable water flow rate
• 5 speed fan unit (3 selectable)
• Wide range of useful static pressure
• Centrifugal fans in antistatic plastic. Due to their features, they allow to reduce the energy consumption with respect to normal fans
• Fans with wing-shaped profile studied to obtain high flow rate and static pressure performance and low noise emission at the same time
• Compatible with the VMF system
• Wide range of controls
• Wide range of accessories to satisfy all system requirements
• Rectangular flow flange already integrated into the framework
• Class G3 air filter with easy extraction and cleaning
• Internal insulation in Class 1 fire resistance
• IP20 protection rating
• Plastic augers, extractable for easy and efficient cleaning
• Easy installation and maintenance
• Full respect of the accident-prevention standards
44
Accessories
• RDA_V: Straight fitting with rectangular flange for ducting.
In galvanised sheet steel
• RPA_V: Intake plenum with rectangular flange for ducting.
In galvanised sheet steel
• PA_V: Intake plenum with circular flanges for ducting.
In galvanised sheet steel, the flanges are in plastic
• RPM_V: Flow plenum with rectangular flange for ducting.
In galvanised sheet steel, internally isolated.
• PM_V: Flow plenum with circular flanges for ducting
In galvanised sheet steel, internally isolated, the flanges are in plastic
• KFV: Circular flange kit for intake/flow plenum.
In plastic
• VCF4_C: Kit made up from motorised 3-way valves with isolating shell, fittings and isolated copper pipes. For main coils.
230V~50 Hz power supply
• VCF4_H: Kit made up from motorised 3-way valves, fittings and isolated copper pipes. For heating only coils. 230V~50 Hz power supply
• VCF2_C: Kit made up from motorised 2-way valves, with fittings and isolated copper pipes. For main coils. 230V~50 Hz power supply
• VCF2_H: Kit made up from motorised 2-way valves, with fittings and copper pipes.
For heating only coils. 230V~50 Hz power supply coupled to thermostats different to the VMF
System
• SIT5: Thermostat interface board.
Allows to realise a network of VED units
(max 3) controlled by a centralised PXAE panel
• SW3: Water minimum temperature probe to use with PXAE control panel.
CONTROL PANELS
The complete features of the control panels are described in the dedicated sheet.
Some control panels require coupling with other accessories, consult the relative documentation.
VARIABLE MULTI FLOW SYSTEM
VMF System: The complete fittings of the VMF
System management system are described in the dedicated sheet.
Some VMF components require coupling with other accessories, consult the relative documentation.
• VMF-SIT 3 : Thermostat Interface Board
VMF. Mandatory accessory on the VED unit supplied with VMF-E0 / E1 thermostat.
ACCESSORIES TO COUPLE WITH THE
CONTROL PANELS
• SIT3 : Thermostat interface board
Mandatory accessory on the VED units
Mod. VED
RDA 450 V
RDA 670 V
RPA 450 V
RPA 670 V
PA 450 V
PA 670 V
RPM 450 V
RPM 670 V
PM 450 V
PM 670 V
KFV
SW3
SIT 3*
SIT 5**
PXAE
WMT05
WMT06
WMT10
VCF45C
VCF45H
VCF47C
VCF47H
VCF25C
VCF25H
VMF-SIT3***
VMF-E0
VMF-E1
VMF-SW
VMF-SW1
VMF-E4/E4D
VMF-E5B
VMF-E5N
•
•
•
•
•
•
•
•
432
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
430
•
•
•
•
•
•
•
•
•
•
•
•
•
•
441
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
440
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
530
•
•
•
•
•
•
Accessories compatibility
532
•
540
•
541
•
630
•
• • •
•
• • •
•
• • •
•
• • •
• • •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
640
•
•
•
•
•
•
•
•
•
•
•
•
•
632
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
* SIT3
** SIT5
=Mandatory accessory on the VED units coupled to thermostats different to the VMF System
= Allows to realise a network of VED units (max 3) controlled by a centralised PXAE panel
*** VMF-SIT3 = Mandatory accessory for coupling with VMF-E0 or VMF-E1
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
641
•
•
•
•
•
•
•
•
•
•
•
•
•
732
•
•
•
•
•
•
•
•
•
•
•
•
•
730
•
•
•
•
•
•
•
•
•
•
•
•
•
741
•
•
•
•
•
•
•
•
•
•
•
•
•
740
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
45
Technical data
Mod.
VED
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1) W
Heating capacity (70°C)
Water flow rate
(1) W
(1) W
(1) l/h
(1) l/h
Pressure drop
Heating capacity (50°C)
Water flow rate
Pressure drop
(1) l/h
(1) kPa
(1) kPa
(1) kPa
(2) W
(2) W
(2) W
(2) l/h
(2) l/h
(2) l/h
(2) kPa
(2) kPa
(2) kPa
Vel.
430 432 440 441 530 532 540 541 630 632 640 641 730 732 740 741
H 15974 18110 17572 19908 27016 32688 28999 31706 -
M 13845 15358 16467 18586 22672 27744 25364 27650 -
L 10469 11445 13802 15377 18628 22454 21178 22883 -
H 1401
M 1214
L
H
M
918
19
14
-
-
-
-
-
1588
1347
1004
24
18
-
-
-
-
-
1541
1444
1211
21
18
-
-
-
-
-
1746
1630
1349
29
25
-
-
-
-
-
2370
1989
1634
58
43
-
-
-
-
-
2867
2434
1970
38
29
-
-
-
-
-
2544
2225
1858
67
55
-
-
-
-
-
2781
2425
2007
46
36
-
-
-
-
-
L
H
M
L
L 9
H 9470
M 8250
L 6200
H 1195
M 1058
805
17
11
7 -
-
-
-
-
-
-
-
11
10700 10420 11820 16070 17930 17280 19150 -
9130
6810
1378
1214
918
19
15
9
-
-
-
-
-
-
-
-
13
9780
8190
1335
1271
1060
16
15
11
-
-
-
-
-
-
-
-
18
11050
9170
1543
1469
1278
23
21
16
-
-
-
-
-
-
-
-
30
13500
11100
2155
1840
1529
48
36
26
-
-
-
-
-
-
-
-
19
14940
11980
2611
2195
1794
36
27
19
-
-
-
-
-
-
-
-
38
15120
12640
2382
2098
1789
57
44
33
-
-
-
-
-
-
-
-
26
16680
13840
2766
2448
2057
35
28
21 -
-
-
-
-
-
-
-
-
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
Heating capacity (70°C)
Water flow rate
Pressure drop
(3) W
(3)
(3) W
(3)
(3)
(3) l/h
(3) kPa
(3)
W l/h l/h kPa
H
M
L
H
M
L
H
M
-
-
-
-
-
-
-
-
12090
10725
8280
1060
940,7
726,2
18
14
-
-
-
-
-
-
-
-
8160
7480
6190
716
656
543
28
24
-
-
-
-
-
-
13540 -
12850 -
10720
1188
1127
940
22
20
-
-
-
-
-
-
8850
8520
7475
776
747
656
32
30
-
-
-
-
-
-
-
-
20513
17726
14665
1799
1555
1286
28
22
-
-
-
-
-
-
-
-
13750
12370
10770
1206
1085
945
28
23
-
-
-
-
-
-
-
-
22174
19726
16728
1945
1730
1467
33
26
-
-
-
-
-
-
-
-
14500
13300
11830
1272
1167
1038
30
26
(3) kPa L
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
(4) W
9 17 14 24 16 18 20 21
H 6950 6950 8010 8010 7760 7760 8970 8970 12530 12530 15180 15180 13850 13850 16080 16080
Total cooling capacity
Sensible cooling capacity
(4) W
(4) W
(4) W
(4) W
(4) W
M 6150 6150 7060 7060 7390 7390 8540 8540 10700 10700 12760 12760 12200 12200 14230 14230
L 4680 4680 5340 5340 6160 6160 7430 7430 8890 8890 10430 10430 10400 10400 11960 11960
H 5360 5360 5730 5730 6020 6020 6450 6450 10300 10300 10660 10660 11440 11440 11320 11320
M 4710 4710 5040 5040 5710 5710 6130 6130 8750 8750 8910 8910 9990 9990 9970 9970
L 3540 3540 3780 3780 4720 4720 5040 5040 7220 7220 7240 7240 8480 8480 8340 8340
Water flow rate
Pressure drop
Air flow rate
Fans
(4) l/h
(4) l/h
(4) l/h
(4) kPa
(4) kPa
(4) kPa m 3 /h m 3 /h m
3
/h type
H 1195 1195 1378 1378 1335 1335 1543 1543 2155 2155 2611 2611 2382 2382 2766 2766
M 1058 1058 1214 1214 1271 1271 1469 1469 1840 1840 2195 2195 2098 2098 2448 2448
L
H
M
805
17
13
805
17
13
918
22
17
918 1060 1060 1278 1278 1529 1529 1794 1794 1789 1789 2057 2057
22
17
21
19
21
19
28
25
28
25
48
36
48
36
41
30
41
30
58
46
58
46
45
37
45
37
L 8 8 10 10 12 12 19 19 26 26 21 21 35 35 27 27
H 1350 1250 1340 1250 1520 1460 1500 1460 2210 2110 2440 2110 2410 2350 2350 2350
M 1130 1060 1100 1060 1400 1360 1380 1360 1800 1730 2004 1730 2040 2000 2000 2000
L 790 750 780 750 1120 1060 1100 1060 1380 1340 1567 1340 1640 1600 1600 1600 centrifugal
High static pressure
Absorbed power
Max. input current n°
Pa
Pa
Pa
W
W
W
(A)
H
M
L
H
2
72
50
24
2
70
50
25
2
70
50
24
2
70
50
25
2
58
50
32
2
56
50
32
2
56
50
32
2
56
50
32
3
75
50
30
3
75
50
30
3
75
50
30
3
75
50
30
3
69
50
32
3
69
50
32
3
69
50
32
3
69
50
32
228 215 222 215 270 266 267 266 339 340 340 340 371 372 371 372
M 175 175 178 175 232 229 230 229 268 264 260 264 285 288 285 288
L 137 130 135 130 175 170 172 170 224 223 220 223 234 227 234 227
Sound power level (inle+radiator)
Sound power level (outlet)
Water content
Water content (additiona heat exchanger)
Coil connections
Coil connections (additiona heat exchanger)
Speed connected
(5) dB(A)
(5) dB(A)
(5) dB(A)
(5) dB(A)
(5) dB(A)
(5) dB(A) l l
ø Gas (F)
ø Gas (F)
H
M
L
H
M
L
H
M
53
57
42
49
53
38
61
57
51
57
53
47
62
59
53
58
55
49
62
59
53
58
55
49
68
64
59
64
60
55
68
64
59
64
60
55
68
66
62
64
62
58
68
66
62
64
62
58
3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4”
-
V5
V3
1/2”
V5
V3
-
V5
V3
1/2”
V5
V3
-
V5
V4
1/2”
V5
V4
-
V5
V4
1/2”
V5
V4
-
V5
V3
1/2”
V5
V3
-
V5
V3
1/2”
V5
V3
-
V5
V3
1/2”
V5
V3
-
V5
V3
1/2”
V5
V3
Power supply
L V1 V1 V1 V1 V2 V2 V2 V2 V1
230V/1/50Hz
V1 V1 V1 V1 V1 V1 V1
H max. speed; M med. speed; L min. speed
Heating mode
2 pipes system configuration
(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode
VED430÷741
V1 V2 V3 V4 V5
Speed
4 pipes system configuration (with additional heat exchanger) (EUROVENT)
(3)Room air temperature 20°C b.s.; Inlet water temperare 70°C; ΔT water 10°C
Cooling mode (EUROVENT)
(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; ΔT water 5°C
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
Note: The speed of associates may differ from the standard factory configuration, for more information refer to the program selection and the technical documentation available on the website www.aermec.com
46
=
Dimensional data (mm)
VED: 430 - 432 - 440 - 441 - 530 - 532 - 540 - 541
1158
1133
1053
1158
1133
1053
1104
1109
=
10
15
300
256
45
109
241
198
10
15
275
300
256
Ø16
45
109
241
198
275
Ø16
1104
1109
VED
Weight Kg
430
41
VED: 630 - 632 - 640 - 641 - 730 - 732 - 740 - 741
432
46
440
43
441
46
530
42
532
47
540
47
541
47
40
1558
1533
1453
10
40
15
351
307
280 316
46
109
247
287
326
Ø16
1504
1509
VED
Weight Kg
630
57
632
57
640
60
641
60
730
58
732
64
740
61
741
64
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577 www.aermec.com
47
VED_I
Fan coil unit with Brushless Inverter motor (EC) for ducted systems
Cooling capacities 0,99÷5,82kW
AERMEC
partecipates in the EUROVENT programme for: FCP
Check ongoing validity of certificate online: www.eurovent-certification.com
• HORIZONTAL OR VERTICAL INSTALLATION
• VERSIONS FOR 2/4 PIPE SYSTEMS
• 1 ROW HEATING ONLY COIL (ACCESSORY BV)
• LARGE RANGE OF AVAILABLE STATIC PRESSURE
• CENTRIFUGAL FANS INVERTER
• ACCESSIBLE FAN ASSEMBLY
• AIR FILTER CLASS G3
• REVERSIBLE COIL
Unit selection
By choosing the appropriate options it is possible to select the model to suit the specific system requirements.
Configuration fields:
1 2 3
❘
Code
❘
4
Size
❘
5
Main Coil
6
❘
Main coil only hot
❘
7
Inverter motor
Example:
1 2 3
❘
VED
4
❘
0
5
❘
3
6
0
❘
7
I
❘
Characteristics
• Ducted air conditioning terminal unit
• Internal installation
• 3 or 4 row coils for 2-pipe systems
• 3 row main coil and heating only coil accessory for 4-pipe systems
• Reversing of hydraulic connections side on site
• Low pressure drop heat exchanger
• 3-way valve accessory
• 2-way valve accessory for variable flow systems
• Centrifugal fans with motor inverter
• Large range of available static pressure
• Centrifugal fans in anti-static plastic material.
Their characteristics permit energy savings compared to conventional fans
• Fans with aerofoil profile designed to achieve high airflows and pressures whilst at the same time producing low noise
• Compatible with the VMF system
• Large range of controllers
• Large range of accessories to satisfy all installation requirements
• Discharge connection supplied loose
• Air filter Class G3, for easy removal and cleaning
• Internal insulation in Class 1 fire retardant material
• Protective rating IP20
• Fan housing in plastic material removable for easy and effective cleaning
• Ease of installation and maintenance
• Full compliance with safety standards.
48
Accessories
DUCTING ACCESSORIES
Plenum in galvanised sheet steel and connections:
• RDA_V: Straight intake connection with rectangular flange.
• RDAC_V: Straight intake connection with circular flanges.
• RPA_V: Intake plenum with rectangular flange.
• RDMC_V: Straight discharge with circular flanges. Internally insulated.
• PA_V: Intake plenum with circular flanges.
Flanges in plastic material.
• RPM_V: Discharge plenum with rectangular flange. Internally insulated.
• PM_V: Discharge plenum with circular flanges. Internally insulated. Flanges in plastic material.
• PMZ: Plenum with motorized dampers (for more details refer to the dedicated card).
• KFV10: Circular flanges kit for intake/discharge plenum.
Discharge and intake grilles:
• GA: Intake grille with fixed louvres.
Compatibilità accessori
ter.
• GM: Discharge grille with adjustable louvres.
• SE: External air damper with manual control.
INSTALLATION ACCESSORIES
• AMP: Hanging kit.
• BC: auxiliary condensate drain tray.
• DSC4: Condensate pump to overcome lifts.
• ZX: Feet for recessed installation.
HEATING ONLY COIL
• BV: 1 row heating only coil.
WATER VALVES
For main coil, 230V~50 Hz / 24V~50 Hz
• VCF43 / 4324: Kit composed of 3-way motorised valve with insulating casing, connections and insulated copper tubes.
• VCFD3 / 324: Kit composed of 2-way motorised valve with insulating casing, connections and insulated copper tubes.
For heating only coil, 230V~50 Hz / 24V~50 Hz
• VCF45 / 4543: Kit composed of 3-way motorised valve, with connections and insulated copper tubes.
• VCFD4 / 424: Kit composed of 2-way motorised valve, with connections and insulated copper tubes.
• VCF3X4: Valve kit for 4 pipe systems and fan coil units with single coil and 2 connections.
Kit composed of
special 3 way motorised valve with insulating casing, connections and insulated copper tubes.
Version VCF3X4L for left hand connection fan coils.
Version VCF3X4R for right hand connection fan coils.
Power supply 230V ~ 50Hz.
CONTROL PANELS
The complete characteristics of the control panels are described in the dedicated files.
Some control panels require combination with other accessories; consult the relevant documentation.
• WMT21: Electronic thermostat wall-mount installation
• SWAI: Air and water temperature sensor for
WMT21.
Variable Multi Flow System (VMF)
The complete characteristics of the VMF system are described in the dedicated files.
Some VMF components require combination with other accessories; consult the relevant documentation.
Mod.VED
RDA000V
RDA100V
RDA200V
RDA300V
RPA000V
RPA100V
RPA200V
RPA300V
RDAC000V
RDAC100V
RDAC200V
RDAC300V
PA000V
PA100V
PA200V
PA300V
PM000V
PM100V
PM200V
PM300V
PMZ
RPM000V
RPM100V
RPM200V
RPM300V
RDMC000V
RDMC100V
RDMC200V
RDMC300V
BV030
BV130
BV230
BV162
KFV10
WMT21
SWAI
VMF-E18
VMF-SW
VMF-SW1
VMF-E4
VMF-E4D
VMF-E5N
VMF-E5B
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
•
•
•
•
•
•
•
•
•
•
030I 040I 130I 140I 230I 240I 330I 340I
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• • • •
•
•
•
•
• •
• •
• •
• •
• •
• •
• •
• •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
GAF32
GAF42
GAF62
GM22
GM32
GM42
GM62
SE20X
SE30X
SE40X
SE80X
ZX7
ZX8
Mod.VED
VCF43-4324 (2)
VCF45-4524 (2)
VCFD3-324
(2)
VCFD4-424
(2)
VCF3X4R
VCF3X4L
AMP
BC4
BC6
BC9
DSC4
GA22
GA32
GA42
GA62
GAF22
(2)(3)
(3)
(3)
(3)
030I
•
•
•
•
•
•
•
•
•
•
•
•
•
040I
•
•
•
•
•
•
•
•
•
•
•
130I
•
•
•
•
•
•
•
•
•
•
•
•
140I
•
•
•
•
•
•
•
•
•
•
230I
•
•
•
•
•
•
•
•
•
•
•
•
240I
•
•
•
•
•
•
•
•
•
•
330I
•
•
•
•
•
•
•
•
•
•
•
•
340I
•
•
•
•
•
•
•
•
•
•
• •
(4)
(4)
(4)
(4)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
(1) All the Plenums ( RPA_V; PA_V; RPM_V; PM_V ) have a circular push-outs (Ø=150mm ) on both sides, which can be removed; All the Plenums can have intake/discharge either straight or downwards (straight or downwards with reference to horizontal installation).
(2) The valve kits VCF and the drain pan BC4 cannot be installed together on the same fan coil unit.
(3) The accessory DSC4 is not compatible with AMP and BC4 - BC6 - BC9.
(4) Accessories SE must be combined with the feet ZX
49
Technical data
Mod.
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
Heating capacity (70°C)
Water flow rate
Pressure drop
Heating capacity (50°C)
Water flow rate
(1) W
(1) W
(1) W
(1) l/h
(1)
(1)
(1)
(1)
(2)
VED
l/h l/h kPa kPa
(1) kPa
(2) W
(2) W
(2) W
(2) l/h l/h
Vel.
30I 030I* 40I
BV030
H 3688
M 3374
-
-
3916
3568
130I
6289
5833
130*
BV130
-
-
140I
6575
6089
230I
7160
6500
230*
BV230
-
-
240I
7909
7141
330I
10507
9343
330*
BV162
-
-
340I
10951
10017
L
H
M
L
H
M
1820
323
296
160
9
7
-
-
-
-
-
-
2366 4397
343 551
313
207
12
10
511
385
26
22
-
-
-
-
-
-
4518 5350
576 616
534
396
18
16
559
460
37
30
-
-
-
-
-
-
5800 7813
684 921
616
499
3
26
819
685
16
13
-
-
-
-
-
-
8312
960
878
729
L
H
M
L
H
M
3
2180
1990
1100
279
250
-
-
-
-
-
4
2340
2130
1410
327
296
13
3750
3480
2620
516
480
-
-
-
-
-
9
3940
3650
2710
566
525
27
4320
3920
3230
588
538
-
-
-
-
-
18
4750
4290
3450
691
624
9
6270
5580
4670
860
760
-
-
-
-
-
-
32
28
22
6550
5980
4970
922
824
Pressure drop
(2) l/h
(2) kPa
(2) kPa
L
H
M
170
8
7
-
-
-
193
12
10
(2) kPa L 3 -
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
5
358
27
23
13 -
-
-
-
390
19
16
9
445
35
29
20 -
-
-
-
499
31
26
13
633
16
13
9 -
-
-
-
685
21
17
13
Heating capacity (70°C)
Water flow rate
(3) W
(3) W
(3) W
(3) l/h
(3) l/h
(3) l/h
H
M
L
H
M
L
-
-
-
-
-
-
2220
2080
1590
196
183
140
-
-
-
-
-
-
-
-
-
-
-
-
3780
3596
2946
331
315
258
-
-
-
-
-
-
-
-
-
-
-
-
4493
4171
3675
394
366
322
-
-
-
-
-
-
-
-
-
-
-
-
5888
5499
4896
515
482
429
Pressure drop
(3) kPa
(3) kPa
(3) kPa
H
M
L
-
-
-
8
7
5
-
-
-
-
-
-
28
25
17
-
-
-
-
-
-
16
14
11
-
-
-
-
-
-
26
23
19
-
-
-
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
Total cooling capacity
(4) W
(4) W
H
M
1624
1454
1592
1416
1900
1720
2997
2790
2931
2727
3290
3050
3420
3130
3380
3080
4020
3630
5000
4420
4946
4380
5360
4790
-
-
-
-
-
-
Sensible cooling capacity
Water flow rate
Pressure drop
Air flow rate
Fans
High static pressure
Absorbed power
Max. input current
Sound power level (inlet+radiator)
Sound power level (outlet)
Water content
Coil connections
Coil connections (additiona heat exchanger)
Signal 0-10V
Power supply
(4)
(4)
(5)
W
(4) W
(4) W
(4) W l/h
(4) l/h
(4) l/h
(4) kPa
(4) kPa
(4) kPa m
3
/h m
3
/h m
3
/h type n°
Pa
Pa
Pa
W
W
W
(A)
(5) dB(A)
(5) dB(A) dB(A)
(5) dB(A)
(5) dB(A)
(5) dB(A) l
ø Gas (F)
ø Gas (F)
L 990 984 1120 2080 2029 2270 2590 2500 2900 3680 3600 3980
H 1242 1218 1350 2090 2169 2370 2700 2600 3015 3738 3670 3990
M 1116 1094 1230 1940 1900 2190 2440 2350 2718 3337,5 3280 3570
L
H
750
279
M 250
L 170
745
274
244
169
9
810 1440 1400 1610 2000 1900 2200 2800 2720 2950
327 515 504 566 588 581 691 860 851 922
296
193
14
480
358
31
469
349
31
525
390
23
538
445
44
530
430
42
624
499
37
760
633
18
753
619
18
824
685
26 H
M
L
9
7
3
H 285
7
3
280
12
5
277
27
15
433
27
15
423
20
11
420
36
25
590
35
23
582
31
16
570
14
10
805
14
9
790
21
16
775
M
L
H
M
L
H
M
L
256
161
1
61
50
250
160
1
61
50
249
160
1
61
50
397
287
2
60
50
388
280
2
60
50
386
280
2
60
50
524
417 centrifugal
2
64
50
513
412
2
64
50
509
406
2
63
50
704
572
3
66
50
695
568
3
66
50
685
563
3
64
50
H
M
L
H
M
L
21
36
29
12
21
36
29
12
21
36
29
12
26
45
33
17
26
45
33
17
26
45
33
17
0,33 0,33 0,33 0,41 0,41 0,41
54 54 54 55 55 55
52
39
52
44
52
39
53
45
53
47
53
45
32
53
40
24
0,5
57
54
44
32
53
40
24
0,5
57
54
49
32
53
40
24
0,5
57
54
44
33
86
60
35
0,5
58
55
38
33
86
60
35
0,5
58
55
38
55
38
50
48
50
48
50
48
50
48
50
48
50
48
52
49
42
49
52
49
54
51
54
51
54
51
34
1,11
40 34
1,48
39
1,5
42 39 39
1,48 1,48
44 39 34
1,48 2,52
34 34
3,4
3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"
1/2" 1/2" 1/2" 1/2" -
H 9V 9V 9V 9V 9V 9V 9V 9V 9V 9V 9V 9V
M 8,2V 8,2V 8,2V 8,2V 8,2V 8,2V 8,2V 8,2V 7,8V 7,8V 7,8V 7,8V
L 5,4V 5,4V 5,4V 5,8V 5,8V 5,8V 6,6V 6,6V 6,2V 6,2V 6,2V 6,6V
230V/1/50Hz
34
86
60
35
0,5
58
H max. speed; M med. speed; L min. speed
Heating mode
2 pipes system configuration
(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode
* 4 pipes system configuration with additional heat exchanger (BV)
(3)Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C
Cooling mode (EUROVENT)
(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; ΔT water 5°C
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
Note: For more information refer to the program selection and the technical documentation available on the website www.aermec.com
50
Dimensional data (mm)
VED: 030I - 040I - 130I - 140I - 230I - 240I - 330I - 340I
25
D
A
B
C
Asola 20x9
25
24
217
167 24
41
96
156
149
Ø20,5
Ø17,5
VED
C
D
A
B
Net weight mm mm mm mm
Kg
030I
576
550
500
530
20
040I
576
550
500
530
21
130I
807
781
731
761
23
140I
807
781
731
761
24
230I
1027
1001
951
981
29,5
240I
1027
1001
951
981
32
330I
1148
1122
1072
1102
32,5
340I
1148
1122
1072
1102
34
The technical data in this document is not binding. Aermec S.p.A. reserves the right to make any changes at any time deemed necessary for product improvement.
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Telephone 0442633111 - Telefax 044293730 www.aermec.com
51
VED_I
Fan coil unit with Brushless Inverter motor (EC) for ducted systems
Cooling capacities 8÷10kW
AERMEC
partecipates in the EUROVENT programme for: FCP
Check ongoing validity of certificate online: www.eurovent-certification.com
• HORIZONTAL OR VERTICAL INSTALLATION
• VERSIONS FOR 2/4 PIPE SYSTEMS
• 1 -2 ROW HEATING ONLY COIL
• LARGE RANGE OF AVAILABLE STATIC PRESSURE
• CENTRIFUGAL FANS INVERTER
• ACCESSIBLE FAN ASSEMBLY
• AIR FILTER CLASS G3
• REVERSIBLE COIL
Unit selection
By choosing the appropriate options it is possible to select the model to suit the specific system requirements.
Configuration fields:
1 2 3
❘
Code
Example:
1 2 3
❘
VED
❘
4
Size
4
❘
5
❘
5
Main Coil
5
❘
3
6
❘
Main coil only hot
6
2
❘
❘
7
Inverter motor
7
I
❘
Characteristics
• Ducted air conditioning terminal unit
• Internal installation
• 3 row main coil and heating only coil accessory for 4-pipe systems
• Versions for systems with 4 pipes with main coil with 3 or 4 rows and heating only coil with 1 or 2 rows
• Reversibility of the hydraulic connection in the installation phase
• Low pressure drop in the heat exchange coils
• 3-way valves accessories
• 2-way valves accessories for systems with variable water flow rate
• Centrifugal fans with motor inverter
• Wide range of useful static pressure
Centrifugal fans in antistatic plastic. Due to their features, they allow to reduce the energy consumption with respect to normal fans
• Fans with wing-shaped profile studied to obtain high flow rate and static pressure performance and low noise emission at the same time
• Compatible with the VMF system
• Wide range of controls
• Wide range of accessories to satisfy all system requirements
• Rectangular flow flange already integrated into the framework
• Class G3 air filter with easy extraction and cleaning
• Internal insulation in Class 1 fire resistance
• IP20 protection rating
• Plastic augers, extractable for easy and efficient cleaning
• Easy installation and maintenance
• Full respect of the accident-prevention standards
52
Accessoires
Mod. VED
RDA 450 V
RDA 670 V
RPA 450 V
RPA 670 V
PA 450 V
PA 670 V
RPM 450 V
RPM 670 V
PM 450 V
PM 670 V
PMZ
KFV
VCF45C
VCF45H
VCF47C
VCF47H
VCF25C
VCF25H
VMF-E18
VMF-SW
VMF-SW1
VMF-E4
VMF-E4D
VMF-E5B
VMF-E5N
• RDA_V: Straight fitting with rectangular flange for ducting.
In galvanised sheet steel
• RPA_V: Intake plenum with rectangular flange for ducting.
In galvanised sheet steel
• PA_V: Intake plenum with circular flanges for ducting.
In galvanised sheet steel, the flanges are in plastic
• RPM_V: Flow plenum with rectangular flange for ducting.
In galvanised sheet steel, internally isolated.
• PM_V: Flow plenum with circular flanges for ducting
• PMZ: plenum con amortiguadores motorizados (para más detalles consulte la tarjeta dedicada).
In galvanised sheet steel, internally isolated, the flanges are in plastic
• KFV: Circular flange kit for intake/flow plenum.
In plastic
• VCF4_C: Kit made up from motorised
3-way valves with isolating shell, fittings and isolated copper pipes. For main coils.
230V~50 Hz power supply
• VCF4_H: Kit made up from motorised
3-way valves, fittings and isolated copper pipes. For heating only coils.
230V~50 Hz power supply
• VCF25C: Kit made up from motorised
2-way valves, with fittings and isolated copper pipes. For main coils. 230V~50
Hz power supply
• VCF25H: Kit made up from motorised
2-way valves, with fittings and copper pipes.
For heating only coils. 230V~50 Hz power supply
• WMT21: Electronic thermostat wallmount installation
• SWAI: Water minimum temperature probe to use with WMT21 control panel.
VARIABLE MULTI FLOW SYSTEM
VMF System: The complete fittings of the
VMF System management system are described in the dedicated sheet.
Some VMF components require coupling with other accessories, consult the relative documentation.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
530I
•
•
•
•
•
532I
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
540I
•
•
•
•
•
541I
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
730I
•
•
•
•
•
•
•
732I
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
740I
•
•
•
•
•
•
•
741I
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
53
Technical data
Mod.
VED
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
Heating capacity (70°C)
(1) W
(1) W
Water flow rate
(1) W
(1) l/h
(1) l/h
(1) l/h
Pressure drop
Heating capacity (50°C)
Water flow rate
(1) kPa
(1) kPa
(1) kPa
(2) W
(2) W
(2) W
(2) l/h
(2) l/h
Vel.
M
L
H
M
L
H
H
M
L
H
M
L
H
M
530I
17572
16467
13802
1541
1444
1211
21
18
13
10420
9780
8190
1335
1271
532I
Pressure drop
Pressure drop
(2) l/h
(2) kPa
(2) kPa
(2) kPa
(3) l/h
(3) kPa
(3) kPa
(3) kPa
L
H
M
L
L
H
M
L
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
(4) W H
Total cooling capacity (4) W M
1060
16
15
11
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
Heating capacity (70°C)
(3) W
(3) W
H
M
-
-
13540
12850
Water flow rate
(3) W
(3) l/h
(3) l/h
L
H
M
-
-
-
10720
1188
1127
-
-
-
940
22
20
14
-
-
-
-
Sensible cooling capacity
Water flow rate
(4)
(4)
(4)
(4)
W
W
W
(4) W
(4) l/h
(4) l/h
(4) l/h kPa
L
H
M
L
H
M
L
H
7760
7390
6160
6020
5710
4720
1335
1271
1060
21
7760
7390
6160
6020
5710
4720
1335
1271
1060
21
Pressure drop
Air flow rate
M
L
H
M
L
19
12
1520
1400
1120
19
12
1460
1360
1060
Fans
High static pressure
Absorbed power
Sound power level (inlet+radiator)
Sound power level (outlet)
Coil connections
Coil connections (additiona heat exchanger)
Signal 0-10V
(4) kPa
(4) kPa m3/h m3/h m3/h type n°
Pa
Pa
Pa
W
W
W
(5) dB(A)
(5) dB(A)
(5) dB(A)
(5) dB(A)
(5) dB(A)
(5) dB(A)
ø Gas (F)
ø Gas (F)
H
M
L
H
M
L
H
M
L
H
M
L
H
M
2
58
50
32
205
170
115
62
59
53
58
55
49
3/4”
-
9V
8,4V
2
56
50
32
185
163
106
3/4”
1/2”
9V
8,4V
L 6,6V 6,6V
Power supply
-
-
-
-
-
-
-
-
-
-
-
-
-
-
H max. speed; M med. speed; L min. speed
Heating mode
2 pipes system configuration
(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode
4 pipes system configuration (with additional heat exchanger) (EUROVENT)
(3)Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C
Cooling mode (EUROVENT)
(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; ΔT water 5°C
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
Note: For more information refer to the program selection and the technical documentation available on the website www.aermec.com
54
13850
12200
10400
11440
9990
8480
2382
2098
1789
58
46
35
2350
2000
1600
3
69
50
32
363
240
138
22174
19726
16728
1945
1730
1467
33
26
20
732I
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
541I
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
8850
8520
7475
776
747
656
32
30
24
56
50
32
185
163
106
8970
8540
7430
6450
6130
5040
1543
1469
1278
28
25
19
1460
1360
46
35
2410
2040
1060 centrifugal
1640
2 3
13850
12200
10400
11440
9990
8480
2382
2098
1789
58
69
50
32
370
245
140
64
66
62
64
62
3/4”
1/2”
9V
8,4V
58
3/4”
-
9V
7,6V
6,6V 6,2V
230V/1/50Hz
-
-
-
-
-
-
-
-
-
730I
38
17280
15120
12640
2382
2098
1789
57
44
33
28999
25364
21178
2544
2225
1858
67
55
49
3/4”
-
9V
8,4V
2
56
50
32
205
170
115
62
59
53
58
55
6,6V
8970
8540
7430
6450
6130
5040
1543
1469
1278
28
25
19
1500
1380
1100
-
-
-
-
-
-
-
-
-
540I
18
11820
11050
9170
1543
1469
1278
23
21
16
19908
18586
15377
1746
1630
1349
29
25
3/4”
1/2”
9V
7,6V
6,2V
58
3/4”
-
9V
7,6V
3
69
50
32
370
245
140
68
66
62
64
62
6,2V
16080
14230
11960
11320
9970
8340
2766
2448
2057
45
37
27
2350
2000
1600
-
-
-
-
-
-
-
-
-
740I
26
19150
16680
13840
2766
2448
2057
35
28
21
31706
27650
22883
2781
2425
2007
46
36
16080
14230
11960
11320
9970
8340
2766
2448
2057
45
37
27
2350
2000
1600
3
69
50
32
363
240
138
14500
13300
11830
1272
1167
1038
30
26
21
741I
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3/4”
1/2”
9V
7,6V
6,2V
Dimensional data (mm)
VED: 530I - 532I - 540I - 541I
=
1158
1133
1053
1158
1133
1053
1109
=
10
15
300
256
45
109
241
198
275
10
15
300
256
Ø16
45
109
241
198
275
Ø16
1104
1109
VED
Weight Kg
VED: 730I - 732I - 740I - 741I
530I
42
532I
47
540I
44
541I
47
40
1558
1533
1453
10
40
15
351
307
280 316
46
109
247
287
326
Ø16
1504
1509
VED
Weight Kg
730I
58
732I
58
740I
61
741I
61
The technical data in this document is not binding. Aermec S.p.A. reserves the right to make any changes at any time deemed necessary for product improvement.
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577 www.aermec.com
55
VEC
Cassette type fancoil Coanda-effect
Installation in false ceilingsInstallation in false ceilings
Aermec
participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com
Features
VEC: Fan coil for ambient air treatment during the summer. The air is delivered into the room via vents which, thanks to the
COANDA effect, make the air jet adhere to the ceiling.
• Installation in false ceilings
• Compatible with VMF System
• Grille with suction and adjustable delivery vents with Coanda effect (compulsory accessory).
• 3-row coil
Accessoires
• Reduced pressure drops across heat exchangers
• For systems with fixed and variable delivery
• EUROVENT certified
• 3-speed fan unit
• Quiet operation
• Motors with permanently connected condensers
• Air filter easily removed and cleaned
• Internal insulation and air filter of Class 1 fire resistance
• Removable shrouds for easy, effective cleaning
• Reversibility of the water connections during installation
• Broad range of controls and accessories
• Easy installation and maintenance
• Full compliance with safety regulations
• For possible heat mode functioning, refer to the technical manual notes.
Compulsory accessories:
the following are essential for the functioning of the units:
• VEC_GL: air suction and delivery grille with adjustable Coanda-effect vents. White RAL 9010.
Accessories:
• AMP: kit for wall-mounting installation.
• BC5: auxiliary condensate drain tray.
• BV: Single row hot water coil.
• DSC4: condensate drainage device for use when natural run-off is not possible.
• SIT 3-5: thermostat interface cards. These allow you to create a network of fan coils (max. 10), commanded from a centralised panel (selector or thermostat).
SIT3: commands the 3 fan speeds, and must be installed on each fan coil in the network; receives the commands from the selector or SIT5 card.
SIT5: commands the 3 fan speeds and up to 2 valves
(4-pipe systems); conveys the thermostat commands to the fan coil network.
• SW3: water temperature probe, allowing the implementation of automatic season changeover for those electronic thermostats equipped with water side changeover.
• SWA: SWA external probe accessory (length L = 6m).
Detects the ambient air temperature if connected to the connector (A) of the panel FMT21; in this case the ambient air temperature probe built into the panel will be automatically disabled. Detects the temperature of the water in the system to allow ventilation consent if connected to the connector (W) of the panel FMT21. Two SWA probes may be simultaneously connected to the panel FMT21.
• VCF: kit consisting of a 3-way motorised valve, and copper couplings and pipes. For 3-row and 1-row coils (BV). Versions with 230V and 24V~50Hz power supply.
• VCFD: Kit consisting of a 2-way motorised valve, and copper couplings and pipes. For 3-row and 1-row coils (BV). Versions with 230V and 24V~50Hz power supply.
• Control panel and VMF system: the features of the control panels are described in the relevant card.
Accessoires for heating mode
• RX: Armoured electric coil with safety thermostat.
(Requires a thermostat with heater management).
• PXAR: Electronic thermostat with thermostated or continuous ventilation.
• PCR1: Galvanised plate protection for the controls and the electrical element
• BV: Single row hot water coil.
• VCF: the kit contains a motorised 3-way valve with insulating shell, plus coupling and pipes in insulated copper. For
3-row.
• VCFD: Kit consisting of powered 2-way valve, copper couplings and pipes. For 3 row
VEC
(Standard coil)
VEC
(increased coil)
Compulsory accessoires
VEC20GL
VEC30GL
VEC40GL
BC5
DSC4
SIT3
SIT5
(1)
SW3
SWA
VCF41
(standard coil)
VCF42
(increased coil)
VCF4124
(standard coil)
VCF4224
(increased coil)
VCFD1
(standard coil)
VCFD2
(increased coil)
VCFD124
(standard coil)
VCFD224
(increased coil)
20 30 40 50
24 34 44 54
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
VEC
(Standard coil)
VEC
(increased coil)
Control panel
FMT10
FMT21
KTLP
PX2
PX2C6
PX
PXAE
TPF
TF1
WMT05
WMT06
WMT10
VMF-System
VMF-E4 / E4D
VMF-E0 / E1
VMF-E5B / E5N
VMF-SW
VMF-SW1
20 30 40 50
24 34 44 54
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
VEC
(Standard coil)
VEC
(increased coil)
Accessoires for heating mode
RX22
RX32
(2)
(2)
•
RX42
RX52
(2)
(2)
PXAR
PCR1
BV122
BV132
BV142
(2)
(2)
(2)
(2)
(2)
•
•
•
VCF44
VCF4424
VCFD4
VCFD424
20
24
(2)(3) •
(2)(3) •
(2)(3) •
(2)(3) •
30
34
•
•
•
•
•
•
•
•
40
44
•
•
•
•
•
•
•
•
50
54
•
•
•
•
•
•
•
•
(1) DSC4 The accessory is not compatible with the BC5, and VMF system.
(2) See notes and warnings in the technical booklet
(3) only for accessory coil BV 1R
56
Technical data
Mod. VEC
COOLING PERFORMANCE
Total cooling capacity
Sensible cooling capacity
Water flow rate
Pressure drop
Air flow rate
Fans
Absorbed power
Max. input current
Sound power level
Sound pressure level
Water content
Coil connections
Speed connected
Power supply
(2)
(2)
(2)
(3)
(3)
(3)
A dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)
W
W
W m 3 /h type n°
(1) W
(1) W
(1) W
(1) W
(1) W
(1) W
(1) l/h
(1) l/h
(1) l/h
(1) kPa
(1) kPa
(1) kPa m 3 /h m
3
/h l
ø
Vel.
H
M
L
H
M
L
H
M
L
H
M
L
L
H
M
L
H
M
L
H
M
H
M
L
H
M
L
20
1320
1080
800
1080
880
640
227
186
138
5
4
2
247
167
130
1
25
22
19
0,12
48
42
35
39,5
33,5
26,5
0,79
1/2"G
V3
V2
V1
24
1522
1076
877
1147
800
667
262
185
151
3
2
1
247
167
130
1
25
22
19
0,12
48
42
35
39,5
33,5
26,5
0,79
1/2"G
V3
V2
V1
30
1950
1640
1370
1530
1280
1050
335
282
236
13
11
6
383
309
241
0,21
49
43
37
2
44
33
25
40,5
34,5
28,5
1,11
1/2"G
V3
V2
V1
34
2471
2140
1789
1775
1510
1257
425
368
308
8
6
5
383
309
241 centrifugal
2
44
33
25
0,21
49
43
37
40,5
34,5
28,5
1,11
1/2"G
V3
V2
V1
230V/1/50Hz
40
2980
2470
1980
2410
1980
1580
513
425
341
11
9
6
511
406
306
0,28
48
43
38
2
57
43
30
39,5
34,5
29,5
1,48
3/4"G
V3
V2
V1
44
3907
3335
2552
2737
2421
1909
672
574
439
22
17
10
511
406
306
2
57
43
30
0,28
48
43
38
39,5
34,5
29,5
1,48
3/4"G
V3
V2
V1
50
H max. speed; M med. speed; L min. speed
Cooling mode (VEC 20 - 30 - 40 - 50 EUROVENT)
(1) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C
(2) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(3) Sound pressure level (A-weighted) measured in the room with volume V=85m 3 , reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Heating
See notes and warnings in the technical booklet.
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com
Dimensions (mm)
VEC_GL (Compulsory accessory)
VEC20GL
VEC30GL
VEC40GL
3610
3170
2350
2590
2270
1680
621
545
404
15
10
6
613
529
371
2
67
46
34
0,35
53
50
43
44,5
41,5
34,5
1,48
3/4"G
V3
V2
V1
54
4282
4000
2995
2909
2437
1785
737
688
515
30
27
16
613
529
371
0,35
53
50
43
2
67
46
34
44,5
41,5
34,5
1,48
3/4"G
V3
V2
V1
Ø262
B
E
595
C
D
15
A
A
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.
895 1195
Dimensions VEC + VEC_GL (maximum dimensions)
Mod.
Height
Widht
Depth
Weight (VEC)
Weight (VEC_GL)
VEC
VEC
(A) mm
(B) mm
(C) mm kg kg
20/24
20GL
283
595
595
15,5
3,7
30/34
30GL
283
895
595
20,6
5,7
Dimensions VEC + VEC_GL (Dimensions for installation)
Mod.
Height
Widht
Depth
VEC
VEC
(A) mm
(D) mm
(E) mm
20/24
20GL
283
574
574
30/34
30GL
283
574
874
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577 www.aermec.com
40/44
40GL
283
1195
595
24,7
7
40/44
40GL
283
574
1174
50/54
40GL
283
1195
595
24,7
7
50/54
40GL
283
574
174
57
VEC_I
Cassette type fancoil Coanda-effect, with Brushless Inverter motor (EC)
Installation in false ceilings
Aermec
participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com
Features
VEC_I: Fan coil for ambient air treatment during the summer. The air is delivered into the room via vents which, thanks to the
COANDA effect, make the air jet adhere to the ceiling.
• Installation in false ceilings
• Compatible with VMF System
• Grille with suction and adjustable delivery vents with Coanda effect (compulsory accessory).
• Unit with standard coil (20
÷50)
• Unit with increased coil (24 ÷54)
• Reduced pressure drops across heat exchangers
• For systems with fixed and variable delivery
• Fan unit with Brushless motor (continuous
0-100% speed variation)
• Quiet operation
• Air filter easily removed and cleaned
• Internal insulation and air filter of Class 1 fire resistance
• Reversibility of the water connections during installation
• Broad range of controls and accessories
• Easy installation and maintenance
• Full compliance with safety regulations
• For possible heat mode functioning, refer to the technical manual notes.
Accessori
Compulsory accessories:
the following are essential for the functioning of the units:
• VEC_GL: air suction and delivery grille with adjustable Coanda-effect vents.
White RAL 9010.
Accessories:
• BC5: auxiliary condensate drain tray.
• BV: Single row hot water coil.
• DSC4: condensate drainage device for use when natural run-off is not possible.
• VCF: kit consisting of a 3-way motorised valve, and copper couplings and pipes. For
3-row and 1-row coils (BV). Versions with
230V and 24V~50Hz power supply.
• VCFD: Kit consisting of a 2-way motorised valve, and copper couplings and pipes. For
3-row and 1-row coils (BV). Versions with
230V and 24V~50Hz power supply.
• Control panel and VMF System: the characteristics are described on the appropriate card.
Accessories for heating mode
• BV: Single row hot water coil.
• VCF: the kit contains a motorised 3-way valve with insulating shell, plus coupling and pipes in insulated copper Versions with 230V and 24V~50Hz power supply.
• VCFD: Kit consisting of powered 2-way valve, copper couplings and pipes. For 3 row. Versions with 230V and 24V~50Hz power supply.
VEC_I
(standard coil)
VEC_I
(increased coil)
Compulsory accessories
VEC20GL
VEC30GL
VEC40GL
BC5
DSC4
VCF41
(standard coil)
VCF42
(increased coil)
(1)
VCF4124
(standard coil)
VCF4224
(increased coil)
20 30 40 50
24 34 44 54
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
VEC_I
(standard coil)
VEC_I
(increased coil)
VCFD1
(standard coil)
VCFD2
(increased coil)
VCFD124
(standard coil)
VCFD224
(increased coil)
Control panel
WMT20
VMF-System
VMF-E4 / E4D
VMF-E18
VMF-E5B / E5N
•
•
•
•
20 30 40 50
24 34 44 54
•
•
•
•
•
•
•
•
•
•
•
•
VEC_I
(standard coil)
VEC_I
(increased coil)
VMF-SW
VMF-SW1
•
•
•
•
•
•
•
•
•
•
•
•
20 30 40 50
24 34 44 54
•
•
•
•
•
•
Accessory dedicated to heating mode
BV122
BV132
(2)
(2)
•
•
BV142
(2)
VCF44
VCF4424
VCFD4
VCFD424
(2)(3)
(2)(3)
(2)(3)
(2)(3)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
(1) DSC4 The accessory is not compatible with the basins BC5, and VMF system.
(2)
See notes and warnings in the technical booklet.
(3) only for accessory coil BV 1R
58
Technical data
Mod. VEC_I
COOLING PERFORMANCE
Total cooling capacity
Sensible cooling capacity
Water flow rate
Pressure drop
Air flow rate
Fans
Absorbed power
Max. input current
Sound power level
Sound pressure level
Water content
Coil connections
Speed connected
(2)
(2)
(2)
(3)
(3)
(3)
(1) W
(1) W
(1) W
(1) W
(1) W
(1) W
(1) l/h
(1) l/h
(1) l/h
(1) kPa
(1) kPa
(1) kPa m 3 /h m
3
/h m 3 /h type n°
W
W
W
A dB(A) dB(A) dB(A) dB(A) dB(A) l dB(A)
ø
Vel.
H
M
L
H
M
L
H
M
L
H
M
L
L
H
M
L
H
M
L
H
M
H
M
L
H
M
L
20I
1320
1080
800
1080
880
640
227
186
138
4,6
4
2
247
194
130
1
12
8
5
0,11
48
42
35
39,5
33,5
26,5
0,79
1/2"G
5,4V
4,2V
2,6V
24I
1522
1224
877
1147
908
667
262
211
151
3
2
1
247
194
130
1
12
8
5
0,11
48
42
35
39,5
33,5
26,5
0,79
1/2"G
5,4V
4,2V
2,6V
30I
1950
1640
1370
1530
1280
1050
335
282
236
13,3
11
6
383
309
241
2
10
10
10
0,11
49
43
37
40,5
34,5
28,5
1,11
1/2"G
5V
3,8V
2,8V
34I
10
10
10
0,11
49
43
37
40,5
34,5
308
8
6
4
383
309
241 centrifugal
2
2471
2140
1789
1775
1510
1257
425
368
28,5
1,11
1/2"G
5V
3,8V
2,8V
230V/1/50Hz
40I
2980
2470
1980
2410
1980
1580
513
425
341
11,3
9
6
511
406
306
2
17
9
6
0,14
48
43
38
39,5
34,5
29,5
1,48
3/4"G
5,1V
3,9V
2,8V
44I
3907
3335
2552
2737
2421
1909
672
574
439
22
16
9
511
406
306
2
17
9
6
0,14
48
43
38
39,5
34,5
29,5
1,48
3/4"G
5,1V
3,9V
2,8V
50I
Power supply
H max. speed; M med. speed; L min. speed
Cooling mode (VEC 20I - 30I - 40I - 50I EUROVENT)
(1) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C
(2) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(3) Sound pressure level (A-weighted) measured in the room with volume V=85m
3
, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Heating
See notes and warnings in the technical booklet.
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com
Dimensions (mm)
VEC_GL (Compulsory accessory)
3610
3170
2350
2590
2270
1680
621
545
404
14,8
10
6
613
529
371
2
37
20
8
0,3
53
50
43
44,5
41,5
34,5
1,48
3/4"G
6,1V
5,1V
3,4V
VEC20GL
VEC30GL
VEC40GL
54I
4282
4154
2995
2909
2437
1785
737
714
515
30
28
18
613
529
371
2
37
20
8
0,3
53
50
43
44,5
41,5
34,5
1,48
3/4"G
6,1V
5,1V
3,4V
Ø262
B
E
595
C
D
15
A
A
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.
895 1195
Dimensions VEC_I + VEC_GL (maximum dimensions)
Mod.
Height
Widht
Depth
Weight (VEC_I)
Weight (VEC_GL)
VEC_I
20/24
VEC
20GL
(A) mm
(B) mm
(C) mm kg kg
283
595
595
15,5
3,7
30/34
30GL
283
895
595
20,6
5,7
Dimensions VEC_I + VEC_GL (Dimensions for installation)
40/44
40GL
283
1195
595
24,7
7
Mod.
Height
Widht
Depth
VEC_I
20/24
VEC
20GL
(A) mm 283
(D) mm
(E) mm
574
574
30/34
30GL
283
574
874
40/44
40GL
283
574
1174
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577 www.aermec.com
50/54
40GL
283
1195
595
24,7
7
50/54
40GL
283
574
174
59
FCL
Cassette type fancoil
Ceiling and false ceiling installation, cooling power from 1900 up to 11000W
Models:
FCL 32 , FCL36 , FCL42 , FCL62 - FCL72
FCL 34 , FCL38 , FCL44 , FCL64
Models:
FCL 82 , FCL102 , FCL122
FCL 84 , FCL104 , FCL124
FCL with accessory FCLMC
Aermec
participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.
com
GLL10 - GLL10M - GLL10R - GLL10N
White: RAL 9010
GLL20 - GLL20R - GLL20N
White: RAL 9010
FCLMC
White: RAL 9010
Remote Control included for GLL10M
GLL10R - GLL20R
• 4 CONFIGURATIONS ON ONE CASSETTE-TYPE FAN COIL:
- WITH MOTORISED LOUVERS THAT CAN BE ORIENTED VIA THE REMOTE CONTROL
(GLL10M ONLY)
- WITH LOUVERS THAT CAN BE ORIENTED MANUALLY, REMOTE CONTROL
- WITH MANUALLY ADJUSTABLE FINS, VMF SYSTEM ELECTRONIC THERMOSTAT,
WALL-MOUNTED CONTROL PANEL (VMF-E4), COMPLETE INTEGRATION WITH THE
VMF SYSTEM (ONLY WITH GLL10N AND GLL20N)
• STANDARD INTERNAL 3-WAY VALVE, WITH FAST CONNECTION ACTUATOR AND
VISUAL POSITION SIGNALLING
• VERSION WITH 2-WAY VALVE FOR VARIABLE WATER FLOW RATE SYSTEMS
• VERSION WITHOUT VALVES
• HEAT EXCHANGE COIL WITH SHAPED PROFILE AND ENHANCED SURFACE
• FAN PURPOSELY DESIGNED FOR LOW SOUND EMISSIONS
• VERSIONS FOR 2-PIPE AND 4-PIPE SYSTEMS
• ALSO AVAILABLE WITH ELECTRIC HEATER FOR HEATING
Features
• 8 sizes for 2-pipe versions:
FCL 32-36-42-62-72-82-102-122
• 7 sizes for 4-pipe versions:
FCL 34-38-44-64-84-104-124
• Standard preparation with standard internal three-way valve, with fast connection actuator and position visual signalling.
• FCL_V2 preparation (available upon request), with internal two-way valve, suitable for variable water flow rate systems.
• FCL_VL preparation (available upon request), without internal valve.
• 3 configurations on one cassette-type fan coil:
- louvers that can be oriented by means of a remote control and electronic control if coupled with the accessory GLL10M;
- with remote control, louvers that can be oriented manually and by means of electronic control if coupled with the accessory
GLL10R or GLL20R;
- with louvers that can be oriented manually if coupled with the accessory GLL10 or
GLL20, also requires a wired control panel
(accessory).
• High design aesthetics.
• Grille dimensions perfectly integrable in stand a r d s u s p e n d e d c e i l i n g p a n e l s o f
600x600mm and 840x840mm for the most powerful units.
• Fan designed for low sound emissions.
• 3-speed and 4-speed mixed flow (axial + centrifugal) fan unit for larger sizes (FCL
42-44-62-64-72-82-84-102-104-122-124), in order to select the 3 speeds that best meet delivered power and quiet operation requirements.
• The load-bearing structure, reinforced with a galvanised steel side band, contains insulation elements in expanded polystyrene obtained from injection moulding for purposes of noise reduction and air routing (FCL 42-44-
62-72-64).
• Structure made entirely of galvanised steel, containing insulation elements in closed cell expanded polystyrene and externally covered with anti-condensate felt (FCL 82-84-102-
104-122-124).
• Condensation drip tray in one piece, with V0 self-extinguishing level and overmoulding to insulation in expanded polystyrene with flame retardant additive.
• Heat exchanger with shaped profile to increase the exchange surface, and easily accessible drain valves.
• Continuous fan operation to prevent stratification of room air.
• Possibility of direct release of external air regardless of indoor unit ventilation.
• Possibility to control the climate of adjacent rooms as well. The versions FCL 82-84-102-
104-122-124 allow 3-direction delivery.
• Air filter easily removed and cleaned, selfsupporting structure, characterised by a high efficiency and low pressure drops, with class-
V0 fire resistance (UL 94).
• Electrostatically pre-charged air filter regenerated with fire resistance class 2 (UL 900),
(FEL 10 accessory for GLL10, GLL10R,
GLL10M).
• Full compliance with safety regulations.
• Easy installation and maintenance.
60
Accessories
Compulsary GLL accessories,
essential for unit operation:
• GLL10M (600x600)
Delivery grille with adjustable louvers by means of a remote control and air intake, supplied with an infrared receiver with emergency operation switch.
White RAL 9010.
• GLL10R (600x600)
GLL20R (840x840)
Delivery grille with louvers manually adjustable and air intake. With remote control, supplied with an infrared receiver with emergency operation switch. White RAL 9010.
• GLL10 (600x600)
GLL20 (840x840)
Delivery grille with louvers manually adjustable and air intake. Combined with wallmounted control panel. White RAL 9010.
• GLL10N (600x600)
GLL20N (840x840)
Delivery grille with Manually adjustable fins and air intake, with "VMF System" advanced electronic thermostat. Individual units, or network master also requires a wired control panel (VMF-E4 compulsory accessory). White
RAL 9010.
• Control panels and VMF System: the characteristics are described on the appropriate card.
Accessories:
• FCLMC10
FCLMC20
is a perimeter case in galvanised and painted sheet steel, which is used when the fan coil is installed outside the suspended ceiling. It is used for aesthetics and protection, therefore the technical features of the FCL and FCLI remain unvaried.
• FEL10 : kit n°5 electrostatically pre-charged air filter, with fire resistance class 2 (UL 900).
• KFL : Delivery flange, allowing the air to be directed to an adjacent room.
• KFL20 (***) : delivery flange, allowing the air to be directed to an adjacent room. Up to three KFL20 can be assembled on a single unit.
• KFLD : suction flange, allows to introduce external air directly into the room without mixing.
• KFLD20 (***) : suction flange, allows to introduce external air directly into the room without mixing. Up to two KFL20D can be assembled on a single unit.
• RXLE - RXLE20 : electric heater for heating, can be installed on the single-fan FCL units.
Requires GLL-M or GLL-R.
• SIT 3-5 : Thermostat Interface Cards. They allow the creation of a network of fan coils
(max. 6) commanded by a central control panel (selector or thermostat).
SIT3 : commands the 3 fan speeds and must be installed on each fan coil of the network; receives the commands from the selector or the SIT5 card.
SIT5: commands the 3 fan speeds and up to 2 valves (four pipes systems); transmits the thermostat commands to the network of fan coils fitted with SIT3.
• SW3 : Minimum water temperature probe, to be used with electronic PXAE thermostats.
• SW4 : Minimum water temperature probe, to be used with the units fitted with a grille with remote control. Conpulsury with GLL_M,
GLL_R, GLL_N
• SWA : External SWA probe accessory for
FMT21 panels. Detects the ambient air temperature if connected to the connector (A); the probe in the panel will be automatically disabled. Detects the temperature of the water in the system, for ventilation consent, if connected to the connector (W) (Length L = 6m)
• VHL1 - VHL20 : motor-driven three-way valve for the heating battery in 4-pipe systems.
Obligatory accessory in 4-pipe systems.
• VHL2 - VHL22 : motor-driven two-way valve for the heating battery in 4-pipe systems.
Obligatory accessory in 4-pipe systems with variable flow rates.
(2)
(2)
(1)
(1)
(3)
(1)
(3)
(1)
(1)
(1)
(1)
(1)
(3)
(3)
(3)
(3)
(3)
(3)(4)
(3)
(3)
(3)
(5)
•
•
•
•
•
•
•
•
•
-
-
-
-
•
•
•
•
-
•
•
-
•
-
•
-
-
-
•
32
•
•
•
•
-
SW3
SW4
SWA
VHL1
VHL20
VHL2
VHL22
SIT 3
SIT 5
FMT10
FMT21
PX
PX2- PX2C6
PXAE
TPF
WMT10
VMF-E4 / E4D
Mod. FCL
GLL10
GLL10M
GLL10R
GLL10N
GLL20
GLL20R
GLL20N
FCLMC10
FCLMC20
FEL10
KFL
KFL20
KFLD
KFLD20
RXLE
RXLE20
•
•
•
•
•
•
•
•
•
•
-
•
-
•
•
•
-
-
•
•
-
•
-
•
-
-
-
•
64
•
•
•
•
-
•
•
•
•
•
•
•
•
•
-
-
-
-
•
•
•
•
-
•
•
-
•
-
•
-
-
-
•
62
•
•
•
•
-
•
•
•
•
•
•
•
•
•
•
-
•
-
•
•
•
-
-
•
•
-
•
-
•
-
-
-
•
44
•
•
•
•
-
•
•
•
•
•
•
•
•
•
-
-
-
-
•
•
•
•
-
•
•
-
•
-
•
-
-
-
•
42
•
•
•
•
-
•
•
•
•
•
•
•
•
•
•
-
•
-
•
•
•
-
-
•
•
-
•
-
•
-
-
-
•
38
•
•
•
•
-
•
•
•
•
•
•
•
•
•
-
-
-
-
•
•
•
•
-
•
•
-
•
-
•
-
-
-
•
36
•
•
•
•
-
•
•
•
•
•
•
•
•
•
•
-
•
-
•
•
•
-
-
•
•
-
•
-
•
-
-
-
•
34
•
•
•
•
-
(1) Compulsory with GLL_M, GLL_R, GLL_N
(2) A maximum of three KFL20 / KFL20D can be assembled on a single unit
(3) Accessories that can only be used in combination with GLL10 and GLL20 grilles
.
(4) PX2C6 = Multiple package of n°6 “PX2” control panels
(5) Accessories that can only be used in combination with the GLL10N and GLL20N grilles for individual units or network master
•
•
•
•
•
•
•
•
•
-
-
-
-
•
•
•
•
-
•
•
-
•
-
•
-
-
-
•
72
•
•
•
•
-
•
•
•
•
•
•
•
•
•
-
-
-
-
•
•
•
-
•
•
-
•
-
•
-
•
•
•
-
82
-
-
-
-
•
•
•
•
•
•
•
•
•
•
-
•
-
•
•
•
•
•
-
•
-
•
-
•
•
•
-
-
84
-
-
-
-
•
•
•
•
•
•
•
•
•
•
-
-
-
-
•
•
•
-
•
•
-
•
-
•
-
•
•
•
-
102
-
-
-
-
•
•
•
•
•
•
•
•
•
•
-
•
-
•
•
•
•
•
-
•
-
•
-
•
•
•
-
-
104
-
-
-
-
•
•
•
•
•
•
•
•
•
•
-
-
-
-
•
•
•
-
•
•
-
•
-
•
-
•
•
•
-
122
-
-
-
-
•
•
•
•
•
•
•
•
•
•
-
•
-
•
•
•
•
•
-
•
-
•
-
•
•
•
-
-
124
-
-
-
-
•
61
Technical data
Mod.
Heating capacity (70°C)
(1)
(1)
(1)
(2)
(2)
(2)
(2)
(2)
(1)
(1)
(1)
(1)
(1)
FCL
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1) W kPa kPa kPa
W
W
W l/h l/h
W
W l/h l/h l/h
Vel.
32
H
3995
M 2946
L
2221
34
-
-
36
6270
4503
38
-
-
42
7335
4473
44
-
-
62
10487
6373
64
-
-
72 82
11321 11877
7571 8118
84
-
-
102
17727
11714
104
-
-
122
21747
14729
124
-
-
Water flow rate
Pressure drop
Heating capacity (50°C)
Water flow rate
Pressure drop
Power supply
(2)
(2)
(2)
(2) l/h kPa kPa kPa
M
L
L
H
H
M
L
H
M
L
H
H
M
350
258
195
10
6
4
2380
M 1760
L
1330
327
253
200
9
6
4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3423
550
395
300
19
10
6
3750
2690
2050
516
387
308
14
8
5
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3319
643
392
291
24
10
6
4400
2690
2000
679
437
337
23
10
6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
5192
920
559
455
42
17
12
6250
3830
3100
857
552
458
32
15
10
V1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
V1
6143 5875
993
664
539
42
20
14
1042
712
515
26
13
7
6750 7100
230V/1/50Hz
4490 4850
3650 3500
939
576
482
38
16
11
V1
1032
697
482
23
11
6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
8295
1555
1028
728
25
12
6
10600
7000
4950
1548
1015
697
25
12
6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
10531
1908
1292
924
42
21
11
13000
8800
6300
1892
1290
922
34
17
9
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
(3) W H 2600 -
Heating capacity (70°C) 2190 -
2600
2190 (3)
(3)
(3)
W
W l/h
M
L
H
-
1950
228 -
1950
228
Water flow rate
Pressure drop
(3)
(3)
(3)
(3) l/h l/h kPa kPa
M
L
H
M
-
-
-
-
192
171
11
8
-
-
-
-
192
171
11
8
-
-
-
-
-
-
-
2730
2290
1960
240
201
172
12
8
-
-
-
-
-
-
-
3570
2810
2480
313
247
218
22
15
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
8500
6400
5300
746
561
465
14
9
-
-
-
-
-
-
-
10000
7300
5900
877
640
518
19
11
-
-
-
-
-
-
-
12500
9300
7050
1097
816
618
29
17
(3) kPa L 6 6 6 12 6 7 10
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
(4) W H 1900 1900 3000 2770 3950 3000 4980 4610 5460 6000 6000 9000 7200 11000 8800
Total cooling capacity (4)
(4)
(4)
W
W
W
L
H
M 1470 1470 2250 2080 2540 2340 3210 2970 3350 4050 4050 5900 4920 7500 6220
1160 1160 1790 1650 1960 1810 2660 2460 2800 2800 2800 4050 3500 5360 4570
1520 1520 2400 2240 3160 2180 3810 3530 4100 4200 4200 6660 5300 8470 6770
Sensible cooling capacity
Water flow rate
Pressure drop
Air flow rate
Fans
Absorbed power
Max. input current
Sound power level
Sound pressure level
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
W
W l/h l/h l/h kPa kPa kPa m m m type n°
230V W
230V W
230V W
(6)
(6)
(6)
3
3
3
/h
/h
/h
230V A
(5) dB(A)
(5)
(5) dB(A) dB(A) dB(A) dB(A) dB(A)
H
M
L
H
M
L
M
L
L
H
H
M
M
1250 1250 1780 1660 1820 1680 2270 2100 2350 2770 2770 4300 3530 5730 4670
L 990 990 1390 1300 1380 1270 1860 1720 1890 1900 1900 2940 2480 4040 3370
327 327 516 476 679 516 857 793 939 1032 1032 1548 1238 1892 1514
253 253 387 358 437 402 552 511 576 697 697 1015 846 1290 1070
200 200 308 284 337 311 458 423 482 482 482 697 602 922 786
10
7
4
600
10
7
4
600
15
9
6
600
13
8
5
600
25
11
7
700
15
10
6
700
36
16
12
880
35
16
11
880
43
18
13
900
25
12
6
1100
25
12
6
1100
28
13
7
1350
26
13
7
1350
38
19
10
1750
38
22
10
1750
410
300
410
300
410
300
410
300
360
260
360
260
500
380
500
380
520
400
680
460
680
460
830
560
830
560
1100
750
1100
750
H
M
L
H
M
L
1
45
31
21
0,22
46
38
35
37
29
26
1
45
31
21
0,22
46
38
35
37
29
26
1
45
31
21
0,22
46
38
35
37
29
26
1
45
31
21
0,22
46
38
35
37
29
26
1
75
32
22
0,33
53
38
35
44
29
26
1
47
32
22
0,33
46
38
35
37
29
26
1
83
37
26
0,37
61
47
41
52
38
32 centrifugal
1
101
45
32
0,45
61
47
41
52
38
32
1
110
58
50
0,52
60
49
43
51
40
34
1
150
80
45
0,7
50
43
39
41
34
30
1
150
80
45
0,7
50
43
39
41
34
30
1
155
80
50
0,7
54
45
40
45
36
31
1
155
80
50
0,7
54
45
40
45
36
31
1
175
105
55
0,75
60
50
44
51
41
35
1
175
105
55
0,75
60
50
46
51
41
37
Water content
Water content (additiona heat exchanger)
Coil connections
Coil connections (additiona heat exchanger)
ø
ø l l
1,2
-
3/4"
-
1,2
0,3
3/4"
1/2"
1,5
-
3/4"
-
1,5
0,5
3/4"
1/2"
1,5
-
3/4"
-
1,5
0,5
3/4"
1/2"
2,1
-
3/4"
-
2,1
0,6
3/4"
1/2"
2,1
-
3/4"
-
3,0
-
3/4"
-
3,0
1,5
3/4"
1/2"
4,5
-
3/4"
-
4,5
1,5
3/4"
1/2"
4,5
-
3/4"
-
4,5
1,5
3/4"
1/2"
Speed connected
H
M
V3
V2
V3
V2
V3
V2
V3
V2
V4
V2
V4
V2
V4
V2
V4
V2
V4
V2
V4
V2
V4
V2
V4
V2
V4
V2
V4
V2
V4
V2
L V1 V1 V1 V1 V1 V1 V1 V1 V1 V1 V1 V1
H max. speed; M med. speed; L min. speed
Heating mode
2 pipes system configuration
(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode
4 pipes system configuration (with additional heat exchanger) (EUROVENT)
(3)Room air temperature 20°C b.s.; Inlet water temperature 70°C; ΔT water 10°C
Cooling mode (EUROVENT)
(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(6) Sound pressure level (A-weighted) measured in the room with volume V=100m
3
, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com
62
Dimensions (mm)
FCL 32 - 34 - 36 - 38 - 42 - 44 - 62 - 64 - 72
FCL 32 V2 - 34 V2 - 36 V2 - 38 V2 - 42 V2 - 44 V2 - 62 V2 - 64 V2 - 72 V2
FCL 32 VL - 34 VL - 36 VL - 38 VL - 42 VL - 44 VL - 62 VL - 64 VL - 72 VL
Mod. FCL
Weight
Mod. FCL
Wheigt
Mod. FCL
Weight kg kg
32
20,5
32 V2
20,5
32 VL
20
34
21
34 V2
21
34 VL
20,5 kg
FCL 82 - 84 - 102 - 104 - 122 - 124
FCL 82 V2 - 84 V2 - 102 V2 - 104 V2 - 122 V2 - 124 V2
FCL 82 VL - 84 VL - 102 VL - 104 VL - 122 VL - 124 VL
36
20,5
36 V2
20,5
36 VL
20
38
21
38 V2
21
38 VL
20,5
42
20,5
42 V2
20,5
42 VL
20
44
21
44 V2
21
44 VL
20,5
62
22
62 V2
21
62 VL
21,5
64
22,5
64 V2
22,5
64 VL
22
72
22,5
72 V2
22,5
72 VL
22
GLL20N
GLL20N
Mod. FCL
Weight
Mod. FCL
Weight kg
82
35
82 V2
35
84
36
84 V2
36
102
36
102 V2
36 kg
Mod. FCL
Weight kg
All specifications are subject to change without prior notice.
Although every effort has been made to ensure accuracy, Aermec does not assume responsibility or liability for eventual errors or omissions
32 VL
34
34 VL
35
102 VL
35
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577 www.aermec.com
104
36
104 V2
36
104 VL
35
122
36
122 V2
36
122 VL
35
124
36
124 V2
36
124 VL
35
63
FCLI
Cassette-type fancoils with Brushless Inverter motor (EC)
Continuous 0-100% air flow rate regulation
Ceiling and false ceiling installation, cooling power from 1900 up to 11000W
Models:
FCLI32 , FCLI42 , FCLI62
FCLI34 , FCLI44 , FCLI64
Models:
FCLI82 , FCLI122 , FCLI124
FCLI with accessory FCLMC
Aermec
participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com
GLLI10 - GLLI10N
White: RAL 9010
GLLI20 - GLLI20N
White: RAL 9010
FCLMC
White: RAL 9010
• ENERGY SAVINGS OF 50% COMPARED WITH A FAN
COIL WITH TRADITIONAL 3-SPEED MOTOR
• VERY QUIET OPERATION
• TOTAL COMFORT: REDUCED TEMPERATURE AND
•
HUMIDITY VARIATIONS IN THE AIR-CONDITIONED
ROOMS
STANDARD INTERNAL THREE-WAY VALVE, WITH FAST
CONNECTION ACTUATOR AND POSITION VISUAL
•
•
SIGNALLING
VERSION WITH 2-WAY VALVE FOR VARIABLE WATER
FLOW RATE SYSTEMS
VERSION WITHOUT VALVES
Features
• Fan unit with Brushless motor (Continuous
0-100% speed variation);
• 5 sizes for 2-pipe versions:
FCLI 32-42-62-82-122
• 4 sizes for 4-pipe versions:
FCLI 34-44-64-124
• Standard preparation with standard internal three-way valve, with fast connection actuator and visual signalling of the position
• FCLI_V2 preparation (available upon request), with internal two-way valve, suitable for variable water flow rate systems
• FCLI_VL preparation (available upon request), without internal valve
• Requires matching with the obligatory accessories, grill and control panel, necessary for the operation
• High design aesthetics
• Grille dimensions that can be perfectly incorporated into standard suspended ceiling panel sizes (600x600 mm) and (840X840) for more powerful units.
• Fan for low sound emissions
• EUROVENT certification
• The load-bearing structure, reinforced with a galvanised steel side band, contains insulation elements in expanded polystyrene obtained from injection moulding for purposes of noise reduction and air routing
• The condensation drip tray is in one piece, with V0 self-extinguishing level and joined by means of over-moulding technology to the insulation in expanded polystyrene with flame retardant additive
• Heat exchanger with shaped profile to increase the exchange surface, and easily accessible drain valves
• Possibility of direct release of external air regardless of indoor unit ventilation
• Air filter easily removed and cleaned, selfsupporting structure, characterised by a high efficiency and low pressure drops, with a fire resistance class V0 (UL 94)
• Electrostatically pre-charged air filter regenerated with fire resistance class 2 (UL 900), (FEL
10 accessory)
• Full compliance with the accident prevention standards
• Ease of installation and maintenance
64
Accessories
Obligatory accessories, essential for unit operation:
• GLLI10 (600x600)
GLLI20 (840x840)
Delivery grille with louvers manually adjustable and air intake. Combined with wallmounted control panel. White RAL 9010.
• WMT20 : Control panel with electronic thermostat and LCD monitor. Wall mounting.
• SWI : Water temperature probe for WMT20 control panels. Cable length L = 2m.
• GLLI10N (600x600)
GLLI20N (840x840)
Delivery grille without water probe, with
Manually adjustable fins and air intake, with
"VMF System" advanced electronic thermostat.
Individual units, or network master also requires a wired control panel (VMF-E4 compulsory accessory). White RAL 9010.
• VMF-E4 : Control panel “VMF System” with electronic thermostat and LCD monitor. Wallmounting
• SW4 : Water temperature probe for the control of maximum / minimum temperature (2-pipe system) or for the control of minimum temperature in the heating coil (4-pipe system)
• VMF-SW1 : Water temperature probe for the control of maximum temperature in the cooling coil (4-pipe system)
• Control panels and VMF System: the characteristics are described on the appropriate card.
Accessories:
• FCLMC10
FCLMC20 : is a perimeter case in galvanised and painted sheet steel, which is used when the fan coil is installed outside the suspended ceiling. It is used for aesthetics and protection, therefore the technical features of the
FCL and FCLI remain unvaried. FCLMC20 requires the combination with the
FCLMC20IK accessory.
• FCLMC20IK : Installation kit for Controller
Inverter, compulsory for units with FCLM20.
• FEL10 : electrostatically pre-charged air filter, regenerated with fire resistance class 2 (UL 900).
• KFL10
KFL20 : Delivery flange, allowing the air to be directed to an adjacent room.
• KFLD
KFLD20 : suction flange, allows to introduce external air directly into the room without mixing.
• VHL1 : motor-driven three-way valve for the heating battery in 4-pipe systems. Obligatory accessory in the 4-pipe systems.
• VHL2 : motor-driven two-way valve for the heating battery in 4-pipe systems. Obligatory accessory for 4-pipe systems with variable flow rates.
Mod. FCLI
GLLI10
GLLI20
WMT20
GLLI10N
GLLI20N
VMF-E4 *
FCLMC10
FCLMC20 **
FCLMC20IK **
FEL10
KFL
KFL20
KFLD
KFLD20
VHL1
VHL2
SWI
SW4 *
VMF-SW1 *
32
•
•
•
•
•
•
•
•
•
•
34
•
•
•
•
•
•
•
•
•
•
•
•
•
42
•
•
•
•
•
•
•
•
•
•
Compatibility of accessories
44
•
•
•
•
•
•
•
•
•
•
•
•
•
* Accessory for GLLI_N
** FCLMC20 requires the combination with the FCLMC20IK accessory
62
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
64
•
•
•
•
•
•
•
•
•
•
•
•
•
82
•
•
•
•
•
•
•
•
•
•
122
•
•
•
•
•
•
124
•
•
•
•
•
•
•
•
•
65
Technical data
Mod.
FCLI Vel.
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1) W H
Heating capacity (70°C)
Water flow rate
Pressure drop
Heating capacity (50°C)
Water flow rate
Pressure drop
(1)
(1)
(1)
(1)
(2)
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2) l/h kPa kPa kPa
W
W
W l/h l/h
W
W l/h l/h l/h kPa kPa kPa
M
L
H
L
H
M
L
H
M
M
L
H
M
M
L
L
H
32 34
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1760
1330
327
253
200
9
6
4
3995
2946
2221
350
258
195
10
6
4
2380
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
(3) W H 2600
Heating capacity (70°C) (3) W M 2190
Water flow rate
(3)
(3)
(3)
W l/h l/h
L
H
M -
-
1950
228
192
Pressure drop
(3)
(3)
(3) l/h kPa kPa
L
H
M
(3) kPa L
COOLING PERFORMANCE (2 and 4 PIPE CONFIGURATIONS)
Total cooling capacity
(4)
(4)
W
W
H
M
-
-
-
171
11
8
6
Sensible cooling capacity
Water flow rate
(4)
(4)
(4)
(4)
(4)
(4)
W
W
W
W l/h l/h
L
H
M
L
H
M
1900
1470
1160
1520
1250
990
327
253
1900
1470
1160
1520
1250
990
327
253
Pressure drop
Air flow rate
Fans
Absorbed power
Max. input current
Sound power level
Sound pressure level
Water content
Water content (additiona heat exchanger)
Coil connections
Coil connections (additiona heat exchanger)
Percentage of work than the signal configuration
(4)
(4)
(4)
(4)
(5)
(5)
(5)
(6)
(6)
(6) l/h kPa kPa kPa m 3 /h m 3 /h m
3
/h type
ø
ø
% l l dB(A) dB(A) n°
W
W
W
(A) dB(A) dB(A) dB(A) dB(A)
%
%
M
L
L
H
L
H
M
H
M
L
H
M
L
H
M
L
H
M
L
29
26
1,2
-
3/4"
-
90
46
38
35
37
1
18
13
10
0,28
200
10
7
4
600
410
300
62
42
29
26
1,2
0,3
3/4"
1/2"
90
46
38
35
37
1
18
13
10
0,28
200
10
7
4
600
410
300
62
42
Power supply
42
4850
3500
1032
697
482
23
11
6
11877
8118
5875
1042
712
515
26
13
7
7100
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3830
3100
857
552
458
32
15
10
10487
6373
5192
920
559
455
42
17
12
6250
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2690
2000
679
437
337
23
10
6
7335
4473
3319
643
392
291
24
10
6
4400
29
26
1,5
-
3/4"
-
90
53
38
35
44
1
55
16
12
0,43
46
34
337
25
11
7
700
360
260
3950
2540
1960
3160
1820
1380
679
437
-
-
-
-
-
-
-
-
-
44
29
26
1,5
0,5
3/4"
1/2"
90
46
38
35
37
1
55
16
12
0,43
46
34
311
15
10
6
700
360
260
3000
2340
1810
2180
1680
1270
516
402
2730
2290
1960
240
201
172
12
8
6
62
38
32
2,1
-
3/4"
-
90
1
61
20
14
0,47
61
47
41
52
458
36
16
12
880
500
380 centrifugal
4980
3210
2660
3810
2270
1860
857
552
52
40
230V/1/50Hz
-
-
-
-
-
-
-
-
-
64
38
32
2,1
0,6
3/4"
1/2"
90
1
61
20
14
0,47
61
47
41
52
52
40
423
35
16
11
880
500
380
4610
2970
2460
3530
2100
1720
793
511
3570
2810
2480
313
247
218
22
15
12
82
34
30
3,0
-
3/4"
-
90
1
33
14
9
0,71
50
43
39
41
54
38
482
25
12
6
1100
680
460
6000
4050
2800
4200
2770
1900
1032
697
-
-
-
-
-
-
-
-
-
122
H max. speed; M med. speed; L min. speed
Heating mode
2 pipes system configuration
(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C;
ΔT water 10°C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode
4 pipes system configuration (with additional heat exchanger) (EUROVENT)
(3)Room air temperature 20°C b.s.; Inlet water temperature 70°C;
ΔT water 10°C
Cooling mode (EUROVENT)
(4) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C
(5) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(6) Sound pressure level (A-weighted) measured in the room with volume V=100m 3 , reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com
41
35
4,5
-
3/4"
-
90
1
135
33
16
0,80
60
50
44
51
58
38
922
38
19
10
1750
1100
750
11000
7500
5360
8470
5730
4040
1892
1290
-
-
-
-
-
-
-
-
-
8800
6300
1892
1290
922
34
17
9
21747
14729
10531
1908
1292
924
42
21
11
13000
66
124
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
786
38
22
10
1750
1100
750
8800
6220
4570
6770
4670
3370
1514
1070
12500
9300
7050
1097
816
618
29
17
10
41
37
4,5
1,5
3/4"
1/2"
90
1
135
33
16
0,80
60
50
46
51
58
38
Dimensions (mm)
FCLI 32 - 34 - 42 - 44 - 62 - 64
FCLI 32 V2 - 34 V2 - 42 V2 - 44 V2 - 62 V2 - 64 V2
FCLI 32 VL - 34 VL - 42 VL - 44 VL - 62 VL - 64 VL
GLLI 10
GLLI 10N
Mod. FCLI
Weight kg
Mod. FCLI
Weight
Mod. FCLI
Weight kg kg
FCLI 82 - 122 - 124
FCLI 82 V2 - 122 V2 - 124 V2
FCLI 82 VL - 122 VL - 124 VL
32
20,5
32 V2
20,5
32 VL
20
34
21
34 V2
21
34 VL
20,5
42
20,5
42 V2
20,5
42 VL
20
GLLI 10
GLLI 10N
44
21
44 V2
21
44 VL
20,5
62
22
62 V2
21
62 VL
21,5
64
22,5
64 V2
22,5
64 VL
22
GLLI20
GLLI 20N
Mod. FCLI
Weight
Mod. FCLI
Weight kg
82
35
82 V2
35 kg
Mod. FCLI
Weight kg
32 VL
34
All specifications are subject to change without prior notice.
Although every effort has been made to ensure accuracy, Aermec does not assume responsibility or liability for eventual errors or omissions
122
36
122 V2
36
124
36
124 V2
36
122 VL
35
124 VL
35
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Telephone 0442633111 - Telefax 044293577 www.aermec.com
FCLI
67
FCW
Fan coils
Wall-mount installation
Aermec
is participating in the EUROVENT Program: FCH
The related products can be found at the website www.eurovent-certification.com
• VERSIONS WITH INTERNAL 2- OR 3-WAY VALVE
• QUICK AND EASY INSTALLATION
• COMPACT DIMENSIONS
Features
By appropriately combining the options available, it is possible to select the model that satisfies the specific system requirements.
Sale code description:
Code
FCW
Size
21-31-41
Valve
2V (with internal 2-way valve)
3V (with internal 3-way valve)
VL (without valve)
Microprocessor control
(Empty) with control board
N without control board
FCW is a fan coil model for wall-mount installations, whose elegance and reduced dimensions make it aesthetically pleasing; this terminal is thus suitable for applications in residential or light commercial sectors.
The product is configurable and available with or without (2- or 3-way) valve, as well as with or without control board, which ensures c o m p a t i b i l i t y w i t h v a r i o u s s y s t e m requirements.
Fan coils without control board must be necessarily combined with an external control device.
• Cream Colour
• Display on the front panel
• Three-speed cross flow fan
• Maximum silence
• Aesthetically styled with flat panel
• Air flow louvered fins with horizontal adjustment facility
• Motorised deflector louvers that can be activated by remote control TLW2 and remote panel PFW2 for vertical orientation of the outlet air with 4 fixed positions and continuous oscillation
• Timer for programming switch-off or switchon (TLW2 and PFW2)
Accessories
• Program for operation in automatic, cooling, heating, ventilation and air ionising mode
(TLW2 and PFW2);
• Night time Well-being Program (TLW2)
• Automatic season change (TLW2 and PFW2)
• Automatic re-start after power cut (TLW2 and
PFW2)
• Easy installation and maintenance.
• Air filter with easy extraction and cleaning
• Full compliance with accident-prevention standards.
For models with control board installed
FCW_2V, 3V, VL it is mandatory to select among the user interfaces designed for the
FCW series (TLW2 or PFW2)
For models without control board installed
FCW_2VN, 3VN, VLN a user interface must be mounted outside the fan coil, using either a visible or a recessed wall-mount installation.
To make the selection, please refer to the
"control panels" or "VMF system" sheets, where you will find comprehensive information on this topic.
• Remote control TLW2
(mandatory accessory for versions with controller FCW_2V, FCW_3V, FCW_VL):
This accessory is required for operating the fan coil as an alternative to the wired remote control panel PFW2; it is not possible to use two remote control models at the same time.
Infrared remote control with liquid crystal display for controlling all unit functions.
The remote control is delivered separately from the fan coil; with a single remote control it is possible to control more than one fan coil.
The remote control is equipped with a support that allows you to hang it on the wall, from which it can be operated without having to be removed.
• Wired control panel PFW2
(mandatory accessory for versions with controller FCW_2V, FCW_3V, FCW_VL):
This accessory is required for operating the fan coil as an alternative to the wired remote control panel TLW2; it is not possible to use two remote control models at the same time.
The PFW2 panel can control only one fan coil.
The panel must be wall-mounted and connected to the fan coil using the 7.5-metre long cable provided.
68
Technical data
Mod.
FCW
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1) W
Thermal power (70°C)
Water flow rate
(1)
(1)
(1)
(1)
W
W l/h l/h
Pressure drops
Thermal power (50°C)
Water flow rate
Pressure drops
(1)
(2)
(2)
(2)
(1)
(1)
(1)
(2)
(2)
(2)
(2)
(2)
(2) l/h kPa kPa kPa l/h kPa kPa kPa
W
W
W l/h l/h
COOLING PERFORMANCE
Total cooling capacity
Sensitive cooling capacity
Water flow rate
Water pressure drops
Air flow rate fans
Input power
Maximum input current
Sound power
Sound Pressure
Water content
Coil connections
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(4)
(4)
(4)
(5)
(5)
(5) l/h l/h l/h kPa kPa kPa m
3
/h m 3 /h m
3
/h type n°
W
W
W
(A)
W
W
W
W
W
W dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) l
ø Gas (F)
Speed
H
M
L
H
M
L
H
M
L
M
L
L
H
H
M
M
L
L
H
H
M
L
H
M
H
M
L
M
L
L
H
H
M
L
H
M
H
M
L
H
M
L
212V
24
2400
1800
1400
327
249
189
21
13
8
4031
3020
2353
354
265
206
9
14
53
48
42
44.5
39.5
34.0
1
27
24
23
0.13
327
249
189
23
14
9
380
330
270
1900
1450
1100
1550
1200
920
213V
24
2400
1800
1400
327
249
189
21
13
8
4031
3020
2353
354
265
206
9
14
53
48
42
44.5
39.5
34.0
1
27
24
23
0.13
327
249
189
23
14
9
380
330
270
1900
1450
1100
1550
1200
920
21VL
4
2560
2180
1700
353
299
236
8
6
4
4297
3660
2852
377
321
250
9
6
53
48
42
44.5
39.5
34.0
1
27
24
23
0.13
353
299
236
9
7
5
389
340
280
2050
1740
1370
1730
1470
1160
312V
13.4
3000
2600
1940
413
358
267
26
20
12
5035
4363
3256
442
383
286
29.4
22.7
53
48
42
44.5
39.5
34.0
1
27
23
22
0.13
413
358
267
29
22
13
440
390
320
2400
2080
1550
1970
1680
1280
313V
13.4
3000
2600
1940
413
358
267
26
20
12
5035
4363
3256
442
383
286
29.4
22.7
2400
2080
1550
1970
1680
1280
413
358
267
29
22
13
440
390
320 tangential
1
27
23
22
0.13
53
48
42
44.5
39.5
34.0
31VL
8.6
3120
2690
2220
430
370
306
14
10
7
5245
4515
3734
460
396
328
15.9
12.1
53
48
42
44.5
39.5
34.0
1
27
23
22
0.13
430
370
306
15
11
8
446
400
330
2500
2150
1780
2040
1820
1510
412V
21
4750
4310
3750
654
593
516
28
24
18
7972
7234
6294
699
635
552
32
27
54
49
44
45.5
40.5
35.5
1
48
41
31
0.23
654
593
516
32
27
21
540
470
370
3800
3450
3000
2850
2500
2010
413V
21
4750
4310
3750
654
593
516
28
24
18
7972
7234
6294
699
635
552
32
27
54
49
44
45.5
40.5
35.5
1
48
41
31
0.23
654
593
516
32
27
21
540
470
370
3800
3450
3000
2850
2500
2010
41VL
Speeds connected
H
M
L
½” F
V3
V2
V1
½” F
V3
V2
V1
½” F
V3
V2
V1
½” F
V3
V2
V1
½” F
V3
V2
V1
230V/1/50Hz
½” F
V3
V2
V1
½” F
V3
V2
V1
½” F
V3
V2
V1
½” F
V3
V2
V1
Electric power supply
H maximum speed; M medium speed; L minimum speed
Heating
2-pipe system configuration
(1) Ambient air temperature 20°C d.b.; Inlet water temperature 70°C; DT water 10°C
2-pipe system configuration (EUROVENT)
(2) Ambient air temperature 20°C d.b.; Inlet water temperature 50°C; Water flow rate the same as in Cooling mode
Cooling (EUROVENT)
(3) Ambient air temperature 27°C d.b./19°C w.b.; Inlet water temperature 7°C; DT water 5°C
(4) Sound power based on the measurements carried out in accordance with Eurovent 8/2 standard
(5) Sound pressure level (A weighted) measured in environment with volume V=85m3 , reverberation time t=0.5s directivity factor Q=2; distance r=2.5m
Note: The speeds connected can differ from the factory standard configuration, for more information refer to the selection program and to the technical documentation available at www.aermec.com
54
49
44
45.5
40.5
35.5
1
48
41
31
0.23
702
643
528
26
21
15
684
602
476
4080
3740
3070
3470
3100
2590
16
5100
4670
3840
702
643
528
23
19
14
8560
7846
6444
751
688
565
26
22
Dimensional data (mm)
C
FCW
Height
Width
Depth
Weight
A
B
C kg
21
298
880
205
9
31
305
990
210
10
41
360
1172
220
19
B
A
TLW2 accessory
PFW2 accessory
Aermec reserves the right to make all the modifications deemed necessary for improving the product, including technical data.
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 039 0442633111 - Telefax +39 044293577 www.aermec.com
69
70
FHX
Fan coils
With germicidal lamp
Aermec
participate in the EUROVENT program: FCH the products are present on the site www.eurovent-certification.com
FHX-UVP
FHX-UVPO
FHX-UV
Cabinet RAL 9002 heatboard RAL 7044
• GERMICIDAL LAMP INCORPORATED
• ESSENTIAL IN ENVIRONMENTS THAT REQUIRE THE
HIGHEST LEVELS OF HYGIENE
• 3 ROW COIL
The FHX fan coil is fitted with an exclusive device for air sterilization, making it essential in environments that require the highest levels of hygiene, such as:
• hospitals
• dentists' surgeries
• doctors' and vets' surgeries
• analysis laboratories
• pharmaceutical companies
• waiting rooms
• beauty institutes
• homes
• offices
• public premises
Features
• Versions:
FHX-UV: universal free-standing or wall/ceiling mounting.
FHX-UVP: wall-mounted model without cabinet.
FHX-UVPO: wall-mounted model without cabinet, with boosted motor at 6/7 speeds (3 selectable).
• Compatible with VMF System.
• Exclusive air sterilization system with germicidal lamps. Efficiency of 99.999% in the deactivation of all microorganism Gram - and
Gram +
• 3 row coil.
• 3-speed ventilating unit.
• Full compliance with the accident prevention standards.
• Rounded line.
• Quiet operation.
• Low loss of charge in the heat exchange batteries.
• Electric motors with permanently inserted condensers.
• Ease of installation and maintenance.
• Air filter easy to remove and clean.
• Control made by a microprocessor thermostat supplied as an accessory:
- FHX-UVP and UVPO: requires external control panel.
- FHX-UV: The control panel may be fitted on board the unit or externally.
• FHX-UV: Metal protection cabinet with varnishing in anticorrosion polyester, colour
RAL9002.
• FHX-UV: The air delivery and suction louvers are made of plastic material, colour RAL7044
• Adjustable air delivery louver on version UV except models 62 and 82.
Accessories
• AMP20: kit for the wall mounting installation
• BC: Auxiliary condensate drip tray.
• GA: Intake louver with fixed slats.
• GAF: Intake louver with fixed slats and filter.
• GM: Delivery louver with adjustable slats.
• PA: Intake Plenum made of galvanized steel sheet, provided with Intake Connections for
Circular Section Ducts.
• PA-F: Intake plenum that allows to have the intake and the delivery on the same side, suitable for all the installations where it is requested to put the appliance outside the airconditioned rooms in order to reduce to the minimum the noise and facilitate the maintenance operations.
• PC: Rear cover panel. Conveniently covers exposed rear fancoil sections. The panel is required by current safety standards for units installed away from the room wall.
• PM: Delivery plenum in galvanized steel with external insulation, with plastic outlet connections for circular section ducting.
• RD: Delivery straight duct connection.
• RDA: Intake straight duct connection.
• RP: Delivery 90° duct connection.
• RPA: Intake 90° duct connection.
• SE: Manually operated fresh air intake louver.
SIT 3-5: Thermostat interface cards. They allow to set up a fancoils network (max. 10) commanded by a centralised panel (switch or thermostat).
SIT3: commands the three speeds of the fan and must be installed on each fancoil of the network; it receives the commands from the switch or from the SIT5 card.
SIT5: commands the 3 fan speeds and up to two valves (four-pipe systems); it sends the thermostat commands to the fancoils network.
• SW: Probe for the electronic thermostats which permits operation of the unit only with water above 35 °C.
• VCF: The SW3 probe must be combined to
this accessory.
Kit complete with copper connections and 3 way valves all or nothing type, to be powered by a 230 V ~ 50Hz, 24 V ~ 50Hz voltage supply.
Attention: The VCF valve and the drip tray
BC4 can be installed at the same time as the fan coil.
• VCFD: The SW3 probe must be combined to
this accessory.
Kit complete with copper connections and 2 way valves all or nothing type, to be powered by a 230 V ~ 50Hz, 24 V ~ 50Hz voltage supply.
Attention: The VCFD valve and the drip tray
BC4 can be installed at the same time as the fan coil.
• ZX: Feet for built-in installation.
Compulsory accessories to choose from
• PXAE: Electronic thermostat simplified controls with only 2 selectors for adjusting temperature and fan speed (3 speeds, manual or automatic control). Continuous or thermostated ventilation. Wall installation.
• PXAI: Electronic thermostat simplified controls with only 2 selectors for adjusting temperature and fan speed (3 speeds, manual or automatic control). Water temperature sensor included.
• Control panels and VMF System: the characteristics are described on the appropriate card.
AMP 20
4
BC
5
6
8
GA
GAF
62
22
32
9
22
32
42
GM
PA
42
62
22
32
42
62
22
32
PA
42
62
22F
32F
42F
62F
23
PC
PM
33
43
62
22
32
42
62
PXAE
PXAI
Accessories
(1)
(1)
(2)
(2)
Size (FHX)
22 32 42 50 62 82
• • • • •
•
•
•
•
•
•
•
•
• •
• •
• • • •
• •
•
•
• •
• •
•
•
• •
• •
•
•
• •
• •
•
•
• •
• •
•
•
• •
• •
•
•
• •
• •
•
•
• •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Versions
UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UV
UV
UV
UV
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UV-UVP-UVPO
UV
Accessories
RD
RDA
RP
RPA
SE
SIT3
SIT5
SW3
VCF
VCFD
ZX
2
3
124
224
324
7
8
41
42
43
4124
4224
4324
1
42
62
22
32
42
62
22
32
62
22
32
22
32
42
42
62
20X
30X
40X
80X
(3)
(3)
(3)
(3)
•
•
•
•
Size (FHX)
22 32 42 50 62 82
•
•
• •
• •
•
•
• •
• •
•
•
• •
• •
•
•
• •
• •
•
•
• •
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• • • •
• •
UVP-UVPO
UVP-UVPO
UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UV-UVP-UVPO
UVP-UVPO
UVP-UVPO
Versions
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
UVP-UVPO
(1)
BC8 and BC9 are not applicable to fan coils with cover cabinets
(2) compulsory accessory
(2)
SE accessories are matched with ZX feet
71
Technical data
Mod.
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
(1) W
Heating capacity (70°C)
(1) W
(1)
(1)
W l/h
Water flow rate
(1)
(1)
(1) l/h l/h kPa
Pressure drop
Heating capacity (50°C)
(1)
(1)
(2)
(2) kPa kPa
W
W
(2)
(2)
W l/h
Water flow rate
Pressure drop
(2)
(2)
(2)
(2) l/h l/h kPa kPa
(2) kPa
COOLING PERFORMANCE
Total cooling capacity
Sensible cooling capacity
Water flow rate
Pressure drop
Air flow rate
Fans
Absorbed power
Absorbed power with germicidal lamp
Total input power (UV/UVP)
Total input power (UVPO)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3) l/h l/h kPa kPa kPa m 3 /h m
3
/h m 3 /h
W
W
W
W
W
W l/h
W
W
W
A type n°
W
W
W
Sound power level
Sound pressure level
(4)
(4)
(4)
(5)
(5)
A dB(A) dB(A) dB(A) dB(A) dB(A)
(5) dB(A)
Water content
Coil connections l
ø
Vel.
H
M
L
H
M
L
H
M
L
H
M
L
L
H
M
L
H
M
M
L
H
L
H
H
M
M
L
H
M
L
H
M
L
M
L
H
M
L
H
M
L
H
M
L
H
Speed connected
Power supply
H
M
L
FHX22
23
0,79
1/2"
V3
V2
V1
0,37
50
43
31
42
35
1
25
22
19
50
47
44
0,12
210
144
6
5
3
290
220
140
1500
1220
840
1240
1000
670
258
2960
2531
1906
260
222
167
6
4
3
1770
1510
1130
258
210
144
6
5
2
H max. speed; M med. speed; L min. speed
Heating mode
2 pipes system configuration
(1) Room air temperature 20°C b.s.; Inlet water temperature 70°C; DT water 10°C
2 pipes system configuration (EUROVENT)
(2) Room air temperature 20°C b.s.; Inlet water temperature 50°C; Water flow rate as in cooling mode
Cooling mode (EUROVENT)
(3) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperature 7°C; DT water 5°C
(4) Sound power level on the basis of measurements made in compliance with Eurovent 8/2
(5) Sound pressure level (A-weighted) measured in the room with volume V=85m
3
, reverberation time t = 0.5 s; Direction factor Q = 2; Distance r = 2.5m
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com
FHX42 FHX50
478
397
15
13
8
9918
5521
4062
581
484
356
15
11
6
3960
3300
2430
585
478
397
14
10
7
600
460
330
3400
2780
2310
2760
2110
1630
585
Centrifugal
29
1,48
3/4"
V3
V2
V1
0,63
51
44
37
43
36
2
57
43
30
82
68
55
0,28
230V/1/50Hz
604
432
19
14
8
720
600
400
4190
3510
2510
3000
2540
1790
721
34
1,48
3/4"
V3
V2
V1
0,48
56
51
42
48
43
2
67
46
34
92
71
59
0,35
604
432
15
11
6
8191
7529
5021
718
660
440
15
13
6
4870
4480
3000
721
FHX32
26
1,11
1/2"
V3
V2
V1
0,57
48
41
34
40
33
2
44
33
25
69
58
50
0,21
316
267
28
17
13
450
350
260
2400
1840
1550
1900
1570
1110
413
5354
4065
3165
470
357
278
20
12
8
3160
2400
2060
413
316
267
16
10
7
FHX62
34
2,52
3/4"
V3
V2
V1
0,92
57
51
42
49
43
3
82
61
40
182
161
140
0,4
752
554
17
14
8
920
720
520
4860
4370
3220
3980
3300
2440
836
12919
10942
8327
1133
960
730
17
12
7
7500
6430
4880
836
752
554
9
7
4
FHX82
43
2,52
3/4"
V3
V2
V1
1,06
61
56
51
53
48
3
106
80
59
206
180
159
0,49
860
738
22
12
9
1140
930
700
6910
5000
4290
5680
3780
2970
1189
15140
13349
10771
1328
1171
945
21
16
11
7960
6860
5200
1189
860
738
21
12
9
72
Dimensions and Weight wall-mounted model with cabinet wall-mounted model without cabinet universal free-standing or wall/ceiling mounting with cabinet
B
C
B
C
universal free-standing or wall/ceiling mounting without cabinet
C
D
B
A
FHX22-32-42-50UV
Mod FHX_UV
Height
Widht
Depth
Weight
A mm
B mm
C mm kg
Mod FHX_UVP/UVPO
Height
Widht
Depth
Weight
A mm
B mm
D (6) mm
C mm kg
(6) Maximum size (including the electrical box)
22
453
522
572
216
16
22
520
750
220
16
A
A
FHX62-82UV
32
453
753
823
216
26
32
520
980
220
26
42
520
1200
220
25
42
453
973
1043
216
25
FHX22-32-42-5062-82UVP/UVPO
50
520
1200
220
25
50
453
973
1043
216
25
62
590
1320
220
35
62
453
1122
1205
216
35
82
590
1320
220
35
82
453
1122
1205
216
35
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577 www.aermec.com
73
PMZ
Plenum with motorized dampers for ducted fan coils
•
MULTIZONE PLENUM TO CONTROL THE AIR FLOW
• TO BE COMBINED WITH FCX_I AND VED_I FAN COILS WITH
INVERTER MOTOR
• PERFECT FOR RESIDENTIAL AND SERVICES SECTORS
APPLICATIONS
• WIRELESS THERMOSTATS
Characteristics
• The plenums with motorized dampers have been designed for residential and service sectors applications. it allows to combine an optimal environmental comfort with an assured energy saving.
More and more in modern systems one needs to have a global climatization through ducted systems. The accessory PMZ, thanks to the
electronic control of dampers, regulates the room comfort, adjusting the air flow to actual needs.
PMZ has been designed to be combined with fan coils with inverter motor.
• The structure is made of galvanized sheet , internally insulated with self-extinguishing material. It is provided with a variable number from 2 to 6 circular attacks, equipped with motorized dampers in two positions
(open/closed) depending on the combined model.
The damper motor is controlled directly from the wireless room thermostat. With the plenum it is provided a room thermostat for each motorized damper.
• Regulation: the regulation system adjusts the
air flow provided by the fan coil according to the number of open dampers.
The state of the damper (open/closed) is regulated by reaching the temperature set in each room.
The control system is also able to control the valves of on / off type, two or three-way valves for two or four pipe configuration.
30°C room air temperature set 25°C damper n°1 open
30°C room air temperature set 25°C damper n°3 open
25°C room air temperature set 25°C damper n°2 closed
74
(1) Alle condizioni di portate aria e acqua nominali
Compatibility Plenum with fancoils
FANCOIL
FCXI20/24P
FCXI30/34P
FCXI40/44P
FCXI50/54P
FCXI80/84P
VED030/040I
VED130/140I
VED230/240I
VED330/340I
VED530/540I
VED730/740I
PLENUM
2 DELIVERIES
PMZ22
PMZ32
PMZ42
-
-
PMZ22
PMZ32
PMZ42
-
-
-
PLENUM
3 DELIVERIES
-
PMZ33
PMZ43
PMZ43
PMZ83
-
PMZ33
PMZ43
PMZ83
-
-
Technical data
Mod. FCXI_P Vel.
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
Heating capacity (50°C)
Water flow rate
(1)
(1)
W l/h
H
H
20
2100
258
24
2320
298
30
3160
380
HEATING PERFORMANCE (4 PIPE CONFIGURATION - with additional heat exchanger)
Heating capacity (70°C) (2) W H 1751 2826
Water flow rate (2) l/h H 154 248
COOLING PERFORMANCE
Total cooling capacity
Water flow rate
Air flow rate
Fans
Max. high static pressure
Absorbed power
Absorbed power (plenum)
(3)
(3)
W l/h m 3 /h type n°
Pa
W
W
H
H
H
H
1500
258
290
1
50
12
1730
298
290
1
50
12
2210
380
450
2
56
13
PLENUM
4 DELIVERIES
-
-
PMZ44
PMZ44
PMZ84
-
-
PMZ44
PMZ84
PMZ504
-
34
3550
482
-
-
40
4240
585
3460
303
44
5250
765
-
-
PLENUM
5 DELIVERIES
-
-
-
-
-
-
-
-
-
PMZ505
PMZ705
50
4900
721
4223
370
54
6100
855
-
-
PLENUM
6 DELIVERIES
-
-
-
-
-
-
-
-
-
-
PMZ706
80
7990
1276
6410
562
84
10207
1479
-
-
2800
482
450
2
56
13
3400
585
4450
765
600 centrifugal
600
2 2
53
17
53
17
5
4190
721
720
2
46
37
4970
855
720
2
46
37
7420
1276
1140
3
30
80
8600
1479
1140
3
30
80
Mod. VED_I Vel.
030 040 130 140 230 240 330 340 530 532 540 541 730 732 740 741
HEATING PERFORMANCE (2 PIPE CONFIGURATION)
Heating capacity (50°C)
Water flow rate
HEATING PERFORMANCE
(4 PIPE CONFIGURATION)
Heating capacity (70°C)
(1)
(1)
(2)
W l/h
W
H 2180 2340 3750 3940 4320 4750 6270 6550 10420
H 279 327 516 566 588 691 860 922 1335
with
BV030
H 2220 -
with
BV130
3780 -
with
BV230
4493 -
with
BV330
5888 -
-
-
13540
11820
1543
-
-
-
8850
17280
2382
-
-
-
22174
19150
2766
-
-
-
14500
Water flow rate
COOLING PERFORMANCE
Total cooling capacity
Water flow rate
Air flow rate
Fans
Max. high static pressure
Absorbed power
Absorbed power (plenum)
(2)
(3)
(3) l/h
W l/h m 3 /h type n°
Pa
W
W
H 196 331 394 515 1188 776 1945 1272
H 1624 1900 2997 3290 3420 4020 5000 5360 7760 7760 8970 8970 13850 13850 16080 16080
H 279 327 516 566 588 691 860 922 1335 1335 1543 1543 2382 2382 2766 2766
H 285 277 433 420 590 570 805
H
1
61
36
1
61
36
2
60
45
2
60
45
2
64
53
2
63
53
3
66
86
775 1520 1520 1500 1500 2410 2410 2350 2350 centrifugal
3 2
64
86
58
205
2
56
185
2
56
205
2
56
185
3
69
370
3
69
363
3
69
370
3
69
363
5
H max. speed;
2 pipes system configuration (EUROVENT)
(1) Room air temperature 20°C b.s.; Inlet water temperare 50°C; Water flow rate as in cooling mode
4 pipes system configuration (with additional heat exchanger) (EUROVENT)
(2) Room air temperature 20°C b.s.; Inlet water temperare 70°C; ΔT water 10°C
Cooling performance (EUROVENT)
(3) Room air temperature 27°C b.s./19°C b.u.; Inlet water temperare 7°C; DT water 5°C
Note: For more information, please refer to the program selection and the technical documentation available on the website www.aermec.com
Dimensions (mm)
A
C
D
Acessories Plenum
Height
Width
Depth
Delivery
Weight
200
200
A
B
C
D n°
Ø kg
B
200
644
380
180
2
200
9
875
380
180
2
200
9
875
380
180
3
200
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.
11
1095
380
180
2
200
10
WARNING
The brackets supplied as standard are higly recommended to install fan coils – from 20 to 54 size – with their plenums
PMZ22 PMZ32 PMZ33 PMZ42 PMZ43 PMZ44 PMZ83 PMZ84 PMZ504 PMZ505 PMZ705 PMZ706
216 216 216 216 216 216 216 216 300 300 351 351
1095
380
180
3
200
13
1095
380
180
4
200
14
1224
380
180
3
200
13
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577 www.aermec.com
1224
380
180
4
200
14
1231
380
180
4
200
22
1231
380
180
5
200
24
1631
380
180
5
200
32
1631
380
180
6
200
35
75
Ventilcassaforma
Template for recessed installation of fancoils in the wall
CHF
CHU L
Ventilcassaforma has been designed to respond to the needs to rationalise spaces to suit modern interior architecture.
Ventilcassaforma is a galvanised template that makes it possible to make a space to house fan coils in the wall. The template will make masonry work easier during the construction of a niche where the fan coil will be installed. When the work is finished, the fan coil will be completely hidden from view.
Ventilcassaforma is available in two versions with the same characteristics but designed to house fan coils from two different series:
- CHU-L for fan coils in the Omnia UL-P series
- CHF for fan coils in the FCX-P , FCX-PV and FCXI-P series in 2 pipe systems, 2 pipe systems with resistance and with
4 pipe systems
Features
• Available in two versions for combined fan coils:
CHU-L: Ventilcassaforma for the
OMNIA UL-P series. Available in four sizes
CHF: Ventilcassaforma for FCX-P , FCX-PV and FCXI-P fan coils. Available in 5 sizes
• Compatible with VMF System
• Ventilcassaforma is made up of the following parts to be assembled:
- Recess box;
- Closure panel;
- Outer frame with deflector;
- Cover bases, cross-members, covers.
All parts are made of galvanised steel and treated with epoxy-polyester resinbased thermo-hardening base paint in grey with rough glazed finish in order to hold the paint. The final colour can be chosen by the client.
• Closure Panel: Made of galvanised steel, this is the box housing the fan coil. The box is recessed in the wall during building work making the construction of a niche where the fan coils will be installed much easier. Holes for fitting the fan coil and preparing an electric plant with a socket and GEWISS fuse holder are already present on the back panel. The box can accommodate the hydraulic system pipes and condensation drain pipes thanks to the presence of several easily-removable elements on the sides and base.
• Closure Panel: made of steel pre-treated with base paint and no slots present.
Easily removable for servicing and cleaning the air filter.
• Outer Frame: the perimeter of the box has an outer frame made of pre-treated steel making it possible to cover the perimeter part of the wall and hide any imperfections that overtime show possible crumbling on the edge of the plaster work.
• Deflector: manual, with which the flow of air can be directed into the room. The deflector is incorporated in the frame.
76
Ventilcassaforma - Omnia UL combination
Ventilcassaforma
Fan coil
Ventilcassaforma CHU L + Omnia UL combination
CHU 12 L CHU 17 L
Omnia UL 11 P Omnia UL 16 P
CHU 27 L
Omnia UL 26 P
CHU 37 L
Omnia UL 36 P
Ventilcassaforma
Fan coil
CHF 17
FCX 17 P
FCX 17 PV
Ventilcassaforma CHF + FCX P - FCX PV - FCXI P combination
CHF 22
FCX 22 P
FCX 22 PV
CHF 32
FCX 32 P - 36 P
FCX 32 PV - 36 PV
CHF 42
FCX 42 P - 50 P - 56 P
FCX 42 PV - 50 PV - 56 PV
FCX 24 P
FCX 24 PV
FCXI 20/24 P
FCX 34 P
FCX 34 PV
FCXI 30/34/36 P
FCX 44 P - 54 P
FCX 44 PV - 54 PV
FCXI 40/44 P - 50/54/56 P
CHF 62
FCX 62 P - 82 P - 102 P
FCX 62 PV - 82 PV - 102 PV
FCX 64 P - 84 P
FCX 64 PV - 84 PV
FCXI 80/84 P
The fan coils FCX-P , FCX-PV and FCXI-P can be inserted into 2 pipe systems, 2 pipe systems with resistance and 4 pipe systems
Dimensions (mm)
CHU
Height
Width
Depth
A
A1
B
B1
C
12 L
691
648
692
644
186
17 L
691
648
802
754
186
27 L
691
648
1032
984
186
37 L
691
648
1252
1204
186
CHF
Height
Width
Depth
A
A1
B
B1
C
17
728
684
732
684
240
22
728
684
842
794
240
32
728
684
1073
1025
240
42
728
684
1293
1245
240
62
833
789
1414
1366
240
Outer frame and closure panel
CHU
Height
Width
A
A1
A2
A3
B
B1
12 L
724
634
70
494
713
633
17 L
724
634
70
494
823
743
27 L
724
634
70
494
1053
973
37 L
724
634
70
494
1273
1193
CHF
Height
Width
A3
A4
B
B1
A
A1
A2
17
760
680
93
493
94
753
673
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.
22
760
680
93
493
94
863
783
32
760
680
93
493
94
1094
1014
42
760
680
93
493
94
1314
1234
62
865
785
93
598
94
1435
1355
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293577 www.aermec.com
A4
77
Control panels
Range of control panels for fan coils
• WIDE RANGE OF CONTROL PANELS FOR AN EASY AND
COMPLETE CONTROL OF ALL FUNCTIONS OF THE FAN COIL
WMT21: Electronic thermostat for inverter fan coils installed in:
1.
2.
2-pipe systems
4-pipe systems
Overall dimensions (mm):
H=87 - W=132 - D=31
Features and standard equipment
•
Wall-mount installation
• Automatic / manual season change
• Thermostated control of up to 2 On/Off valves
• Temperature and ventilation (3 speeds) control or continuous adjustment
• Internal air probe
Accessories manageable (1) by type of system
Hot water valve
Cold water valve
Air probe (SWAI)
Water probe (SWAI)
2 pipes
•
•
•
•
2 pipes with resistance
-
-
-
-
4 pipes
•
•
•
•
FMT21 : Electronic thermostat for fan coils installed in:
1. 2-pipe systems
2. 2-pipe systems with resistance
3. 4-pipe systems
Overall dimensions (mm):
H=80 - W=113 - D=50
Features and standard equipment
• Recessed installation (module 503 box)
• Automatic / manual season change
• Control of up to 2 On/Off valves, or 1 valve and 1 resistance
• Temperature and ventilation (3 speeds) control
• Internal air probe
Accessories manageable (1) by type of system
Hot water valve
Cold water valve
Air probe (SWA)
Water probe (SWA)
SIT3
SIT5
Electric resistance
2 pipes
-
•
•
•
•
-
-
2 pipes with resistance
-
-
•
•
•
•
•
-
•
•
-
-
4 pipes
•
•
TPF: Electronic thermostat with thermostated or continuous ventilation for fan coils in:
1.
2.
2-pipe systems
4-pipe systems
Overall dimensions (mm):
H=45 - W=75 - D=46
Features and standard equipment
• Recessed installation (module 503 box)
• Automatic / manual season change
• Control of up to 2 On/Off valves,
• Temperature and ventilation control
• Internal air probe
• Water probe (supplied)
Accessories manageable (1) by type of system
Hot water valve
Cold water valve
Air probe
Electric resistance
2 pipes
•
•
-
-
2 pipes with resistance
-
•
-
•
4 pipes
•
•
-
-
Features and standard equipment
• Wall-mount installation
• Automatic / manual season change
• Control of up to 2 On/Off valves
• Temperature and ventilation (3 speeds) control
• Internal air probe
• Louvre and external contact management
PXAE: Electronic thermostat with thermostated or continuous ventilation for fan coils in:
1.
2.
2-pipe systems
4-pipe systems
Overall dimensions (mm):
H=148 - W=70 - D=27.5
Accessories manageable (1) by type of system
Hot water valve
Cold water valve
Water probe (SW3)
SIT3 e SIT5
2 pipes
-
•
•
•
2 pipes with resistance
-
•
•
•
4 pipes
•
•
•
•
PXAR: Electronic thermostat with thermostated or continuous ventilation for fan coils in:
1. 2-pipe systems with resistance
Overall dimensions (mm):
H=148 - W=70 - D=27.5
78
Features and standard equipment
• Wall-mount or fan coil installation
• Automatic / manual season change
• Control of up to 1 On/Off valve and 1 resistance
• Temperature and ventilation (3 speeds) control
• Internal air probe
• Louvre and external contact management
Accessories manageable (1) by type of system
Cold water valve
SIT3 e SIT5
Water probe (SW3)
Electric resistance
2 pipes
-
-
-
-
2 pipes with resistance
•
•
•
•
4 pipes
-
-
-
-
PXBI: Control panel for fan coils in:
1. 2-pipe systems with or without valve
Features and standard equipment
• Fan coil installation
• Manual season change
• Control of up to 1 On/Off valve,
• Temperature and ventilation (3 speeds) control
• Internal air probe
Overall dimensions (mm):
H=145 - W=70 - D=29
Accessories manageable (1) by type of system
Hot water valve
Cold water valve
SIT3 e SIT5
2 pipes
•
•
•
2 pipes with resistance
-
-
-
4 pipes
-
-
-
PXAI: Electronic thermostat with thermostated or continuous ventilation for fan coils in:
1.
2.
2-pipe systems
4-pipe systems
Overall dimensions (mm):
H=148 - W=70 - D=27.5
Features and standard equipment
• Fan coil installation
• Automatic / manual season change
• Control of up to 2 On/Off valves
• Temperature and ventilation (3 speeds) control
• Internal water (2.5m) and air (2.3m) probes
• Louvre and external contact management
Accessories manageable (1) by type of system
Hot water valve
Cold water valve
SIT3 e SIT5
2 pipes
•
•
•
2 pipes with resistance
-
•
•
4 pipes
•
•
•
Features and standard equipment
• Even wall-mount installation with the fixing brackets
• Automatic / manual season change
• Control of up to 2 On/Off valves,
• Temperature and ventilation (3 speeds) control
• Air probe inside the function remote control (IFEEL)
• Air probe supplied for installation in fan coil intake
KTLM: Control thermostat kit
(remote control and receiver) for fan coils with casing in:
1.
2.
2-pipe systems with or without valve
4-pipe systems with valve
Accessories manageable (1) by type of system
Hot water valve
Cold water valve
Electric resistance
2 pipes
-
•
-
2 pipes with resistance
-
•
•
4 pipes
•
•
-
PTI: Control panel for fan coils in:
1. 2-pipe systems with or without valve
Features and standard equipment
• Fan coil installation
• Automatic / manual season change
• Temperature and ventilation (3 speeds) control
• Internal water (2.5m) and air (2.3m) probes
NEW
PTI2: Control panel for fan coils INVERTER with case:
1. 2-pipe systems with or without valve
2. 4-pipe systems with valve
Features and standard equipment
• Fan coil installation
• Automatic / manual season change
• Control of up to 2 On/Off valves
• Temperature and ventilation (3 speeds) control
• Air probe inside the remote control
• Internal water probe for the control of the minimum or maximum, depending on the plant
Accessories manageable (1) by type of system
Hot water valve
Cold water valve
Electric resistance
2 pipes
-
•
-
2 pipes with resistance*
-
•
•
* is possible too handling the Plasmacluster filter, or germicidal lamp, contact us
4 pipes
•
•
-
Accessories manageable (1) by type of system
Hot water valve
Cold water valve
SIT3 e SIT5
2 pipes
•
•
•
2 pipes with resistance
-
-
-
4 pipes
-
-
-
Features and standard equipment
• Even wall-mount installation with the fixing brackets
• Automatic / manual season change
• Control of up to 2 On/Off valves
• Air probe inside the remote control
• Air probe provided for possible fan coil installation
KTLP: Control thermostat kit
(remote control and receiver) for ducted fan coils in:
1.
2.
2-pipe systems with or without valve
4-pipe systems with valve
Accessories manageable (1) by type of system
Hot water valve
Cold water valve
Electric resistance
2 pipes
-
•
-
2 pipes with resistance
-
•
•
4 pipes
•
•
-
Features and standard equipment
• Wall-mount installation
• Ventilation control (3 speeds)
Features and standard equipment
• Wall-mount or fan coil installation
• Ventilation control (3 speeds)
PX2: Commutator switch for fan coils in:
1. 2-pipe systems without valve
PX2C6 : Pack of 6 pcs.
Overall dimensions (mm):
H=145 - W=70 - D=29
Accessories manageable (1) by type of system
Hot water valve
Cold water valve
SIT3
2 pipes
-
-
•
2 pipes with resistance
-
-
-
4 pipes
-
-
-
PX: Commutator switch for fan coils in:
1. 2-pipe systems
Features and standard equipment
• Wall-mount installation
• Manual season change
• Thermostated control of up to 2 On/Off valves
• Temperature and ventilation (3 speeds) control
• Internal air probe
Accessories manageable (1) by type of system
Hot water valve
Cold water valve
SIT3
2 pipes
•
•
•
2 pipes with resistance
-
-
-
4 pipes
-
-
-
WMT06: Electromechanical thermostat with continuous ventilation for fan coils in:
1.
2.
2-pipe systems
4-pipe systems
Accessories manageable (1) by type of system
Hot water valve
Cold water valve
SIT3
Resistance
2 pipes
•
•
•
-
2 pipes with resistance
-
-
-
•
4 pipes
•
•
-
-
Overall dimensions (mm):
H=75 - W=127 - D=25
Features and standard equipment
• Wall-mount installation
• Manual season change
• Temperature and ventilation (3 speeds) control
• Internal air probe
WMT05: Electromechanical thermostat with thermostated ventilation for fan coils in:
1. 2-pipe systems without valve
Overall dimensions (mm):
H=75 - W=127 - D=25
Accessories manageable (1) by type of system
SIT3
2 pipes
•
2 pipes with resistance
-
4 pipes
-
Features and standard equipment
• Wall-mount installation
• Automatic / manual season change
• Control of up to 2 On/Off valves, or 1 valve and 1 resistance
• Temperature and ventilation (3 speeds) control
• Air probe (supplied) to be installed on the fan coil intake
FMT10: Electronic thermostat for fan coils in:
1.
2.
3.
2-pipe systems
2-pipe systems with resistance
4-pipe systems
Overall dimensions (mm):
H=80 - W=118 - D=40
Accessories manageable (1) by type of system
Hot water valve
Cold water valve
Resistance
2 pipes
•
•
-
2 pipes with resistance
-
•
•
4 pipes
•
•
-
WMT10: Electronic thermostat with thermostated or continuous ventilation for fan coils in:
1.
2.
3.
2-pipe systems
2-pipe systems with resistance
4-pipe systems
Overall dimensions (mm):
H=75 - W=127 - D=25
Features and standard equipment
• Wall-mount installation
• Manual season change
• Control of up to 2 On/Off valves,
• Temperature and ventilation (3 speeds) control
• Internal air probe
Accessories manageable (1) by type of system
Hot water valve
Cold water valve
Resistance
2 pipes
•
•
-
2 pipes with resistance
•
-
•
Aermec reserves the right to make all the modifications deemed necessary for improving the product, including technical data.
4 pipes
•
•
-
(1) for the names of the accessories refer to the fan coil technical sheets.
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 039 0442633111 - Telefax +39 044293577 www.aermec.com
79
VMF
Variable Multi Flow system
Range of components for the management of air conditioning, heating and domestic hot water systems
Accessory module
Zone interface VMF systems central interface
NEW
VMF-E4D
VMF-E4
*As awared by Chicago Athenaeum:
Museum of the Architecture and Design
Zone interface
VMF-E5N / VMF-E5B
Thermostat with serial communication
VMF-VOC
VMF-CRP
Domestic water panel
VMF-E0
VMF-E1 / VMF-E18
VMF-E2
VMF-E2H
VMF-SW / VMF-SW1
VMF-ACS
* Winner for the International design Award "Good Design 2010" for the "Electronics"
Features
• VMF: Variable Multi Flow system.
Management and control system of hydronic systems for the conditioning, heating and production of domestic hot water.
The VMF system allows complete control of every component of a hydronic system both locally and centrally and, communicating between the various components of the system, manages the performance without ever neglecting the end user's request of comfort, but reaching it as efficiently as possible with energy saving.
If you add the advantages deriving from such an innovative control to the flexibility of a hidronic system, you get a more efficient and effective alternative to the variable refrigerant flow systems (VRF).
The VMF system is extremely flexible, enough to allow various control and manage steps, expandable at different moments:
1) Control of a single fancoil.
2) Control of a microzone (one MASTER fancoil and a maximum of 5 SLAVE fancoils).
3) Control of multi independent zones system
(one MASTER fancoil and a maximum of 5
SLAVE fancoils for each zone).
4) Control of a fancoil system, plus management of the heat pump (if compatible with the VMF system).
5) Control of a fancoil system, heat pump and management of the domestic hot water system (VMF-ACS).
6) Control of a fancoil system, heat pump, domestic hot water production and additional circulators (up to a maximum of 12 using three additional VMF-CRP modules).
7) Control of a fancoil system, heat pump, domestic hot water production, additional circulators and management of heat recovery units, maximum 3, (with the ability to handle up to 3 VMF-VOC sensors) or a boiler.
• The VMF system can operate and manage, through a VMF-E5N / VMF-E5B panel, a maximum of 64 zones consisting of a
MASTER fancoil and a maximum of 5 SLAVE fancoils connected to each MASTER, for a total of 384 fancoils.
• Besides the central control supplied by theVMF-E5N / VMF-E5B panel, the MASTER fancoils must be provided with a local control interface; this interface can be mounted on the fancoil (VMF-E2 / VMF-E2H) or be mounted into a wall panel (VMF-E4).
• Different functions can be controlled through the VMF-E5N / VMF-E5B panel, including:
- Identify the different zones setting a name for each one.
- Check and set the ON-OFF function and the set temperature of each zone.
- Set and manage the set temperature of the heat pump.
- Scheduling time slots.
• Simple installation of the fancoil system through the SELF-MONITORING function of the MASTER fancoils.
80
System components
• VMF-E0: thermostat accessory to fix on the side of the fancoil, equipped with air and water sensors as standard, controls 2 pipes, 4 pipes,
2 pipes + Plasmacluster, 2 pipes + UV lamps,
2 pipes + Electric heater systems. Equipped with external contact to be used as low voltage remote ON-OFF. This thermostat can create a single fancoil zone through 2-wire serial communication (1 master + 5 slaves maximum). The thermostat is fuse protected.
• VMF-E1: like VMF-E0 with extra:
- Economy contact/presence sensor.
- Auxiliary water sensor for general control in
4-tube systems (with VMF-SW1 accessory).
- Serial RS485, protocol ModBus RTU, for centralised control.
- Possibility to insert expansion cards for future development. The VMF-E1 accessory must therefore be used in the Masters in the presence of multiple zones, or for communication with the chiller/heat pump.
• VMF-E18: the same as the VMF-E1, but for fancoils with inverter motors.
• VMF-E2: this is the user interface on the machine to match to the VMF-E0, VMF-E1 and E18 accessories for the series UL-S-FCX-
AS, FCX-U (sizes 62-64-82-84-102) FCX180U
FHX-U (sizes 62-82). Equipped with 2 selector switches, one for temperature and one for speed control.
• VMF-E2D: is the user interface (as above) on the machine, to combine with accessories
VMF and VMF-E0-E1, dedicated to the series
DUALJET.
• VMF-E2H: this is the User Interface (as above) on the machine, to match to the VMF-E0, E1, accessories dedicated to the HL series
• VMF-E4: this is the wall mounted user interface, to match to the VMF-E0, VMF-E1 and
VMF-E18 accessories for the UL, HL, and
FCX series without on-board control.
Innovative design, extremely slim and inexpensive, allows control of functions via a capacitive touch keypad with LCD display.
The environment can be adjusted with the sensor on the panel (standard), or the sensor of the fancoil which it is connected to, or by their arithmetic mean. It also allows the activation of the air purifier accessory
(Plasmacluster / UV Lamp) and the electrical heating element.
• VMF-E4D:is the variant of the previous code, but with frontal gray Pantone 425C (METAL)
• VMF-E5B: white recessed panel, with backlit graphic LCD and capacitive keyboard allows the centralised command/control of a complete hydronic system consisting of Fancoils: up to 64 fancoil zones consisting of a master
+ 5 slaves. Chiller/heat pump equipped with
Modu_Control, GR3 and pCO2/PCO³ controls (accessory required for RS 485 interface with MODU-485A, AER485, AER485P2 /
AER485P1); circulators: up to 12 configurable zone circulators; boiler: boiler consensus management for hot water production; heat recovery units: consents up to 3 per programmable recovery units based on the timing and/or by measuring the air quality obtained with the VMF-VOC accessory; domestic water module: complete management of the domestic hot water production through the control of: diverting/circulator valve, integrated resistor, accumulation temperature sensor, antilegionella circuit.
• VMF-E5N: this is the variant of the previous code, but with black plastic.
• VMF-VOC : accessories for measuring air quality (see related point in the description of the VMF-E5B).
• VMF-CRP: accessory module for the control of the boilers, pumps and heat recovery units.
•
VMF-SIT3: Interface cards that allow you to connect the thermostats VMF and VMF-E0-E1 to a fan motor with high power (for selection see all the documentation of the thermostat and the fan coil).
• VMF-SW: water sensor may be used in place of the standard supplied with VMF-E0, VMF-
E1 and VMF-E18 thermostats for the installation upstream of the valve.
• VMF-SW1: additional water sensor may be used for 4-pipe systems with VMF-E1 and E18 thermostats for the maximum control in the cold range.
• VMF-ACS3KM: electrical panel for the complete command/control for hot water storage
(3-way control valve, integrated single phase
3kW resistor command, Anti-legionella and temperature sensor).
• VMF-ACS3KTN: electrical panel for the complete command/control for hot water storage
(3-way control valve, integrated three-phase
3kW resistor command, Anti-legionella and temperature sensor).
• VMF-ACS6KTN: electrical panel for the complete command/control for hot water storage
(3-way control valve, integrated three phase
6kW resistor command, Anti-legionella and temperature sensor).
• VMF-ACS8KTN: electrical panel for the complete command/control for hot water storage
(3-way control valve, integrated three phase
8kW resistor command, Anti-legionella and temperature sensor).
• GLL_N: FCL_N grid units, equipped with thermostat card for serial communication with the accessory functions equivalent and VMF-
E1 (this grid is a mandatory accessory for the units FCL N);
• GLLI_N: FCLI_N grid units, equipped with thermostat card for serial communication with the accessory functions equivalent and
VMF-E18, (this grid is a mandatory accessory for the units FCLI N);
Dimensions (mm)
A B C
[mm] [mm] [mm]
VMF-E5B / VMF-E5N 138
VMF-E4 / VMF-E4D 125
110
80
45
11
VMF-ACS 354 544 135
VMF-VOC 79 81 26
VMF-E5B / VMF-E5N
VMF-E4 / VMF-E4D VMF-ACS VMF-VOC
81
Selection 1 • Compatibility of thermostats for serial communication and control interface for MASTER units mod.
FCX
FCXI
HL
UL
FHX
VEC
FCL
FCLI
VED
FCW
DUALJET
Versions
AS - UA - B
U
P - PPC - PO - PV
AS
U
P
S - SM
N
S
P
R
UV
UVP - UVPO
(1)
(7)
N
Note
(8)
(8)
VMF-E0 VMF-E1 VMF-E18 VMF-E2 VMF-E2D VMF-E2H
✔
✔
✔
✔
-
-
✔
✔
-
✔
-
✔
✔
-
✔
-
-
✔
-
✔
✔
✔
✔
-
-
✔
✔
-
✔
-
✔
✔
-
✔
-
-
✔
-
✔
✔
-
-
-
-
-
-
-
-
-
-
-
-
-
✔
-
-
-
✔
(7)
✔
-
✔
(7)
✔
-
-
-
-
-
-
-
-
-
-
-
-
✔
-
✔
(7)
-
-
-
✔
(7)
-
-
-
✔
(7)
-
-
-
-
-
-
-
-
-
✔
-
-
-
-
-
-
✔
-
-
-
-
-
-
-
-
-
-
-
-
✔
✔
✔
✔
✔
✔
✔
✔
✔
VMF-E4 /
VMF-E4D
✔
✔
✔
✔
✔
✔
✔
-
✔
✔
GLL N
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
✔
-
-
Selection 2 • Compatibility of VMF-E5 7 VMF-E5B centralised control mod.
FCX
FCXI
HL
Versions
AS - U - UA - B
P - PPC - PO - PV
AS - U - P
S
P
S - SM
N
(2)
(1)
(2)
(2)
Note
(2)
(2)
(2)
VMF-E5N / VMF-E5B
✔
✔
✔
✔
-
UL
FHX
VEC
FCL
FCLI
VED
FCW
DUALJET
RI
UV - UVP - UVPO
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
✔
✔
✔
✔
✔
✔
✔
✔
N
Selection 3 • Compatibility of heat pumps with electrical panel for domestic hot water management
✔
*
GLLI N
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
✔
-
mod.
ANL
ANLI
ANK
SRA
SRP-V1
NRL
NRC
WSH
Versions
H
Tutte
Tutte
Tutte
Tutte
H
H
Tutte
Note
(3) (4)
(4)
(4)
(4)
(4)
(3) (4)
(3) (4)
(4)
Selection 4 • Compatibility of modules and additional sensors
VMF-ACS3KM
✔
✔
✔
✔
✔
✔
✔
✔
mod.
VMF-E5N/ E5D
VED
RePuro
HRS
Versions
Tutte
Tutte
Note
(5) (6)
(9)
(5) (6)
(5) (6)
VMF-CRP
✔
✔
✔
VMF-ACS3KT
✔
✔
✔
✔
✔
✔
✔
✔
VMF-VOC
✔
(6)
✔
(6)
✔
(6)
VMF-ACS6KT
✔
✔
✔
✔
✔
✔
✔
✔
VMF-ACS8KT
✔
✔
✔
✔
✔
✔
✔
✔
VMF-SIT3
✔
Notes:
The versions with the accessories hanging MA or MP, can be treated equally to their respective versions FCX AS U FCX, FCX AU;
(1) This version includes the thermostat E0-VMF and VMF-E2H command interface already installed, these features make these models suitable for operation as a single unit or function of the MASTER microzone plants (plants consist of a single zone, without centralized contol VMF-E5N / VMF-E5B);
(2) To be compatible with the centralized control of VMF-E5N / VMF-E5B, a fan must be set as MASTER of the area, therefore this must be equipped with the thermostat for serial communications, or VMF VMF-E1-E18 and combined with a user interface ( VMF-E2, or VMF VMF-E2H-E4), or units FCL / FCLI equipped with a thermostat on the grid GLL_N / GLLI_N, combined with a command interface VMF-E4 / VMF-E4D ;
(3) The heat pumps with integrated storage are not suitable for production of hot water;
(4) To know the maximum temperature of hot water production (plant and / or health) refer to the limits on the operating unit technical manual;
(5) All types of systems that provide centralized control of VMF-E5N / VMF-E5B, are compatible with the accessory modules (maximum 4) VMF-CRP, and each module can function as a pump controller (4 for each accessory module) or boiler control and recovery (with ON / OFF control and management of 3 recovery boiler in addition to
3 accessories VMF-VOC);
(6) The compatibility of the probe VMF-VOC is only related to the presence of the accessory module in the system with VMF-CRP control function recovery;
(7) VMF-E2: Only for size FCX62U-64U-82U -84U-102U, FCXI80U, FHX62UV-82UV, for other sizes install VMF-E2D, side connections
(8) units must be included in boxes FCLI GLLI_N mandatory accessory grid, this grid is equipped with a card thermostat same rights as VMF-E18 models.
FCL cassette units must provide the mandatory accessory GLL_N grid, this grid is equipped with a card equivalent and thermostat models VMF-E1. To use one of these drives as MASTER is necessary to provide the command interface VMF-E4;
(9) Accessory units required for the combination of VED with thermostats or VMF VMF-E0-E1. Using a VMF-SIT3 for each unit;
(*) Contact us
82
VMF-E5
MODbus RS485
(MAX 1000m)
Chiller
Example of system components
VMF-CRP
n°1 n°2
• A maximum number of 4 VMF-CRP modules
VOC
- Control 4 pumps
VOC n°4 n°3 n°4
VOC accessories must be purchased)
- Control a boiler
VOC
• The only requirement to install VMF-CRP modules is the presence of a VMF-E5 centralised control
VMF-CRP
n°1
VMF-CRP
n°2 n°2 n°3 n°4 n°3
VMF-ACS
VMF-ACS
n°4
VMF-ACS
• The VMF-ACS accessory allows to control the different components needed to produce domestic hot water; for detailed information on the types of systems manageable by VMF-ACS, refer to technical documentation of the accessory
WARNING: in the case where the plant is provided with accessory Multicontrol it will not be possible to use the accessory VMF-ACS, since the production of
VMF-E5 the accessory Multicontrol.
Chiller
Multicontrol
n°1 n°2 n°3 n°4 n°1 n°2 n°3 n°4
VMF-CRP (Multicontrol)
n°1 n°2 n°3
VOC
VOC
VOC
VOC
VOC
VOC x3
Selection 4:
x3
Selection 3:
VMF-E4
B
VMF-E5
Selection 2:
WARNING:: Each chiller must be provided with the appropriate communications accessory Modu-485A
Chiller 1 (Multicontrol) Chiller 4 (Multicontrol)
MODbus RS485
(MAX 1000m)
Chiller
VMF-E4
A
Fancoil 1
(MASTER)
A
A
A
A
A
B
MODbus RS485
(MAX 1000m)
VMF-E4
Fancoil 1 (Slave)
Fancoil 2 (Slave)
Fancoil 3 (Slave)
Fancoil 4 (Slave)
Fancoil 5 (max) (Slave)
B
B
A
VMF-E4
Fancoil 64 (max)
(MASTER)
A
A
Fancoil 1 (Slave)
A
A
B
A
A
Fancoil 1
MODbus RS485 Multicontrol
B
Fancoil 1 (Slave)
VMF-E4
Fancoil 2 (Slave)
Fancoil 3 (Slave)
B
A
A
A
Fancoil 4 (Slave)
A
Fancoil 4 (Slave)
A
Fancoil 5 (max) (Slave)
Fancoil 3 (Slave)
Fancoil 5 (max) (Slave)
A
Fancoil 4 (Slave)
A
Fancoil 5 (max) (Slave)
A
A
A
A
Fancoil 64 (max)
(MASTER)
Fancoil 2 (Slave)
A
A
A
A
A
(MASTER)
Fancoil 3 (Slave)
A
A
A
Fancoil 3 (Slave)
Fancoil 4 (Slave)
Fancoil 5 (max) (Slave)
A
Thermostat for serial connection VMF-E0 / VMF-E1 / VMF-E18
A
B
Commands interface for MASTER unit VMF-E2 / VMF-E2H / VMF-E4
Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data.
B
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. 0442633111 - Telefax 044293730 www.aermec.com
83
Climafon
Thermoconvectors
Vertical installation residential use
Flat grid, fixed
with aluminum fins
Aermec presents the brand new natural convection heating system in the CLIMAFON system.
CLIMAFON is born from long experience in the heat exchange field gained within the Giordano Riello International Group, a group in which
Aermec is the leading company.
CLIMAFON is a system terminal that works on the basis of natural convection: the air is heated through an exclusive finned exchange and is sent into the room through a flue effect.
Features
• Enhanced Comfort: CLIMAFON heats rooms quickly and naturally because it basis its operation on air moved by simple convection. The use of CLIMAFON with low temperature heating systems (heat pump, condensation boiler, geothermal and solar...) ensures that the rooms are heated without drying the air. It causes a pleasant sensation of wellbeing that helps to survive even the longest and harshest winters in total relaxation.
• Operation at full capacity achieved more
quickly: CLIMAFON has much smaller water content. This enables it to be very fast in heating times and permits it to be used only where it is useful. The speed it takes
CLIMAFON to reach full capacity operation has been checked by TÜV (world leader in product assessment and verification).
• Best quality of the air we breath: the air temperature of the air leaving CLIMAFON is such as not to allow the toasting of the powder in the environment. The result is healthy, clean air. In addition to our health, winners also include the walls of our house (CLIMAFON spells the end to the blackening of walls typical of radiator systems).
• Greater security: CLIMAFON's outer surface reaches a top temperature of 43°C, a value that is totally harmless for our body (the risk of burning is nil). Its rounded form without sharp edges makes the room a safer environment especially for children.
• Greater care to appearance: the soft flowing, modern and elegant lines give CLIMAFON greater appeal that enables it to be integrated with all types of furnishing whether it is traditional or modern.
• Energy saving: the innovative finned exchanger ensures high energy efficiency thanks the possibility of effective use at low temperatures of the warm supply water.
• Easier and faster installation: CLIMAFON is much lighter than a radiator with the same capacity; just one person is needed to handle and install it quickly and easily on all types of wall. CLIMAFON is fitted with an installation template that means the unit can be assembled after the building work has been completed. Costly masonry work typical of radiator installation is avoided: just four blocks are required for fixing CLIMAFON to the wall.
84
Versions
• Available in four sizes Flat grid, fixed with aluminum fins.
• The versions available are double (4 rows of pipes) or treble (6 rows of pipes). Water connections can be reversed during installation phase
Selection
By combining the various options, each model can be configured.
Code:
CLIMAFON
Size :
1, 2, 3, 4
Coil :
2 - Double
3 - Treble
Commercial code example: CLIMAFON 23P
Grille:
P - Flat grid, fixed with aluminum fins
Technical data
Mod. CLIMAFON
Heating capacity
Water flow rate
Water pressure drop
Water contents
Coil connections
Rows of pipes
W l/h kPa l
ø
ø
12P
910
78
0,22
0,5
1/2”
2
13P
1005
87
0,26
0,6
1/2”
3
22P
1350
116
0,50
0,8
1/2”
2
23P
1540
135
0,72
1,1
1/2”
3
Heating (in accordance with UNI EN 442):
– room air temperature 20 °C; hot water temperature (in/out) 75/65°C; DT water 50 °C
32P
1750
150
0,95
1,0
1/2”
2
33P
2001
176
1,36
1,4
1/2”
3
42P
2205
190
1,31
1,1
1/2”
2
43P
2515
221
1,91
1,6
1/2”
3
Dimensions (mm)
B
C
A
Mod. CLIMAFON
Height
Width
Depth
Weight
12P 13P 22P 23P 32P 33P 42P 43P
A mm 630 630 630 630 630 630 630 630
B mm 600 600 800 800 1000 1000 1200 1200
C mm 140 140 140 140 140 140 140 140 kg 12 13 15 16 18 19 21 22
All specifications are subject to change without prior notice.
Although every effort has been made to ensure accuracy, Aermec does not assume responsibility or liability for eventual errors or omissions
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel. +39 04 42 63 31 11 - Telefax +39 044 29 3577 www.aermec.com
85
Climabox
Recessed wall-mounted convection heater
Climabox is the innovative built-in wall convection radiator for heating systems. It was created to meet the needs for space rationalization according to modern architecture criteria for interiors and the current need for energy saving.
Characteristics
• Available in 3 sizes with double or triple battery.
• Climabox consists of several parts to be assembled:
1. Frame in galvanized and painted plate that allows the heat exchanger to be installed in the wall.
2. Heat exchanger
, designed for maximum intensification of the natural convection effect, constructed of copper piping and fining.
3. Closing panel
supplied, which allows the materials, desired look and colour of the panel to be customized. Once the work is complete, the heating unit will be completely hidden from view.
4. Head
Located on the upper horizontal part of the panel, it is available with a fixed metallic grille.
The closing panel and all of the visible parts of the frame are treated so they can be painted with the same paint as the wall.
The Climabox convection heater is the ideal terminal for heating any room. Heat is supplied instantly and uniformly distributed throughout the area.
It can be added to a heating system powered by a boiler, district heating system or heat pump.
The possibility of easily removing the cover allows for thorough cleaning of the interior.
Ease of installation with reversable water attachments in the installation phase. Full compliance with safety and injury prevention regulations
Head closing panel
Frame in galvanized plate
Heat exchange battery
Unit choice
Any model can be configured by changing the available options.
Logo:
CLIMABOX
Size:
2, 3, 4
86
Battery:
2 - Double
3 - Triple
Grille:
Fixed grille
advertisement
Key Features
- Vertical and horizontal installation
- Quiet operation
- Adjustable air delivery louver
- Electronic temperature control
- Water connections reversibility
- Low pressure drop
- Easy installation and maintenance
- Full compliance with safety regulations
- Inverter Brushless motor
- Energy saving