DEWE-2600 Technical reference manual

DEWE-2600 Technical reference manual
Automotive
Energy & Power Analysis
Aerospace
Transportation
General Test & Measurement
DEWE-2600
Technical reference manual
ISO9001
www.dewetr o n .c o m
Copyright © DEWETRON elektronische Messgeraete Ges.m.b.H.
This document contains information which is protected by copyright. All rights are reserved. Reproduction,
adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws.
All trademarks and registered trademarks are acknowledged to be the property of their owners.
Preface
Thank you!
Thank you very much for your investment in DEWETRON's unique data acquisition systems. These are
top-quality instruments which are designed to provide you years of reliable service. This guide has been
prepared to help you get the most from your investment, starting from the day you take it out of the box, and
extending for years into the future.
This guide includes important startup notes, as well as safety notes and information about keeping your
DEWETRON system in good working condition over time.
We strongly suggest that you read this entire manual, especially the safety and care sections, as well as to
avoid damaging your DEWETRON system.
What is the DEWE-2600 ?
This product is used for measuring of different physical and/or electrical sizes (depending on model or configuration). The connection is depending on model or configuration and takes place via safety banana plugs, BNC connectors (± 50V max.), D-SUB connectors (± 50V max.), thermocouple connectors (± 50V max.), BINDER® connectors (± 50V max.) or LEMO® connectors.
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
3
Preface
Notes
4
Table of content
Content
General Information, Safety Instructions
7
Training………………………………………………………………………………………… 7
Calibration……………………………………………………………………………………… 7
Support………………………………………………………………………………………… 7
Service/repairs………………………………………………………………………………… 7
Warranty Information… ……………………………………………………………………… 8
Printing History………………………………………………………………………………… 8
Safety symbols in the manual… …………………………………………………………… 9
General safety and hazard warnings for all DEWETRON systems… ………………… 10
Windows updates and antivirus/security software………………………………………… 13
Problematic network stacks… ……………………………………………………………… 13
Environmental Considerations… …………………………………………………………… 13
Blockdiagram of the internal signal processing… ………………………………………… 14
First steps……………………………………………………………………………………… 15
Main System
17
DEWE-2600 series instruments… ………………………………………………………… 17
System specifications………………………………………………………………………… 17
Connectors… ………………………………………………………………………………… 19
Possible configurations… …………………………………………………………………… 22
DAQ series modules overview… …………………………………………………………… 24
MDAQ series amplifiers overview…………………………………………………………… 26
Maintenance…………………………………………………………………………………… 33
Software
35
DEWESoft……………………………………………………………………………………… 35
A/D & D/A Conversion
A1
Internal Wiring
B1
CE-Certificate of conformity
C1
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
5
Table of content
6
General Information, Safety Instructions
Services
Training
DEWETRON offers training at various offices around the world several times each year. DEWETRON
headquaters in Austria have a very large and professional conference and seminar center, where training
classes are conducted on a regular basis starting with sensors and signal conditioning, A/D technology and
software operation. For more information about training services, please visit:
http://www.dewetron.com/support/training
Dewetron Inc. in the USA also has a dedicated training facility connected to its headquarters, located in
Rhode Island. For more information about training services in the US, please visit:
http://www.dewamerica.com/support/training
Calibration
Every instrument needs to be calibrated at regular intervals. The standard norm across nearly every industry
is annual calibration. Before your DEWETRON data acquisition system is delivered, it is calibrated at our
DEWETRON headquater. Each of this system is delivered with a certificate of compliance with our published
specifications. Detailed calibration reports from our calibration system are available for purchase with each
order. We retain them for at least one year, so calibration reports can be purchased for up to one year after
your system was delivered.
Support
DEWETRON has a team of people ready to assist you if you have any questions or any technical difficulties
regarding the system. For any support please contact your local distributor first or DEWETRON directly.
For Asia and Europe, please contact:
For the Americas, please contact:
DEWETRON Ges.m.b.H.
Parkring 4
A-8074 Graz-Grambach
AUSTRIA
Tel.: +43 316 3070
Fax: +43 316 307090
Email: [email protected]
Web: http://www.dewetron.com
DEWETRON, Inc.
10 High Street, Suite K
Wakefield, RI 02879
U.S.A.
Tel.:
+1 401 284 3750
Toll-free: +1 877 431 5166
Fax:
+1 401 284 3755
Email: [email protected]
Web:
http://www.dewamerica.com
The telephone hotline is available
Monday to Friday between
08:00 and 17:00 CET (GMT +1:00)
The telephone hotline is available
Monday to Friday between
08:00 and 17:00 GST (GMT -5:00)
Service/repairs
The Team of DEWETRON also performs any kinds of repairs to your system to assure a safe and proper
operation in future. For information regarding service and repairs please contact your local distributor first or
DEWETRON directly.
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
7
Notice
The information contained in this document is subject to change without notice.
DEWETRON elektronische Messgeraete Ges.m.b.H. (DEWETRON) shall not be liable for any errors
contained in this document. DEWETRON MAKES NO WARRANTIES OF ANY KIND WITH REGARD
TO THIS DOCUMENT, WHETHER EXPRESS OR IMPLIED. DEWETRON SPECIFICALLY DISCLAIMS
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
DEWETRON shall not be liable for any direct, indirect, special, incidental, or consequential damages,
whether based on contract, tort, or any other legal theory, in connection with the furnishing of this document
or the use of the information in this document.
Warranty Information
A copy of the specific warranty terms applicable to your DEWETRON product and replacement parts can be
obtained from your local sales and service office.
Restricted Rights Legend
Use austrian law for duplication or disclosure.
DEWETRON GesmbH
Parkring 4
A-8074 Graz-Grambach / Austria
Printing History
Please refer to the page bottom for printing version.
Copyright © DEWETRON elektronische Messgeraete Ges.m.b.H.
This document contains information which is protected by copyright. All rights are reserved. Reproduction,
adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright
laws.
All trademarks and registered trademarks are acknowledged to be the property of their owners.
8
Safety instructions
Safety symbols in the manual
Indicates hazardous voltages.
WARNING
Calls attention to a procedure, practice, or condition that could cause bodily
injury or death.
CAUTION
Calls attention to a procedure, practice, or condition that could possibly cause
damage to equipment or permanent loss of data.
WARNINGS
The following general safety precautions must be observed during all phases of operation, service, and
repair of this product. Failure to comply with these precautions or with specific warnings elsewhere in this
manual violates safety standards of design, manufacture, and intended use of the product. DEWETRON
Elektronische Messgeraete Ges.m.b.H. assumes no liability for the customer’s failure to comply with these
requirements.
All accessories shown in this document are available as option
and will not be shipped as standard parts.
For safety reasons max. 50 V may be applied to the BNC input-connectors! Refer to the regulation of maximum allowable touch potential.
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
9
Safety instructions
Your safety is our primary concern! Please be safe!
General safety and hazard warnings for all DEWETRON systems
Use this system under the terms of the specifications only to avoid any possible danger.
Maintenance will be executed by qualified staff only.
During the use of the system, it might be possible to access another parts of a more comprehensive system. Please read and follow the safety instructions provided in the manuals of all other components regarding warning and security advices for using the system.
With this product, only use the power cable delivered or defined for the host country.
DO NOT connect or disconnect sensors, probes or test leads, as these parts are connected to a voltage supply unit.
The system is grounded via a protective conductor in the power supply cord. To avoid electric shocks, the protective conductor has to be connected with the ground of the power network. Before connecting the input or output connectors of the system, make sure that there is a proper grounding to guarantee
potential free usage. For countries, in which there is no proper grounding, please refere to your local legally safety regulations for safety use.
DC systems: Every DC system has a grounding connected to the chassis (yellow/green safety banana plug).
Please note the characteristics and indicators on the system to avoid fire or electric shocks. Before connecting the system, please carefully read the corresponding specifications in the product manual.
The inputs are not, unless otherwise noted (CATx identification), for connecting to the main circuit of category II, III and IV.
The power cord separates the system from the power supply. Do not block the power cord, since it has to be accessible for the users.
DO NOT use the system if equipment covers or shields are removed.
If you assume the system is damaged, get it examined by authorised personnel only.
Any use in wet rooms, outdoors or in adverse environmental condition is not allowed!
Adverse environmental conditions are:
Moisture or high humidity
Dust, flammable gases, fumes or dissolver
Thunderstorm or thunderstorm conditions (except assembly PNA)
Electrostatic fields, et cetera.
The measurement category can be adjusted depending on module configuration.
Any direct voltage output is protected with a fuse against short cut and reverse-polarity, but is NOT galvanically isolated (except it is explicit marked on the system).
The system must be connected and operated to an earthed wall socket at the AC mains power supply only (except for DC systems).
Any other use than described above may damage your system and is attended with dangers like shortcut, fire or electric shocks.
The whole system must not be changed, rebuilt or opened (except for changing DAQ, DAQP, PAD modules).
10
Safety instructions
If you assume a more riskless use is not provided anymore, the system has to be rendered inoperative and should be protected against inadvertent operation. It is assumed that a more riskless operation is not possible anymore, if
the system is damaged obviously or causes strange noises.
the system does not work anymore.
the system has been exposed to long storage in adverse environmental.
the system has been exposed to heavy shipment strain.
DO NOT touch any exposed connetors or components if they are live wired. The use of metal bare wires is not allowed. There is a risk of short cut and fire hazard!
Warranty void if damages caused by disregarding this manual. For consequential damages NO liability will be assumed!
Warranty void if damages to property or persons caused by improper use or disregarding the safety instructions.
Unauthorized changing or rebuilding the system is prohibited due to safety and permission reasons (CE).
Exception: changing modules like DAQ, DAQP or PAD.
The assembly of the system is equivalent to protection class I. For power supply, only the correct power socket of the public power supply must be used, except the system is DC powered.
Be careful with voltages >25 VAC or >35 VDC! These voltages are already high enough in order to get a perilous electric shock by touching the wiring.
The product heats during operation. Make sure there is adequate ventilation. Ventilation slots must not covered!
Only fuses of the specified type and nominal current may be used. The use of patched fuses is prohibited.
Prevent using metal bare wires! Risk of short cut and fire hazard!
DO NOT use the system before, during or shortly after a thunderstorm (risk of lightning and high energy
overvoltage). An advanced range of application under certain conditions is allowed with therefore designed products only. For details please refer to the specifications.
Make sure that your hands, shoes, clothes, the floor, the system or measuring leads, integrated curcuits and so on, are dry.
DO NOT use the system in rooms with flammable gases, fumes or dust or in adverse environmental conditions.
Avoid operation in the immediate vicinity of:
high magnetic or electromagnetic fields
transmitting antennas or high-frequency generators
For exact values please refere to enclosed specifications.
Use measurement leads or measurement accessories aligned to the specification of the system only. Fire hazard in case of overload!
Do not switch on the system after transporting it from a cold into a warm room and vice versa. The thereby created condensation may damage your system. Acclimatise the system unpowered to room temperature.
Do not disassemble the system! There is a high risk of getting a perilous electric shock. Capacitors still might charged, even the system has been removed from the power supply.
The electrical installations and equipments in industrial facilities must be observed by the security regulations and insurance institutions.
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
11
Safety instructions
The use of the measuring system in schools and other training facilities must be observerd by skilled personnel.
The measuring systems are not designed for use at humans and animals.
Please contact a professional if you have doubts about the method of operation, safety or the connection of the system.
Please be careful with the product. Shocks, hits and dropping it from already lower level may damage your system. For exact values please refere to enclosed specifications.
Please also consider the detailed technical reference manual as well as the security advices of the connected systems.
This product has left the factory in safety-related flawless and proper condition.
In order to maintain this condition and guarantee safety use, the user has to consider the security advices
and warning in this manual.
12
General Information
CAUTION
The system BIOS is protected by password. Any change in the BIOS may cause a system crash.
When the system is booting, do not press ESC-button on keyboard. This may clear the BIOS settings
and cause system faults.
Any change in the file structure as deleting or adding files or directories might cause a system crash.
Before installing software updates contact DEWETRON or your local distributor. Use only software
packages which are released by DEWETRON. Further informations are also available in the internet
(http://www.dewetron.com).
After power off the system wait at least 10 seconds before switching the system on again. Otherwise
the system may not boot correct. This prolongs also the life of all system components.
Windows updates and antivirus/security software
Before installing Windows software updates consult with DEWETRON for compatibility guidance. Please
also keep in mind that the use of any antivirus or other security software may slow down your system and
may cause data loss.
Problematic network stacks
Often intrusive IT software or network processes can interfere with the primary function of the DEWETRON
system: to record data. Therefore we recommend strongly against the installation of IT/MIS software
and running their processes on any DEWETRON data acquisition system, and cannot guarantee the
performance of our systems if they are so configured.
Environmental Considerations
Information about the environmental impact of the product.
Product End-of-Life Handling
Observe the following guidelines when recycling a DEWETRON system:
System and Components Recycling
Production of these components required the extraction and use of natural resources. The
substances contained in the system could be harmful to your health and to the environment if the system
is improperly handled at it's end of life! Please recycle this product in an appropriate way to avoid an
unnecessary pollution of the environment and to keep natural resources.
This symbol indicates that this system complies with the European Union’s requirements according to
Directive 2002/96/EC on waste electrical and electronic equipment (WEEE). Please find further informations
about recycling on the DEWETRON web site
www.dewetron.com
Restriction of Hazardous Substances
This product has been classified as Monitoring and Control equipment, and is outside the scope of the
2002/95/EC RoHS Directive. This product is known to contain lead.
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
13
Signal processing
Blockdiagram of the internal signal processing
AC or DC input
Power
supply
USB and FireWire power supply
Motherboard/CPU-board
Measurement boards
(DEWE-ORION, ...)
PCI boards
(USB, FireWire, ...)
USB, FireWire, Ethernet
(on-board)
CPU
RAM
onboard VGA
RS-232
+15V, GND, -15V
+12V, GND, -12V
DC/DC
converter
MDAQ
DAQ-Motherboard
DAQ-Modules
14
Display
First steps
First steps
1
Power-on your system.
3
2
Connect your sensors to the
system.
Run DEWESoft usually
via "Start" >"Programs" >
"Dewetron" > "DEWESoft x.x"
> "DEWESoft x.x"
4
Start recording your data!
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
15
First steps
Notes
16
Main System
Main System
DEWE-2600 series instruments
Portable data acquisition system
Up to 16 channels with isolation
(in conjunction with DEWE-DAQ modules)
Up to 64 channels with differential inputs
(in conjunction with DEWE-MDAQ modules)
System specifications
Standard power supply:
Power supply options:
2600-POW-BAT
Operating temperature:
Operating temperature with
2600 POW-BAT option:
Storage temperature:
Humidity (operating):
�
Input range
100 to 240 VAC input (50/60 Hz)
Battery powered with 18 to 24 VDC input
MDAQ-AAF4-5-BU
�
MDAQ-FILT-10
�
�
�
�
�
�
�
�
�
MDAQ-FILT-5-BE
�
�
�
�
�
�
�
�
�
MDAQ-FILT-5-BU-S1
�
�
�
�
�
�
�
�
�
MDAQ-FILT-5-BU
�
�
�
�
�
�
�
�
�
MDAQ-BASE-10
�
�
�
�
�
�
�
�
�
MDAQ-BASE-5
�
MDAQ-SUB-STG
�
MDAQ-SUB-BRIDGE
�
MDAQ-SUB-ACC-A-x
�
MDAQ-SUB-ACC-x
MDAQ-V-100
�
MDAQ-SUB-V-200
MDAQ-V-10
Channel 0 to 7*
Channel 8 to 15*
Channel 16 to 23*
Channel 24 to 31*
Channel 32 to 39*
Channel 40 to 47*
Channel 48 to 55*
Channel 56 to 63*
MDAQ-DIRECT
DEWE-2600
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
Model
� MPM-842P
� FSP400-60PFN/PLN
For details see next pages!
please select!
� XP-04 with DC-123
0 °C to +50 °C
0 °C to +50 °C when discharging batteries
0 °C to +45 °C when charging batteries
-20 °C to +70 °C
10 % to 80 %, non condensing
5 % to 95 %, rel. humidity
**
Shape
Vibration test
EN 60068-2-6
Frequency range
(exceeds MIL-STD 810F 514.5 Acceleration
procedure I)
Sweep rate
Duration
Test in 3 directions
Vibration test**
Shape
EN 60721-3-2
Frequency range
Class 2M2
Power spectral density
Duration
**
Shape
Shocktests
EN 60068-2-27
Acceleration amplitude
(Exceeds MIL-STD 810F 516.5 Duration
procedure I)
Test in 3 axis, 3 shocks in each axis and direction
Dimensions (W x D x H):
Weight:
*)
approx. 409 x 245 x 291 mm (16.1 x 9.6 x 11.5 in.)
typ. 14 kg (30.8 lbs), depending on configuration
depending on system configuration! For details see next pages.
**)
tested with SSD disc
!
Note: If option 2600-POW-BAT is installed in your system and you don't use it for more than 2
weeks, please remove the batteries and store them separately! Otherwise the batteries will be
discharged completely and may be destroyed!
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
17
Main System
Dimensions*
243,94
3
295
408
* Dimensions in mm
(1 inch = 25.4 mm)
18
401,5
Main System
Connectors
Connector overview:
Typical DEWE-2600 front view
1
1
2
4
3
Typical DEWE-2602 DC version rear view
10
19
9
8 7 6 5
23
20 21
Typical DEWE-2602 AC version rear view
22
10
1 Built in speakers
2 External HDD access
3 USB interface connector
4 Power-on button
5 Ground connector
6 Power supply input connector
(with option 2600-POW-BAT)
7 Power supply for accessories
(12 VDC / 1.5 A)
8 EPAD connector
9 CAN interface connector
10 Digital I/O connector
11 IEEE-1394 (FireWire®) connector
12 PS/2 mouse connector
13 RS-232 interface connector
14 VGA connector
15 PS/2 keyboard connector
16 Ethernet LAN connector
17 Audio device
(LINE IN, MIC, LINE OUT)
18 DVD multi-drive
19 Battery panel
20 Main power switch
21 AC power supply connector
22amera trigger connector
23 Optional counter inputs
11
12
13
14
15
3 16 17 18
Note: The location of the connectors might vary from system to system and depends on configuration
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
19
Main System
Power-on button
The power-on push button has to be used to switch on the system. It only works when the main power switch
is on.
Ground connector
For some kind of measurements, it’s necessary to give the system an additional ground connection.
Power supply input connector
For details see next pages.
Power supply for accessories
To supply your accessories with 12 VDC. Fused with an 1.5 A self-healing fuse.
Pin assginment
1: +12 V, max 1.5 A
2: GND
+
1
2-
Lemo EGG.1B.302
EPAD connector (LEMO)
To connect DEWETRON EPAD modules to the system.
Pin assginment
1: RS-485 A
2
1
2: RS-485 B
3
4
3: +12 V
4: GND
Shield is connected on housing
Lemo EGG.1B.304
CAN connector (optional)
This connector supports the CAN signals of the built-in A/D board. If this board does not support CAN
signals, the connector is not available. For more informations please refere to Appendix-B.
Digital I/O connector
This connector supports digital input and output lines of the built-in A/D board. If this board does not support
digital I/O’s, the connector is not available.The pin assignment is depending on the used A/D board - details
are available in appendix B.
PS/2 mouse / keyboard connector
The mouse / keyboard connector could be used to connect a keyboard or an external PS/2 mouse. The
connector meets standard PS/2 pin assignment.
Ethernet connector
The DEWE-2600 system supports 10/100/1000 BaseT Ethernet with standard RJ45 connector.
Camera trigger connector
The camera trigger connector allows you to connect high speed cameras to your system.
Pin assginment
2
1: TRG
1
3
2: GND
3: n.c.
Lemo EGG.1B.303
20
Main System
Optional counter inputs
The pin assignment of the optional counter input is available in appendix B.
RS-232 interface connector
The RS-232 interface connector (male) is located on the left side of the DEWE-2600. It can be used for
mouse or other peripheral units.
1 2 3 4 5
9-pin SUB-D connector (male)
6 7 8 9
Schematic
VGA connector
Pin assignment
1: DCD (Data Carrier Detector)
2: RD (Received Data)
3: TD (Transmitted Data)
4: DTR (Data Terminal Ready)
5: GND (Ground)
6: DSR (Data Set Ready)
7: RTS (Request To Send)
8: CTS (Clear To Send)
9: RI (Ring Indicator)
The VGA connector offers the possibility to connect a CRT or other standard VGA displays to the system.
5 4 3 2 1
Pin assignment
1: Red video
2: Green video / Sync on green
3: Blue video
4: 15 14 13 12 11
5: 15-pin mini-SUB-D connector (male)
Schematic
6: Red video ground
7: Green video ground
8: Blue video ground
9: 10:Ground
11: Ground
12:Data line
13:H-Sync / HV-Sync
Some systems have a DVI connector instead or additionally to the VGA. 14:V-Sync
15:Clock line
10 9 8 7 6
15-pin mini-SUB-D connector (male)
Schematic
Pin assignment
1:
2:
3:
4:
5:
6:
7:
8:
TDMS-data 2TDMS-data 2+
Shield TDMS-data 2,4
TDMS-data 4TDMS-data 4+
DDC clock
DDC data
Analog: V-Sync
9: TDMS-data 110:TDMS-data 1+
11: Shield TDMS-Daten 1,3
12:TDMS-data 313:TDMS-data 3+
14:+5 volt
15:Ground for +5 volt
16:Hotplug-Detect
17:TDMS-data 018:TDMS-data 0+
19:Shield TDMS-data 0,5
20:TDMS-data 521:TDMS-data 5+
22:Shield TDMS-Takt
23:TDMS-clock+
24:TDMS-clock -
C1:Analog: red
C2:Analog: green
C3:Analog: blue
C4:Analog: H-Sync
C5: Analog: ground
USB interface connectors (Universal Serial Bus)
The USB interface connectors meets standard USB pin assignment.
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
21
Main System
Possible configurations
Function panels
Standard panel for DEWE-2600-CA
DEWE-2600
Options
Analog input - DAQ modules
0.5U-AMPFLEX-POWER-4
0.5 U
0.5U-AMPFLEX-POWER-8
0.5 U
2U
Power supply for PNA-A100
current clamps
Combustion analyzer input
0.5U-AOUT-BNC-2
2U
0.5 U
1U-AOUT-BNC-4
1U
1.5U-ORION-DIO-PANEL-1
1U-AOUT-BNC-8
1.5 U
1U
Analog output
Counter input with digital input
MDAQ panels
DEWE-2601
Options
1.5U-ORION-DIO-PANEL-1
1.5 U
1.5 U
Counter input with digital input
4U
4.5 U
0.5U-AMPFLEX-POWER-4
2U
0.5 U
0.5 U
0.5U-AMPFLEX-POWER-8
0.5 U
Limited use
(no 1.5 U MDAQ panel in this area)
Power supply for PNA-A100
current clamps
2U
0.5U-AOUT-BNC-2
0.5 U
1U-AOUT-BNC-4
Analog input - MDAQ modules
1U
1U-AOUT-BNC-8
1U
Analog output
22
Main System
MDAQ panels
DEWE-2602
Options
1.5U-ORION-DIO-PANEL-1
Analog input - DAQ modules
1.5 U
1.5 U
Counter input with digital input
2U
0.5U-AMPFLEX-POWER-4
2U
0.5 U
0.5U-AMPFLEX-POWER-8
0.5 U
Power supply for PNA-A100
current clamps
2U
0.5U-AOUT-BNC-2
0.5 U
1U-AOUT-BNC-4
Analog input - MDAQ modules
1U
1U-AOUT-BNC-8
1U
Analog output
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
23
Main System
DAQ series modules overview
Module
Bandwidth (BW),
TEDS Filters (LP = lowpass,
HP = highpass)
Isolation (ISO),
Overvoltage
protection (OP)
Input type
Ranges
High voltage
±20, ±50, ±100 V
±200, ±400, ±800, ±1400 V
-
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
ISO: 1.8 kVRMS
High voltage
±10, ±40, ±100 V
±200, ±400, ±1000 V
-
BW: 20/30 kHz
LP: 10, 100 Hz, 1, 3,
20/30 kHz
ISO: 1.5 kVRMS
Voltage, current with external
shunt
±10, ±20, ±50 mV
±100, ±200, ±500 mV
±1, ±2.5, ±5, ±10, ±25, ±50 V
±10, ±20, ±50, ±100, ±200 mV
±500 mV, ±1, ±2.5, ±5, ±10 V
-200° C to 1000° C and
0 to 6.5 kOhm
■
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
ISO: up to
1 kVRMS
OP: 350 VDC
Voltage
Current with external shunt
±0.01, ±0.1, ±1, ±5, ±10, ±50 V
-
BW: 50 kHz
LP: 10, 100 Hz, 1, 10,
50 kHz
ISO: up to
1 kVRMS
OP: ±500 VDC or
300 VRMS
Voltage
±10 V (1:1 input)
-
-
OP: < ±500 V
(jumper
selectable)
DAQP-LA-SC
Current
Note: 5 ARMS continuous
±0.1, 0.3, 1, 3 A
± 10 A peak, ± 30 A peak
max. 5 ARMS contin. current
-
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
ISO: 1.4 kVRMS
DAQP-LA-B
Current
Note: typ. 20 mA application
±2, 6, 20 mA
± 60 mA, 200 mA, 0.6 A
max 0.6 A
-
BW: 300 kHz
LP: 10, 30, 100, 300 Hz
1, 3, 10, 30, 100, 300 kHz
ISO: 1.4 kVRMS
Strain gage, bridge sensors
±1, ±2, ±5, ±10, ±20, ±50 mV/V
(@ 5 VDC)
-
BW: 20 kHz
LP: 10, 100 Hz, 1, 5, 20 kHz
ISO: 350 VDC
OP: ±10 VDC
Potentiometric sensors
Thermocouple via MSI-BR-TH-x
200 Ω - 10 kΩ
full range of TC type
Strain gage, bridge sensors
±0.1, ±0.2, ±0.5, ±1, ±2,
±5, ±10, ±20, ±50, ±100 mV/V
(@ 5 VDC)
BW: 200 kHz
LP: 10, 30, 100, 300 Hz,
1, 3, 10, 30, 100, 200 kHz
OP: ±10 VDC
Potentiometric sensors
Thermocouple via MSI-BR-TH-x
200 Ω - 10 kΩ
full range of TC type
AC bridge, strain gage
Bridge: 0.1 to 1000 mV/V
BW: DC to 2.3 kHz
LP: 10, 30, 100, 300 Hz,
1 kHz
OP: ±10 VDC
High voltage measurement
DAQP-HV
V
DAQP-DMM
V
Voltage & current measurement
DAQP-LV
V
®
ICP via MSI-V-ACC
Pt100, Pt200, Pt500, Pt1000,
Pt2000 and resistance via
MSI-V-RTD
DAQP-V
V
DAQN-AIN
V
Bridge / strain gage and carrier frequency amplifier
DAQP-BRIDGE-A
DAQP-BRIDGE-B
DAQP-CFB
Inductive: 5 to 1000 mV/V
Inductive sensors, LVDT
1)
TEDS support for DAQP-BRIDGE-B revision 2 only
24
■ 1)
-
Voltage: 0.2 to 1000 mVRMS
■ = standard
Main System
Module
Input type
Ranges
Bandwidth (BW),
TEDS Filters (LP = lowpass,
HP = highpass)
Isolation (ISO),
Overvoltage
protection (OP)
Charge / ICP® measurement
®
±50, ±166, ±500 mV, ±1.66, ±5 V
(Gain: 1, 3, 10, 30, 100)
-
BW: 0.5 Hz to 300 kHz
LP: 1, 10, 100, 300 kHz
HP: 0.5 Hz, 5 Hz
-
®
Charge: 5, 50, 500 pC
5000, 50000 pC
ICP®: ±5, ±50, ±500 mV, ±5 V
(0, 20, 40, 60 dB)
-
BW: 0.1 Hz to 50 kHz
LP: 100 Hz, 1, 3, 10, 50 kHz
HP: 0.1 Hz, 1 Hz, 10 Hz
-
±100, ±500, ±2 000,
±10 000, ±40 000,
±200 000, ±1 000 000 pC
-
BW: DC to 100 kHz
LP: 10, 30, 100, 300 Hz,
1, 3, 10, 30, 100 kHz
HP: DC, 0.001 Hz to 0.5 Hz
ISO: 350 VDC
K and J type, various ranges
-
BW: 4 Hz
ISO: 1 kVRMS
Thermoresistors
Pt100, various ranges
-
BW: 10 Hz
-
Frequency
100 Hz, 1, 5, 20, 100, 200 kHz
-
BW: according to range
LP: 100 Hz,
1, 5, 20, 100, 200 kHz
ISO: 350 VDC
Voltage output
1:1 output module with isolation
Input voltage: ±10 V
Output voltage: ±10 V
-
BW: 400 Hz
ISO: 240 VDC
DAQP-ACC-A
ICP sensors
DAQP-CHARGE-A
ICP sensors, charge sensors
Note: selectable integration and
double integration
DAQP-CHARGE-B
Charge sensors
Note: selectable time constant
for static sensors
Temperature measurement
DAQN-THERM-x
Thermocouple
Note: internal CJC
DAQN-RTD-x
Frequency measurement
DAQP-FREQ-A
Voltage output module
DAQN-V-OUT
OUT
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
25
Main System
MDAQ series amplifiers overview
SUB Modules for MDAQ-BASE-x
Module
MDAQ-SUB-STG-D
Connector: DB-9
# CH Input type
8
V
MDAQ-SUB-BRIDGE-D
Connector: DB-9
8
V
MDAQ-SUB-V-200-D
Connector: DB-9
8
V
MDAQ-SUB-V-200-BNC
Connector: BNC
8
14 ranges from ±0.5 to 1000 mV/V
(@ 5 VDC excitation
TEDS
Bandwidth (BW),
Excitation
Highpass filters (HP)
■
BW: 30 kHz
0 to 12 VDC
■
BW: 30 kHz
HP: 0.16 Hz
+15 VDC and
0 to 12 VDC
■
BW: 300 kHz
±15 VDC and
0 to 12 VDC
-
BW: 300 kHz
-
■
BW: 300 kHz
HP: 3.4 Hz
4 / 8 mA
■
BW: 300 kHz
HP: 0.16 Hz
4 / 8 mA
■
BW: 300 kHz
HP: 0.16 Hz, 3.4 Hz
4 / 8 mA
■
BW: 300 kHz
HP: 0.16 Hz, 3.4 Hz
4 / 8 mA
15 ranges from ±2.5 mV to ±10 V
7 ranges from ±0.25 mV to ±10 V
6 ranges from ±10 to ±200 V
full range of TC type
-200 °C to 1000 °C
and 0 to 6.5 kOhm
* Strain-gage (Full-, and half bridge)
for strain gage sensors:
* Voltage up to ±10 V:
* ICP, via MSI-BR-ACC:
* Voltage up to 200 V via MSI-BR-V-200:
* Thermocouple via MSI-BR-TH-x:
* Pt100, Pt200, Pt500, Pt1000, Pt2000
and resistance via MSI-BR-RTD:
14 ranges from ±0.5 to 1000 mV/V
(@ 5 VDC excitation
* Voltage up to ±200 V:
* ICP, via MSI-V-ACC:
* Pt100, Pt200, Pt500, Pt1000, Pt2000
and resistance via MSI-V-RTD:
Note:
for safety reasons, max. 120 V DC or 50 V AC
13 ranges from ±0.125 to ±200 V
7 ranges from ±0.25 mV to ±10 V
-200 °C to 1000 °C
and 0 to 6.5 kOhm
* Voltage up to ±200 V:
13 ranges from ±0.125 to ±200 V
15 ranges from ±2.5 mV to ±10 V
7 ranges from ±0.25 mV to ±10 V
6 ranges from ±10 to ±200 V
full range of TC type
-200 °C to 1000 °C
and 0 to 6.5 kOhm
are allowed at this connector
Note:
for safety reasons, max. 120 V DC or 50 V AC are allowed at this connector
V
MDAQ-SUB-ACC-BNC
Connector: BNC
* Strain-gage (Full-, half and quarterbridge, incl. shunt calibration)
for strain gage application:
* Voltage up to ±10 V:
* ICP via MSI-BR-ACC:
* Voltage up to 200 V via MSI-BR-V-200:
* Thermocouple via MSI-BR-TH-x:
* Pt100, Pt200, Pt500, Pt1000, Pt2000
and resistance via MSI-BR-RTD:
Input ranges
8
* ICP® or voltage up to ±10 V:
8 ranges from ±125 mV to ±10 V
Single-ended or differential input and one highpass filter
3.4 Hz highpass filter for noise and shock response measurement
MDAQ-SUB-ACC-BNC-S1
0,16 Hz for structural and modal analysis, human body vibration measurement
(rest same as MDAQ-SUB-ACC-BNC)
MDAQ-SUB-ACC-A-BNC
Connector: BNC
8
* ICP® or voltage up to ±10 V:
8 ranges from ±125 mV to ±10 V
Single-ended input and two HP filters
0.16 Hz for structural and modal analysis, human body vibration measurement
3.4 Hz for noise and shock response measurement
MDAQ-SUB-ACC-A-MD
Connector: Microdot
8
* ICP® or voltage up to ±10 V:
8 ranges from ±125 mV to ±10 V
Single-ended input, two HP filters and sensor failure detection
0.16 Hz for structural and modal analysis, human body vibration measurement
3.4 Hz for noise and shock response measurement
Option: test signal input for all channels
26
Main System
Filter modules for MDAQ
Module
MDAQ-AAF4-5-BU
# CH
16
Filter characteristics
Butterworth
Cut-off frequencies
100 Hz, 1, 10, 30, 100 kHz, Bypass
Order
th
4
Note:
not possible in all system configurations.
Please contact factory for details.
nd
MDAQ-FILT-5-BU
16
Butterworth
30, 100, 300 Hz, 1, 10 kHz, Bypass
2
MDAQ-FILT-5-BU-S1
16
Butterworth
100 Hz, 1, 10, 30, 100 kHz, Bypass
2
MDAQ-FILT-5-BE
16
Bessel
30, 100, 300 Hz, 1, 10 kHz, Bypass
2
nd
nd
Modular smart interfaces to connect various sensors
Multisensor inputs for MDAQ and DAQP modules
MSI-BR-ACC
MDAQ-SUB-STG-D
MDAQ-SUB-BRIDGE-D
MDAQ-SUB-V-200-D
DAQP-BRIDGE-A *
DAQP-BRIDGE-B
DAQP-LV-D
�
�
-
-
-
-
Isotron (constant current powered) adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector
Excitation current 4 mA at 21 V, High pass filter 1.5 Hz, BNC connector
Bandwidth and ranges are defined by connected amplifier
automatic adapter identification
MSI-V-ACC
-
-
�
-
-
�
Isotron (constant current powered) adapter for DAQP-V-x and MDAQ-SUB-V-200 modules with DB9 connector
Excitation current 4 mA at 21 V, High pass filter 1.5 Hz, BNC connector
Bandwidth and ranges are defined by connected amplifier
automatic adapter identification
MSI-BR-V-200
�
�
-
-
-
-
200 V input adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector
Differential input configuration, BNC connector
Bandwidth and ranges are defined by connected amplifier
automatic adapter identification
MSI-BR-RTD
�
�
-
-
-
-
Pt100, Pt200, Pt500, Pt1000 and Pt2000 adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector
2, 3 and 4 wire connection methods, 5-pin Binder 710 series connector
automatic adapter identification
MSI-V-RTD
-
-
�
-
-
�
Pt100, Pt200, Pt500 and Pt1000 adapter for DAQP-V-x and MDAQ-SUB-V-200 modules with DB9 connector
2, 3 and 4 wire connection methods, 5-pin Binder 710 series connector
automatic adapter identification
MSI-BR-TH-K
MSI-BR-TH-J
MSI-BR-TH-T
�
�
-
�
�
-
isolated TC sensor
isolated TC sensor
any TC sensor
Thermocouple type K / J / T adapter for DAQP-BRIDGE-x and MDAQ-SUB-BRIDGE / -STG modules with DB9 connector
For use with isolated thermocouple sensors only ! (except in combination with DAQP-BRIDGE-A*)
High accuracy cold junction reference measurement, 1 m thermo cable with Mini TC connector
automatic adapter identification
* no automatic MSI identification with DAQP-BRIDGE-A
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
27
Main System
Power supply
AC standard power supply
400 W AC power supply
Input:
Input range:
Input frequency:
Max. input current:
Output:
Output power:
Output voltages:
MPM-842P
100 to 240 VAC (auto selecting)
47 to 63 Hz
8 A (115 VAC)
400 W continuous (450 W peak)
+3.3 V (max. 22 A)
+5 V
(max. 21 A)
+5 Vsb (max. 1.5 A)
+12 V (max. 22 A) -12 V (max. 0.8 A)
AC power supply
AC power switch
400 W AC power supply
Input:
Input range:
Input frequency:
Max. input current:
Output:
Output power:
Output voltages:
AC power switch
AC power supply
AC power supply out
28
FSP400-60PFN/PLN
100 to 240 VAC (auto selecting)
50 to 60 Hz
10 A (115 VAC) or 5 A (230 VAC)
400 W
+3.3 V
+5 V
+5 Vsb
+12 V
(max. 235 W @ +3.3 V and +5 V)
(max. 28 A)
(max. 40 A) -5 V (max 0.3 A)
(max. 2 A)
(max. 15 A) -12 V (max. 0.8 A)
Main System
Internal battery power supply: option DEWE-2600-POW-BAT
320 W DC power supply
with XP-04 battery management
Input:
Input range:
Input frequency:
Max. input current:
18 to 24 VDC (nom. 18 VDC)
DC
12 A
Output:
Output power:
Output voltages:
DC-023-12V option:
320 W
+3.3 V
+5 V
+12 V
with XP-04 battery management (only single DC-DC)
(max. 10 A)
(max. 10 A)
(max. 12 A)
-12 V
(max. 0.25A)
Power supply pin assignment:
+
If option 2600-POW-BAT is installed, there are 3 slots for hotswappable smart batteries available in the system. Standard
shipment includes 2 smart batteries, more can be ordered
additionally (option BAT-95WH).
-
Connector type
2-pin. male
LEMO EGJ.2B.302
Note: If the system is powered by batteries, please take care that there are at least 2 batteries installed! In some special applications 3 batteries are necessary! (Hot swap of the batteries not possible)
External AC/DC power supply (standard accessory inkluded with option 2600-POW-BAT)
AC/DC power supply
Input:
Input voltage:
Input frequency:
Input current (typ.):
Inrush current (typ.):
Leakage current:
P.F.C. (typ.):
Output:
Output voltage:
Min. load:
Rated load (free / fan):
Output tolerance:
Ripple & Noise (max.):
Efficiency (typ.):
Output connector:
DEWE-POW-24-350
90 to 264 VAC / 127 to 370 VDC universal input
47 to 63 Hz
2 A @ 230 VAC / 4 A @ 115 VAC
44 A @ 230 VAC / 22 A @ 115 VAC
<2 mA @ 240 VAC
0.95 @ 230 VAC / 0.98 @ 115 VAC
24 V
0A
12.5 A / 14.6 A
±2 %
150 mV
88 %
Banana jacks and LEMO EGG.2B.302
Protection:
Overload:
Over voltage:
Over temperature:
Short curcuit:
105 % to 130 % constant current limiting, auto recovery
26.7 to 32.4 V; Hiccup mode, auto recovery after fault has been removed
> 80°C ±5°C detect on heat sink of power transistor Shutdown, auto recovery after temp. has fallen
Yes
Setup time:
<2000ms @ 230VAC / 4000ms @ 115VAC
Rise time:
Holdup time:
Withstand voltage:
Isolation resistance:
<100ms @ 230 VAC / 100ms @ 115 VAC
16ms @ 230 VAC / 16ms @ 115 VAC
I/P-O/P:3 KVAC, I/P-FG:1.5 KVAC, O/P-FG:0.5 KVAC / 1 minute
I/P-O/P, I/P-FG, O/P-FG: 500 VDC / 100 MOhm
Switching frequency:
100 kHz
Temperature:
Operating:
Derating:
Storage:
-10 to 65°C
45 to 60°C: 2 %/°C (3.5 & 5 V: 40 to 65°C: 2 %/°C)
-40 to 85°C
Humidity:
Operating:
Storage:
20 to 90 % RH
10 to 95 % RH (non condensing)
M.T.B.F.:
> 106 K hours ( according to MIL-HDBK-217F at 25°C environment)
Safety:
Approved: UL 60950-1 / TÜV EN60950-1
EMC:
EMI
EMS
EN55022 Class B / EN61000-3-2,3
EN61000-4-2,3,4,5,6,8,11 / ENV50204
Dimensions (W x D x H):
248 x 106 x 62 mm (9.8 x 4.2 x 2.4 in.)
Weight:
1.7 kg (3.7 lbs)
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
29
Main System
DEWE-2600 with option POW-BAT and external AC/DC power supply
External AC Power supply 24
+
C
VD
-
Lemo EGG.2B.302
DEWE-POW-24-350
90 to 260 VAC IN
Smart battery packs
30
Smart battery packs are equipped with an integrated
circuit which stores information (such as manufacturer,
serial number, production date etc.) and monitors the
current battery status in terms of discharge rate, predicted
remaining capacity, temperature, voltage etc. The battery
packs, supplied with every battery powered DEWETRON
system, are even capable of displaying their charge state
without a separate device. With the push of a button,
a LED display on the battery pack shows the current
charge state in 25% steps. An intelligent battery controller,
integrated in our DEWETRON systems, takes care of
the charging and discharging process in order to ensure
maximum battery performance and life time.
Main System
External battery charger (optional)
External battery charger
CH5000A/E/U
Power supply:
Input voltage:
Input current:
Mains Cord:
Dimensions (WxDxH):
Weight:
Mating connector:
90 to 260 VAC, 24V
2.5 A
CH5000E - 220 V European 2-pin connector with ground recess
180 mm x 92 mm x 58 mm
ca. 250 g
5-blade standard battery connector
From time to time, due to the aging process of the batteries, it is necessary to recalibrate the battery in order
to retain the accuracy and reliability of the fuel gauge. This can be archieved with an external battery charger
(BAT-CHARGER) which is optionally available. Another advantage of the BAT-CHARGER is that additional
batteries can be recharged without being in the measurement unit. This allows the measurement unit to run
non-stop without being connected to the power net, thanks to the hot-swap capability of the battery packs.
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
31
Main System
External DC/DC power supply
(recommended option if system is configured with 2600 POW-BAT power supply)
DC/DC power supply
Input:
Input voltage:
Max. input current:
Input connector:
10 to 36 VDC (the input is protected against wrong polarity
36 A @ 10 VDC input voltage (15 A @ 24 VDC)
2-pin LEMO connector male, type: EGJ.3B.302
Output:
Output voltages:
Output power:
Output current:
Output connector:
24 V
300 W
12.5 A
2-pin LEMO connector female, type: EGG.2B.302
Operating temperature:
Derating above 45 °C:
-20 °C to 60 °C
8 Watt/°C
Isolation voltage:
DEWE-DCDC-24-300-ISO
500 VDC
Status LED:
Dimensions: (W x D x H):
Weight:
Green LED indicates an output voltage > 21 VDC
approx. 219 x 122 x 50 mm (8.6 x 4.8 x 2 in.)
1.3 kg (2.9 lbs)
Power on sequence:
First: Connect the system and the DCDC! Followed by the DCDC and the power supply connection.
As an option the DEWE-2600 is shipped with the DEWE-DCDC-24-300-ISO. This power supply serves
galvanic isolated voltage with a wide input range from 10 to 36 VDC. The output voltage is fixed with 24 VDC
with a maximum output power of 300 W.
Depending on the configuration, the DEWE-2600 takes usually not more than 150 W. The typical power
consumption is just around 70 W. However, if the batteries are empty the input current can go up to 12
Ampere which is an equivalent power consumption of 280 Watt! If the unit is supplied from a typical board
supply of 12 V it needs an input current of 28 A!
If this high power is not available in the board supply please operate the DEWE-2600 without or with charged
batteries.
Dimensions*
219
* Dimensions in mm
(1 inch = 25.4 mm)
Input connector
1+
2-
Lemo EGJ.3B.302
32
122
2
Output connector
Pin assginment
1: 10 .. 36 VDC input
2: GND
146
136
20,3
15,7
5
16 0
Pin assginment
1: 24 VDC output
2: GND
1+
2-
Lemo EGG.2B.302
49,8
Main System
Maintenance
External HDD access for easy service
If the system harddisk drive gets damaged, an external HDD access for easy service is available. Pull out the
access bay for removing/changing the system harddisk drive.
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
33
Main System
Notes
34
Software
DEWESoft
DEWESoft
DEWESoft turns your hardware into a powerful data acquisition system. Our award-winning data acquisition package is
second to none when it comes to both pure recording power and ease of use. Normally this is a difficult balancing act:
providing lots of capability and performance, without making the user interface hard to learn. But we‘ve done it!
DEWESoft is the solution to acquire signals synchronous from different sources, display and store
them together and offer the data for post analysis.
Measure
Scope
Recorder
FFT
Video
Export
Print
One of the most powerful and yet
easy to use aspect of DEWESoft is
the creation of displays. Of course,
a few standard displays are builtin for you, like screens for these
instruments:
Recorder (vertical and horizontal recorder screens are included)
Oscilloscope (free run, triggered, with 2D and 3D waterfall displays, and more)
FFT (with selectable axes, line length, window, type, averaging, overlapping, weighting, and more)
Video – Scalable video window with an assignable recorder graph below
GPS – Track with background map, plus speed, distance, heading, etc.
Analyze Mode
REPLAY, EXPORT, SHARE DATA!
Here you can replay any captured data file, zoom in with the
recorder graph cursors, make measurements, print in full color
to any Windows printer, and export the data to a wide variety
of formats compatible with today‘s popular analysis software
packages, like Flexpro, Matlab, Excel, and many more.
You can even export a AVI video file from your recorded data to
create “moving documentation.“ NO LICENSE is needed to use
DEWESoft in the ANALYZE mode, so you can install the software
on all your computers, or even distrbute it to your customers, and
they can install it. In this way, all of your colleagues and customers
can replay your data files and do all of the functions that you can –
just give them the data file to open.
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
35
DEWESoft
Notes
36
A/D & D/A Conversion
A/D & D/A Conversion
A/D Conversion
Detailed information about the A/D card are not included in this manual.
For detailed information see the manufacturer’s A/D card manual.
D/A Conversion
Detailed information about the D/A card are not included in this manual.
For detailed information see the manufacturer’s D/A card manual.
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
A1
A/D & D/A Conversion
Notes
A2
Internal Wiring
Internal Wiring
16 slot DEWE-MOTHERBOARD DAQ-MOTH-16-DE-x
Rear view
W7
5 = 5 V output; 330 kHz filter
10 = 10 V output; 330 kHz filter
GND
+15 V ORION
-15 V ORION
W1
W10
CH 0
Front view
CH 1
W11
16 channels single ended
analog output
(output resistance 15 Ohm)
Please find the pin-assignment
on the next page!
W8
CH 2
CH 3
5 V ORION
Ext. CLK
Ext. TRIG
DGND ORION
Ext. CLK 2 OUT
Ext. CLK 1 OUT (CAMERA TRIGGER)
W9
CH 4
CH 5
DGND ORION
W5
CH 6
W1
16x GND
16 x analog OUT (resistance 50 Ohm)
GND
W2
W3
W4
W5
W6
W7
W8
W9
Terminate RS-485
Connect GND to GNDP
Connect +12 V to +V (pin 6)
Terminate RS-485
Connect chassis to GND
Connect chassis to GND
Connect chassis to GND
Activate ORION RS-485 (A)
Activate ORION RS-485 (B)
CH 7
CH 8
CH 9
CH 10
CH 11
W10
W11
Activate analog output 0 on CH 14
Activate analog output 1 on CH 15
Note: If you connect signals to these
contacts you have to open the solder
jumpers W10 and W11 first!
CH 12
CH 13
CH 14
Connection to CH14 (pin 7)
Connection to CH15 (pin 7)
Indicator
+9 V
-9 V
CH 15
1 2 3 4 5
W4
+V
+12 V
GNDP
-12 V
-V
GNDC
GNDC
TX
RX
1
2
3
4
5
6
7
8
9
RS-232
9-pin SUB-D pin assignment:
A (RS-485)
GNDC
B (RS-485)
GNDP
+V
+12 V
-12 V
-V
RS-485
RS-485
W3
6 7 8 9
GND
POWER
W2
W6
POWER
DM
DP
GNDC
RX
TX
GNDC
B
B
A
A
USB
RES
GND
Module input (±5 V)
RS-485 (A)
RS-485 (B)
GND
+9 V power supply
+12 V power (default) /
+V sensor supply
Module output
(from A/D board)
-V sensor supply
-9 V power supply
The 16 slot DEWE-MOTHERBOARD receives the ±12 VDC power supply via a DC/DC converter from the
internal power supply.
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
B1
Internal Wiring
Analog output connector pin-assignment
Connector for DEWE-ORION-1616 cards
+15 V
AGND
AGND
AGND
AGND
AGND
AGND
AGND
AGND
AGND
AISENSE2
AGND
AGND
AGND
AGND
AGND
AGND
AGND
AISENSE1
AGND
DI8/DO0
DI9/DO1
DI10/DO2
DI11/DO3
DI12/DO4
DI13/DO5
DI14/DO6
DI15/DO7
+5 V
DGND
DGND
+5 V
DGND
DGND
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
Connector for DEWE-ORION-1624 cards
-15 V
AGND
AGND
CH15+
CH14+
CH13+
CH12+
CH11+
CH10+
CH9+
CH8+
CH7+
CH6+
CH5+
CH4+
CH3+
CH2+
CH1+
CH0+
AGND
DI0/Source(0)
DI1/Gate(0)
DI2/AUX_U_D(0)
DI3/Source(1)
DI4/Gate(1)
DI5/AUX_U_D(1)
RS-485A
RS-485B
DI 6
DI 7
EXT_CLK
EXT_Trigger
EXT_CLK1
EXT_CLK2
+15V
AGND
AGND
CH. 15CH. 14CH. 13CH. 12CH. 11CH. 10CH. 9CH. 8CH. 7CH. 6CH. 5CH. 4CH. 3CH. 2CH. 1CH. 0AGND
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
+5 V
DGND
DGND
+5 V
DGND
DGND
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
-15 V
AGND
AGND
CH. 15+
CH. 14+
CH. 13+
CH. 12+
CH. 11+
CH. 10+
CH. 9+
CH. 8+
CH. 7+
CH. 6+
CH. 5+
CH. 4+
CH. 3+
CH. 2+
CH. 1+
CH. 0+
AGND
NC.
NC.
NC.
NC.
NC.
NC.
RES.*
RES.*
RES.*
RES.*
RES.*
EXT-TRIGGER
SAMPLE CLOCK
NC.
* DONT CONNECT
68-pin high density connector
68-pin high density connector
16 slot DEWE-MOTHERBOARD DAQ-MOTH-16-NI-x-U
5 = 5 V output; 330 kHz filter
10 = 10 V output; 330 kHz filter
Connector for National InstrumentsTM A/D cards
DGND
DGND
PFI 8/P2.0
PFI 7/P1.7
PFI 15/P2.7
PFI 13/P2.5
PFI 4/P1.4
PFI 3/P1.3
PFI 2/P1.2
DGND
PFI 10/P2.2
PFI 11/P2.3
P0.3
P0.7
P0.2
DGND
P0.5
P0.0
DGND
AO GND
AO GND
AI GND
AI 7
AI 14
AI GND
AI 5
AI 12
AI Sense
AI 11
AI GND
AI 2
AI 9
AI GND
AI 0
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
PFI 14/P2.6
PFI 112/P2.4
PFI 9/P2.1
DGND
PFI 6/P1.6
PFI 5/P1.5
DGND
+5 V
DGND
PFI 1/P1.1
PFI 0/P1.0
DGND
DGND
+5 V
DGND
P0.6
P0.1
DGND
P0.4
APFI 0
AO 1
AO 0
AI 15
AI GND
AI 6
AI 13
AI GND
AI 4
AI GND
AI 3
AI 10
AI GND
AI 1
AI 8
68-pin high density connector
B2
USB interface on-board
Rear view
W7
W1
DGND
16 channels single ended
analog output
(output resistance 15 Ohm)
Please find the pin-assignment
on the next page!
Analog OUT Ch. 1
Analog OUT Ch. 0
W1
DGND
GND
W2
W3
W4
W5
W6
W7
Terminate RS-485
Connect GND to GNDP
Connect +12 V to +V (pin 6)
Terminate RS-485
Connect chassis to GND
Connect chassis to GND
Connect chassis to GND
Internal Wiring
Please find information about the MDAQ amplifiers in the attached MDAQ-INT series modules manual. The
latest version of the manual can be downloaded from:
http://www.dewetron.com/download/index.php?search=MDAQ&catkey=manuals-amplifiers
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
B3
Internal Wiring
Notes
B4
CE-Certificate of conformity
Manufacturer:
DEWETRON Elektronische Messgeraete Ges.m.b.H.
Address: Parkring 4
A-8074 Graz-Grambach Austria
Tel.: +43 316 3070 0
Fax: +43 316 3070 90
e-mail: [email protected]
http://www.dewetron.com
DEWE-2600
Name of product:
Kind of product:
Portable data acquisition system
The product meets the regulations of the following EC-directives:
73/23/EEC
"Directive on the approximation of the laws of the Member States relating to
electrical equipment designed for use within certain voltage limits amended by
the directive 93/68/EEC"
89/336/EEC
"Directive on the approximation of the laws of the Member States relating to
electromagnetic compatibility amended by the directives 91/263/EEC, 92/31/
EEC, 93/68/EEC and 93/97/EEC
The accordance is proved by the observance of the following standards:
L
V
E
M
C
Safety
IEC/EN 61010-1:1992/93
IEC/EN 61010-2-031
IEC 61010-1:1992/300 V CATIII Pol. D. 2
IEC 1010-2-031
Emissions
EN 61000-6-4
EN 55011 Class B
Immunity
EN 61000-6-2
Group standard
Graz, October 14, 2008
Place / Date of the CE-marking
Dipl.-Ing. Roland Jeutter / Managing director
DE-M081201E • DEWE-2600 • Technical Reference Manual • Printing version 1.0.2 • June 03, 2009
C1
Notes
C2
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement