PEC-1PEC-1
HATCHERY VENTILATION CONTROL
Varifan
®
FAN
PRESSURE
APPROUVÉ
FAN SPEED
ROOM
ACTUAL
SET
MINIMUM
SELECT
-
+
ADJUST
Varifan
STATIC PRESSURE SENSOR
PRESSURE EQUALIZATION
CONTROL
SPS-1
PEC-1
A
FEATURES:
SPECIFICATIONS:
• Maintains static pressure at 0 or set value
by changing fan speed
• Digital static pressure display
• Remote solid state pressure transmitter
• Adjustable minimum fan speed
• Selectable control sensitivity
• Can be use in exhaust or intake mode
• No calibration required
Power Supply: 115 or 23v 50/60Hz
Pressure Range: -120 to +120 inches WC
Output Capacity: 15 Amp, slow blow fuse
Operation Temperature Range: 32 to 100°F
B
®
OPERATION AND INSTALLATION
INSTRUCTIONS
INSTALLATION:
OPERATION:
Two settings on the display are available. The minimum fan
speed can be set to match the idle capability of the fan
controlled by the PEC-1 control. The desired room static
pressure is set to establish the control logic for pressure
control.
The first LED "NEG" on the display lights to indicate a
negative pressure reading or setting. The pressure display
is divided by 1000, for example, if the display indicates 080
and the led NEG is lit , the real value is -0.080 IN WC The fan
speed will display as a percentage.
As the control fan speeds up and slows down to
compensate for changes in room pressure, the actual fan
speed as a percentage can be displayed. Changing the
desired room static pressure will also cause the fan to
change speed to adjust for the different pressure settings.
DIP switches settings:
DIP #1: Not used
DIP #2: ON - Exhaust mode
Increases output when pressure decreases
SPS-1 Static Pressure Sensor
The SPS-1 static pressure sensor can be installed up to 500
feet from the PEC-1 control unit. A three-wire cable of 22
AWG conductors is used to connect the transmitter to the
controller unit. The transmitter box can be located on either
an inside wall or an outside wall, or even the ceiling if
necessary. If the transmitter is mounted outside, it must be in
a protected location so that wind and weather do not disturb
the transmitter air inlet. If the transmitter is mounted on the
inside of the building, the flexible vinyl tube that would be
connected to the exterior probe inlet must also be in a
protected location on the outside of the building.
To mount the transmitter box, remove the four screws that
join the top and bottom halves of the box, then use wood
screws through the holes in the base of the unit to mount the
box to an appropriate surface. Ensure that the wiring is
correct then fasten the top of the unit to the base with the four
screws previously removed from the housing. Make sure
that the tubing is not bent sharply which could interfere with
the pressure sensing function. Do not cut or pinch the tubing.
OFF - Intake mode
PEC-1 Control
Decreases output when pressure decreases
DIP #3: Sensor response timer; ON = Fast, OFF = Slow
DIP #4: Output response timer; ON = Fast, OFF = Slow
PARAMETERS
DESCRIPTION
The PEC-1 control unit should be installed where most
practical for operation. Electrical power corresponding to the
type of fan to be used is wired into the control. Verify that the
correct voltage is selected inside the control unit to match the
line voltage. Make sure that appropriate wiring codes are
used to determine wiring type and size. The output to the fan
is wired from the control unit so as to be able to control the
RANGE
INCREMENTS
REMARKS
-100 to +100”H2O
001
Setting
-120 to +120”H2O
001
Reading
PRESSURE ÷ 1000
Set
Room
Sets desired
Static Pressure
Indicates
Room Static Pressure
Actual
Indicates Fan Speed
16 to 100%
2%
Reading
Minimum
Sets
Minimum Fan Speed
16 to 100%
2%
Setting
Vostermans Ventilation Inc.
2439 South Main St.
Bloomington, IL. 61704
Tel. 309-827-9798
Fax 309-829-1993
[email protected]
www.vostermans.com
Mexico Office
Queretaro, Qro.
Cell 52 442 200 9507
Tel. 52 442 213 9384
Fax 52 442 213 9384
[email protected]
Ventilation
Ventilation parts
H:/LITERATURE/CATALOG/PEC-1
FAN SPEED
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement