GE-IP Control Systems Solutions Catalog

GE-IP Control Systems Solutions Catalog
GE Intelligent Platforms
Control Systems Solutions Catalog
GE Intelligent Platforms
Information Centers
Headquarters:
1 800 433 2682
1 800 322 3616
1 434 978 5100
Control Systems
Solutions Catalog
Enabling improved performance, greater
uptime and lower total cost of ownership
Additional Resources
For more information, please visit the
GE Intelligent Platforms web site at:
www.ge-ip.com­
imagination at work
GFA-406H
GFA-406H
Global Regional phone numbers
are available on our web site
www.ge-ip.com
©2012 GE Intelligent Platforms, Inc. All Rights Reserved.
*Trademark of GE Intelligent Platforms, Inc.
All other brands or names are property of their respective holders.
GE
Intelligent Platforms
imagination at work
Control Systems Solutions Catalog
Table of Contents
Table of Contents
Section 1: Programmable Controllers
PACSystems* RX7i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3
I/O Interface Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.81
CPUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4
Communications Module. . . . . . . . . . . . . . . . . . . . . . . . . . . 1.82
Racks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.6
Accessories and Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.83
Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.7
Series 90-30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.84
I/O Interface Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.8
CPUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.85
Communications Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . 1.9
Baseplates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.88
Accessories and Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.10
Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.89
PACSystems RX3i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.11
Discrete I/O Modules (Input) . . . . . . . . . . . . . . . . . . . . . . . . 1.91
CPUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.12
Analog I/O Modules (Input) . . . . . . . . . . . . . . . . . . . . . . . . . 1.94
Baseplates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.15
Discrete I/O Modules (Output). . . . . . . . . . . . . . . . . . . . . . . 1.96
Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.16
Analog I/O Modules (Output). . . . . . . . . . . . . . . . . . . . . . . 1.101
Discrete Input Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.19
Millivolt I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.103
Analog Input Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.22
RTD I/O Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.104
Discrete Output Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . 1.27
Strain Gage I/O Modules . . . . . . . . . . . . . . . . . . . . . . . . . . 1.105
Analog Output Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.32
Temperature Control Modules . . . . . . . . . . . . . . . . . . . . . 1.106
Analog Mixed Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.36
Thermocouple I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . 1.107
Millivolt I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.37
Network and Distributed I/O Systems. . . . . . . . . . . . . . 1.109
RTD I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.39
Serial Communications Modules. . . . . . . . . . . . . . . . . . . 1.112
Strain Gage I/O Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.41
Power Measurement Modules . . . . . . . . . . . . . . . . . . . . . 1.113
Temperature Control Modules . . . . . . . . . . . . . . . . . . . . . . 1.43
Pneumatic Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.114
Thermocouple I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . 1.44
Programmable Coprocessor Modules. . . . . . . . . . . . . . 1.115
Resistive I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.47
Motion Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.116
Network and Distributed I/O Systems. . . . . . . . . . . . . . . 1.48
Remote Expansion Modules . . . . . . . . . . . . . . . . . . . . . . . 1.118
Co-Processor and Serial
Communications Modules. . . . . . . . . . . . . . . . . . . . . . . . . . 1.50
Portable Program Download Device (PPDD) . . . . . . . . 1.119
Accessories; Cables; Terminal Blocks. . . . . . . . . . . . . . . 1.121
Motion Control (High Speed Counting). . . . . . . . . . . . . . . 1.51
Configuration Guidelines; Typical Applications. . . . . . 1.123
PACMotion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.52
Motion Control (Servo Control). . . . . . . . . . . . . . . . . . . . . . 1.54
α and βi Series Servo Amplifiers. . . . . . . . . . . . . . . . . . . 1.124
VersaMotion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.125
Power Measurement Modules . . . . . . . . . . . . . . . . . . . . . . 1.55
VersaMax* Nano and Micro . . . . . . . . . . . . . . . . . . . . . . . . 1.134
Pneumatic Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.56
Nano PLCs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.136
Expansion Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.57
Micro PLCs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.137
Accessories; Terminal Blocks; Cables; Kits . . . . . . . . . . . 1.58
Discrete Expansion Selection Guide. . . . . . . . . . . . . . . . 1.145
Configuration Guidelines; Typical Application. . . . . . . . 1.63
α and βi Series Servo Amplifiers. . . . . . . . . . . . . . . . . . . . 1.66
Discrete Expansion Units. . . . . . . . . . . . . . . . . . . . . . . . . . 1.146
Analog Expansion Selection Guide. . . . . . . . . . . . . . . . . 1.152
Analog Expansion Units . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.153
VersaMotion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.67
Series 90*-70 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.76
Micro Motion Expansion Units . . . . . . . . . . . . . . . . . . . . . 1.156
CPU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.77
DataPanels Operator Interfaces . . . . . . . . . . . . . . . . . . . 1.157
Racks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.78
Communications Options. . . . . . . . . . . . . . . . . . . . . . . . . . 1.158
Portable Program Download Device (PPDD) . . . . . . . . 1.160
Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.80
©2012 GE Intelligent Platforms. All Rights Reserved. *Trademark of GE Intelligent Platforms. All other brands or names are property of their respective holders.
www.ge-ip.com
05.12 GFA-406H
GE Intelligent Platforms Control Systems Solutions
1
Table Of Contents
Control Systems Solutions Catalog
Accessories; Power Supplies; Cables . . . . . . . . . . . . . . . 1.162
Analog Output Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.45
Starter Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.163
Analog Mixed Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.46
Configuration Guidelines; Typical Applications. . . . . . 1.164
RTD and Thermocouple Modules. . . . . . . . . . . . . . . . . . . . 3.47
VersaMotion Servo Motors and Amplifiers. . . . . . . . . . 1.166
High Speed Counter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.48
Durus* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.174
PowerTRAC Monitoring Module . . . . . . . . . . . . . . . . . . . . . 3.49
AC Models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.175
Accessories, Cables, Hand Held Monitor. . . . . . . . . . . . . 3.50
DC Models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.177
Configuration Guidelines; Typical Applications. . . . . . . 3.51
Discrete Expansion Units. . . . . . . . . . . . . . . . . . . . . . . . . . 1.181
VersaPoint* and VersaSafe I/O. . . . . . . . . . . . . . . . . . . . . . . 3.53
Analog Expansion Units . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.182
Network Interface Modules. . . . . . . . . . . . . . . . . . . . . . . . . 3.54
Communications Options. . . . . . . . . . . . . . . . . . . . . . . . . . 1.183
Power Terminals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.55
Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.184
Segment Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.56
Accessories; Starter Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . 1.185
Discrete Input Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.57
Configuration Guidelines; Typical Applications. . . . . . 1.186
Discrete Output Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . 3.58
Analog Input Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.60
Section 2: Process Control Systems
Analog Output Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.61
Proficy* Process Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3
Functional Safety Modules . . . . . . . . . . . . . . . . . . . . . . . . . 3.62
Proficy Process Systems Overview. . . . . . . . . . . . . . . . . . . 2.3
Motion Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.63
Product Selection Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6
Motor Starter Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.64
Serial Communications Modules. . . . . . . . . . . . . . . . . . . . 3.65
Section 3: Industrial I/O
Accessories and Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.66
VersaMax I/O. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3
Configuration Guidelines; Typical Applications. . . . . . . 3.67
CPUs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4
VersaMax IP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.68
Carriers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5
Stand Alone Input and Output Modules . . . . . . . . . . . . . 3.69
I/O Interposing Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.8
VersaMax IP Modular. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.70
Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.10
Accessories and Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.72
Discrete Mixed I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . 3.12
Configuration Guidelines; Typical Applications. . . . . . . 3.73
Discrete Input Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.16
RSTi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.74
Discrete Output Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . 3.22
Network Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.75
Analog Input Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.25
Network Interfaces with Built-in I/O. . . . . . . . . . . . . . . . . 3.77
Analog Output Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.27
Discrete I/O Modules (Input) . . . . . . . . . . . . . . . . . . . . . . . . 3.88
Analog Mixed Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.29
Analog I/O Modules (Input) . . . . . . . . . . . . . . . . . . . . . . . . . 3.91
RTD and Thermocouple Modules. . . . . . . . . . . . . . . . . . . . 3.30
Discrete I/O Modules (Output). . . . . . . . . . . . . . . . . . . . . . . 3.94
Speciality Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.31
Analog I/O Modules (Output). . . . . . . . . . . . . . . . . . . . . . . . 3.99
Expansion Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.32
RTD Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.102
Remote I/O Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.33
Thermocouple Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.103
Network Interface Modules. . . . . . . . . . . . . . . . . . . . . . . . . 3.35
Serial Communications Modules. . . . . . . . . . . . . . . . . . . 3.104
Serial Communications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.36
High Speed Counting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.106
Accessories, Cables, Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.37
Motion Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.108
Configuration Guidelines; Typical Applications. . . . . . . 3.38
Power Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.110
I/O. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.40
Expansion Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.113
AC Discrete I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.41
Configuration Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.114
DC Discrete I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.42
Accessories and Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.116
Analog Input Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.44
Typical Application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.117
Genius*
*Trademark of GE Intelligent Platforms. All other brands or names are property of their respective holders.
2
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Control Systems Solutions Catalog
Table of Contents
Section 4: Operator Interfaces
Section 7: Services
QuickPanel*
Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3
GE Intelligent Platforms Services Overview. . . . . . . . . . . 7.3
Controllers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4
Basic Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.3
Communication Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.7
GlobalCare* Complete Support. . . . . . . . . . . . . . . . . . . . . . . 7.4
Starter Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.8
Training Services. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.5
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.9
GE Service on Demand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.6
QuickPanel Control Europe, Middle East and Africa. . . . . . . . . . . . . . . . . . . . . . 4.10
Warranty Policy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.7
Controllers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.11
Section 8: Appendix
Communication Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.13
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.14
QuickPanel View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.15
Operator Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.16
Starter Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.23
Communication Hardware and Accessories. . . . . . . . 4.26
Agency Approvals and Certifications. . . . . . . . . . . . . . . . . . . . 8.1
Section 9: Index
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.1
QuickPanel View Europe, Middle East and Africa. . . . . . . . . . . . . . . . . . . . . . 4.27
Operator Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.28
Communication Hardware and Accessories. . . . . . . . 4.33
Section 5: Motion Control Systems
Motion Controllers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3
PACMotion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3
Servo Amplifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.17
VersaMotion Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.18
αi and βi Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.36
Servo Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.51
αi Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.53
βi Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.65
Motion Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.83
Servo Sizing Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.83
Section 6: Software
Proficy Machine Edition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.3
Proficy Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.3
Proficy Machine Edition Components . . . . . . . . . . . . . . . . 6.3
Proficy Logic Developer-PLC:
A Superior Set of PLC Programming Tools. . . . . . . . . . . . 6.4
Product Selection Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.5
*Trademark of GE Intelligent Platforms. All other brands or names are property of their respective holders.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3
Table Of Contents
4
GE Intelligent Platforms Control Systems Solutions
Control Systems Solutions Catalog
www.ge-ip.com
Control Systems Solutions Catalog
Overview
We’re leveraging the future
to give you an edge today.
GE Intelligent Platforms’ Control & Communication Systems (CCS)
business unit is at the leading edge of developing innovative
high-performance platforms that leverage a myriad of enabling
technologies so that industrial and infrastructure customers can
achieve strategic market advantage and lower total cost
of ownership.
In 1879, GE founder Thomas Alva Edison developed
the working prototype of the incandescent light
bulb that transformed the world from a time of
dangerous and inefficient gaslights to safe and
efficient electric light. The technology transformed
cities and home, and allowed businesses to
operate more efficiently than ever before.
Today, we stand at a no less auspicious moment in
history as control and communication technologies
promise to take industry and utilities to unprecedented levels of performance and risk-avoidance.
With a modern analogue no less striking than the
switch from typewriters to computers, business
concerns in manufacturing, water and wastewater
treatment, power generation, telecommunications,
mining, oil & gas production, refining and distribution, and those industries and institutions with a
critical need for uninterrupted power have the
opportunity to revolutionize their processes
and operations.
www.ge-ip.com
In developing solutions that will carry our customers well into the
future, we sought to combine our rich history of rugged embedded
computing and control systems with the leading high-speed, open
industrial communications network and a robust line of I/O options
to provide control system platforms that are truly differentiated.
High-performance redundancy in controllers and I/O provides
greater productivity and uptime for critical systems. With the
emergence of online collaboration and social networking sites, we
are launching a cloud-based open collaboration environment for
automation application creation, deployment and maintenance
while delivering secure protection of invaluable enterprise-wide
digital assets. And we carry forward GE’s heritage of critical
component lifecycle management by engineering our products
with the stated goal of minimal disruption during technology
refreshes and end-of-lifecycle conversions.
Our cloud-based solutions provide
new opportunities
GE Intelligent Platforms Control Systems Solutions
5
Overview
Control Systems Solutions Catalog
GE Intelligent Platforms brings three distinct value propositions
to its Control & Communications Systems customers:
Improved performance – We provide innovative CPUs that leverage our expertise in
rugged embedded computing and controls products. These CPUs are then connected
to the leading open industrial network technology and facilitated with a complete line of
I/O options.
Water
Steam cycle
Well-to-tank
Packaging &
assembly
Mission critical
Telecommunications
Increased uptime – Our high-performance redundancy in controllers and I/O provides
crucial risk reduction that is easily implemented and scaled to meet demand.
Lower Total Cost of Ownership – By embracing game-changing cloud-based data
storage technologies, we provide the option of eliminating software implementation
and maintenance. This secure option not only protects critical enterprise data,
but also facilitates technology collaboration.
We further strive to improve the customer experience by offering pre-engineered
Control & Communications Systems solutions for specific market segments.
These solutions, which employ proven architectures for each application type,
leverage GE’s unparalleled expertise in targeted industrial arenas to provide
industry-specific control algorithms and strategies that quickly optimize the
performance of processes and operations in:
In addition, GE’s lifecycle management service is available to further minimize control
platform risk. Because of our close relationships with key technology providers, we can
design control and communication platforms that meet stated performance and cost
benchmarks, then monitor the availability of critical components through the planned
life of the control platform. When crucial components are nearing the end of their
production run, we can help customers decide whether to purchase and stockpile parts
while they are still available or modify their plans for a scheduled technology refresh.
GE Intelligent Platforms, like its founding father did in his day, stands at the leading edge
of this renaissance to modernize industrial technology. We look forward to partnering
with you to develop an innovative Control & Communications Systems platform that
carries your business or utility into this exciting new Age of Information.
The evolution of the PACSystems portfolio is a prime
example of GE Intelligent Platform’s commitment to
control system modernization. Our PACSystems
customers realize higher performance, improved
uptime and lower total cost of ownership through
innovations such as COMExpress technology on a
PROFINET backbone.
6
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Table of Contents
PACSystems RX7i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3
Configuration Guidelines; Typical Application. . . . . . . . 1.63
CPUs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4
α and βi Series Servo Amplifiers. . . . . . . . . . . . . . . . . . . . 1.66
Racks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.6
VersaMotion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.67
Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.7
I/O Interface Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.8
Communications Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . 1.9
Accessories and Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.10
Series 90-70. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.76
CPU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.77
Racks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.78
Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.80
PACSystems RX3i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.11
I/O Interface Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.81
CPUs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.12
Communications Module. . . . . . . . . . . . . . . . . . . . . . . . . . . 1.82
Baseplates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.15
Accessories and Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.83
Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.16
Discrete Input Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.19
Analog Input Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.22
Discrete Output Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . 1.27
Analog Output Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.32
Analog Mixed Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.36
Millivolt I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.37
RTD I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.39
Strain Gage I/O Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.41
Temperature Control Modules. . . . . . . . . . . . . . . . . . . . . . 1.43
Thermocouple I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . 1.44
Resistive I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.47
Network and Distributed I/O Systems. . . . . . . . . . . . . . . 1.48
Series 90-30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.84
CPUs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.85
Baseplates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.88
Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.89
Discrete I/O Modules (Input) . . . . . . . . . . . . . . . . . . . . . . . . 1.91
Analog I/O Modules (Input) . . . . . . . . . . . . . . . . . . . . . . . . . 1.94
Discrete I/O Modules (Output). . . . . . . . . . . . . . . . . . . . . . . 1.96
Analog I/O Modules (Output). . . . . . . . . . . . . . . . . . . . . . . 1.101
Millivolt I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.103
RTD I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.104
Strain Gage I/O Modules . . . . . . . . . . . . . . . . . . . . . . . . . . 1.105
Temperature Control Modules. . . . . . . . . . . . . . . . . . . . . 1.106
Thermocouple I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . 1.107
Network and Distributed I/O Systems. . . . . . . . . . . . . . 1.109
Motion Control (High Speed Counting). . . . . . . . . . . . . . . 1.51
Serial Communications Modules. . . . . . . . . . . . . . . . . . . 1.112
PACMotion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.52
Power Measurement Modules. . . . . . . . . . . . . . . . . . . . . 1.113
Motion Control (Servo Control). . . . . . . . . . . . . . . . . . . . . . 1.54
Pneumatic Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.114
Power Measurement Modules. . . . . . . . . . . . . . . . . . . . . . 1.55
Programmable Coprocessor Modules. . . . . . . . . . . . . . 1.115
Pneumatic Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.56
Motion Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.116
Expansion Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.57
Remote Expansion Modules. . . . . . . . . . . . . . . . . . . . . . . 1.118
Accessories; Terminal Blocks; Cables; Kits. . . . . . . . . . . 1.58
Co-Processor and Serial
Communications Modules. . . . . . . . . . . . . . . . . . . . . . . . . . 1.50
www.ge-ip.com
Continued next page
GE Intelligent Platforms Control Systems Solutions
1.1
Table Of Contents
Programmable Controllers
Series 90-30 Continued
Portable Program Download Device (PPDD). . . . . . . . 1.119
Accessories; Cables; Terminal Blocks. . . . . . . . . . . . . . . 1.121
Configuration Guidelines; Typical Applications. . . . . . 1.123
α and βi Series Servo Amplifiers. . . . . . . . . . . . . . . . . . . 1.124
VersaMotion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.125
VersaMax Nano and Micro. . . . . . . . . . . . . . . . . . . . . . . . . 1.134
Nano PLCs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.136
Micro PLCs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.137
Discrete Expansion Selection Guide. . . . . . . . . . . . . . . . 1.145
Discrete Expansion Units. . . . . . . . . . . . . . . . . . . . . . . . . . 1.146
Analog Expansion Selection Guide. . . . . . . . . . . . . . . . . 1.152
Analog Expansion Units. . . . . . . . . . . . . . . . . . . . . . . . . . . 1.153
Micro Motion Expansion Units . . . . . . . . . . . . . . . . . . . . . 1.156
DataPanels Operator Interfaces. . . . . . . . . . . . . . . . . . . 1.157
Communications Options. . . . . . . . . . . . . . . . . . . . . . . . . . 1.158
Portable Program Download Device (PPDD). . . . . . . . 1.160
Accessories; Power Supplies; Cables. . . . . . . . . . . . . . . 1.162
Starter Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.163
Configuration Guidelines; Typical Applications. . . . . . 1.164
VersaMotion Servo Motors and Amplifiers. . . . . . . . . . 1.166
Durus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.174
AC Models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.175
DC Models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.177
Discrete Expansion Units. . . . . . . . . . . . . . . . . . . . . . . . . . 1.181
Analog Expansion Units. . . . . . . . . . . . . . . . . . . . . . . . . . . 1.182
Communications Options. . . . . . . . . . . . . . . . . . . . . . . . . . 1.183
Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.184
Accessories; Starter Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . 1.185
Configuration Guidelines; Typical Applications. . . . . . 1.186
1.2
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX7i
PACSystems RX7i Controllers
Built on a standard embedded open
architecture, the PACSystems RX7i is
the first member of the groundbreaking
PACSystems family of programmable
controllers (PACs). The RX7i ­features
a single control engine and ­universal
programming environment to provide
application portability across multiple
hardware platforms. Designed to
address mid- to high-end ­applications
for OEMs, integrators, and end users,
the RX7i is ideally suited for integrated
solutions that require open architecture, large memory, distributed I/O
and high ­performance.
The RX7i Features
• Pentium® CPUs for your every need,
from Celeron 300mHz to M Class
1.8 Ghz
• VME64 architecture supporting
new and older VME embedded
technology with fast through put of
large amounts of data.
• 10/100 Ethernet built into the CPU,
with easy cabling RJ-45 dual ports
connected through an auto-sensing
switch, so there is no need for
additional switches or hubs rack
to rack
• Up to 64 MB memory for fast execution,
storage of the complete program with
all documentation—all in one CPU
• In addition, it provides an outstanding
migration path for any Series 90
applications to move to the
PACSystems architecture.
Proficy Machine Edition
Proficy Machine Edition is an
advanced software environment for
the development and maintenance
of machine level automation.
Visualization, motion control, and
­execution logic are developed with
a single ­programmer.
I/O Interface Modules
Accessories
CPUs
page 1.8
page 1.10
pages 1.4-1.5
Racks
page 1.6
Power Supplies
page 1.7
Communications Modules
page 1.9
Publication Reference Chart
GFK-2222
PACSystems CPU Reference Manual
GFK-2223
PACSystems RX7i Installation Manual
GFK-2224
TCP/IP Ethernet Communications
for PACSystems
GFK-2225
PACSystems Station Manager
User’s Manual
GFK-2235
PACSystems RX7i User’s Guide to
Integration of VME Modules
GFK-2259
C Programmer’s Toolkit for PACSystems
User’s Manual
GFK-2300
PACSystems RX7i Memory Xchange
Modules User’s Manual
GFK-2308
PACSystems Hot Standby CPU
Redundancy User’s Guide
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.3
PACSystems RX7i
Programmable Controllers
CPUs
PACSystems RX7i CPUs feature Intel Celeron and Pentium III processors and offer fast
execution, larger memory capacity and upgradability to track future technology growth.
RX7i CPUs are available with various memory sizes, performance capabilities and advanced
functionalities, such as software configuration of data and program memory. PACSystems
CPUs also provide 10K of user RAM along with 10K of non-volatile user flash memory for
added protection of your data and programs.
IC698CPE020†
IC698CRE020†
Product Name
Central Processing Unit,
700 MHz, Floating Point
Redundancy Central Processing Unit,
700 MHz, Floating Point
Lifecycle Status
Active
Active
700 MHz
700 MHz
10 Mbytes of User Logic RAM
10 Mbytes of User Logic RAM
Yes (10 Mbytes)
Yes (10 Mbytes)
Yes
Yes
32 Kbits
32 Kbits
%W: Configurable up to 4 Mbytes,
Symbolic: Configurable up to 10 Mbytes
%W: Configurable up to the maximum available user RAM,
Symbolic: Configurable up to 10 Mbytes
Serial, Ethernet
Serial, Ethernet
Modbus RTU Slave, SNP, Serial I/O
Modbus RTU Slave, SNP, Serial I/O
2 Serial (RS-232, RS-485) 1 Ethernet (Auto 10/100, RJ45)
2 Serial (RS-232, RS-485) 1 Ethernet (Auto 10/100, RJ45)
4.0 Amps
4.0 Amps
PACSystems Processor Speed
PACSystems CPU Memory
PACSystems User Flash Memory
Floating Point Math
PACSystems I/O Discrete Points Available
Other Memory Allocations
Embedded Communications
Protocols Supported
Built-in Ports
Current Required from 5V Bus
†Requires
1.4
fan kit.
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX7i
CPUs
PACSystems RX7i CPUs feature Intel Celeron and Pentium III processors and offer fast
execution, larger memory capacity and upgradability to track future technology growth.
RX7i CPUs are available with various memory sizes, performance capabilities and advanced
functionalities, such as software configuration of data and program memory. PACSystems
CPUs also provide 10K of user RAM along with 10K of non-volatile user flash memory for
added protection of your data and programs.
IC698CPE030
IC698CPE040†
IC698CRE030
IC698CRE040†
Product Name
Pentium M Central
Processing Unit,
600 MHz
Pentium M Central
Processing Unit,
1.8 GHz
Pentium M Redundancy
Central Processing Unit,
600 MHz
Pentium M Redundancy
Central Processing Unit,
1.8 GHz
Lifecycle Status
Active
Active
Active
Active
600 MHz
1.8 GHz
600 MHz
1.8 GHz
PACSystems CPU Memory
64 Mbytes
64 Mbytes
64 Mbytes
64 Mbytes
PACSystems User Flash Memory
64 Mbytes
64 Mbytes
64 Mbytes
64 Mbytes
Yes
Yes
Yes
Yes
32 Kbits
32 Kbits
32 Kbits
32 Kbits
%W: Configurable up to the
maximum available user RAM
Symbolic: Configurable up
to the maximum available
user RAM
%W: Configurable up to the
maximum available user RAM
Symbolic: Configurable up
to the maximum available
user RAM
%W: Configurable up to the
maximum available user RAM
Symbolic: Configurable up
to the maximum available
user RAM
%W: Configurable up to the
maximum available user RAM
Symbolic: Configurable up
to the maximum available
user RAM
Serial, Ethernet
Serial, Ethernet
Serial, Ethernet
Serial, Ethernet
Modbus RTU Slave, SNP,
Serial I/O
Modbus RTU Slave, SNP,
Serial I/O
Modbus RTU Slave, SNP,
Serial I/O
Modbus RTU Slave, SNP,
Serial I/O
2 Serial (RS-232, RS-485)
1 Ethernet (Auto 10/100, RJ45)
2 Serial (RS-232, RS-485)
1 Ethernet (Auto 10/100, RJ45)
2 Serial (RS-232, RS-485)
1 Ethernet (Auto 10/100, RJ45)
2 Serial (RS-232, RS-485)
1 Ethernet (Auto 10/100, RJ45)
3.2 A
6.8 A
3.2 A
6.8 A
up to 16 web server and FTP
connections (combined)
up to 16 web server and FTP
connections (combined)
up to 16 web server and FTP
connections (combined)
up to 16 web server and FTP
connections (combined)
PACSystems Processor Speed
Floating Point Math
PACSystems I/O Discrete Points Available
Other Memory Allocations
Embedded Communications
Protocols Supported
Built-in Ports
Current Required from 5V Bus
Web Based Data Monitoring
†Requires
fan kit.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.5
PACSystems RX7i
Programmable Controllers
Racks
PACSystems RX7i Racks set the pace for the latest PLC technology. They are built to
support the high-power PACSystems power supplies along with the latest technology in
the PACSystems CPUs. The VME64 backplane provides up to four times the bandwidth of
existing VME based systems for faster I/O throughput. The VME64 base supports all
­standard VME modules including I/O and VMIC modules.
IC698CHS009
IC698CHS017
IC698CHS109
IC698CHS117
IC698CHS217
Standard PACSystems
9-slot Wall
(Rear) Mount
Standard PACSystems
18-slot Wall
(Rear) Mount
Standard PACSystems
9-slot Wall
(Panel) Mount
Standard PACSystems
18-slot Wall
(Panel) Mount
PACSystems
17-slot Wall
(Rear) Mount,
Rear I/O Access
Lifecycle Status
Active
Active
Active
Active
Active
Number of Slots
9 Single Width,
5 Double Width
(plus one for
power supply)
15 Single Width,
8 Double Width
(plus one for
power supply)
9 Single Width,
5 Double Width
(plus one for
power supply)
15 Single Width,
8 Double Width
(plus one for
power supply)
17 Single Width,
8 Double Width
(plus one for
power supply)
Rear (Panel)
Rear (Panel)
Front (Rack)
Front (Rack)
Rear (Panel)
RX7i CPU and I/O,
VME modules
RX7i CPU and I/O,
VME modules
RX7i CPU and I/O,
VME modules
RX7i CPU and I/O,
VME modules
RX7i CPU and I/O,
VME modules (with or
without rear access
connections)
0.8 inch
0.8 inch
0.8 inch
0.8 inch
0.8 inch
RX7i Power Supply
(IC698)
RX7i Power Supply
(IC698)
RX7i Power Supply
(IC698)
RX7i Power Supply
(IC698)
RX7i Power Supply
(IC698)
11.15”H x 12.6”W x 7.25”D
(283 x 320 x 184mm)
11.15” x 19.00” x 7.5”
11.15”H x 12.6”W x 7.25”D
(283 x 320 x 184mm)
11.15” x 19.00” x 7.5”
11.15”H x 19”W x 8.875”D
(8.97”D with rear I/O
cover) (283 x 483 x
225mm) (228mm D with
rear I/O cover)
Product Name
Mounting Location
Rack Configurations
Rack Slot Size
Compatible Power Supplies
Dimensions
1.6
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX7i
Power Supplies
PACSystems RX7i Power Supply modules simply slide into the PLC rack just like I/O, and they
work with any PACSystems CPU. The low capacity power supply delivers up to 100W total
output without forced air cooling. The high capacity power supply accommodates applications requiring more power, providing up to 350W total output, and requires forced air cooling, provided by a fan tray mounted on the bottom of the rack. PACSystems power supplies
also have built-in protection for autoranging power factor corrections as well as overcurrent, overvoltage, and overtemperature fault conditions.
IC698PSA100
IC698PSA350
IC698PSD300
Product Name
PACSystems Power Supply, 100 W
PACSystems Power Supply, 350 W
PACSystems Power Supply, 300 W
Lifecycle Status
Active
Active
Active
Power Source
85-264 VAC or 125 VDC
85-264 VAC or 125 VDC
18-30 VDC
Output Source
100 Watts; 5 VDC @ 20 Amps, +12 VDC
@ 2 Amps, -12 VDC @ 1 Amp
350 Watts; 5 VDC @ 60 Amps, +12 VDC
@ 12 Amps, -12 VDC @ 4 Amps
300 Watts; 5 VDC @ 50 Amps, +12 VDC
@ 10 Amps, -12 VDC @ 4 Amps
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.7
PACSystems RX7i
Programmable Controllers
I/O Interface Modules
PACSystems features a variety of communications options for distributed control
and/or I/O, supporting a wide range of communication protocols and configurations.
These communication modules are easy to install and quick to configure. Some ­distributed
I/O communications modules allow for numerous remote drops or additional racks, while
others provide an interface for GE products up to 7500 feet away from the controller.
IC697BEM731
IC687BEM731
IC697BEM713
IC697BEM711
IC697BEM733
Genius Bus Controller
VME Single Slot
Bus Controller
Bus Transmitter Module
Bus Receiver Module
Remote I/O Scanner
Mature
Active
Mature
Mature
Mature
Bus Controller
Bus Controller
Bus Transmitter
Bus Receiver Scanner
Remote I/O
Supports Redundancy
Yes
Yes
No
No
Yes
Discrete Points Available
N/A
N/A
N/A
N/A
128 Bytes Per Drop
Programmer Effective Data Rate
N/A
N/A
500 Kbytes/sec
N/A
N/A
Time to Store 16 Kbyte Program
N/A
N/A
20 - 30 Seconds
N/A
N/A
Effective Data Rate
N/A
N/A
500 Kbytes/sec
500 Kbytes/sec
38.4 Kbaud
Total Allowed Distance of
Interconnecting Cable
N/A
N/A
50 feet (15 meters)
50 feet (15 meters)
N/A
Maximum Distance from Controller
N/A
N/A
N/A
N/A
7500 feet (2275 meters)
N/A
N/A
Non-isolated differential
communication
Non-isolated differential
communication
N/A
1 (Hand Held
Monitor Port)
1 (Hand Held
Monitor Port)
2 (Programmer Port,
Expansion Port Out)
2 (Expansion Port In,
Expansion Port Out)
2 (RS-422 Compatible
Serial Port, Hand Held
Monitor Port)
1.3 Amps
1.3 Amps
1.4 Amps
0.8 Amp
0.8 Amp
Product Name
Lifecycle Status
Module Type
Electrical Isolation
Built-in Serial Ports
Current Required from 5V Bus
1.8
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX7i
Communications Modules
PACSystems features a variety of communications options for distributed control
and/or I/O, supporting a wide range of communication protocols and configurations.
These communication modules are easy to install and quick to configure. Some ­distributed
I/O communications modules allow for numerous remote drops or additional racks, while
others provide an interface for GE products up to 7500 feet away from the controller.
IC698RMX016
IC698CMX016
IC698ETM001
Product Name
Redundancy Memory
Xchange Module
Control Memory
Xchange Module
RX7i Standalone
Ethernet Module 10/100
Lifecycle Status
Active
Active
Active
Redundancy Communications
(High Availability)
Control Memory Xchange
Ethernet Controller
Supports Redundancy
Yes
No
No
Protocols Supported
N/A
N/A
N/A
Effective Data Rate
2.12 gigabaud
2.12 gigabaud
N/A
Electrical Isolation
Non-isolated differential
communication
Non-isolated differential
communication
N/A
Communications Processor Speed
N/A
N/A
N/A
Simultaneous Communication Speed
N/A
N/A
N/A
Individual Communication Speed
N/A
N/A
N/A
16 Mbytes
16 Mbytes
N/A
Up to 300 meters
Up to 300 meters
N/A
Access Time
400 ns (worst-case),
200 ns (best-case)
400 ns (worst-case),
200 ns (best-case)
N/A
6.2 Mbyte/s without
redundant transfer,
3.2 Mbyte/s with
redundant transfer
N/A
Transfer Rate
6.2 Mbyte/s without
redundant transfer,
3.2 Mbyte/s with
redundant transfer
Connector
(LC type, conforms to IEC61754-20)
Cable (ST Type Fiber-Optic
Multimode; 62.5 Micron core)
Connector
(LC type, conforms to IEC61754-20)
Cable (ST Type Fiber-Optic
Multimode; 62.5 Micron core)
N/A
None
None
2 Twisted pair 10 Base
T/100 Base TX RJ-45
1.2 Amps
1.2 Amps
N/A
Module Type
Reflective Memory Available
Distance Between Nodes
Cable Requirements
Built-in Serial Ports
Current Required from 5V Bus
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.9
PACSystems RX7i
Programmable Controllers
Accessories
IC690CDR002
User Manuals, InfoLink CD-ROM Documentation, Single-user License
Active
IC697ACC621
Short Rack Fan Assembly, 120 VAC
Active
IC697ACC624
Short Rack Fan Assembly, 240 VAC
Active
IC697ACC644
Short Rack Fan Assembly, 24 VDC
Active
IC697ACC721
Rack Fan Assembly, 120 VAC
Active
IC697ACC724
Rack Fan Assembly, 240 VAC
Active
IC697ACC736
Cable Shield Clamping Assembly
Active
IC697ACC744
Rack Fan Assembly, 24 VDC
Active
IC698ACC701
Replacement Battery
Active
IC698ACC720
Gasketed Filler Faceplate, Double-width
Active
IC698ACC735
Gasketed Filler Faceplate, Single-width
Active
IC200CBL001
Station Manager Cable for Ethernet Interface
Active
IC600WD002
I/O Expansion Cable, 2 feet (0.6 meters)
Mature
IC600WD005
I/O Expansion Cable, 5 feet (1.5 meters)
Mature
IC600WD010
I/O Expansion Cable, 10 feet (3.0 meters)
Mature
IC600WD025
I/O Expansion Cable, 25 feet (7.5 meters)
Mature
IC600WD050
I/O Expansion Cable, 50 feet (15 meters)
Mature
Cables
1.10
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
PACSystems RX3i Controllers
PACSystems RX3i is the high performance, modular and scalable control system that supports the PACSystem engine. This
rack-based system is built on PCI standards and provides fast, consistent control between the modules. In addition to more
than one hundred discrete and process I/O points, the PACSystems RX3i features:
• PACSystems High Availability – This
scalable, synchronized, hot-standby
redundancy control platform helps
ensure uninterrupted control of your
applications and processes — with
total transparency.
• PACMotion Controller – Our versatile
servo motion controller combines
the benefits of a highly integrated
motion and machine logic solution,
with the performance, flexibility and
scalability required for advanced
machine automation.
• Proficy Process Systems – A
scalable, fully integrated system for
process automation and control.
• Integrated PROFINET provides real
time control of distributed I/O.
PACSystems RX3i also offers an
outstanding migration path for
moving any Series 90 application to
the PACSystems architecture.
• Proficy Machine Edition – Develop,
configure and maintain all of your
control functions including motion,
visualization and networking with
complete software package.
Discrete Input Modules
Discrete Output Modules
Analog Input Modules
Analog Output Modules Power Supplies
pages 1.16-1.18
Baseplates
page 1.15
CPUs
pages 1.12-1.13
pages 1.19-1.21
pages 1.27-1.31
pages 1.22-1.26
pages 1.32-1.35
Pneumatic Module
Expansion Modules
Specialty Modules
page 1.56
page 1.57
pages 1.36-1.47, 1.51
Serial Communication Modules PACMotion
Publication Reference Chart
page 1.51
pages 1.52-1.53
Networks and Distributed
I/O Systems pages 1.48-1.49
RX3i Accessories
pages 1.58-1.62
GFK-2222
PACSystems CPU Reference Manual
GFK-2224
TCP/IP Ethernet Communications for
PACSystems
GFK-2225
PACSystems Station Manager User’s
Manual
RX3i Configuration Guidelines
pages 1.63-1.65
GFK-2259
C Programmer’s Toolkit for PACSystems
User’s Manual
α and βi Series Servo Amplifiers page 1.66
GFK-2308
PACSystems Hot Standby CPU
Redundancy User’s Manual
VersaMotion
GFK-2314
PACSystems RX3i Hardware and
Installation Manual
www.ge-ip.com
pages 1.67-1.75
GE Intelligent Platforms Control Systems Solutions
1.11
PACSystems RX3i
Programmable Controllers
CPUs
The high-performance CPU is based on the latest technology processor with fast computation
and high throughput. The controller can manage up to 32K of I/O in a number of standard
languages. The powerful CPU enables complex applications to be easily solved with the high
performance processor and up to 64 Mbytes of user memory. The RX3i supports ­multiple IEC
languages and C programming to give you program flexibility. The RX3i increases machine
cycle times, reduces downtime with its extensive diagnostics and hot swap capability, and
enables you to store large amounts of data to reduce external hardware cost.
Product Name
Lifecycle Status
Module Type
Backplane Support
Boolean Execution Speed (ms/K)
User Logic Memory
Battery Backed Real Time Clock
IC695CPE305
IC695CPE310
IC695CPU320
IC695CPU315
RX3i CPU with built-in USB
Master port, Ethernet port
and serial port
RX3i CPU with built-in USB
Master port, Ethernet port
and 2 serial ports
RX3i CPU with two built-in
serial ports
RX3i CPU with two built-in
serial ports
Active
Active
Active
Active
Controller
Controller
Controller
Controller
Universal Backplane Only.
Uses PCI Bus.
Universal Backplane Only.
Uses PCI Bus.
Universal Backplane Only.
Uses PCI Bus.
Universal Backplane Only.
Uses PCI Bus.
.072
.072
0.047
0.047
5Meg bytes
10Meg bytes
64Mega bytes
20Meg bytes
Yes
Yes
Yes
Yes
Energy Pack Support
(Battery-less Backup)
Energy Pack Support
(Battery-less Backup)
Battery Backup only
Battery Backup only
I/O Discrete Points
32K
32K
32K
32K
I/O Analog Points
32K
32K
32K
32K
Dynamic Data Back-up
Type of Memory Storage
SRAM, Flash
SRAM, Flash
SRAM, Flash
SRAM, Flash
Processor Speed (MHz)
1.1GHz
1.1GHz
1GHz
1GHz
Yes. CPU application upload/
download to a Thumb Drive or
Smart Phone
No
No
USB -A 2.0 Master Port
Yes. CPU application upload/
download to a Thumb Drive or
Smart Phone
Built-in Ethernet Ports
One RJ-45 port, 10/100Mbaud. One RJ-45 port, 10/100Mbaud.
SRTP support for
SRTP support for
programmer only
programmer only
Built-in Serial Ports
One RS-232 port.
One RS-485 port and one RS-232
One RS-485 port and one
One RS-485 port and one RS-232
Supports SNP, Serial I/O, Modbus
port. Supports SNP, Serial I/O, RS-232 port. Supports SNP, Serial
port. Supports SNP, Serial I/O,
Slave and Modbus Master
Modbus Slave and Modbus
I/O, Modbus Slave and Modbus
Modbus Slave and Modbus
(Application code)
Master (Application code)
Master (Application code)
Master (Application code)
Total Number of Local Racks
8
8
8
Serial, Genius, CMX (Reflective Memory), Ethernet
Communications Options
Field Busses/Device Networks
8
Ethernet (Profinet, Ethernet Global Data, Channels, Modbus TCP Server and Client), Genius, Profibus DP, DeviceNet
Software Programming Support
Proficy Machine Edition Logic
Developer Professional edition
7.0 SIM 3 or above
Proficy Machine Edition Logic
Developer Professional edition
7.0 SIM 3 or above
Proficy Machine Edition Logic
Developer Professional edition
5.6 or above
Proficy Machine Edition Logic
Developer Professional edition
5.6 or above
Program Languages Supported
Ladder Logic, Structured Text,
C, Function Block Diagram
Ladder Logic, Structured Text,
C, Function Block Diagram
Ladder Logic, Structured Text,
C, Function Block Diagram
Ladder Logic, Structured Text,
C, Function Block Diagram
1750 mA @ 3.3 VDC; 1200 mA
@ 5 VDC
1750 mA @ 3.3VDC;
1200 mA @ 5VDC
(Check Data sheet)
2
2
Internal Power Used
Number of Slots Module
Occupies on Backplane
1.12
+3.3 VDC: 1.0 A +5 VDC: 1.0 A
+3.3 VDC: 1.0 A +5 VDC: 1.0 A
(up to 1.5 A if USB is fully loaded (up to 1.5 A if USB is fully loaded
with 0.5 A) +24 VDC: 0.5A at
with 0.5 A) +24 VDC: 0.5A at
startup, 0.1 A during run time
startup, 0.1 A during run time
(Applies only if Energy Pack is
(Applies only if Energy Pack is
connected to the CPE305.)
connected to the CPE305.)
1
GE Intelligent Platforms Control Systems Solutions
2
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
High Availability Redundant Controllers
High Availability CPU Redundancy family allows critical application or process to continue operating if a failure
occurs in any single component. A High Availability system uses two or more CPUs; an active unit that actively
controls the process, and one or more backup units that are synchronized with the active unit and can take over
the process should it becomes necessary.
An RX3i QuadPAC solution utilizes four CRU320QP controllers — one is a master controller and three are synchronized backup controllers. The QuadPAC solution features “Smart Redundancy,” a patent pending algorithm that
calculates the relative system availability in real time and identifies the most available controller as master. The
I/O racks may be grouped into either single (one I/O rack), redundant (two I/O racks), or triple redundant (three I/O
racks) rack configurations.
IC695CRU320
IC695CRU320QP
Product Name
RX3i Bumpless Redundant High Availability CPU
with two built-in serial ports.
(Requires IC695RMX128 Data Sync Module)
QuadPAC CPU for RX3i Bumpless Redundant High Availability
CPU with two built-in serial ports. (Requires IC695RMX128
Data Sync Module AND Quad Redundancy Solution Code)
Lifecycle Status
Active
Active
Module Type
Backplane Support
Boolean Execution Speed (ms/K)
User Logic Memory
Redundant Controller
Quad System Redundant Controller
Universal Backplane Only. Uses PCI Bus.
Universal Backplane Only. Uses PCI Bus.
0.047
0.047
64Meg bytes
64Meg bytes
Battery Backed Real Time Clock
Yes
Yes
I/O Discrete Points
32K
32K
I/O Analog Points
32K
32K
Type of Memory Storage
SRAM, Flash
SRAM, Flash
Dynamic Data Back-up
Battery Backup only
Battery Backup only
1GHz
1GHz
One RS-485 port and one RS-232 port. Supports SNP, Serial I/O,
Modbus Slave and Modbus Master (Application code)
One RS-485 port and one RS-232 port. Supports SNP, Serial I/O,
Modbus Slave and Modbus Master (Application code)
Processor Speed
Built-in Communication Ports
Total Number of Racks
8
8
Serial, Genius, CMX, Ethernet, Profinet, Profibus,
and DeviceNet
Serial, Genius, CMX, Ethernet, Profinet, Profibus,
and DeviceNet
Ethernet (Ethernet Global Data, Channels, Modbus TCP
Server and Client), Profibus DP, DeviceNet
Ethernet (Ethernet Global Data, Channels, Modbus TCP
Server and Client), Profibus DP, DeviceNet
Software Programming Support
Proficy Machine Edition Logic Developer
Professional edition 5.7 or above
Proficy Machine Edition Logic Developer
Professional edition 7.0 SIM 8 or above
Program Languages Supported
Ladder Logic, Structured Text, C, Function Block Diagram
Ladder Logic, Structured Text, C, Function Block Diagram
Redundancy Maximum amount
of data in for Syncronization
Up to 2 Mbytes beginning and end of scan
Up to 2 Mbytes beginning and end of scan
3.66 msec: 1K Discrete I/O, 125 Analog I/O and 1K Registers
3.87 msec: 2K Discrete I/O, 250 Analog I/O and 2K Registers
4.30 msec: 4K Discrete I/O, 500 Analog I/O and 4K Registers
5.16 msec: 8K Discrete I/O, 1K Analog I/O and 8K Registers
3.66 msec: 1K Discrete I/O, 125 Analog I/O and 1K Registers
3.87 msec: 2K Discrete I/O, 250 Analog I/O and 2K Registers
4.30 msec: 4K Discrete I/O, 500 Analog I/O and 4K Registers
5.16 msec: 8K Discrete I/O, 1K Analog I/O and 8K Registers
Maximum 1 logic scan, minimum 3.133 msec.
Maximum 1 logic scan, minimum 3.133 msec.
Automatic Each Scan
Automatic Each Scan
Yes
Yes
Communications Options
Field Busses/Device Networks
Redundancy Typical Base Sweep Time
(Reference Data Transfer List Impact)
Redundancy Switchover Time
CPU Scan Syncronization
Redundant Synch LAN
Redundant I/O LAN
Yes
Yes
Internal Power Used
1750 mA @ 3.3 VDC; 1200 mA @ 5 VDC
1750 mA @ 3.3 VDC; 1200 mA @ 5 VDC
2
2
Number of Slots Module
Occupies on Backplane
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.13
PACSystems RX3i
Programmable Controllers
High Availability Data Synch
The Redundancy Memory Xchange (RMX) module operates as a dedicated link between
CPUs in an RX3i Hot Standby CPU (IC695CRU320) Redundancy system. The RMX modules
provide a path for transferring data between the two redundancy CPUs in the redundant
system. A complete communications path consists of one RMX in the primary unit, one RMX
in the secondary unit, and two high-speed fiber optic cables connecting them to each other.
One or two redundancy links are supported per high availability CPU.
IC695RMX128
Product Name
RX3i Control Memory Xchange Module for
Peer to Peer network. 128Megbytes of
user shared memory.
Lifecycle Status
Active
Module Type
Backplane Support
High Availability Data Syncronization Link
Universal Backplane Only. Uses PCI Bus.
Sync Link Speed
2.1 Gbits/s
Communications Data Rate
2.12Gbaud
Synchronzed Link Transfer Rate
43 Mbyte/s (4 byte packets) to
174 Mbyte/s (64 byte packets)
Maximum Data Syncronization
Up to 2 megabytes. Twice per Scan.
Bus Diagnostics
Network error detection.
Redundant RMX Support
Yes
Maximum Distance Between
Redundant Controllers
Connector Type
Internal Power Used
300 meters
-Fiber optic LC type, conforms to IEC 61754-20
- Zirconium ceramic ferrule
-Insertion loss: 0.35 dB (maximum)
-Return loss: -30dB
660 mA @ +3.3 VDC 253 mA @ +5 VDC
Number of Slots Module
Occupies on Backplane
1.14
GE Intelligent Platforms Control Systems Solutions
1
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Baseplates
RX3i baseplates are available in 7, 12 and 16 slot configurations to the meet the needs
of your application. The RX3i Universal baseplates support hot swap capability to reduce
downtime. Expansion bases are available in 5 and 10 slot versions to maximize flexibility.
IC695CHS007
IC695CHS012
IC695CHS016
IC694CHS398
IC693CHS399
IC694CHS392
IC693CHS393
Product Name
PACSystems RX3i
7 slot high speed
controller base
supports only
5 serial bus slots
supported.
Not expandable.
PACSystems RX3i
12 slot high speed
controller base
supports PCI
and serial bus
PACSystems RX3i
16 slot high speed
controller base
supports PCI
and serial bus
PACSystems RX3i
serial 5-slot
Expansion
Baseplate
(serial bus only)
PACSystems RX3i
serial 5-slot Remote
Baseplate
(serial bus only)
PACSystems RX3i
serial 10-slot
Expansion
Baseplate
(serial bus only)
PACSystems RX3i
serial 10-slot
Remote Baseplate
(serial bus only)
Lifecycle Status
Active
Active
Active
Active
Active
Active
Active
Universal Controller and I/O Base
Universal
Controller and
I/O Base
Universal
Controller and
I/O Base
Standard I/O
Standard I/O
Standard I/O
Standard I/O
Supports both
PCI and High
Speed Serial
Supports both
PCI and High
Speed Serial.
Supports both
PCI and High Speed
Serial.
Supports High
Speed Serial Only.
No PCI support.
Supports High
Speed Serial Only.
No PCI support.
Supports High
Speed Serial Only.
No PCI support.
Supports High
Speed Serial Only.
No PCI support.
Yes
Yes
Yes
No
No
No
No
Controller Base
and Ethernet
Expansion Base.
No local
base expansion
Controller Base
and Ethernet
Expansion Base
Controller Base
and Ethernet
Expansion Base
Expansion
Expansion
Expansion
Expansion
N/A
N/A
N/A
Up to 50 feet
Up to 700 feet
Up to 50 feet
Up to 700 feet
7
12
16
5
5
10
10
Dimension
(W x H x D) in. (mm)
10.43 x 5.57 x 5.80
(265 x 141.5 x
147.32)
18.01 x 5.57 x 5.80
(457.5 x 141.5 x
147.32)
23.7 x 5.57 x 5.80
(601.98 x 141.5 x
147.32)
10.43 x 5.12 x 5.59
(245 x 130 x 142)
10.43 x 5.12 x 5.59
(245 x 130 x 142)
17.44 x 5.12 x 5.59
(443 x 130 x 142)
17.44 x 5.12 x 5.59
(443 x 130 x 142)
Internal Power Used
600 mA @ 3.3 VDC; 600 mA @ 3.3 VDC; 600 mA @ 3.3 VDC;
240 mA @ 5 VDC
240 mA @ 5 VDC
240 mA @ 5 VDC
170 mA @ 5 VDC
480 mA @ 5 VDC
150 mA @ 5 VDC
460 mA @ 5 VDC
Module Type
Backplane Support
Module Hot Swap Support
Baseplate Option
Distance
Number of Slots
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.15
PACSystems RX3i
Programmable Controllers
Universal Bases Power Supplies
The RX3i power supply modules simply snap in just like I/O, and they work with any model
CPU. Each version provides auto-ranging so there is no need to set jumpers for different
incoming power levels, and they are current limiting so a direct short will shut the power
supply down to avoid damage to the hardware. Advanced diagnostics and built-in smart
switch fusing are among the other performance and safety features. The multipurpose
power supplies can be configured for incremental capacity or redundancy.
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Power Source
Redundant and Added
Capacity Support
Output Source
IC695PSA040
IC695PSD040
IC695PSA140
IC695PSD140
Power Supply, 120/240 VAC,
125 VDC (Can not be on the
same backplane with more
than one power supply)
Power Supply, 24 VDC
(Can not be on the same
backplane with more
than one power supply)
Multipurpose Power Supply,
120/240 VAC, 125 VDC.
Supports multiple multipurpose power supplies.
Multipurpose Power Supply,
24 VDC. Supports multiple
multipurpose power supplies.
Active
Active
Active
Active
Universal Base Power Supply
Universal Base Power Supply
Universal Base Power Supply
Universal Base Power Supply
Universal Backplane Only.
Uses PCI Bus.
Universal Backplane Only.
Uses PCI Bus.
Universal Backplane Only.
Uses PCI Bus.
Universal Backplane Only.
Uses PCI Bus.
2
1
2
1
100-240 VAC or 125 VDC
24 VDC
100-240 VAC or 125 VDC
24 VDC
No
No
Yes, Up to 4 Multipurpose
power supplies supported
on a Universal base
Yes, Up to 4 Multipurpose
power supplies supported
on a Universal base
40 watts total. 30 watts max
at 3.3 VDC; 30 watts max at 5
VDC; 40 watts at 24 VDC Relay,
no 24 VDC isolated available.
40 watts total. 30 watts max
at 3.3 VDC; 30 watts max at
5 VDC; 40 watts at 24 VDC
Relay, no 24 VDC
isolated available
40 watts total. 30 watts max at
3.3 VDC; 30 watts max at
5 VDC; 40 watts at 24 VDC
Relay, no 24 VDC
isolated available
40 watts total. 30 watts max
at 3.3 VDC; 30 watts max at
5 VDC; 40 watts at 24 VDC
Relay, no 24 VDC
isolated available.
N/A
N/A
Two Multipurpose Power
Supplies are supported on
the Universal Base configured
for redundancy
Two Multipurpose Power
Supplies are supported on
the Universal Base configured
for redundancy
Number of Redundant
Power Supplies Supported
1.16
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Remote Base Power Supplies
The RX3i power supply modules simply snap in just like I/O, and they work with any model
CPU. Each version provides auto-ranging so there is no need to set jumpers for different
incoming power levels, and they are current limiting so a direct short will shut the power
supply down to avoid damage to the hardware. RX3i power supplies are tied into the
­performance of the CPU for simplex, fail-safe, and fault tolerance. Advanced diagnostics
and built-in smart switch fusing are among the other performance and safety features.
IC694PWR321
IC694PWR330
IC694PWR331
IC693PWR332
Product Name
Power Supply,
120/240 VAC, 125 VDC
Power Supply,
120/240 VAC, 125 VDC
Power Supply,
24 VDC
Power Supply,
12 VDC
Lifecycle Status
Active
Active
Active
Active
Expansion Power Supply
Expansion Power Supply
Expansion Power Supply
Expansion Power Supply
Remote Bases Only
Remote Bases Only
Remote Bases Only
Remote Bases Only
Power Source
100-240 VAC or 125 VDC
100-240 VAC or 125 VDC
24 VDC
12 VDC
High Capacity
No
Yes
Yes
Yes
Output Source
30 watts total; 15 watts 5 VDC;
15 watts 24 VDC relay;
20 watts 24 VDC isolated
30 watts total; 30 watts 5 V;
15 watts 24 V relay;
20 watts 24 V isolated
30 watts total; 30 watts 5 V;
15 watts 24 V relay;
20 watts 24 V isolated
30 watts total; 30 watts 5 V;
15 watts 24 V relay;
20 watts 24 V isolated
Cable Length to Redundant
Power Supply Adapter
N/A
N/A
N/A
N/A
Redundant Power Supply
Adapter Rack Compatibility
N/A
N/A
N/A
N/A
24 VDC Output Current Capacity
0.8 A
0.8 A
0.8 A
0.8 A
Module Type
Backplane Support
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.17
PACSystems RX3i
Programmable Controllers
Remote Base Power Supplies
The RX3i power supply modules simply snap in just like I/O, and they work with any model
CPU. Each version provides auto-ranging so there is no need to set jumpers for different
incoming power levels, and they are current limiting so a direct short will shut the power
supply down to avoid damage to the hardware. RX3i power supplies are tied into the
­performance of the CPU for simplex, fail-safe, and fault tolerance. Advanced diagnostics
and built-in smart switch fusing are among the other performance and safety features.
IC693PWR328
Product Name
Power Supply,
48 VDC
Lifecycle Status
Active
Module Type
Backplane Support
Expansion Power Supply
Remote Bases Only
Power Source
48 VDC
High Capacity
No
Output Source
30 watts total; 15 watts 5 V;
15 watts 24 V relay;
20 watts 24 V isolated
Cable Length to Redundant
Power Supply Adapter
N/A
Redundant Power Supply
Adapter Rack Compatibility
N/A
24 VDC Output Current Capacity
0.8 A
1.18
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Discrete I/O Modules (Input)
Input modules provide the interface between the PLC and external input devices such as
proximity sensors, push buttons, switches, and BCD thumbwheels. Output modules provide
the interface between the PLC and external output devices such as contactors, interposing
relays, BCD displays and indicator lamps. GE offers a variety of modules that support
different voltage ranges and types, current capacity, isolation and response time to
meet your application needs.
IC694ACC300
IC694MDL230
IC694MDL250
IC694MDL231
IC694MDL240
PACSystems RX3i DC
Voltage Input
Simulator,
8/16 Points
PACSystems RX3i AC
Voltage Input Module,
120 VAC Isolated,
8 Point Input
PACSystems RX3i AC
Voltage Input Module,
120 VAC Isolated,
16 Point Input
PACSystems RX3i AC
Voltage Input Module,
240 VAC Isolated,
8 Point Input
PACSystems RX3i AC
Voltage Input Module,
120 VAC,
16 Point Input
Active
Active
Active
Active
Active
Input Simulator
Discrete Input
Discrete Input
Discrete Input
Discrete Input
No Backplane
Restrictions
No Backplane
Restrictions
No Backplane
Restrictions
No Backplane
Restrictions
No Backplane
Restrictions
1
1
1
1
1
Input Voltage Range
N/A
0-132 VAC
0-132 VAC
0-264 VAC
0-132 VAC
Input Current (mA)
N/A
14.5
14.5
15
12
Number of Points
16
8
16
8
16
20 on/30 off
30 on/45 off
30 on/45 off
30 on/45 off
30 on/45 off
Trigger Voltage
N/A
74-132
74-132
148-264
74-132
Points per Common
16
1
1
1
16
N/A
N/A
N/A
N/A
N/A
Switches
Terminal Block
(20 screws), included
with module.
IC694TBBx32 or
IC694TBSx32.
Sold Separately.
Terminal Block
(20 screws), included
with module.
Terminal Block
(20 screws), included
with module.
120 mA @ 5 VDC
60 mA @ 5 VDC
60 mA @ 5 VDC
60 mA @ 5 VDC
90 mA @ 5 VDC
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Response Time (ms)
Diagnostic Supported
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.19
PACSystems RX3i
Programmable Controllers
Discrete I/O Modules (Input)
Input modules provide the interface between the PLC and external input devices such as
proximity sensors, push buttons, switches, and BCD thumbwheels. Output modules provide
the interface between the PLC and external output devices such as contactors, interposing
relays, BCD displays and indicator lamps. GE offers a variety of modules that support
different voltage ranges and types, current capacity, isolation and response time to
meet your application needs.
IC694MDL260
IC694MDL241
IC694MDL632
IC694MDL634
IC694MDL645
PACSystems RX3i AC
Voltage Input Module,
120 VAC,
32 Point Input
AC/DC Voltage Input
Module, 24 VAC/VDC
PACSystems RX3i DC
Voltage Input Module,
125 VDC Pos/Neg Logic,
8 Point Input
PACSystems RX3i DC
Voltage Input Module,
24 VDC Pos/Neg Logic,
8 Point Input
PACSystems RX3i DC Voltage
Input Module, 24 VDC
Pos/Neg Logic,
16 Point Input
Active
Active
Active
Active
Active
Module Type
Discrete Input
Discrete Input
Discrete Input
Discrete Input
Discrete Input
Backplane Support
No Backplane
Restrictions
No Backplane
Restrictions
No Backplane
Restrictions
No Backplane
Restrictions
No Backplane
Restrictions
1
1
1
1
1
0-132 VAC
0-30 VDC
0-150 VDC
0-30 VDC
0-30 VDC
Input Current (mA)
12
7
4.5
7
7
Number of Points
32
16
8
8
16
30 on/45 off
12 on/28 off
7 on/7 off
7 on/7 off
7 on/7 off
74-132
11.5-30
90-150
11.5-30
11.5-30
16
16
4
8
16
N/A
N/A
N/A
N/A
N/A
IC694TBBx32 or
IC694TBSx32.
Sold Separately.
Terminal Block
(20 screws), included
with module.
Terminal Block
(20 screws), included
with module.
Terminal Block
(20 screws), included
with module.
Terminal Block
(20 screws), included
with module.
90 mA @ 5 VDC
80 mA @ 5 VDC;
125 mA @ 24 VDC
40 mA @ 5 VDC
45 mA @ 5 VDC;
62 mA @ 24 VDC Isolated
Isolated
80 mA @ 5 VDC;
125 mA @ 24 VDC
Isolated
Product Name
Lifecycle Status
Number of Slots Module
Occupies on Backplane
Input Voltage Range
Response Time (ms)
Trigger Voltage
Points per Common
Diagnostic Supported
Connector Type
Intern al Power Used
1.20
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Discrete I/O Modules (Input)
Input modules provide the interface between the PLC and external input devices such as
proximity sensors, push buttons, switches, and BCD thumbwheels. Output modules provide
the interface between the PLC and external output devices such as contactors, interposing
relays, BCD displays and indicator lamps. GE offers a variety of modules that support
different voltage ranges and types, current capacity, isolation and response time to
meet your application needs
IC694MDL646
IC694MDL654
IC694MDL655
IC694MDL660
IC695MDL664
PACSystems RX3i DC
Voltage Input Module,
24 VDC Pos/Neg Logic,
FAST, 16 Point Input
PACSystems RX3i DC
Voltage Input Module,
5/12 VDC (TTL)
Pos/Neg Logic,
32 Point Input
PACSystems RX3i DC
Voltage Input Module,
24 VDC Pos/Neg Logic,
32 Point Input
PACSystems RX3i DC
Voltage Input Module,
24 VDC Pos/Neg Logic,
32 Point Input
PACSystems RX3i DC
Voltage Input Module,
24VDC Positive Logic,
Advanced Diagnostics,
16 Point Input
Active
Active
Active
Active
Active
Module Type
Discrete Input
Discrete Input
Discrete Input
Discrete Input
Discrete Input
Backplane Support
No Backplane
Restrictions
No Backplane
Restrictions
No Backplane
Restrictions
No Backplane
Restrictions
Universal PCI
Slot Only
1
1
1
1
1
0-30 VDC
0-15 VDC
0-30 VDC
0-30 VDC
0-30 VDC
Input Current (mA)
7
3.0 @ 5 V, 8.5 @ 12 V
7
7
12.2
Number of Points
16
32
32
32
16
1 on/1 off
1 on/1 off
2 on/2 off
0.5ms, 1.0ms, 2.0ms,
5ms, 10ms, 50ms and
100ms, selectable per
module. On and off.
0.5ms, 1.0ms, 2.0ms,
5ms, 10ms, 50ms and
100ms, selectable per
module. On and off.
11.5-30
4.2-15
11.5-30
11.5-30
0.5 × VIN VDC
16
8
8
8
8
N/A
N/A
N/A
N/A
Open Wire,
Short to DC Negative
Input Pulse Test
Short to DC Plus
Terminal Block (20 screws),
included with module.
Fujitsu Connector
Fujitsu Connector
Connector Type
IC694TBBx32 or
IC694TBSx32.
Sold Separately.
IC694TBB032 or
IC694TBS032
80 mA @ 5 VDC;
125 mA @ 24 VDC Isolated
5 VDC -195 mA @ 5 VDC;
12 VDC -440 mA @ 5 VDC
195 mA @ 5 VDC
300 mA @ 5 VDC
Internal Power Used
225 mA @ 5 VDC;
95 mA @ 3.3 VDC
Product Name
Lifecycle Status
Number of Slots Module
Occupies on Backplane
Input Voltage Range
Response Time (ms)
Trigger Voltage
Points per Common
Diagnostic Supported
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.21
PACSystems RX3i
Programmable Controllers
Analog I/O Modules (Input)
GE offers easy-to-use analog modules and HART analog modules for control processes such
as flow, temperature and pressure.
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
IC694ALG232
IC694ALG233
IC695ALG600
PACSystems RX3i
Analog Input, Voltage, High Density
(16 Channel) 16 Bit with
advanced diagnostics
PACSystemsRX3i
Analog Input, Current, High Density
(16 Channel) 16 Bit with
advanced diagnostics
PACSystems RX3i Analog Input.
Configurable per channel for Current,
Voltage, RTD, Thermocouple and Resistive.
High Density (8 Channel) Requires High
Density Terminal Block (IC694TBB032 or
IC694TBS032). Cold Junction Compensation
are available for Thermocouple configurations (IC695ACC600 contains 2 CJCs)
Active
Active
Active
Analog Input
Analog Input
Universal Analog Input
No Backplane Restrictions
No Backplane Restrictions
Universal Backplane Only. Uses PCI Bus.
1
1
1
-10 V to +10 V, 0 to 10 V
0-20 mA, 4-20 mA,
4-20 mA Enhanced
Voltage: +50 mV, +150 mV, 0–5 V, 1–5 V,
0–10 V, +10 V; Current: 0–20 mA, 4–20 mA,
+20 mA; Thermocouple Inputs: B, C, E, J, K, N, R,
S, T; RTD Inputs: PT 385 / 3916, N 618 / 672, NiFe
518, CU 426: Resistance Inputs: 0 to 250 / 500 /
1000 / 2000 / 3000 / 4000 Ohms
N/A
N/A
N/A
No
No
Two Groups of Four
Range
HART Support
Channel-to-Channel Isolation
Number of Channels
Update Rate
Resolution
16 Single Ended, 8 Differential
16
8
Single Ended: 5 ms for all channels
Differential: 3 ms all channels
6 ms all channels
10ms per Channel; 4 Channels = 40ms (1KHz
filter) 127ms per Channel 4 Channels = 508ms
(8Hz filter) Channels that are disabled
are not scanned, shortening scan time.
16 bit; ±10 V, 0.3125 mV, 1 LSB;
0-10 V, 0.3125 mV, 1 LSB
16 bit; 0-20 mA, 0.625 @ 181A/bit; 4-20 mA,
0.5 @ 181A/bit; 4-20 mA
Enhanced, 0.5 @181A/bit
11 to 16 bits, depending on configured
range and A/D filter frequency
0.25% at 25ºC (77ºF)
0.25% at 25ºC (77ºF)
Calibrated Accuracy at 25°C.
Better than 0.1% of range (except
10 ohm CU RTD) Accuracy depends
on A/D filter, data format, input noise,
and ambient temperature.
500K Ohms (single-ended mode)
1 MegaOhms (differential mode)
250 ohms
Current 249 ohms ±1%
23 Hz (single-ended mode)
38 Hz (differential mode)
23 Hz
Configurable: 8Hz, 12Hz, 16Hz,
40Hz, 200Hz, 1000Hz
Accuracy
Input Impedance
Input Filter Response
Notch Filter
N/A
N/A
Yes
Diagnostics
Under Range/Over Range,
Positive/Negative Rate of Change, High,
High-High, Low, Low-Low
Under Range/Over Range, Open Wire,
Positive/Negative Rate of Change, High,
High-High, Low, Low-Low
Open Wire, Short Circuit,
Positive/Negative Rate of Change,
High, High-High, Low, Low-Low
112 mA (maximum) @ +5 VDC
120 mA @ +5 VDC
400 mA @ 5 V; 350 mA @ 3.3 V
110 mA (maximum) +24 VDC supply
connected to TB1 on IC695CHSxxx
65 mA @ 24 VDC
N/A
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
IC694TBBx32 or IC694TBSx32.
Sold Separately.
Internal Power Used
External Power Requirement
Connector Type
1.22
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Analog I/O Modules (Input)
GE offers easy-to-use analog modules and HART analog modules for control processes such
as flow, temperature and pressure.
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
IC695ALG608
IC695ALG616
IC695ALG628
PACSystems RX3i Analog Input.
Configurable per channel for Current
or Voltage. High Density (8 Channel)
Requires High Density Terminal Block
(IC694TBB032 or IC694TBS032).
PACSystems RX3i Analog Input.
Configurable per channel for Current
or Voltage. High Density (16 Channel)
Requires High Density Terminal Block
(IC694TBB032 or IC694TBS032).
PACSystems RX3i Analog Input
with HART Communications.
Configurable per channel for Current
or Voltage. High Density (8 Channel)
Requires High Density Terminal Block
(IC694TBB032 or IC694TBS032).
Active
Active
Active
Analog Input
Analog Input
Analog Input with HART Communications
Universal Backplane Only. Uses PCI Bus.
Universal Backplane Only. Uses PCI Bus.
Universal Backplane Only. Uses PCI Bus.
1
1
1
Current: 0 to 20 mA, 4 to 20 mA, ±20 mA;
Voltage: ±10 V, 0 to 10 V, ±5 V, 0 to 5 V, 1 to 5 V
Current: 0 to 20 mA, 4 to 20 mA, ±20 mA;
Voltage: ±10 V, 0 to 10 V, ±5 V, 0 to 5 V, 1 to 5 V
Current: 0 to 20 mA, 4 to 20 mA, ±20 mA;
Voltage: ±10 V, 0 to 10 V, ±5 V, 0 to 5 V, 1 to 5 V
N/A
N/A
Get HART Device Information (Function 1)
Simplified HART Pass-Thru Command (Function 2)
Enterprise HART Pass-Thru Command (Function 3)
One Group of Eight
One Group of Sixteen
One Group of Eight
Range
HART Support
Channel-to-Channel Isolation
Number of Channels
Update Rate
Resolution
Accuracy
Input Impedance
Input Filter Response
8
16
8
All 8 Channels at 5 msec @ 500Hz.
Performance is dependent on filtering.
All 16 Channels at 9 msec @ 500Hz.
Performance is dependent on filtering.
All 8 Channels at 5 msec @ 500Hz.
Performance is dependent on filtering
and HART enabled channels could add
6 to 8 seconds.
32-bit IEEE floating point or 16-bit integer
(in 32-bit field) input data format
32-bit IEEE floating point or 16-bit integer
(in 32-bit field) input data format
Selectable per channel
Calibrated Accuracy @ 13°C – 33°C with
8 Hz, 12 Hz and 16 Hz filter; 0 to 10 V,
±10 V input types: 10 mV0 to 5 V, 1 to 5 V,
±5 V input types: 5 mV0 to 20 mA,
4 to 20 mA, ±20 mA input types: 20 µA
Calibrated Accuracy @ 13°C – 33°C with
8 Hz, 12 Hz and 16 Hz filter; 0 to 10 V,
±10 V input types: 10 mV0 to 5 V, 1 to 5 V,
±5 V input types: 5 mV0 to 20 mA,
4 to 20 mA, ±20 mA input types: 20 µA
Calibrated Accuracy @ 13°C – 33°C
with 8 Hz, 12 Hz and 16 Hz filter;
0 to 10 V, ±10 V input types: 10 mV0 to
5 V, 1 to 5 V, ±5 V input types: 5 mV0 to 20 mA,
4 to 20 mA, ±20 mA input types: 20 µA
Current 249 ohms ±1%
Current 249 ohms ±1%
Current 249 ohms ±1%
Configurable: 8Hz, 12Hz, 16Hz,
40Hz, 200Hz, 500Hz
Configurable: 8Hz, 12Hz, 16Hz,
40Hz, 200Hz, 500Hz
Configurable: 8Hz, 12Hz, 16Hz,
40Hz, 200Hz, 500Hz
Notch Filter
Yes
Yes
Yes
Diagnostics
Open wire, short circuit, positive/negative rate
of change, High, High-High, Low, Low-Low
Open wire, short circuit, positive/negative rate
of change, High, High-High, Low, Low-Low
Open wire, short circuit, positive/negative rate
of change, High, High-High, Low, Low-Low
450 mA @ 5 V; 600 mA @ 3.3 V
450 mA @ 5 V; 600 mA @ 3.3 V
450 mA @ 5 V; 600 mA @ 3.3 V
N/A
N/A
N/A
IC694TBBx32, IC694TBSx32 or IC694TBC032
Sold Separately.
IC694TBBx32, IC694TBSx32 or IC694TBC032
Sold Separately.
IC694TBBx32 or IC694TBSx32.
Sold Separately.
Internal Power Used
External Power Requirement
Connector Type
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.23
PACSystems RX3i
Programmable Controllers
Analog I/O Modules (Input)
GE offers easy-to-use analog modules and HART analog modules for control processes
such as flow, temperature and pressure.
IC695ALG626
IC695ALG106
IC695ALG112
Product Name
PACSystems RX3i Analog Input
with HART Communications.
Configurable per channel for Current
or Voltage. High Density (16 Channel)
Requires High Density Terminal Block
(IC694TBB032 or IC694TBS032).
PACSystems RX3i Isolated Analog Input
Configurable per channel for Current
or Voltage. High Density
(6 Isolated Channels)
Requires High Density Terminal Block
(IC694TBB032 or IC694TBS032).
PACSystems RX3i Isolated Analog Input.
Configurable per channel for Current or
Voltage. High Density (12 Isolated Channels)
Requires High Density Terminal Block
(IC694TBB032 or IC694TBS032).
Lifecycle Status
Active
Active
Active
Analog Input with HART Communications
Analog Input with Channel
to Channel Isolation
Analog Input with Channel
to Channel Isolation
Universal Backplane Only. Uses PCI Bus.
Universal Backplane Only. Uses PCI Bus.
Universal Backplane Only.
Uses PCI Bus.
1
1
1
Current: 0 to 20 mA, 4 to 20 mA, ±20 mA;
Voltage: ±10 V, 0 to 10 V, ±5 V, 0 to 5 V, 1 to 5 V
Current: 0 to 20 mA, 4 to 20 mA, ±20 mA;
Voltage: ±10 V, 0 to 10 V, ±5 V, 0 to 5 V, 1 to 5 V
Current: 0 to 20 mA, 4 to 20 mA, ±20 mA;
Voltage: ±10 V, 0 to 10 V, ±5 V, 0 to 5 V, 1 to 5 V
Get HART Device Information (Function 1)
Simplified HART Pass-Thru Command (Function 2)
Enterprise HART Pass-Thru Command (Function 3)
N/A
N/A
One Group of Sixteen
Yes (250 VAC continuous, 1500 VAC for 1
minute per channel)
Yes (250 VAC continuous, 1500 VAC
for 1 minute per channel)
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Range
HART Support
Channel-to-Channel Isolation
Number of Channels
Update Rate
Resolution
Accuracy
Input Impedance
Input Filter Response
16
6
12
All 16 Channels at 9 msec @ 500Hz.
Performance is dependent on filtering
and HART enabled channels could add
6 to 8 seconds.
1 ms for all channels.
1 ms for all channels
32-bit IEEE floating point or 16-bit integer
(in 32-bit field) input data format
32-bit IEEE floating point or 16-bit integer
(in 32-bit field) input data format
32-bit IEEE floating point or 16-bit integer
(in 32-bit field) input data format
Calibrated Accuracy @ 13°C – 33°C with 8 Hz,
12 Hz and 16 Hz filter; 0 to 10 V, ±10 V input :
types 10 mV0 to 5 V, 1 to 5 V, ±5 V input
types: 5 mV0 to 20 mA, 4 to 20 mA, ±20 mA
input types: 20 µA
±0.1% of span at 25°C, ±0.25%
of span over operating temperature range
±0.1% of span at 25ºC, ±.25% of span
over operating temperature range
Current 249 ohms ±1%
Current = 250 ohms ±1%,
Voltage >= 500k Ohms
Current = 250 ohms ±1%,
Voltage >= 500k Ohms
Configurable: 8Hz, 12Hz, 16Hz,
40Hz, 200Hz, 500Hz
Configurable low-pass: 8Hz, 12Hz, 16Hz,
40Hz, 250Hz, and 1000Hz
Configurable: 8Hz, 12Hz, 16Hz,
40Hz, 250Hz, and 1000Hz
Notch Filter
Yes
N/A
N/A
Diagnostics
Open wire, short circuit, positive/negative rate
of change, High, High-High, Low, Low-Low
Open wire, under range, over range,
positive/negative rate of change, High,
High-High, Low, Low-Low
Open wire, under range, over range,
positive/negative rate of change,
High, High-High, Low, Low-Low
450 mA @ 5 V; 600 mA @ 3.3 V
400 mA @ 5 V; 600 mA @ 3.3 V
800 mA @ 5 V; 600 mA @ 3.3 V
N/A
19.2 V to 30 VDC, Current required: 500 mA
19.2 V to 30 VDC,
Current required: 500 mA
IC694TBBx32 or IC694TBSx32.
Sold Separately.
IC694TBBx32 or IC694TBSx32.
Sold Separately.
IC694TBBx32 or IC694TBSx32.
Sold Separately.
Internal Power Used
External Power Requirement
Connector Type
1.24
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Analog I/O Modules (Input)
GE offers easy-to-use analog modules and HART analog modules for control processes such
as flow, temperature and pressure.
IC694ALG220
IC694ALG221
IC694ALG222
IC694ALG223
PACSystems RX3i Analog Input,
Voltage, 4 Channel
PACSystems RX3i
Analog Input, Current,
4 Channel
PACSystems RX3i
Analog Input,Voltage,
High Density (16 Channel)
PACSystems RX3i
Analog Input, Input,
Current, High Density
(16 Channel)
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Range
Active
Active
Active
Active
Analog Input
Analog Input
Analog Input
Analog Input
No Backplane Restrictions
No Backplane Restrictions
No Backplane Restrictions
No Backplane Restrictions
1
1
1
1
-10 V to +10 V
4-20 mA, 0-20 mA
-10 V to ±10 V, 0 to 10 V
0-20 mA, 4-20 mA
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4
4
1
16
4 ms all channels
2 ms all channels
13 ms all channels
13 ms all Channels
12 bit; 5 mV/20 µA/bit
12 bit; 0-20 mA, 5 µA/bit;
4-20 mA, 4 µA/bit
12 bit; ±10 V, 5 mV/20 µA/bit;
0-10 V, 5 mV/20 µA/bit
12 bit; 0-20 mA, 5 µA/bit;
4-20 mA, 4 µA/bit; 4-20 mA
Enhanced, 5µA/bit
±10 mV/40µA at 25ºC (77ºF)
0.1 % full scale
0.25% at 25ºC (77ºF)
0.25% at 25ºC (77ºF)
>9 Megohms
250 ohms
250 ohms
250 ohms
17 Hz
325 Hz
200 Hz
200 Hz
HART Support
Channel-to-Channel Isolation
Number of Channels
Update Rate
Resolution
Accuracy
Input Impedance
Input Filter Response
Notch Filter
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
27 mA @ 5 VDC; 98 mA @
24 VDC Isolated
25 mA @ 5 VDC; 100 mA @
24 VDC Isolated
112 mA @ 5 VDC; 4150 mA- User
Supplied 24 VDC
120 mA @ 5 VDC; 65 mA-User
Supplied 24 VDC
N/A
N/A
N/A
N/A
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Diagnositics
Internal Power Used
External Power Requirement
Connector Type
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.25
PACSystems RX3i
Programmable Controllers
Analog I/O Modules (Input)
GE offers easy-to-use analog modules for control processes such as flow, temperature
and pressure.
HE693ADC410
HE693ADC420
Product Name
Isolated Analog Input Module,
Voltage, 1500 VAC, Isolation
Isolated Analog Input Module,
Current, 1500 VAC, Isolation
Lifecycle Status
Active
Active
Analog Input
Analog Input
No Backplane Restrictions
No Backplane Restrictions
1
1
±10 V
4-20 mA, ±20 mA
4
4
1500 VAC (RMS), ±2000 VDC
1500 VAC (RMS), ±2000 VDC
1 Megohm
100 ohms
Integrating, 18 bits
Integrating, 18 bits
13 bits plus sign
13 bits plus sign
I/O Required
4 %AI, 4 %AQ, 16 %I
8 %AI, 8 %AQ, 16 %I
Sample Rate
45 channels/second
45 channels/second
Analog Filtering
1 KHz, 3 pole Bessel
1 KHz, 3 pole Bessel
Digital Filtering
1-128 samples/update
1-128 samples/update
Maximum Error
.05% full scale
.05% full scale
1500 VAC (RMS), ±2000 VDC
1500 VAC (RMS), ±2000 VDC
Common Mode Rejection
>100 dB
>100 dB
Power Consumption at
Steady State, Maximum
.7 W @ 5 V, 1.2 W @ 24 V
.7 W @ 5 V, 1.2 W @ 24 V
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
N/A
N/A
140 mA @ 5 VDC; 50 mA @ 24 VDC Relay
140 mA @ 5 VDC; 50 mA @ 24 VDC Relay
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Range
Number of Channels
Channel-to-Channel Isolation
Input Impedance
A/D Type, Resolution
Useable Resolution
Common Mode Range
Connector Type
External Power Requirement
Internal Power Used
1.26
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Discrete I/O Modules (Output)
Input modules provide the interface between the PLC and external input devices such as
proximity sensors, push buttons, switches, and BCD thumbwheels. Output modules provide
the interface between the PLC and external output devices such as contactors, interposing
relays, BCD displays and indicator lamps. GE offers a variety of modules that support
different voltage ranges and types, current capacity, isolation and response time to
meet your application needs.
IC694MDL310
IC694MDL330
IC694MDL340
IC694MDL390
PACSystems RX3i AC
Voltage Output Module,
120 VAC,
0.5A, 12 Point Output
PACSystems RX3i AC
Voltage Output Module,
120/240 VAC,
1A, 8 Point Output
PACSystems RX3i AC
Voltage Output Module,
120 VAC,
0.5A, 16 Point Output
PACSystems RX3i AC
Voltage Output Module,
120/240 VAC Isolated,
2A, 5 Point Output
Active
Active
Active
Active
Discrete Output
Discrete Output
Discrete Output
Discrete Output
No Backplane Restrictions
No Backplane Restrictions
No Backplane Restrictions
No Backplane Restrictions
1
1
1
1
85-132 VAC
85-264 VAC
85-132 VAC
85-264 VAC
Number of Points
12
8
16
5
Isolation
N/A
N/A
N/A
Yes
N/A
N/A
N/A
N/A
0.5 A
1A
0.5 A
2:00 AM
1 on 1/2 cy off
1 on 1/2 cy off
1 on 1/2 cy off
1 on 1/2 cy off
Output Type
Triac
Triac
Triac
Triac
Polarity
N/A
N/A
N/A
N/A
6
4
4
1
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
210 mA @ 5 VDC
160 mA @ 5 VDC
315 mA @ 5 VDC
110 mA @ 5 VDC
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Output Voltage Range
Diagnostics
Load Current
per Point
Response Time (ms)
Points per Common
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.27
PACSystems RX3i
Programmable Controllers
Discrete I/O Modules (Output)
Input modules provide the interface between the PLC and external input devices such as
proximity sensors, push buttons, switches, and BCD thumbwheels. Output modules provide
the interface between the PLC and external output devices such as contactors, interposing
relays, BCD displays and indicator lamps. GE offers a variety of modules that support
different voltage ranges and types, current capacity, isolation and response time to
meet your application needs.
IC694MDL350
IC694MDL732
IC694MDL734
IC694MDL740
PACSystems RX3i AC
Voltage Output Module,
120/240 VAC Isolated,
2A, 16 Point Output
PACSystems RX3i DC
Voltage Output Module,
12/24 VDC Positive Logic,
0.5A, 8 Point Output
PACSystems RX3i DC
Voltage Output Module,
125 VDC Pos/Neg Logic,
6 Point Output
PACSystems RX3i DC
Voltage Output Module,
12/24 VDC Positive Logic,
0.5A, 16 Point Output
Active
Active
Active
Active
Discrete Output
Discrete Output
Discrete Output
Discrete Output
No Backplane Restrictions
No Backplane Restrictions
No Backplane Restrictions
No Backplane Restrictions
1
1
1
1
74-264 VAC
12-24 VDC
11-150 VDC
12-24 VDC
Number of Points
16
8
6
16
Isolation
Yes
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Per Point 2A max. @ 30°C & 1A
max. @ 60°C (Linear derating)
0.5 A
1A
0.5 A
1 on 1/2 cy off
2 on/2 off
7 on/5 off
2 on/2 off
Output Type
Triac
Transistor
Transistor
Transistor
Polarity
N/A
Positive
Positive/Negative
Positive
1
8
1
8
IC694TBBx32 or IC694TBSx32.
Sold Separately.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
110 mA @ 5 VDC
50 mA @ 5 VDC
90 mA @ 5 VDC
110 mA @ 5 VDC
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Output Voltage Range
Diagnostics
Load Current
per Point
Response Time (ms)
Points per Common
Connector Type
Internal Power Used
1.28
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Discrete I/O Modules (Output)
Input modules provide the interface between the PLC and external input devices such as
proximity sensors, push buttons, switches, and BCD thumbwheels. Output modules provide
the interface between the PLC and external output devices such as contactors, interposing
relays, BCD displays and indicator lamps. GE offers a variety of modules that support
different voltage ranges and types, current capacity, isolation and response time to
meet your application needs.
IC694MDL741
IC694MDL742
IC694MDL752
IC694MDL753
PACSystems RX3i DC
Voltage Output Module,
12/24 VDC Negative Logic,
0.5A, 16 Point Output
PACSystems RX3i DC
Voltage Output Module,
12/24 VDC Positive Logic ESCP,
1A, 16 Point Output
PACSystems RX3i DC
Voltage Output Module,
5/24 VDC (TTL) Negative Logic,
0.5A, 32 Point Output
PACSystems RX3i DC
Voltage Output Module,
12/24 VDC Positive Logic,
0.5A, 32 Point Output
Active
Active
Active
Active
Discrete Output
Discrete Output
Discrete Output
Discrete Output
No Backplane Restrictions
No Backplane Restrictions
No Backplane Restrictions
No Backplane Restrictions
1
1
1
1
12-24 VDC
12-24 VDC
5, 12-24 VDC
12-24 VDC
Number of Points
16
16
32
32
Isolation
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0.5 A
1A
0.5 A
0.5 A
2 on/2 off
2 on/2 off
0.5 on/0.5 off
0.5 on/0.5 off
Output Type
Transistor
Transistor
Transistor
Transistor
Polarity
Negative
Positive
Negative
Positive
8
8
8
8
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Fujitsu Connector
Fujitsu Connector
110 mA @ 5 VDC
130 mA @ 5 VDC
260 mA @ 5 VDC
260 mA @ 5 VDC
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Output Voltage Range
Diagnostics
Load Current
per Point
Response Time (ms)
Points per Common
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.29
PACSystems RX3i
Programmable Controllers
Discrete I/O Modules (Output)
Input modules provide the interface between the PLC and external input devices such as
proximity sensors, push buttons, switches, and BCD thumbwheels. Output modules provide
the interface between the PLC and external output devices such as contactors, interposing
relays, BCD displays and indicator lamps. GE offers a variety of modules that support
different voltage ranges and types, current capacity, isolation and response time to
meet your application needs.
IC694MDL754
IC695MDL765
IC694MDL930
IC694MDL916
IC694MDL931
Product Name
PACSystems RX3i DC
Voltage Output Module,
12/24 VDC Positive Logic
with ESCP (Self Healing),
0.75A, 32 Point Output
RX3i DC Voltage Output
Module, 24/125 volt DC 2A
Smart Digital Output
module, 16 Point Output
PACSystems RX3i AC/DC
Voltage Output Module,
Relay, N.O., 4A Isolated,
8 Point Output
PACSystems RX3i AC/DC
Voltage Output Module,
Relay, N.O., 4A Isolated,
16 Point Output
PACSystems RX3i AC/DC
Voltage Output Module,
Relay, N.C. and Form C,
8A Isolated, 8 Point Output
Lifecycle Status
Active
Active
Active
Active
Active
Discrete Output
Discrete Output
Discrete Output
Discrete Output
Discrete Output
No Backplane Restrictions
Universal Backplane Only.
Uses PCI Bus.
No Backplane Restrictions
No Backplane Restrictions
No Backplane Restrictions
1
1
1
1
1
12-24 VDC
18 to 30VDC
105 to 132 VDC
0 to 125 VDC,
5/24/125 VDC nominal 0
to 265 VAC (47 to 63 Hz),
120/240 VAC nominal
5 to 125 VDC
5/24/125 VDC nominal
5 to 250 VAC (47 to 63 Hz),
120/240 VAC nominal
0 to 125 VDC,
5/24/125 VDC nominal 0
to 265 VAC (47 to 63 Hz),
120/240 VAC nominal
Number of Points
32
16
8
16
8
Isolation
N/A
N/A
Yes
Yes
Yes
Short Circuit Detection
• Output Pulse Test
• Over temperature
• Failed Switch Detection
• Overload Detection
and Shutdown
• No-load Detection
N/A
N/A
N/A
0.75 A
2A
2A
4A
8A
0.5 on/0.5 off
1 msec maximum
15 on/15 off
10ms maximum
(At nominal voltage
excluding contact bounce)
15 on/15 off
Transistor
Transistor
Relay
Relay
Relay
Positive
Positive
N/A
N/A
N/A
16
16
1
1
1
IC694TBBx32 or
IC694TBSx32.
Sold Separately.
IC694TBBx32 or
IC694TBSx32.
Sold Separately.
Terminal Block (20 screws),
included with module.
IC694TBBx32 or
IC694TBSx32.
Sold Separately.
Terminal Block (20 screws),
included with module.
300 mA @ 5 VDC
540 mA @ 5.1 VDC;
152 mA @ 3.3 VDC
6 mA @ 5 VDC;
70 mA @ 24 VDC Relay
300 mA @ 5 VDC from
backplane maximum
(all outputs ON)
6 mA @ 5 VDC;
110 mA @ 24 VDC Relay
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Output Voltage Range
Diagnostics
Load Current
per Point
Response Time (ms)
Output Type
Polarity
Points per Common
Connector Type
Internal Power Used
1.30
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Discrete I/O Modules (Output)
Input modules provide the interface between the PLC and external input devices such as
proximity sensors, push buttons, switches, and BCD thumbwheels. Output modules provide
the interface between the PLC and external output devices such as contactors, interposing
relays, BCD displays and indicator lamps. GE offers a variety of modules that support
different voltage ranges and types, current capacity, isolation and response time to
meet your application needs.
IC694MDL940
HE693RLY100
HE693RLY110
PACSystems RX3i AC/DC
Voltage Output Module,
Relay, N.O., 2A,
16 Point Output
DC/AC Voltage Relay
Output Module
High Current
DC/AC Voltage Relay
Output Module
High Current (fused)
Active
Active
Active
Discrete Output
Discrete Output
Discrete Output
No Backplane Restrictions
No Backplane Restrictions
No Backplane Restrictions
1
1
1
0 to 125 VDC,
5/24/125 VDC nominal 0
to 265 VAC (47 to 63 Hz),
120/240 VAC nominal
12-120 VAC, 12-30 VDC
12-120 VAC, 12-30 VDC
Number of Points
16
8
8
Isolation
N/A
N/A
Yes
N/A
N/A
N/A
2A
8A
8A
15 on/15 off
11 on/11 off
11 on/11 off
Relay
Relay
Relay
N/A
N/A
N/A
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Output Voltage Range
Diagnostics
Load Current
per Point
Response Time (ms)
Output Type
Polarity
Points per Common
Connector Type
Internal Power Used
www.ge-ip.com
4
N/A
1
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
7 mA @ 5 VDC;
135 mA @ 24 VDC Relay
180 mA @ 5 VDC;
200 mA @ 24 VDC Relay
180 mA @ 5 VDC;
200 mA @ 24 VDC Relay
GE Intelligent Platforms Control Systems Solutions
1.31
PACSystems RX3i
Programmable Controllers
Analog I/O Modules (Output)
GE offers easy-to-use analog modules for control processes such as flow, ­temperature
and pressure.
IC694ALG392
IC695ALG704
Product Name
PACSystems RX3i Analog Output,
Current/Voltage, 8 Channel
PACSystems RX3i Analog Output,
Current/Voltage, 4 Channel
Lifecycle Status
Active
Active
Analog Output
Analog Output
No Backplane Restrictions
Universal Backplane Only.
Uses PCI Bus.
1
1
N/A
High and Low Alarm, Ramp Rate
Control Clamping, Overrange
and Underrange
Reverse polarity and undervoltage
on external power supply
N/A
0 V to +10 V, -10 V to +10 V,
0-20 mA, 4-20 mA
Current: 0 to 20 mA, 4 to 20 mA;
Voltage: ±10 V, 0 to 10 V
N/A
N/A
8
4
N/A
N/A
8 ms all channels
8 ms all channels
16 bit; 0.312 mV/bit
±10 V: 15.9 bits; 0 to 10 V: 14.9 bits;
0 to 20 mA: 15.9 bits; 4 to 20 mA: 15.6 bits
0-20 mA, 4-20 mA ±0.1% at 25ºC (77ºF);
0-10 V, -10F + 10 V ±0.25 at 25ºC (77ºF)
Accurate to within 0.15% of full scale
at 25°C. Accurate to within 0.30%
of full scale at 60°C
5 mA (2 K ohms)
Current -850ohm max @ Vuser = 20 V;
Voltage -2k ohm max load
(minimum resistance)
2000 pF, Inductance 1H
Current: 10uH max.; Voltage: 1uF max.
N/A
Voltage Range: 19.2 V to 30 V
Current required: 160 mA
Terminal Block (20 screws),
included with module.
IC694TBB032 or IC694TBS032.
Sold Separately.
110 mA @ 5 VDC;
315 mA -User Supplied 24 VDC
375 mA @3.3 V (internal)
160 mA @24 V (external)
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Diagnostics
Protection
Range
HART Support
Number of Channels
Channel-to-Channel Isolation
Update Rate
Resolution
Accuracy
Maximum Output Load
Output Load Capacitance
External Power Requirement
Connector Type
Internal Power Used
1.32
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Analog I/O Modules (Output)
GE offers easy-to-use analog modules for control processes such as flow, ­temperature
and pressure.
IC695ALG708
IC695ALG728
Product Name
PACSystems RX3i Analog Output,
Current/Voltage, 8 Channel
PACSystems RX3i Analog Output
with HART Communications,
Current/Voltage, 8 Channel
Lifecycle Status
Active
Active
Analog Output
Analog Output with HART Communications
Universal Backplane Only.
Uses PCI Bus.
Universal Backplane Only.
Uses PCI Bus.
1
1
High and Low Alarm, Ramp Rate
Control Clamping, Overrange
and Underrange
High and Low Alarm, Ramp Rate Control,
Clamping, Overrange and Underrange
N/A
N/A
Current: 0 to 20 mA, 4 to 20 mA;
Voltage: ±10 V, 0 to 10 V
Current: 0 to 20 mA, 4 to 20 mA;
Voltage: ±10 V, 0 to 10 V
N/A
-Get HART Device Information (Function 1)
Simplified HART Pass-Thru Command (Function 2)
-Enterprise HART Pass-Thru Command (Function 3)
8
8
N/A
N/A
8 ms all channels
8 ms all channels and HART enabled
channels could add 6 to 8 seconds.
10 V: 15.9 bits; 0 to 10 V: 14.9 bits;
0 to 20 mA: 15.9 bits; 4 to 20 mA: 15.6 bits
±10 V: 15.9 bits; 0 to 10 V: 14.9 bits;
0 to 20 mA: 15.9 bits; 4 to 20 mA: 15.6 bits
Accurate to within 0.15% of full scale
at 25°C. Accurate to within 0.30%
of full scale at 60°C
Accurate to within 0.15% of full scale at 25°C.
Accurate to within 0.30% of full scale at 60°C
Current -850ohm max @ Vuser = 20 V;
Voltage -2k ohm max load
(minimum resistance)
Current -850ohm max @ Vuser = 20 V;
Voltage -2k ohm max load
(minimum resistance)
Current: 10uH max.; Voltage: 1uF max.
Current: 10uH max.;
Voltage: 1uF max.
External Power Requirement
Voltage Range: 19.2 V to 30 V
Current required: 315 mA
Voltage Range: 19.2 V to 30 V
Current required: 315 mA
Connector Type
IC694TBB032 or IC694TBS032.
Sold Separately
IC694TBB032 or IC694TBS032.
Sold Separately.
375 mA @3.3 V (internal)
315 mA @24 V (external)
375 mA @3.3 V (internal)
315 [email protected] V (external)
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Diagnostics
Protection
Range
HART Support
Number of Channels
Channel-to-Channel Isolation
Update Rate
Resolution
Accuracy
Maximum Output Load
Output Load Capacitance
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.33
PACSystems RX3i
Programmable Controllers
Analog I/O Modules (Output)
GE offers easy-to-use analog modules for control processes such as flow, ­temperature
and pressure.
IC695ALG808
IC694ALG390
IC694ALG391
Product Name
PACSystems RX3i Isolated Analog Output,
Current/Voltage, 8 Isolated Channels
PACSystems RX3i Analog Output,
Voltage, 2 Channel
PACSystems RX3i Analog Output,
Current, 2 Channel
Lifecycle Status
Active
Active
Active
Analog Output with Channel to Channel Isolation
Analog Output
Analog Output
Universal Backplane
Only. Uses PCI Bus.
No Backplane Restrictions
No Backplane Restrictions
1
1
1
High and Low Alarm, Ramp Rate Control,
Clamping, Overrange and Underrange
N/A
N/A
N/A
N/A
N/A
Current: 0 to 20 mA, 4 to 20 mA;
Voltage: ±10 V, 0 to 10 V
-10 V to +10 V, 4-20 mA
1-5 V and 0-5 V, 0-20 mA,
4-20 mA
N/A
N/A
N/A
8
2
2
Yes (250 VAC continuous,
1500 VAC for 1 minute per channel)
N/A
N/A
8 ms all channels (1 msec per channel)
5 ms all channels
5 ms all channels
±10 V @ 15.9 bits minimum
0 to 10 V @ 14.9 bits minimum
0 to 20 mA @ 15.9 bits minimum
4 to 20 mA @ 15.6 bits minimum
12 bit; 2.5 mV/bit
12 bit;0-20 mA, 5µA/bit
Resolution
Accurate to within ±0.1% of span
at 25C, ± 0.25% of span over operating
temperature range
±5 mV at 25ºC (77ºF)
Accuracy
0-20 mA, ±8 µA at 25ºC (77ºF);
0-20 mA, 4-20 mA ±0.1%
at 25ºC (77ºF)
Current: 1350 ohm maximum resistance,
10uH max inductance
Voltage: 2k Ohm minimum resistance,
1uF max capacitance
5 mA (2 K ohms)
5 mA (2 K ohms)
Current: 10uH max.;
Voltage: 1uF max.
2000 pF
2000 pF, Inductance 1H
500 mA @ 24 VDC
N/A
N/A
IC694TBBx32 or IC694TBSx32
Sold Separately.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
450 mA @ 3.3 V Maximum,
all channels on
32 mA @ 5 VDC;
120 mA @ 24 VDC Isolated
30 mA @ 5 VDC;
215 mA 24 VDC Isolated
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Diagnostics
Protection
Range
HART Support
Number of Channels
Channel-to-Channel Isolation
Update Rate
Maximum Output Load
Output Load Capacitance
External Power Requirement
Connector Type
Internal Power Used
1.34
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Analog I/O Modules (Output)
GE offers easy-to-use analog modules for control processes such as flow, ­temperature
and pressure.
HE693DAC410
HE693DAC420
Product Name
Isolated Analog Output
Module, Voltage
Isolated Analog Output
Module, Current
Lifecycle Status
Active
Active
Analog Output
Analog Output
No Backplane Restrictions
No Backplane Restrictions
1
1
N/A
N/A
N/A
N/A
±10 V
4-20 mA or 0-20 mA
N/A
N/A
4
4
1500 VAC (RMS), ±2000 VDC
1500 VAC (RMS), ±2000 VDC
N/A
N/A
1.2 5 mV
2.0 µA (4-20 mA); 2.5 µA (±20 mA)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
2-32 VDC
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
500 mA @ 5 VDC;
150 mA @ 24 VDC Relay
150 mA @ 5 VDC;
110 mA @ 24 VDC Relay
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Diagnostics
Protection
Range
HART Support
Number of Channels
Channel-to-Channel Isolation
Update Rate
Resolution
Accuracy
Maximum Output Load
Output Load Capacitance
External Power Requirement
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.35
PACSystems RX3i
Programmable Controllers
Analog Mixed I/O Modules (Input and Output)
The analog mixed modules (four in and two out) are available with or without advanced
diagnostics. The advanced diagnostics includes alarms, open wire, rate of change, over
range and under range. Additional features include 16 bit resolution, analog output clamp
limits and output ramp mode option.
IC694ALG542
IC694ALG442
Active
Active
Analog Combination 4 In and 2 Out with Advanced Diagnostics,
Output Clamp and Ramp Control
Analog Combination 4 In and 2 Out
No Backplane Restrictions
No Backplane Restrictions
1
1
0 V to +10 V, -10 V to +10 V, 0-20 mA, 4-20 mA per Channel
0 V to +10 V, -10 V to +10 V, 0-20 mA, 4-20 mA per Channel
N/A
N/A
4 in/2 out
4 in/2 out
2ms all channels
2ms all channels
Resolution
(Input)16 bit; 0 V to 10 V, 0.3125 mV/bit; -10 V to +10 V,
0.3125 mV/bit; 0-20 mA, 0.625 µA 4-20 mA 0.5 µA/bit (Output) 16 bit;
0 to 20 mA: 0.625 µA; 4 to 20 mA: 0.5 µA; –10 V to +10 V: 0.3125 mV;
0 to +10 V: 0.3125 mV
(Input)12 bit; 0 V to 10 V, 2.5 mV/bit; -10 V to +10 V, 5 mV/bit;
0-20 mA,4-20 mA 5&#0181A/bit (Output) 16 bit; 0.312 mV/bit;
4-20 mA 0.5 &#0181A/bit; 0-20 mA 0.625 &#0181A/bit
(Input) 0.25 % at 25&#0176C (77&#0176F) (Output)
0-20 mA, 4-20 mA ±0.1% at 25&#0176C (77&#0176F)
Accuracy
Current Input 0 to 20mA ±0.25% of full scale @25°C (77°F); ±0.5% of
full scale over specified operating temperature range Current Input
4 to 20mA ±0.25% of full scale @25°C (77°F); ±0.5% of full scale over
specified operating temperature range 4 to 20ma Enhanced Mode
±0.25% of full scale @25°C (77°F); ±0.5% of full scale over specified
operating temperature range Current Output ±0.1% of full scale
@ 25°C (77°F), typical ±0.25% of full scale @ 25°C (77°F), maximum
±0.5% of full scale over operating temperature range (maximum)
Voltage Output ±0.25% of full scale @ 25°C (77°F), typical ±0.5% of
full scale @ 25°C (77°F), maximum ±1.0% of full scale
over operating temperature range (maximum)
Current mode - 250 ohms
Voltage mode - 800 K ohms
Current mode - 250 ohms
Voltage mode - 800 K ohms”
Current mode - 55 Hz Voltage mode - 55 Hz
Current mode - 38 Hz Voltage mode - 38 Hz
Voltage: 5 mA (2 K ohms)
Current Inductance:1 H (maximum)
Voltage: 5 mA (2 K ohms)
Current Inductance:1 H (maximum) “
Voltage:1 µF (maximum)
Current: 2000 pF (maximum)
Voltage:1 µF (maximum)
Current: 2000 pF (maximum)”
Under Range/Over Range, Open Wire, Short Circuit,
Positive/Negative Rate of Change,
High, High-High, Low, Low-Low
N/A
Internal Power Used
95 mA @ 5 VDC; 150 mA external 24 VDC Isolated
95 mA @ 5 VDC; 150 mA external 24 VDC Isolated
External Power Requirement
24VDC: Current: 5 µA/V (typical), 10 µA/V (maximum)
Voltage: 25 mV/V (typical), 50 mV/V (maximum)
24VDC: Current: 5 µA/V (typical), 10 µA/V (maximum)
Voltage: 25 mV/V (typical), 50 mV/V (maximum)
Terminal Block (20 screws), included with module.
Terminal Block (20 screws), included with module.
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Range
Channel-to-Channel Isolation
Number of Channels
Update Rate
Input Impedence
Input Filter Response
Maximum Output Load
Output Load Capacitance
Diagnostics
Connector Type
1.36
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Millivolt I/O Modules
The Millivolt Input Modules allow Millivolt level signals, such as bridged strain gages
(load cells) to be directly connected to the PLC without external signal processing
(transducers, transmitters, etc.) All analog and digital processing of the signal is
performed on the module.
IC695ALG600 Millivolt
IC695ALG306 Millivolt
Product Name
Universal Analog and configurable for Current, Voltage, RTD,
Thermocouple and Resistive. High Density (8 Channel) Requires
Cold Junction Compensation; are available for Thermocouple
configurations (IC695ACC600 contains 2 CJCs)
Isolated Thermocouple Input module provides six isolated
differential thermocouple input channels. Each channel can
be individually configured for inputs from: Thermocouple types: J,
K, T, E, R, S, B, N, or C and Voltage: ±150mV or ±50mV.
Lifecycle Status
Active
Active
Millivolt Input
Strain Gage Input
Universal Backplane Only. Uses PCI Bus.
Universal Backplane Only. Uses PCI Bus.
1
1
±150mV or ±50mV
±150mV or ±50mV
Open wire, Short Circuit, Positive/Negative Rate of Change,
High, High-High, Low, Low-Low
Open wire, Short Circuit, Positive/Negative Rate of Change,
High, High-High, Low, Low-Low
Two Groups of Four
250 VAC Continuous
1500 VAC 1 minute
2550 VDC 1 second
8
6
Notch Filter
Yes
From 2.3 Hz to 28 Hz per channel
Resolution
32-bit IEEE floating point or 16-bit integer (in 32-bit field)
input data format)
32-bit IEEE floating point or 16-bit integer (in 32-bit field)
input data format)
Accuracy
Calibrated Accuracy at 25°C. Better than 0.1% of range.
Accuracy depends on A/D filter, data format, input noise,
and ambient temperature.
±0.1% of voltage span at 25°C. ±0.25% of span
over temperature range.
>1M ohm
Voltage: >=500k ohm
N/A
N/A
A/D Conversion Type
Sigma Delta
Sigma Delta
15 msec @ 28 Hz to 120 msec @ 2.3 Hz
A/D Conversion Time
(Assumes 2 ADC’s running in parallel, no CJC or lead resistance)
10ms per Channel 4 Channels = 40ms (1KHz filter) 127ms per
Channel 4 Channels = 508ms (8Hz filter) Channels that are
disabled are not scanned, shortening scan time.
Strain Gages Supported
Yes
Yes
Maximum Normal Voltage Input
N/A
N/A
±14.5 VDC continuous
N/A
IC694TBBx32, IC694TBSx32 or IC694TBC032. Sold Separately.
IC694TBBx32, IC694TBSx32 or IC694TBC032. Sold Separately.
400 mA @ 5 V; 350 mA @ 3.3 V
150 mA @ 5V; 400 mA @ 3.3V
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Range
Diagnostics
Channel-to-Channel Isolation
Number of Channels
Input Impedance
I/O Required
Maximum Voltage Input
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.37
PACSystems RX3i
Programmable Controllers
Millivolt I/O Modules
The Millivolt Input Modules allow Millivolt level signals, such as bridged strain gages
(load cells) to be directly connected to the PLC without external signal processing
(transducers, transmitters, etc.) All analog and digital processing of the signal is
performed on the module.
IC695ALG312 Millivolt
HE693ADC409
Isolated Thermocouple Input module provides twelve isolated
differential thermocouple input channels. Each channel can
be individually configured for inputs from: Thermocouple types: J,
K, T, E, R, S, B, N, or C and Voltage: ±150mV or ±50mV.
Analog I/O Module, Millivolt Input
Product Name
Lifecycle Status
Active
Active
Strain Gage Input
Millivolt Input
Universal Backplane Only. Uses PCI Bus.
No Backplane Restrictions
1
1
±150mV or±50mV
±25 mV, ±50 mV and ±100 mV
Open wire, Short Circuit, Positive/Negative Rate of Change,
High, High-High, Low, Low-Low
N/A
250 VAC Continuous
1500 VAC 1 minute
2550 VDC 1 second
N/A
12
4
Notch Filter
From 2.3 Hz to 28 Hz per channel
N/A
Resolution
32-bit IEEE floating point or 16-bit integer
(in 32-bit field) input data format
3 µV, 6µV, 9µV (respectively)
±0.1% of voltage span at 25ºC
±0.25% of span over temperature range.
±0.5%
Voltage: >=500k ohm
>20 Mohms
N/A
4% AI
Sigma Delta
Integrating
15 msec @ 28 Hz to 120 msec @ 2.3 Hz
35 Channels/second
Strain Gages Supported
Yes
Bridged (load cells)
Maximum Normal Voltage Input
N/A
100 mV
Maximum Voltage Input
N/A
±35 V
IC694TBBx32, IC694TBSx32 or IC694TBC032. Sold Separately.
Terminal Block (20 screws), included with module.
300 mA @ 5V; 400 mA @ 3.3V
100 mA @ 5 VDC
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Range
Diagnostics
Channel-to-Channel Isolation
Number of Channels
Accuracy
Input Impedance
I/O Required
A/D Conversion Type
A/D Conversion Time
Connector Type
Internal Power Used
1.38
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
RTD I/O Modules
The RTD Input Modules provide RTD inputs that allow the direct connection of 2 and
3-wire RTD temperature sensors without using external signal processing (transducers,
transmitters, etc.). All analog and digital processing of the RTD signal is performed on
the module.
IC695ALG600 RTD
IC695ALG508 RTD
HE693RTD600
Isolated RTD Input module (also
supports Resistive) provides eight isolated
differential Resistive or RTD input channels.
Each channel can be individually configured
for 2, 3, 4 wire RTD or Resistance.
RTD Input Module,
Low Resolution
Product Name
Universal Analog and configurable for
Current, Voltage, RTD, Thermocouple and
Resistive. High Density (8 Channel) Requires
Cold Junction Compensation; are available
for Thermocouple configurations
(IC695ACC600 contains 2 CJCs)
Lifecycle Status
Active
Active
Active
RTD Input
RTD (and Resistive) Input
Channel to Channel Isolation
RTD Input
Universal Backplane Only. Uses PCI Bus.
Universal Backplane Only. Uses PCI Bus.
No Backplane Restrictions
Number of Slots Module
Occupies on Backplane
1
1
1
Number of Channels
8
8
6
2 and 3 wire PT 385 / 3916,
N 618 / 672, NiFe 518, CU 426
2, 3 and 4 wire 50, 100, 200, 500,
and 1000 ohm Pt 385; 50, 100, 200, 500, and
1000 ohm Pt 391.6; 100, 200, 500, and 1000
ohm Ni 618; 120 ohm Ni 672; 604 ohm NiFe
518; 10, 50 and 100 ohm Cu 426
3-wire, Pt-100E, Pt-100C, Pt-100Z,
Pt-1000, Cu-10, Cu-50, PT-100, Cu-53,
Cu-100, Ni-120, TD5R, TD5R,
Pt-90 (MIL-7990)
Open wire, short circuit, positive/negative
rate of change, High, High-High,
Low, Low-Low
Open wire, short circuit, positive/negative
rate of change, High, High-High,
Low, Low-Low
N/A
Two Groups of Four
250 VAC Continuous
1500 VAC 1 minute
2550 VDC 1 second
N/A
Notch Filter
Yes
N/A
N/A
Resolution
32-bit IEEE floating point or 16-bit integer
(in 32-bit field) input data format
32-bit IEEE floating point or 16-bit integer
(in 32-bit field) input data format
0.5ºC or 0.5ºF
Calibrated Accuracy at 25°C.
Typical is ±0.5%
±0.5ºC, typical
Accuracy
Calibrated Accuracy at 25°C.
Better than 0.1% of range. Accuracy
depends on A/D filter, data format,
input noise, and ambient temperature.
>1M ohm
N/A
>1000 Megohms
I/O Required
N/A
N/A
6 %AI
Fault Protection
N/A
N/A
Zener Diode Clamp
10ms per Channel; 4 Channels = 40ms (1KHz
filter)127ms per Channel * 4 Channels =
508ms (8Hz filter)Channels that are disabled
are not scanned, shortening scan time.
15 msec @ 28 Hz to 120 msec @ 2.3 Hz
50 Channels/second
Sigma Delta
Sigma Delta
18 bit, integrating
IC694TBBx32, IC694TBSx32 or IC694TBC032.
Sold Separately.
IC694TBBx32, IC694TBSx32 or IC694TBC032.
Sold Separately.
Terminal Block (20 screws),
included with module.
400 mA @ 5 V; 350 mA @ 3.3 V
150 mA @ 5V; 300 mA @ 3.3V
70 mA @ 5 VDC
Module Type
Backplane Support
RTD Types Supported
Diagnostics
Channel-to-Channel Isolation
Input Impedance
Update Time
A/D Conversion Type
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.39
PACSystems RX3i
Programmable Controllers
RTD I/O Modules
The RTD Input Modules provide RTD inputs that allow the direct connection of 2 and
3-wire RTD temperature sensors without using external signal processing (transducers,
transmitters, etc.). All analog and digital processing of the RTD signal is performed on
the module.
HE693RTD601
HE693RTD660
RTD Input Module,
High Resolution
RTD Input Module,
Isolated
Active
Active
RTD Input
RTD Input
No Backplane Restrictions
No Backplane Restrictions
Number of Slots Module
Occupies on Backplane
1
1
Number of Channels
6
6
3-wire, Pt-100E, Pt-100C, Pt-100Z,
Pt-1000, Cu-10, Cu-50, PT-100, Cu-53,
Cu-100, Ni-120, TD5R,
TD5R, Pt-90 (MIL-7990)
3 wire, Pt-100E, Pt-100C, Ni-120,
Cu-10, Pt-1000,TD5R Si
N/A
N/A
N/A
5 VAC
N/A
None
0.125ºC , 0.1ºC, or 0.1ºF
0.05ºC, 0.05ºF, 0.1ºC, 0.1ºF, 0.5ºC or 0.5ºF
±0.5ºC, typical
±0.3ºC
>1000 Megohms
>1000 Megohms
6 %AI
6% AI, 6% AQ, 16% I
Zener Diode Clamp
Suppression Diode
50 Channels/second
50 Channels/second
18 bit, integrating
18 bit, integrating
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
70 mA @ 5 VDC
200 mA @ 5 VDC
Product Name
Lifecycle Status
Module Type
Backplane Support
RTD Types Supported
Diagnostics
Channel-to-Channel Isolation
Notch Filter
Resolution
Accuracy
Input Impedance
I/O Required
Fault Protection
Update Time
A/D Conversion Type
Connector Type
Internal Power Used
1.40
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Strain Gage I/O Modules
The Millivolt Input Modules allow Millivolt level signals, such as bridged strain gages
(load cells) to be directly connected to the PLC without external signal processing
(transducers, transmitters, etc.) All analog and digital processing of the signal is
performed on the module.
IC695ALG600 Strain Gage
IC695ALG306 Strain Gage
IC695ALG312 Strain Gage
Universal Analog and configurable for Current,
Voltage, RTD, Thermocouple and Resistive.
High Density (8 Channel) Requires Cold
Junction Compensation; are available
for Thermocouple configurations
(IC695ACC600 contains 2 CJCs)
Isolated Thermocouple Input module
provides six isolated differential
thermocouple input channels. Each
channel can be individually configured
for inputs from: Thermocouple types:
J, K, T, E, R, S, B, N, or C and Voltage:
±150mV or ±50mV.
Isolated Thermocouple Input module
provides twelve isolated differential
thermocouple input channels. Each
channel can be individually configured
for inputs from: Thermocouple types:
J, K, T, E, R, S, B, N, or C and Voltage:
±150mV or ±50mV.
Active
Active
Active
Strain Gage Input
Strain Gage Input
Strain Gage Input
Universal Backplane Only. Uses PCI Bus.
Universal Backplane Only. Uses PCI Bus.
Universal Backplane Only. Uses PCI Bus.
1
1
1
±150mV or ±50mV
±150mV or ±50mV
±150mV or ±50mV
Open wire, short circuit, positive/negative
rate of change, High, High-High,
Low, Low-Low
Open wire, short circuit, positive/negative
rate of change, High, High-High,
Low, Low-Low
Open wire, short circuit, positive/negative
rate of change, High, High-High,
Low, Low-Low
Two Groups of Four
250 VAC Continuous
1500 VAC 1 minute
2550 VDC 1 second
250 VAC Continuous
1500 VAC 1 minute
2550 VDC 1 second
8
6
12
Resolution
32-bit IEEE floating point or 16-bit integer
(in 32-bit field) input data format
32-bit IEEE floating point or 16-bit integer
(in 32-bit field) input data format
32-bit IEEE floating point or 16-bit integer
(in 32-bit field) input data format
Accuracy
Calibrated Accuracy at 25°C. Better than 0.1%
of range. Accuracy depends on A/D filter, data
format, input noise, and ambient temperature.
±0.1% of voltage span at 25°C.
±0.25% of span over
temperature range.
±0.1% of voltage span at 25°C.
±0.25% of span over
temperature range.
>1M ohm
Voltage: >=500k ohm
Voltage: >=500k ohm
N/A
N/A
N/A
A/D Conversion Type
Sigma Delta
Sigma Delta
Sigma Delta
15 msec @ 28 Hz to
120 msec @ 2.3 Hz
15 msec @ 28 Hz to
120 msec @ 2.3 Hz
A/D Conversion Time
(Assumes 2 ADC’s running in parallel, no CJC or
lead resistance) 10ms per Channel 4 Channels = 40ms (1KHz filter) 127ms per Channel 4
Channels = 508ms (8Hz filter) Channels that are
disabled are not scanned, shortening scan time.
Strain Gages Supported
Yes
Yes
Yes
Maximum Normal
Voltage Input
N/A
N/A
N/A
±14.5 VDC continuous
N/A
N/A
IC694TBBx32, IC694TBSx32 or IC694TBC032.
Sold Separately.
IC694TBBx32, IC694TBSx32 or IC694TBC032.
Sold Separately.
IC694TBBx32, IC694TBSx32 or IC694TBC032.
Sold Separately.
400 mA @ 5 V; 350 mA @ 3.3 V
150 mA @ 5V; 400 mA @ 3.3V
300 mA @ 5V; 400 mA @ 3.3V
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Range
Diagnostics
Channel-to-Channel Isolation
Number of Channels
Input Impedance
I/O Required
Maximum Voltage Input
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.41
PACSystems RX3i
Programmable Controllers
Strain Gage I/O Modules
The Millivolt Input Modules allow Millivolt level signals, such as bridged strain gages
(load cells) to be directly connected to the PLC without external signal processing
(transducers, transmitters, etc.) All analog and digital processing of the signal is
performed on the module.
IC695ALG412
HE693STG883
HE693STG884
Analog I/O Module,
Strain Gage
Analog I/O Module,
Strain Gage
Product Name
Isolated Thermocouple Input module
provides twelve isolated differential
thermocouple input channels. Each channel
can be individually configured for inputs from:
Thermocouple types: J, K, T, E, R, S, B, N, or C
and Voltage: ±150mV or ±50mV. Offers a 10 dB
improvement in noise rejection compared to
ALG312 thermocouple inputs.
Lifecycle Status
Active
Active
Active
Strain Gage Input
Strain Gage Input
Strain Gage Input
Universal Backplane Only. Uses PCI Bus.
No Backplane Restrictions
No Backplane Restrictions
1
1
1
±50mV
N/A
N/A
Open wire, Short Circuit, Positive/Negative
rate of Change, High, High-High,
Low, Low-Low
N/A
N/A
Channel to Channel Isolation.
250VAC Continuous; 1500VAC 1 minute;
2550VDC 1 second
N/A
N/A
12
8
8
Resolution
32-bit IEEE floating point or 16 bit integer
(in 32 bit field) input data format
0.6 µV, 0.8 µV, 0.9 µV (respectively)
0.8 µV, 1.6 µV, 3.2 µV (respectively)
± 0.1% of voltage sp+GC+GB59GD1+GC59163an
at 25 °C.
± 0.25% of span over temperature range.
±0.3%
±0.3%
Accuracy
Voltage: >=500k ohm
>1000 Mohms
>1000 Mohms
N/A
8% AI, 16% I, 8% AQ, 16% Q
8% AI, 16% I, 8% AQ, 16% Q
Sigma Delta
Integrating
Integrating
15 msec @ 28 Hz to
120 msec @ 2.3 Hz
35 Channels/second
35 Channels/second
Yes
Bridged (load cells)
Bridged (load cells)
100 mV
100 mV
±35 V
±35 V
IC694TBBx32, IC694TBSx32 or IC694TBC032.
Sold Separately.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
425 mA @ 5V; 400 mA @ 3.3V
60 mA @ 5 VDC; 30 mA @ 24 VDC Relay
60 mA @ 5 VDC; 30 mA @ 24 VDC Relay
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Range
Diagnostics
Channel-to-Channel Isolation
Number of Channels
Input Impedance
I/O Required
A/D Conversion Type
A/D Conversion Time
Strain Gages Supported
Maximum Normal
Voltage Input
Maximum Voltage Input
Connector Type
Internal Power Used
1.42
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Temperature Control Modules
The Temperature Control Module (TCM), is a high performance control module providing
eight channels of thermocouple input and eight channels of control output in a single
RX3i module. Each channel can operate in closed or open loop mode relieving the PLC
of providing the temperature control functions. The module also supports Autotuning.
IC693TCM302
IC693TCM303
Product Name
PACSystems RX3i Temperature Control Module,
(8) T/C, (1) RTD and (8) 24 VDC Output
PACSystems RX3i Temperature Control Module,
Extended Range, (8) T/C, (1) RTD and (8) 24 VDC Output
Lifecycle Status
Mature
Mature
Temperature Control
Temperature Control
No Backplane Restrictions
No Backplane Restrictions
1
1
8 T/C In/ 8 DC Out
8 T/C In/ 8 DC Out
J=0-600°C
K=0-1050°C
L=0-600°C
J=0-450°C
K=0-600°C
L=0-450°C
Output Voltage Range
18 to 30 volts DC
18 to 30 volts DC
Load Current per Point
100 mA maximum sourcing
100 mA maximum sourcing
Open thermocouple and reverse connection
detection capability Detection and indication of
out-of-tolerance temperature readings
Open thermocouple and reverse connection
detection capability Detection and indication of
out-of-tolerance temperature readings
Two 20 pin connectors (screw type)
Two 20 pin connectors (screw type)
150 mA @ 5 VDC
150 mA @ 5 VDC
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Number of Channels
Range
Diagnostics
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.43
PACSystems RX3i
Programmable Controllers
Thermocouple I/O Modules
The Thermocouple Input Modules allow thermocouple temperature sensors to be directly
connected to the PLC with external signal processing (transducers, transmitters, etc.).
The module performs all analog and digital processing of the thermocouple signal. The
enhanced thermocouple input modules add isolation or high-resolution. On these modules,
each channel can be configured for a specific type of sensor wire. An autodetect external
AD592 cold junction compensation feature is also available.
IC695ALG600 Thermocouple
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Range
Diagnostics
IC695ALG306
Universal Analog and configurable
Isolated Thermocouple Input
for Current, Voltage, RTD,
module provides six isolated
Thermocouple and Resistive. High
differential thermocouple input
Density (8 Channel) Requires Cold
channels. Each channel can be
Junction Compensation; are available individually configured for inputs
for Thermocouple configurations
from: Thermocouple types: J, K, T, E,
(IC695ACC600 contains 2 CJCs)
R, S, B, N, or C and Voltage: ±150mV
or ±50mV.
IC695ALG312
IC695ALG412
Isolated Thermocouple Input
module provides twelve isolated
differential thermocouple input
channels. Each channel can be
individually configured for inputs
from: Thermocouple types: J, K, T, E,
R, S, B, N, or C and Voltage: ±150mV
or ±50mV.
Isolated Thermocouple Input
module provides twelve isolated
differential thermocouple input
channels. Each channel can be
individually configured for inputs
from: Thermocouple types: J, K, T, E,
R, S, B, N, or C and Voltage: ±50mV.
The ALG412 offers a 10dB
improvement in noise rejection
compared to the ALG312
thermocouple input module.
Active
Active
Active
ACtive
Thermocouple Input
Thermocouple Input
Thermocouple Input
Thermocouple Input
Universal Backplane Only.
Uses PCI Bus.
Universal Backplane Only.
Uses PCI Bus.
Universal Backplane Only.
Uses PCI Bus.
Universal Backplane Only.
Uses PCI Bus.
1
1
1
1
B, C, E, J, K, N, R, S, T
J, K, T, E, R, S, B, N, or C
J, K, T, E, R, S, B, N, or C
J, K, T, E, R, S, B, N, or C
Open wire, Short Circuit, Positive/
Negative Rate of Change, High, HighHigh, Low, Low-Low
Open wire, Short Circuit, Positive/
Negative Rate of Change, High,
High-High, Low, Low-Low
Open wire, Short Circuit, Positive/
Negative Rate of Change, High,
High-High, Low, Low-Low
Open wire, Short Circuit, Positive/
Negative Rate of Change, High,
High-High, Low, Low-Low
Number of Channels
8
6
12
12
Channel-to-Channel
Isolation
Two Groups of Four
250 VAC Continuous 1500 VAC 1
minute 2550 VDC 1 second
2.3 Hz filter, 50/60Hz: 100 dB 4 Hz
filter, 50Hz: 100 dB 4.7 Hz filter,
60Hz: 100 dB
70 dB minimum
250 VAC Continuous 1500 VAC 1
minute 2550 VDC 1 second
2.3 Hz filter, 50/60Hz: 100 dB 4 Hz
filter, 50Hz: 100 dB 4.7 Hz filter,
60Hz: 100 dB
70 dB minimum
250 VAC Continuous 1500 VAC 1
minute 2550 VDC 1 second
All filters, 50/60 Hz: 110 dB
From 2.3 Hz to 28 Hz per channel
From 2.3 Hz to 28 Hz per channel
Common Mode Rejection
120dB minimum @ 50/60 Hz with 8
Hz filter 110dB minimum @ 50/60 Hz
with 12 Hz filter
Chanel to Channel
Crosstalk
Notch Filter
Resolution
Accuracy
Update Rate
I/O Required
A/D Conversion Type
A/D Conversion Time
Connector Type
Internal Power Used
1.44
Yes
32-bit IEEE floating point or 16-bit
32-bit IEEE floating point or 16-bit
32-bit IEEE floating point or 16-bit
integer (in 32-bit field) input
integer (in 32-bit field) input
integer (in 32-bit field) input
data format
data format
data format
Calibrated Accuracy at 25°C.
±0.1% of voltage span at 25°C.
±0.1% of voltage span at 25°C
Better than 0.1% of range. Accuracy
±0.25% of span over
±0.25% of span over
depends on A/D filter, data format,
temperature range.
temperature range.
input noise, and ambient temperature.
10ms per Channel; 4 Channels =
10ms per Channel; 4 Channels =
10ms per Channel; 4 Channels =
40ms (1KHz filter)127ms per Channel * 40ms (1KHz filter)127ms per Channel 40ms (1KHz filter)127ms per Channel
4 Channels = 508ms (8Hz filter)
* 4 Channels = 508ms (8Hz filter)
* 4 Channels = 508ms (8Hz filter)
Channels that are disabled are not
Channels that are disabled are not
Channels that are disabled are not
scanned, shortening scan time.
scanned, shortening scan time.
scanned, shortening scan time.
N/A
N/A
N/A
70 dB minimum
From 2.3 Hz to 28 Hz per channel
32-bit IEEE floating point or 16-bit
integer (in 32-bit field) input
data format
±0.1% of voltage span at 25°C
±0.25% of span over
temperature range.
Configurable from 15 msec
to 120 msec.
N/A
Sigma Delta
Sigma Delta
Sigma Delta
Sigma Delta
(Assumes 2 ADC’s running in parallel,
no CJC or lead resistance) 10ms per
Channel 4 Channels = 40ms (1KHz filter)
127ms per Channel 4 Channels =
508ms (8Hz filter) Channels that
are disabled are not scanned,
shortening scan time.
IC694TB3x32, IC694TBSx32 or
IC694TBC032. Sold Separately.
400 mA @ 5 V; 350 mA @ 3.3 V
15 msec @ 28 Hz to
120 msec @ 2.3 Hz
15 msec @ 28 Hz to
120 msec @ 2.3 Hz
15 msec @ 28 Hz to
120 msec @ 2.3 Hz
IC694TB3x32, IC694TBSx32 or
IC694TBC032. Sold Separately.
225 mA @ 5V; 400 mA @ 3.3V
IC694TB3x32, IC694TBSx32 or
IC694TBC032. Sold Separately.
425mA @ 5V; 400 mA @ 3.3V
IC694TB3x32, IC694TBSx32 or
IC694TBC032. Sold Separately.
425mA @ 5V; 400 mA @ 3.3V
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Thermocouple I/O Modules
The Thermocouple Input Modules allow thermocouple temperature sensors to be directly
connected to the PLC with external signal processing (transducers, transmitters, etc.).
The module performs all analog and digital processing of the thermocouple signal. The
enhanced thermocouple input modules add isolation or high-resolution. On these modules,
each channel can be configured for a specific type of sensor wire. An autodetect external
AD592 cold junction compensation feature is also available.
HE693THM166
HE693THM409
HE693THM449
Analog I/O Thermocouple
Input Module
Analog I/O Thermocouple
Input Module
Analog I/O Thermocouple
Input Module
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Range
Active
Active
Active
Thermocouple Input
Thermocouple Input
Thermocouple Input
No Backplane Restrictions
No Backplane Restrictions
No Backplane Restrictions
1
1
1
J, K, N, T, E, R, S, B, C, X
J, K, N, T, E, R, S,
J, K, N, T, E, R, S,
Yes
No
Yes
Diagnostics
Number of Channels
16
4
4
Channel-to-Channel
Isolation
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0.5°C or 0.5°F
N/A
0.5°C or 0.5°F
N/A
0.5°C or 0.5°F
±0.5°C, typical (J, K, N, T)
±0.5°C, typical (J, K, N, T)
±0.5°C, typical (J, K, N, T)
N/A
N/A
N/A
16% AI, 16% I
4% AI
4% AI, 16% I
Integrating
Integrating
Integrating
40 Channels/second
40 Channels/second
40 Channels/second
Common Mode Rejection
Channel to Channel
Crosstalk
Notch Filter
Resolution
Accuracy
Update Rate
I/O Required
A/D Conversion Type
A/D Conversion Time
Connector Type
Internal Power Used
www.ge-ip.com
Terminal Block (20 screws), included with module.
80 mA @ 5 VDC; 30 mA @ 24 VDC Relay
Terminal Block (20 screws), included with module. Terminal Block (20 screws), included with module.
80 mA @ 5 VDC; 60 mA @ 24 VDC Relay
80 mA @ 5 VDC; 60 mA @ 24 VDC Relay
GE Intelligent Platforms Control Systems Solutions
1.45
PACSystems RX3i
Programmable Controllers
Thermocouple I/O Modules
The Thermocouple Input Modules allow thermocouple temperature sensors to be directly
connected to the PLC with external signal processing (transducers, transmitters, etc.).
The module performs all analog and digital processing of the thermocouple signal. The
enhanced thermocouple input modules add isolation or high-resolution. On these modules,
each channel can be configured for a specific type of sensor wire. An autodetect external
AD592 cold junction compensation feature is also available.
HE693THM809
HE693THM884
HE693THM888
HE693THM889
Analog I/O Thermocouple
Input Module
Analog I/O Thermocouple
Input Module (Enhanced)
Analog I/O Thermocouple
Input Module (Enhanced)
Analog I/O Thermocouple
Input Module
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Range
Active
Active
Active
Active
Thermocouple Input
Thermocouple Input
Thermocouple Input
Thermocouple Input
No Backplane Restrictions
No Backplane Restrictions
No Backplane Restrictions
No Backplane Restrictions
1
1
1
1
J, K, N, T, E, R, S
J, K, N, T, E, R, S, B, C
J, K, N, T, E, R, S, B, C
J, K, N, T, E, R, S
No
Yes
Yes
Yes
Diagnostics
Number of Channels
8
8
8
8
Channel-to-Channel
Isolation
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
0.5°C or 0.5°F
None
N/A
60 Hz
N/A
N/A
0.5°C or 0.5°F
±0.5°C, typical (J,K,N,T)
N/A
N/A
±0.5°C, typical (J,K,N,T)
N/A
N/A
N/A
N/A
8% AI, 16% I
Common Mode Rejection
Channel to Channel
Crosstalk
Notch Filter
Resolution
Accuracy
Update Rate
I/O Required
A/D Conversion Type
8% AI
8% AI, 8% AQ, 16% I
8% AI, 8% AQ, 16% I
Integrating
Integrating
Integrating
Integrating
40 Channels/second
N/A
N/A
40 Channels/second
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
80 mA @ 5 VDC;
60 mA @ 24 VDC Relay
100 mA @ 5 VDC;
60 mA @ 24 VDC Relay
100 mA @ 5 VDC;
60 mA @ 24 VDC Relay
80 mA @ 5 VDC;
60 mA @ 24 VDC Relay
A/D Conversion Time
Connector Type
Internal Power Used
1.46
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Resistive I/O Module
The Resistive module allows the user to easily connect to resistive loads without the need of
external devices.
IC695ALG600 Resistive
IC695ALG508 Resistive
Product Name
Universal Analog and configurable for Current, Voltage, RTD,
Thermocouple and Resistive. High Density (8 Channel) Requires
Cold Junction Compensation; are available for Thermocouple
configurations (IC695ACC600 contains 2 CJCs)
Isolated Resistive Input module (also supports RTD) provides
eight isolated differential Resistive or RTD input channels.
Each channel can be individually configured for 2, 3, 4
wire RTD or Resistance.
Lifecycle Status
Active
Active
Resistive Input
Resistive (and RTD) Input Channel to Channel Isolation
Universal Backplane Only. Uses PCI Bus.
Universal Backplane Only. Uses PCI Bus.
1
1
0 to 250 / 500 / 1000 / 2000 / 3000 / 4000 Ohms
250 / 500 / 1000 / 2000 / 3000 / 4000 Ohms
Open wire, short circuit, positive/negative rate of change, High,
High-High, Low, Low-Low
Open wire, short circuit, positive/negative rate of change, High,
High-High, Low, Low-Low
8
8
Two Groups of Four
250 VAC Continuous 1500 VAC 1 minute 2550 VDC 1 second
Notch Filter
Yes
N/A
Resolution
32-bit IEEE floating point or 16-bit integer
(in 32-bit field) input data format
32-bit IEEE floating point or 16-bit integer
(in 32-bit field) input data format
Calibrated Accuracy at 25ºC. Better than 0.1% of range.
Accuracy depends on A/D filter, data format, input noise, and
ambient temperature.
Calibrated Accuracy at 25ºC. Typical is ± 0.5%
Accuracy
>1M ohm
N/A
Input Filter Response
Configurable: 8Hz, 12Hz, 16Hz, 40Hz, 200Hz, 1000Hz
Configurable: 2.3Hz, 4Hz, 4.7Hz, 24Hz, 28Hz
A/D Conversion Type
Sigma Delta
Sigma Delta
15 msec @ 28 Hz to 120 msec @ 2.3 Hz
A/D Conversion Time
(Assumes 2 ADC’s running in parallel, no CJC or lead resistance)
10ms per Channel 4 Channels = 40ms (1KHz filter) 127ms per
Channel 4 Channels = 508ms (8Hz filter) Channels that are disabled are not scanned, shortening scan time.
±14.5 VDC continuous
N/A
IC694TBBx32, IC694TBSx32 or IC694TBC032. Sold Separately.
IC694TBBx32, IC694TBSx32 or IC694TBC032. Sold Separately.
"400 mA @ 5 V; 350 mA @ 3.3 V
150 mA @ 5V; 300 mA @ 3.3V
Module Type
Backplane Support
Number of Slots Module Occupies
on Backplane
Range
Diagnostics
Number of Channels
Channel-to-Channel Isolation
Input Impedance
Maximum Voltage Input
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.47
PACSystems RX3i
1
OK
2MODULE OK LAN
3
STAT
4
CONFIG
IC695HSC308
PNC001
TO INSTALL, TORQUE TO
6 IN LB. TO UNINSTALL,
REVERSE MOTION
ACTIVE
USB
USB
Programmable Controllers
Networks and Distributed I/O Systems
The RX3i features a variety of communications options for distributed control and/or I/O.
Choose from Profinet Controller, Ethernet EGD, Profibus-DP, Genius and DeviceNet. These
communication modules are easy to install and quick to configure.
RESET
IP ADDRESS
PORTS
FRONT
3 4
1 2
IC695ETM001
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Protocol Support
Entity Type
IC695PNC001
PACSystems RX3i Ethernet
PROFINET Controller (PNC) module,
TCP/IP 10/100Mbits, two RJ-45 ports connects a PACSystems RX3i conwith built-in switch
troller to a high-speed PROFINET
local area network. It enables the
RX3i controller to communicate
with IO-Devices on the LAN.
Active
Active
Active
Active
PROFINET Controller
Reflective Memory
Profibus Master
Universal Backplane Only.
Uses PCI Bus.
Universal Backplane Only.
Uses PCI Bus.
Universal Backplane Only.
Uses PCI Bus.
Universal Backplane Only.
Uses PCI Bus.
1
1
1
1
SRT, Ethernet Global Data (EGD),
Channels (Client and Server),
Modbus TCP (Client and Server)
Client/Server
PROFINET
None Required
Profibus DPV1
Master
Deterministic Peer to Peer.
Programmable Interrupt support.
Master
Two RJ-45 ports one MAC Address
Two RJ-45 and Two SFP Cages
(Not included, available separately).
Only one MAC address.
10/100/1000Mbaud
10/100Mbaud
Bus Speed
Maximum I/O Memory
IC695PBM300
PACSystems RX3i Profibus Master
Module, Supports DPV1 Class 1
and Class 2.
Ethernet
Communication Ports
I/O Device Update Rate
IC695CMX128
RX3i Control Memory Xchange
Module for Peer to Peer network.
128Megbytes of user
shared memory.
N/A
Configurable: 1 ms to 512 ms
N/A
128 Kbytes of combined input/output
memory per PROFINET Controller
Up to 4 PNC001 per CPU
IO- Devices per I/O Controller 64 IO-Devices per Network - 128
per network, across up to 8 I/O
controllers IO-Devices per CPU - 128
across 4 Profinet controllers Profinet
Slots per device - 256 Number of
Profinet Subslots per slot - 256 Number
of Profinet Submodules per CPU - 2048
100 meters for cooper
Up to 70,000 meters with Fiber
N/A
System Maximum Limits
Network Dependent
Network Distance
PROFIBUS DB-9 connector
Network link speed of 2.1 Gigabits/
sec. Network transfer rate of 43
Mbyte/s (4 byte packets) to 174
Mbyte/s (64 byte packets)
12Mbaud
Multimode Fiber up to 300 meters
between nodes. 10Km when
HUB is used
Baud Rate Dependent. Supports all
standard data rates (9.6 kBit/s, 19.2
kBit/s, 93.75 kBit/s, 187.5 kBit/s, 500
kBit/s, 1.5 MBit/s, 3 MBit/s, 6 MBit/s
and 12 MBit/s)
Yes, Slave Status Bit Array Table, Network Diagnostic Counters, DP Master
Diagnostic Counters, Firmware Module
Revision, Slave Diagnostic Address
Up To 125
(Requires repeater every 25 nodes)
Yes
Yes
Network error detection.
Network Dependent
64 Drops
256 Subslots
256
Bus Diagnostics
Number of Drops Supported
N/A
Message Size
244 bytes of input and 244 bytes of
output for each slave. Not to exceed
3584 bytes input and 3584 bytes
outputs total for the system.
Two RJ-45
Two RJ-45 and two optional SFP
plug connectors for copper or fiber
connections
Fiber optic LC type, conforms to IEC
61754-20; Zirconium ceramic ferrule;
Insertion loss 0.35 dB (maximum);
Return loss -30 dB
Profibus Connector
840 mA @ 3.3 VDC; 614 mA @ 5 VDC
3.3 V: 0.5 A with no SFP devices
installed 1.2 A maximum (two SFP
devices installed, 0.35 A per SFP
device) 5 V: 1.5 A maximum
660 mA @ +3.3 VD 253 mA @ +5 VDC
420 mA @ 5 VDC
Connector Type
Internal Power Used
1.48
Up to 128 Mbytes reflective memory
with parity. Dynamic packet sizes
of 4 to 64 bytes, automatically
controlled by the CMX module
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Networks and Distributed I/O Systems
The RX3i features a variety of communications options for distributed control and/or I/O.
Choose from Ethernet EGD, Profibus-DP, Genius and DeviceNet. These communication
modules are easy to install and quick to configure.
IC695PBS301
IC694BEM331
IC694DNM200
PACSystems RX3i Profibus Slave Module,
Supports DPV1 Class 1 and Class 2.
PACSystems RX3i
Genius Bus Controller
PACSystems RX3i
DeviceNet Master Module
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Active
Active
Active
Profibus Slave
Genius Bus Controller
DeviceNet Master
Universal Backplane Only.
Uses PCI Bus.
No Backplane Restrictions
CPU Rack Only
1
1
1
Profibus DPV1
Genius
DeviceNet
Protocol Support
Entity Type
Slave
Master
Master
PROFIBUS DB-9 connector
Screw Terminal
Screw Terminal
12Mbaud
153.6Kbaud
500Kbaud
Baud Rate Dependent. Supports all
standard data rates (9.6 kBit/s, 19.2 kBit/s, 93.75
kBit/s, 187.5 kBit/s, 500 kBit/s,
1.5 MBit/s, 3 MBit/s, 6 MBit/s and 12 MBit/s)
7500 feet (2286 meters) at 38.4 Kbaud; 4500 feet
(1371 meters) at 76.8 Kbaud; 3500 feet (1066
meters) at 153.6 Kbaud extended; 2000 feet (609
meters) at 153.6 Kbaud standard. Maximum length
at each baud rate also depends on cable type.
500Kbaud 100 meters to 125Kbaud
500 meters. Maximum length at each baud
rate also depends on cable type.
Yes, Alarms
Yes
Yes
N/A
32
64
244 bytes of input and 244 bytes of output
128 bytes
127 bytes
Profibus Connector
Screw Terminal
Screw Terminal
420 mA @ 5 VDC
300 mA @ 5 VDC
300 mA @ 5 VDC
Communication Ports
Bus Speed
I/O Device Update Rate
Maximum I/O Memory
System Maximum Limits
Network Distance
Bus Diagnostics
Number of Drops Supported
Message Size
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.49
PACSystems RX3i
Programmable Controllers
Co-Processor and Serial Communications Modules
RX3i features a wide range of Specialty Modules to meet all of your application needs.
From temperature controls, high-speed counters, I/O processors, coprocessors, to PID
auto-tuning modules, these Specialty Modules are designed to meet the demand for
versatile industrial solutions.
IC695CMM002
IC695CMM004
IC695PRS015
HE693ASC900
Two Port Serial Module
Four Port Serial Module
Pressure Transducer Module
supporting Honeywell LG1237
Smart Sensors
Horner ASCII Basic Module
Active
Active
Active
Active
Serial Communications
2 Isolated Serial Ports
Serial Communications
4 Isolated Serial Ports
Serial Communications
Serial Communications
4 Isolated Serial Ports
ASCII Basic Co-Processor
Universal Backplane Only.
Uses PCI Bus
Universal Backplane Only.
Uses PCI Bus
Universal Backplane Only.
Uses PCI Bus.
No Backplane Restrictions
1
1
1
1
Serial Read/Write Modbus
Master/Slave DNP 3.0 Master/
Slave CCM Slave and
Custom Protocols
Serial Read/Write Modbus
Master/Slave DNP 3.0 Master/
Slave CCM Slave and
Custom Protocols
Pressure Transducer Honeywell
LG1237 Smart Pressure
Transducer sensors
(Up to 15 sensors)
N/A
None required. Communications
set up in Proficy Machine Edition
None required. Communication
set up in Proficy Machine Edition
FLASH
FLASH
FLASH
EEPROM
(2) Isolated RS-232 or RS-485/422
(4) Isolated RS-232 or RS-485/422
(1) RS-485
RS-232, RS-232/485
Selectable Baud Rates: 1200,
2400, 4800, 9600, 19.2K, 38.4K,
57.6K, 115.2K
Selectable Baud Rates: 1200,
2400, 4800, 9600, 19.2K, 38.4K,
57.6K, 115.2K
375K baud
N/A
Network Data Rate
Internal Power Used
0.7 Amps maximum @ 3.3 VDC
0.115 Amps maximum @ 5 VDC
0.7 Amps maximum @ 3.3 VDC
0.150 Amps maximum @ 5 VDC
0.7 Amps maximum @ 3.3 VDC
0.115 Amps maximum @ 5.0 VDC
375 mA @ 5 VDC
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Protocols Supported
Programming Languages
Program Storage
Communication Ports
1.50
GE Intelligent Platforms Control Systems Solutions
BASIC
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Motion Control (High Speed Counting)
The High Speed Counters can be used for a wide range of applications. The following types are supported.
Type A - Up or Down-Independent Pulse-4 counters
Type B - Both Directions-A QUAD B Encoder Inputs-2 Counters
Type C - Difference Between 2 changing values-A QUAD B Encoder Inputs -1 Counter
Type D - provides homing capability with count inputs and a Home Marker input. In A quad B mode, the counter detects quadrature errors
Type E - Pre-defined Counter Type that occupies two of the module’s internal counters, primarily a down counter, but can handle up
counts to account for A quad B jitter
Type E counter counts down to zero, it uses a second counter block to turn on a dedicated output for a configurable time. Type E can be
set up for sequenced strobing, which links all four strobes on so that they are all triggered by strobe input 1
Type Z - Two regular Clock inputs, a software controlled Preload and a special Clock Input Z. The Z input triggers a store of the
Accumulator value to the Strobe 1 register. After the store, the counter can optionally reset the Accumulator to 0. It can then either restart
immediately or after wait until the Clock Input Z is no longer set User-Defined Counter Type - Create a customized counter type by selecting High-Speed Counter features that are suited to the application. This counter type provides a Clear input that can be used to immediately reset the Accumulator to the starting value.
IC694APU300
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Input/Output Type
Off State Leakage Current
Output Protection
Counter Operation
CPU Interrupt Support
PLS and Camming Support
Input Filters (Selectable)
Count Rate
Counter Range
Selectable On/Off
Output Presets
Counters per Timebase
Strobe Register
Local Fast Inputs
Local Fast Outputs
Connector Type
Internal Power Used
www.ge-ip.com
IC695HSC304
IC695HSC308
PACSystems RX3i
PACSystems RX3i
PACSystems RX3i
High Speed Counter
High Speed Counter
High Speed Counter
Active (Enhancement Mode
Active
Active
Available June 2012)
High Speed Counter (*Enhanced
High Speed I/O Processing
High Speed I/O Processing
Mode support: 1Mhz input frequency, (4 counters) Module supports High
(8 counters) Module supports High
expanded filtering, single ended,
Speed Counting, PLS (Programmable Speed Counting, PLS (Programmable
differential encoders, 32 bit counters,
Limit Switch), Camming, Input
Limit Switch), Camming, Input
Z counter and windowing)
Interrupts and Pulse Width Timing
Interrupts and Pulse Width Timing
No Backplane Restrictions
Universal Backplane Only.
Universal Backplane Only.
Uses PCI Bus.
Uses PCI Bus.
IC694APU305
PACSystems RX3i
I/O Processor Module
Active
I/O Processor Module
No Backplane Restrictions
1
1
1
1
Positive Logic
10 µA per point
3 Amp Fuse for all points, Enhanced
Module will have ESCP protection
Type A, Type B, and Type C
Enhanced Mode Type Z
Positive Logic
200 µA
1.5 A maximum per channel, 10.5 A
maximum per module
Type A, Type B, Type C, Type D, Type
E, Type Z and User-Defined Counter
Positive Logic
200 µA
1.5 A maximum per channel, 10.5 A
maximum per module
Type A, Type B, Type C, Type D, Type
E, Type Z and User-Defined Counter
N/A
10 µA per point
5 A Fuse for all points
No
Yes
Yes
No
Yes
Yes
High Frequency Filter - 2.5 μs;
30 Hz, 5 KHz, 50 KHz, 500 KHz, 5 MHz 30 Hz, 5 KHz, 50 KHz, 500 KHz, 5 MHz
Low Frequency Filter - 12.5 ms;
*Enhancement Mode: 5 ms, 500 μs,
10 μs and no filter
High Frequency - 80 kHz;
High Frequency 1.5 MHz
High Frequency 1.5 MHz
Low Frequency - 20 Hz;
(internal 2 MHz oscillator)
(internal 2 MHz oscillator)
*Enhanced Mode Up to 1MHz with
2MHz internal Oscillator
-2,147,483,648 to 2,147,483,648
-2,147,483,648 to 2,147,483,648
-65,535 to 65,535 ; *Enhanced Mode
-2,147,483,648 to 2,147,483,647 with
roll over detection
Each Counter has 2 present points,
Each Counter has 4 present points,
Each Counter has 4 present points,
On and Off; *Enhanced Mode up to 4
On and Off
On and Off
configurable outputs
Each counter stores the number
A Timebase from 100 nanoseconds A Timebase from 100 nanoseconds
of counts that have occurred in a
to 429,496 milliseconds can be
to 429,496 milliseconds can be
specified time. A timebase value
selected for each counter.
selected for each counter.
measurement from 1 ms to 65535
ms is configurable.
Each counter has one or more strobe Each counter has one or more strobe Each counter has one or more strobe
registers that capture the current
registers that capture the current
registers that capture the current
accumulator value when a strobe
accumulator value when a strobe
accumulator value when a strobe
input transition in the direction
input transition in the direction
input transition in the direction
selected during the last
selected during the last
selected during the last
configuration of the module.
configuration of the module.
configuration of the module.
(12) 5 VDC or 10 to 30 VDC
(8 inputs) 5 VDC nominal: 4.7 VDC
(16 inputs) 5 VDC nominal: 4.7 VDC
to 5.5 VDC 12 to 24 VDC nominal:
to 5.5 VDC 12 to 24 VDC nominal:
10 VDC to 26.4 VDC Inputs are
10 VDC to 26.4 VDC Inputs are
mapped to any counter or to the
mapped to any counter or to the
controller as interrupts.
controller as interrupts.
(4) 10 to 30 VDC @ 500 mA maximum
(7 outputs) 4.7 to 40 VDC 1.5 A
(14 outputs) 4.7 to 40 VDC 1.5 A
4.75 to 6 VDC @ 20 mA maximum
maximum per channel, 10.5 A
maximum per channel, 10.5 A
maximum per module Outputs can
maximum per module Outputs can
be used by the counters or as
be used by the counters or as
standard outputs from the controller. standard outputs from the controller.
Terminal Block (20 screws),
IC694TBBx32 or IC694TBSx32.
IC694TBBx32 or IC694TBSx32.
included with module.
Sold Separately.
Sold Separately.
250 mA @ 5 VDC
64 mA maximum @ 5 V;
94 mA maximum @ 5 V;
457 mA maximum @ 3.3 V
561 mA maximum @ 3.3 V
Gray Code Encoder or A Quad B
Encoder every 500 microseconds
N/A
N/A
N/A
30 kHz (Absolute Encoder) 200 kHz
(A Quad B Encoder)
N/A
N/A
N/A
N/A
(12) 8.0 VDC (non-VTTL),
1.5 VDC (TTL)
Continuous Output Current
(10°V30 VDC supply) 1.0 A
(each output 1-V4) 0.5 A
(each output 5-V8)
Terminal Block (20 screws),
included with module.
360 mA @ 5 VDC
GE Intelligent Platforms Control Systems Solutions
1.51
PACSystems RX3i
Programmable Controllers
PACMotion Servo Control
The PACMotion controller is a versatile servo motion controller that combines the benefits
of a highly integrated motion and machine logic solution with the performance, flexibility
and scalability required for advanced machine automation. PACMotion is designed to
deliver unsurpassed machine productivity required for today’s high-speed machines and
lean manufacturing environments. The 4-axis servo motion controller is built on a high
performance hardware platform, with a new enhanced motion engine, operating system,
and open standard integrated programming paradigm. Add to that world-class reliability
of FANUC servos and you have a motion system designed to give you the best productivity
and accuracy possible. Please see GE Intelligent Platforms Motion Solutions Catalog
GFA-483 for more information about motion offerings.
IC695PMM335
Product Name
PACMotion Module
Lifecycle Status
Active
Module Type
Backplane Support
Servo Motion
Universal Backplane Only. Uses PCI Bus.
Number of Slots Module Occupies on
Backplane
Motion Path Planning
1
1 ms, Consistent update regardless of the number of axes in the system
Position Loop Update Rate
500 µs, All axes in the RX3i rack are updated simultaneously
Velocity Loop Update Rate
125 µs, All axes in the RX3i rack are updated simultaneously
Torque Loop Update Rate
62.5 µs, All axes in the RX3i rack are updated simultaneously
Controlled Axes/Module
Master Axes/Module
Servo Command Interface
Fiber Terminal Block Cable Length
Maximum Axes per RX3i
Position Resolution
4 ßi, ßHVi or aHVi series servos are supported via a fiber optic interface
1, Can be a virtual time-based or incremental encoder master
Fiber Optic 50 Mb/s FANUC Serial Servo Bus (FSSB)
Max. 100 meters between nodes 400 meters maximum for a 4 axis system
DC Power Supplies: 40 + 10 master axes
(Requires 16 slot backplane, CPU and 4 DC power supplies)
AC Power Supplies: 32 + 8 master axes
(Requires 16 slot backplane, CPU and 3 AC power supplies)
aHVi Series 1,048,576 counts/rev, ßi and ßHVi Series 65,536 or 131,072 counts/rev.
ß2i and larger motors support the higher resolution.
Feedback Type
Incremental/Absolute Serial Encoder.
Optional battery backup required for absolute feedback mode.
Faceplate I/O
24V General Purpose Inputs: 4 optically isolated; source/sink
24V High-Speed Inputs: 2 optically isolated; source/sink Open circuit detection;
can be used to connect a quadrature master encoder (500 kHz max)
24V General Purpose Inputs/Outputs: 2 optically isolated; source/sink 125 mA
maximum output current each “Connecto” Plug-on Screw Terminal
Floating Point Support
Yes, Double precision IEEE 754.
Module Hot Insertion/Removal
Cam Profiles per Module
Synch/Delayed Start
High Speed Position Capture
Connector Type
Internal Power Used
1.52
Yes
256 at one time. Up to 2048 profiles can be stored
in the RX3i file system for use by any module.
Up to 8 axes Axes can be on any module and
are synchronized over the backplane.
±2 Inputs per axis: ±1 count = 10 µs jitter
Plug-on Screw Terminal and Fiber
5 VDC 0.45A @ 5 VDC; 1.1A & 3.3 VDC
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
PACMotion I/O Fiber Terminal Block
The optional Fiber Terminal Block enables PACMotion controller to connect remote I/O over
a fiber cable. The Fiber Terminal Block is DIN rail mounted and can be up to 100 meters
away from the PACMotion module. The module is configurable per point for 5 VDC, 24 VDC
and analog I/O. The Fiber Terminal Block provides a unique ID that prevents connection to
wrong PACMotion modules. The module supports up to 5 incremental encoders without
marker or 4 encoders with marker pulse.
IC695FTB001
Product Name
PACMotion I/O Fiber Terminal Block
Lifecycle Status
Active
Module Type
I/O Terminal Block for PACMotion
Mounting/Dimensions
35 mm DIN Rail
(5.56 W x 4.94 H x 2.46 D inches;
141.2 W x 125.5 H x 62.5 D mm)
Interface to PACMotion Module
Power Requirements
24 V Outputs (differential)
24 V General Purpose Inputs
5 V Outputs (differential)
Fiber Optic Cable.
Maximum cable length is 100 meters;
Interface uses a unique ID for each
PMM/FTB pair to prevent cross-connection.
19.2 VDC —28.8 VDC; 0.45 Amps @ 24 V
Eight optically isolated; source;
open load & short detection.
2 groups of 4; 0.5 A max. per point;
4 A max. per group
Sixteen optically isolated;
source/sink 4 groups of 4
Four RS422 Line Driver with
short circuit protection; 48 mA max.
5 V Inputs (differential/single-ended)
Six RS422 / RS485 Line Receiver
with fault detection
5 V Inputs (differential)
Six RS422 / RS485 Line Receiver
with fault detection
Analog Inputs
Two, ±10V differential 14 bit resolution
Analog Outputs
Two, ±10V differential 14 bit resolution
24 V Power Output
Reverse polarity protected
by replaceable fuse
5 V Power Output
0.5 amp max. electronic overload protected
Quad Encoder Open
Circuit Detection
Yes
I/O Function Assignment
Configurable I/O functions are assigned
during module hardware configuration
Terminal Header Options
IC694TBxx32
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.53
PACSystems RX3i
Programmable Controllers
Motion Control (Servo Control)
Motion control integrated into the RX3i fosters high performance point-to-point
applications. GE Motion Control modules can be flexibly applied to a variety of digital,
analog, and stepper motion applications.
IC694DSM324
IC694DSM314
Product Name
PACSystems RX3i Digital Servo Module, 4-Axis
(Fiber Optic Interface to Amplifiers)
PACSystems RX3i Digital Servo Module, 4-Axis
Lifecycle Status
Active
Active
Servo Motion
Servo Motion
No Backplane Restrictions
No Backplane Restrictions
1
1
Beta i Series Digital Servos
Alpha and Beta Series Digital and Analog Servos
Fiber Optic, Up to 100 meters between amplifiers
with total length of 400 meters.
Digital for Alpha and Beta Series; ±10 V velocity or
torque command for analog
4 Digital
2 Digital and 1 Analog or 4 Analog
Incremental Master (1Mhz)
Incremental Master (1Mhz)
Electronic Cam
Yes
Yes
Velocity Feed-Forward
Yes
Yes
Encoder Feedback (Serial)
Yes
Yes
Temposonic Feedback
Yes
Yes
Number of Programs
15 Kbytes (10 + 40 Subroutines)
15 Kbytes (10 + 40 Subroutines)
15 KBytes
15 KBytes
3
3
TTL Diff/Single, 175kHz
TTL Diff/Single, 175kHz
Analog Inputs
2
4 - In Digial Mode 8 - In Analog Mode
Analog Outputs
2
4 - In Digial Mode 0 - In Analog Mode
1360 mA @ 5 VDC
1300 mA @ 5 VDC
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Drive
Drive Interface
Axes
Master Encoder Support
User Memory (Number of Programs)
Feedback Inputs
Encoder Input Type/Maximum Rate
Internal Power Used
1.54
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Power Measurement Modules
The Power Transducer Module (PTM) and Power Synchronization and Measurement (PSM) module
measure and calculate critical data for control of electrical power systems and synchronization of
power grids. Both the PTM and PSM connect to user supplied current and potential transformers,
which translate power grid signals to proportionate, low-level signals for measurement and analysis.
The PTM module is not intended to provide a protective relay function or be used for energy billing
purposes. The PSM module provides ANSI protective relay calculations and revenue grade monitoring for a complete genset, paralleling switchgear or infrastructure management solution. Both the
PTM and PSM consist of a processing module that plugs into the PLC backplane, an interface module
for field wiring connections, and cables to interconnect the two modules. The PTM and PSM can be
used with Wye or Delta type three-phase power or with single-phase power systems.
Product Name
IC693PTM101
IC694PSM001
Power Transducer Module Processing Module interface
board (a panel mounted circuit board). This board interfaces between
the Power Transducer module and the input transformers (current
and potential), 1.0 meter Interface cable that connects the module
to the Interface board.
Power Synchronization and Measurement Module and Interface
Module (a panel mounted terminal block). The interface module
translates power grid signals from external, user supplied potential
and current transformers (PT’s and CT’s) to low voltage signals
suitable for the processing module. 2.0 meter Interface cables
connect the processing module to the Interface module.
Lifecycle Status
Module Type
Input Voltage Range
Power Measurement
Configurations
Current Input Range
Frequency Range
Output Rating
Number of Outputs
Data
Mature
Active
Power Transducer Modules
Power Synch and Measurement Module
GridsCircuits
10
0
up to 4
0 to 7.5 Amps RMS (5 A RMS nominal)
www.ge-ip.com
GridsCircuits
20
1
up to 3
0
up to 6
0 to 7.5 Amps RMS (5 A RMS nominal)
35Hz to 70Hz
40Hz to 70Hz
N/A
150 VAC/VDC, 1 A
0
1 (provided as redundant, isolated, solid-state contacts)
Data availability
• Data calculation rate: 20ms @ 50Hz, 16.67ms @ 60Hz
• Data latency: 15ms @ 50Hz, 16.67ms @ 60Hz
Data availability
• Data measurement rate: 20ms @ 50Hz, 16.67ms @ 60Hz.
• Data latency: 8ms
Measured Data
• RMS voltage of phase A, B, and C (in Volts x 10)
• RMS currents of phase A, B, C, and Neutral (in Amperes x 1000) for each grid
• DC component of measured RMS voltages (in Volts x 10)
• Frequency of phase A grid 1 (in Hz x 100)
• Phase angle between phase A grid 1 and phase A grid 2 (in degrees x 10)
Measured Data
• RMS voltage of phase A, B, and C (in Volts x 10)
• RMS currents of phase A, B, C, and Neutral (in Amperes x 1000) for each grid
• DC component of measured RMS voltages (in Volts x 10)
• Frequency of phase A grid 1 and phase A grid 2 (in Hz x 100)
• Phase angle between phase A grid 1 and phase A grid 2 (in degrees x 10)
Power and Energy Data
• Active and reactive power reported per phase and total in Watts, Volt-AmperesReactive (VAR)
• Active and reactive total energy consumption in Watt-Seconds and VoltAmperes-Reactive-Seconds (updated once per second), re-settable by the user
• Total power factor
• Average real and reactive power consumption (sliding 15 minute window
updated once per second)
Calculated Data
• Real and reactive power reported per phase and total in Watts, Volt-AmperesReactive (VAR)
• Real and reactive total energy consumption, integrated over the past 1-second,
in Kilo Watt-Hours (kWh) and Kilo Volt-Amperes-Reactive-Hours (kVARh)
• Total power factor
• Average real and reactive power consumption (sliding 15 minute window
updated once per second)
• Module Heartbeat (indicates module health)
• Utility Phase A voltage present
• Phase polarity valid
• Voltage measurements valid
• Current measurements valid
• Module Heartbeat (indicates module health)
• Field connection OK
• Any grid alarm (single bit indication of power grid health)
• Grid Voltage fault
• Grid Current fault
• Mixed Polarity fault
• ANSI Protection Relay Calculations
Grid Synchronization (ANSI 25)
Phase Shift OK
Voltage Difference OK
Frequency Difference OK
Close Relay OK
Under Voltage alarm (ANSI 27)
Reverse Power alarm (ANSI 32)
Negative Sequence alarm (ANSI 46)
Over Current alarm (ANSI 50)
Over Voltage alarm (ANSI 59)
VA Imbalance alarm (ANSI 60)
Under Frequency alarm (ANSI 81U)
Over Frequency alarm (ANSI 81O)
Status and Diagnostics
Internal Power Used
20-600 VAC (nominal)
10-120 VAC (nominal)
400 mA @ 5 VDC
190 mA @ 5 VDC
GE Intelligent Platforms Control Systems Solutions
1.55
PACSystems RX3i
Programmable Controllers
RX3i Pneumatic Module
This IC693MDL760 output module provides eleven pneumatic outputs and five 24 VDC sourcing outputs. For each pneumatic output, the module contains an internal 3-way solenoid-actuated valve
and an associated output fitting, which is located on the front panel. When an output is turned ON,
its internal valve connects a user supplied pressure source (100 psi maximum) to the output fitting.
The pressure source is connected to the fitting on the bottom of the module. When the output is
turned OFF, the valve’s output port is vented to atmosphere inside the module. Solenoid power is
supplied from an external 24 VDC source to the “DC Outputs” connector on the front panel.
IC693MDL760
Product Name
RX3i Solenoid Module
Lifecycle Status
Active
Number of Points
(11) Pneumatic Outputs
(5) 24 VDC Outputs
Pneumatic Outputs
Supply Pressure
Pressure Drop
11
100 PSI
25 psi [email protected] 0.25scfm
External Solenoid Power
21.6-26.4 VDC, 24 VDC nominal
ON Response Time/Off
Response Time
12ms max. ON 12ms max. OFF
Solenoid Inrush Current
33 mA/valve @ 24 VDC
Solenoid Holding Current
13 mA/valve @ 24 VDC
Output Fitting
Threaded for 10-32 adapter,
1/16” hose barb provided
Supply Fitting
Threaded for 10-32 adapter,
1/8” hose barb provided
Load Current per Point
Response Time (ms)
Output Type
Polarity
0.5 on/0.5 off
Transistor
Positive
Internal Power Used
1.56
0.5A @ 30 VDC per point,
2.0A total for all five points
75 mA from 5 VDC bus
(solenoid LEDs are powered
from external power source)
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Expansion Modules for Local and Remote I/O
The RX3i supports various expansion options for local and remote I/O to optimize
configurations. The RX3i can be expanded up to 8 expansion bases using local remote
expansion module. The RX3i also supports Ethernet remote I/O using the RX3i Ethernet
Network Interface module (IC695NKT001) Series 90-30 Ethernet Network Interface module
(IC693NIU004) for more distributed I/O.
IC695LRE001
IC695NKT001
IC693NIU004
PACSystems RX3i Expansion Module
PACSystems RX3i
Ethernet Remote I/O Expansion Kit.
Kit includes a NIU001 with two built-in
serial ports and ETM001
PACSystems RX3i
Ethernet Remote
I/O Expansion (Slave)
Active
Active
Active
High Speed Serial
Expansion Module
Ethernet Communications
(Supports redundant Ethernet modules)
Ethernet Communications
Universal Backplane Only
Universal Backplane Only.
Uses PCI Bus.
Compatible with Series 90-30 bases only
No I/O slot used
3 (2 for NIU and 1 for Ethernet module)
N/A
N/A
RJ-45 with built-in switch. 1 RS-485 port and
one RS-232 port. Supports SNP, Serial I/O,
Modbus Slave and Modbus Master
N/A
I/O Discrete Points
N/A
2048 Inputs/2048 Outputs maximum
2048 Inputs/2048 Outputs maximum
I/O Analog Points
N/A
1264 Inputs and 512 Outputs maximum
1264 Inputs and 512 Outputs maximum
User Logic Memory
N/A
5Kbytes of local logic
No local logic
Network Data Rate
1 Mbaud
10/100Mbit ports (RJ-45)
10/100Mbit ports (RJ-45)
Master
Slave
Slave
Up to 700 feet (213 meters)
Network Dependent
Network Dependent
Yes
Supported
Supported
Supports 7 local expansion racks.
Discrete I/O: Maximum 320 In, 320 Out,
Analog I/O: Maximum 160 In,
80 Out per base
Network Dependent
Each Ethernet NIU can also
support up to 7 additional
local I/O racks (IC694CHSxxx)
Network Dependent
Each Ethernet NIU can also
support up to 7 additional
local I/O racks (IC694CHSxxx)
132 mA @ 5 VDC
1250 mA @ 3.3 VDC; 1000 mA @ 5 VDC
for NIU controller and 840 mA @ 3.3 VDC;
614 mA @ 5 VDC for each Ethernet module
1.4 Amps @ 5 VDC
Product Name
Lifecycle Status
Module Type
Backplane Support
Number of Slots Module
Occupies on Backplane
Built-in Communication Ports
Entity Type
Network Distance
Bus Diagnostics
Number of Drops Supported
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.57
PACSystems RX3i
Programmable Controllers
Accessories
IC694TBB032
High Density 32 Point Terminal Block Box Style
Active
IC694TBB132
High Density 32 Point Terminal Block Box Style with Extended Shroud for Large Wiring Bundles
Active
IC694TBS032
High Density 32 Point Terminal Block Spring Style
Active
IC694TBS132
High Density 32 Point Terminal Block Spring Style with Extended Shroud for Large Wiring Bundles
Active
IC694TBC032
High Density 32 Point Terminal Block with a 40 pin Fujitsu connector. Compatible with DC Inputs, Analog Modules
only. Not compatible with DC or AC output modules.
Target April 2012
IC694ACC310
Filler Module, Blank Slot
Active
IC694ACC311
Terminal blocks, 20 terminals (qty 6) for IC694xxx low density modules
Active
IC695ACC600
RX3i Cold Junction Compensation Kit (Contains 2 CJCs) for Universal Analog and Thermocouple Input Modules
Active
IC698ACC701
Lithium Batter pack that installs in CPU for CPU310 and CMU310 only (28 days of continuous battery backup)
Active
IC693ACC302
External High capacity battery pack. (1.3 years of continuous battery backup for CPU310/CMU310 and 1 month
for CPU320/CRU320.)
Active
IC690RBK001
Rechargeable battery kit. Includes battery (IC690RBT001) and battery charger (IC690CRG001). The rechargeable
battery is compatible with PAC controllers CPU310,CPU315, CPU320 and CRU320 only. Also compatible with Series
90-30 and Series 90-70 CPUs.
Active
IC690CRG001
Battery charger. Compatible with rechargeable battery (IC690RBT001) only. The rechargeable battery is compatible with
PAC controllers CPU310,CPU315, CPU320 and CRU320 only. Also compatible with Series 90-30 and Series 90-70 CPUs.
Active
IC690RBT001
Rechargeable battery is compatible with IC690CRG001 battery charger only. The rechargeable battery is compatible
with PAC controllers CPU310, CPU315, CPU320 and CRU320 only. Also compatible with Series 90-30 and Series 90-70
CPUs., Series 90-30 and Series 90-70.
Active
IC690ACC001
Real Time Clock Battery for CPE305 and CPE310
Active
IC695ACC400
CPE305 and CPE310 CPU Battery-less Energy Pack for backing up dynamic data
Active
IC695CBL001
Energy Pack Cable
Active
IC690ACC901
Mini-Converter Kit with cable (RS-485/RS-232)
Active
IC690ACC903
RS-485 Port Isolator
Active
IC693CBL316
RS-232 cable for RX3i CPE305 programming port and also the Station Manager Cable for the Ethernet ETM001
Active
IC690CDR002
User Manuals, InfoLink CD-ROM Documentation, single-user license
Active
IC693ACC307
I/O Bus Terminator Plug
Active
IC693ACC311
Series 90-30 style IC693 I/O modules Terminal Blocks, 20 terminals (qty 6)
Active
External Power Supplies
IC690PWR024
24 VDC, 5 Amp Output Power and 120/230 VAC Input Power Power Supply
Active
IC690PWR124
24 VDC, 10 Amp Output Power and 120/230 VAC Input Power Power Supply
Active
Terminal Block Quick Connect
Terminal Block Quick Connect (TBQC) for selected I/O modules enables the user to easily connect interposing terminal blocks. The TBQC consists
of an I/O faceplate adapter that includes a 24 pin Fujitsu male connector (the faceplate replaces the 20 screw terminal connector on front of I/O
module, not compatible with the high density 36 screw terminals), cable and interposing terminal block.
TBQC I/O Module Face Plate Adapter
IC693ACC334
1.58
I/O module face plate adapter for 20 screw type I/O modules. Faceplate provides a 24 pin male
Fujitsu connector.
GE Intelligent Platforms Control Systems Solutions
Active
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
TBQC Interposing Terminal Block
IC693ACC329
Interposing terminal block base for IC694MDL645, IC694MDL646, and IC694MDL240. The base can also be
used with any 20 point terminal discrete or analog modules not listed.
Active
IC693ACC330
Interposing terminal block base for IC694MDL740 and IC694MDL742
Discontinued
IC693ACC331
Interposing terminal block base for IC694MDL741
Discontinued
IC693ACC332
Interposing terminal block base for IC694MDL940
Active
IC693ACC333
Interposing terminal block base for IC694MDL340
Active
IC693ACC337
Interposing terminal block base for IC693MDL654/655/752/753 and IC694MDL654/655/752/753
Active
IC693CBL327
Cable, Left Side, One -24 Pin 90 Degree Connector, 3 Meter. Cable has a connector on only one end and open
on the other. Cable used with TBQC I/O Face Plate Adapter or Fujitsu style I/O modules.
Active
IC693CBL328
Cable, Right Side, One -24 Pin 90 Degree Connector, 3 Meter. Cable has a connector on only one end and open
on the other. Cable used with TBQC I/O Face Plate Adapter or Fujitsu style I/O modules.
Active
IC693CBL329
Cable, Left Side, One -24 Pin 90 Degree Connector, 1 Meter. from TBQC I/O Face Plate Adapter to TBQC
Interposing Terminal Block.
Active
IC693CBL330
Cable, Right Side, One -24 Pin 90 Degree Connector, 1 Meter. from TBQC I/O Face Plate Adapter to TBQC
Interposing Terminal Block.
Active
IC693CBL331
Cable, Left Side, One -24 Pin 90 Degree Connector, 2 Meter. from TBQC I/O Face Plate Adapter to TBQC
Interposing Terminal Block.
Active
IC693CBL332
Cable, Right Side, One -24 Pin 90 Degree Connector, 2 Meter. from TBQC I/O Face Plate Adapter to TBQC
Interposing Terminal Block.
Active
IC693CBL333
Cable, Left Side, One -24 Pin 90 Degree Connector, 0.5 Meter. from TBQC I/O Face Plate Adapter to TBQC
Interposing Terminal Block.
Active
IC693CBL334
Cable, Right Side, One -24 Pin 90 Degree Connector, 0.5 Meter. from TBQC I/O Face Plate Adapter to TBQC
Interposing Terminal Block.
Active
TBQC Cables
High Density Terminal Block Quick Connect (32 point I/O terminals)
High Density Terminal Block Quick Connect (TBQC) for selected I/O modules enables the user to easily connect
interpossing terminal blocks. The HDTBQC consist of a I/O module terminal block with a 40 pin Fujitsu male
connector, cable and interposing terminal block. The HDTBQC is compatible with modules that accept
IC694TBC032 (24 VDC discrete inputs and analog input and output modules. The HDTBQC is not compatible
with discrete output modules).
HDTBQC I/O Module Face Plate Adapter
IC694TBC032
High Density 32 Point Terminal Block with a 40 pin Fujitsu connector. Compatible with DC Inputs,
Analog Modules only. Not compatible with DC or AC output modules.
Active
HDTBQC Interposing Terminal Block
IC694RTB032
Remote Terminal Block 36 Pin DIN-Rail mount
Target April 2012
HDTBQC Remote Terminal Base
IC694CBL005
.5 meter Cable between IC694TBC032 and IC694RTB032
Target April 2012
IC694CBL010
1.0 meter Cable between IC694TBC032 and IC694RTB032
Target April 2012
IC694CBL030
3.0 meter Cable between IC694TBC032 and IC694RTB032
Target April 2013
IC694CBL130
3 meter Cable with IC694TBC032 connector on one end and open wire on other end
Target April 2014
HDTBQC Cables
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.59
PACSystems RX3i
Programmable Controllers
RMX and CMX Reflective Memory Fiber Optic Cables
Simplex LC to LC connector, Fiber-Optic Cable – Multimode 62.5 Micron core.
Simplex (single) cabling is used for daisy chaining Tx to Rx to/from another node until final device circles back to beginning node.
Each CMX module requires two Simplex cables per module.
CBL-000-F5-000
.5 feet (0.15 m)
Active
CBL-000-F5-001
1 foot (.31 m)
Active
CBL-000-F5-002
5 feet (1.52 m)
Active
CBL-000-F5-003
10 feet (3.04 m)
Active
CBL-000-F5-004
25 feet (7.62 m)
Active
CBL-000-F5-005
50 feet (15.24 m)
Active
CBL-000-F5-006
80 feet (24.40 m)
Active
CBL-000-F5-007
100 feet (30.49 m)
Active
CBL-000-F5-008
150 feet (45.72 m)
Active
CBL-000-F5-009
200 feet (60.98 m)
Active
CBL-000-F5-010
250 feet (76.20 m)
Active
CBL-000-F5-011
350 feet (106.68 m)
Active
CBL-000-F5-012
500 feet (152.15 m)
Active
CBL-000-F5-014
656 feet (200 m)
Active
CBL-000-F5-015
820 feet (250 m)
Active
CBL-000-F5-016
1,000 feet (304.30 m)
Active
Duplex LC to LC connector, Fiber-Optic Cable - Multimode 62.5 Micron core.
Duplex cabling is generally used with RMX system and is also good for CMX module to HUB connections. Duplex has a pair of cables connected together.
Each CMX module requires one Duplex cable per module to a hub.
CBL-000-F6-000
3 feet (0.9144 m)
Active
CBL-000-F6-001
6 feet (1.8288 m)
Active
CBL-000-F6-002
10 feet (3.048 m)
Active
CBL-000-F6-003
16 feet (4.8768 m)
Active
CBL-000-F6-004
32 feet (9.7536 m)
Active
CBL-000-F6-005
66 feet (20.1168 m)
Active
CBL-000-F6-006
98 feet (29.8704 m)
Active
CBL-000-F6-007
164 feet (49.9872 m)
Active
CBL-000-F6-008
230 feet (70.104 m)
Active
CBL-000-F6-009
328 feet (99.9744 m)
Active
CBL-000-F6-010
393 feet (119.7864 m)
Active
CBL-000-F6-011
426 feet (129.8448 m)
Active
CBL-000-F6-012
492 feet (149.9616 m)
Active
CBL-000-F6-013
557 feet (169.7736 m)
Active
CBL-000-F6-014
656 feet (199.9488 m)
Active
CBL-000-F6-015
721 feet (219.7608 m)
Active
CBL-000-F6-016
754 feet (229.8192 m)
Active
CBL-000-F6-017
820 feet (249.936 m)
Active
CBL-000-F6-018
885 feet (269.748 m)
Active
CBL-000-F6-019
984 feet (299.9232 m)
Active
1.60
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Reflective Memory Interface Modules for PCs
PMC 5565 Reflective Memory PMC Module
PMC-5565PIORC-110000
PMC, 2 GIGA Baud RM w/FO Options, 128 Mbyte Memory, 4K FIFOs, Multimode Transmission
Active
PMC-5565PIORC-111000
PMC, 2 GIGA Baud RM w/FO Options, 128 Mbyte Memory, 4 K FIFOs, Single Mode Transmission
Active
PMC-5565PIORC-210000
PMC, 2 GIGA Baud RM w/FO Options, 256 Mbyte Memory, 4K FIFOs, Multimode Transmission
Active
PMC-5565PIORC-211000
PMC, 2 GIGA Baud RM w/FO Options, 256 Mbyte Memory, 4 K FIFOs, Single Mode Transmission
Active
PCI 5565 Reflective Memory PCI Module
PCI-5565PIORC-110000
PCI, 2 GIGA Baud RM w/FO Options, 128 Mbyte Memory, 4K FIFOs, Multimode Transmission
Active
PCI-5565PIORC-111000
PCI, 2 GIGA Baud RM w/FO Options, 128 Mbyte Memory, 4K FIFOs, Single Mode Transmission
Active
PCI-5565PIORC-210000
PCI, 2 GIGA Baud RM w/FO Options, 256 Mbyte Memory, 4K FIFOs, Multimode Transmission
Active
PCI-5565PIORC-211000
PCI, 2 GIGA Baud RM w/FO Options, 256 Mbyte Memory, 4K FIFOs, Single Mode Transmission
Active
PCI Express 5565 Reflective Memory PCIE Module
PCIE-5565RC-100000
PCI Express, 2 GIGA Baud RM w/FO Options, 128 Mbyte Memory, 4K FIFOs, Multimode Transmission
Active
PCIE-5565RC-101000
PCI Express, 2 GIGA Baud RM w/FO Options, 128 Mbyte Memory, 4K FIFOs, Single Mode Transmission
Active
PCIE-5565RC-200000
PCI Express, 2 GIGA Baud RM w/FO Options, 256 Mbyte Memory, 4K FIFOs, Multimode Transmission
Active
PCIE-5565RC-201000
PCI Express, 2 GIGA Baud RM w/FO Options, 256 Mbyte Memory, 4K FIFOs, Single Mode Transmission
Active
CMX and RMX Reflective Memory HUB (Contact GE for additional HUB configurations)
HUB-5595-308
DIN-Rail Mount Reflective Memory Hub. 21 -32 VDC Power supply, 1x 10BaseT Ethernet, 1x RS232,
8x Multimode Pluggable transceivers
Active
HUB-5595-380
DIN-Rail Mount Reflective Memory Hub. 21 -32 VDC Power supply, 1x 10BaseT Ethernet, 1x RS232,
8x Single mode Pluggable transceivers
Active
ACC-5595-208
Rack Mount or Desktop Reflective Memory Hub. Universal power supply, 1x 10BaseT Ethernet, 1x RS232,
8x multimode pluggable transceivers
Active
ACC-5595-280
Rack Mount or Desktop, 8 Single mode Pluggable Transceivers. And no Multimode Pluggable Transceivers
Active
Starter Kits (Only one starter kit per customer per customer site)
IC695STK001
RX3i Controller PACkage 1 Starter Kit includes RX3i with software. (includes one each IC695CPU305, IC695CHS012,
IC695LRE001, IC695PSA040, IC695ETM001, IC694ACC300, IC694MDL940 and IC646MPP001.) Limited one RX3i
starter kit per customer site.
IC695STK002
RX3i with Control and View. Power PACkage 2 Starter Kit includes RX3i and QuickPanel View 6” STD with
Active
software. (includes one each IC695CPU305, IC695CHS012, IC695LRE001, IC695PSA040, IC695ETM001, IC694ACC300,
IC694MDL940, IC754VSI06STD, BC646MQP001, IC646MPP001 and DC power supply for QuickPanel) Limited one
RX3i starter kit per customer site.
IC695STK003
RX3i, The Complete PACkage with Control, Motion and View. Power PACkage 3 Starter Kit includes RX3i, motion
Active
module (Servo and Amplifier sold separately) and QuickPanel View 6” STD with software. (includes one each
IC695CPU305, IC695CHS012, IC695LRE001, IC695PSA040, IC695ETM001, IC694DSM314, IC694ACC300, IC694MDL940,
IC754VSI06STD, BC646MQP001, IC646MPP001 and DC power supply for QuickPanel) Limited one RX3i starter kit per
customer site.
IC695STK004
RX3i Power PACkage 4 Starter Kit includes (one each IC695CPU305, IC695CHS012, IC695PSA040, IC695ETM001,
IC646MPP101)
Active
IC695STK005
RX3i Power PACkage 5 Starter Kit includes (one each IC695CPU305, IC695CHS012, IC695PSA040, IC646MPP101)
Active
IC695STK006
RX3i Power PACkage 6 Starter Kit includes (one each IC695CPU305, IC695CHS012, IC695PSD040, IC695ETM001,
IC646MPP101)
Active
IC695STK007
RX3i Power PACkage 7 Starter Kit includes (one each IC695CPU305, IC695CHS012, IC695PSD040, IC646MPP101)
Active
IC695STK010
RX3i Profinet Power PACkage 10. Kit includes CPE305, 7 slot base, AC power supply, input and output module,
Profinet controller, VersaMax Profinet slave, combination I/O and Proficy Machine Edition. (one each IC695CPU305,
IC695CHS007, IC695PSA040,IC694ACC300, IC694MDL740, IC200PNS001, IC200PWR102, IC200MDD844,
IC200ACC302, IC200CHS002, IC646MPP101)
Active
www.ge-ip.com
Active
GE Intelligent Platforms Control Systems Solutions
1.61
PACSystems RX3i
Programmable Controllers
Demo Cases
IC695DEM001
RX3i Power PACkage 1 Demo Case that includes CPU, P/S, discrete I/O and analog I/O, high speed counter, Ethernet
and analog simulator. Proficy Machine Edition Professional Edition included.
Active
IC695DEM002
RX3i Power PACkage 2 Demo Case that includes RX3i and QP Control/View. Includes CPU, P/S, discrete I/O and analog
I/O, Ethernet, analog simulator, 6” TFT QuickPanel View/Control. Proficy Machine Edition Professional Edition included.
Active
IC695DEM004
Beta i Series 1-Axis Motion Demo Case. Demo case is a self contained table top demo that includes a DSM324i module, Active
Beta i motor and amplifier prewired for connection to a DSM324i motion module. The cables (1 meter) for connection
to the DSM324i 5 V I/O and FSSB fiber optic command interface are included. Demo includes an E-stop push button
and toggle switches for 5 DSM324i I/O points.
IC694 Rack to Rack Expansion Cables
IC693CBL300
Cable, I/O Base Expansion, 1 Meter, Shielded
Active
IC693CBL301
Cable, I/O Base Expansion, 2 Meters, Shielded
Active
IC693CBL302
Cable, I/O Base Expansion, 15 Meter, Shielded with built-in terminator
Active
IC693CBL312
Cable, I/O Base Expansion, 0.15 Meter, Shielded
Active
IC693CBL313
Cable, I/OBase Expansion, 8 Meters, Shielded
Active
IC693CBL314
Cable, I/O Base Expansion, 15 Meters, Shielded with no built-in terminator
Active
IC693ACC307
I/O Bus Terminator Plug
Active
1.62
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Configuration Guidelines
When configuring a RX3i the following guidelines should be considered:
1.
IC695 part numbers can only be installed in a Universal Rack (IC695CHSxxx).
2.
CPU, NIU and AC Power Supply require 2 slots each on the base plate.
3.
IC695 I/O modules and high density IC694 I/O modules require a terminal block assembly. IC694TBSxxx (spring clamp termination) or
IC694TBBxxx (box style termination) are required.
4.
If the CPU is powered down frequently a high capacity battery should be considered. (IC693ACC302)
Examples of Typical Application
Configuration for Controller
(Example application requiring (120) 24 VDC inputs and (80) Relay outputs AC power supply)
Backplane Slots Required
Power Supply Current Required (mA)
2
[email protected] 3.3VDC; [email protected] 5VDC
Qty
Part Number
Description
1
IC695CPE310
CPU with two built-in serial ports
1
IC695PSA040
120/240 VAC, 125 VDC Power Supply, current available
9 Amps @ 3.3 VDC; 6 Amps @ 5 VDC; 1.6 Amps @ 24 VDC
maximum
600 [email protected] 3.3 VDC; 240 [email protected] 5 VDC
1
IC695CHS016
16 Slot Universal Base
4
1200 @ 5 V
4
IC694MDL660
Discrete Input Module, 24 VDC Positive Logic, 32 points
(Requires terminal block)
5
35 mA @ 5 V; 110 mA @ 24 VDC Relay
5
IC694MDL940
Discrete Output Module, Relay 2.0 A per point Form A,
16 points (Terminal block included).
4
IC694TBB032
Terminal Block, Box Style
1
IC646MPP001
Logic Developer -PLC Professional
1
IC695ETM001
Ethernet module 10/100Mbits
1
IC690PWR024
24 VDC, 5 Amp Output Power and 120/230 VAC Input
Power Power Supply
1
IC754VSI06STD
QuickPanel View Intermediate 6 inch STN Touch
Operator Interface
2
13
Total current from power supply
required: 2475 mA @ 5 V; 1600 @
3.3 V; 110 mA @ 24 VDC Relay.
Only one power supplied needed.
Options to consider
840 mA @ 3.3 VDC; 614 mA @ 5 VDC
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.63
PACSystems RX3i
Programmable Controllers
Configuration for Controller
(100) 24 VDC inputs, (50) 24 VDC Outputs with ESCP protection, (20) Relay outputs also (2) 4 to 20 mA Analog Inputs, (3) Type J Thermocouple,
(1) RTD, (5) Strain Gage, (12) 4 to 20 mA Analog Outputs and 24 VDC power supply. Also requires Profibus Master and Ethernet communications.
Backplane Slots Required
Power Supply Current Required (mA)
Qty
Part Number
Description
2 on Universal Base
1000 [email protected] 3.3 VDC; 1000 [email protected] 5 VDC
1
IC695CPE310
CPU with two built-in serial ports
1
IC695PSD040
24 VDC Power Supply, current available 9 Amps @ 3.3 VDC;
6 Amps @ 5 VDC; 1.6 Amps @ 24 VDC maximum
1 on Universal Base
600 [email protected] 3.3 VDC; 240 [email protected] 5 VDC
1
IC695CHS016
16 Slot Universal Base
4 expansion base slots
1200 @ 5 VDC
4
IC694MDL660
Discrete Input Module, 24 VDC Positive Logic, 32 points
(Requires terminal block)
2 expansion base slots
600 mA @ 5 VDC
2
IC694MDL754
Discrete Output Module, 24 VDC Output with ESCP, 32
points (Requires terminal block)
2 expansion base slots
35 mA @ 5 VDC; 110 mA @ 24 VDC Relay 2
IC694MDL940
Discrete Output Module, Relay 2.0 A per point Form A, 16
points (Terminal block included).
2 on Universal Base
700 mA @ 3.3 VDC; 800 mA @ 5 VDC
2
IC695ALG600
Universal Analog Input module, supports Thermocouple,
RTD, Voltage, Current and Strain Gage, 8 channels (Requires
terminal block)
2 on Universal Base
220mA @ 5VDC 630mA @ 24VDC
user supply
2
IC694ALG392
Analog Output module, supports voltage and current,
8 channels
1 on Universal Base
840 mA @ 3.3 VDC; 614 mA @ 5 VDC
1
IC695ETM001
Ethernet module 10/100Mbits
1 on Universal Base
420 mA @ 5 VDC
1
IC695PBM300
Profibus Master module, supports V1
150 mA @ 5 VDC
1
IC694CHS392
High Speed Serial 10 slot expansion rack (Only IC694xxx
modules can go in rack)
1
IC694PWR331
24 VDC Power Supply for High Speed Serial base,
1
IC693CBL312
Rack Expansion Cable, 0.15 meters
1
IC693ACC307
I/O Bus Terminator Plug
1
IC695LRE001
Universal Base High Speed Serial expansion module
(Module does not occupy a I/O slot)
8
IC694TBB032
Terminal Block, Box Style
1
IC646MPP001
Logic Developer -PLC Professional
132 mA @ 5 VDC
9 slots on Universal base and 8
slots of standard base
In the above configuration, all of the modules can not go into one base. Therefor the I/O modules are divided into two bases.
The IC695xxx part numbers will be used on the Universal base and the IC694 part numbers will use the standard high speed serial
bus base. The Universal base can accept both IC695xxx and IC694xxx modules but the standard base will only accept IC694xxx and
IC693xxx modules. Total current from Universal base power supply: 3140mA @ 5VDC ; 3140 @ 3.3VDC. Only one power supplied needed.
Total current from Standard base power supply: 1985mA @ 5VDC; 110mA @ 24VDC
Options to consider
1.64
GE Intelligent Platforms Control Systems Solutions
2
IC695PSD140
Multipurpose 24 VDC power supply.
By adding two IC665PSD140 the system would have
redundant power supplies for maximum availability.
1
IC690PWR024
24 VDC, 5 Amp Output Power and 120/230 VAC Input
Power Power Supply
1
IC754VSI06STD
QuickPanel View Intermediate 6 inch STN Touch
Operator Interface
www.ge-ip.com
Programmable Controllers
Redundant Controller Configuration
PACSystems RX3i
requiring (100) 24 VDC inputs, (50) 24 VDC Outputs with ESCP protection, (20) Relay outputs also (2) 4 to 20 mA Analog Inputs, (3) Type J
Thermocouple, (1) RTD, (5) Strain Gage, (12) 4 to 20 mA Analog Outputs and 24 VDC power supply. Also requires Profibus Master in I/O rack to
talk to (3) Variable Frequency Drives. Ethernet communications is also required to connect to HMIs.
Redundant Controllers Configuration
Backplane Slots Required
Power Supply Current Required (mA)
2 slots per Universal Base
1250 mA @ 3.3 VDC; 1000 mA @ 5 VDC
Part Number
Description
2
IC695CMU310
Redundant Controller, CPU with two built-in serial ports
2
IC695PSD040
24 VDC Power Supply, current available 9 Amps @ 3.3 VDC; 6
Amps @ 5 VDC; 1.6 Amps @ 24 VDC maximum
600 mA @ 3.3 VDC; 240 mA @ 5 VDC
2
IC695CHS012
12 Slot Universal Base
840 mA @ 3.3 VDC; 614 mA @ 5 VDC
4
IC695ETM001
Ethernet module 10/100Mbits
1
IC646MXN001
Redundant Controller configuration software. Max-ON Extended
Software for PACSystems Rx3i Hot Standby Redundancy
1 slot per Universal Base
2 slots per Universal Base
Qty
Note: The above configuration has two separate racks. Each rack has its own power supply, redundant CPU, Ethernet communications to remote I/O and another Ethernet
module for LAN connections to HMIs. GE highly recommends that the Ethernet I/O be separated from the enterprise network to minimize data traffic issues.
I/O for Redundant Controllers
3 on Universal Base (2 for the NIU
and 1 for the Ethernet Module)
1250 mA @ 3.3 VDC; 1000 mA @ 5 VDC
1
IC695NKT001
Ethernet Remote I/O Expansion Kit. Kit includes a IC695NIU001
and a IC695ETM001
1
IC695PSD040
24 VDC Power Supply, current available 9 Amps @ 3.3 VDC; 6
Amps @ 5 VDC; 1.6 Amps @ 24 VDC maximum
600 mA @ 3.3 VDC; 240 mA @ 5 VDC
1
IC695CHS016
16 Slot Universal Base
4 expansion base slots
1200 @ 5 VDC
4
IC694MDL660
Discrete Input Module, 24 VDC Positive Logic, 32 points (Requires
terminal block)
2 expansion base slots
600 mA @ 5 VDC
2
IC694MDL754
Discrete Output Module, 24 VDC Output with ESCP,
32 points (Requires terminal block)
2 expansion base slots
35 mA @ 5 VDC; 110 mA @ 24 VDC Relay
2
IC694MDL940
Discrete Output Module, Relay 2.0 A per point Form A,
16 points (Terminal block included).
2 on Universal Base
700 mA @ 3.3 VDC; 800 mA @ 5 VDC
2
IC695ALG600
Universal Analog Input module, supports Thermocouple, RTD, Voltage, Current and Strain Gage, 8 channels (Requires terminal block)
2 on Universal Base
750 mA @ 3.3 VDC
2
IC695ALG708
Analog Output module, supports voltage and current,
8 channels (Requires terminal block)
420 mA @ 5 VDC
1
IC695PBM300
Profibus Master module, supports V1
150 mA @ 5 VDC
1
IC694CHS392
High Speed Serial 10 slot expansion rack (Only IC694xxx modules
can go in rack)
1
IC694PWR331
24 VDC Power Supply for High Speed Serial base,
1
IC693CBL312
Rack Expansion Cable, 0.15 meters
1
IC693ACC307
I/O Bus Terminator Plug
1
IC695LRE001
Universal Base High Speed Serial expansion module
(Module does not occupy an I/O slot)
10
IC694TBB032
Terminal Block, Box Style
1
IC646MPP001
Logic Developer -PLC Professional
1 on Universal Base
1 on Universal Base
132 mA @ 5 VDC
9 slots on Universal base and 8 slots
of standard base
In the above configuration, all of the modules can not go into one base. Therefore the I/O modules are divided into two bases. The
IC695xxx part numbers will be used on the Universal base and the IC694 part numbers will use the standard high speed serial bus base.
The Universal base can accept both IC695xxx and IC694xxx modules but the standard base will only accept IC694xxx and IC693xxx
modules. Total current from Universal base power supply: 2460 mA @ 5 VDC; 3300 @ 3.3 VDC. Only one power supplied needed.
Total current from Standard base power supply: 1985 mA @ 5 VDC; 110 mA @ 24 VDC
Options to Consider
www.ge-ip.com
IC695PSD140
Multipurpose 24 VDC power supply. By adding two IC665PSD140
the system would have redundant power supplies for maximum
availability on the Un.
IC690PWR024
24 VDC, 5 Amp Output Power and 120/230 VAC Input Power
Power Supply
IC693ACC302
Long term battery for CPU
IC754VSI06STD
QuickPanel View Intermediate 6 inch STN Touch Operator Interface
GE Intelligent Platforms Control Systems Solutions
1.65
PACSystems RX3i
Programmable Controllers
α and βi Series Servo Amplifiers
All Digital Servo Systems Offer High Performance and Reliability. FANUC HVis
and βi Series Servo Drives, based on over five million axes installed worldwide,
offer superior reliability and performance for unprecedented mean time
between failure. The HVis and βi Series Servos are available in a wide range
of ratings for use with the PACMotion motion controller.
High-Performance
Serial Encoders
Standard serial encoders built into the
motors provide exceptional feedback
­resolution of 64K or 128K counts per
revolution for is Series motors and
one million counts per revolution for
HVis Series motors. Serial encoders
support higher resolutions at high
motor velocities than standard
quadrature encoders and are more
immune to noise. An optional battery
connection provides absolute position
feedback, eliminating the need
to home the system after a power
shutdown.
Reduced Tuning and Setup
There is no need for potentiometer
tuning or personality modules; little
tuning is required for properly sized
drives. All drive parameters are stored
in the controller in a standard motor
database. Configuration settings are
not stored in the drive, making it possible to replace drives with little set-up
time. Stored drive and machine
parameters are quickly transferred to
repeat production machines.
All-Digital System
All control loops—current, velocity,
and position—are closed in the
GE PACMotion controller. High-speed
microprocessors and/or digital signal
processors (DSPs) in the controller
provide loop update times of 250 µs.
The high response servo system can
compensate for machine design
limitations, yielding faster
acceleration/deceleration rates
and better responses to load changes.
1.66
Series
Motor Series
Controllers
Command
Interface
In-lb
Nm
αHVi
αHVi, αHVis
PMM335
Fiber Optic
195-664
22-75
Separate PSM
βi
βis
PMM335
Fiber Optic
3.5-177
0.4-20
Built-in
βHVi
βHVis
PMM335
Fiber Optic
17.7-177
2-20
Built-in
All-Digital Servo
Command Signals
The PMM335 PACMotion Controller and
βi or αi Series amplifiers use a high
speed fiber optic command interface.
This digital interface improves efficiency by varying the on-time of the
transistor switches that control motor
­voltage and current. With its superior
noise immunity, both of these FANUC
digital command interfaces allows for
an increased signal to noise ratio for
improved accuracy and performance.
GE Intelligent Platforms Control Systems Solutions
Continuous
Torque Range
Power Supply
Agency Approvals
UL, IEC rating and CE mark compliant
INFO
For application, installation, and tuning
information, consult the Services website at
www.ge-ip.com.
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
VersaMotion
VersaMotion is a family of servo
motors and amplifiers that can easily
be connected to the RX3i DSM 314.
The VersaMotion amplifier supports
high speed pulse and direction commands from the controllers. The
VersaMotion servo drive is simple to
use and maintain with the added diagnostics and removable terminal strips.
Amplifier setup can be accomplished
using the VersaMotion software
included with Proficy Machine Edition
or using the convenient front panel
­keypad.
Key Features:
• Versatile analog or pulse command
interface
• Position/Speed/Torque modes
• Dual control modes
Built-in Functions:
• Internal single-axis position control
• Point-to-Point single axis position
control
• Electronic gearing
• External JOG function
• Speed/Torque limit operation
• Built-in keypad/display for setup and
diagnostics
• Motor settling time below 1 ms
• Low speed stability and
performance: less than 0.5% error
at 1 RPM
• 10msec acceleration time from running without load -/+ 3000 RPM
• High speed inertia corrections
(16 levels of system stiffness and
­responsiveness)
www.ge-ip.com
• Simple stand-alone positioning
­function with 8 internal stored
­position settings
Machine Edition VersaMotion
Set-up Features:
• Configuration Parameter Editor
(clear, read, write functions) and
i­nitial configuration wizard
• Calculation tools to determine ­
proper conversion from encoder
counts to desired user programming
units
• Move to Home function
• Position Teaching capability
• Incremental encoder feedback
(2500 ppr)
• User-definable
Acceleration/Deceleration with jerk
limiting (s-curve)
• Feed step control function
• Modbus Slave serial port (RS-485/
RS-422) for reading and writing
parameters from Machine Edition
• Three channel digital oscilloscope to
display and record drive status
on-line
• Alarm history and status monitor
diagnostic screens
• Digital I/O set-up and monitoring
GE Intelligent Platforms Control Systems Solutions
1.67
PACSystems RX3i
Programmable Controllers
Servo Amplifier Part Number Sequence
IC800VMA
04
2
Input Voltage
2– 220 VAC Single Phase
Rated Power
01– 100 Watts
02– 200 Watts
04– 400 Watts
07– 750 Watts
10– 1000 Watts
20– 2000 Watts
30–­3000 Watts
Example: IC800VMA042 is a 400 watt 220 VAC servo amplifier
Amplifiers Technical Data
Permissible Frequency Fluctuation
50 / 60 Hz ±5%
Resolution/Quadrature Feedback Counts
2500 ppr /10000 cpr
Control Modes
Position/Velocity/Torque
Dynamic Brake
Built-in
Position Control Mode:
Maximum Input Pulse Frequency
500KPPS (Line Driver) / Maximum 200KPPS (Open Collector)
Pulse Type
Pulse/Direction;
Command Source
External pulse train/ Internal parameters
Torque Limit Operation
Yes
Feed Forward Compensation
Yes
CW/CCW;
A/B Phase
Analog Commands: Voltage Range
0 to ±10 VDC
Torque and Velocity Control Mode: Command Source
External analog signal / Internal parameters
Speed Control Range
1:5000
Speed Control Frequency Response
Maximum 450 Hz
Torque Control Mode Permissible Time for Overload
8 seconds under 200% rated output
Communications Interface
RS-232 / RS-485 /RS-422
Environmental Altitude
Altitude 1000 meters above sea level or lower
Environmental Operating Temperature
0 to 55°C (Forced cooling for operation above 55°C)
Environmental Storage Temperature
-20°C to 65°C
Environmental Humidity
0 to 90% (Non condensing)
Vibration
<20 Hz: 9.8 m/sec/sec (1G); 20 to 50 Hz: 5.88 m/sec/sec (0.6 G)
Standards
IEC/EN 61800-5-1, UL 508C, TUV, C-tick
1.68
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Amplifiers
The VersaMotion family of servo amplifiers offers a cost effective solution for a broad range
of motion applications. These versatile amplifiers support simple stand-alone positioning
capability using up to 8 stored motion profiles or can be connected to any motion controller
using an analog or pulse command interface. A built-in touchpad and display provides
convenient access to configuration parameters and system information. The serial interface
supports multi-drop system configurations and Modbus communication protocol.
IC800VMA012
IC800VMA022
IC800VMA042
IC800VMA072
Product Name
VersaMotion Amplifier
VersaMotion Amplifier
VersaMotion Amplifier
VersaMotion Amplifier
Lifecycle Status
Active
Active
Active
Active
Rated Output Power
100W
200W
400W
750W
Voltage/Frequency
Three-phase or
Single-phase 220 VAC
50/60 Hz
Three-phase or
Single-phase 220 VAC
50/60 Hz
Three-phase or
Single-phase 220 VAC
50/60 Hz
Three-phase or
Single-phase 220 VAC
50/60 Hz
Permissible Voltage
Fluctuation
Three-phase: 170 ~ 255 VAC
Single-phase: 200 ~ 255 VAC
Three-phase: 170 ~ 255 VAC
Single-phase: 200 ~ 255 VAC
Three-phase: 170 ~ 255 VAC
Single-phase: 200 ~ 255 VAC
Three-phase: 170 ~ 255 VAC
Single-phase: 200 ~ 255 VAC
Convection
Convection
Convection
Fan Cooling
Gear Ratio = N/M where N:
1~32767, M: 1:32767
(1/50<N/M<200)
Gear Ratio = N/M where N:
1~32767, M: 1:32767
(1/50<N/M<200)
Gear Ratio = N/M where N:
1~32767, M: 1:32767
(1/50<N/M<200)
Gear Ratio = N/M where N
Cooling System
Electronic Gear Ratio
1~32767, M: 1:32767
(1/50<N/M<200)
IC800VMA102
IC800VMA202
IC800VMA302
Product Name
VersaMotion Amplifier
VersaMotion Amplifier
VersaMotion Amplifier
Lifecycle Status
Active
Active
Active
Rated Output Power
1KW
2KW
3KW
Voltage/Frequency
Three-phase or
Single-phase 220 VAC
50/60 Hz
Three-phase 220 VAC
50/60 Hz
Three-phase 220 VAC
50/60 Hz
Permissible Voltage
Fluctuation
Three-phase: 170 ~ 255 VAC
Single-phase: 200 ~ 255 VAC
Three-phase: 170 ~ 255 VAC
50/60 Hz
Three-phase: 170 ~ 255 VAC
50/60 Hz
Fan Cooling
Fan Cooling
Fan Cooling
Gear Ratio = N/M where N:
1~32767, M: 1:32767
(1/50<N/M<200)
Gear Ratio = N/M where N:
1~32767, M: 1:32767
(1/50<N/M<200)
Electronic gear N/M
multiple N: 1~32767, M:
1:32767 (1/50<N/M<200)
Cooling System
Electronic Gear Ratio
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.69
PACSystems RX3i
Programmable Controllers
Servo Motor Part Number Sequence
IC800VMM
30
M
B
K
S
E25
Feedback
E25– 2500 ppr incremental encoder
Rated Power
01– 100 Watts
02– 200 Watts
04– 400 Watts
07– 750 Watts
10– 1000 Watts
20– 2000 Watts
30–­3000 Watts
Shaft Seal
S– With seal
Key
K– With shaft key
Brake
N– No brake
B– With brake (except 100 Watt Motor)
Inertia
L– Low Inertia
M– Medium Inertia (1Kw, 2Kw and 3Kw models only)
Example: IC800VMM30MBKSE25 is a 3000 watt medium Inertia motor with 2500 ppr encoder, brake, keyway and shaft seal.
Motors Technical Data
Insulation Class
Class B
Insulation Resistance
>100M ohm, 500 VDC
Insulation Strength
1500 VAC, 50Hz, 60 seconds
Vibration Grade (um)
15
Brake Power (VDC)
24
Operating Temperature (C)
0°~40°
Storage Temperature (C)
-10°~80°
Humidity
20~90%RH (non condensing)
Vibration
2.5G
IP Rating
IP65 (except shaft and connector)
1.70
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Motors
The VersaMotion family of servo motors offers high servo performance in a compact
­package. The motors range from 100 W to 3 kW with continuous torque ratings from 0.3
Nm to 14.3 Nm. All motors have metric mounting configurations and include a shaft key
and oil seal. For vertical axes or applications that need to hold position during power
loss motors with 24 VDC holding brakes are available. Motors are matched with the
VersaMotion amplifiers.
IC800VMM01L
IC800VMM02L
IC800VMM04L
IC800VMM07L
Product Name
VersaMotion
100 Watt
VersaMotion
200 Watt
VersaMotion
400 Watt
VersaMotion
750 Watt
Lifecycle Status
Active
Active
Active
Active
Rated Output (kW)
0.1
0.2
0.4
0.75
Rated Torque (Nm)
0.32
0.64
1.27
2.39
Maximum Torque (Nm)
0.96
1.92
3.82
7.16
Rated Speed (RPM)
3000
3000
3000
3000
Maximum Speed (RPM)
5000
5000
5000
5000
Rated Current (Amps)
0.9
1.55
2.6
5.1
Maximum Current (Amps)
2.7
4.65
7.8
15.3
Rotor Moment of Inertia (Kg.m2 x 10-4)
0.037
0.177
0.277
1.13
Mechanical Time Constant (msec)
0.75
0.8
0.53
0.63
Torque Constant - KT (Nm)
0.36
0.41
0.49
0.47
Voltage Constant - KE (mV/rmp)
13.6
16
17.4
17.2
Armature Resistance (Ohm)
9.3
2.79
1.55
0.42
Armature Inductance (mH)
24
10.84
6.84
3.53
Electrical Time Constant (msec)
2.58
3.89
4.43
8.37
Maximum Radial Shaft Load (Newton)
78.4
196
196
245
Maximum Thrust Shaft Load (Newton)
39.2
68
68
98
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.71
PACSystems RX3i
Programmable Controllers
Motors
The VersaMotion family of servo motors offers high servo performance in a compact
­package. The motors range from 100 W to 3 kW with continuous torque ratings from 0.3
Nm to 14.3 Nm. All motors have metric mounting configurations and include a shaft key
and oil seal. For vertical axes or applications that need to hold position during power loss
motors with 24 VDC holding brakes are available. Motors are matched with the VersaMotion
amplifiers.
IC800VMM10L
IC800VMM10M
IC800VMM20L
IC800VMM20M
IC800VMM30M
Product Name
VersaMotion
1000 Watt
VersaMotion
1000 Watt
VersaMotion
2000 Watt
VersaMotion
2000 Watt
VersaMotion
3000
Lifecycle Status
Active
Active
Active
Active
Active
WattRated Output (kW)
1.0
1.0
2.0
2.0
3.0
Rated Torque (Nm)
3.18
4.77
6.37
9.55
14.32
Maximum Torque (Nm)
9.54
14.32
19.11
28.66
42.96
Rated Speed (RPM)
3000
2000
3000
2000
2000
Maximum Speed (RPM)
5000
3000
5000
3000
3000
Rated Current (Amps)
7.3
5.6
11.3
11.0
16.1
Maximum Current (Amps)
21.9
24.9
33.9
33.0
48.3
Rotor Moment of Inertia (Kg.m2 x 10-4)
2.65
9.14
4.45
15.88
55
Mechanical Time Constant (msec)
0.74
1.64
0.66
1.05
1.06
Torque Constant - KT (Nm/A)
0.44
0.85
0.53
0.87
0.89
Voltage Constant - KE (mV/rpm)
16.8
31.9
19.2
31.8
32
Armature Resistance (Ohm)
0.20
0.465
0.14
0.174
0.052
Armature Inductance (mH)
2.0
5.99
1.53
2.76
1.38
10.26
12.88
10.63
15.86
26.39
Maximum Radial Shaft Load (Newton)
490
490
490
490
1470
Maximum Thrust Shaft Load (Newton)
98
98
98
98
490
IC800VMA102
IC800VMA102
IC800VMA202
IC800VMA202­
IC800VMA302
Electrical Time Constant (msec)
Amplifier Model
1.72
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
VersaMotion Accessories
Amplifier Connectors
IC800VMACONCN1
CN1 I/O Connector
Active
IC800VMACONCN2
CN2 Encoder Connector
Active
IC800VMACONCN3
CN3 Communication Connector
Active
IC800VMACONACP
AC Power Connector (100W to 1kW models only)
Active
IC800VMACONMTRP
Motor Power Connector (100W to 1kW models only)
Active
IC800VMADBR001
External Braking Resistor Connector (100W to 1kW models only)
Active
IC800VMMCONP001
Motor Power Connector for 100 Watt to 750 Watt motors without brake
Active
IC800VMMCONP002
Motor Power Connector for 100 Watt to 750 Watt motors with brake
Active
IC800VMMCONP003
Motor Power Connector for 1000 Watt or 2000 Watt motors with or without brake
Active
IC800VMMCONP004
Motor Power Connector for 3000 Watt motors with or without brake
Active
IC800VMMCONE001
Encoder Connector for 100 Watt to 750 Watt motors
Active
IC800VMMCONE002
Encoder Connector for 1000 Watt and larger motors
Active
Motor Connectors
Motor Power Cables
IC800VMCP030
Power Cable for 100 Watt to 750 Watt servo motor without brake, 3 m (9.8 feet)
Active
IC800VMCP050
Power Cable for 100 Watt to 750 Watt servo motor without brake, 5 m (16.4 feet)
Active
IC800VMCP100
Power Cable for 100 Watt to 750 Watt servo motor without brake, 10 m (32.8 feet)
Active
IC800VMCP200
Power Cable for 100 Watt to 750 Watt servo motor without brake, 20 m (65.7 feet)
Active
IC800VMCP1030
Power Cable for 1000 Watt servo motor without brake, 3 m (9.8 feet)
Active
IC800VMCP1050
Power Cable for 1000 Watt servo motor without brake, 5 m (16.4 feet)
Active
IC800VMCP1100
Power Cable for 1000 Watt servo motor without brake, 10 m (32.8 feet)
Active
IC800VMCP1200
Power Cable for 1000 Watt servo motor without brake, 20 m (65.7 feet)
Active
IC800VMCP2030
Power Cable for 2000 Watt servo motor without brake, 3 m (9.8 feet)
Active
IC800VMCP2050
Power Cable for 2000 Watt servo motor without brake, 5 m (16.4 feet)
Active
IC800VMCP2100
Power Cable for 2000 Watt servo motor without brake, 10 m (32.8 feet)
Active
IC800VMCP2200
Power Cable for 2000 Watt servo motor without brake, 20 m (65.7 feet)
Active
IC800VMCP3030
Power Cable for 3000 Watt servo motor without brake, 3 m (9.8 feet)
Active
IC800VMCP3050
Power Cable for 3000 Watt servo motor without brake, 5 m (16.4 feet)
Active
IC800VMCP3100
Power Cable for 3000 Watt servo motor without brake, 10 m (32.8 feet)
Active
IC800VMCP3200
Power Cable for 3000 Watt servo motor without brake, 20 m (65.7 feet)
Active
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.73
PACSystems RX3i
Programmable Controllers
Brake and Motor Power Cables
IC800VMCB030
Brake and Motor Power Cable for 200 Watt to 750 Watt servo motor with brake, 3 m (9.8 feet)
Active
IC800VMCB050
Brake and Motor Power Cable for 200 Watt to 750 Watt servo motor with brake, 5 m (16.4 feet)
Active
IC800VMCB100
Brake and Motor Power Cable for 200 Watt to 750 Watt servo motor with brake, 10 m (32.8 feet)
Active
IC800VMCB200
Brake and Motor Power Cable for 200 Watt to 750 Watt servo motor with brake, 20 m (65.7 feet)
Active
IC800VMCB1030
Brake and Motor Power Cable for 1000 Watt servo motor with brake, 3 m (9.8 feet)
Active
IC800VMCB1050
Brake and Motor Power Cable for 1000 Watt servo motor with brake, 5 m (16.4 feet)
Active
IC800VMCB1100
Brake and Motor Power Cable for 1000 Watt servo motor with brake, 10 m (32.8 feet)
Active
IC800VMCB1200
Brake and Motor Power Cable for 1000 Watt servo motor with brake, 20 m (65.7 feet)
Active
IC800VMCB2030
Brake and Motor Power Cable for 2000 Watt servo motor with brake, 3 m (9.8 feet)
Active
IC800VMCB2050
Brake and Motor Power Cable for 2000 Watt servo motor with brake, 5 m (16.4 feet)
Active
IC800VMCB2100
Brake and Motor Power Cable for 2000 Watt servo motor with brake, 10 m (32.8 feet)
Active
IC800VMCB2200
Brake and Motor Power Cable for 2000 Watt servo motor with brake, 20 m (65.7 feet)
Active
IC800VMCB3030
Brake and Motor Power Cable for 3000 Watt servo motor with brake, 3 m (9.8 feet)
Active
IC800VMCB3050
Brake and Motor Power Cable for 3000 Watt servo motor with brake, 5 m (16.4 feet)
Active
IC800VMCB3100
Brake and Motor Power Cable for 3000 Watt servo motor with brake, 10 m (32.8 feet)
Active
IC800VMCB3200
Brake and Motor Power Cable for 3000 Watt servo motor with brake, 20 m (65.7 feet)
Active
IC800VMCE030
Encoder Cable for 100 to 750 Watt, 3 m (9.8 feet)
Active
IC800VMCE050
Encoder Cable for 100 to 750 Watt, 5 m (16.4 feet)
Active
IC800VMCE100
Encoder Cable for 100 to 750 Watt, 10 m (32.8 feet)
Active
IC800VMCE200
Encoder Cable for 100 to 750 Watt, 20 m (65.7 feet)
Active
IC800VMCE1030
Encoder Cable for 1000 Watt and greater, 3 m (9.8 feet)
Active
IC800VMCE1050
Encoder Cable for 1000 watt and greater, 5 m (16.4 feet)
Active
IC800VMCE1100
Encoder Cable for 1000 watt and greater, 10 m (32.8 feet)
Active
IC800VMCE1200
Encoder Cable for 1000 watt and greater, 20 m (65.7 feet)
Active
I/O Terminal Block Breakout Board and 0.5 m (1.6 feet) Cable
Active
Encoder Cables
I/O Terminal Block
IC800VMTBC005
External Braking Resistors
IC800VMBR040
40 Ohm, 400 Watt External Braking (Regeneration) Resistor
Active
IC800VMBR020
20 Ohm, 1000 Watt External Braking (Regeneration) Resistor
Active
Communications and I/O Interface Cables
IC800VMCS030
Communications Cable from servo amplifier to PC, 3 m (9.8 feet)
Active
IC800VMCI010
Flying lead I/O interface cable, 1 meter
Active
IC800VMCI030
Flying lead I/O interface cable, 3 meter
Active
Software Configuration Tool
IC646MPM101
Proficy Logic Developer - PLC Nano/Micro and VersaMotion, Programming Cable (No Upgrades included)
Active
BC646MPM101
Proficy Logic Developer - PLC Nano/Micro and VersaMotion, Programming Cable (Includes 15 months of upgrades)
Discontinued
1.74
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
PACSystems RX3i
Examples of Typical Application using a PACSystems RX3i
Application: 1000 Watt Low Inertia Motor with Brake. Configuration for Controller (Example application requiring (120) 24 VDC inputs and (80) Relay outputs AC power supply)
Qty
Part Number
Description
Controller, I/O and Display
1
IC695CPU310
CPU with two built-in serial ports
1
IC695PSA040
120/240 VAC, 125 VDC Power Supply, current available 9 Amps @ 3.3 VDC; 6 Amps @ 5 VDC; 1.6 Amps @ 24 VDC maximum
1
IC695CHS016
16 Slot Universal Base
4
IC694MDL660
Discrete Input Module, 24 VDC Positive Logic, 32 points (Requires terminal block)
5
IC694MDL940
Discrete Output Module, Relay 2.0 A per point Form A, 16 points (Terminal block included)
4
IC694TBB032
Terminal Block, Box Style
1
IC693DSM314
Servo Motion Module, 4 analog axes supported per module
1
IC693ACC336
DSM Analog Servo Interface Terminal Board
1
IC693CBL324
DSM Analog TB Interface Cable, 1 m (3.28 feet)
1
IC800VMCI010
VersaMotion flying lead I/O interface cable, 1 m (3.28 feet)
Servo Amplifier and Motor
1
IC800VMM10LBKSE25
VersaMotion 1000 Watt Low Inertia Servo Motor with brake. Motor has keyway and oil seal
1
IC800VMA102
Servo Amplifier, 1000 Watts, 220 VAC
1
IC800VMCB1030
Brake and Power Cable for 1000 Watt servo motor with brake, 3 m (9.8 feet)
1
IC800VMCE1030
Encoder Cable for 1000 Watt and greater, 3 m (9.8 feet)
1
IC800VMTBC005
I/O Terminal Block and Cable (0.5 meters)
1
IC800VMCS030
Communications Cable from Servo Driver to PC, 3 m (9.8 feet)
Programming Software for Control, Display and Motion
1
www.ge-ip.com
BC646MPP001
Machine Edition Professional Development Suite with Proficy GlobalCare Complete. Includes VersaMotion configuration tool,
View Development for QuickPanel and PLC Standard with programming cable. Proficy GlobalCare with 15 months of free
upgrades which is renewable on an annual basis.
GE Intelligent Platforms Control Systems Solutions
1.75
Series 90-70
Programmable Controllers
Series 90-70 Specialty PLCs
Utilizing field-proven Series 90-70 PLC,
Genius I/O, and VersaMax I/O products,
GMR (Genius Modular Redundancy)
system is a modular redundancy
system developed by GE, forming a
flexible and powerful safety system
up to and including SIL 3.
GMR contains three subsystems; the
control unit is the PLC subsystem,
and there is an input subsystem
and an output subsystem. All of the
subsystems can be formed to simplex,
duplex or triplex redundancy.
GMR provides advanced and abundant
diagnostic abilities that are easily
programmed by using Proficy Machine
Edition software. The safety system
must be configured using all parts
that are TUV certified, as defined in
the specified configuration of the GMR
documentation.
Racks
CPUs
page 1.77
Power Supplies
page 1.80
I/O Interface Modules
page 1.81
Accessories
page 1.83
pages 1.78-1.79
Communications Modules
page 1.82
Publication Reference Chart
GFK-0262
Series 90-70 Programmable Controller
Installation Manual
GFK-0646
C Programmer’s Toolkit for Series 90-70
PLCs User’s Manual
GFK-0265
Series 90-70 PLC Reference Manual
GFK-0868
GFK-0448
Series 90-70 Programmable Controller
User’s Guide to the Integration of 3rd
Party VME Modules
Series 90 Ethernet Communications
User’s Manual
GFK-1527
Series 90-70 Enhanced Hot Standby CPU
Redundancy User’s Guide
GFK-0582
Series 90 PLC Serial Communications
User’s Manual
GFK-1541
TCP/IP Ethernet Communications for
the Series 90 PLC User’s Manual
GFK-0600
Series 90-70 Programmable Controller
Datasheets Manual
GFK-2017
Series 90-70 Genius Bus Controller
1.76
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-70
CPU
Series 90-70 Genius Modular Redundancy CPU is a single slot programmable controller CPU
that allows floating point calculations. The CPU is programmed and configured with
Windows based programming software for use in Emergency Shut-Down (ESD), fire and gas,
and other critical control applications. It communicates with I/O and smart option modules
over the rack-mounted backplane.
IC697CPM790
Product Name
Central Processing Unit, 64 MHz, 32-Bit, Floating Point,
1 Mbyte On-Board User Memory,
(requires 70 CFM forced air cooling)
Lifecycle Status
Mature
CPU Type
CPU Memory
Redundant (Genius Triple Modular)
1 Mbyte of User Logic RAM
Non-Volatile User Flash Memory
No
Floating Point Math
Yes
Processor Speed
I/O Discrete Points
Boolean Execution Speed
(us/boolean function)
Analog I/O
Embedded Communications
64 MHz
(80486DX2)
12288
0.4
8 Kbytes Input, 8 Kbytes Output
Serial
Protocols Supported
SNP Serial
Built-in Serial Ports
1 (RS-422/485 compatible serial attachment)
Redundancy Featured Scan Extension
Current Required from 5V Bus
www.ge-ip.com
N/A
1.6 Amps
GE Intelligent Platforms Control Systems Solutions
1.77
Series 90-70
Programmable Controllers
Racks
Series 90-70 PLC Racks are available in a variety of configurations to the meet the needs of
your application. The choices vary from 5- and 9-slot Standard Racks, to 9-slot Redundant
Racks and 17-slot VME Integrator Racks, each giving you the option of Front (Rack) Mount or
Rear (Panel) Mount. These racks can be used for CPU, local and remote I/O and accept all
plug-in IC697 Power Supplies. With available accessories, any of these racks can function as
an Expansion Rack, and two racks can be run off a single Power Supply. GE offers standardlength cables for easy installation and provides wiring information for custom applications.
IC697CHS750
IC697CHS770
IC697CHS771
IC697CHS790
Product Name
Standard Series
90-70 Rack,
5-slot, Rear
(Panel) Mount
Redundant Series
90-70 Rack,
9-Slot, Rear
(Panel) Mount
Redundant Series
90-70 Rack,
9-Slot, Front
(Rack) Mount
Standard Series
90-70 Rack,
9-slot, Rear
(Panel) Mount
Lifecycle Status
Mature
Mature
Mature
Mature
Rack Type
Standard 90-70
Redundant 90-70
Redundant 90-70
Standard 90-70
Number of Slots
5 Double Width
(plus one for
power supply)
6 Double Width
(plus one for
power supply)
6 Double Width
(plus one for
power supply)
9 Double Width
(plus one for
power supply)
Rear (Panel)
Rear (Panel)
Front (Rack)
Rear (Panel)
All IC697 PLC
module types
All IC697 PLC module types,
IC687 (VME) I/O and
Communications
module types
All IC697 PLC module types,
IC687 (VME) I/O and
Communications
module types
All IC697 PLC
module types
1.6 inch
1.6 inch
1.6 inch
1.6 inch
Plug-in AC or
DC IC697
Plug-in AC/DC
and DC IC697, or
external power supply
Plug-in AC/DC
and DC IC697, or
external power supply
Plug-in AC or
DC IC697
11.15” x 12.6” x 7.5”
11.15” x 19.00” x 7.5”
11.15” x 19.00” x 7.5”
11.15” x 19.00” x 7.5”
Mounting Location
Rack Configurations
Rack Slot Size
Compatible Power Supplies
Dimensions
1.78
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-70
Racks
Series 90-70 PLC Racks are available in a variety of configurations to the meet the needs of
your application. The choices vary from 5- and 9-slot Standard Racks, to 9-slot Redundant
Racks and 17-slot VME Integrator Racks, each giving you the option of Front (Rack) Mount or
Rear (Panel) Mount. These racks can be used for CPU, local and remote I/O and accept all
plug-in IC697 Power Supplies. With available accessories, any of these racks can function as
an Expansion Rack, and two racks can be run off a single Power Supply. GE offers standardlength cables for easy installation and provides wiring information for custom applications.
IC697CHS791
IC697CHS782
IC697CHS783
Product Name
Standard Series
90-70 Rack,
9-slot, Front
(Rack) Mount
VME Integrator Rack,
17-slot, Rear
(Panel) Mount
VME Integrator Rack,
17-slot, Front
(Rack) Mount
Lifecycle Status
Mature
Mature
Mature
Rack Type
Standard 90-70
VME Integrator
VME Integrator
Number of Slots
9 Double Width
(plus one for
power supply)
17 Single Width,
8 Double Width (plus one
for power supply)
17 Single Width,
8 Double Width (plus one
for power supply)
Front (Rack)
Rear (Panel)
Front (Rack)
All IC697 PLC
module types
All IC697 PLC module types,
3rd party VME
modules with
0.8” spacing
All IC697 PLC module types,
3rd party VME
modules with
0.8” spacing
1.6 inch
0.8 inch
0.8 inch
Plug-in AC or DC IC697
Plug-in AC/DC
and DC IC697, or
external power supply
Plug-in AC/DC
and DC IC697, or
external power supply
11.15” x 19.00” x 7.5”
11.15” x 19.00” x 7.5”
11.15” x 19.00” x 7.5”
Mounting Location
Rack Configurations
Rack Slot Size
Compatible Power Supplies
Dimensions
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.79
Series 90-70
Programmable Controllers
Power Supplies
Series 90-70 Power Supply modules simply slide into the PLC rack just like I/O, and they
work with any Series 90-70 CPU. Available with a variety of power ratings and Input Voltage
Ranges for powering up systems of different sizes, Series 90-70 power supplies also have
built-in protection for autoranging power factor corrections as well as overcurrent and
overvoltage fault conditions. Depending on your application, it is possible to use one
power supply for operation of two racks.
IC697PWR710
IC697PWR711
IC697PWR724
IC697PWR748
Product Name
Power Supply,
120/240 VAC or
125 VDC, 55W
Power Supply,
120/240 VAC or
125 VDC, 100W
Power Supply,
24 VDC, 90W
Power Supply,
48 VDC, 90W
Lifecycle Status
Mature
Mature
Mature
Mature
Module Function
Power Supply
Power Supply
Power Supply
Power Supply
120/240 VAC or
125 VDC
120/240 VAC or
125 VDC
24 VDC
48 VDC
55 Watts; 5 VDC
@ 11 Amps
100 Watts;
5 VDC @ 20 Amps,
+12 VDC @ 2 Amps,
-12 VDC @ 1 Amp
90 Watts;
5 VDC @ 18 Amps,
+12 VDC @ 1.5 Amps,
-12 VDC @ 1 Amp
90 Watts;
5 VDC @ 18 Amps,
+12 VDC @ 1.5 Amps,
-12 VDC @ 1 Amp
Power Source
Output Source
1.80
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-70
I/O Interface Modules
PACSystems and Series 90-70 feature a variety of communications options for distributed
control and/or I/O, supporting a wide range of communication protocols and configurations.
These communication modules are easy to install and quick to configure. Some ­distributed
I/O communications modules allow for numerous remote drops or additional racks, while
others provide an interface for GE products up to 7500 feet away from the controller.
IC697BEM731
IC697BEM713
IC697BEM711
IC697BEM733
Product Name
Genius Bus Controller
Bus Transmitter Module
Bus Receiver Module
Remote I/O Scanner
Lifecycle Status
Active
Mature
Mature
Mature
Bus Controller
Bus Transmitter
Bus Receiver
Remote I/O Scanner
Supports Redundancy
Yes
No
No
Yes
Discrete Points Available
N/A
N/A
N/A
128 Bytes Per Drop
Programmer Effective Data Rate
N/A
500 Kbytes/sec
N/A
N/A
Time to Store 16 Kbyte Program
N/A
20 - 30 Seconds
N/A
N/A
Effective Data Rate
N/A
500 Kbytes/sec
500 Kbytes/sec
38.4 Kbaud
Total Allowed Distance of
Interconnecting Cable
N/A
50 feet
(15 meters)
50 feet
(15 meters)
N/A
Maximum Distance from Controller
N/A
N/A
N/A
7500 feet
(2275 meters)
N/A
Non-isolated differential
communication
Non-isolated differential
communication
N/A
1 (Hand Held Monitor Port)
2 (Programmer Port,
Expansion Port Out)
2 (Expansion Port In,
Expansion Port Out)
2 (RS-422 Compatible Serial
Port, Hand Held Monitor Port)
1.3 Amps
1.4 Amps
0.8 Amp
0.8 Amp
Module Type
Electrical Isolation
Built-in Serial Ports
Current Required from 5V Bus
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.81
Series 90-70
Programmable Controllers
Communications Module
PACSystems and Series 90-70 feature a variety of communications options for distributed
control and/or I/O, supporting a wide range of communication protocols and configurations.
These communication modules are easy to install and quick to configure. Some distributed
I/O communications modules allow for numerous remote drops or additional racks, while
others provide an interface for GE products up to 7500 feet away from the controller.
IC697CMM742
Product Name
Ethernet Interface (Type 2) Module
Lifecycle Status
Mature
Module Type
Ethernet Interface
Supports Redundancy
No
Protocols Supported
SRTP Channels and EGD
Effective Data Rate
19200 bps Serial, 10 Mbps IEEE
Electrical Isolation
N/A
Communications Processor Speed
N/A
Simultaneous Communication Speed
N/A
Individual Communication Speed
N/A
RCM Maximum Cable Length
N/A
Built-in Serial Ports
Current Required from 5V Bus
1.82
5 (RS-232, RS-485, 10BaseT, AUP, 10Base2)
2.0 Amps
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-70
Accessories
IC690ACC901
Miniconverter Kit with cable (RS-232 to RS-485)
Active
IC690CDR002
User Manuals, InfoLink CD-ROM Documentation, Single-user License
Active
IC697ACC700
Terminal Block, 40 Contacts (qty 6)
Mature
IC697ACC701
Replacement Battery for CPU and PCM (qty 2)
Mature
IC697ACC702
I/O Bus Terminator Plug
Mature
IC697ACC715
VME Option Kit, J2 Backplane Mounting
Mature
IC697ACC720
Blank Slot Filler (qty 6)
Mature
IC697ACC721
Rack Fan Assembly, 120VAC
Active
IC697ACC722
VME Backplane Connector, Interrupt Jumper (qty 6)
Mature
IC697ACC723
Clear Plastic Doors (qty 6)
Mature
IC697ACC724
Rack Fan Assembly, 240VAC
Active
IC697ACC726
Top PWA Cover, CPU-style (qty 6)
Mature
IC697ACC727
Top and Bottom PWA Cover, GBC (qty 2)
Mature
IC697ACC728
Top and Bottom PWA Cover, BTM/BTR (qty 2)
Mature
IC697ACC729
Top and Bottom PWA Cover, I/O Link (qty 2)
Mature
IC697ACC730
Spare Slot Terminal Strip Retainer
Mature
IC697ACC732
Top PWA Cover, CPU77x and CPU78x (qty 2)
Mature
IC697ACC736
Cable Shield Clamping Assembly
Active
IC697ACC744
Rack Fan Assembly, 24VDC
Active
IC697MLX000
Series 90-70 Labels Kit
Active
IC600WD002
I/O Expansion Cable, 2 feet (0.6 meters)
Mature
IC600WD005
I/O Expansion Cable, 5 feet (1.5 meters)
Mature
IC600WD010
I/O Expansion Cable, 10 feet (3.0 meters)
Mature
IC600WD025
I/O Expansion Cable, 25 feet (7.5 meters)
Mature
IC600WD050
I/O Expansion Cable, 50 feet (15 meters)
Mature
IC690CBL701
Cables - PCM to IC640 or PC-XT Computer, 10 feet (3 meters)
Active
IC690CBL702
Cables - PCM to PC-AT Computer, 10 feet (3 meters)
Mature
IC690CBL705
Cables - PCM to IC642 or PS/2 Computer, 10 feet (3 meters)
Mature
IC697CBL709
Cable, MAP Controller to Broadband Modem
Mature
IC697CBL811
Cable, RCM Communications (10 feet) I/O Expansion Cable
Mature
IC697CBL826
Cable, RCM Communications (25 feet) I/O Expansion Cable
Mature
I/O Cables
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.83
Series 90-30
Programmable Controllers
Series 90-30 PLCs
The Series 90-30 PLCs are a family of controllers, I/O systems and specialty
­modules designed to meet the demand for versatile industrial solutions. With a
single overall control architecture and modular design, the Series 90-30 is trusted
worldwide in such applications as high speed packaging, ­material handling, complex motion control, water treatment, ­continuous emissions monitoring,
mining, food processing, elevator control, injection molding, and many more.
One reason for the versatility of the Series 90-30 is the large variety of discrete
and analog I/O modules (over 100 modules), as well as specialty modules, that
are available. In addition, GE Intelligent Platforms offer a wide range of high-level
­communication options, from a simple serial connection to a high-speed
Ethernet interface and a number of bus modules.
CPUs
Proficy Machine Edition
Proficy Machine Edition is an
advanced software environment for
the development and maintenance
of machine level automation.
Visualization, motion control, and
execution logic are developed with
a single programmer.
Networks and
Distributed I/O Systems
pages 1.109-1.111
Specialty Modules
pages 1.103-1.108
pages 1.85-1.87
Baseplates
Power Supplies
Serial
Communications Modules
Analog I/O Modules (input) pages 1.94-1.95
Analog I/O Modules
(output)
pages 1.101-1.102
page 1.88
Discrete I/O Modules (input) pages 1.91-1.93
Discrete I/O Modules
(output)
pages 1.96-1.100
pages 1.89-1.90
page 1.112
Power Measurement Modules page 1.113
Pneumatic Module
page 1.114
Motion Modules
pages 1.116-1.117
Expansion Modules
page 1.118
Portable Program
Download Device (PPDD) pages 1.119-1.120
α and βi Series Servo Amplifiers page 1.124
VersaMotion
pages 1.125-1.133
Accessories
pages 1.121-1.122
Configuration Guidelines page 1.123
Publication Reference Chart
GFK-0255
Series 90 Programmable Coprocessor Module &
Support Software User’s Manual
GFK-0772
PCM C Function Library Reference Manual
GFK-1213
Series 90-30 FIP Bus Controller User’s Manual
GFK-0781
Power Mate APM for Series 90-30 PLC Follower
Mode User’s Manual
GFK-1256
Power Mate for Series 90-30 User’s Manual
GFK-1322
Series 90-30 PLC LonWorks Bus Interface
Module User’s Manual
GFK-0293
Series 90-30 High Speed Counter User’s Manual
GFK-0356
Series 90-30 PLC Installation and Hardware Manual
GFK-0814
GFK-0412
Series 90-30 Genius Communications Module
User’s Manual
C Programmer’s Toolkit for Series 90 PCM Quick
Reference Guide
GFK-1411
Series 90-30 System Manual for Windows® Users
GFK-0823
Series 90-30 I/O Link Master Module User’s Manual
GFK-1464
GFK-0828
Series 90-30 Diagnostic System User’s Guide
Motion Mate DSM302 for Series 90-30 PLCs
User’s Manual
GFK-0840
Power Mate APM for Series 90-30 PLC Standard
Mode User’s Manual
GFK-1466
Temperature Control Module for the Series 90-30
PLC User’s Manual
GFK-0467
Series 90-30/20/Micro PLC CPU Instruction Set
Reference Manual
GFK-0529
Series 90 PLC SNP Communications User’s Manual
GFK-0582
Series 90 PLC Serial Communications Driver
User’s Manual
GFK-0854
Series 90 Sequential Function Chart Programming
Language User’s Manual
GFK-1541
TCP/IP Ethernet Communications for the Series 90
PLC User’s Manual
GFK-0585
Series 90 PLC SNP Communications Driver
User’s Manual
GFK-0898
Series 90-30 PLC I/O Module Specifications Manual
GFK-1734
GFK-1028
Series 90-30 I/O Processor Module User’s Manual
Power Transducer for the Series 90-30 PLC
User’s Manual
GFK-0631
Series 90-30 I/O Link Slave Interface User’s Manual
GFK-1034
Series 90-30 Genius Bus Controller User’s Manual
GFK-1868
Proficy Machine Edition Getting Started Guide
GFK-0664
Series 90-30 Axis Positioning Module
(Power Mate-APM) Programmer’s Manual
GFK-1037
Series 90-30 FIP Remote I/O Scanner User’s Manual
GFK-2121
Series 90-30 Profibus Modules User’s Manual
GFK-1056
Series 90-30 State Logic Control System
User’s Manual
GFS-062
Series 90-30 Quick Reference Guide for
Maintenance
GFK-1084
TCP/IP Ethernet Communications for the Series
90-30 PLC User’s Manual
GFZ-0085
Series 90-30 Troubleshooting Pocket Guide
GFK-0695
Series 90-30 Enhanced Genius Communications
Module User’s Manual
GFK-0712
Series 90 Digital Event Recorder User’s Manual
GFK-0726
State Logic Processor for Series 90-30 PLC
User’s Guide
GFK-1179
Installation Requirements for Conformance
to Standards
GFK-0771
C Programmer’s Toolkit for Series 90 PCMs
User’s Manual
GFK-1186
TCP/IP Ethernet Communications for the Series 90
PLC Station Manager Manual
1.84
GE Intelligent Platforms Control Systems Solutions
IC690CDU002 InfoLink for PLC CD-ROM
www.ge-ip.com
Programmable Controllers
Series 90-30
CPUs
For entry-level applications with low I/O counts, the CPU is embedded into the backplane, making all
slots available for I/O. These modules are compatible with advanced modules such as Ethernet, various
bus modules, and control. Mid-range CPU models are modular and come in various memory sizes,
­performance capability and increased functionality such as overrides, battery-backed clock and
Programmable Coprocessor module support. The high-performance CPUs are based on the latest
386EX processor for fast computation and high throughput. They can handle up to 4,096 I/O and
start at 32K of memory and are programmable in a number of standard languages.
IC693CPU311
IC693CPU313
IC693CPU323
IC693CPU350
IC693CPU360
Product Name
5-slot Baseplate
(Model 311)
5-slot Baseplate
(Model 313)
10-slot Baseplate
(Model 323)
CPU (Model 350)
CPU (Model 360)
Lifecycle Status
Active
Active
Active
Active
Active
I/O Base with
built-in CPU
I/O Base with
built-in CPU
I/O Base with
built-in CPU
CPU Module
CPU Module
Boolean Execution Speed (ms/K)
18
0.6
0.6
0.22
0.22
User Logic Memory (K bytes)
6
12
12
74
240
Real Time Clock
No
No
No
Yes
Yes
I/O Discrete Points
160
160
320
4096
4096
I/O Analog Points
64 In / 32 Out
64 In / 32 Out
64 In / 32 Out
2048 In / 512 Out
2048 In / 512 Out
RAM, EPROM, EEPROM
RAM, EPROM, EEPROM
RAM, EPROM, EEPROM
RAM, Flash
RAM, Flash
Module Type
Type of Memory Storage
Processor Speed (MHz)
Built-in Communication Ports
Total Number of Racks
Communications Option Modules
Field Busses/Device Networks
Software Programming Support
Internal Power Used
www.ge-ip.com
N/A
N/A
N/A
N/A
N/A
One RS-485 port on
power supply.
Supports SNP
One RS-485 port on
power supply.
Supports SNP
One RS-485 port on
power supply.
Supports SNP
One RS-485 port on
power supply.
Supports SNP
One RS-485 port on
power supply.
Supports SNP
8
8
1 (CPU built in)
1 (CPU built in)
1 (CPU built in)
Serial-SNP and RTU,
LAN-Genius, Ethernet
SRTP and Ethernet
Modbus TCP
Ethernet, Genius,
Profibus-DP, DeviceNet,
Interbus-S, CsCAN
Logicmaster (DOS),
VersaPro (Windows),
Proficy Logic Developer Machine Edition
Serial-SNP and RTU,
LAN-Genius, Ethernet
SRTP and Ethernet
Modbus TCP
Ethernet, Genius,
Profibus-DP, DeviceNet,
Interbus-S, CsCAN
Logicmaster (DOS),
VersaPro (Windows),
Proficy Logic Developer
-Machine Edition
Serial-SNP and RTU,
LAN-Genius, Ethernet
SRTP and Ethernet
Modbus TCP
Ethernet, Genius,
Profibus-DP, DeviceNet,
Interbus-S, CsCAN
Logicmaster (DOS),
VersaPro (Windows),
Proficy Logic Developer
-Machine Edition
410 mA @ 5 VDC
430 mA @ 5 VDC
430 mA @ 5 VDC
Serial-SNP, SNPX, RTU
Serial-SNP, SNPX, RTU
and CCM, LAN-Genius, and CCM, LAN-Genius,
Ethernet SRTP and
Ethernet SRTP and
Ethernet Modbus TCP
Ethernet Modbus TCP
Ethernet, Genius,
Ethernet, Genius,
Profibus-DP, DeviceNet, Profibus-DP, DeviceNet,
Interbus-S, CsCAN
Interbus-S, CsCAN
Logicmaster (DOS),
Logicmaster (DOS),
VersaPro (Windows),
VersaPro (Windows),
Proficy Logic Developer Proficy Logic Developer
-Machine Edition
-Machine Edition
670 mA @ 5 VDC
670 mA @ 5 VDC
GE Intelligent Platforms Control Systems Solutions
1.85
Series 90-30
Programmable Controllers
CPUs
For entry-level applications with low I/O counts, the CPU is embedded into the backplane, making all
slots available for I/O. These modules are compatible with advanced modules such as Ethernet, various
bus modules, and control. Mid-range CPU models are modular and come in various memory sizes,
­performance capability and increased functionality such as overrides, battery-backed clock and
Programmable Coprocessor module support. The high-performance CPUs are based on the latest
386EX processor for fast computation and high throughput. They can handle up to 4,096 I/O and
start at 32K of memory and are programmable in a number of standard languages.
Product Name
Lifecycle Status
IC693CPU363
IC693CPU366
IC693CPU367
CPU (Model 363)
CPU (Model 366 with
built-in Profibus Master)
CPU (Model 367 with
built-in Profibus Slave)
Active
Active
Mature
CPU Module
CPU Module
CPU Module
Boolean Execution Speed (ms/K)
0.22
0.22
0.22
User Logic Memory (K bytes)
240
240
240
Real Time Clock
Yes
Yes
Yes
I/O Discrete Points
4096
4096
4096
I/O Analog Points
2048 In / 512 Out
2048 In / 512 Out
2048 In / 512 Out
RAM, Flash
RAM, Flash
RAM, Flash
Module Type
Type of Memory Storage
Processor Speed (MHz)
Built-in Communication Ports
Total Number of Racks
Communications Option Modules
Field Busses/Device Networks
Software Programming Support
Internal Power Used
1.86
N/A
N/A
N/A
Three total. One RS-485 port on power
supply, one RS-232 and one RS-485 port
on CPU. Supports SNP, RTU Master and
Slave, Serial Read and Write
One Profibus DP Slave port and RS-485
port on power supply. Supports SNP.
One Profibus DP Master, Class 1 V0 port
and RS-485 port on power supply.
Supports SNP.
8
8
8
Serial-SNP, SNPX, RTU and CCM,
LAN-Genius, Ethernet SRTP and
Ethernet Modbus TCP
Serial-SNP, SNPX, RTU and CCM,
LAN-Genius, Ethernet SRTP and
Ethernet Modbus TCP
Serial-SNP, SNPX, RTU and CCM,
LAN-Genius, Ethernet SRTP and
Ethernet Modbus TCP
Ethernet, Genius, Profibus-DP, DeviceNet,
Interbus-S, CsCAN
Ethernet, Genius, Profibus-DP, DeviceNet,
Interbus-S, CsCAN
Ethernet, Genius, Profibus-DP, DeviceNet,
Interbus-S, CsCAN
Logicmaster (DOS),
VersaPro (Windows), Proficy Logic
Developer - Machine Edition
Proficy Logic Developer
- Machine Edition
Proficy Logic Developer
-Machine Edition
890 mA @ 5 VDC
940 mA @ 5 VDC
940 mA @ 5 VDC
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
CPUs
For entry-level applications with low I/O counts, the CPU is embedded into the backplane, making all
slots available for I/O. These modules are compatible with advanced modules such as Ethernet, various
bus modules, and control. Mid-range CPU models are modular and come in various memory sizes,
­performance capability and increased functionality such as overrides, battery-backed clock and
Programmable Coprocessor module support. The high-performance CPUs are based on the latest
386EX processor for fast computation and high throughput. They can handle up to 4,096 I/O and
start at 32K of memory and are programmable in a number of standard languages.
IC693CPU370
IC693CPU372
IC693CPU374 PLUS
Product Name
CPU (Model 370).
Requires High Capacity
Power Supply
CPU (Model 372 with
built-in 10/100 Mbps
Ethernet and WEB Enabled).
Requires High Capacity
Power Supply
CPU (Model 374 PLUS with
built-in 10/100 Mbps
Ethernet and Web Enabled).
Requires High Capacity
Power Supply
Lifecycle Status
Active
Active
Active
CPU Module
CPU Module
CPU Module
Boolean Execution Speed (ms/K)
0.15
0.15
0.15
User Logic Memory (K bytes)
240
120
240
Real Time Clock
Yes
Yes
Yes
I/O Discrete Points
4096
4096
4096
I/O Analog Points
2048 In / 512 Out
2048 In / 512 Out
2048 In / 512 Out
RAM, Flash
RAM, Flash
RAM, Flash
133Mhz
133Mhz
133Mhz
One RS-485 port
on power supply.
Supports SNP
One RS-485 port
on power supply.
Supports SNP and two
Ethernet ports;
(one IP address) on CPU,
10/100 Mbps built-in switch,
SRTP - channels
(Producer and Consumer);
EGD, Modbus TCP Client/Server
and Web Diagnostics Support
One RS-485 port
on power supply.
Supports SNP and two
Ethernet ports;
(one IP address) on CPU,
10/100 Mbps built-in switch,
SRTP - channels
(Producer and Consumer);
EGD, Modbus TCP Client/Server
and Web Diagnostics Support
Module Type
Type of Memory Storage
Processor Speed (MHz)
Built-in Communication Ports
Total Number of Racks
Communications Option Modules
Field Busses/Device Networks
Software Programming Support
Internal Power Used
www.ge-ip.com
8
8
8
Serial-SNP, SNPX, RTU and CCM,
LAN-Genius, Ethernet SRTP and
Ethernet Modbus TCP Client/Server
Ethernet, Genius, Profibus-DP,
DeviceNet, Interbus-S, CsCAN
Proficy Logic Developer
- Machine Edition
Serial-SNP, SNPX, RTU and CCM,
LAN-Genius, Ethernet SRTP and
Ethernet Modbus TCP Client/Server
Ethernet, Genius, Profibus-DP,
DeviceNet, Interbus-S, CsCAN
Proficy Logic Developer
- Machine Edition
Serial-SNP, SNPX, RTU and CCM,
LAN-Genius, Ethernet SRTP and
Ethernet Modbus TCP Client/Server
Ethernet, Genius, Profibus-DP,
DeviceNet, Interbus-S, CsCAN
Proficy Logic Developer
-Machine Edition
1.4 Amps @ 5 VDC
1.4 Amps @ 5 VDC
1.4 Amps @ 5 VDC
GE Intelligent Platforms Control Systems Solutions
1.87
Series 90-30
Programmable Controllers
Baseplates
Series 90-30 baseplates are available in 5- and 10-slot configurations to the meet the needs
of your application. You can choose expansion or remote baseplates for multi-rack systems,
covering distances of up to 700 feet from the CPU. GE offers standard length cables for
easy installation and provides wiring information for custom applications.
IC693CHS391
IC693CHS392
IC693CHS393
IC693CHS397
IC693CHS398
IC693CHS399
Product Name
10-slot CPU
Baseplate
(Model 331
and above)
10-slot
Expansion
Baseplate
(Model 331
and above)
10-slot Remote
Baseplate
(Model 331
and above)
5-slot CPU
Baseplate
(Model 331
and above)
5-slot Expansion
Baseplate
(Model 331
and above)
5-slot Remote
Baseplate
(Model 331
and above)
Lifecycle Status
Active
Active
Active
Active
Active
Active
Module Type
CPU I/O Base
Expansion I/O Base Expansion I/O Base
CPU I/O Base
Expansion I/O Base Expansion I/O Base
Main (With
CPU Slot)
Expansion
Expansion
Main (With
CPU Slot)
Expansion
Expansion
Distance
N/A
Up to 50 feet
Up to 700 feet
N/A
Up to 50 feet
Up to 700 feet
Number of Slots
10
10
10
5
5
5
17.44 x 5.12 x 5.59
(443 x 130 x 142)
17.44 x 5.12 x 5.59
(443 x 130 x 142)
17.44 x 5.12 x 5.59
(443 x 130 x 142)
10.43 x 5.12 x 5.59
(245 x 130 x 142)
10.43 x 5.12 x 5.59
(245 x 130 x 142)
10.43 x 5.12 x 5.59
(245 x 130 x 142)
420 mA @ 5 VDC
150 mA @ 5 VDC
460 mA @ 5 VDC
270 mA @ 5 VDC
170 mA @ 5 VDC
480 mA @ 5 VDC
Baseplate Option
Dimension (W x H x D) in. (mm)
Internal Power Used
1.88
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Power Supplies
The Series 90-30 power supply modules simply snap in just like I/O, and they work with any
model CPU. Each version provides auto-ranging so there is no need to set jumpers for different incoming power levels, and they are current limiting so a direct short will shut the power
supply down to avoid damage to the hardware. Series 90-30 power supplies are tied into
the performance of the CPU for simplex, fail-safe, and fault tolerance. Advanced diagnostics
and built-in smart switch fusing are among the other performance and safety features.
IC693PWR321
IC693PWR330
IC693PWR331
IC693PWR332
Product Name
Power Supply,
120/240 VAC, 125 VDC
Power Supply,
120/240 VAC, 125 VDC
Power Supply,
24 VDC
Power Supply,
12 VDC
Lifecycle Status
Active
Active
Active
Active
Module Type
Power Supply
Power Supply
Power Supply
Power Supply
Power Source
100-240 VAC or 125 VDC
100-240 VAC or 125 VDC
24 VDC
12 VDC
High Capacity
No
Yes
Yes
Yes
Output Source
30 watts total; 15 watts 5 V;
15 watts 24 V relay;
20 watts 24 V isolated
30 watts total; 30 watts 5 V;
15 watts 24 V relay;
20 watts 24 V isolated
30 watts total; 30 watts 5 V;
15 watts 24 V relay;
20 watts 24 V isolated
30 watts total; 30 watts 5 V;
15 watts 24 V relay;
20 watts 24 V isolated
Number of Redundant
Power Supplies Supported
N/A
N/A
N/A
N/A
Cable Length to Redundant
Power Supply Adapter
N/A
N/A
N/A
N/A
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.89
Series 90-30
Programmable Controllers
Power Supplies
The Series 90-30 power supply modules simply snap in just like I/O, and they work with any
model CPU. Each version provides auto-ranging so there is no need to set jumpers for different incoming power levels, and they are current limiting so a direct short will shut the power
supply down to avoid damage to the hardware. Series 90-30 power supplies are tied into
the performance of the CPU for simplex, fail-safe, and fault tolerance. Advanced diagnostics
and built-in smart switch fusing are among the other performance and safety features.
IC693PWR328
Product Name
Power Supply, 48 VDC
Lifecycle Status
Active
Module Type
Power Supply
Power Source
48 VDC
High Capacity
No
Output Source
30 watts total; 15 watts 5 V;
15 watts 24 V relay;
20 watts 24 V isolated
Number of Redundant
Power Supplies Supported
N/A
Cable Length to Redundant
Power Supply Adapter
N/A
1.90
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Discrete I/O Modules (Input)
Input modules provide the interface between the PLC and external input devices such as
proximity sensors, push buttons, switches, and BCD thumbwheels. Output modules provide
the interface between the PLC and external output devices such as contactors, interposing
relays, BCD displays and indicator lamps. GE offers a variety of modules that support
different voltage ranges and types, current capacity, isolation and response time to
meet your application needs.
IC693ACC300
IC693MDL230
IC693MDL250
IC693MDL231
IC693MDL240
Product Name
DC Voltage Input Simulator,
8/16 Points
AC Voltage Input Module,
120 VAC Isolated,
8 Point Input
AC Voltage Input Module,
120 VAC Isolated,
16 Point Input
AC Voltage Input Module,
240 VAC Isolated,
8 Point Input
AC Voltage Input Module,
120 VAC,
16 Point Input
Lifecycle Status
Active
Active
Active
Active
Active
Module Type
Input Simulator
Discrete Input
Discrete Input
Discrete Input
Discrete Input
Power Type
DC
AC
AC
AC
AC
Input Voltage Range
N/A
0-132 VAC
0-132 VAC
0-264 VAC
0-132 VAC
Input Current (mA)
N/A
14.5
14.5
15
12
Number of points
16
8
16
8
16
20 on/30 off
30 on/45 off
30 on/45 off
30 on/45 off
30 on/45 off
Trigger Voltage
N/A
74-132
74-132
148-264
74-132
Points per Common
16
1
1
1
16
Toggle Switches
Terminal Block (20 screws),
included with module.
IC694TBBx32 or
IC694TBSx32.
Sold Separately.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
120 mA @ 5 VDC
60 mA @ 5 VDC
60 mA @ 5 VDC
60 mA @ 5 VDC
90 mA @ 5 VDC
Response Time (ms)
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.91
Series 90-30
Programmable Controllers
Discrete I/O Modules (Input)
Input modules provide the interface between the PLC and external input devices such as
proximity sensors, push buttons, switches, and BCD thumbwheels. Output modules provide
the interface between the PLC and external output devices such as contactors, interposing
relays, BCD displays and indicator lamps. GE offers a variety of modules that support
different voltage ranges and types, current capacity, isolation and response time to
meet your application needs.
IC693MDL260
IC693MDL241
IC693MDL632
IC693MDL634
IC693MDL645
Product Name
AC Voltage Input Module,
120 VAC, 32 Point Input
AC/DC Voltage Input
Module, 24 VAC/VDC
DC Voltage Input Module,
125 VDC Pos/Neg Logic,
8 Point Input
DC Voltage Input Module,
24 VDC Pos/Neg Logic,
8 Point Input
DC Voltage Input Module,
24 VDC Pos/Neg Logic,
16 Point Input
Lifecycle Status
Active
Active
Active
Active
Active
Module Type
Discrete Input
Discrete Input
Discrete Input
Discrete Input
Discrete Input
Power Type
AC
Mixed
DC
DC
DC
0-132 VAC
0-30 VDC
0-150 VDC
0-30 VDC
0-30 VDC
Input Current (mA)
12
7
4.5
7
7
Number of points
32
16
8
8
16
30 on/45 off
12 on/28 off
7 on/7 off
7 on/7 off
7 on/7 off
74-132
11.5-30
90-150
11.5-30
11.5-30
32
16
4
8
16
IC694TBBx32 or
IC694TBSx32.
Sold Separately.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
90 mA @ 5 VDC
80 mA @ 5 VDC;
125 mA @ 24 VDC Isolated
40 mA @ 5 VDC
45 mA @ 5 VDC;
62 mA @ 24 VDC Isolated
80 mA @ 5 VDC;
125 mA @ 24 VDC Isolated
Input Voltage Range
Response Time (ms)
Trigger Voltage
Points per Common
Connector Type
Internal Power Used
1.92
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Discrete I/O Modules (Input)
Input modules provide the interface between the PLC and external input devices such as
proximity sensors, push buttons, switches, and BCD thumbwheels. Output modules provide
the interface between the PLC and external output devices such as contactors, interposing
relays, BCD displays and indicator lamps. GE offers a variety of modules that support
different voltage ranges and types, current capacity, isolation and response time to
meet your application needs.
IC693MDL646
IC693MDL648
IC693MDL654
IC693MDL655
IC693MDL660
Product Name
DC Voltage Input Module,
24 VDC Pos/Neg Logic, FAST,
16 Point Input
DC Voltage Input Module,
48 VDC Pos/Neg Logic,
FAST, 16 Point Input
DC Voltage Input Module,
5/12 VDC (TTL) Pos/Neg
Logic, 32 Point Input
DC Voltage Input Module,
24 VDC Pos/Neg Logic,
32 Point Input
DC Voltage Input Module,
24 VDC Pos/Neg Logic,
32 Point Input
Lifecycle Status
Active
Active
Active
Active
Active
Module Type
Discrete Input
Discrete Input
Discrete Input
Discrete Input
Discrete Input
Power Type
DC
DC
DC
DC
DC
0-30 VDC
0-60 VDC
0-15 VDC
0-30 VDC
0-30 VDC
Input Current (mA)
7
4.2
3.0 @ 5 V, 8.5 @ 12 V
7
7
Number of points
16
16
32
32
32
1 on/1 off
1 on/1 off
1 on/1 off
2 on/2 off
0.5ms, 1.0ms, 2.0ms, 5ms,
10ms, 50ms and 100ms,
selectable per module.
On and off.
11.5-30
34 - 60
4.2-15
11.5-30
11.5-30
16
16
8
8
8
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Fujitsu Connector
Fujitsu Connector
IC694TBBx32 or
IC694TBSx32.
Sold Separately.
80 mA @ 5 VDC;
125 mA @ 24 VDC Isolated
80 mA @ 5 VDC;
125 mA @ 24 VDC Isolated
5 VDC - 195 mA @ 5 VDC;
12 VDC - 440 mA @ 5 VDC
195 mA @ 5 VDC
300 mA @ 5 VDC
Input Voltage Range
Response Time (ms)
Trigger Voltage
Points per Common
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.93
Series 90-30
Programmable Controllers
Analog I/O Modules (Input)
GE offers easy-to-use analog modules for control processes such as flow, ­temperature
and pressure.
IC693ALG220
IC693ALG221
IC693ALG222
IC693ALG223
Product Name
Analog Input, Voltage,
4 Channel
Analog Input, Current,
4 Channel
Analog Input, Voltage,
High Density
(16 Channel)
Analog Input, Current,
High Density
(16 Channel)
Lifecycle Status
Active
Active
Active
Active
Analog Input
Analog Input
Analog Input
Analog Input
1500 volts RMS field
to logic side
1500 volts RMS field
to logic side
1500 volts RMS field
to logic side
1500 volts RMS field
to logic side
-10 V to +10 V
4-20 mA, 0-20 mA
-10 V to +10 V, 0 to 10 V
0-20 mA, 4-20 mA
4
4
16
16
4 ms all channels
2 ms all channels
13 ms all channels
13 ms all channels
12 bit; 5 mV/20 µA/bit
12 bit; 0-20 mA, 5 µA/bit;
4-20 mA, 4 µA/bit
12 bit; ±10 V, 5 mV/20 µA/bit;
0-10 V, 5 mV/20 µA/bit
12 bit; 0-20 mA, 5 µA/bit;
4-20 mA, 4 µA/bit;
4-20 mA Enhanced, 5µA/bit
±10 mV/40 µA at 25ºC (77ºF)
0.1 % full scale
0.25% at 25ºC (77ºF)
0.25% at 25ºC (77ºF)
>9 Megohms
250 ohms
250 ohms
250 ohms
17 Hz
325 Hz
200 Hz
200 Hz
Terminal Block (20 screws), included
with module.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
27 mA @ 5 VDC;
98 mA 24 VDC Isolated
25 mA @ 5 VDC;
100 mA @ 24 VDC Isolated
112 mA @ 5 VDC;
4150 mA -User Supplied 24 VDC
120 mA @ 5 VDC;
65 mA-User Supplied 24 VDC
Module Type
Isolation
Range
Number of Channels
Update Rate
Resolution
Accuracy
Input Impedance
Input Filter Response
Connector Type
Internal Power Used
1.94
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Analog I/O Modules (Input)
GE offers easy-to-use analog modules for control processes such as flow, ­temperature
and pressure.
HE693ADC410
HE693ADC420
Isolated Analog Input Module,
Voltage, 1500 VAC, Isolation
Isolated Analog Input Module,
Current, 1500 VAC, Isolation
Active
Active
Analog Input
Analog Input
±10 V
4-20 mA, ±20 mA
4
4
1500 VAC (RMS), ±2000 VDC
1500 VAC (RMS), ±2000 VDC
1 Megohm
100 ohms
Integrating, 18 bits
Integrating, 18 bits
13 bits plus sign
13 bits plus sign
I/O Required
4 %AI, 4 %AQ, 16 %I
8 %AI, 8 %AQ, 16 %I
Sample Rate
45 channels/second
45 channels/second
Analog Filtering
1 KHz, 3 pole Bessel
1 KHz, 3 pole Bessel
Digital Filtering
1-128 samples/update
1-128 samples/update
Maximum Error
.05% full scale
.05% full scale
1500 VAC (RMS), ±2000 VDC
1500 VAC (RMS), ±2000 VDC
>100 dB
>100 dB
0.7 W @ 5 V, 1.2 W @ 24 V
0.7 W @ 5 V, 1.2 W @ 24 V
Terminal Block (20 screws), included with module.
Terminal Block (20 screws), included with module.
140 mA @ 5 VDC ; 50 mA @ 24 VDC Relay
140 mA @ 5 VDC; 50 mA @ 24 VDC Relay
Product Name
Lifecycle Status
Module Type
Range
Number of Channels
Channel-to-Channel Isolation
Input Impedance
A/D Type, Resolution
Useable Resolution
Common Mode Range
Common Mode Rejection
Power Consumption at Steady State,
Maximum
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.95
Series 90-30
Programmable Controllers
Discrete I/O Modules (Output)
Input modules provide the interface between the PLC and external input devices such as
proximity sensors, push buttons, switches, and BCD thumbwheels. Output modules provide
the interface between the PLC and external output devices such as contactors, interposing
relays, BCD displays and indicator lamps. GE offers a variety of modules that support
different voltage ranges and types, current capacity, isolation and response time to
meet your application needs.
Product Name
Lifecycle Status
Power Type
IC693MDL310
IC693MDL330
IC693MDL340
IC693MDL390
IC693MDL350
IC693MDL730
AC Voltage Output
Module, 120 VAC,
0.5 A, 12 Point Output
AC Voltage Output
Module, 120/240 VAC,
1 A, 8 Point Output
AC Voltage Output
Module, 120 VAC,
0.5 A, 16 Point Output
AC Voltage Output
Module, 120/240 VAC
Isolated,
2 A, 5 Point Output
AC Voltage Output
Module, 120 VAC
Isolated,
2 A, 16 Point Output
DC Voltage Output
Module, 12/24 VDC
Positive Logic,
2 A, 8 Point Output
Discontinued
Active
Active
Active
Active
Active
AC
AC
AC
AC
AC
DC
85-132 VAC
85-264 VAC
85-132 VAC
85-264 VAC
74-264 VAC
12-24 VDC
Number of Points
12
8
16
5
16
8
Isolation
N/A
N/A
N/A
Yes
Yes
N/A
0.5 A
1.0 A
0.5 A
2.0 A
Per Point 2A max. @
30°C & 1A max. @ 60°C
(Linear derating)
2.0 A
1 on 1/2 cy off
1 on 1/2 cy off
1 on 1/2 cy off
1 on 1/2 cy off
1 on 1/2 cy off
2 on/2 off
Output Type
Triac
Triac
Triac
Triac
Triac
Transistor
Polarity
N/A
N/A
N/A
N/A
N/A
Positive
6
4
4
1
1
8
Terminal Block
(20 screws),
included with module.
Terminal Block
(20 screws),
included with module.
Terminal Block
(20 screws),
included with module.
Terminal Block
(20 screws),
included with module.
IC694TBBx32 or
IC694TBSx32.
Sold Separately.
Terminal Block
(20 screws),
included with module.
210 mA @ 5 VDC
160 mA @ 5 VDC
315 mA @ 5 VDC
110 mA @ 5 VDC
110 mA @ 5 VDC
55 mA @ 5 VDC
Output Voltage Range
Load Current
per Point
Response Time (ms)
Points per Common
Connector Type
Internal Power Used
1.96
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Discrete I/O Modules (Output)
Input modules provide the interface between the PLC and external input devices such as
proximity sensors, push buttons, switches, and BCD thumbwheels. Output modules provide
the interface between the PLC and external output devices such as contactors, interposing
relays, BCD displays and indicator lamps. GE offers a variety of modules that support
different voltage ranges and types, current capacity, isolation and response time to
meet your application needs.
Product Name
Lifecycle Status
Power Type
IC693MDL731
IC693MDL732
IC693MDL733
IC693MDL734
IC693MDL740
IC693MDL741
DC Voltage Output
Module, 12/24 VDC
Negative Logic,
2 A, 8 Point Output
DC Voltage Output
Module, 12/24 VDC
Positive Logic,
0.5 A, 8 Point Output
DC Voltage Output
Module, 12/24 VDC
Negative Logic,
0.5 A, 8 Point Output
DC Voltage Output
Module, 125 VDC
Pos/Neg Logic,
6 Point Output
DC Voltage Output
Module, 12/24 VDC
Positive Logic,
0.5 A, 16 Point Output
DC Voltage Output
Module, 12/24 VDC
Negative Logic,
0.5 A, 16 Point Output
Active
Active
Active
Active
Active
Active
DC
DC
DC
DC
DC
DC
12-24 VDC
12-24 VDC
12-24 VDC
11-150 VDC
12-24 VDC
12-24 VDC
8
8
8
6
16
16
N/A
N/A
N/A
N/A
N/A
N/A
2.0 A
0.5 A
0.5 A
1.0 A
0.5 A
0.5 A
2 on/2 off
2 on/2 off
2 on/2 off
7 on/5 off
2 on/2 off
2 on/2 off
Output Type
Transistor
Transistor
Transistor
Transistor
Transistor
Transistor
Polarity
Negative
Positive
Negative
Positive/Negative
Positive
Negative
8
8
8
1
8
8
Terminal Block
(20 screws),
included with module.
Terminal Block
(20 screws),
included with module.
Terminal Block
(20 screws),
included with module.
Terminal Block
(20 screws),
included with module.
Terminal Block
(20 screws),
included with module.
Terminal Block
(20 screws),
included with module.
55 mA @ 5 VDC
50 mA @ 5 VDC
55 mA @ 5 VDC
90 mA @ 5 VDC
110 mA @ 5 VDC
110 mA @ 5 VDC
Output Voltage Range
Number of Points
Isolation
Load Current
per Point
Response Time (ms)
Points per Common
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.97
Series 90-30
Programmable Controllers
Discrete I/O Modules (Output)
Input modules provide the interface between the PLC and external input devices such as
proximity sensors, push buttons, switches, and BCD thumbwheels. Output modules provide
the interface between the PLC and external output devices such as contactors, interposing
relays, BCD displays and indicator lamps. GE offers a variety of modules that support
different voltage ranges and types, current capacity, isolation and response time to
meet your application needs.
IC693MDL742
IC693MDL748
DC Voltage Output
Module, 12/24 VDC
Positive Logic ESCP,
1 A, 16 Point Output
DC Voltage Output
Module, 48/24 VDC
Positive Logic,
0.5 A, 8 Point Output
Active
Active
Active
DC
DC
12-24 VDC
Number of Points
Isolation
Product Name
Lifecycle Status
Power Type
IC693MDL752
IC693MDL753
IC693MDL754
IC693MDL930
DC Voltage Output
Module, 12/24 VDC
Positive Logic,
0.75 A, with ESCP
protection,
32 Point Output
AC/DC Voltage Output
Module, Relay, N.O., 4
A Isolated,
8 Point Output
Active
Active
Active
DC
DC
DC
Mixed
24-48 VDC
5, 12-24 VDC
12-24 VDC
12-24 VDC
0 to 125 VDC,
5/24/125 VDC nominal
0 to 265 VAC
(47 to 63Hz),
120/240 VAC nominal
16
8
32
32
32
8
N/A
N/A
N/A
N/A
N/A
Yes
1.0 A
0.5 A
0.5 A
0.5 A
0.75 A with ESCP
protection
4.0 A
2 on/2 off
2 on/2 off
0.5 on/0.5 off
0.5 on/0.5 off
0.5 on/0.5 off
15 on/15 off
Transistor
Transistor
Transistor
Transistor
Transistor
Relay
Positive
Positive
Negative
Positive
Positive
N/A
8
8
8
8
16
1
Terminal Block
(20 screws),
included with module.
Terminal Block
(20 screws),
included with module.
Fujitsu Connector
Fujitsu Connector
IC694TBBx32 or
IC694TBSx32.
Sold Separately.
Terminal Block
(20 screws),
included with module.
130 mA @ 5 VDC
110 mA @ 5 VDC
260 mA @ 5 VDC
260 mA @ 5 VDC
300 mA @ 5 VDC
6 mA @ 5 VDC;
70 mA @ 24 VDC Relay
DC Voltage Output
DC Voltage Output
Module, 5/24 VDC
Module, 12/24 VDC
(TTL) Negative Logic,
Positive Logic,
0.5 A, 32 Point Output 0.5 A, 32 Point Output
Output Voltage Range
Load Current
per Point
Response Time (ms)
Output Type
Polarity
Points per Common
Connector Type
Internal Power Used
1.98
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Discrete I/O Modules (Output)
Input modules provide the interface between the PLC and external input devices such as
proximity sensors, push buttons, switches, and BCD thumbwheels. Output modules provide
the interface between the PLC and external output devices such as contactors, interposing
relays, BCD displays and indicator lamps. GE offers a variety of modules that support
different voltage ranges and types, current capacity, isolation and response time to
meet your application needs.
IC693MDL916
IC693MDL931
IC693MDL940
IC693MAR590
IC693MDR390
AC/DC Voltage Output
Module, Relay, N.O.,
4 A Isolated,
16 Point Output
AC/DC Voltage Output
Module, Relay, N.C.
and Form C,
8 A Isolated,
8 Point Out
AC/DC Voltage Output
Module, Relay, N.O.,
2 A, 16 Point Output
AC/DC Voltage
I/O Module,
AC In/Relay Out N.O.
AC/DC Voltage Output
Module, 24 VDC Input,
Relay Output, 8 In/8 Out
Lifecycle Status
Active
Active
Active
Active
Active
Power Type
Mixed
Mixed
Mixed
Mixed
Mixed
5 – 125 VDC,
5/24/125 VDC nominal
5 – 250 VAC
(47 to 63 Hz),
120-240 VAC nominal
0 to 125 VDC,
5/24/125 VDC nominal
0 to 265 VAC
(47 to 63Hz),
120/240 VAC nominal
0 to 125 VDC,
5/24/125 VDC nominal
0 to 265 VAC
(47 to 63Hz),
120/240 VAC nominal
5-250 VAC/5-30 VDC
0 to 125 VDC,
5/24/125 VDC nominal
0 to 265 VAC
(47 to 63Hz),
120/240 VAC nominal
Number of Points
16
8
16
8
8
Isolation
Yes
Yes
N/A
N/A
N/A
4.0 A
8.0 A
2.0 A
2.0 A
2.0 A
10ms maximum
(At nominal voltage
excluding contact bounce)
15 on/15 off
15 on/15 off
30 on/45 off
1 on/1 off
Relay
Relay
Relay
Relay
Relay
N/A
N/A
N/A
N/A
N/A
1
1
4
8
8
IC694TBBx32 or
IC694TBSx32.
Sold Separately.
Terminal Block
(20 screws),
included with module.
Terminal Block
(20 screws),
included with module.
Terminal Block
(20 screws),
included with module.
Terminal Block
(20 screws),
included with module.
300 mA @ 5 VDC
from backplane maximum
6 mA @ 5 VDC;
110 mA @ 24 VDC Relay
7 mA @ 5 VDC;
135 mA @ 24 VDC Relay
80 mA @ 5 VDC;
70 mA @ 24 VDC Relay
80 mA @ 5 VDC;
70 mA @ 24 VDC Relay
Product Name
Output Voltage Range
Load Current
per Point
Response Time (ms)
Output Type
Polarity
Points per Common
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
1.99
Series 90-30
Programmable Controllers
Discrete I/O Modules (Output)
Input modules provide the interface between the PLC and external input devices such as
proximity sensors, push buttons, switches, and BCD thumbwheels. Output modules provide
the interface between the PLC and external output devices such as contactors, interposing
relays, BCD displays and indicator lamps. GE offers a variety of modules that support
different voltage ranges and types, current capacity, isolation and response time to
meet your application needs.
HE693RLY100
HE693RLY110
DC Voltage Output
Module,
AC In/Relay Out
(isolated)
DC Voltage Output Module,
AC In/Relay Out
(fused)
Lifecycle Status
Active
Active
Power Type
Mixed
Mixed
12-120 VAC,
12-30 VDC
12-120 VAC,
12-30 VDC
8
8
Yes
No
8.0 A
8.0 A
11 on/11 off
11 on/11 off
Relay
Relay
N/A
N/A
1
1
Terminal Block
(20 screws),
included with module.
Terminal Block
(20 screws),
included with module.
180 mA @ 5 VDC;
200 mA @ 24 VDC Relay
180 mA @ 5 VDC;
200 mA @ 24 VDC Relay
Product Name
Output Voltage Range
Number of Points
Isolation
Load Current
per Point
Response Time (ms)
Output Type
Polarity
Points per Common
Connector Type
Internal Power Used
1.100
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Analog I/O Modules (Output)
GE offers easy-to-use analog modules for control processes such as flow, temperature
and pressure.
IC693ALG390
IC693ALG391
IC693ALG392
IC693ALG442
Product Name
Analog Output,
Voltage, 2 Channel
Analog Output,
Current/Voltage,
2 Channel
Analog Current/Voltage
Output, 8 Channel
Analog Current/Voltage
Combination 4 Channel
In/2 Channel Out
Lifecycle Status
Active
Active
Active
Active
Analog Output
Analog Output
Analog Output
Analog Input/Output
1500 volts RMS field
to logic side
1500 volts RMS field
to logic side
1500 volts RMS field
to logic side
1500 volts RMS field
to logic side
-10 V to +10 V, 4-20 mA
1-5 V and 0-5 V, 0-20 mA,
4-20 mA
0 V to +10 V, -10 V to +10 V,
0-20 mA, 4-20 mA
0 V to +10 V, -10 V to +10 V,
0-20 mA, 4-20 mA
2
2
8
4 in/2 out
Channel-to-Channel Isolation
N/A
N/A
N/A
N/A
Diagnostics
N/A
N/A
Open Wire
N/A
5 ms all channels
5 ms all channels
8 ms all channels
8 ms all channels In /
4 ms all channels Out
12 bit; 2.5 mV/bit
12 bit; 0-20 mA, 5µA/bit
16 bit; 0.312 mV/bit
(Input)12 bit; 0 V to 10 V,
2.5 mV/bit; -10 V to +10 V,
5 mV/bit; 0-20 mA,
4-20 mA 5µA/bit (Output) 16 bit;
0.312 mV/bit; 4-20 mA 0.5 µA/bit;
0-20 mA 0.625 µA/bit
±5 mV at 25ºC (77ºF)
0-20 mA, ±8 µA at
25ºC (77ºF); 0-20 mA,
4-20 mA ±0.1% at 25ºC (77ºF)
0-20 mA, 4-20 mA ±0.1% at
25ºC (77ºF); 0-10 V,
-10F + 10 V ±0.25 at 25ºC (77ºF)
(Input) 0.25 % at 25ºC (77ºF)
(Output) 0-20 mA, 4-20 mA ±0.1%
at 25ºC (77ºF)
5 mA (2 K ohms)
5 mA (2 K ohms)
5 mA (2 K ohms)
5 mA (2 K ohms); 850 ohms
Module Type
Isolation
Range
Number of Channels
Update Rate
Resolution
Accuracy
Maximum Output Load
Output Load Capacitance
2000 pF
2000 pF, Inductance 1H
2000 pF, Inductance 1H
2000 pF, Inductance 1H
Power Consumption at
Steady State, Maximum
N/A
N/A
N/A
N/A
User Supplied Loop Voltage
N/A
N/A
N/A
N/A
Maximum Load (ohms)
N/A
N/A
N/A
N/A
Maximum Linearity Error
N/A
N/A
N/A
N/A
Common Mode Isolation
N/A
N/A
N/A
N/A
Connector Type
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Internal Power Used
32 mA @ 5 VDC;
120 mA @ 24 VDC Isolated
30 mA @ 5 VDC;
215 mA 24 VDC Isolated
110 mA @ 5 VDC;
315 mA -User Supplied 24 VDC
95 mA @ 5 VDC;
129 mA 24 VDC Isolated
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.101
Series 90-30
Programmable Controllers
Analog I/O Modules (Output)
GE offers easy-to-use analog modules for control processes such as flow, temperature
and pressure.
HE693DAC410
HE693DAC420
Product Name
Isolated Analog Output
Module, Voltage
Isolated Analog Output
Module, Current
Lifecycle Status
Active
Active
Analog Output
Analog Output
N/A
N/A
±10 V
4-20 mA or 0-20 mA
4
4
1500 VAC (RMS),±2000 VDC
1500 VAC (RMS),±2000 VDC
N/A
N/A
N/A
N/A
13 bits plus sign,
1.2 5mV
13 bits plus sign,
2.0 µA (4-20 mA);
2.5 µA (±20 mA)
N/A
N/A
Maximum Output Load
N/A
N/A
Output Load Capacitance
N/A
N/A
0.75 W @ 5 V;
3.6 W @ 24 V
0.75 W @ 5 V;
3.6 W @ 24 V
N/A
2-32 VDC
>/= 2 Kohms
</= 1.1 Kohms @ 24 V loop voltage
Maximum Linearity Error
0.02% full scale
0.02% full scale
Common Mode Isolation
1500 VAC (RMS),±2000 VDC
1500 VAC (RMS), ±2000 VDC
Connector Type
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
500 mA @ 5 VDC;
150 mA @ 24 VDC Relay
150 mA @ 5 VDC;
110 mA @ 24 VDC Relay
Module Type
Isolation
Range
Number of Channels
Channel-to-Channel Isolation
Diagnostics
Update Rate
Resolution
Accuracy
Power Consumption at
Steady State, Maximum
User Supplied Loop Voltage
Maximum Load (ohms)
Internal Power Used
1.102
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Millivolt I/O Modules
The Millivolt Input Modules allow millivolt level signals, such as bridged strain gages
(load cells) to be directly connected to the PLC without external signal processing
­(transducers, transmitters, etc.) All analog and digital processing of the signal is
performed on the module.
HE693ADC409
Product Name
Analog I/O Module, Millivolt Input
Lifecycle Status
Active
Module Type
Millivolt Input
Input Voltage Range
±25 mV, ±50 mV and ±100 mV
Number of Channels
4
Resolution
3 µV, 6µV, 9µV (respectively)
Accuracy
±0.5%
Input Impedance
>20 Mohms
A/D Conversion Type
Integrating
A/D Conversion Time
35 Channels/second
Strain Gages Supported
Maximum Normal Voltage Input
Maximum Voltage Input
Connector Type
Internal Power Used
www.ge-ip.com
Bridged (load cells)
100 mV
±35 V
Terminal Block (20 screws),
included with module.
100 mA @ 5 VDC
GE Intelligent Platforms Control Systems Solutions 1.103
Series 90-30
Programmable Controllers
RTD I/O Modules
The RTD Input Modules provide six RTD inputs that allow the direct connection of 3-wire RTD
temperature sensors without using external signal processing (transducers, transmitters,
etc.). All analog and digital processing of the RTD signal is performed on the module.
HE693RTD600
HE693RTD601
HE693RTD660
HE693RTD665
HE693RTD666
Product Name
RTD Input Module,
Low Resolution
RTD Input Module,
High Resolution
RTD Input Module,
Isolated
RTD Input Module,
Isolated
RTD Input Module,
Isolated
Lifecycle Status
Active
Active
Active
Discontinued
Discontinued
RTD Input
RTD Input
RTD Input
RTD Input
RTD Input
6
6
6
6
6
3-wire, Pt-100E, Pt-100C,
Pt-100Z, Pt-1000, Cu-10, Cu-50,
PT-100, Cu-53, Cu-100, Ni-120,
TD5R, TD5R, Pt-90 (MIL-7990)
3-wire, Pt-100E, Pt-100C,
Pt-100Z, Pt-1000, Cu-10,
Cu-50, PT-100, Cu-53,
Cu-100, Ni-120, TD5R,
TD5R, Pt-90 (MIL-7990)
3 wire, Pt-100E, Pt-100C,
Ni-120, Cu-10, Pt-1000,
TD5R Si
3 wire, Pt-100E, Pt-100C,
Ni-120, Cu-10, Pt-1000,
TD5R Si
3 wire, Pt-100E, Pt-100C,
Ni-120, Cu-10, Pt-1000,
TD5R Si
Channel-to-Channel
Isolation
N/A
N/A
5 VAC
5 VAC
5 VAC
Notch Filter
N/A
N/A
None
50 Hz
60 Hz
0.5°C or 0.5°F
0.125°C , 0.1°C, or 0.1°F
0.05°C, 0.05°F, 0.1°C,
0.1°F, 0.5°C or 0.5°F
0.05°C, 0.05°F, 0.1°C,
0.1°F, 0.5°C or 0.5°F
0.05°C, 0.05°F, 0.1°C,
0.1°F, 0.5°C or 0.5°F
±0.5°C, typical
±0.5°C, typical
±0.3°C
±0.3°C
±0.3°C
Input Impedance
>1000 Megohms
>1000 Megohms
>1000 Megohms
>1000 Megohms
>1000 Megohms
Fault Protection
Zener Diode Clamp
Zener Diode Clamp
Suppression Diode
Suppression Diode
Suppression Diode
Update Time
50 Channels/second
50 Channels/second
50 Channels/second
50 Channels/second
50 Channels/second
18 bit, integrating
18 bit, integrating
18 bit, integrating
18 bit, integrating
18 bit, integrating
330 microamps
330 microamps
330 microamps
330 microamps
330 microamps
Channel-to-Channel
Tracking
0.1°C
0.1°C
0.1°C
0.1°C
0.1°C
Channel-to-Bus Isolation
N/A
N/A
1500 VAC
1500 VAC
1500 VAC
RTD Short
N/A
N/A
Indefinite without damage
Indefinite without damage
Indefinite without damage
Module Type
Number of Channels
RTD Types Supported
Resolution
Accuracy
A/D Conversion Type
Average RTD
Current, Pt-100
Connector Type
Internal Power Used
1.104
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws), Terminal Block (20 screws), Terminal Block (20 screws), Terminal Block (20 screws),
included with module.
included with module.
included with module.
included with module.
70 mA @ 5 VDC
GE Intelligent Platforms Control Systems Solutions
70 mA @ 5 VDC
200 mA @ 5 VDC
200 mA @ 5 VDC
200 mA @ 5 VDC
www.ge-ip.com
Programmable Controllers
Series 90-30
Strain Gage I/O Modules
The Millivolt Input Modules allow millivolt level signals, such as bridged strain gages
(load cells) to be directly connected to the PLC without external signal processing
­(transducers, transmitters, etc.) All analog and digital processing of the signal is
performed on the m
­ odule.
HE693STG883
HE693STG884
Product Name
Analog I/O Module, Strain Gage
Analog I/O Module, Strain Gage
Lifecycle Status
Active
Active
Strain Gage Input
Strain Gage Input
Input Voltage Range
±20 mV, ±25 mV and ±30mV
±25 mV, ±50 mV and ±100mV
Number of Channels
8
8
Resolution
0.6 µV, 0.8 µV, 0.9 µV
(respectively)
0.8 µV, 1.6 µV, 3.2 µV
(respectively)
Accuracy
±0.3%
±0.3 %
>1000 Mohms
>1000 Mohms
A/D Conversion Type
Integrating
Integrating
A/D Conversion Time
35 Channels/second
35 Channels/second
Bridged (load cells)
Bridged (load cells)
100 mV
100 mV
±35 V
±35 V
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws), included with
module.
60 mA @ 5 VDC;
30 mA @ 24 VDC Relay
60 mA @ 5 VDC;
30 mA @ 24 VDC Relay
Module Type
Input Impedance
Strain Gages Supported
Maximum Normal
Voltage Input
Maximum Voltage Input
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.105
Series 90-30
Programmable Controllers
Temperature Control Modules
The Temperature Control Module (TCM), is a high performance control module providing
eight channels of thermocouple input and eight channels of control output in a single Series
90-30 module. Each channel can operate in closed or open loop mode relieving the PLC of
providing the temperature control functions. The module also supports Autotuning.
IC693TCM302
IC693TCM303
Product Name
Temperature Control Module,
(8) T/C, (1) RTD and (8) 24 VDC Output
Temperature Control Module,
Extended Range, 8 T/C,
1RTD and 8 24 VDC Output
Lifecycle Status
Mature
Mature
Thermocouple Input
Thermocouple Input
8 channels (Type J, K or L); J=0-450ºC;
K=0 -600ºC; L=0-450ºC;
1 internal/external compensation
channel, 12-bits or 0.2ºC resolution,
100 ms/ channel update,
±1ºC accuracy with
automatic calibration
8 channels (Type J, K or L);
J=0-600ºC; K=0 -1050ºC; L=0-600ºC;
1 internal/external compensation
channel, 12-bits or 0.2ºC resolution,
100 ms/ channel update,
±1ºC accuracy with
automatic calibration
RTD Input
1 channel with Open/Short Circuit
Detection; Type: Pt-100 (µ=0.00392)
for temperature compensation
1 channel with Open/Short Circuit
Detection; Type: Pt-100 (µ=0.00392)
for temperature compensation
Temperature Range
J=0-600ºC, K=0-1050ºC, L=0-600ºC
J=0-450ºC, K=0-600ºC, L=0-450ºC
Output Voltage Range
18 to 30 volts DC
18 to 30 volts DC
Load Current per point
100 mA maximum sourcing
100 mA maximum sourcing
8 T/C In / 8 DC Out
8 T/C In / 8 DC Out
Open thermocouple and reverse connection
detection capability; Detection and indication of
out-of-tolerance temperature readings
Open thermocouple and reverse connection
detection capability; Detection and indication of
out-of-tolerance temperature readings
Two 20 pin connectors (screw type)
Two 20 pin connectors (screw type)
150 mA @ 5 VDC
150 mA @ 5 VDC
Module Type
Thermocouples
Number of Channels
Diagnostics
Connector Type
Internal Power Used
1.106
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Thermocouple I/O Modules
The Thermocouple Input Modules allow thermocouple temperature sensors to be directly
connected to the PLC with external signal processing (transducers, transmitters, etc.). The
module performs all analog and digital processing of the thermocouple signal. The
enhanced thermocouple input modules add isolation or high-resolution. On these modules,
each channel can be configured for a specific type of sensor wire. An autodetect external
AD592 cold junction compensation feature is also available.
HE693THM166
HE693THM409
HE693THM449
Product Name
Analog I/O Thermocouple
Input Module
Analog I/O Thermocouple
Input Module
Analog I/O Thermocouple
Input Module
Lifecycle Status
Active
Active
Active
Thermocouple Input
Thermocouple Input
Thermocouple Input
J, K, N, T, E, R, S, B, C, X
J, K, N, T, E, R, S
J, K, N, T, E, R, S
Number of Channels
16
4
4
Channel-to-Channel Isolation
N/A
N/A
N/A
Notch Filter
N/A
N/A
N/A
Open Circuit Alarm
Yes
No
Yes
Resolution
0.5°C or 0.5°F
0.5°C or 0.5°F
0.5°C or 0.5°F
Accuracy
±0.5°C, typical (J,K,N,T)
±0.5°C, typical (J,K,N,T)
±0.5°C, typical (J,K,N,T)
A/D Conversion Type
Integrating
Integrating
Integrating
A/D Conversion Time
40 Channels/second
40 Channels/second
40 Channels/second
Open Circuit Detection
Yes
Yes
Yes
Setpoint Alarm
N/A
N/A
N/A
Open Circuit Detection
Open Circuit Detection
Open Circuit Detection
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
80 mA @ 5 VDC;
30 mA @ 24 VDC Relay
80 mA @ 5 VDC;
60 mA @ 24 VDC Relay
80 mA @ 5 VDC;
60 mA @ 24 VDC Relay
Module Type
Range
Diagnostics
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.107
Series 90-30
Programmable Controllers
Thermocouple I/O Modules
The Thermocouple Input Modules allow thermocouple temperature sensors to be directly
connected to the PLC with external signal processing (transducers, transmitters, etc.). The
module performs all analog and digital processing of the thermocouple signal. The
enhanced thermocouple input modules add isolation or high-resolution. On these modules,
each channel can be configured for a specific type of sensor wire. An autodetect external
AD592 cold junction compensation feature is also available.
HE693THM809
HE693THM884
HE693THM888
HE693THM889
Product Name
Analog I/O Thermocouple
Input Module
Analog I/O Thermocouple
Input Module (Enhanced)
Analog I/O Thermocouple
Input Module (Enhanced)
Analog I/O Thermocouple
Input Module
Lifecycle Status
Active
Active
Active
Active
Thermocouple Input
Thermocouple Input
Thermocouple Input
Thermocouple Input
J, K, N, T, E, R, S
J, K, N, T, E, R, S, B, C
J, K, N, T, E, R, S, B, C
J, K, N, T, E, R, S
8
8
8
8
Channel-to-Channel Isolation
N/A
N/A
N/A
N/A
Notch Filter
N/A
None
60 Hz
N/A
Open Circuit Alarm
No
Yes
Yes
Yes
Resolution
0.5°C or 0.5°F
N/A
N/A
0.5°C or 0.5°F
Accuracy
±0.5°C, typical (J,K,N,T)
N/A
N/A
±0.5°C, typical (J,K,N,T)
A/D Conversion Type
Integrating
N/A
N/A
Integrating
A/D Conversion Time
40 Channels/second
N/A
N/A
40 Channels/second
Open Circuit Detection
Yes
Yes
Yes
Yes
Setpoint Alarm
N/A
Yes
Yes
N/A
Module Type
Range
Number of Channels
Diagnostics
Connector Type
Internal Power Used
1.108
Open Circuit Detection
Open Circuit Detection and Alarms Open Circuit Detection and Alarms
Open Circuit Detection
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
80 mA @ 5 VDC;
60 mA @ 24 VDC Relay
100 mA @ 5 VDC;
60 mA @ 24 VDC Relay
100 mA @ 5 VDC;
60 mA @ 24 VDC Relay
80 mA @ 5 VDC;
60 mA @ 24 VDC Relay
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Networks and Distributed I/O Systems
The Series 90-30 features a variety of communications options for distributed control
and/or I/O. Choose from Ethernet EGD, Profibus-DP, Genius, DeviceNet, Interbus-S, Series 90
Protocol (SNP) and RTU modules. These communication modules are easy to install and
quick to configure.
IC693PBM200
IC693PBS201
IC693BEM331
Product Name
Communications Module,
Profibus-DP Module (Master)
Communications Module,
Profibus-DP Module (Slave)
Series 90-30 I/O Bus Module,
Genius Bus Controller
Lifecycle Status
Active
Active
Active
Profibus-DP Master
Profibus-DP Slave
Genius Bus Controller
Profibus DP
Profibus DP
Genius
Entity Type
Master
Slave
Master
Bus Speed
12Mbaud
12Mbaud
153.6Kbaud
Baud Rate Dependent.
Supports all standard
data rates (9.6 kBit/s, 19.2 kBit/s,
93.75 kBit/s, 187.5 kBit/s,
500 kBit/s, 1.5 MBit/s, 3 MBit/s,
6 MBit/s and 12 MBit/s)
Baud Rate Dependent.
Supports all standard
data rates (9.6 kBit/s, 19.2 kBit/s,
93.75 kBit/s, 187.5 kBit/s,
500 kBit/s, 1.5 MBit/s, 3 MBit/s,
6 MBit/s and 12 MBit/s)
7500 feet (2286 meters) at 38.4 Kbaud;
4500 feet (1371 meters) at 76.8 Kbaud;
3500 feet (1066 meters) at 153.6 Kbaud
extended; 2000 feet (609 meters)
at 153.6 Kbaud standard.
Maximum length at each baud
rate also depends on cable type.
Supported
Supported
Supported
Module Type
Protocol Support
Network Distance
Bus Diagnostics
Number of Drops Supported
Message Size
Internal Power Used
www.ge-ip.com
125 Slaves
One
32
244 bytes of input and
244 bytes of output for
each slave. Not to exceed
3584 bytes input and
3584 bytes outputs
total for the system.
244 bytes of input and
244 bytes of output
255 bytes
450 @ 5 VDC
450 @ 5 VDC
300 mA @ 5 VDC
GE Intelligent Platforms Control Systems Solutions 1.109
Series 90-30
Programmable Controllers
Networks and Distributed I/O Systems
The Series 90-30 features a variety of communications options for distributed control
and/or I/O. Choose from Ethernet EGD, Profibus-DP, Genius, DeviceNet, Interbus-S, Series 90
Protocol (SNP) and RTU modules. These communication modules are easy to install and
quick to configure.
IC693DNM200
IC693DNS201
IC693CMM302
Product Name
Series 90-30 Communications
Module, DeviceNet, Master
Series 90-30 Communications
Module, DeviceNet, Slave
Series 90-30 Enhanced Genius
Communications Module
Lifecycle Status
Active
Active
Active
DeviceNet Master
DeviceNet Slave
Genius Peer to Peer
DeviceNet
DeviceNet
N/A
Master
Slave
Peer-to-Peer
Module Type
Protocol Support
Entity Type
Bus Speed
Network Distance
Bus Diagnostics
Number of Drops Supported
500Kbaud
500Kbaud
153.6Kbaud
500Kbaud 100 meters to 125Kbaud
500 meters. Maximum length
at each baud rate also depends
on cable type.
500Kbaud 100 meters to 125Kbaud
500 meters. Maximum length
at each baud rate also depends
on cable type.
7500 feet (2286 meters) at 38.4 Kbaud;
4500 feet (1371 meters) at 76.8 Kbaud;
3500 feet (1066 meters) at 153.6 Kbaud
extended; 2000 feet (609 meters)
at 153.6 Kbaud standard. Maximum
length at each baud rate also
depends on cable type.
Supported
Supported
N/A
64
N/A
N/A
3972 bytes Input and
3972 bytes Output
255 bytes In and
255 bytes Out
N/A
450 @ 5 VDC
450 @ 5 VDC
300 mA @ 5 VDC
Message Size
Internal Power Used
1.110
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Networks and Distributed I/O Systems
The Series 90-30 features a variety of communications options for distributed control
and/or I/O. Choose from Ethernet EGD, Profibus-DP, Genius, DeviceNet, Interbus-S, Series 90
Protocol (SNP) and RTU modules. These communication modules are easy to install and
quick to configure
IC693BEM320
IC693BEM321
Product Name
Series 90-30 Communication,
I/O Link Interface Module (Slave)
Series 90-30 Communication,
I/O Link Interface Module (Master)
Lifecycle Status
Active
Active
I/O Link
I/O Link
N/A
N/A
Slave
Master
Module Type
Protocol Support
Entity Type
Bus Speed
1.5 mHz
1.5 mHz
10 meters (33 feet) RS-485;
200 meters (660 feet)
10 meters (33 feet) RS-485;
200 meters (660 feet)
Bus Diagnostics
N/A
N/A
Number of Drops Supported
N/A
N/A
Message Size
N/A
N/A
205 mA @ 5 VDC
415 mA @ 5 VDC
Network Distance
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.111
Series 90-30
Programmable Controllers
Serial Communications Modules
The Series 90-30 features a variety of communications options for distributed control
and/or I/O. Choose from Ethernet EGD, Profibus-DP, Genius, DeviceNet, Interbus-S, Series 90
Protocol (SNP) and RTU modules. These communication modules are easy to install and
quick to configure.
IC693CMM311
HE693SNP900
HE693RTM705
Product Name
Series 90-30 Communications
Control Module
Communications Module,
SNP Slave Module from
Horner Electric
Communications Module,
Modbus RTU Master from
Horner Electric
Lifecycle Status
Discontinued
Active
Discontinued
Serial Communications
Module Type
SNP Module
Modbus RTU Master
Protocol Support
SNP/SNPX; CCM;
Modbus RTU Slave
SNP Slave
Modbus Master support
Report by Exception
Communication Ports
1 RS-232, 1 RS-485
RS-232, RS-232/485
RS-232, RS-232/485, modem
N/A
No Restrictions
Restricted to IC693CHS391
and IC693CHS397
400 mA @ 5 VDC
250 mA @ 5 VDC
375 mA @ 5 VDC
Backplane Compatibility
Internal Power Used
1.112
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Power Measurement Modules
The Power Transducer Module (PTM) and Power Synchronization and Measurement (PSM) module
measure and calculate critical data for control of electrical power systems and synchronization of
power grids. Both the PTM and PSM connect to user supplied current and potential transformers,
which translate power grid signals to proportionate, low-level signals for measurement and analysis.
The PTM module is not intended to provide a protective relay function or be used for energy billing
purposes. The PSM module provides ANSI protective relay calculations and revenue grade monitoring for a complete genset, paralleling switchgear or infrastructure management solution. Both the
PTM and PSM consist of a processing module that plugs into the PLC backplane, an interface module
for field wiring connections, and cables to interconnect the two modules. The PTM and PSM can be
used with Wye or Delta type three-phase power or with single-phase power systems.
IC693PTM101
Product Name
Power Transducer Module Processing Module interface
board (a panel mounted circuit board). This board interfaces between
the Power Transducer module and the input transformers (current
and potential), 1.0 meter Interface cable that connects the module
to the Interface board.
Lifecycle Status
Mature
Module Type
Power Transducer Modules
Input Voltage Range
Power Measurement
Configurations
Current Input Range
Frequency Range
Output Rating
Number of Outputs
10-120 VAC (nominal)
GridsCircuits
10
0
up to 4
0 to 7.5 Amps RMS (5 A RMS nominal)
35Hz to 70Hz
N/A
0
Data availability
• Data calculation rate: 20ms @ 50Hz, 16.67ms @ 60Hz
• Data latency: 15ms @ 50Hz, 16.67ms @ 60Hz
Data
Measured Data
• RMS voltage of phase A, B, and C (in Volts x 10)
• RMS currents of phase A, B, C, and Neutral (in Amperes x 1000) for each
grid
• DC component of measured RMS voltages (in Volts x 10)
• Frequency of phase A grid 1 (in Hz x 100)
• Phase angle between phase A grid 1 and phase A grid 2
(in degrees x 10)
Power and Energy Data
• Active and reactive power reported per phase and total in Watts, VoltAmperes-Reactive (VAR)
• Active and reactive total energy consumption in Watt-Seconds and
Volt-Amperes-Reactive-Seconds (updated once per second), re-settable
by the user
• Total power factor
• Average real and reactive power consumption (sliding 15 minute
window updated once per second)
Status and Diagnostics
Internal Power Used
www.ge-ip.com
• Module Heartbeat (indicates module health)
• Utility Phase A voltage present
• Phase polarity valid
• Voltage measurements valid
• Current measurements valid
400 mA @ 5 VDC
GE Intelligent Platforms Control Systems Solutions 1.113
Series 90-30
Programmable Controllers
Pneumatic Module
This IC693MDL760 output module provides eleven pneumatic outputs and five 24 VDC sourcing outputs. For each pneumatic output, the module contains an internal 3-way solenoid-actuated valve
and an associated output fitting, which is located on the front panel. When an output is turned ON,
its internal valve connects a user supplied pressure source (100 psi maximum) to the output fitting.
The pressure source is connected to the fitting on the bottom of the module. When the output is
turned OFF, the valve’s output port is vented to atmosphere inside the module. Solenoid power is
supplied from an external 24 VDC source to the “DC Outputs” connector on the front panel.
IC693MDL760
Product Name
Series 90-30 Solenoid Module
Lifecycle Status
Number of Points
Active
(11) Pneumatic Outputs
(5) 24 VDC Outputs
Pneumatic Outputs
11
Supply Pressure
Pressure Drop
External Solenoid Power
100 PSI
25 psi [email protected] 0.25 scfm
21.6-26.4 VDC, 24 VDC nominal
ON Response Time/Off
Response Time
12 ms max. ON
12 ms max. OFF
Solenoid Inrush Current
33 mA/valve @ 24 VDC
Solenoid Holding Current
13 mA/valve @ 24 VDC
Output Fitting
Threaded for 10-32 adapter,
1/16” hose barb provided
Supply Fitting
Threaded for 10-32 adapter,
1/8” hose barb provided
Load Current per Point
0.5 A @ 30 VDC per point,
2.0 A total for all five points
Response Time (ms)
Output Type
Polarity
Transistor
Positive
Internal Power Used
1.114
0.5 on/0.5 off
75 mA from 5 VDC bus
(solenoid LEDs are powered
from external power source)
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Programmable Coprocessor Modules
GE Series 90-30’s feature a wide range of Specialty Modules to meet all of your application
needs. From temperature controls, high-speed counters, I/O processors, coprocessors, to
PID auto-tuning modules, these Specialty Modules are designed to meet the demand for
versatile industrial solutions.
Product Name
Lifecycle Status
Module Type
Programming Languages
Program Storage
Communication Ports
Backplane Compatibility
Internal Power Used
www.ge-ip.com
IC693PCM311
IC693PCM301
HE693ASC900
Series 90-30,
Programmable Coprocessor
Module, 640 KB
(190 KB Basic Prgm)
Series 90-30,
Programmable Coprocessor
Module, 192 KB
(47 KB Basic Prgm)
Horner ASCII
Basic Module
Discontinued
Discontinued
Active
Programmable
Coprocessor Module
Programmable
Coprocessor Module
Co-Processor ASCII
Basic Module
BASIC or C
BASIC or C
BASIC
640K of Battery Backed RAM
192K of Battery Backed RAM or EPROM option
64K EEPROM
(2) One RS-232 and
one RS-232/RS-485
(2) One RS-232 and
one RS-232/RS-485
RS-232, RS-232/485
Restricted to IC693CHS391
and IC693CHS397
Restricted to IC693CHS391
and IC693CHS397
No Restrictions
400 mA @ 5 VDC
425 mA @ 5 VDC
375 mA @ 5 VDC
GE Intelligent Platforms Control Systems Solutions 1.115
Series 90-30
Programmable Controllers
Motion Modules (High Speed Counting)
Motion control integrated into the Series 90-30 fosters high performance point-to-point
applications. GE Motion Control modules can be flexibly applied to a variety of digital,
analog, and stepper motion applications.
IC693APU300
IC693APU305
Product Name
Series 90-30
High Speed Counter
Series 90-30
I/O Processor Module
Lifecycle Status
Active
Active
High Speed Counter
I/O Processor Module
High Frequency - 80 kHz;
Low Frequency - 20 Hz
30 khz (Absolute Encoder)
200 khz (A Quad B Encoder)
Positive Logic
N/A
10 µA per point
10 µA per point
Output Protection
3 Amp Fuse for all points
5 A Fuse for all points
N/A
Counter Operation
Type A - Up or Down-Independent
Pulse-4 counters; Type B - Both
Directions-A QUAD B Encoder Inputs-2
Counters; Type C - Difference Between
2 changing values-A QUAD B Encoder
Inputs -1 Counter
High Frequency Filter - 2.5 µS;
Low Frequency Filter - 12.5 ms
N/A
Selectable On/Off
Output Presets
Each Counter has 2 present points,
On and Off
N/A
N/A
Counters per Timebase
Each counter stores the number
of counts that have occurred
in a specified time. A timebase
value measurement from
1 ms to 65535 ms is configurable.
N/A
Strobe Register
Each counter has one or more
strobe registers that capture the
current accumulator value when a
strobe input transition in the
direction selected during the last
configuration of the module.
(12) 5 VDC or 10 to 30 VDC
(12) 8.0 VDC (non–TTL), 1.5 VDC (TTL)
(4) 10 to 30 VDC @ 500 mA maximum
4.75 to 6 VDC @ 20 mA maximum
Continuous Output Current
(10–30 VDC supply)
1.0 A (each output 1–4)
0.5 A (each output 5°V8)
Terminal Block (20 screws),
included with module.
Terminal Block (20 screws),
included with module.
250 mA @ 5 VDC
360 mA @ 5 VDC
Module Type
Count Rate
Input/Output Type
Off State Leakage Current
Input Filters (Selectable)
Local Fast Inputs
Local Fast Outputs
Connector Type
Internal Power Used
1.116
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Motion Modules (Servo Control)
Motion control integrated into the Series 90-30 fosters high performance point-to-point
applications. GE Motion Control modules can be flexibly applied to a variety of digital,
analog, and stepper motion applications.
IC693DSM324
IC693DSM314
Product Name
Series 90-30 Digital
Servo Module, 4-Axis
Series 90-30 Digital Servo
Module, 4-Axis
(Fiber Optic Interface to Amplifiers)
Lifecycle Status
Active
Active
Servo Module
Servo Module
Beta i Series Digital Servos
Beta i Series Digital and Analog Servos
Fiber Optic, Up to 100 meters
between Amplifiers with total
length of 400 meters.
Digital for Alpha and
Beta Series. ±10V velocity or
torque command for analog
4 Digital
2 Digital and 1 analog or 4 analog
Incremental Master (1Mhz)
Incremental Master (1Mhz)
Parallel or Cascade
Parallel or Cascade
User Memory
15 KBytes
15 KBytes
Analog Inputs
2
4 - In Digital Mode 8 - In Analog Mode
Analog Outputs
2
4 - In Digital Mode 0 - In Analog Mode
Local Fast Inputs
12 (24 V), 8 (5 V)
12 (24 V), 8 (5 V)
4 SSR Outputs (24 VDC, 125 mA)
4 SSR Outputs (24 VDC, 125 mA)
(1) 36 pin (5 VDC) (1) 24 pin (24 VDC)
(4) 36 pin
1360 mA @ 5 VDC
1300 mA @ 5 VDC
Module Type
Drive
Drive Interface
Axes
Encoder Support
Axis Configuration
Local Fast Outputs
Connector Type
Internal Power Used
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.117
Series 90-30
Programmable Controllers
Remote Expansion Modules
The Ethernet distributed I/O interface (Ethernet Interface Unit), is a high performance Ethernet network
interface module. The ENIU enables users to connect Series 90-30 I/O remotely over Ethernet to a
­master controller. The ENIU provides the power of Single Point of Connect. You can connect anywhere
on the I/O network and monitor, configure, and troubleshoot any ENIU. The master controller is also
accessible over the same network to program, troubleshoot and configure. The ENIU features a built-in
Ethernet switch with two 10/100Mbit ports (RJ-45) allowing the user to daisy chain to the next ENIU.
The ENIU automatically senses the cable type, eliminating the need for a crossover cable. The ENIU
­supports one IP address. Redundancy is provided as a standard feature with the ENIU.
IC693NIU004
Product Name
Ethernet Remote I/O Expansion (Slave)
Lifecycle Status
Active
Module Type
Ethernet Remote I/O Interface Module
I/O Discrete Points
2048 Inputs/2048 Outputs maximum
I/O Analog Points
1264 Inputs and 512 Outputs maximum
User Logic Memory
N/A
Network Data Rate
10/100Mbit ports (RJ-45)
Entity Type
Network Distance
Bus Diagnostics
Number of Drops Supported
Slave
Media Dependent
Supported
Network Dependent.
Each Ethernet NIU can also support
up to 7 additional local I/O racks
(IC693CHSxxx)
Internal Power Used
1.118
GE Intelligent Platforms Control Systems Solutions
N/A
www.ge-ip.com
Programmable Controllers
Series 90-30
Portable Program Download Device
(PPDD)
The Portable Program Download Device enables the user
to easily upload and download Series 90-30 configuration
and logic from/to a USB Memory Stick. Portable Program
Download Device (PPDD) will support commercial memory
stick devices using USB connection. The purpose of the
PPDD is to allow users to store and download their logic
applications and configuration to GE Series 90-30 PLCs
without the need of a PC. The PPDD plugs into the 15 pin
RS-485 port on the Series 90-30 CPU base power supply.
The RS-485 port provides the power for the PPDD. Series
90-30 logic and configuration files can be zipped and easily
emailed to remote locations for Series 90-30 downloads.
There are many advantages of the PPDD such as:
• No PC required to backup applications or download applications
• No expensive travel to perform field upgrades, just email the file to the remote location
• Compatible with commercial off the shelf USB Memory Sticks
• The PPDD can be panel mounted, DIN rail mounted or hand held
• Supports diagnostics to ensure that the CPU is compatible with the application
• OEM Password Protection supported
• Simple to operate, LEDs to show activity, error and status. Push button to start download and selector switch for
direction of download, to the PLC or to the memory stick.
• Designed for the industrial environment UL and CE (not Class 1 Div 2 approved)
PPDD features:
• Slide switch for direction of data storage
• Status and Diagnostic LEDs
LEDs Status
LED On Steady
LED Flashing
Fast Flash (500msec on 500msec off)
Slow Flash (1 sec on 1 sec off)
LED Off
www.ge-ip.com
Error (Red)
Status (Green)
On when there isn’t a Memory Stick attached
On after button has been pushed and name in PLC matches and
when download is complete
Flashing when CPU doesn’t match or
Memory Stick doesn’t have the proper file
Slow Flash During Download
Fast Flash when CPU type matches but name in PLC doesn’t match
Flashing if Verify fails
Off during normal conditions with no errors
Off prior to button being pushed for download
GE Intelligent Platforms Control Systems Solutions 1.119
Series 90-30
Programmable Controllers
The Portable Program Download Device is simple to use. The example below
demonstrates the four easy steps of downloading an application and emailing
it to a remote location for application upgrade.
Step 1.
Slide PPDD selector toward USB memory stick. Press
PPDD download button. The PPDD will store/verify
the Series 90-30 application and configuration onto
the USB memory stick.
Step 4.
Place the USB memory stick in the PPDD, slide selector toward
controller. Press PPDD download button. The PPDD will stop
the CPU and download/verify file. The CPU can be placed in
the Run mode via the key switch or cycling power.
Email binary file
Step 2.
Remove the memory stick from the PPDD and connect it
to your PC. Copy the binary file from the memory stick to
your PC and email to remote location.
Step 3.
Remote location takes the binary
file that is in the email and stores
it on a USB memory stick.
Portable Program Download Device
IC690ACC990
1.120
Portable Program Download Device. Supports standard
USB memory devices to store and load Series 90-30
PLC applications without the need of a PC.
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Accessories
IC694TBB032
High Density 32 Point Terminal Block Box Style
Active
IC694TBB132
High Density 32 Point Terminal Block Box Style with Extended Shroud for Large Wiring Bundles
Active
IC694TBS032
High Density 32 Point Terminal Block Spring Style
Active
IC694TBS132
High Density 32 Point Terminal Block Spring Style with Extended Shroud for Large Wiring Bundles
Active
IC690ACC901
Mini-Converter Kit with cable (RS-485/RS-232)
Active
IC690ACC903
RS-485 Port Isolator
Active
IC690CDR002
User Manuals, InfoLink CD-ROM Documentation, single-user license
Active
IC693ACC301
Replacement Battery, CPU & PCM (qty 2)
Active
IC693ACC302
High capacity battery pack. The new Auxiliary Battery Pack (IC693ACC302) will enable Series 90-30 (except CPU374) to go Active
up to 75 months (shelf life of 10 years ) of RAM memory backup w/no power & the CPU374 backup for 15 months
IC693ACC307
I/O Bus Terminator Plug
Active
IC693ACC308
Rack Adaptor Bracket, Series 90-30 10 Slot to 19” (Front Mount)
Active
IC693ACC310
Filler Module, Blank Slot
Active
IC693ACC311
Twenty Point Terminal Blocks (qty 6)
Active
IC200ACC003
EZ Store Device, CPU374 program download without the need of a PC.
Active
IC693ACC319
Spare Plastic Cases Parts Kit (I/O, CPU, PCM)
Active
IC693MLX000
Spare Series 90-30 I/O Modules Label Kit (various quantities)
Active
Terminal Block Quick Connect
Terminal Block Quick Connect (TBQC) for selected I/O modules enables the user to easily connect interposing terminal
blocks. The TBQC consists of an I/O faceplate adapter that includes a 24 pin Fujitsu male connector (the faceplate
replaces the 20 screw terminal connector on front of I/O module, not compatible with the high density 36 screw
terminals), cable and interposing terminal block.
TBQC I/O Module Face Plate Adapter
IC693ACC334
I/O module face plate adapter for 20 screw type I/O modules. Faceplate provides a 24 pin male Fujitsu connector.
Active
TBQC Interposing Terminal Block
IC693ACC329
Interposing terminal block base for IC693MDL645, IC693MDL646, and IC693MDL240. The base can also be used with
any 20 point terminal discrete or analog modules not listed.
Active
IC693ACC330
Interposing terminal block base for IC693MDL740 and IC693MDL742
Discontinued
IC693ACC331
Interposing terminal block base for IC693MDL741
Discontinued
IC693ACC332
Interposing terminal block base for IC693MDL940
Active
IC693ACC333
Interposing terminal block base for IC693MDL340
Active
IC693ACC337
Interposing terminal block base for IC693MDL654/655/752/753
Active
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.121
Series 90-30
Programmable Controllers
TBQC Cables
IC693CBL327
IC693CBL328
IC693CBL329
IC693CBL330
IC693CBL331
IC693CBL332
IC693CBL333
IC693CBL334
Cable, Left Side, One - 24 Pin 90 Degree Connector, 3 Meter. Cable has a connector on only one end and open
on the other. Cable used with TBQC I/O Face Plate Adapter or Fujitsu style I/O modules.
Cable, Right Side, One - 24 Pin 90 Degree Connector, 3 Meter. Cable has a connector on only one end and open
on the other. Cable used with TBQC I/O Face Plate Adapter or Fujitsu style I/O modules.
Cable, Left Side, One - 24 Pin 90 Degree Connector, 1 Meter. from TBQC I/O Face Plate Adapter to TBQC
Interposing Terminal Block.
Cable, Right Side, One - 24 Pin 90 Degree Connector, 1 Meter. from TBQC I/O Face Plate Adapter to TBQC
Interposing Terminal Block.
Cable, Left Side, One - 24 Pin 90 Degree Connector, 2 Meter. from TBQC I/O Face Plate Adapter to TBQC
Interposing Terminal Block.
Cable, Right Side, One - 24 Pin 90 Degree Connector, 2 Meter. from TBQC I/O Face Plate Adapter to TBQC
Interposing Terminal Block.
Cable, Left Side, One - 24 Pin 90 Degree Connector, 0.5 Meter. from TBQC I/O Face Plate Adapter to TBQC
Interposing Terminal Block.
Cable, Right Side, One - 24 Pin 90 Degree Connector, 0.5 Meter. from TBQC I/O Face Plate Adapter to TBQC
Interposing Terminal Block.
Active
Active
Active
Active
Active
Active
Active
Active
External Power Supplies
IC690PWR024
Field Power Supply 24 VDC 5 Amps
Active
IC690PWR124
Field Power Supply 24 VDC 10 Amps
Active
Rack to Rack Expansion Cables
IC693CBL300
Cable, I/O Base Expansion, 1 Meter, Shielded
Active
IC693CBL301
Cable, I/O Base Expansion, 2 Meters, Shielded
Active
IC693CBL302
Cable, I/O Base Expansion, 15 Meters, Shielded with built-in terminator
Active
IC693CBL312
Cable, I/O Base Expansion, 0.15 Meter, Shielded
Active
IC693CBL313
Cable, I/O Base Expansion, 8 Meters, Shielded
Active
IC693CBL314
Cable, I/O Base Expansion, 15 Meters, Shielded with no built-in terminator
Discontinued
IC693ACC307
I/O Bus Terminator Plug
Active
1.122
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Configuration Guidelines
When configuring a Series 90-30 the following guidelines should be considered
1. High density IC693 I/O modules require a terminal block assembly. IC694TBSxxx (spring clamp termination) or IC694TBBxxx (box style termination)
are required.
2. If the CPU is powered down frequently a high capacity battery should be considered. (IC693ACC302)
3. Add up the power consumption to ensure enough power supply capacity.
Examples of Typical Application
Configuration for Controller (Example application requiring (120) 24 VDC inputs and (80) Relay outputs AC power supply)
Power Supply Current Required (mA)
Qty
Part Number
670 mA @ 5 VDC
1
IC693CPU350
CPU with 32K of memory
1
IC693PWR321
120/240 VAC, 125 VDC Power Supply, 3 Amps @ 5 VDC; 0.625 @ 24 VDC relay and 0.833
@ 24 VDC isolated
420 mA @ 5 VDC
1
IC693CHS391
10 Slot CPU Base
1200 mA @ 5 V
4
IC693MDL660
Discrete Input Module, 24 VDC Positive Logic, 32 points (Requires terminal block)
35 mA @ 5 V; 110 mA @ 24 VDC Relay
5
IC693MDL940
Discrete Output Module, Relay 2.0 A per point Form A, 16 points (Terminal block
included).
Total current from power supply required:
Description
4
IC694TBB032
Terminal Block, Box Style
1
BC646MPS001
Logic Developer - PLC Standard - w/Programming Cable
2325 mA @ 5 V; 110 mA @ 24 VDC Relay.
Options to consider
1.4 Amps @ 5 VDC
1
IC693CPU374
CPU with built-in Ethernet 10/100Mbits and Web support
1
IC690PWR024
24 VDC, 5 Amp Output Power and 120/230 VAC Input Power Power Supply
1
IC693ACC302
Long term battery for CPU
1
IC754VSI06STD
QuickPanel View Intermediate 6 inch STN Touch Operator Interface
Configuration for Controller (100) 24 VDC inputs, (50) 24 VDC Outputs with ESCP protection, (20) Relay outputs, (12) 4 to 20 mA Analog Inputs, (12) 4 to 20 mA Analog Outputs
and 24 VDC power supply. Also requires Profibus Master and Ethernet communications.
Power Supply Current Required
1.4 Amps @ 5 VDC
Qty
Part Number
Description
1
IC693CPU374
CPU with built-in Ethernet 10/100 Mbits and Web support
2
IC693PWR331
24 VDC Power Supply, current available 6 Amps @ 5 VDC; 0.625 Amps @ 24 VDC relay;
0.833 @ 24 VDC isolated
420 mA @ 5 VDC
1
IC693CHS391
10 Slot CPU Base
1200 mA @ 5 VDC
4
IC693MDL660
Discrete Input Module, 24 VDC Positive Logic, 32 points (Requires terminal block)
600 mA @ 5 VDC
2
IC693MDL754
Discrete Output Module, 24 VDC Output with ESCP, 32 points (Requires terminal block)
35 mA @ 5 VDC; 110 mA @ 24 VDC Relay
2
IC693MDL940
Discrete Output Module, Relay 2.0 A per point Form A, 16 points (Terminal block included).
120 mA @ 5 VDC; 65 mA-User Supplied 24 VDC
1
IC693ALG223
Analog Input, 16 channels, current. (Terminal block included).
220 mA @ 5 VDC; 630 mA-User Supplied 24 VDC
2
IC693ALG392
Analog Output module, supports voltage and current, 8 channels (Terminal block
included).
450 mA @ 5 VDC
1
IC693PBM200
Profibus Master module, supports V0
150 mA @ 5VDC
1
IC693CHS392
10 slot I/O expansion rack
1
IC693CBL312
Rack Expansion Cable, 0.15 meters
1
IC693ACC307
I/O Bus Terminator Plug
6
IC694TBB032
Terminal Block, Box Style
1
BC646MPS001
Logic Developer - PLC Standard - w/Programming Cable
In the above configuration, all of the modules cannot go into one base. Therefore the I/O modules are divided into two bases.
Options to consider
www.ge-ip.com
1
IC200ACC003
EZ Store Device, CPU374 program download without the need of a PC.
1
IC690PWR024
24 VDC, 5 Amp Output Power and 120/230 VAC Input Power Power Supply
1
IC693ACC302
Long term battery for CPU
1
IC754VSI06STD
QuickPanel View Intermediate 6 inch STN Touch Operator Interface
GE Intelligent Platforms Control Systems Solutions 1.123
Series 90-30
Programmable Controllers
α and βi Series Servo Amplifiers
All Digital Servo Systems Offer High Performance and Reliability. FANUC HVis
and βi Series Servo Drives, based on over five million axes installed worldwide,
offer superior reliability and performance for unprecedented mean time
between failure. The HVis and βi Series Servos are available in a wide range
of ratings for use with the PACMotion motion controller.
High-Performance
Serial Encoders
Standard serial encoders built into the
motors provide exceptional feedback
­resolution of 64K or 128K counts per
revolution for is Series motors and
one million counts per revolution for
HVis Series motors. Serial encoders
support higher resolutions at high
motor velocities than standard
quadrature encoders and are more
immune to noise. An optional battery
connection provides absolute position
feedback, eliminating the need
to home the system after a power
shutdown.
Series
Motor Series
Controllers
Command
Interface
In-lb
Nm
Reduced Tuning and Setup
aHVi
aHVi, aHVis
PMM335
Fiber Optic
195-664
22-75
Separate PSM
There is no need for potentiometer
tuning or personality modules; little
tuning is required for properly sized
drives. All drive parameters are stored
in the controller in a standard motor
database. Configuration settings are
not stored in the drive, making it possible to replace drives with little set-up
time. Stored drive and machine
parameters are quickly transferred to
repeat production machines.
ßi
ßis
PMM335
Fiber Optic
3.5-177
0.4-20
Built-in
ßHVi
ßHVis
PMM335
Fiber Optic
17.7-177
20-Feb
Built-in
All-Digital System
All control loops—current, velocity,
and position—are closed in the
GE PACMotion controller. High-speed
microprocessors and/or digital signal
processors (DSPs) in the controller
provide loop update times of 250 µs.
The high response servo system can
compensate for machine design
limitations, yielding faster
acceleration/deceleration rates
and better responses to load changes.
1.124
All-Digital Servo
Command Signals
The PMM335 PACMotion Controller and
βi or αi Series amplifiers use a high
speed fiber optic command interface.
This digital interface improves efficiency by varying the on-time of the
transistor switches that control motor
­voltage and current. With its superior
noise immunity, both of these FANUC
digital command interfaces allows for
an increased signal to noise ratio for
improved accuracy and performance.
GE Intelligent Platforms Control Systems Solutions
Continuous
Torque Range
Power Supply
Agency Approvals
UL, IEC rating and CE mark compliant
INFO
For application, installation, and tuning
information, consult the Services website at
www.ge-ip.com.
www.ge-ip.com
Programmable Controllers
Series 90-30
VersaMotion
VersaMotion is a family of servo
motors and amplifiers that can be
easily connected to the Series 90-30
DSM314. The VersaMotion amplifier
supports high speed pulse and direction commands from the controllers.
The VersaMotion servo drive is simple
to use and maintain with the added
diagnostics and removable terminal
strips. Amplifier setup can be accomplished using the VersaMotion software
included with Proficy Machine Edition
or using the convenient front panel
­keypad.
Key Features:
• Versatile analog or pulse command
interface
• Position/Speed/Torque modes
• Dual control modes
• Internal single-axis position control
• Electronic gearing
• External JOG function
• Speed/Torque limit operation
• Built-in keypad/display for setup and
diagnostics
• Motor settling time below 1 ms
• Low speed stability and
performance: less than 0.5% error
at 1 RPM
Built-in Functions:
• Point-to-Point single axis position
control
• Simple stand-alone positioning
f­ unction with 8 internal stored
­position settings
• Configuration Parameter Editor
(clear, read, write functions) and
­initial configuration wizard
• Calculation tools to determine
­proper conversion from encoder
counts to desired user programming
units
• Move to Home function
• Position Teaching capability
• Incremental encoder feedback
(2500 ppr)
• Three channel digital oscilloscope to
display and record drive status
on-line
• User-definable Acceleration/
Deceleration with jerk limiting
(s-curve)
• Alarm history and status monitor
diagnostic screens
• 10msec acceleration time from running without load -/+ 3000 RPM
• Feed step control function
• High speed inertia corrections
(16 levels of system stiffness and
­responsiveness)
• Modbus Slave serial port (RS-485/
RS-422) for reading and writing
parameters from Machine Edition
www.ge-ip.com
Machine Edition VersaMotion
Set-up Features:
• Digital I/O set-up and monitoring
GE Intelligent Platforms Control Systems Solutions 1.125
Series 90-30
Programmable Controllers
Servo Amplifier Part Number Sequence
IC800VMA
04
2
Input Voltage
2– 220 VAC Single Phase
Rated Power
01– 100 Watts
02– 200 Watts
04– 400 Watts
07– 750 Watts
10– 1000 Watts
20– 2000 Watts
30–­3000 Watts
Example: IC800VMA042 is a 400 watt 220 VAC servo amplifier
Amplifiers Technical Data
Permissible Frequency Fluctuation
50 / 60 Hz ±5%
Resolution/Quadrature Feedback Counts
2500 ppr /10000 cpr
Control Modes
Position/Velocity/Torque
Dynamic Brake
Built-in
Position Control Mode:
Maximum Input Pulse Frequency
500KPPS (Line Driver) / Maximum 200KPPS (Open Collector)
Pulse Type
Pulse/Direction; CW/CCW; A/B Phase
Command Source
External pulse train/ Internal parameters
Torque Limit Operation
Yes
Feed Forward Compensation
Yes
Analog Commands: Voltage Range
0 to ±10 VDC
Torque and Velocity Control Mode: Command Source
External analog signal / Internal parameters
Speed Control Range
3.513888889
Speed Control Frequency Response
Maximum 450 Hz
Torque Control Mode Permissible Time for Overload
8 seconds under 200% rated output
Communications Interface
RS-232 / RS-485 /RS-422
Environmental Altitude
Altitude 1000 meters above sea level or lower
Environmental Operating Temperature
0 to 55°C (Forced cooling for operation above 55°C)
Environmental Storage Temperature
-20°C to 65°C
Environmental Humidity
0 to 90% (Non condensing)
Vibration
<20 Hz: 9.8 m/sec/sec (1G); 20 to 50 Hz: 5.88 m/sec/sec (0.6 G)
Standards
IEC/EN 61800-5-1, UL 508C, TUV, C-tick
1.126
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Amplifiers
The VersaMotion family of servo amplifiers offers a cost effective solution for a broad range
of motion applications. These versatile amplifiers support simple stand-alone positioning
capability using up to 8 stored motion profiles or can be connected to any motion controller
using an analog or pulse command interface. A built-in touchpad and display provides
convenient access to configuration parameters and system information. The serial interface
supports multi-drop system configurations and Modbus communication protocol.
IC800VMA012
IC800VMA022
IC800VMA042
IC800VMA072
Product Name
VersaMotion Amplifier
VersaMotion Amplifier
VersaMotion Amplifier
VersaMotion Amplifier
Lifecycle Status
Active
Active
Active
Active
Rated Output Power
100W
200W
400W
750W
Voltage/Frequency
Three-phase or Single-phase
220 VAC 50/60 Hz
Three-phase or Single-phase
220 VAC 50/60 Hz
Three-phase or Single-phase
220 VAC 50/60 Hz
Three-phase or Single-phase
220 VAC 50/60 Hz
Permissible Voltage
Fluctuation
Three-phase: 170 ~ 255 VAC
Single-phase: 200 ~ 255 VAC
Three-phase: 170 ~ 255 VAC
Single-phase: 200 ~ 255 VAC
Three-phase: 170 ~ 255 VAC
Single-phase: 200 ~ 255 VAC
Three-phase: 170 ~ 255 VAC
Single-phase: 200 ~ 255 VAC
Convection
Convection
Convection
Fan Cooling
Gear Ratio = N/M where N
1~32767, M: 1:32767
(1/50<N/M<200)
Gear Ratio = N/M where N:
1~32767, M: 1:32767
(1/50<N/M<200)
Gear Ratio = N/M where N:
1~32767, M: 1:32767
(1/50<N/M<200)
Gear Ratio = N/M where N:
1~32767, M: 1:32767
(1/50<N/M<200)
Cooling System
Electronic Gear Ratio
IC800VMA102
IC800VMA202
IC800VMA302
Product Name
VersaMotion Amplifier
VersaMotion Amplifier
VersaMotion Amplifier
Lifecycle Status
Active
Active
Active
Rated Output Power
1KW
2KW
3KW
Voltage/Frequency
Three-phase or Single-phase
220 VAC 50/60 Hz
Three-phase 220 VAC
50/60 Hz
Three-phase 220 VAC
50/60 Hz
Permissible Voltage
Fluctuation
Three-phase: 170 ~ 255 VAC
Single-phase: 200 ~ 255 VAC
Three-phase: 170 ~ 255 VAC
Three-phase: 170 ~ 255 VAC
Fan Cooling
Fan Cooling
Fan Cooling
Gear Ratio = N/M where N
1~32767, M: 1:32767
(1/50<N/M<200)
Gear Ratio = N/M where N:
1~32767, M: 1:32767
(1/50<N/M<200)
Electronic gear N/M multiple N:
1~32767, M: 1:32767
(1/50<N/M<200)
Cooling System
Electronic Gear Ratio
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.127
Series 90-30
Programmable Controllers
Servo Motor Part Number Sequence
IC800VMM
30
M
B
K
S
E25
Feedback
E25– 2500 ppr incremental encoder
Rated Power
01– 100 Watts
02– 200 Watts
04– 400 Watts
07– 750 Watts
10– 1000 Watts
20– 2000 Watts
30–­3000 Watts
Shaft Seal
S– With seal
Key
K– With shaft key
Brake
N– No brake
B– With brake (except 100 Watt Motor)
Inertia
L– Low Inertia
M– Medium Inertia (1Kw, 2Kw and 3Kw models only)
Example: IC800VMM30MBKSE25 is a 3000 watt medium Inertia motor with 2500 ppr encoder, brake, keyway and shaft seal.
Motors Technical Data
Insulation Class
Class B
Insulation Resistance
>100M ohm, 500 VDC
Insulation Strength
1500 VAC, 50Hz, 60 seconds
Vibration Grade (um)
15
Brake Power (VDC)
24
Operating Temperature (C)
0°~40°
Storage Temperature (C)
-10°~80°
Humidity
20~90%RH (non condensing)
Vibration
2.5G
IP Rating
IP65 (except shaft and connector)
1.128
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Motors
The VersaMotion family of servo motors offers high servo performance in a compact
­package. The motors range from 100 W to 3 kW with continuous torque ratings from
0.3 Nm to 14.3 Nm. All motors have metric mounting configurations and include a shaft
key and oil seal. For vertical axes or applications that need to hold position during power
loss motors with 24 VDC holding brakes are available. Motors are matched with the
VersaMotion amplifiers.
IC800VMM01L
IC800VMM02L
IC800VMM04L
IC800VMM07L
Product Name
VersaMotion
100 Watt
VersaMotion
200 Watt
VersaMotion
400 Watt
VersaMotion
750 Watt
Lifecycle Status
Active
Active
Active
Active
Rated Output (kW)
0.1
0.2
0.4
0.75
Rated Torque (Nm)
0.32
0.64
1.27
2.39
Maximum Torque (Nm)
0.96
1.92
3.82
7.16
Rated Speed (RPM)
3000
3000
3000
3000
Maximum Speed (RPM)
5000
5000
5000
5000
Rated Current (Amps)
0.9
1.55
2.6
5.1
Maximum Current (Amps)
2.7
4.65
7.8
15.3
Rotor Moment of Inertia
(Kg.m2 x 10-4)
0.037
0.177
0.277
1.13
Mechanical Time
Constant (msec)
0.75
0.8
0.53
0.63
Torque Constant KT (Nm)
0.36
0.41
0.49
0.47
Voltage Constant KE (mV/rmp)
13.6
16
17.4
17.2
Armature Resistance
(Ohm)
9.3
2.79
1.55
0.42
Armature Inductance
(mH)
24
10.84
6.84
3.53
Electrical Time Constant
(msec)
2.58
3.89
4.43
8.37
Maximum Radial
Shaft Load (Newton)
78.4
196
196
245
Maximum Thrust
Shaft Load (Newton)
39.2
68
68
98
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.129
Series 90-30
Programmable Controllers
Motors
The VersaMotion family of servo motors offers high servo performance in a compact
­package. The motors range from 100 W to 3 kW with continuous torque ratings from
0.3 Nm to 14.3 Nm. All motors have metric mounting configurations and include a shaft
key and oil seal. For vertical axes or applications that need to hold position during power
loss motors with 24 VDC holding brakes are available. Motors are matched with the
VersaMotion amplifiers.
IC800VMM10L
IC800VMM10M
IC800VMM20L
IC800VMM20M
IC800VMM30M
Product Name
VersaMotion
1000 Watt
VersaMotion
1000 Watt
VersaMotion
2000 Watt
VersaMotion
2000 Watt
VersaMotion
3000 Watt
Lifecycle Status
Active
Active
Active
Active
Active
Rated Output (kW)
1
1
2
2
3
Rated Torque (Nm)
3.18
4.77
6.37
9.55
14.32
Maximum Torque (Nm)
9.54
14.32
19.11
28.66
42.96
Rated Speed (RPM)
3000
2000
3000
2000
2000
Maximum Speed (RPM)
5000
3000
5000
3000
3000
Rated Current (Amps)
7.3
5.6
11.3
11
16.1
Maximum Current (Amps)
21.9
24.9
33.9
33
48.3
Rotor Moment of Inertia
(Kg.m2 x 10-4)
2.65
9.14
4.45
15.88
55
Mechanical Time Constant
(msec)
0.74
1.64
0.66
1.05
1.06
Torque Constant KT (Nm/A)
0.44
0.85
0.53
0.87
0.89
Voltage Constant KE (mV/rpm)
16.8
31.9
19.2
31.8
32
Armature Resistance
(Ohm)
0.2
0.465
0.14
0.174
0.052
Armature Inductance
(mH)
2
5.99
1.53
2.76
1.38
10.26
12.88
10.63
15.86
26.39
Maximum Radial
Shaft Load (Newton)
490
490
490
490
1470
Maximum Thrust
Shaft Load (Newton)
98
98
98
98
490
IC800VMA102
IC800VMA102
IC800VMA202
IC800VMA202
IC800VMA302
Electrical Time Constant
(msec)
Amplifier Model
1.130
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
VersaMotion Accessories
Accessories
IC800VMACONCN1
CN1 I/O Connector
Active
IC800VMACONCN2
CN2 Encoder Connector
Active
IC800VMACONCN3
CN3 Communication Connector
Active
IC800VMACONACP
AC Power Connector (100W to 1kW models only)
Active
IC800VMACONMTRP
Motor Power Connector (100W to 1kW models only)
Active
IC800VMADBR001
External Braking Resistor Connector (100W to 1kW models only)
Active
IC800VMMCONP001
Motor Power Connector for 100 Watt to 750 Watt motors without brake
Active
IC800VMMCONP002
Motor Power Connector for 100 Watt to 750 Watt motors with brake
Active
IC800VMMCONP003
Motor Power Connector for 1000 Watt or 2000 Watt motors with or without brake
Active
IC800VMMCONP004
Motor Power Connector for 3000 Watt motors with or without brake
Active
IC800VMMCONE001
Encoder Connector for 100 Watt to 750 Watt motors
Active
IC800VMMCONE002
Encoder Connector for 1000 Watt and larger motors
Active
Motor Connectors
Motor Power Cables
IC800VMCP030
Power Cable for 100 Watt to 750 Watt servo motor without brake, 3 m (9.8 feet)
Active
IC800VMCP050
Power Cable for 100 Watt to 750 Watt servo motor without brake, 5 m (16.4 feet)
Active
IC800VMCP100
Power Cable for 100 Watt to 750 Watt servo motor without brake, 10 m (32.8 feet)
Active
IC800VMCP200
Power Cable for 100 Watt to 750 Watt servo motor without brake, 20 m (65.7 feet)
Active
IC800VMCP1030
Power Cable for 1000 Watt servo motor without brake, 3 m (9.8 feet)
Active
IC800VMCP1050
Power Cable for 1000 Watt servo motor without brake, 5 m (16.4 feet)
Active
IC800VMCP1100
Power Cable for 1000 Watt servo motor without brake, 10 m (32.8 feet)
Active
IC800VMCP1200
Power Cable for 1000 Watt servo motor without brake, 20 m (65.7 feet)
Active
IC800VMCP2030
Power Cable for 2000 Watt servo motor without brake, 3 m (9.8 feet)
Active
IC800VMCP2050
Power Cable for 2000 Watt servo motor without brake, 5 m (16.4 feet)
Active
IC800VMCP2100
Power Cable for 2000 Watt servo motor without brake, 10 m (32.8 feet)
Active
IC800VMCP2200
Power Cable for 2000 Watt servo motor without brake, 20 m (65.7 feet)
Active
IC800VMCP3030
Power Cable for 3000 Watt servo motor without brake, 3 m (9.8 feet)
Active
IC800VMCP3050
Power Cable for 3000 Watt servo motor without brake, 5 m (16.4 feet)
Active
IC800VMCP3100
Power Cable for 3000 Watt servo motor without brake, 10 m (32.8 feet)
Active
IC800VMCP3200
Power Cable for 3000 Watt servo motor without brake, 20 m (65.7 feet)
Active
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.131
Series 90-30
Programmable Controllers
Brake and Motor Power Cables
IC800VMCB030
Brake and Motor Power Cable for 200 Watt to 750 Watt servo motor with brake, 3 m (9.8 feet)
Active
IC800VMCB050
Brake and Motor Power Cable for 200 Watt to 750 Watt servo motor with brake, 5 m (16.4 feet)
Active
IC800VMCB100
Brake and Motor Power Cable for 200 Watt to 750 Watt servo motor with brake, 10 m (32.8 feet)
Active
IC800VMCB200
Brake and Motor Power Cable for 200 Watt to 750 Watt servo motor with brake, 20 m (65.7 feet)
Active
IC800VMCB1030
Brake and Motor Power Cable for 1000 Watt servo motor with brake, 3 m (9.8 feet)
Active
IC800VMCB1050
Brake and Motor Power Cable for 1000 Watt servo motor with brake, 5 m (16.4 feet)
Active
IC800VMCB1100
Brake and Motor Power Cable for 1000 Watt servo motor with brake, 10 m (32.8 feet)
Active
IC800VMCB1200
Brake and Motor Power Cable for 1000 Watt servo motor with brake, 20 m (65.7 feet)
Active
IC800VMCB2030
Brake and Motor Power Cable for 2000 Watt servo motor with brake, 3 m (9.8 feet)
Active
IC800VMCB2050
Brake and Motor Power Cable for 2000 Watt servo motor with brake, 5 m (16.4 feet)
Active
IC800VMCB2100
Brake and Motor Power Cable for 2000 Watt servo motor with brake, 10 m (32.8 feet)
Active
IC800VMCB2200
Brake and Motor Power Cable for 2000 Watt servo motor with brake, 20 m (65.7 feet)
Active
IC800VMCB3030
Brake and Motor Power Cable for 3000 Watt servo motor with brake, 3 m (9.8 feet)
Active
IC800VMCB3050
Brake and Motor Power Cable for 3000 Watt servo motor with brake, 5 m (16.4 feet)
Active
IC800VMCB3100
Brake and Motor Power Cable for 3000 Watt servo motor with brake, 10 m (32.8 feet)
Active
IC800VMCB3200
Brake and Motor Power Cable for 3000 Watt servo motor with brake, 20 m (65.7 feet)
Active
IC800VMCE030
Encoder Cable for 100 to 750 Watt, 3 m (9.8 feet)
Active
IC800VMCE050
Encoder Cable for 100 to 750 Watt, 5 m (16.4 feet)
Active
IC800VMCE100
Encoder Cable for 100 to 750 Watt, 10 m (32.8 feet)
Active
IC800VMCE200
Encoder Cable for 100 to 750 Watt, 20 m (65.7 feet)
Active
IC800VMCE1030
Encoder Cable for 1000 Watt and greater, 3 m (9.8 feet)
Active
IC800VMCE1050
Encoder Cable for 1000 watt and greater, 5 m (16.4 feet)
Active
IC800VMCE1100
Encoder Cable for 1000 watt and greater, 10 m (32.8 feet)
Active
IC800VMCE1200
Encoder Cable for 1000 watt and greater, 20 m (65.7 feet)
Active
I/O Terminal Block Breakout Board and 0.5 m (1.6 feet) Cable
Active
Encoder Cables
I/O Terminal Block
IC800VMTBC005
External Braking Resistors
IC800VMBR040
40 Ohm, 400 Watt External Braking (Regeneration) Resistor
Active
IC800VMBR020
20 Ohm, 1000 Watt External Braking (Regeneration) Resistor
Active
Communications and I/O Interface Cables
IC800VMCS030
Communications Cable from servo amplifier to PC, 3 m (9.8 feet)
Active
IC800VMCI010
Flying lead I/O interface cable, 1 meter
Active
IC800VMCI030
Flying lead I/O interface cable, 3 meter
Active
Software Configuration Tool
IC646MPM101
Proficy Logic Developer - PLC Nano/Micro and VersaMotion, Programming Cable (No Upgrades included)
Active
BC646MPM101
Proficy Logic Developer - PLC Nano/Micro and VersaMotion, Programming Cable (Includes 15 months of upgrades)
Discontinued
1.132
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Series 90-30
Examples of Typical Application using a Series 90-30
Application: 1000 Watt Low Inertia Motor with Brake. Configuration for Controller (100) 24 VDC inputs, (50) 24 VDC Outputs with ESCP protection, (20) Relay outputs, (12) 4 to 20 mA
Analog Inputs, (12) 4 to 20 mA Analog Outputs and 24 VDC power supply. Also requires Profibus Master and Ethernet communications.
Qty
Part Number
Description
Controller, I/O and Display
1
IC693CPU374
CPU with built-in Ethernet 10/100Mbits and Web support
2
IC693PWR331
24 VDC Power Supply, current available 6 Amps @ 5 VDC; 0.625 Amps @ 24 VDC relay; 0.833 @ 24 VDC isolated
1
IC693CHS391
10 Slot CPU Base
1
IC693DSM314
Servo Motion Module, 2 digital and 1 analog axis supported
1
IC693ACC336
DSM Analog Servo Interface Terminal Board
1
IC693CBL324
DSM Analog TB Interface Cable, 1 m (3.28 feet)
1
IC800VMCI010
VersaMotion Flying Lead I/O Interface Cable, 1 m (3.28 feet)
4
IC693MDL660
Discrete Input Module, 24 VDC Positive Logic, 32 points (Requires terminal block)
2
IC693MDL754
Discrete Output Module, 24 VDC Output with ESCP, 32 points (Requires terminal block)
2
IC693MDL940
Discrete Output Module, Relay 2.0 A per point Form A, 16 points (Terminal block included)
1
IC693ALG223
Analog Input Module, 16 channels, current. (Terminal block included)
2
IC693ALG392
Analog Output Module, supports voltage and current, 8 channels (Terminal block included)
1
IC693PBM200
Profibus Master Module, supports V0
1
IC693CHS392
10 slot I/O Expansion Rack
1
IC693CBL312
Rack Expansion Cable, 0.15 meter
1
IC693ACC307
I/O Bus Terminator Plug
6
IC694TBB032
Terminal Block, Box Style
1
BC646MPS001
Logic Developer - PLC Standard - w/Programming Cable
Servo and Motor
1
IC800VMM10LBKSE25
VersaMotion 1000 Watt Low Inertia Servo Motor with Brake. Motor has keyway and oil seal
1
IC800VMA102
Servo Amplifier, 1000 Watts, 220 VAC
1
IC800VMCB1030
Brake and Power Cable for 1000 Watt Servo Motor with Brake, 3 m (9.8 feet)
1
IC800VMCE1030
Encoder Cable for 1000 Watt and greater, 3 m (9.8 feet)
1
IC800VMTBC005
I/O Terminal Block and Cable (0.5 meter)
1
IC800VMCS030
Communications Cable from Servo Driver to PC, 3 m (9.8 feet)
Programming Software for Control, Display and Motion
1
BC646MPS001
www.ge-ip.com
Machine Edition Standard Development Suite with Proficy GlobalCare Complete. Includes VersaMotion configuration tool, View
Development for QuickPanel and PLC Standard with programming cable. Proficy GlobalCare with 15 months of free upgrades which
is renewable on an annual basis.
GE Intelligent Platforms Control Systems Solutions 1.133
VersaMax Nano and Micro
Programmable Controllers
VersaMax Nano and Micro Controllers
Don’t let size fool you. Although they
are easy on valuable panel space, the
VersaMax Nano and Micro PLCs are big
on features. For high-volume applications
where cost and fast processor speeds
are an issue, the VersaMax Nano is the
PLC of choice. For additional functionality, the modular VersaMax Micro offers
the features and the flexibility to match
application needs in such industries as
food processing, chemicals, packaging,
water and wastewater, construction
equipment and plastics.
For tight spaces, the VersaMax Nano
PLC is the perfect solution. Thanks to its
all-in-one construction, installation is a
breeze. All you have to do is snap it onto
a DIN rail or screw it into a panel. With
the VersaMax Nano, you save on initial
as well as life cycle costs.
The small-footprint VersaMax Micro PLC
offers the flexibility of modular design
and a variety of built-in features, including
up to 64 I/O points (expandable to 170
I/O points), fast cycle times, a robust
instruction set and extensive memory
that multiplies your programming options.
Proficy Machine Edition
Proficy Machine Edition is an
advanced software environment for
the development and maintenance
of machine level automation.
Visualization, motion control, and
­execution logic are developed with
a single programmer.
Publication Reference Chart
GFK-1645
VersaMax Micro PLCs and Nano
PLCs User’s Manual
IC690CDU002 InfoLink for PLC CD-ROM
Accessories, pages 1.162-1.163
Configuration Guidelines, pages 1.164-1.165
Nano PLCs, page 1.136
Micro PLCs,
pages 1.137-1.145
Expansion Units,
pages 1.146-1.156
DataPanels Operator
Interfaces, page 1.157
Communications Options,
pages 1.158-1.159
Portable Program
Download Device (PPDD),
pages 1.160-1.161
VersaMotion Servo Motors
and Amplifiers,
pages 1.166-1.174
VersaMax Nano and Micro Selection Guide
Features
Nano 10
Micro 14
Micro 23
Micro 28
Micro 20
Micro 40
Micro 64
Built-in Discrete I/O
6 in/ 4out
8 in/ 6 out
13 in/10 out
16 in/12 out
12 in/8 out
24 in/16 out
40 in/24 out
Built-in Analog I/O
1 on some models
none
2 in/ 1 out
none
none
none
none
I/O Expansion Units
none
Up to 4 units
Up to 4 units
Up to 4 units
Up to 4 units
Up to 4 units
Up to 4 units
24K
Logic Memory (Words)
2K
9K
9K
9K
24K
24K
Data Storage (Words)
256
256
2K
2K
32K
32K
32K
Scan Time (msec/K)
1.3 msec
1.1 msec
1.1 msec
1.1 msec
1.1 msec
1.1 msec
1.1 msec
Battery Backed RAM
Super Cap only
Super Cap only
Yes and Super Cap
Yes and Super Cap
Yes and Super Cap
Yes and Super Cap
Yes and Super Cap
none
none
Yes, Included
Yes, Included
Yes, Included
Yes, Included
Yes, Included
1 RS-232
1 RS-232
1 RS-232 and 1
RS-485
1 RS-232 and 1
RS-485
1 RS-232 and second
port optional RS-232,
RS-485, USB or
Ethernet
1 RS-232 and second
port optional RS-232,
RS-485, USB or
Ethernet
1 RS-232 and second
port optional RS-232,
RS-485, USB or
Ethernet
Ethernet Option
Yes, VersaMax SE
Yes, VersaMax SE
Yes, VersaMax SE
Yes, VersaMax SE
Yes on second port
Yes on second port
Yes on second port
High Speed Counter
Up to 4 at 10Khz
(16 bit)
Up to 4 at 10Khz
(16 bit)
Up to 4 at 10Khz
(16 bit)
Up to 4 at 10Khz
(16 bit)
Up to 4 at 100Khz
(32 bit)
Up to 4 at 100Khz
(32 bit)
Up to 4 at 100Khz
(32 bit)
Pulse Train/PWM
Up to 4 at 5Khz
(16 bit)
Up to 4 at 5Khz
(16 bit)
Up to 4 at 5Khz
(16 bit)
Up to 4 at 5Khz
(16 bit)
Up to 4 at 65Khz
(32 bit)
Up to 4 at 65Khz
(32 bit)
Up to 4 at 65Khz
(32 bit)
N/A
N/A
N/A
N/A
No
Yes
Yes
Yes
No
No
No
No
Real Time Clock
Ports Available
Motion Commands
Write Register Values to
Internal Flash
On Line Program Support
1.134
GE Intelligent Platforms Control Systems Solutions
Find Home,
Find Home,
Find Home,
Go Home, Jog, Ramp, Go Home, Jog, Ramp, Go Home, Jog, Ramp,
Blended Move
Blended Move
Blended Move
(4 Consecutive Moves) (4 Consecutive Moves) (4 Consecutive Moves)
Yes
Yes
Yes
Yes with Firmware 3.9 Yes with Firmware 3.9 Yes with Firmware 3.9
& Hardware revision B
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Powerful Instruction Set
Bit Operation Functions
Data Move Functions
Relation Functions
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Logic AND, Logic OR
Exclusive OR, Logical Invert
Shift Right/Left
Rotate Right/Left
Bit Test/Set/Clear
Masked Compare
Bit Position
Bit Sequencer
Control Functions
•
•
•
•
•
•
•
•
Move
Block Move
Block Clear
Shift Register
Communications Request
• Motion Moves
• High Speed Counter
• Serial Read/Write
• Modbus Master
Relay Functions
• Contacts, Coils
• Fault and No Fault Contacts
• Alarm Contacts
Conversion Functions
Do I/O
Call
End
Subroutines
Comments
Master Control Relay
Service Request
PID
•
•
•
•
•
•
BCD- 4
Signed Integer
Double Precision Signed Integer
Real
Real to Word
Truncate Real Number
Timer and Counters
Math and Numerical Functions
Table Functions
•
•
•
•
•
•
•
• Array Move
• Search
+, -, x, /
Modulo division
Scaling
Square Root
Trigonometric Functions
Logarithmic/Exponential
Convert Radians
GO
HOME
Enable
Input
Time
Home
Position
Axis
AX
ADO
Execute
EX
DN
Acceleration
+ Go Home
Velocity
Deceleration
Go Home
Velocity
•
•
•
•
•
•
•
WR
Home
Position
Axis
AX
ADO
EF
AC
Active
Enable
Backward
EB
ER
Error
Error
Acceleration
ACC
EI
Error ID
Deceleration
DEC
WR
Velocity
VEL
Velocity
Velocity
(pulses/sec)
ACC
DEC
Warning
Home
Offset
Axis
Axis
Direction
Output
AX
ADO
Execute
EX
DN
Done
Number of
Profiles
NP
AC
Active
Axis Direction
Input
ADI
ER
Error
Motion
Parameters
MP
EI
Distance in Pulse Counts
Blended Move (Up to 4 Moves)
www.ge-ip.com
Enable
Output
WR
Error ID
Warning
Configured
Home
Direction
Enable
Input
Home
Input
OFF
1
Velocity, pulse/sec
Move 4
Velocity
Move 3
Warning
Jog
BLENDING
Enable
Input
Move 2
Error ID
Time (seconds)
Go Home (With or without offset)
Move 1
Enable
Output
Axis
Direction
Output
JOGGING
Enable
Input
Enable
Forward
Active
EI
GHV
Time
Find Home/Go Home
Ramp
Jog
Blended Move
Stop Move
Windowing
Follower Mode
Done
ER
DEC
Time-tick Contacts
On-delay Stopwatch timer
On-delay timer
Off-delay timer
Up Counter
Down Counter
Enable
Output
Axis Direction
Output
AC
ACC
•
•
•
•
•
•
Motion Functions
New Powerful Motion Functions
+ Go Home
Velocity
Equal
Not Equal
Greater Than
Less Than
Greater or Equal
Less or Equal
Range
Time
Home
Input
ON
Axis
AX
ADO
Execute
Enable
Output
Axis
Direction
Output
EX
DN
Done
Motion
Parameters
MP
AC
Active
Final Home
Velocity
FHV
ER
Error
HO
EI
ADI
WR
Home
Offset
Axis Direction
Input
-1
FIND HOME
Error ID
Warning
Find Home
GE Intelligent Platforms Control Systems Solutions 1.135
VersaMax Nano and Micro
Programmable Controllers
Nano 10 PLCs
The palm-sized VersaMax Nano PLC is highly compact, with an all-in-one construction that
saves panel space. Installation is a breeze: simply snap it onto a DIN-rail or mount it on a
panel. Because it gives you more capabilities in a smaller, less expensive package, the Nano
PLC is ideal for high-volume applications that require low cost, compact size, and fast
processor speeds. The Nano decreases your life-cycle costs as well, with easy installation
and long-term reliability.
IC200NAL110
Product Name
Lifecycle Status
IC200NAL211
IC200NDD010
IC200NDD101
IC200NDR001
IC200NDR010
10 point (6) 12 VDC In, 10 point (6) 24 VDC In, 10 point (6) 12 VDC In, 10 point (6) 24 VDC In, 10 point (6) 24 VDC In, 10 point (6) 12 VDC In,
(1) Analog Voltage In, (1) Analog Voltage In,
(4) 12 VDC Out,
(4) 24 VDC Out,
(4) Relay Out,
(4) Relay Out,
(4) Relay Out,
(4) Relay Out,
12 VDC Powered
24 VDC Powered
24 VDC Powered
12 VDC Powered
12 VDC Powered
24 VDC Powered
Active
Active
Active
Active
Active
Active
Number of Discrete Inputs/
Outputs
6 In / 4 Out (Non
Expandable)
6 In / 4 Out (Non
Expandable)
6 In / 4 Out (Non
Expandable)
6 In / 4 Out (Non
Expandable)
6 In / 4 Out (Non
Expandable)
6 In / 4 Out (Non
Expandable)
Number of Analog Inputs/
Outputs
1 In
1 In
N/A
N/A
N/A
N/A
Physical I/O Maximum
10
10
10
10
10
10
User Program Logic Memory
(Words)
2K
2K
2K
2K
2K
2K
Registers (Words)
256
256
256
256
256
256
Yes, 2
Yes, 2
Yes, 2
Yes, 2
Yes, 2
Yes, 2
RJ-45 (RS-232)
RJ-45 (RS-232)
RJ-45 (RS-232)
RJ-45 (RS-232)
RJ-45 (RS-232)
RJ-45 (RS-232)
SNP, SNP X
(Breakless) RTU
Slave (2 and 4 wire
RTU Slave). Serial
Read and Write
SNP, SNP X
(Breakless) RTU Slave
(2 and 4 wire RTU
Slave). Serial Read
and Write
SNP, SNP X
(Breakless) RTU Slave
(2 and 4 wire RTU
Slave). Serial Read
and Write
SNP, SNP X
(Breakless) RTU Slave
(2 and 4 wire RTU
Slave). Serial Read
and Write
Analog Pots for Data Adjustment
Serial Port Connector Type
Protocols
Power Voltage
Input Power Supply Rating
SNP, SNP X
SNP, SNP X
(Breakless) RTU Slave (Breakless) RTU Slave
(2 and 4 wire RTU
(2 and 4 wire RTU
Slave). Serial Read
Slave). Serial Read and
and Write
Write
12 VDC
24 VDC
12 VDC
24 VDC
24 VDC
12 VDC
3 watts internal
3 watts internal
3 watts internal
3 watts internal
3 watts internal
3 watts internal
Input Device Voltage
12 VDC
24 VDC
12 VDC
24 VDC
24 VDC
12 VDC
Maximum Type A and
B Counters
2 Type A and
1 Type B @ 10Khz
(16 bit)
2 Type A and
1 Type B @ 10Khz
(16 bit)
2 Type A and
1 Type B @ 10Khz
(16 bit)
2 Type A and
1 Type B @ 10Khz
(16 bit)
2 Type A and
1 Type B @ 10Khz
(16 bit)
2 Type A and
1 Type B @ 10Khz
(16 bit)
Analog Input Ranges
0 to 10 VDC (8 bit)
0 to 10 VDC (8 bit)
N/A
N/A
N/A
N/A
Relay Out
Relay Out
12 VDC
24 VDC
Relay Out
Relay Out
2 Amps at 5 VDC
and 240 VAC
2 Amps at 5 VDC
and 240 VAC
N/A
N/A
2 Amps at 5 VDC
and 240 VAC
2 Amps at 5 VDC
and 240 VAC
0
0
3 @ 5Khz (16 bit)
3 @ 5Khz (16 bit)
0
0
Output Control Voltage
Relay Maximum Resistive
Load Rating
Maximum Number of
PWM/Pulse Outputs
Dimensions (WxHxD) mm
75x80x47
75x80x47
75x80x47
75x80x47
75x80x47
75x80x47
Operating Temperature
0°C to +55°C
0°C to +55°C
0°C to +55°C
0°C to +55°C
0°C to +55°C
0°C to +55°C
Programming Software
VersaPro 2.0 or
greater, Proficy
Machine Edition
Logic Developer
VersaPro 2.0 or
greater, Proficy
Machine Edition
Logic Developer
VersaPro 1.1 or
greater, Proficy
Machine Edition
Logic Developer
VersaPro 1.1 or
greater, Proficy
Machine Edition
Logic Developer
VersaPro 1.1 or
greater, Proficy
Machine Edition
Logic Developer
VersaPro 1.1 or
greater, Proficy
Machine Edition
Logic Developer
No
No
No
No
No
No
Portable Memory
Module Support
1.136
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Micro 14 PLCs
The Micro 14 PLC is big on features; from up to 14 I/O built-in (expandable to 126 I/O)
points to fast cycle times, robust instruction set, and generous memory to allow more
flexible programming. And it’s all packaged in a sturdy modular design for easy access
and long-term durability. This all-in-one PLC gives you everything you need to ­control a
wide variety of applications.
Product Name
Lifecycle Status
IC200UAA003
IC200UAR014
IC200UDD104
IC200UDD112
14 point (8) 120 VAC In,
(6) 120 VAC Out,
120/240 VAC Powered
14 point, (8) 120 VAC In,
(6) Relay Out,
120/240 VAC Powered
14 point (8) 24 VDC In,
(6) 12/24 VDC Out,
(2) @ 1.0 A, (4) @ 0.5 A,
24 VDC Powered
14 point (8) 12 VDC In,
(6) 12 VDC Out, 0.7 A,
12 VDC Powered
Active
Active
Active
Active
Number of Discrete Inputs/Outputs
8 In / 6 Out
(Supports 4 Expansion Units)
8 In / 6 Out
(Supports 4 Expansion Units)
8 In / 6 Out
(Supports 4 Expansion Units)
8 In / 6 Out
(Supports 4 Expansion Units)
Number of Analog Inputs/Outputs
Supports up to
4 analog expansion units
(16 analog in/ 8 analog out)
Supports up to
4 analog expansion units
(16 analog in/ 8 analog out)
Supports up to
4 analog expansion units
(16 analog in/ 8 analog out)
Supports up to
4 analog expansion units
(16 analog in/ 8 analog out)
Physical I/O Maximum
126
126
126
126
User Program Logic Memory (Words)
9K
9K
9K
9K
Registers (Words)
256
256
256
256
Analog Pots for Data Adjustment
Serial Port Connector Type
Protocols
Power Voltage
Input Power Supply Rating
24 VDC User Power for Sensors
Input Device Voltage
Maximum Type A and B Counters
Output Control Voltage
Relay Maximum Resistive
Load Rating
Maximum Number of PWM/Pulse Outputs
Dimensions (WxHxD) mm
Programming Software
Portable Memory Module Support
www.ge-ip.com
Yes, 2
Yes, 2
Yes, 2
Yes, 2
RJ-45 (RS-232)
RJ-45 (RS-232)
RJ-45 (RS-232)
RJ-45 (RS-232)
SNP, SNP X (Breakless)
RTU Slave (2 and 4 wire
RTU Slave). Serial Read
and Write
SNP, SNP X (Breakless)
RTU Slave (2 and 4 wire
RTU Slave). Serial Read
and Write
SNP, SNP X (Breakless)
RTU Slave (2 and 4 wire
RTU Slave). Serial Read
and Write
SNP, SNP X (Breakless)
RTU Slave (2 and 4 wire
RTU Slave). Serial Read
and Write
120/240 VAC
120/240 VAC
24 VDC
12 VDC
11 VA
11 VA
4 Watts
3 Watts
N/A
200 mA
200 mA
200 mA
120 VAC
120 VAC
24 VDC
12 VDC
N/A
4 Type A and 1 Type B
@ 10Khz (16 bit)
4 Type A and 1 Type B
@ 10Khz (16 bit)
120 VAC
N/A
24 VDC
12 VDC
N/A
6 @ 2 Amps at 24 VDC and 240
VAC; 2 @10 Amps at 24 VDC
and 240 VAC
N/A
N/A
4 @ 5Khz (16 bit)
N/A
N/A
N/A
4 @ 5Khz (16 bit)
95x90x76
95x90x76
95x90x76
95x90x76
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
No
No
No
No
GE Intelligent Platforms Control Systems Solutions 1.137
VersaMax Nano and Micro
Programmable Controllers
Micro 14 PLCs
The Micro 14 PLC is big on features; from up to 14 I/O built-in (expandable to 126 I/O)
points to fast cycle times, robust instruction set, and generous memory to allow more
flexible programming. And it’s all packaged in a sturdy modular design for easy access
and long-term durability. This all-in-one PLC gives you everything you need to ­control a
wide variety of applications.
Product Name
IC200UDR001
IC200UDR002
IC200UDR003
14 point (8) 24 VDC In,
(6) Relay Out,
120/240 VAC Powered
14 point (8) 24 VDC In,
(6) Relay Out,
24 VDC Powered
14 point (8) 12 VDC In,
(6) Relay Out,
12 VDC Powered
Lifecycle Status
Active
Active
Active
Number of Discrete Inputs/Outputs
8 In / 6 Out
(Supports 4 Expansion Units)
8 In / 6 Out
(Supports 4 Expansion Units)
8 In / 6 Out
(Supports 4 Expansion Units)
Number of Analog Inputs/Outputs
Supports up to
4 analog expansion units
(16 analog in/ 8 analog out)
Supports up to
4 analog expansion units
(16 analog in/ 8 analog out)
Supports up to
4 analog expansion units
(16 analog in/ 8 analog out)
Physical I/O Maximum
126
126
126
User Program Logic Memory (Words)
9K
9K
9K
Registers (Words)
256
256
256
Analog Pots for Data Adjustment
Yes, 2
Yes, 2
Yes, 2
RJ-45 (RS-232)
RJ-45 (RS-232)
RJ-45 (RS-232)
SNP, SNP X (Breakless)
RTU Slave (2 and 4 wire
RTU Slave). Serial Read
and Write
SNP, SNP X (Breakless)
RTU Slave (2 and 4 wire
RTU Slave). Serial Read
and Write
SNP, SNP X (Breakless)
RTU Slave (2 and 4 wire
RTU Slave). Serial Read
and Write
Serial Port Connector Type
Protocols
Power Voltage
120/240 VAC
24 VDC
12 VDC
13 VA
4 Watts
3 Watts
24 VDC User Power for Sensors
200 mA
200 mA
200 mA
Input Device Voltage
24 VDC
24 VDC
12 VDC
4 Type A and 1 Type B
@ 10Khz (16 bit)
4 Type A and 1 Type B
@ 10Khz (16 bit)
4 Type A and 1 Type B
@ 10Khz (16 bit)
Input Power Supply Rating
Maximum Type A and B Counters
Output Control Voltage
Relay Maximum Resistive
Load Rating
Maximum Number of PWM/Pulse Outputs
Relay Out
2 Amps at 24 VDC
and 240 VAC
0
0
0
95x90x76
95x90x76
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
No
No
No
Portable Memory Module Support
1.138
Relay Out
2 Amps at 24 VDC
and 240 VAC
95x90x76
Dimensions (WxHxD) mm
Programming Software
Relay Out
2 Amps at 24 VDC
and 240 VAC
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Micro 23 PLCs
The Micro 23 PLC is big on features with 23 discrete I/O and two analog inputs and one
analog output built-in (expandable to 135 I/O) points. The Micro 23 executes fast cycle
times, robust instruction set, and generous memory to allow more flexible programming.
And it’s all packaged in a sturdy modular design for easy access and long-term durability.
Product Name
Lifecycle Status
IC200UAL004
IC200UAL005
IC200UAL006
23 point; (13) 12 VDC In,
(10) Relay Out,
(2) Analog In and (1) Analog Out,
12 VDC Powered.
23 point; (13) 24 VDC In,
(9) Relay Out, (1) 24 VDC Out,
(2) Analog In and (1) Analog Out, 24
VDC Powered.
23 point; (13) 24 VDC In,
(9) Relay Out, (1) 24 VDC Out,
(2) Analog In and (1) Analog Out,
120/240 VAC Powered.
Active
Active
Active
Number of Discrete Inputs/Outputs
13 In / 10 Out
(Supports 4 Expansion Units)
13 In / 10 Out
(Supports 4 Expansion Units)
13 In / 10 Out
(Supports 4 Expansion Units)
Number of Analog Inputs/Outputs
2 analog in / 1 analog out built-in and
supports up to 4 analog expansion
units (16 analog in/ 8 analog out)
2 analog in / 1 analog out built-in and
supports up to 4 analog expansion
units (16 analog in/ 8 analog out)
2 analog in / 1 analog out built-in and
supports up to 4 analog expansion
units (16 analog in/ 8 analog out)
Physical I/O Maximum
135
135
135
User Program Logic Memory (Words)
9K
9K
9K
Registers (Words)
2K
2K
2K
Analog Pots for Data Adjustment
Serial Port Connector Type
Protocols
Yes, 2
Yes, 2
Yes, 2
RJ-45 (RS-232) port 1 and
DB-15 (RS-485 on port 2)
RJ-45 (RS-232) port 1 and
DB-15 (RS-485 on port 2)
RJ-45 (RS-232) port 1 and
DB-15 (RS-485 on port 2)
Port 1, SNP, SNP X (Breakless);
Port 2, SNP, SNP X (Breakless),
RTU Master and Slave
(2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write
Port 1, SNP, SNP X (Breakless);
Port 2, SNP, SNP X (Breakless),
RTU Master and Slave
(2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write
Port 1, SNP, SNP X (Breakless);
Port 2, SNP, SNP X (Breakless),
RTU Master and Slave
(2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write
120/240 VAC
Power Voltage
12 VDC
24 VDC
Input Power Supply Rating
8 Watts
8 Watts
34 VA
24 VDC User Power for Sensors
200 mA
200 mA
200 mA
Input Device Voltage
Maximum Type A and B Counters
Analog Input Ranges
Output Control Voltage
Relay Maximum Resistive
Load Rating
Maximum Number of PWM/Pulse Outputs
Analog Output Ranges
Dimensions (WxHxD) mm
Programming Software
Portable Memory Module Support
www.ge-ip.com
12 VDC
24 VDC
24 VDC
4 Type A and 1 Type B
@ 10Khz (16 bit)
4 Type A and 1 Type B
@ 10Khz (16 bit)
4 Type A and 1 Type B
@ 10Khz (16 bit)
0 to 10 VDC (10.24V max.) 0 to 20 mA
(20.5 mA max.) 4 to 20 mA (20.5 mA
max.); 12 bit Resolution
0 to 10 VDC (10.24V max.) 0 to 20 mA
(20.5 mA max.) 4 to 20 mA (20.5 mA
max.); 12 bit Resolution
0 to 10 VDC (10.24V max.) 0 to 20 mA
(20.5 mA max.) 4 to 20 mA (20.5 mA
max.); 12 bit Resolution
Relay Out
Relay Out
Relay Out
2 Amps at 24 VDC
and 240 VAC
2 Amps at 24 VDC
and 240 VAC
2 Amps at 24 VDC
and 240 VAC
N/A
1 @ 5Khz (16 bit)
1 @ 5Khz (16 bit)
0 to 10 VDC (10.24V max.) 0 to 20 mA
(20.5 mA max.) 4 to 20 mA
(20.5 mA max.); 12 bit Resolution
0 to 10 VDC (10.24V max.) 0 to 20 mA
(20.5 mA max.) 4 to 20 mA
(20.5 mA max.); 12 bit Resolution
0 to 10 VDC (10.24V max.) 0 to 20 mA
(20.5 mA max.) 4 to 20 mA
(20.5 mA max.); 12 bit Resolution
150x90x76
150x90x76
150x90x76
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
No
No
No
GE Intelligent Platforms Control Systems Solutions 1.139
VersaMax Nano and Micro
Programmable Controllers
Micro 28 PLC
The Micro 28 PLC is big on features with the built-in 28 I/O (expandable to 140 I/O) points
to fast cycle times, two built-in serial ports, robust instruction set, and generous memory
to allow more flexible programming. And it’s all packaged in a sturdy modular design for
easy access and long-term durability. This all-in-one PLC gives you everything you need
to control a wide variety of applications.
Product Name
Lifecycle Status
IC200UAA007
IC200UAR028
28 point; (16) 120 VAC In,
(12) 120 VAC Out,
120/240 VAC Powered.
28 point, (16) 120 VAC In,
(12) Relay Out,
120/240 VAC Powered.
IC200UDD110
IC200UDD120
28 point; (16) 24 VDC In,
28 point; (16) 24 VDC In,
(12) 24 VDC Out (6) @ 1.0 A, (6) (12) 24 VDC Out (6) @ 1.0 A, (6)
@ 0.5 A, 24 VDC Powered.
@ 0.5 A, 24 VDC Powered.
Active
Active
Active
Active
16 In / 12 Out
(Supports 4 Expansion Units)
16 In / 12 Out
(Supports 4 Expansion Units)
16 In / 12 Out
(Supports 4 Expansion Units)
16 In / 12 Out
(Supports 4 Expansion Units)
Supports up to 4 analog
expansion units
(16 analog in/ 8 analog out)
Supports up to 4 analog
expansion units
(16 analog in/ 8 analog out)
Supports up to 4 analog
expansion units
(16 analog in/ 8 analog out)
Supports up to 4 analog
expansion units
(16 analog in/ 8 analog out)
Physical I/O Maximum
140
140
140
140
User Program Logic Memory (Words)
9K
9K
9K
9K
Registers (Words)
2K
2K
2K
2K
Yes, 2
Yes, 2
Yes, 2
Yes, 2
RJ-45 (RS-232) port 1 and
DB-15 (RS-485 on port 2)
RJ-45 (RS-232) port 1 and
DB-15 (RS-485 on port 2)
RJ-45 (RS-232) port 1 and
DB-15 (RS-485 on port 2)
RJ-45 (RS-232) port 1 and
DB-15 (RS-485 on port 2)
Port 1, SNP, SNP X (Breakless);
Port 2, SNP, SNP X (Breakless),
RTU Master and Slave
(2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write
Port 1, SNP, SNP X (Breakless);
Port 2, SNP, SNP X (Breakless),
RTU Master and Slave
(2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write
Port 1, SNP, SNP X (Breakless);
Port 2, SNP, SNP X (Breakless),
RTU Master and Slave
(2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write
Port 1, SNP, SNP X (Breakless);
Port 2, SNP, SNP X (Breakless),
RTU Master and Slave
(2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write
120/240 VAC
120/240 VAC
24 VDC
24 VDC
16 VA
16 VA
5 Watts
5 Watts
200 mA
Number of Discrete Inputs/Outputs
Number of Analog Inputs/Outputs
Analog Pots for Data Adjustment
Serial Port Connector Type
Protocols
Power Voltage
Input Power Supply Rating
24 VDC User Power for Sensors
Input Device Voltage
Maximum Type A and B Counters
Output Control Voltage
Relay Maximum Resistive
Load Rating
Maximum Number of
PWM/Pulse Outputs
Dimensions (WxHxD) mm
Programming Software
Portable Memory Module Support
1.140
N/A
200 mA
200 mA
120 VAC
120 VAC
24 VDC
24 VDC
N/A
N/A
4 Type A and 1 Type B
@ 10Khz (16 bit)
4 Type A and 1 Type B
@ 10Khz (16 bit)
120 VAC
Relay Out
24 VDC
24 VDC ESCP, Self Healing,
No External Fusing Required
N/A
10 @ 2 Amps at 24 VDC and
240 VAC; 2 @ 10 Amps at
24 VDC and 240 VAC
N/A
N/A
N/A
N/A
4 @ 5Khz (16 bit)
4 @ 5Khz (16 bit)
150x90x76
150x90x76
150x90x76
150x90x76
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
No
No
No
No
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Micro 28 PLC
The Micro 28 PLC is big on features with the built-in 28 I/O (expandable to 140 I/O) points
to fast cycle times, two built-in serial ports, robust instruction set, and generous memory
to allow more flexible programming. And it’s all packaged in a sturdy modular design for
easy access and long-term durability. This all-in-one PLC gives you everything you need
to control a wide variety of applications.
Product Name
Lifecycle Status
IC200UDD212
IC200UDR005
IC200UDR006
IC200UDR228
IC200UDR010
28 point (16) 12 VDC In,
(12) 12 VDC Out, 0.7A,
12 VDC Powered
28 point (16) 24 VDC In,
(11) Relay Out,
(1) 24 VDC Out,
120/240 VAC Powered
28 point (16) 12 VDC In,
(12) Relay Out,
12 VDC Powered
28 point (16) 24 VDC In,
(11) Relay Out,
(1) 24 VDC OUT,
12/24 VDC Powered
28 point (16) 24 VDC In,
(11) Relay Out,
(1) 24 VDC OUT,
24 VDC Powered
Active
Active
Active
Active
Active
Number of Discrete Inputs/Outputs
16 In / 12 Out
(Supports 4
Expansion Units)
16 In / 12 Out
(Supports 4
Expansion Units
16 In / 12 Out
(Supports 4
Expansion Units
16 In / 12 Out
(Supports 4
Expansion Units
16 In / 12 Out
(Supports 4
Expansion Units
Number of Analog Inputs/Outputs
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Physical I/O Maximum
140
140
140
140
140
User Program Logic Memory (Words)
9K
9K
9K
9K
9K
Registers (Words)
2K
2K
2K
2K
2K
Yes, 2
Yes, 2
Yes, 2
Yes, 2
Yes, 2
Analog Pots for Data Adjustment
Serial Port Connector Type
RJ-45 (RS-232) port 1 and RJ-45 (RS-232) port 1 and RJ-45 (RS-232) port 1 and RJ-45 (RS-232) port 1 and RJ-45 (RS-232) port 1 and
DB-15 (RS-485 on port 2) DB-15 (RS-485 on port 2) DB-15 (RS-485 on port 2) DB-15 (RS-485 on port 2) DB-15 (RS-485 on port 2)
Protocols
Port 1, SNP, SNP X
(Breakless); Port 2,
SNP, SNP X (Breakless),
RTU Master and Slave
(2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write
Port 1, SNP, SNP X
(Breakless); Port 2,
SNP, SNP X (Breakless),
RTU Master and Slave
(2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write
Power Voltage
12 VDC
Input Power Supply Rating
8 Watts
24 VDC User Power for Sensors
Input Device Voltage
Maximum Type A and B Counters
Output Control Voltage
Relay Maximum Resistive
Load Rating
Maximum Number of
PWM/Pulse Outputs
Dimensions (WxHxD) mm
Programming Software
Portable Memory Module Support
www.ge-ip.com
Port 1, SNP, SNP X
(Breakless); Port 2,
SNP, SNP X (Breakless),
RTU Master and Slave
(2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write
Port 1, SNP, SNP X
(Breakless); Port 2,
SNP, SNP X (Breakless),
RTU Master and Slave
(2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write
120/240 VAC
12 VDC
12/24 VDC
24 VDC
26 VA
8 Watts
8 Watts
8 Watts
200 mA
200 mA
200 mA
140 mA
200 mA
12 VDC
24 VDC
12 VDC
24 VDC
24 VDC
4 Type A and 1 Type B
@ 10Khz (16 bit)
4 Type A and 1 Type B
@ 10Khz (16 bit)
4 Type A and 1 Type B
@ 10Khz (16 bit)
4 Type A and 1 Type B
@ 10Khz (16 bit)
4 Type A and 1 Type B
@ 10Khz (16 bit)
12 VDC
Relay Out
Relay Out
Relay Out
Relay Out
N/A
2 Amps at 24 VDC
and 240 VAC
2 Amps at 24 VDC
and 240 VAC
2 Amps at 24 VDC
and 240 VAC
2 Amps at 24 VDC
and 240 VAC
4 @ 5Khz (32 bit)
1 @ 5Khz (16 bit)
1 @ 5Khz (16 bit)
1 @ 5Khz (16 bit)
1 @ 5Khz (16 bit)
Port 1, SNP, SNP X
(Breakless); Port 2,
SNP, SNP X (Breakless),
RTU Master and Slave
(2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write
150x90x76
150x90x76
150x90x76
150x90x76
150x90x76
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
VersaPro 1.1 or greater,
Proficy Machine Edition
Logic Developer
No
No
No
No
GE Intelligent Platforms Control Systems Solutions 1.141
VersaMax Nano and Micro
Programmable Controllers
Micro 20 PLC
The Micro 20 PLC is big on features, expandable to 132 I/O points to fast cycle times, robust
instruction set, and generous memory to allow more flexible programming. The optional second port provides you with the option of an additional RS-232 port, RS-485, USB, or Ethernet.
The serial expansion ports come with two analog input channels. A user-friendly memory
module is available to easily download changes to the controller without the need of a PC.
And it’s all packaged in a sturdy modular design for easy access and long-term durability.
This all-in-one PLC gives you everything you need to control a wide variety of applications.
Product Name
Lifecycle Status
IC200UDD020
IC200UDD220
IC200UDR120
IC200UDR020
Micro 20; (12) 24 VDC In,
(8) 24 VDC Source Out 0.7
amps with ESCP protection,
24 VDC Powered
Micro 20; (12) 24 VDC In,
(8) 24 VDC Sink Out,
24 VDC Powered
Micro 20; (12) 24 VDC In,
(8) Relay Out 2.0 amps,
120/240VAC Powered
Micro 20; (12) 24 VDC In,
(8) Relay Out 2.0 amps,
24VDC Powered
Active
Active
Active
Active
Number of Discrete Inputs/Outputs
12 In / 8 Out
(Supports 4 Expansion Units)
12 In / 8 Out
(Supports 4 Expansion Units)
12 In / 8 Out
(Supports 4 Expansion Units)
12 In / 8 Out
(Supports 4 Expansion Units)
Number of Analog Inputs/Outputs
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Physical I/O Maximum
132
132
132
132
User Program Logic Memory (Words)
24 K
24 K
24 K
24 K
Registers (Words)
32 K
32 K
32 K
32 K
No
No
No
No
RJ-45 (RS-232) port 1 and
optional port 2 DB-15 (RS-485)
or RJ-45 (RS-232) or USB or
RJ-45 (Ethernet 10/100Mbit)
RJ-45 (RS-232) port 1 and
optional port 2 DB-15 (RS-485)
or RJ-45 (RS-232) or USB or
RJ-45 (Ethernet 10/100Mbit)
RJ-45 (RS-232) port 1 and
optional port 2 DB-15 (RS-485)
or RJ-45 (RS-232) or USB or
RJ-45 (Ethernet 10/100Mbit)
RJ-45 (RS-232) port 1 and
optional port 2 DB-15 (RS-485)
or RJ-45 (RS-232) or USB or
RJ-45 (Ethernet 10/100Mbit)
Both Ports: SNP, SNP X
(Breakless), RTU Master and
Slave 2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write; Ethernet SRTP,
Modbus TCP (server)
and Tunneling
Both Ports: SNP, SNP X
(Breakless), RTU Master and
Slave 2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write; Ethernet SRTP,
Modbus TCP (server)
and Tunneling
Both Ports: SNP, SNP X
(Breakless), RTU Master and
Slave 2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write; Ethernet SRTP,
Modbus TCP (server)
and Tunneling
Both Ports: SNP, SNP X
(Breakless), RTU Master and
Slave 2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write; Ethernet SRTP,
Modbus TCP (server)
and Tunneling
Analog Pots for Data Adjustment
Serial Port Connector Type
Protocols
Power Voltage
24 VDC
24 VDC
120/240 VAC
24 VDC
Input Power Supply Rating
10 Watts
10 Watts
35 VA
10 Watts
24 VDC User Power for Sensors
435 mA
435 mA
435 mA
435 mA
Input Device Voltage
24 VDC
24 VDC
24 VDC
24 VDC
4 Type A and 1 Type B
@ 100Khz (32 bit)
4 Type A and 1 Type B
@ 100Khz (32 bit)
4 Type A and 1 Type B
@ 100Khz (32 bit)
4 Type A and 1 Type B
@ 100Khz (32 bit)
24 VDC ESCP; Self Healing;
No External Fusing Required
24 VDC Sink
Relay Out
Relay Out
N/A
N/A
2 Amps at 24 VDC
and 240 VAC
2 Amps at 24 VDC
and 240 VAC
4 @ 65Khz (32 bit)
4 @ 65Khz (32 bit)
N/A
N/A
Maximum Type A and B Counters
Output Control Voltage
Relay Maximum Resistive
Load Rating
Maximum Number of
PWM/Pulse Outputs
Dimensions (WxHxD) mm
Programming Software
Portable Memory Module Support
1.142
150x90x76
150x90x76
150x90x76
150x90x76
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
Yes
Yes
Yes
Yes
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Micro 40 PLC
The Micro 40 PLC is big on features, expandable to 152 I/O points to fast cycle times, robust
instruction set, and generous memory to allow more flexible programming. The optional second port provides you with the option of an additional RS-232 port, RS-485, USB, or Ethernet.
The serial expansion ports come with two analog input channels. A user-friendly memory
module is available to easily download changes to the controller without the need of a PC.
And it’s all packaged in a sturdy modular design for easy access and long-term durability.
This all-in-one PLC gives you everything you need to control a wide variety of applications.
IC200UDD040
IC200UDD240
IC200UDR140
IC200UDR040
IC200UDR440
Product Name
Micro 40; (24) 24 VDC In,
(16) 24 VDC Source Out,
0.7 amps with ESCP protection, 24 VDC Powered
Micro 40; (24) 24 VDC In,
(16) 24 VDC Sink Out,
24 VDC Powered
Micro 40; (24) 24 VDC In,
(16) Relay Out 2.0 amps,
120/240 VAC Powered
Micro 40; (24) 24 VDC In,
(16) Relay Out 2.0 amps,
24 VDC Powered
Micro 40; (24) 24 VDC In,
(16) Relay Out 2.0 amps
12/24 VDC Powered
Lifecycle Status
Active
Active
Active
Active
Active
Number of Discrete Inputs/Outputs
24 In / 16 Out (Supports 4 24 In / 16 Out (Supports 4 24 In / 16 Out (Supports 4 24 In / 16 Out (Supports 4 24 In / 16 Out (Supports 4
Expansion Units)
Expansion Units)
Expansion Units)
Expansion Units)
Expansion Units)
Number of Analog Inputs/Outputs
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Physical I/O Maximum
152
152
152
152
152
User Program Logic Memory (Words)
24 K
24 K
24 K
24 K
24 K
Registers (Words)
32 K
32 K
32 K
32 K
32 K
No
No
No
No
No
Analog Pots for Data Adjustment
Serial Port Connector Type
Protocols
Power Voltage
RJ-45 (RS-232) port 1
RJ-45 (RS-232) port 1
RJ-45 (RS-232) port 1
RJ-45 (RS-232) port 1
RJ-45 (RS-232) port 1
and optional port 2 DB-15 and optional port 2 DB-15 and optional port 2 DB-15 and optional port 2 DB-15 and optional port 2 DB-15
(RS-485) or RJ-45 (RS-232) (RS-485) or RJ-45 (RS-232) (RS-485) or RJ-45 (RS-232) (RS-485) or RJ-45 (RS-232) (RS-485) or RJ-45 (RS-232)
or USB or RJ-45
or USB or RJ-45
or USB or RJ-45
or USB or RJ-45
or USB or RJ-45
(Ethernet 10/100Mbit)
(Ethernet 10/100Mbit)
(Ethernet 10/100Mbit)
(Ethernet 10/100Mbit)
(Ethernet 10/100Mbit)
Both Ports: SNP, SNP X
(Breakless), RTU Master
and Slave (2 and 4 wire
RTU Slave), SNP Master,
Serial Read and Write;
Ethernet SRTP,
Modbus TCP (server)
and Tunneling
Both Ports: SNP, SNP X
(Breakless), RTU Master
and Slave (2 and 4 wire
RTU Slave), SNP Master,
Serial Read and Write;
Ethernet SRTP,
Modbus TCP (server)
and Tunneling
Both Ports: SNP, SNP X
(Breakless), RTU Master
and Slave (2 and 4 wire
RTU Slave), SNP Master,
Serial Read and Write;
Ethernet SRTP,
Modbus TCP (server)
and Tunneling
Both Ports: SNP, SNP X
(Breakless), RTU Master
and Slave (2 and 4 wire
RTU Slave), SNP Master,
Serial Read and Write;
Ethernet SRTP,
Modbus TCP (server)
and Tunneling
Both Ports: SNP, SNP X
(Breakless), RTU Master
and Slave (2 and 4 wire
RTU Slave), SNP Master,
Serial Read and Write;
Ethernet SRTP,
Modbus TCP (server)
and Tunneling
24 VDC
24 VDC
120/240 VAC
24 VDC
12/24 VDC
Input Power Supply Rating
10 Watts
10 Watts
35 VA
10 Watts
10 Watts
24 VDC User Power for Sensors
435 mA
435 mA
435 mA
435 mA
120 mA
Input Device Voltage
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
4 Type A and 1 Type B
@ 100Khz (32 bit)
4 Type A and 1 Type B
@ 100Khz (32 bit)
4 Type A and 1 Type B
@ 100Khz (32 bit)
4 Type A and 1 Type B
@ 100Khz (32 bit)
4 Type A and 1 Type B
@ 100Khz (32 bit)
24 VDC ESCP;
Self Healing; No External
Fusing Required
24 VDC Sink
Relay Out
Relay Out
Relay Out
N/A
N/A
2 Amps at 24 VDC
and 240 VA
2 Amps at 24 VDC
and 240 VA
2 Amps at 24 VDC
and 240 VA
4 @ 65Khz (32 bit)
4 @ 65Khz (32 bit)
N/A
N/A
N/A
Maximum Type A and B Counters
Output Control Voltage
Relay Maximum Resistive
Load Rating
Maximum Number of
PWM/Pulse Outputs
Dimensions (WxHxD) mm
Programming Software
Portable Memory Module Support
www.ge-ip.com
150x90x76
150x90x76
150x90x76
150x90x76
150x90x76
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
Yes
Yes
Yes
Yes
Yes
GE Intelligent Platforms Control Systems Solutions 1.143
VersaMax Nano and Micro
Programmable Controllers
Micro 64 PLC
The Micro 64 PLC is big on features, expandable to 176 I/O points to fast cycle times, robust
instruction set, and generous memory to allow more flexible programming. The optional second
port provides you with the option of an additional RS-232 port, RS-485, USB, or Ethernet. The
serial expansion ports come with two analog input channels. A user-friendly memory module
is available to easily download changes to the controller without the need of a PC. And it’s all
packaged in a sturdy modular design for easy access and long-term durability. This all-in-one
PLC gives you everything you need to control a wide variety of applications.
Product Name
Lifecycle Status
IC200UDD064
IC200UDD164
IC200UDR164
IC200UDR064
Micro 64; (40) 24 VDC In,
(24) 24 VDC Source Out
0.7 amps with ESCP protection, 24 VDC Powered.
Micro 64; (40) 24 VDC In,
(24) 24 VDC Sink Out
0.7 amps,
24 VDC Powered.
Micro 64; (40) 24 VDC In,
(24) Relay Out 2.0 amps,
120/240 VAC Powered.
Micro 64; (40) 24 VDC In,
(24) Relay Out 2.0 amps,
24 VDC Powered.
Active
Active
Active
Active
Number of Discrete Inputs/Outputs
40 In / 24 Out
(Supports 4 Expansion Units)
40 In / 24 Out
(Supports 4 Expansion Units)
40 In / 24 Out
(Supports 4 Expansion Units)
40 In / 24 Out
(Supports 4 Expansion Units)
Number of Analog Inputs/Outputs
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Supports up to 4 analog
expansion units
(16 analog in/
8 analog out)
Physical I/O Maximum
176
176
176
176
User Program Logic Memory (Words)
24K
24K
24 K
24 K
Registers (Words)
32 K
32 K
32 K
32 K
No
No
No
No
RJ-45 (RS-232) port 1
and optional port 2 DB-15
(RS-485) or RJ-45 (RS-232)
or USB or RJ-45
(Ethernet 10/100 Mbit)
RJ-45 (RS-232) port 1
and optional port 2 DB-15
(RS-485) or RJ-45 (RS-232)
or USB or RJ-45
(Ethernet 10/100 Mbit)
RJ-45 (RS-232) port 1
and optional port 2 DB-15
(RS-485) or RJ-45 (RS-232)
or USB or RJ-45
(Ethernet 10/100 Mbit)
RJ-45 (RS-232) port 1
and optional port 2 DB-15
(RS-485) or RJ-45 (RS-232)
or USB or RJ-45
(Ethernet 10/100 Mbit)
Both Ports: SNP, SNP X
(Breakless), RTU Master and
Slave (2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write; Ethernet SRTP,
Modbus TCP (server)
and Tunneling
Both Ports: SNP, SNP X
(Breakless), RTU Master and
Slave (2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write; Ethernet SRTP,
Modbus TCP (server)
and Tunneling
Both Ports: SNP, SNP X
(Breakless),RTU Master and
Slave (2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write; Ethernet SRTP,
Modbus TCP (server)
and Tunneling
Both Ports: SNP, SNP X
(Breakless),RTU Master and
Slave (2 and 4 wire RTU Slave),
SNP Master, Serial Read
and Write; Ethernet SRTP,
Modbus TCP (server)
and Tunneling
Analog Pots for Data Adjustment
Serial Port Connector Type
Protocols
Power Voltage
24 VDC
24 VDC
120/240 VAC
24 VDC
Input Power Supply Rating
10 Watts
10 Watts
35 VA
10 Watts
24 VDC User Power for Sensors
435 mA
435 mA
435 mA
435 mA
Input Device Voltage
24 VDC
24 VDC
24 VDC
24 VDC
4 Type A and 1 Type B
@ 100Khz (32 bit)
4 Type A and 1 Type B
@ 100Khz (32 bit)
4 Type A and 1 Type B
@ 100Khz (32 bit)
4 Type A and 1 Type B
@ 100Khz (32 bit)
24 VDC ESCP,
Self Healing, No External
Fusing Required
24 VDC Sink
Relay Out
Relay Out
N/A
N/A
2 Amps at 24 VDC
and 240 VAC
2 Amps at 24 VDC
and 240 VAC
4 @ 65Khz (32 bit)
4 @ 65Khz (32 bit)
N/A
N/A
Maximum Type A and B Counters
Output Control Voltage
Relay Maximum Resistive
Load Rating
Maximum Number of
PWM/Pulse Outputs
Dimensions (WxHxD) mm
Programming Software
Portable Memory Module Support
1.144
190x90x76
190x90x76
190x90x76
190x90x76
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
Yes
Yes
Yes
Yes
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Discrete Expansion Selection Guide
Model
Module
Input
Power
IC200UEI08
24 VDC
8 Inputs
IC200UEI016
24 VDC
16 Inputs
IC200UEO008
24 VDC
8 Outputs
IC200UEO016
24 VDC
16 Outputs
IC200UEO108
24 VDC
8 Outputs
IC200UEO116
24 VDC
16 Outputs
IC200UER508
24 VDC
IC200UER008
24 VDC
IC200UER016
24 VDC
IC200UEC008
24 VDC
4 Inputs/
4 Source
Outputs
IC200UEC108
24 VDC
4 Inputs/ 4 Sink
Outputs
IC200UEC208
24 VDC
4 Inputs/ 4
Relay Outputs
IC200UEX015
12 VDC
IC200UEX013
12 VDC
IC200UEX014
24 VDC
8 Inputs/ 6
24 VDC Outputs
IC200UEX122
24 VDC
8 Inputs/ 6
24 VDC Outputs
with ESCP
IC200UEX012
24 VDC
8 Inputs/ 6
Relay Outputs
8 Inputs/ 6
Relay Outputs
IC200UEX011
120/240 VAC
8 Inputs/ 6
Relay Outputs
8 Inputs/ 6
Relay Outputs
IC200UEX009
120/240 VAC
8 Inputs/ 6
Relay Outputs
(4 @ 2 amps
and 2 @ 10
amps)
IC200UEX010
120/240 VAC
8 Inputs/ 6 AC
Outputs
IC200UEX215
12 VDC
IC200UEX213
12 VDC
IC200UEX214
24 VDC
16 Inputs/ 12
24 VDC Outputs
IC200UEX222
24 VDC
16 Inputs/ 12
24 VDC Outputs
with ESCP
IC200UEX212
24 VDC
16 Inputs/ 12
Relay Outputs
16 Inputs/ 12
Relay Outputs
IC200UEX211
120/240 VAC
16 Inputs/ 12
Relay Outputs
16 Inputs/ 12
Relay Outputs
IC200UEX209
120/240 VAC
16 Inputs/ 12
Relay Outputs
(10 @ 2 amps
and 2 @
10 amps)
IC200UEX210
120/240 VAC
16 Inputs/ 12
AC Outputs
IC200UEX264*
24 VDC
40 Inputs/ 24
24 VDC Outputs
IC200UEX364*
24 VDC
40 Inputs/ 24
24 VDC Outputs
IC200UEX064*
24 VDC
40 Inputs/ 24
Relay Outputs
40 Inputs/ 24
Relay Outputs
40 Inputs/ 24
Relay Outputs
40 Inputs/ 24
Relay Outputs
12 VDC
Inputs
12 VDC
Outputs
24 VDC
Inputs
120 VAC
Input
24 VDC
Outputs
Source
24 VDC
Outputs
with ESCP
24 VDC
Sink
Outputs
120 VAC
Output
Relay
Outputs,
2 Amps
Relay
Outputs,
5 Amps
Relay
Outputs
10 Amps
8 Outputs
8 Outputs
16 Outputs
4 Inputs/
4 Source
Outputs
4 Inputs/ 4 Sink
Outputs
4 Inputs/ 4
Relay Outputs
8 Inputs/ 6
8 Inputs/ 6
12 VDC Outputs 12 VDC Outputs
8 Inputs/ 6
Relay Outputs
8 Inputs/ 6
Relay Outputs
8 Inputs/ 6
24 VDC Outputs
8 Inputs/ 6
24 VDC Outputs
with ESCP
8 Inputs/ 6
Relay Outputs
(4 @ 2 amps
and 2 @ 10
amps)
8 Inputs/ 6
Relay Outputs
(4 @ 2 amps
and 2 @ 10
amps)
8 Inputs/ 6 AC
Outputs
16 Inputs/ 12 16 Inputs/ 12
12 VDC Outputs 12 VDC Outputs
16 Inputs/ 12
Relay Outputs
IC200UEX164* 120/240 VAC
8 Inputs/ 6
Relay Outputs
16 Inputs/ 12
24 VDC Outputs
16 Inputs/ 12
24 VDC Outputs
with ESCP
16 Inputs/ 12
Relay Outputs
(10 @ 2 amps
and 2 @
10 amps)
16 Inputs/ 12
Relay Outputs
(10 @ 2 amps
and 2 @
10 amps)
16 Inputs/ 12
AC Outputs
40 Inputs/ 24
24 VDC Outputs
40 Inputs/ 24
24 VDC Outputs
* Micro 20, 40 and 64 support only.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.145
VersaMax Nano and Micro
Programmable Controllers
Discrete Expansion Units
The VersaMax Micro’s modular design provides you with remarkable flexibility in a
compact control. The versatile Micro PLC can support up to four Expansion Units of
any mix of discrete or analog.
Product Name
IC200UEI008
IC200UEI016
IC200UEO008
IC200UEO016
IC200UEO108
IC200UEO116
8 point (8)
24 VDC In,
24 VDC Powered
16 point (16)
24 VDC In,
24 VDC Powered
8 point (8) 24 VDC
Output with
ESCP Protection,
24 VDC Powered
16 point (16) 24 VDC
Output with
ESCP Protection,
24 VDC Powered
8 point (8) 24 VDC
Sink Output,
24 VDC Powered
16 point (16) 24 VDC
Sink Output,
24 VDC Powered
Active
Active
Active
Active
Active
Lifecycle Status
Micro Type Restrictions
N/A
N/A
N/A
N/A
N/A
N/A
Number of Discrete
Inputs/Outputs
8 In
16 In
8 Out
16 Out
8 Out
16 Out
Power Voltage
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
Input Power Supply Rating
4 Watts
4 Watts
4 Watts
4 Watts
4 Watts
4 Watts
24 VDC User Power for Sensors
200 mA
200 mA
200 mA
200 mA
200 mA
200 mA
Input Device Voltage
24 VDC
24 VDC
N/A
N/A
N/A
N/A
N/A
N/A
24 VDC ESCP,
Self Healing,
No External
Fusing Required
24 VDC ESCP,
Self Healing,
No External
Fusing Required
24 VDC Sink
24 VDC Sink
N/A
N/A
N/A
N/A
N/A
N/A
95x90x76
95x90x76
95x90x76
95x90x76
95x90x76
95x90x76
Output Control Voltage
Relay Maximum Resistive
Load Rating
Dimensions (WxHxD) mm
1.146
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Discrete Expansion Units
The VersaMax Micro’s modular design provides you with remarkable flexibility in a
compact control. The versatile Micro PLC can support up to four Expansion Units of
any mix of discrete or analog.
IC200UER508
Product Name
IC200UER008
8 point (8) 5 Amp
8 point (8) 2 Amp
Relay Out,
Relay Out,
24 VDC Power Supply 24 VDC Power Supply
(not UL approved)
IC200UER016
16 point (16) Relay
Out, 24 VDC
Power Supply
IC200UEC008
IC200UEC108
IC200UEC208
8 point (4) 24 VDC In, 8 point (4) 24 VDC In, 8 point (4) 24 VDC In,
(4) 24 VDC Out with
(4) 24 VDC Sink Out,
(4) Relay Out,
ESCP Protection,
24 VDC Power Supply 24 VDC Power Supply
24 VDC Power Supply
Lifecycle Status
Active
Active
Active
Active
Active
Active
Micro Type Restrictions
None
None
None
None
None
None
Number of Discrete
Inputs/Outputs
8 Out
8 Out
16 Out
4 In / 4 Out
4 In / 4 Out
4 In / 4 Out
Power Voltage
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
24 VDC
Input Power Supply Rating
4 Watts
4 Watts
4 Watts
4 Watts
4 Watts
4 Watts
24 VDC User Power for Sensors
200 mA
200 mA
200 mA
200 mA
200 mA
200 mA
Input Device Voltage
N/A
N/A
N/A
24 VDC
24 VDC
24 VDC
Relay Out
Relay Out
Relay Out
24 VDC ESCP,
Self Healing,
No External
Fusing Required
24 VDC Sink
Relay Out
5 Amps at 24 VDC
and 240 VAC
2 Amps at 24 VDC
and 240 VAC
2 Amps at 24 VDC
and 240 VAC
N/A
N/A
2 Amps at 24 VDC
and 240 VAC
95x90x76
95x90x76
95x90x76
95x90x76
95x90x76
95x90x76
Output Control Voltage
Relay Maximum Resistive
Load Rating
Dimensions (WxHxD) mm
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.147
VersaMax Nano and Micro
Programmable Controllers
Discrete Expansion Units
The VersaMax Micro’s modular design provides you with remarkable flexibility in a
compact control. The versatile Micro PLC can support up to four Expansion Units of
any mix of discrete or analog.
IC200UEX015
Product Name
Lifecycle Status
IC200UEX013
IC200UEX014
IC200UEX122
IC200UEX012
IC200UEX011
14 point (8) 12 VDC In, 14 point (8) 12 VDC In, 14 point (8) 24 VDC In, 14 point (8) 24 VDC In, 14 point (8) 24 VDC In, 14 point (8) 24 VDC
(6) 12 VDC Out,
(6) Relay Out,
(6) 24 VDC Out,
(6) 24 VDC Out
(6) Relay Out,
In, (6) Relay Out,
12 VDC Powered
12 VDC Powered
24 VDC Powered
with ESCP,
24 VDC Powered
120/240 VAC Powered
24 VDC Powered
Active
Active
Active
Active
Active
Active
N/A
N/A
N/A
N/A
N/A
N/A
8 In / 6 Out
8 In / 6 Out
8 In / 6 Out
8 In / 6 Out
8 In / 6 Out
8 In / 6 Out
Power Voltage
12 VDC
12 VDC
24 VDC
24 VDC
24 VDC
120/240 VAC
Input Power Supply Rating
4 Watts
4 Watts
4 Watts
4 Watts
4 Watts
13 VA
24 VDC User Power for Sensors
200 mA
200 mA
200 mA
200 mA
200 mA
200 mA
Input Device Voltage
12 VDC
12 VDC
24 VDC
24 VDC
24 VDC
24 VDC
12 VDC
Relay Out
24 VDC
24 VDC ESCP,
Self Healing,
No External
Fusing Required
Relay Out
Relay Out
N/A
2 Amps at 24 VDC
and 240 VAC
N/A
N/A
2 Amps at 24 VDC
and 240 VAC
2 Amps at 24 VDC
and 240 VAC
95x90x76
95x90x76
95x90x76
95x90x76
95x90x76
95x90x76
Micro Type Restrictions
Number of Discrete
Inputs/Outputs
Output Control Voltage
Relay Maximum Resistive
Load Rating
Dimensions (WxHxD) mm
1.148
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Discrete Expansion Units
The VersaMax Micro’s modular design provides you with remarkable flexibility in a
compact control. The versatile Micro PLC can support up to four Expansion Units of
any mix of discrete or analog.
Product Name
Lifecycle Status
Micro Type Restrictions
Number of Discrete
Inputs/Outputs
Power Voltage
Input Power Supply Rating
24 VDC User Power for Sensors
Input Device Voltage
IC200UEX009
IC200UEX010
IC200UEX215
IC200UEX213
IC200UEX214
14 point (8) 120 VAC In,
(6) Relay Out
(2 outputs at 10 amp
and 4 outputs at 2 amp),
120/240 VAC Powered
14 point (8) 120 VAC In,
(6) 120 VAC Out,
120/240 VAC Powered
28 point (16) 12 VDC In,
(12) 12 VDC Out,
12 VDC Powered
28 point (16) 12 VDC In,
(12) Relay Out,
12 VDC Powered
28 point (16) 24 VDC In,
(12) 24 VDC Out,
24 VDC Powered
Active
Active
Active
Active
Active
N/A
N/A
N/A
N/A
N/A
8 In / 6 Out
8 In / 6 Out
16 In / 12 Out
16 In / 12 Out
16 In / 12 Out
120/240 VAC
120/240 VAC
12 VDC
12 VDC
24 VDC
11 VA
11 VA
8 Watts
8 Watts
5 Watts
200 mA
200 mA
200 mA
200 mA
200 mA
120 VAC
120 VAC
12 VDC
12 VDC
24 VDC
Relay Out
(2 at 10 Amps and
4 at 2 Amps)
120 VAC
12 VDC
Relay Out
24 VDC
Relay Maximum Resistive
Load Rating
2 Amps at 24 VDC
and 240 VAC; 10 Amp at
24 VDC and 240 VAC
N/A
N/A
2 Amps at 24 VDC
and 240 VAC
N/A
Dimensions (WxHxD) mm
95x90x76
95x90x76
150x90x76
150x90x76
150x90x76
Output Control Voltage
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.149
VersaMax Nano and Micro
Programmable Controllers
Discrete Expansion Units
The VersaMax Micro’s modular design provides you with remarkable flexibility in a
compact control. The versatile Micro PLC can support up to four Expansion Units of
any mix of discrete or analog.
IC200UEX222
IC200UEX212
IC200UEX211
IC200UEX209
IC200UEX210
28 point (16) 24 VDC In,
(12) 24 VDC Out
with ESCP,
24 VDC Powered
28 point (16) 24 VDC In,
(12) Relay Out,
24 VDC Powered
28 point (16) 24 VDC In,
(12) Relay Out,
120/240 VAC Powered
28 point (16) 120 VAC In,
(12) Relay Out
(2 outputs at 10 amp
and 10 outputs
at 2 amp),
120/240 VAC Powered
28 point (16) 24 VDC In,
(12) 120 VAC Out,
120/240 VAC Powered
Active
Active
Active
Active
Active
N/A
N/A
N/A
N/A
N/A
16 In / 12 Out
16 In / 12 Out
16 In / 12 Out
16 In / 12 Out
16 In / 12 Out
Power Voltage
24 VDC
24 VDC
120/240 VAC
120/240 VAC
120/240 VAC
Input Power Supply Rating
5 Watts
8 Watts
26 VA
16 VA
16 VA
24 VDC User Power for Sensors
200 mA
200 mA
200 mA
200 mA
200 mA
Product Name
Lifecycle Status
Micro Type Restrictions
Number of Discrete
Inputs/Outputs
Input Device Voltage
Output Control Voltage
Relay Maximum Resistive
Load Rating
Dimensions (WxHxD) mm
1.150
24 VDC
24 VDC
24 VDC
120 VAC
120 VAC
24 VDC ESCP,
Self Healing,
No External
Fusing Required
Relay Out
Relay Out
Relay Out
(2 at 10 Amps
and 10 at 2 Amps)
120 VAC
N/A
2 Amps at 24 VDC
and 240 VAC
2 Amps at 24 VDC
and 240 VAC
2 Amps at 24 VDC and
240 VAC; 10 Amps at
24 VDC and 240 VAC
N/A
150x90x76
150x90x76
150x90x76
150x90x76
150x90x76
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Discrete Expansion Units
The VersaMax Micro’s modular design provides you with remarkable flexibility in a
compact control. The versatile Micro PLC can support up to four Expansion Units of
any mix of discrete or analog.
IC200UEX064
IC200UEX164
IC200UEX264
IC200UEX364
64 point (40) 24 VDC In,
(24) Relay Out,
24 VDC Powered
64 point (40) 24 VDC In,
(24) Relay Out,
120/240 VAC Powered
64 point (40) 24 VDC In,
(24) 24 VDC Source Out,
24 VDC Powered
64 point (40) 24 VDC In,
(24) 24 VDC Sink Out,
24 VDC Powered
Active
Active
Active
Active
Micro 20, 40, 64 Support Only
Micro 20, 40, 64 Support Only
Micro 20, 40, 64 Support Only
Micro 20, 40, 64 Support Only
40 In / 24 Out
40 In / 24 Out
40 In / 24 Out
40 In / 24 Out
24 VDC
120/240 VAC
24 VDC
24 VDC
Input Power Supply Rating
10 Watts
35 VA
10 Watts
10 Watts
24 VDC User Power for Sensors
435 mA
435 mA
435 mA
435 mA
Product Name
Lifecycle Status
Micro Type Restrictions
Number of Discrete
Inputs/Outputs
Power Voltage
Input Device Voltage
24 VDC
24 VDC
24 VDC
24 VDC
Relay Out
Relay Out
24 VDC Sourced
24 VDC Sink
2 Amps at 24 VDC
and 240 VAC
2 Amps at 24 VDC
and 240 VAC
N/A
N/A
190x90x76
190x90x76
190x90x76
190x90x76
Output Control Voltage
Relay Maximum Resistive
Load Rating
Dimensions (WxHxD) mm
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.151
VersaMax Nano and Micro
Programmable Controllers
Analog Expansion Selection Guide
Module Input Power
Input Range
0 to 10V
-10V to +10V
0 to 20mA
4 to 20mA
IC200UEX616
12 VDC
4 in / 2 out
IC200UEX624
24 VDC
4 in
IC200UEX626
24 VDC
4 in / 2 out
4 in / 2 out
IC200UEX636
120/240 VAC
4 in / 2 out
4 in / 2 out
IC200UEX724
24 VDC
4 in
IC200UEX726
24 VDC
4 in / 2 out
IC200UEX734
120/240 VAC
4 in
IC200UEX736
120/240 VAC
4 in / 2 out
IC200UEX824
24 VDC
4 in
4 in
IC200UEX826
24 VDC
4 in / 2 out
4 in / 2 out
Model
1.152
GE Intelligent Platforms Control Systems Solutions
Input Range
RTD Pt 100
Input Range
RTD Pt 100
Input Range
Thermocouple
Type K, J, E, S, T, B, N
Input Range
millivolt
±50mV
±100mV
Output Range
0-10 VDC
0-20 mA
4 in / 2 out
4 in / 2 out
4 in / 2 out
4 in / 2 out
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Analog Expansion Units
The VersaMax Micro analog I/O is versatile and the Micro PLC can support up to four
Analog Expansion Units, allowing you to expand up to 16 inputs and 8 outputs.
IC200UEX624
IC200UEX616
IC200UEX626
IC200UEX636
4 Analog I/O Channels
0 to 10VDC, 4 to 20mA,
24 VDC Powered
6 Analog I/O Channels (4)
0 to 10 VDC, ±10 VDC,
4 to 20 mA, 0 to 20 mA In,
(2) 0 to 10 VDC, 4 to 20 mA,
0 to 20 mA Out,
12 VDC Powered
6 Analog I/O Channels (4)
0 to 10 VDC, ±10 VDC,
4 to 20 mA, 0 to 20 mA In,
(2) 0 to 10 VDC, 4 to 20 mA,
0 to 20 mA Out,
24 VDC Powered
6 Analog I/O Channels (4)
0 to 10 VDC, ±10 VDC,
4 to 20 mA, 0 to 20 mA In,
(2) 0 to 10 VDC, 4 to 20 mA,
0 to 20 mA Out,
120/240 VAC Powered
Active
Active
Active
Active
N/A
N/A
N/A
4 Channels In,
Voltage or Current
4 Channels In /
2 Channels Out,
Voltage or Current
4 Channels In /
2 Channels Out,
Voltage or Current
4 Channels In /
2 Channels Out,
Voltage or Current
Power Voltage
24 VDC
12 VDC
24 VDC
120/240 VAC
Input Power Supply Rating
3 Watts
2.25 Watts
3 Watts
15 VA
24 VDC User Power for Sensors
200 mA
200 mA
200 mA
200 mA
0-10V (10.23V Max);
0-±10V (±10.23V Max);
0-20 mA (20.47 mA Max);
4-20 mA; 12 bit resolution.
0-10V (10.23V Max);
0-±10V (±10.23V Max);
0-20 mA (20.47 mA Max);
4-20 mA; 12 bit resolution.
0-10V (10.23V Max);
0-±10V (±10.23V Max);
0-20 mA (20.47 mA Max);
4-20 mA; 12 bit resolution.
0-10V (10.23V Max);
0-±10V (±10.23V Max);
0-20 mA (20.47 mA Max);
4-20 mA; 12 bit resolution.
N/A
0 to 10 VDC (10.24V max.)
0 to 20 mA (20.5 mA max.)
4 to 20 mA (20.5 mA max.);
12 bit resolution.
0 to 10 VDC (10.24V max.)
0 to 20 mA (20.5 mA max.)
4 to 20 mA (20.5 mA max.);
12 bit resolution.
0 to 10 VDC (10.24V max.)
0 to 20 mA (20.5 mA max.)
4 to 20 mA (20.5 mA max.);
12 bit resolution.
95x90x76
95x90x76
95x90x76
95x90x76
Product Name
Lifecycle Status
Micro Type Restrictions
Number of Analog Inputs/Outputs
Analog Input Ranges
Analog Output Ranges
Dimensions (WxHxD) mm
www.ge-ip.com
N/A
GE Intelligent Platforms Control Systems Solutions 1.153
VersaMax Nano and Micro
Programmable Controllers
Analog Expansion Units
The VersaMax Micro analog I/O is versatile and the Micro PLC can support up to four
Analog Expansion Units, allowing you to expand up to 16 inputs and 8 outputs.
IC200UEX724
IC200UEX734
IC200UEX726
IC200UEX736
4 RTD PT 100 Channels IN,
120/240 VAC Powered
4 RTD PT 100 Channels IN,
24 VDC Powered
4 RTD PT 100 Channels IN,
2 Analog Channels OUT
0 to 10 VDC, 4 to 20 mA,
0 to 20 mA Out,
24 VDC Powered
4 RTD PT 100 Channels IN,
2 Analog Channels OUT
0 to 10 VDC, 4 to 20 mA,
0 to 20 mA Out,
120/240 VAC Powered
Product Name
Lifecycle Status
Active
Active
Active
Active
16 bit supported on
Mircro 20, 40, 64 only
16 bit supported on
Mircro 20, 40, 64 only
16 bit supported on
Mircro 20, 40, 64 only
16 bit supported on
Mircro 20, 40, 64 only
4 Channels RTD In
4 Channels RTD In
4 Channels RTD In /
2 Channels Out,
Voltage or Current
4 Channels RTD In /
2 Channels Out,
Voltage or Current
Power Voltage
24 VDC
120/240 VAC
24 VDC
120/240 VAC
Input Power Supply Rating
3 Watts
15 VA
3 Watts
15 VA
24 VDC User Power for Sensors
200 mA
200 mA
200 mA
200 mA
2- and 3-wire types,
PT 100; 16 bit
2- and 3-wire types,
PT 100; 16 bit
2- and 3-wire types,
PT 100; 16 bit
2- and 3-wire types,
PT 100; 16 bit
N/A
N/A
0 to 10 VDC (10.24V max.)
0 to 20 mA (20.5 mA max.)
4 to 20 mA (20.5 mA max.);
12 bit resolution.
0 to 10 VDC (10.24V max.)
0 to 20 mA (20.5 mA max.)
4 to 20 mA (20.5 mA max.);
12 bit resolution.
95x90x76
95x90x76
95x90x76
95x90x76
Micro Type Restrictions
Number of Analog Inputs/Outputs
Analog Input Ranges
Analog Output Ranges
Dimensions (WxHxD) mm
1.154
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Analog Expansion Units
The VersaMax Micro analog I/O is versatile and the Micro PLC can support up to four
Analog Expansion Units, allowing you to expand up to 16 inputs and 8 outputs.
Product Name
Lifecycle Status
IC200UEX824
IC200UEX826
4 Thermocouple or mV
Input Channels,
24 VDC Powered
4 Thermocouple or mV
Input Channels and
2 Analog Output Channels,
24 VDC Powered
Active
Active
16 bit supported on
Micro 20, 40, 64 only
16 bit supported on
Micro 20, 40, 64 only
4 Channels Thermocouple In
or ±50mV or ±100mV,
24 VDC Power Supply
4 Channels Thermocouple In
or ±50mV or ±100mV and
2 channel analog outputs,
24 VDC Power Supply
Power Voltage
24 VDC
24 VDC
Input Power Supply Rating
3 Watts
3 Watts
Micro Type Restrictions
Number of Analog Inputs/Outputs
24 VDC User Power for Sensors
Analog Input Ranges
200 mA
200 mA
Type K, J, E, S, T, B, N,
±50mV, ±100mV; 12 bit
(16 bit 4th QTR 2009)
Type K, J, E, S, T, B, N,
±50mV, ±100mV; 12 bit
(16 bit 4th QTR 2009)
N/A
0 to 10 VDC (10.24 V max.)
0 to 20 mA (20.5 mA max.)
4 to 20 mA (20.5 mA max.);
12 bit resolution.
95x90x76
95x90x76
Analog Output Ranges
Dimensions (WxHxD) mm
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.155
VersaMax Nano and Micro
Programmable Controllers
Micro Motion Expansion Unit
The Micro Motion expansion module is ideal for either Micro integrated motion control or
standalone motion control over serial or Ethernet networking. The Micro Motion expansion
module is loaded with features and supports a wide range of stepper and servo control.
The module supports a powerful function set, with up to 256 move profiles stored on the
module. Micro Motion module supports the Portable Memory device (removable Flash
device) for easy program storage of the motion moves.
Product Name
Lifecycle Status
Micro Type Restrictions
Number of Axis
Follower Mode
Motion Control Method
Power Voltage
Input Voltages
Output Voltages
Max Speed
Number of Moves Stored
on Unit
Move Types
Position Rollover
Positioning Command Unit
Speed Command Range
Acceleration and
Deceleration
Dwell Time
Acc/Dec Rate
Backlash Correction
Range
Pulse Output Type
Pulse Output Method
Operating Mode
Home Function
Manual (JOG) operation
Feedrate Override Function
High Speed
Input Registration
Motion Module
I/O Assignment
Portable Memory
Module Support
I/O Bus Data Assignement
Dimensions (WxHxD) mm
1.156
IC200UMM002
VersaMax Micro 2 Axis Motion Module
Active
Micro 20, 40, 64 Support Only
2
Axis A can follow B or Axis B can follow A within the module only.
Motion commands can be controlled by Micro 20, 40, 64 or by Modbus
Slave interface (RS-232 IC200USB001 or RS-485 IC200USB002) or Ethernet (IC200UEM001)
24 VDC
line driver (5V) 24 DC
5VDC and 24VDC
500k Pulse/s
IC200UMM102
VersaMax Micro 2 Axis Motion Module
Active
Micro 20, 40, 64 Support Only
2
Axis A can follow B or Axis B can follow A within the module only.
Motion commands can be controlled by Micro 20, 40, 64 or by Modbus
Slave interface (RS-232 IC200USB001 or RS-485 IC200USB002) or
Ethernet (IC200UEM001)
120/240VAC
line driver (5V) 24 DC
5VDC and 24VDC
500k Pulse/s
256 (non-volatile)
256 (non-volatile)
(1) Absolute + Increment method (2) Increment method
Linear, rotation
Pulse, µm, inch, degree, Free-form
6.25 to 500k Pulse/second
(1) Absolute + Increment method (2) Increment method
Linear, rotation
Pulse, µm, inch, degree, Free-form
6.25 to 500k Pulse/second
Liner Acc/Dec, S-shaped Acc/Dec
Liner Acc/Dec, S-shaped Acc/Dec
0 to 65535 ms (1 ms unit)
1 to 50,000,000 (pulse/s2, µm/s2, inch/s2, degree/s2 )
0 to 65,535 ( pulses, µm, inch, degree, Free-form )
Range +2,147,463,647 to –2,147,463,648 pulses
(1) Pulse column [ CW / CCW ] (2) Clock + direction signal
[ CK/direction ]
Line Driver Output
Auto operation and manual operation
Free homing Low-speed homing High-speed homing 1 (OFF edge)
High-speed homing 2 (marker stop)
Manual input signal or pulse output by command
1 to 100% (Speed scale rate)
0 to 65535 ms (1 ms unit)
1 to 50,000,000 (pulse/s2, µm/s2, inch/s2, degree/s2 )
0 to 65,535 ( pulses, µm, inch, degree, degree, Free-form )
Range +2,147,463,647 to –2,147,463,648 pulses
(1) Pulse column [ CW / CCW ] (2) Clock + direction signal
[ CK/direction ]
Line Driver Output
Auto operation and manual operation
Free homing Low-speed homing High-speed homing 1 (OFF edge)
High-speed homing 2 (marker stop)
Manual input signal or pulse output by command
1 to 100% (Speed scale rate)
Differential Input. Supports Windowing
Differential Input. Supports Windowing
Inputs:
A-Channel position data from encoder. (differential)
B-Channel position data from encoder. (differential)
Z-Channel position data from encoder. (differential)
Positioning finish signal from servo driver (COIN)
Home limit switch input
Common for Digital Inputs
Jog Forward
Jog Reverse
Feedrate Override
Estop
Drive OK/Ready
Outputs:
Clockwise Pulse (Pulse) (differential)
Counter Clockwise Pulse (Direction) (differential)
Inputs:
A-Channel position data from encoder. (differential)
B-Channel position data from encoder. (differential)
Z-Channel position data from encoder. (differential)
Positioning finish signal from servo driver (COIN)
Home limit switch input
Common for Digital Inputs
Jog Forward
Jog Reverse
Feedrate Override
Estop
Drive OK/Ready
Outputs:
Clockwise Pulse (Pulse) (differential)
Counter Clockwise Pulse (Direction) (differential)
Yes
Yes
Module requires 8 words in and 8 words out. The module appears
as two expansion units. A maximum of two motion modules allowed
per controller. If one motion module is in system, 2 additional discrete
or analog expansions can be used.
150x90x76
Module requires 8 words in and 8 words out. The module appears
as two expansion units. A maximum of two motion modules allowed
per controller. If one motion module is in system, 2 additional discrete
or analog expansions can be used.
150x90x76
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
DataPanels Operator Interfaces
IC200DTX200
IC200DTX450
GE VersaMax DataPanels are ideal for a broad range of applications ranging from
simple timer/counter/register access to full text message display with numeric keypad.
All VersaMax DataPanels are preprogrammed to connect quickly to a VersaMax Micro
or Nano PLC without user configuration.
IC200DTX850
IC200DTX650
IC200DTX200
IC200DTX450
IC200DTX650
IC200DTX850
Product Name
Operator Interface for
changing timer/counter/
register values. 2x16
character LCD backlight
display and 6 operation keys.
No stored messaging,
PLC stores messages.
Requires IC200CBL550
cable or equivalent.
Operates on 5 VDC @
100 mA from Micro or Nano.
Operator Interface with
up to 200 stored messages.
2x16 character LCD
backlight display and
6 function keys.
Requires IC200CBL555
or equivalent.
Operates on external
24 VDC @ 40 mA.
Operator Interface with
up to 200 stored messages.
4x16 character LCD
backlight display and
8 function keys.
Requires IC200CBL555
cable or equivalent.
Operates on external
24 VDC @ 80 mA.
Operator Interface with
up to 200 stored messages.
4x20 character LCD
backlight display,
8 function keys and
numeric keypad.
Requires IC200CBL555
cable or equivalent.
Operates on external
24 VDC @ 50 mA.
Lifecycle Status
Active
Active
Active
Active
Characters Per Line
16
16
16
20
Function Keys
0
6
8
8
Numeric Keypad
0
0
0
Yes
Memory Size (Number of Messages)
Messages stored in PLC
200 stored in
operator interface
200 stored in
operator interface
200 stored in
operator interface
DataPanel Dimensions (WxHxD) mm
108x60x27
108x60x45
96x96x44
182x101x37
2
2
4
4
LCD Display with Backlight
LCD Display with Backlight
LCD Display with Backlight
LCD Display with Backlight
0°C to +50°C
0°C to +50°C
0°C to +50°C
0°C to +50°C
NEMA 4
NEMA 4
NEMA 4
NEMA 4
None required
DataDesigner
(IC752DDZ000)
DataDesigner
(IC752DDZ000)
DataDesigner
(IC752DDZ000)
Number of Lines
Display Type
Operating Temperature
NEMA Rating
Programming Software
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.157
VersaMax Nano and Micro
Programmable Controllers
Micro 20, Micro 40 and Micro 64 Port 2 Communication Options
The VersaMax Micro 20, Micro 40 and Micro 64 Port 2 is modular by design and enables the
user to select a wide range of communications options. The user can select RS-232, RS-485,
Ethernet or USB. The RS-232 and RS-485 also come with two analog input channels (0 to 10
VDC, 10 bit). Port 2 also supports Memory Module Board that enables the user to download
logic and settings without a PC.
IC200UEM001
IC200USB001
IC200USB002
IC200UUB001
Ethernet module
RS-232 option board with
(2) 0 -10 VDC analog in
RS-485 option board with
(2) 0 -10 VDC analog in
USB option board
(no analog option)
Active
Active
Active
Active
Micro Type Restrictions
Micro 20, 40, 64 Support Only
Micro 20, 40, 64 Support Only
Micro 20, 40, 64 Support Only
Micro 20, 40, 64 Support Only
Connection Type
10/100Mbits port supporting
RJ45 connection
RS-232 (RJ-45)
RS-485 (RJ-45)
USB (Slave Only) version 2.0,
Straight B type
SRTP and
Modbus TCP (server)
SNP, SNP Master, SNP X,
Modbus Master,
Modbus Slave,
Serial Read and Write
SNP, SNP Master, SNP X,
Modbus Master,
Modbus Slave,
Serial Read and Write
SNP, SNP X,
Modbus Slave,
Serial Read
No Analog Support
Two Analog Inputs.
0 to 10 VDC (10 bits)
Two Analog Inputs.
0 to 10 VDC (10 bits)
No Analog Support
Yes
Yes
Yes
Yes
Product Name
Lifecycle Status
Protocol Supported
Analog Support on
Communications Module
Memory Module Board Support
Programming Support
Yes, SRTP only
Yes
Yes
Yes
Programming Software
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
Proficy Machine Edition
Logic Developer 5.0,
Service Pack 3, Hotfix
1.158
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Ethernet Communication Option
The VersaMax SE enables the VersaMax Micro and Nano to easily be connected to an
Ethernet LAN via the VersaMax SE. The user can easily down load, upload and monitor
VersaMax Micro and Nano controllers.
IC200SET001
Product Name
Lifecycle Status
Ethernet Port
Ethernet to Serial Network Module
Active
10/100Mbits port supporting
RJ45 connection
Serial Port
One RS-232 and one RS-485 port
(up to 16 devices supported)
Communications Configurations
Communication configurations
include Ethernet SRTP to SNP or
Modbus TCP to Modbus Slave
Power Voltage
12/24 VDC
Dimensions (WxHxD) mm
36x90x60
Programming Software
Mounting
Power Supply Voltage Range
www.ge-ip.com
VersaPro 2.0 or greater,
Proficy Machine Edition Logic Developer
35 mm DIN-Rail or Panel Mount
12/24 VDC
GE Intelligent Platforms Control Systems Solutions 1.159
VersaMax Nano and Micro
Programmable Controllers
Portable Program Download Device
(PPDD)
The Portable Program Download Device enables the user
to easily upload and download VersaMax Micro 23/28 configuration and logic from/to a USB Memory Stick. Portable
Program Download Device (PPDD) will support commercial
memory stick devices using USB connection. The purpose of
the PPDD is to allow users to store and download their logic
applications and configuration to GE VersaMax Micro 23/28
PLCs without the need of a PC. The PPDD plugs into the 15
pin RS-485 port on the VersaMax Micro 23/28 CPU base
power supply. The RS-485 port provides the power for the
PPDD. VersaMax Micro 23/28 logic and configuration files
can be zipped and easily emailed to remote locations for
VersaMax Micro 23/28 downloads.
There are many advantages of the PPDD such as:
• No PC required to backup applications or download applications
• No expensive travel to perform field upgrades, just email the file to the remote location
• Compatible with commercial off the shelf USB Memory Sticks
• The PPDD can be panel mounted, DIN rail mounted or hand held
• Supports diagnostics to ensure that the CPU is compatible with the application
• OEM Password Protection supported
• Simple to operate, LEDs to show activity, error and status. Push button to start download and selector switch for
direction of download, to the PLC or to the memory stick.
• Designed for the industrial environment UL and CE (not Class 1 Div 2 approved)
PPDD features:
• Slide switch for direction of data storage
• Status and Diagnostic LEDs
LEDs Status
LED On Steady
LED Flashing
Fast Flash (500msec on 500msec off)
Slow Flash (1 sec on 1 sec off)
Error (Red)
Status (Green)
On when there isn’t a Memory Stick attached
On after button has been pushed and name in PLC matches and
when download is complete
Flashing when CPU doesn’t match or
Memory Stick doesn’t have the proper file\
Slow Flash During Download
Flashing if Verify fails
LED Off
1.160
Off during normal conditions with no errors
GE Intelligent Platforms Control Systems Solutions
Fast Flash when CPU type matches but name in PLC doesn’t match
Off prior to button being pushed for download
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
The Portable Program Download Device is simple to use. The example below
demonstrates the four easy steps of downloading an application and emailing
it to a remote location for application upgrade.
Step 1.
Slide PPDD selector toward USB memory stick. Press
PPDD download button. The PPDD will store/verify
the VersaMax Micro application and configuration
onto the USB memory stick.
Step 4.
Place the USB memory stick in the PPDD, slide selector toward
controller. Press PPDD download button. The PPDD will stop
the CPU and download/verify file. The CPU can be placed in
the Run mode via the key switch or cycling power.
Email binary file
Step 2.
Remove the memory stick from the PPDD and connect it
to your PC. Copy the binary file from the memory stick to
your PC and email to remote location.
Step 3.
Remote location takes the binary
file that is in the email and stores
it on a USB memory stick.
Portable Program Download Device
IC690ACC990
www.ge-ip.com
Portable Program Download Device. Supports standard
USB memory devices to store and load VersaMax Micro
23/28 PLC applications without the need of a PC.
GE Intelligent Platforms Control Systems Solutions 1.161
VersaMax Nano and Micro
Programmable Controllers
Accessories
IC200ACC402
Spare Removable Terminal Strips, 10 per pack. (Micro 14, Micro 23 and Micro 28 and all expansion units)
Active
IC200ACC403
Battery for Micro 23 and Micro 28 for data retention (5.2 months minimum @ 70°C and 32.4 months minimum @ 20°C)
Active
IC200ACC404
Spare parts kit. Two terminal strips and four plastic doors and four covers for Micro 14, Micro 23 and Micro 28.
Active
IC200ACC414
Long Term Battery for Micro 23, Micro 28 and Micro 64 (19 months minimum @ 70°C and 121 months minimum @ 20°C)
Active
IC200ACC415
RS-232 to RS-485 Converter requires IC200CBL500 or equivalent.
Active
IC200ACC451
Simulator for VersaMax Micro 14, Micro 23 and Micro 28. (8 Inputs)
Active
IC200UMB001
Flash Memory Board for program download and compatible with Micro 64 (128Kbytes)
Active
External Power Supplies
IC690PWR024
24 VDC, 5 Amp Output Power and 120/230 VAC Input Power Power Supply
Active
IC690PWR124
24 VDC, 10 Amp Output Power and 120/230 VAC Input Power Power Supply
Active
Programming and Trouble Shooting Tools
IC646MPM101
Proficy Logic Developer - PLC Nano/Micro, Programming Cable (No Upgrades included)
Active
IC752DDZ000
VersaMax DP Operator Interface DataDesigner editor
Active
Cables
(0.1 meter cable, IC200CBL501, is included in every expansion base package)
IC200CBL500
Programming cable (RJ-45 to DB-9 pin) RS-232. 3 Meters.
Active
IC200CBL501
I/O Expansion cable, 0.1 meter long (Qty 5)
Active
IC200CBL505
I/O Expansion cable, 0.5 meter long
Active
IC200CBL510
I/O Expansion cable, 1 meter long
Active
1.162
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Starter Kits
IC200TBX010
Tool box, Nano 10 and software. Includes (IC200NDR001) 24 VDC In/Relay Out, 24 VDC powered (requires an external 24 VDC Supply) with software,
manuals and cables (IC646MPH101)
Active
IC200TBX110
Tool box, Nano 10, operator interface and software. Includes (IC200NDR001) 24 VDC In/Relay Out, 24 VDC powered (requires an external 24 VDC Supply),
VersaMax DataPanel DP45 with programming software and cables, (IC640VPS00, IC752DDZ000, IC200CBL555)
Active
IC200TBX210
Tool box, Nano 10, Ethernet interface and software. Includes (IC200NDR001) 24 VDC In/Relay Out, 24 VDC powered (requires an external 24 VDC Supply),
VersaMax SE (IC200SET001) with all software, cables (IC646MPH101) and manuals.
Active
IC200TBX014
Tool box, Micro 14 and software. Includes (IC200UDR001) 24 VDC In/Relay Out, AC Power Supply with software, manuals and cables (IC646MPH101)
Active
IC200TBX114
Tool box, Micro 14, operator interface and software. Includes (IC200UDR001) 24 VDC In/Relay Out, AC Power Supply, VersaMax DataPanel DP45
with programming software and cables, (IC640VPS00, IC752DDZ000, IC200CBL555)
Active
IC200TBX214
Tool box, Micro 14, Ethernet interface and software. Includes (IC200UDR001) 24 VDC In/Relay Out, requires 120 VAC power, VersaMax SE
(IC200SET001) with all software, cables (IC646MPH101) and manuals.
Active
IC200TBX023
Tool box, Micro 23 and software. Includes (IC200UAL006) DC In/Relay Out, 2 analog In, 1 analog out, AC Power Supply with software, manuals
and cables (IC646MPH101)
Active
IC200TBX123
Tool box, Micro 23, operator interface and software. Includes (IC200UAL006) 24 VDC In/Relay Out, 2 Analog In/1 Analog out, AC P/S, VersaMax
DataPanel DP45 with programming software and cables, (IC640VPS00, IC752DDZ000, IC200CBL555)
Active
IC200TBX223
Tool box, Micro 23, Ethernet interface and software. Includes (IC200UAL006) 24 VDC In/Relay Out, requires 120 VAC Power, VersaMax SE
(IC200SET001) with all software, cables (IC646MPH101) and manuals.
Active
IC200TBX028
Tool box, Micro 28 and software. Includes (IC200UDR005) 24 VDC In/Relay Out, AC Power Supply with software, manuals and cables (IC646MPH101)
Active
IC200TBX128
Tool box, Micro 28, operator interface and software. Includes (IC200UDR005) 24 VDC In/Relay Out, AC P/S, VersaMax DataPanel DP45 with
programming software and cables, (IC640VPS00, IC752DDZ000, IC200CBL555)
Active
IC200TBX228
Tool box, Micro 28, Ethernet interface and software. Includes (IC200UDR005) 24 VDC In/Relay Out, requires 120 VAC Power, VersaMax SE (IC200SET001)
with all software, cables (IC646MPH101) and manuals.
Active
IC200TBX020
Tool box, Micro 20 and software. Includes (IC200UDD020) 24VDC In/24VDC Out, DC Power Supply, (IC200USB001) RS-232 option board with
(2) 0 -10VDC analog in with Proficy software, manuals and cables (IC646MPM101)
Active
IC200TBX120
Tool box, Micro 20 and software. Includes (IC200UDR120) 24VDC In/Relay Out, AC Power Supply, (IC200USB001) RS-232 option board with
(2)0 -10VDC analog in with Proficy software, manuals and cables (IC646MPM101)
Active
IC200TBX220
Tool box, Micro 20, operator interface and software. Includes (IC200UDD020) 24VDC In/24VDC Out, DC Power Supply, (IC200USB001) RS-232
option board with (2) 0 -10VDC analog in with VersaMax DataPanel DP45 with Proficy programming software and cables, (IC646MPM101,
IC752DDZ000, IC200CBL555)
Active
IC200TBX320
Tool box, Micro 20, operator interface and software. Includes (IC200UDR120) 24VDC In/Relay Out, AC Power Supply, (IC200USB001) RS-232
option board with (2) 0 -10VDC analog in with VersaMax DataPanel DP45 with Proficy Logic Developer programming software and cables,
(IC646MPM101, IC752DDZ000, IC200CBL555)
Active
IC200TBX520
Tool box, Micro 20, QuickPanel color touch screen and software. Includes (IC200UDR164) 24VDC In/Relay Out, AC Power Supply, (IC200UEM001)
Ethernet option board, QuickPanel Display (IC754VSI06STD) with Proficy software, manuals and cables (BC646MBL001)
Active
IC200TBX040
Tool box, Micro 40 and software. Includes (IC200UDD040) 24VDC In/24VDC Out, DC Power Supply, (IC200USB001) RS-232 option board with
(2) 0 -10VDC analog in with Proficy software, manuals and cables (IC646MPM101)
Active
IC200TBX140
Tool box, Micro 40 and software. Includes (IC200UDR140) 24VDC In/Relay Out, AC Power Supply, (IC200USB001) RS-232 option board with
(2) 0 -10VDC analog in with Proficy software, manuals and cables (IC646MPM101)
Active
IC200TBX240
Tool box, Micro 40, operator interface and software. Includes (IC200UDD040) 24VDC In/24VDC Out, DC Power Supply, (IC200USB001) RS-232
option board with (2) 0 -10VDC analog in with VersaMax DataPanel DP45 with Proficy programming software and cables, (IC646MPM101,
IC752DDZ000, IC200CBL555)
Active
IC200TBX340
Tool box, Micro 40, operator interface and software. Includes (IC200UDR140) 24VDC In/Relay Out, AC Power Supply, (IC200USB001) RS-232 option
board with (2) 0 -10VDC analog in with VersaMax DataPanel DP45 with Proficy Logic Developer programming software and cables, (IC646MPM101,
IC752DDZ000, IC200CBL555)
Active
IC200TBX540
Tool box, Micro 40, QuickPanel color touch screen and software. Includes (IC200UDR140) 24VDC In/Relay Out, AC Power Supply, (IC200UEM001)
Ethernet option board, QuickPanel Display (IC754VSI06STD) with Proficy software, manuals and cables (BC646MBL001)
Active
IC200TBX064
Tool box, Micro 64 and software. Includes (IC200UDD064) 24 VDC In/24 VDC Out, DC Power Supply, (IC200USB001) RS-232 option board with
(2) 0 -10 VDC analog in with Proficy software, manuals and cables (IC646MPM101)
Active
IC200TBX164
Tool box, Micro 64 and software. Includes (IC200UDR164) 24 VDC In/Relay Out, AC Power Supply, (IC200USB001) RS-232 option board with
(2) 0 -10 VDC analog in with Proficy software, manuals and cables (IC646MPM101)
Active
IC200TBX264
Tool box, Micro 64, operator interface and software. Includes (IC200UDD064) 24 VDC In/24 VDC Out, DC Power Supply, (IC200USB001) RS-232
option board with (2) 0 -10 VDC analog in with VersaMax DataPanel DP45 with Proficy programming software and cables, (IC646MPM101,
IC752DDZ000, IC200CBL555)
Active
IC200TBX364
Tool box, Micro 64, operator interface and software. Includes (IC200UDR164) 24 VDC In/Relay Out, AC Power Supply, (IC200USB001) RS-232 option
board with (2) 0 -10 VDC analog in with VersaMax DataPanel DP45 with Proficy Logic Developer programming software and cables, (IC646MPM101,
IC752DDZ000, IC200CBL555)
Active
IC200TBX564
Tool box, Micro 64, QuickPanel color touch screen and software. Includes (IC200UDR164) 24 VDC In/Relay Out, AC Power Supply, (IC200UEM001)
Ethernet option board, QuickPanel Display (IC754VSI06STD) with Proficy software, manuals and cables (BC646MBL001)
Active
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.163
VersaMax Nano and Micro
Programmable Controllers
Configuration Guidelines
Examples of Typical Application
Configuration for Nano 10 (Applications needing less than 6 (24 VDC) inputs and 4 relay outputs)
Qty
Part Number
Description
1
IC200NDR001
10 point (6) 24 VDC In, (4) Relay Out, 24 VDC Powered
1
BC646MPM101
Proficy Logic Developer - PLC Nano/Micro, Programming Cable included and Proficy
GlobalCare Complete (Upgrades included for 15 months of upgrades)
Options to consider
1
IC200ACC450
Simulator for VersaMax Nano 10. (6 Inputs)
1
IC690PWR024
24 VDC, 5 Amp Output Power and 120/230 VAC Input Power Power Supply
Configuration for Micro 14 (Example Application needing 12 (24 VDC) discrete inputs, 6 relay outputs and 3 Analog inputs with 24 VDC power)
Qty
Part Number
Description
1
IC200UDR002
14 point (8) 24 VDC In, (6) Relay Out, 24 VDC Powered
1
IC200UEI008
8 point 24 VDC In, 24 VDC Powered
1
IC200UEX626
6 Analog I/O Channels (4) 0 to 10 VDC, ±10 VDC, 4 to 20 mA, 0 to 20 mA In, (2) 0 to 10
VDC, 4 to 20 mA, 0 to 20 mA Out, 24 VDC Powered
1
BC646MPM101
Proficy Logic Developer - PLC Nano/Micro, Programming Cable included and Proficy
GlobalCare Complete (Upgrades included for 15 months of upgrades)
1
IC200UDR010
28 point (16) 24 VDC In, (12) Relay Out, 24 VDC Powered - advantage is two serial ports,
Real Time clock and more data memory.
Options to consider
1
IC200ACC451
Simulator for VersaMax Micro 14, Micro 23 and Micro 28. (8 Inputs)
1
IC690PWR024
24 VDC, 5 Amp Output Power and 120/230 VAC Input Power Power Supply
1
IC200DTX650
Operator Interface with up to 200 stored messages. 4x16 character LCD backlight
display and 8 function keys. Requires IC200CBL550 cable or equivalent. Operates on
external 24 VDC @ 80 mA.
Configuration for Micro 28 (Example Application needing 22 (24 VDC) discrete inputs, 16 outputs [Ten Relay and Six 24 VDC], 2 RTD inputs,
1 Analog output using AC power. Also requires Display with keypad)
Qty
Part Number
Description
1
IC200UDR005
28 point; (16) 24 VDC In, (11) Relay Out, (1) 24 VDC Out, 120/240 VAC Powered.
1
IC200ACC403
Battery for Micro 23 and Micro 28 for data retention
1
IC200UEX014
14 point (8) 24 VDC In, (6) 24 VDC Out, 24 VDC Powered
1
IC200UEX736
4 RTD PT 100 Channels IN, 2 Analog Channels OUT 0 to 10 VDC, 4 to 20 mA, 0 to 20 mA
Out, 120/240 VAC Powered
1
BC646MPM101
Proficy Logic Developer - PLC Nano/Micro, Programming Cable included and Proficy
GlobalCare Complete (Upgrades included for 15 months of upgrades)
1
IC200DTX850
Operator Interface with up to 200 stored messages. 4x20 character LCD backlight display, 8 function keys and numeric keypad. Requires IC200CBL550 cable or equivalent.
Operates on external 24 VDC @ 50 mA.
1
IC752DDZ000
VersaMax DP Operator Interface DataDesigner editor
Options to consider
1.164
1
IC200ACC451
Simulator for VersaMax Micro 14, Micro 23 and Micro 28. (8 Inputs)
1
IC690PWR024
24 VDC, 5 Amp Output Power and 120/230 VAC Input Power Power Supply
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Configuration for Micro 644 (Example Application needing 45 (24VDC) discrete inputs, 32 outputs (Twelve Relay and Twenty 24VDC), 2 Servo motors.
Application also requires Color Touch Graphic Display
Qty
Part Number
Description
1
IC200UDD064
Micro 64; (40) 24 VDC In, (24) 24 VDC Source Out 0.7 amps with ESCP protection,
24 VDC Power Supply.
1
IC200ACC414
Long Term Battery for Micro 23, Micro 28 and Micro 64
1
IC200UEX211
28 point (16) 24 VDC In, (12) Relay Out, 120/240 VAC Power Supply
1
IC200UEM001
Ethernet Module
1
IC200UMM002
2 Axis Motion Module
1
IC800VMM10LBKSE25
VersaMotion 1000 Watt Motor with brake
1
IC800VMA102
Servo Amplifier, 1000 Watts, 220VAC
1
IC800VMCB1030
Brake and Power Cable for 1000 Watt Servo Motor and brake, 3 meters
1
IC800VMCE1030
Encoder Cable for 1000 Watt and greater, 3 meters
1
IC800VMTBC005
I/O terminal block and cable .5 meters
1
IC800VMCS030
Communications cable and servo driver to PC, 3 meters
1
IC754VSI06STD
QuickPanel View Intermediate 6 inch STN Touch
1
BC646MBL001
Machine Edition Lite Development Suite with Proficy GlobalCare Complete. Includes
View Development for QuickPanel and LD-PLC Nano/Micro with 15 months of Proficy
GlobalCare which is renewable on an annual basis.
1
IC200CBL500
Programming cable (RJ-45 to DB-9 pin) RS-232. 3 Meters.
Options to consider
www.ge-ip.com
1
IC200UMB001
Flash Memory Board for program download and compatible with Micro 64 (128Kbytes)
1
IC690PWR124
24VDC, 10 Amp Output Power and 120/230VAC Input Power Power Supply
GE Intelligent Platforms Control Systems Solutions 1.165
VersaMax Nano and Micro
Programmable Controllers
VersaMotion
VersaMotion is a family of servo
motors and amplifiers. The
VersaMotion amplifier supports high
speed pulse and direction commands
from the controllers. The VersaMotion
servo drive is simple to use and maintain with the added diagnostics and
removable terminal strips. Amplifier
setup can be accomplished using the
VersaMotion software included with
Proficy Machine Edition or using the
convenient front panel ­keypad.
Key Features:
• Versatile analog or pulse command
interface
• Position/Speed/Torque modes
• Dual control modes
• Internal single-axis position control
Built-in Functions:
• Electronic gearing
• Point-to-Point single axis position
control
• External JOG function
• Speed/Torque limit operation
• Built-in keypad/display for setup and
diagnostics
• Motor settling time below 1 ms
• Low speed stability and
performance: less than 0.5% error
at 1 RPM
• 10msec acceleration time from running without load -/+ 3000 RPM
• High speed inertia corrections
(16 levels of system stiffness and
­responsiveness)
1.166
• Simple stand-alone positioning
­function with 8 internal stored
­position settings
• Move to Home function
• Position Teaching capability
• Incremental encoder feedback
(2500 ppr)
• User-definable
Acceleration/Deceleration with jerk
limiting (s-curve)
• Feed step control function
• Modbus Slave serial port (RS-485/
RS-422) for reading and writing
parameters from Machine Edition
GE Intelligent Platforms Control Systems Solutions
Machine Edition VersaMotion
Set-up Features:
• Configuration Parameter Editor
(clear, read, write functions) and
i­nitial configuration wizard
• Calculation tools to determine
p
­ roper conversion from encoder
counts to desired user programming
units
• Three channel digital oscilloscope to
display and record drive status
on-line
• Alarm history and status monitor
diagnostic screens
• Digital I/O set-up and monitoring
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Servo Amplifier Part Number Sequence
IC800VMA
04
2
Input Voltage
2– 220VAC Single Phase
Rated Power
01– 100 Watts
02– 200 Watts
04– 400 Watts
07– 750 Watts
10– 1000 Watts
20– 2000 Watts
30–­3000 Watts
Example: IC800VMA042 is a 400 watt 220VAC servo amplifier
Amplifiers Technical Data
Permissible Frequency Fluctuation
50 / 60 Hz +/-5%
Resolution/Quadrature Feedback Counts
2500 ppr /10000 cpr
Control Modes
Position/Velocity/Torque
Dynamic Brake
Built-in
Position Control Mode:
Maximum Input Pulse Frequency
500KPPS (Line Driver) / Maximum 200KPPS (Open Collector)
Pulse Type
Pulse/Direction;
Command Source
External pulse train/ Internal parameters
Torque Limit Operation
Yes
Feed Forward Compensation
Yes
CW/CCW;
A/B Phase
Analog Commands: Voltage Range
0 to +/-10 VDC
Torque and Velocity Control Mode: Command Source
External analog signal / Internal parameters
Speed Control Range
1:5000
Speed Control Frequency Response
Maximum 450 Hz
Torque Control Mode Permissible Time for Overload
8 seconds under 200% rated output
Communications Interface
RS-232 / RS-485 /RS-422
Environmental Altitude
Altitude 1000 meters above sea level or lower
Environmental Operating Temperature
0 to 55°C (Forced cooling for operation above 55°C)
Environmental Storage Temperature
-20°C to 65°C
Environmental Humidity
0 to 90% (Non condensing)
Vibration
<20 Hz: 9.8 m/sec/sec (1G); 20 to 50 Hz: 5.88 m/sec/sec (0.6 G)
Standards
IEC/EN 61800-5-1, UL 508C, TUV, C-tick
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.167
VersaMax Nano and Micro
Programmable Controllers
Amplifiers
The VersaMotion family of servo amplifiers offers a cost effective solution for a broad range
of motion applications. These versatile amplifiers support simple stand-alone positioning
capability using up to 8 stored motion profiles or can be connected to any motion controller
using an analog or pulse command interface. A built-in touchpad and display provides
convenient access to configuration parameters and system information. The serial interface
supports multi-drop system configurations and Modbus communication protocol.
IC800VMA012
IC800VMA022
IC800VMA042
IC800VMA072
Product Name
VersaMotion Amplifier
VersaMotion Amplifier
VersaMotion Amplifier
VersaMotion Amplifier
Lifecycle Status
Active
Active
Active
Active
Rated Output Power
100W
200W
400W
750W
Voltage/Frequency
Three-phase or
Single-phase 220VAC
50/60 Hz
Three-phase or
Single-phase 220VAC
50/60 Hz
Three-phase or
Single-phase 220VAC
50/60 Hz
Three-phase or
Single-phase 220VAC
50/60 Hz
Permissible Voltage
Fluctuation
Three-phase: 170 ~ 255VAC
Single-phase: 200 ~ 255VAC
Three-phase: 170 ~ 255VAC
Single-phase: 200 ~ 255VAC
Three-phase: 170 ~ 255VAC
Single-phase: 200 ~ 255VAC
Three-phase: 170 ~ 255VAC
Single-phase: 200 ~ 255VAC
Convection
Convection
Convection
Fan Cooling
Gear Ratio = N/M where N
1~32767, M: 1:32767
(1/50<N/M<200)
Gear Ratio = N/M where N:
1~32767, M: 1:32767
(1/50<N/M<200)
Gear Ratio = N/M where N:
1~32767, M: 1:32767
(1/50<N/M<200)
Gear Ratio = N/M where N:
1~32767, M: 1:32767 (1/50<N/
M<200)
Cooling System
Electronic Gear Ratio
IC800VMA102
IC800VMA202
IC800VMA302
Product Name
VersaMotion Amplifier
VersaMotion Amplifier
VersaMotion Amplifier
Lifecycle Status
Active
Active
Active
Rated Output Power
1KW
2KW
3KW
Voltage/Frequency
Three-phase or
Single-phase 220VAC
50/60 Hz
Three-phase 220VAC
50/60 Hz
Three-phase 220VAC
50/60 Hz
Three-phase: 170 ~ 255VAC
Single-phase: 200 ~ 255VAC
Three-phase: 170 ~ 255VAC
Three-phase: 170 ~ 255VAC
Fan Cooling
Fan Cooling
Fan Cooling
Gear Ratio = N/M where N
1~32767, M: 1:32767
(1/50<N/M<200)
Gear Ratio = N/M where N:
1~32767, M: 1:32767
(1/50<N/M<200)
Electronic gear N/M multiple N:
1~32767, M: 1:32767
(1/50<N/M<200)
Permissible Voltage Fluctuation
Cooling System
Electronic Gear Ratio
1.168
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Servo Motor Part Number Sequence
IC800VMM
30
Rated Power
01– 100 Watts
02– 200 Watts
04– 400 Watts
07– 750 Watts
10– 1000 Watts
20– 2000 Watts
30–­3000 Watts
M
B
K
S
E25
Feedback
E25– 2500 ppr incremental encoder
Shaft Seal
S– With seal
Key
K– With shaft key
Brake
N– No brake
B– With brake (except 100 Watt Motor)
Inertia
L– Low Inertia
M– Medium Inertia (1Kw, 2Kw and 3Kw models only)
Example: IC800VMM30MBKSE25 is a 3000 watt medium Inertia motor with 2500 ppr encoder, brake, keyway and shaft seal.
Motors Technical Data
Insulation Class
Class B
Insulation Resistance
>100M ohm, 500 VDC
Insulation Strength
1500 VAC, 50Hz, 60 seconds
Vibration Grade (um)
15
Brake Power (VDC)
24
Operating Temperature (C)
0°~40°
Storage Temperature (C)
-10°~80°
Humidity
20~90%RH (non condensing)
Vibration
2.5G
IP Rating
IP65 (except shaft and connector)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.169
VersaMax Nano and Micro
Programmable Controllers
Motors
The VersaMotion family of servo motors offers high servo performance in a compact
­package. The motors range from 100 W to 3 kW with continuous torque ratings from
0.3 Nm to 14.3 Nm. All motors have metric mounting configurations and include a shaft
key and oil seal. For vertical axes or applications that need to hold position during power
loss motors with 24 VDC holding brakes are available. Motors are matched with the
VersaMotion amplifiers.
IC800VMM01L
IC800VMM02L
IC800VMM04L
IC800VMM07L
Product Name
VersaMotion
100 Watt
VersaMotion
200 Watt
VersaMotion
400 Watt
VersaMotion
750 Watt
Lifecycle Status
Active
Active
Active
Active
Rated Output (kW)
0.1
0.2
0.4
0.75
Rated Torque (Nm)
0.32
0.64
1.27
2.39
Maximum Torque (Nm)
0.96
1.92
3.82
7.16
Rated Speed (RPM)
3000
3000
3000
3000
Maximum Speed (RPM)
5000
5000
5000
5000
Rated Current (Amps)
0.9
1.55
2.6
5.1
Maximum Current (Amps)
2.7
4.65
7.8
15.3
Rotor Moment of Inertia (Kg.m2 x 10-4)
0.037
0.177
0.277
1.13
Mechanical Time Constant (msec)
0.75
0.8
0.53
0.63
Torque Constant - KT (Nm)
0.36
0.41
0.49
0.47
Voltage Constant - KE (mV/rmp)
13.6
16
17.4
17.2
Armature Resistance (Ohm)
9.3
2.79
1.55
0.42
Armature Inductance (mH)
24
10.84
6.84
3.53
Electrical Time Constant (msec)
2.58
3.89
4.43
8.37
Maximum Radial Shaft Load (Newton)
78.4
196
196
245
Maximum Thrust Shaft Load (Newton)
39.2
68
68
98
1.170
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Motors
The VersaMotion family of servo motors offers high servo performance in a compact
­package. The motors range from 100 W to 3 kW with continuous torque ratings from
0.3 Nm to 14.3 Nm. All motors have metric mounting configurations and include a shaft
key and oil seal. For vertical axes or applications that need to hold position during power
loss motors with 24 VDC holding brakes are available. Motors are matched with the
VersaMotion amplifiers.
IC800VMM10L
IC800VMM10M
IC800VMM20L
IC800VMM20M
IC800VMM30M
Product Name
VersaMotion
1000 Watt
VersaMotion
1000 Watt
VersaMotion
2000 Watt
VersaMotion
2000 Watt
VersaMotion
3000
Lifecycle Status
Active
Active
Active
Active
Active
WattRated Output (kW)
1.0
1.0
2.0
2.0
3.0
Rated Torque (Nm)
3.18
4.77
6.37
9.55
14.32
Maximum Torque (Nm)
9.54
14.32
19.11
28.66
42.96
Rated Speed (RPM)
3000
2000
3000
2000
2000
Maximum Speed (RPM)
5000
3000
5000
3000
3000
Rated Current (Amps)
7.3
5.6
11.3
11.0
16.1
Maximum Current (Amps)
21.9
24.9
33.9
33.0
48.3
Rotor Moment of Inertia (Kg.m2 x 10-4)
2.65
9.14
4.45
15.88
55
Mechanical Time Constant (msec)
0.74
1.64
0.66
1.05
1.06
Torque Constant - KT (Nm/A)
0.44
0.85
0.53
0.87
0.89
Voltage Constant - KE (mV/rpm)
16.8
31.9
19.2
31.8
32
Armature Resistance (Ohm)
0.20
0.465
0.14
0.174
0.052
Armature Inductance (mH)
2.0
5.99
1.53
2.76
1.38
10.26
12.88
10.63
15.86
26.39
Maximum Radial Shaft Load (Newton)
490
490
490
490
1470
Maximum Thrust Shaft Load (Newton)
98
98
98
98
490
IC800VMA102
IC800VMA102
IC800VMA202
IC800VMA202­
IC800VMA302
Electrical Time Constant (msec)
Amplifier Model
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.171
VersaMax Nano and Micro
Programmable Controllers
VersaMotion Accessories
Amplifier Connectors
Motor Connectors
IC800VMACONCN1
CN1 I/O Connector
Active
IC800VMMCONP001
IC800VMACONCN2
CN2 Encoder Connector
Active
IC800VMMCONP002
IC800VMACONCN3
CN3 Communication Connector
Active
IC800VMACONACP
AC Power Connector (100W to 1kW models only)
Active
Motor Power Connector (100W to 1kW
models only)
External Braking Resistor Connector
(100W to 1kW models only)
Active
IC800VMACONMTRP
IC800VMADBR001
Active
IC800VMMCONP003
IC800VMMCONP004
IC800VMMCONE001
IC800VMMCONE002
Motor Power Connector for 100 Watt to
750 Watt motors without brake
Motor Power Connector for 100 Watt to
750 Watt motors with brake
Motor Power Connector for 1000 Watt or
2000 Watt motors with or without brake
Motor Power Connector for 3000 Watt
motors with or without brake
Encoder Connector for 100 Watt to
750 Watt motors
Encoder Connector for 1000 Watt and
larger motors
Active
Active
Active
Active
Active
Active
Motor Power Cables
IC800VMCP030
Power Cable for 100 Watt to 750 Watt servo motor without brake, 3 m (9.8 feet)
Active
IC800VMCP050
Power Cable for 100 Watt to 750 Watt servo motor without brake, 5 m (16.4 feet)
Active
IC800VMCP100
Power Cable for 100 Watt to 750 Watt servo motor without brake, 10 m (32.8 feet)
Active
IC800VMCP200
Power Cable for 100 Watt to 750 Watt servo motor without brake, 20 m (65.7 feet)
Active
IC800VMCP1030
Power Cable for 1000 Watt servo motor without brake, 3 m (9.8 feet)
Active
IC800VMCP1050
Power Cable for 1000 Watt servo motor without brake, 5 m (16.4 feet)
Active
IC800VMCP1100
Power Cable for 1000 Watt servo motor without brake, 10 m (32.8 feet)
Active
IC800VMCP1200
Power Cable for 1000 Watt servo motor without brake, 20 m (65.7 feet)
Active
IC800VMCP2030
Power Cable for 2000 Watt servo motor without brake, 3 m (9.8 feet)
Active
IC800VMCP2050
Power Cable for 2000 Watt servo motor without brake, 5 m (16.4 feet)
Active
IC800VMCP2100
Power Cable for 2000 Watt servo motor without brake, 10 m (32.8 feet)
Active
IC800VMCP2200
Power Cable for 2000 Watt servo motor without brake, 20 m (65.7 feet)
Active
IC800VMCP3030
Power Cable for 3000 Watt servo motor without brake, 3 m (9.8 feet)
Active
IC800VMCP3050
Power Cable for 3000 Watt servo motor without brake, 5 m (16.4 feet)
Active
IC800VMCP3100
Power Cable for 3000 Watt servo motor without brake, 10 m (32.8 feet)
Active
IC800VMCP3200
Power Cable for 3000 Watt servo motor without brake, 20 m (65.7 feet)
Active
Brake and Motor Power Cables
IC800VMCB030
Brake and Motor Power Cable for 200 Watt to 750 Watt servo motor with brake, 3 m (9.8 feet)
Active
IC800VMCB050
Brake and Motor Power Cable for 200 Watt to 750 Watt servo motor with brake, 5 m (16.4 feet)
Active
IC800VMCB100
Brake and Motor Power Cable for 200 Watt to 750 Watt servo motor with brake, 10 m (32.8 feet)
Active
IC800VMCB200
Brake and Motor Power Cable for 200 Watt to 750 Watt servo motor with brake, 20 m (65.7 feet)
Active
IC800VMCB1030
Brake and Motor Power Cable for 1000 Watt servo motor with brake, 3 m (9.8 feet)
Active
IC800VMCB1050
Brake and Motor Power Cable for 1000 Watt servo motor with brake, 5 m (16.4 feet)
Active
IC800VMCB1100
Brake and Motor Power Cable for 1000 Watt servo motor with brake, 10 m (32.8 feet)
Active
IC800VMCB1200
Brake and Motor Power Cable for 1000 Watt servo motor with brake, 20 m (65.7 feet)
Active
IC800VMCB2030
Brake and Motor Power Cable for 2000 Watt servo motor with brake, 3 m (9.8 feet)
Active
IC800VMCB2050
Brake and Motor Power Cable for 2000 Watt servo motor with brake, 5 m (16.4 feet)
Active
IC800VMCB2100
Brake and Motor Power Cable for 2000 Watt servo motor with brake, 10 m (32.8 feet)
Active
IC800VMCB2200
Brake and Motor Power Cable for 2000 Watt servo motor with brake, 20 m (65.7 feet)
Active
IC800VMCB3030
Brake and Motor Power Cable for 3000 Watt servo motor with brake, 3 m (9.8 feet)
Active
IC800VMCB3050
Brake and Motor Power Cable for 3000 Watt servo motor with brake, 5 m (16.4 feet)
Active
IC800VMCB3100
Brake and Motor Power Cable for 3000 Watt servo motor with brake, 10 m (32.8 feet)
Active
IC800VMCB3200
Brake and Motor Power Cable for 3000 Watt servo motor with brake, 20 m (65.7 feet)
Active
1.172
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
VersaMax Nano and Micro
Encoder Cables
IC800VMCE030
Encoder Cable for 100 to 750 Watt, 3 m (9.8 feet)
Active
IC800VMCE050
Encoder Cable for 100 to 750 Watt, 5 m (16.4 feet)
Active
IC800VMCE100
Encoder Cable for 100 to 750 Watt, 10 m (32.8 feet)
Active
IC800VMCE200
Encoder Cable for 100 to 750 Watt, 20 m (65.7 feet)
Active
IC800VMCE1030
Encoder Cable for 1000 Watt and greater, 3 m (9.8 feet)
Active
IC800VMCE1050
Encoder Cable for 1000 watt and greater, 5 m (16.4 feet)
Active
IC800VMCE1100
Encoder Cable for 1000 watt and greater, 10 m (32.8 feet)
Active
IC800VMCE1200
Encoder Cable for 1000 watt and greater, 20 m (65.7 feet)
Active
I/O Terminal Block
IC800VMTBC005
I/O Terminal Block Breakout Board and 0.5 m (1.6 feet) Cable
Active
External Braking Resistors
IC800VMBR040
40 Ohm, 400 Watt External Braking (Regeneration) Resistor
Active
IC800VMBR020
20 Ohm, 1000 Watt External Braking (Regeneration) Resistor
Active
Communications and I/O Interface Cables
IC800VMCS030
Communications Cable from servo amplifier to PC, 3 m (9.8 feet)
Active
IC800VMCI010
Flying lead I/O interface cable, 1 meter
Active
IC800VMCI030
Flying lead I/O interface cable, 3 meter
Active
Software Configuration Tool
IC646MPM101
Proficy Logic Developer - PLC Nano/Micro and VersaMotion, Programming Cable (No Upgrades included)
Active
BC646MPM101
Proficy Logic Developer - PLC Nano/Micro and VersaMotion, Programming Cable (Includes 15 months of upgrades)
Active
Examples of Typical Application using a VersaMax Micro
Application: 1000 Watt Low Inertia Motor with Brake and micro controller (14) 24VDC inputs and (10) Relay outputs (AC power supply). In addition the application needs Ethernet LAN
to 6 inch color STN touch display.
Qty
Part Number
Description
Controller, I/O and Display
1
IC200UDR120
VersaMax Micro 20 point PLC, (12) 24VDC In, (8) Relay Out, 120/240VAC Power Supply
1
IC200UEC208
VersaMax 8 point expansion unit, (4) 24VDC inputs, (4) Relay Outputs and 24VDC Power Supply (The VersaMax Micro 20
controller 24VDC user power supply can support the expansion module)
1
IC200UMM102
VersaMax Micro Motion 2 Axis Servo Module, 120/240VAC Supply
1
IC200UEM001
VersaMax Micro 10/100Mbits Ethernet Module
1
IC754VSI06STD
QuickPanel View Intermediate 6 inch STN Touch
Servo Amplifier and Motor
1
IC800VMM10LBKSE25
VersaMotion 1000 Watt Low Inertia Servo Motor with brake. Motor has keyway and oil seal
1
IC800VMA102
Servo Amplifier, 1000 Watts, 220VAC
1
IC800VMCB1030
Brake and Power Cable for 1000 Watt Servo Motor with brake, 3 m (9.8 feet)
1
IC800VMCE1030
Encoder Cable for 1000 Watt and greater, 3 m (9.8 feet)
1
IC800VMTBC005
I/O terminal block and cable (0.5 meter)
1
IC800VMCS030
Communications cable from servo driver to PC, 3 m (9.8 feet)
BC646MBL001
Machine Edition Lite Development Suite with Proficy GlobalCare Complete. Includes VersaMotion configuration tool,
View Development for QuickPanel and LD-PLC Nano/Micro. Proficy GlobalCare with 15 months of free upgrades which is
renewable on an annual basis.
Programming Software for Control, Display and Motion
1
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.173
Durus
Programmable Controllers
Durus Controllers
The Durus PLUS Controllers are loaded
with features such as easy to use
built-in display/keypad, high current
outputs, and multiple communication
options and very affordable. They can
be programmed using both the built-in
display and keypad or with the Durus
Controllers programming software. The
Durus PLUS Controllers are ideal for
applications that require some logic, a
few timers/counters and real-time clock
control. They provide added features
such as math, PID and data move
functionality. The Durus Plus Controllers
are designed for simple control applications such as light control, gate control,
HVAC, pump control and much more.
Key Features:
• Isolated 8 Amp Relay Outputs,
analog in and out and temperature
monitoring
• Support for Ethernet, Modbus Slave,
Profibus Slave and DeviceNet Slave
• Durus Controllers Software enables
the user to fully simulate applications
without the hardware
• Memory Module enables easy
program downloads without a PC
• Software is free for downloading
from the Web
• LCD Backlit display for easy viewing
in all environments
AC Models
pages 1.175-1.176
Backlit LCD Display
DC Models
pages 1.177-1.180
Keypad
Discrete Expansion Units
page 1.181
Analog Expansion Unit
page 1.182
Communications Options
page 1.183
Software
page 1.184
Accessories
page 1.185
Configuration Guidelines
page 1.186
Socket for memory module or
communications interface cable
Optional Expansion (Up to 3 discrete
and 1 analog expansion units)
Durus Controllers Selection Guide
Features
Built-in Discrete I/O
Maximum Discrete I/O
Built-in Analog I/O
I/O Expansion Units
Logic Memory
Programming Language
Execution Speed
LCD Display
Maximum Text Displays
Display Languages
Address Assignments
Coils
Real Time Clock
Number of Timers
Number of Counters
Math Functions
PID
Data Multiplexer
Analog Ramp Control
Comparator Instruction
High Speed Input Frequency
PWM Output Frequency
Modbus Master Built-in
Modbus Slave Support Built-in
Modbus Slave Support
Profibus Slave Support
DeviceNet Slave Support
Agency Approvals
Temperature Range
1.174
Durus PLUS –10 and -12
Durus PLUS –20
6 in/4 out
12 in/8 out (AC powered models) 8 in/8 out (DC powered models)
18 in/16 out
24 in/20 out
2 on DC powered models
4 on DC powered models
Maximum of eight expansion bases are supported.
• Up to 3 Discrete I/O modules
• 1 Analog input module
• 1 Temperature input module (RTD)
• Up to 2 Analog output modules
• 1 Communications module
300 Lines (4 cells wide per rung) or 260 Function Blocks
Ladder or Function Block Diagram (FBD)
10ms/cycle
4 line x16 character LCD backlit display
31
English, French, German, Spanish, Portuguese, Chinese, Italian
Up to 32 discrete inputs and 146 outputs; 8 analog inputs, 4 RTD inputs and 4 analog outputs; 240 registers (16 bit signed or unsigned)
63 Auxiliary M, 63 Auxiliary N Coils and 31 HMI Coils
Up to 15 uses (250 FBD)
Up to 31; 0.01seconds to 9999 minutes (250 FBD)
Up to 31; 0 to 999999 counts (250 FBD)
Up to 31: Add, Subtract (250 FBD); Up to 31 Multiply, Divide (250 FBD)
Up to 15: PI and PID (30 FBD)
Up to 15: Four registers deep (250 FBD)
Up to 15: Multiple steps supported (30 FBD)
Up to 31; Supports <= or >= for Timers, Counters or Analog (250 FBD)
1kHz
0.5kHz (1msec On, 1msec Off)
No
Yes on selective models
No
Yes (built-in on certain models and available for all controllers that support expansion (Modbus Slave expansion module)
Yes
Yes
CE, C-UL, UL
0°C to 55°C
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Durus
AC Models
Durus Controllers
The AC versions of the Durus Controllers come with 10 points (6 discrete inputs and 4
­discrete outputs) or 20 points (12 discrete inputs and 8 discrete outputs). The units are
­available with or without display and keypad and with or without expansion. Up to 3
­discrete and 1 analog expansion units can be added for either additional I/O. One
­communication module can be added.
IC210DAR012
IC210DAR010
Product Name
10 point (8) 24 VAC Inputs,
(4) Isolated Relay Out
(8 Amps), 24 VAC input power,
supports expansion and
display/keypad
10 point (6) AC Inputs,
(4) Isolated Relay Out
(8 Amps), AC input power,
supports expansion and
display/keypad
Lifecycle Status
Active
Active
Active
Active
Number of Discrete Inputs/Outputs
8 In/ 4 Out
6 In/ 4 Out
6 In/ 4 Out
6 In/ 4 Out
Number of Analog Inputs/Outputs
None built in,
4 with Analog Expansion
None built in,
4 with Analog Expansion
None built in,
4 with Analog Expansion
None
34 I/O
34 I/O
34 I/O
34 I/O
Yes
Yes
Yes
No
Yes (4 lines x 12 characters)
Yes (4 lines x 12 characters)
No
No
User Program Logic Memory
200 Rungs and 99 Blocks
200 Rungs and 99 Blocks
200 Rungs and 99 Blocks
200 Rungs and 99 Blocks
Modbus Slave, DeviceNet
Slave, Profibus Slave
expansion modules
Modbus Slave, DeviceNet
Slave, Profibus Slave
expansion modules
Modbus Slave, DeviceNet
Slave, Profibus Slave
expansion modules
None
Protocols Supported
Input Power Voltage
24 VAC
85 to 240 VAC; 85 to 240 VDC
85 to 240 VAC; 85 to 240 VDC
85 to 240 VAC; 85 to 240 VDC
90 mAmps
90 mAmps
90 mAmps
90 mAmps
Physical I/O Maximum
Support Expansion
LCD Display and Keypad
Power Supply Power Consumption
Input Device Voltage
Output Control Voltage
Dimensions (W x H x D) mm
www.ge-ip.com
IC210BAR010
IC210NAR010
10 point (6) AC Inputs,
10 point (6) AC Inputs,
(4) Isolated Relay Out
(4) Isolated Relay Out
(8 Amps), AC input power, sup(8 Amps), AC input power,
ports expansion and
no expansion, no plastic case
no display/keypad
and no display/keypad
24 VAC
85 to 240 VAC; 85 to 240 VDC
85 to 240 VAC; 85 to 240 VDC
85 to 240 VAC
250 VAC / 30 VDC Relay
Outputs, 8A Resistive Load
(Isolated)
250 VAC / 30 VDC Relay
Outputs, 8A Resistive Load
(Isolated)
250 VAC / 30 VDC Relay
Outputs, 8A Resistive Load
(Isolated)
250 VAC / 30 VDC Relay
Outputs, 8A Resistive Load
(Isolated)
72mm x 90mm x 58mm
72 mm x 90 mm x 58 mm
72 mm x 90 mm x 58 mm
72 mm x 90 mm x 58 mm
GE Intelligent Platforms Control Systems Solutions 1.175
Durus
Programmable Controllers
AC Models
1.176
The AC versions of the Durus Controllers come with 10 points (6 discrete inputs and 4
­discrete outputs) or 20 points (12 discrete inputs and 8 discrete outputs). The units are
­available with or without display and keypad and with or without expansion. Up to 3
­discrete and 1 analog expansion units can be added for either additional I/O. One
­communication module can be added.
IC210DAR020
IC210BAR020
IC210NAR020
Product Name
20 point (12) AC Inputs,
(8) Isolated Relay Out
(8 Amps), AC input power,
supports expansion and
display/keypad
20 point (12) AC Inputs,
(8) Isolated Relay Out
(8 Amps), AC input power,
supports expansion and
no display/keypad
20 point (12) AC Inputs,
(8) Isolated Relay Out
(8 Amps), AC input power,
no expansion and
no display/keypad
Lifecycle Status
Active
Active
Active
Number of Discrete Inputs/Outputs
12 In/ 8 Out
12 In/ 8 Out
12 In/ 8 Out
Number of Analog Inputs/Outputs
None built in,
4 with Analog Expansion
None built in,
4 with Analog Expansion
None
44 I/O
44 I/O
44 I/O
Yes
Yes
No
Yes (4 lines x 12 characters)
No
No
User Program Logic Memory
200 Rungs and 99 Blocks
200 Rungs and 99 Blocks
200 Rungs and 99 Blocks
Modbus Slave, DeviceNet
Slave, Profibus Slave
expansion modules
Modbus Slave, DeviceNet
Slave, Profibus Slave
expansion modules
None
Protocols Supported
Input Power Voltage
85 to 240 VAC; 85 to 240 VDC
85 to 240 VAC; 85 to 240 VDC
85 to 240 VAC; 85 to 240 VDC
150 mAmps
150 mAmps
150 mAmps
85 to 240 VAC; 85 to 240 VDC
85 to 240 VAC; 85 to 240 VDC
85 to 240 VAC; 85 to 240 VDC
Output Control Voltage
250 VAC / 30 VDC Relay
Outputs, 8A Resistive Load
(Isolated)
250 VAC / 30 VDC Relay
Outputs, 8A Resistive Load
(Isolated)
250 VAC / 30 VDC Relay
Outputs, 8A Resistive Load
(Isolated)
Dimensions (W x H x D) mm
126 mm x 90 mm x 58 mm
126 mm x 90 mm x 58 mm
126 mm x 90 mm x 58 mm
Physical I/O Maximum
Support Expansion
LCD Display and Keypad
Power Supply Power Consumption
Input Device Voltage
1.176
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Durus
DC Models
The DC versions of the Durus Controllers come in either 12 point (6 discrete inputs, 2 analog
and 4 discrete outputs) or 20 point (12 discrete inputs [analog inputs can be configured as
either discrete inputs or analog inputs], 4 analog inputs and 8 discrete outputs). The units
also support high speed inputs and PWM outputs. The units are available with or without
display and keypad and with or without expansion. Up to 3 discrete and 1 analog expansion
units can be added for either additional I/O. One communication module can be added.
IC210DDR112
Product Name
Lifecycle Status
IC210DDR012
IC210BDR012
IC210NDR012
10 point (6) 12 VDC Inputs,
10 point (6) 24 VDC Inputs,
10 point (6) 24 VDC Inputs,
10 point (6) 24 VDC Inputs,
(2) analog inputs*, (4) Isolated (2) analog inputs*, (4) Isolated, (2) analog inputs*, (4) Isolated, (2) analog inputs*, (4) Isolated,
Relay Out (8 Amps),
Relay Out (8 Amps),
Relay Out (8 Amps),
Relay Out (8 Amps),
12 VDC input power,
24 VDC input power,
24 VDC input power,
24 VDC input power,
supports expansion and
supports expansion and
supports expansion and
no expansion, no plastic case
display/keypad
display/keypad
display/keypad
and no display/keypad
Active
Active
Active
Active
Number of Discrete Inputs/Outputs
6* In/ 4 Out
6* In/ 4 Out
6* In/ 4 Out
6* In/ 4 Out
Number of Analog Inputs/Outputs
2 built in, 4 additional with
Analog Expansion
2 built in, 4 additional with
Analog Expansion
2 built in, 4 additional with
Analog Expansion
2 built in
36 I/O
36 I/O
36 I/O
36 I/O
Yes
Yes
Yes
No
Yes (4 lines x 12 characters)
Yes (4 lines x 12 characters)
No
No
Physical I/O Maximum
Support Expansion
LCD Display and Keypad
User Program Logic Memory
Protocols Supported
Input Power Voltage
Power Supply Power Consumption
Input Device Voltage
200 Rungs and 99 Blocks
200 Rungs and 99 Blocks
200 Rungs and 99 Blocks
200 Rungs and 99 Blocks
Modbus Slave, DeviceNet
Slave, Profibus Slave
expansion modules
Modbus Slave, DeviceNet
Slave, Profibus Slave
expansion modules
Modbus Slave, DeviceNet
Slave, Profibus Slave
expansion modules
None
12 VDC
24 VDC
24 VDC
24 VDC
90 mAmps
90 mAmps
90 mAmps
90 mAmps
12 VDC
24 VDC
24 VDC
24 VDC
High Speed Frequency
1KHz
1KHz
1KHz
1KHz
Output Control Voltage
250 VAC / 30 VDC Relay
Outputs, 8A Resistive Load
(Isolated)
250 VAC / 30 VDC Relay
Outputs, 8A Resistive Load
(Isolated)
250 VAC / 30 VDC Relay
Outputs, 8A Resistive Load
(Isolated)
250 VAC / 30 VDC Relay
Outputs, 8A Resistive Load
(Isolated)
N/A
N/A
N/A
N/A
10 bits
10 bits
10 bits
10 bits
0 to 10 VDC
0 to 10 VDC
0 to 10 VDC
0 to 10 VDC
Input Current:
0.63 mA @ 24 VDC
Input ON Current:
0.161 mA @ 9.8 VDC
Input OFF Current:
0.085 mA @ 5 VDC
Input Current:
0.63 mA @ 24 VDC
Input ON Current:
0.161 mA @ 9.8 VDC
Input OFF Current:
0.085 mA @ 5 VDC
Input Current:
0.63 mA @ 24 VDC
Input ON Current:
0.161 mA @ 9.8 VDC
Input OFF Current:
0.085 mA @ 5 VDC
Input Current:
0.63 mA @ 24 VDC
Input ON Current:
0.161 mA @ 9.8 VDC
Input OFF Current:
0.085 mA @ 5 VDC
72 mm x 90 mm x 58 mm
72 mm x 90 mm x 58 mm
72 mm x 90 mm x 58 mm
72mm x 90mm x 58mm
PWM Maximum Output Frequency
Analog Resolution
Analog Input Range
Analog Input Used as Digital Input
Dimensions (W x H x D) mm
* Analog inputs can be configured as DC input points.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.177
Durus
Programmable Controllers
DC Models
The DC versions of the Durus Controllers come in either 12 point (6 discrete inputs, 2 analog
and 4 discrete outputs) or 20 point (12 discrete inputs [analog inputs can be configured as
either discrete inputs or analog inputs], 4 analog inputs and 8 discrete outputs). The units
also support high speed inputs and PWM outputs. The units are available with or without
display and keypad and with or without expansion. Up to 3 discrete and 1 analog expansion
units can be added for either additional I/O. One communication module can be added.
Product Name
Lifecycle Status
IC210DDD012
IC210BDD012
IC210NDD012
IC210MDR124
10 point (6) 24 VDC Inputs,
(4) 24 VDC Out (Transistor
0.5 Amp), (2) analog inputs*,
24 VDC input power,
supports expansion and
display/keypad
10 point (6) 24 VDC Inputs,
(4) 24 VDC Out (Transistor
0.5 Amp), (2) analog inputs*,
24 VDC input power,
supports expansion,
no display/keypad
10 point (6) 24 VDC Inputs,
(4) 24 VDC Out (Transistor
0.5 Amp), (2) analog inputs*,
24 VDC input power,
no expansion, no plastic
case and no display/keypad
20 point with Modbus Slave
communications built-in
(8) 12 VDC Inputs, (4) analog
inputs*, (8) Isolated Relay Out
(8 Amps), 12 VDC input power,
supports expansion and
display/keypad
Active
Active
Active
Active
Number of Discrete Inputs/Outputs
6* In/ 4 Out
6* In/ 4 Out
6* In/ 4 Out
8* In/ 8 Out
Number of Analog Inputs/Outputs
2 built in, 4 additional with
Analog Expansion
2 built in, 4 additional with
Analog Expansion
2 built in
4 built in, 4 with
Analog Expansion
36 I/O
36 I/O
36 I/O
44 I/O
Yes
Yes
No
Yes
Yes (4 lines x 12 characters)
No
No
Yes (4 lines x 12 characters)
Physical I/O Maximum
Support Expansion
LCD Display and Keypad
User Program Logic Memory
Protocols Supported
Input Power Voltage
Power Supply Power Consumption
Input Device Voltage
High Speed Frequency
200 Rungs and 99 Blocks
200 Rungs and 99 Blocks
200 Rungs and 99 Blocks
200 Rungs and 99 Blocks
Modbus Slave, DeviceNet
Slave, Profibus Slave
expansion modules
Modbus Slave, DeviceNet
Slave, Profibus Slave
expansion modules
None
Modbus Slave built in, and
Modbus Slave, DeviceNet
Slave, Profibus Slave
expansion modules
24 VDC
24 VDC
24 VDC
12 VDC
90 mAmps
90 mAmps
90 mAmps
90 mAmps
24 VDC
24 VDC
24 VDC
12 VDC
1KHz
1KHz
1KHz
1KHz
24 VDC Transistors
24 VDC Transistors
24 VDC Transistors
250 VAC / 30 VDC Relay
Outputs, 8A Resistive Load
(Isolated)
0.5K (1ms ON/ 1ms OFF)
100Hz
100Hz
N/A
10 bits
10 bits
10 bits
10 bits
0 to 10 VDC
0 to 10 VDC
0 to 10 VDC
0 to 10 VDC
Input Current:
0.63 mA @ 24 VDC
Input ON Current:
0.161 mA @ 9.8 VDC
Input OFF Current:
0.085 mA @ 5 VDC
Input Current:
0.63 mA @ 24 VDC
Input ON Current:
0.161 mA @ 9.8 VDC
Input OFF Current:
0.085 mA @ 5 VDC
Input Current:
0.63 mA @ 24 VDC
Input ON Current:
0.161 mA @ 9.8 VDC
Input OFF Current:
0.085 mA @ 5 VDC
Input Current:
0.63 mA @ 24 VDC
Input ON Current:
0.161 mA @ 9.8 VDC
Input OFF Current:
0.085 mA @ 5 VDC
72 mm x 90 mm x 58 mm
72 mm x 90 mm x 58 mm
“72 mm x 90 mm x 58 mm
126 mm x 90 mm x 58 mm
Output Control Voltage
PWM Maximum Output Frequency
Analog Resolution
Analog Input Range
Analog Input Used as Digital Input
Dimensions (W x H x D) mm
* Analog inputs can be configured as DC input points.
1.178
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Durus
DC Models
The DC versions of the Durus Controllers come in either 12 point (6 discrete inputs, 2 analog
and 4 discrete outputs) or 20 point (12 discrete inputs [analog inputs can be configured as
either discrete inputs or analog inputs], 4 analog inputs and 8 discrete outputs). The units
also support high speed inputs and PWM outputs. The units are available with or without
display and keypad and with or without expansion. Up to 3 discrete and 1 analog expansion
units can be added for either additional I/O. One communication module can be added.
Product Name
Lifecycle Status
IC210DDR024
IC210BDR024
IC210NDR024
IC210DDD024
20 point (8) 24 VDC Inputs,
(4) analog inputs*,
(8) Isolated Relay Out
(8 Amps), 24 VDC input power,
supports expansion and
display/keypad
20 point (8) 24 VDC Inputs,
(4) analog inputs*,
(8) Isolated Relay Out
(8 Amps), 24 VDC input
power, supports expansion,
no display/keypad
20 point (8) 24 VDC Inputs,
(4) analog inputs*,
(8) Isolated Relay Out
(8 Amps), 24 VDC input
power, no expansion,
no plastic case and
no display/keypad
20 point (4) 24 VDC Inputs,
(8) 24 VDC Out (Transistor
0.5 Amp), (4) analog inputs*,
24 VDC input power,
supports expansion and
display/keypad
Active
Active
Active
Active
Number of Discrete Inputs/Outputs
8* In/ 8 Out
8* In/ 8 Out
8* In/ 8 Out
8* In/ 8 Out
Number of Analog Inputs/Outputs
4 built in, 4 with
Analog Expansion
4 built in, 4 with
Analog Expansion
4 built in
4 built in, 4 with
Analog Expansion
44 I/O
44 I/O
44 I/O
44 I/O
Yes
Yes
No
Yes
Yes (4 lines x 12 characters)
No
No
Yes (4 lines x 12 characters)
Physical I/O Maximum
Support Expansion
LCD Display and Keypad
User Program Logic Memory
Protocols Supported
Input Power Voltage
Power Supply Power Consumption
Input Device Voltage
200 Rungs and 99 Blocks
200 Rungs and 99 Blocks
200 Rungs and 99 Blocks
200 Rungs and 99 Blocks
Modbus Slave, DeviceNet
Slave, Profibus Slave
expansion modules
Modbus Slave, DeviceNet
Slave, Profibus Slave
expansion modules
None
Modbus Slave, DeviceNet
Slave, Profibus Slave
expansion modules
24 VDC
24 VDC
24 VDC
24 VDC
90 mAmps
90 mAmps
90 mAmps
90 mAmps
24 VDC
24 VDC
24 VDC
24 VDC
High Speed Frequency
1KHz
1KHz
1KHz
1KHz
250 VAC / 30 VDC Relay
Outputs, 8A Resistive Load
(Isolated)
250 VAC / 30 VDC Relay
Outputs, 8A Resistive Load
(Isolated)
24 VDC Transistors
Output Control Voltage
250 VAC / 30 VDC Relay
Outputs, 8A Resistive Load
(Isolated)
N/A
N/A
N/A
100Hz
10 bits
10 bits
10 bits
10 bits
0 to 10 VDC
0 to 10 VDC
0 to 10 VDC
0 to 10 VDC
Input Current:
0.63 mA @ 24 VDC
Input ON Current:
0.161 mA @ 9.8 VDC
Input OFF Current:
0.085 mA @ 5 VDC
Input Current:
0.63 mA @ 24 VDC
Input ON Current:
0.161 mA @ 9.8 VDC
Input OFF Current:
0.085 mA @ 5 VDC
Input Current:
0.63 mA @ 24 VDC
Input ON Current:
0.161 mA @ 9.8 VDC
Input OFF Current:
0.085 mA @ 5 VDC
Input Current:
0.63 mA @ 24 VDC
Input ON Current:
0.161 mA @ 9.8 VDC
Input OFF Current:
0.085 mA @ 5 VDC
126 mm x 90 mm x 58 mm
126 mm x 90 mm x 58 mm
126 mm x 90 mm x 58 mm
126 mm x 90 mm x 58 mm
PWM Maximum Output Frequency
Analog Resolution
Analog Input Range
Analog Input Used as Digital Input
Dimensions (W x H x D) mm
* Analog inputs can be configured as DC input points.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.179
Durus
Programmable Controllers
DC Models
The DC versions of the Durus Controllers come in either 12 point (6 discrete inputs, 2 analog
and 4 discrete outputs) or 20 point (12 discrete inputs [analog inputs can be configured as
either discrete inputs or analog inputs], 4 analog inputs and 8 discrete outputs). The units
also support high speed inputs and PWM outputs. The units are available with or without
display and keypad and with or without expansion. Up to 3 discrete and 1 analog expansion
units can be added for either additional I/O. One communication module can be added.
IC210BDD024
Product Name
Lifecycle Status
20 point (8) 24 VDC Inputs,
(8) 24 VDC Out (Transistor
0.5 Amp), (4) analog inputs*,
24 VDC input power,
supports expansion,
no display/keypad
IC210NDD024
IC210MDR024
20 point (8) 24 VDC Inputs,
20 point with Modbus Slave
(8) 24 VDC Out (Transistor
communications built-in
0.5 Amp), (4) analog inputs*,
(8) 24 VDC Inputs, (4) analog
24 VDC input power,
inputs*, (8) Isolated Relay Out
no expansion, no plastic case (8 Amps), 24 VDC input power,
and no display/keypad
supports expansion and
display/keypad
20 point Modbus Slave
communications built-in
(8) 24 VDC Inputs, (8) 24 VDC
Out (Transistor 0.5 Amp),
(4) analog inputs*,
24 VDC input power,
supports expansion and
display/keypad
Active
Active
Number of Discrete Inputs/Outputs
8* In/ 8 Out
8* In/ 8 Out
8* In/ 8 Out
8* In/ 8 Out
Number of Analog Inputs/Outputs
4 built in, 4 with
Analog Expansion
4 built in
4 built in, 4 with
Analog Expansion
4 built in, 4 with
Analog Expansion
44 I/O
44 I/O
44 I/O
44 I/O
Support Expansion
Yes
No
Yes
Yes
LCD Display and Keypad
No
No
Yes (4 lines x 12 characters)
Yes (4 lines x 12 characters)
Physical I/O Maximum
User Program Logic Memory
Protocols Supported
Input Power Voltage
Power Supply Power Consumption
Input Device Voltage
High Speed Frequency
Active
IC210MDD024
Active
200 Rungs and 99 Blocks
200 Rungs and 99 Blocks
200 Rungs and 99 Blocks
200 Rungs and 99 Blocks
Modbus Slave, DeviceNet
Slave, Profibus Slave
expansion modules
None
Modbus Slave built in, and
Modbus Slave, DeviceNet
Slave, Profibus Slave
expansion modules
Modbus Slave built in, and
Modbus Slave, DeviceNet
Slave, Profibus Slave
expansion modules
24 VDC
24 VDC
24 VDC
24 VDC
90 mAmps
90 mAmps
90 mAmps
90 mAmps
24 VDC
24 VDC
24 VDC
24 VDC
1KHz
1KHz
1KHz
1KHz
24 VDC Transistors
24 VDC Transistors
250 VAC / 30 VDC Relay
Outputs, 8A Resistive Load
(Isolated)
24 VDC Transistors
PWM Maximum Output Frequency
100Hz
100Hz
N/A
100Hz
Analog Resolution
10 bits
10 bits
10 bits
10 bits
0 to 10 VDC
0 to 10 VDC
0 to 10 VDC
0 to 10 VDC
Input Current:
0.63 mA @ 24 VDC
Input ON Current:
0.161 mA @ 9.8 VDC
Input OFF Current:
0.085 mA @ 5 VDC
Input Current:
0.63 mA @ 24 VDC
Input ON Current:
0.161 mA @ 9.8 VDC
Input OFF Current:
0.085 mA @ 5 VDC
Input Current:
0.63 mA @ 24 VDC
Input ON Current:
0.161 mA @ 9.8 VDC
Input OFF Current:
0.085 mA @ 5 VDC
Input Current:
0.63 mA @ 24 VDC
Input ON Current:
0.161 mA @ 9.8 VDC
Input OFF Current:
0.085 mA @ 5 VDC
126 mm x 90 mm x 58 mm
126 mm x 90 mm x 58 mm
126 mm x 90 mm x 58 mm
126 mm x 90 mm x 58 mm
Output Control Voltage
Analog Input Range
Analog Input Used as Digital Input
Dimensions (W x H x D) mm
* Analog inputs can be configured as DC input points.
1.180
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Durus
Discrete Expansion Units
The Durus Controllers support a maximum of 7 I/O expansion modules and 1 communications
module. The expansion supports a maximum of 3 discrete modules, 1 analog input module,
1 temperature input module (RTD), and 2 analog output expansion units.
IC210EAR008
IC210EAR208
IC210EDR008
IC210EDD008
Product Name
8 point discrete expansion
(4) AC Inputs, (4) Isolated
Relay Out (8 Amps), AC input
power
Lifecycle Status
Active
Active
Active
Active
4 In/ 4 Out
4 In/ 4 Out
4 In/ 4 Out
4 In/ 4 Out
85 to 240 VAC; 85 to 240 VDC
24 VAC
24 VDC
24 VDC
90 mAmps
90 mAmps
90 mAmps
90 mAmps
85 to 240 VAC; 85 to 240 VDC
24 VAC
24 VDC
24 VDC
38 mm x 90 mm x 58 mm
38 mm x 90 mm x 58 mm
38 mm x 90 mm x 58 mm
38 mm x 90 mm x 58 mm
Number of Discrete Inputs/Outputs
Input Power Voltage
Power Supply Power Consumption
Input Device Voltage
Dimensions (W x H x D) mm
www.ge-ip.com
8 point discrete expansion
8 point discrete expansion
(4) 24 VAC Inputs, (4) Isolated (4) 24 VDC Inputs, (4) Isolated
Relay Out (8 Amps), AC input Relay Output (8 Amps), 24 VDC
power
input power
8 point discrete expansion
(4) 24 VDC Inputs, (4) 24 VDC
Out (Transistor 0.5 Amp), 24
VDC input power
GE Intelligent Platforms Control Systems Solutions 1.181
Durus
Programmable Controllers
Analog Expansion Unit
The Durus Controllers support a maximum of 7 I/O expansion modules and 1 communications module. The total expansion supports 3 discrete modules, 1 analog input module, 1
temperature input module (RTD), and 2 analog output expansion units.
IC210EAI004
IC210EPT004
IC210EAO002
Product Name
4 point analog expansion
(4) analog inputs
(voltage and current, 12 bit),
12/24 VDC input power
Only one analog expansion
supported on the Durus Controller
4 channel PT 100, 12bit,
PT100 (-100°~600°).
Maximum of temperature
modules supported on
the Durus Controller.
2 channel analog out expansion
(0 – 10VDC or 0 – 20mA).
Maximum of 2 analog
output modules supported on
the Durus Controller.
Lifecycle Status
Active
Active
Active
4
4
Number of Channels
Input Type
Output Type
Analog Input Range
0 to 10 VDC; 0 to 20 mA
0 to 10VDC
0 to 20mA
Analog Output Range
Resolution
12 bits
0.1C
10mV for Voltage
40 micro Amps for Current
Analog Output Register Range
Temperature Range
Dimensions (W x H x D) mm
1.182
10mV for Voltage
40 micro Amps for Current
-100 to 600C
38 mm x 90 mm x 58 mm
GE Intelligent Platforms Control Systems Solutions
38mm x 90mm x 58mm
38mm x 90mm x 58mm
www.ge-ip.com
Programmable Controllers
Durus
Communications Options
The Durus Controllers support one communication expansion unit. There are three
communication options available—Modbus Slave, Profibus Slave and DeviceNet Slave.
IC210EMS001
IC210EPS001
IC210EDS001
Product Name
Modbus RTU slave communications
expansion module,
24 VDC power source
Profibus-DP slave communications
expansion module,
24 VDC power source
DeviceNet slave communications
expansion module,
24 VDC power source
Lifecycle Status
Active
Active
Active
Protocol Supported
Modbus Slave
Profibus-DP Slave V0
DeviceNet Group 2 Only Slave Device
Network Data Rate
4800, 9600, 19200, 38400, 57600
9.6K to 12 Meg
125K, 250K, 500 K
38 mm x 90 mm x 58 mm
38 mm x 90 mm x 58 mm
38 mm x 90 mm x 58 mm
Connector Type
Dimensions (W x H x D) mm
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 1.183
Durus
Programmable Controllers
Software
Full featured Durus Software (IC646DUR001) enables you to develop your application in ladder logic or Function Block
Diagram programming. The Durus Software also comes with a powerful simulation tool that enables you to easily simulate
your application and mimic the keystrokes on the built-in operator keypad.
Pump Starter
B01
AND
I01
I
Test Pressure
B03
Tank Fill
N01
OR
N
Level Sensors
B02
AND
Function Block Diagram
Ladder Logic
fpo
I/O Addressing
Easy-to-Use Application Development Simulation on the PC.
User can simulate your entire application without powering up a Durus Controller.
1.184
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Programmable Controllers
Durus
Accessories and Cables
IC210TMP001
Durus Controllers FLASH Memory Pack that enables user to download application and upload application
to Durus Controller
Active
IC210CBL001
Durus Controller to PC RS-232 Serial Cable
Active
IC210CBL002
Durus Controller to PDA Transfer Cable
Active
Programming and Trouble Shooting Tools
IC646DUR101
Durus Controllers Program and Simulation Software and PC to Controller RS-232 Cable (IC646DUR001
and IC210CBL001)
Active
IC210TBX010
IC210DAR010 10 point Durus controller. AC Power Source, 6 AC in/4out (Relay 8 Amp), Expandable,
with LCD/Keypad. Kit includes programming software and cable. (IC646DUR101)
Active
IC210TBX012
IC210DDR012 12 point Durus controller. 24 VDC Power Source, (6) 24 VDC in /(4) out (Relay 8 Amp),
(2) analog inputs, Expandable, with LCD/Keypad. Kit includes programming software and cable. (IC646DUR101)
Active
IC210TBX020
IC210DAR020 20 point Durus controller. AC Power Source, (12) AC in/8 out (Relay, 8 Amp), Expandable,
with LCD/Keypad. Kit includes programming software and cable. (IC646DUR101)
Active
IC210TBX024
IC210DDR024 20 point Durus-20 controller. 24 point 24 VDC Power Source, (8) 24 VDC in/8 out (Relay, 8 Amp),
(4) analog inputs, Expandable, with LCD/Keypad. Kit includes programming software and cable. (IC646DUR101)
IC210MDR024 20 point Durus-20 controller. 24 VDC Power Source, (8) 24 VDC in/8 out (Relay, 8 Amp),
(4) analog inputs, Expandable, with LCD/Keypad. Support Modbus Slave on port. Kit includes programming
software and cable. (IC646DUR101)
Active
Starter Kits
IC210TBX124
www.ge-ip.com
Active
GE Intelligent Platforms Control Systems Solutions 1.185
Durus
Programmable Controllers
Examples of Typical Application using a Series 90-30
Configuration for Durus Controller 10 (Applications needing less than 6 (120/240 VAC) inputs and 4 relay outputs)
Qty
Part Number
Description
1
IC210DAR010
AC Power Source, 6 AC in/4 out (Relay 8 Amp), Expandable, with LCD/Keypad
Options to consider
1
IC646DUR101
Durus Controllers Program and Simulation Software and PC to Controller RS-232 Cable (IC646DUR001 and IC210CBL001)
1
IC210TMP001
Durus Controllers FLASH Memory Pack that enables user to download application and upload application to Durus Controllers
1
IC210EMS001
Modbus RTU slave communications expansion module, 24 VDC power source
1
IC200DTX450
Operator Interface with up to 200 stored messages. 2 x 16 character LCD backlight display and 6 function keys.
(Requires 24 VDC power supply)
Configuration for Durus Controller 10 (Example Application needing 16 (24 VDC) discrete inputs, 12 relay outputs and 8
Analog inputs with 24 VDC power and Modbus communications. Modbus communications will connect to Operator Interface
that requires 4 x 20 line display and numeric keypad)
Qty
Part Number
Description
1
IC210MDR024
24 VDC Power Source, (12) 24 VDC in/8 out (Relay, 8 Amp), (4) analog inputs, Expandable, with LCD/Keypad. Support Modbus Slave on port.
2
IC210EDR008
24 VDC Power Source, (4) 24 VDC in/(4) out (Relay, 8 Amp)
1
IC210EAI004
24 VDC power source, 10 bit, 4 Analog input
1
IC200DTX850
Operator Interface with up to 200 stored messages. 4 x 20 character LCD backlight display, 8 function keys and numeric keypad.
Options to consider
1
IC646DUR101
Durus Controllers Program and Simulation Software and PC to Controller RS-232 Cable (IC646DUR001 and IC210CBL001)
1
IC210TMP001
Durus Controllers FLASH Memory Pack that enables user to download application and upload application to Durus Controllers
Application requiring six 24 VDC inputs, eight AC inputs, thirteen relay outputs, no display required
and Profibus networking.
Qty
Part Number
Description
1
IC210BAR020
AC Power Source, (12) AC in/8 out (Relay, 8 Amp), Expandable, with without LCD/Keypad
2
IC210EDR008
24 VDC Power Source, (4) 24 VDC in/(4) out (Relay, 8 Amp)
1
IC210EPS001
Profibus-DP slave communications expansion module, 24 VDC power source
Options to consider
1
IC646DUR101
Durus Controllers Program and Simulation Software and PC to Controller RS-232 Cable (IC646DUR001 and IC210CBL001)
1
IC210TMP001
Durus Controllers FLASH Memory Pack that enables user to download application and upload application to Durus Controllers
1.186
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Process Control Systems
Table of Contents
Proficy Process Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.3
Proficy Process Systems Overview. . . . . . . . . . . . . . . . . . . 2.3
Product Selection Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.6
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
2.1
Table Of Contents
2.2
GE Intelligent Platforms Control Systems Solutions
Process Control Systems
www.ge-ip.com
Process Control Systems
Proficy Process Systems
Proficy Process Systems Overview
Proficy Process Systems is a state-of-the-art, scalable, fully-integrated
system for process automation and control. It provides the hardware
and software needed for a complete process control system. Whether
your business has continuous or batch oriented process control
needs, Proficy Process Systems will deliver results. Based on contemporary, yet well proven technologies, Proficy Process Systems
combines the power of traditional DCS systems with the flexibility,
freedom and affordability of a PLC-based approach.
Operator
Consoles
Engineering
Workstations
ERP
Batch
Server
Historian and
Change
Management
et
Ethern
Applications
PACSystems
ASI
DeviceNet
Ethernet
Foundation
Fieldbus
Genius
Hart
PACSystems I/O
Profibus DP/PA
VersaMax
3rd Party
Controllers
Control
I/O
us
Fieldb
Fieldbus and I/O
Architecture Overview
The Proficy Process Systems architecture is designed to provide a modular and
expandable system to meet your most demanding process control needs. Proficy
Process Systems can uniquely range from a small, one-machine architecture to a
large, multi-machine architecture. This approach means you can start small and
expand your system over time, at your pace. The system consists of several layers.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
2.3
Process Control Systems
Proficy Process Systems
Applications Layer
The Applications Layer contains the software that powers the
information capabilities of Proficy Process Systems, featuring:
Engineering Workstation
This is where you design, create, and maintain your system’s
configuration. With an advanced Logic Developer, you can
create your control strategies in Function Blocks, Ladder
Logic, or Structured Text for the PACSystems controllers.
Operator Console
This is where your operators monitor and control the
process. Choose between our two industry leading
HMI/SCADA visualization technologies for your system –
CIMPLICITY* or iFIX*. The consoles communicate with the
PACSystems controllers through our Global Namespace.
Engineering Workstation
Historian
The Historian is designed specifically for handling process
data. It provides high performance storage and retrieval
with sub-second collection and millisecond time-stamping.
Change Management
Change Management provides version control for your
process control strategies, including audit trail capabilities.
Batch Execution
Batch Execution is the perfect option for batch-oriented
processes. With advanced batch management, formulation
management, batch direct, and tight linkage with our Batch
Analysis option, you can optimize campaigns and batch runs.
Operator Console
ERP Connectivity
GE Intelligent Platforms have closed the gap between
automation and information with our Proficy Production
Management software products and ERP connector. Now
you can link your control system to your business systems
to truly drive operational excellence in your business.
2.4
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Process Control Systems
Proficy Process Systems
Controllers
The PACSystems RX7i and RX3i give Proficy Process Systems
its flexibility, featuring a common engine which allows you
to take programs that are created in one controller and
easily move them to another.
Proficy Process Systems also features Control Memory
Exchange, a breakthrough technology incorporated from
GE’s Embedded Systems Business. Through high-speed fiber
optics, Control Memory Exchange allows data in one controller
to be exchanged and shared with another controller at over a
2 giga baud rate. This allows you to synchronize controllers
for distributed control, or reflect the memory state of one
controller to another for redundant operations.
PACSystems RX7i
PACSystems RX3i
Fieldbus and I/O
GE has always taken an open approach with our products
and technologies. We provide our customers with the best
possible technology and give them the freedom to work
with the devices and instruments of their choice.
Proficy Process Systems continues with that tradition. We
understand that when it comes to process control, there
are several choices for Fieldbuses. That’s why we chose an
Open Fieldbus approach to our system which supports the
major Fieldbuses including:
• Foundation Fieldbus
• Profibus™
• Hart
• AS-I Interface
• Ethernet
We also provide you with a comprehensive portfolio of I/O,
allowing you to choose the right strategy to meet your
needs. Through OPC, native drivers, and by teaming with
companies that specialize in Fieldbus and I/O connectivity,
we can satisfy your connectivity needs – putting you in
control of your Fieldbus strategy.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
2.5
Process Control Systems
Proficy Process Systems
Product Selection Guide
Notes on Part Numbers and GlobalCare
• Support must be quoted on all new Proficy Process Systems
• Change IC prefix to GC for 15 months of GlobalCare Support
Notes on Licensing
• All Process Systems Licenses are based on Hardware Keys
• System architecture (number of nodes and types) is required at time of
order to ensure correct license key manufacture
Proficy Process Systems Products
Proficy Process Systems
Part Number
Lifecycle Status
Engineering Workstation
Operator Console
Historian
Change Management
Includes
IC647PSF050
IC647PSF100
IC647PSF200
IC647PSF300
IC647PSF500
IC647PSF000
Active
Active
Active
Active
Active
Active
1
1
1
1
1
1
1
1
1
1
1
1
500 Tag
1000 Tag
2000 Tag
3000 Tag
5000 Tag
5000+ Tag
1
1
1
1
1
1
Proficy Process Systems with CIMPLICITY and Global Care
Proficy Process Systems - CIMPLICITY - 500 I/O
IC647PSC050
Proficy Process Systems - CIMPLICITY - 1000 I/O
IC647PSC100
Proficy Process Systems - CIMPLICITY - 2000 I/O
IC647PSC200
Proficy Process Systems - CIMPLICITY - 3000 I/O
IC647PSC300
Proficy Process Systems - CIMPLICITY - 5000 I/O
IC647PSC500
Proficy Process Systems - CIMPLICITY - 5000+ I/O IC647PSC000
Active
Active
Active
Active
Active
Active
1
1
1
1
1
1
1
1
1
1
1
1
500 Tag
1000 Tag
2000 Tag
3000 Tag
5000 Tag
5000+ Tag
1
1
1
1
1
1
Proficy Process Systems with iFIX and GlobalCare
Proficy Process Systems - iFIX - 500 I/O
Proficy Process Systems - iFIX - 1000 I/O
Proficy Process Systems - iFIX - 2000 I/O
Proficy Process Systems - iFIX - 3000 I/O
Proficy Process Systems - iFIX - 5000 I/O
Proficy Process Systems - iFIX - 5000+ I/O
Product Options
Used to add additional users to your system beyond
those included with the base packages above
Additional Engineering Workstation - iFIX
Additional Engineering Workstation - CIMPLICITY
Additional Operator Console - iFIX
Additional Operator Console - CIMPLICITY
Proficy Process Systems EGD OPC Server
Part Number
IC647PPSEWF
IC647PPSEWC
IC647PPSOCF
IC647PPSOCC
IC647PPSOPC
Lifecycle Status
Active
Active
Active
Active
Active
Complementary Products
These products can be used to expand the capabilities of
your Process Systems
Change Management
Change Management 1 user
Change Management 5 users
Change Management 10 users
Change Management 25 users
Change Management Scheduler
Part Number
IC646PCM001
IC646PCM005
IC646PCM010
IC646PCM025
IC646PCMSCH
Lifecycle Status
Mature
Mature
Mature
Mature
Mature
Batch
Batch Server Small
Batch Server Medium
Batch Server Large
Batch Developer
Batch Client
2.6
Part Number
IC647BSS000
IC647BSM000
IC647BSL000
IC647BSD000
IC647BSC999
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
Table of Contents
VersaMax I/O. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3
VersaPoint and VersaSafe I/O . . . . . . . . . . . . . . . . . . . . . . . 3.53
CPUs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4
Network Interface Modules. . . . . . . . . . . . . . . . . . . . . . . . . 3.54
Carriers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5
Power Terminals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.55
I/O Interposing Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.8
Segment Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.56
Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.10
Discrete Input Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.57
Discrete Mixed I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . 3.12
Discrete Output Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . 3.58
Discrete Input Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.16
Analog Input Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.60
Discrete Output Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . 3.22
Analog Output Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.61
Analog Input Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.25
Functional Safety Modules . . . . . . . . . . . . . . . . . . . . . . . . . 3.62
Analog Output Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.27
Motion Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.63
Analog Mixed Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.29
Motor Starter Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.64
RTD and Thermocouple Modules. . . . . . . . . . . . . . . . . . . . 3.30
Serial Communications Modules. . . . . . . . . . . . . . . . . . . . 3.65
Speciality Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.31
Accessories and Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.66
Expansion Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.32
Configuration Guidelines; Typical Applications. . . . . . . 3.67
Remote I/O Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.33
Network Interface Modules. . . . . . . . . . . . . . . . . . . . . . . . . 3.35
VersaMax IP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.68
Serial Communications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.36
Stand Alone Input and Output Modules. . . . . . . . . . . . . 3.69
Accessories, Cables, Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.37
VersaMax IP Modular. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.70
Configuration Guidelines; Typical Applications. . . . . . . 3.38
Accessories and Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.72
Configuration Guidelines; Typical Applications. . . . . . . 3.73
Genius I/O. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.40
AC Discrete I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.41
RSTi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.74
DC Discrete I/O Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.42
Network Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.75
Analog Input Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.44
Network Interfaces with Built-in I/O. . . . . . . . . . . . . . . . . 3.77
Analog Output Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.45
Discrete I/O Modules (Input) . . . . . . . . . . . . . . . . . . . . . . . . 3.88
Analog Mixed Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.46
Analog I/O Modules (Input) . . . . . . . . . . . . . . . . . . . . . . . . . 3.91
RTD and Thermocouple Modules. . . . . . . . . . . . . . . . . . . . 3.47
Discrete I/O Modules (Output). . . . . . . . . . . . . . . . . . . . . . . 3.94
High Speed Counter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.48
Analog I/O Modules (Output). . . . . . . . . . . . . . . . . . . . . . . . 3.99
PowerTRAC Monitoring Module. . . . . . . . . . . . . . . . . . . . . 3.49
RTD Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.102
Accessories, Cables, Hand Held Monitor. . . . . . . . . . . . . 3.50
Thermocouple Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.103
Configuration Guidelines; Typical Applications. . . . . . . 3.51
Serial Communications Modules. . . . . . . . . . . . . . . . . . . 3.104
Continued next page
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.1
Table Of Contents
Industrial I/O
RSTi Continued
High Speed Counting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.106
Motion Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.108
Power Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.110
Expansion Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.113
Configuration Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.114
Accessories and Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . 3.116
Typical Application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.117
3.2
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax I/O
VersaMax I/O and Control
By choosing GE, customers gain access
to a complete line of highly versatile
and robust I/O modules that offer
seamless integration with the
PACSystems control family, for reliable,
high performance solutions.
The modular design of VersaMax I/O
addresses a wide range of discrete and
process applications. Its innovative
modular architecture combines power
and versatility to help provide performance in a compact control solution.
Power Supplies
pages 3.10-3.11
Analog I/O Modules
pages 3.25-3.29
Discrete I/O Modules
pages 3.12-3.24
Network Interface Modules
CPUs
Carriers
I/O Interposing Bases
The VersaMax PROFINET network
interface provides integrated I/O to
PACSystems controllers in both copper
and fiber interface. Ideal for any
remote I/O application, the PROFINET
interface supports ring topology, which
permits a node to go down or break
without transmission interruption.
and complexity. These requirements
extend to the I/O that they use.
GE’s I/O solutions provide the high
performance control solutions with
best-in-class integration of distributed
(networked) I/O to meet these demanding applications.
Equipment builders are continuously
looking for ways to improve the
performance of their equipment while
augmenting usability and reducing size
page 3.35
page 3.4
pages 3.5-3.7
pages 3.8-3.9
Expansion Modules
RTD and Thermocouple Modules
Specialty Modules
Remote I/O Units
Serial Communications
page 3.32
page 3.30
Accessories
Configuration Guidelines
page 3.37
pages 3.38-3.39
page 3.31
pages 3.33-3.34
page 3.36
Publication Reference Chart
GFK-1179
Installation Requirements for Conformance to Standards
GFK-1697
VersaMax System AS-i Network Master Module User’s Manual
GFK-1503
VersaMax PLC User’s Manual
GFK-1847
Remote I/O Manager User’s Manual
GFK-1504
VersaMax Modules, Power Supplies, and Carriers User’s Manual
GFK-1852
VersaMax Serial to Ethernet Adapter User’s Manual
GFK-1533
VersaMax System DeviceNet Communications Modules User’s Manual
GFK-1860
VersaMax System Ethernet Network Interface Unit User’s Manual
GFK-1534
VersaMax System Profibus Network Modules User’s Manual
GFK-1868
Proficy Machine Edition Getting Started Guide
GFK-1535
VersaMax System Genius Network Interface Unit User’s Manual
GFK-1876
VersaMax Ethernet Station Manager Manual
VersaMax I/O and Industrial Networking Application Guide
IC690CDU002 InfoLink for PLC CD-ROM
GFK-1563
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.3
VersaMax I/O
Industrial I/O
CPUs
VersaMax CPUs supply a number of features usually found only in PLCs with larger footprints, including up to 128K of memory for application programs, floating point math, and
real-time clock. With a modular and scalable architecture, the VersaMax CPU is ideal for
standalone control applications with up to 256 local I/O or expanded systems of up to
4,096 I/O points.
IC200CPU001
IC200CPU002
IC200CPU005
IC200CPUE05
Product Name
VersaMax PLC CPU 32K
Configurable Memory, 2 Ports
RS-232 and RS-485
VersaMax PLC CPU 42K
Configurable Memory, 2 Ports
RS-232 and RS-485
VersaMax PLC CPU 128K Configurable User Memory, 2 Ports
RS-232 and RS-485
VersaMax PLC CPU 128K Configurable User Memory, 2 Ports
RS-232 and RS-485, 10 MBIT
Ethernet Port. Supports EGD
and SRTP.
Lifecycle Status
Active
Active
Active
Active
I/O Discrete Points
2048 in, 2048 out
2048 in, 2048 out
2048 in, 2048 out
2048 in, 2048 out
I/O Analog Words
Configurable
Configurable
Configurable
Configurable
Registers
Configurable
Configurable
Configurable
Configurable
Discrete Internal Bits
1024 points
1024 points
1024 points
1024 points
Discrete Temporary Bits
256 points
256 points
256 points
256 points
Global Discrete Bits
1280 points
1280 points
1280 points
1280 points
Program Memory
Configurable
Configurable
Configurable
Configurable
1.8 ms/K (typical)
1.8 ms/K (typical)
0.8 ms/K (typical)
0.8 ms/K (typical)
Floating Points
Yes
Yes
Yes
Yes
Override
Yes
Yes
Yes
Yes
SNP Slave, RTU Master
and Slave, Serial I/O
SNP Slave, RTU Master
and Slave, Serial I/O
SNP Slave, RTU Master and
Slave, Serial I/O
10 MBIT Ethernet Port,
Slave, RTU Master and Slave,
Serial I/O
System flash,
battery-backed RAM
System flash,
battery-backed RAM
System flash,
battery-backed RAM
System flash,
battery-backed RAM
Yes
Yes
Yes
Yes
40 with no EZ Store attached;
140 when EZ Store attached
40 with no EZ Store attached;
140 when EZ Store attached
80 with no EZ Store attached;
180 when EZ Store attached
160 with no EZ Store attached;
260 when EZ Store attached
100
100
290 (Requires a power supply
with 3.3 VDC expanded)
650 (Requires a power supply
with 3.3 VDC expanded)
2.63” (66.8 mm) x
5.04” (128 mm)
2.63” (66.8 mm) x
5.04” (128 mm)
4.20” (106.7 mm) x
5.04” (128 mm)
4.95” (126 mm) x
5.04” (128 mm)
Boolean Execution Speed
Built-in Communications
Type of Memory Storage
Battery-Backed Real-time Clock
5V Backplane Current
Consumption (mA)
3.3V Backplane Current
Consumption (mA)
Dimensions (W x H)
3.4
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax I/O
Carriers
VersaMax provides several types of snap-together I/O carriers and interposing terminals
to provide maximum wiring flexibility, as well as module hot insertion and removal.
VersaMax carriers support IEC box-style, spring-style, and barrier-style terminals and are
also available as snap-on auxiliary terminal strips and interposing terminals that can be
mounted separately and connected to a connector-style carrier by an I/O cable.
IC200CHS022
IC200CHS025
Product Name
VersaMax Compact I/O Carrier,
Local Box Clamp Connection Style
VersaMax Compact I/O Carrier,
Local Spring Clamp Connection Style
Lifecycle Status
Active
Active
Field Termination Type
Integrated
Integrated
Wiring Termination Style
Local Box
Local Spring
Orientation on Module on Base
Dimensions (W x H x D)
Cables
www.ge-ip.com
Vertical
Vertical
66.8 mm (2.63 in) x 163.5 mm (6.45 in) x 70 mm (2.75 in),
not including the height of DIN Rail
66.8 mm (2.63 in) x 163.5 mm (6.45 in) x 70 mm (2.75 in),
not including the height of DIN Rail
N/A
N/A
GE Intelligent Platforms Control Systems Solutions
3.5
VersaMax I/O
Industrial I/O
Carriers
VersaMax provides several types of snap-together I/O carriers and interposing terminals to
provide maximum wiring flexibility, as well as module hot insertion and removal. VersaMax
carriers support IEC box-style, spring-style, and barrier-style terminals and are also available as snap-on auxiliary terminal strips and interposing terminals that can be mounted
separately and connected to a connector-style carrier by an I/O cable.
IC200CHS001
IC200CHS002
IC200CHS005
VersaMax I/O Carrier,
Local Barrier Style
VersaMax I/O Carrier,
Local Box Style
VersaMax I/O Carrier,
Local Spring Clamp
Connection Style
Active
Active
Active
Integrated
Integrated
Integrated
Barrier
Box
Spring
Horizontal
Horizontal
Horizontal
110.5 mm (4.35 in) x
139.7 mm (5.5 in) x
70 mm (2.75 in),
not including the
height of DIN Rail
110.5 mm (4.35 in) x
139.7 mm (5.5 in) x
70 mm (2.75 in),
not including the
height of DIN Rail
110.5 mm (4.35 in) x
139.7 mm (5.5 in) x
70 mm (2.75 in),
not including the
height of DIN Rail
N/A
N/A
N/A
Product Name
Lifecycle Status
Field Termination Type
Wiring Termination Style
Orientation on
Module on Base
Dimensions (W x H x D)
Cables
3.6
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax I/O
Carriers
VersaMax provides several types of snap-together I/O carriers and interposing
terminals to provide maximum wiring flexibility, as well as module hot insertion
and removal. VersaMax carriers support IEC box-style, spring-style, and barrierstyle terminals and are also available as snap-on auxiliary terminal strips and
interposing terminals that can be mounted separately and connected to a
­connector-style carrier by an I/O cable.
IC200CHS003
IC200CHS011
IC200CHS012
IC200CHS014
IC200CHS015
VersaMax I/O Carrier,
Interposing Box Style
(Requires IC200CHS003
base and connecting
cable IC200CBL1xxx)
VersaMax I/O Carrier,
Interposing Box
Thermocouple
Compensation
(Requires IC200CHS003
base and connecting
cable IC200CBL1xxx)
VersaMax I/O Carrier,
Interposing Spring Clamp
(Requires IC200CHS003
base and connecting
cable IC200CBL1xxx)
VersaMax I/O Carrier,
Interposing Spring Clamp
(Requires IC200CHS003
base and connecting
cable IC200CBL1xxx)
Product Name
VersaMax I/O Carrier,
VersaMax I/O Carrier,
Connector Style. Interposing
Barrier A connecting cable Style
(Requires (IC200CBL1xxx) and
IC200CHS003 base interposing
base (IC200CHS011, and
connecting CHS012, CHS014,
CHS015, cable IC200CBL1xxx)
IC200CHS1xx or IC200CHS2xx)
are required. This carrier can be
used with all VersaMax I/O
modules EXCEPT the following,
due to their high isolation
requirements: IC200MDL144
Input 240 VAC 4 Point Isolated
Module; IC200MDL244 Input 240
VAC 8 Point Isolated Module;
IC200MDD850 Mixed 240 VAC
Isolated 4 Point / Output Relay
2.0A Isolated 8 Point Module
Lifecycle Status
Active
Active
Active
Active
Active
Integrated
Non-Integrated
Non-Integrated
Integrated
Non-Integrated
Connector
Barrier
Box
Box-Thermocouple
Compensation
Spring
Vertical
N/A
N/A
N/A
N/A
Dimensions (W x H x D)
66.8 mm (2.63 in) x
133.4 mm (5.25 in) x
70 mm (2.75 in),
not including the
height of DIN Rail
110.5 mm (4.35 in) x
105.4 mm (2.63 in) x
70 mm (2.75 in),
not including the
height of DIN Rail
110.5 mm (4.35 in) x
105.4 mm (2.63 in) x
70 mm (2.75 in),
not including the
height of DIN Rail
110.5 mm (4.35 in) x
105.4 mm (2.63 in) x
70 mm (2.75 in),
not including the
height of DIN Rail
110.5 mm (4.35 in) x
105.4 mm (2.63in) x
70 mm (2.75 in),
not including the
height of DIN Rail
Cables
Requires a
IC200CBL1xxx cable
Requires a
IC200CBL1xxx cable
Requires a
IC200CBL1xxx cable
Requires a
IC200CBL1xxx cable
Requires a
IC200CBL1xxx cable
Field Termination Type
Wiring Termination Style
Orientation on
Module on Base
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.7
VersaMax I/O
Industrial I/O
I/O Interposing Bases
VersaMax I/O interposing disconnect bases enable the IC200CHS003 to connect to a
wide range of termination bases. The Relay bases provide additional protection and
higher amperage outputs. The Disconnect bases enables the user to easily disconnect
signals, on a per point bases, from the I/O module.
IC200CHS003
IC200CHS101
IC200CHS102
IC200CHS111
Product Name
VersaMax I/O Carrier,
Connector Style.
A connecting cable
(IC200CBL1xxx) and
interposing base
(IC200CHS011, CHS012,
CHS014, CHS015, IC200CHS1xx
or IC200CHS2xx) are required.
This carrier can be used with
all VersaMax I/O modules
EXCEPT the following, due
to their high isolation
requirements: IC200MDL144
Input 240 VAC 4 Point Isolated
Module; IC200MDL244 Input
240 VAC 8 Point Isolated
Module; IC200MDD850
Mixed 240 VAC Isolated
4 Point / Output Relay 2.0A
Isolated 8 Point Module
Input or Output Interposing
Disconnect Style 16 Points.
The base has an individual
knife-switch disconnect
for each signal and common
terminal and its corresponding
pin on the VersaMax cable
connector. Requires
IC200CHS003 and a connecting
cable IC200CBL1xxx.
Expansion Input or Output
Interposing Disconnect Style
16 Points. The base has an
individual knife-switch
disconnect for each signal
and common terminal and
its corresponding pin on the
VersaMax cable connector.
Requires a IC200CHS101 main
base, can not be directly
connected to IC200CHS003.
I/O Interposing Relay Base
(replaceable relays), fused
(8 amps, replaceable), 16 points.
The relays on these interposing
terminals are intended to
be controlled with standard
24 VDC 0.5A VersaMax output
modules (IC200MDL740 and
IC200MDL750 using
IC200CHS003 base and
connected by IC200CBL1xxx).
Lifecycle Status
Active
Active
Active
Active
Field Termination Type
Integrated
Non-Integrated
Non-Integrated
Non-Integrated
Wiring Termination Style
Connector
Box
Box
Box
Removable Terminals Connectors
N/A
No
No
No
N/A
All discrete modules supported
except MDL144, 244, 331, 730
and MDD840, 843, 850.
All discrete modules supported
except MDL144, 244, 331, 730
and MDD840, 843, 850.
24 VDC from MDL740
and MDL750
N/A
All discrete modules supported
except MDL144, 244, 331, 730
and MDD840, 843, 850.
All discrete modules supported
except MDL144, 244, 331, 730
and MDD840, 843, 850.
0-125 VDC, 5/24/125 VDC
nominal; 0-265 VAC (47-63 Hz),
120/240 VAC nominal
N/A
N/A
N/A
8.0 A for 5-265 VAC,
2.0 A for 5-30 VDC,
0.2 A for 31-125 VDC
(Replaceable Fuse)
N/A
N/A
N/A
Replaceable Fuse
Input Voltage
Output Voltage
Load Current per Point
Protection
Points per Common
Dimensions (W x H x D)
Cables
3.8
N/A
N/A
N/A
Isolated Per Point
66.8 mm (2.63 in) x 133.4 mm
(5.25 in) x 70 mm (2.75 in),
not including the
height of the DIN Rail
115 mm (4.5 in) x 126 mm
(4.95 in) x 65 mm (2.6 in),
not including the
height of the DIN Rail
115 mm (4.5 in) x 126 mm
(4.95 in) x 65 mm (2.6 in),
not including the
height of the DIN Rail
253.7 mm (9.9 in) x 126 mm
(4.95 in) x 73 mm (2.8 in),
not including the
height of the DIN Rail
Requires a
IC200CBL1xxx cable
Requires a
IC200CBL1xxx cable
N/A
Requires a
IC200CBL1xxx cable
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax I/O
I/O Interposing Bases
VersaMax I/O interposing disconnect bases enable the IC200CHS003 to connect to a
wide range of termination bases. The Relay bases provide additional protection and
higher amperage outputs. The Disconnect bases enables the user to easily disconnect
signals, on a per point bases, from the I/O module.
IC200CHS112
IC200CHS211
IC200CHS212
I/O Interposing Relay Base
(replaceable relays), fused
(8 amps, replaceable), 16 points.
The relays on these interposing
terminals are intended to be
controlled with standard 24 VDC
0.5A VersaMax output modules
(IC200MDL740 and IC200MDL750
using IC200CHS003 base and
connected by IC200CBL1xxx).
Expansion base.
I/O Interposing Relay Base
(replaceable relays), fused
(8 amps, replaceable), 16 points.
Field terminals are removable.
The relays on these interposing
terminals are intended to be
controlled with standard 24 VDC
0.5A VersaMax output modules
(IC200MDL740 and IC200MDL750
using IC200CHS003 base and
connected by IC200CBL1xxx).
I/O Interposing Relay Base
(replaceable relays), fused
(8 amps, replaceable), 16 points.
Field terminals are removable.
The relays on these interposing
terminals are intended to be
controlled with standard 24 VDC
0.5A VersaMax output modules
(IC200MDL740 and IC200MDL750
using IC200CHS003 base and
connected by IC200CBL1xxx).
Expansion base.
Active
Active
Active
Non-Integrated
Non-Integrated
Non-Integrated
Connection Style
Box
Box
Box
Removable Terminals Connectors
No
Yes
Yes
24 VDC from MDL740
and MDL750
24 VDC from MDL740
and MDL750
24 VDC from MDL740
and MDL750
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz),
120/240 VAC nominal
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz),
120/240 VAC nominal
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz),
120/240 VAC nominal
8.0 A for 5-265 VAC, 2.0 A for 5-30 VDC, 0.2
A for 31-125 VDC (Replaceable Fuse)
8.0 A for 5-265 VAC, 2.0 A for 5-30 VDC, 0.2
A for 31-125 VDC (Replaceable Fuse)
8.0 A for 5-265 VAC, 2.0 A for 5-30 VDC, 0.2
A for 31-125 VDC (Replaceable Fuse)
Protection
Replaceable Fuse
Replaceable Fuse
Replaceable Fuse
Points per Common
Isolated Per Point
Isolated Per Point
Isolated Per Point
253.7 mm (9.9 in) x 126 mm (4.95 in) x 73
mm (2.8 in), not including the height of the
DIN Rail
253.7 mm (9.9 in) x 126 mm (4.95 in) x 73
mm (2.8 in), not including the height of the
DIN Rail
253.7 mm (9.9 in) x 126 mm (4.95 in) x 73
mm (2.8 in), not including the height of the
DIN Rail
N/A
Requires a
IC200CBL1xxx cable
N/A
Product Name
Lifecycle Status
Field Termination Type
Input Voltage
Output Voltage
Load Current per Point
Dimensions (W x H x D)
Cables
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.9
VersaMax I/O
Industrial I/O
Power Supplies
VersaMax Power Supply modules snap onto any VersaMax CPU or Network Interface Unit or
onto a power supply booster carrier. Each power supply can be used as the main power
source for modules in the I/O station, or as a source of supplemental power for larger I/O
applications.
IC200PWR001
IC200PWR002
IC200PWR011
IC200PWR012
IC200PWR101
24 VDC Power Supply
24 VDC Power Supply
with Expanded 3.3 V
24VDC Isolated
Power Supply
24VDC Isolated
Power Supply with
Expanded 3.3 V
120/240 VAC
Power Supply
Lifecycle Status
Active
Active
Active
Active
Active
Input Voltage
24 VDC
24 VDC
24 VDC
24 VDC
120/240 VAC
Output Voltage
5 VDC, 3.3 VDC
5 VDC, 3.3 VDC
5 VDC, 3.3 VDC
5 VDC, 3.3 VDC
5 VDC, 3.3 VDC
Extended Power
No
Yes
No
Yes
No
11 W
11 W
11 W
11 W
27 VA
No
No
Yes
Yes
N/A
Product Name
Input Power
Isolated Power
Holdup Time
Inrush Current
Protection
Total Output Current
3.3V Output Current
5V Output Current
Dimensions (W x H x D)
3.10
10 ms
10 ms
10 ms
10 ms
20 ms
20 A @ 24 VDC;
25 A @ 30 VDC
20 A @ 24 VDC;
25 A @ 30 VDC
20 A @ 24 VDC;
25 A @ 30 VDC
20 A @ 24 VDC;
25 A @ 30 VDC
N/A
Short circuit, overload,
reverse polarity
Short circuit, overload,
reverse polarity
Short circuit, overload,
reverse polarity
Short circuit, overload,
reverse polarity
Short circuit, overload
1.5 A maximum
1.5 A maximum
1.5 A maximum
1.5 A maximum
1.5 A maximum
0.25 A maximum
1.0 A maximum
0.25 A maximum
1.0 A maximum
0.25 A maximum
1.5 A minus the 3.3V
current used, maximum
1.5 A minus the 3.3V
current used, maximum
1.5 A minus the 3.3V
current used, maximum
1.5 A minus the 3.3V
current used, maximum
1.5 A minus the 3.3V
current used, maximum
49 mm (1.93 in) x
133.4 mm (5.25 in) x
39 mm (1.54 in),
not including the
height of the carrier
or the DIN Rail
49 mm (1.93 in) x
133.4 mm (5.25 in) x
39 mm (1.54 in),
not including the
height of the carrier
or the DIN Rail
49 mm (1.93 in) x
133.4 mm (5.25 in) x
39 mm (1.54 in),
not including the
height of the carrier
or the DIN Rail
49 mm (1.93 in) x
133.4 mm (5.25 in) x
39 mm (1.54 in),
not including the
height of the carrier
or the DIN Rail
49 mm (1.93 in) x
133.4 mm (5.25 in) x
39 mm (1.54 in),
not including the
height of the carrier
or the DIN Rail
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax I/O
Power Supplies
VersaMax Power Supply modules snap onto any VersaMax CPU or Network Interface Unit or
onto a power supply booster carrier. Each power supply can be used as the main power
source for modules in the I/O station, or as a source of supplemental power for larger I/O
applications.
IC200PWR102
IC200PWR201
IC200PWR202
IC200PWB001
120/240 VAC Power Supply
with Expanded 3.3 VDC
12 VDC Power Supply
12 VDC Power Supply
with Expanded 3.3 VDC
VersaMax Power Supply
Booster Carrier.
Supplies power to all
modules to the right
of booster. Requires
power supply.
Active
Active
Active
Active
120/240 VAC
9.6-15 VDC, 12 VDC nominal
9.6-15 VDC, 12 VDC nominal
N/A
Output Voltage
5 VDC, 3.3 VDC
5 VDC, 3.3 VDC
5 VDC, 3.3 VDC
N/A
Extended Power
Yes
No
Yes
N/A
27 VA
11 W
11 W
N/A
N/A
No
No
N/A
Product Name
Lifecycle Status
Input Voltage
Input Power
Isolated Power
Holdup Time
Inrush Current
Protection
Total Output Current
3.3V Output Current
5V Output Current
Dimensions (W x H x D)
www.ge-ip.com
20 ms
10 ms
10 ms
N/A
N/A
25 A at 12 VDC; 30 A at 15 VDC
25 A at 12 VDC; 30 A at 15 VDC
N/A
Short circuit, overload
Short circuit, overload,
reverse polarity
Short circuit, overload,
reverse polarity
N/A
1.5 A maximum
1.5 A maximum
1.5 A maximum
N/A
1.0 A maximum
0.25 A maximum
1.0 A maximum
N/A
1.5 A minus the 3.3V
current used, maximum
1.5 A minus the 3.3 V
current used, maximum
1.5 A minus the 3.3 V
current used, maximum
N/A
49 mm (1.93 in) x
133.4 mm (5.25 in) x
39 mm (1.54 in),
not including the
height of the carrier
or the DIN Rail
49 mm (1.93 in) x
133.4 mm (5.25 in) x
39 mm (1.54 in),
not including the
height of the carrier
or the DIN Rail
49 mm (1.93 in) x
133.4 mm (5.25 in) x
39 mm (1.54 in),
not including the
height of the carrier
or the DIN Rail
66.8 mm (2.63 in) x
133.4 mm (5.25 in) x
70 mm (2.75 in),
not including the
height of DIN Rail
GE Intelligent Platforms Control Systems Solutions
3.11
VersaMax I/O
Industrial I/O
Discrete Mixed I/O Modules
Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single,
compact module. Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches that can have two states: on or off, open or closed. Discrete output modules
send control signals to devices such as contactors, indicator lamps, and interposing relays that can
also have two states. Discrete mixed modules provide maximum flexibility by combining inputs and
outputs in a single, compact module. Modules require a carrier base (IC200CHSxxx).
IC200MDD840
IC200MDD842
IC200MDD843
Product Name
VersaMax Discrete Mixed Modules,
24 VDC Pos Logic Input 20 points/Output
Relay 2.0 A, 12 points
VersaMax Discrete Mixed Modules
24 VDC Pos Logic Input 16/Output
24 VDC 0.5 A with ESCP
VersaMax Discrete Mixed Modules
24 VDC Positive Logic Input
10/Output Relay 6
Lifecycle Status
Active
Active
Active
Input Voltage
24 VDC
24 VDC
24 VDC
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz),
120/240 VAC nominal
24 VDC
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz),
120/240 VAC nominal
20 in/12 out
16 in/16 out
10 in/6 out
No
No
No
2.0 A for 5-265 VAC, 2.0 A for 5-30 VDC
0.5 A for 30 VDC
2.0 A for 5-265 VAC, 2.0 A for 5-30 VDC, 0.2
A for 31-125 VDC
0.5 and 10
0.5 and 0.5
0.5 and 10
No internal fuses or snubbers
Short circuit protection, overcurrent
protection, free-wheeling diodes
No internal fuses or snubbers
On State Current
2.0-5.5 mA
2.0-5.5 mA
2.0-5.5 mA
Off State Current
0-0.5 mA
0-0.5 mA
0-0.5 mA
0-125 VDC, 5/24/125 VDC nominal; 0-265
VAC (47-63 Hz), 120/240 VAC nominal
18-30 VDC, 24 VDC nominal
0-125 VDC, 5/24/125 VDC nominal, 0-265
VAC (47-63 Hz), 120/240 VAC nominal
10 kOhms maximum
10 kOhms maximum
10 kOhms maximum
2.0 A for 5-265 VAC or
5-30 VDC, 0.2 A for 31-125 VDC
0.5 Amp at 30 VDC
maximum (resistive);
2.0 Amps maximum for
100ms inrush
10mA per point minimum,
8.0A maximum per module;
2.0 Amps for 5 to 265 VAC
maximum (resistive);
2.0 Amps for 5 to 30 VDC
maximum (resistive);
0.2 Amp for 31 to 125 VDC
maximum (resistive)
375 maximum
100 maximum
190 maximum
LED Indicators
One LED per point shows individual
point on/off state (logic side); OK LED
indicates backplane power is present
One LED per point shows individual
point on/off state (logic side); OK LED
indicates backplane power is present
One LED per point shows individual
point on/off state (logic side); OK LED
indicates backplane power is present
Dimensions (W x H x D)
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
Output Voltage
Number of Points
Channel to Channel Isolation
Load Current per Point
Input and Output Response
Time- On/Off(ms)
Protection
External Power Supply
Input Impedance
Load Current
5V Backplane Current
Consumption (mA)
3.12
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax I/O
Discrete Mixed I/O Modules
Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single,
compact module. Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches that can have two states: on or off, open or closed. Discrete output modules
send control signals to devices such as contactors, indicator lamps, and interposing relays that can
also have two states. Discrete mixed modules provide maximum flexibility by combining inputs and
outputs in a single, compact module. Modules require a carrier base (IC200CHSxxx).
IC200MDD844
IC200MDD845
IC200MDD846
Product Name
VersaMax Discrete Mixed
Modules 24 VDC Positive Logic
Input 16/Output 24 VDC 0.5 A 16 points
VersaMax Discrete Mixed
Modules 24 VDC Positive Logic Input
16/Output Relay 2.0A Isolated 8 points
VersaMax Discrete Mixed Modules
120 VAC Input 8 points/Outpoints
Relay 2.0A Isolated 8 points
Lifecycle Status
Active
Active
Active
Input Voltage
24 VDC
24 VDC
120 VAC
24 VDC
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz),
120/240 VAC nominal
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz),
120/240 VAC nominal
16 in/16 out
16 in/8 out
8 in/8 out
No
Yes, outputs
Yes, outputs
0.5 A for 30 VDC
2.0 A for 5-265 VAC, 2.0 A for 5-30 VDC,
0.2 A for 31-125 VDC
2.0 A for 5-265 VAC, 2.0 A for 5-30 VDC,
0.2 A for 31-125 VDC
0.5 and 0.2 ON / 1.0 OFF
0.5 and 10
1 AC cycle minimum and 2 AC cycle
(Hz dependent) maximum and 10.0 OFF
No internal fuses
No internal fuses or snubbers
No internal fuses or snubbers
On State Current
2.0-5.5 mA
2.0-5.5 mA
5 mA minimum
Off State Current
0-0.5 mA
0-0.5 mA
2.5 mA maximum
Output Voltage
Number of Points
Channel to Channel Isolation
Load Current per Point
Input and Output Response
Time- On/Off(ms)
Protection
External Power Supply
Input Impedance
18-30 VDC, 24 VDC nominal
10 kOhms maximum
0.5 Amp at 30 VDC maximum (resistive) 2.0
Amps maximum for 100ms inrush
Load Current
5V Backplane Current
Consumption (mA)
0-125 VDC, 5/24/125 VDC nominal;
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz), 120/240 VAC nominal 0-265 VAC (47-63 Hz), 120/240 VAC nominal
10 kOhms maximum
8.6 kOhms (reactive) at 60 Hz, typical;
10.32 kOhms (reactive) at 50 Hz, typical
10mA per point minimum
10mA per point minimum
2.0A for 5 to 265 VAC maximum (resistive)
2.0A for 5 to 265 VAC maximum (resistive)
2.0A for 5 to 30 VDC maximum (resistive)
2.0A for 5 to 30 VDC maximum (resistive)
0.2A for 31 to 125 VDC maximum (resistive) 0.2A for 31 to 125 VDC maximum (resistive)
70 maximum
270 maximum
300 maximum
LED Indicators
One LED per point shows individual
point on/off state (logic side); OK LED
indicates backplane power is present
One LED per point shows individual
point on/off state (logic side); OK LED
indicates backplane power is present
One LED per point shows individual
point on/off state (logic side); OK LED
indicates backplane power is present
Dimensions (W x H x D)
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.13
VersaMax I/O
Industrial I/O
Discrete Mixed I/O Modules
Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single,
compact module. Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches that can have two states: on or off, open or closed. Discrete output modules
send control signals to devices such as contactors, indicator lamps, and interposing relays that can
also have two states. Discrete mixed modules provide maximum flexibility by combining inputs and
outputs in a single, compact module. Modules require a carrier base (IC200CHSxxx).
IC200MDD847
IC200MDD848
IC200MDD849
Product Name
VersaMax Discrete Mixed Modules
240 VAC Input 8 points/Output Relay
2.0A Isolated 8 points
VersaMax Discrete Mixed Modules
120 VAC Input 8 points/Output
120 VAC 0.5A Isolated 8 points
VersaMax Discrete Mixed Modules
120 VAC Input Isolated 8 points/Output
Relay 2.0 A Isolated 8 points
Lifecycle Status
Active
Active
Active
240 VAC
120 VAC
0-132 VAC (47 to 63 Hz), 120 VAC nominal
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz),
120/240 VAC nominal
120 VAC
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz),
120/240 VAC nominal
8 in/8 out
8 in/8 out
8 in/8 out
Yes, outputs
Yes
Yes
Load Current per Point
2.0 A for 5-265 VAC, 2.0 A for 5-30 VDC,
0.2 A for 31-125 VDC
10 mA min, 0.5 A max, 5 A for 1 cycle
(20 ms) max inrush
2.0 A
Input and Output Response
Time- On/Off(ms)
1 AC cycle minimum and 2 AC cycle
(Hz dependent) maximum and 10.0 OFF
1 cycle/2 cycle and
<1/2 cycle/<1/2 cycle
1 cycle/2 cycle and
10/10
No internal fuses or snubbers
Snubber and MOVs (each output)
No internal fuses or snubbers
On State Current
4 mA minimum
5 mA minimum
5 mA minimum
Off State Current
1.5 mA maximum
2.5 mA maximum
2.5 mA maximum
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz), 120/240 VAC nominal
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz), 120/240 VAC nominal
N/A
38.5 kOhms (reactive) at 60 Hz, typical;
46.3 kOhms (reactive) at 50 Hz, typical
8.6 kOhms (reactive) at 60 Hz, typical;
10.32 kOhms (reactive) at 50 Hz, typical
8.6 kOhms (reactive) at 60 Hz, typical;
10.32 kOhms (reactive) at 50 Hz, typical
10mA per point minimum
2.0 Amps for 5 to 265 VAC maximum (resistive)
2.0 Amps for 5 to 30 VDC maximum (resistive)
0.2 Amp for 31 to 125 VDC maximum (resistive)
10 mA minimum per point,
0.5 A maximum per point, 5.0 A for
one cycle (20 ms) maximum inrush
10 mA per point minimum;
2.0 A for 5-265 VAC maximum (resistive);
2.0 A for 5-30 VDC maximum (resistive);
0.2 A for 31-125 VDC maximum (resistive)
300 maximum
125 maximum
300 maximum
One LED per point shows individual point
on/off state (logic side); OK LED indicates
backplane power is present
One LED per point shows individual point
on/off state (logic side); OK LED indicates
backplane power is present
One LED per point shows individual point
on/off state (logic side); OK LED indicates
backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm 1.956 in), not including the
height of (the carrier or the
mating connectors
Input Voltage
Output Voltage
Number of Points
Channel to Channel Isolation
Protection
External Power Supply
Input Impedance
Load Current
5V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
3.14
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax I/O
Discrete Mixed I/O Modules
Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single,
compact module. Discrete input modules receive signals from input devices such as sensors, pushbuttons, and switches that can have two states: on or off, open or closed. Discrete output modules
send control signals to devices such as contactors, indicator lamps, and interposing relays that can
also have two states. Discrete mixed modules provide maximum flexibility by combining inputs and
outputs in a single, compact module. Modules require a carrier base (IC200CHSxxx).
IC200MDD850
IC200MDD851
Product Name
VersaMax Discrete Mixed Modules
240 VAC Input Isolated 4 points/Output
Relay 2.0 A Isolated 8 points
VersaMax Discrete Mixed Modules
5/12 VDC Input 16 points/Output
12/24 VDC 16 points
Lifecycle Status
Active
Active
0-264 VAC (47-63 Hz), 240 VAC nominal
0 to 15 VDC, +5/12 VDC nominal
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz),
120/240 VAC nominal
+10.2 to +30 VDC, +12/24 VDC nominal
8 out/4 in
16 out/16 in
Yes
No
2.0 A
0.5 Amps at 30 VDC maximum (resistive)
2.0 Amps maximum for 100ms inrush
1 cycle/2 cycle
and 10/10
0.25ms maximum/0.2ms ON
and 1.0ms OFF maximum
No internal fuses or snubbers
No internal fuses or snubbers
On State Current
4 mA minimum
1.45mA minimum
Off State Current
1.5 mA maximum
0 to 0.7 mA maximum
N/A
+10.2 to +30 VDC, +12/24 VDC nominal
38.5 kOhms (reactive) at 60 Hz, typical;
46.3 kOhms (reactive) at 50 Hz, typical
2.4kOhms typical @ 12 VDC
10 mA per point minimum;
2.0 A for 5-265 VAC maximum (resistive);
2.0 A for 5-30 VDC maximum (resistive);
0.2 A for 31-125 VDC maximum (resistive)
0.5 Amps at 30 VDC maximum (resistive);
2.0 Amps maximum for 100ms inrush
260 maximum
115 maximum
One LED per point shows individual point
on/off state logic side); OK LED indicates
backplane power is present
One LED per point shows individual point
on/off state (logic side); OK LED indicates
backplane power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
Input Voltage
Output Voltage
Number of Points
Channel to Channel Isolation
Load Current per Point
Input and Output Response
Time- On/Off(ms)
Protection
External Power Supply
Input Impedance
Load Current
5V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.15
VersaMax I/O
Industrial I/O
Discrete Input Modules
Discrete input modules receive signals from input devices such as sensors, pushbuttons, and
switches that can have two states: on or off, open or closed. Modules require a carrier base
(IC200CHSxxx).
IC200MDL140
IC200MDL141
IC200MDL143
Product Name
VersaMax Discrete Input
Module 120 VAC,
8 points
VersaMax Discrete Input
Module 240 VAC,
8 points
VersaMax Discrete Input
Module 120 VAC Isolated,
8 points
Lifecycle Status
Active
Active
Active
0-132 VAC
0-264 VAC
0-132 VAC
8
8
8
No
No
Yes
1 cycle/2 cycles
1 cycle/2 cycles
1 cycle/2 cycles
1 group of 8
1 group of 8
8 groups of 1
On State Current
5 mA minimum
7 mA minimum
5 mA minimum
Off State Current
2.5 mA maximum
1.5 mA maximum
2.5 mA maximum
Input Impedance
8.6 kOhms (reactive) at 60 Hz, typical;
10.32 kOhms (reactive) at 50 Hz, typical
38.5 kOhms (reactive) at 60 Hz, typical;
46.3 kOhms (reactive) at 50 Hz, typical
8.6 kOhms (reactive) at 60 Hz, typical;
10.32 kOhms (reactive) at 50 Hz, typical
55 maximum
55 maximum
50 maximum
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
Input Voltage
Number of Points
Channel to Channel Isolation
Input and Output Response
Time- On/Off (ms)
Points per Common
5V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
3.16
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax I/O
Discrete Input Modules
Discrete input modules receive signals from input devices such as sensors, pushbuttons, and
switches that can have two states: on or off, open or closed. Modules require a carrier base
(IC200CHSxxx).
IC200MDL144
IC200MDL240
IC200MDL241
Product Name
VersaMax Discrete Input
Module 240 VAC Isolated,
4 points
VersaMax Discrete Input
Module, 120 VAC Positive Logic,
16 points
VersaMax Discrete Input
Module, 240 VAC Positive Logic,
16 points
Lifecycle Status
Active
Active
Active
0-264 VAC
0-132 VAC
0-264 VAC
4
16
16
Yes
No
No
1 cycle/2 cycles
1 cycle/2 cycles
1 cycle/2 cycles
4 groups of 1
2 groups of 8
2 groups of 8
On State Current
7 mA minimum
5 mA minimum
4 mA minimum
Off State Current
3 mA maximum
2.5 mA maximum
1.5 mA maximum
Input Impedance
38.5 kOhms (reactive) at 60 Hz, typical;
46.3 kOhms (reactive) at 50 Hz, typical
8.6 kOhms (reactive) at 60 Hz, typical;
10.32 kOhms (reactive) at 50 Hz, typical
38.5 kOhms (reactive) at 60 Hz, typical;
46.3 kOhms (reactive) at 50 Hz, typical
30 maximum
110 maximum
110 maximum
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
Input Voltage
Number of Points
Channel to Channel Isolation
Input and Output Response
Time- On/Off (ms)
Points per Common
5V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.17
VersaMax I/O
Industrial I/O
Discrete Input Modules
Discrete input modules receive signals from input devices such as sensors, pushbuttons, and
switches that can have two states: on or off, open or closed. Modules require a carrier base
(IC200CHSxxx).
IC200MDL243
IC200MDL244
IC200MDL631
Product Name
VersaMax Discrete Input
Module, 120 VAC Isolated,
16 points
VersaMax Discrete Input
Module, 240 VAC Isolated,
8 points
VersaMax Discrete Input
Module 125 VDC, Pos/Neg Logic,
Isolated, 8 points
Lifecycle Status
Active
Active
Active
0-132 VAC
0-264 VAC
0-150 VDC, 125 VDC nominal
Number of Points
16
8
8 isolated inputs
Channel to Channel Isolation
Input Voltage
Yes
Yes
Yes
Input and Output Response
Time- On/Off (ms)
1 cycle/2 cycles
1 cycle/2 cycles
0.5 maximum
Points per Common
16 groups of 1
8 groups of 1
8 groups of 1
On State Current
5 mA minimum
7 mA minimum
1.0 mA minimum
Off State Current
2.5 mA maximum
3 mA maximum
0 to 0.1 mA maximum
Input Impedance
8.6 kOhms (reactive) at 60 Hz, typical;
10.32 kOhms (reactive) at 50 Hz, typical
38.5 kOhms (reactive) at 60 Hz, typical;
46.3 kOhms (reactive) at 50 Hz, typical
74 K Ohm typical at 125 VDC
100 maximum
60 maximum
40 maximum
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
5V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
3.18
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax I/O
Discrete Input Modules
Discrete input modules receive signals from input devices such as sensors, pushbuttons, and
switches that can have two states: on or off, open or closed. Modules require a carrier base
(IC200CHSxxx).
IC200MDL632
IC200MDL635
IC200MDL636
Product Name
VersaMax Discrete Input
Module 125 VDC, Pos/Neg Logic,
Isolated, 16 points
VersaMax Discrete Input Module
48 VDC, Pos/Neg Logic
(2 Groups of 8), 16 points
VersaMax Discrete Input
Module 48 VDC, Pos/Neg Logic
(4 Groups of 8), 32 points
Lifecycle Status
Active
Active
Active
0-150 VDC, 125 VDC nominal
0-60 VDC, 48 VDC nominal
0-60 VDC, 48 VDC nominal
16 isolated inputs
16 inputs (2 groups of 8)
32 (4 groups of 8)
Input Voltage
Number of Points
Channel to Channel Isolation
Yes
No
No
Input and Output Response
Time- On/Off (ms)
0.5 maximum
0.5 maximum
0.5 maximum
Points per Common
16 groups of 1
2 groups of 8
4 groups of 8
On State Current
1.0 mA minimum
1.0 mA minimum
1.0 mA minimum
Off State Current
0 to 0.1 mA maximum
0 to 0.4 mA maximum
0 to 0.4 mA maximum
74 K Ohm typical at 125 VDC
28 K Ohm typical
28 K Ohm typical
80 maximum
70 maximum
140 maximum
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
Input Impedance
5V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.19
VersaMax I/O
Industrial I/O
Discrete Input Modules
Discrete input modules receive signals from input devices such as sensors, pushbuttons, and
switches that can have two states: on or off, open or closed. Modules require a carrier base
(IC200CHSxxx).
IC200MDL640
IC200MDL643
IC200MDL644
IC200MDL650
Product Name
VersaMax Discrete Input
Module, 24 VDC
Pos/Neg Logic, 16 points
VersaMax Discrete Input
Module, 5/12 VDC (TTL)
Pos/Neg Logic, 16 points
VersaMax Discrete Input
Module, 5/12 VDC (TTL)
Pos/Neg Logic, 32 points
VersaMax Discrete Input
Module, 24 VDC
Positive Logic, 32 points
Lifecycle Status
Active
Active
Active
Active
0-30 VDC
0-15 VDC
0-15 VDC
0-30 VDC
Number of Points
16
16
32
32
Channel to Channel Isolation
No
No
No
No
Input and Output Response
Time- On/Off (ms)
0.5
0.25
0.25
0.5
2 groups of 8
2 groups of 8
4 groups of 8
2 groups of 8
On State Current
2.0-5.5 mA
1.45 mA minimum
1.45 mA minimum
2.0-5.5 mA
Off State Current
0-0.5 mA
0-0.7 mA maximum
0-0.7 mA maximum
0-0.5 mA
10 kOhms maximum
2.4 kOhms at 12 VDC, typical
2.4 kOhms at 12 VDC, typical
10 kOhms maximum
25 maximum
70 maximum
140 maximum
50 maximum
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
One LED per point shows
individual point ON/OFF status.
OK LED indicates backplane
power is present
Input Voltage
Points per Common
Input Impedance
5V Backplane Current
Consumption (mA)
LED Indicators
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x 110 mm (4.3 in) x 66.8 mm (2.63 in) x 110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the 50 mm (1.956 in), not including the 50 mm (1.956 in), not including the
height of the carrier or the
height of the carrier or the
height of the carrier or the
mating connectors
mating connectors
mating connectors
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Dimensions (W x H x D)
3.20
Industrial I/O
VersaMax I/O
Discrete Output Modules
Discrete output modules send control signals to devices such as contactors, indicator lamps, and
interposing relays that can also have two states. Modules require a carrier base (IC200CHSxxx).
IC200MDL329
IC200MDL330
IC200MDL331
Product Name
VersaMax Discrete Output Module,
120 VAC, 0.5A per point Isolated,
8 points
VersaMax Discrete Output Module,
120 VAC 0.5A per point Isolated,
16 points
VersaMax Discrete Output Module,
120 VAC 2.0A per point Isolated,
8 points
Lifecycle Status
Active
Active
Active
85-132 VAC (47-63 Hz), 120 VAC nominal
85-132 VAC (47-63 Hz), 120 VAC nominal
85-132 VAC (47-63 Hz), 120 VAC nominal
8
16
8
Yes
Yes
Yes
0.5 A per point
0.5 A per point
2.0 A per point
<1/2 cycle/<1/2 cycle
<1/2 cycle/<1/2 cycle
<1/2 cycle/<1/2 cycle
Snubber and MOVs (each output)
Snubber and MOVs (each output)
Snubber and MOVs (each output)
8 groups of 1
Isolated points
Isolated points
85-132 VAC (47-63 Hz), 120 VAC nominal
85-132 VAC (47-63 Hz), 120 VAC nominal
85-132 VAC (47-63 Hz), 120 VAC nominal
10 mA minimum per point,
0.5 A maximum per point,
5.0 A for one cycle (20 ms)
maximum inrush
10 mA minimum per point,
0.5 A maximum per point,
5.0 A for one cycle (20 ms)
maximum inrush
10 mA minimum per point,
2.0 A maximum per point,
20 A for one cycle (20 ms)
maximum inrush
70 maximum
140 maximum
85 maximum
One LED per point shows individual
point ON/OFF status (logic side).
OK LED indicates backplane
power is present
One LED per point shows individual
point ON/OFF status (logic side).
OK LED indicates backplane
power is present
One LED per point shows individual
point ON/OFF status (logic side).
OK LED indicates backplane
power is present
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
Output Voltage
Number of Points
Channel to Channel Isolation
Load Current per Point
Input and Output Response
Time- On/Off (ms)
Protection
Points per Common
External Power Supply
Load Current
5V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.21
VersaMax I/O
Industrial I/O
Discrete Output Modules
Discrete output modules send control signals to devices such as contactors, indicator lamps, and
interposing relays that can also have two states. Modules require a carrier base (IC200CHSxxx).
IC200MDL730
IC200MDL740
IC200MDL741
Product Name
VersaMax Discrete Output Module,
24 VDC Positive Logic 2.0A per point
w/ESCP, 8 points
VersaMax Discrete Output Module,
24 VDC Positive Logic, 0.5A per point,
16 points
VersaMax Discrete Output Module,
24 VDC Positive Logic, 0.5A per point
w/ESCP, 16 points
Lifecycle Status
Active
Active
Active
17.5-30 VDC, 24 VDC nominal
10.2-30 VDC, 12/24 VDC nominal
18-30 VDC, 24 VDC nominal
8
16
16
No
No
No
2.0 A per point
0.5 A per point
0.5 A per point
0.5
0.2/1.0
0.5/0.5
Short circuit protection, overcurrent
protection (each output)
No internal fuses (each output)
Short circuit protection, overcurrent
protection, free-wheeling diodes
(each output)
1 group of 8
1 group of 16
1 group of 16
18-30 VDC, 24 VDC nominal
10.2-30 VDC, 12/24 VDC nominal
18-30 VDC, 24 VDC nominal
2.0 A at 30 VDC maximum (resistive)
per point, 8.0 A max per module
0.5 A at 30 VDC maximum (resistive);
2.0 A inrush maximum for 100 ms
0.5 A at 30 VDC maximum (resistive);
2.0 A inrush maximum for 100 ms
50 maximum
45 maximum
75 maximum
LED Indicators
One LED per point shows individual
point ON/OFF state (logic side).
FLD PWR LED indicates field power is
present. OK LED indicates backplane
power is present.
One LED per point shows individual
point ON/OFF state (logic side).
FLD PWR LED indicates field power is
present. OK LED indicates backplane
power is present.
One LED per point shows individual
point ON/OFF state (logic side).
FLD PWR LED indicates field power is
present. OK LED indicates backplane
power is present.
Dimensions (W x H x D)
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
Output Voltage
Number of Points
Channel to Channel Isolation
Load Current per Point
Input and Output Response
Time- On/Off (ms)
Protection
Points per Common
External Power Supply
Load Current
5V Backplane Current
Consumption (mA)
3.22
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax I/O
Discrete Output Modules
Discrete output modules send control signals to devices such as contactors, indicator lamps, and
interposing relays that can also have two states. Modules require a carrier base (IC200CHSxxx).
IC200MDL742
IC200MDL743
IC200MDL744
Product Name
VersaMax Discrete Output Module,
24 VDC Positive Logic 0.5A with
ESCP, 32 points
VersaMax Discrete Output Module,
5/12/24 VDC Negative Logic, 0.5 A per
point (1 group of 16) 16 points
VersaMax Discrete Output Module,
5/12/24 VDC Negative Logic, 0.5 A per
point (2 groups of 16) 32 points
Lifecycle Status
Active
Active
Active
18-30 VDC, 24 VDC nominal
5/12/24 VDC
5/12/24 VDC
Number of Points
32
16 (1 group of 16)
32 (2 groups of 16)
Channel to Channel Isolation
No
No
No
0.5 A per point
0.5 A per point
0.5 A per point
0.5/0.5
0.2/1.0
0.2/1.0
Short circuit protection, overcurrent
protection, free-wheeling diodes
(each output)
No internal fuse
No internal fuse
2 groups of 16
1 group of 16
2 groups of 16
18-30 VDC, 24 VDC nominal
4.75 to 5.25 VDC, 5 VDC nominal
for 5 VDC-TTL mode; 10.2 to 30 VDC,
12/24 VDC nominal for 12/24 VDC mode
4.75 to 5.25 VDC, 5 VDC nominal
for 5 VDC-TTL mode; 10.2 to 30 VDC,
12/24 VDC nominal for 12/24 VDC mode
0.5 A at 30 VDC maximum (resistive);
2.0 A inrush maximum for 100 ms
25 mA maximum for 5 VDC-TTL mode,
0.5 A at 30 VDC maximum,
2.0 A inrush maximum for 100 ms
for 12/24 VDC mode
25 mA maximum for 5 VDC-TTL mode,
0.5 A at 30 VDC maximum,
2.0 A inrush maximum for 100 ms
for 12/24 VDC mode
150 maximum
70 maximum
140 maximum
LED Indicators
One LED per point shows individual
point ON/OFF state (logic side).
FLD PWR LED indicates field power is
present. OK LED indicates backplane
power is present.
One LED per point shows individual
point ON/OFF state (logic side).
FLD PWR LED indicates field power is
present. OK LED indicates backplane
power is present.
One LED per point shows individual
point ON/OFF state (logic side).
FLD PWR LED indicates field power is
present. OK LED indicates backplane
power is present.
Dimensions (W x H x D)
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
Output Voltage
Load Current per Point
Input and Output Response
Time- On/Off (ms)
Protection
Points per Common
External Power Supply
Load Current
5V Backplane Current
Consumption (mA)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.23
VersaMax I/O
Industrial I/O
Discrete Output Modules
Discrete output modules send control signals to devices such as contactors, indicator lamps, and
interposing relays that can also have two states. Modules require a carrier base (IC200CHSxxx).
IC200MDL750
IC200MDL930
IC200MDL940
Product Name
VersaMax Discrete Output Module,
24 VDC Positive Logic, 0.5A per point,
32 points
VersaMax Discrete Output Module,
Relay 2.0 A per point Isolated
Form A, 8 points
VersaMax Discrete Output Module,
Relay 2.0 A per point Isolated
Form A, 16 points
Lifecycle Status
Active
Active
Active
10.2-30 VDC, 12/24 VDC nominal
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz),
120/240 VAC nominal
0-125 VDC, 5/24/125 VDC nominal;
0-265 VAC (47-63 Hz),
120/240 VAC nominal
Number of Points
32
8
16
Channel to Channel Isolation
No
Yes
Yes
0.5 A per point
2.0 A for 5-265 VAC, 2.0 A for 5-30 VDC,
0.2 A for 31-125 VDC
2.0 A for 5-265 VAC, 2.0 A for 5-30 VDC,
0.2 A for 31-125 VDC
0.2/1.0
10.0/10.0
10.0/10.0
No internal fuses
No internal fuses or snubbers
No internal fuses or snubbers
2 groups of 16
Isolated points
Isolated points
10.2-30 VDC, 12/24 VDC nominal
0-125 VDC, 5/24/125 VDC nominal; 0-265
VAC (47-63 Hz), 120/240 VAC nominal
0-125 VDC, 5/24/125 VDC nominal; 0-265
VAC (47-63 Hz), 120/240 VAC nominal
Output Voltage
Load Current per Point
Input and Output Response
Time- On/Off (ms)
Protection
Points per Common
External Power Supply
Load Current
0.5 A at 30 VDC maximum (resistive); 2.0 A
inrush maximum for 100 ms
10 mA per point minimum; 2.0 A for 5-265
10 mA per point minimum; 2.0 A for 5-265
VAC maximum (resistive); 2.0 A for 5-30 VDC VAC maximum (resistive); 2.0 A for 5-30 VDC
maximum (resistive); 0.2 A for 31-125 VDC
maximum (resistive); 0.2 A for 31-125 VDC
maximum (resistive)
maximum (resistive)
90 maximum
245 maximum
490 maximum
LED Indicators
One LED per point shows individual
point ON/OFF state (logic side).
FLD PWR LED indicates field power is
present. OK LED indicates backplane
power is present.
One LED per point shows individual
point ON/OFF state (logic side).
FLD PWR LED indicates field power is
present. OK LED indicates backplane
power is present.
One LED per point shows individual
point ON/OFF state (logic side).
FLD PWR LED indicates field power is
present. OK LED indicates backplane
power is present.
Dimensions (W x H x D)
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
5V Backplane Current
Consumption (mA)
3.24
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax I/O
Analog Input Modules
Analog input modules receive signals from current and voltage input devices. Modules require a
carrier base (IC200CHSxxx).
IC200ALG230
IC200ALG240
IC200ALG260
IC200ALG261
Product Name
VersaMax Analog Input Module,
12 Bit Voltage/Current,
4 Channels
VersaMax Analog Input Module,
16 Bit Voltage/Current Isolated,
8 Channel
VersaMax Analog Input Module,
12 Bit Voltage/Current,
8 Channel
VersaMax Analog Input Module,
15 Bit Differential Voltage,
8 Channel
Lifecycle Status
Active
Active
Active
Active
±10 VDC or 0-10 VDC
±10 VDC, 4-20 mA
4-20mA, ±10 VDC or 0-10 VDC
±10 VDC
Input Range
Number of Channels
4
8 Channel to channel isolated
8
8
None
Range: 19.5-30 VDC including
ripple; Current consumption: 100
mA maximum plus load currents
None
None
Bipolar mode: 2.5 mV = 8 counts,
Unipolar mode: 2.5 mV = 8 counts
Current mode: 381 nA nominal
Voltage mode: 381 µV nominal
Current mode: 4 µA = 8 counts,
Bipolar mode: 2.5 mV = 8 counts,
Unipolar mode: 2.5 mV = 8 counts
Bipolar mode: 0.3125 mV =
1 counts
0.4 ms
Approximately 20 mS max. @
50 Hz filter frequency
Approximately 16.7 mS max. @
60 Hz filter frequency
0.4 ms
7.5 ms
Accuracy at 25°C
±0.3% typical of full scale,
±0.5% maximum of full scale
±0.1% maximum of full scale
±0.3% typical of full scale,
±0.5% maximum of full scale
±0.3% typical of full scale,
±0.5% maximum of full scale
N/A
Input Impedance
Voltage mode:
126 kOhms maximum,
Current mode:
200 Ohms maximum
Voltage mode:
126 kOhms maximum,
Current mode:
200 Ohms maximum
Voltage mode:
100 kOhms maximum
Input Filter Response
5.0 ms
N/A
5.0 ms
N/A
5V Backplane Current
Consumption (mA)
125 maximum
15 maximum
130 maximum
200 maximum
N/A
120 maximum
N/A
N/A
INT PWR LED indicates
internally-generated field power
is present. OK LED indicates
backplane power is present.
FLD PWR LED indicates the
presence of both logic power
and user power. OK LED
indicates module status.
INT PWR LED indicates
internally-generated field power
is present. OK LED indicates
backplane power is present.
INT PWR LED indicates
internally-generated field power
is present. OK LED indicates
backplane power is present.
External Power Supply
Resolution
Update Rate
3.3V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
www.ge-ip.com
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x 110 mm (4.3 in) x 66.8 mm (2.63 in) x 110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the 50 mm (1.956 in), not including the 50 mm (1.956 in), not including the
height of the carrier or the
height of the carrier or the
height of the carrier or the
mating connectors
mating connectors
mating connectors
GE Intelligent Platforms Control Systems Solutions
3.25
VersaMax I/O
Industrial I/O
Analog Input Modules
Analog input modules receive signals from current and voltage input devices. Modules require a
carrier base (IC200CHSxxx).
IC200ALG262
IC200ALG263
IC200ALG264
Product Name
VersaMax Analog Input Module,
15 Bit Differential Current,
8 Channel
VersaMax Analog Input Module,
15 Bit Voltage,
15 Channel
VersaMax Analog Input Module,
15 Bit Current,
15 Channel
Lifecycle Status
Active
Active
Active
0 to 20mA or 4 to 20mA
±10 VDC
0 to 20mA or 4 to 20mA
Input Range
Number of Channels
8
15
15
None
None
None
4 to 20mA: 0.5micro Amp= 1 count;
0 to 20mA: 0.625micro Amp = 1 count
Bipolar mode: 0.3125 mV = 1 count
4 to 20mA: 0.5micro Amp= 1 count;
0 to 20mA: 0.625micro Amp = 1 count
7.5 ms
7.5 ms
7.5 ms
±0.3% typical of full scale,
±0.5% maximum of full scale
±0.3% typical of full scale,
±0.5% maximum of full scale
±0.3% typical of full scale,
±0.5% maximum of full scale
Current mode:
100 kOhms maximum
Voltage mode:
100 kOhms maximum
Voltage mode:
100 kOhms maximum,
Current mode:
200 Ohms maximum
Input Filter Response
N/A
N/A
24 Hz ±20%
5V Backplane Current
Consumption (mA)
200 maximum
150 maximum
100 maximum
N/A
N/A
N/A
INT PWR LED indicates
internally-generated field power
is present. OK LED indicates
backplane power is present.
INT PWR LED indicates
internally-generated field power
is present. OK LED indicates
backplane power is present.
INT PWR LED indicates
internally-generated field power
is present. OK LED indicates
backplane power is present.
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in) , not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in) , not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in) , not including the
height of the carrier or the
mating connectors
External Power Supply
Resolution
Update Rate
Accuracy at 25°C
Input Impedance
3.3V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
3.26
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax I/O
Analog Output Modules
Analog output modules provide voltage or current signals to analog output devices. Modules
require a carrier base (IC200CHSxxx).
Product Name
Lifecycle Status
IC200ALG320
IC200ALG321
IC200ALG322
VersaMax Analog Output Module,
12 Bit Current, 4 Channel
VersaMax Analog Output Module,
12 Bit 0-10V Voltage, 4 Channel
VersaMax Analog Output Module,
12 Bit ±10V Voltage, 4 Channel
Active
Active
Active
4-20 mA
0-10 VDC
±10 VDC
4
4
4
Range: 18-30 VDC
including ripple;
Current consumption:
160 mA maximum
including load current
Range: 18-30 VDC
including ripple;
Current consumption:
125 mA maximum
Range: 18-30 VDC
including ripple;
Current consumption:
125 mA maximum
4 uA = 8 counts
2.5 mV = 8 counts
5 mV = 16 counts
0.3 ms maximum
0.3 ms maximum
0.3 ms maximum
±0.3% typical of full scale,
±0.5% maximum of full scale
±0.3% typical of full scale,
±0.5% maximum of full scale
±0.3% typical of full scale,
±0.5% maximum of full scale
50 maximum
50 maximum
50 maximum
N/A
N/A
N/A
FLD PWR LED indicates
field power is present.
OK LED indicates backplane
power is present.
FLD PWR LED indicates
field power is present.
OK LED indicates backplane
power is present.
FLD PWR LED indicates
field power is present.
OK LED indicates backplane
power is present.
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
Output Range
Number of Channels
External Power Supply
Resolution
Update Rate
Accuracy at 25°C
5V Backplane Current
Consumption (mA)
3.3V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.27
VersaMax I/O
Industrial I/O
Analog Output Modules
Analog output modules provide voltage or current signals to analog output devices. Modules
require a carrier base (IC200CHSxxx).
Product Name
Lifecycle Status
IC200ALG325
IC200ALG326
IC200ALG327
IC200ALG328
IC200ALG331
VersaMax Analog Output
Module, 13 Bit ±10 VDC or 0 to
10 VDC Voltage, 8 Channel
VersaMax Analog Output
Module, 13 Bit Current,
8 Channel
VersaMax Analog Output
Module, 13 Bit ±10 VDC
or 0 to 10 VDC Voltage,
12 Channel
VersaMax Analog Output
Module, 13 Bit, 0 - 20
mA, 4-20 mA Current, 12
Channel
VersaMax Analog Output
Module, 14 Bit Voltage/
Current 1500 VAC
Isolation, 4 Channel
Active
Active
Active
Active
Active
±10 VDC or 0 to 10 VDC
4 to 20mA (default)
0 to 20mA (configured
with jumper)
±10 VDC or 0 to 10 VDC
4 to 20 mA (default)
0 to 20 mA (configured
with jumper)
±10 VDC, 4-20 mA
8
8
12
12 single ended, one group
4
Range: 18-30 VDC
including ripple;
Current consumption:
102 mA maximum
Range: 18-30 VDC
including ripple;
2A inrush maximum,
100 mA maximum
(no load), 185 mA
maximum (all 8
outputs at full scale)
Range: 18-30 VDC
including ripple;
Current consumption:
112 mA maximum
Range: 18-30 VDC
including ripple;
Current consumption:
2A inrush maximum
100 mA maximum (no load)
270 mA maximum
(all 12 outputs at full scale)
Range: 19.5-30 VDC
including ripple;
Current consumption:
100 mA maximum
plus load currents
1.25 mV = 4 counts
4-20 mA: 5 counts =
2.5 uA (~12.7 bits) 0-20 mA:
4 counts = 2.5 uA (13 bits)
1.25 mV = 4 counts
15.0 ms maximum
15.0 ms maximum
10.0 ms maximum
15 ms maximum
7 ms maximum
±0.3% typical of full scale,
±0.5% maximum of full scale
±0.3% of full scale (typical),
±0.5% of full scale (max)
±1% of full scale (max)
±0.3% typical of full scale,
±0.5% maximum of
full scale
+/- 0.3% of full scale
(typical),
+/- 0.5% of full scale (max.)
+/-1% of full scale (max.)
±0.1% maximum of
full scale
50 maximum
50 maximum
50 maximum
50 maximum
10 maximum
N/A
N/A
N/A
N/A
115 maximum
Output Range
Number of Channels
External Power Supply
Resolution
Update Rate
Accuracy at 25¢XC
5V Backplane Current
Consumption (mA)
3.3V Backplane Current
Consumption (mA)
LED Indicators
Dimensions (W x H x D)
3.28
4-20 mA: 5 counts =
Current mode: 381 nA
2.5 uA (~12.7 bits) 0-20 mA: nominal Voltage mode: 381
4 counts = 2.5 uA (13 bits)
µV nominal
FLD PWR LED indicates
field power is present.
OK LED indicates backplane
power is present.
FLD PWR LED indicates
FLD PWR LED indicates
FLD PWR LED indicates
field power is present.
field power is present.
field power is present.
OK LED indicates backplane OK LED indicates backplane OK LED indicates backplane
power is present.
power is present.
power is present.
FLD PWR LED indicates
the presence of both logic
power and user power.
OK LED indicates
module status.
110 mm (4.3 in) x
66.8 mm (2.63 in) x 50 mm
(1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x
66.8 mm (2.63 in) x 50 mm
(1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x
66.8 mm (2.63 in) x 50 mm
(1.956 in), not including the
height of the carrier or the
mating connectors
GE Intelligent Platforms Control Systems Solutions
110 mm (4.3 in) x
66.8 mm (2.63 in) x 50 mm
(1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x
66.8 mm (2.63 in) x 50 mm
(1.956 in), not including the
height of the carrier or the
mating connectors
www.ge-ip.com
Industrial I/O
VersaMax I/O
Analog Mixed Modules
Analog mixed modules provide maximum flexibility by combining inputs and outputs in a single,
compact module. Modules require a carrier base (IC200CHSxxx).
IC200ALG430
IC200ALG431
IC200ALG432
Product Name
VersaMax Analog Mixed Module,
12 Bit Input Current 4 Channel/Output
Current 2 Channel
VersaMax Analog Mixed Module,
12 Bit 0-10V Input 4 Channel/Output
0-10V 2 Channel
VersaMax Analog Mixed Module,
12 Bit ±10V Input 4 Channel/Output
±10V 2 Channel
Lifecycle Status
Active
Active
Active
4-20 mA
0-10 VDC
-10 to +10 VDC
Input Range
Output Range
4-20 mA
0-10 VDC
-10 to +10 VDC
Range: 18-30 VDC including ripple;
Current consumption: 125 mA maximum
Range: 18-30 VDC including ripple;
Current consumption: 125 mA maximum
Range: 18-30 VDC including ripple;
Current consumption: 125 mA maximum
4 uA = 8 counts
2.5 mV = 8 counts
Input: 2.5 mV = 8 counts,
Output: 5 mV = 16 counts
0.3 ms maximum
0.3 ms maximum
0.3 ms maximum
Accuracy at 25°C
±0.3% typical of full scale,
±0.5% maximum of full scale
±0.3% typical of full scale,
±0.5% maximum of full scale
±0.3% typical of full scale,
±0.5% maximum of full scale
Input Impedance
200 Ohms maximum
120 kOhms minimum
125 kOhms minimum
5.0 ms
5.0 ms
5.0 ms
FLD PWR LED indicates field power
is present. OK LED indicates backplane
power is present.
FLD PWR LED indicates field power
is present. OK LED indicates backplane
power is present.
FLD PWR LED indicates field power is
present. OK LED indicates backplane
power is present.
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x
50 mm (1.956 in), not including the
height of the carrier or the
mating connectors
External Power Supply
Resolution
Update Rate
Input Filter Response
LED Indicators
Dimensions (W x H x D)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.29
VersaMax I/O
Industrial I/O
RTD and Thermocouple Modules
Specialty modules are available for RTD and Thermocouple inputs. Modules require a carrier base
(IC200CHSxxx).).
IC200ALG620
IC200ALG630
Product Name
VersaMax Analog Input Module,
16 Bit RTD, 4 Channel
VersaMax Analog Input Module,
16 Bit Thermocouple, 7 Channel
Lifecycle Status
Active
Active
RTD types: 25, 100, and 1000 ohm platinum
10, 50, and 100 ohm copper 100 and
120 ohm nickel 604 ohms nickel/iron
Thermocouple types:
J, K, T, S, R, none (used for mV inputs)
4
7
15 bits plus sign
15 bits plus sign
60 Hz: approximately 210 milliseconds per channel 50 Hz:
approximately 230 milliseconds per channel
60 Hz: approximately 60 milliseconds per channel 50 Hz:
approximately 70 milliseconds per channel
on voltage measurement: ±0.15% on resistance measurement
on temperature measurement: ±0.15% on RTD
(temperature) measurement
on voltage measurement: ±0.2%
on temperature measurement:±0.15%
5 V Backplane Current
Consumption (mA)
125 maximum
125 maximum
3.3 V Backplane Current
Consumption (mA)
125 maximum
125 maximum
LED Indicators
OK LED: green indicates backplane power is present.
Amber indicates module fault.
OK LED: green indicates backplane power is present.
Amber indicates module fault.
Dimensions (W x H x D)
110 mm (4.3 in) x 66.8 mm (2.63 in) x 50 mm (1.956 in),
not including the height of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm (2.63 in) x 50 mm (1.956 in),
not including the height of the carrier or
the mating connectors
Input Range
Number of Channels
Resolution
Update Rate
Accuracy at 25°C
3.30
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax I/O
Specialty Modules
Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a
single, compact module. Discrete input modules receive signals from input devices such as
sensors, pushbuttons, and switches that can have two states: on or off, open or closed.
Discrete output modules send control signals to devices such as contactors, indicator
lamps, and interposing relays that can also have two states. Discrete mixed modules provide maximum flexibility by combining inputs and outputs in a single, compact module.
Modules require a carrier base (IC200CHSxxx).
IC200MDD841
Product Name
VersaMax Discrete Mixed Modules 24VDC Pos Logic
Input 20/Output 12/HSC, PWM or Pulse Train
Lifecycle Status
Active
Input Voltage
24 VDC
Output Voltage
24 VDC
Number of Points
Channel to Channel Isolation
Inrush Current
Input and Output Response
Time- On/Off (ms)
Protection
On State Current
Off State Current
External Power Supply
Input Impedance
Load Current
5V Backplane Current
Consumption (mA)
20 in/12 out/4 configurable
No
2.0 A maximum for 100 ms
7 and 0.5
No internal fuses
3.0-8.0 mA
0-0.5 mA
24 VDC nominal, 18-30 VDC
9.6 kOhms maximum
0.5 A maximum
30
LED Indicators
One LED per point shows individual point on/off state (logic side);
OK LED indicates backplane power is present
Dimensions (W x H x D)
110 mm (4.3 in) x 66.8 mm (2.63 in) x 50 mm (1.956 in),
not including the height of the carrier or the mating connectors
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.31
VersaMax I/O
Industrial I/O
Expansion Modules
Expansion Modules can be used to extend a VersaMax PLC or I/O station to include up to
seven additional groups of up to eight modules each, providing the architectural flexibility to
accommodate larger applications.
IC200ERM001
IC200ERM002
IC200ETM001
Product Name
Expansion Receiver Module,
Isolated
Expansion Receiver Module,
Non-Isolated
Bus Transmitter Expansion Module
Lifecycle Status
Active
Active
Active
Expansion Type
Receiver
Receiver
Transmitter
Up to 2460 feet
Up to 50 feet
N/A
5 V Backplane Current
Consumption (mA)
430
70
44
3.3 V Backplane Current
Consumption (mA)
20
20
N/A
LED Indicators
PWR LED indicates 5 VDC power status;
EXP RX LED indicates status of the
expansion bus; SCAN indicates whether
CPU/NIU is scanning I/O in
expansion racks
PWR LED indicates 5 VDC power status;
EXP RX LED indicates expansion
bus communications status;
SCAN indicates whether CPU/NIU
is scanning I/O in expansion racks
PWR LED indicates 5 VDC power status;
EXP TX LED indicates expansion
bus communication status
Dimensions (W x H x D)
2.63 (66.8 mm) x 5.04 (128 mm)
not including the height of power supply
2.63 (66.8 mm) x 5.04 (128 mm)
not including the height of power supply
37 mm (1.45 in) x 5.04 (128 mm)
Distance
3.32
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax I/O
Remote I/O Units
A Remote I/O Unit connects VersaMax I/O modules to a host PLC or computer via a variety
of networks. This makes it easy to include VersaMax I/O in the innovative PROFINET
interface, as well as Genius, Profibus-DP, DeviceNet, or other Ethernet installations.
Together, the Remote I/O Unit and its modules form an I/O station capable of providing
up to 256 points of I/O.
IC200PNS001
IC200PNS002
IC200DBI001
IC200EBI001
Product Name
Remote I/O PROFINET Network
Interface Unit (Cooper Media)
with built-in switch
Bus Transmitter Expansion
Module (Fiber Media)
with built-in switch
Remote I/O DeviceNet
Network Interface Unit (Slave)
Remote I/O Ethernet
Network Interface Unit
Lifecycle Status
Active
Active
Active
Active
PROFINET Slave,
Version 2.2 Class A IO-Device
PROFINET Slave,
Version 2.2 Class A IO-Device
DeviceNet Slave
EGD and Modbus TCP Server
100 Meters max drop length
10/100Mbaud
2 – 2,000 (Full-Duplex) 2 – 400
(Half-Duplex)
500Kbps 100m bus length and
branches totaling < 39m
250Kbps 250m bus length and
branches totaling < 78m
125Kbps 500m bus length and
branches totaling < 156m
100 Meters max drop length
10/100Mbaud
2880 bytes total
1440 bytes of input data
1440 bytes of output data
2880 bytes total
1440 bytes of input data
1440 bytes of output data
Includes both discrete and analog.
Up to 128 bytes of inputs + 2-byte
status word Up to 128 bytes of
outputs + 2-byte control word.
1024 bytes maximum both
discrete and analog. %I: 2048
points %Q: 2048 points
2880 bytes total
1440 bytes of input data
1440 bytes of output data
2880 bytes total
1440 bytes of input data
1440 bytes of output data
Includes both discrete and analog.
Up to 128 bytes of inputs + 2-byte
status word Up to 128 bytes of
outputs + 2-byte control word.
1024 bytes maximum both
discrete and analog. %AI: 128
channels %AQ: 128 channels
N/A
N/A
Up to 128 bytes of inputs + 2-byte
status word Up to 128 bytes of
outputs + 2-byte control word.
256 Bytes of input, output,
Analog input and Analog output
Configurable: 1ms, 2ms, 4ms,
8ms, 16ms, 32ms, 64ms, 128ms,
256ms and 512ms
Configurable: 1ms, 2ms, 4ms,
8ms, 16ms, 32ms, 64ms, 128ms,
256ms and 512ms
N/A
N/A
Daisy-chain/line, star, or ring
(redundant media) topology.
Daisy-chain/line, star, or ring
(redundant media) topology.
Linear bus (trunkline/dropline);
power and signal on the same
network cable
Network dependent
10/100BASE-T
Fiber 100BASE-FX
Shielded, dual twisted pair cable,
terminated at both ends
Ethernet twisted pair
(2) RJ45 with
built-in switch
(2) SC or SC-Duplex with
built-in switch
5-pin open
pluggable connector
RJ-45
32 input status bits and
32 output control bits
32 input status bits and
32 output control bits
2 bytes of status/control
4
8 per NIU/station,
not expandable
8 per NIU/station,
not expandable
8 per NIU/station
8 per NIU/station
No
No
N/A
No
3 Watts
5 Watts
160
175
N/A
N/A
10
425
134mm (5.28 in) x
132mm (5.2 in)
134mm (5.28 in) x
132mm (5.2 in)
133.4 mm (5.25 in) x
85.9 mm (3.38 in) not including
the height of power supply
133.4 mm (5.25 in) x
85.9 mm (3.38 in) not including
the height of power supply
Protocol Supported
Distance
I/O Discrete Points
I/O Analog Words
I/O Data
I/O Data Update Rate
Network Topology
Transmission Media
Connector
User Diagnostic Data
Number of Modules
Redundancy
5V Backplane Current
Consumption (mA)
3.3V Backplane Current
Consumption (mA)
Dimensions (W x H x D)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.33
VersaMax I/O
Industrial I/O
Remote I/O Units
A Remote I/O Unit connects VersaMax I/O modules to a host PLC or computer via a variety
of networks, which makes it easy to include VersaMax I/O in Genius, Profibus-DP, DeviceNet,
or Ethernet installations. Together, the Remote I/O Unit and its modules form an I/O station
capable of providing up to 256 points of I/O.
IC200GBI001
IC200PBI001
Genius Network Interface Unit
Remote I/O Profibus-DP Network
Interface Unit (Slave)
Active
Active
Genius
Profibus DP
1372 to 2286 meters - 38.4 Kbaud supports a
maximum of 16 devices. 1067 to 1372 meters
76.8 Kbaud supports a maximum of 32 devices.
609 to 1067 meters - 153. 6 Kbaud extended supports
a maximum of 32 devices. Less than 609 meters
153.6 Kbaud standard or 153.6 Kbaud extended
supports a maximum of 32 devices.
9.6Kbits - 1,200 meters
19.2Kbits - 1,200 meters
93.75Kbits - 1,200 meters
187.5Kbits - 600 meters
500Kbits - 400 meters
1.5Mbits - 200 meters
3Mbits; 6Mbits; 12Mbits - 100 meters
1024 Inputs and 1024 Outputs
375 bytes maximum. Up to 244 bytes
of inputs or 244 bytes of outputs
64 Analog In and 64 Analog Out
375 bytes maximum. Up to 244 bytes
of inputs or 244 bytes of outputs
128 bytes in and 128 out per bus scan
375 bytes maximum. Up to 244 bytes
of inputs or 244 bytes of outputs.
N/A
N/A
Bus
Linear bus, terminated at both ends.
Stubs are possible.
Shielded, twisted pair, fiber optic (external option)
Shielded, twisted pair cable
Removable Connector
9-pin D-sub connector
Yes
2 bytes of status/control, 5 bytes of
standard Profibus diagnostics
8 per NIU/station
8 per NIU/station
Full media and hardware redundancy supported
N/A
5V Backplane Current
Consumption (mA)
250
250
3.3V Backplane Current
Consumption (mA)
10
10
133.4 mm (5.25 in) x 85.9 mm (3.38 in)
not including the height of power supply
133.4 mm (5.25 in) x 85.9 mm (3.38 in)
not including the height of power supply
Product Name
Lifecycle Status
Protocol Supported
Distance
I/O Discrete Points
I/O Analog Words
I/O Data
I/O Data Update Rate
Network Topology
Transmission Media
Connector
User Diagnostic Data
Number of Modules
Redundancy
Dimensions (W x H x D)
3.34
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax I/O
Network Interface Modules
Network Interface Modules allow a VersaMax PLC to operate as a master or slave on a network. Modules currently available support DeviceNet master or slave communications and
Profibus-DP slave communications. An AS-i master communications is also available.
IC200BEM002
IC200BEM103
IC200BEM104
IC200CHS006
Product Name
PLC Network Communications
Profibus-DP (Slave).
Requires IC200CHS006
Communications Carrier.
PLC Network Communications
DeviceNet (Master).
Requires IC200CHS006
Communications Carrier.
PLC Network Communications
AS-i (Master).
Requires IC200CHS006
Communications Carrier.
VersaMax I/O, Local
Communications Carrier
(Supports IC200BEMxxx Modules)
Lifecycle Status
Active
Active
Active
Active
32 without repeaters;
up to 125 with repeaters
N/A
N/A
N/A
384 Bytes maximum; up to
244 bytes of inputs or
244 bytes of outputs
Up to 128 bytes of inputs
and 128 bytes of outputs
4 input bits and
4 output bits per slave
N/A
Network Data Rate
9.6 Kbaud to 12 Mbaud
125 Kbaud, 250 Kbaud, 500 Kbaud
166.6Kbits/second
N/A
Linear bus, terminated at both
ends. Stubs are possible
Linear bus (trunkline/ dropline);
power and signal on the same
network cable
Tree Structure
N/A
Network Topology
Shielded, twisted pair cable
Shielded, dual twisted pair cable
Rubber coated two wire cable
N/A
9-pin D-sub connector
5-pin open pluggable connector
Box Style
N/A
Number of Nodes
N/A
Supports up to 40 slave devices
Supports up to 31 slave devices
N/A
User Diagnostic Data
N/A
One presence bit per slave device
Display data
N/A
460 mA maximum from
5 V output, 5 mA from
+3.3 V output
490 mA maximum from
5 V output, 2 mA from
+3.3 V output
350 mA maximum from
5 V output
N/A
Power Consumption
110 mm (4.3 in) x 66.8 mm
(2.63 in) x 50 mm (1.956 in),
not including the height
of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm
(2.63 in) x 50 mm (1.956 in),
not including the height
of the carrier or the
mating connectors
110 mm (4.3 in) x 66.8 mm
(2.63 in) x 50 mm (1.956 in),
not including the height
of the carrier or the
mating connectors
66.8 mm (2.63 in) x 133.4 mm
(5.25 in) x 70 mm (2.75 in),
not including the height
of DIN Rail
Number of Stations
I/O Data
Transmission Media
Connector
Dimensions (W x H x D)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.35
VersaMax I/O
Industrial I/O
Serial Communications
The serial communications expansion module provides a Modbus Master port for a Genius
NIU remote I/O drop. The serial port can be used to interface with a wide range of Modbus
slave devices such as controllers, VFDs, bar code readers, marques and much more. The
data is transferred to and from the NIU over the Genius LAN and is compatible with any
controller that supports Genius Global Data.
IC200CMM020
Product Name
Modbus Master Module, 1 RS-485 port.
Requires IC200CHS006 Communications Carrier.
Lifecycle Status
Active
Module Type
NIU Type Supported
Number of Serial Communications
Modules
Modbus Master
Genius and Profinet Slave
Up to 2 per Genius NIU I/O Station
Number of RTU slaves per
Serial Communications Module
Serial Port Type
Baud Rate Supported
1 to 247
RS-485. 15-pin subminiature ‘D’ connector. For RS-232
communications, an RS-485 to RS-232 adapter such as
IC690ACC901 can be used. Adapter IC690ACC901 can be
installed with its right-angle cable hanging down.RS-485
supports both 2-wire and 4-wire electrical interfaces
1200, 2400, 4800, 9600, and 19200,
and half or full duplex operation
COMMREQ command memory (%AQ)
required in the GENERIC_COMM module
hardware configuration
Depends on individual COMMREQ content.
Minimum: 22 words Maximum: 64 words
RTU Master Commands
65520, Initialize RTU Master Port
8000, Clear RTU Master Diag. Status
8001, Read RTU Master Diag. Status
8002, Send RTU Read/Force/Preset Query
8003, Send RTU Diagnostic Query
Power Consumption
Dimensions (W x H x D)
3.36
460 mA maximum from 5 V output,
5 mA from +3.3 V output
110mm (4.3in) x 66.8mm (2.63in) x 50mm (1.956 in),
not including the height of the carrier
or the mating connectors
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax I/O
Accessories
IC200ACC001
Replacement Battery for VersaMax CPUs
Active
IC200ACC003
EZ Program Store, CPU RS-485 Port Update Device
Active
IC200ACC201
Expansion Terminator QTY 1
Active
IC200ACC202
Expansion Terminator QTY 2
Active
IC690ACC905
Encapsulated Thermistor Kit QTY 2
Active
IC200ACC301
I/O Filler Module
Active
IC200ACC302
I/O Input Simulator
Active
IC200ACC303
I/O Shorting Bar QTY 2
Active
IC200ACC304
Cable Connector Kit, QTY 2, for connector base (IC200CHS003) I/O Base (IC200CHS011, CHS012, CHS014, CHS015
and CHS1xx bases)
Active
IC200ACC313
DIN rail clips (Qty 2) to secure modules on DIN rail
Active
IC200TBM001
I/O Auxiliary Terminal Strip, 18 Internally Bussed, Barrier Style
Active
IC200TBM002
I/O Auxiliary Terminal Strip, 18 Internally Bussed, Box Style
Active
IC200TBM005
I/O Auxiliary Terminal Strip, 18 Internally Bussed, Spring Clamp Style
Active
Cables for Connector Type Carrier
IC200CBL105
Cable, I/O Non-Shielded, 2 Connectors. 0.5M used with IC200CHS003 and IC200CHS011, 012, 015.
Active
IC200CBL110
Cable, I/O Non-Shielded, 2 Connectors, 1.0M used with IC200CHS003 and IC200CHS011, 012, 015.
Active
IC200CBL120
Cable, I/O Non-Shielded, 2 Connectors, 2.0M used with IC200CHS003 and IC200CHS011, 012, 015.
Active
IC200CBL230
Cable, I/O Non-Shielded, 1 Connector, 3.0M used with IC200CHS003 and IC200CHS011, 012, 015.
Active
Cables to Connect Rack to Rack Expansion
IC200CBL600
Rack Expansion Cable, Shielded, Single Ended, 1M to One Expansion Receiver Module (IC200ERM00x)
Active
IC200CBL601
Rack Expansion Cable, Shielded, 2 Connectors, 1M. Supports Multidrop to Multiple Expansion Receiver Modules (IC200ERM00x)
Active
IC200CBL602
Rack Expansion Cable, Shielded, 2 Connectors, 2M. Supports Multidrop to Multiple Expansion Receiver Modules (IC200ERM00x)
Active
IC200ACC304
Cable Connector Kit, QTY 2, for connector base (IC200CHS003) I/O Base (IC200CHS011, CHS012, CHS014, CHS015 and CHS1xx bases)
Active
IC200PKG001
PLC Starter Kit CPU001
Contains CPU001, PWR101, MDD845, CHS002, ACC302, CBL001, GFK-1503, GFK-1504, 641VPS300
(Infolink included), coffee mug, and plastic carry case. Does not include 24 VDC power supply for inputs.
Active
IC200PKG010
PLC Starter Kit CPUE05
Contains CPUE05, PWR101, MDD845, CHS002, ACC302, CBL001, GFK-1503, GFK-1504, Machine Edition
(Infolink included), coffee mug, and plastic carry case. Does not include 24 VDC power supply for inputs.
Active
IC200PKG101
I/O Starter Kit GENIUS
Contains GBI001, PWR101, MDD845, CHS002, ACC302, CBL001, GFK-1535, GFK-1504, 690CDR002
(Infolink), coffee mug, and plastic carry case. Does not include 24 VDC power supply for inputs.
Active
IC200PKG102
I/O Starter Kit Profibus-DP
Contains PBI001, PWR101, MDD845, CHS002, ACC302, CBL001, GFK-1534, GFK-1504, 690CDR002
(Infolink), coffee mug, and plastic carry case. Does not include 24 VDC power supply for inputs.
Active
IC200PKG103
I/O Starter Kit DeviceNet
Contains DBI001, PWR101, MDD845, CHS002, ACC302, CBL001, GFK-1533, GFK-1504, 690CDR002
(Infolink), coffee mug, and plastic carry case. Does not include 24 VDC power supply for inputs.
Active
IC200PKG104
I/O Starter Kit Ethernet
Contains EBI001, PWR101, MDD845, CHS002, ACC302, CBL001, GFK-1534, GFK-1504, Machine Edition
(Infolink), coffee mug, and plastic carry case. Does not include 24 VDC power supply for inputs.
Active
Starter Kits
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.37
VersaMax I/O
Industrial I/O
Configuration Guidelines
When configuring a VersaMax Modular the following guidelines should be considered:
For a multiple-rack expansion system, connect the cable from the expansion port on the
Expansion Transmitter to the Expansion Receivers as shown below. If all the Expansion
Receivers are the Isolated type (IC200ERM001), the maximum overall cable length is 750
meters. If the expansion bus includes any non-isolated Expansion Receivers (IC200ERM002),
the maximum overall cable length is 15 meters.
1. All I/O modules require an I/O Carrier (IC200CHS001, 002, 003, 005, 022 or 025).
VersaMax PLC or I/O Station Main Rack (0)
2. When an I/O Connector Carrier (IC200CHS003) is selected, a cable (IC200CBL6xx)
and interposing remote base (IC200CHS011, 012, 014 or 015) are required.
3. When configuring a system, the power consumptions should be tracked to
determine what power supply and how many power supplies may be required.
VersaMax Expansion Rack 1
4. DIN rail clips should be used to secure the VersaMax modules (IC200ACC313).
15M with any IC200ERM002 ERMs
5. A maximum of 8 carriers, any combination of I/O or communications, can be
connected directly to either an NIU or CPU. (Power Supply Booster base is not
counted as a carrier). CPUs and NIUs can be expanded beyond the 8 carriers
using the Bus Transmitter Expansion (IC200ETM001) and up to 7 Expansion
Receiver Modules (IC200ERM00x) for a total of 64 carrier modules.
750M with all IC200ERM001 ERMs
IC200CBL601,
602, 615
VersaMax Expansion Rack 7
Terminator
Plug
Install the Terminator Plug (supplied with the Expansion Transmitter module) into the lower port
on the last Expansion Receiver. Spare Terminator Plugs can be purchased separately as part
number IC200ACC201 (Qty 2).
Examples of Typical Application
Configuration for Controller (Example application requiring (30) 24 VDC inputs and (10) Relay outputs AC power supply)
Power Supply Current Required (mA)
Qty
Part Number
[email protected] 5 V and [email protected] 3 V
1
IC200CPU001
VersaMax PLC CPU 32K Configurable Memory, 2 Ports RS-232 and RS-485
1
IC200PWR101
VersaMax 120/240 VAC Power Supply (1.5 amps 5 V and 0.25 amps 3.3 V)
50 @ 5 V
1
IC200MDL650
VersaMax Discrete Input Module, 24 VDC Positive Logic, 32 points
490 @ 5 V
1
IC200MDL940
VersaMax Discrete Output Module, Relay 2.0 A per point Isolated Form A, 16 points
2
IC200CHS022
VersaMax Compact I/O Carrier, Local Box Clamp Connection Style
Total:
Description
1
IC200ACC313
DIN rail clips (Qty 2) to secure modules on DIN rail
1
IC646MPS101
Logic Developer - PLC Standard - w/Programming Cable
580 @ 5 V and 100 @ 3 V (820 mA remaining). 1500 mA available for 5 V and 3.3 V.
Options to consider
100 @ 5 V
1
IC690PWR024
24 VDC, 5 Amp Output Power and 120/230 VAC Input Power Power Supply
1
IC200ACC003
EZ Program Store, CPU RS485 Port Update Device
Configuration for Controller (Application requiring 20K of Registers, (60) 24 VDC inputs, (15) AC Inputs, (12) AC Outputs and (20) Relay outputs also (16) Analog Inputs,
(12) Isolated Analog Outputs and 24 VDC power supply. Also requires Profibus Slave connection)
Power Supply Current Required
Qty
Part Number
Description
80 @ 5 V and 650 @ 3 V
1
IC200CPU005
VersaMax PLC CPU 128K Configurable User Memory, 2 Ports RS-232 and RS-485
3
IC200PWR002
24 VDC Power Supply with Expanded 3.3 V (Logic side supply of 1.5 amps maximum.
Up to 1.0 amp can be allocated for 3.3 V usage.)
100 @ 5 V
2
IC200MDL650
VersaMax Discrete Input Module, 24 VDC Positive Logic, 32 points
110 @ 5 V
1
IC200MDL240
VersaMax Discrete Input Module, 120 VAC Positive Logic, 16 points
170 @ 5 V
2
IC200MDL331
VersaMax Discrete Output Module, 120 VAC 2.0 A per point Isolated, 8 points
980 @ 5 V
2
IC200MDL940
VersaMax Discrete Output Module, Relay 2.0 A per point Isolated Form A, 16 points
400 @ 5 V
2
IC200ALG262
VersaMax Analog Input Module, 15 Bit Differential Current, 8 Channel
10 @ 5 V and 115 @ 3 V
2
IC200ALG331
VersaMax Analog Output Module, 14 Bit Voltage/Current 1500 VAC Isolation, 8 Channel
11
IC200CHS022
VersaMax Compact I/O Carrier, Local Box Clamp Connection Style
460 @ 5 V and 5 @ 3 V
1
IC200BEM002
PLC Network Communications Profibus-DP (Slave)
1
IC200PWB001
VersaMax Power Supply Booster Carrier. Supplies power to all modules to the right of
booster. Requires power supply.
IC200CHS006
VersaMax I/O, Local Communications Carrier
44 @ 5 V
1
IC200ETM001
Bus Transmitter Expansion Module
70 @ 5 V and 20 @ 3 V
1
IC200ERM002
Expansion Receiver Module, Non-Isolated
1
IC200CBL600
Cable Expansion Shielded Single Ended 1M
Total:
1
IC200ACC313
DIN rail clips (Qty 2) to secure modules on DIN rail
1
IC646MPS101
Logic Developer - PLC Standard - w/Programming Cable
2424 @ 5 V and 790 @ 3 V Required. 4500 mA available for 5 V and 3.3 V. Power Supply to meet power requirements.
(continued on next page)
3.38
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax I/O
Options to consider
100 @ 5 V
1
IC690PWR024
24 VDC, 5 Amp Output Power and 120/230 VAC Input Power Power Supply
1
IC754VSI06STD
QuickPanel View Intermediate 6 inch STN Touch DC
1
IC200ACC003
EZ Program Store, CPU RS485 Port Update Device
Configuration for Controller Ethernet connectivity, (60) 24 VDC inputs, (20) Relay outputs, (16) Analog Inputs, (12) Thermocouples on a remote Ethernet drop, (12)
Isolated Analog Outputs and 24 VDC power supply. Also requires Color TFT Operator Interface with Touch Screen.
Power Supply Current Required
Qty
Part Number
Description
160 @ 5 V and 650 @ 3 V
1
IC200CPUE05
VersaMax PLC CPU 128K Configurable User Memory, 2 Ports RS-232 and RS-485, 10
MBIT Ethernet Port. Supports SRTP and EGD.
2
IC200PWR002
24 VDC Power Supply with Expanded 3.3 V (Logic side supply of 1.5 amps maximum.
Up to 1.0 amp can be allocated for 3.3 V usage.)
1
IC200PWB001
VersaMax Power Supply Booster Carrier. Supplies power to all modules to the right of
booster. Requires power supply.
100 @ 5 V
2
IC200MDL650
VersaMax Discrete Input Module, 24 VDC Positive Logic, 32 points
980 @ 5 V
2
IC200MDL940
VersaMax Discrete Output Module, Relay 2.0 A per point Isolated Form A, 16 points
400 @ 5 V
2
IC200ALG262
VersaMax Analog Input Module, 15 Bit Differential Current, 8 Channel
10 @ 5 V and 115 @ 3 V
2
IC200ALG331
VersaMax Analog Output Module, 14 Bit Voltage/Current 1500 VAC Isolation, 8 Channel
8
IC200CHS022
VersaMax Compact I/O Carrier, Local Box Clamp Connection Style
2
IC200ACC313
DIN rail clips (Qty 2) to secure modules on DIN rail
1
IC646MBT001
Logic Developer PLC Standard Edition and View for QuickPanel with 15 mos. of Proficy
GlobalCare which is renewable on an annual basis.
1
IC754VSI06STD
QuickPanel View Intermediate 6 inch STN Touch DC
Total:
1650 @ 5 V and 765 @ 3 V. 3000 mA available for 5 V and 3.3 V.
Ethernet Remote Drop
175 @ 5 V and 425 @ 3 V
250 @ 5 V and 250 @ 3 V
Total:
1
IC200ETM001
Bus Transmitter Expansion Module
1
IC200PWR002
24 VDC Power Supply with Expanded 3.3 V (Logic side supply of 1.5 amps maximum.
Up to 1.0 amp can be allocated for 3.3 V usage.)
2
IC200ALG630
VersaMax Analog Input Module, 16 Bit Thermocouple, 7 Channel
1
IC690ACC905
Encapsulated Thermistor Kit Qty 2
2
IC200CHS022
VersaMax Compact I/O Carrier, Local Box Clamp Connection Style
1
IC200ACC313
DIN rail clips (Qty 2) to secure modules on DIN rail
2424 @ 5 V and 790 @ 3 V Required. 4500 mA available for 5 V and 3.3 V. Power Supply Booster required with extra
Power Supply to meet power requirements.
Options to consider
100 @ 5 V
www.ge-ip.com
1
IC690PWR124
24 VDC, 10 Amp Output Power and 120/230 VAC Input Power Power Supply
1
IC200ACC003
EZ Program Store, CPU RS485 Port Update Device
GE Intelligent Platforms Control Systems Solutions
3.39
Genius I/O
Industrial I/O
Genius Distributed I/O
By providing distributed control on
the factory floor, Genius I/O systems
offer fewer terminations to document,
dramatically shorter wiring runs, and
simpler, more effective troubleshooting. Genius I/O blocks automatically
provide diagnostic information on field
wiring, power conditions and loads,
as well as the state of the communication network, blocks and circuits.
Genius diagnostics sharply reduce
the time needed for initial control
and debugging.
Genius blocks provide predictable
­system operation in the event of a
CPU, bus interface or network cable
AC Discrete I/O Modules
page 3.41
DC Discrete I/O Modules
pages 3.42-3.43
Analog Input Modules
page 3.44
Analog Output Modules
page 3.45
Analog Mixed Modules
page 3.46
RTD and Thermocouple Modules
page 3.47
High Speed Counter
page 3.48
PowerTRAC Monitoring Module
page 3.49
Accessories
page 3.50
Configuration Guidelines
failure. When connected in a redundant ­configuration with two or more
CPUs running simultaneously, the
Genius blocks will shift automatically
to a backup CPU if the main controller
fails to communicate.
Genius blocks communicate with
the system CPU over the Genius LAN,
greatly simplifying system installation,
and with network tools such as the
hand-held monitor, troubleshooting
is a snap. In addition to Genius I/O
blocks, VersaMax I/O may also be
­integrated into a single Genius LAN.
pages 3.51-3.52
Publication Reference Chart
GEK-90486D I/O Discrete and Analog Blocks
GEK-90486F-1 I/O System and Communications
GFK-0074A
Genius I/O PCIM User’s Manual
GFK-0415E
High Speed Counter
GFK-0450DPowerTRAC
GFK-0881
Single Slot Personal Computer Interface
Module (PCIM)
GFK-1179J
Installation Requirements for
Conformance to Standards
3.40
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
Genius I/O
AC Discrete I/O Modules
Control power for the block is tapped off the input/output device voltages wired to the­
terminals. No separate block power supply is needed. Configurable features include;
Output Pulse Test capability, Selectable Input Filter Time from 10mS to 100mS, Output
powerup defaults, Output Hold Last State or default, each circuit has electronic fusing.
IC660BBD110
IC660BBD101
IC660BBS102
IC660BBS103
IC660BBR100
IC660BBR101
Genius Discrete
Input Block,
115 VAC Grouped,
16 Point
Genius Discrete
I/O Block,
115 VAC Grouped,
8 Point
Genius Discrete
I/O Block,
115 VAC/125 VDC
Isolated, 8 Point
Genius Discrete
I/O Block,
115 VAC/125 VDC
Isolated, 8 Point,
w/o Failed Switch
Diagnostic
Genius Relay
Output Block,
Grouped,
16 Points,
Normally Closed
Genius Relay
Output Block,
Grouped, 1
6 Points,
Normally Open
Mature
Mature
Mature
Mature
Mature
Mature
Network Support
Genius Bus
Genius Bus
Genius Bus
Genius Bus
Genius Bus
Genius Bus
Input Range
93-132 VAC
93-132 VAC
115 VAC / 125 VDC
115 VAC / 125 VDC
N/A
N/A
N/A
93-132 VAC
115 VAC / 125 VDC
115 VAC / 125 VDC
5V to 250 VAC
or 5V to 220 VDC;
Relay Normally–
Closed Relays
5V to 250 VAC
or 5V to 220 VDC;
Relay Normally–
Open Relays
16
8
8
8
16
16
Input 1 msec plus
configurable filter
10 to 100mS in
10mS increments
Input 2msec plus
configurable filter
10 to 100mS in
10mS increments;
Outputs Zero
crossing
Input 2msec plus
configurable filter
10 to 100mS in
10mS increments;
Outputs Zero
crossing
Input 2msec plus
configurable filter
10 to 100mS in
10mS increments;
Outputs Zero
crossing
5.0 msec.
5.0 msec.
11.6K ohms
13K ohms
13K ohms
13K ohms
N/A
N/A
N/A
2 Amp
2.0 Amp
2.0 Amp
2 Amp
2 Amp
Two groups of 8
One group of 8
Four groups of 2
Four groups of 2
Four groups of 4
Four groups of 4
N/A
Internal electronic
short circuit trip.
100ms long time trip
Internal electronic
short circuit trip.
100ms (AC), 10ms
(DC) long time trip
Internal electronic
short circuit trip.
100ms (AC), 10ms
(DC) long time trip
N/A
N/A
Input Diagnostics:
Open Wire, Short
Circuit
Input Diagnostics:
Open Wire,
Overtemperature,
Failed Switch Output
Diagnositcs: Short
Circuit, Overload, No
Load, Failed Switch,
Overtemperature,
Pulse Test
None
None
93-132 VAC
93-132 VAC
93-132 VAC /
105-132 VDC
93-132 VAC /
105-132 VDC
93-132 VAC /
185-265 VAC
93-132 VAC /
185-265 VAC
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
Product Name
Lifecycle Status
Output Range
Number of Points
Input and Output Response
Time - ON/OFF (msec.)
Input Impedance
Load Current Per Point
Points Per Common
Protection
Diagnostics
Operating Voltage
Dimensions (H x W x D)
www.ge-ip.com
Input Diagnostics:
Input Diagnostics:
Open Wire,
Open Wire,
Overtemperature,
Overtemperature,
Loss of I/O Power,
Loss of I/O Power,
Failed Switch Output Failed Switch Output
Diagnostics: Short
Diagnostics: Short
Circuit, Overload, No
Circuit, Overload, No
Load, Overtemp., Loss Load, Overtemp., Loss
of I/O Power, Failed
of I/O Power, Failed
Switch, Pulse Test
Switch, Pulse Test
GE Intelligent Platforms Control Systems Solutions
3.41
Genius I/O
Industrial I/O
DC Discrete I/O Modules
Genius DC Discrete I/O blocks interface to a wide range of input devices, including both 2–wire and 3–
wire electronic proximity switches. Outputs may be low–power control and indicating devices such as
relays, contactors, and lamps. These blocks have identical discrete I/O circuits, each easily configured to
be an input or an output. Output circuits can be directly connected to input circuits without the use of
other components or inversion of logic states. This flexibility provides maximum design and application
efficiency. Each circuit contains built–in protection when used as an output, protecting the driver while
allowing short–time surges. It also protects against shorted loads caused by wiring errors.
IC660BBD020
Product Name
Lifecycle Status
Network Support
Input Range
Sink/Source
Genius Discrete I/O
Block, 24/48 VDC
Grouped, 16 Point,
Source
IC660BBD021
IC660BBD022
IC660BBD023
Genius Discrete I/O
Genius Discrete I/O
Genius Discrete I/O
Block, 24/48 VDC
Block, 24 VDC Grouped, Block, 24 VDC Grouped,
Grouped, 16 Point, Sink
16 Point, Source
16 Point, Sink
IC660BBD024
Genius Discrete I/O
Block, 12/24 VDC
Grouped, 32 Point,
Source
Mature
Mature
Mature
Mature
Mature
Genius Bus
Genius Bus
Genius Bus
Genius Bus
Genius Bus
18-56 VDC (24/48 V)
18-56 VDC (24/48 V)
18-30 VDC (24 V)
18-30 VDC (24 V)
18-30 VDC (24 V)
Source
Sink
Source
Sink
Source
18-56 VDC (24/48 V)
18-56 VDC (24/48 V)
18-30 VDC (24 V)
18-30 VDC (24 V)
18-30 VDC (24 V)
16
16
16
16
32
Input 1.7 msec plus
configurable filter:
5 to 100mS for input;
Output 1.0 msec
Input 1.7 msec plus
configurable filter:
5 to 100mS for input;
Output 1.0 msec
Input 1.7 msec plus
configurable filter:
5 to 100mS for input;
Output 1.0 msec
Input 1.7 msec plus
configurable filter:
5 to 100mS for input;
Output 1.0 msec
Input 1.4 msec plus
configurable filter:
1 to 100mS for input;
Output 0.5 msec
5.6K ohms (24/48V),
1.8K ohms (24V)
5.6K ohms (24/48V),
1.8K ohms (24V)
5.6K ohms (24/48V),
1.8K ohms (24V)
5.6K ohms (24/48V),
1.8K ohms (24V)
3.3 K ohms
2 Amp
2 Amp
2 Amp
2 Amp
0.5 Amp
One group of 16
One group of 16
One group of 16
One group of 16
One group of 32
Output Range
Number of Points
Input and Output Response Time ON/OFF (msec.)
Input Impedance
Load Current Per Point
Points Per Common
Protection
Diagnostics
Operating Voltage
Dimensions (H x W x D)
3.42
Short circuit level sensor Short circuit level sensor Short circuit level sensor Short circuit level sensor Short circuit level sensor
at the switching device at the switching device at the switching device at the switching device at the switching device
Input Diagnostics:
Open wire,
Overtemperature,
Failed Switch Output
Diagnostics: Short
Circuit, Overload,
No Load, Failed Switch,
Overtemperature,
Pulse Test
Input Diagnostics:
Open wire,
Overtemperature,
Failed Switch Output
Diagnostics: Short
Circuit, Overload,
No Load, Failed Switch,
Overtemperature,
Pulse Test
Input Diagnostics:
Open wire,
Overtemperature,
Failed Switch Output
Diagnostics: Short
Circuit, Overload,
No Load, Failed Switch,
Overtemperature,
Pulse Test
Input Diagnostics:
Open wire,
Overtemperature,
Failed Switch Output
Diagnostics: Short
Circuit, Overload,
No Load, Failed Switch,
Overtemperature,
Pulse Test
Output Diagnostics:
Short Circuit,
Overload, Failed Switch,
Pulse Test
18-56 VDC (24/48 V)
18-56 VDC (24/48 V)
18-30 VDC (24 V)
18-30 VDC (24 V)
10-30 VDC
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
Genius I/O
DC Discrete I/O Modules
Genius DC Discrete I/O blocks interface to a wide range of input devices, including both 2–wire and 3–
wire electronic proximity switches. Outputs may be low–power control and indicating devices such as
relays, contactors, and lamps. These blocks have identical discrete I/O circuits, each easily configured to
be an input or an output. Output circuits can be directly connected to input circuits without the use of
other components or inversion of logic states. This flexibility provides maximum design and application
efficiency. Each circuit contains built–in protection when used as an output, protecting the driver while
allowing short–time surges. It also protects against shorted loads caused by wiring errors.
IC660BBD025
IC660BBS102
IC660BBS103
IC660BBR100
IC660BBR101
Product Name
Genius Discrete
I/O Block, 5/12/24 VDC
Grouped, 32 Point, Sink
Genius Discrete
I/O Block, 115 VAC/125
VDC Isolated, 8 Point
Genius Discrete
I/O Block, 115 VAC/125
VDC Isolated, 8 Point,
w/o Failed Switch
Diagnostic
Genius Relay Output
Block, Grouped,
16 Points,
Normally Closed
Genius Relay Output
Block, Grouped,
16 Points,
Normally Open
Lifecycle Status
Mature
Mature
Mature
Mature
Mature
Genius Bus
Genius Bus
Genius Bus
Genius Bus
Genius Bus
Input Range
10-30 VDC (12/24 V),
4.9-5.3 VDC (5 V)
115 VAC / 125 VDC
115 VAC / 125 VDC
N/A
N/A
Sink/Source
Sink
N/A
N/A
N/A
N/A
10-30 VDC (12/24 V),
4.9-5.3 VDC (5 V)
115 VAC / 125 VDC
115 VAC / 125 VDC
5V to 250 VAC or 5V
to 220 VDC; Relay
Normally-Closed Relays
5V to 250 VAC or 5V
to 220 VDC; Relay
Normally-Open Relays
32
8
8
16
16
Input 1.4 msec plus
configurable filter:
1 to 100mS for input;
Output 0.5 msec
Input 2msec plus
configurable filter
10 to 100mS in 10mS
increments; Outputs
Zero crossing
Input 2msec plus
configurable filter
0 to 100mS in 10mS
increments; Outputs
Zero crossing
5.0 msec.
5.0 msec.
3.3 K ohms
13K ohms
13K ohms
N/A
N/A
0.5 Amp
2.0 Amp
2.0 Amp
2 Amp
2 Amp
One group of 32
Four groups of 2
Four groups of 2
Four groups of 4
Four groups of 4
N/A
N/A
None
None
Network Support
Output Range
Number of Points
Input and Output Response Time ON/OFF (msec.)
Input Impedance
Load Current Per Point
Points Per Common
Protection
Short circuit level sensor Internal electronic short Internal electronic short
at the switching device circuit trip. 100ms (AC),
circuit trip. 100ms (AC),
10ms (DC) long time trip 10ms (DC) long time trip
Output Diagnostics:
Short Circuit, Overload,
Failed Switch, Pulse Test
Diagnostics
Operating Voltage
Dimensions (H x W x D)
www.ge-ip.com
Input Diagnostics:
Input Diagnostics:
Open Wire,
Open Wire,
Overtemperature
Overtemperature,
Loss of I/O Power,
Loss of I/O Power,
Failed Switch Output
Failed Switch Output
Diagnostics: Short
Diagnostics: Short
Circuit, Overload, No
Circuit, Overload, No
Load, Overtemp., Loss of Load, Overtemp., Loss of
I/O Power, Failed Switch, I/O Power, Failed Switch,
Pulse Test
Pulse Test
10-30 VDC (12/24 V),
4.9-5.3 VDC (5 V)
93-132 VAC /
105-132 VDC
93-132 VAC /
105-132 VDC
93-132 VAC /
185-265 VAC
93-132 VAC /
185-265 VAC
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
GE Intelligent Platforms Control Systems Solutions
3.43
Genius I/O
Industrial I/O
Analog Input Modules
Genius Analog Input blocks provide 6 channels of current inputs with powerful diagnostics.
IC660BBA026
IC660BBA106
Product Name
Genius Analog Input Block,
Current-source, 6 Channels,
24/48 VDC Powered
Genius Analog Input Block,
Current-source, 6 Channels,
115 VAC/125 VDC Powered
Lifecycle Status
Mature
Mature
Genius Bus
Genius Bus
4 mA to 20 mA
0 mA to 25 mA
4 mA to 20 mA
0 mA to 25 mA
6
6
Channel to Channel Isolation.
6 isolated points
Channel to Channel Isolation.
6 isolated points
1 micro Amp
1 micro Amp
16.6mS to 400mS (user selectable)
16.6mS to 400mS (user selectable)
0.1% of full scale reading
0.1% of full scale reading
Underrange, Overrange, High Alarm,
Low Alarm, Open Wire
Underrange, Overrange, High Alarm,
Low Alarm, Open Wire
18-56 VDC
93-132 VAC / 105-145 VDC
8.83” (22.44cm) x 3.50” (8.89cm) x 3.94” (10.00cm)
8.83” (22.44cm) x 3.50” (8.89cm) x 3.94” (10.00cm)
Network Support
Input Range
Number of Points
Points Per Common
Resolution
Update Rate
Accuracy
Diagnostics
Operating Voltage
Dimensions (W x H x D)
3.44
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
Genius I/O
Analog Output Modules
Genius Analog Output blocks provide 6 channels of current and voltage outputs
with powerful diagnostics.
IC660BBA025
IC660BBA105
Product Name
Genius Analog Output Block,
Current-source, 6 Channels,
24/48 VDC Powered
Genius Analog Output Block,
Current-source, 6 Channels,
115 VAC/125 VDC Powered
Lifecycle Status
Mature
Mature
Genius Bus
Genius Bus
4 mA to 20 mA
0 mA to 24 mA
4 mA to 20 mA
0 mA to 24 mA
6 Outputs
6 Outputs
Points Per Common
One group of 6
One group of 6
Operating Voltage
18-56 VDC
93-132 VAC / 105-145 VDC
6 micro Amp
6 micro Amp
25mS
25mS
0.15% of full–scale reading
0.15% of full–scale reading
8.83” (22.44cm) x 3.50” (8.89cm) x 3.94” (10.00cm)
8.83” (22.44cm) x 3.50” (8.89cm) x 3.94” (10.00cm)
Network Support
Output Range
Number of Points
Resolution
Update Rate
Accuracy
Dimensions (W x H x D)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.45
Genius I/O
Industrial I/O
Analog Mixed Modules
Genius Analog Mixed blocks provide 4 channels of inputs and 2 channels of outputs.
The channels can be configured for current or voltage with powerful diagnostics.
IC660BBA020
IC660BBA100
IC660BBA024
IC660BBA104
Product Name
Genius Analog I/O Block,
Voltage/Current,
4 Inputs/ 2 Outputs,
24/48 VDC Powered
Genius Analog I/O Block,
Voltage/Current,
4 Inputs/ 2 Outputs,
115 VAC Powered
Genius Analog I/O Block,
Current-source,
4 Inputs/ 2 Outputs,
24/48 VDC Powered
Genius Analog I/O Block,
Current-source,
4 Inputs/ 2 Outputs,
115 VAC/ 125 VDC Powered
Lifecycle Status
Mature
Mature
Mature
Mature
Network Support
Genius Bus
Genius Bus
Genius Bus
Genius Bus
Number of Points
4 In / 2 Out
4 In / 2 Out
4 In / 2 Out
4 In / 2 Out
One group of 4 Inputs and
one group of 2 Outputs
One group of 4 Inputs and
one group of 2 Outputs
One group of 4 Inputs and
one group of 2 Outputs
One group of 4 Inputs and
one group of 2 Outputs
Points Per Common
Input Range
0–10 VDC, 10 VDC, 5 VDC,
0–10 VDC, 10 VDC, 5 VDC,
0–5 VDC, 4–20 mA (or 1–5 VDC) 0–5 VDC, 4–20 mA (or 1–5 VDC)
4 mA to 20 mA
4 mA to 20 mA
Output Range
0–10 VDC, 10 VDC, 5 VDC,
0–10 VDC, 10 VDC, 5 VDC,
0–5 VDC, 4–20 mA (or 1–5 VDC) 0–5 VDC, 4–20 mA (or 1–5 VDC)
4 mA to 20 mA
4 mA to 20 mA
Operating Voltage
18-56 VDC
98-132 VAC
18-56 VDC
93-132 VAC / 105-145 VDC
12 bit + sign
12 bit + sign
Input: 1 micro Amp
Output: 6 micro Amp
Output: 6 mA
Once every 4mS
Once every 4mS
Input: 16.6mS to 400mS
(user selectable)
Output: 6mS to 8mS typical
Input: 16.6mS to 400mS
(user selectable)
Output: 6mS to 8mS typical
Accuracy
Typical: 0.2% of full scale;
Maximum: 0.5% of full scale:
within 50mV on the 10 volt
range, 25mV on the 5 volt
range, and 100mA on the 4
to 20 mA range.
Typical: 0.2% of full scale;
Maximum: 0.5% of full scale:
within 50mV on the 10 volt
range, 25mV on the 5 volt
range, and 100mA on the 4
to 20 mA range.
Input: 0.1% of full scale
reading
Output: 0.15% of full
scale reading
Input: 0.1% of full scale
reading
Output: 0.15% of full
scale reading
Input Filter Response
none, 8, 16, 32, 64, 128, 256,
512, 1024mS
none, 8, 16, 32, 64, 128, 256,
512, 1024mS
16.6mS to 400mS
(user selectable)
16.6mS to 400mS
(user selectable)
Resolution
Update Rate
Diagnostics
Dimensions (W x H x D)
3.46
Input: Underrange, Overrange, Input: Underrange, Overrange, Input: Underrange, Overrange, Input: Underrange, Overrange,
High Alarm, Low Alarm,
High Alarm, Low Alarm,
High Alarm, Low Alarm,
High Alarm, Low Alarm,
Open Wire Output:
Open Wire Output:
Open Wire Output:
Open Wire, Output:
Underrange, Overrange
Underrange, Overrange
Underrange, Overrange,
Underrange, Overrange,
Feedback error
Feedback error
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
GE Intelligent Platforms Control Systems Solutions
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
www.ge-ip.com
Industrial I/O
Genius I/O
RTD and Thermocouple Modules
Genius Temperature Sensor blocks support a wide range of temperature sensors.
The blocks support powerful diagnostics.
IC660BBA021
IC660BBA101
IC660BBA023
IC660BBA103
Product Name
Genius Analog Input Block,
RTD, 6 Channel,
24/48 VDC Powered
Genius Analog Input Block,
RTD, 6 Channel,
115 VAC/125 VDC Powered
Genius Analog Input Block,
Thermocouple, 6 Channel,
24/48 VDC Powered
Genius Analog Input Block,
Thermocouple, 6 Channel,
115 VAC/125 VDC Powered
Lifecycle Status
Mature
Mature
Mature
Mature
Network Support
Genius Bus
Genius Bus
Genius Bus
Genius Bus
Number of Points
6
6
6
6
3 groups of 2
3 groups of 2
3 groups of 2
3 groups of 2
2 and 3 wire
Platinum (DIN 43760),
Nickel (DIN 43760),
Copper, Linear
2 and 3 wire
Platinum (DIN 43760),
Nickel (DIN 43760),
Copper, Linear
J, K, T, E, B, R, S, and N
(#14 AWG Nicrosil vs. Nisil)
thermocouples
J, K, T, E, B, R, S, and N
(#14 AWG Nicrosil vs. Nisil)
thermocouples
18-56 VDC
93-132 VAC / 105-145 VDC
18-56 VDC
93-132 VAC / 105-145 VDC
0.1°C
0.1°C
Less than 0mV error typ,
20mV max.
Less than 0mV error typ,
20mV max.
Once every 400 ms,
800 ms, or 1600 ms
Once every 400 ms,
800 ms, or 1600 ms
2.0 sec (typ), 3.0 sec (max)
2.0 sec (typ), 3.0 sec (max)
At 25°C - Platinum or Nickel:
0.5°C typical, 1.0°C maximum
10W Copper: 5°C typical,
10°C maximum
8 Hz at 25°C
8 Hz at 25°C
Accuracy
At 25°C - Platinum or Nickel:
0.5°C typical, 1.0°C maximum
10W Copper: 5°C typical,
10°C maximum
Diagnostics
Input shorted, Internal fault,
Wiring error, Open wire,
Overrange, Underrange,
High Alarm, Low Alarm
Input shorted, Internal fault,
Wiring error, Open wire,
Overrange, Underrange,
High Alarm, Low Alarm
Open Wire, Overrange,
Underrange, High Alarm,
Low Alarm, Internal Fault
Open Wire, Overrange,
Underrange, High Alarm,
Low Alarm, Internal Fault
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
8.83” (22.44cm) x
3.50” (8.89cm) x
3.94” (10.00cm)
Points Per Common
Input Range
Operating Voltage
Resolution
Update Rate
Dimensions (W x H x D)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.47
Genius I/O
Industrial I/O
High Speed Counter
The Genius I/O High-speed Counter block is a self-contained, configurable I/O module
which provides direct processing of rapid pulse signals up to 200kHz.
IC660BBD120
Product Name
Genius High Speed Counter Block
Lifecycle Status
Mature
Network Support
Genius Bus
Input Range
5 VDC to 30 VDC
Count Rate
high-frequency filter selected 200 kHz maximum
low-frequency filter selected 40 Hz maximum
Output Range
Number of Points
Input and Output Response Time ON/OFF (msec.)
Input Filter Response
4.75 VDC to 5.25 VDC
4 Type A or 2 Type B or 1 Type C (12 inputs and 4 outputs)
high-frequency filter selected 2.5mS minimum
low-frequency filter selected 12.5mS minimum
High (2.5mS) or low (12.5mS) frequency
Input Impedance
Accuracy
4.0K ohms
0.50% reading + 0.50% full scale
Load Current Per Point
200 mA
Operating Voltage
Diagnostics
Dimensions (W x H x D)
3.48
93-132 VAC / 10-30 VDC
Outputs: Pulse Test, Failed Switch
8.83” (22.44cm) x 3.50” (8.89cm) x 3.94” (10.00cm)
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
Genius I/O
PowerTRAC Monitoring Module
The Genius PowerTRAC block is used in many types of power monitoring and industrial applications. The PowerTRAC block
monitors current and voltage inputs and stores digitized waveform values for each input. From these values, the block
calculates RMS voltage, current, active power, reactive power, KWH, and power factor. The block automatically sends this
calculated data to a host PLC or computer approximately twice per second. The same data can be displayed on a Genius
Hand–held Monitor, either locally or from any connection point on the bus.
A PowerTRAC block can be used with a wye– or delta–configured three–phase power system or with a single–phase power
system. It accepts voltage inputs from one to three potential transformers, and current inputs from up to three line current
transformers, plus a neutral current transformer.
IC660BPM100
Product Name
Genius I/O PowerTrac Monitoring Block, Accurately measures RMS voltage,
current, power, VARs, power factor, watt–hours, and line frequency,
even with distorted waveforms.115 VAC/125 VDC Powered
Lifecycle Status
Mature
Network Support
Input Range
Genius Bus
0 to 120 VAC RMS at 47 to 63 Hz
Number of Points
(1) Three Phase
Calculated Data
Voltage phase A to B
Voltage phase B to C
Voltage phase C to A
Voltage phase A to N (for line–to–neutral potential transformers only)
Voltage phase B to N (for line–to–neutral potential transformers only)
Voltage phase C to N (for line–to–neutral potential transformers only)
Current phase A
Current phase B
Current phase C
Auxiliary CT current
Active power phase A
Active power phase B
Active power phase C
Reactive power phase A
Reactive power phase B
Reactive power phase C
Total power factor Total watt–hours/KWH/MWH
Fundamental VARS phase A
Fundamental VARS phase B
Fundamental VARs phase C
Fundamental Power Factor
Harmonic VARS as % of Volt–Amps phase A
Harmonic VARs as % of Volt–Amps phase B
Harmonic VARs as % of Volt–Amps phase C
Total Harmonic VARs as % of Volt–Amps
Line Frequency
Temperature Alarm
Extended Watt-hours (high)
Extended Watt-hours (low)
Accuracy
Operating Voltage
Dimensions (W x H x D)
www.ge-ip.com
0.25% reading +0.25% full scale
115 VAC/230 VAC (90–265 VAC), 47–63Hz
or 125 VDC (100–150 VDC), 35 VA max.
11.00” (27.94cm) x 5.21” (13.23cm) x 8.06” (20.47)
GE Intelligent Platforms Control Systems Solutions
3.49
Genius I/O
Industrial I/O
Accessories and Cables
IC660BSM021
Genius Bus Switching Module, 24/48 VDC
Mature
IC660BSM120
Genius Bus Switching Module, 115 VAC/125 VDC
Mature
IC660BLC001
Genius bus Cable w/Connectors Alpha 9823 15 In (Qty 3)
Active
IC660BLC003
Genius bus Cable w/Connectors Alpha 9823 3 Ft
Active
IC660BLM506
Bus Terminator 150 Ohm (Qty 4)
Active
IC660BLM508
Bus Terminator 75 Ohm (Qty 4)
Active
IC660BLM507
Genius Block Puller
Active
Hand Held Monitor
IC660HHM501
Hand-Held Monitor can be used to configure and trouble shoot Genius blocks. Kit
includes Cable and Battery Charger
Mature
IC660BCM501
Hand-Held Monitor Battery Charger
Active
IC660BPM500
Hand-Held Monitor Battery Pack
Mature
3.50
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
Genius I/O
Configuration Guidelines
When configuring a Genius network the following guidelines should be considered
1.
Genius LAN is limited to 32 devices. Remember that the Genius Bus Controller reserves one address and if a Hand-Held configurator
is used, it also reserves an address.
2.
If the application requires redundant networks, a Bus Switching Module is required (IC660BSMxxx).
3.
Termination is required at the end of each network (IC660BLM50x)
4.
For long distances, beyond 4,500 feet, the number of devices is limited to 16.
Cable Selection
Cable #
& Make
Outer
Diameter
Terminating Resistor*
-10% to +20%
1/2 Watt
Number of
Conductors/
AWG
Dielectric
Voltage
Rating
Ambient
Temp
Rating
Maximum Length Cable Run,
feet/meters at baudrate
153.6s
153.6e
76.8
38.4*
(A)9823
(B)9182
(C)4596
(M)M39240
.350 in
8.89mm
150 ohms
2/#22
30V
60°C
2000ft
606m
3500ft
1061m
4500ft
1364m
7500ft
2283m
(B)89182
.322in
8.18mm
150 ohms
2/#22
150V
200°C
2000ft
606m
3500ft
1061m
4500ft
1364m
7500ft
2283m
(B)9841
(M)M3993
.270in
6.86mm
*120 ohms
2/#24
30V
80°C
1000ft
303m
1500ft
455m
2500ft
758m
3500ft
1061m
(A)9818C
(B)9207
(M)M4270
.330in
8.38mm
100 ohms
2/#20
300V
80°C
1500ft
455m
2500ft
758m
3500ft
1061m
6000ft
1818m
(A)9109
(B)89207
(C)4798
(M)M44270
.282in
7.16mm
100 ohms
2/#20
150V
200°C
1500ft
455m
2500ft
758m
3500ft
1061m
6000ft
1818m
(A)9818D
(B)9815
.330in
8.38mm
100 ohms
2/#20
1500ft
455m
2500ft
758m
3500ft
1061m
6000ft
1818m
(A)9818
(B)9855
(M)M4230
.315in
8.00mm
100 ohms
4 (two pair)
#22
150V
60°C
1200ft
364m
1700ft
516m
3000ft
909m
4500ft
1364m
(A)9110
(B)89696
(B)89855
(M)M64230
.274in
6.96mm
100 ohms
4 (two pair)
#22
150V
200°C
1200ft
364m
1700ft
516m
3000ft
909m
4500ft
1364m
(A)9814C
(B)9463
(M)M4154
0.243
6.17mm
75 ohms
2/#20
150V
60°C
800ft
242m
1500ft
455m
2500ft
758m
3500ft
1061m
(A)5902C
(B)9302
(M)M17002
.244in
6.20mm
75 ohms
4 (two pair)
#22
300V
80°C
200ft
60m
500ft
152m
1200ft
333m
2500ft
758m
Notes:
A=Alpha, B=Belden, C=Consolidated, M=Manhattan, * = Limited to 16 taps at 38.4 Kbaud
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.51
Genius I/O
Industrial I/O
Examples of Typical Application
Configuration for Controller (Example application requiring (120) 24 VDC inputs and (80) Relay outputs AC power supply) for local control. System also has five remote
cabinets, with each cabinet requiring (64) 24 VDC Inputs, (21) 24 VDC 0.5 Amp, Source Outputs and (2) current inputs and (2) current outputs (24 VDC power source). Maximum
­distance from control cabinet to the last remote cabinet is 3,500 feet.
Control Cabinet
Backplane Slots Required
2
Power Supply
Current Required (mA)
1250mA @ 3.3 VDC; 1000mA @ 5 VDC
Qty
Part Number
Description
1
IC695CPU310
CPU with two built-in serial ports
1
IC695PSA040
120/240 VAC, 125 VDC Power Supply, current available 9 Amps @
3.3 VDC; 6 Amps @ 5 VDC; 1.6 Amps @ 24 VDC maximum
600mA @ 3.3 VDC; 240 mA @ 5 VDC
1
IC695CHS016
16 Slot Universal Base
4
1200mA @ 5V
4
IC694MDL660
Discrete Input Module, 24 VDC Positive Logic, 32 points
(Requires terminal block)
5
35mA @ 5V; 110mA @ 24 VDC Relay
5
IC694MDL940
Discrete Output Module, Relay 2.0 A per point Form A, 16 points
(Terminal block included).
4
IC694TBB032
Terminal Block, Box Style
1
IC694BEM331
Genius Bus Controller (GBC), supports up to 32 devices on a
Genius Bus to control remote I/O, Global Data and Datagrams
1
BC646MPP001
Logic Developer - PLC Professional
2
1
300 mA @ 5 VDC
14
Total current from power supply required: 2775mA @ 5V; 1850 @ 3.3V; 110mA @ 24 VDC Relay. Only one power supplied needed.
Remote Cabinets (Qty 5)
15
IC660BBD024
Block 12/24 VDC Source I/O 32 Circuits
5
IC660BBA020
Block 24/48 VDC Analog 4 Inputs / 2 Outputs
1
IC660BLM506
Bus Terminator 150 Ohm (Qty 4)
1
IC660HHM501
Hand-Held Monitor can be used to configure and troubleshoot
Genius blocks. Kit includes Cable and Battery Charger
5
IC660BLM507
Genius Block Puller
1
IC695ETM001
RX3i Ethernet module 10/100 Mbits 2 RJ45 connections one IP
address occupies one slot on system base
6
IC690PWR024
24 VDC, 5 Amp Output Power and 120/230 VAC
Input Power Power Supply
1
IC693ACC302
RX3i Long term battery for CPU
1
IC754VSI06STD
QuickPanel View Intermediate 6 inch STN Touch Operator Interface
Options to consider
840mA @ 3.3 VDC; 614 mA @ 5 VDC
3.52
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaPoint and VersaSafe I/O
VersaPoint and VersaSafe I/O
The VersaPoint Distributed I/O system
provides compact flexibility and allows
users to install just the right amount of
I/O needed for each application.
Adhering to open communications
standards including Ethernet, ProfibusDP and DeviceNet™, VersaPoint connects
easily to a wide variety of PLCs, DCSs
and PC-based control systems. It is ideal
for packaging and materials handling
applications as well as for supervisory
control and data acquisition.
densities from 1 to 16 points. It also
supports a host of specialized modules,
from RTD and Thermocouple inputs to
positioning and counter modules.
Its compact design results in space
savings up to 50 percent compared to
conventional systems. The modules
snap quickly and securely onto a DINrail, and the integrated I/O terminals
and internal power bus help reduce
wiring by as much as 80 percent.
Proficy Machine Edition
Proficy Machine Edition is an
advanced software environment for
the development and maintenance
of machine level automation.
Visualization, motion control, and
­execution logic are developed with
a single programmer.
VersaPoint accommodates a series of
discrete and analog I/O modules with
Network Interface Module
page 3.54
Power Terminals
page 3.55
Segment Terminals
page 3.56
Discrete Input Modules
page 3.57
Discrete Output Modules
pages 3.58-3.59
Analog Input Modules
page 3.60
Analog Output Modules
page 3.61
Functional Safety Modules
page 3.62
Motion Modules
page 3.63
Motor Starter Modules
page 3.64
Serial Communications Modules
page 3.65
Accessories and Cables
page 3.66
Configuration Guidelines
page 3.67
Publication Reference Chart
GFK-2134
VersaPoint Motor Starters Manual
GFK-2125
VersaPoint Positioning Modules Manual
GFK-1911
VersaPoint I/O System Profibus-DP NIU
GFK-1912
VersaPoint I/O System DeviceNet NIU
User’s Manual
GFK-2087
VersaPoint Ethernet NIU
(IC220EBI001 and IC220EBI002)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.53
VersaPoint and VersaSafe I/O
Industrial I/O
Network Interface Modules
An I/O Network Interface Unit connects VersaPoint I/O modules to a host PLC or computer
via a variety of networks, which makes it easy to include VersaPoint I/O in Profibus-DP,
Ethernet or DeviceNet installations. Together, the NIU is capable of handling up to 63
­modules in one node.
Product Name
Lifecycle Status
Protocol
IC220EBI001
IC220EBI002
IC220PBI002
IC220DBI001
Ethernet TCP/IP Advanced
Network Interface Unit
- 10/100 Base-T(X)
- PCP Support
Ethernet TCP/IP Standard
Network Interface Unit
- 10/100 Base-T(X)
Profibus-DP Network
Interface Unit
DeviceNet Network
Interface Unit
Active
Active
Active
Active
Modbus TCP
Modbus TCP
Profibus DP (V1)
DeviceNet Slave
10/100 Base-T(X)
10/100 Base-T(X)
Up to 12Mbits per second
Up to 500 Kbaud
Serial Communications Support
Yes
No
Yes
Yes
Firmware Upgrade
Yes
No
No
No
24 VDC
24 VDC
24 VDC
24 VDC
19.2 - 30 VDC
19.2 - 30 VDC
19.2 - 30 VDC
19.2 - 30 VDC
Data Rate
Nominal Power Input Voltage
Power Voltage Range
Current for Local Bus UL
2 Amp
2 Amp
2 Amp
2 Amp
Current for Local Bus UA (ma)
500 mA
500 mA
500 mA
500 mA
Maximum Supported Modules
63
63
63
63
Power In
8 Amp maximum
8 Amp maximum
8 Amp maximum
8 Amp maximum
Bus diagnostics and status
indication of voltage
Bus diagnostics and status
indication of voltage
Bus diagnostics and status
indication of voltage
Bus diagnostics and status
indication of voltage
Yes
None
None
None
Web Pages
SNMP
XML Data Monitoring
Web Pages
SNMP
XML Data Monitoring
None
None
Required Terminal Strip
(1) IC220TBK082
(Contains 10 strips)
(1) IC220TBK082
(Contains 10 strips)
(1) IC220TBK087
(Contains 10 strips)
(1) IC220TBK201
(Contains 10 strips)
Dimensions (W x H x D)
90mm x 72mm x 116mm
(3.543in. x 2.835in. x 4.567in.)
90mm x 72mm x 116mm
(3.543in. x 2.835in. x 4.567in.)
91mm x 120mm x 71.5mm
(2.874in. x 4.724in. x 2.795in.)
48.8mm x 120mm x 71.5mm
(1.92 x 4.72 x 2.82in.)
LED Indicators
Numeric LCD Display
Web Support
3.54
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaPoint and VersaSafe I/O
Power Terminals
Power Terminal modules supply power to the main circuit (UM). In addition, this module
can be used to supply power for a segment circuit (Us).
Product Name
IC220PWR001
IC220PWR002
IC220PWR003
IC220PWR101
IC220PWR201
Power Terminal
24 VDC
Power Terminal
Fused
24 VDC
Power Terminal
Fused with Diagnostics
24 VDC
Power Terminal
120 VAC
Power Terminal
230 VAC
Lifecycle Status
Active
Active
Active
Active
Input Voltage
24 VDC
24 VDC
24 VDC
120 VAC
230 VAC
19.2 - 30 VDC
19.2 - 30 VDC
19.2 - 30 VDC
108 -135 VAC
12 -253 VAC
8 Amps
8 Amps
6.3 Amps
8 Amps
8 Amps
No
Fuse
Fuse
No
No
Yes, suppressor diode
for voltage limitation
Yes, suppressor diode
for voltage limitation
Yes, suppressor diode
for voltage limitation
Yes, VAR 275 VAC
Yes, VAR 275 VAC
Yes, diode connected in
parallel as protection
against polarity reversal
Yes, diode connected in
parallel as protection
against polarity reversal
Yes, diode connected in
parallel as protection
against polarity reversal
N/A
N/A
N/A
N/A
25 mA, maximum
N/A
N/A
24 VDC Voltage
Present
24 VDC Voltage
Present and Blown Fuse
Bus Diagnostics and
Blown Fuse
120 VAC supply
Present
230 VAC supply
Present
(1) IC220TBK087
(Contains 10 strips)
(1) IC220TBK087
(Contains 10 strips)
(1) IC220TBK087
(Contains 10 strips)
(1) IC220TBK204
(1) IC220TBK204
Input Voltage Range
Maximum Current
Overload/Short Circuit in
Segment Circuit
Surge Voltage/Over Voltage
Polarity Reversal
Current Consumption from
Local Bus UL (mA)
LED Indicators
Required Terminal Strip
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.55
VersaPoint and VersaSafe I/O
Industrial I/O
Segment Terminals
Segment Terminals are used to create a partial circuit (segment circuit) within a main
24 VDC circuit.
Product Name
IC220PWR011
IC220PWR012
IC220PWR013
IC220PWR014
Segment Terminal
24 VDC
Segment Terminal
Fused
24 VDC
Segment Terminal
Fused with Diagnostics
24 VDC
Segment Terminal
Electronic Fused
24 VDC
Lifecycle Status
Active
Active
Active
Active
Input Voltage
24 VDC
24 VDC
24 VDC
24 VDC
19.2 - 30 VDC
19.2 - 30 VDC
19.2 - 30 VDC
19.2 - 30 VDC
8 Amps
8 Amps
6.3 Amps
8 Amps
No
6.3 Amp slow blow fuse
6.3 Amp slow blow fuse
Electronic Fuse
Surge Voltage/Over Voltage
Protective circuits of
the power terminal
Protective circuits of
the power terminal
Protective circuits of
the power terminal
Protective circuits of
the power terminal
Polarity Reversal
Protective circuits of
the power terminal
Protective circuits of
the power terminal
Protective circuits of
the power terminal
Protective circuits of
the power terminal
N/A
N/A
25 mA, maximum
30 mA, maximum
24 VDC Voltage
Present
24 VDC Voltage
Present and Blown Fuse
Bus Diagnostics and
Blown Fuse
Bus Diagnostics and
Blown Fuse
(1) IC220TBK087
(Contains 10 strips)
(1) IC220TBK087
(Contains 10 strips)
(1) IC220TBK087
(Contains 10 strips)
(1) IC220TBK087
(Contains 10 strips)
Input Voltage Range
Maximum Current
Overload/Short Circuit in
Main Circuit
Current Consumption from
Local Bus UL (mA)
LED Indicators
Required Terminal Strip
3.56
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaPoint and VersaSafe I/O
Discrete Input Modules
Discrete input modules receive signals from input devices such as sensors, pushbuttons,
and switches that can have two states: on or off, open or closed.
Product Name
Lifecycle Status
Input Voltage
IC220MDL641
IC220MDL642
IC220MDL643
IC220MDL644
IC220MDL661
Input 24 VDC Positive
Logic 2 Points
Input 24 VDC Positive
Logic 4 Points
Input 24 VDC Positive
Logic 8 Points
Input 24 VDC Positive
Logic 16 Points
Input 24 VDC Negative
Logic 2 Points
Active
Active
Active
Active
Active
0 - 30 VDC
0 - 30 VDC
0 - 30 VDC
0 - 30 VDC
0 - 30 VDC
Number of Points
2
4
8
16
2
Connection Style
2, 3, and 4 wire
2 and 3 wire
2, 3, and 4 wire
2 and 3 wire
2, 3, and 4 wire
Input Response Time
Less than 1 msec.
Less than 1 msec.
Less than 1 msec.
Less than 1 msec.
Less than 1 msec.
On State Current
5 mA
4 mA
5 mA
4 mA
5 mA
Off State Current
0.4 mA
0.4 mA
0.4 mA
0.4 mA
0.4 mA
Current Consumption for
Local Bus UL (mA)
35 mA
40 mA
50 mA
60 mA
35 mA, maximum
0.5 Amp max
1.0 Amp max
2.0 Amp max
4.0 Amp max
0.5 A (2 x 0.25 A), maximum
Bus Diagnostics Status
indication of inputs
Bus Diagnostics Status
indication of inputs
Bus Diagnostics Status
indication of inputs
Bus Diagnostics Status
indication of inputs
Bus Diagnostics Status
indication of inputs
(1) IC220TBK082
(Contains 10 strips)
(1) IC220TBK122
(Contains 10 strips)
(4) IC220TBK082
(Contains 10 strips)
(4) IC220TBK122
(Contains 10 strips)
(1) IC220TBK082
(Contains 10 strips)
Nominal Current
Consumption of US
LED Indicators
Required Terminal Strip
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.57
VersaPoint and VersaSafe I/O
Industrial I/O
Discrete Output Modules
Discrete output modules send control signals to devices such as contactors, indicator
lamps, and interposing relays that can also have two states.
IC220MDL751
IC220MDL721
IC220MDL752
IC220MDL753
Product Name
Output 24 VDC Positive
Logic 0.5 A 2 Points
Output 24 VDC Positive
Logic 2.0 A 2 Points
Output 24 VDC Positive
Logic 0.5 A 4 Points
Output 24 VDC Positive
Logic 0.5 A 8 Points
Lifecycle Status
Active
Active
Active
Active
Output Voltage
24 VDC
24 VDC
24 VDC
24 VDC
Number of Points
2
2
4
8
Connection Style
2, 3, and 4 wire
2, 3, and 4 wire
2 and 3 wire
2, 3, and 4 wire
Load Current per Point
0.5 A
2.0 A
0.5 A
0.5 A
Electronic Short Circuit,
Overload Protection
Electronic Short Circuit,
Overload Protection
Electronic Short Circuit,
Overload Protection
Electronic Short Circuit,
Overload Protection
Current Consumption from
Local Bus UL (mA)
33 mA max.
35 mA max.
44 mA max.
60 mA max.
Nominal Current
Consumption of US
1 Amp max
4 Amp max
2 Amp max
4 Amp max
Bus Diagnostics Status
indication of outputs
Bus Diagnostics Status
indication of outputs
Bus Diagnostics Status
indication of outputs
Bus Diagnostics Status
indication of outputs
(1) IC220TBK082
(Contains 10 strips)
(1) IC220TBK082
(Contains 10 strips)
(1) IC220TBK123
(Contains 10 strips)
(4) IC220TBK082
(Contains 10 strips)
Protection
LED Indicators
Required Terminal Strip
3.58
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaPoint and VersaSafe I/O
Discrete Output Modules
Discrete output modules send control signals to devices such as contactors, indicator
lamps, and interposing relays that can also have two states.
IC220MDL754
IC220MDL761
IC220MDL930
IC220MDL940
Product Name
Output 24 VDC Positive
Logic 0.5 A 16 Points
Output 24 VDC Negative
Logic 0.5 A 2 Points
Output Relay 3.0 A 1 Point
Output Relay 3.0 A 1 Point
Lifecycle Status
Active
Active
Active
Active
Output Voltage
24 VDC
24 VDC
5 - 253 VAC
5 - 253 VAC
Number of Points
16
2
1
4
Connection Style
2 and 3 wire
2, 3, and 4 wire
2 and 3 wire
2 and 3 wire
Load Current per Point
0.5 A
0.5 A
3.0 A
3.0 A
Electronic Short Circuit,
Overload Protection
Electronic Short Circuit,
Overload Protection
N/A
N/A
Current Consumption from
Local Bus UL (mA)
90 mA max.
32 mA max.
60 mA max.
187 mA max.
Nominal Current
Consumption of US
8 Amp max
1 Amp (2 x 0.5 A), maximum
N/A
N/A
Protection
LED Indicators
Bus Diagnostics Status indication Bus Diagnostics Status indication Bus Diagnostics Status indication Bus Diagnostics Status indication
of outputs
of outputs
of outputs
of outputs
(4) IC220TBK123
(Contains 10 strips)
Required Terminal Strip
www.ge-ip.com
(1) IC220TBK082
(Contains 10 strips)
(1) IC220TBK085
(Contains 10 strips)
Requires Relay Isolation Set
(IC220ACC201 and IC220TBK206)
if switching voltages are not
available in the segment.
(1) IC220TBK085
(Contains 10 strips)
Requires Relay Isolation Set
(IC220ACC201 and IC220TBK206)
if switching voltages are not
available in the segment.
GE Intelligent Platforms Control Systems Solutions
3.59
VersaPoint and VersaSafe I/O
Industrial I/O
Analog Input Modules
Analog input modules receive signals from current and voltage input devices. Specialty
modules are available for RTD and Thermocouple inputs.
IC220ALG220
IC220ALG221
IC220ALG620
IC220ALG630
Product Name
Analog In 15 Bit Voltage/
Current 2 Channels
Analog In 15 Bit Voltage/
Current 8 Channel
Analog In 16 Bit RTD
2 Channels
Analog In 16 Bit Thermocouple
2 Channels
Lifecycle Status
Active
Active
Active
Active
0 - 20 mA, 4 - 20 mA,
±20 mA, 0 - 10 V, ±10 V
0 - 20 mA, 4 - 20 mA,
±20 mA, 0 - 10 V, ±10 V
RTD PT, Ni, Cu, KTY
Thermocouple B, C, E, J, K,
L, N, R, S, T, U, W, HK
Input Voltage
Number of Points
2
8
2
2
Connection Style
2 wire,
shielded sensor cable
2 wire,
shielded sensor cable
2, 3, and 4 wire,
shielded sensor cable
2 wire,
shielded sensor cable
120 micro seconds
10 micro seconds
120 micro seconds
120 micro seconds
Less than 1.5 msec
Less than 0.8 to 1.3 msec
20 to 30 msec (depending on
connection method)
30 msec
Greater than 220 Kohm (voltage)
and 50 ohm (current)
Greater than 240 Kohm (voltage)
and 25 ohm (current)
N/A
N/A
Limit Frequency of the
Input Filter
40 Hz
3.5 Hz
N/A
48 Hz
Current Consumption
for Local Bus UL (mA)
45 mA, typical
48 mA, typical
43 mA, typical
43 mA, typical
N/A
N/A
N/A
N/A
Bus Diagnostics
Bus Diagnostics
Bus Diagnostics
Bus Diagnostics
(1) IC220TBK062
(Contains 5 strips)
(4) IC220TBK062
(Contains 5 strips)
(1) IC220TBK062
(Contains 5 strips)
(1) IC220TBK062
(Contains 5 strips)
Converter
Module Update Rate
Input Resistance
Nominal Current
Consumption of US
LED Indicators
Required Terminal Strip
3.60
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaPoint and VersaSafe I/O
Analog Output Modules
Analog output modules provide voltage or current signals to analog output devices.
IC220ALG320
IC220ALG321
IC220ALG322
Product Name
Analog Out 16 Bit Voltage/
Current 1 Channel
Analog Out 16 Bit Voltage
1 Channel
Analog Out 13 Bit Voltage
2 Channels
Lifecycle Status
Active
Active
Active
Output Voltage
0 - 20 mA, 4 - 20 mA, 0 - 10 V
0 - 10 V
0 - 10 V, ±10 V
Number of Points
8
1
2
Connection Style
2 wire, shielded sensor cable
2 wire, shielded sensor cable
2 wire, shielded sensor cable single ended
Module Update Rate
Less than 1 msec
Less than 1 msec
Less than 1 msec
Voltage: 2 k ohm minimum
Current: 500 k ohm maximum
2 k ohm minimum
2 k ohm minimum
Current Consumption for
Local Bus UL (mA)
30 mA typical,
40 mA maximum
30 mA typical,
40 mA maximum
33 mA typical,
40 mA maximum
Current Consumption from
Analog Bus UANA (mA)
50 mA typical,
65 mA maximum
15 mA typical,
20 mA maximum
25 mA typical,
35 mA maximum
N/A
N/A
N/A
Bus Diagnostics, I/O Voltage
for analog terminals present
Bus Diagnostics
Bus Diagnostics Default state set
(1) IC220TBK203
(Contains 1 strip)
(1) IC220TBK061
(Contains 5 strips)
(1) IC220TBK062
(Contains 5 strips)
Output Load
Nominal Current
Consumption of US
LED Indicators
Required Terminal Strip
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.61
VersaPoint and VersaSafe I/O
Industrial I/O
Functional Safety Modules
VersaSafe is a SIL3 TUV certified safety solution, well integrated in the PACSystems
RX3i platform.
VersaSafe technology offers RX3i users, in particular machine OEMs, a scalable and
cost efficient SIL 3 safety solution, without need of an additional, complex safety PLC
and safety network. Users can add the exact number of safe I/O modules required,
with the ability to expand to more than 100 safe I/Os. Even if the application requires
a low number of safe I/O, VersaSafe still offers a cost efficient solution.
The safety I/O is distributed via VersaPoint Profibus NIU or Profinet RT NIU, and can
be combined with any standard I/O on the same network.
Well integrated into the RX3i system, VersaSafe is easy to use. Since the RX3i is the single point of
connection, both safe and standard I/O can be combined in the same logic program. Integration into
the RX3i also enables significant cost reduction because the status of all safe I/Os is directly available
in the standard application logic without the need to hard wire. The safety programming tool provides
a safe function block library so standard machine safety applications can be realized with configuration instead of complex programming.
IC220SDL543
IC220SDL953
IC220SDL753
IC220SDL752
IC220SDL840
Product Name
Safe Input,
24 VDC
Positive Logic
Safety Logic Modul,
Safe Output, 24 VDC
Postive Logic
Safe Output,
24 VDC
Postive Logic 2 A
Safe Output,
24 VDC Sink/
Source
Safe Output,
Relay 4A, 4PT,
with 2 contacts each
Lifecycle Status
Active
Active
Active
Active
Active
Voltage
0 - 30 VDC
0 - 30 VDC
0 - 30 VDC
0 - 30 VDC
24V and 230V
Applications
Safe Input
Safe Logic Output
Safe Output
Safe Output
Safe Relay Output
Number of Points
SIL2 / CAT3
8
8
8
4
4
Number of Points
SIL3 / CAT4
4
4
4
2
2
Clock Outputs
8
-
-
-
2
Diagnostic Inputs
-
-
-
-
2
Alarm Outputs
-
8
-
-
-
Max. Safety Level
SIL / IEC61508
3
3
3
3
3
Max. Safety Level
SILC / IEC62061
3
3
3
3
3
Max. Safety Level
PL / ISO 13849-1
e
e
e
e
e
Max. Safety Level
Category / CAT
4
4
4
4
4
3.62
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaPoint and VersaSafe I/O
Motion Modules
Motion modules enable the user to easily connect to high speed input devices.
IC220MDD840
IC220MDD841
IC220MDD842
Product Name
High Speed Counter Input,
1 control input,
1 control output
Absolute Encoder Input,
4 digital inputs and
4 digital outputs
Incremental Encoder Input,
4 digital inputs and
4 digital outputs
Lifecycle Status
Active
Active
Active
Number of Points
1
One SSI Encoder
One A QUAD B
Input Frequency
100Khz
400Khz
Up to 500Khz
N/A
26 bit
26 bit
1
4
4
24 VDC / 5 VDC
24 VDC
24 VDC
Maximum Resolution
Number of Inputs
Input Voltage
Number of Outputs
Output Voltage
Connection Style
Protection
Current Consumption
for Local Bus UL (mA)
Nominal Current
Consumption of US
LED Indicators
Required Terminal Strip
www.ge-ip.com
1
4
4
24 VDC, 500 mA
24 VDC, 500 mA
24 VDC, 500 mA
Input: 2 and 3 wire
Output: 2 wire
Input: 2 and 3 wire
Output: 2 and 3 wire
Input: 2 and 3 wire
Output: 2 and 3 wire
Short Circuit Protection
Short Circuit Protection
Short Circuit Protection
40 mA typical, 50 mA maximum
60 mA
110 mA
1.0 Amp maximum
2.0 Amp maximum
2.0 Amp maximum
Bus Diagnostics, Sensor supply
short circuit, Counter input status,
Control input status,
Output status
Bus Diagnostics, Sensor supply
short circuit, Counter input status,
Control input status,
Output status
Bus Diagnostics, Sensor supply
short circuit, Counter input status,
Control input status,
Output status
(1) IC220TBK203
(Contains 1 strip)
(1) IC220TBK202
(Contains 1 strip)
(1) IC220TBK202
(Contains 1 strip)
GE Intelligent Platforms Control Systems Solutions
3.63
VersaPoint and VersaSafe I/O
Industrial I/O
Motor Starter Modules
VersaPoint motor starter modules enable the user to easily connect directly to three phase
motors. The starter control (ON/OFF) and diagnostics is via the VersaPoint bus and no
additional I/O modules required. The motor starter modules reduce wiring and installation.
IC220STR001
IC220STR002
IC220STR003
Product Name
Motor Starter Direct,
up to 1.5 kW / 400 VAC (No UL)
Motor Starter Direct,
up to 3.7 kW / 480 VAC (UL Approved)
Motor Starter Reversing,
up to 1.5 kW / 400 VAC (No UL)
Lifecycle Status
Active
Active
Active
Number of Points
N/A
N/A
N/A
Connection Style
3 - Phase
3 - Phase
3 - Phase
Output Voltage
400 VAC
480 VAC (±10%)
400 VAC
187 VAC to 440 VAC
187 VAC to 519 VAC
187 VAC to 440 VAC
50/60Hz
50/60Hz
50/60Hz
0.2 to 3.6 A
0.2 to 8.0 A
0.2 to 3.6 A
Electronic - Configurable
Over Current
Electronic - Configurable
Over Current
Electronic - Configurable
Over Current
Electronic
Mechanical Contactor
Electronic
45 mA
50 mA
45 mA
LED Indicators
Bus Diagnostics, Motor Protection
(group error message), Motor (on/off),
Manual Mode (on/off)
Bus Diagnostics, Motor Protection
(group error message), Motor (on/off),
Manual Mode (on/off)
Bus Diagnostics, Motor Protection
(group error message), Motor (on/off),
Manual Mode (on/off)
Required Terminal Strip
(1) IC220ACC105 (Contains 10 strips)
and (1) IC220ACC103 or IC220ACC104
(1) IC220ACC105 (Contains 10 strips)
and (1) IC220ACC103 or IC220ACC104
(1) IC220ACC105 (Contains 10 strips)
and (1) IC220ACC103 or IC220ACC104
Power Voltage Range
Frequency
Motor Current Range
Protection
Switching Method
Current Consumption
from Local Bus UL (mA)
3.64
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaPoint and VersaSafe I/O
Serial Communications Modules
The serial interface modules enable the VersaPoint to connect to serial devices via RS-232 or
RS-485/422. The modules support the following features:
•Serial I/O channel • Supports DTR/CTS handshake
•Supports various protocols
• Baud rate adjustable up to 38400 baud
•Adjustable number of data bits, stop bits, • Configuration and data exchange using
and parity PCP communications services.
•4 kbyte receive buffer, 1 kbyte transmit buffer • LED diagnostic and status indicators
IC220BEM232
IC220BEM485
Product Name
RS-232 Communications Module
interfaces serial I/O devices to a
VersaPoint I/O Station.
RS-485/422 Communications Module
interfaces serial I/O devices to a
VersaPoint I/O Station.
Lifecycle Status
Active
Active
1
1
Number of Points
Connection Style
Protocol
Data Rate
Data Buffer
Current Consumption
for Local Bus UL (mA)
LED Indicators
Required Terminal Strip
www.ge-ip.com
RS-232
RS-485 half duplex/422 full duplex
Transparent, End-to-end,
Dual buffer, 3964R, XON/XOFF
Transparent, End-to-end,
Dual buffer, 3964R, XON/XOFF,
Modbus RTU, Modbus ASCII
110, 300, 600, 1200, 1800, 2400,
4800, 9600, 19200, 38400
110, 300, 600, 1200, 1800, 2400,
4800, 9600, 19200, 38400
4-kbyte receive buffer and
1-kbyte transmit buffer
4-kbyte receive buffer and
1-kbyte transmit buffer
155 mA typical, 225 mA maximum
170 mA typical, 260 mA maximum
Bus Diagnostics,
Transmit and Receive
Bus Diagnostics,
Transmit and Receive
IC220TBK203
IC220TBK203
GE Intelligent Platforms Control Systems Solutions
3.65
VersaPoint and VersaSafe I/O
Industrial I/O
Accessories and Cables
IC220ACC001
Module Labels Narrow, Qty 10
Active
IC220ACC002
Module Labels Wide, Qty 10
Active
IC220ACC003
Point Labels Numbered 1-100, Qty 10
Active
IC220ACC004
Point Labels Blank, Qty 1000
Active
IC220ACC005
Module Keying Tabs, Qty 100
Active
IC220ACC100
Motor Starter Brake Module DC
Active
IC220ACC101
Motor Starter Brake Module AC/DC
Active
IC220ACC103
Motor Starter Power Connector
Active
IC220ACC104
Motor Starter Power Bridge
Active
IC220ACC105
Motor Circuit Connector, Qty 10
Active
IC220ACC201
Relay Module Isolation Set (Requires 1 IC220TBK206)
Active
IC220DEM001
VersaPoint Demo Case, DEVICENET NIU
Active
IC220DEM002
VersaPoint Demo Case, PROFIBUS NIU
Active
IC220DEM011
VersaPoint Static Demo, DEVICENET NIU
Active
IC220DEM012
VersaPoint Static Demo, PROFIBUS NIU
Active
IC220TBK061
I/O W/Shield, 6 Position Spring Style, Qty 5
Active
IC220TBK062
I/O Terminal Strip W/Dual Shield, 6 Position Spring Style, Qty 5
Active
IC220TBK082
I/O Terminal Strip, 8 Position Spring Style, Qty 10
Active
IC220TBK083
I/O Terminal Strip, 8 Position Spring Style, AC Input, Qty 10
Active
IC220TBK084
I/O Terminal Strip, 8 Position Spring Style, AC Output, Qty 10
Active
IC220TBK085
I/O Terminal Strip, 8 Position Spring Style, Relay, Qty 10
Active
IC220TBK087
Power Terminal Strip, 8 Position Spring Style, Qty 10
Active
IC220TBK122
I/O Terminal Strip, 12 Position Spring Style, Input, Qty 10
Active
IC220TBK123
I/O Terminal Strip, 12 Position Spring Style, Output, Qty 10
Active
IC220TBK201
Terminal Strip Set, Spring Style, DEVICENET NIU
Active
IC220TBK202
Terminal Strip Set, Spring Style, Encoder
Active
IC220TBK203
Terminal Strip Set, Spring Style, Analog Out/HSC
Active
IC220TBK204
Terminal Strip Set, Spring Style, AC Power Terminal
Active
IC220TBK206
Terminal Strip Set, Spring Style, Relay Isolation
Active
3.66
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaPoint and VersaSafe I/O
Configuration Guidelines
When configuring a VersaPoint the following guidelines should be considered:
1. VersaPoint is limited to 63 modules per Network Interface Unit.
2. Each module requires a terminal strip.
3.
Each voltage requires a Power Terminal to separate voltages.
4.
Segment Terminals can be used to easily group points within a voltage segment.
5.
Internal power/current rating of connectors is 2 amps. A power terminal is required if this rating is exceeded.
Cable Selection
Examples of Typical Application
Configuration for Controller (Example application requiring (120) 24 VDC inputs and (80) Relay outputs AC power supply) for local control. System also has five remote
cabinets, with each cabinet requiring (8) 24 VDC Inputs, (4) 24 VDC 0.5 Amp, Source Outputs and (2) current inputs and (2) current outputs (24 VDC power source) over Profibus DP.
Control Cabinet
Backplane Slots
Required
Power Supply
Current Required (mA)
2
1250 mA @ 3.3 VDC; 1000 mA @ 5 VDC
Qty
Part Number
Description
1
IC695CPU310
CPU with two built-in serial ports
1
IC695PSA040
120/240 VAC, 125 VDC Power Supply, current available
9 Amps @ 3.3 VDC; 6 Amps @ 5 VDC; 1.6 Amps @ 24 VDC maximum
600 mA @ 3.3 VDC; 240 mA @ 5 VDC
1
IC695CHS016
16 Slot Universal Base
4
1200 mA @ 5V
4
IC694MDL660
Discrete Input Module, 24 VDC Positive Logic, 32 points
(Requires terminal block)
5
35 mA @ 5V; 110 mA @ 24 VDC Relay
5
IC694MDL940
Discrete Output Module, Relay 2.0 A per point Form A, 16 points
(Terminal block included).
4
IC694TBB032
Terminal Block, Box Style
1
420 mA @ 5 VDC
1
IC695PBM300
Profibus DP Master Module
1
BC646MPP001
Logic Developer - PLC Professional
14
Total current from power supply required: 2895 mA @ 5V; 1850 @ 3.3V; 110 mA @ 24 VDC Relay. Only one power supplied needed.
2
Remote Cabinets (Qty 5)
5
IC220PBI001
PROFIBUS-DP Network Interface Unit (Requires 1 IC220TBK087)
5
IC220MDL643
Input, 24 VDC Positive Logic, 8pt (Requires 4 IC220TBK082)
5
IC220MDL752
Output, 24 VDC Positive Logic 0.5A, 4pt (Requires 1 IC220TBK123)
5
IC220ALG220
Analog In, 15 Bit, Voltage/Current, 2ch (Requires 1 IC220TBK061)
10
IC220ALG320
Analog Out, 16 Bit, Voltage/Current, 1ch (Requires 1 IC220TBK203)
5
IC220PWR003
Power Terminal, Fused with diag 24 VDC Requires 1 IC220TBK087)
1
IC220TBK087
Power Terminal Strip, 8 Position Spring Style, Qty 10
2
IC220TBK082
I/O Terminal Strip, 8 Position Spring Style, Qty 10
1
IC220TBK123
I/O Terminal Strip, 12 Position Spring Style, Output, Qty 10
1
IC220TBK061
I/O Terminal Strip with Shield, 6 Position Spring Style, Qty 5
1
IC220TBK203
Terminal Strip Set, Spring Style, Analog Out/HSC
1
IC695ETM001
RX3i Ethernet module 10/100 Mbits 2 RJ45 connections one
IP address occupies one slot on system base
6
IC690PWR024
24 VDC, 5 Amp Output Power and 120/230 VAC Input Power Power Supply
1
IC693ACC302
RX3i Long term battery for CPU
1
IC754VSI06STD
QuickPanel View Intermediate 6 inch STN Touch Operator Interface
Options to Consider
840 mA @ 3.3 VDC; 614 mA @ 5 VDC
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.67
VersaMax IP
Industrial I/O
VersaMax IP
VersaMax IP is designed to offer the
ruggedness and reliability of a standard
I/O system installed in a NEMA 4 cabinet, without the cost and effort to build
the cabinet. VersaMax IP is IP67 rated
so it can be bolted right to the equipment it controls without the need for an
enclosure. I/O, communications, and
power connections are made to the
blocks with off-the-shelf cordsets –
reducing design and installation time
and possible wiring errors.
Once installed, VersaMax IP’s diagnostics make troubleshooting a snap. In
the event of a failure, the connectorstyle wiring interface comes into play
Stand Alone Input and Output Modules
VersaMax IP Modular
once again, greatly reducing replacement time and the possibility of wiring
errors.
The initial release of VersaMax IP
includes Profibus I/O blocks, Profibus
Cordsets, and Power Cordsets. The
Profibus I/O blocks provide the following:
• Connection to Profibus-DP using M12
connectors
• Baud rates up to 12 MB – autoselect
• Connections to digital sensors using
M12 connectors (Input Blocks)
• Connection to digital actuators using
M12 connectors, each with load
capacity up to 2A (Output Blocks)
• Flexible voltage supply
• Diagnostics and Status indicators
• Short Circuit and Overload protection
of Sensor Supply and/or outputs
• IP65 and IP67 Protection
• Operating Temperature: -25°C to 60°C
Proficy Machine Edition
Proficy Machine Edition is an
advanced software environment for
the development and maintenance
of machine level automation.
Visualization, motion control, and
­execution logic are developed with
a single programmer.
page 3.69
pages 3.70-3.71
Accessories and Cables
page 3.72
Configuration Guidelines
page 3.73
Publication Reference Chart
GFK-2307
3.68
VersaMax IP Installation Manual
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax IP
Stand Alone Input and Output Modules
VersaMax IP modules are designed for distributed automation tasks in harsh environmental
conditions. Modules meet the requirements for both IP65/IP67 protection. They enable the
direct connection of sensors and actuators in an environment close to the station. Every
VersaMax IP device is connected directly to the bus system.
IC676PBI008
IC676PBI016
IC676PBM442
IC676PBO082
Product Name
8 Point Input Module,
Profibus
16 Point Input Module,
Profibus
4 Point Input and 4 Point
(2 Amp) Output Module,
Profibus
8 Point (2 Amp) Output
Module, Profibus
Lifecycle Status
Active
Active
Active
Active
Profibus DP
Profibus DP
Profibus DP
Profibus DP
24 VDC
24 VDC
24 VDC
24 VDC
Module Power Range
18 VDC to 30 VDC
18 VDC to 30 VDC
18 VDC to 30 VDC
18 VDC to 30 VDC
Module Current Consumption UL
at 24VDC
35mA typical,
100mA maximum
35mA typical,
100mA maximum
40mA typical,
100mA maximum
40mA typical,
100mA maximum
Module Current Consumption US
at 24 VDC
4.5mA typical plus sensor
current 700mA maximum
8mA typical plus sensor
current 1.2A maximum
4.5mA typical plus sensor
current 700mA maximum
3mA typical plus sensor
current 700mA maximum
N/A
N/A
6mA typical plus actuator
current, 4A maximum
12mA typical plus actuator
current, 4A maximum
2-, 3-, and 4-wire
2-, 3-, and 4-wire
(Y connector to support two
sensors per connector)
2- or 3-wire
2- or 3-wire
Range: -25°C to +60°C
(-13°F to +131°F)
Range: -25°C to +60°C
(-13°F to +131°F)
Range: -25°C to +60°C
(-13°F to +131°F)
Range: -25°C to +60°C
(-13°F to +131°F)
95%. Slight condensation
is permitted occasionally
on the outer housing,
for short periods
95%. Slight condensation
is permitted occasionally
on the outer housing,
for short periods
95%. Slight condensation
is permitted occasionally
on the outer housing,
for short periods
95%. Slight condensation
is permitted occasionally
on the outer housing,
for short periods
IP65 and IP67
according to IEC 60529
IP65 and IP67
according to IEC 60529
IP65 and IP67
according to IEC 60529
IP65 and IP67
according to IEC 60529
60mm x 160mm x 44.5mm
60mm x 160mm x 44.5mm
60mm x 178mm x 49.3mm
60mm x 178mm x 49.3mm
Protocol
Module Power
Module Current Consumption UAXX
at 24VDC
Connection Style (M12)
Operating Temperature
Degree of Protection
Class of Protection
Housing Dimensions (WxHxD)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.69
VersaMax IP
Industrial I/O
VersaMax IP Modular
VersaMax IP Modular modules are designed for distributed automation tasks in harsh
­environmental conditions. Modules meet the requirements for both IP65/IP67 protection.
They enable the direct connection of sensors and actuators in an environment close to
the station. Every VersaMax IP device is connected directly to the bus system. Up to
16 expansion modules can be connected to one Profibus VersaMax IP Modular local bus
master, supporting up to 136 digital or 64 analog signals or a combination of the two.
Product Name
IC677PBI001
IC677DBI008
IC677DBO085
Profibus VersaMax IP Modular local
bus master with (8) 24 VDC inputs
Expansion VersaMax IP Modular
slave with (8) 24 VDC inputs
Expansion VersaMax IP Modular
slave with (8) 24 VDC outputs
Active
Active
Active
Profibus DP
Profibus DP
Profibus DP
Lifecycle Status
Protocol
Number of Points
Module Power
Module Power Range
8
8
8
24 VDC
24 VDC
24 VDC
18 VDC to 30 VDC
18 VDC to 30 VDC
18 VDC to 30 VDC
75mA typical, 100mA maximum
35mA typical (50mA maximum)
@ 500Kbaud;
40mA typical (50mA maximum)
@ 2Mbaud
40mA typical (50mA maximum)
@ 500Kbaud;
45mA typical (50mA maximum)
@ 2Mbaud
15mA typical plus sensor current
600mA maximum
5mA typical plus sensor current
600mA maximum
5mA typical plus actuator current
600mA maximum
12mA typical plus actuator current,
4A maximum
N/A
N/A
2-, 3-, and 4-wire
(Y connector to support
two sensors per connector)
2-, 3-, and 4-wire
2-, 3-, and 4-wire
Connection Style (M12)
Operating Temperature
Range: -25°C to +60°C
(-13°F to +131°F)
Range: -25°C to +60°C
(-13°F to +131°F)
Range: -25°C to +60°C
(-13°F to +131°F)
Degree of Protection
95%. Slight condensation is permitted
occasionally on the outer housing,
for short periods
95%. Slight condensation is permitted
occasionally on the outer housing,
for short periods
95%. Slight condensation is permitted
occasionally on the outer housing,
for short periods
Class of Protection
IP65 and IP67 according to IEC 60529
IP65 and IP67 according to IEC 60529
IP65 and IP67 according to IEC 60529
70mm x 178mm x 49.3mm
70mm x 178mm x 49.3mm
70mm x 178mm x 49.3mm
Module Current Consumption UL
at 24 VDC
Module Current Consumption US
at 24 VDC
Module Current Consumption UAXX
at 24 VDC
Housing Dimensions (WxHxD)
3.70
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax IP
VersaMax IP Modular
VersaMax IP Modular modules are designed for distributed automation tasks in harsh
­environmental conditions. Modules meet the requirements for both IP65/IP67 protection.
They enable the direct connection of sensors and actuators in an environment close to
the station. Every VersaMax IP device is connected directly to the bus system. Up to
16 expansion modules can be connected to one Profibus VersaMax IP Modular local bus
master, supporting up to 136 digital or 64 analog signals or a combination of the two.
IC677DBM442
IC677ABI004
IC677ABO004
Expansion VersaMax IP Modular
slave with (4) 24VDC inputs and
4 outputs (2 amp)
Expansion VersaMax IP Modular
slave with (4) analog inputs
Expansion VersaMax IP Modular
slave with (4) analog outputs
Active
Active
Active
Protocol
Profibus DP
Profibus DP
Profibus DP
Number of Points
4 In/ 4 Out
4
4
Product Name
Lifecycle Status
Module Power
24 VDC
24 VDC
24 VDC
18 VDC to 30 VDC
18 VDC to 30 VDC
18 VDC to 30 VDC
40mA typical (50mA maximum)
@ 500Kbaud;
45mA typical (50mA maximum)
@ 2Mbaud
70 mA, typical
70 mA, typical
Module Current Consumption UL
at 24 VDC
Module Current Consumption US
at 24 VDC
5mA typical plus sensor current
600mA maximum
500mA typical plus sensor current
400mA maximum
5mA typical plus actuator current
400mA maximum
3mA typical plus actuator current,
4A maximum
N/A
N/A
Connection Style (M12)
2-, 3-, and 4-wire for sensor;
2 or 3-wire actuator control
2 or 4 wire technology (shielded)
2 or 4 wire technology (shielded)
Operating Temperature
Range: -25°C to +60°C
(-13°F to +131°F)
Range: -25°C to +60°C
(-13°F to +131°F)
Range: -25°C to +60°C
(-13°F to +131°F)
Degree of Protection
95%. Slight condensation is permitted
occasionally on the outer housing,
for short periods
95%. Slight condensation is permitted
occasionally on the outer housing,
for short periods
95%. Slight condensation is permitted
occasionally on the outer housing,
for short periods
Class of Protection
IP65 and IP67 according to IEC 60529
IP65 and IP67 according to IEC 60529
IP65 and IP67 according to IEC 60529
70mm x 178mm x 49.3mm
70mm x 178mm x 49.3mm
70mm x 178mm x 49.3mm
Module Power Range
Module Current Consumption UAXX
at 24 VDC
Housing Dimensions (WxHxD)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.71
VersaMax IP
Industrial I/O
Accessories and Cables
IC676ACC001
VersaMax IP Point Labels - Qty 50
Active
IC676ACC002
Protective Caps -Male (For unused I/O connectors and/or outgoing bus & power connectors) - Qty 5
Active
IC676ACC003
Protective Caps -Female (For unused incoming power connectors) - Qty 5
Active
IC676ACC004
Profibus Network Termination Resistor
Active
IC676ACC005
Profibus Network Tee
Active
IC676CBLPBB003
IP67 Profibus Cordset - 0.3 Meters
Active
IC676CBLPBB005
IP67 Profibus Cordset - 0.5 Meters
Active
IC676CBLPBB010
IP67 Profibus Cordset -1 Meter
Active
IC676CBLPBB020
IP67 Profibus Cordset - 2 Meters
Active
IC676CBLPBB050
IP67 Profibus Cordset - 5 Meters
Active
IC676CBLPBB100
IP67 Profibus Cordset - 10 Meters
Active
IC676CBLPBF020
IP67 Profibus Cordset - 2 Meters - Female Connector w/Leads
Active
IC676CBLPBF050
IP67 Profibus Cordset - 5 Meters - Female Connector w/Leads
Active
IC676CBLPBF100
IP67 Profibus Cordset - 10 Meters -Female Connector w/Leads
Active
IC676CBLPBM020
IP67 Profibus Cordset - 2 Meters, Male Connector w/Leads
Active
IC676CBLPBM050
IP67 Profibus Cordset - 5 Meters, Male Connector w/Leads
Active
IC676CBLPBM100
IP67 Profibus Cordset - 10 Meters -Male Connector w/Leads
Active
IC676CBLPWB003
IP67 Power Cordset - 0.3 Meters
Active
IC676CBLPWB005
IP67 Power Cordset - 0.5 Meters
Active
IC676CBLPWB010
IP67 Power Cordset -1 Meter
Active
IC676CBLPWB020
IP67 Power Cordset - 2 Meters
Active
IC676CBLPWB050
IP67 Power Cordset - 5 Meters
Active
IC676CBLPWB100
IP67 Power Cordset -10 Meters
Active
IC676CBLPWF020
IP67 Power Cordset - 2 Meters - Female Connector w/Leads
Active
IC676CBLPWF050
IP67 Power Cordset - 5 Meters - Female Connector w/Leads
Active
IC676CBLPWF100
IP67 Power Cordset -10 Meters -Female Connector w/Leads
Active
IC676CBLPWM020
IP67 Power Cordset - 2 Meters - Male Connector w/Leads
Active
IC676CBLPWM050
IP67 Power Cordset - 5 Meters - Male Connector w/Leads
Active
IC676CBLPWM100
IP67 Power Cordset -10 Meters - Male Connector w/Leads
Active
VersaMax IP Modular Inter-connection Cables
IC677CBLPWB0013
IP67 Voltage supply cable for local bus; A-coded, 5 position, unshielded 13.5 cm.
Active
IC677CBLLBB0013
IP67 Local communications cable for local bus; B-coded, 5 position, shielded 13.5 cm.
Active
3.72
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
VersaMax IP
Configuration Guidelines
When configuring a VersaMax IP the following guidelines should be considered
1.
Remember to select the proper cord set and termination resistor
2.
VersaMax IP Modular can support up to 16 Modular expansions with a total expansion length of 20 meters
Examples of Typical Application
Configuration for Controller (Example application requiring (120) 24VDC inputs and (80) Relay outputs AC power supply) for local control. System also has five remote
drops that will be mounted external to the machine. Each remote drop requires (8) 24VDC Inputs, (4) 24VDC 0.5 Amp, Source Outputs and (2) current inputs and (2) current outputs
(24VDC power source) over Profibus DP.
Control Cabinet
Backplane Slots
Required
Power Supply
Current Required (mA)
2
1250 mA @ 3.3 VDC; 1000mA @ 5 VDC
2
Qty
Part Number
Description
1
IC695CPU310
CPU with two built-in serial ports
1
IC695PSA040
120/240 VAC, 125 VDC Power Supply, current available
9 Amps @ 3.3 VDC; 6 Amps @ 5 VDC; 1.6 Amps @ 24 VDC maximum
600 mA @ 3.3 VDC; 240 mA @ 5 VDC
1
IC695CHS016
16 Slot Universal Base
4
1200 mA @ 5V
4
IC694MDL660
Discrete Input Module, 24 VDC Positive Logic, 32 points
(Requires terminal block)
5
35 mA @ 5V; 110mA @ 24 VDC Relay
5
IC694MDL940
Discrete Output Module, Relay 2.0 A per point Form A, 16 points
(Terminal block included).
4
IC694TBB032
Terminal Block, Box Style
1
420 mA @ 5 VDC
1
IC695PBM300
Profibus DP Master Module
1
BC646MPP001
Logic Developer -PLC Professional
14
Total current from power supply required: 2895mA @ 5V; 1850 @ 3.3V; 110mA @ 24 VDC Relay. Only one power supplied needed.
Remote Cabinets (Qty 5)
5
IC677PBI001
Profibus VersaMax IP Modular local bus master with (8) 24 VDC inputs
5
IC677DBO085
Expansion VersaMax IP Modular slave with (8) 24 VDC outputs
5
IC677ABI004
Expansion VersaMax IP Modular slave with (4) analog inputs
5
IC677ABO004
Expansion VersaMax IP Modular slave with (4) analog outputs
5
IC676CBLPBB100
IP67 Profibus Cordset -10 Meters
5
IC676CBLPWB100
IP67 Power Cordset -10 Meters
15
IC677CBLPWB0013
IP67 Voltage supply cable for local bus; A-coded, 5 position,
unshielded 13.5 cm.
15
IC677CBLLBB0013
IP67 Local communications cable for local bus; B-coded, 5 position,
shielded 13.5 cm.
1
IC695ETM001
RX3i Ethernet module 10/100 Mbits 2 RJ45 connections one
IP address occupies one slot on system base
6
IC690PWR024
24 VDC, 5 Amp Output Power and 120/230 VAC Input Power Power Supply
1
IC693ACC302
RX3i Long term battery for CPU
1
IC754VSI06STD
QuickPanel View Intermediate 6 inch STN Touch Operator Interface
Options to Consider
840mA @ 3.3 VDC; 614 mA @ 5 VDC
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.73
RSTi
Industrial I/O
RSTi
The new RSTi I/O system is Profinet enabled and ideal for distributed control applications. The compact, granular “build as you
go” design of the RSTi enables the user to optimize the design of the system and therefore minimize cost.
The RSTi is also Network Independent with over 10 different bus interfaces available such as Profibus, Modbus (serial and
Ethernet), EthernetIP, EtherCAT, CANopen, and CCLink. The RSTi is supported by over 80 discrete, analog, motion and specialty
I/O modules to address simple to complex applications.
Benefits of RSTi
• Network Independence: OEMs and
System Integrators can standardize
on their I/O layout without worrying
about the controller it is connected
to.
• Reduced Development Time: Panels can be fabricated in advance,
independent of the control system, by
simply changing out the network/bus
interface without impact to wiring.
• Reduced Installation Cost: Distributed I/O networks reduce
installation and wiring cost.
• Lower Cost Per Point: The RSTi can
be configured to meet application
needs. The granular design reduces
panel space and module cost.
• System Simplification: The
distributed nature of the RSTi greatly
reduces the time to dis-assemble and
re-assemble a machine, therefore
reducing machine commissioning.
• “Build as You Go”: Expansion is
simple; just slide in a RSTi I/O module
without impacting the wiring back to
the main control panel.
The RSTi is ideal for distributed I/O systems with as a few 4 I/O per location or
hundreds of I/O.
Network Interfaces
pages 3.75-3.76
Network Interfaces
with Built-in I/O
pages 3.77-3.87
Discrete I/O Modules (Input)
pages 3.88-3.90
Discrete I/O Modules (Output)
pages 3.94-3.98
Analog I/O Modules (Input)
pages 3.91-3.93
Analog I/O Modules (Output)
pages 3.99-3.101
High Speed Counting
Serial Communications Modules pages 3.104-3.105
RTD Modules
Power Modules
Thermocouple Modules
Motion Control
Publication Reference Chart
pages 3.106-3.107
page 3.102
pages 3.110-3.112
page 3.103
pages 3.108-3.109
Expansion Modules
page 3.113
Configuration Tools
pages 3.114-3.115
GFK-2745
RSTi I/O User Manual
Accessories
page 3.116
GFK-2746
RSTi Network Adapter Manual
Typical Application
page 3.117
3.74
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Network Interfaces
RSTi offers a wide range of network interfaces for Ethernet, Fieldbuses and serial networks.
The network independence of the RSTi enables to user to be flexible on system layouts.
STXPNS001
STXPBS001
STXDNS001
STXCAN001
STXMBS001
Slave Network Interface
Slave Network Interface
Slave Network Interface
Slave Network Interface
Slave Network Interface
Active
Active
Target Release
April 2012
Target Release
October 2012
Target Release
April 2012
Slave Network Interface
Slave Network Interface
Slave Network Interface
Slave Network Interface
Slave Network Interface
PROFINET Ethernet
Profibus V1
DeviceNet
CANopen
Modbus RS-232
PROFINET RT
Freeze mode
Sync mode
Auto baud rate
Fail safe mode
I/O Slave Message
(Group 2 only slave)
Poll command.
Bit_strobe command
Cyclic command,
COS command
100Mbps
9.6K to 12Mbps
125K bits/s, 250Kbps,
500Kbps (Auto baud
rate selection)
10KBps to 1Mbps
1200 to 115.2Kbps
Total: Inputs 128bytes/
Outputs 128bytes
Total: Inputs 128bytes/
Outputs 128bytes
Total: Inputs 252bytes/
Outputs 252bytes Max.
Discrete I/O: 2016
Inputs/2016 Outputs
Max. Analog I/O: 126
Inputs/126 Outputs
Total: Inputs 64 bytes/
Outputs 64 bytes
Total: Inputs 252bytes/
Outputs 252bytes
Module Status
Network Status
I/O Status
Port 1 Link Activity
Port 2 Link Activity
Field Power Status
Module Status
Network Status
Expansion Module Status
Field Power Status
Module Status
Network Status
Expansion Module Status
Field Power Status
Module Status
Network Status
Expansion Module Status
Field Power Status
Module Status
Transmit Data
Received Data
Expansion Module Status
Field Power Status
Diagnostic Supported
Yes
Yes
Yes
Yes
Yes
Maximum Bus Length
100 meters
between nodes
100 meters to 1.2Km
depending on baud rate
Up to 500 meters
depending on baud rate
Maximum Number of
Nodes Supported
Limited by the IP address
100
64
99
1
Number of Expansion
I/O Supported
32
32
32
32
32
Two RJ-45 with
built-in switch
DB 9 connector (RS-485)
5 pin connector
5 pin connector
DB 9 connector (RS-232)
Proficy Machine Edition
or GSDML
GSM File
EDS File
EDS File
I/O Guide Pro
24 VDC
(11 VDC to 28.8 VDC)
24 VDC
(11 VDC to 28.8 VDC)
24 VDC
(11 VDC to 28.8 VDC)
24 VDC
(11 VDC to 28.8 VDC)
24 VDC
(11 VDC to 28.8 VDC)
Product Name
Lifecycle Status
Module Type
Field Busses/Device Networks
Protocol Supported
Features
Line or Star topology
Built-in Ethernet Switch
Baud Rate
I/O Data Size
LEDs
Interface Connector Type
Configuration Tool
Field Power Requirement
RTU and ASCII
15 meters
Power Dissipation
115 mA typical @ 24 VDC
60 mA typical @ 24 VDC
300 mA typical
100 mA typical @ 24 VDC
70 mA typical @ 24 VDC
Internal Power Used (5 VDC loading)
1.5 A @ Maximum 5 VDC
1.5 A @ Maximum 5 VDC
1.2 A @ Maximum 5 VDC
1.5 A @ Maximum 5 VDC
1.5 A @ Maximum 5 VDC
99 x 45 x 70
99 x 45 x 70
99 x 42 x 70
99 x 42 x 70
99 x 45 x 70
Dimensions (H x W x D) in mm
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.75
RSTi
Industrial I/O
Network Interfaces
RSTi offers a wide range of network interfaces for Ethernet, Fieldbuses and serial networks.
The network independence of the RSTi enables to user to be flexible on system layouts.
STXMBS002
STXECT001
STXEIP001
STXMBE001
Product Name
Slave Network Interface
Slave Network Interface
Slave Network Interface
Slave Network Interface
Lifecycle Status
Target Release
April 2012
Target Release
July 2012
Target Release
July 2012
Target Release
April 2012
Slave Network Interface
Slave Network Interface
Slave Network Interface
Slave Network Interface
Modbus RS-485
EtherCAT Ethernet
Ethernet/IP Ethernet
Modbus TCP Ethernet
RTU and ASCII
EtherCAT
16 IO message connections
64 CIP connections
64 Explicit message connections
8 Modbus/TCP, 4 HTTP,
BOOTP, TBD
Module Type
Field Busses/Device Networks
Protocol Supported
Built-in Ethernet Switch
Features
1200 to 115.2Kbps
100Mbps
10/100Mbps
10/100Mbps
Total: Inputs 252bytes/
Outputs 252bytes
Total: Inputs 252bytes/
Outputs 252bytes
Total: Inputs 252bytes/
Outputs 252bytes
Total: Inputs 252bytes/
Outputs 252bytes
Module Status
Transmit Data
Received Data
Expansion Module Status
Field Power Status
Module Status
Network Status
Expansion Module Status
Field Power Status
Module Status
Network Status
I/O Status
Link Activity
Field Power Status
Module Status
Network Status
I/O Status
Link Activity
Field Power Status
Yes
Yes
Yes
Yes
1200 meters
100 meters between
EtherCAT nodes
100 meters between nodes
100 meters between nodes
Maximum Number of
Nodes Supported
64
65,535
Limited by the IP address
Limited by the IP address
Number of Expansion
I/O Supported
32
32
32
32
DB 9 connector (RS-485)
Two RJ-45 with built-in switch
One RJ-45
One RJ-45
I/O Guide Pro
I/O Guide Pro
EDS File
I/O Guide Pro
24 VDC
(11 VDC to 28.8 VDC)
24 VDC
(16 VDC to 28.8 VDC)
24 VDC
(11 VDC to 28.8 VDC)
24 VDC
(11 VDC to 28.8 VDC)
Power Dissipation
70 mA typical @ 24 VDC
100 mA typical @ 24 VDC
60 mA typical @ 24 VDC
60 mA typical @ 24 VDC
Internal Power Used (5 VDC loading)
1.5 A @ Maximum 5 VDC
1.5 A @ Maximum 5 VDC
1.5 A @ Maximum 5 VDC
1.5 A @ Maximum 5 VDC
99 x 45 x 70
99 x 54.2 x 70
99 x 45 x 70
99 x 45 x 70
Baud Rate
I/O Data Size
LEDs
Diagnostic Supported
Maximum Bus Length
Interface Connector Type
Configuration Tool
Field Power Requirement
Dimensions (H x W x D) in mm
3.76
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Network Interfaces with Built-in I/O
The Profibus and DeviceNet Network Interfaces are also available with built-in I/O to
reduce cost and footprint. The network interfaces can be expanded and support all of
the RSTi I/O types.
Product Name
Lifecycle Status
Module Type
Field Busses/Device Networks
Protocol Supported
Features
Baud Rate
I/O Data Size
LEDs
Diagnostic Supported
Maximum Bus Length
Maximum Number of Nodes Supported
STXPBS032
Slave Network Interface with
32 Positive Logic Inputs Built-in
Active
STXPBS132
Slave Network Interface with
32 Negative Logic Inputs Built-in
Active
STXPBS232
Slave Network Interface with
32 Sink Outputs Built-in
Active
Slave Network Interface
Slave Network Interface
Slave Network Interface
Profibus V1
Freeze mode, Sync mode,
Auto baudrate, Fail safe mode
Profibus V1
Freeze mode, Sync mode,
Auto baudrate, Fail safe mode
Profibus V1
Freeze mode, Sync mode
Auto baudrate, Fail safe mode
Profibus DP Network Slave has
built-in 32 Positive Logic Inputs
with expansion support
9.6K to 12Mbps
Profibus DP Network Slave has
built-in 32 Negative Logic Inputs
with expansion support
9.6K to 12Mbps
Profibus DP Network Slave has
built-in 32 Sink Outputs
with expansion support
9.6K to 12Mbps
Total: Inputs 36 bytes/Outputs 36 bytes total Total: Inputs 36 bytes/Outputs 36 bytes total Total: Inputs 36 bytes/Outputs 36 bytes total
(4 bytes In/ 4 bytes Out for base module and (4 bytes In/ 4 bytes Out for base module and (4 bytes In/ 4 bytes Out for base module and
32 bytes In/32 bytes Out for expansion
32 bytes In/32 bytes Out for expansion
32 bytes In/32 bytes Out for expansion
modules); Discrete I/O: Maximum Discrete
modules); Discrete I/O: Maximum Discrete
modules); Discrete I/O: Maximum Discrete
I/O: 256 inputs/ 256 outputs; Analog I/O:
I/O: 256 inputs/ 256 outputs; Analog I/O:
I/O: 256 inputs/ 256 outputs; Analog I/O:
16 Channels In/ 16 Channels Out
16 Channels In/ 16 Channels Out
16 Channels In/ 16 Channels Out
Module Status, Network Status, I/O Status
Module Status, Network Status, I/O Status
Yes
Yes
100 meters to 1.2Km depending on baud rate 100 meters to 1.2Km depending on baud rate
Module Status, Network Status, I/O Status
Yes
100 meters to 1.2Km depending on baud rate
100
100
8
8
8
32
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
32
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
32
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
32 Point 24 VDC Positive Logic
32 Point 24 VDC Negative Logic
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
Input Impedance
~5.4K ohms
~5.4K ohms
Input Signal Delay
< 0.5msec
< 0.5msec
ON State: 9 VDC, OFF State: 5 VDC
ON State: 9 VDC, OFF State: 5 VDC
32
32
Number of Expansion I/O Supported
Number of Points
System Power Requirement
Field Power Requirement
Input Type
Input Voltage Range
Response Time (ms)
Trigger Voltage
Points per Common
100
< 0.3msec
Output Type
32
32 Point 24 VDC Negative Logic
Output Range
Nominal 0 VDC; 11 to 28.8 VDC
Short protection, Over Temperature
Protection, Over Current Limit
Protection
Minimum Output Load
0.5 Amps per point
Load Current per Point
Output Inrush Current
Polarity
Configuration Tool
Interface Connector Type
Power Dissipation
Sink
GSM File
GSM File
GSM File
DB 9 connector (RS-485)
DB 9 connector (RS-485)
DB 9 connector (RS-485)
50 mA typical @ 24 VDC
Spring Clamp Terminal Block
50 mA typical @ 24 VDC
Spring Clamp Terminal Block
50 mA typical @ 24 VDC
Spring Clamp Terminal Block
400 mA @ Maximum 5 VDC
400 mA @ Maximum 5 VDC
400 mA @ Maximum 5 VDC
99 x 83 x 70
99 x 83 x 70
99 x 83 x 70
Connector Type
Internal Power Used (5 VDC loading)
Dimensions (H x W x D) in mm
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.77
RSTi
Industrial I/O
Network Interfaces with Built-in I/O
The Profibus and DeviceNet Network Interfaces are also available with built-in I/O to
reduce cost and footprint. The network interfaces can be expanded and support all of
the RSTi I/O types.
Product Name
Lifecycle Status
Module Type
Field Busses/Device Networks
Protocol Supported
Features
Baud Rate
I/O Data Size
LEDs
Diagnostic Supported
Maximum Bus Length
Maximum Number of Nodes Supported
Number of Expansion I/O Supported
Number of Points
System Power Requirement
Field Power Requirement
STXPBS332
Slave Network Interface with
32 Source Outputs Built-in
Active
STXPBS016
Slave Network Interface with
16 Relay Outputs
Target Release July 2012
STXPBS116
Slave Network Interface with
16 Isolated Relay Outputs
Target Release July 2012
Slave Network Interface
Slave Network Interface
Slave Network Interface
Profibus V1
Freeze mode, Sync mode,
Auto baudrate, Fail safe mode
Profibus V1
Freeze mode, Sync mode,
Auto baudrate, Fail safe mode
Profibus V1
Freeze mode, Sync mode,
Auto baudrate, Fail safe mode
Profibus DP Network Slave has
built-in 32 Source Outputs
with expansion support
9.6K to 12Mbps
Profibus DP Network Slave has
built-in 16 Relay Outputs
with expansion support
9.6K to 12Mbps
Profibus DP Network Slave has
built-in 16 Isolated Relay Outputs
with expansion support
9.6K to 12Mbps
Total: Inputs 36 bytes/Outputs 36 bytes total
(4 bytes In/ 4 bytes Out for base module
and 32 bytes In/32 bytes Out for expansion
modules); Discrete I/O: Maximum Discrete
I/O: 256 inputs/ 256 outputs; Analog I/O:
16 Channels In/ 16 Channels Out
Total: Inputs 32bytes/Outputs 32bytes;
Discrete I/O: 256 inputs/ 256 outputs;
Analog I/O: 16 Channels In/
16 Channels Out
Total: Inputs 36 bytes/Outputs 36 bytes total
(4 bytes In/ 4 bytes Out for base module
and 32 bytes In/32 bytes Out for expansion
modules); Discrete I/O: Maximum Discrete
I/O: 256 inputs/ 256 outputs; Analog I/O:
16 Channels In/ 16 Channels Out
Module Status, Network Status, I/O Status
Module Status, Network Status, I/O Status
Module Status, Network Status, I/O Status
Yes
Yes
100 meters to 1.2Km depending on baud rate 100 meters to 1.2Km depending on baud rate
Yes
100 meters to 1.2Km depending on baud rate
100
100
8
8
100
8
32
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
< 0.3msec
10msec
10msec
Input Type
Input Voltage Range
Input Impedance
Input Signal Delay
Response Time (ms)
Trigger Voltage
Points per Common
Output Type
Output Range
Protection
32
4
1
32 Point 24 VDC Positive Logic
16 Point Relay
16 Isolated Relay
Nominal 24 VDC; 11 to 28.8 VDC
Short protection, Over Temperature
Protection, Over Current Limit
5 to 28.8 VDC, 48 VDC, 110 VDC, 250 VAC
5 to 28.8 VDC, 48 VDC, 110 VDC, 250 VAC
100 micro Amps, 100 millivolts VDC per point
2 Amps at 5 to 28.8 VDC, 0.8 Amps at
48 VDC, 0.5 Amps at 110 VDC,
2 Amps at 250 VAC
100 micro Amps, 100 millivolts VDC per point
2 Amps at 5 to 28.8 VDC, 0.8 Amps at
48 VDC, 0.5 Amps at 110 VDC,
2 Amps at 250 VAC
Minimum Output Load
Load Current per Point
0.5 Amps per point
Output Inrush Current
Polarity
Source
Configuration Tool
Interface Connector Type
Power Dissipation
GSM File
GSM File
GSM File
DB 9 connector (RS-485)
DB 9 connector (RS-485)
DB 9 connector (RS-485)
50 mA typical @ 24 VDC
Spring Clamp Terminal Block
50 mA typical @ 24 VDC
Spring Clamp Terminal Block
50 mA typical @ 24 VDC
Spring Clamp Terminal Block
400 mA @ Maximum 5 VDC
400 mA @ Maximum 5 VDC
400 mA @ Maximum 5 VDC
99 x 83 x 70
99 x 83 x 70
99 x 83 x 70
Connector Type
Internal Power Used (5 VDC loading)
Dimensions (H x W x D) in mm
3.78
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Network Interfaces with Built-in I/O
The Profibus and DeviceNet Network Interfaces are also available with built-in I/O to
reduce cost and footprint. The network interfaces can be expanded and support all of
the RSTi I/O types.
Product Name
Lifecycle Status
Module Type
Field Busses/Device Networks
Protocol Supported
STXPBS432
Slave Network Interface with 16 Positive
Logic Inputs and 16 Source Outputs
Active
STXPBS532
Slave Network Interface with 16 Negative
Logic Inputs and 16 Sink Outputs
Active
STXPBS824
Slave Network Interface with 16 Positive
Logic Inputs and 16 Relay Outputs
Target Release July 2012
Slave Network Interface
Slave Network Interface
Slave Network Interface
Profibus V1
Freeze mode, Sync mode,
Auto baudrate, Fail safe mode
Profibus V1
Freeze mode, Sync mode,
Auto baudrate, Fail safe mode
Profibus V1
Freeze mode, Sync mode,
Auto baudrate, Fail safe mode
9.6K to 12Mbps
9.6K to 12Mbps
9.6K to 12Mbps
Features
Baud Rate
I/O Data Size
LEDs
Diagnostic Supported
Maximum Bus Length
Maximum Number of Nodes Supported
Total: Inputs 36 bytes/Outputs 36 bytes total Total: Inputs 36 bytes/Outputs 36 bytes total Total: Inputs 36 bytes/Outputs 36 bytes total
(4 bytes In/ 4 bytes Out for base module
(4 bytes In/ 4 bytes Out for base module
(4 bytes In/ 4 bytes Out for base module
and 32 bytes In/32 bytes Out for expansion and 32 bytes In/32 bytes Out for expansion and 32 bytes In/32 bytes Out for expansion
modules); Discrete I/O: Maximum Discrete
modules); Discrete I/O: Maximum Discrete
modules); Discrete I/O: Maximum Discrete
I/O: 256 inputs/ 256 outputs; Analog I/O:
I/O: 256 inputs/ 256 outputs; Analog I/O:
I/O: 256 inputs/ 256 outputs; Analog I/O:
16 Channels In/ 16 Channels Out
16 Channels In/ 16 Channels Out
16 Channels In/ 16 Channels Out
Module Status, Network Status, I/O Status
Module Status, Network Status, I/O Status
Yes
Yes
100 meters to 1.2Km depending on baud rate 100 meters to 1.2Km depending on baud rate
Module Status, Network Status, I/O Status
Yes
100 meters to 1.2Km depending on baud rate
100
100
8
8
8
16 In/16 Out
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16 In/16 Out
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16 In/16 Out
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16 Point 24 VDC Positive Logic
16 Point 24 VDC Negative Logic
16 Point 24 VDC Positive Logic
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
Input Impedance
~5.4K ohms
~5.4K ohms
~5.4K ohms
Input Signal Delay
< 0.5msec
< 0.5msec
< 0.5msec
Number of Expansion I/O Supported
Number of Points
System Power Requirement
Field Power Requirement
Input Type
Input Voltage Range
Response Time (ms)
Trigger Voltage
Points per Common
Output Type
Output Range
Protection
< 0.3msec
< 0.3msec
10msec
ON State: 9 VDC OFF State: 5 VDC
ON State: 9 VDC OFF State: 5 VDC
ON State: 9 VDC OFF State: 5 VDC
16 for Inputs and 4 for Outputs
32
32
16 Point 24 VDC Positive Logic
16 Point 24 VDC Negative Logic
16 Point Relay
Nominal 24 VDC; 11 to 28.8 VDC
Short protection, Over Temperature
Protection, Over Current Limit
Nominal 24 VDC; 11 to 28.8 VDC
Short protection, Over Temperature
Protection, Over Current Limit
5 to 28.8 VDC, 48 VDC, 110 VDC, 250 VAC
0.5 Amps per point
0.5 Amps per point
Minimum Output Load
Load Current per Point
100
100 micro Amps, 100 millivolts VDC per point
2 Amps at 5 to 28.8 VDC, 0.8 Amps at 48 VDC,
0.5 Amps at 110 VDC, 2 Amps at 250 VAC
Output Inrush Current
Polarity
Configuration Tool
Interface Connector Type
Power Dissipation
Source
Sink
GSM File
GSM File
GSM File
DB 9 connector (RS-485)
DB 9 connector (RS-485)
DB 9 connector (RS-485)
50 mA typical @ 24 VDC
Spring Clamp Terminal Block
50 mA typical @ 24 VDC
Spring Clamp Terminal Block
50 mA typical @ 24 VDC
Spring Clamp Terminal Block
400 mA @ Maximum 5 VDC
400 mA @ Maximum 5 VDC
400 mA @ Maximum 5 VDC
99 x 83 x 70
99 x 83 x 70
99 x 83 x 70
Connector Type
Internal Power Used (5 VDC loading)
Dimensions (H x W x D) in mm
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.79
RSTi
Industrial I/O
Network Interfaces with Built-in I/O
The Profibus and DeviceNet Network Interfaces are also available with built-in I/O to
reduce cost and footprint. The network interfaces can be expanded and support all of
the RSTi I/O types.
Product Name
Lifecycle Status
Module Type
Field Busses/Device Networks
Protocol Supported
STXPBS924
STXPBS825
STXPBS925
Slave Network Interface with 16 Negative Slave Network Interface with 16 Positive Slave Network Interface with 16 Negative
Logic Inputs and 16 Relay Outputs
Logic Inputs and 16 Isolated Relay Outputs Logic Inputs and 16 Isolated Relay Outputs
Target Release July 2012
Target Release July 2012
Target Release July 2012
Slave Network Interface
Slave Network Interface
Slave Network Interface
Profibus V1
Freeze mode, Sync mode,
Auto baudrate, Fail safe mode
Profibus V1
Freeze mode, Sync mode,
Auto baudrate, Fail safe mode
Profibus V1
Freeze mode, Sync mode,
Auto baudrate, Fail safe mode
9.6K to 12Mbps
9.6K to 12Mbps
9.6K to 12Mbps
Features
Baud Rate
I/O Data Size
LEDs
Diagnostic Supported
Maximum Bus Length
Maximum Number of Nodes Supported
Total: Inputs 36 bytes/Outputs 36 bytes total Total: Inputs 36 bytes/Outputs 36 bytes total Total: Inputs 36 bytes/Outputs 36 bytes total
(4 bytes In/ 4 bytes Out for base module
(4 bytes In/ 4 bytes Out for base module
(4 bytes In/ 4 bytes Out for base module
and 32 bytes In/32 bytes Out for expansion and 32 bytes In/32 bytes Out for expansion and 32 bytes In/32 bytes Out for expansion
modules); Discrete I/O: Maximum Discrete
modules); Discrete I/O: Maximum Discrete
modules); Discrete I/O: Maximum Discrete
I/O: 256 inputs/ 256 outputs; Analog I/O:
I/O: 256 inputs/ 256 outputs; Analog I/O:
I/O: 256 inputs/ 256 outputs; Analog I/O:
16 Channels In/ 16 Channels Out
16 Channels In/ 16 Channels Out
16 Channels In/ 16 Channels Out
Module Status, Network Status, I/O Status
Module Status, Network Status, I/O Status
Yes
Yes
100 meters to 1.2Km depending on baud rate 100 meters to 1.2Km depending on baud rate
Module Status, Network Status, I/O Status
Yes
100 meters to 1.2Km depending on baud rate
100
100
8
8
8
16 In/16 Out
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16 In/16 Out
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16 In/16 Out
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16 Point 24 VDC Negative Logic
16 Point 24 VDC Positive Logic
16 Point 24 VDC Negative Logic
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
Input Impedance
~5.4K ohms
~5.4K ohms
~5.4K ohms
Input Signal Delay
< 0.5msec
< 0.5msec
< 0.5msec
10msec
10msec
10msec
ON State: 9 VDC, OFF State: 5 VDC
ON State: 9 VDC, OFF State: 5 VDC
ON State: 9 VDC, OFF State: 5 VDC
16 for Inputs and 1 for Outputs
16 for Inputs and 1 for Outputs
16 for Inputs and 1 for Outputs
16 Point Relay
16 Point Isolated Relay
16 Point Isolated Relay
5 to 28.8 VDC, 48 VDC, 110 VDC, 250 VAC
5 to 28.8 VDC, 48 VDC, 110 VDC, 250 VAC
5 to 28.8 VDC, 48 VDC, 110 VDC, 250 VAC
Number of Expansion I/O Supported
Number of Points
System Power Requirement
Field Power Requirement
Input Type
Input Voltage Range
Response Time (ms)
Trigger Voltage
Points per Common
Output Type
Output Range
100
Protection
Minimum Output Load
Load Current per Point
100 micro Amps, 100 millivolts VDC per point 100 micro Amps, 100 millivolts VDC per point 100 micro Amps, 100 millivolts VDC per point
2 Amps at 5 to 28.8 VDC, 0.8 Amps at 48 VDC, 2 Amps at 5 to 28.8 VDC, 0.8 Amps at 48 VDC, 2 Amps at 5 to 28.8 VDC, 0.8 Amps at 48 VDC,
0.5 Amps at 110 VDC, 2 Amps at 250 VAC
0.5 Amps at 110 VDC, 2 Amps at 250 VAC
0.5 Amps at 110 VDC, 2 Amps at 250 VAC
Output Inrush Current
Polarity
Configuration Tool
Interface Connector Type
Power Dissipation
GSM File
GSM File
GSM File
DB 9 connector (RS-485)
DB 9 connector (RS-485)
DB 9 connector (RS-485)
50 mA typical @ 24 VDC
Spring Clamp Terminal Block
50 mA typical @ 24 VDC
Spring Clamp Terminal Block
50 mA typical @ 24 VDC
Spring Clamp Terminal Block
400 mA @ Maximum 5 VDC
400 mA @ Maximum 5 VDC
400 mA @ Maximum 5 VDC
99 x 83 x 70
99 x 83 x 70
99 x 83 x 70
Connector Type
Internal Power Used (5 VDC loading)
Dimensions (H x W x D) in mm
3.80
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Network Interfaces with Built-in I/O
The Profibus and DeviceNet Network Interfaces are also available with built-in I/O to
reduce cost and footprint. The network interfaces can be expanded and support all of
the RSTi I/O types.
Product Name
Lifecycle Status
Module Type
Field Busses/Device Networks
Protocol Supported
STXDNS032
Slave Network Interface with
32 Positive Logic Inputs Built-in
Target Release April 2012
STXDNS132
Slave Network Interface with
32 Negative Logic Inputs Built-in
Target Release April 2012
STXDNC032
Slave Network Interface with
32 Positive Logic Inputs Built-in
Target Release April 2012
Slave Network Interface
Slave Network Interface
Slave Network Interface
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command”
Features
Baud Rate
I/O Data Size
LEDs
125K bits/s, 250Kbps, 500Kbps
125K bits/s, 250Kbps, 500Kbps
(Auto baud rate selection)
(Auto baud rate selection)
Total: Inputs 36 bytes/Outputs 34 bytes total Total: Inputs 36 bytes/Outputs 34 bytes total
(4 bytes In/ 4 bytes Out for base
(4 bytes In/ 4 bytes Out for base
module and 32 bytes In/30 bytes Out
module and 32 bytes In/30 bytes Out
for expansion modules)
for expansion modules)
125K bits/s, 250Kbps, 500Kbps
(Auto baud rate selection)
Total: Inputs 4 bytes/Outputs 4 bytes
Module Status, Network Status, I/O Status
Module Status, Network Status, I/O Status
Diagnostic Supported
Yes
Yes
Yes
Maximum Bus Length
Up to 500 meters depending on baud rate
Up to 500 meters depending on baud rate
Up to 500 meters depending on baud rate
Maximum Number of Nodes Supported
64
64
64
Number of Expansion I/O Supported
10
10
None Supported
32 In
24 VDC (19.2 to 28.8 VDC) with Current Limit,
Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
32 In
24 VDC (19.2 to 28.8 VDC) with Current Limit,
Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
32
24 VDC (11 VDC to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
32 Point 24 VDC Positive Logic
32 Point 24 VDC Negative Logic
32 Point 24 VDC Positive Logic
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
Input Impedance
~5.4K ohms
~5.4K ohms
~5.4K ohms
Input Signal Delay
< 0.5msec
< 0.5msec
< 0.5msec
ON State: 9 VDC, OFF State: 5 VDC
ON State: 9 VDC, OFF State: 5 VDC
ON State: 9 VDC, OFF State: 5VD
16 for Inputs and 1 for Outputs
16 for Inputs and 1 for Outputs
16
Number of Points
System Power Requirement
Field Power Requirement
Input Type
Input Voltage Range
Module Status, Network Status, I/O Status
Response Time (ms)
Trigger Voltage
Points per Common
Output Type
Output Range
Protection
Minimum Output Load
Load Current per Point
Output Inrush Current
Polarity
Configuration Tool
Interface Connector Type
Power Dissipation
EDS File
EDS File
EDS File
5 pin connector
5 pin connector
5 pin connector
110 mA typical
Spring Clamp Terminal Block
110 mA typical
Spring Clamp Terminal Block
80 mA typical
Connector Type
600 mA @ Maximum 5 VDC
600 mA @ Maximum 5 VDC
Not Applicable
99 x 83 x 70
99 x 83 x 70
80 x 35 x 55
Connector Type
Internal Power Used (5 VDC loading)
Dimensions (H x W x D) in mm
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.81
RSTi
Industrial I/O
Network Interfaces with Built-in I/O
The Profibus and DeviceNet Network Interfaces are also available with built-in I/O to
reduce cost and footprint. The network interfaces can be expanded and support all of
the RSTi I/O types.
Product Name
Lifecycle Status
Module Type
Field Busses/Device Networks
Protocol Supported
STXDNC132
Slave Network Interface with
32 Negative Logic Inputs Built-in
Target Release April 2012
STXDNS232
Slave Network Interface with
32 Sink Outputs Built-in
Target Release April 2012
STXDNS332
Slave Network Interface with
32 Source Outputs Built-in
Target Release April 2012
Slave Network Interface
Slave Network Interface
Slave Network Interface
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command
Features
Baud Rate
125K bits/s, 250Kbps, 500Kbps
(Auto baud rate selection)
Total: Inputs 4 bytes/Outputs 4 bytes
I/O Data Size
LEDs
125K bits/s, 250Kbps, 500Kbps
125K bits/s, 250Kbps, 500Kbps
(Auto baud rate selection)
(Auto baud rate selection)
Total: Inputs 36 bytes/Outputs 34 bytes total Total: Inputs 36 bytes/Outputs 34 bytes total
(4 bytes In/ 4 bytes Out for base
(4 bytes In/ 4 bytes Out for base
module and 32 bytes In/30 bytes Out
module and 32 bytes In/30 bytes Out
for expansion modules)
for expansion modules)
Module Status, Network Status, I/O Status
Module Status, Network Status, I/O Status
Diagnostic Supported
Yes
Yes
Yes
Maximum Bus Length
Up to 500 meters depending on baud rate
Up to 500 meters depending on baud rate
Up to 500 meters depending on baud rate
Maximum Number of Nodes Supported
Number of Expansion I/O Supported
Number of Points
System Power Requirement
Field Power Requirement
Input Type
Input Voltage Range
64
64
64
None Supported
10
10
32
24 VDC (11 VDC to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
32
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
32
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
< 0.3msec
< 0.3msec
32 Point 24 VDC Negative Logic
24 VDC (11 VDC to 28.8 VDC)
Input Impedance
~5.4K ohms
Input Signal Delay
< 0.5msec
Response Time (ms)
Trigger Voltage
Points per Common
Module Status, Network Status, I/O Status
ON State: 9 VDC, OFF State: 5 VDC
16
Output Type
Output Range
Protection
32
32
32 Point 24 VDC Negative Logic
32 Point 24 VDC Positive Logic
Nominal 0 VDC; 11 to 28.8 VDC
Short protection, Over Temperature
Protection, Over Current Limit
Nominal 24 VDC; 11 to 28.8 VDC
Short protection, Over Temperature
Protection, Over Current Limit
0.5 Amps per point
0.5 Amps per point
Minimum Output Load
Load Current per Point
Output Inrush Current
Polarity
Sink
Source
EDS File
EDS File
EDS File
Interface Connector Type
5 pin connector
5 pin connector
5 pin connector
Power Dissipation
80 mA typical
Connector Type
110 mA typical
Spring Clamp Terminal Block
110 mA typical
Spring Clamp Terminal Block
Not Applicable
600 mA @ Maximum 5 VDC
600 mA @ Maximum 5 VDC
80 x 35 x 55
99 x 83 x 70
99 x 83 x 70
Configuration Tool
Connector Type
Internal Power Used (5 VDC loading)
Dimensions (H x W x D) in mm
3.82
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Network Interfaces with Built-in I/O
The Profibus and DeviceNet Network Interfaces are also available with built-in I/O to
reduce cost and footprint. The network interfaces can be expanded and support all of
the RSTi I/O types.
Product Name
Lifecycle Status
Module Type
Field Busses/Device Networks
Protocol Supported
STXDNC232
Slave Network Interface with
32 Sink Outputs
Target Release April 2012
STXDNC332
Slave Network Interface with
32 Source Outputs
Target Release April 2012
STXDNS016
Slave Network Interface with
16 Relay Outputs
Target Release April 2012
Slave Network Interface
Slave Network Interface
Slave Network Interface
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command”
125K bits/s, 250Kbps, 500Kbps
(Auto baud rate selection)
Total: Inputs 4 bytes/Outputs 4 bytes
125K bits/s, 250Kbps, 500Kbps
(Auto baud rate selection)
Total: Inputs 4 bytes/Outputs 4 bytes
125K bits/s, 250Kbps, 500Kbps
(Auto baud rate selection)
Total: Inputs 36 bytes/Outputs 34 bytes
total (4 bytes In/ 4 bytes Out for base
module and 32 bytes In/30 bytes Out
for expansion modules)
Module Status, Network Status, I/O Status
Features
Baud Rate
I/O Data Size
LEDs
Module Status, Network Status, I/O Status
Module Status, Network Status, I/O Status
Diagnostic Supported
Yes
Yes
Yes
Maximum Bus Length
Up to 500 meters depending on baud rate
Up to 500 meters depending on baud rate
Up to 500 meters depending on baud rate
Maximum Number of Nodes Supported
Number of Expansion I/O Supported
Number of Points
System Power Requirement
Field Power Requirement
64
64
64
None Supported
None Supported
10
32
24 VDC (11 VDC to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
32
24 VDC (11 VDC to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
< 0.3msec
< 0.3msec
10msec
Input Type
Input Voltage Range
Input Impedance
Input Signal Delay
Response Time (ms)
Trigger Voltage
Points per Common
Output Type
Output Range
Protection
16
16
32 Point 24 VDC Negative Logic
32 Point 24 VDC Positive Logic
16 Point Relay
Nominal 24 VDC; 11 to 28.8 VDC
Short protection, Over Temperature
Protection, Over Current Limit
Nominal 24 VDC; 11 to 28.8 VDC
Short protection, Over Temperature
Protection, Over Current Limit
5 to 28.8 VDC, 48 VDC, 110 VDC, 250 VAC
0.5 Amps per point
0.5 Amps per point
Minimum Output Load
Load Current per Point
100 micro Amps, 100 millivolts VDC per point
2 Amps at 5 to 28.8 VDC, 0.8 Amps at 48
VDC, 0.5 Amps at 110 VDC,
2 Amps at 250 VAC
Output Inrush Current
Polarity
Configuration Tool
Interface Connector Type
Power Dissipation
Connector Type
Internal Power Used (5 VDC loading)
Dimensions (H x W x D) in mm
www.ge-ip.com
Sink
Source
EDS File
EDS File
EDS File
5 pin connector
5 pin connector
5 pin connector
80 mA typical
Connector Type Hirose, HIF3A-40D-2.54R
(ribbon cable), HIF2C-40D-2.54C (crimp con–
nector), HIF2C-2226SCFA (crimp pin) or equal
80 mA typical
Connector Type Hirose, HIF3A-40D-2.54R
(ribbon cable), HIF2C-40D-2.54C (crimp con–
nector), HIF2C-2226SCFA (crimp pin) or equal
110 mA typical
Spring Clamp Terminal Block
Not Applicable
Not Applicable
600 mA @ Maximum 5 VDC
80 x 35 x 55
80 x 35 x 55
99 x 83 x 70
GE Intelligent Platforms Control Systems Solutions
3.83
RSTi
Industrial I/O
Network Interfaces with Built-in I/O
The Profibus and DeviceNet Network Interfaces are also available with built-in I/O to
reduce cost and footprint. The network interfaces can be expanded and support all of
the RSTi I/O types.
Product Name
Lifecycle Status
Module Type
Field Busses/Device Networks
Protocol Supported
STXDNS116
Slave Network Interface with 16 Isolated
Relay Outputs
Target Release April 2012
STXDNS432
Slave Network Interface with 16 Positive
Logic Inputs and 16 Source Outputs
Target Release April 2012
STXDNS532
Slave Network Interface with 16 Negative
Logic Inputs and 16 Sink Outputs
Target Release April 2012
Slave Network Interface
Slave Network Interface
Slave Network Interface
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command”
Features
Baud Rate
I/O Data Size
LEDs
125K bits/s, 250Kbps, 500Kbps
125K bits/s, 250Kbps, 500Kbps
125K bits/s, 250Kbps, 500Kbps
(Auto baud rate selection)
(Auto baud rate selection)
(Auto baud rate selection)
Total: Inputs 36 bytes/Outputs 34 bytes total Total: Inputs 36 bytes/Outputs 34 bytes total Total: Inputs 36 bytes/Outputs 34 bytes total
(4 bytes In/ 4 bytes Out for base
(4 bytes In/ 4 bytes Out for base
(4 bytes In/ 4 bytes Out for base
module and 32 bytes In/30 bytes Out
module and 32 bytes In/30 bytes Out
module and 32 bytes In/30 bytes Out
for expansion modules)
for expansion modules)
for expansion modules)
Module Status, Network Status, I/O Status
Module Status, Network Status, I/O Status
Diagnostic Supported
Yes
Yes
Yes
Maximum Bus Length
Up to 500 meters depending on baud rate
Up to 500 meters depending on baud rate
Up to 500 meters depending on baud rate
Maximum Number of Nodes Supported
64
64
64
Number of Expansion I/O Supported
10
10
10
16
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16 In/ 16 Out
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16 In/ 16 Out
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16 Point 24 VDC Positive Logic
16 Point 24 VDC Negative Logic
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
Input Impedance
~5.4K ohms
~5.4K ohms
Input Signal Delay
< 0.5msec
< 0.5msec
Number of Points
System Power Requirement
Field Power Requirement
Input Type
Input Voltage Range
Response Time (ms)
10msec
Trigger Voltage
Points per Common
Output Type
Output Range
Load Current per Point
< 0.3msec
< 0.3msec
ON State: 9 VDC, OFF State: 5 VDC
ON State: 9 VDC, OFF State: 5 VDC
32
32
16 Point Isolated Relay
16 Point 24 VDC Positive Logic
16 Point 24 VDC Negative Logic
5 to 28.8 VDC, 48 VDC, 110 VDC, 250 VAC
Nominal 24 VDC; 11 to 28.8 VDC
Short protection, Over Temperature
Protection, Over Current Limit
Nominal 24 VDC; 11 to 28.8 VDC
Short protection, Over Temperature
Protection, Over Current Limit
100 micro Amps, 100 millivolts VDC per point
2 Amps at 5 to 28.8 VDC, 0.8 Amps at 48
VDC, 0.5 Amps at 110 VDC,
2 Amps at 250 VAC
0.5 Amps per point
0.5 Amps per point
Source
Sink
EDS File
EDS File
EDS File
5 pin connector
5 pin connector
5 pin connector
110 mA typical
Spring Clamp Terminal Block
110 mA typical
Spring Clamp Terminal Block
110 mA typical
Spring Clamp Terminal Block
600 mA @ Maximum 5 VDC
600 mA @ Maximum 5 VDC
600 mA @ Maximum 5 VDC
99 x 83 x 70
99 x 83 x 70
99 x 83 x 70
Protection
Minimum Output Load
Module Status, Network Status, I/O Status
Output Inrush Current
Polarity
Configuration Tool
Interface Connector Type
Power Dissipation
Connector Type
Internal Power Used (5 VDC loading)
Dimensions (H x W x D) in mm
3.84
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Network Interfaces with Built-in I/O
The Profibus and DeviceNet Network Interfaces are also available with built-in I/O to
reduce cost and footprint. The network interfaces can be expanded and support all of
the RSTi I/O types.
Product Name
Lifecycle Status
Module Type
Field Busses/Device Networks
Protocol Supported
STXDNC432
Slave Network Interface with 16 Positive
Logic Inputs and 16 Source Outputs
Target Release April 2012
STXDNC532
Slave Network Interface with 16 Negative
Logic Inputs and 16 Sink Outputs
Target Release April 2012
STXDNC632
Slave Network Interface with 16 Positive
Logic Inputs and 16 Sink Outputs
Target Release April 2012
Slave Network Interface
Slave Network Interface
Slave Network Interface
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command
125K bits/s, 250Kbps, 500Kbps
(Auto baud rate selection)
Total: Inputs 4 bytes/Outputs 4 bytes
125K bits/s, 250Kbps, 500Kbps
(Auto baud rate selection)
Total: Inputs 4 bytes/Outputs 4 bytes
125K bits/s, 250Kbps, 500Kbps
(Auto baud rate selection)
Total: Inputs 4 bytes/Outputs 4 bytes
Module Status, Network Status, I/O Status
Features
Baud Rate
I/O Data Size
LEDs
Module Status, Network Status, I/O Status
Module Status, Network Status, I/O Status
Diagnostic Supported
Yes
Yes
Yes
Maximum Bus Length
Up to 500 meters depending on baud rate
Up to 500 meters depending on baud rate
Up to 500 meters depending on baud rate
Maximum Number of Nodes Supported
64
64
64
None Supported
None Supported
None Supported
16 In/ 16 Out
24 VDC (11 VDC to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16 In/ 16 Out
24 VDC (11 VDC to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16 In/ 16 Out
24 VDC (11 VDC to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16 Point 24 VDC Positive Logic
16 Point 24 VDC Negative Logic
16 Point 24 VDC Positive Logic
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
Input Impedance
~5.4K ohms
~5.4K ohms
~5.4K ohms
Input Signal Delay
< 0.5msec
< 0.5msec
< 0.5msec
Response Time (ms)
< 0.3msec
< 0.3msec
< 0.3msec
ON State: 9 VDC, OFF State: 5 VDC
ON State: 9 VDC, OFF State: 5 VDC
ON State: 9 VDC, OFF State: 5 VDC
Number of Expansion I/O Supported
Number of Points
System Power Requirement
Field Power Requirement
Input Type
Input Voltage Range
Trigger Voltage
Points per Common
Output Type
Output Range
Protection
16
16
16
16 Point 24 VDC Positive Logic
16 Point 24 VDC Negative Logic
16 Point 24 VDC Positive Logic
Nominal 24 VDC; 11 to 28.8 VDC
Short protection, Over Temperature
Protection, Over Current Limit
Nominal 24 VDC; 11 to 28.8 VDC
Short protection, Over Temperature
Protection, Over Current Limit
Nominal 24 VDC; 11 to 28.8 VDC
Short protection, Over Temperature
Protection, Over Current Limit
0.5 Amps per point
0.5 Amps per point
0.5 Amps per point
Minimum Output Load
Load Current per Point
Output Inrush Current
Polarity
Source
Sink
Sink
Configuration Tool
EDS File
EDS File
EDS File
5 pin connector
5 pin connector
5 pin connector
80 mA typical
Connector Type Hirose, HIF3A-40D-2.54R
(ribbon cable), HIF2C-40D-2.54C (crimp connector), HIF2C-2226SCFA (crimp pin) or equal
80 mA typical
Connector Type Hirose, HIF3A-40D-2.54R
(ribbon cable), HIF2C-40D-2.54C (crimp connector), HIF2C-2226SCFA (crimp pin) or equal
80 mA typical
Connector Type Hirose, HIF3A-40D-2.54R
(ribbon cable), HIF2C-40D-2.54C (crimp connector), HIF2C-2226SCFA (crimp pin) or equal
Not Applicable
Not Applicable
Not Applicable
80 x 35 x 55
80 x 35 x 55
80 x 35 x 55
Interface Connector Type
Power Dissipation
Connector Type
Internal Power Used (5 VDC loading)
Dimensions (H x W x D) in mm
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.85
RSTi
Industrial I/O
Network Interfaces with Built-in I/O
The Profibus and DeviceNet Network Interfaces are also available with built-in I/O to
reduce cost and footprint. The network interfaces can be expanded and support all of
the RSTi I/O types.
Product Name
Lifecycle Status
Module Type
Field Busses/Device Networks
Protocol Supported
STXDNC732
Slave Network Interface with 16 Negative
Logic Inputs and 16 Source Outputs
Target Release April 2012
STXDNS824
Slave Network Interface with 16 Positive
Logic Inputs and 16 Relay Outputs
Target Release April 2012
STXDNS924
Slave Network Interface with 16 Negative
Logic Inputs and 16 Relay Outputs
Target Release April 2012
Slave Network Interface
Slave Network Interface
Slave Network Interface
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command
Features
Baud Rate
125K bits/s, 250Kbps, 500Kbps
(Auto baud rate selection)
Total: Inputs 4 bytes/Outputs 4 bytes
I/O Data Size
LEDs
125K bits/s, 250Kbps, 500Kbps
125K bits/s, 250Kbps, 500Kbps
(Auto baud rate selection)
(Auto baud rate selection)
Total: Inputs 36 bytes/Outputs 34 bytes total Total: Inputs 36 bytes/Outputs 34 bytes total
(4 bytes In/ 4 bytes Out for base
(4 bytes In/ 4 bytes Out for base
module and 32 bytes In/30 bytes Out
module and 32 bytes In/30 bytes Out
for expansion modules)
for expansion modules)
Module Status, Network Status, I/O Status
Module Status, Network Status, I/O Status
Diagnostic Supported
Yes
Yes
Yes
Maximum Bus Length
Up to 500 meters depending on baud rate
Up to 500 meters depending on baud rate
Up to 500 meters depending on baud rate
64
Maximum Number of Nodes Supported
Module Status, Network Status, I/O Status
64
64
None Supported
10
10
16 In/ 16 Out
24 VDC (11 VDC to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16 In/ 16 Out
24 VDC (19.2 to 28.8 VDC) with Current Limit,
Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16 In/ 16 Out
24 VDC (19.2 to 28.8 VDC) with Current Limit,
Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16 Point 24 VDC Negative Logic
16 Point 24 VDC Positive Logic
16 Point 24 VDC Negative Logic
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
Input Impedance
~5.4K ohms
~5.4K ohms
~5.4K ohms
Input Signal Delay
< 0.5msec
< 0.5msec
< 0.5msec
Response Time (ms)
< 0.3msec
10msec
10msec
ON State: 9 VDC, OFF State: 5 VDC
ON State: 9 VDC, OFF State: 5 VDC
ON State: 9 VDC, OFF State: 5 VDC
16 for Inputs and 1 for Outputs
Number of Expansion I/O Supported
Number of Points
System Power Requirement
Field Power Requirement
Input Type
Input Voltage Range
Trigger Voltage
Points per Common
Output Type
Output Range
Protection
16
16 for Inputs and 4 for Outputs
16 Point 24 VDC Negative Logic
16 Point Relay
16 Point Relay
Nominal 24 VDC; 11 to 28.8 VDC
Short protection, Over Temperature
Protection, Over Current Limit
5 to 28.8 VDC, 48 VDC, 110 VDC, 250 VAC
5 to 28.8 VDC, 48 VDC, 110 VDC, 250 VAC
Minimum Output Load
Load Current per Point
0.5 Amps per point
100 micro Amps, 100 millivolts VDC per point 100 micro Amps, 100 millivolts VDC per point
2 Amps at 5 to 28.8 VDC, 0.8 Amps at 48 VDC, 2 Amps at 5 to 28.8 VDC, 0.8 Amps at 48 VDC,
0.5 Amps at 110 VDC, 2 Amps at 250 VAC
0.5 Amps at 110 VDC, 2 Amps at 250 VAC
Output Inrush Current
Polarity
Source
Configuration Tool
EDS File
EDS File
EDS File
5 pin connector
5 pin connector
5 pin connector
80 mA typical
Connector Type Hirose, HIF3A-40D-2.54R
(ribbon cable), HIF2C-40D-2.54C (crimp connector), HIF2C-2226SCFA (crimp pin) or equal
110 mA typical
Spring Clamp Terminal Block
110 mA typical
Spring Clamp Terminal Block
Not Applicable
600 mA @ Maximum 5 VDC
600 mA @ Maximum 5 VDC
80 x 35 x 55
99 x 83 x 70
99 x 83 x 70
Interface Connector Type
Power Dissipation
Connector Type
Internal Power Used (5 VDC loading)
Dimensions (H x W x D) in mm
3.86
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Network Interfaces with Built-in I/O
The Profibus and DeviceNet Network Interfaces are also available with built-in I/O to
reduce cost and footprint. The network interfaces can be expanded and support all of
the RSTi I/O types.
Product Name
Lifecycle Status
Module Type
Field Busses/Device Networks
Protocol Supported
STXDNS825
Slave Network Interface with 16 Positive
Logic Inputs and 16 Isolated Relay Outputs
Target Release April 2012
STXDNS925
Slave Network Interface with 16 Negative
Logic Inputs and 16 Isolated Relay Outputs
Target Release April 2012
Slave Network Interface
Slave Network Interface
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command
DeviceNet
I/O Slave Message (Group 2 only slave),
Poll command. Bit_strobe command,
Cyclic command, COS command
Features
Baud Rate
I/O Data Size
LEDs
125K bits/s, 250Kbps, 500Kbps
125K bits/s, 250Kbps, 500Kbps
(Auto baud rate selection)
(Auto baud rate selection)
Total: Inputs 36 bytes/Outputs 34 bytes total Total: Inputs 36 bytes/Outputs 34 bytes total
(4 bytes In/ 4 bytes Out for base
(4 bytes In/ 4 bytes Out for base
module and 32 bytes In/30 bytes Out
module and 32 bytes In/30 bytes Out
for expansion modules)
for expansion modules)
Module Status, Network Status, I/O Status
Module Status, Network Status, I/O Status
Diagnostic Supported
Yes
Yes
Maximum Bus Length
Up to 500 meters depending on baud rate
Up to 500 meters depending on baud rate
Maximum Number of Nodes Supported
64
64
Number of Expansion I/O Supported
10
10
16 In/ 16 Out
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16 In/ 16 Out
24 VDC (19.2 to 28.8 VDC) with Current
Limit, Reverse Polarity Protection
24 VDC (11 VDC to 28.8 VDC)
16 Point 24 VDC Positive Logic
16 Point 24 VDC Negative Logic
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
Input Impedance
~5.4K ohms
~5.4K ohms
Input Signal Delay
< 0.5msec
< 0.5msec
Number of Points
System Power Requirement
Field Power Requirement
Input Type
Input Voltage Range
Response Time (ms)
Trigger Voltage
Points per Common
Output Type
Output Range
10msec
10msec
ON State: 9 VDC, OFF State: 5 VDC
ON State: 9 VDC, OFF State: 5 VDC
16 for Inputs and 1 for Outputs
16 for Inputs and 1 for Outputs
16 Point Isolated Relay
16 Point Isolated Relay
5 to 28.8 VDC, 48 VDC, 110 VDC, 250 VAC
5 to 28.8 VDC, 48 VDC, 110 VDC, 250 VAC
Protection
Minimum Output Load
Load Current per Point
100 micro Amps, 100 millivolts VDC per point 100 micro Amps, 100 millivolts VDC per point
2 Amps at 5 to 28.8 VDC, 0.8 Amps at 48 VDC, 2 Amps at 5 to 28.8 VDC, 0.8 Amps at 48 VDC,
0.5 Amps at 110 VDC, 2 Amps at 250 VAC
0.5 Amps at 110 VDC, 2 Amps at 250 VAC
Output Inrush Current
Polarity
Configuration Tool
Interface Connector Type
Power Dissipation
EDS File
EDS File
5 pin connector
5 pin connector
110 mA typical
Spring Clamp Terminal Block
110 mA typical
Spring Clamp Terminal Block
600 mA @ Maximum 5 VDC
600 mA @ Maximum 5 VDC
99 x 83 x 70
99 x 83 x 70
Connector Type
Internal Power Used (5 VDC loading)
Dimensions (H x W x D) in mm
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.87
RSTi
Industrial I/O
Discrete I/O Modules (Input)
RSTi discrete input modules are available for a wide range of applications requiring DC voltages
(5 VDC, 24 VDC, 48 VDC) and AC voltages (110 VAC, 220 VAC). The input modules are available in
4, 8 or 16 point density to optimize panel space.
Product Name
ST-1124
ST-1114
ST-1214
ST-1224
ST-1314
5 VDC Input,
4 points Negative Logic
5 VDC Input,
4 points Positive Logic
12/24 VDC Input,
4 points Positive Logic
12/24 VDC Input,
4 points Negative Logic
48 VDC Input,
4 points Positive Logic
Active
Active
Active
Active
Active
Discrete Input
Discrete Input
Discrete Input
Discrete Input
Discrete Input
5 VDC
(4.5 VDC to 5.5 VDC)
5 VDC
(4.5 VDC to 5.5 VDC)
24 VDC
(11 VDC to 28.8 VDC)
24 VDC
(10.2 VDC to 28.8 VDC)
48 VDC
(34 VDC to 60 VDC)
Number of Points
4
4
4
4
4
Points per Common
4
4
4
4
4
~1.3K ohms
~1.3K ohms
~5.1K ohms
~5.1K ohms
~12K ohms
3.0msec
Lifecycle Status
Module Type
Input Voltage Range
Input Impedance
Input Signal Delay
Filtering Time
Trigger Voltage
Maximum On State Current
Connector Type
Internal Power Used
(5 VDC loading)
Dimensions (H x W x D) in mm
3.88
< 0.5msec
< 0.5msec
3.0msec
3.0msec
Typical 1.5 msec.
(software filtering)
Typical 1.5 msec.
(software filtering)
Typical 1.5 msec.
Typical 1.5 msec.
On State: 2.4 VDC to
5.5 VDC
OFF State: 0.8 VDC
On State: 2.4 VDC to
5.5 VDC
OFF State: 0.8 VDC
ON State: 10.2 to
28.8 VDC
OFF State: 5 VDC
ON State: 10.2 to
28.8 VDC
OFF State: 5 VDC
ON State: 48 VDC
(34 VDC to 60 VDC)
OFF State: 10 VDC
4.5 mA per point
at 5.5 VDC
4.5 mA per point
at 5.5 VDC
6 mA per point
at 28.8 VDC
6 mA per point
at 28.8 VDC
4 mA per point
at 48 VDC
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
35 mA @ 5.0 VDC
Maximum
35 mA @ 5.0 VDC
Maximum
35 mA @ 5.0 VDC
Maximum
35 mA @ 5.0 VDC
Maximum
35 mA @ 5.0 VDC
Maximum
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Discrete I/O Modules (Input)
RSTi discrete input modules are available for a wide range of applications requiring DC voltages
(5 VDC, 24 VDC, 48 VDC) and AC voltages (110 VAC, 220 VAC). The input modules are available in
4, 8 or 16 point density to optimize panel space.
Product Name
ST-1324
ST-131F
ST-1218
ST-1228
ST-121F
48 VDC Input, 4 points
Negative Logic
48 VDC Input, 16 points
Positive Logic
12/24 VDC Input, 8
points Positive Logic
12/24 VDC Input, 8 points
Negative Logic
12/24 VDC Input,
16 points Positive Logic
Active
Active
Active
Active
Active
Discrete Input
Discrete Input
Discrete Input
Discrete Input
Discrete Input
48 VDC
(34 VDC to 60 VDC)
48 VDC
(34 VDC to 60 VDC)
24 VDC
(10.2 VDC to 28.8 VDC)
24 VDC
(10.2 VDC to 28.8 VDC)
24 VDC
(10.2 VDC to 28.8 VDC)
Number of Points
4
16
8
8
16
Points per Common
4
16
8
8
16
Input Impedance
~12K ohms
~12K ohms
~5.1K ohms
~5.1K ohms
~5.1K ohms
Input Signal Delay
3.0msec
Lifecycle Status
Module Type
Input Voltage Range
3.0msec
3.0msec
3.0msec
3.0msec
Typical 1.5 msec.
Typical 1.5 msec.
Typical 1.5 msec.
Typical 1.5 msec.
ON State: 48 VDC
(34 VDC to 60 VDC)
OFF State: 10 VDC
ON State: 48 VDC
(34 VDC to 60 VDC)
OFF State: 10 VDC
ON State: 10.2 to
28.8 VDC
OFF State: 5 VDC
ON State: 10.2 to
28.8 VDC
OFF State: 5 VDC
ON State: 10.2 to
28.8 VDC
OFF State: 5 VDC
Maximum On State Current
4 mA per point
at 48 VDC
2.5 mA per point
at 60 VDC
6 mA per point
at 28.8 VDC
6 mA per point
at 28.8 VDC
6 mA per point
at 28.8 VDC
Connector Type
Spring Clamp
Terminal Block
Connector Type Hirose,
HIF3BA-20D-2.54DSA
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Connector Type Hirose,
HIF3BA-20D-2.54DSA
35 mA @ 5.0 VDC
Maximum
45 mA @ 5.0 VDC
Maximum
35 mA @ 5.0 VDC
Maximum
35 mA @ 5.0 VDC
Maximum
45 mA @ 5.0 VDC
Maximum
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
Filtering Time
Trigger Voltage
Internal Power Used
(5 VDC loading)
Dimensions (H x W x D) in mm
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.89
RSTi
Industrial I/O
Discrete I/O Modules (Input)
RSTi discrete input modules are available for a wide range of applications requiring DC voltages
(5 VDC, 24 VDC, 48 VDC) and AC voltages (110 VAC, 220 VAC). The input modules are available in
4, 8 or 16 point density to optimize panel space.
Product Name
ST-122F
ST-1804
ST-1904
12/24 VDC Input,
16 points Negative Logic
110 VAC Input,
4 points (47 to 63Hz)
240 VAC Input,
4 points (47 to 63Hz)
Active
Active
Active
Discrete Input
Discrete Input
Discrete Input
24 VDC
(10.2 VDC to 28.8 VDC)
120 VAC
(85 VAC to 132 VAC)
240 VAC
(170 VAC to 264 VAC)
Number of Points
16
4
4
Points per Common
16
4
4
~5.1K ohms
~11K ohms
~22K ohms
3.0msec
10.0msec
10.0msec
ON State: 10.2 to
28.8 VDC
OFF State: 5 VDC
ON State: 85 VAC to
132 VAC
OFF State: 60 VAC
ON State: 170 VAC to
264 VAC
OFF State: 130 VAC
6 mA per point
at 28.8 VDC
8 mA per point
at 132 VAC
12 mA per point
at 264 VAC
Connector Type Hirose,
HIF3BA-20D-2.54DSA
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
45 mA @ 5.0 VDC
Maximum
35 mA @ 5.0 VDC
Maximum
35 mA @ 5.0 VDC
Maximum
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
Lifecycle Status
Module Type
Input Voltage Range
Input Impedance
Input Signal Delay
Filtering Time
Trigger Voltage
Maximum On State Current
Connector Type
Internal Power Used
(5 VDC loading)
Dimensions (H x W x D) in mm
3.90
Typical 1.5 msec.
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Analog I/O Modules (Input)
RSTi analog input modules are available in a wide range of voltage and current signals. Analog
input modules are available in 12 bit or 14 bit resolution.
Product Name
ST-3114
ST-3118
ST-3134
ST-3214
ST-3218
Analog 0 to 20 mA,
12bit Input, 4 channels
Analog 0 to 20 mA,
12bit Input, 8 channels
Analog 0 to 20 mA,
14bit Input, 4 channels
Analog 4 to 20 mA,
12bit Input, 4 channels
Analog 4 to 20 mA,
12bit Input, 8 channels
Active
Active
Active
Active
Active
Analog Input
Analog Input
Analog Input
Analog Input
Analog Input
0 to 20 mA Range
0 to 20 mA Range
0 to 20 mA Range
4 to 20 mA Range
4 to 20 mA Range
Number of Points
4
8
4
4
8
Points per Common
4
8
4
4
8
Update Rate
4msec/All channels
4msec/All channels
4msec/All channels
4msec/All channels
4msec/All channels
Resolution
12 bits:
4.88 microAmp/bit
12 bits:
4.88 microAmp/bit
14 bits:
1.22 microAmp/bit
12 bits:
3.9 microAmp/bit
12 bits:
3.9 microAmp/bit
Accuracy
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
Lifecycle Status
Module Type
Range
Open Wire if < 3 mA
Diagnostic Supported
Input Impedance
Internal Power Used
(5 VDC loading)
Connector Type
Dimensions (H x W x D) in mm
www.ge-ip.com
120 ohms
120 ohms
120 ohms
120 ohms
120 ohms
165 mA @ 5.0 VDC
Maximum
60 mA @ 5.0 VDC
Maximum
165 mA @ 5.0 VDC
Maximum
165 mA @ 5.0 VDC
Maximum
60 mA @ 5.0 VDC
Maximum
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
GE Intelligent Platforms Control Systems Solutions
3.91
RSTi
Industrial I/O
Analog I/O Modules (Input)
RSTi analog input modules are available in a wide range of voltage and current signals.
Analog input modules are available in 12 bit or 14 bit resolution.
ST-3234
ST-3274
ST-3424
ST-3428
ST-3444
Product Name
Analog 4 to 20 mA,
14bit Input, 4 channels
Analog 4 to 20 mA,
12bit Input, 4 channels
(connector type)
Analog 0 to 10 VDC,
12bit Input, 4 channels
Analog 0 to 10 VDC,
12bit Input, 8 channels
Analog 0 to 10 VDC,
14bit Input, 4 channels
Lifecycle Status
Active
Active
Active
Active
Active
Analog Input
Analog Input
Analog Input
Analog Input
Analog Input
4 to 20 mA Range
4 to 20 mA Range
0 to 10 VDC
0 to 10 VDC
0 to 10 VDC
Number of Points
4
4
4
8
4
Points per Common
4
4
4
8
4
Open Wire if < 3 mA
Open Wire if < 3 mA
Module Type
Range
Diagnostic Supported
Update Rate
Resolution
Accuracy
Input Impedance
Internal Power Used
(5 VDC loading)
Connector Type
Dimensions (H x W x D) in mm
3.92
4msec/All channels
4msec/All channels
4msec/All channels
4msec/All channels
4msec/All channels
14 bits: 0.9 microAmp/bit
12 bits: 3.9 microAmp/bit
12 bits: 2.44 mV/bit
12 bits: 2.44 mV/bit
14 bits: 0.6 mV/bit
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
120 ohms
120 ohms
500K ohms
500K ohms
500K ohms
165 mA @ 5.0 VDC
Maximum
165 mA @ 5.0 VDC
Maximum
165 mA @ 5.0 VDC
Maximum
60 mA @ 5.0 VDC
Maximum
170 mA @ 5.0 VDC
Maximum
Spring Clamp
Terminal Block
Requires Sensor Connect
3M Mini-Clamp Plug,
37104 Series
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Analog I/O Modules (Input)
RSTi analog input modules are available in a wide range of voltage and current signals.
Analog input modules are available in 12 bit or 14 bit resolution.
ST-3524
ST-3544
ST-3624
ST-3644
Product Name
Analog -10 to 10 VDC,
12bit Input, 4 channels
Analog -10 to 10 VDC,
14bit Input, 4 channels
Analog 0 to 5 VDC,
12bit Input, 4 channels
Analog 0 to 5 VDC,
14bit Input, 4 channels
Lifecycle Status
Active
Active
Active
Active
Module Type
Analog Input
Analog Input
Analog Input
Analog Input
Range
-10 to 10 VDC
-10 to 10 VDC
0 to 5 VDC
0 to 5 VDC
Number of Points
4
4
4
4
Points per Common
4
4
4
4
4msec/All channels
4msec/All channels
4msec/All channels
4msec/All channels
12 bits: 4.8 mV/bit
14 bits: 1.2 mV/bit
12 bits: 1.22 mV/bit
14 bits: 0.3 mV/bit
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
Diagnostic Supported
Update Rate
Resolution
Accuracy
Input Impedance
Internal Power Used
(5 VDC loading)
Connector Type
Dimensions (H x W x D) in mm
www.ge-ip.com
500K ohms
500K ohms
500K ohms
500K ohms
170 mA @ 5.0 VDC
Maximum
170 mA @ 5.0 VDC
Maximum
170 mA @ 5.0 VDC
Maximum
170 mA @ 5.0 VDC
Maximum
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
GE Intelligent Platforms Control Systems Solutions
3.93
RSTi
Industrial I/O
Discrete I/O Modules (Output)
RSTi discrete output modules are available for a wide range of applications requiring
DC voltages (5 VDC, 24 VDC, 48 VDC) and AC voltages (12 VAC, 125 VAC). The modules are
available in 4, 8 or 16 point density to optimize panel space. Relay output modules are also
available. The ST-2792 has an added feature of manual/automatic override.
ST-2114
ST-2124
ST-2314
ST-2324
Product Name
5 VDC/20 mA TTL Inverting
Output, 4 points
5 VDC, 4 Points,
TTL Non-Inverting Output
(Default: 0V)
4 points, 24 VDC Negative Logic,
Output 0.5 Amps
4 points, 24 VDC Positive Logic,
Output 0.5 Amps
Lifecycle Status
Active
Active
Active
Active
Digital Outputs
Digital Outputs
Digital Outputs
Digital Outputs
5 VDC nominal, Min. 4.5 VDC
to Max. 5.5 VDC
5 VDC nominal, Min. 4.5 VDC
to Max. 5.5 VDC
24 VDC nominal, Min. 11 VDC
to Max. 28.8 VDC
24 VDC nominal, Min. 11 VDC
to Max. 28.8 VDC
Number of Points
4
4
4
4
Points per Common
4
4
4
4
Output Short-Circuit protection
Field Power Over Voltage
Protection (about 6.7 VDC)
Field Power Reverse
Voltage Protection
Output Short-Circuit protection
Field Power Over Voltage
Protection (about 6.7 VDC)
Field Power Reverse
Voltage Protection
Over Temperature shut down:
Min. 150°C Over Current Limit :
Min. 3.5A/Max. 7A Per Channel
Short Circuit Protection
ESD Protection: 16.5Kv
Over Temperature shut down:
Min. 150°C Over Current Limit:
Min. 3.5A/Max.7.5A Per Channel
Short Circuit Protection
ESD Protection: 5.0Kv
Min. 4.8 VDC @ 5 VDC, 5 mA
Max. 0.3 VDC @ 0 VDC, 5 mA
Max. 20 mA Per Channel
Max. 80 mA All Common
Max. 20 mA Per Channel
Max. 80 mA All Common
Max. 0.5A Per Channel
Max. 2.0A All Common
Max. 0.5A Per Channel
Max. 2.0A All Common
40 mA For 10ms, Repeatable
Every 1 Sec.
40 mA For 10ms, Repeatable
Every 1 Sec.
OFF to ON: Max. 0.3ms
ON to OFF: Max. 0.3ms
OFF to ON: Max. 0.3ms
ON to OFF: Max. 0.3ms
OFF to ON : Max. 0.3ms
ON to OFF: Max. 0.3ms
OFF to ON: Max. 0.3ms
ON to OFF: Max. 0.3ms
Module Type
Output Range
Diagnostic Supported
Protection
ON Voltage/OFF Voltage
Load Current per Point
Output Inrush Current
Response Time (ms)
Polarity
TTL Inverting
TTL Non-Inverting
Negative Logic
Positive Logic
5 VDC (4.5 VDC to 5.5 VDC)
5 VDC (4.5 VDC to 5.5 VDC)
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
5 mA @ 28.8 VDC Per Channel
5 mA @ 28.8 VDC Per Channel
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
50 mA @ 5.0 VDC
Maximum
50 mA @ 5.0 VDC
Maximum
45 mA @ 5.0 VDC
Maximum
45 mA @ 5.0 VDC
Maximum
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
Field Power Requirement
Power Dissipation
Connector Type
Internal Power Used
(5 VDC loading)
Dimensions (H x W x D) in mm
3.94
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Discrete I/O Modules (Output)
RSTi discrete output modules are available for a wide range of applications requiring
DC voltages (5 VDC, 24 VDC, 48 VDC) and AC voltages (12 VAC, 125 VAC). The modules are
available in 4, 8 or 16 point density to optimize panel space. Relay output modules are also
available. The ST-2792 has an added feature of manual/automatic override.
ST-2414
Product Name
4 points, 24 VDC Negative
Logic, Output 0.5 Amps with
Diagnostics
ST-2424
ST-2514
4 points, 24 VDC Positive Logic, 4 points, 24 VDC Negative Logic,
Output 0.5 Amps with
Output 2 Amps with
Diagnostics
Diagnostics
ST-2524
4 points, 24 VDC Positive Logic,
Output 2 Amps with
Diagnostics
Active
Active
Active
Active
Digital Outputs
Digital Outputs
Digital Outputs
Digital Outputs
24 VDC nominal, Min. 11 VDC
to Max. 28.8 VDC
24 VDC nominal, Min. 11 VDC
to Max. 28.8 VDC
24 VDC nominal, Min. 11 VDC
to Max. 28.8 VDC
24 VDC nominal, Min. 11 VDC
to Max. 28.8 VDC
Number of Points
4
4
4
4
Points per Common
4
4
4
4
Point Fault Reported to
Network Interface
Point Fault Reported to
Network Interface
Point Fault Reported to
Network Interface
Point Fault Reported to
Network Interface
Over Temperature shut down:
Min. 150°C Over Current Limit:
Min. 3.5A/Max. 7A Per Channel
Short Circuit Protection
ESD Protection: 16.5Kv
Over Temperature shut down:
Min. 150°C Over Current Limit:
Min. 3.5A/Max.7.5A Per Channel
Short Circuit Protection
ESD Protection: 5.0Kv
Over Temperature shut down:
Min. 150°C Over Current Limit:
Min. 3.5A/Max. 7A Per Channel
Short Circuit Protection
ESD Protection: 16.5Kv
Over Temperature shut down:
Min. 150°C Over Current Limit:
Min. 6A/Max. 15A Per Channel
Short Circuit Protection
ESD Protection: 5.0Kv
Max. 0.5A Per Channel
Max. 2.0A All Common
Max. 0.5A Per Channel
Max. 2.0A All Common
Max. 2A Per Channel
Max. 8A All Common
Max. 2A Per Channel
Max. 8A All Common
OFF to ON: Max. 0.3ms
ON to OFF: Max. 0.3ms
OFF to ON: Max. 0.3ms
ON to OFF: Max. 0.3ms
OFF to ON: Max. 0.3ms
ON to OFF: Max. 0.3ms
OFF to ON : Max. 0.3ms
ON to OFF: Max. 0.3ms
Lifecycle Status
Module Type
Output Range
Diagnostic Supported
Protection
ON Voltage/OFF Voltage
Load Current per Point
Output Inrush Current
Response Time (ms)
Polarity
Negative Logic
Positive Logic
Negative Logic
Positive Logic
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
5 mA @ 28.8 VDC Per Channel
5 mA @ 28.8 VDC Per Channel
5 mA @ 28.8 VDC Per Channel
5 mA @ 28.8 VDC Per Channel
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
45 mA @ 5.0 VDC
Maximum
45 mA @ 5.0 VDC
Maximum
45 mA @ 5.0 VDC
Maximum
45 mA @ 5.0 VDC
Maximum
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
Field Power Requirement
Power Dissipation
Connector Type
Internal Power Used
(5 VDC loading)
Dimensions (H x W x D) in mm
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.95
RSTi
Industrial I/O
Discrete I/O Modules (Output)
RSTi discrete output modules are available for a wide range of applications requiring
DC voltages (5 VDC, 24 VDC, 48 VDC) and AC voltages (12 VAC, 125 VAC). The modules are
available in 4, 8 or 16 point density to optimize panel space. Relay output modules are also
available. The ST-2792 has an added feature of manual/automatic override.
ST-2614
Product Name
ST-2624
ST-2318
4 points, 24 VDC Negative Logic, 4 points, 24 VDC Positive Logic, 8 points, 24 VDC Negative Logic,
Output 2 Amps
Output 2 Amps
Output 0.5 Amps
ST-2328
8 points, 24 VDC Positive Logic,
Output 0.5 Amps
Target Release August 2012
Target Release August 2012
Active
Active
Digital Outputs
Digital Outputs
Digital Outputs
Digital Outputs
24 VDC nominal, Min. 11 VDC
to Max. 28.8 VDC
24 VDC nominal, Min. 11 VDC
to Max. 28.8 VDC
24 VDC nominal, Min. 11 VDC
to Max. 28.8 VDC
24 VDC nominal, Min. 11 VDC
to Max. 28.8 VDC
Number of Points
4
4
8
8
Points per Common
4
4
8
8
Over Temperature shut down:
Min. 150°C Over Current Limit:
Min. 3.5A/Max. 7A Per Channel
Short Circuit Protection ESD
Protection: 16.5Kv
Over Temperature shut down:
Min. 150°C Over Current Limit:
Min. 6A/Max. 15A Per Channel
Short Circuit Protection ESD
Protection: 5.0Kv
Over Temperature shut down:
Min. 150°C Over Current Limit:
Min. 3.5A/Max. 7A Per Channel
Short Circuit Protection ESD
Protection: 16.5Kv
Over Temperature shut down:
Min. 150°C Over Current Limit:
Min. 3.5A/Max. 7A Per Channel
Short Circuit Protection ESD
Protection : 16.5Kv
Max. 2A Per Channel Max.
8A All Common
Max. 2A Per Channel
Max. 8A All Common
Max. 0.5A Per Channel
Max. 2.0A All Common
Max. 0.5A Per Channel
Max. 2.0A All Common
OFF to ON: Max. 0.3ms
ON to OFF: Max. 0.3ms
OFF to ON: Max. 0.3ms
ON to OFF: Max. 0.3ms
OFF to ON: Max. 0.3ms
ON to OFF: Max. 0.3ms
OFF to ON: Max. 0.3ms
ON to OFF: Max. 0.3ms
Lifecycle Status
Module Type
Output Range
Diagnostic Supported
Protection
ON Voltage/OFF Voltage
Load Current per Point
Output Inrush Current
Response Time (ms)
Polarity
Negative Logic
Positive Logic
Negative Logic
Positive Logic
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
5 mA @ 28.8 VDC Per Channel
5 mA @ 28.8 VDC Per Channel
5 mA @ 28.8 VDC Per Channel
5 mA @ 28.8 VDC Per Channel
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Spring Clamp Terminal Block
45 mA @ 5.0 VDC Maximum
45 mA @ 5.0 VDC Maximum
60 mA @ 5.0 VDC Maximum
45 mA @ 5.0 VDC Maximum
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
Field Power Requirement
Power Dissipation
Connector Type
Internal Power Used
(5 VDC loading)
Dimensions (H x W x D) in mm
3.96
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Discrete I/O Modules (Output)
RSTi discrete output modules are available for a wide range of applications requiring
DC voltages (5 VDC, 24 VDC, 48 VDC) and AC voltages (12 VAC, 125 VAC). The modules are
available in 4, 8 or 16 point density to optimize panel space. Relay output modules are also
available. The ST-2792 has an added feature of manual/automatic override.
Product Name
ST-221F
ST-222F
ST-2742
ST-2744
16 points, 24 VDC Negative
Logic, Output 0.5 Amps
(Connector Style)
16 points, 24 VDC Positive Logic,
Output 0.5 Amps
(Connector Style)
2 points, Relay Output,
2 Amps
4 points, Relay Output,
2 Amps
Active
Active
Active
Active
Digital Outputs
Digital Outputs
Digital Outputs
Digital Outputs
24 VDC nominal, Min. 11 VDC
to Max. 28.8 VDC
24 VDC nominal, Min. 11 VDC
to Max. 28.8 VDC
5~28.8 VDC @ 2.0A Resistive 48
VDC @ 0.8A Resistive
110 VDC @ 0.5A Resistive
250 VAC @ 2.0A Resistive
5~28.8 VDC @ 2.0A Resistive 48
VDC @ 0.8A Resistive
110 VDC @ 0.5A Resistive
250 VAC @ 2.0A Resistive
Number of Points
16
16
2
4
Points per Common
16
16
1
4
Over Temperature shut down:
Min. 150°C Over Current Limit:
Min. 3.5A/Max. 7A Per Channel
Short Circuit Protection
ESD Protection : 16.5Kv
Over Temperature shut down:
Min. 150°C Over Current Limit:
Min. 3.5A/Max. 7A Per Channel
Short Circuit Protection
ESD Protection: 16.5Kv
Max. 0.5A Per Channel
Max. 4.0A All Common
Max. 0.5A Per Channel
Max. 4.0A All Common
2A @ 5~28.8 VDC
0.8A @ 48 VDC
0.5A @ 110 VDC
2A @ 250 VAC
2A @ 5~28.8 VDC
0.8A @ 48 VDC
0.5A @ 110 VDC
2A @ 250 VAC
OFF to ON: Max. 0.3ms
ON to OFF: Max. 0.3ms
OFF to ON: Max. 0.3ms
ON to OFF: Max. 0.3ms
OFF to ON : Max. 10ms
ON to OFF: Max. 10ms
OFF to ON: Max. 10ms
ON to OFF: Max. 10ms
24 VDC, 240 VAC
No Connection with Field Power
Field Power passes though to the
next module
Lifecycle Status
Module Type
Output Range
Diagnostic Supported
Protection
ON Voltage/OFF Voltage
Load Current per Point
Output Inrush Current
Response Time (ms)
Polarity
Negative Logic
Positive Logic
24 VDC (11 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
3 mA @ 28.8 VDC Per Channel
3 mA @ 28.8 VDC Per Channel
Connector Type Hirose,
HIF3BA-20D-2.54DSA
Connector Type Hirose,
HIF3BA-20D-2.54DSA
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
80 mA @ 5.0 VDC
Maximum
80 mA @ 5.0 VDC
Maximum
65 mA @ 5.0 VDC
Maximum
130 mA @ 5.0 VDC
Maximum
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
Field Power Requirement
Power Dissipation
Connector Type
Internal Power Used
(5 VDC loading)
Dimensions (H x W x D) in mm
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
3.97
RSTi
Industrial I/O
Discrete I/O Modules (Output)
RSTi discrete output modules are available for a wide range of applications requiring
DC voltages (5 VDC, 24 VDC, 48 VDC) and AC voltages (12 VAC, 125 VAC). The modules are
available in 4, 8 or 16 point density to optimize panel space. Relay output modules are also
available. The ST-2792 has an added feature of manual/automatic override.
ST-2748
ST-2792
ST-2852
8 points, Relay Output, 2 Amps
2 points, Relay Output, 2 Amps
(Manual Override or Automatic Operation)
2 points, 12 to 125 VAC Output, 0.5 Amps
Product Name
Active
Target Release August 2012
Active
Module Type
Digital Outputs
Digital Outputs
Digital Outputs
5~28.8 VDC @ 2.0A Resistive
48 VDC @ 0.8A Resistive
110 VDC @ 0.5A Resistive
250 VAC @ 2.0A Resistive
15~132 VAC 47 to 63Hz
Output Range
5~28.8 VDC @ 2.0A Resistive
48 VDC @ 0.8A Resistive
110 VDC @ 0.5A Resistive
250 VAC @ 2.0A Resistive
Number of Points
8
2
2
Points per Common
8
2
2
2A @ 5~28.8 VDC
0.8A @ 48 VDC
0.5A @ 110 VDC
2A @ 250 VAC
2A @ 5~28.8 VDC
0.8A @ 48 VDC
0.5A @ 110 VDC
2A @ 250 VAC
0.5 Amp
Lifecycle Status
Diagnostic Supported
Protection
ON Voltage/OFF Voltage
Load Current per Point
40 Amp for 16 mSec. or 4 Amp for 30 Sec.
Output Inrush Current
Response Time (ms)
OFF to ON: Max. 10ms
ON to OFF: Max. 10ms
OFF to ON: Max. 10ms
ON to OFF: Max. 10ms
OFF to ON: Max. 3ms
ON to OFF: Max. 1/2 Cycle plus 3ms
No Connection with Field Power
Field Power passes though to the
next module
No Connection with Field Power
Field Power passes though to the
next module
120 VAC nominal Voltage Range: 12~125 VAC
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
150 mA @ 5.0 VDC
Maximum
70 mA @ 5.0 VDC
Maximum
35 mA @ 5.0 VDC
Maximum
99 x 24 x 70
99 x 12 x 70
99 x 12 x 70
Polarity
Field Power Requirement
Power Dissipation
Connector Type
Internal Power Used
(5 VDC loading)
Dimensions (H x W x D) in mm
3.98
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Analog I/O Modules (Output)
RSTi analog output modules are available in a wide range of voltage and current signals.
Specialty analog modules are also available for manual over-ride and 0 to 1 Amp analog out.
Product Name
ST-4112
ST-4114
ST-4212
ST-4214
2 channels Current Output,
0 to 20 mA, 12bit
4 channels Current Output,
0 to 20 mA, 12bit
2 channels Current Output,
4 to 20 mA, 12bit
4 channels Current Output,
4 to 20 mA, 12bit
Active
Active
Active
Active
Module Type
Analog Output
Analog Output
Analog Output
Analog Output
Output Range
Lifecycle Status
0 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
Number of Points
2
4
2
4
Points per Common
2
4
2
4
Resolution
Accuracy
Update Rate
Maximum Output Load
Connector Type
Internal Power Used
(5 VDC loading)
Dimensions (H x W x D) in mm
www.ge-ip.com
12 bits : 4.88uA/Bit
12 bits : 4.88uA/Bit
12 bits : 3.9uA/Bit
12 bits : 3.9uA/Bit
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
(100uA~20 mA) ±0.25%
Full Scale @ 25°C(0uA~100uA)
±0.3% Full Scale @ 0°C, 60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
2msec for all channels
4msec for all channels
2msec for all channels
4msec for all channels
Max. 500Ω
Max. 500Ω
Max. 500Ω
Max. 500Ω
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
60 mA @ 5.0 VDC
Maximum
60 mA @ 5.0 VDC
Maximum
60 mA @ 5.0 VDC
Maximum
60 mA @ 5.0 VDC
Maximum
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
GE Intelligent Platforms Control Systems Solutions
3.99
RSTi
Industrial I/O
Analog I/O Modules (Output)
RSTi analog output modules are available in a wide range of voltage and current signals.
Specialty analog modules are also available for manual over-ride and 0 to 1 Amp analog out.
ST-4274
ST-4422
ST-4424
ST-4474
4 channels Current Output,
4 to 20 mA, 12bit
(Connector Style)
2 channels Voltage Output,
0 to 10 VDC, 12bit
4 channels Voltage Output,
0 to 10 VDC, 12bit
4 channels Current Output,
0 to 10 VDC, 12bit
(Connector Style)
Active
Active
Active
Active
Module Type
Analog Output
Analog Output
Analog Output
Analog Output
Output Range
Product Name
Lifecycle Status
4 to 20 mA
0 to 10 VDC
0 to 10 VDC
0 to 10 VDC
Number of Points
4
2
4
4
Points per Common
4
2
4
4
Resolution
Accuracy
Update Rate
Maximum Output Load
Connector Type
Internal Power Used
(5 VDC loading)
Dimensions (H x W x D) in mm
3.100
12 bits : 3.91uA/Bit
12 bits : 2.44mV/Bit
12 bits : 2.44mV/Bit
12 bits : 2.44mV/Bit
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
1.2msec for all channels
2msec for all channels
4msec for all channels
1.2msec for all channels
Max. 500Ω
Min. 5kΩ
Min. 2kΩ
Min. 2kΩ
Requires Sensor Connect 3M
Mini-Clamp Plug, 37104 Series
AWG#20~22 available
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Requires Sensor Connect 3M
Mini-Clamp Plug, 37104 Series
AWG#20~22 available
40 mA @ 5.0 VDC
Maximum
155 mA @ 5.0 VDC
Maximum
60 mA @ 5.0 VDC
Maximum
60 mA @ 5.0 VDC
Maximum
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Analog I/O Modules (Output)
RSTi analog output modules are available in a wide range of voltage and current signals.
Specialty analog modules are also available for manual over-ride and 0 to 1 Amp analog out.
ST-4491
ST-4522
ST-4622
ST-4911
Product Name
1 channels Voltage Output,
0 to 10 VDC, 12bit.
(Manual Override or
Automatic Operation)
2 channels Voltage Output,
-10 to +10 VDC, 12bit
2 channels Voltage Output,
0 to 5 VDC, 12bit
1 channels Voltage Output,
0 to 1 Amp, 12bit.
Lifecycle Status
Active
Active
Active
Active
Module Type
Analog Output
Analog Output
Analog Output
Analog Output
Output Range
0 to 10 VDC
-10 to +10 VDC
0 to 5 VDC
0 to 1 Amp
1
2
2
1
Number of Points
Points per Common
Resolution
Accuracy
Update Rate
Maximum Output Load
Connector Type
Internal Power Used
(5 VDC loading)
Dimensions (H x W x D) in mm
www.ge-ip.com
1
2
2
1
12 bits : 2.44mV/Bit
12 bits : 4.88mV/Bit
12 bits : 1.22mV/Bit
12 bits : 2.44 mA/Bit
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
1.2msec for all channels
2msec for all channels
2msec for all channels
1msec for all channels
Min. 2kΩ
Min. 5kΩ
Min. 5kΩ
13Ω, ±5%
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
Spring Clamp
Terminal Block
60 mA @ 5.0 VDC
Maximum
155 mA @ 5.0 VDC
Maximum
155 mA @ 5.0 VDC
Maximum
60 mA @ 5.0 VDC
Maximum
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
GE Intelligent Platforms Control Systems Solutions 3.101
RSTi
Industrial I/O
RTD Modules
RSTi RTD input modules 2 and 3 wire sensors. The modules also support diagnostics.
RTD Input Types
• PT100, PT200, PT500, PT1000, PT50
• JPT100, JPT200, JPT500, JPT1000, JPT50
• NI100, NI200, NI500, NI000
• NI120, NI1000LG
• CU10
Resistance Input
• 100mΩ/bit, 10mΩ/bit, 20mΩ/bit, 50mΩ/bit
Product Name
ST-3702
ST-3704
ST-3708
2 Channels, RTD Input
(2 and 3 Wire)
4 Channels, RTD Input
(3 Wire) Connector Style
8 Channels, RTD Input
(3 Wire) Connector Style
Active
Active
Active
Temperature Sensing
Temperature Sensing
Temperature Sensing
PT50, PT100, PT200, PT500, PT1000,
JPT100, JPT200, JPT500, JPT1000, NI100,
Nl200, NI500, NI1000, NI120, CU10,
Resistance 100mΩ/Bit,
Resistance 10mΩ/Bit,
Resistance 20mΩ/Bit
PT100, PT200, PT500, PT1000, PT50
JPT100, JPT200, JPT500,
JPT1000, JPT50
NI100, NI200, NI500, NI000
NI120, NI1000LG
Resistance Input
100mΩ/bit, 10mΩ/bit, 20mΩ/bit,
50mΩ/bit
PT100, PT200, PT500, PT1000, PT50
JPT100, JPT200, JPT500,
JPT1000, JPT50
NI100, NI200, NI500,NI1000
NI120, NI1000LG
Resistance Input
100mΩ/bit, 10mΩ/bit, 20mΩ/bit,
50mΩ/bit
Number of Points
2
4
8
Points per Common
2
4
8
Open Channel
Open Channel
Over Range
Open Channel
Over Range
Resolution
0.1°C / 10mΩ
±0.1°C/ F, 10mΩ
±0.1°C/ F, 10mΩ
Accuracy
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.3% Full Scale @ 25°C
±0.5% Full Scale @ 0°C,
60°C
±0.3% Full Scale @ 25°C
±0.5% Full Scale @ 0°C,
60°C
Update Rate
200msec for all channels
30msec per channel
30msec per channel
70 mA @ 5.0 VDC Maximum
100 mA @ 5.0 VDC Maximum
100 mA @ 5.0 VDC Maximum
Spring Clamp
Terminal Block
Requires connector type Hirose,
HIF3BA-20D-2.54C
Requires connector type Hirose,
HIF3BA-20D-2.54C
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
Lifecycle Status
Module Type
Range
Diagnostic Supported
Internal Power Used (5 VDC loading)
Connector Type
Dimensions (H x W x D) in mm
3.102
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Thermocouple Modules
RSTi Thermocouple/mV input modules support a wide range of thermocouple sensors. The
modules also support diagnostics and Cold Junction Compensation.
Thermocouple Inputs
• Type K/J/T/B/R/S/E/N/L/U/C/D
mV Input
• 10uV/bit, 1uV/bit, 2uV/bit
Product Name
Lifecycle Status
Module Type
Range
Number of Points
Points per Common
Diagnostic Supported
ST-3802
ST-3804
ST-3808
2 Channels, Thermocouple Input/mV
4 Channels, Thermocouple
Input/mV (External CJC support)
8 Channels, Thermocouple
Input/mV (External CJC support)
Active
Active
Active
Temperature Sensing
Temperature Sensing
Temperature Sensing
Type K/J/T/B/R/S/E/N/L/U/C/D
mV Input
10uV/Bit, 1uV/Bit, 2uV/Bit
Type K/J/T/B/R/S/E/N/L/U/C/D
mV Input
10uV/bit, 1uV/bit, 2uV/bit
Type K/J/T/B/R/S/E/N/L/U/C/D
mV Input
10uV/bit, 1uV/bit, 2uV/bit
2
4
8
2
4
8
Open Channel
Open Channel
Over Range
Open Channel
Over Range
Resolution
0.1°C / 10mΩ
0.1°C / °F , 10uV
±0.1°C / F, 1uV
Accuracy
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
±0.1% Full Scale @ 25°C
±0.3% Full Scale @ 0°C,
60°C
Update Rate
200msec for all channels
30msec per channel
30msec per channel
Internal Power Used (5 VDC loading)
Connector Type
Dimensions (H x W x D) in mm
www.ge-ip.com
70 mA @ 5.0 VDC Maximum
120 mA @ 5.0 VDC Maximum
140 mA @ 5.0 VDC Maximum
Spring Clamp
Terminal Block
Requires connector type Hirose,
HIF3BA-20D-2.54C
Requires connector type Hirose,
HIF3BA-20D-2.54C
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
GE Intelligent Platforms Control Systems Solutions 3.103
RSTi
Industrial I/O
Serial Communications Modules
RSTi serial communications modules enable serial devices, such as bar code readers, scales
and printers, to connect to the network interface.
Product Name
Lifecycle Status
Module Type
Protocol Supported
Interface Connector Type
Baud Rate
I/O Data Size
Internal Power Used (5 VDC loading)
Dimensions (H x W x D) in mm
3.104
ST-5211
ST-5212
ST-5221
ST-5231
1 Channel Serial RS-232
2 Channel Serial RS-232
1 Channel Serial RS-422
1 Channel Serial RS-485
Active
Active
Active
Active
Serial Communications
Serial Communications
Serial Communications
Serial Communications
ASCII, TxD, RxD, Full Duplex
ASCII, TxD, RxD, Full Duplex
ASCII, TxD, RxD, Full Duplex
ASCII, TxD, RxD, Full Duplex
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Spring Clamp Terminal Block
300 to 115,200 bps
300 to 115,200 bps
300 to 115,200 bps
300 to 115,200 bps
6 Bytes In/6 Bytes Out
Buffer: RxD 1024 Bytes;
TxD 256 Bytes
12 Bytes In/12 Bytes Out
Buffer: RxD 1024 Bytes;
TxD 256 Bytes
6 Bytes In/6 Bytes Out
Buffer: RxD 1024 Bytes;
TxD 256 Bytes
6 Bytes In/6 Bytes Out
Buffer: RxD 1024 Bytes;
TxD 256 Bytes
95 mA @ 5.0 VDC Maximum
110 mA @ 5.0 VDC Maximum
155 mA @ 5.0 VDC Maximum
110 mA @ 5.0 VDC Maximum
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Serial Communications Modules
RSTi serial communications modules enable serial devices, such as bar code readers, scales
and printers, to connect to the network interface.
Product Name
Lifecycle Status
Module Type
Protocol Supported
Interface Connector Type
Baud Rate
I/O Data Size
Internal Power Used (5 VDC loading)
Dimensions (H x W x D) in mm
www.ge-ip.com
ST-5232
ST-5252
ST-5272
2 Channel Serial RS-485
2 Channel Serial RS-232
(Expanded Data Size)
2 Channel Serial RS-485
(Expanded Data Size)
Active
Target Release July 2012
Target Release July 2012
Serial Communications
Serial Communications
Serial Communications
ASCII, TxD, RxD, Full Duplex
ASCII, TxD, RxD, Full Duplex
ASCII, TxD, RxD, Full Duplex
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Spring Clamp Terminal Block
300 to 115,200 bps
1200 to 115,200 bps
1200 to 115,200 bps
12 Bytes In/12 Bytes Out
Buffer: RxD 1024 Bytes;
TxD 256 Bytes
38 Bytes In/38 Bytes Out
Buffer: RxD 256 Bytes;
TxD 256 Bytes
38 Bytes In/38 Bytes Out
Buffer: RxD 256 Bytes;
TxD 256 Bytes
155 mA @ 5.0 VDC Maximum
110 mA @ 5.0 VDC Maximum
155 mA @ 5.0 VDC Maximum
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
GE Intelligent Platforms Control Systems Solutions 3.105
RSTi
Industrial I/O
High Speed Counting
RSTi High Speed Counter modules interface to encoders and high speed pulse input devices.
The RSTi offers a wide range of counting functions and control. SSI interface is also supported
by the RSTi.
ST-5101
ST-5111
ST-5112
Product Name
1 Channel High Speed Counter,
5 VDC Input and 1 Output
1 Channel High Speed Counter,
24 VDC Input and 1 Output
2 Channel High Speed Counter,
24 VDC Inputs and 2 Outputs
Lifecycle Status
Active
Active
Active
High Speed Counter
High Speed Counter
High Speed Counter
Module Type
1-Input Mode - Up, Down 2-Input
Mode - Up/Inhibit, Up/Reset, Down/
Inhibit, Down/Reset, Up/Down,
Clock/Direction Encoder 1x,
Encoder 2x, Encoder 4x
Counter Operation
Count Rate
1.5Mhz
1.5Mhz
32 bit wide/channel
Counter Range
Input/Output Type
(1) 5 VDC Input / (1) 24 VDC
(5 to 28.8 VDC) Output
(1) 24 VDC Input / (1) 24 VDC
(5 to 28.8 VDC) Output
Protection
Off State Leakage Current
0~100KHz except Encoder 4x
0~50KHz, Encoder 4x
(2) 24 VDC Input / (2) 24 VDC
Output 0.5 Amp
Short Protection
Max. 0.5 mA
Max. 0.5 mA
Input Filters (Selectable)
Bypass / 1usec / 5usec / 10usec /
50usec / 100usec / 500usec / 1msec /
5msec / 10msec
Bypass / 1usec / 5usec / 10usec /
50usec / 100usec / 500usec / 1msec /
5msec / 10msec
Selectable On/Off Output Presets
Force OFF/ON Greater Than
Less Than Equal Overflow/Underflow
PWM Output
Force OFF/ON Greater Than
Less Than Equal Overflow/Underflow
PWM Output
Connector Type
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Internal Power Used (5 VDC loading)
80 mA @ 5.0 VDC Maximum
80 mA @ 5.0 VDC Maximum
160 mA @ 5.0 VDC Maximum
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
Dimensions (H x W x D) in mm
3.106
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
High Speed Counting
RSTi High Speed Counter modules interface to encoders and high speed pulse input devices.
The RSTi offers a wide range of counting functions and control. SSI interface is also supported
by the RSTi.
ST-5114
ST-5351
Product Name
4 Channel High Speed Counter,
24 VDC Inputs and 2 Outputs
1 Channel SSI Interface.
Gray Code or Natural Binary
Lifecycle Status
Active
Active
High Speed Counter
High Speed Counter
Module Type
Counter Operation
Count Rate
Counter Range
Input/Output Type
Protection
1-Input Mode - Up, Down 2-Input
Mode - Up/Inhibit, Up/Reset,
Down/Inhibit, Down/Reset, Up/Down,
Clock/Direction Encoder 1x,
Encoder 2x, Encoder 4x
0~50KHz except Encoder 4x
0~25KHz, Encoder 4x
62.5K, 100K, 125K, 250K,
500K, 1M, 2Mbps
32 bit wide/channel
Max. 30 bit
(4) 24 VDC Input / (2) 24 VDC
Output 0.5 Amp
D+, D- RS422 Differential Input C+,
C- RS422 Differential Output
Short Protection
Off State Leakage Current
Input Filters (Selectable)
Selectable On/Off Output Presets
Connector Type
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Internal Power Used (5VDC loading)
160 mA @ 5.0 VDC Maximum
150 mA @ 5.0 VDC Maximum
99 x 12 x 70
99 x 12 x 70
Dimensions (H x W x D) in mm
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 3.107
RSTi
Industrial I/O
Motion Control
RSTi motion options include Pulse Width Modulation and Pulse Train outputs for simple motion
applications. A wide range of control amplifiers is supported with the RSTi motion modules.
ST-5422
ST-5442
ST-5444
Product Name
2 Channels PWM Output,
1.5A/24 VDC, Source
2 Channels PWM Output,
0.5A/24 VDC, Source
4 Channels PWM Output,
0.5A/24 VDC, Source
Lifecycle Status
Active
Active
Active
Motion Control
Motion Control
Motion Control
PWM
PWM
PWM
2
2
4
Short Protection
Short Protection
Short Protection
No
No
No
Load Current per Point
1.5 Amp/Ch, 3 Amp/All Channel,
short protection
0.5 Amp/Ch, 1 Amp/All Channel,
short protection
0.5 Amp/Ch, 2 Amp/All Channel,
short protection
Output Inrush Current
Max. 2 A, 100ms/Channel
Max. 1.5 A, 100ms/Channel
Max. 1.5 A, 100ms/Channel
1~2500Hz±0.5%
1~2500Hz±0.5%
1~2500Hz±0.5%
0.0~100.0%±1.0(0.1%/1LSB), Ton>5us,
Toff>5us
0.0~100.0%±1.0(0.1%/1LSB), Ton>5us,
Toff>5us
0.0~100.0%±1.0(0.1%/1LSB), Ton>5us,
Toff>5us
Field Power Requirement
24 VDC (18 VDC to 28.8 VDC)
24 VDC (18 VDC to 28.8 VDC)
24 VDC (18 VDC to 28.8 VDC)
Connector Type
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Internal Power Used (5 VDC loading)
150 mA @ 5.0 VDC Maximum
150 mA @ 5.0 VDC Maximum
150 mA @ 5.0 VDC Maximum
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
Module Type
Drive Type
Number of Axes
Diagnostic Supported
Encoder Support
Frequency
Duty
Dimensions (H x W x D) in mm
3.108
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Motion Control
RSTi motion options include Pulse Width Modulation and Pulse Train outputs for simple motion
applications. A wide range of control amplifiers is supported with the RSTi motion modules.
ST-5641
ST-5642
ST-5651
Product Name
1 Channel Pulse and Direction Output,
0.5 A/24 VDC, Source
2 Channel Pulse and Direction Output,
0.5 A/24 VDC, Source
1 Channel Pulse and Direction Output,
RS-422
Lifecycle Status
Active
Active
Active
Motion Control
Motion Control
Motion Control
Pulse Output
Pulse Output
Pulse Output
1
2
1
Short Protection
Short Protection
No
No
No
0.5 Amp/Ch, 1 Amp/All Channel,
short protection
0.5 Amp/Ch, 2 Amp/All Channel,
short protection
Max. 10 Amps
1~20,000Hz±0.5% Continuous
Pulse Output Max. +1~+32767:
Pulse Direction Output OFF
Max. -1~-32767: Pulse Direction
Output ON.
1~20,000Hz±0.5% Continuous
Pulse Output Max. +1~+32767:
Pulse Direction Output OFF
Max. -1~-32767: Pulse Direction
Output ON.
5~20,000Hz±1.0% Continuous
Pulse Output Max. +1~+32767:
Pulse Direction Output OFF
Max. -1~-32767: Pulse Direction
Output ON.
50%±3.0% Fixed, Ton>5us, Toff>5us
50%±3.0% Fixed, Ton>5us, Toff>5us
50%±0.1% Fixed,Ton>10ns, Toff>10ns
24 VDC (18 VDC to 28.8 VDC)
24 VDC (18 VDC to 28.8 VDC)
24 VDC (11 VDC to 28.8 VDC)
Module Type
Drive Type
Number of Axes
Diagnostic Supported
Encoder Support
Load Current per Point
Output Inrush Current
Frequency
Duty
Field Power Requirement
Connector Type
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Internal Power Used (5 VDC loading)
150 mA @ 5.0 VDC Maximum
150 mA @ 5.0 VDC Maximum
150 mA @ 5.0 VDC Maximum
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
Dimensions (H x W x D) in mm
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 3.109
RSTi
Industrial I/O
Power Modules
The RSTi provides various power modules to reduce wiring and simplify installation. Modules that
support Smart Module ID will require one of the addresses on the bus.
The ST-7241 and ST-7641 enable multiple voltages to be supported on the RSTi bus such as 120
VAC. All modules to the right of the module will be based on the supply voltage of the ST-7x41.
The ST-7111 and ST-7511 boost the 5 VDC on the backplane bus when module power
requirement is exceeded. The ST-7x11 supplies 1.0 Amps of 5 VDC to the modules to the right
of the ST-7x11.
ST-7008
ST-7408
ST-7108
ST-7508
Product Name
Shield Signal Module,
8 channels
Shield Signal Smart Module,
8 channels
Common for 0 Volts Module,
8 channels
Common for 0 Volts Smart
Module, 8 channels
Lifecycle Status
Active
Active
Active
Active
Power Modules
Power Modules
Power Modules
Power Modules
No
Yes
No
Yes
Module Type
Smart Module (Uses Module ID)
Max. 10 Amps
Max. 10 Amps
Max. 10 Amps
Max. 10 Amps
LEDs
No
1 Green/Red LED, Module Status
No
1 Green/Red LED, Module Status
Diagnostic Supported
No
No
No
No
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Spring Clamp Terminal Block
None
Max. 18 mA @ 5 VDC
None
Max. 18 mA @ 5 VDC
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
Load Current per Point
Connector Type
Internal Power Used (5 VDC loading)
Dimensions (H x W x D) in mm
3.110
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Power Modules
The RSTi provides various power modules to reduce wiring and simplify installation. Modules that
support Smart Module ID will require one of the addresses on the bus.
The ST-7241 and ST-7641 enable multiple voltages to be supported on the RSTi bus such as 120
VAC. All modules to the right of the module will be based on the supply voltage of the ST-7x41.
The ST-7111 and ST-7511 boost the 5 VDC on the backplane bus when module power
requirement is exceeded. The ST-7x11 supplies 1.0 Amps of 5 VDC to the modules to the right
of the ST-7x11.
ST-7118
ST-7518
ST-7188
ST-7588
Product Name
Common for 24 VDC Module,
8 channels
Common for 24 VDC
Smart Module, 8 channels
Common for (4) 24 VDC
Channels and (4) 0 VDC
Channels
Common Smart Module for
(4) 24 VDC Channels and
(4) 0 VDC Channels
Lifecycle Status
Active
Active
Active
Active
Power Modules
Power Modules
Power Modules
Power Modules
No
Yes
No
Yes
Module Type
Smart Module (Uses Module ID)
Max. 10 Amps
Max. 10 Amps
Max. 10 Amps
Max. 10 Amps
LEDs
No
1 Green/Red LED, Module Status
No
1 Green/Red LED, Module Status
Diagnostic Supported
No
No
No
No
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Spring Clamp Terminal Block
None
Max. 18 mA @ 5 VDC
None
Max. 18 mA @ 5 VDC
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
Load Current per Point
Connector Type
Internal Power Used (5 VDC loading)
Dimensions (H x W x D) in mm
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 3.111
RSTi
Industrial I/O
Power Modules
The RSTi provides various power modules to reduce wiring and simplify installation. Modules that
support Smart Module ID will require one of the addresses on the bus.
The ST-7241 and ST-7641 enable multiple voltages to be supported on the RSTi bus such as 120
VAC. All modules to the right of the module will be based on the supply voltage of the ST-7x41.
The ST-7111 and ST-7511 boost the 5 VDC on the backplane bus when module power
requirement is exceeded. The ST-7x11 supplies 1.0 Amps of 5 VDC to the modules to the right
of the ST-7x11.
ST-7111
ST-7511
ST-7241
ST-7641
Product Name
Bus Expansion Power Supply
(Input 24 VDC,
Output 1.0 Amp/5 VDC)
Bus Expansion Smart Power
Supply (Input 24 VDC,
Output 1.0 Amp/5 VDC)
Power Distribution (5 VDC,
24 VDC, 48 VDC, 110 VAC,
220 VAC)
Power Distribution Smart
Module (5 VDC, 24 VDC, 48 VDC,
110 VAC, 220 VAC)
Lifecycle Status
Active
Active
Active
Active
Power Modules
Power Modules
Power Modules
Power Modules
No
Yes
No
Yes
Module Type
Smart Module (Uses Module ID)
Max. 10 Amps
Max. 10 Amps
Max. 10 Amps
Max. 10 Amps
LEDs
Yes
1 Green/Red LED, Module Status
No
1 Green/Red LED, Module Status
Diagnostic Supported
No
No
No
No
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Spring Clamp Terminal Block
Spring Clamp Terminal Block
1.0 Amp 5 VDC booster
Max. 14 mA @ 24 VDC
None
Max. 18 mA @ 5 VDC
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
99 x 12 x 70
Load Current per Point
Connector Type
Internal Power Used (5 VDC loading)
Dimensions (H x W x D) in mm
3.112
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Expansion Modules
The RSTi network interfaces can be extended beyond the initial bus. The ST-5725 master
can connect to a ST-5726 Slave. Up to 3 slave expansions are supported with a maximum
distance of 300 meters. Each Slave requires a Master module.
ST-5725
ST-5726
Product Name
Master expansion module
Slave expansion module
Lifecycle Status
Target Release August 2012
Target Release August 2012
Module Type
Features
Connector Type
Field Power Requirement
Internal Power Used (5 VDC loading)
Dimensions (H x W x D) in mm
www.ge-ip.com
Expansion Module
Expansion Module
Master module allows expansion of the RSTi Network
Interface unit. The distance between the master
and slave is 300 meters. Only 1 ST-5726 Slave unit is
supported by the master. Limited to 3 Master/Slave
combinations per Network Interface Unit.
Slave expansion requires a ST-5725 master module.
Spring Clamp Terminal Block or Cable
Spring Clamp Terminal Block or Cable
No Connection with Field Power
Field Power passes though to the next module
24 VDC (11 VDC to 28.8 VDC)
100 mA @ 5.0 VDC Maximum
160 mA @ 5.0 VDC Maximum
99 x 19.1 x 70
99 x 31 x 70
GE Intelligent Platforms Control Systems Solutions 3.113
RSTi
Industrial I/O
Powerful Configuration Tools
The RSTi is tightly integrated with the GE Intelligent Platforms Proficy Machine Edition. The user can easily select an I/O
module and configure parameters. The configuration is stored in the folder and once download to the controller it is
automatically loaded to the RSTi with a single point of connect.
Data is easily mapped
to reference memory or
symbolic
RSTi modules are part of
the controller hardware
configuration
Module pick list with
part number and brief
description
3.114
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
IO Guide Pro - Third Party Configuration Tool
The IO Guide Pro enables integrators network independence. I/O systems can be easily configured using the various RSTi
network interfaces. Changing from Ethernet IP to Profibus is as simple as a mouse click without impacting the rest of the I/O
configuration. The tool provides technical data, address mapping, product image and bus loading.
Network Interface
Configuration Tool
Profinet
Integrated into Proficy Machine Edition and also a GSDML file is available for other platforms
Profibus DP/V1
IO Guide Pro software tool and GSD file
DeviceNet
IO Guide Pro software tool and EDS file
Modbus TCP
IO Guide Pro software tool
Modbus Serial
IO Guide Pro software tool
EtherCAT
IO Guide Pro software tool
Ethernet IP
IO Guide Pro software tool and EDS file
CANOpen
IO Guide Pro software tool and EDS file
CC-Link
CSP file
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 3.115
RSTi
Industrial I/O
Accessories
STXACC004
End Module, 7pcs (included with network interface)
Active
STXRTB009
Removable Terminal Block, 9pcs (included with modules)
Active
STXACC001
MARKER 100pcs (included with modules)
Active
STXACC002
BLANK MARKER 100pcs
Active
STXCBL005
0.5 meter expansion cable for ST-5725 and ST-5726
Active
STXCBL010
1.0 meter expansion cable for ST-5725 and ST-5726
Active
STXCBL030
3.0 meter expansion cable for ST-5725 and ST-5726
Active
Expansion Cables
3.116
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Industrial I/O
RSTi
Examples of Typical Application
Profinet Network Interface
with (20) 24 VDC Positive Logic inputs, (12) 24 VDC Source outputs 2 Amps and (8) Relay outputs.
5 VDC RSTi Bus required (mA)
Qty
Part Number
Description
1500 mA of Provided
1
STXPNS001
ProfiNet RT Network Adapter
35 mA x 3 = 105 mA
3
ST-1228
8 points, Negative Logic, Source Input module 12V/ 24 VDC
45 mA x 3 = 135 mA
3
ST-2624
4 points, Source, 24 VDC/ 2 A
150 mA
1
ST-2748
Isolated Relay Output 8 Points, 230 VAC/ 2 A
Total:
5 VDC Current Required from Network Interface: 390 mA
Total 1500 mA @ 5 VDC available from STXPNS001 Profinet Network Adapter. Total I/O current requirement is 390 mA @ 5V.
No 5 VDC booster required.
Profinet Network Interface
with (40) 24 VDC inputs, (20) 24 VDC Outputs with ESCP protection, (20) Relay outputs also (6) 4 to 20 mA Analog Inputs, (3) Type J
Thermocouple, (4) 4 to 20 mA Analog Outputs, (14) 120 VAC Inputs and (8) 120 VAC Outputs
1500 mA of Provided
1
STXPNS001
ProfiNet RT Network Adapter
35 mA x 5 = 175 mA
5
ST-1228
8 points, Negative Logic, Source Input module 12V/ 24 VDC
60 mA x 3 = 180 mA
3
ST-2328
8 points output, Source, 24 VDC/ 0.5 A
150 mA x 3 = 450 mA
3
ST-2748
Isolated Relay Output 8 Points, 230 VAC/ 2 A
60 mA x 1 = 60 mA
1
ST-3218
Analog Input 8 Channels, 4~20 mA, 12 bit
120 mA x 1 = 120 mA
1
ST-3804
4 Channels, Thermocouple Connector Type
60 mA x 1 = 60 mA
1
ST-4214
Analog Out 4 Channels, 4~20 mA, 12 bit
18 mA x 1 = 18 mA
1
ST-7641*
Isolated Field Power Distribution 5, 24, 48, AC , 10 Amp with LED status
35 mA x 4 = 140 mA
4
ST-1804
4 points, 110 VAC (AC 85V ~ 132V) inputs
35 mA x 4 = 140 mA
4
ST-2852
Triac Output 2 points, 12V ~ 125 VAC/ 0.5 A
Total:
5 VDC Current Required from Network Interface: 1343 mA
Modules occupy 23 of the 32 module addresses available
Total 1500 mA @ 5 VDC available from STXPNS001 Profinet Network Adapter. Total I/O current requirement is 1343 mA @ 5V.
No 5 VDC booster required.
*ST-7641 is required for providing AC bus power to the ST-1804 and ST-2852. All bus power to the right of the ST-7641 will be AC.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions 3.117
Notes
3.118
GE Intelligent Platforms Control Systems Solutions
Industrial I/O
www.ge-ip.com
Operator Interfaces
Table of Contents
QuickPanel Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3
Controllers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.4
Communication Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.7
Starter Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.8
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.9
QuickPanel Control Europe, Middle East and Africa. . . . . . . . . . . . . . . . . . . . . . 4.10
Controllers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.11
Communication Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.13
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.14
QuickPanel View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.15
Operator Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.16
Starter Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.23
Communication Hardware and Accessories. . . . . . . . 4.26
QuickPanel View Europe, Middle East and Africa. . . . . . . . . . . . . . . . . . . . . . 4.27
Operator Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.28
Communication Hardware and Accessories. . . . . . . . 4.33
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
4.1
Table Of Contents
4.2
GE Intelligent Platforms Control Systems Solutions
Operator Interfaces
www.ge-ip.com
Operator Interfaces
QuickPanel Control
QuickPanel Control
GE Intelligent Platforms markets and
sells QuickPanel Control products that
are designed to meet the market
needs of companies in the Americas
and Asia Pacific.
QuickPanel Control is designed to
meet your converging control and
visualization application needs with
a combination of bright color TFT, or
monochrome touch screens, ­multiple
communication options and Proficy
Logic Developer—Machine Edition
and Proficy View—Machine Edition
software.
Features include:
• Display sizes from 6” to 15”
• Microsoft Windows® CE operating
system
• Expandable memory and
­communication expansion cards
• CompactFlash
Controllers
page 4.4
Communications Cards
page 4.7
Starter Kits
page 4.8
Accessories
page 4.9
• Functions from data collection and
trending to system security and
alarming
• Built-in web server for access to
data and panels via the Internet or
your Intranet using any standard
browser
• Communication to I/O using GE
Series 90-30 I/O Interface, VersaMax
I/O Interface, VersaMax Micro I/O
Interface, Genius I/O Interface, Open
Fieldbus and Ethernet Connectivity
• Multi-language support selectable
by the operator when the system
is online
• Common database for increased
productivity – greatly reduces
­development time by eliminating the
need to re-enter tag names
• Extensive library of pre-configured
animation objects
• UL Class 1 Div 2 (A, B, C, D), ATEX
Class 1 Zone 2, and CE Mark
Proficy Machine Edition
Proficy Machine Edition is an
advanced software environment for
the development and maintenance
of machine level automation.
Visualization, motion control, and
­execution logic are developed
with a single programmer.
Publication Reference Chart
GFK-2243
6 Inch QuickPanel View & Control Hardware Reference Guide
GFK-2507
8 Inch QuickPanel View & Control Hardware Reference Guide
GFK-2284
12 Inch QuickPanel View & Control Hardware Reference Guide
GFK-2402
15 inch QuickPanel View & Control Hardware Reference Guide
GFK-2245
GE Series 90-30 I/O Interface
GFK-2297
GE Genius I/O Interface
GFK-2299
GE VersaMax Expansion I/O Card
GFK-2270
DeviceNet Master Communication Card
GFK-2271
PROFIBUS Master Communication Card
GFK-2276
Expanded User Memory Installation Guide
GFK-2368
PCMCIA Adaptor
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
4.3
QuickPanel Control
Operator Interfaces
Controllers
QuickPanel Control combines control and visualization into one platform for maximum
­productivity and cost efficiency. By integrating the QuickPanel Control family of touch
screens with Proficy Machine Edition software, QuickPanel Control delivers flexible, scalable
­performance on a rugged hardware platform. The intuitive environment of Proficy Logic
Developer - Machine Edition Control and Proficy View - Machine Edition software helps
reduce application development time, and connectivity is made easy with a family of
Ethernet and Fieldbus interfaces.
IC754CSL06CTD
IC754CBL06CTD
IC754CSL06MTD
IC754CBL06MTD
Product Name
QuickPanel Control Display,
6” TFT-Color Loaded
QuickPanel Control Display,
6” TFT-Color Loaded
QuickPanel Control Display,
6” Monochrome Loaded
QuickPanel Control Display,
6” Monochrome Loaded
Lifecycle Status
Active
Active
Active
Active
Display Size
5.7 inch (Diagonal)
5.7 inch (Diagonal)
5.7 inch (Diagonal)
5.7 inch (Diagonal)
Display Type
TFT
TFT
Monochrome
Monochrome
320 x 240 pixels
320 x 240 pixels
320 x 240 pixels
320 x 240 pixels
32 MB
32 MB
32 MB
32 MB
to 64 MB or 96 MB
to 64 MB or 96 MB
to 64 MB or 96 MB
to 64 MB or 96 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
RS232
RS232
RS232
RS232
Ethernet: LAN #1
10/100 Mbps
10/100 Mbps
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
None
None
None
None
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Agency Approvals
GE Series 90-30 I/O,
GE Series 90-30 I/O,
GE Series 90-30 I/O,
GE Series 90-30 I/O,
VersaMax Expansion I/O,
VersaMax Expansion I/O,
VersaMax Expansion I/O,
VersaMax Expansion I/O,
VersaMax Micro Expansion I/O, VersaMax Micro Expansion I/O, VersaMax Micro Expansion I/O, VersaMax Micro Expansion I/O,
Genius I/O, DeviceNet Master, Genius I/O, DeviceNet Master, Genius I/O, DeviceNet Master, Genius I/O, DeviceNet Master,
and PROFIBUS Master
and PROFIBUS Master
and PROFIBUS Master
and PROFIBUS Master
One, Type 2
One, Type 2
One, Type 2
One, Type 2
UL/cUL-Class 1 Div 2 (A, B, C, D); UL/cUL-Class 1 Div 2 (A, B, C, D); UL/cUL-Class 1 Div 2 (A, B, C, D); UL/cUL-Class 1 Div 2 (A, B, C, D);
ATEX-Class 1 Zone 2; CE Mark
ATEX-Class 1 Zone 2; CE Mark
ATEX-Class 1 Zone 2; CE Mark
ATEX-Class 1 Zone 2; CE Mark
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
Panel Cut-Out (W x H x D)
6.14” x 4.86” x 2.76”
(158mm x 126mm x 70mm)
6.14” x 4.86” x 2.76”
(158mm x 126mm x 70mm)
6.14” x 4.86” x 2.76”
(158mm x 126mm x 70mm)
6.14” x 4.86” x 2.76”
(158mm x 126mm x 70mm)
Front of Panel and Depth (W x H x D)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 22mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 22mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 22mm)
"8.00” x 6.17” x 0.85”
(203mm x 157mm x 22mm)
Input Voltage
12 to 30.0 VDC
12 to 30.0 VDC
12 to 30.0 VDC
12 to 30.0 VDC
Power
Less than 24 W
Less than 24 W
Less than 24 W
Less than 24 W
Operating Temperature
-10 to 60°C
(14 to 140°F)
-10 to 60°C
(14 to 140°F)
-10 to 60°C
(14 to 140°F)
-10 to 60°C
(14 to 140°F)
Storage Temperature
-20 to 70°C
(-4 to 158°F)
-20 to 70°C
(-4 to 158°F)
-20 to 70°C
(-4 to 158°F)
-20 to 70°C
(-4 to 158°F)
5 - 90% non-condensing
5 - 90% non-condensing
10 - 85% non-condensing
10 - 85% non-condensing
2 Bi-color, 2 on
Ethernet Connector
2 Bi-color, 2 on
Ethernet Connector
2 Bi-color, 2 on
Ethernet Connector
2 Bi-color, 2 on
Ethernet Connector
Environmental Rating
Operating Humidity
Indicators - LEDs
4.4
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Operator Interfaces
QuickPanel Control
Controllers
QuickPanel Control combines control and visualization into one platform for maximum
­productivity and cost efficiency. By integrating the QuickPanel Control family of touch
screens with Proficy Machine Edition software, QuickPanel Control delivers flexible, scalable
­performance on a rugged hardware platform. The intuitive environment of Proficy Logic
Developer - Machine Edition Control and Proficy View - Machine Edition software helps
reduce application development time, and connectivity is made easy with a family of
Ethernet and Fieldbus interfaces.
IC754CSF06CTD
IC754CSX06CTD
IC754CBF08CTD
Product Name
QuickPanel Control Display,
6” TFT-Color Fully Loaded
QuickPanel Control Display,
6” TFT-Color Extra Fully Loaded
QuickPanel Control Display,
8” TFT-Color Loaded
Lifecycle Status
Active
Active
Active
Display Size
5.7 inch (Diagonal)
5.7 inch (Diagonal)
8.4 Inch (Diagonal)
Display Type
TFT
TFT
TFT
320 x 240 pixels
320 x 240 pixels
800 x 600 pixels
64 MB
64 MB
64 MB
to 128 MB
to 128 MB
to 128 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
RS232
RS232
RS232
Ethernet: LAN #1
10/100 Mbps
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
None
None
None
GE Series 90-30 I/O,
VersaMax Expansion I/O,
VersaMax Micro Expansion I/O,
Genius I/O, DeviceNet Master,
and PROFIBUS Master
GE Series 90-30 I/O,
VersaMax Expansion I/O,
VersaMax Micro Expansion I/O,
Genius I/O, DeviceNet Master,
and PROFIBUS Master
GE Series 90-30 I/O,
VersaMax Expansion I/O,
VersaMax Micro Expansion I/O,
Genius I/O, DeviceNet Master
and PROFIBUS Master
One, Type 2
One, Type 2
One, Type 2
UL/cUL-Class 1 Div 2 (A, B, C, D);
ATEX-Class 1 Zone 2; CE Mark
UL/cUL-Class 1 Div 2 (A, B, C, D);
ATEX-Class 1 Zone 2; CE Mark
UL/cUL-Class 1 Div 2 (A, B, C, D);
ATEX-Class 1 Zone 2; CE Mark
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X, UL50 Type 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
Panel Cut-Out (W x H x D)
6.14” x 4.86” x 2.76”
(158mm x 126mm x 70mm)
6.14” x 4.86” x 2.76”
(158mm x 126mm x 70mm)
8.97” x 7.34” x 3.03”
(227.8mm x 186.4mm x 76.9mm)
Front of Panel and Depth (W x H x D)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 22mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 22mm)
9.8” x 8.18” x 0.35”
(248.9mm x 207.7mm x 9mm)
Input Voltage
12 to 30.0 VDC
12 to 30.0 VDC
10.8 to 30.0 VDC
Power
Less than 24 W
Less than 24 W
Less than 24 W
Operating Temperature
-10 to 60°C
(14 to 140°F)
-10 to 60°C
(14 to 140°F)
0 to 60°C
(32 to 140°F)
Storage Temperature
-20 to 70°C
(-4 to 158°F)
-20 to 70°C
(-4 to 158°F)
-20 to 70°C
(-4 to 158°F)
5 - 90% non-condensing
5 - 90% non-condensing
10% - 85% non-condensing
2 Bi-color, 2 on
Ethernet Connector
2 Bi-color, 2 on
Ethernet Connector
2 Bi-color, 2 on
Ethernet Connector
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Agency Approvals
Environmental Rating
Operating Humidity
Indicators - LEDs
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
4.5
QuickPanel Control
Operator Interfaces
Controllers
QuickPanel Control combines control and visualization into one platform for maximum
­productivity and cost efficiency. By integrating the QuickPanel Control family of touch
screens with Proficy Machine Edition software, QuickPanel Control delivers flexible, scalable
­performance on a rugged hardware platform. The intuitive environment of Proficy Logic
Developer - Machine Edition Control and Proficy View - Machine Edition software helps
reduce application development time, and connectivity is made easy with a family of
Ethernet and Fieldbus interfaces.
IC754CSF12CTD
IC754CSF15CTD
IC754CBF15CTD
Product Name
QuickPanel Control Display,
12” TFT-Color Loaded
QuickPanel Control Display,
15” TFT-Color Loaded
QuickPanel Control Display,
15” TFT-Color Loaded
Lifecycle Status
Active
Active
Active
Display Size
12.1 inch (Diagonal)
15.1 inch (Diagonal)
15.1 inch (Diagonal)
Display Type
TFT
TFT
TFT
800 x 600 pixels
1024 x 768 pixels
1024 x 768 pixels
64 MB
64 MB
64 MB
to 96 MB or 128 MB
to 96 MB or 128 MB
to 96 MB or 128 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
RS232
RS232
RS232
Ethernet: LAN #1
10/100 Mbps
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
10/100 Mbps
10/100 Mbps
10/100 Mbps
GE Series 90-30 I/O,
VersaMax Expansion I/O,
VersaMax Micro Expansion I/O,
Genius I/O, DeviceNet Master,
and PROFIBUS Master
GE Series 90-30 I/O,
VersaMax Expansion I/O,
VersaMax Micro Expansion I/O,
Genius I/O, DeviceNet Master,
and PROFIBUS Master
GE Series 90-30 I/O,
VersaMax Expansion I/O,
VersaMax Micro Expansion I/O,
Genius I/O, DeviceNet Master,
and PROFIBUS Master
One, Type 2
One, Type 2
One, Type 2
UL/cUL-Class 1 Div 2 (A, B, C, D);
ATEX-Class 1 Zone 2; CE Mark
UL/cUL-Class 1 Div 2 (A, B, C, D);
ATEX-Class 1 Zone 2; CE Mark
UL/cUL-Class 1 Div 2 (A, B, C, D);
ATEX-Class 1 Zone 2; CE Mark
Environmental Rating
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
Panel Cut-Out (W x H x D)
11.88” x 8.96” x 2.37”
(302mm x 228mm x 60mm)
14.93” x 12.03” x 2.78”
(379mm x 305mm x 71mm)
14.93” x 12.03” x 2.78”
(379mm x 305mm x 71mm)
Front of Panel and Depth (W x H x D)
13.26” x 10.34” x 0.38”
(337mm x 263mm x 10mm)
15.70” x 12.73” x 0.40”
(399mm x 323mm x 10mm)
15.70” x 12.73” x 0.40”
(399mm x 323mm x 10mm)
12 VDC @ ±20% or 24 VDC @ ±20%
12 VDC @ ±20% or 24 VDC @ ±20%
12 VDC @ ±20% or 24 VDC @ ±20%
Less than 48 W
Less than 60 W
Less than 60 W
Operating Temperature
0 to 50°C
(32 to 122°F)
0 to 50°C
(32 to 122°F)
0 to 50°C
(32 to 122°F)
Storage Temperature
-20 to 70°C
(-4 to 158°F)
-20 to 70°C
(-4 to 158°F)
-20 to 70°C
(-4 to 158°F)
10 - 85% non-condensing
10 - 85% non-condensing
10 - 85% non-condensing
2 Bi-color, 2 on
Ethernet Connector
2 Bi-color, 2 on
Ethernet Connector
2 Bi-color, 2 on
Ethernet Connector
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Agency Approvals
Input Voltage
Power
Operating Humidity
Indicators - LEDs
4.6
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Operator Interfaces
QuickPanel Control
Communications Cards
GE 90-30 I/O Interface Card allows the QuickPanel Control unit to interface directly to 90-30
expansion racks using an expansion cable. GE VersaMax Expansion I/O Interface Card
allows the QuickPanel Control unit to interface directly to VersaMax I/O interfacing to a
VersaMax ERM. GE Genius Interface Card allows the QuickPanel Control unit to interface to
devices on a Genius network and act as a controller. DeviceNet - Master Interface Card
allows the QuickPanel Control unit to interface to devices on a DeviceNet Network acting as
the master. PROFIBUS - Master Interface Card allows the QuickPanel Control unit to interface to devices on a PROFIBUS Network acting as the master.
IC754PIF001
IC754TAN001
IC754UEX001
IC754GEN001
IC754DVNM01
IC754PBSM01
Product Name
GE
Series 90-30
Expansion I/O
Interface for
QuickPanel Control
GE
VersaMax
Expansion I/O
Interface for
QuickPanel Control
GE
VersaMax Micro
Expansion I/O
Interface for
QuickPanel Control
GE
Genius
Communication
Card for
QuickPanel Control
DeviceNet Master Interface
Card for
QuickPanel Control
PROFIBUS Master Interface
Card for
QuickPanel Control
Lifecycle Status
Active
Active
Active
Active
Active
Active
90-30
I/O Expansion
VersaMax
Expansion I/O
VersaMax Micro
Expansion I/O
Genius Interface
DeviceNet Master
PROFIBUS Master
Fieldbus Type
Agency Approvals
Operating Temperature
www.ge-ip.com
UL/cUL-Class 1 Div 2 UL/cUL-Class 1 Div 2 UL/cUL-Class 1 Div 2 UL/cUL-Class 1 Div 2 UL/cUL-Class 1 Div 2 UL/cUL-Class 1 Div 2
(A, B, C, D);
(A, B, C, D);
(A, B, C, D);
(A, B, C, D);
(A, B, C, D)
(A, B C, D)
ATEX-Class 1 Zone 2; ATEX-Class 1 Zone 2; ATEX-Class 1 Zone 2; ATEX-Class 1 Zone 2;
CE Mark
CE Mark
CE Mark
CE Mark
0 to 60°C
(32 to 140°F)
0 to 60°C
(32 to 140°F)
0 to 60°C
(32 to 140°F)
0 to 60°C
(32 to 140°F)
0 to 60°C
(32 to 140°F)
0 to 60°C
(32 to 140°F)
GE Intelligent Platforms Control Systems Solutions
4.7
QuickPanel Control
Operator Interfaces
Starter Kits
Starter Kits are an ideal package for first time users. The kits include a QuickPanel Control
unit, Proficy Machine Edition software, 24 VDC power supply and Ethernet cable. QuickPanel
Control combines control and visualization into one platform for maximum productivity and
cost efficiency. By integrating the QuickPanel family of touch screens with Proficy Machine
Edition software, QuickPanel Control delivers flexible, scalable performance on a rugged
hardware platform. The intuitive environment of Proficy Machine Edition software helps
reduce application development time, and connectivity is made easy with a family of
Ethernet and Fieldbus interfaces.
IC754CKL06CTD
IC754CKL06MTD
IC754CKF12CTD
IC754CKF15CTD
Product Name
QuickPanel Control Starter
Kit, includes Display,
6” TFT
QuickPanel Control Starter Kit,
includes Display,
6” Monochrome
QuickPanel Control Starter
Kit, includes Display,
12” TFT
QuickPanel Control Starter
Kit, includes Display,
15” TFT
Lifecycle Status
Active
Active
Active
Active
Display Size
5.7 inch (Diagonal)
5.7 inch (Diagonal)
12.1 inch (Diagonal)
15.1 inch (Diagonal)
Display Type
TFT
Monochrome
TFT
TFT
320 x 240 pixels
320 x 240 pixels
800 x 600 pixels
1024x768 pixels
32 MB
32 MB
64 MB
64 MB
to 64 MB or 96 MB
to 64 MB or 96 MB
to 96 MB or 128 MB
to 96 MB or 128 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
RS232
RS232
RS232
RS232
Ethernet: LAN #1
10/100 Mbps
10/100 Mbps
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
None
None
10 Mbps
10/100 Mbps
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Agency Approvals
GE Series 90-30 I/O,
GE Series 90-30 I/O,
GE Series 90-30 I/O,
GE Series 90-30 I/O,
VersaMax Expansion I/O,
VersaMax Expansion I/O,
VersaMax Expansion I/O,
VersaMax Expansion I/O,
VersaMax Micro Expansion I/O, VersaMax Micro Expansion I/O, VersaMax Micro Expansion I/O, VersaMax Micro Expansion I/O,
Genius I/O, DeviceNet Master, Genius I/O, DeviceNet Master, Genius I/O, DeviceNet Master, Genius I/O, DeviceNet Master,
and PROFIBUS Master
and PROFIBUS Master
and PROFIBUS Master
and PROFIBUS Master
One, Type 2
One, Type 2
One, Type 2
One, Type 2
UL/cUL-Class 1 Div 2 (A, B, C, D); UL/cUL-Class 1 Div 2 (A, B, C, D); UL/cUL-Class 1 Div 2 (A, B, C, D); UL/cUL-Class 1 Div 2 (A, B, C, D);
ATEX-Class 1 Zone 2; CE Mark
ATEX-Class 1 Zone 2; CE Mark
ATEX-Class 1 Zone 2; CE Mark
ATEX-Class 1 Zone 2; CE Mark
Environmental Rating
NEMA 4/12/4X
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X
IP65 when properly mounted
in an IP65 rated enclosure
Panel Cut-Out (W x H x D)
6.14” x 4.86” x 2.76”
(158mm x 126mm x 70mm)
6.14” x 4.86” x 2.76”
(158mm x 126mm x 70mm)
11.88” x 8.96” x 2.37”
(302mm x 228mm x 60mm)
14.93” x 12.03” x 2.78”
(379mm x 305mm x 71mm)
Front of Panel and Depth (W x H x D)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 22mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 22mm)
13.26” x 10.34” x 0.38”
(337mm x 263mm x 10mm)
15.70” x 12.73” x 0.40”
(399mm x 323mm x 10mm)
10.8 to 30.0 VDC
10.8 to 30.0 VDC
12 VDC @ ±20% or
24 VDC @ ±20%
12 VDC @ ±20% or
24 VDC @ ±20%
Less than 24 W
Less than 24 W
Less than 48 W
Less than 60 W
Operating Temperature
0 to 60°C
(32 to 140°F)
-10 to 60°C
(14 to 140°F)
0 to 50°C
(32 to 122°F)
0 to 50°C
(32 to 122°F)
Storage Temperature
-20 to 70°C
(-4 to 158°F)
-20 to 70°C
(-4 to 158°F)
-20 to 70°C
(-4 to 158°F)
-20 to 60°C
(-4 to 140°F)
5 - 95% non-condensing
10 - 85% non-condensing
10 - 90% non-condensing
10 - 90% non-condensing
2 Bi-color, 2 on
Ethernet Connector
2 Bi-color, 2 on
Ethernet Connector
2 Bi-color, 2 on
Ethernet Connector
2 Bi-color, 2 on
Ethernet Connector
Input Voltage
Power
Operating Humidity
Indicators - LEDs
4.8
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Operator Interfaces
QuickPanel Control
Accessories
IC754PCMCIA001
PCMCIA Adaptor for QuickPanel Control
Active
IC754ACC32MEM
Expansion Memory 32 MBytes
Active
IC754ACC64MEM
Expansion Memory 64 MBytes
Active
IC754ACC06GAS
Gasket for 6 Inch QuickPanel Control
Active
IC754ACC12GAS
Gasket for 12 Inch QuickPanel Control
Active
IC754ACC15GAS
Gasket for 15 Inch QuickPanel Control
Active
IC754ACC06MNT
Mounting Clips & Power Connector for 6 Inch QuickPanel Control
Active
IC754ACC12MNT
Mounting Clips & Power Connector for 12 Inch QuickPanel Control
Active
IC754ACC15MNT
Mounting Clips & Power Connector for 15 Inch QuickPanel Control
Active
IC754ACC06BEZ01
Stainless Steel Bezel for 6 Inch Mono & TFT-Color QuickPanel Control
Active
IC754ACC12BEZ01
Stainless Steel Bezel for 12 Inch TFT-Color QuickPanel Control
Active
IC754ACC08ADP
8 Inch Adapter Kit to accomadate 9 Inch Legacy Quick Panel Cut-out
Active
IC754ACC12ADP
Adaptor Kit for 12 Inch QuickPanel Control into CEIIx Cut-out
Active
IC754BEZ06GAS
Replacement Gasket for 6 Inch Stainless Steel Bezel
Active
IC754BEZ12GAS
Replacement Gasket for 12 Inch Stainless Steel Bezel
Active
IC754UEX05CBL
VersaMax Micro Expansion I/O Cable - 0.5 Meter
Active
IC754UEX10CBL
VersaMax Micro Expansion I/O Cable - 1.0 Meter
Active
IC754ACC06BEZ02
Stainless Steel Bezel for 6 Inch STN-Color Display
Active
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
4.9
QuickPanel Control - Europe, Middle East and Africa
Operator Interfaces
QuickPanel Control-Europe, Middle East and Africa
GE Intelligent Platforms markets and
sells QuickPanel Control products that
are designed to meet the market
needs of companies in Europe, the
Middle East and Africa.
QuickPanel Control is designed to
meet your converging control and
visualization application needs with
a combination of bright color TFT, or
monochrome touch screens, ­multiple
communication options and Proficy
Logic Developer—Machine Edition
and Proficy View—Machine Edition
software.
Features include:
• Display sizes from 6” to 15”
• Microsoft Windows® CE operating
system
• Expandable memory and
­communication expansion cards
• CompactFlash
Controllers
page 4.11
Communications Cards
page 4.13
Accessories
page 4.14
• Functions from data collection and
trending to system security and
alarming
• Built-in web server for access to
data and panels via the Internet or
your Intranet using any standard
browser
• Communication to I/O using GE
Series 90-30 I/O Interface, VersaMax
I/O Interface, VersaMax Micro I/O
Interface, Genius I/O Interface, Open
Fieldbus and Ethernet Connectivity
• Multi-language support selectable
by the operator when the system
is online
• Common database for increased
productivity – greatly reduces
­development time by eliminating the
need to re-enter tag names
• Extensive library of pre-configured
animation objects
• UL Class 1 Div 2 (A, B, C, D), ATEX
Class 1 Zone 2, and CE Mark
Proficy Machine Edition
Proficy Machine Edition is an
advanced software environment for
the development and maintenance
of machine level automation.
Visualization, motion control, and
­execution logic are developed
with a single programmer.
Publication Reference Chart
GFK-2305
6 Inch QuickPanel Control (Euro-Loaded) Hardware Reference Guide
GFK-2507
8 Inch QuickPanel View & Control Hardware Reference Guide
GFK-2284
12 Inch QuickPanel View & Control Hardware Reference Guide
GFK-2402
15 inch QuickPanel View & Control Hardware Reference Guide
GFK-2245
GE Series 90-30 I/O Interface
GFK-2297
GE Genius I/O Interface
GFK-2299
GE VersaMax Expansion I/O Card
GFK-2270
DeviceNet Master Communication Card
GFK-2271
PROFIBUS Master Communication Card
GFK-2276
Expanded User Memory Installation Guide
GFK-2368
PCMCIA Adaptor
4.10
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Operator Interfaces
QuickPanel Control - Europe, Middle East and Africa
Controllers
QuickPanel Control combines control and visualization into one platform for maximum
­productivity and cost efficiency. By integrating the QuickPanel Control family of touch
screens with Proficy Machine Edition software, QuickPanel Control delivers flexible, scalable
­performance on a rugged hardware platform. The intuitive environment of Proficy Logic
Developer - Machine Edition Control and Proficy View - Machine Edition software helps
reduce application development time, and connectivity is made easy with a family of
Ethernet and Fieldbus interfaces.
IC754CGL06CTD
IC754CHL06CTD
IC754CGL06MTD
IC754CHL06MTD
Product Name
QuickPanel Control Display,
6” TFT-Color Loaded
QuickPanel Control Display,
6” TFT-Color Loaded
QuickPanel Control Display,
6” Monochrome Loaded
QuickPanel Control Display,
6” Monochrome Loaded
Lifecycle Status
Active
Active
Active
Active
Display Size
5.7 Inch (Diagonal)
5.7 Inch (Diagonal)
5.7 Inch (Diagonal)
5.7 Inch (Diagonal)
Display Type
TFT
TFT
Monochrome
Monochrome
320 x 240 pixels
320 x 240 pixels
320 x 240 pixels
320 x 240 pixels
32 MB
32 MB
32 MB
32 MB
to 64 MB or 96 MB
to 64 MB or 96 MB
to 64 MB or 96 MB
to 64 MB or 96 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
RS232
RS232
RS232
RS232
Ethernet: LAN #1
10/100 Mbps
10/100 Mbps
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
None
None
None
None
GE Series 90-30 I/O,
VersaMax Expansion I/O,
VersaMax Micro Expansion
I/O, Genius I/O, DeviceNet
Master, and PROFIBUS Master
GE Series 90-30 I/O,
VersaMax Expansion I/O,
VersaMax Micro Expansion
I/O, Genius I/O, DeviceNet
Master, and PROFIBUS Master
GE Series 90-30 I/O,
VersaMax Expansion I/O,
VersaMax Micro Expansion
I/O, Genius I/O, DeviceNet
Master and PROFIBUS Master
GE Series 90-30 I/O,
VersaMax Expansion I/O,
VersaMax Micro Expansion
I/O, Genius I/O, DeviceNet
Master and PROFIBUS Master
One, Type 2
One, Type 2
One, Type 2
One, Type 2
UL/cUL-Class 1 Div 2 (A, B,
C, D); ATEX-Class 1 Zone 2;
CE Mark
UL/cUL-Class 1 Div 2 (A, B,
C, D); ATEX-Class 1 Zone 2;
CE Mark
UL/cUL-Class 1 Div 2 (A, B,
C, D); ATEX-Class 1 Zone 2;
CE Mark
UL/cUL-Class 1 Div 2 (A, B,
C, D); ATEX-Class 1 Zone 2;
CE Mark
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Agency Approvals
Environmental Rating
Panel Cut-Out (W x H x D)
156mm x 123.5mm x 70mm
156mm x 123.5mm x 70mm
156mm x 123.5mm x 70mm
156mm x 123.5mm x 70mm
(6.14” x 4.86” x 2.76”) or
(6.14” x 4.86” x 2.76”) or
(6.14” x 4.86” x 2.76”) or
(6.14” x 4.86” x 2.76”) or
200mm x 155.45mm x 85.1mm 200mm x 155.45mm x 85.1mm 200mm x 155.45mm x 85.1mm 200mm x 155.45mm x 85.1mm
(7.95” x 6.12” x 3.35”)
(7.95” x 6.12” x 3.35”)
(7.95” x 6.12” x 3.35”)
(7.95” x 6.12” x 3.35”)
216mm x 170mm x 28.7mm
(8.5” x 6.68” x 1.13”) or
216mm x 170mm x 7.11mm
(8.5” x 6.68” x 0.28”)
216mm x 170mm x 28.7mm
(8.5” x 6.68” x 1.13”) or
216mm x 170mm x 7.11mm
(8.5” x 6.68” x 0.28”)
216mm x 170mm x 28.7mm
(8.5” x 6.68” x 1.13”) or
216mm x 170mm x 7.11mm
(8.5” x 6.68” x 0.28”)
216mm x 170mm x 28.7mm
(8.5” x 6.68” x 1.13”) or
216mm x 170mm x 7.11mm
(8.5” x 6.68” x 0.28”)
Input Voltage
12.0 to 30.0 VDC
12.0 to 30.0 VDC
12.0 to 30.0 VDC
12.0 to 30.0 VDC
Power
Less than 24 W
Less than 24 W
Less than 24 W
Less than 24 W
Operating Temperature
-10 to 60°C (14 to 140°F)
-10 to 60°C (14 to 140°F)
-10 to 60°C (14 to 140°F)
-10 to 60°C (14 to 140°F)
Storage Temperature
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
5% - 90% non-condensing
5% - 90% non-condensing
10% - 85% non-condensing
10% - 85% non-condensing
2 Bi-color,
2 on Ethernet Connector
2 Bi-color,
2 on Ethernet Connector
2 Bi-color,
2 on Ethernet Connector
2 Bi-color,
2 on Ethernet Connector
Bezel Dimensions and Depth (W x H x D)
Operating Humidity
Indicators - LEDs
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
4.11
QuickPanel Control - Europe, Middle East and Africa
Operator Interfaces
Controllers
QuickPanel Control combines control and visualization into one platform for maximum
­productivity and cost efficiency. By integrating the QuickPanel Control family of touch
screens with Proficy Machine Edition software, QuickPanel Control delivers flexible, scalable
­performance on a rugged hardware platform. The intuitive environment of Proficy Logic
Developer - Machine Edition Control and Proficy View - Machine Edition software helps
reduce application development time, and connectivity is made easy with a family of
Ethernet and Fieldbus interfaces.
IC754CGF08CTD
IC754CGF12CTD
IC754CGF15CTD
Product Name
QuickPanel Control Display,
8” TFT-Color Loaded
QuickPanel Control Display,
12” TFT-Color Loaded
QuickPanel Control Display,
15” TFT-Color Loaded
Lifecycle Status
Active
Active
Active
Display Size
8.4 Inch (Diagonal)
12.1 Inch (Diagonal)
15.1 Inch (Diagonal)
Display Type
TFT
TFT
TFT
800 x 600 pixels
800 x 600 pixels
1024 x 768 pixels
64 MB
64 MB
64 MB
to 128 MB
to 96 MB or 128 MB
to 128 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
RS232
RS232
RS232
10/100 Mbps
10/100 Mbps
10/100 Mbps
Resolution
Memory: DRAM
Memory: Expandable
Ethernet: LAN #1
Ethernet: LAN #2
None
10/100 Mbps
10/100 Mbps
GE Series 90-30 I/O,
VersaMax Expansion I/O,
VersaMax Micro Expansion I/O,
Genius I/O, DeviceNet Master
and PROFIBUS Master
GE Series 90-30 I/O,
VersaMax Expansion I/O,
VersaMax Micro Expansion I/O,
Genius I/O, DeviceNet Master,
and PROFIBUS Master
GE Series 90-30 I/O,
VersaMax Expansion I/O,
VersaMax Micro Expansion I/O,
Genius I/O, DeviceNet Master,
and PROFIBUS Master
One, Type 2
One, Type 2
One, Type 2
Agency Approvals
UL/cUL-Class 1 Div 2 (A, B, C, D);
ATEX-Class 1 Zone 2;
CE Mark
UL/cUL-Class 1 Div 2 (A, B, C, D);
ATEX-Class 1 Zone 2;
CE Mark
UL/cUL-Class 1 Div 2 (A, B, C, D);
ATEX-Class 1 Zone 2;
CE Mark
Environmental Rating
NEMA 4/4X, UL50 Type 4/4X,
IP65 when properly mounted in
an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted in
an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted in
an IP65 rated enclosure
227.8mm x 186.4mm x 76.9mm
(8.97” x 7.34” x 3.03”)
301.8mm x 227.6mm x 60.2mm
(11.88” x 8.96” x 2.37”)
379mm x 305mm x 71mm
(14.93” x 12.03” x 2.78”)
248.9mm x 207.7mm x 9mm
(9.8” x 8.18” x 0.35”)
337mm x 263mm x 10mm
(13.26” x 10.34” x 0.38”)
399mm x 323mm x 10mm
(15.70” x 12.73” x 0.40”)
Input Voltage
10.8 to 30.0 VDC
12 VDC @ ±20% or 24 VDC @ ±20%
12 VDC @ ±20% or 24 VDC @ ±20%
Power
Less than 24 W
Less than 48 W
Less than 60 W
0 to 60°C (32 to 140°F)
0 to 50°C (32 to 122°F)
0 to 50°C (32 to 122°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 60°C (-4 to 140°F)
10% - 85% non-condensing
10 - 85% non-condensing
10 - 85% non-condensing
2 Bi-color,
2 on Ethernet Connector
2 Bi-color,
2 on Ethernet Connector
2 Bi-color,
2 on Ethernet Connector
Communication Expansion
Compact Flash
Panel Cut-Out (W x H x D)
Bezel Dimensions and Depth (W x H x D)
Operating Temperature
Storage Temperature
Operating Humidity
Indicators - LEDs
4.12
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Operator Interfaces
QuickPanel Control - Europe, Middle East and Africa
Communications Cards
GE 90-30 I/O Interface Card allows the QuickPanel Control unit to interface directly to 90-30
expansion racks using an expansion cable. GE VersaMax Expansion I/O Interface Card
allows the QuickPanel Control unit to interface directly to VersaMax I/O interfacing to a
VersaMax ERM. GE Genius Interface Card allows the QuickPanel Control unit to interface to
devices on a Genius network and act as a controller. DeviceNet - Master Interface Card
allows the QuickPanel Control unit to interface to devices on a DeviceNet Network acting as
the master. PROFIBUS - Master Interface Card allows the QuickPanel Control unit to interface to devices on a PROFIBUS Network acting as the master.
IC754PIF001
IC754TAN001
IC754UEX001
IC754GEN001
IC754DVNM01
IC754PBSM01
Product Name
GE 90-30 I/O
Interface Card
for QuickPanel
Control
Lifecycle Status
Active
Active
Active
Active
Active
Active
90-30 I/O Interface
VersaMax
Expansion I/O
VersaMax Micro
Expansion I/O
Genius Interface
DeviceNet Master
PROFIBUS Master
UL/cUL-Class 1 Div
2 (A, B, C, D);
ATEX-Class 1 Zone
2; CE Mark
UL/cUL-Class 1 Div
2 (A, B, C, D);
ATEX-Class 1 Zone
2; CE Mark
UL/cUL-Class 1 Div
2 (A, B, C, D);
ATEX-Class 1 Zone
2; CE Mark
UL/cUL-Class 1 Div
2 (A, B, C, D);
ATEX-Class 1 Zone
2; CE Mark
UL/cUL-Class 1
Div 2 (A, B, C, D)
UL/cUL-Class 1
Div 2 (A, B C, D)
0 to 60°C
(32 to 140°F)
0 to 60°C
(32 to 140°F)
0 to 60°C
(32 to 140°F)
0 to 60°C
(32 to 140°F)
0 to 60°C
(32 to 140°F)
0 to 60°C
(32 to 140°F)
Fieldbus Type
Agency Approvals
Operating Temperature
www.ge-ip.com
GE VersaMax
GE VersaMax Micro
Expansion I/O
Expansion I/O
Interface Card for
Interface for
QuickPanel Control QuickPanel Control
GE Genius
Interface Card
for QuickPanel
Control
DeviceNet - Master PROFIBUS - Master
Interface Card
Interface Card
for QuickPanel
for QuickPanel
Control
Control
GE Intelligent Platforms Control Systems Solutions
4.13
QuickPanel Control - Europe, Middle East and Africa
Operator Interfaces
Accessories
IC754PCMCIA001
PCMCIA Adaptor for QuickPanel Control
Active
IC754ACC32MEM
Expansion Memory 32 MBytes
Active
IC754ACC64MEM
Expansion Memory 64 MBytes
Active
IC754ACC06GASE
Gasket for 6 Inch QuickPanel Control
Active
IC754ACC12GAS
Gasket for 12 Inch QuickPanel Control
Active
IC754ACC15GAS
Gasket for 15 Inch QuickPanel Control
Active
IC754ACC06MNTE
Mounting Clips & Power Connector for 6 Inch QuickPanel Control
Active
IC754ACC12MNT
Mounting Clips & Power Connector for 12 Inch QuickPanel Control
Active
IC754ACC15MNT
Mounting Clips & Power Connector for 15 Inch QuickPanel Control
Active
IC754ACC06BEZ01
Stainless Steel Bezel for 6 Inch Mono & TFT-Color QuickPanel Control
Active
IC754ACC12BEZ01
Stainless Steel Bezel for 12 Inch TFT-Color QuickPanel Control
Active
IC754ACC12ADP
Adaptor Kit for 12 Inch QuickPanel Control into CEIIx Cut-out
Active
4.14
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Operator Interfaces
QuickPanel View
QuickPanel View
GE Intelligent Platforms markets and
sells QuickPanel View products that
are designed to meet the market
needs of companies in the Americas
and Asia Pacific.
QuickPanel View bundled visualization
solution provides the tools required for
today’s application needs. By integrating the QuickPanel family of touch
screens with Proficy Machine Edition
software, QuickPanel View delivers
flexible, scalable performance on a
rugged hardware platform. The intuitive environment of Proficy View –
Machine Edition software helps reduce
application development time, and
connectivity is made easy with a
­family of serial, Ethernet and
Fieldbus interfaces.
Operator Interfaces
pages 4.16-4.22
Starter Kits
pages 4.23-4.25
Communication Hardware
and Accessories
Features include:
• Display sizes from 6” to 15”
• Choice of Monochrome, Color-STN,
or Color-TFT display
• Microsoft Windows® CE operating
system
• Expandable memory and Fieldbus
cards†
• CompactFlash†
• Functions from data collection
and trending to system security
and alarming
• Built-in web server for access
to data, and panels using any
standard browser†
• Communication over serial,
Ethernet, and communication
expansion cards†
• Multi-language support selectable
by the operator when the system
is online
• Shared tags for increased
productivity – applications ­developed
for QuickPanel View can share tags
with other Proficy Machine Edition
applications, eliminating the need to
enter the data more than once
• Migration of applications developed
with QuickDesigner
• Extensive library of pre-configured
animation objects
• UL Class 1 Div 2 (A, B, C, D), ATEX
Class 1, Zone 2, CE Mark
• Web publishing
Available on select models. See following pages for availability.
†
Proficy Machine Edition
Proficy Machine Edition is an
advanced software environment for
the development and maintenance
of machine level automation.
Visualization, motion control and
­execution logic are developed with
a single programmer.
page 4.26
Publication Reference Chart
GFK-2327
6 Inch QuickPanel View (Basic) Hardware Reference Guide
GFK-2580
6 Inch QuickPanel View (Basic TFT) Hardware Reference Guide
GFK-2325
6 Inch QuickPanel View (Intermediate) Hardware Reference Guide
GFK-2243
6 Inch QuickPanel View (Loaded) Hardware Reference Guide
GFK-2512
8 Inch QuickPanel View Hardware Users Guide
GFK-2306
12 Inch QuickPanel View (Intermediate) Hardware Reference Guide
GFK-2284
12 Inch QuickPanel View (Loaded) Hardware Reference Guide
GFK-2402
15 Inch QuickPanel View (Loaded) Hardware Reference Guide
GFK-2297
Genius I/O Communication Card Hardware Reference Guide
GFK-2270
DeviceNet Master & Slave Communication Card Hardware Reference Guide
GFK-2291
PROFIBUS Slave Communication Card Hardware Reference Guide
GFK-2276
Expanded User Memory Installation Guide
GFK-2368
PCMCIA Adaptor Hardware Reference Guide
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
4.15
QuickPanel View
Operator Interfaces
Operator Interfaces
Available in a variety of display sizes, the QuickPanel View bundled visualization solution
provides the tools required for today’s application needs. By integrating the best-selling
QuickPanel family of touch screens with award-winning Proficy Machine Edition software, QuickPanel View delivers flexible, scalable performance on a rugged hardware
platform. The intuitive environment of Proficy View - Machine Edition software helps
reduce application development time, and connectivity is made easy with a family of
serial, Ethernet and Fieldbus interfaces.
IC754VSB06MTD
IC754VBB06MTD
IC754VSB06CTD
IC754VBB06CTD
Product Name
QuickPanel View Display,
6” Monochrome
Basic
QuickPanel View Display,
6” Monochrome
Basic
QuickPanel View Display,
6” TFT
Basic
QuickPanel View Display,
6” TFT
Basic
Lifecycle Status
Active
Active
Active
Active
Display Size
5.7” (Diagonal)
5.7” (Diagonal)
5.7” (Diagonal)
5.7” (Diagonal)
Display Type
6” Mono
6” Mono
6” TFT
6” TFT
320 x 240 pixels
320 x 240 pixels
320 x 240 pixels
320 x 240 pixels
16 MB
16 MB
16 MB
16 MB
No
No
No
No
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
None
None
None
None
Ethernet: LAN #1
Download Only
Download Only
Download Only
Download Only
Ethernet: LAN #2
None
None
None
None
None
None
None
None
None
None
None
None
Agency Approvals
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
Environmental Rating
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Panel Cut-Out (W x H x D)
6.14” x 4.86” x 2.026”
6.14” x 4.86” x 2.026”
6.14” x 4.86” x 2.026”
6.14” x 4.86” x 2.026”
(156mm x 123.5mm x 51.5mm) (156mm x 123.5mm x 51.5mm) (156mm x 123.5mm x 51.5mm) (156mm x 123.5mm x 51.5mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
12 to 30.0 VDC
12 to 30.0 VDC
12 to 30.0 VDC
12 to 30.0 VDC
Power Consumption
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Operating Temperature
-10 to 60°C (14 to 140°F)
-10 to 60°C (14 to 140°F)
-10 to 60°C (14 to 140°F)
-10 to 60°C (14 to 140°F)
Storage Temperature
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
Operating Humidity
10% to 85% non-condensing
10% to 85% non-condensing
10% to 85% non-condensing
10% to 85% non-condensing
Indicators - LEDs
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
Front of Panel & Depth (W x H x D)
Input Voltage
†Consult
4.16
factory for availability.
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Operator Interfaces
QuickPanel View
Operator Interfaces
Available in a variety of display sizes, the QuickPanel View bundled visualization solution
provides the tools required for today’s application needs. By integrating the best-selling
QuickPanel family of touch screens with award-winning Proficy Machine Edition software, QuickPanel View delivers flexible, scalable performance on a rugged hardware
platform. The intuitive environment of Proficy View - Machine Edition software helps
reduce application development time, and connectivity is made easy with a family of
serial, Ethernet and Fieldbus interfaces.
IC754VSI06MTD
IC754VBI06MTD
IC754VSI06STD
IC754VBI06STD
Product Name
QuickPanel View Display,
6” Monochrome
Intermediate
QuickPanel View Display,
6” Monochrome
Intermediate
QuickPanel View Display,
6” STN-Color
Intermediate
QuickPanel View Display,
6” STN-Color
Intermediate
Lifecycle Status
Active
Active
Active
Active
Display Size
5.7” (Diagonal)
5.7” (Diagonal)
5.7” (Diagonal)
5.7” (Diagonal)
Display Type
6” Mono
6” Mono
6” Color-STN
6” Color-STN
320 x 240 pixels
320 x 240 pixels
320 x 240 pixels
320 x 240 pixels
32 MB
32 MB
32 MB
32 MB
To 96 MB
To 96 MB
To 96 MB
To 96 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
None
None
None
None
Ethernet: LAN #1
10/100 Mbps
10/100 Mbps
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
None
None
None
None
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
One, Type 2
One, Type 2
One, Type 2
One, Type 2
Agency Approvals
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
Environmental Rating
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
Panel Cut-Out (W x H x D)
6.14” x 4.86” x 2.76”
(156mm x 123.5mm x 70mm)
6.14” x 4.86” x 2.76”
(156mm x 123.5mm x 70mm)
6.14” x 4.86” x 2.76”
(156mm x 123.5mm x 70mm)
6.14” x 4.86” x 2.76”
(156mm x 123.5mm x 70mm)
Front of Panel & Depth (W x H x D)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
12 to 30.0 VDC
12 to 30.0 VDC
12 to 30.0 VDC
12 to 30.0 VDC
Power Consumption
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Operating Temperature
-10 to 60°C (14 to 140°F)
-10 to 60°C (14 to 140°F)
0 to 60°C (32 to 140°F)
0 to 60°C (32 to 140°F)
Storage Temperature
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
Operating Humidity
10% to 85% non-condensing
10% to 85% non-condensing
10% to 90% non-condensing
10% to 90% non-condensing
Indicators - LEDs
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Input Voltage
†Consult
factory for availability.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
4.17
QuickPanel View
Operator Interfaces
Operator Interfaces
Available in a variety of display sizes, the QuickPanel View bundled visualization solution
provides the tools required for today’s application needs. By integrating the best-selling
QuickPanel family of touch screens with award-winning Proficy Machine Edition software,
QuickPanel View delivers flexible, scalable performance on a rugged hardware platform.
The intuitive environment of Proficy View - Machine Edition software helps reduce
application development time, and connectivity is made easy with a family of serial,
Ethernet and Fieldbus interfaces.
IC754VSI06SKD
IC754VBI08CTD
IC754VSI12MTD
IC754VBI12MTD
Product Name
QuickPanel View Display,
6” STN-Color
Intermediate with Keypad
QuickPanel View Display,
8” TFT-Color
Intermediate
QuickPanel View Display,
12” Monochrome
Intermediate
QuickPanel View Display,
12” Monochrome
Intermediate
Lifecycle Status
Active
Active
Active
Active
Display Size
5.7” (Diagonal)
8.4” (Diagonal)
12.1” (Diagonal)
12.1” (Diagonal)
Display Type
6” Color-STN
8” Color-TFT
12” Mono
12” Mono
320 x 240 pixels
800 x 600 pixels
800 x 600 pixels
800 x 600 pixels
32 MB
32 MB
32 MB
32 MB
To 96 MB
To 64 MB or 96 MB
To 96 MB
To 96 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
None
None
None
None
Ethernet: LAN #1
10/100 Mbps
10/100 Mbps
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
None
None
None
None
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
One, Type 2
One, Type 2
One, Type 2
One, Type 2
Agency Approvals
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
Environmental Rating
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X, UL50 Type 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
Panel Cut-Out (W x H x D)
11.88” x 8.96” x 2.37”
(302mm x 228mm x 60mm)
8.97” x 7.34” x 3.03”
(228mm x 186mm x 77mm)
11.88” x 8.96” x 2.37”
(302mm x 228mm x 60mm)
11.88” x 8.96” x 2.37”
(302mm x 228mm x 60mm)
Front of Panel & Depth (W x H x D)
13.26” x 10.34” x 0.38”
(337mm x 263mm x 10mm)
9.8” x 8.18” x 0.35”
(249mm x 208mm x 9mm)
13.26” x 10.34” x 0.38”
(337mm x 263mm x 10mm)
13.26” x 10.34” x 0.38”
(337mm x 263mm x 10mm)
12 VDC @ ±20% or
24 VDC @ ±20%
10.8 to 30.0 VDC
12 VDC @ ±20% or
24 VDC @ ±20%
12 VDC @ ±20% or
24 VDC @ ±20%
Less than 24W @ 24 VDC
24W
Less than 48W @ 24 VDC
Less than 48W @ 24 VDC
0 to 50°C (32 to 122°F)
0 to 60°C (32 to 140°F)
0 to 50°C (32 to 122°F)
0 to 50°C (32 to 122°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
Operating Humidity
10% to 85% non-condensing
10% to 90% non-condensing
10% to 85% non-condensing
10% to 85% non-condensing
Indicators - LEDs
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Input Voltage
Power Consumption
Operating Temperature
Storage Temperature
†Consult
4.18
factory for availability.
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Operator Interfaces
QuickPanel View
Operator Interfaces
Available in a variety of display sizes, the QuickPanel View bundled visualization solution
provides the tools required for today’s application needs. By integrating the best-selling
QuickPanel family of touch screens with award-winning Proficy Machine Edition software,
QuickPanel View delivers flexible, scalable performance on a rugged hardware platform.
The intuitive environment of Proficy View - Machine Edition software helps reduce
application development time, and connectivity is made easy with a family of serial,
Ethernet and Fieldbus interfaces.
IC754VSI12CTD
IC754VSI12CTD CA
IC754VBI12CTD
Product Name
QuickPanel View Display,
12” TFT-Color
Intermediate
QuickPanel View Display,
12” TFT-Color Intermediate Conformal Coated
QuickPanel View Display,
12” TFT-Color
Intermediate
Lifecycle Status
Active
Active
Active
Display Size
12.1” (Diagonal)
12.1” (Diagonal)
12.1” (Diagonal)
Display Type
12” Color-TFT
12” Color-TFT
12” Color-TFT
800 x 600 pixels
800 x 600 pixels
800 x 600 pixels
32 MB
32 MB
32 MB
To 96 MB
To 96 MB
To 96 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
None
None
None
Ethernet: LAN #1
10/100 Mbps
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
None
None
None
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
One, Type 2
One, Type 2
One, Type 2
Agency Approvals
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
Environmental Rating
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
Panel Cut-Out (W x H x D)
11.88” x 8.96” x 2.37”
(302mm x 228mm x 60mm)
11.88” x 8.96” x 2.37”
(302mm x 228mm x 60mm)
11.88” x 8.96” x 2.37”
(302mm x 228mm x 60mm)
Front of Panel & Depth (W x H x D)
13.26” x 10.34” x 0.38”
(337mm x 263mm x 10mm)
13.26” x 10.34” x 0.38”
(337mm x 263mm x 10mm)
13.26” x 10.34” x 0.38”
(337mm x 263mm x 10mm)
12 VDC @ ±20% or
24 VDC @ ±20%
12 VDC @ ±20% or
24 VDC @ ±20%
12 VDC @ ±20% or
24 VDC @ ±20%
Less than 48W @ 24 VDC
Less than 48W @ 24 VDC
Less than 48W @ 24 VDC
0 to 50°C (32 to 122°F)
0 to 50°C (32 to 122°F)
0 to 50°C (32 to 122°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
Operating Humidity
10% to 85% non-condensing
10% to 85% non-condensing
10% to 85% non-condensing
Indicators - LEDs
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Input Voltage
Power Consumption
Operating Temperature
Storage Temperature
†Consult
factory for availability.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
4.19
QuickPanel View
Operator Interfaces
Operator Interfaces
Available in a variety of display sizes, the QuickPanel View bundled visualization solution provides
the tools required for today’s application needs. By integrating the best-selling QuickPanel family
of touch screens with award-winning Proficy Machine Edition software, QuickPanel View delivers
flexible, scalable performance on a rugged hardware platform. The intuitive environment of Proficy
View - Machine Edition software helps reduce application development time, and connectivity is
made easy with a family of serial, Ethernet and Fieldbus interfaces. Full-featured QuickPanel View
modules take Operator Interface products to an entirely new level of openness. A built-in web
­server provides access to data and graphics using any standard browser.
IC754VSL06MTD
IC754VBL06MTD
IC754VSL06CTD
IC754VBL06CTD
Product Name
QuickPanel View Display,
6” Mono Loaded
QuickPanel View Display,
6” Mono Loaded
QuickPanel View Display,
6” TFT-Color Loaded
QuickPanel View Display,
6” TFT-Color Loaded
Lifecycle Status
Active
Active
Active
Active
Display Size
5.7” (Diagonal)
5.7” (Diagonal)
5.7” (Diagonal)
5.7” (Diagonal)
Display Type
6” Mono
6” Mono
6” Color-TFT
6” Color-TFT
320 x 240 pixels
320 x 240 pixels
320 x 240 pixels
320 x 240 pixels
32 MB
32 MB
32 MB
32 MB
To 96 MB
To 96 MB
To 96 MB
To 96 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
RS232
RS232
RS232
RS232
Ethernet: LAN #1
10/100 Mbps
10/100 Mbps
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
None
None
None
None
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
One, Type 2
One, Type 2
One, Type 2
One, Type 2
Agency Approvals
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
Environmental Rating
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
Panel Cut-Out (W x H x D)
6.14” x 4.86” x 2.76”
(156mm x 123.5mm x 70mm)
6.14” x 4.86” x 2.76”
(156mm x 123.5mm x 70mm)
6.14” x 4.86” x 2.76”
(156mm x 123.5mm x 70mm)
6.14” x 4.86” x 2.76”
(156mm x 123.5mm x 70mm)
Front of Panel & Depth (W x H x D)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
12 to 30.0 VDC
12 to 30.0 VDC
12 to 30.0 VDC
12 to 30.0 VDC
Power Consumption
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Operating Temperature
-10 to 60°C (14 to 140°F)
-10 to 60°C (14 to 140°F)
-10 to 60°C (14 to 140°F)
-10 to 60°C (14 to 140°F)
Storage Temperature
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
Operating Humidity
10% to 85% non-condensing
10% to 85% non-condensing
5% to 90% non-condensing
5% to 90% non-condensing
Indicators - LEDs
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Input Voltage
†Consult
4.20
factory for availability.
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Operator Interfaces
QuickPanel View
Operator Interfaces
Available in a variety of display sizes, the QuickPanel View bundled visualization solution provides
the tools required for today’s application needs. By integrating the best-selling QuickPanel family
of touch screens with award-winning Proficy Machine Edition software, QuickPanel View delivers
flexible, scalable performance on a rugged hardware platform. The intuitive environment of Proficy
View - Machine Edition software helps reduce application development time, and connectivity is
made easy with a family of serial, Ethernet and Fieldbus interfaces. Full-featured QuickPanel View
modules take Operator Interface products to an entirely new level of openness. A built-in web
­server provides access to data and graphics using any standard browser.
IC754VBL06CTDCA
IC754VBF08CTD
IC754VSF12CTD
IC754VBF12CTD
Product Name
QuickPanel View Display,
6” TFT-Color Loaded Conformal coated
QuickPanel View Display,
8” TFT-Color Loaded
QuickPanel View Display,
12” TFT-Color Loaded
QuickPanel View Display,
12” TFT-Color Loaded
Lifecycle Status
Active
Active
Active
Active
Display Size
5.7” (Diagonal)
8.4” (Diagonal)
12.1” (Diagonal)
12.1” (Diagonal)
Display Type
6” Color-TFT
8” Color-TFT
12” Color-TFT
12” Color-TFT
320 x 240 pixels
800 x 600 pixels
800 x 600 pixels
800 x 600 pixels
32 MB
64 MB
64 MB
64 MB
To 96 MB
To 96 MB or 128 MB
To 96 MB or 128 MB
To 96 MB or 128 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
RS232
RS232
RS232
RS232
Ethernet: LAN #1
10/100 Mbps
10/100 Mbps
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
None
None
10/100 Mbps
10/100 Mbps
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
One, Type 2
One, Type 2
One, Type 2
One, Type 2
Agency Approvals
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
Environmental Rating
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X, UL50 Type 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
Panel Cut-Out (W x H x D)
6.14” x 4.86” x 2.76”
(156mm x 123.5mm x 70mm)
6.14” x 4.86” x 2.76”
(156mm x 123.5mm x 70mm)
11.88” x 8.96” x 2.37”
(302mm x 228mm x 60mm)
11.88” x 8.96” x 2.37”
(302mm x 228mm x 60mm)
Front of Panel & Depth (W x H x D)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
9.8” x 8.18” x 0.35”
(249mm x 208mm x 9mm)
13.26” x 10.34” x 0.38”
(337mm x 263mm x 10mm)
13.26” x 10.34” x 0.38”
(337mm x 263mm x 10mm)
12 to 30.0 VDC
10.8 to 30.0 VDC
12 VDC @ ±20% or
24 VDC @ ±20%
12 VDC @ ±20% or
24 VDC @ ±20%
Power Consumption
Less than 24W @ 24 VDC
24W
Less than 48W @ 24 VDC
Less than 48W @ 24 VDC
Operating Temperature
-10 to 60°C (14 to 140°F)
0 to 60°C (32 to 140°F)
0 to 50°C (32 to 122°F)
0 to 50°C (32 to 122°F)
Storage Temperature
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
Operating Humidity
5% to 90% non-condensing
10% to 85% non-condensing
10% to 85% non-condensing
10% to 85% non-condensing
Indicators - LEDs
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Input Voltage
†Consult
factory for availability.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
4.21
QuickPanel View
Operator Interfaces
Operator Interfaces
Available in a variety of display sizes, the QuickPanel View bundled visualization solution provides
the tools required for today’s application needs. By integrating the best-selling QuickPanel family
of touch screens with award-winning Proficy Machine Edition software, QuickPanel View delivers
flexible, scalable performance on a rugged hardware platform. The intuitive environment of Proficy
View - Machine Edition software helps reduce application development time, and connectivity is
made easy with a family of serial, Ethernet and Fieldbus interfaces. Full-featured QuickPanel View
modules take Operator Interface products to an entirely new level of openness. A built-in web
­server provides access to data and graphics using any standard browser.
IC754VBF12CTDCA
IC754VSF15CTD
IC754VBF15CTD
IC754VBF15CTDCA
Product Name
QuickPanel View Display,
12” TFT-Color Loaded Conformal Coated
QuickPanel View Display,
15” TFT-Color Loaded
QuickPanel View Display,
15” TFT-Color Loaded
QuickPanel View Display,
15” TFT-Color Loaded Conformal coated
Lifecycle Status
Active
Active
Active
Active
Display Size
12.1” (Diagonal)
15.1” (Diagonal)
15.1” (Diagonal)
15.1” (Diagonal)
Display Type
12” Color-TFT
15” Color-TFT
15” Color-TFT
15” Color-TFT
800 x 600 pixels
1024 x 768 pixels
1024 x 768 pixels
1024 x 768 pixels
32 MB
64 MB
64 MB
64 MB
To 96 MB
128 MB
128 MB
128 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
RS232
RS232
RS232
RS232
Ethernet: LAN #1
10/100 Mbps
10/100 Mbps
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
10 Mbps
10/100 Mbps
10/100 Mbps
10/100 Mbps
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
One, Type 2
One, Type 2
One, Type 2
One, Type 2
Agency Approvals
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
Environmental Rating
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
Panel Cut-Out (W x H x D)
11.88” x 8.96” x 2.37”
(302mm x 228mm x 60mm)
14.93” x 12.03” x 2.78”
(379mm x 305mm x 71mm)
14.93” x 12.03” x 2.78”
(379mm x 305mm x 71mm)
14.93” x 12.03” x 2.78”
(379mm x 305mm x 71mm)
Front of Panel & Depth (W x H x D)
13.26” x 10.34” x 0.38”
(337mm x 263mm x 10mm)
15.70” x 12.73” x 0.40”
(399mm x 323mm x 10mm)
15.70” x 12.73” x 0.40”
(399mm x 323mm x 10mm)
15.70” x 12.73” x 0.40”
(399mm x 323mm x 10mm)
12 VDC @ ±20% or
24 VDC @ ±20%
12 VDC @ ±20% or
24 VDC @ ±20%
12 VDC @ ±20% or
24 VDC @ ±20%
12 VDC @ ±20% or
24 VDC @ ±20%
Less than 48W @ 24 VDC
Less than 60W @ 24 VDC
Less than 60W @ 24 VDC
Less than 60W @ 24 VDC
0 to 50°C (32 to 122°F)
0 to 50°C (32 to 122°F)
0 to 50°C (32 to 122°F)
0 to 50°C (32 to 122°F)
-20 to 70°C (-4 to 158°F)
-20 to 60°C (-4 to 140°F)
-20 to 60°C (-4 to 140°F)
-20 to 60°C (-4 to 140°F)
Operating Humidity
10% to 85% non-condensing
10% to 85% non-condensing
10% to 85% non-condensing
10% to 85% non-condensing
Indicators - LEDs
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Input Voltage
Power Consumption
Operating Temperature
Storage Temperature
†Consult
4.22
factory for availability.
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Operator Interfaces
QuickPanel View
Starter Kits
Available in a variety of display sizes, the QuickPanel View bundled visualization solution
provides the tools required for today’s application needs. By integrating the best-selling
QuickPanel family of touch screens with award-winning Proficy Machine Edition software,
QuickPanel View delivers flexible, scalable performance on a rugged hardware platform.
The intuitive environment of Proficy View - Machine Edition software helps reduce application development time, and connectivity is made easy with a family of serial, Ethernet and
Fieldbus interfaces.
IC754VKB06MTD
IC754VKI06MTD
IC754VKI06STD
Product Name
QuickPanel View Starter Kit,
includes 6” Monochrome
Basic Display,
Proficy ME Development Software,
Ethernet Cable and
Power Supply
QuickPanel View Starter Kit,
includes 6” Monochrome
Intermediate Display,
Proficy ME Development Software,
Ethernet Cable and
Power Supply
QuickPanel View Starter Kit,
includes 6” STN-Color
Intermediate Display,
Proficy ME Development Software,
Ethernet Cable and
Power Supply
Lifecycle Status
Active
Active
Active
Display Size
5.7” (Diagonal)
5.7” (Diagonal)
5.7” (Diagonal)
Display Type
6” Mono
6” Mono
6” Color-STN
320 x 240 pixels
320 x 240 pixels
320 x 240 pixels
16 MB
32 MB
32 MB
No
To 96 MB
To 96 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
None
None
None
Ethernet: LAN #1
Download Only
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
None
None
None
None
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
None
One, Type 2
One, Type 2
Agency Approvals
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
Environmental Rating
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
6.14” x 4.86” x 2.03”
(158mm x 126mm x 52mm)
6.14” x 4.86” x 2.76”
(156mm x 123.5mm x 70mm)
6.14” x 4.86” x 2.76”
(156mm x 123.5mm x 70mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
10.8 to 30.0 VDC
10.8 to 30.0 VDC
10.8 to 30.0 VDC
Power Consumption
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Operating Temperature
-10 to 60°C (14 to 140°F)
-10 to 60°C (14 to 140°F)
0 to 60°C (32 to 140°F)
Storage Temperature
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
Operating Humidity
10% to 85% non-condensing
10% to 85% non-condensing
10% to 90% non-condensing
Indicators - LEDs
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Panel Cut-Out (W x H x D)
Front of Panel & Depth (W x H x D)
Input Voltage
†Consult
factory for availability.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
4.23
QuickPanel View
Operator Interfaces
Starter Kits
Available in a variety of display sizes, the QuickPanel View bundled visualization solution
provides the tools required for today’s application needs. By integrating the best-selling
QuickPanel family of touch screens with award-winning Proficy Machine Edition software,
QuickPanel View delivers flexible, scalable performance on a rugged hardware platform.
The intuitive environment of Proficy View - Machine Edition software helps reduce application development time, and connectivity is made easy with a family of serial, Ethernet and
Fieldbus interfaces.
IC754VKI06SKD
IC754VKI12MTD
IC754VKI12CTD
QuickPanel View Starter Kit,
includes 6” STN-Color
Intermediate Display
with Keypad
QuickPanel View Starter Kit,
includes 12” Monochrome
Intermediate Display,
Proficy ME Development Software,
Ethernet Cable and
Power Supply
QuickPanel View Starter Kit,
includes 12” TFT-Color
Intermediate Display,
Proficy ME Development Software,
Ethernet Cable and
Power Supply
Active
Active
Active
Display Size
5.7” (Diagonal)
12.1” (Diagonal)
12.1” (Diagonal)
Display Type
6” Color-STN
12” Mono
12” Color-TFT
320 x 240 pixels
800 x 600 pixels
800 x 600 pixels
32 MB
32 MB
32 MB
Product Name
Lifecycle Status
Resolution
Memory: DRAM
Memory: Expandable
To 96 MB
To 96 MB
To 96 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
None
None
None
Ethernet: LAN #1
10/100 Mbps
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
None
None
None
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
Communication Expansion
Compact Flash
One, Type 2
One, Type 2
One, Type 2
Agency Approvals
UL - Class 1 Div 2 (A, B, C, D),
ATEX - Class 1 Zone 2,
CE Mark
UL - Class 1 Div 2 (A, B, C, D),
ATEX - Class 1 Zone 2,
CE Mark
UL - Class 1 Div 2 (A, B, C, D),
ATEX - Class 1 Zone 2,
CE Mark
Environmental Rating
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
Panel Cut-Out (W x H x D)
11.88” x 8.96” x 2.37”
(302mm x 228mm x 60mm)
11.88” x 8.96” x 2.37”
(302mm x 228mm x 60mm)
11.88” x 8.96” x 2.37”
(302mm x 228mm x 60mm)
Front of Panel & Depth (W x H x D)
13.26” x 10.34” x 0.38”
(337mm x 263mm x 10mm)
13.26” x 10.34” x 0.38”
(337mm x 263mm x 10mm)
13.26” x 10.34” x 0.38”
(337mm x 263mm x 10mm)
12 VDC @ ±20% or
24 VDC @ ±20%
12 VDC @ ±20% or
24 VDC @ ±20%
12 VDC @ ±20% or
24 VDC @ ±20%
Less than 24W @ 24 VDC
Less than 48W @ 24 VDC
Less than 48W @ 24 VDC
0 to 60°C (32 to 140°F)
0 to 50°C (32 to 122°F)
0 to 50°C (32 to 122°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
Operating Humidity
10% to 90% non-condensing
10% to 90% non-condensing
10% to 90% non-condensing
Indicators - LEDs
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
Input Voltage
Power Consumption
Operating Temperature
Storage Temperature
†Consult
4.24
factory for availability.
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Operator Interfaces
QuickPanel View
Starter Kits
Available in a variety of display sizes, the QuickPanel View bundled visualization solution provides
the tools required for today’s application needs. By integrating the best-selling QuickPanel family
of touch screens with award-winning Proficy Machine Edition software, QuickPanel View delivers
flexible, scalable performance on a rugged hardware platform. The intuitive environment of Proficy
View - Machine Edition software helps reduce application development time, and connectivity is
made easy with a family of serial, Ethernet and Fieldbus interfaces. Full-featured QuickPanel View
modules take Operator Interface products to an entirely new level of openness. A built-in web
­server provides access to data and graphics using any standard browser.
IC754VKL06MTD
IC754VKL06CTD
IC754VKF12CTD
IC754VKF15CTD
Product Name
QuickPanel View Starter Kit,
includes 6” Mono
Loaded Display,
Proficy ME Development
Software, Ethernet Cable
and Power Supply
QuickPanel View Starter Kit,
includes 6” TFT-Color
Loaded Display,
Proficy ME Development
Software, Ethernet Cable
and Power Supply
QuickPanel View Starter Kit,
includes 12” TFT-Color
Loaded Display,
Proficy ME Development
Software, Ethernet Cable
and Power Supply
QuickPanel View Starter Kit,
includes 15” TFT-Color
Loaded Display,
Proficy ME Development
Software, Ethernet Cable
and Power Supply
Lifecycle Status
Active
Active
Active
Active
Display Size
5.7” (Diagonal)
5.7” (Diagonal)
12.1” (Diagonal)
15.1” (Diagonal)
Display Type
6” Mono
6” Color-TFT
12” Color-TFT
15” Color-TFT
320 x 240 pixels
320 x 240 pixels
800 x 600 pixels
1024 x 768 pixels
32 MB
32 MB
32 MB
64 MB
To 96 MB
To 96 MB
To 96 MB
128 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
RS232
RS232
RS232
RS232
Ethernet: LAN #1
10/100 Mbps
10/100 Mbps
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
None
None
10 Mbps
10/100 Mbps
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
One, Type 2
One, Type 2
One, Type 2
One, Type 2
Agency Approvals
UL - Class 1 Div 2 (A, B, C, D),
ATEX - Class 1 Zone 2,
CE Mark
UL - Class 1 Div 2 (A, B, C, D),
ATEX - Class 1 Zone 2,
CE Mark
UL - Class 1 Div 2 (A, B, C, D),
ATEX - Class 1 Zone 2,
CE Mark
UL - Class 1 Div 2 (A, B, C, D),
ATEX - Class 1 Zone 2,
CE Mark
Environmental Rating
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
Panel Cut-Out (W x H x D)
6.14” x 4.86” x 2.76”
(156mm x 123.5mm x 70mm)
6.14” x 4.86” x 2.76”
(156mm x 123.5mm x 70mm)
11.88” x 8.96” x 2.37”
(302mm x 228mm x 60mm)
14.93” x 12.03” x 2.78”
(379mm x 305mm x 71mm)
Front of Panel & Depth (W x H x D)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
8.00” x 6.17” x 0.85”
(203mm x 157mm x 21.5mm)
13.26” x 10.34” x 0.38”
(337mm x 263mm x 10mm)
15.70” x 12.73” x 0.40”
(399mm x 323mm x 10mm)
10.8 to 30.0 VDC
10.8 to 30.0 VDC
12 VDC @ ±20% or
24 VDC @ ±20%
12 VDC @ ±20% or
24 VDC @ ±20%
Power Consumption
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Less than 48W @ 24 VDC
Less than 60W @ 24 VDC
Operating Temperature
-10 to 60°C (14 to 140°F)
0 to 60°C (32 to 140°F)
0 to 50°C (32 to 122°F)
0 to 50°C (32 to 122°F)
Storage Temperature
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 60°C (-4 to 140°F)
Operating Humidity
10% to 90% non-condensing
10% to 90% non-condensing
10% to 90% non-condensing
10% to 90% non-condensing
Indicators - LEDs
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
Input Voltage
†Consult
factory for availability.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
4.25
QuickPanel View
Operator Interfaces
QuickPanel View Communication Hardware
PLC Manufacturer
PLC Type
Part Number
Description
Lifecycle Status
Allen Bradley
SLC500, 5/01, 5/02, 5/03
HMI-CAB-C83
DH-485 Program Port, 8-pin RJ-45Male, RS-422,
No simultaneous connection to program port
Active
HMI-CAB-C84
DH-485 Program Port, 8-pin RJ-45 Male, RS-422,
with simultaneous connection to program port
Active
SLC5/03, 5/04, ControlLogix
HMI-CAB-C52
Channel 0, 9-pin Female, RS-232
Active
PLC-5
HMI-CAB-C51
KF2 Module, 25-pin Female, RS-232
Active
HMI-CAB-C53
Channel 0, 25-pin Male, RS-232
Active
HMI-CAB-C55
KE Module, 15-pin Male, RS-232
Active
HMI-CAB-C107
DF1, 25-pin Male, RS-422
Active
MicroLogix
HMI-CAB-C106
DF1, 8-pin Circular DIN, RS-232
Active
Data Highway Plus
IC754ABD001
Data Highway Plus communication card for QuickPanel View†
Active
DL205 & DL305
HMI-CAB-C86
Programming Port, 6-pin Modular Male, RS-232
Active
DL305 & DL405
HMI-CAB-C103
Programming Port, 4-pin Modular Male, RS-232
Mature
DL305 & DL405 w/ 25-pin comm. port
HMI-CAB-C53
Programming Port, 25-pin Male, RS-232
Active
DeviceNet
IC754DVNS01
DeviceNet Slave Communication Card for QuickPanel View
Active
PROFIBUS
IC754PBSS01
PROFIBUS Slave Communication Card for QuickPanel View
Active
Series 90 CMM Module
HMI-CAB-C53
25-pin Male, RS-232
Active
HMI-CAB-C93
25-pin Male, RS-422
Active
Series 90-30 & 90-70
HMI-CAB-C82
Programming Port, 15-pin Male, RS-422
Active
Series 90-30 CPU351, 352, 363
HMI-CAB-C120
Program Port, 6-pin Male RJ-11, RS-232
Active
VersaMax CPU001, 002, 005
HMI-CAB-C111
Program Port, 9-pin Male, RS-232
Active
VersaMax Nano/Micro
HMI-CAB-C119
Program Port, 8-pin Male RJ-45, RS-232
Active
Genius
IC754GEN001
Genius Communication Card for QuickPanel View & Control
Active
Series A
HMI-CAB-C53
25-pin Male, RS-232
Active
HMI-CAB-C88
9-pin Male, RS-232
Active
Series FX
HMI-CAB-C91
25-pin Male, RS-422
Active
984 A, B, X
HMI-CAB-C53
25-pin Male, RS-232
Active
984 Slot and Compact
HMI-CAB-C58
9-pin Male, RS-232
Active
984 Micro
HMI-CAB-C102
Program Port, 8-pin Male RJ-45, RS-232
Active
C200H
HMI-CAB-C53
25-pin Male, RS-232
Active
HMI-CAB-C108
9-pin Male, RS-422
Active
C20H, CQM1
HMI-CAB-C67
9-pin Male, RS-232
Active
500 Series
HMI-CAB-C53
Programming Port, 25-pin Male, RS-232
Active
HMI-CAB-C101
Programming Port, 9-pin Female, RS-232
Mature
HMI-CAB-C92
9-pin Male, RS-422
Mature
TI545-1102
HMI-CAB-C100
Programming Port, 9-pin Female, RS-422
Active
305 & 405
HMI-CAB-C53
Programming Port, 25-pin Male, RS-232
Active
S7-200 PPI
HMI-CAB-C110
9-pin Male, RS-422
Active
SY/MAX Model 100 & greater
HMI-CAB-C94
9-pin Male, RS-422
Active
SY/MAX Model 50 via link adaptor
HMI-CAB-C53
25-pin Male, RS-232
Active
Automation Direct
Fieldbus
GE
Mitsubishi
Modicon
Omron
Siemens
Square D SY/MAX
Accessories
Part Number
Description
IC754PCMCIA001
PCMCIA Adaptor for QuickPanel View
IC754ACC32MEM
Expansion Memory 32 Mbytes
IC754ACC64MEM
Expansion Memory 64 Mbytes
IC754ACC06GAS
Gasket for 6 Inch QuickPanel View
IC754ACC12GAS
Gasket for 12 Inch QuickPanel View
IC754ACC15GAS
Gasket for 15 Inch QuickPanel View
IC754ACC06MNT
Mounting Clips & Power Connector for 6 Inch QuickPanel View
IC754ACC12MNT
Mounting Clips & Power Connector for 12 Inch QuickPanel View
IC754ACC15MNT
Mounting Clips & Power Connector for 15 Inch QuickPanel View
IC754ACC06BEZ01
Stainless Steel Bezel for 6 Inch Mono & TFT-Color QuickPanel View
IC754ACC06BEZ02
Stainless Steel Bezel for 6 Inch STN-Color QuickPanel View
IC754ACC12BEZ01
Stainless Steel Bezel for 12 Inch TFT-Color QuickPanel View
IC754BEZ06GAS
Replacement Gasket for 6 Inch Stainless Steel Bezel
IC754BEZ12GAS
Replacement Gasket for 12 Inch Stainless Steel Bezel
IC754ACC12ADP
Adaptor Kit for 12 Inch QuickPanel View into CEIIx Cut-out
Adaptor Kit for 8 Inch QuickPanel View into 9" panel
IC754ACC08ADP
†Consult factory for availability.
4.26
GE Intelligent Platforms Control Systems Solutions
Lifecycle Status
Active
Active
Active
Active
Active
Active
Active
Active
Active
Active
Active
Active
Active
Active
Active
Active
www.ge-ip.com
Operator Interfaces
QuickPanel View - Europe, Middle East and Africa
QuickPanel View-Europe, Middle East and Africa
GE Intelligent Platforms markets and
sells QuickPanel View products that
are designed to meet the market
needs of companies in Europe, the
Middle East and Africa.
QuickPanel View bundled visualization
solution provides the tools required for
today’s application needs. By integrating the QuickPanel family of touch
screens with Proficy Machine Edition
software, QuickPanel View delivers
flexible, scalable performance on a
rugged hardware platform. The intuitive environment of Proficy View –
Machine Edition software helps reduce
application development time, and
connectivity is made easy with a
­family of serial, Ethernet and Fieldbus interfaces.
Operator Interfaces
Features include:
• Display sizes from 6” to 15”
• Choice of Monochrome, Color-STN,
or Color-TFT display
• Microsoft Windows® CE operating
system
• Expandable memory and Fieldbus
cards†
• CompactFlash†
• Functions from data collection
and trending to system security
and alarming
• Built-in web server for access
to data, and panels using any
standard browser†
• Communication over serial,
Ethernet, and communication
expansion cards†
• Multi-language support selectable
by the operator when the system
is online
• Shared tags for increased
productivity – applications ­developed
for QuickPanel View can share tags
with other Proficy Machine Edition
applications, eliminating the need to
enter the data more than once
• Migration of applications developed
with QuickDesigner
• Extensive library of pre-configured
animation objects
• UL Class 1 Div 2 (A, B, C, D), ATEX
Class 1, Zone 2, CE Mark, DNV†
†
Available on select models. See following pages for availability.
Proficy Machine Edition
Proficy Machine Edition is an
advanced software environment for
the development and maintenance
of machine level automation.
Visualization, motion control and
­execution logic are developed with
a single programmer.
pages 4.28-4.32
Communication Hardware
and Accessories
page 4.33
Publication Reference Chart
GFK-2328
6 Inch QuickPanel View (Euro-Basic) Hardware Reference Guide
GFK-2580
6 Inch QuickPanel View (Basic TFT) Hardware Reference Guide
GFK-2326
6 Inch QuickPanel View (Euro-Intermediate) Hardware Reference Guide
GFK-2305
6 Inch QuickPanel View (Euro-Loaded) Hardware Reference Guide
GFK-2512
8 Inch QuickPanel View Hardware Users Guide
GFK-2306
12 Inch QuickPanel View (Intermediate) Hardware Reference Guide
GFK-2284
12 Inch QuickPanel View (Loaded) Hardware Reference Guide
GFK-2402
15 Inch QuickPanel View (Loaded) Hardware Reference Guide
GFK-2297
Genius I/O Communication Card Hardware Reference Guide
GFK-2270
DeviceNet Master & Slave Communication Card Hardware Reference Guide
GFK-2291
PROFIBUS Slave Communication Card Hardware Reference Guide
GFK-2276
Expanded User Memory Installation Guide
GFK-2368
PCMCIA Adaptor Hardware Reference Guide
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
4.27
QuickPanel View - Europe, Middle East and Africa
Operator Interfaces
Operator Interfaces
Available in a variety of display sizes, the QuickPanel View bundled visualization solution
provides the tools required for today’s application needs. By integrating the best-selling
QuickPanel family of touch screens with award-winning Proficy Machine Edition software, QuickPanel View delivers flexible, scalable performance on a rugged hardware
platform. The intuitive environment of Proficy View - Machine Edition software helps
reduce application development time, and connectivity is made easy with a family of
serial, Ethernet and Fieldbus interfaces.
IC754VGB06MTD
IC754VHB06MTD
IC754VGB06CTD
IC754VGI06MTD
Product Name
QuickPanel View Display,
6” Monochrome
Basic
QuickPanel View Display,
6” Monochrome
Basic
QuickPanel View Display,
6” TFT
Basic
QuickPanel View Display,
6” Monochrome
Intermediate
Lifecycle Status
Active
Active
Active
Active
Display Size
5.7 Inch (Diagonal)
5.7 Inch (Diagonal)
5.7 Inch (Diagonal)
5.7 Inch (Diagonal)
Display Type
Monochrome
Monochrome
6” TFT
Monochrome
320 x 240 pixels
320 x 240 pixels
320 x 240 pixels
320 x 240 pixels
16 MB
16 MB
16 MB
32 MB
No
No
No
To 96 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
None
None
None
None
Ethernet: LAN #1
Download only
Download only
Download only
10/100 Mbps
Ethernet: LAN #2
None
None
None
None
None
None
None
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
None
None
None
One, Type 2
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Agency Approval
UL/cUL - Class 1 Div 2 (A, B, C, D) UL/cUL - Class 1 Div 2 (A, B, C, D) UL/cUL - Class 1 Div 2 (A, B, C, D) UL/cUL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
ATEX - Class 1 Zone 2
ATEX - Class 1 Zone 2
ATEX - Class 1 Zone 2
CE Mark
CE Mark
CE Mark
CE Mark
Environmental Rating
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
Panel Cut Out (W x H x D)
156mm x 123.5mm x 51.5mm
(6.14” x 4.86” x 2.026”) or
200mm x 155mm x 66mm
(7.95” x 6.12” x 2.60”)
156mm x 123.5mm x 51.5mm
(6.14” x 4.86” x 2.026”) or
200mm x 155mm x 66mm
(7.95” x 6.12” x 2.60”)
156mm x 123.5mm x 51.5mm
(6.14” x 4.86” x 2.026”) or
200mm x 155mm x 66mm
(7.95” x 6.12” x 2.60”)
156mm x 123.5mm x 51.5mm
(6.14” x 4.86” x 2.026”) or
200mm x 155mm x 85mm
(7.95” x 6.12” x 3.33”)
216mm x 170mm x 29mm
(8.50” x 6.68” x 1.13”) or
216mm x 170mm x 7mm
(8.50” x 6.68” x 0.28”)
216mm x 170mm x 29mm
(8.50” x 6.68” x 1.13”) or
216mm x 170mm x 7mm
(8.50” x 6.68” x 0.28”)
216mm x 170mm x 29mm
(8.50” x 6.68” x 1.13”) or
216mm x 170mm x 7mm
(8.50” x 6.68” x 0.28”)
216mm x 170mm x 29mm
(8.50” x 6.68” x 1.13”) or
216mm x 170mm x 7mm
(8.50” x 6.68” x 0.28”)
12 to 30.0 VDC
12 to 30.0 VDC
12 to 30.0 VDC
12 to 30.0 VDC
Power Consumption
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Operating Temperature
-10 to 60°C (14 to 140°F)
-10 to 60°C (14 to 140°F)
-10 to 60°C (14 to 140°F)
-10 to 60°C (14 to 140°F)
Storage Temperature
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
Operating Humidity
10% to 85% non-condensing
10% to 85% non-condensing
10% to 85% non-condensing
10% to 85% non-condensing
Indicators - LEDs
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
Bezel Dimensions and Depth
(W x H x D)
Input Voltage
†Consult
4.28
factory for availability.
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Operator Interfaces
QuickPanel View - Europe, Middle East and Africa
Operator Interfaces
Available in a variety of display sizes, the QuickPanel View bundled visualization solution
provides the tools required for today’s application needs. By integrating the best-selling
QuickPanel family of touch screens with award-winning Proficy Machine Edition software, QuickPanel View delivers flexible, scalable performance on a rugged hardware
platform. The intuitive environment of Proficy View - Machine Edition software helps
reduce application development time, and connectivity is made easy with a family of
serial, Ethernet and Fieldbus interfaces.
IC754VHI06MTD
IC754VGI06STD
IC754VHI06STD
IC754VGI06SKD
Product Name
QuickPanel View Display,
6” Monochrome
Intermediate
QuickPanel View Display,
6” STN-Color
Intermediate
QuickPanel View Display,
6” STN-Color
Intermediate
QuickPanel View Display,
6” STN-Color
Intermediate with Keypad
Lifecycle Status
Active
Active
Active
Active
Display Size
5.7 Inch (Diagonal)
5.7 Inch (Diagonal)
5.7 Inch (Diagonal)
5.7 Inch (Diagonal)
Display Type
Monochrome
STN
STN
STN
320 x 240 pixels
320 x 240 pixels
320 x 240 pixels
320 x 240 pixels
32 MB
32 MB
32 MB
32 MB
To 96 MB
To 96 MB
To 96 MB
To 96 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
N/A
N/A
N/A
N/A
Ethernet: LAN #1
10/100 Mbps
10/100 Mbps
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
N/A
N/A
N/A
N/A
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
One, Type 2
One, Type 2
One, Type 2
One, Type 2
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Agency Approval
UL/cUL - Class 1 Div 2 (A, B, C, D) UL/cUL - Class 1 Div 2 (A, B, C, D) UL/cUL - Class 1 Div 2 (A, B, C, D) UL/cUL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
ATEX - Class 1 Zone 2
ATEX Class 1 Zone 2
ATEX Class 1 Zone 2
CE Mark
CE Mark
CE Mark
CE Mark
Environmental Rating
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
Panel Cut Out (W x H x D)
156mm x 123.5mm x 70mm
(6.14” x 4.86” x 2.76”) or
200mm x 155mm x 85mm
(7.95” x 6.12” x 3.33”)
156mm x 123.5mm x 70mm
(6.14” x 4.86” x 2.76”) or
200mm x 155mm x 85mm
(7.95” x 6.12” x 3.33”)
156mm x 123.5mm x 70mm
(6.14” x 4.86” x 2.76”) or
200mm x 155mm x 85mm
(7.95” x 6.12” x 3.33”)
302mm x 228mm x 60mm
(11.88” x 8.96” x 2.37”)
216mm x 170mm x 29mm
(8.50” x 6.68” x 1.13”) or
216mm x 170mm x 7mm
(8.50” x 6.68” x 0.28”)
216mm x 170mm x 29mm
(8.50” x 6.68” x 1.13”) or
216mm x 170mm x 7mm
(8.50” x 6.68” x 0.28”)
216mm x 170mm x 29mm
(8.50” x 6.68” x 1.13”) or
216mm x 170mm x 7mm
(8.50” x 6.68” x 0.28”)
337mm x 263mm x 10mm
(13.26” x 10.34” x 0.38”)
12 to 30.0 VDC
12 to 30.0 VDC
12 to 30.0 VDC
12 VDC @ ±20% or
24 VDC @ ±20%
Power Consumption
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Operating Temperature
-10 to 60°C (14 to 140°F)
0 to 60°C (32 to 140°F)
0 to 60°C (32 to 140°F)
0 to 50°C (32 to 122°F)
Storage Temperature
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
Operating Humidity
10% to 85% non-condensing
10% to 90% non-condensing
10% to 90% non-condensing
10% to 85% non-condensing
Indicators - LEDs
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
Bezel Dimensions and Depth
(W x H x D)
Input Voltage
†Consult
factory for availability.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
4.29
QuickPanel View - Europe, Middle East and Africa
Operator Interfaces
Operator Interfaces
Available in a variety of display sizes, the QuickPanel View bundled visualization solution
provides the tools required for today’s application needs. By integrating the best-selling
QuickPanel family of touch screens with award-winning Proficy Machine Edition software, QuickPanel View delivers flexible, scalable performance on a rugged hardware
platform. The intuitive environment of Proficy View - Machine Edition software helps
reduce application development time, and connectivity is made easy with a family of
serial, Ethernet and Fieldbus interfaces.
IC754VGI08CTD
IC754VGI12MTD
IC754VGI12CTD
Product Name
QuickPanel View Display,
8” TFT-Color
Intermediate
QuickPanel View Display,
12” Monochrome
Intermediate
QuickPanel View Display,
12” TFT-Color
Intermediate
Lifecycle Status
Active
Active
Active
Display Size
8.5” (Diagonal)
12.1 Inch (Diagonal)
12.1 Inch (Diagonal)
Display Type
TFT
Monochrome
TFT
800 x 600 pixels
800 x 600 pixels
800 x 600 pixels
32 MB
32 MB
32 MB
To 64 MB or 96 MB
To 96 MB
To 96 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
N/A
N/A
N/A
Ethernet: LAN #1
10/100 Mbps
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
N/A
N/A
N/A
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
One, Type 2
One, Type 2
One, Type 2
Agency Approval
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL/cUL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL/cUL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
Environmental Rating
NEMA 4/4X, UL50 Type 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
228mm x 186mm x 77mm
(8.97” x 7.34” x 3.03”)
302mm x 228mm x 60mm
(11.88” x 8.96” x 2.37”)
302mm x 228mm x 60mm
(11.88” x 8.96” x 2.37”)
249mm x 208mm x 9mm
(9.8” x 8.18” x 0.35”)
337mm x 263mm x 10mm
(13.26” x 10.34” x 0.38”)
337mm x 263mm x 10mm
(13.26” x 10.34” x 0.38”)
10.8 to 30.0 VDC
12 VDC @ ±20% or
24 VDC @ ±20%
12 VDC @ ±20% or
24 VDC @ ±20%
24W
Less than 48W @ 24 VDC
Less than 48W @ 24 VDC
0 to 60°C (32 to 140°F)
0 to 50°C (32 to 122°F)
0 to 50°C (32 to 122°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
Operating Humidity
10% to 90% non-condensing
10% to 85% non-condensing
10% to 85% non-condensing
Indicators - LEDs
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Panel Cut Out (W x H x D)
Bezel Dimensions and Depth
(W x H x D)
Input Voltage
Power Consumption
Operating Temperature
Storage Temperature
†Consult
4.30
factory for availability.
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Operator Interfaces
QuickPanel View - Europe, Middle East and Africa
Operator Interfaces
Available in a variety of display sizes, the QuickPanel View bundled visualization solution provides
the tools required for today’s application needs. By integrating the best-selling QuickPanel family
of touch screens with award-winning Proficy Machine Edition software, QuickPanel View delivers
flexible, scalable performance on a rugged hardware platform. The intuitive environment of Proficy
View - Machine Edition software helps reduce application development time, and connectivity is
made easy with a family of serial, Ethernet and Fieldbus interfaces. Full-featured QuickPanel View
modules take Operator Interface products to an entirely new level of openness. A built-in web
­server provides access to data and graphics using any standard browser.
IC754VGL06MTD
IC754VHL06MTD
IC754VGL06CTD
IC754VHL06CTD
Product Name
QuickPanel View Display,
6” Mono Loaded
QuickPanel View Display,
6” Mono Loaded
QuickPanel View Display,
6” TFT-Color Loaded
QuickPanel View Display,
6” TFT-Color Loaded
Lifecycle Status
Active
Active
Active
Active
Display Size
5.7 Inch (Diagonal)
5.7 Inch (Diagonal)
5.7 Inch (Diagonal)
5.7 Inch (Diagonal)
Display Type
Monochrome
Monochrome
TFT
TFT
320 x 240 pixels
320x240
320 x 240 pixels
320 x 240 pixels
32 MB
32 MB
32 MB
32 MB
N/A
N/A
To 96 MB
To 96 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
RS232
RS232
RS232
RS232
Ethernet: LAN #1
10/100 Mbps
10/100 Mbps
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
N/A
N/A
N/A
N/A
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
One, Type 2
One, Type 2
One, Type 2
One, Type 2
Agency Approval
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
Environmental Rating
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/12/4X,
IP65 when properly mounted
in an IP65 rated enclosure
Panel Cut Out (W x H x D)
156mm x 123.5mm x 70mm
(6.14” x 4.86” x 2.76”) or
200mm x 155mm x 85mm
(7.95” x 6.12” x 3.33”)
156mm x 123.5mm x 70mm
(6.14” x 4.86” x 2.76”) or
200mm x 155mm x 85mm
(7.95” x 6.12” x 3.33”)
156mm x 123.5mm x 70mm
(6.14” x 4.86” x 2.76”) or
200mm x 155mm x 85mm
(7.95” x 6.12” x 3.33”)
156mm x 123.5mm x 70mm
(6.14” x 4.86” x 2.76”) or
200mm x 155mm x 85mm
(7.95” x 6.12” x 3.33”)
216mm x 170mm x 29mm
(8.50” x 6.68” x 1.13”) or
216mm x 170mm x 7mm
(8.50” x 6.68” x 0.28”)
216mm x 170mm x 29mm
(8.50” x 6.68” x 1.13”) or
216mm x 170mm x 7mm
(8.50” x 6.68” x 0.28”)
216mm x 170mm x 29mm
(8.50” x 6.68” x 1.13”) or
216mm x 170mm x 7mm
(8.50” x 6.68” x 0.28”)
216mm x 170mm x 29mm
(8.50” x 6.68” x 1.13”) or
216mm x 170mm x 7mm
(8.50” x 6.68” x 0.28”)
12 to 30.0 VDC
12 to 30.0 VDC
12 to 30.0 VDC
12 to 30.0 VDC
Power Consumption
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Less than 24W @ 24 VDC
Operating Temperature
-10 to 60°C (14 to 140°F)
-10 to 60°C (14 to 140°F)
-10 to 60°C (14 to 140°F)
-10 to 60°C (14 to 140°F)
Storage Temperature
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
Operating Humidity
10% to 85% non-condensing
10% to 85% non-condensing
5% -90% non-condensing
5% -90% non-condensing
Indicators - LEDs
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Bezel Dimensions and Depth
(W x H x D)
Input Voltage
†Consult
factory for availability.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
4.31
QuickPanel View - Europe, Middle East and Africa
Operator Interfaces
Operator Interfaces
Available in a variety of display sizes, the QuickPanel View bundled visualization solution provides
the tools required for today’s application needs. By integrating the best-selling QuickPanel family
of touch screens with award-winning Proficy Machine Edition software, QuickPanel View delivers
flexible, scalable performance on a rugged hardware platform. The intuitive environment of Proficy
View - Machine Edition software helps reduce application development time, and connectivity is
made easy with a family of serial, Ethernet and Fieldbus interfaces. Full-featured QuickPanel View
modules take Operator Interface products to an entirely new level of openness. A built-in web
­server provides access to data and graphics using any standard browser.
IC754VGF08CTD
IC754VGF12CTD
IC754VGF15CTD
Product Name
QuickPanel View Display,
8” TFT-Color Loaded
QuickPanel View Display,
12” TFT-Color Loaded
QuickPanel View Display,
15” TFT-Color Loaded
Lifecycle Status
Active
Active
Active
Display Size
8.5” (Diagonal)
12.1 Inch (Diagonal)
15.1 Inch (Diagonal)
Display Type
TFT
TFT
TFT
800 x 600 pixels
800 x 600 pixels
1024 x 768 pixels
64 MB
64 MB
64 MB
To 96 MB or 128 MB
To 96 MB or 128 MB
128 MB
Serial: Com #1
RS232/RS485
RS232/RS485
RS232/RS485
Serial: Com #2
RS232
RS232
RS232
Ethernet: LAN #1
10/100 Mbps
10/100 Mbps
10/100 Mbps
Ethernet: LAN #2
None
10/100 Mbps
10/100 Mbps
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
GE Genius,
Data Highway Plus†,
DeviceNet Slave, &
PROFIBUS Slave
One, Type 2
One, Type 2
One, Type 2
Agency Approval
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
UL - Class 1 Div 2 (A, B, C, D)
ATEX - Class 1 Zone 2
CE Mark
Environmental Rating
NEMA 4/4X, UL50 Type 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
NEMA 4/4X,
IP65 when properly mounted
in an IP65 rated enclosure
228mm x 186mm x 77mm
(8.97” x 7.34” x 3.03”)
302mm x 228mm x 60mm
(11.88” x 8.96” x 2.37”)
379mm x 305mm x 71mm
(14.93” x 12.03” x 2.78”)
249mm x 208mm x 9mm
(9.8” x 8.18” x 0.35”)
337mm x 263mm x 10mm
(13.26” x 10.34” x 0.38”)
399mm x 323mm x 10mm
(15.70” x 12.73” x 0.40”)
10.8 to 30.0 VDC
12 VDC @ ±20% or
24 VDC @ ±20%
12 VDC @ ±20% or
24 VDC @ ±20%
24W
Less than 48W @ 24 VDC
Less than 60W @ 24 VDC
0 to 60°C (32 to 140°F)
0 to 50°C (32 to 122°F)
0 to 50°C (32 to 122°F)
-20 to 70°C (-4 to 158°F)
-20 to 70°C (-4 to 158°F)
-20 to 60°C (-4 to 140°F)
Operating Humidity
10% to 85% non-condensing
10% to 85% non-condensing
10% to 85% non-condensing
Indicators - LEDs
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
bi-color (pwr), tri-color (user)
Resolution
Memory: DRAM
Memory: Expandable
Communication Expansion
Compact Flash
Panel Cut Out (W x H x D)
Bezel Dimensions and Depth
(W x H x D)
Input Voltage
Power Consumption
Operating Temperature
Storage Temperature
†Consult
4.32
factory for availability.
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Operator Interfaces
QuickPanel View - Europe, Middle East and Africa
QuickPanel View Communication Hardware
PLC Manufacturer
PLC Type
Part Number
Description
Lifecycle Status
Allen Bradley
SLC500, 5/01, 5/02, 5/03
HMI-CAB-C83
DH-485 Program Port, 8-pin RJ-45Male, RS-422,
No simultaneous connection to program port
Active
HMI-CAB-C84
DH-485 Program Port, 8-pin RJ-45 Male, RS-422,
with simultaneous connection to program port
Active
SLC5/03, 5/04, ControlLogix
HMI-CAB-C52
Channel 0, 9-pin Female, RS-232
Active
PLC-5
HMI-CAB-C51
KF2 Module, 25-pin Female, RS-232
Active
HMI-CAB-C53
Channel 0, 25-pin Male, RS-232
Active
HMI-CAB-C55
KE Module, 15-pin Male, RS-232
Active
HMI-CAB-C107
DF1, 25-pin Male, RS-422
Active
MicroLogix
HMI-CAB-C106
DF1, 8-pin Circular DIN, RS-232
Active
Data Highway Plus
IC754ABD001
Data Highway Plus communication card for QuickPanel View†
Active
DL205 & DL305
HMI-CAB-C86
Programming Port, 6-pin Modular Male, RS-232
Active
DL305 & DL405
HMI-CAB-C103
Programming Port, 4-pin Modular Male, RS-232
Mature
DL305 & DL405 w/ 25-pin comm. port
HMI-CAB-C53
Programming Port, 25-pin Male, RS-232
Active
DeviceNet
IC754DVNS01
DeviceNet Slave Communication Card for QuickPanel View
Active
PROFIBUS
IC754PBSS01
PROFIBUS Slave Communication Card for QuickPanel View
Active
Series 90 CMM Module
HMI-CAB-C53
25-pin Male, RS-232
Active
HMI-CAB-C93
25-pin Male, RS-422
Active
Series 90-30 & 90-70
HMI-CAB-C82
Programming Port, 15-pin Male, RS-422
Active
Series 90-30 CPU351, 352, 363
HMI-CAB-C120
Program Port, 6-pin Male RJ-11, RS-232
Active
VersaMax CPU001, 002, 005
HMI-CAB-C111
Program Port, 9-pin Male, RS-232
Active
VersaMax Nano/Micro
HMI-CAB-C119
Program Port, 8-pin Male RJ-45, RS-232
Active
Genius
IC754GEN001
Genius Communication Card for QuickPanel View & Control
Active
Series A
HMI-CAB-C53
25-pin Male, RS-232
Active
HMI-CAB-C88
9-pin Male, RS-232
Active
Series FX
HMI-CAB-C91
25-pin Male, RS-422
Active
984 A, B, X
HMI-CAB-C53
25-pin Male, RS-232
Active
984 Slot and Compact
HMI-CAB-C58
9-pin Male, RS-232
Active
984 Micro
HMI-CAB-C102
Program Port, 8-pin Male RJ-45, RS-232
Active
C200H
HMI-CAB-C53
25-pin Male, RS-232
Active
HMI-CAB-C108
9-pin Male, RS-422
Active
C20H, CQM1
HMI-CAB-C67
9-pin Male, RS-232
Active
500 Series
HMI-CAB-C53
Programming Port, 25-pin Male, RS-232
Active
HMI-CAB-C101
Programming Port, 9-pin Female, RS-232
Mature
HMI-CAB-C92
9-pin Male, RS-422
Mature
TI545-1102
HMI-CAB-C100
Programming Port, 9-pin Female, RS-422
Active
305 & 405
HMI-CAB-C53
Programming Port, 25-pin Male, RS-232
Active
S7-200 PPI
HMI-CAB-C110
9-pin Male, RS-422
Active
SY/MAX Model 100 & greater
HMI-CAB-C94
9-pin Male, RS-422
Active
SY/MAX Model 50 via link adaptor
HMI-CAB-C53
25-pin Male, RS-232
Active
Automation Direct
Fieldbus
GE
Mitsubishi
Modicon
Omron
Siemens
Square D SY/MAX
Accessories
Part Number
Description
IC754PCMCIA001
PCMCIA Adaptor for QuickPanel View
IC754ACC32MEM
Expansion Memory 32 Mbytes
IC754ACC64MEM
Expansion Memory 64 Mbytes
IC754ACC06GASE
Gasket for 6 Inch QuickPanel View
IC754ACC12GAS
Gasket for 12 Inch QuickPanel View
IC754ACC15GAS
Gasket for 15 Inch QuickPanel View
IC754ACC06MNTE
Mounting Clips & Power Connector for 6 Inch QuickPanel View
IC754ACC12MNT
Mounting Clips & Power Connector for 12 Inch QuickPanel View
IC754ACC15MNT
Mounting Clips & Power Connector for 15 Inch QuickPanel View
IC754ACC06BEZ01
Stainless Steel Bezel for 6 Inch Mono & TFT-Color QuickPanel View
IC754ACC06BEZ02
Stainless Steel Bezel for 6 Inch STN-Color QuickPanel View
IC754ACC12BEZ01
Stainless Steel Bezel for 12 Inch TFT-Color QuickPanel View
IC754BEZ06GAS
Replacement Gasket for 6 Inch Stainless Steel Bezel
IC754BEZ12GAS
Replacement Gasket for 12 Inch Stainless Steel Bezel
IC754ACC12ADP
Adaptor Kit for 12 Inch QuickPanel View into CEIIx Cutout
Adaptor Kit for 8 Inch QuickPanel View into 9" panel
IC754ACC08ADP
†Consult factory for availability.
www.ge-ip.com
Lifecycle Status
Active
Active
Active
Active
Active
Active
Active
Active
Active
Active
Active
Active
Active
Active
Active
Active
GE Intelligent Platforms Control Systems Solutions
4.33
Notes
4.34
GE Intelligent Platforms Control Systems Solutions
Operator Interfaces
www.ge-ip.com
Motion Control Systems
Table of Contents
Motion Controllers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3
PACMotion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3
Servo Amplifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.17
VersaMotion Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.18
αi and βi Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.36
Servo Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.51
αi Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.53
βi Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.65
Motion Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.83
Servo Sizing Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.83
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.1
Table Of Contents
Motion Control Systems
FANUC Digital Servos
Proficy ME
Logic Developer-PLC
IC695PMM335
RX3i
IC695FTB001
Fiber Terminal I/O Block
A66L-6001-0023#Lxxxxx (unsheathed)
A66L-6001-0026#Lxxxxx (sheathed)
FSSB Servo Command Cable
βi SERIES
βHVi SERIES
αHVi SERIES
Motors (cont-peak torque)
β0.4/5000is (0.4-1 Nm)
β0.5/6000is (0.65-2.5 Nm)
β1/6000is (1.2-5 Nm)
β2/4000is (2-7 Nm)
β4/4000is (3.5-10 Nm)
β8/3000is (7-15 Nm)
β12/3000is (11-27 Nm)
β22/2000is (20-45 Nm)
Motors (cont-peak torque)
β2/4000is (2-7 Nm)
β4/4000is (3.5-10 Nm)
β8/3000is (7-15 Nm)
β12/3000is (11-27 Nm)
β22/2000is (20-45 Nm)
Motors (cont-peak torque)
α2/6000HVis (2-6 Nm)
α2/6000HVis (2-6 Nm)
α4/5000HVis (4-8.8 Nm)
α4/5000HVis (4-8.8 Nm)
α8/6000HVis (8-22 Nm)
α8/6000HVis (8-22 Nm)
α12/4000HVis (12-46 Nm)
α12/4000HVis (12-46 Nm)
α22/4000HVis (22-70 Nm)
α30/4000HVis (30-100 Nm)
α40/4000HVis (40-115 Nm)
α50/3000HVis (75-215 Nm)
Amplifier Kits
IC800BIK020
IC800BIK020
IC800BIK020
IC800BIK040
IC800BIK040
Encoder Cables
(Straight x=0; Right Angle x=7)
CFDA-xWPB-0070-AZ (7m)
CFDA-xWPB-0070-AZ (7m)
CFDA-xWPB-0070-AZ (7m)
CFDA-xWPB-0070-AZ (7m)
CFDA-xWPB-0070-AZ (7m)
CFDA-xWPB-0140-AZ (14m)
CFDA-xWPB-0140-AZ (14m)
CFDA-xWPB-0140-AZ (14m)
CFDA-xWPB-0140-AZ (14m)
CFDA-xWPB-0140-AZ (14m)
Power Cables
(Standard x=P; Shielded x=E)
CP8B-1WxB-0070-AZ (7m)
CP3B-0WxB-0070-AZ (7m)
CP5B-0WxB-0070-AZ (7m)
CP6B-0WxB-0070-AZ (7m)
CP8B-1WxB-0140-AZ (14m)
CP3B-0WxB-0140-AZ (14m)
CP5B-0WxB-0140-AZ (14m)
CP6B-0WxB-0140-AZ (14m)
Power & Brake Cable
(Standard x=P; Shielded x=E)
CP9B-0WxB-0070-AZ (7m)
CP9B-0WxB-0140-AZ (14m)
Brake Cables (Optional)
CB6N-5WPM-0070-AZ (7m)
CB4N-0WPM-0070-AZ (7m)
CB4N-0WPM-0070-AZ (7m)
CB4N-0WPM-0070-AZ (7m)
CB6N-5WPM-0140-AZ (14m)
CB4N-0WPM-0140-AZ (14m)
CB4N-0WPM-0140-AZ (14m)
CB4N-0WPM-0140-AZ (14m)
Encoder Battery (Optional)
Built-In (1-axis) Panel Mounted*
IC800BBK021 IC800ABK001
IC800BBK021 IC800ABK001
IC800BBK021 IC800ABK001
IC800BBK021 IC800ABK001
IC800BBK021 IC800ABK001
5.2
Amplifier Kits
IC800BIHV010
IC800BIHV010
IC800BIHV020
IC800BIHV020
Encoder Cables
(Straight x=0; Right Angle x=7)
CFDA-xWPB-0070-AZ (7m)
CFDA-xWPB-0070-AZ (7m)
CFDA-xWPB-0070-AZ (7m)
CFDA-xWPB-0070-AZ (7m)
CFDA-xWPB-0140-AZ (14m)
CFDA-xWPB-0140-AZ (14m)
CFDA-xWPB-0140-AZ (14m)
CFDA-xWPB-0140-AZ (14m)
Power Cables
(Standard x=P; Shielded x=E)
CP3I-0WxB-0070-AZ (7m)
CP3I-0WxB-0070-AZ (7m)
CP4I-0WxB-0070-AZ (7m)
CP3I-0WxB-0140-AZ (14m)
CP3I-0WxB-0140-AZ (14m)
CP4I-0WxB-0140-AZ (14m)
Power & Brake Cable
(Standard x=P; Shielded x=E)
CP2I-0WxB-0070-AZ (7m)
CP2I-0WxB-0140-AZ (14m)
Brake Cables (Optional)
CB4N-0WPM-0070-AZ (7m)
CB4N-0WPM-0070-AZ (7m)
CB4N-0WPM-0070-AZ (7m)
CB4N-0WPM-0140-AZ (14m)
CB4N-0WPM-0140-AZ (14m)
CB4N-0WPM-0140-AZ (14m)
Encoder Battery (Optional)
IC800BBK021
IC800BBK021
IC800BBK021
IC800BBK021
Amplifier Kits
IC800BIHV010
IC800BIHV040
IC800AIHV010
IC800AIHV040
IC800AIHV080
IC800AIHV180
Dynamic Braking Module
ZA06B-6079-H401
Brake Cables (Optional)
CB4N-0WPM-0070-AZ (7m)
CB4N-0WPM-0070-AZ (7m)
CB4N-0WPM-0070-AZ (7m)
CB4N-0WPM-0070-AZ (7m)
CB4N-0WPM-0140-AZ (14m)
CB4N-0WPM-0140-AZ (14m)
CB4N-0WPM-0140-AZ (14m)
CB4N-0WPM-0140-AZ (14m)
Encoder Battery (Optional)
Built-In (1-axis) Panel Mounted*
IC800BBK021 IC800ABK001
IC800BBK021 IC800ABK001
IC800ABK002 IC800ABK001
IC800ABK002 IC800ABK001
IC800ABK003 IC800ABK001
IC800ABK003 IC800ABK001
Power Supply Kits†
IC800PSHV011 (11kW)
IC800PSHV018 (18kW)
IC800PSHV030 (30kW)
IC800PSHV045 (45kW)
Encoder Cables
(Straight x=0; Right Angle x=7)
CFDA-xWPB-0070-AZ (7m)
CFDA-xWPB-0070-AZ (7m)
CFDA-xWPB-0070-AZ (7m)
CFDA-xWPB-0070-AZ (7m)
CFDA-xWPB-0070-AZ (7m)
CFDA-xWPB-0070-AZ (7m)
CFDA-xWPB-0140-AZ (14m)
CFDA-xWPB-0140-AZ (14m)
CFDA-xWPB-0140-AZ (14m)
CFDA-xWPB-0140-AZ (14m)
CFDA-xWPB-0140-AZ (14m)
CFDA-xWPB-0140-AZ (14m)
Power Cables
(Standard x=P; Shielded x=E)
CP2I-0WxB-0070-AZ (7m)
CP2I-0WxB-0070-AZ (7m)
CP3I-0WxB-0070-AZ (7m)
CP3I-0WxB-0070-AZ (7m)
CP4I-0WxB-0070-AZ (7m)
CP4I-0WxB-0070-AZ (7m)
CP9I-0MxB-0070-AZ (7m)
CP2I-0WxB-0140-AZ (14m)
CP2I-0WxB-0140-AZ (14m)
CP3I-0WxB-0140-AZ (14m)
CP3I-0WxB-0140-AZ (14m)
CP4I-0WxB-0140-AZ (14m)
CP4I-0WxB-0140-AZ (14m)
CP9I-0MxB-0140-AZ (14m)
GE Intelligent Platforms Control Systems Solutions
NOTE: Color coding indicates compatible
product matches and applies to products
within a specific series.
* Each panel mounted battery pack can support up to 6 encoders
†One PSM power supply can support up to six αHVi amplifiers
depending on the motor ratings. The power supply must be
sized to match to system power requirements. See the section
“Selecting a Power Supply” on page 50.
www.ge-ip.com
Motion Control Systems
Motion Controllers
Motion Controllers
PACMotion Series
The PACMotion multi-axis motion controller, matched with world
class FANUC digital servos, is designed to deliver unsurpassed
machine productivity required for today’s high-speed machines
and lean manufacturing environments. Hosted by the powerful
PACSystems RX3i controller, PACMotion is part of a complete
automation control solution.
FeaturePACMotion
Architecture Number of Axes Dedicated Master Axis
Servo Command Interface Position Feedback Type Motor Feedback Resolution (counts/rev)
Motion Logic Program
PAC/PLC High Speed Interrupts
Motion Program
Motion Types
Incremental Moves
Absolute Moves
Synchronized Start
Delayed Start
Superimposed Motion
Jogging Homing
Acc/Dec
Cam Function
Cam Queuing
Cam Scaling
Cam Phase Correction
Normalized Cam Profiles
Dynamic Cam Profile Changes
Cam Curve Fitting
Ramping onto Cam Profile
Number of Cam Profiles
Electronic Gearing (Follower) Digital Cam Switch
Shortest Path Absolute Moves
Move Queuing and Blending
Master/Slave Configuration
www.ge-ip.com
PAC-based
Up to 4 FANUC Digital Servos
Up to 2 analog servos
Virtual or Incremental Encoder
Fiberoptic (FANUC Servos)
Analog Velocity/Torque
Serial Encoder; Quad Encoder (analog)
64K, 128K, 1M (FANUC Servos)
Interrupt Driven Task in PAC
3 (time or event)
Integrated Function Blocks or Structured Text
Yes
Yes
Up to 8 axes
Up to 8 axes
Yes
Yes
Yes
Linear/ Programmable Jerk
Advanced
Yes
Master and Slave
Yes
Yes
Yes
1/2/3/5th order
Yes
2048
Advanced
4 High Speed Outputs
Yes
Advanced
Up to 40 Axes over PLC Backplane
GE Intelligent Platforms Control Systems Solutions
5.3
Motion Controllers
Motion Control Systems
PACMotion
PACMotion
The PACMotion controller is a versatile servo motion controller that
combines the benefits of a highly integrated motion and machine logic
solution with the performance, flexibility and scalability required for
advanced machine automation. PACMotion is designed to deliver unsurpassed machine productivity required for today’s high-speed machines
and lean manufacturing environments. The 4-axis servo motion
controller is built on a high performance hardware platform, with a
new enhanced motion engine, operating system, and open standard
integrated programming paradigm. Add to that world class reliability of
FANUC servos and you have a motion system designed to give you the
best productivity and accuracy possible.
Performance to Improve Machine Productivity
• Real-time synchronization of up to 40 axes
• Three high speed time-based or event-driven interrupts enable fast deterministic event response and synchronization
• Demand-driven data exchange model between the PACSystems RX3i CPU and PACMotion modules may significantly
reduce scan time impact
• Digital cam switch (PLS) function with multi-track high-speed outputs with microsecond level response
• Reduced downtime with industry leading FANUC servos featuring MTBF ratings in excess of 400,000 hours
• Low MTTR FANUC servos require no tuning or parameter setting; over 5 million axes sold
Open and Integrated to Improve Engineering Productivity
• Single software development environment with shared tag database for logic, motion, I/O and operator interface
• Motion and machine logic in a common program greatly simplifies programming
• Motion function blocks and state model designed to comply with the PLCopen programming standard to
reduce learning curve and training costs
• Buffer mode allows program logic to queue motion command sequences and specify or change the velocity transition
between buffered moves on-the-fly
• Advanced diagnostic tools included in Proficy software speed diagnostics and machine time to market
Flexibility and Scalability
• Four servo axes per module; Up to 40 axes in a single PACSystems RX3i rack
• Built-in faceplate I/O and optional fiber I/O terminal block supports extensive user configurable digital and analog I/O
• Amplifiers and motion I/O can be physically distributed using noise immune fiber optic interfaces
• Virtual (time-based) or real (encoder) master axes over the backplane support advanced cam and electronic
gearing applications for flexible electronic line shaft applications
5.4
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Motion Controllers
PACMotion
Each PACMotion module can control up to 4 axes of FANUC βi, βHVi or αHVi servos via a fiber optic command interface for superior
noise immunity, especially in distributed systems. By combining the versatility of the GE PACSystems RX3i and QuickPanel operator
interface products, GE provides customers with a complete integrated machine control solution. This single-source system results in
such benefits as ease of integration and programming, shorter development cycles, and higher reliability.
PACMotion System Configuration
PSM-HVi
Power Supply
αHVi Series
Amplifier
αHVi Series
Amplifier
D
D
αHVi Series
Amplifier
αHVi Series
Amplifier
D
D
Operator Interface
αHVi/αHVis Series αHVi/αHVis Series αHVi/αHVis Series αHVi/αHVis Series
Servo Motor
PACSystems
RX3i
βi/βHVi Series
Amplifier
D
C
E
Servo Motor
βi/βHVi Series
Amplifier
D
FANUC
Servo Motor
βi/βHVi Series
Amplifier
D
FANUC
Servo Motor
βi/βHVi Series
Amplifier
D
FANUC
FANUC
Help
STATUS
MONITORING
: GE FANUC--CIMP
LICITY
Exit
Options
Keyboard
Machine
Info
Order
2 Production
PRDT-0004
Number Cover
11 Day
Product Name
7 Month
Product
n Date
38 %
Completio
Rate
Prdt
Order
167885
%
Plan
100
941
Rate
5
Shot
Good
4705
Pro Count
Prdt.
941
Good
Shot
Good
Help
Machine
2
ALARM
Cycle
4.36
T
Inj. T
0.72
Sec
High
Sec
Speed
Ext. T
2.42
Pressure
Size
Shot
In
1.467
Sec
M-CUSH
0.204
Prev
Temperatu
re Readings
Nozzle
1
2
3
or Barrel
4
1
2
32
303
387 369
32 419
5
7
6
8
400
0
Exit
In
Hold
Readings
200
Enter
A
Status
Control
Next
Select
0
0
0
0
Remove
Proficy Machine Edition
Logic Developer – PLC
βis/βHVis Series βis/βHVis Series βis/βHVis Series βis/βHVis Series
Servo Motor
D
B
­
Servo Motor
Servo Motor
F
Terminal Board
Terminal Board
VersaMotion
Series
Amplifier
and Motor
VersaMotion
Series
Amplifier
and Motor
Fiber Terminal Block
(FTB)
Part Number
A Motion Controller
IC695PMM335
B Motion I/O Expansion
IC695FTB001
IC695FTB1B032
IC695FTB1S032
IC695FTB1B132
IC695FTB1S132
C Communication Cable
IC693CBL316
ZA66L-6001-0023#L150R0
D Fiber Optic Cables ZA66L-6001-0023#L300R0 ZA66L-6001-0023#L1R003
ZA66L-6001-0023#L2R003
ZA66L-6001-0023#L3R003
ZA66L-6001-0026#L1R003
ZA66L-6001-0026#L3R003 ZA66L-6001-0026#L5R003
ZA66L-6001-0026#L10R03
ZA66L-6001-0026#L20R03
ZA66L-6001-0026#L30R03 ZA66L-6001-0026#L50R03 ZA66L-6001-0026#L100R3
E­­Proficy Programming Software IC646MPP001 IC646MBP001 F VersaMotion Interface
IC800VMTBC005
www.ge-ip.com
Servo Motor
F
Description
APPLICATIONS
PACMotion Motion Controller for RX3i
Optional Fiber Terminal Block (without terminal headers)
Optional Fiber I/O Terminal Block
(with screw terminal headers)
Optional Fiber I/O Terminal Block
(with spring clip terminal headers)
Optional Fiber I/O Terminal Block
(with extended shroud screw terminal headers)
Optional Fiber I/O Terminal Block
(with extended shroud spring clip terminal headers)
Serial Cable for Programming - 3m (1 per system)
FSSB and FTB I/O Cable 0.15 Meter
FSSB and FTB I/O Cable 0.3 Meter
FSSB and FTB I/O Cable 1 Meter
FSSB and FTB I/O Cable 2 Meter
FSSB and FTB I/O Cable 3 Meter
FSSB and FTB I/O Cable Sheathed, 1 Meter
FSSB and FTB I/O Cable Sheathed, 3 Meter
FSSB and FTB I/O Cable Sheathed, 5 Meter
FSSB and FTB I/O Cable Sheathed, 10 Meter
FSSB and FTB I/O Cable Sheathed, 20 Meter
FSSB and FTB I/O Cable Sheathed, 30 Meter
FSSB and FTB I/O Cable Sheathed, 50 Meter
FSSB and FTB I/O Cable Sheathed, 100 Meter
Logic Developer PLC Professional without GlobalCare.
Complete with Software key
Machine Edition Professional Development Suite without
GlobalCare. Complete with Software key
I/O breakout terminal board and 0.5 meter cable (1 per VersaMotion axis)
• High-speed printing
• Packaging systems
• High-speed assembly
• Woodworking machinery
• Automotive assembly
• Material handling
• Web handling applications
• Infeed conveyors
• Labeling
• Filling
GE Intelligent Platforms Control Systems Solutions
5.5
Motion Controllers
Motion Control Systems
PACMotion
PACMotion Controller Features
• Fast motion path (1ms) planning and position update rates (500µs) deliver improved accuracy and faster response to
changing control requirements
• Unlike most PLC-based motion, PACMotion delivers consistent motion update rate regardless of the number of axes
• High reliability FANUC servos improve machine uptime
• High speed synchronization of up to 40 axis over the PACSystems RX3i backplane
• Advanced cam and gearing features for electronic line shaft applications
• Single software development environment for complete automation control solution simplifies programming
• Distributed architecture for greater machine flexibility–up to 100 meters between axes using noise immune fiber cables
• Optional Fiber Terminal Block allows distributed motion centric I/O to reduce wiring complexity and cost
• Two high-speed position capture inputs per axis for registration and sequence control
Unlimited master/slave synchronization
of any axis to any other axis over the
PACSystems RX3i backplane
Axis and Status LEDs
Hot-swap module in
PACSystems RX3i rack
Fiber optic servo interface
(up to 4 axes)
8 on-board 24V I/O
Fiber optic I/O interface
Synchronized or delayed
start of up to any 8 axes
Optional Fiber Terminal Block I/O
•
•
•
•
•
•
DIN rail mounting
Remote mount up to 100 meters
5V/24V/Analog I/O
Unique ID prevents connection to wrong PACMotion module
Configurable I/O functions can be assigned to each point
Connection for up to 5 incremental encoders without marker
or 4 encoders with marker pulse
5.6
High density plug-on wiring headers available with
spring clip or screw terminals and extended shroud
(ordered separately)
βi and βHVi Servos
αHVi and αHVis Series Servos
• 0.4 to 22 Nm cont. torque range
• 230 and 460 VAC models
• Noise immune fiber optic interface
• Absolute feedback with optional battery
• 64K or 128K count/rev serial encoder
• Optional holding brake
•
•
•
•
•
•
GE Intelligent Platforms Control Systems Solutions
2 to 140 Nm cont. torque range
460 VAC line regenerative power supplies
Noise immune fiber optic interface
Absolute feedback with optional battery
1M count/rev serial encoder
Optional holding brake
www.ge-ip.com
Motion Control Systems
Motion Controllers
PACMotion
Packaging
Faster product turnover, greater variability and shorter production runs are at the heart of some key packaging machinery automation
trends in industries such as pharmaceutical, food and beverage and consumer packaged goods. Today’s automation systems must
provide the flexibility and scalability to keep pace with this explosion of new product introductions, while delivering higher speed, accuracy and reliability to boost line productivity and asset utilization. End users and OEMs alike are now choosing innovation over supplier
standardization in order to optimize machine performance. Partnering with automation suppliers who offer complete integrated control
solutions can speed time to market and reduce development and deployment costs. Third generation packaging machines demand
the PACMotion advantage…high performance multi-axis motion control tightly integrated with a Process Automation Controller (PAC),
operator interface and extensive communications options all tied by one powerful software environment... PACMotion delivers.
• Form, fill and seal
• Smart conveyors
• Cartoning
• Wrapping
• Filling and capping
• High speed labeling
• Sorting/Diverting
Traditional Mechanical Line Shaft
Gearbox
Flexible Electronic Line Shaft
Motor
Controller
Amplifier
Servo
Motor
Printing
Many of the trends driving automation changes in the packaging industry are mirrored by the printing industry. Shorter print runs with
greater product variability require flexible, modular machine configurations, higher production speeds while maintaining accurate
registration and quick start-up and changeover.
Shaftless press designs offer mechanical simplicity, reduced noise levels, improved flexibility and high reliability to reduce total cost
of ownership. PACMotion is part of a complete automation system that tightly integrates line control, motion and operator interface
functions in a single software environment, reducing the design cycle for new press designs or line retrofits. PACMotion delivers the
performance and scalability required by today’s printing lines.
• Flexographic
• Gravure
• Offset
• Winders/Unwinders
• Laminators
• Registration
• Dryer control
• Infeed rollers
• Draw rollers
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.7
Motion Controllers
Motion Control Systems
PACMotion
Material Handling and High-Speed Assembly
Price pressure, smaller products and shorter life cycles in automotive, medical and electronic products require lean manufacturing lines
with the flexibility to allow assemblers to reduce time to market for new products and build many product variations on the same line.
Smaller products require automation and motion control systems that can meet the increased assembly precision at ever increasing production speeds. System reliability is a crucial element to maintaining the high production rates necessary to reduce total cost per assembly.
PACMotion is part of a complete automation system that tightly integrates material handling and assembly line control, motion
and operator interface functions in a single software environment, improving engineering productivity and delivering faster time to
market. PACMotion delivers the precision and flexibility to meet demanding assembly and handling challenges.
• Engine/Transmission Assembly
• Transfer Lines
• Test Stands
• Rotary Dial Tables
• Electronic Assembly
• Adhesive Dispensing
• Smart Conveyors
• Baggage Handling Systems
Converting and Web Handling
Increasing line speed while reducing scrap is a critical factor in maintaining a competitive edge in the web handling and material
converting applications. Greater product variability requires flexible modular control systems that enable instant changeover from one
product run to the next. Adjusting for different web widths, repositioning edge guides and slitter position, changing cut length, and
rewind tension must be fast and accurate. Servo control technology replaces traditional mechanical adjustments, allowing for precise
and repeatable adjustments. Programmable jerk control reduces web breaks and film stretching while high servo response ensures
fast corrections to web disturbances. PACMotion is part of an integrated automation system for device and I/O control, motion and
operator interface to facilitate efficient programming and powerful diagnostics in a single software environment.
• Laminating
• Carton Folding
• Rotary Die Cutting
• Folder/Gluers
• Unwinders/Rewinders
• Slitter Positioning
5.8
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Motion Controllers
PACMotion
Open and Integrated to Improve Engineering Productivity
Synchronization of separate motion and logic programs and the lack of open motion programming standards can present a challenge
even for simple motion applications. Proficy Machine Edition provides one tool for control, view, and motion and provides one universal
engineering development environment for all programming, configuration, and diagnostics, resulting in faster time to solution, reduced
training, and more compact, efficient design. The high level of PACMotion integration with the RX3i platform can significantly reduce
system engineering and commissioning costs:
• Motion and machine logic in a common program greatly
simplifies programming
• Motion function blocks and state model designed to comply
with the PLCopen programming standard, reduce learning
curve and training costs
• Buffer mode allows program logic to queue motion command
sequences and specify or change the velocity transition
between buffered moves on-the-fly
• All Proficy Machine Edition components— view, logic, and
motion— share a common database and common objects
across applications, including logic, scripts, and animation.
Once a variable is created, it can easily be used in all other
domains of the application.
• Proficy Machine Edition components share common development tools such as a common user interface, drag-and-drop
editing, and takes full advantage of industry-standard technologies like MEL, COM/DOM, OPC and ActiveX.
• Proficy Machine Edition supports IEC languages such as Relay
Ladder, Instruction List, Structured Text, Function Block, and
SFC programming. In addition, C programming and Open
Process are available.
Powerful Diagnostic Tools
The Data Logger supports the high-speed capture of up to 48
parameters per PACMotion module.
• Logging session can be single shot or continuous
• Sample rates as fast as 500 µs
• Data collection can be set to start based on a trigger event
• Captured data is stored as PLC files and can be archived or
viewed using the Data Logger Window
The Diagnostic Logic Block is a separate program that runs
independently of the main application program.
• Uses the standard Ladder editor
• Can be executed with the PLC in the Run or Stop
I/O Enabled mode
• Library of DLBs can be reused for functions such as machine
troubleshooting, servo tuning, data logging, etc.
• DLBs can be saved as toolchest objects
• Program code can be cut/pasted between a DLB and the main
program providing a convenient way to test new code segments
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.9
Motion Controllers
Motion Control Systems
PACMotion
PACMotion Module Specifications
SpecificationDetails
Comments
Motion Path Planning
1 ms
Position Loop Update Rate
500 µs
Velocity Loop Update Rate*
125 µs
Torque Loop Update Rate*
62.5 µs
Controlled Axes/Module
4
2
Master Axes/Module
1
Servo Command Interface
Fiber Optic
FSSB Cable Length max. 100 meters between nodes
Maximum Axes per RX3i:
DC Power Supplies
40 + 10 master axes
AC Power Supplies
32 + 8 master axes
Position Resolution:
αHVi Series
1,048,576 counts/rev
βi and βHVi Series
65,536 or 131,072 counts/rev
Analog Axes
10,000 counts/rev
Feedback Type
Incremental/Absolute Serial Encoder
Faceplate I/O:
24V General Purpose Inputs
4 optically isolated; source/sink
24V High-Speed Inputs
2 optically isolated; source/sink
24V General Purpose Inputs/Outputs 2 optically isolated; source/sink
Connector
Plug-on Screw Terminal
Floating Point Support
Yes
Module Hot Insertion/Removal
Yes
Cam Profiles per Module
256 at one time
Synch/Delayed Start
Up to 8 axes
High Speed Position Capture
2 Inputs per axis
Consistent update regardless of the number of axes in the system
All axes in the RX3i rack are updated simultaneously
All axes in the RX3i rack are updated simultaneously
All axes in the RX3i rack are updated simultaneously
βi, βHVi or αHVi series servos are supported via a fiber optic interface
VersaMotion or third party servos via 10Vdc analog velocity or torque command interface
Can be a virtual time-based or incremental encoder master
50 Mb/s FANUC Serial Servo Bus (FSSB)
400 meters maximum for a 4 axis system
Requires 16 slot backplane, CPU and 4 DC power supplies
Requires 16 slot backplane, CPU and 3 AC power supplies
—
β2i and larger motors support the higher resolution
VersaMotion servo resolution (third party servo resolution dependent on feedback used)
Optional battery backup required for absolute feedback mode
—
Open circuit detection; can be used to connect a quadrature master encoder (500 kHz max)
125 mA maximum output current each
—
Double precision IEEE 754
—
Up to 2048 profiles can be stored in the RX3i file system for use by any module
Axes can be on any module and are synchronized over the backplane
± 1 count = 10 µs jitter
* For analog servos the velocity and the torque loop update rate will depend on the command interface mode selected in the PACMotion module and the update rate of the specific analog ampliflier.
Fiber Terminal Block Specifications
SpecificationDetails
Comments
Mounting
35 mm DIN Rail
Dimensions:
inches
5.56 W x 4.94 H x 2.46 D
mm
141.2 W x 125.5 H x 62.5
Interface to PACMotion Module
Fiber Optic Cable
Terminal Header Options
IC694TBS032
High Density 36 point Spring Clip Terminals
IC694TBB032
High Density 36 point Captive Screw Terminals
IC694TBS132
High Density Spring Clip Terminals, Extended Shroud
IC694TBB132
High Density Captive Screw Terminals, Extended Shroud
Power Requirements
19.2VDC —28.8VDC; 0.45 Amps @ 24V
24V Outputs (differential)
8 optically isolated; source; open load & short detection
24V General Purpose Inputs
16 optically isolated; source/sink
5V Outputs (differential)
4
5V Inputs (differential/single-ended)
6
5V Inputs (differential)
6
Analog Inputs
2, ±10V differential
Analog Outputs
2, ±10V single-ended
24 V Power Output
5 V Power Output
0.5 amp max.
Quad Encoder Open Circuit Detection
Yes
I/O Function Assignment
Configurable
Must be mounted on a vertical surface for proper cooling
5.10
GE Intelligent Platforms Control Systems Solutions
—
—
Maximum cable length is 100 meters; Interface uses a unique ID for each PMM/FTB pair to prevent cross-connection
2 required per FTB (ordered separately); 14-26 AWG
2 required per FTB (ordered separately); 14-26 AWG
2 required per FTB (ordered separately); 14-28 AWG
2 required per FTB (ordered separately); 14-28 AWG
one AWG #14 (2.1mm2) or two AWG #16 (1.3mm2)
copper wires per terminal
2 groups of 4; 0.5 A max. per point; 4 A max. per group
4 groups of 4
RS422 Line Driver with short circuit protection; 48 mA max.
RS422 / RS485 Line Receiver with fault detection
RS422 / RS485 Line Receiver with fault detection
14 bit resolution
12 bit resolution
Reverse polarity protected by replaceable fuse
electronic overload protected
—
I/O functions are assigned during
module hardware configuration www.ge-ip.com
Motion Control Systems
Motion Controllers
PACMotion
Fiber Terminal Block (FTB) Dimensions
4.35
5.56
4.94
2.13
.17
.81
1.30
.97
1.26
2.46
4.56
www.ge-ip.com
2.84
4.30
4.56
GE Intelligent Platforms Control Systems Solutions
5.11
Motion Controllers
Motion Control Systems
PACMotion
Fiber Terminal Block IC695FTB001 Wiring Diagram and Pin Assignments
FTB Terminal 1 Pin Assignments
FTB Terminal 1 Wiring Diagram
Pin
Circuit Identifier
Circuit Type
Default Circuit Function
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
24V+
Q1
Q2
24-
I1
I2
I3
I4
+5V (OUT)
I17+
I17-
I18+
I18-
I19+
I19-
AI1+
AI1-
Shield
24V-
Q3
Q4
24V-
I5
I6
I7
I8
0V
I20+
I20-
I21+
I21-
I22+
I22-
AO1+
COM
Shield
24V Output
24 VDC (ESCP) Output
24 VDC (ESCP) Output
24V-
24 VDC Input
24 VDC Input
24 VDC Input
24 VDC Input
+5V Output
5V Diff Input+
5V Diff Input-
5V Diff Input+
5V Diff Input-
5V Diff Input+
5V Diff Input-
± 10V Analog Input
± 10V Analog Input
Shield
24V-
24 VDC (ESCP) Output
24 VDC (ESCP) Output
24V-
24 VDC Input
24 VDC Input
24 VDC Input
24 VDC Input
0V
5V Diff Input+
5V Diff Input-
5V Diff Input+
5V Diff Input-
5V Diff Input+
5V Diff Input-
±10V Analog Output
±10V Analog Output
Shield
Q1—Q4 Power
24V Output
24V Output
I1—I4 Common
Digital Input
Digital Input
Digital Input
Digital Input
External Power
Fast Digital Input
Fast Digital Input
Fast Digital Input
Fast Digital Input
Fast Digital Input
Fast Digital Input
Analog In 1 (+)
Analog In 1 (–)
Frame Ground
Q1—Q4 Common
24V Output
24V Output
I5—I8 Common
Digital Input
Digital Input
Digital Input
Digital Input
External Power
Fast Digital Input
Fast Digital Input
Fast Digital Input
Fast Digital Input
Fast Digital Input
Fast Digital Input
Analog Out 1
AO1 Common
Frame Ground
F ield W iring
T erm in als
+
1
19
2
20
24V
Q1
24V
Q3
24V
Q2
24V
–
+
I1
I2
I3
+
–
I4
+5V
( OU T )
5V
( +)
24V
3
21
4
22
5
23
6
24
7
25
8
26
9
27
10
28
I17
( –)
5V
( +)
5V
11
29
12
30
13
31
( +)
±10V
14
32
S HIE L D
–
I5
+
I6
I7
+
I8
–
0V
( +)
5V
( –)
( +) 5V
( –)
( +)
5V
I22
15
33
16
34
A I1
( –)
24V
I21
I19
( –)
Q4
I20
I18
( +)
GE Intelligent Platforms Control Systems Solutions
24V
–
( –)
5.12
F ield W irin g
( –)
( +)
±10V
A O1
17
18
35
36
COM
S HIE LD
www.ge-ip.com
Motion Control Systems
Motion Controllers
PACMotion
Fiber Terminal Block IC695FTB001 Wiring Diagram and Pin Assignments
FTB Terminal 2 Pin Assignments
Pin
Circuit Identifier
1
24V+
2
Q5
3
Q6
4
5
I9
6
I10
7
I11
8
I12
9
+5V (OUT)
10
I23+
11
I23-
12
I24+/Q9+
13
I24-/Q9-
14
I25+/Q10+
15
I25-/Q10-
16
AI2+
17
AI2-
18
SHIELD
19
24V-
20
Q7
21
Q8
22
24V+
23
I13
24
I14
25
I15
26
I16
27
0V
28
I26+
29
I26-
30
I27/Q11+
31
I27/Q11-
32
I28/Q12+
33
I28/Q12-
34
AO2+
35
COM
36
SHIELD
FTB Terminal 2 Wiring Diagram
Circuit Type
Default Circuit Function
24V Output
24 VDC (ESCP) Output
24 VDC (ESCP) Output
24V+
24 VDC Input
24 VDC Input
24 VDC Input
24 VDC Input
+5V OUT
5V Diff Input+
5V Diff Input-
5V Diff Input+/5V
Diff Output+
5V Diff Input-/5V Diff Output-
5V Diff Input+/5V Diff Output+
5V Diff Input-/5V Diff Output-
±10V Analog Input
±10V Analog Input
Frame Ground
24V-
24 VDC (ESCP) Output
24 VDC (ESCP) Output
24V+
24 VDC (ESCP) Input
24 VDC (ESCP) Input
24 VDC (ESCP) Input
24 VDC (ESCP) Input
0V
5V Diff Input
5V Diff Input
5V Diff Input+/5V Diff Output+
5V Diff Input-/5V Diff Output-
5V Diff Input+/5V Diff Output+
5V Diff Input-/5V Diff Output-
± 10V Analog Output
± 10V Analog Output
Frame Ground
Q5—Q8 Power
24V Output
24V Output
I9—I12 Common
Digital Input
Digital Input
Digital Input
Digital Input
External Power
Fast Digital Input
Fast Digital Input
Fast Digital Input
F ield W iring
1
19
2
20
24V
Q5
24V
Q6
24V
–
+
I9
I10
I11
+
I12
–
+5V
( OU T )
5V
( +)
24V
3
21
4
22
5
23
6
24
7
25
8
26
9
27
10
28
I23
( –)
5V
( +)
11
29
12
30
13
31
14
32
I24/Q 9
( –)
Fast Digital Input
( +)
5V
24V
–
I13
+
I14
I15
+
I16
–
0V
( +)
5V
( –)
( +)
( –)
( +) 5V
I27/Q 11
I25/Q 10
Analog Output 2
AO2 Common
Shield
Q8
I16
±10V
( –)
( +)
5V
I28/Q 12
15
33
16
34
A I2
( –)
( +)
±10V
A O2
17
( –)
S HIE L D
www.ge-ip.com
Q7
24V
Fast Digital Input
Fast Digital Input
24V
–
Fast Digital Input
Fast Digital Input
F ield W irin g
+
Fast Digital Input
Analog In 2 (+)
Analog In 2 (-)
Shield
Q5—Q8 Common
24V Output
24V Output
I13—I16 Common
Digital Input
Digital Input
Digital Input
Digital Input
External Power
Fast Digital Input
Fast Digital Input
Fast Digital Input
T erm in als
18
35
36
COM
S HIE LD
GE Intelligent Platforms Control Systems Solutions
5.13
Motion Controllers
Motion Control Systems
PACMotion
VersaMotion amplifier connection to the PACMotion Fiber Terminal Block
Up to two VersaMotion amplifiers can be connected to each PACMotion module using the two analog outputs on the Fiber Terminal
Block (FTB). The VersaMotion amplifier includes an encoder output that is also connected to the FTB for axis feedback. The interface
between the VersaMotion amplifier CN1 connector and the FTB can be made directly using the IC800VMCI010 (1 m) or IC800VMCI030
(3 m) flying lead I/O interface cable or using the IC800VMTBC005 I/O terminal breakout board and included 0.5 meter cable. This
terminal board will allow easy access to any additional I/O connections to the VersaMotion amplifier from field devices such as emergency stop circuits. The proper wiring interface is shown for direct connection to the CN1 connector however, terminal numbers are
the same for the breakout terminal board.
VersaMotion
CN1
FTBTerminal 1
AO1+ (34)
V_REF (42)
A_COM (35)
GND (44)
GND (12)
GND (13)
0 V (27)
GND (19)
OA (21)
I17+ (10)
/OA (22)
I17- (11)
OB (25)
I18+ (12)
/OB (23)
I18- (13)
OZ (50)
I19+ (14)
/OZ (24)
I19- (15)
Q3 (20)
COM+ (11)
DO1+ (7)
DO1- (6)
I5 (23)
24V_IN- (22)
COM- (45)
DI1 (9)
24V_OUT- (19)
DI8 (30)
24V_OUT+ (1)
VDD (17)
FTB Power
5.14
GE Intelligent Platforms Control Systems Solutions
VDC
GND
www.ge-ip.com
Motion Control Systems
Motion Controllers
PACMotion
Motion Functions
Function Block Name
Description
Single Axis Administrative Function Blocks
MC_Power
MC_ReadStatus
MC_ReadAxisError
MC_ReadParameter
MC_ReadParameters
MC_ReadBoolParameter
MC_ReadBoolParameters
MC_ReadDwordParameters
MC_WriteParameter
MC_WriteParameters
MC_WriteBoolParameter
MC_WriteBoolParameters
MC_WriteDwordParameters
MC_ReadActualPosition
MC_Reset
MC_ModuleReset
MC_ReadDigitalInput
MC_ReadDigitalOutput
MC_WriteDigitalOutput
MC_SetPosition
MC_SetOverride
MC_ReadActualVelocity
MC_ReadTorqueCommand
MC_LibraryStatus
MC_ReadAnalogInput
MC_ReadAnalogOutput
MC_WriteAnalogOutput
MC_ReadEventQueue
MC_TouchProbe
MC_AbortTrigger
MC_DigitalCamSwitch
MC_DL_Configure
MC_DL_Activate
MC_DL_Get
MC_DL_Delete
Controls the Power Stage (MCON); causes all control loops to be closed and the control to be in the Standstill state
ready to perform motion commands
Returns in detail the current axis status of the axis selected
Indicates general axis errors not relating to the execution of Functions or Function Blocks;
used to read a current error or warning on the axis
Returns the value of a parameter; used to read an axis parameter
Returns the values of parameters; used to read one or more axis parameters
Returns the value of a Boolean parameter; used to read an axis parameter
Returns the values of Boolean parameters; used to read one or more axis parameters
Returns the values of 32 bit word parameters; used to read one or more axis parameters
Modifies the value of a parameter; used to write an axis parameter
Modifies multiple parameter values; used to write multiple axis parameters
Modifies the value of a vendor specific parameter; used to write an axis parameter
Modifies multiple Boolean parameter values; used to write multiple axis parameters
Modifies multiple 32 bit word parameter values; used to write parameters that can not be expressed as real
including packed bits
Used to read the actual axis position
Makes the transition from the state ErrorStop to StandStill by resetting all internal axis-related errors;
used to attempt to clear any errors on an axis and return it from the ErrorStop state to the Standstill state
Makes the transition from the state ErrorStop to StandStill by resetting all internal errors;
used to attempt to clear any errors on a module and return any axes in the ErrorStop state to the Standstill state
Gives access to the value of the input, referenced by the datatype INPUT_REF;
provides the value of the referenced input (BOOL).
Gives access to the value of an output, referenced by the datatype OUTPUT_REF;
provides the value of the referenced output (BOOL)
Writes a value to a discrete output once (with Execute), referenced by the datatype OUTPUT_REF
Shifts the coordinate system of an axis by manipulating both the set-point position as well as the actual position of
an axis with the same value without any movement caused. (Re-calibration with same following error).
Sets the values of override for the whole axis, and all functions that are working on that axis
Returns the value of the actual velocity as long as Enable (EN) is set
Returns the value of the torque command as long as Enable (EN) is set
Provides the user with visibility into their cam-profile memory usage; provides the number of selected cam-profiles,
the total number of bytes available, and the percentage of memory used
Gives access to the value of an analog input, referenced by the datatype INPUT_REF
Gives access to the value of an analog output, referenced by the datatype OUTPUT_REF
Writes a value to an analog output once (with Execute), referenced by the datatype OUTPUT_REF
Returns the current PMM module event queue
Used to record an axis position at a strobe trigger event
Used to abort MC_TouchProbe function blocks
Commands a group of discrete output bits to switch in analogy to a set of mechanical cam controlled switches
connected to an axis
Specifies the configuration parameters for data logged on the PMM
Used to start data logging on the module in normal start mode
Writes the data logged into a file specified by the DATALOG_FILE_REF input
Responsible for deleting data logger configuration from the PMM memory
Single Axis Motion Function Blocks
MC_MoveAbsolute
MC_MoveRelative
MC_MoveAdditive
MC_MoveSuperimposed
MC_MoveVelocity
MC_Home
MC_Stop
MC_JogAxis
MC_Halt
Commands a controlled motion at a specified position
Commands a controlled motion of a specified distance relative to the actual position at the time of the execution
Commands a controlled motion of a specified relative distance additional to the original commanded position
in the discrete motion state
Commands a controlled motion of a specified relative distance additional to an existing motion
Commands a never ending controlled motion at a specified velocity
Commands the axis to perform the «search home» sequence
Commands a controlled motion stop and transfers the axis to the state “Stopping”
Jogs an axis forward or backward at the manual operation velocity and acceleration
Commands a controlled motion stop
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.15
Motion Controllers
Motion Control Systems
PACMotion
Motion Functions
Multiple Axis Administrative Function Blocks
MC_CamTableSelect
MC_CamTableDeselect
Selects the cam-tables (cam-profiles) by setting the pointers to the relevant tables
Deletes a cam-profile from the specified module to free memory
Multiple Axis Motion Function Blocks
MC_CamIn
MC_CamOut
MC_GearIn
MC_GearOut
MC_Phasing
MC_GearInPos
MC_SyncStart
MC_DelayedStart
Engages a cam
Disengages a slave axis from the master
Commands the slave axis velocity at a ratio of the master axis velocity
Used to disengage from a MC_GearIn function block
Provides dynamic phase shifting capability for cam profiles
Commands a gear ratio between the position of the slave and master axes from the synchronization point onwards
Identifies which axes should be started at the same time and how much time can elapse before the motion must start
Identifies which axes should be started with a delay relative to each other and how much time can elapse
before the motion must start
PLC Support Function Blocks
MC_CamFileRead
MC_CamFileWrite
Copies the contents of a cam file from the PLC file system into reference memory
Copies cam data from reference memory to an existing cam file in the PLC file system,
overwriting the original data in the cam file
5.16
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Amplifiers
Servo Amplifiers
VersaMotion* Series
The VersaMotion family of servo amplifiers offers a cost effective solution for a broad range of motion applications. These
versatile amplifiers support stand-alone positioning capability
using up to 8 stored motion profiles, or can be connected to any
motion controller using an analog or pulse command interface.
The VersaMotion Servo Amplifiers are matched for use with the
VersaMotion Servo Motors.
αi and βi Series
The all digital αi and βi Series Servo Amplifiers, with over five
million installed worldwide, offer superior reliability and performance for unprecedented mean time between failure. They are
available in a wide range of ratings for use with GE PACMotion
Series motion controller, and are matched for use with the αi and
βi Series Servo Motors.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.17
Servo Amplifiers
Motion Control Systems
VersaMotion
The VersaMotion family of servo amplifiers offers a cost effective
solution for a broad range of motion applications. These versatile
amplifiers support simple stand-alone positioning capability
using up to 8 stored motion profiles or can be connected to any
motion controller using an analog or pulse command interface. A
built-in touchpad and display provides convenient access to
configuration parameters and system information. The serial
interface supports multi-drop system configurations and Modbus
communication protocol.
Amplifier setup can be accomplished using the VersaMotion
software included with Proficy Machine Edition or using the
convenient front panel keypad.
Key Features
• Versatile analog (speed or torque) or pulse command interface
• Position/Speed/Torque modes
• Dual control modes
• Standalone single-axis position control mode for simple pointto-point motion control
• Electronic gearing with user-defined ratio
• External JOG function
• Speed/Torque limit operation
• Built-in keypad/display for setup and diagnostics
• Motor settling time below 1 ms for fast response
• Low speed stability and performance: less than 0.5% error
at 1 RPM
• 10msec acceleration time from running without load
-/+ 3000 RPM
Built-in Functions
Machine Edition VersaMotion Set-up Features
• Simple stand-alone point-to-point positioning control with
8 internal stored position settings (positions can be changed
over Modbus for greater application flexibility)
• Move to Home function
• Position Teaching capability
• Incremental encoder feedback (2500 ppr/10,000 counts/rev)
• User-definable Acceleration/Deceleration with jerk limiting
(s-curve)
• Feed step control function
• Modbus Slave serial port (RS-485/RS-422) for reading and
writing parameters from Machine Edition or updating stored
position set points from a host controller.
• Configuration Parameter Editor (clear, read, write functions)
and initial configuration wizard
• Calculation tools to determine proper conversion from encoder
counts to desired user programming units
• Three channel digital oscilloscope to display and record drive
status on-line
• Alarm history and status monitor diagnostic screens
• Digital I/O set-up, monitoring and forcing. Each I/O point can
be individually set to one of the built-in functions (45 digital
input functions and 11 digital output functions)
5.18
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Amplifiers
VersaMotion
Servo Amplifier Part Number Sequence
IC800VMA
04
2
Input Voltage
2– 220 VAC
Rated Power
01– 100 Watts
02– 200 Watts
04– 400 Watts
07– 750 Watts
10– 1000 Watts
20– 2000 Watts
30–­ 3000 Watts
Example: IC800VMA042 is a 400 Watt 220 VAC servo amplifier
Amplifier Specifications
Part Number
IC800VMA012 IC800VMA022 IC800VMA042 IC800VMA072 IC800VMA102 IC800VMA202 IC800VMA302
Rated Output Power
100W
200W
400W
750W
1000W
2000W
3000W
Voltage/ Frequency
Three-phase or Single-phase 220VAC; 50/60 Hz
Three-phase or Single-phase 220VAC; 50/60 Hz
Three-phase or Single-phase 220VAC; 50/60 Hz
Three-phase or Single-phase 220VAC; 50/60 Hz
Three-phase or Single-phase 220VAC; 50/60 Hz
Three-phase 220VAC; 50/60 Hz
Three-phase
220VAC; 50/60 Hz
Permissible Voltage Fluctuation
Three-phase:
170 ~ 255VAC
Single-phase: 200 ~ 255VAC
Three-phase: 170 ~ 255VAC
Single-phase: 200 ~ 255VAC
Three-phase: 170 ~ 255VAC
Single-phase: 200 ~ 255VAC
Three-phase: 170 ~ 255VAC
Single-phase: 200 ~ 255VAC
Three-phase: 170 ~ 255VAC
Single-phase:
200 ~ 255VAC
Three-phase: 170 ~ 255VAC
Three-phase:
170 ~ 255VAC
Convection
Fan Cooling
Fan Cooling
Fan Cooling
Fan Cooling
Cooling System
Convection
Convection
Electronic Gear Ratio
Gear Ratio = N/M where N: 1~32767, M: 1:32767 (1/50<N/M<200)
Gear Ratio = N/M Gear Ratio = N/M Gear Ratio = N/M Gear Ratio = N/M Gear Ratio = N/M Electronic gear N/M
where N: 1~32767, where N: 1~32767, where N: 1~32767, where N: 1~32767, where N: 1~32767, multiple N: 1~32767,
M: 1:32767 M: 1:32767 M: 1:32767 M: 1:32767 M: 1:32767 M: 1:32767
(1/50<N/M<200)(1/50<N/M<200)(1/50<N/M<200)(1/50<N/M<200)(1/50<N/M<200)(1/50<N/M<200)
Amplifier
Permissible Frequency Fluctuation
50 / 60 Hz +/-5%
Resolution/Quadrature Feedback Counts
2500 ppr /10000 cpr
Control Modes
Position/Velocity/Torque
Dynamic Brake
Built-in
Position Control Mode:
Maximum Input Pulse Frequency
Pulse Type
Command Source
Torque Limit Operation
Feed Forward Compensation
500KPPS (Line Driver) / Maximum 200KPPS (Open Collector)
Pulse/Direction;
CW/CCW;
A/B Phase
External pulse train/ Internal parameters
Yes
Yes
Analog Commands: Voltage Range
0 to +/-10 VDC
Torque and Velocity Control Mode Command Source
External analog signal / Discrete set points stored by internal parameters
Speed Control Range
1:5000
Speed Control Frequency Response
Maximum 450 Hz
Torque Control Mode Permissible Time for Overload
8 seconds under 200% rated output
Communications Interface
RS-232 / RS-485 /RS-422
Environmental
Altitude
Altitude 1000 meters above sea level or lower
Operating Temperature
0 to 55°C (Forced cooling for operation above 55°C)
Storage Temperature
-20°C to 65°C
Humidity
0 to 90% (Non condensing)
Vibration
<20 Hz: 9.8 m/sec/sec (1G); 20 to 50 Hz: 5.88 m/sec/sec (0.6 G)
Standards
CE (IEC/EN 61800-5-1), UL/cUL (508C), TUV, C-tick
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.19
Servo Amplifiers
Motion Control Systems
VersaMotion
Dimensions
IC800VMA012, IC800VMA022, IC800VMA042
70
162
159
150
Ø6
75
69
64
140
LABEL
LABEL
PE
TERMINAL
69
SCREW: M4x 0.7
MOUNTING SCREW TORQUE: 14(kgf-cm)
Dimensions shown in mm
IC800VMA072, IC800VMA102
93
83
64
191
70
149
162
Ø6
LABEL
LABEL
73
PE
TERMINAL
SCREW: M4x 0.7
MOUNTING SCREW TORQUE: 14(kgf-cm)
Dimensions shown in mm
5.20
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Amplifiers
VersaMotion
Dimensions
IC800VMA202, IC800VMA302
LABEL
245
206
70
229
110
91
LABEL
SCREW: M4x 0.7
MOUNTING SCREW TORQUE: 14(kgf-cm)
Dimensions shown in mm
Optional Cable and Terminal Block
50.7
86.8
500
146.4
www.ge-ip.com
Dimensions shown in mm
GE Intelligent Platforms Control Systems Solutions
5.21
Servo Amplifiers
Motion Control Systems
VersaMotion
PT Diagrams
STANDARD CONNECTION
Connection
Position Control Mode - Pulse Follower Mode
S e rvo D rive
MC C B
A C 220/230V
S ingle -phas e
or T hre e -phas e
50/60H z
R e ge ne rative
R e s is tor
MC
R
S
T
P
D
C
L1
L2
S IG N
/S IG N
P ULS E
/P U L S E
T -R E F
G ND
P uls e Input
( L ine D rive r)
( N ote 1)
10V
37
36
41
43
18
13
U
C N1
V
W
FG
C N2
D C 24V
C O M+
11
C O M-
45, 47, 49
B lack
G re e n
E ncode r
5
A
4
/A
7
B
9
/B
14, 16
/Z
9
D I2
10
T C M0
D I3
34
16
T C M1
D I4
8
12, 13, 19 G N D
AR S T
D I5
33
15
C WL
D I6
32
C C WL
D I7
31
21 O A
E MG S
D I8
30
22 /O A
25 O B
ZSPD
1. 5K
24V
HOME
1. 5K
TPOS
1. 5K
ALRM
SG
13, 15 G N D
D I1
1. 5K
E ncode r W iring
+ 5V
S ON
SRDY
T wis te d-pair or
twis te d-s hie ld
cable
Z
2
C C LR
1. 5K
5.22
17
S e rvo
M otor
W hite
10
C N1
VDD
R ed
SG
C N1
A B lack
/A B lack /R e d
B W hite
/B W hite /R e d
Z O range
/Z O range /R e d
+ 5V B rown & B rown/W hite
G N D B lue & B lue /W hite
A
MO N1
A
MO N2
10K
10K
C N1
C N1
D O 1+
7
D O 1-
6
D O 2+
5
D O 2-
4
D O 3+
3
D O 3-
2
D O 4+
1
D O 4-
26
D O 5+
28
D O 5-
27
GE Intelligent Platforms Control Systems Solutions
23 /O B
50 O Z
24 /O Z
M ax. allowable
curre nt 200mA
voltage 40V
C N3
48 O C Z
13 G N D
A phas e puls e
B phas e puls e
P G D ividing
R atio O utput
Z phas e puls e
Z phas e ope n colle ctor
6 R S 422T 5 R S 422T +
4 R S 422R - & R S 232_ R X
3 R S 422R +
2 R S 232_ T X
1 R S 232_ G N D
www.ge-ip.com
Motion Control Systems
Servo Amplifiers
VersaMotion
Connection PR
Diagrams
STANDARD CONNECTION
Position Control Mode - Stored Position Commands Mode
MC C B
S e rvo D rive
MC
A C 220/230V
S ingle -phas e
or T hre e -phas e
50/60H z
R e ge ne rative
R e s is tor
R
S
T
P
D
C
L1
L2
U
V
C N1
T -R E F
G ND
10V
W
18
13
FG
C N2
VCC
20
D C 24V
VDD
17
C O M+
11
R ed
S e rvo
M otor
W hite
B lack
E ncode r
G re e n
5
A
4
/A
7
B
9
/B
10
C N1
/Z
45, 47, 49
D I1
9
CTRG
D I2
10
POS0
D I3
34
POS1
D I4
8
16
SG
C N1
AR S T
D I5
33
C WL
D I6
32
15
C C WL
D I7
31
E MG S
D I8
30
ZSPD
1. 5K
24V
HOME
1. 5K
TPOS
1. 5K
ALRM
/B W hite /R e d
Z O range
/Z O range /R e d
+ 5V B rown & B rown/W hite
G N D B lue & B lue /W hite
A
MO N1
12, 13, 19 G N D
1. 5K
SG
14, 16 + 5V
13, 15 G N D
C O M-
SRDY
E ncode r W iring
A B lack
/A B lack /R e d
B W hite
Z
2
S ON
1. 5K
T wis te d-pair or
twis te d-s hie ld
cable
A
MO N2
10K
10K
C N1
C N1
21 O A
22 /O A
A phas e puls e
B phas e puls e
D O 1+
7
25 O B
23 /O B
D O 1-
6
50 O Z
D O 2+
5
24 /O Z
D O 2-
4
D O 3+
3
D O 3-
2
D O 4+
1
D O 4-
26
D O 5+
28
D O 5-
27
M ax. allowable
curre nt 200mA
voltage 40V
C N3
48 O C Z
13 G N D
P G D ividing
R atio O utput
Z phas e puls e
Z phas e ope n colle ctor
6 R S 422T 5 R S 422T +
4 R S 422R - & R S 232_ R X
3 R S 422R +
2 R S 232_ T X
1 R S 232_ G N D
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.23
Servo Amplifiers
Motion Control Systems
VersaMotion
S STANDARD
Connection
DiagramsCONNECTION
Speed Control Mode
MC C B
R e ge ne rative
R e s is tor
S e rvo D rive
MC
A C 220/230V
S ingle -phas e
or T hre e -phas e
50/60H z
R
S
T
P
D
C
L1
L2
U
V
C N1
10K
V -R E F
G ND
T -R E F
G ND
10V
10K
VCC
W
42
13
FG
C N2
18
13
20
D C 24V
R ed
W hite
B lack
S e rvo
M otor
G re e n
E ncode r
5
A
4
/A
7
B
9
/B
10
C N1
/Z
VDD
17
C O M+
11
C O M-
45, 47, 49
S ON
D I1
9
TR QLM
D I2
10
S P D0
D I3
34
S P D1
D I4
8
12, 13, 19 G N D
AR S T
D I5
33
15
C WL
D I6
32
C C WL
D I7
31
E MG S
D I8
30
1. 5K
SRDY
1. 5K
ZSPD
1. 5K
24V
TSPD
1. 5K
BRKR
1. 5K
ALRM
E ncode r W iring
A B lack
/A B lack /R e d
B W hite
Z
2
14, 16
T wis te d-pair or
twis te d-s hie ld
cable
SG
/B W hite /R e d
Z O range
+ 5V
13, 15 G N D
/Z O range /R e d
+ 5V B rown & B rown/W hite
G N D B lue & B lue /W hite
SG
C N1
16
A
MO N1
A
MO N2
10K
10K
C N1
C N1
21 O A
22 /O A
A phas e puls e
25 O B
23 /O B
B phas e puls e
50 O Z
24 /O Z
Z phas e puls e
48 O C Z
13 G N D
Z phas e ope n colle ctor
D O 1+
7
D O 1-
6
D O 2+
5
D O 2-
4
D O 3+
3
D O 3-
2
D O 4+
1
D O 4-
26
5 R S 422T +
D O 5+
28
4 R S 422R - & R S 232_ R X
D O 5-
27
3 R S 422R +
M ax. allowable
curre nt 200mA
voltage 40V
C N3
P G D ividing
R atio O utput
6 R S 422T -
2 R S 232_ T X
1 R S 232_ G N D
5.24
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Amplifiers
VersaMotion
Connection
Diagrams CONNECTION
T STANDARD
Torque Control Mode
MC C B
A C 220/230V
S ingle -phas e
or T hre e -phas e
50/60H z
R e ge ne rative
R e s is tor
S e rvo D rive
MC
R
S
T
P
D
C
L1
L2
U
V
C N1
10K
V -R E F
G ND
T -R E F
G ND
10V
10K
VCC
W
42
13
FG
C N2
18
13
20
D C 24V
C N1
R ed
S e rvo
M otor
W hite
B lack
E ncode r
G re e n
A
4
/A
7
B
9
/B
10
Z
/Z
2
14, 16 + 5V
13, 15 G N D
VDD
17
C O M+
11
C O M-
45, 47, 49
S ON
D I1
9
S P DLM
D I2
10
16
T C M0
D I3
34
12, 13, 19 G N D
T C M1
D I4
8
15
AR S T
D I5
33
C WL
D I6
32
C C WL
D I7
31
E MG S
D I8
30
1. 5K
SRDY
1. 5K
ZSPD
1. 5K
24V
TSPD
1. 5K
BRKR
1. 5K
ALRM
www.ge-ip.com
T wis te d-pair or
twis te d-s hie ld
cable
5
E ncode r W iring
SG
A B lack
/A B lack /R e d
B W hite
/B W hite /R e d
Z O range
/Z O range /R e d
+ 5V B rown & B rown/W hite
G N D B lue & B lue /W hite
SG
C N1
A
MO N1
A
MO N2
10K
10K
C N1
7
D O 1-
6
D O 2+
5
D O 2-
4
D O 3+
3
D O 3-
2
D O 4+
1
D O 4-
26
D O 5+
28
D O 5-
27
A phas e puls e
25 O B
23 /O B
B phas e puls e
50 O Z
C N1
D O 1+
21 O A
22 /O A
24 /O Z
48 O C Z
13 G N D
P G D ividing
R atio O utput
Z phas e puls e
Z phas e ope n colle ctor
M ax. allowable
curre nt 200mA
voltage 40V
C N3
6 R S 422T 5 R S 422T +
4 R S 422R - & R S 232_ R X
3 R S 422R +
2 R S 232_ T X
1 R S 232_ G N D
GE Intelligent Platforms Control Systems Solutions
5.25
Servo Amplifiers
Motion Control Systems
VersaMotion
Ordering Information
Model VersaMotion 100 Watt
Motor Part Number
Motor/Brake Part Number
Amplifier Part Number
VersaMotion
200 Watt
VersaMotion 400 Watt
VersaMotion
750 Watt
IC800VMM01LNKSE25 IC800VMM02LNKSE25 IC800VMM04LNKSE25 IC800VMM07LNKSE25
N/A
IC800VMM02LBKSE25 IC800VMM04LBKSE25 IC800VMM07LBKSE25
IC800VMA012
IC800VMA022
IC800VMA042
IC800VMA072
Cables
Power Cable
Brake and Power Cable
Encoder Cable
3 m
5 m
10 m
20 m
3 m
5 m
10 m
20 m
3 m
5 m
10 m
20 m
IC800VMCP030
IC800VMCP050
IC800VMCP100 IC800VMCP200
N/A
N/A
N/A
N/A
IC800VMCE030
IC800VMCE050
IC800VMCE100
IC800VMCE200
IC800VMCP030
IC800VMCP050
IC800VMCP100 IC800VMCP200
IC800VMCB030
IC800VMCB050
IC800VMCB100
IC800VMCB200
IC800VMCE030
IC800VMCE050
IC800VMCE100
IC800VMCE200
IC800VMCP030
IC800VMCP050
IC800VMCP100 IC800VMCP200
IC800VMCB030
IC800VMCB050
IC800VMCB100
IC800VMCB200
IC800VMCE030
IC800VMCE050
IC800VMCE100
IC800VMCE200
IC800VMCP030
IC800VMCP050
IC800VMCP100
IC800VMCP200
IC800VMCB030
IC800VMCB050
IC800VMCB100
IC800VMCB200
IC800VMCE030
IC800VMCE050
IC800VMCE100
IC800VMCE200
3 m
1 m
3 m
IC800VMCS030
IC800VMCI010
IC800VMCI030
IC800VMCS030
IC800VMCI010
IC800VMCI030
IC800VMCS030
IC800VMCI010
IC800VMCI030
IC800VMCS030
IC800VMCI010
IC800VMCI030
Communications & I/O Interface Cables
Communications Cable
Flying lead I/O interface Cable
Amplifier Connectors
CN1 I/O Connector (Note 1) IC800VMACONCN1IC800VMACONCN1IC800VMACONCN1IC800VMACONCN1
CN2 Encoder Connector (Note 2) IC800VMACONCN2IC800VMACONCN2IC800VMACONCN2IC800VMACONCN2
CN3 Communication Connector (Note 3) IC800VMACONCN3IC800VMACONCN3IC800VMACONCN3IC800VMACONCN3
AC Power Connector (Note 4) IC800VMACONACPIC800VMACONACPIC800VMACONACPIC800VMACONACP
Motor Power Connector (Note 4)
IC800VMACONMTRPIC800VMACONMTRPIC800VMACONMTRPIC800VMACONMTRP
External Braking Resistor Connector (Note 4)
IC800VMADBR001 IC800VMADBR001 IC800VMADBR001 IC800VMADBR001
Motor Connectors
Power Connector (motor only)
Power Connector (motor & brake)
Encoder Connector
IC800VMMCONP001
N/A
IC800VMMCONE001
IC800VMMCONP001
IC800VMMCONP002
IC800VMMCONE001
IC800VMMCONP001
IC800VMMCONP002
IC800VMMCONE001
IC800VMMCONP001
IC800VMMCONP002
IC800VMMCONE001
Accessories
I/O Terminal Breakout Board and Cable (Note 5) 0.5 m
IC800VMTBC005
IC800VMTBC005
IC800VMTBC005
IC800VMTBC005
External Braking Resistor (Note 6) IC800VMBR040IC800VMBR040IC800VMBR040IC800VMBR040
40Ω, 400 Watt
External Braking Resistor (Note 6) IC800VMBR020IC800VMBR020IC800VMBR020IC800VMBR020
20Ω, 1000 Watt
1)The CN1 connector is only required when the I/O breakout terminal board (IC800VMTBC005) or flying lead I/O interface cable (IC800VMCI0xx) are not used for wiring access to the amplifier I/O points.
2)The CN2 encoder connector is part of the separately ordered GE feedback cable. This connector is only required when user will manufacture their own motor feedback cable.
3)The CN3 communication connector is part of the separately ordered GE serial communication cable (IC800VMCS030). This connector is only required when user will manufacture their own
communication cable.
4)These connectors are shipped with each VersaMotion amplifier (100W to 1 kW) and are only necessary to replace lost or damaged connector mates. Amplifiers rated 2 kW and larger have fixed
wiring terminals and do not use a plug-on connector mate.
5)The optional breakout terminal board provides screw terminations for wiring each I/O point on the amplifier CN1 I/O connector. The flying lead I/O interface cable (IC800VMCI0xx) or CN1 connector
(IC800VMACONCN1) may be used.
6) The optional external braking resistors are used to dissipate excessive renenerated energy during fast deceleration of large loads from high speeds.
5.26
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Amplifiers
VersaMotion
Ordering Information (continued)
Model Motor Part Number
Motor/Brake Part Number
Amplifier Part Number
VersaMotion 1000 Watt
VersaMotion
2000 Watt
IC800VMM10LNKSE25
IC800VMM20LNKSE25
IC800VMM10MNKSE25IC800VMM20MNKSE25
IC800VMM10LBKSE25
IC800VMM20LBKSE25
IC800VMM10MBKSE25IC800VMM20MBKSE25
IC800VMA102
IC800VMA202
VersaMotion
3000 Watt
IC800VMM30MNKSE25
IC800VMM30MBKSE25­­­
IC800VMA302
Cables
Power Cable
Brake and Power Cable
Encoder Cable
3 m
IC800VMCP1030
IC800VMCP2030
IC800VMCP3030
5 m
IC800VMCP1050IC800VMCP2050IC800VMCP3050
10 m
IC800VMCP1100IC800VMCP2100IC800VMCP3100
20 m
IC800VMCP1200IC800VMCP2200IC800VMCP3200
3 m
IC800VMCB1030
IC800VMCB2030
IC800VMCB3030
5 m
IC800VMCB1050IC800VMCB2050IC800VMCB3050
10 m
IC800VMCB1100IC800VMCB2100IC800VMCB3100
20 m
IC800VMCB1200IC800VMCB2200IC800VMCB3200
3 m
IC800VMCE1030
IC800VMCE1030
IC800VMCE1030
5 m
IC800VMCE1050IC800VMCE1050IC800VMCE1050
10 m
IC800VMCE1100IC800VMCE1100IC800VMCE1100
20 m
IC800VMCE1200IC800VMCE1200IC800VMCE1200
Communications & I/O Interface Cables
Communications Cable
Flying lead I/O interface Cable
3 m
IC800VMCS030
IC800VMCS030
IC800VMCS030
1 m
IC800VMCI010
IC800VMCI010
IC800VMCI010
3 m
IC800VMCI030IC800VMCI030IC800VMCI030
Amplifier Connectors
CN1 I/O Connector
CN2 Encoder Connector
CN3 Communication Connector
AC Power Connector
Motor Power Connector
External Braking Resistor Connector
IC800VMACONCN1
IC800VMACONCN2
IC800VMACONCN3
IC800VMACONACP
IC800VMACONMTRP
IC800VMADBR001
IC800VMACONCN1
IC800VMACONCN2
IC800VMACONCN3
N/A
N/A
N/A
IC800VMACONCN1
IC800VMACONCN2
IC800VMACONCN3
N/A
N/A
N/A
Motor Connectors
Power Connector (motor only)
IC800VMMCONP003
IC800VMMCONP003
IC800VMMCONP004
Power Connector (motor & brake)
IC800VMMCONP003
IC800VMMCONP003
IC800VMMCONP004
Encoder Connector IC800VMMCONE002IC800VMMCONE002IC800VMMCONE002
Accessories
I/O Terminal Breakout Board and Cable 0.5 m
External Braking Resistor
40Ω, 400 Watt
External Braking Resistor
20Ω, 1000 Watt
www.ge-ip.com
IC800VMTBC005
IC800VMBR040
IC800VMTBC005
IC800VMBR040
IC800VMTBC005
IC800VMBR040
IC800VMBR020
IC800VMBR020
IC800VMBR020
GE Intelligent Platforms Control Systems Solutions
5.27
Servo Amplifiers
Motion Control Systems
VersaMotion
Motor Specifications
Feature
VersaMotion Series
Cont. Stall Torque Range (In-lb (Nm))
2.83-126 (0.32-14.3)
Cont. Speed Range (RPM)
1500 – 3000
Max. Speed Range (RPM)
3000 – 5000
Compatible Amplifiers
VersaMotion Series
Compatible Controllers
DSM314
MountingMetric
Shaft Configuration
Straight/Keyway
Brushless Construction
Yes
Optional Brake
24 VDC
Feedback Type
Incremental Encoder
Feedback Resolution (Counts/rev)
10,000
Absolute Feedback
No
Amplifier Line Voltage
200-255 VAC 1φ
(100 W to 1 kW);
170-255 VAC 3φ
Shaft Seal
Standard
Protection Rating
IP65
InertiaLow/Medium
Motor Part Numbers
IC800VMM
30
L
B
K
Rated Power
01– 100 Watts
02– 200 Watts
04– 400 Watts
07– 750 Watts
10– 1000 Watts
20– 2000 Watts
30–­ 3000 Watts
S
E25
Feedback
E25– 2500 PPR Incremental Encoder
Shaft Seal
S– Shaft Oil Seal
Key
K– Shaft Key
Brake
N– No brake
B– 24 VDC Brake (except 100 Watt Motor)
Inertia
L– Low Inertia
M– Medium Inertia
5.28
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Amplifiers
VersaMotion Servo Motors
Specifications
Specifications
IC800VMM01LIC800VMM02LIC800VMM04LIC800VMM07L
Product Name
VersaMotion 100 Watt
VersaMotion 200 Watt
VersaMotion 400 Watt
VersaMotion 750 Watt
Rated Output (kW) 0.10.20.40.75
Rated Torque (Nm) 0.320.641.272.39
Maximum Torque (Nm)
0.961.923.827.16
Rated Speed (RPM)
3000300030003000
Maximum Speed (RPM)5000500050005000
Rated Current (Amps)
0.91.552.65.1
Maximum Current (Amps)
2.74.657.815.3
0.0370.1770.2771.13
Rotor Moment of Inertia (Kg.m2 x 10-4)
Mechanical Time Constant (msec)
0.750.8 0.530.63
Torque Constant - KT (Nm/A)
0.360.410.490.47
Voltage Constant - KE (mV/rpm)
13.616 17.417.2
Armature Resistance (Ohm)
9.3 2.791.550.42
Armature Inductance (mH)24
10.84
6.84
3.53
Electrical Time Constant (msec)
2.583.894.438.37
Maximum Radial Shaft Load (Newton)
78.4196196245
Maximum Thrust Shaft Load (Newton)
39.2
686898
Amplifier Model
IC800VMA012 IC800VMA022 IC800VMA042 IC800VMA072
Motor Technical Data
Insulation Class
Class B
Insulation Resistance
>100M ohm, 500 VDC
Insulation Strength
1500 VAC, 50Hz, 60 seconds
Vibration Grade (um)15
Brake Power (VDC)24
Vibration2.5G
IP Rating
IP65 (except shaft and connector)
Environmental Specifications
Relative Humidity
20~90%RH (non condensing)
Operating Temperature
0 to 40°C
Storage Temperature
-10 to 80°C
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.29
Servo Amplifiers
Motion Control Systems
VersaMotion Servo Motors
Specifications (continued)
Specifications
IC800VMM10L IC800VMM10M IC800VMM20L IC800VMM20MIC800VMM30M
Product Name
VersaMotion 1000 Watt
VersaMotion 1000 Watt
VersaMotion 2000 Watt
VersaMotion 2000 Watt
VersaMotion 3000 Watt
Rated Output (kW)
1.0
1.0
2.0
2.0
3.0
Rated Torque (Nm)
3.18
4.77
6.37
9.55
14.32
Maximum Torque (Nm)
9.54
14.32
19.11
28.66
42.96
Rated Speed (RPM)
3000
2000
3000
2000
2000
Maximum Speed (RPM)
5000
3000
5000
3000
3000
Rated Current (Amps)
7.3
5.6
11.3
11.0
16.1
21.9
24.9
33.9
33.0
48.3
Maximum Current (Amps)
Rotor Moment of Inertia (Kg.m x 10 )2.65
9.14
4.45
15.88
55
Mechanical Time Constant (msec)
0.74
1.64
0.66
1.05
1.06
Torque Constant - KT (Nm/A)
0.44
0.85
0.53
0.87
0.89
Voltage Constant - KE (mV/rpm)
16.8
31.9
19.2
31.8
32
Armature Resistance (Ohm)
0.20
0.465
0.14
0.174
0.052
Armature Inductance (mH)
2.0
5.99
1.53
2.76
1.38
Electrical Time Constant (msec)
10.26
12.88
10.63
15.86
26.39
Maximum Radial Shaft Load (Newton)
490
490
490
490
1470
Maximum Thrust Shaft Load (Newton)
98
98
98
98
490
Amplifier Model
IC800VMA102
IC800VMA102
IC800VMA202
IC800VMA202­
IC800VMA302
2
-4
Motor Technical Data
Insulation Class
Class B
Insulation Resistance
>100M ohm, 500 VDC
Insulation Strength
1500 VAC, 50Hz, 60 seconds
Vibration Grade (um)15
Brake Power (VDC)24
Vibration2.5G
IP Rating
IP65 (except shaft and connector)
Environmental Specifications
Relative Humidity
20~90%RH (non condensing)
Operating Temperature
0 to 40°C
Storage Temperature
-10 to 80°C
5.30
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Amplifiers
VersaMotion Servo Motors
Speed Torque Curves
operating zone. The limit of the continuous operating zone is determined with
the motor’s ambient temperature at 20°C
and its drive current as a pure sine wave.
Actual operation is limited by the current
The curves illustrate the relationship
between motor speed and output
torque. The motor can operate continuously at any combination of speed and
torque within the prescribed continuous
IC800VMM01L (100 Watt)
3
Intermittent Operation
0.5
0.25
Intermittent Operation
1
500
1000
1500
2000
2500
3000
3500
4000
4500
0
5000
500
1000
1500
2000
4500
5000
3.6
2500
3000
5
3500
4000
4500
0
5000
500
1000
1500
2000
3000
3500
4000
4500
0
5000
900
To rq ue ( Nm)
To r qu e ( Nm)
1500
1800
900
1200
10
2100
2400
2700
0
3000
1500
1800
2100
2400
2700
3000
2700
3000
33
Intermittent Operation
22
11
Continuous Operation
1200
600
IC800VMM30M (3000 Watt)
Intermittent Operation
Continuous Operation
600
300
44
5
7.5
5000
Speed (RPM)
15
15
4500
4000
Continuous Operation
2500
20
Intermittent Operation
3500
Intermittent Operation
IC800VMM20M (2000 Watt)
IC800VMM20L (2000 Watt)
22.5
3000
7.5
Speed (RPM)
30
2500
3.75
Speed (RPM)
300
2000
11.25
Continuous Operation
2000
1500
IC800VMM10M (1000 Watt)
2.5
1500
1000
15
Intermittent Operation
Continuous Operation
1000
500
Speed (RPM)
To r q u e ( Nm)
To r q u e ( Nm)
To r q u e ( Nm)
4000
7.5
Intermittent Operation
1.8
To rq u e ( Nm)
3500
10
5.4
500
1000
1500
2000
Continuous Operation
2500
3000
Speed (RPM)
Speed (RPM)
O p e ra t i n g Ti me ( se co n d s)
3000
IC800VMM10L (1000 Watt)
IC800VMM07L (750 Watt)
3500
4000
4500
5000
0
300
600
900
1200
1500
1800
2100
2400
Speed (RPM)
Load Torque vs. Operating Time
103
102
101
100
100
2500
0
Speed (RPM)
7.2
104
Continuous Operation
Continuous Operation
Speed (RPM)
500
Intermittent Operation
2
1
0.5
Continuous Operation
0
To r q u e (Nm )
1.5
To r q u e (Nm )
To r q u e (Nm )
4
2
0.75
0
IC800VMM04L (400 Watt)
IC800VMM02L (200 Watt)
1
0
of the servo drive unit. The continuous
operating zone must be derated for
­ambient temperature above 20°C.
120
140
160
180
200
220
240
260
280
Load
Operating
Time
120%
263.8 s
140%
35.2 s
160%
17.6 s
180%
11.2 s
200%
8s
220%
6.1 s
240%
4.8 s
260%
3.9 s
280%
3.3 s
300%
2.8 s
300
Load (% rated torque)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.31
Servo Amplifiers
Motion Control Systems
VersaMotion Servo Motors
Dimensions
IC800VMM01L
MOTOR CONNECTION
C4202H00-2X2P
300±50
ENCODER CONNECTION
AMP 1-172169-9
LR
300±50
Ø Sh6
LG
LE
Ø LA
LC
0.04 M
Ø LBh7
( 52.95 )
( 44.95 )
LW
2-Ø LZ
M
0.02 M
LL
KW
0.04 M
ENCODER CONNECTION
PIN No.
FUNCTION
COLOR
1
BLK
6
A
B
Z
A
B
Z
7
DC+5V
2
3
4
5
RH
WHT
MOTOR CONNECTION
ORG
PIN No.
FUNCTION
COLOR
BLK/RED
1
U
RED
WHT/RED
2
V
WHT
ORG/RED
3
W
BLK
BRN
4
C.G.
GRN/YEL
8
GND
BLU
9
SHIELD
SHIELD
SHAFT END DETAILS
Dimensions shown mm
DimensionIC800VMM01L
LC40
LZ4.5
LA46
S8
LB30
LL100.6
LL with brake
N/A (no brake available on
100 Watt model at this time)
LR25
LE2.5
LG5
LW16
RH6.2
KW3
The boxes ( ) at the ends of the model names are for shaft type or options
(keyway, brake and oilseal)
5.32
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Amplifiers
VersaMotion Servo Motors
Dimensions
KW
IC800VMM02L, IC800VMM04L, IC800VMM07L
300 ± 50
RH
300 ± 50
LR
LE
4-ØLZ
LC
ØLBh7
LW
ØSh6
ØLA
LG
LL
Dimension
Dimensions shown mm
IC800VMM02LIC800VMM04LIC800VMM07L
LC606080
LZ5.55.56.6
LA707090
S 141419
LB505070
LL
105.5130.7138.3
LL with brake
141.6
166.8
178
LR303035
LE
333
LG7.57.58
LW202025
RH111115.5
KW
556
The boxes (
) at the ends of the model names are for shaft type or options (keyway, brake and oilseal)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.33
Servo Amplifiers
Motion Control Systems
VersaMotion Servo Motors
Dimensions
KW
IC800VMM10L, IC800VMM10M, IC800VMM20L, IC800VMM20M, IC800VMM30M
LR
LE
RH
4-ØLZ
LC
ØSh6
LW
ØLBh7
ØLA
LG
LL
Dimensions shown mm
Dimension
IC800VMM10L
IC800VMM10M
IC800VMM20­­­­­L
LC 100 130 100
LZ9 4 9
LA 115 145 115
S 22 22 22
IC800VMM20­­­­­M
IC800VMM30M
130180
4 13.5
145200
2235
LB 95 110 95 110114.3
LL
153.5 147.5 199
187.5202.1
LL with brake
192.5
216
183.5
226
LR 45 55 45
LE5 6 5
LG 12 11.5 12
LW32 36 32
RH18 18 18
KW8 8 8
The boxes (
5.34
235
5579
6 4
11.520
3663
1830
8 10
) at the ends of the model names are for shaft type or options (keyway, brake and oilseal)
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Amplifiers
VersaMotion Servo Motors
Ordering Information
Part Number
Motor Only
Description
Amplifier
IC800VMM01LNKSE25
IC800VMM02LNKSE25
IC800VMM02LBKSE25
IC800VMM04LNKSE25
IC800VMM04LBKSE25
IC800VMM07LNKSE25
IC800VMM07LBKSE25
IC800VMM10LNKSE25
IC800VMM10MNKSE25
IC800VMM10LBKSE25
IC800VMM10MBKSE25
IC800VMM20LNKSE25
IC800VMM20MNKSE25
IC800VMM20LBKSE25
IC800VMM20MBKSE25
IC800VMM30MNKSE25
IC800VMM30MBKSE25­­­
100 Watt VersaMotion Servo Motor
200 Watt VersaMotion Servo Motor
200 Watt VersaMotion Servo Motor with Brake
400 Watt VersaMotion Servo Motor
400 Watt VersaMotion Servo Motor with Brake
750 Watt VersaMotion Servo Motor
750 Watt VersaMotion Servo Motor with Brake
1000 Watt VersaMotion Servo Motor
1000 Watt VersaMotion Servo Motor
1000 Watt VersaMotion Servo Motor with Brake
1000 Watt VersaMotion Servo Motor with Brake
2000 Watt VersaMotion Servo Motor
2000 Watt VersaMotion Servo Motor
2000 Watt VersaMotion Servo Motor with Brake
2000 Watt VersaMotion Servo Motor with Brake
3000 Watt VersaMotion Servo Motor
3000 Watt VersaMotion Servo Motor with Brake
IC800VMA012
IC800VMA022
IC800VMA022
IC800VMA042
IC800VMA042
IC800VMA072
IC800VMA072
IC800VMA102
IC800VMA102
IC800VMA102
IC800VMA102
IC800VMA202
IC800VMA202
IC800VMA202
IC800VMA202
IC800VMA302
IC800VMA302
Motor Cables
See applicable amplifier section for information about the proper cables to use with
each motor.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.35
Servo Amplifiers
Motion Control Systems
αi and βi Series Servo Amplifiers
All Digital Servo Systems Offer High Performance and Reliability.
GE αi and βi Series Servo Drives, based on over five million axes installed worldwide,
offer superior reliability and performance for unprecedented mean time between
failure. The αi and βi Series Servos are available in a wide range of ratings for use
with GE PACMotion PMM335 Series motion controller.
High-Performance Serial Encoders
Standard serial encoders built into the
motors provide exceptional feedback
resolution of 64K or 128K counts per
revolution. Serial encoders support higher
resolutions at high motor velocities than
standard quadrature encoders and
are more immune to noise. An optional
battery connection provides absolute
position feedback, eliminating the need to
home the system after a power shutdown.
Reduced Tuning and Setup
There is no need for potentiometer tuning
or personality modules; little tuning is
required for properly sized drives. All drive
parameters are stored in the controller in
a standard motor database. Configuration
settings are not stored in the drive, making
it possible to replace drives with little
set-up time. Stored drive and machine
parameters are quickly transferred to
repeat production machines.
Series Motor Series Controller
Command
Interface
Continuous Torque Range
Power Supply
In-lbNm
αHVi Fiber Optic
17.7-1150 2-130
αHVi, αHVis
PMM335
Separate PSM
βi
βis
PMM335
Fiber Optic
3.5-1770.4-20Built-in
βHVi
βHVis
PMM335
Fiber Optic
17.7-1772-20
Built-in
All-Digital System
All control loops—current, velocity, and
position—are closed in the GE motion
controller. High-speed microprocessors
and/or digital signal processors (DSPs)
in the controller provide loop update
times of 250 µs. The high response servo
system can compensate for machine
design limitations, yielding faster acceleration/deceleration rates and better
responses to load changes.
Agency Approvals
Info
UL, IEC rating and CE mark compliant
For application, installation, and tuning
information, consult the Services website
at www.ge-ip.com.
All-Digital Servo Command Signals
The PACMotion PMM335 motion controllers use a high speed fiber optic command
interface to the αi and βi Series amplifiers.
With its superior noise immunity, both
of these GE digital command interfaces
allows for an increased signal to noise ratio
for improved accuracy and performance.
5.36
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Amplifiers
αi and βi Series Servo Amplifiers
System Power Requirements
Amplifier Specification
βi Series
αHVi*/βHVi Series
Voltage (-15%, +10%): 3-phase
1-phase (see below)
200-240VAC400-480VAC
220-240VAC
n/a
Frequency
50/60Hz
50/60 Hz
Allowable frequency fluctuation
±2 Hz
±2 Hz
Voltage fluctuation during
acceleration/deceleration
7% or less
7% or less
Ambient Temperature Range
0-55°C
0-55°C
Humidity (non-condensing)
90%
90%
Vibration
Less than 0.5G
Less than 0.5G
Motor Model
Max. kW Rating
β0.4/5000 is0.13
*αHVi series amplifiers use a separately mounted shared power supply.
β0.5/6000 is0.35
The 4A and 20A βi Series Servo amplifiers can be run on single phase power;
however, the lifetime of the amplifier is
reduced because of higher input and
ripple current. An AC line filter is strongly
recommended to suppress the influences
of high-frequency input line noise on the
drive power supply. If a power source
within the specified voltage range is not
available, a transformer is required. The
kVA rating of the transformer should be
equal to or greater than the sum of all
motor kW ratings. If an isolation-type
power transformer is used, an AC line
filter is not required.
β1/6000 is0.5
β2/4000 is0.5
β4/4000 is0.75
β8/3000 is1.2
β12/3000 is1.8
β22/2000 is2.5
β2/4000 HVis0.5
β4/4000 HVis0.75
β8/3000 HVis1.2
β12/3000 HVis1.8
GE offers the following line filters; transformers must be supplied by the user as required.
β22/2000 HVis2.5
α2/6000HVis1.0
α4/5000HVis1.0
Part Number
Description
Amplifier Series
ZA81L-0001-0083#3C
5.4 kW, 3-phase AC line filter
βi
α12/4000HVis2.5
ZA81L-0001-0101#C
10.5 kW, 3-phase AC line filter
βi
α22/3000HVi4.0
ZA81L-0001-0168
5.4 kW, 3-phase AC line filter
βHVi
ZA81L-0001-0169
10.5 kW, 3-phase AC line filter
βHVi
ZA81L-0001-0163
18kW, 3-phase AC line filter
PSM-11HVi, PSM-18HVi
ZA81L-0001-0164
45kW, 3-phase AC line filter
PSM-30HVi, PSM-45HVi
α8/6000HVis2.2
α22/4000HVis4.5
α30/4000HVis5.5
www.ge-ip.com
α50/3000HVis w/fan
14
α100/2500HVis11
Incoming DC Power for βi Series
Control Power Specification
The βi and βHVi Series amplifiers require a
24VDC power supply for amplifier control
power. This DC power supply must be
supplied by the user. We recommend the
GE 24VDC power supply, part number
IC690PWR024. The same external DC
power supply can be used to provide
α40/4000HVis5.5
power to multiple amplifiers as long as
the supply is rated for the total current
requirements of all of the amplifiers.
Input Voltage
24VDC (±10%)
Current Requirement (per amplifier):
βi Series
βHVi Series
0.9 amps
0.9 amps
The αHVi series power supplies require
a single phase 200-230VAC control
power input.
GE Intelligent Platforms Control Systems Solutions
5.37
Servo Amplifiers
Motion Control Systems
αHVi Series Servo Amplifiers and Power Supplies
Dimensions
The αHVi Series amplifiers and PSM-HVi power supplies are designed with a rear-mounted heat sink that extends through a hole in
the mounting plate. This design eliminates most of the heat dissipation inside the control cabinet, reducing the temperature rise in
the cabinet and the load on cabinet cooling equipment.
αHVi Amplifier Dimension Drawings
mounting flange
FANUC
mounting
mounting
flange flange
FANUCFANUC
FANUC LTDFANUC LTD
Yamenashi 401-0597 JAPAN
Yamenashi 401-0597 JAPAN
CAUTION
CAUTION
HIGHVOLTAGE
DISCHARGE
2 min
TIME
>
CAUTION
When the LED is lit
When the LED is lit
don’t touch the terminals. don’t touch the terminals.
DISCHARGE
DISCHARGE
2 Mins TIME
2 Mins
TIME
STATUS
>
>
STATUS
STATUS
ENCODER
BATTERY
CX5X
AC
200-240 V
50/60 Hz
CX5X
CX5X
AC
200-240 V
50/60 Hz
BATTERY
COP10B
360 (14.17)
CXA2A
380
360 (14.96)
(14.17)
CX1A CX1B
380 (14.96)
360 (14.17)
380 (14.96)
CXA2B
CX1A CX1B
CXA2B
CXA2B
CXA2A
CXA2A
COP10B
COP10B
COP10A
COP10A
COP10A
JX5
ENC1
JF1
JX5
JX5
ENC1
JF1
ENC1
JF1
CX8
DBI
CX9
DBC
CX8
DBI
CX9
DBC
UVW UVW
Front view of
αSVM1-180HVi
5.38
11
338 (13.31)
360 (14.17)
11
(0.43)
100 (3.94)
100 max.
(3.94) max.
(0.43)
360 (14.17)
11
(0.43)
338 (13.31)
11
172 (6.77)
172 (6.77)
(0.43)
360 (14.17)
11
(0.43)
11
(0.43)
338 (13.31)
360 (14.17)
11
(0.43)
360 (14.17)
(0.43)
360 (14.17)
150 (5.90)
150 (5.90)100 (3.94) max.
11
11
2-M5
76 (2.99)
4-M5
GE Intelligent Platforms Control Systems Solutions
(0.43)
76 (2.99)
(0.43)
2-M5
46 (1.81)
11
2-M5
(0.43)
Panel cut-out for
αSVM1-180HVi
(0.43)
46 (1.81)
338 (13.31)
11
338 (13.31)
11
2-M5
172 (6.77)
60 (2.36)
Panel cut-out for
αSVM1-10HVi
αSVM1-40HVi
and αSVM1-80HVi
Side view
338 (13.31)
Front view of
αSVM1-10HVi
αSVM1-40HVi
and αSVM1-80HVi
4-M5
130 (5.12)
130 (5.12)
136 (5.35)
136 (5.35)
www.ge-ip.com
Motion Control Systems
Servo Amplifiers
αHVi Series Servo Amplifiers and Power Supplies
Dimensions
Dynamic Brake Module Dimension Drawings
T2
T2
FANUC
FANUC
FANUC LTD
FANUC LTD
T1
U
Front view of
A06B-6079-H401
V
T1
W
U
V
W
Side view
50 (1.97)
100 (3.93)
www.ge-ip.com
352 (13.86)
352 (13.86)
Yamenashi 401-0597 JAPAN
360 (14.17)
380 (14.96)
360 (14.17)
380 (14.96)
Yamenashi 401-0597 JAPAN
Dynamic Brake Module (DBM) Dynamic Brake Module (DBM)
50 (1.97)
100 (3.93)
172 (6.77)
172 (6.77)
GE Intelligent Platforms Control Systems Solutions
5.39
Servo Amplifiers
Motion Control Systems
αHVi Series Servo Amplifiers and Power Supplies
Dimensions
Power Supply Dimension Drawings
mounting mounting
flange
flange
mounting flange
FANUC
FANUC
FANUC LTD
FANUC LTD
CAUTION
>
STATUS
STATUS
STATUS
3.5A 1A
Input Output
3.5A 1A
Input Output
AC
200-240 V
50/60 Hz
AC
200-240 V
50/60 Hz
CX1A CX1B
360 (14.17)
360 (14.17)
380 (14.96)
CXA2A
JX1B
L1 L2 L3
L1 L2 L3
L1 L2 L3
Side view
11
360 (14.17)
338 (13.31)
360 (14.17)
11
(0.43)
11
(0.43)
338 (13.31)
11
(0.43)
100 (3.94) max.
150 (5.90)150 (5.90)
(0.43)
172 (6.77)
360 (14.17)
11
CX3 CX4
MCC ESP
172 (6.77)172 (6.77)
100 (3.94)100
max.
(3.94) max.
76 (2.99)
11
(0.43)
11
2-M5
76 (2.99)
(0.43)
11
Panel cut-out for
PSM-30HVi and
PSM-45HVi
(0.43)
(0.43)
11
5.40
338 (13.31)
11
(0.43)
338 (13.31)
360 (14.17)
11
(0.43)
360 (14.17)
(0.43)
360 (14.17)
338 (13.31)
11
338 (13.31)
Front view of
PSM-30HVi and
PSM-45HVi
90 (3.54)
Panel cut-out for
PSM-11HVi and
PSM-18HVi
2-M5
46 (1.81)
JX1B
CX3 CX4
MCC ESP
CX3 CX4
MCC ESP
CX1A CX1B
CXA2A
(0.43)
380 (14.96)
360 (14.17)
380 (14.96)
CXA2A
JX1B
2-M5
>
3.5A 1A
Input Output
CX1A CX1B
46 (1.81)
When the LED is lit
don’t touch the terminals.
DISCHARGE
2 Mins
TIME
>
AC
200-240 V
50/60 Hz
2-M5
Yamenashi 401-0597 JAPAN
CAUTION
When the LED is lit
don’t touch the terminals.
DISCHARGE
2 Mins
TIME
When the LED is lit
don’t touch the terminals.
DISCHARGE
2 Mins
TIME
Front view of
PSM-11HVi and
PSM-18HVi
FANUC LTD
Yamenashi 401-0597 JAPAN
Yamenashi 401-0597 JAPAN
CAUTION
FANUC
4-M5
4-M5
130 (5.12)
130 (5.12)
136 (5.35)
136 (5.35)
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Amplifiers
αHVi Series Servo Amplifiers and Power Supplies
αSVM1-10HVi, αSVM1-40HVi, αSVM1-80HVi Connection Diagram
FANUC
DC Link connection
between amplifiers
and power supply
2
1
CAUTION
HIGHVOLTAGE
DISCHARGE
2 min
TIME
>
STATUS
3
ENCODER
BATTERY
Amplifier mounted
battery for Serial
Encoder Backup.
(See note 3)
IC800ABK002
4
CX5X
E-stop, 24VDC and
serial encoder battery
input from previous
amplifier or
power supply
BATTERY
CXA2B
5
6
No.
CXA2A
7
E-stop, 24VDC and
serial encoder
battery output to
next amplifier
Fiber optic cable
to PACMotion PMM335
Motion Controller
COP10B
8
Fiber optic
command to
next amplifier
COP10A
9
10
JX5
ENC1
JF1
Name
Remarks
1
DC link terminal block
2
DC link charge LED
3
STATUS
Status LED
4
CX5X
Absolute encoder battery input
5
CXA2B
Input connector for PSM interface
6
CXA2A
Output connector for PSM interface
7
COP10B
Fiber optic servo command input
8
COP10A
Fiber optic servo command output
9
JX5
No connection
10
ENC1/JF1
Serial encoder feedback
11
CZ2
Motor power connector
12
Tapped hole for grounding the amplifier
Notes:
11
1. Always install the circuit breakers, magnetic contactor, and AC line filter.
12
power
Optional 24V power
for motor brake
(See note 2)
www.ge-ip.com
encoder
αHVi or αHVis
series motor
2. Use a regulated 24 VDC power supply for the
amplifier. 24 VDC power supply for the amplifier
and power supply for the motor brake cannot
be shared.
3. The IC800ABK001 encoder battery pack mounts
separately on the panel and can power up to 4
axes. Alternatively, the IC800ABK002 1-axis lithium
battery can be snapped onto each amplifier.
GE Intelligent Platforms Control Systems Solutions
5.41
Servo Amplifiers
Motion Control Systems
αHVi Series Servo Amplifiers and Power Supplies
αSVM1-180HVi, Connection Diagram
FANUC
DC Link connection
between amplifiers
and power supply
2
No.
1
FANUC LTD
Yamenashi 401-0597 JAPAN
CAUTION
When the LED is lit
don’t touch the terminals.
DISCHARGE
2 Mins
TIME
>
3
STATUS
Amplifier mounted
battery for serial
encoder backup.
(See note 3)
IC800ABK003
4
200VAC output to
dynamic brake
module (DBM)
terminal block T2
CX5X
AC
200-240 V
50/60 Hz
E-stop, 24VDC and
serial encoder battery
input from previous
amplifier or
power supply
5
6
200VAC input from
power supply
module CX1A
CX1A CX1B
7
CXA2B
8
CXA2A
9
E-stop, 24VDC and
serial encoder
battery output to
next amplifier
Fiber optic cable
to PACMotion PMM335
motion controller
COP10B
10
Fiber optic
command to
next amplifier
COP10A
11
JX5
12
ENC1
JF1
13
Dynamic brake
module interface
(T2 on DBM)
14
CX8
DBI
UVW
Dynamic brake
module MCC coil
control (T2 on DBM)
CX9
DBC
Optional 24V power
for motor brake
(See note 2)
5.42
αHVi or αHVis
series motor
GE Intelligent Platforms Control Systems Solutions
DC link terminal block
2
DC link charge LED
3
Status LED
STATUS
4
CX5X
Absolute
encoder battery input
5
CX1A
200VAC power supply
output connector
6
CX1B
200VAC power supply
input connector
7
CXA2B
Input connector for
PSM interface
8
CXA2A
Output connector for
PSM interface
9
COP10B
Fiber optic servo
command input
10
COP10A
Fiber optic servo
command output
11
JX5
No connection
12
ENC1/JF1
Serial encoder feedback
13
CX8
Dynamic brake module
interface connector
14
CX9
Connector for the magnetic
contactor (MCC) drive coil
of the dynamic brake module
15
Motor power connector
TB2
16
Tapped hole for grounding
the amplifier
1. Always install the circuit breakers, magnetic contactor, and AC line filter.
encoder
power
Remarks
Notes:
15
16
To motor power
terminal block T1
on Dynamic
brake module
Name
1
2. Use a regulated 24 VDC power supply
for the amplifier. 24 VDC power supply
for the amplifier and power supply for
the motor brake cannot be shared.
3. The IC800ABK001 encoder battery pack
mounts separately on the panel and
can power up to 4 axes. Alternatively,
the IC800ABK003 1-axis lithium battery
can be snapped onto each amplifier.
www.ge-ip.com
Motion Control Systems
Servo Amplifiers
αHVi Series Servo Amplifiers and Power Supplies
PSM-HVi Power Supply Connection Diagram
FANUC
DC Link connection
to amplifiers
2
1
FANUC LTD
Yamenashi 401-0597 JAPAN
CAUTION
When the LED is lit
don’t touch the terminals.
DISCHARGE
2 Mins
TIME
>
3
STATUS
3.5A 1A
Input Output
AC
200-240 V
50/60 Hz
5
4
200–240VAC 1φ
Control Power
CX1A CX1B
CXA2A
200–240VAC 1φ
output to
αSVM1-180HVi only
6
E-stop, 24VDC and
serial encoder
battery output
to amplifiers
7
JX1B
12
CX37
8
9
Circuit
Breaker
Magnetic
Contactor
E-stop contact input
from machine
CX3 CX4
MCC ESP
AC Line
Filter
No.
10
L1 L2 L3
11
www.ge-ip.com
Name
Remarks
1
DC link terminal block
2
DC link charge LED
3
STATUS
Status LED
4
CX1A
200VAC power supply input connector
5
CX1B
200VAC power supply output connector
(used with αSVM1-180HVi only)
6
CXA2A
Output connector for PSM interface
7
JX1B
Not used
8
CX3
Connector for the main magnetic contactor (MCC) drive coil control signal
9
CX4
Connector for ESP signal
10
TB2
Terminal block for main AC power line
11
Tapped hole for grounding the power supply
12
Power failure detection output
CX37
GE Intelligent Platforms Control Systems Solutions
5.43
Servo Amplifiers
Motion Control Systems
αHVi Series Servo Amplifiers and Power Supplies
αHVi System Connections
PSM-HVi
Power Supply
Module
αSVM1-180HVi
Servo Amplifier
Module
Dynamic Brake
Module
αSVM1-80HVi
Servo Amplifier
Module
(Note 4)
DC Link
Bus Bars
Control Power
200 to 240 VAC 1φ
1φ
Circuit
Breaker 2
CX1B
CX1A
CXA2A
Lightning
Surge
Protector
CX1A
CXA2B
CXA2A
CXA2B
CX8
T2
CX9
CX3
MCC
TB2
CXA2A
COP10A COP10B
COP10A COP10B
CX4
To Additional
Amplifiers
T1
TB2
CZ2
Main Power
400 to 480 VAC 3φ
Circuit
Breaker 1
Magnetic
Contactor
3φ
AC Reactor
α50HVis
3φ Fan Motor
Circuit
Breaker 3
Servo Motor
Lightning
Surge
Protector
No.
Name
Servo Motor
Remarks
1
DC Link Bus Bars
30, 60 or 90 mm long bar kits available based on width of module 2
CX1A/CX1B
200VAC 1 phase control power unit2
3
CXA2A/CXA2B
Output/input connectors for PSM interface3
4
CX3
Connector for main magnetic contactor (MCC) control signal2
5
CX4
E-Stop signal connector2
6
COP10A/COP10B
Fiber optic command cable
1
Part Numbers
60 mm kit: Z44A718031-G05
90 mm kit: Z44A718031-G03
150 mm kit: Z44A718031-G12
ZA06B-6071-K203 (PSM connector kit)
ZA02B-0120-K321 (2 required for αSVM1-180HVi only)
ZA06B-6110-K210 (connector: 2 required)
Z44C746453-001 (200 mm cable for shared
encoder battery)
Z44C746453-002 (200 mm cable for built-in
encoder battery or no battery backup)
ZA06B-6071-K203 (PSM connector kit)
ZA06B-6071-K203 (PSM connector kit)
See page 17 for cable options
Notes:
1. Power supply and amplifier kits include appropriate length DC link bus bars.
2. T he power supply connector kit included with all power supply module kits includes connectors for CX1A, CX3 and CX4. Each
αSVM1-180HVi amplifier kit includes two of the CX1A/B connectors to jumper the 200VAC single phase power from the power
supply module.
3. T he PSM interface on connectors CXA2A/B supplies 24VDC power from the PSM power supply module to the connected amplifiers.
Additionally, this interface allows shared signals such as system emergency stop and battery backup for the motor serial encoders. Connectors are included in the amplifier and power supply kits. Prefabricated cables are also available. Select the correct cable
based on the battery type used to backup the motor serial encoder feedback for absolute positioning.
4. Position of dynamic brake module is for reference only. Normally this module is mounted above or below the amplifiers or at
the end of the module line up so that the standard DC link bus bar length is adequate to make the link connection between
adjacent amplifiers.
5.44
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Amplifiers
αHVi Series Servo Amplifiers and Power Supplies
Ordering Information
The αHVi series amplifiers and PSM-HVi power supply modules
can be ordered as individual components or as kits that include
connectors, spare fuses, and DC link bus bars. The kits are
recommended for new installations while spare parts and
replacement units should use the part number for the amplifier
or power supply module. To place an order for a complete
system, select the servo motor(s) that meet your application
requirements, then select the amplifier kit(s), power supply kit,
cables, connectors and accessories.
αHVi Amplifier Kits
Part Number
Kit Description
IC800AIHV010
10 Amp αHVi Series Amplifier Package
IC800AIHV040
40 Amp αHVi Series Amplifier Package
IC800AIHV080 80 Amp αHVi Series Amplifier Package
IC800AIHV180
180 Amp αHVi Series Amplifier Package
Qty.
1
1
2
1
1
1
1
2
1
1
1
1
2
1
1
1
1
2
1
1
2
Kit Contents
αSVM1-10HVi FSSB Amplifier (ZA06B-6127-H102)
SVM Spare Control Power Fuse (ZA06B-6073-K250)
CXA2A/B Connector (ZA06B-6110-K210)
CZ2 Motor Power Output Connector (ZA06B-6110-K203#ZZM)
Bus Bar Kit for 60 mm Module (Z44A718031-G05)
αSVM1-40HVi FSSB Amplifier (ZA06B-6127-H104)
SVM Spare Control Power Fuse (ZA06B-6073-K250)
CXA2A/B Connector (ZA06B-6110-K210)
CZ2 Motor Power Output Connector (ZA06B-6110-K203#ZZM)
Bus Bar Kit for 60 mm Module (Z44A718031-G05)
αSVM1-80HVi FSSB Amplifier (ZA06B-6127-H105)
SVM Spare Control Power Fuse (ZA06B-6073-K250)
CXA2A/B Connector (ZA06B-6110-K210)
CZ2 Motor Power Output Connector (ZA06B-6110-K203#ZZM)
Bus Bar Kit for 60 mm Module (Z44A718031-G05)
αSVM1-180HVi FSSB Amplifier (ZA06B-6127-H106)
SVM Spare Control Power Fuse (ZA06B-6073-K250)
CXA2A/B Connector (ZA06B-6110-K210)
CX8/CX9 DB Module Interface Connector Kit (ZA06B-6073-K216)
Bus Bar Kit for 150 mm Module (Z44A718031-G12)
CX1A/B Control Power Connector Kit (ZA02B-0120-K321)
Qty.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Kit Contents
PSM-11HVi 11 kW HV Power Supply Module (ZA06B-6150-H011)
Spare Control Power Fuse (ZA06B-6077-K250)
Bus Bar Kit for 90 mm Module (Z44A718031-G03)
Power Supply Connector Kit (ZA06B-6071-K203)
PSM-18HVi 18 kW HV Power Supply Module (ZA06B-6150-H018)
Spare Control Power Fuse (ZA06B-6077-K250)
Bus Bar Kit for 90 mm Module (Z44A718031-G03)
Power Supply Connector Kit (ZA06B-6071-K203)
PSM-30HVi 30 kW HV Power Supply Module (ZA06B-6150-H030)
Spare Control Power Fuse (ZA06B-6077-K250)
Bus Bar Kit for 150 mm Module (Z44A718031-G12)
Power Supply Connector Kit (ZA06B-6071-K203)
PSM-45HVi 45 kW HV Power Supply Module (ZA06B-6150-H045)
Spare Control Power Fuse (ZA06B-6077-K250)
Bus Bar Kit for 150 mm Module (Z44A718031-G12)
Power Supply Connector Kit (ZA06B-6071-K203)
PSM-HVi Power Supply Kits
Part Number
Kit Description
IC800PSHV011
11 kW Power Supply Module Package
IC800PSHV018
18 kW Power Supply Module Package
IC800PSHV030 30 kW Power Supply Module Package
IC800PSHV045
45 kW Power Supply Module Package
The αHVi series amplifiers use a separately mounted shared power supply for one or more axes. These power supplies can
regenerate energy back to the AC line so no regenerative resistors or modules are required.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.45
Servo Amplifiers
Motion Control Systems
αHVi Series Amplifier and Motor
Ordering Information
Motor Model
α2/6000HVis
α4/5000HVis
Motor Part Number
ZA06B-0219-B200
ZA06B-0216-B200
Motor/Brake Part Number
ZA06B-0219-B500
ZA06B-0216-B500
Beta Amplifier Model
βSVM1-10HVi
βSVM1-10HVi
Beta Amplifier Part Number
ZA06B-6131-H001
ZA06B-6131-H001
n/an/a
Beta Amplifier Fan Kit (Note1)
Beta Amplifier Kit
IC800BIHV010
IC800BIHV010
Alpha Amplifier Model
αSVM1-10HVi
αSVM1-10HVi
Alpha Amplifier Part Number
ZA06B-6127-H102
ZA06B-6127-H102
Alpha Amplifier Kit
IC800AIHV010
IC800AIHV010
Cables
α2/6000HVis
α4/5000HVi
Power Cable
Power Cable (Shielded)
Feedback Cable (Right Angle)
Feedback Cable (Straight)
Brake Power Cable
PSM Interface Cable (External Battery)
PSM Interface Cable (Built-in or No Battery)
Fiber Optic Command Cable
Fiber Optic Cable (Sheathed)
7 M
CP2I-0WPB-0070-AZ 14 M
CP2I-0WPB-0140-AZ 7 M
CP2I-0WEB-0070-AZ
14 M
CP2I-0WEB-0140-AZ
7 M
CFDA-7WPB-0070-AZ
14 M
CFDA-7WPB-0140-AZ
7 M
CFDA-0WPB-0070-AZ
14 M
CFDA-0WPB-0140-AZ
Integrated with power cable
7 M
Integrated with power cable
14 M
200 mm
Z44C746453-001 200 mm
Z44C746453-002
15 CM
30 CM
1 M
2 M
3 M
1 M
3 M
5 M
10 M
20 M
30 M
50 M
100 M
Connector Kits
α2/6000HVis
α8/6000HVis
ZA06B-0233-B200
ZA06B-0233-B500
βSVM1-40HVi
ZA06B-6131-H003
ZA06B-6134-K002
IC800BIHV040
αSVM1-40HVi
ZA06B-6127-H104
IC800AIHV040
α8/6000HVis
CP2I-0WPB-0070-AZ CP3I-0WPB-0070-AZ
CP2I-0WPB-0140-AZ CP3I-0WPB-0140-AZ
CP2I-0WEB-0070-AZ
CP3I-0WEB-0070-AZ
CP2I-0WEB-0140-AZ
CP3I-0WEB-0140-AZ
CFDA-7WPB-0070-AZ
CFDA-7WPB-0070-AZ
CFDA-7WPB-0140-AZ
CFDA-7WPB-0140-AZ
CFDA-0WPB-0070-AZ
CFDA-0WPB-0070-AZ
CFDA-0WPB-0140-AZ
CFDA-0WPB-0140-AZ
Integrated with power cableCB4N-0WPM-0070-AZ
Integrated with power cableCB4N-0WPM-0140-AZ
Z44C746453-001
Z44C746453-001
Z44C746453-002
Z44C746453-002
ZA66L-6001-0023#L150R0
ZA66L-6001-0023#L300R0
ZA66L-6001-0023#L1R003
ZA66L-6001-0023#L2R003
ZA66L-6001-0023#L3R003
ZA66L-6001-0026#L1R003
ZA66L-6001-0026#L3R003
ZA66L-6001-0026#L5R003
ZA66L-6001-0026#L10R03
ZA66L-6001-0026#L20R03
ZA66L-6001-0026#L30R03
ZA66L-6001-0026#L50R03
ZA66L-6001-0026#L100R3
α4/5000HVi
α8/6000HVis
Encoder Feedback Connector (JF1)
ZA06B-6073-K214
ZA06B-6073-K214
ZA06B-6073-K214
CXA2A/B Jumper Connector (2 Req)
ZA06B-6110-K210
ZA06B-6110-K210
ZA06B-6110-K210
CZ2 Motor Power Output Connector
ZA06B-6110-K203#ZZM
ZA06B-6110-K203#ZZM
ZA06B-6110-K203#ZZM
Motor Half Keys
Z44A730465-001
Z44A730465-016
Z44A730465-002
Motor Feedback Connector Kit
90 Deg
ZA06B-6114-K204#E
ZA06B-6114-K204#E
ZA06B-6114-K204#E
Straight ZA06B-6114-K204#S ZA06B-6114-K204#SZA06B-6114-K204#S
Motor Power/Brake Connector Kit
90 Deg
ZA06B-6114-K220#E
ZA06B-6114-K220#E
n/a
StraightZA06B-6114-K220#SZA06B-6114-K220#S
n/a
Motor Power Connector Kit
90 Deg
n/a n/a
Z44A730464-G18
Straight
n/a n/a
Z44A730464-G17
Motor Brake Connector Kit
90 Deg
n/a
n/a
ZA06B-6114-K213#E
Straight n/a
n/aZA06B-6114-K213#S
Accessories
α2/6000HVis
α4/5000HVi
α8/6000HVis
DC Link Bus Bars
Z44A718031-G05
Z44A718031-G05
Z44A718031-G05
Spare Amplifier Control Power Fuse
ZA06B-6073-K250
ZA06B-6073-K250
ZA06B-6073-K250
IC800ABK001
IC800ABK001
Encoder Battery Back-up (Multi-Axis Panel Mounted Kit) (Note 2)IC800ABK001
IC800ABK002 IC800ABK002IC800ABK002
Encoder Battery Back-up (Single-Axis Built-in) (Note 2)
1) Separate user installed cooling fan is only required for the βSVM1-40HVi amplifier. This fan kit is included in the IC800BIHV040 amplifier kit but must be separately ordered when the ZA06B-6131-H003
amplifier is ordered.
2) C
ontents of encoder battery kits is shown on page 78
5.46
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Amplifiers
αHVi Series Amplifier and Motor
Ordering Information
Motor Model
α12/4000HVis
α22/3000HVi
α22/4000HVis
Motor Part Number
ZA06B-0239-B200 ZA06B-0249-B200
ZA06B-0266-B200
Motor/Brake Part Number­­­­
ZA06B-0239-B500 ZA06B-0249-B500
ZA06B-0266-B500
Beta Amplifier Model
βSVM1-40HVi
βSVM1-40HVin/a
Beta Amplifier Part Number
ZA06B-6131-H003
ZA06B-6131-H003
n/a
Beta Amplifier Fan Kit (Note1)
ZA06B-6134-K002ZA06B-6134-K002
n/a
Beta Amplifier Kit
IC800BIHV040
IC800BIHV040
n/a
Alpha Amplifier Model
αSVM1-40HVi
αSVM1-40HVi
αSVM1-80HVi
Alpha Amplifier Part Number
ZA06B-6127-H104 ZA06B-6127-H104
ZA06B-6127-H105
Alpha Amplifier Kit
IC800AIHV040
IC800AIHV040
IC800AIHV080
Cables
α12/4000HVis
α22/3000HVi
Power Cable
Power Cable (Shielded)
Feedback Cable (Right Angle)
Feedback Cable (Straight)
Brake Power Cable
PSM Interface Cable (External Battery)
PSM Interface Cable (Built-in or No Battery)
Fiber Optic Command Cable
Fiber Optic Cable (Sheathed)
7 M
CP3I-0WPB-0070-AZ 14 M
CP3I-0WPB-0140-AZ
7 M
CP3I-0WEB-0070-AZ
14 M
CP3I-0WEB-0140-AZ
7 M
CFDA-7WPB-0070-AZ 14 M
CFDA-7WPB-0140-AZ 7 M
CFDA-0WPB-0070-AZ 14 M
CFDA-0WPB-0140-AZ 7 M
CB4N-0WPM-0070-AZ
14 M
CB4N-0WPM-0140-AZ 200 mm
Z44C746453-001 200 mm
Z44C746453-002
15 CM
30 CM
1 M
2 M
3 M
1 M
3 M
5 M
10 M
20 M
30 M
50 M
100 M
Connector Kits
α22/4000HVis
CP4I-0WPB-0070-AZ
CP4I-0WPB-0140-AZ
CP4I-0WEB-0070-AZ
CP4I-0WEB-0140-AZ
CFDA-7WPB-0070-AZ
CFDA-7WPB-0140-AZ
CFDA-0WPB-0070-AZ
CFDA-0WPB-0140-AZ
CB4N-0WPM-0070-AZ
CB4N-0WPM-0140-AZ
Z44C746453-001
Z44C746453-002
ZA66L-6001-0023#L150R0
ZA66L-6001-0023#L300R0
ZA66L-6001-0023#L1R003
ZA66L-6001-0023#L2R003
ZA66L-6001-0023#L3R003
ZA66L-6001-0026#L1R003
ZA66L-6001-0026#L3R003
ZA66L-6001-0026#L5R003
ZA66L-6001-0026#L10R03
ZA66L-6001-0026#L20R03
ZA66L-6001-0026#L30R03
ZA66L-6001-0026#L50R03
ZA66L-6001-0026#L100R3
CP4I-0WPB-0070-AZ
CP4I-0WPB-0140-AZ
CP4I-0WEB-0070-AZ
CP4I-0WEB-0140-AZ
CFDA-7WPB-0070-AZ
CFDA-7WPB-0140-AZ
CFDA-0WPB-0070-AZ
CFDA-0WPB-0140-AZ
CB4N-0WPM-0070-AZ
CB4N-0WPM-0140-AZ
Z44C746453-001
Z44C746453-002
α22/3000HVi
α22/4000HVis
α12/4000HVis
Encoder Feedback Connector (JF1)
ZA06B-6073-K214
ZA06B-6073-K214
ZA06B-6073-K214
CXA2A/B Jumper Connector (2 Req)
ZA06B-6110-K210
ZA06B-6110-K210
ZA06B-6110-K210
CZ2 Motor Power Output Connector
ZA06B-6110-K203#ZZM
ZA06B-6110-K203#ZZM
ZA06B-6110-K203#ZZM
Motor Half Keys
Z44A730465-015
Z44A730465-003
Z44A730465-003
Motor Feedback Connector Kit
90 Deg
ZA06B-6114-K204#E
ZA06B-6114-K204#E
ZA06B-6114-K204#E
Straight ZA06B-6114-K204#S ZA06B-6114-K204#SZA06B-6114-K204#S
Motor Power Connector Kit
90 Deg
Z44A730464-G18 Z44A730464-G20
Z44A730464-G20
Straight
Z44A730464-G17 Z44A730464-G19
Z44A730464-G19
Motor Brake Connector Kit
90 Deg
ZA06B-6114-K213#E
ZA06B-6114-K213#E
ZA06B-6114-K213#E
Straight ZA06B-6114-K213#S ZA06B-6114-K213#SZA06B-6114-K213#S
Accessories
α12/4000HVis
DC Link Bus Bars
Z44A718031-G05
Spare Amplifier Control Power Fuse
ZA06B-6073-K250
Encoder Battery Back-up (Multi-Axis Panel Mounted Kit) (Note 2)IC800ABK001
Encoder Battery Back-up (Single-Axis Built-in) (Note 2)
IC800ABK002
α22/3000HVi
α22/4000HVis
Z44A718031-G05
Z44A718031-G05
ZA06B-6073-K250
ZA06B-6073-K250
IC800ABK001
IC800ABK001
IC800ABK002
IC800ABK002
1) Separate user installed cooling fan is only required for the βSVM1-40HVi amplifier. This fan kit is included in the IC800BIHV040 amplifier kit but must be separately ordered when the ZA06B-6131-H003
amplifier is ordered.
2) C
ontents of encoder battery kits is shown on page 78
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.47
Servo Amplifiers
Motion Control Systems
αHVi Series Amplifier and Motor
Ordering Information (continued)
Motor Model
α30/4000HVis
α40/4000HVis
Motor Part Number
Motor/Brake Part Number
Alpha Amplifier Model
Alpha Amplifier Part Number
Alpha Amplifier Kit
Dynamic Braking Module
ZA06B-0269-B200
ZA06B-0269-B500
αSVM1-80HVi
ZA06B-6127-H105
IC800AIHV080
n/a
ZA06B-0273-B200
ZA06B-0273-B500
αSVM1-80HVi
ZA06B-6127-H105
IC800AIHV080
n/a
Cables
α30/4000HVis
Power Cable
Power Cable (Shielded)
Feedback Cable (Right Angle)
Feedback Cable (Straight)
Brake Power Cable
Fan Cable
PSM Interface Cable (External Battery)
PSM Interface Cable (Built-in or No Battery)
Fiber Optic Command Cable
Fiber Optic Cable (Sheathed)
α40/4000HVis
7 M
CP4I-0WPB-0070-AZ
CP4I-0WPB-0070-AZ
14 M
CP4I-0WPB-0140-AZ
CP4I-0WPB-0140-AZ
7 M
CP4I-0WEB-0070-AZ
CP4I-0WEB-0070-AZ
14 M
CP4I-0WEB-0140-AZ
CP4I-0WEB-0140-AZ
7 M
CFDA-7WPB-0070-AZ
CFDA-7WPB-0070-AZ
14 M
CFDA-7WPB-0140-AZ
CFDA-7WPB-0140-AZ
7 M
CFDA-0WPB-0070-AZ
CFDA-0WPB-0070-AZ
14 M
CFDA-0WPB-0140-AZ
CFDA-0WPB-0140-AZ
7 M
CB4N-0WPM-0070-AZ
CB4N-0WPM-0070-AZ
14 M
CB4N-0WPM-0140-AZ
CB4N-0WPM-0140-AZ
7 M
n/a
n/a
14 M
n/a
n/a
200 mm
Z44C746453-001
Z44C746453-001
200 mm
Z44C746453-002
Z44C746453-002
15 CM ZA66L-6001-0023#L150R0
30 CM ZA66L-6001-0023#L300R0
1 M ZA66L-6001-0023#L1R003
2 M ZA66L-6001-0023#L2R003
3 M ZA66L-6001-0023#L3R003
1 M ZA66L-6001-0026#L1R003
3 M ZA66L-6001-0026#L3R003
5 M ZA66L-6001-0026#L5R003
10 M ZA66L-6001-0026#L10R03
20 M ZA66L-6001-0026#L20R03
30 M ZA66L-6001-0026#L30R03
50 M ZA66L-6001-0026#L50R03
100 M ZA66L-6001-0026#L100R3
Connector Kits
Encoder Feedback Connector (JF1)
CXA2A/B Jumper Connector (2 Req)
CZ2 Motor Power Output Connector
CX8/CX9 DB Module Interface Connector Kit
CX1A/B 180HVi Amplifier Control Power Motor Half Keys
Motor Feedback Connector Kit
90 Deg
Straight
Motor Power Connector Kit
90 Deg
Straight
Motor Brake Connector Kit
90 Deg
Straight
Motor Fan Connector Kit
90 Deg
Straight
α30/4000HVis
ZA06B-6073-K214
ZA06B-6073-K214
ZA06B-6110-K210
ZA06B-6110-K210
ZA06B-6110-K203#ZZM
ZA06B-6110-K203#ZZM
n/a
n/a
n/a
n/a
Z44A730465-003
Z44A730465-003
ZA06B-6114-K204#E
ZA06B-6114-K204#E
ZA06B-6114-K204#SZA06B-6114-K204#S
Z44A730464-G20
Z44A730464-G20
Z44A730464-G19Z44A730464-G19
ZA06B-6114-K213#E
ZA06B-6114-K213#E
ZA06B-6114-K213#SZA06B-6114-K213#S
n/a
n/a
n/an/a
Accessories α30/4000HVis
DC Link Bus Bars
Spare Amplifier Control Power Fuse
Encoder Battery Back-up (Panel Mounted Kit) (Note 1)
Encoder Battery Back-up (Built-in) (Note 1)
α40/4000HVis
α40/4000HVis
Z44A718031-G05
Z44A718031-G05
ZA06B-6073-K250
ZA06B-6073-K250
IC800ABK001IC800ABK001
IC800ABK002IC800ABK002
1) Contents of encoder battery kits is shown on page 78
5.48
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Amplifiers
αHVi Servo System Connection
Ordering Information (continued)
Motor Model
α50/3000HVis w/ Fan
α100/2500HVis w/ Fan
Motor/Brake Part Number
Motor Part Number
Beta Amplifier Model
Beta Amplifier Kit Number
Beta Amplifier Part Number
Alpha Amplifier Model
Alpha Amplifier Part Number
Alpha Amplifier Kit Number
Dynamic Braking Module (req for SVM1-180HVi)
ZA06B-0276-B210
ZA06B-0276-B510
n/a
n/a
n/a
αSVM1-180HVi
ZA06B-6124-H106
IC800AIHV180
ZA06B-6079-H401
ZA06B-0286-B310
ZA06B-0286-B010
n/a
n/a
n/a
aSVM1-180HVi
ZA06B-6124-H106
IC800AIHV180
ZA06B-6079-H401
Cables
α50/3000HVis w/ Fan
Motor Power Cable
Motor Power Cable (Shielded)
Motor Feedback Cable (Right Angle)
Motor Feedback Cable (Straight)
Motor Brake Power Cable
Motor Fan Cable
PSM Interface Cable (External Battery)
PSM Interface Cable (Built-in or No Battery)
Fiber Optic Command Cable
Fiber Optic Command Cable (Sheathed)
α100/2500HVis w/ Fan
7 M
CP9I-0MPB-0070-AZ
Supplied by customer
14 M
CP9I-0MPB-0140-AZ
7 M
CP9I-0MEB-0070-AZ
Supplied by customer
14 M
CP9I-0MEB-0140-AZ
7 M
CFDA-7WPB-0070-AZ
CFDA-7WPB-0070-AZ
14 M
CFDA-7WPB-0140-AZ
CFDA-7WPB-0140-AZ
7 M
CFDA-0WPB-0070-AZ
CFDA-0WPB-0070-AZ
14 M
CFDA-0WPB-0140-AZ
CFDA-0WPB-0140-AZ
7 M
CB4N-0WPM-0070-AZ
CB4N-0WPM-0070-AZ
14 M
CB4N-0WPM-0140-AZ
CB4N-0WPM-0140-AZ
7 M
CB5N-0WPM-0070-AZ
CB5N-0WPM-0070-AZ
14 M
CB5N-0WPM-0140-AZ
CB5N-0WPM-0140-AZ
200 mm
Z44C746453-001
Z44AC746453-001
200 mm
Z44C746453-002
Z44AC746453-002
15 CM ZA66L-6001-0023#L150R0
30 CM ZA66L-6001-0023#L300R0
1 M ZA66L-6001-0023#L1R003
2 M ZA66L-6001-0023#L2R003
3 M ZA66L-6001-0023#L3R003
1 M ZA66L-6001-0026#L1R003
3 M ZA66L-6001-0026#L3R003
5 M ZA66L-6001-0026#L5R003
10 M ZA66L-6001-0026#L10R03
20 M ZA66L-6001-0026#L20R03
30 M ZA66L-6001-0026#L30R03
50 M ZA66L-6001-0026#L50R03
100 M ZA66L-6001-0026#L100R3
Connector Kits α50/3000HVis w/ Fan
α100/2500HVis w/ Fan
Amplifier Encoder Feedback Connector (JF1)
ZA06B-6073-K214
ZA06B-6073-K214
CXA2A/B Jumper Connector (2 Req)
ZA06B-6110-K210
ZA06B-6110-K210
CZ2 Motor Power Output Connector
ZA06B-6110-K203#ZZM
n/a
CX8/CX9 DB Module Interface Connector Kit
ZA06B-6073-K216
ZA06B-6073-K216
CX1A/B 180HVi Amplifier Control Power ZA02B-0120-K321
ZA02B-0120-K321
Motor Half Keys
n/a
n/a
Motor Feedback Connector Kit
90 Deg
ZA06B-6114-K204#E
ZA06B-6114-K204#E
StraightZA06B-6114-K204#S
ZA06B-6114-K204#S
Motor Power Connector Kit
90 Deg
Z44A730464-G20
n/a
StraightZ44A730464-G19
n/a
Motor Brake Connector Kit
90 Deg
ZA06B-6114-K213#E
ZA06B-6114-K213#E
StraightZA06B-6114-K213#S
ZA06B-6114-K213#S
Motor Fan Connector Kit
90 Deg
ZA06B-6114-K214#E
ZA06B-6114-K214#E
StraightZA06B-6114-K214#S
ZA06B-6114-K214#S
Accessories
α50/3000HVis w/ Fan
α100/2500HVis w/ Fan
DC Link Bus Bars
Z44A718031-G12
Z44A718031-G12
Spare Amplifier Control Power Fuse
ZA06B-6073-K250
ZA06B-6073-K250
Encoder Battery Back-up (Panel Mounted Kit)
IC800ABK001
IC800ABK001
Encoder Battery Back-up (Built-in)
IC800ABK002
IC800ABK002
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.49
Servo Amplifiers
Motion Control Systems
PSM-HVi Power Supply
Ordering Information
The αHVi series amplifiers use a separately mounted shared
power supply. A power supply module (PSM) can service multiple
amplifiers in a multi-axis system. A maximum of six amplifiers
Model Number
may be connected to one power supply module; however, the
number of amplifier may be limited by the power supply ratings.
PSM-11HViPSM-18HViPSM-30HViPSM-45HVi
Power Supply Kit IC800PSHV011IC800PSHV018IC800PSHV030IC800PSHV045
Power Supply Only
ZA06B-6150-H011ZA06B-6150-H018ZA06B-6150-H030ZA06B-6150-H045
Continuous Output Rating
11183045
Peak Output Rating*
34
58
87
124
DC Link Bus Bars
Z44A718031-G03
Z44A718031-G03
Z44A718031-G12
Z44A718031-G12
Connectors and Cables
Connector Kit (Includes CX4
ZA06B-6071-K203
ZA06B-6071-K203
ZA06B-6071-K203
ZA06B-6071-K203
Estop, CX3 MCC and CX1A
Control Power Connectors)
MCC Coil Control Output 10 Ft
Z44C742171-001
Z44C742171-001
Z44C742171-001
Z44C742171-001
Flying Lead Cable
200V Control Power Input 25 Ft
Z44C742172-001
Z44C742172-001
Z44C742172-001
Z44C742172-001
Flying Lead Cable
Estop Input Flying Lead Cable
10 Ft
Z44C742176-001Z44C742176-001Z44C742176-001Z44C742176-001
Accessories
Spare Control Power Fuse
ZA06B-6077-K250
ZA06B-6077-K250
ZA06B-6077-K250
ZA06B-6077-K250
AC Line Filter ZA81L-0001-0163ZA81L-0001-0163ZA81L-0001-0164ZA81L-0001-0164
Noise Filter for PSM (required for CE)
ZA06B-6077-K155
ZA06B-6077-K156
ZA06B-6077-K156
ZA06B-6077-K157
*Peak rating is for 0.3 seconds
Selecting a Power Supply
Step 1 - Determine the total number and type of αHVi or αHVis series motors that will be required from the list below. If more than six
axes are required divide them into groups of no more than six motors.
Motor Model
Continuous Output
α22/3000HVi
4.0 kW α22/4000HVis
4.5 kW α30/4000HVis
5.5 kW
α40/4000HVis
5.5 kW
α50/3000HVis with fan
14 kW
α100/2500HVis with fan
11 kW
Acceleration Output
9.6 kW
20 kW
22 kW
24 kW
39 kW
38 kW
Step 2 - Total the continuous output for all motors in a group and multiply by 0.6.
Step 3 - Total the acceleration output for all motors in each group.
Step 4 - Compare the continuous and acceleration output totals for each group to the continuous rating and peak rating for the
power supply modules and select a PSM module to meet the following conditions:
a) Motor Continuous Output Total * 0.6 must be less than the PSM Continuous Output Rating
b) Motor Acceleration Output Total must be less than the PSM Peak Output Rating
Example:
An application requires the following motors:
Qty 2 α22/4000HVis
Qty 2 α30/4000HVis
Qty 1 α50/3000HVis with fan
Since the total number of motors is less than six, assume that one PSM will be used. Therefore, the total ratings for the system are:
Total the continuous output for all motors multiplied by 0.6 = 28 kW * 0.6 = 16.8 kW
Total the acceleration output for all motors = 123 kW
Select the PSM-45HVi module with a continuous output rating of 45 kW and peak output rating of 124 kW.
5.50
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Motors
αi and βi Series
Servo Motors
Servo Motor Performance for
Demanding Applications
The FANUC Servo motors are a rugged family of brushless servo
motors covering a broad torque and speed range. These motors
utilize high energy rare earth magnets for superior cost/performance ratio. Low inertia design ­provides high acceleration rates
for improved machine cycle rates. The αi and βi Series motors
use high resolution serial encoder feedback and are matched
with amplifiers and PACMotion PMM335 Motion Controllers.
Feature Comparison
Feature
αHVis Series
βis Series
βHVis Series
Cont. Stall Torque Range (In-lb (Nm))
17.7-664 (2-75)
3.5-177 (0.4-20)
17.7-177 (2-20)
Cont. Speed Range (RPM)
2000-6000
2000-6000
2000-4000
Max. Speed Range (RPM)
3000-6000
2000-6000
2000-4000
Compatible Amplifiers
αHVi Series
βi Series
βHVi Series
Compatible Controllers
PMM335/DSM324iPMM335/DSM324iPMM335/DSM324i
Mounting
MetricMetricMetric
Shaft Configuration
Straight/KeywayStraight/KeywayStraight/Keyway
Brushless Construction
YesYesYes
Optional Brake
24VDC
24 VDC
24 VDC
Feedback Type
Serial Encoder
Serial Encoder
Serial Encoder
Feedback Resolution (Counts/rev)
1 M
64 K/128 K
128 K
Absolute Feedback
Yes*Yes*Yes*
Amplifier Line Voltage
400-480 VAC 3 φ
220-240 VAC 1 φ
400-480 VAC 3 φ
200-240 VAC 3 φ
Shaft Seal
StandardStandardStandard
Protection Rating
IP65 Standard
IP65 Standard
IP65 Standard
IP67 Optional
IP67 Optional
IP67 Optional
Inertia
Low MediumMedium
*Absolute feedback requires optional encoder battery backup for αHVi Series, βi Series, or βHVi Series amplifiers.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.51
Servo Motors
Motion Control Systems
αHVi and αHVis Series Servo Motors
Motor Part Numbers
ZA06B -0 249 -B
Motor Model
αHVi Series
2
219- α2/6000HVis
216- α4/5000HVis
233- α8/6000HVis
239- α12/4000HVis
249- α22/3000HVi
266- α22/4000HVis
269- α30/4000HVis
273- α40/4000HVis
276- α50/3000HVis
286- α100/2500HVis
0 0
0 - Straight Shaft with Keyway (Except α50/3000HVis
which does not have a Shaft Key)
0 - No Fan Cooling
1 - Fan Cooling (α50/3000HVis and α100/2500HVis only)
0 - No Brake (α100/2500HVis model only)
2 - No Brake (all other models)
3 - 24 VDC Brake (α100/2500HVis model only)
5 - 24 VDC Brake (all other models)
βis and βHVis Series Servo Motors
Motor Part Numbers
ZA06B -0 114 -B
Motor Model
βi Series
5.52
114- β0.4/5000is
115- β0.5/5000is
116- β1/5000is
061- β2/4000is
062- β2/4000HVis
063 - β4/4000is
064- β4/4000HVis
075- β8/3000is
076- β8/3000HVis
078- β12/3000is
079- β12/3000HVis
085- β22/2000is
086- β22/2000HVis
GE Intelligent Platforms Control Systems Solutions
2
0 3 #0100
Protection
Blank- IP65 (standard)
#0100- IP67 (optional)
Shaft
3- Straight Shaft with Keyway
Fan Cooling
0- No Fan Cooling
Brake
2- No Brake
5- 24 VDC Brake
www.ge-ip.com
Motion Control Systems
Servo Motors
αHVi and αHVis Series Servo Motors
Specifications
Motor Model
Unit
α2/6000HVis
α4/5000HVis
α8/6000HVis
α12/4000HVis
α22/3000HVi
Cont Stall Torque*
Nm
2
4
8
12
22
in-lb17.7 35.4 70.8
106
195
Peak Torque*
Nm
6
8.8
22
46
64
in-lb53.1 77.9 194.7
407
566
2.915.15 11.7 22.8 120
Rotor Inertia
kgm2 x 10-4
45.58
103.54
201.7
1062
in-lb-s2 x 10-425.75
Rated Speed
RPM
6000
4000
6000
3000
3000
No Load Speed
RPM
6000
5000
6000
4000
4000
Encoder Resolution
Counts/Rev
1,000,000
1,000,000
1,000,000
1,000,000
1,000,000
Flange Size
mm
90
90
130
130
174
Mechanical Data
Weight kg3 4.3
lb6.6 9.46
Axial Load Rating
kg
8
8
lb17.6 17.6
Radial Load Rating
kg
25
25
lb55 55
Mechanical Time Constant msec
5
3
Thermal Time Constant
min
15
20
Static Friction
Nm
0.1
0.2
8 11.9 29
17.6 26.2 63.8
20
20
60
44
44
132
70
70
200
154 154 440
2
2
4
20
25
60
0.3
0.3
1.2
Electrical Data
Torque Constant*
Nm/A
0.99
1.32
0.89
in-lb/A8.76 11.68 7.87
Resistance*ohms 5.6
2.8
0.5
Back EMF Constant*
V(rms)/krpm
35
46
31
Rated Motor Power
kW
1
1
2.2
HP1.3 1.3 3
Cont. Stall Current
A (rms)
2
3
9
Max Current
A (peak)
40
40
40
Insulation
Class F
Class F
Class F
1.8
2.41
15.9
21.33
0.84
0.66
63
84
2.5
4
3.4
5.4
6.7
9.1
40
40
Class F
Class F
Amplifier Model
α Amp Model Number
β Amp Model Number
αSVM1-10HVi αSVM1-10HVi
αSVM1-40HVi
βSVM1-10HVi βSVM1-10HVi βSVM1-40HVi
αSVM1-40HVi
βSVM1-40HVi
αSVM1-40HVi
βSVM1-40HVi
Brake Data
Holding Torque
Nm
3
3
in-lb26.6 26.6
0.2
Inertia Adder
kgm2 x 10-40.2
1.77
in-lb-s2 x 10-41.77
Weight Adder
kg
1
1
lb2.2 2.2
Current A0.9 0.9
Voltage VDC24 24
Engage Time
msec
20
20
Release Time
msec
60
60
8
71
0.7
6.18
2.2
4.9
1.1
24
30
160
8
71
0.7
6.18
2.2
4.9
1.1
24
30
160
35
310
6
53
6
13.2
1.2
24
30
160
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Cooling Fan Data
AC Input 60 Hz
AC Input 50 Hz
Rated Current 60 Hz
Rated Current 50 Hz
VAC
VAC
A (rms)
A (rms)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Environmental Specifications
Humidity
80% non-condensing
Ambient Temperature
0 to 40ºC
Vibration
less than 5G (operating)
Altitude
3300 feet (1000 m)
*Data shown are nominal values at 20ºC
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.53
Servo Motors
Motion Control Systems
αHVi and αHVis Series Servo Motors
Specifications
Motor Model
Unit
α22/4000HVis
α30/4000HVis
α40/4000HVis
α50/3000HVis
with fan
α100/2500HVis
with fan
Cont Stall Torque*
Nm
22
30
40
75
140
in-lb 195 266 354 6641240
Peak Torque*
Nm
70
100
115
215
274
in-lb 620 885 101819032425
Rotor Inertia
kgm2 x 10-452.7 75.9 99 145 252
in-lb-s2 x 10-4466 672 876 1283 2230
Rated Speed
RPM 30003000300030002000
No Load Speed
RPM
4000
4000
4000
3000
2500
Encoder Resolution
Counts/Rev 1,000,0001,000,0001,000,0001,000,0001,000,000
Flange Size
mm 174174174174265
Mechanical Data
Weight kg 17 23 28 42100
lb 37.450.661.6 92.4 220
Axial Load Rating
kg
60
60
60
60
250
lb 132132132132550
Radial Load Rating
kg
200
200
200
200
900
lb 440 440 440 4401980
Mechanical Time Constant msec
2
2
1
1
.06
Thermal Time Constant
min
30
35
40
30
40
Static Friction
Nm 0.80.81.21.82.2
Electrical Data
Torque Constant*
Nm/A1.421.9 2.2 1.92.53
in-lb/A 12.5716.8219.4716.8222.39
Resistance*
ohms 0.250.250.23 0.10.052
Back EMF Constant*
V(rms)/krpm
50
66
77
66
88
Rated Motor Power
kW
4.5
5.5
5.5
14
22
HP 6.0 7.4 7.418.830
Cont. Stall Current
A (rms)
15.5
15.9
18.1
39.6
55
Max Current
A (peak)
80
80
80
180
180
Insulation
Class F
Class F
Class F
Class F
Class F
Amplifier Model
α Amp Model Number
β Amp Model Number
αSVM1-80HVi
n/a
αSVM1-80HVi
n/a
αSVM1-80HVi
n/a
αSVM1-180HVi
n/a
αSVM1-180HVi
n/a
Brake Data
Holding Torque
Nm
35
35
35
35
150
in-lb 310 310 310 3101327
Inertia Adder
kgm2 x 10-46 6 6 6 10
53 53
53 88.5
in-lb-s2 x 10-453
Weight Adder
kg
6
6
6
6
15
lb 13.213.213.2 13.2 33
Current A 1.21.21.21.22.5
Voltage VDC 2424242424
Engage Time
msec3030303060
Release Time
msec 160160160160360
Cooling Fan Data
AC Input 60 Hz
AC Input 50 Hz
Rated Current 60 Hz
Rated Current 50 Hz
VAC
VAC
A (rms)
A (rms)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
170-220 1-phase
170-242 1-phase
0.27
0.32
391 to 528 3-phase
323 to 440 3-phase
0.2
0.2
Environmental Specifications
Humidity
Ambient Temperature
Vibration
Altitude
80% non-condensing
0 to 40º C
less than 5G (operating)
3300 feet (1000 m)
*Data shown are nominal values at 20º C
5.54
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Motors
αHVi and αHVis Series Servo Motors
Speed Torque Curves
The curves illustrate the relationship
between motor speed and output torque.
The motor can operate continuously
at any combination of speed and
torque within the prescribed continuous
operating zone. The limit of the continuous operating zone is determined with
the motor’s ambient temperature at 20°C
and its drive current as a pure sine wave.
Actual operation is limited by the current
α2/6000HVis
9
4
3
7
20
Intermittent Operation
Torq ue ( N m )
8
Intermittent Operation
5
Torq ue ( N m )
6
5
4
Intermittent Operation
15
10
3
2
2
Continuous Operation
1
1
0
1000
2000
3000
4000
5000
0
6000
1000
2000
Speed (RPM)
3000
4000
α12/4000HVis
60
40
30
3000
0
4000
2000
40
30
0
3000
Continuous Operation
1000
2000
3000
4000
Speed (RPM)
α40/4000HVis
140
250
α50/3000HVis w/Fan
120
100
To rq ue (Nm)
Intermittent Operation
80
60
40
0
Intermittent Operation
Speed (RPM)
α30/4000HVis
20
6000
50
10
1000
Speed (RPM)
120
5000
20
Continuous Operation
10
2000
4000
70
Intermittent Operation
50
Torq ue (Nm)
Torqu e (Nm)
Continuous Operation
3000
α22/4000HVis
20
1000
2000
80
60
Intermittent Operation
20
0
1000
Speed (RPM)
α22/3000HVi
70
30
10
0
5000
Continuous Operation
Speed (RPM)
50
40
5
Continuous Operation
Continuous Operation
1000
100
80
60
2000
3000
4000
Intermittent Operation
150
100
40
20
Speed (RPM)
200
Intermittent Operation
Torqu e (Nm)
Torq ue ( N m )
25
10
6
Torq ue (Nm)
α8/6000HVis
α4/5000HVis
7
To rq ue (Nm)
of the servo drive unit. The continuous
operating zone must be derated for
­ambient temperature above 20°C.
0
50
Continuous Operation
1000
2000
Speed (RPM)
3000
4000
0
Continuous Operation
2000
1000
3000
Speed (RPM)
α100/2500HVis with Fan
300
Torque (Nm )
250
200
Intermittent Operation
150
100
50
0
Continuous Operation
1000
2000
Speed (RPM)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.55
Servo Motors
Motion Control Systems
αHVi Series Servo Motors
Dimensions
α2/6000HVis
32
4 - ø 6.6 ON ø 100 D.B.C
ø 43
ø 80 +0
-0.03
12
+0.5
-0.5
22
75
10
40
20
3
66.2
56.7
ø1
7
8.7
4
D
21.4
30.6
C
Power Connections
B
90
A
Motor
23
18
8
3
4
W
G
5
6
12
1
2
3
4
5
6
U
V
W
G
B
B
+0.012
ø 14 +0.001
16
11
+0
11.2
10 -0.009
+0
3 -0.025
2
V
Power/Brake Connections
+0
-0.030
5
B2/4_iseries_MOTOR.eps
1
U
M5 Depth 12
Shaft detail
Dimensions shown mm
Dimension
α2/6000HVis
A130
A with brake
159
B119
B with brake
148
C75
C with brake
75
D59
D with brake
59
B2/4_4/4iseries_SHAFT.eps
Notes
1. Shaft diameter runout = 0.02 mm max
2. Flange surface runout = 0.06 mm max
3. Maximum radial load for output shaft is 25 kgf (55 lb)
5.56
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Motors
αHVi Series Servo Motors
Dimensions
α4/5000HVis
30
4 - ø 6.6 ON ø 100 D.B.C
ø 43
ø 80 +0
-0.03
22
75
14
40
20
3
66.2
56.7
ø1
7
8.7
4
D
21.4
30.6
C
Power Connections
B
90
A
Motor
23
5
2
3
4
V
W
G
5
6
Power/Brake Connections
+0
-0.030
12
B4/4_iseries_MOTOR.eps
1
2
3
4
5
6
U
V
W
G
B
B
11
16
+0.012
ø 14 +0.001
8
1
U
M5 Depth 12
Shaft detail
Dimension
Dimensions shown mm
α4/5000HVis
A166
A with brake
195
B155
B with brake
184
C111
B2/4_4/4iseries_SHAFT.eps
C with brake
111
D95
D with brake
95
Notes
1. Shaft diameter runout = 0.02 mm max
2. Flange surface runout = 0.06 mm max
3. Maximum radial load for output shaft is 25 kgf (55 lb)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.57
Servo Motors
Motion Control Systems
αHVi Series Servo Motors
Dimensions
α8/6000HVis and α12/4000HVis
55
4- ø 9 ON ø 145 D.B.C.
45º
4
31
6
22
52
75
130
22
1
20
(8.7)
10
35
(8.7)
25
40
3
72
65
ø 74
+0
ø 110 -0.035
ø1
39.5
+0
5 -0.030
47
B
Motor
2
A
A1
+0
6 -0.03
2 - M4 DEPTH 10
+0
3 -0.29
8 -0.036
+0
2.5 -0.13
+0
M8 DEPTH 16
B8/3_12/3iseries_MOTOR.eps
10
+0
+0
ø 19 -0.013
ø 24 -0.021
Shaft detail
β8/3000is
β8/3000HVis
Dimension
α8/6000HVis
A
A with brake
B
B with brake
C
C with brake
β12/3000is
β12/3000HVis
α12/4000HVis
166222
191
247
108164
133
189
4747
47
47
ConnectorDescription
1
Brake (optional)
2Power
3
Encoder
B8/3_12/3iseries_SHAFT.eps
Notes
1. Shaft diameter runout = 0.02 mm max
2. Flange surface runout = 0.05 mm max
3. Maximum radial load for output shaft is 70 kgf (154 lb)
5.58
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Motors
αHVi Series Servo Motors
Dimensions
α22/3000HVi
ø
45º
B
23
3.2
0
31
20
25
127
102.7
48.7
+0
ø114.3 - 0.025
22
44
3
12
38
174
1
2
C
B
A
13.5 DIA HOLES
ON 200 D.B.C.
Motor
79
3.2
+0.01
+0
3 - 0.3
70
ø35 -0
+0
ø114.3 -0.025
10 +0
- 0.0 36
2-M6
DEPTH10
20
Dimensions shown mm
Shaft detail
Dimension
α22/3000HVi
A276
A with brake
317
B265
B with brake
306
C215
C with brake
256
ConnectorDescription
1
Brake (optional)
2Power
3
Encoder
Notes
1. Shaft diameter runout = 0.03 mm max
2. Flange surface runout = 0.06 mm max
3. Maximum radial load for output shaft is 200 kgf (440 lb)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.59
Servo Motors
Motion Control Systems
αHVi Series Servo Motors
Dimensions
α22/4000HVis, α30/4000HVis, α40/4000HVis
ø
45º
B
23
3.2
0
31
20
25
127
102.7
48.7
+0
ø114.3 - 0.025
22
44
3
12
38
1
2
C
B
A
13.5 DIA HOLES
174
ON 200 D.B.C.
Motor
79
3.2
+0.01
+0
3 - 0.3
70
ø35 -0
+0
ø114.3 -0.025
10 +0
- 0.0 36
2-M6
DEPTH10
20
Dimensions shown mm
Shaft detail
Dimension
α22/4000HVis
A
A with brake
B
B with brake
C
C with brake
α30/4000HVis
α40/4000HVis
202239
243
280
191228
232
269
141178
182
219
276
317
265
306
215
256
ConnectorDescription
1
Brake (optional)
2Power
3
Encoder
Notes
1. Shaft diameter runout = 0.03 mm max
2. Flange surface runout = 0.06 mm max
3. Maximum radial load for output shaft is 200 kgf (440 lb)
5.60
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Motors
αHVi Series Servo Motors
Dimensions
α50/3000HVis with Fan
ø
45º
288
60
23
0
IN
127
102.7
25
48.7
+0
ø114.3 -0.025
AIR
12
38
174
50
B
A
13.5 DIA HOLES
ON 200 D.B.C.
Motor
330
79
3.2
52
62
+0.01
52
62
ø35 -0
+0
ø114.3 -0.025
4
1
2
3
20
Shaft detail
TAPS for eyebolts: m8 depth 15 +1
-0
Dimensions shown mm
Dimension
Dimensions shown mm
α50/3000HVis with Fan
A416
A with brake
457
B289
B with brake
330
ConnectorDescription
1
Brake (optional)
2Power
3
Encoder
4
Fan
Notes
1. Shaft diameter runout = 0.03 mm max
2. Flange surface runout = 0.06 mm max
3. Maximum radial load for output shaft is 200 kgf (440 lb)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.61
Servo Motors
Motion Control Systems
α100/2500HVis Series Servo Motors
Dimensions
3.2 -0.2
0
0
10 -0.036
M36 P=3
Ø4
20 2
5
Ø55
α100/2500HVis
1 / 1 0 TA P E R
S H A F T D E TA I L
18 DIA 4 HOLES
BRAKE
C O NNECTOR
ON 300 D.B.C.
TERMINAL BOX
B
132
168
90
82
(9)
178
34
8
130
Ø90
+0
Ø250h7 -0.046
265
Ø
38
C
M8
X M8
2
6
Dimension
168
C O NNECTOR
F A N C O NNECTOR
2 2 ±0.06 G A U G E
41
PULSECODER
226
23
X
25
60 63
282
Y
A
α100/2500HVis
A452
A with brake
584
B129
B with brake
225
C220
C with brake
316
Notes
1. Shaft diameter runout = 0.03 mm max
2. Flange surface runout = 0.06 mm max
3. Maximum radial load for output shaft is 900 kgf (1980 lb)
5.62
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Motors
αHVi and αHVis Series Servo Motors
Connections
Serial Encoder Connections
1
2
4
5
9
7
10
All αHVi and αHVis Motors
1
3
5
7
αHVi Series Amplifier
JF1 Connector
N/C2
N/C1
RD6
RD5
+5 VDC
8, 9
0 VDC
7, 10
+6 VA (battery)
4
Frame Ground
3
Cable Shield
3
3
6
8
Description
αHVi and αHVis Motors
1
2
5
6
9, 20
12, 14
7
16
16
GE Mating Motor Connector:
Amplifier Mating Connector (JF1):
ZA06B-6114-K204#E (90 degree) ZA06B-6073-K214
ZA06B-6114-K204#S (Straight)
9
2
4
6
8
10
12
14
16
18
20
αHVi Amplifier (JF1)
Power and Brake Connections
6 5 4 3 2 1
α2/6000HVis and α4/5000HVis Motor Power/Brake
D
A
C
B
All other αHVi and αHVis Motor Power
1
2
3
All other αHVi and αHVis Brake
1
Phase U
Phase V
Phase W
Earth (case)
Brake VDC
Brake VDC
All other
αSVM1-10HVi/
αSVM1-180HVi
αHVi and αHVis40HVi/80HViAmplifier
Motor Connector
CZ2 Connector
TB2 Connector
1
2
3
4
5
6
A
B
C
D
n/a
n/a
B1
A1
B2
A2
n/a
n/a
U
V
W
PE
n/a
n/a
GE Mating Motor Connector:
Amplifier Mating Connector (CZ2):
ZA06B-6114-K220#E (90 degree) (α2HVis and α4HVis)ZA06B-6110-K203#ZZN
ZA06B-6114-K220#S (Straight) (α2HVis and α4HVis)
Z44A730464-G20 (90 degree) (αHVi and αHVis)
Z44A730464-G19 (Straight) (αHVi and αHVis)
Z44A730464-G18 (90 degree) (α12/4000HVis)
Z44A730464-G17 (Straight) (α12/4000HVis)
Description
α8HVis, α12HVis, α22HVi, α22HVis, α30HVis, α40HVis, α50HVis, α100HVis Motor Brake Connector
4
2
Description
α2HVis and α4HVis
Motor Connector
A2
B2 G
W
A1
B1 V
U
A
B
Brake VDC
Brake VDC
Earth (case)
1
2
4
GE Mating Motor Connector:
ZA06B-6114-K213#E (90 degree)
ZA06B-6114-K213#S (Straight)
24 VDC Brake power connections are not polarized.
αSVM1-10HVi, αSVM1-40HVi and αSVM1-80HVi
Amplifier (CZ2)
U
SHAFT
U
V
V
W
W
G
MOTOR COIL
GROUNDING
MOTOR BODY
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.63
Servo Motors
Motion Control Systems
αHVi and αHVis Series Servo Motor
Ordering Information
Model Number
Description
ZA06B-0216-B200
ZA06B-0216-B500
ZA06B-0219-B200
ZA06B-0219-B500
ZA06B-0233-B200
ZA06B-0233-B500
ZA06B-0239-B200 ZA06B-0239-B500 ZA06B-0249-B200
ZA06B-0249-B500
ZA06B-0266-B200
ZA06B-0266-B500
ZA06B-0269-B200
ZA06B-0269-B500
ZA06B-0273-B200
ZA06B-0273-B500
ZA06B-0276-B210
ZA06B-0276-B510
ZA06B-0286-B010
ZA06B-0286-B310
α4/5000HVis Servo Motor
α4/5000HVis Servo Motor with Brake
α2/6000HVis Servo Motor
α2/6000HVis Servo Motor with Brake
α8/6000HVis Servo Motor
α8/6000HVis Servo Motor with Brake
α12/4000HVis Servo Motor
α12/4000HVis Servo Motor with Brake
α22/3000HVi Servo Motor
α22/3000HVi Servo Motor with Brake
α22/4000HVis Servo Motor
α22/4000HVis Servo Motor with Brake
α30/4000HVis Servo Motor
α30/4000HVis Servo Motor with Brake
α40/4000HVis Servo Motor
α40/4000HVis Servo Motor with Brake
α50/3000HVis Servo Motor with Fan
α50/3000HVis Servo Motor with Fan and Brake
α100/2500HVis Servo Motor
α100/2500HVis Servo Motor with Brake
Motor Cables
See applicable amplifier section for information about the proper cables to use with
each motor.
5.64
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Motors
βi Series Servo Amplifiers
Dimensions
The βi Series amplifiers are panel mounted devices with dimensions as shown. The βi Series amplifiers must be paired with the βis
Series motors. When installing the amplifiers make sure to maintain the specified clearances above, below and between adjacent
amplifiers to allow for proper convection cooling.
βi Series Servo Amplifier Unit
βSVM1-20i
68.5 (2.70)
45 (1.77)
optional fan †
17.5 (0.69)
>
DISCHARGE TIME 2 min
CAUTION
HIGH
VOLTAGE
FANUC
CXA19B
CXA19A
/L3
DCC/DCP
V/U
/W
LED
COP10A
POWER
LINK
ALM
130 (5.12)
140 (5.51)
150 (5.91)
COP10B
L2/L1
JX5
CZ7
CX29
MCC
CX30
ESP
JF1/ENC
CX5X
CXA20
DCOH
optional encoder
battery case
optional encoder
battery case
56 (2.20)
62 (2.44)
172 (6.77)
75 (2.95)
185 (7.31)
Dimensions shown in mm (in).
βi Series Servo Amplifiers Electrical Specifications
Model
βSVM1-20i
Rated output current (rms amps)
6.8
Current limit (Peak amps)
20
AC Power
200-240 VAC (3-phase), 220-240 VAC (1-phase) 50/60 Hz ± 2 Hz
DC Control Power
24 VDC ± 10% @ 0.9 Amp per amplifier
Max. Heat loss (watts)
66
Regenerative discharge
16J
Maintenance Clearances:
40 (1.57)
10 (0.39)
Above and below amplifier
Beside and between amplifiers
* These values are standard values at 20°C with a tolerance of ±10%. The speed-torque characteristics vary depending on the parameter setting and input voltage of the digital servo amplifiers.
(The above figures show average values.) These values may be changed without prior notice.
† Separately installed cooling fan required for β4is motor when a single phase AC power source is used and always with the β8is motor.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.65
Servo Motors
Motion Control Systems
βi Series Servo Amplifiers
Dimensions
The βi Series amplifiers are panel mounted devices with dimensions as shown. The βi Series amplifiers must be paired with the βis
Series motors. When installing the amplifiers make sure to maintain the specified clearances above, below and between adjacent
amplifiers to allow for proper convection cooling.
βi Series Servo Amplifier Unit
βSVM1-40i
βSVM1-10HVi
βSVM1-40HVi
mounting flange
FANUC
FANUC LTD
Yamenashi 401-0597 JAPAN
CAUTION
CXA19B
CXA19A
COP10B
COP10A
LED
360 (14.17)
380 (14.96)
POWER
LINK
ALM
JX5
JF1/ENC
CX29
MCC
CX30
ESP
CXA20
DCOH
CAUTION
CX5 X
HIGHVOLTAGE
DISCHARGE
TIME
2 min
>
SW
OPTIONAL
ENCODER
BATTERY
CASE
10 (0.39)
BATTERY
C24 (FRONT)
C25 (CENTER)
C26 (REAR)
C24
A
L2
B L3 L1
C25
V
W U
C26
RI RC
RE RC
PULL
HERE
30 (1.18)
60 (2.36)
172 (6.77)
100 (3.94) max.
Dimensions shown in mm (in).
βi Series Servo Amplifiers Electrical Specifications
Model
βSVM1-40i
βSVM1-10HVi
βSVM1-20HVi
βSVM1-40HVi
Rated output current (rms amps)
12
3.1
5.6
9.2
Current limit (Peak amps)
40
10
20
40
AC Power
1-phase
n/an/an/an/a
3-phase
200-240 VAC, 50/60 Hz ± 2 Hz
400-480 VAC
400-480 VAC
400-480 VAC
DC Control Power (per amplifier)
24 VDC ± 10% @ 0.9 Amp
24 VDC ± 10% @ 0.9 Amp
24 VDC ± 10% @ 0.9 Amp
24 VDC ± 10% @ 0.9 Amp
Max. Heat loss (watts)
100
54
82
122
Regenerative discharge
50W50W50W50W
Maintenance Clearances:
50 (1.97)
n/a
Above and below amplifier
Beside and between amplifiers
50 (1.97)
n/a
50 (1.97)
n/a
50 (1.97)
n/a
*These values are standard values at 20°C with a tolerance of ±10%. The speed-torque characteristics vary depending on the parameter setting and input voltage of the digital servo amplifiers.
(The above figures show average values.) These values may be changed without prior notice.
5.66
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Motors
βi Series Servo Amplifiers
βSVM1-20i Connection Diagram
>
DISCHARGE TIME 2 min
CAUTION
1
HIGH
VOLTAGE
No. Name
1
2
CZ7-1
3
CZ7-2
4
CZ7-3
5
CX29
6
CX30
7
CXA20
8
CXA19B
9
CXA19A
10
COP10B
11
COP10A
12
ALM
13
JX5
14
LINK
15
JF1
16
POWER
17
CX5X
18
8
FANUC
regulated power
supply 24 VDC
(See Note 2)
Connector Location
CXA19B
Remarks
DC link charge LED
Main power input connector
Discharge resistor connector
Motor power connector
Connector for main power
MCC control signal
E-Stop signal connector
Regenerative resistor
overtemperature switch connector
24 VDC power input
24 VDC power input
Fiber optic servo command input
Fiber optic servo command output
Servo alarm status LED
Reserved
Fiberoptic link status LED
Serial Encoder Feedback
Control power status display LED
Absolute encoder battery
Tapped hole for
grounding the amplifier
9
E-Stop and 24 VDC
to next amplifier
CXA19A
optical fiber cable
panel mounted
battery case
(See Note 3)
10
PACMotion PMM335
motion controller
COP10B
IC800ABK001
L2/L1
/L3
11
16
DCC/DCP
V/U
circuit
breaker
magnetic
contactor
AC line
filter
POWER
14 LINK
ALM
12
/W
CZ7
discharge
resistor with
built-in thermostat
2
3
fiber optic command
to next amplifier
COP10A
LED
13
optical cable
JX5
4
CX29
MCC 5
ZA06B-6130-H401
ZA06B-6130-H402
CX30
6
ESP
JF1/ENC
machine emergency
stop switch
CXA20
DCOH
17
CX5X
amplifier mounted
battery case
IC800BBK021
(See Note 3)
15
7
18
power
encoder
βi Series
motor
file name: DIM_aSeriesBatteryPk.eps
optional 24 V power
current
page
supply for motor
brake in catalog: 45
(See Note 2)
source: GFH-001 pg 13
Ø4.3 (0.169) Mounting hole (x4)
IC800ABK001 Encoder Battery Kit Dimensions
Key:
+
A
3-M3 negative terminals
B
Negative terminal indication
C
Positive terminal indication
D
3-M3 positive terminals
E
4-Ø4.3 (0.169) mounting holes
78
(3.07)
93
(3.66)
D
A
103
(4.06)
B C
–
+
92.2
(3.630)
106.3
(4.185)
40
(1.57)
78
(3.07)
103
(4.06)
IC800ABK001 Absolute encoder battery pack
Notes:
1. Always install the circuit breakers, magnetic contactor, and AC line filter.
2. Use a regulated 24 VDC power supply for the amplifier. 24 VDC power supply for the amplifier and power supply for the motor
brake cannot be shared.
3. The IC800ABK001 encoder battery pack mounts separately on the panel and can power up to 4 axes. Alternatively, the
IC800BBK021 1-axis lithium battery can be snapped onto each amplifier.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
DIM_aSeriesBatteryPk.eps
5.67
Servo Motors
Motion Control Systems
βi Series Servo Amplifiers
βSVM1-40i Connection Diagram
βSVM1-10HVi
βSVM1-20HVi
βSVM1-40HVi
FANUC
FANUC LTD
Yamenashi 401-0597 JAPAN
1
regulated power
supply 24 VDC
(See Note 2)
CAUTION
CXA19B
PACMotion PMM335
motion controller
10
COP10B
11
COP10A
12
17
LED
optical fiber cable
15
13
9
CXA19A
POWER
LINK
ALM
JX5
14
E-Stop and 24 VDC
to next amplifier
panel mounted
battery case
(See Note 3)
IC800ABK001
16
2
machine emergency
stop switch
3
4
5
18
JF1/ENC
CX29
CX5X
MCC
CX30 CAUTION
HIGHVOLTAGE
ESP
DISCHARGE
2 min
CXA20 TIME
DCOH
SW
fiber optic command
to next amplifier
>
optical cable
amplifier mounted
battery case
IC800BBK021
(See Note 3)
discharge
resistor with
built-in thermostat
(see Note 4)
ENCODER
BATTERY
BATTERY
circuit
breaker
magnetic
contactor
AC line
filter
6
CZ4 (FRONT)
CZ5 (CENTER)
CZ6 (REAR)
C24
A
L2
B L3 L1
C25
V
W U
8
C26
RI RC
RE RC
7
PULL
HERE
Connector Location
No. 19
power
optional 24 V power
supply for motor brake
(See Note 2)
encoder
βi Series
motor
Notes:
1. Always install the circuit breakers, magnetic contactor, and AC line filter.
2. Use a regulated 24 VDC power supply for the amplifier. 24 VDC power
supply for the amplifier and power supply for the motor brake cannot
be shared.
3. The IC800ABK001 encoder battery pack mounts separately on the panel
and can power up to 4 axes. Alternatively, the IC800BBK021 1-axis lithium
battery can be snapped onto each amplifier.
4. The BSVM1-40i can use the ZA06B-6089-H500 or ZA06B-6089-H713 resistors. All Beta HVi series amplifiers must use optional ZA06B-6130-H403
resistor when external regeneration capacity is required.
5.68
GE Intelligent Platforms Control Systems Solutions
Name
1
2
CX29
3
CX30
4
CXA20
5
SW
6
CZ4
7
CZ5
8
CZ6
9
CXA19B
10
CXA19A
11
COP10B
12
COP10A
13
ALM
14
JX5
15
LINK
16
JF1
17
POWER
18
CX5X
19
Remarks
DC link charge LED
Connector for main power
MCC control signal
E-Stop signal connector
Regenerative resistor
overtemperature switch connector
Setting switch (DC alarm level)
Main power input connector
Motor power connector
Discharge resistor connector
24 VDC power input
24 VDC power input
Fiber optic servo command input
Fiber optic servo command output
Servo alarm status LED
Reserved
Fiberoptic link status LED
Serial Encoder Feedback
Control power status display LED
Absolute encoder battery
Tapped hole for
grounding the amplifier
www.ge-ip.com
Motion Control Systems
Servo Motors
βi Series Servo Amplifiers
Ordering Information
The βi series amplifiers can be ordered as individual components
or as kits that include connectors, regenerative discharge resistor
and spare fuses. The kit is recommended for new installation
while spare parts, or replacement units, should use the amplifier
only model number.
To place an order for a complete servo system, select the Servo
Motor that meets your application requirements, then select the
amplifier kit, cables or connectors (customer built cables) and
accessories.
βi and βHVi Series Servo Amplifier Kits*
Part Number
Qty. Kit Contents
IC800BIK020
1βSVM1-20i Amplifier (ZA06B-6130-H002)
20 Amp βi Series Amplifier Package
1
20 W Regenerative Discharge Resistor (ZA06B-6130-H401)
1
Spare 24 VDC Fuse (ZA06B-6073-K250)
1
CZ7 Power Connector Kit (ZA06B-6130-K200)
2
CXA19 24 VDC Connector Kit (ZA06B-6130-K201)
1
CXA20 Regenerative Discharge Thermostat Connector Kit
(ZA06B-6130-K202)
1
CX29 MCC Connector Kit (ZA06B-6130-K203)
1
CX30 E-Stop Connector Kit (ZA06B-6130-K204)
IC800BIK040
1βSVM1-40i Amplifier (ZA06B-6130-H003)
40 Amp βi Series Amplifier Package
1
Spare 24 VDC Fuse (ZA06B-6073-K250)
1
CZ4 Power Connector Kit (ZA06B-6110-K200#XXS)
1
CZ5 Motor Power Connector Kit (ZA06B-6110-K202#YYS)
1
CZ6 Regenerative Discharge Resistor Connector Kit
(ZA06B-6110-K201#XYM)
2
CXA19 24 VDC Connector Kit (ZA06B-6130-K201)
1
CXA20 Regenerative Resistor Thermostat Connector Kit (ZA06B-6130-K202)
1
CX29 MCC Connector Kit (ZA06B-6130-K203)
1
CX30 E-Stop Connector Kit (ZA06B-6130-K204)
IC800BIHV010
1 βSVM1-10HVi Amplifier (ZA06B-6131-H001)
10 Amp βHVi Series Amplifier Package
1
Spare 24 VDC Fuse (ZA06B-6073-K250)
1
CZ4 Power Connector Kit (ZA06B-6110-K200#XXS)
1
CZ5 Motor Power Connector Kit (ZA06B-6110-K202#YYS)
1
CZ6 Regenerative Discharge Resistor Connector Kit
(ZA06B-6110-K201#XYM)
2
CXA19 24 VDC Connector Kit (ZA06B-6130-K201)
1
CXA20 Regenerative Resistor Thermostat Connector Kit
(ZA06B-6130-K202)
1
CX29 MCC Connector Kit (ZA06B-6130-K203)
1
CX30 E-Stop Connector Kit (ZA06B-6130-K204)
IC800BIHV020
1 βSVM1-20HVi Amplifier (ZA06B-6131-H002)
20 Amp βHVi Series Amplifier Package
1
Spare 24 VDC Fuse (ZA06B-6073-K250)
1
CZ4 Power Connector Kit (ZA06B-6110-K200#XXS)
1
CZ5 Motor Power Connector Kit (ZA06B-6110-K202#YYS)
1
CZ6 Regenerative Discharge Resistor Connector Kit
(ZA06B-6110-K201#XYM)
2
CXA19 24 VDC Connector Kit (ZA06B-6130-K201)
1
CXA20 Regenerative Resistor Thermostat Connector Kit (ZA06B-6130-K202)
1
CX29 MCC Connector Kit (ZA06B-6130-K203)
1
CX30 E-Stop Connector Kit (ZA06B-6130-K204)
IC800BIHV040
1 βSVM1-40HVi Amplifier (ZA06B-6131-H003)
40 Amp βHVi Series Amplifier Package
1
Spare 24 VDC Fuse (ZA06B-6073-K250)
1
CZ4 Power Connector Kit (ZA06B-6110-K200#XXS)
1
CZ5 Motor Power Connector Kit (ZA06B-6110-K202#YYS)
1
CZ6 Regenerative Discharge Resistor Connector Kit (ZA06B-6110-K201#XYM)
2
24 VDC Connector Kit (ZA06B-6130-K201 CXA19)
1
CXA20 Regenerative Resistor Thermostat Connector Kit (ZA06B-6130-K202)
1
CX29 MCC Connector Kit (ZA06B-6130-K203)
1
CX30 Estop Connector Kit (ZA06B-6130-K204)
1
Amplifier cooling fan kit (ZA06B-6134-K002)
Holding Brake: For system designs which
include a vertical axis that must hold its
position when power is removed, a motor
holding brake option is available. User
supplied 24VDC power is required. To
connect to the power, a separate brake
cable is required on all motors except
β2is, β4is, β2HVis and β4HVis models.
Encoder Battery Kit: All βis Series Servo
motors feature a built-in serial encoder
that can be used in either incremental or
absolute mode. In order to utilize the
absolute capability, an optional encoder
battery pack must be installed. This pack
allows the encoder’s position information
to be retained so that the machine does
not need to be referenced to a home
position every time power is restored to
the system.
The 1-axis battery pack includes a small
lithium battery and case which snaps on
the amplifier unit. The 4-axis battery pack
is panel mounted and uses standard
D-cell batteries.
Battery Kits
Part Number Qty. Kit Contents
IC800BBK021 1
Lithium Battery (ZA06B-6093-K001)
1-Axis βi
1
Battery Holder (ZA06B-6093-K002)
Battery Kit
IC800ABK001 4
D-Cell Alkaline Battery
4-Axis D-Cell (ZA98L-0031-0005)
Panel Mounted 1
Panel Mounted Battery Pack
Battery Pack
(ZA06B-6050-K060)**
IC800ABK002 1
Lithium Battery (ZA06B-6114-K504)
1-Axis αHVi
1
Battery Holder (ZA06B-6114-K505)
Battery Kit
IC800ABK003 1
Lithium Battery (ZA06B-6114-K504)
1-Axis αHVi
1
Battery Holder (ZA06B-6114-K506)
Battery Kit for
αSVM-180HVi
Amplifier
*Amplifier kits provide all of the required amplifier components for complete installation; we strongly encourage kits be ordered for new
systems. Separate amplifiers are available for spare or replacement units.
**See dimensions of battery pack on page 76
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.69
Servo Motors
Motion Control Systems
βHVi Series Servo Amplifier and βHVis Series Servo Motor
Ordering Information
Model Number
β2/4000HVis
Servo Motor
Servo Motor w/ Holding Brake
Amplifier Kit
Amplifier Only
ZA06B-0062-B203
ZA06B-0062-B503
IC800BIHV010
ZA06B-6131-H001
β4/4000HVis
β8/3000HVis
β12/3000HVis
β22/2000HVis
ZA06B-0064-B203
ZA06B-0064-B503
IC800BIHV010
ZA06B-6131-H001
ZA06B-0076-B203
ZA06B-0076-B503
IC800BIHV010
ZA06B-6131-H001
ZA06B-0079-B203
ZA06B-0079-B503
IC800BIHV020
ZA06B-6131-H002
ZA06B-0086-B203
ZA06B-0086-B503
IC800BIHV020
ZA06B-6131-H002
Cables and Accessories Ordering Information
Model Number
β2/4000HVis
β4/4000HVis
β8/3000HVis
β12/3000HVis
β22/2000HVis
Power Cable
7 M
CP2I-0WPB-0070-AZ
CP2I-0WPB-0070-AZ
CP3I-0WPB-0070-AZ CP3I-0WPB-0070-AZ
CP4I-0WPB-0070-AZ
14 M
CP2I-0WPB-0140-AZ
CP2I-0WPB-0140-AZ
CP3I-0WPB-0140-AZ CP3I-0WPB-0140-AZ
CP4I-0WPB-0140-AZ
Power Cable (Shielded)
7 M
CP2I-0WEB-0070-AZ
CP2I-0WEB-0070-AZ
CP3I-0WEB-0070-AZ CP3I-0WEB-0070-AZ
CP4I-0WEB-0070-AZ
14 M
CP2I-0WEB-0140-AZ
CP2I-0WEB-0140-AZ
CP3I-0WEB-0140-AZ CP3I-0WEB-0140-AZ
CP4I-0WEB-0140-AZ
Feedback Cable
7 M
CFDA-7WPB-0070-AZ CFDA-7WPB-0070-AZ CFDA-7WPB-0070-AZ CFDA-7WPB-0070-AZ CFDA-7WPB-0070-AZ
(Right Angle Motor Connector)
14 M CFDA-7WPB-0140-AZ CFDA-7WPB-0140-AZ CFDA-7WPB-0140-AZ CFDA-7WPB-0140-AZ CFDA-7WPB-0140-AZ
Feedback Cable
7 M
CFDA-0WPB-0070-AZ CFDA-0WPB-0070-AZ CFDA-0WPB-0070-AZ CFDA-0WPB-0070-AZ CFDA-0WPB-0070-AZ
(Straight Motor Connector)
14 M CFDA-0WPB-0140-AZ CFDA-0WPB-0140-AZ CFDA-0WPB-0140-AZ CFDA-0WPB-0140-AZ CFDA-0WPB-0140-AZ
Holding Brake Power Cable
7 M
Integrated with
Integrated with CB4N-0WPM-0070-AZCB4N-0WPM-0070-AZCB4N-0WPM-0070-AZ
Power Cable
Power Cable
14 M
CB4N-0WPM-0140-AZCB4N-0WPM-0140-AZCB4N-0WPM-0140-AZ
External Regen Resistors
ZA06B-6130-H403
ZA06B-6130-H403
ZA06B-6130-H403
ZA06B-6130-H403
ZA06B-6130-H403
CZ4 Power Connector Kit
ZA06B-6110-K200#XXS ZA06B-6110-K200#XXS ZA06B-6110-K200#XXS ZA06B-6110-K200#XXS ZA06B-6110-K200#XXS
CZ5 Motor Power Connector Kit
ZA06B-6110-K202#YYS ZA06B-6110-K202#YYS ZA06B-6110-K202#YYS ZA06B-6110-K202#YYS ZA06B-6110-K202#YYS
CZ6 Regen Resistor Thermostat
ZA06B-6110-K201#XYM ZA06B-6110-K201#XYMZA06B-6110-K201#XYMZA06B-6110-K201#XYMZA06B-6110-K201#XYM
Connector Kit
CXA19 Connector Kit
ZA06B-6130-K201
ZA06B-6130-K201
ZA06B-6130-K201
ZA06B-6130-K201
ZA06B-6130-K201
CXA20 Regen Thermostat
ZA06B-6130-K202 ZA06B-6130-K202ZA06B-6130-K202ZA06B-6130-K202ZA06B-6130-K202
Connector Kit
CX29 MCC Connector Kit
ZA06B-6130-K203
ZA06B-6130-K203
ZA06B-6130-K203
ZA06B-6130-K203
ZA06B-6130-K203
CX30 Estop Input Connector Kit
ZA06B-6130-K204
ZA06B-6130-K204
ZA06B-6130-K204
ZA06B-6130-K204
ZA06B-6130-K204
Motor Feedback Connector Kit 90 Deg ZA06B-6114-K204#E ZA06B-6114-K204#E ZA06B-6114-K204#E ZA06B-6114-K204#E ZA06B-6114-K204#E
StraightZA06B-6114-K204#S ZA06B-6114-K204#S ZA06B-6114-K204#S ZA06B-6114-K204#S ZA06B-6114-K204#S
Motor Half Key (Note 2)
Z44A730465-001 Z44A730465-016Z44A730465-002Z44A730465-015Z44A730465-003
Motor Power/Brake 90 Deg ZA06B-6114-K220#E ZA06B-6114-K220#E
N/A
N/A
N/A
Connector Kit
Straight ZA06B-6114-K220#S ZA06B-6114-K220#S
N/A
N/A
N/A
Motor Power Connector Kit
90 Deg
N/A
N/A
Z44A730464-G18
Z44A730464-G18
Z44A730464-G20
Straight N/A
N/A
Z44A730464-G17Z44A730464-G17Z44A730464-G19
Motor Brake Connector Kit
90 Deg
N/A
N/A
ZA06B-6114-K213#E ZA06B-6114-K213#E ZA06B-6114-K213#E
Straight
N/A
N/A
ZA06B-6114-K213#SZA06B-6114-K213#SZA06B-6114-K213#S
Spare Control Power Fuse
ZA06B-6073-K250
Encoder Battery Kits
1 axis
IC800BBK021 (Note 1)
4 axis
IC800ABK001 (Note 1)
Fiberoptic Command Cable
15 cm
ZA66L-6001-0023#L150R0
1 M
ZA66L-6001-0023#L1R003
2 M
ZA66L-6001-0023#L2R003
3 M
ZA66L-6001-0023#L3R003
Sheathed Fiberoptic Cable
1 M
ZA66L-6001-0026#L1R003
5 M
ZA66L-6001-0026#L5R003
10 M
ZA66L-6001-0026#L10R03
20 M
ZA66L-6001-0026#L20R03
30MZA66L-6001-0026#L30R03
50MZA66L-6001-0026#L50R03
100 M
ZA66L-6001-0026#L100R3
Feedback Connector (JF1)
ZA06B-6073-K214
AC Line Filter
5.4 kW
ZA81L-0001-0168
10.5 kW
ZA81L-0001-0169
Replacement Encoder BatteryZA06B-6093-K001 (IC800BBK021 kit); ZA98L-0031-0005 (IC800ABK001 kit)
1) The IC800ABPK001 panel mounted encoder battery pack requires CXA19 connector kit for user supplied cable. Uses 4 D-cell batteries. See breakdown of kit contents in the Ordering Information section.
2) Half Keys are used to fill the motor shaft Keyway when a compression type coupling is used in order to preserve the rotational balance of the motor.
5.70
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Motors
βi Series Servo Amplifier and βi Series Servo Motor
Ordering Information
Model Number
β0.4/5000is
β0.5/6000is
β1/6000is
β2/4000is
Servo Motor
ZA06B-0114-B203
ZA06B-0115-B203
ZA06B-0116-B203
ZA06B-0061-B203
Servo Motor w/ Holding Brake
ZA06B-0114-B503
ZA06B-0115-B503
ZA06B-0116-B503
ZA06B-0061-B503
Amplifier Kit
IC800BIK020
IC800BIK020
IC800BIK020
IC800BIK020
Amplifier Only
ZA06B-6130-H002
ZA06B-6130-H002
ZA06B-6130-H002
ZA06B-6130-H002
Amplifier Fan Kit (Note 1)N/A N/A N/A N/A
Cables and Accessories Ordering Information
Model Number
β0.4/5000is
β0.5/6000is
β1/6000is
β2/4000is
Power Cable
7 M
CP8B-1WPB-0070-AZ
CP8B-1WPB-0070-AZ
CP8B-1WPB-0070-AZ
CP9B-0WPB-0070-AZ
14 M
CP8B-1WPB-0140-AZ
CP8B-1WPB-0140-AZ
CP8B-1WPB-0140-AZ
CP9B-0WPB-0140-AZ
Power Cable (Shielded)
7 M
CP8B-1WEB-0070-AZ
CP8B-1WEB-0070-AZ
CP8B-1WEB-0070-AZ
CP9B-0WEB-0070-AZ
14 M
CP8B-1WEB-0140-AZ
CP8B-1WEB-0140-AZ
CP8B-1WEB-0140-AZ
CP9B-0WEB-0140-AZ
Feedback Cable (Right Angle motor connector) 7 M
CFDA-7WPB-0070-AZ
CFDA-7WPB-0070-AZ
CFDA-7WPB-0070-AZ
CFDA-7WPB-0070-AZ
14 M
CFDA-7WPB-0140-AZ
CFDA-7WPB-0140-AZ
CFDA-7WPB-0140-AZ
CFDA-7WPB-0140-AZ
Feedback Cable (Straight motor connector) 7 M
CFDA-0WPB-0070-AZ
CFDA-0WPB-0070-AZ
CFDA-0WPB-0070-AZ
CFDA-0WPB-0070-AZ
14 M
CFDA-0WPB-0140-AZ
CFDA-0WPB-0140-AZ
CFDA-0WPB-0140-AZ
CFDA-0WPB-0140-AZ
Holding Brake Power Cable
7 M
CB6N-5WPM-0070-AZ
CB6N-5WPM-0070-AZ
CB6N-5WPM-0070-AZ Integrated with Power Cable
14 M
CB6N-5WPM-0140-AZ
CB6N-5WPM-0140-AZ
CB6N-5WPM-0140-AZ Integrated with Power Cable
External Regen Resistors
20 W
ZA06B-6130-H401
ZA06B-6130-H401
ZA06B-6130-H401
ZA06B-6130-H401
100 W
ZA06B-6130-H402
ZA06B-6130-H402
ZA06B-6130-H402
ZA06B-6130-H402
200 W
N/A
N/A
N/A
N/A
800 W
N/A
N/A
N/A
N/A
CZ7 Power Connector Kit
ZA06B-6130-K200
ZA06B-6130-K200
ZA06B-6130-K200
ZA06B-6130-K200
CZ4 Power Connector Kit
N/A
N/A
N/A
N/A
CZ5 Motor Power Connector Kit
N/A
N/A
N/A
N/A
CZ6 Regen Resistor Thermostat Connector Kit N/A
N/A
N/A
N/A
CXA19 24 VDC Connector Kit
ZA06B-6130-K201
ZA06B-6130-K201
ZA06B-6130-K201
ZA06B-6130-K201
CXA20 Regen Thermostat Connector Kit
ZA06B-6130-K202
ZA06B-6130-K202
ZA06B-6130-K202
ZA06B-6130-K202
CX29 MCC Connector Kit
ZA06B-6130-K203
ZA06B-6130-K203
ZA06B-6130-K203
ZA06B-6130-K203
CX30 E-Stop Input Connector Kit
ZA06B-6130-K204
ZA06B-6130-K204
ZA06B-6130-K204
ZA06B-6130-K204
Motor Feedback Connector Kit
90 Deg
ZA06B-6114-K204#E
ZA06B-6114-K204#E
ZA06B-6114-K204#E
ZA06B-6114-K204#E
StraightZA06B-6114-K204#S ZA06B-6114-K204#S ZA06B-6114-K204#SZA06B-6114-K204#S
Motor Half Key (Note 3)
Z44A730465-013 Z44A730465-013 Z44A730465-011Z44A730465-001
Motor Power/Brake Connector Kit
90 Deg
N/A
N/A
N/A
ZA06B-6114-K220#E
StraightN/A
N/A
N/AZA06B-6114-K220#S
Motor Power Connector Kit
90 Deg
ZA06B-6114-K230#E
ZA06B-6114-K230#E
ZA06B-6114-K230#E
N/A
StraightZA06B-6114-K230#S ZA06B-6114-K230#S ZA06B-6114-K230#S
N/A
Motor Brake Power Connector Kit
90 Deg
ZA06B-6114-K232#E
ZA06B-6114-K232#E
ZA06B-6114-K232#E
N/A
StraightZA06B-6114-K232#S ZA06B-6114-K232#S ZA06B-6114-K232#S
N/A
Spare Amplifier Control Power Fuse
ZA06B-6073-K250
Encoder Battery Kits
1 axis
IC800BBK021 (Note 2)
4 axis
IC800ABK001 (Note 2)
Fiberoptic Command Cable
15 cm
ZA66L-6001-0023#L150R0
1 M
ZA66L-6001-0023#L1R003
2 M
ZA66L-6001-0023#L2R003
3 M
ZA66L-6001-0023#L3R003
Fiberoptic Command Cable (sheathed)
1 M
ZA66L-6001-0026#L1R003
5 M
ZA66L-6001-0026#L5R003
10 M
ZA66L-6001-0026#L10R03
20 M
ZA66L-6001-0026#L20R03
30 M
ZA66L-6001-0026#L30R03
50 M
ZA66L-6001-0026#L50R03
100 M
ZA66L-6001-0026#L100R3
Amplifier Feedback Connector (JF1)
ZA06B-6073-K214
AC Line Filter
5.4 kW
ZA81L-0001-0083#3C
10.5 kW
ZA81L-0001-0101#C
Replacement Encoder BatteryZA06B-6093-K001 (IC800BBK021 kit); ZA98L-0031-0005 (IC800ABK001 kit)
1) Separate user installed cooling fan is only required for the βSVM1-20i amplifier and β8/3000is motor or when single phase supply is used with the β4/4000is motor
2) The IC800ABK001 panel mounted encoder battery pack requires CXA19 connector kit for user supplied cable. Uses 4 D-cell batteries. See breakdown of kit contents in the Ordering Information section.
3) Half Keys are used to fill the motor shaft Keyway when a compression type coupling is used in order to preserve the rotational balance of the motor.
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.71
Servo Motors
Motion Control Systems
βi Series Servo Amplifier and βi Series Servo Motor
Ordering Information
β4/4000is
Model Number
Servo Motor
Servo Motor w/ Holding Brake
Amplifier Kit
Amplifier Only
Amplifier Fan Kit (Note 1)
β8/3000is
β12/3000is
ZA06B-0063-B203
ZA06B-0075-B203
ZA06B-0078-B203
ZA06B-0063-B503
ZA06B-0075-B503
ZA06B-0078-B503
IC800BIK020
IC800BIK020
IC800BIK040
ZA06B-6130-H002
ZA06B-6130-H002
ZA06B-6130-H003
ZA06B-6134-K003ZA06B-6134-K003
N/A
β22/2000is
ZA06B-0085-B203
ZA06B-0085-B503
IC800BIK040
ZA06B-6130-H003
N/A
Cables and Accessories Ordering Information
Model Number
β4/4000is
β8/3000is
β12/3000is
β22/2000is
Power Cable
7 M
CP9B-0WPB-0070-AZ
CP3B-0WPB-0070-AZ
CP5B-0WPB-0070-AZ
CP6B-0WPB-0070-AZ
14 M
CP9B-0WPB-0140-AZ
CP3B-0WPB-0140-AZ
CP5B-0WPB-0140-AZ
CP6B-0WPB-0140-AZ
Power Cable (Shielded)
7 M
CP9B-0WEB-0070-AZ
CP3B-0WEB-0070-AZ
CP5B-0WEB-0070-AZ
CP6B-0WEB-0070-AZ
14 M
CP9B-0WEB-0140-AZ
CP3B-0WEB-0140-AZ
CP5B-0WEB-0140-AZ
CP6B-0WEB-0140-AZ
Feedback Cable (Right Angle motor connector) 7 M
CFDA-7WPB-0070-AZ
CFDA-7WPB-0070-AZ
CFDA-7WPB-0070-AZ
CFDA-7WPB-0070-AZ
14 M
CFDA-7WPB-0140-AZ
CFDA-7WPB-0140-AZ
CFDA-7WPB-0140-AZ
CFDA-7WPB-0140-AZ
Feedback Cable (Straight motor connector) 7 M
CFDA-0WPB-0070-AZ
CFDA-0WPB-0070-AZ
CFDA-0WPB-0070-AZ
CFDA-0WPB-0070-AZ
14 M
CFDA-0WPB-0140-AZ
CFDA-0WPB-0140-AZ
CFDA-0WPB-0140-AZ
CFDA-0WPB-0140-AZ
Holding Brake Power Cable
7 M
Integrated with Power CableCB4N-0WPM-0070-AZ CB4N-0WPM-0070-AZ CB4N-0WPM-0070-AZ
14 M
Integrated with Power CableCB4N-0WPM-0140-AZ CB4N-0WPM-0140-AZ CB4N-0WPM-0140-AZ
External Regen Resistors
20 W
ZA06B-6130-H401
ZA06B-6130-H401
N/A
N/A
100 W
ZA06B-6130-H402
ZA06B-6130-H402
N/A
N/A
200 W
N/A
N/A
ZA06B-6089-H500
ZA06B-6089-H500
800 W
N/A
N/A
ZA06B-6089-H713
ZA06B-6089-H713
CZ7 Power Connector Kit
ZA06B-6130-K200
ZA06B-6130-K200
N/A
N/A
CZ4 Power Connector Kit
N/A
N/A
ZA06B-6110-K200#XXS ZA06B-6110-K200#XXS
CZ5 Motor Power Connector Kit
N/A
N/A
ZA06B-6110-K202#YYS ZA06B-6110-K202#YYS
CZ6 Regen Resistor Thermostat Connector Kit
N/A
N/A
ZA06B-6110-K201#XYMZA06B-6110-K201#XYM
CXA19 24 VDC Connector Kit
ZA06B-6130-K201
ZA06B-6130-K201
ZA06B-6130-K201
ZA06B-6130-K201
CXA20 Regen Thermostat Connector Kit
ZA06B-6130-K202
ZA06B-6130-K202
ZA06B-6130-K202
ZA06B-6130-K202
CX29 MCC Connector Kit
ZA06B-6130-K203
ZA06B-6130-K203
ZA06B-6130-K203
ZA06B-6130-K203
CX30 E-Stop Input Connector Kit
ZA06B-6130-K204
ZA06B-6130-K204
ZA06B-6130-K204
ZA06B-6130-K204
Motor Feedback Connector Kit
90 Deg
ZA06B-6114-K204#E
ZA06B-6114-K204#E
ZA06B-6114-K204#E
ZA06B-6114-K204#E
StraightZA06B-6114-K204#S ZA06B-6114-K204#S ZA06B-6114-K204#SZA06B-6114-K204#S
Motor Half Key (Note 3)
Z44A730465-016 Z44A730465-002 Z44A730465-015Z44A730465-003
Motor Power/Brake Connector Kit
90 Deg
ZA06B-6114-K220#E
N/A
N/A
N/A
StraightZA06B-6114-K220#S
N/A
N/A
N/A
Motor Power Connector Kit
90 Deg
N/A
Z44A730464-G18
Z44A730464-G18
Z44A730464-G20
Straight
N/A
Z44A730464-G17 Z44A730464-G17Z44A730464-G19
Motor Brake Power Connector Kit
90 Deg
N/A
ZA06B-6114-K213#E
ZA06B-6114-K213#E
ZA06B-6114-K213#E
Straight
N/A
ZA06B-6114-K213#S ZA06B-6114-K213#SZA06B-6114-K213#S
Spare Amplifier Control Power Fuse
ZA06B-6073-K250
Encoder Battery Kits
1 axis
IC800BBK021 (Note 2)
4 axis
IC800ABK001 (Note 2)
Fiberoptic Command Cable
15 cm
ZA66L-6001-0023#L150R0
1 M
ZA66L-6001-0023#L1R003
2 M
ZA66L-6001-0023#L2R003
3 M
ZA66L-6001-0023#L3R003
Fiberoptic Command Cable (sheathed)
1 M
ZA66L-6001-0026#L1R003
5 M
ZA66L-6001-0026#L5R003
10 M
ZA66L-6001-0026#L10R03
20 M
ZA66L-6001-0026#L20R03
30 M
ZA66L-6001-0026#L30R03
50 M
ZA66L-6001-0026#L50R03
100 M
ZA66L-6001-0026#L100R3
Amplifier Feedback Connector (JF1)
ZA06B-6073-K214
AC Line Filter
5.4 kW
ZA81L-0001-0083#3C
10.5 kW
ZA81L-0001-0101#C
Replacement Encoder BatteryZA06B-6093-K001 (IC800BBK021 kit); ZA98L-0031-0005 (IC800ABK001 kit)
1) Separate user installed cooling fan is only required for the βSVM1-20i amplifier and β8/3000is motor or when single phase supply is used with the β4/4000is motor
2) The IC800ABK001 panel mounted encoder battery pack requires CXA19 connector kit for user supplied cable. Uses 4 D-cell batteries. See breakdown of kit contents in the Ordering Information section.
3) Half Keys are used to fill the motor shaft Keyway when a compression type coupling is used in order to preserve the rotational balance of the motor.
5.72
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Motors
βis Series Servo Motors
Specifications
Motor Model
Unit
β0.4/5000is
Cont Stall Torque*
in-lb (Nm)
3.5 (0.4)
Peak Torque*
in-lb (Nm)
8.9 (1)
0.885 Rotor Inertia
in-lb-s2 x 10-4
(kg-m2 x 10-4)(0.1)
Rated Speed
RPM
4000
No Load Speed
RPM
5000
Encoder Resolution
Counts/Rev
65,536
Flange Size
mm
60
β0.5/6000is
β1/6000is
β2/4000is
β4/4000is
5.8 (0.65)
10.6 (1.2)
17.7 (2)
22.1 (2.5)
44.3 (5)
62 (7)
1.593 3.009
25.76 (0.18)
(0.34) (2.91)
6000
6000
4000
6000
6000
4000
65,536
65,536
131,072
60
60
90
β8/3000is β12/3000is β22/2000is
31 (3.5)
62 (7)
88.5 (10)
132.8 (15)
45.58 103.55 (5.15) (11.7)
3000
2000
4000
3000
131,072
131,072
90
130
97.4 (11)
177 (20)
239 (27)
398.3 (45)
201.80 466.43 (22.8)
(52.7)
2000
2000
3000
2000
131,072
131,072
130
174
Mechanical Data
Weight
Axial Load Rating
Radial Load Rating
Mechanical Time Constant
Thermal Time Constant
Static Friction lb (kg)
lb (kg)
lb (kg)
msec
min
Nm
1.76 (0.8)
11 (5)
44 (20)
1
8
0.04
2.2 (1)
11 (5)
44 (20)
0.9
10
0.04
3.3 (1.5)
11 (5)
44 (20)
0.7
15
0.04
6.16 (2.8)
17.6 (8)
55 (25)
4
15
0.1
9.46 (4.3)
17.6 (8)
55 (25)
3
20
0.2
16.28 (7.4)
44 (20)
154 (70)
3
20
0.3
26.18 (11.9)
44 (20)
154 (70)
2
25
0.4
37.4 (17)
132 (60)
440 (200)
2
30
0.8
Electrical Data
Torque Constant*
in-lb/A (Nm/A)
0.99 (0.11)
1.97 (0.22)
3.98 (0.45)
5.49 (0.62)
6.64 (0.75)
10.27 (1.16)
9.56 (1.08)
15.66 (1.77)
Resistance*
ohms0.55 0.85 1.5 1.6 0.94 1 0.39 0.44
7.7 15.4 21 26 41
38
62
Back EMF*
V(rms)/krpm4
Rated Motor Power*
HP (kW)
0.17 (0.13)
0.47 (0.35)
0.67 (0.5)
0.67 (0.5)
1 (0.75)
1.6 (1.2)
2.4 (1.8)
3.4 (2.5)
Cont. Stall Current
A (rms)3.6 2.9 2.7 3.3 4.7 6 10.2 11.3
20 20 20 20 20 40 40
Max Current
A (peak)20
Insulation
Class F
Class F
Class F
Class F
Class F
Class F
Class F
Class F
Amplifier Model
Amp Model Number
βSVM1-20i
βSVM1-20i
βSVM1-20i
βSVM1-20i
βSVM1-20i
βSVM1-20i
βSVM1-40i
βSVM1-40i
Brake Data
Holding Torque
in-lb (Nm)
5.8 (0.65)
5.8 (0.65)
10.6 (1.2)
26.6 (3)
26.6 (3)
70.8 (8)
70.8 (8)
309.8 (35)
Inertia Adder
in-lb-s2 x 10-4
0.797 (0.09)
0.797 (0.09)
1.770 (0.2)
1.770 (0.2)
6.195 (0.7)
6.195 (0.7)
53.100 (6)
(kg-m2 x 10-4)0.797 (0.09)
Weight Adder
lb (kg)
0.88 (0.4)
0.88 (0.4)
0.88 (0.4)
2.2 (1)
2.2 (1)
4.84 (2.2)
4.84 (2.2)
13.2 (6)
Current
A 0.5 0.5 0.5 0.9 0.91.1 1.1 1.2
Voltage
VDC24 24 24 24 24 24 24 24
Engage time
msec
20
20
20
10
10
30
30
30
Release time
msec
40
40
40
60
60
160
160
160
*Data shown are nominal values at 20°C
Environmental Specifications
Humidity
Ambient Temperature
Vibration
Altitude
www.ge-ip.com
80% non-condensing
0 to 40°C
less than 5G (operating)
3300 feet (1000 m)
GE Intelligent Platforms Control Systems Solutions
5.73
Servo Motors
Motion Control Systems
βHVis Series Servo Motors
Specifications
Motor Model
Unit
β2/4000HVis
β4/4000HVis
β8/3000HVis
Cont Stall Torque*
Nm
2
3.5
in-lb17.7
31
Peak Torque*
Nm
7
10
in-lb62
88.5
5.15
Rotor Inertia
kgm2 x 10-42.91
45.58
in-lb-s2 x 10-425.76
Rated Speed
RPM
4000
3000
No Load Speed
RPM
4000
4000
Encoder Resolution
Counts/Rev
131,072
131,072
Flange Size
mm
90
90
β12/3000HVis
β22/2000HVis
7
11
20
62
97.4 177
15
27
45
132.8 239 398.3
11.7
22.8
52.7
103.55
201.80
466.43
2000
2000
2000
3000
3000
2000
131,072
131,072
131,072
130
130
174
Mechanical Data
Weight
Axial Load Rating
Radial Load Rating
Mechanical Time Constant
Thermal Time Constant
Static Friction kg2.8
lb6.16
kg
8
lb17.6
kg
25
lb55
msec
4
min
15
Nm
0.1
4.3 7.4 11.9 17
9.46 16.28 26.18 37.4
8
20
20
60
17.6 44
44 132
25
70
70
200
55 154 154 440
3
3
2
2
20
20
25
30
0.2
0.3
0.4
0.8
Electrical Data
Torque Constant *
Resistance*
Back EMF Constant*
Rated Motor Power*
Cont. Stall Current
Max Current
Insulation
Nm/A
1.23
1.5
in-lb/A10.89
13.28
ohms6.6
4
V(rms)/krpm
43
53
kW
0.5
0.75
HP0.67
1
A (rms)
1.6
2.3
A (peak)
10
10
Class F
Class F
Class F
2.32
2.16
3.5
20.53
19.12
30.98
3.9
1.6
1.8
81
76
120
1.2
1.8
2.5
1.6
2.4
3.4
3
5.1
5.6
10
20
20
Class F
Class F
Class F
Amplifier Model
Amp Model Number
βSVM1-10HVi
βSVM1-10HVi
βSVM1-10HVi
βSVM1-20HVi
βSVM1-20HVi
Brake Data
Holding Torque
in-lb
26.6
26.6
Nm3
3
0.2
Inertia Adder
kgm2 x 10-40.2
1.770
in-lb-s2 x 10-41.770
Weight Adder
lb
2.2
2.2
kg1
1
Current
A0.9 0.9
Voltage
VDC24
24
Engage time
msec
10
10
Release time
msec
60
60
70.8
8
0.7
6.195
4.84
2.2
1.1
24
30
160
70.8
309.8
8
35
0.7
6
6.195
53.100
4.84
13.2
2.2 6
1.1 1.2
24
24
30
30
160
160
*Data shown are nominal values at 20°C
Environmental Specifications
Humidity
Ambient Temperature
Vibration
Altitude
5.74
80% non-condensing
0 to 40° C
less than 5G (operating)
3300 feet (1000 m)
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Motors
βis and βHVis Series Servo Motors
Speed Torque Curves
The curves illustrate the relationship
between motor speed and output
torque. The motor can operate continuously at any combination of speed and
torque within the prescribed continuous
operating zone. The limit of the continuous operating zone is determined with
the motor’s ambient temperature at 20°C
and its drive current as a pure sine wave.
Actual operation is limited by the current
β0.4/5000is
1.2
5
0.4
2
Intermittent Operation
1.5
1
0.5
0.2
1000
2000
4000
3000
0
5000
1000
2000
Continuous Operation
3000
4000
5000
0
6000
1000
2000
3
12
8
To r q u e ( N m )
To r q u e (N m )
4
6000
14
Intermittent Operation
Intermittent Operation
5000
16
10
6
4000
β8/3000is and β8/3000HVis
12
7
3000
Speed (RPM)
β4/4000is and β4/4000HVis
β2/4000is and β2/4000HVis
Torque (Nm )
2
Speed (RPM)
8
6
4
10
Intermittent Operation
8
6
4
2
0
Intermittent Operation
3
1
Speed (RPM)
1
4
Continuous Operation
Continuous Operation
5
To r q u e ( Nm )
To r q u e ( Nm )
Torque ( Nm)
Intermittent Operation
0.6
β1/6000is
6
2.5
0.8
0
β0.5/6000is
3
1
of the servo drive unit. The continuous
operating zone must be derated for
­ambient temperature above 20°C.
2
Continuous Operation
1000
2000
3000
0
4000
Continuous Operation
2
1000
2000
Speed (RPM)
3000
4000
Speed (RPM)
Continuous Operation
0
1000
2000
3000
Speed (RPM)
β22/2000is and β22/2000HVis
β12/3000is and β12/3000HVis
50
30
45
40
20
To rq u e ( Nm)
Tor que ( Nm)
25
Intermittent Operation
15
10
5
35
25
20
15
10
Continuous Operation
5
0
2000
1000
Speed (RPM)
www.ge-ip.com
3000
Intermittent Operation
30
0
Continuous Operation
500
1000
1500
2000
Speed (RPM)
GE Intelligent Platforms Control Systems Solutions
5.75
Servo Motors
Motion Control Systems
βis Series Servo Motors
Dimensions
β0.4/5000is, β0.5/6000is, β1/6000is
6
38.2
1
4 - ø 5.5
2
15.8
15.8
ON ø 70 D.B.C
14
60
37.7
ø 50 +0
-0.025
80
0.5
37.6
ø
3
45º
3
ø 16.8
C
B
A
Motor
A5
20
(3)
A2
20
A3
0.5
ø 50 +0
-0.025
B04/5_05/5_1/5iseries_MOTOR.eps
A1
A4
3.5
Shaft detail
Dimensions shown mm
Dimension
A
A with brake
A1
β0.4/5000is
β0.5/6000is
β1/6000is
ConnectorDescription
75 89.5118.5
101.5
116
145
B04/4_05/5_1/5iseries_SHAFT.eps
0
0
ø9 -0.009
ø9 -0.009
A21.2 -0.1 0
1.2 -0.1 0
0
ø14 -0.011
1
Brake (optional)
2Power
3
Encoder
0
2 -0.1
0
0
0
A33 -0.025
3 -0.025
5 -0.33
A4
M3 Depth 6
M3 Depth 6
M4 Depth 10
A5
2525 30
B
65 79.5108.5
B with brake
91.5
106
135
C
34.549 78
C with brake
61
75.5
104.5
Notes
1. Shaft diameter runout = 0.02 mm max
2. Flange surface runout = 0.06 mm max
3. Maximum radial load for output shaft is 20 kgf (44 lb)
5.76
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Motors
βis Series Servo Motors
Dimensions
β2/4000is, β2/4000HVis
32
4 - ø 6.6 ON ø 100 D.B.C
ø 43
ø 80 +0
-0.03
12
+0.5
-0.5
22
75
10
40
20
3
66.2
56.7
ø1
7
8.7
4
D
21.4
30.6
C
Power Connections
B
90
A
Motor
23
18
4
G
5
6
12
1
2
3
4
5
6
U
V
W
G
B
B
+0.012
11
M5 Depth 12
Shaft detail
Dimension
8
3
W
ø 14 +0.001
16
11.2
+0
10 -0.009
+0
3 -0.025
2
V
Power/Brake Connections
+0
-0.030
5
B2/4_iseries_MOTOR.eps
1
U
Dimensions shown mm
β2/4000is
β2/4000HVis
A130
A with brake
159
B119
B with brake
148
C75
C with brake
75
D59
D with brake
59
B2/4_4/4iseries_SHAFT.eps
Notes
1. Shaft diameter runout = 0.02 mm max
2. Flange surface runout = 0.06 mm max
3. Maximum radial load for output shaft is 25 kgf (55 lb)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.77
Servo Motors
Motion Control Systems
βis Series Servo Motors
Dimensions
β4/4000is, β4/4000HVis
30
4 - ø 6.6 ON ø 100 D.B.C
ø 43
ø 80 +0
-0.03
22
75
14
40
20
3
66.2
56.7
ø1
7
8.7
4
D
21.4
30.6
C
Power Connections
B
90
A
Motor
23
5
2
3
4
V
W
G
5
6
Power/Brake Connections
+0
-0.030
B4/4_iseries_MOTOR.eps
12
1
2
3
4
5
6
U
V
W
G
B
B
11
16
+0.012
ø 14 +0.001
8
1
U
M5 Depth 12
Shaft detail
Dimensions shown mm
Dimension
β4/4000is
β4/4000HVis
A166
A with brake
195
B155
B with brake
184
B2/4_4/4iseries_SHAFT.eps
C111
C with brake
111
D95
D with brake
95
Notes
1. Shaft diameter runout = 0.02 mm max
2. Flange surface runout = 0.06 mm max
3. Maximum radial load for output shaft is 25 kgf (55 lb)
5.78
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Motors
βis Series Servo Motors
Dimensions
β8/3000is, β8/3000HVis,
β12/3000is, β12/3000HVis
55
4- ø 9 ON ø 145 D.B.C.
45º
4
31
6
22
52
75
35
130
22
1
20
(8.7)
(8.7)
25
10
40
3
72
65
ø 74
+0
ø 110 -0.035
ø1
39.5
+0
5 -0.030
2
47
B
Motor
A
A1
+0
6 -0.03
2 - M4 DEPTH 10
+0
3 -0.29
8 -0.036
+0
2.5 -0.13
+0
M8 DEPTH 16
B8/3_12/3iseries_MOTOR.eps
10
+0
+0
ø 19 -0.013
ø 24 -0.021
Shaft detail
β8/3000is
β8/3000HVis
β12/3000is
β12/3000HVis
Dimension
A
A with brake
A1
B
B with brake
Dimensions shown mm
β8/3000is
β8/3000HVis
β12/3000is
β12/3000HVis
166222
191
247
3645
108164
133
189
ConnectorDescription
B8/3_12/3iseries_SHAFT.eps
1
Brake (optional)
2Power
3
Encoder
Notes
1. Shaft diameter runout = 0.02 mm max
2. Flange surface runout = 0.05 mm max
3. Maximum radial load for output shaft is 70 kgf (154 lb)
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.79
Servo Motors
Motion Control Systems
βis Servo Series Motors
Dimensions
β22/2000is, β22/2000HVis
4- ø 13.5 ON ø 200 D.B.C.
B
3.2
22 ± 0.5
20
31
51 (4 sides)
79
45º
+0.01
40
25
44
3
38
(8.7)
12
(22)
1
B
174
Motor
(8.7)
0
105
23
94
ø
22
ø 35 -0
+0
ø 114.3 -0.025
80
2
50
A
+0
10 -0.038
+0
-0.30
70
3
2 - M6 DEPTH 10
B22/2iseries_MOTOR.eps
20
Shaft detail
Dimensions shown mm
Dimension
β22/2000is
β22/2000HVis
A202
A with brake
243
B141
B with brake
182
ConnectorDescription
B22/2iseries_SHAFT.eps
1
Brake (optional)
2Power
3
Encoder
Notes
1. Shaft diameter runout = 0.03 mm max
2. Flange surface runout = 0.06 mm max
3. Maximum radial load for output shaft is 200 kgf (440 lb)
5.80
GE Intelligent Platforms Control Systems Solutions
www.ge-ip.com
Motion Control Systems
Servo Motors
βis and βHVis Series Servo Motors
Connections
Description
Serial Encoder Connections
1
2
4
5
3
6
8
9
7
10
3
2
12
5
7
9
4
6
8
10
14
16
18
20
βi Series Amplifier
JF1 Connector
N/C
21
N/C
12
RD
65
RD
All βis and βHVis Motors
1
βis and βHVis Motors
56
+5 VDC
8, 9
9, 20
0 VDC
7, 10
12, 14
+6 VA (battery)
4
7
Frame Ground
3
16
Cable Shield
3
16
GE Mating Motor Connector:
ZA06B-6114-K204#E (90 degree)
ZA06B-6114-K204#S (Straight)
βi and βHVis Amplifier (JF1)
Power and Brake Connections
6 5 4 3 2 1
β2is and β4is Motor Power/Brake
β2HVis and β4HVis Motor Power/Brake
D
A
C
B
β8is, β12is and β22is Motor Power
β8HVis, β12HVis and β22HVis Motor Power
2
3
β0.4is, β0.5is and β1is Motor Power
1
3
4
β8is, β12is and β22is Brake
β8HVis, β12HVis and β22HVis Brake
2
3
Phase U
1
1
A
Phase V
2
2
B
V
Phase W
3
3
C
W
Earth (case)
4
4
D
PE
Brake VDC
n/a
5
n/a
n/a
Brake VDC
U
n/a
6
n/a
n/a
GE Mating Motor Connector:
Amplifier Mating Connector:
ZA06B-6114-K220#E (90 degree) (β2is, β4is, β2HVis, β4HVis) ZA06B-6130-K200 (β0.4 to β8is)
ZA06B-6114-K220#S (Straight) (β2is, β4is, β2HVis, β4HVis) ZA06B-6110-K202#YYS (β12is, β22is,
Z44A730464-G18 (90 degree) (β8is, β12is, β8HVis, β12HVis)All βHVis)
Z44A730464-G17 (Straight) (β2is, β4is, β2HVis, β4HVis)
ZA06B-6114-K230#E (β0.4is, β0.5is, β1is)
Z44A730464-G20 (90 degree) (β22is, β22HVis)
Z44A730464-G19 (Straight) (β22is, β22HVis)
Description
1
4
2
β2is & β4is β8is, β12is, & β22is
βi -Series Amplifier
β2HVis & β4HVis β8HVis, β12HVis, & β22HVis CZ7/CZ5 Connector
β0.4is, β0.5is & β1is
Description
Motor Connector
Motor Connector
Motor Connector
β0.4is, β0.5is & β1is Motor Brake Connector
β8is, β12is, & β22is
β8HVis, β12HVis, & β22HVis
Motor Brake Connector
Brake VDC
1
1
Brake VDC
2
2
Earth (case)
4
4
GE Mating Motor Connector: ZA06B-6114-K213#E (90 degree) (β8is, β12is, β22is, β8HVis, β12HVis, β22HVis)
ZA06B-6114-K213#S (Straight) (β8is, β12is, β22is, β8HVis, β12HVis, β22HVis)
ZA06B-6114-K232#E (β0.4is, β0.5is, β1is)
24 VDC Brake power connections are not polarized.
1
4
β0.4is, β0.5is and β1is Brake
www.ge-ip.com
GE Intelligent Platforms Control Systems Solutions
5.81
Servo Motors
Motion Control Systems
βis Series Servo Motors
βHVis Series Servo Motors
Ordering Information
Ordering Information
Model Number
Description
Model Number
Description
ZA06B-0114-B203
ZA06B-0114-B203#0100
ZA06B-0114-B503
ZA06B-0114-B503#0100
ZA06B-0115-B203
ZA06B-0115-B203#0100
ZA06B-0115-B503
ZA06B-0115-B503#0100
ZA06B-0116-B203
ZA06B-0116-B203#0100
ZA06B-0116-B503
ZA06B-0116-B503#0100
ZA06B-0061-B203
ZA06B-0061-B203#0100
ZA06B-0061-B503
ZA06B-0061-B503#0100
ZA06B-0063-B203
ZA06B-0063-B203#0100
ZA06B-0063-B503
ZA06B-0063-B503#0100
ZA06B-0075-B203
ZA06B-0075-B203#0100
ZA06B-0075-B503
ZA06B-0075-B503#0100
ZA06B-0078-B203
ZA06B-0078-B203#0100
ZA06B-0078-B503
ZA06B-0078-B503#0100
ZA06B-0085-B203
ZA06B-0085-B203#0100
ZA06B-0085-B503
ZA06B-0085-B503#0100
β0.4/5000is Servo Motor
β0.4/5000is Servo Motor, IP67 Protection
β0.4/5000is Servo Motor with Brake
β0.4/5000is Servo Motor with Brake, IP67 Protection
β0.5/6000is Servo Motor
β0.5/6000is Servo Motor, IP67 Protection
β0.5/6000is Servo Motor with Brake
β0.5/6000is Servo Motor with Brake, IP67 Protection
β1/6000is Servo Motor
β1/6000is Servo Motor, IP67 Protection
β1/6000is Servo Motor with Brake
β1/6000is Servo Motor with Brake, IP67 Protection
β2/4000is Servo Motor
β2/4000is Servo Motor, IP67 Protection
β2/4000is Servo Motor with Brake
β2/4000is Servo Motor with Brake, IP67 Protection
β4/4000is Servo Motor
β4/4000is Servo Motor, IP67 Protection
β4/4000is Servo Motor with Brake
β4/4000is Servo Motor with Brake, IP67 Protection
β8/3000is Servo Motor
β8/3000is Servo Motor, IP67 Protection
β8/3000is Servo Motor with Brake
β8/3000is Servo Motor with Brake, IP67 Protection
β12/3000is Servo Motor
β12/3000is Servo Motor, IP67 Protection
β12/3000is Servo Motor with Brake
β12/3000is Servo Motor with Brake, IP67 Protection
β22/2000is Servo Motor
β22/2000is Servo Motor, IP67 Protection
β22/2000is Servo Motor with Brake
β22/2000is Servo Motor with Brake, IP67 Protection
ZA06B-0062-B203
ZA06B-0062-B203#0100
ZA06B-0062-B503
ZA06B-0062-B503#0100
ZA06B-0064-B203
ZA06B-0064-B203#0100
ZA06B-0064-B503
ZA06B-0064-B503#0100
ZA06B-0076-B203
ZA06B-0076-B203#0100
ZA06B-0076-B503
ZA06B-0076-B503#0100
ZA06B-0079-B203
ZA06B-0079-B203#0100
ZA06B-0079-B503
ZA06B-0079-B503#0100
ZA06B-0086-B203
ZA06B-0086-B203#0100
ZA06B-0086-B503
ZA06B-0086-B503#0100
β2/4000HVis Servo Motor
β2/4000HVis Servo Motor, IP67 Protection
β2/4000HVis Servo Motor with Brake
β2/4000HVis Servo Motor with Brake, IP67 Protection
β4/4000HVis Servo Motor
β4/4000HVis Servo Motor, IP67 Protection
β4/4000HVis Servo Motor with Brake
β4/4000HVis Servo Motor with Brake, IP67 Protection
β8/3000HVis Servo Motor
β8/3000HVis Servo Motor, IP67 Protection
β8/3000HVis Servo Motor with Brake
β8/3000HVis Servo Motor with Brake, IP67 Protection
β12/3000HVis Servo Motor
β12/3000HVis Servo Motor, IP67 Protection
β12/3000HVis Servo Motor with Brake
β12/3000HVis Servo Motor with Brake, IP67 Protection
β22/2000HVis Servo Motor
β22/2000HVis Servo Motor, IP67 Protection
β22/2000HVis Servo Motor with Brake
β22/2000HVis Servo Motor with Brake, IP67 Protection
5.82
GE Intelligent Platforms Control Systems Solutions
Motor Cables
See applicable amplifier section for information about the proper
cables to use with each motor.
www.ge-ip.com
Motion Control Systems
Motion Software
Servo Motor Sizing Software
The GE Sizer is a powerful motor selection program to assist in the selection of GE servo solutions for a broad range of user defined
applications. GE Sizer is one of the most advanced motor selection programs available, providing users the flexibility to quickly define
and analyze many possible system configurations in order to determine the optimum solution. Advanced features include:
• Graphical design of system mechanics and motion profiles
• Multiple axes can be analyzed and saved in one file with user defined
axes names
• Flexible user defined units of measure
• Inclined loads in increments of 1 degree with user defined ­counterbalancing
• Graphical display of selected motor torque/speed curve with
superimposed loading
• Comprehensive on-line and printed report can be exported to an MS-Word
template that can be customized by the user
The Axis Design screen (above) is first used to define the system mechanics
using graphical icons with fill-in-the-blank data tables.
• Qui