Quick Start Guide

 1 TZ400 / TZ400 W front and rear panels
SonicWall™ TZ400 / TZ400 Wireless Check package contents
Verify that your package has the following contents:
• SonicWall appliance
Wireless (W0) LED
Front Panel
2 (TZ 400 W only) Indicates
802.11 b/g/n/ac security
status
USB / SSD port
Ethernet Port Status (X0-X6)
External USB and SSD hard
drive support
Top - Provides 10/100 Mbps Ethernet port status
Bottom - Provides 1 Gbps Ethernet port status
• Antennas (3) (TZ400 Wireless appliance only)
1000
SonicWall TZ400 W
W0
U0
X1
X2
X3
X4
X5
X6
10/100/act
/ act
on on
/ act
1000/act
ss
wlan
lan
wan
Test LED
Fast blinking - Initializing
Slow blinking - SafeMode
Antenna Screws (3)
Center Antenna Screw
(TZ 400 W only) Provides 802.11 wireless capabilities
to the SonicWall appliance
• Standard power cord
• Quick Start Guide
(TZ 400 W only) Indicates 802.11
b/g/n/ac activity
For future use
Indicates Power Supply status
Rear Panel
• Connect the antennas to the appliance. Note that the center antenna is labeled and is only compatible with the center antenna screw. (TZ400 Wireless appliance only)
Wireless LAN LED
Service LED
Power LED
X0
security
security
Power on
• Connect the power adaptor to the appliance and to the power cable. Plug the power cable into an appropriate outlet (100‐240 volts AC). • Ethernet cable • Standard power adaptor
Quick Start Guide
3 NOTE: The included power cord is approved for use only in specific countries or regions. Before using a power cord, verify that it is rated and approved for use in your location.
(TZ 400 W only) The center antenna screw is only
compatible with the enclosed center antenna
120V AC
(U.S.)
• The TZ appliance powers on and the Test LED blinks during the boot sequence. 1000
SonicWall TZ400 W
U0
W0
X0
X1
wlan
lan
wan
X3
X4
X5
X6
1000/act
ss
wan
X2
10/100/act
power
lan
1000
SonicWall TZ400 W
console
X6
X5
X4
X3
X2
X1
ss
Regulatory Model Numbers: Access the SonicOS Command
Line Interface (CLI) using a
compatible CLI cable
APL28‐0B5 TZ400 W
Copyright © 2017 SonicWall Inc. All rights reserved.
SonicWall is a trademark or registered trademark of SonicWall Inc. and/or its affiliates in the U.S.A. and/or other countries. All other trademarks and registered trademarks are property of their respective owners.
4 W0
X0
X1
wlan
lan
wan
X2
X3
X4
X5
X6
10/100/act
security
1000/act
Power Supply
Console Port
APL28‐0B4 TZ400 U0
on / act
X0
X1 Port
X2 - X4 Ports
For WAN access
Configurable ports
Provides power to
the SonicWall
appliance
X0 Port
Reset Button
For LAN access
Press and hold for several
seconds to set the appliance
into Safe Mode
Connect the interfaces
CAUTION: Only use the included power adapter with this appliance. Do not use a power adapter that is damaged or from another appliance.
• Click on the link in “To launch the SonicWall Setup Wizard, click here.” • The automatic WAN IP settings are displayed. Click Next.
• Connect the WAN interface (X1) to your Internet connection using a standard Ethernet cable.
The information in this document is provided in connection with SonicWall Inc. and/or its affiliates' products. No license, express or implied, by estoppel or otherwise, to any intellectual property right is granted by this document or in connection with the sale of SonicWall products. EXCEPT AS SET FORTH IN THE TERMS AND CONDITIONS AS SPECIFIED IN THE LICENSE AGREEMENT FOR THIS PRODUCT, SONICWALL AND/OR ITS AFFILIATES ASSUME NO LIABILITY WHATSOEVER AND DISCLAIMS ANY EXPRESS, IMPLIED OR STATUTORY WARRANTY RELATING TO ITS PRODUCTS INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON‐ INFRINGEMENT. IN NO EVENT SHALL SONICWALL AND/OR ITS AFFILIATES BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL OR INCIDENTAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTERRUPTION OR LOSS OF INFORMATION) ARISING OUT OF THE USE OR INABILITY TO USE THIS DOCUMENT, EVEN IF SONICWALL AND/OR ITS AFFILIATES HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SonicWall and/or its affiliates make no representations or warranties with respect to the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications and product descriptions at any time without notice. SonicWall Inc. and/or its affiliates do not make any commitment to update the information contained in this document.
• Connect the LAN interface (X0) to your computer using a standard Ethernet cable.
• The SonicOS Startup Guide opens. Internet
wan
lan
X1
X0
For more information, visit https://www.sonicwall.com/legal/.
Legend
NOTE: For manual configuration, refer to the latest SonicOS Administration Guide.
WARNING: A WARNING icon indicates a potential for property damage, personal injury, or death.
CAUTION: A CAUTION icon indicates potential damage to hardware or loss of data if instructions are not followed.
IMPORTANT, NOTE, TIP, MOBILE, or VIDEO: An information icon indicates supporting information.
5 • The new IP Configuration is displayed. Click Done. Run the Setup Wizard
Configuring Wireless LAN settings
• Navigate to https://192.168.168.168 on your Web browser.
http://192.168.168.168/
http://192.168.168.168/
TZ400 / TZ400 Wireless Quick Start Guide
Updated ‐ February 2017
232‐003783‐50 Rev B
• Click Next and follow the prompts in the Startup Guide pages that follow. • Enter the TZ appliance administrator credentials to change the password, if you wish. Click Next.
NOTE: The default administrator credentials are Username: admin Password: password
TIP: Your computer should be using DHCP IP addressing.
• Log in to your TZ appliance and click the Wizards icon. • Select the radio button for the Wireless Guide wizard.
6 Register product
• Point your browser to the appliance LAN IP address (default https://192.168.168.168) and log in using the administrator credentials. • Log in using your MySonicWall account name and password. If you do not have a MySonicWall account, click the Create MySonicWall account link to create an account.
7 Get the latest firmware
• In a Web browser, navigate to http://www.mysonicwall.com • Click Downloads and select TZ400 or TZ400 W Firmware from the Software Type menu.
• Click Register on the System > Status page under Security Services.
• Click the link for the firmware you want and save the file to a location on your computer. • On the TZ appliance, navigate to the System > Settings page. Click the Upload New Firmware button. • Click the Browse button to navigate to and select the firmware you just downloaded. • Click Next and follow the prompts in the Wireless Guide wizard. For more information and complete procedures, refer to the latest SonicOS Administration Guide. For international (non USA or Japan) TZ Wireless appliances, you are asked to select a country code when using the Wireless Guide or when you initially navigate to the Wireless > Settings page. Be sure to select the country code for the country in which the appliance will be deployed, even if you are not currently in that country. TIP: Registering the appliance from SonicOS requires that DNS Server settings are configured on the WAN (X1) interface.
IMPORTANT: If you select the country code for Canada, it cannot be changed except by contacting SonicWall Support.
8 Mounting the TZ appliance
WARNING: Do not mount the appliance on the ceiling, it is not designed for secure ceiling mounting.
For optional wall mounting, you need:
• Screwdriver
• Drill with appropriate size bit
• For mounting on drywall: • Click Upload and wait for the upload to complete.
NOTE: Your appliance must be registered to download the latest firmware.
9 Safety and regulatory information
WARNING: For your safety, follow all instructions listed in this section.
Installing the appliance
Install in a location away from direct sunlight and sources of heat. A maximum ambient temperature of 104º F (40º C) is recommended.
Route cables away from power lines, fluorescent lighting fixtures, and sources of noise such as radios, transmitters, and broadband amplifiers.
The included power cord(s) are approved for use only in specific countries or regions. Before using a power cord, verify that it is rated and approved for use in your location. • Two #6 pan‐head screws, 1 inch long (7mm diameter head, 25mm long)
Ensure that no water or excessive moisture can enter the unit.
• Two wall anchors
Consideration must be given to the connection of the equipment to the supply circuit. Appropriate consideration of equipment nameplate ratings must be used when addressing this concern. Do not overload the circuit.
• For mounting on solid wood or metal: • Two #6 pan‐head wood or machine screws, 1 inch long (7mm diameter head, 25mm long)
Allow unrestricted airflow around the unit and through the vents on the side of the unit. A minimum of 1 inch (25.44mm) clearance is recommended.
This equipment is not intended for use at workplaces with visual display units, in accordance with §2 of the German ordinance for workplaces with visual display units. To avoid incommoding reflections at visual display workplaces this device must not be placed in the direct field of view.
To mount the appliance on the wall:
Lithium battery warning
1 Drill two holes 4.5 inches (11.5 cm) apart in the wall where you want to mount the appliance. The Lithium Battery used in the SonicWall security appliance may not be replaced by the user. Return the SonicWall security appliance to a SonicWall‐authorized service center for replacement with the same or equivalent type recommended by the manufacturer. If, for any reason, the battery or SonicWall security appliance must be disposed of, do so following the battery manufacturer's instructions.
2 If using wall anchors, insert a wall anchor into each hole.
3 Insert a screw into each wall anchor (into each hole if not using wall anchors), leaving 3/16 inches (0.45 cm) of the screws exposed (including screw head).
4 Position the appliance mounting slots over the screws and press in and down until the appliance is securely mounted.
• MySonicWall directly obtains the necessary information from the TZ appliance. When finished, you will see a message that registration has been completed. Click Continue.
EU and EFTA
This device is approved for use in EU member states and EFTA countries as shown on the appliance label.
TZ400 W (RM: APL28‐0B5) RF Transmitter Bands and Power
Frequency Band
Maximum Radio‐Frequency Power Transmitted
MHz
dBm EIRP
2412 ‐ 2472
19.06
5180 ‐ 5240
22.19
5260 ‐ 5320
22.07
5500 ‐ 5700
26.29
Declaration of conformity A “Declaration of Conformity” in accordance with the directives and standards has been made and is on file at SonicWall International Limited, City Gate Park, Mahon, Cork, Ireland.
CE declarations can be found online at https://support.sonicwall.com.
NOTE: Additional regulatory notifications and information for this product can be found online at https://support.sonicwall.com. All Ethernet and RS232 (Console) cables are designed for intra‐building connection to other equipment. Do not connect these ports directly to communication wiring or other wiring that exits the building where the SonicWall appliance is located. Power supply information If the power supply is missing from your SonicWall product package, please contact SonicWall Technical Support at https://support.sonicwall.com/contact‐support for a replacement. This product should only be used with a UL listed power supply marked “I.T.E. LPS” with an output rated 12V DC, minimum 2.0 A, Tma: minimum 40 degree C.
für die Verwendung in bestimmten Ländern und Regionen zugelassen. Überprüfen Sie bitte vor der Verwendung eins Netzkabels, ob es für die Verwendung in Ihrem Land oder Ihrer Region zugelassen ist und den geforderten Normen entspricht.
Stellen Sie sicher, dass das Gerät vor Wasser und hoher Luftfeuchtigkeit geschützt ist.
Stellen Sie sicher, dass die Luft um das Gerät herum zirkulieren kann und die Lüftungsschlitze an der Seite des Gehäuses frei sind. Hier ist ein Belüftungsabstand von mindestens 26 mm einzuhalten.
Prüfen Sie den Anschluss des Geräts an die Stromversorgung, damit der Überstromschutz sowie die elektrische Leitung nicht von einer eventuellen Überlastung der Stromversorgung beeinflusst werden. Prüfen Sie dabei sorgfältig die Angaben auf dem Aufkleber des Geräts. Überlasten Sie nicht den Stromkreis.
Dieses Gerät ist nicht zur Verwendung an Arbeitsplätzen mit visuellen Anzeigegeräten gemäß § 2 der deutschen Verordnung für Arbeitsplätze mit visuellen Anzeigegeräten vorgesehen. Um störende Reflexionen am Bildshirmarbeitsplatz zu vermeiden, darf dieses Produkt nicht im unmittelbaren Gesichtsfeld platziert verden.
Verwarnung hinweis zur lithiumbatterie
Die in der Internet Security Appliance von SonicWall verwendete Lithiumbatterie darf nicht vom Benutzer ausgetauscht werden. Zum Austauschen der Batterie muss die SonicWall in ein von SonicWall autorisiertes Service‐Center gebracht werden. Dort wird die Batterie durch denselben oder entsprechenden, vom Hersteller empfohlenen Batterietyp ersetzt. Beachten Sie bei einer Entsorgung der Batterie oder der SonicWall Internet Security Appliance die diesbezüglichen Anweisungen des Herstellers.
Verwarnung kabelverbindungen
台灣 RoHS
限用物質含有情況標示資訊請參考下列網址 : https://support.sonicwall.com. 操作說明 : 輸入產品型號並搜尋
選擇 Technical Documentation
選擇 Safety and Regulatory Reference Guide
Cable connections
• In the Firmware Management Table, click the Boot icon for your new firmware.
Download this document 下載此文件
Verwarnung Weitere hinweise zur montage
Wählen Sie für die Montage einen Ort, der keinem direkten Sonnenlicht ausgesetzt ist und sich nicht in der Nähe von Wärmequellen befindet. Die Umgebungstemperatur darf nicht mehr als 40 °C betragen.
Führen Sie die Kabel nicht entlang von Stromleitungen, Leuchtstoffröhren und Störquellen wie Funksendern oder Breitbandverstärkern.
Das im Lieferumfang enthaltene bzw. die im Lieferumfang enthaltenen Netzkabel sind nur Alle Ethernet‐ und RS232‐C‐Kabel eignen sich für die Verbindung von Geräten in Innenräumen. Schließen Sie an die Anschlüsse der SonicWall keine Kabel an, die aus dem Gebäude herausgeführt werden, in dem sich das Gerät befindet.
Informationen zur stromversorgung Wenn die Stromversorgung von der SonicWall‐Produktpaket fehlt, wenden SonicWall den Technischen Support unter https://support.sonicwall.com/contact‐support.
Dieses Produkt sollte nur mit einem für den Europäischen Markt genehmigten Netzteil mit dem Logo "I.T.E. LPS" und einer Ausgangsleistung von12 VDC, mind. 2.0 A, Tma: mind. 40 Grad C, betrieben werden.
Download PDF