Size: D (LR20)
PLUS POWER
34.2 mm
32.3
9.5 mm
MAX
Zn/MnO2
MN1300
Alkaline-Manganese Dioxide Battery
1.5 mm
MIN.
Nominal Voltage:
1.5 V
Operating Voltage
1.6 - 0.75V
Impedance:
136 m-ohm @ 1kHz
Typical Weight:
139 gm (4.9 oz.)
Typical Volume:
56.4 cm 3 (3.4 in.3 )
Terminals:
Storage Temperature
Range:
Flat
o
o
-20 C to 35 C
Operating Temperature
Range:
o
o
-20 C to 54 C
o
o
(-4 F to 130 F)
ANSI:
IEC:
13A
LR20
(+)
61.5 mm
59.5
(–)
Dimensions shown are IEC/ANSI standards
TYPICAL DISCHARGE CHARACTERISTICS AT 21 ° C (70 ° F)
1.6
1.5
2.2 OHMS
3.9 OHMS
1.4
5.1 OHMS
Voltage
1.3
10 OHMS
1.2
1.1
1
Berkshire Corporate Park
Bethel, CT 06801 U.S.A.
Telephone: Toll-free 1-800-544-5454
Internet: www.duracell.com
0.9
0.8
0
20
40
60
80
100
120
140
160
Service Hours
* Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
6/08
Size: D (LR20)
PLUS POWER
Alkaline-Manganese Dioxide Battery
TYPICAL CONSTANT POWER DISCHARGE
CHARACTERISTICS AT 21°C (70°F)
TYPICAL CONSTANT CURRENT DISCHARGE
CHARACTERISTICS AT 21°C (70°F)
100
1.1 V
30
1.1 V
1.0 V
1.0 V
0.9 V
Service Hours
Service Hours
Zn/MnO2
MN1300
10
10
0.9 V
1
1
0.5
0.5
0.25
0.5
2
1
Discharge Power (Watts)
1
Discharge Current (Amps)
2
TYPICAL DISCHARGE CHARACTERISTICS
AT 21°C (70°F)
16
TYPICAL DISCHARGE CHARACTERISTICS
AT 21°C (70°F)
1.1 V
14
1.0 V
12
0.9 V
1.5
2.00 A
1.4
1.5 A
Amp Hours
10
1.3
1.0 A
Voltage
8
6
4
1.2
0.75 A
1.1
1
2
0.9
0.8
0
2
4
6
8
10
Service Hours
12
14
16
TYPICAL FLASHLIGHT TEST
AT 21°C AND 0°C
1.6
Voltage
2
1
Discharge Current (Amps)
0.25
1.5
0C
1.4
RT
1.3
1.2
1.1
1
0.9
0.8
0
5
10
Service Hours
15
20
Berkshire Corporate Park
Bethel, CT 06801 U.S.A.
Telephone: Toll-free 1-800-544-5454
Internet: www.duracell.com
* Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
6/08
18