Action Instruments™ DIN Rail Mount Signal Conditioners, Isolators

Action Instruments™ DIN Rail Mount Signal Conditioners,
Isolators, Alarms, and Power Supplies
• Wide Ranging and Field Configurable
for Maximum Flexibility
• ASIC Based Design for Maximum Reliability
• Lifetime Warranty
• High Density DIN Rail Mount Saves Panel Space
Ultra SlimPak
Ultra SlimPak offers a wide selection of functions, input
types and ranges. These modules accept most
process signals and output the commonly
required voltages, current, and alarm trips.
SPECIFICATIONS
Isolation:
Humidity:
Temperature Range
Operating:
Storage:
Power
Consumption:
Range:
Alarm Relays:
EG12:
Agency Approvals:
0 to 55°C
-25 to 70°C
1.5W typical, 2.5W Max.
9 to 30 VDC
5A @ 120 VAC or 28 VDC
2A @ 240 VAC
SIGNAL
CONDITIONERS
Housing:
EG8:
1800 VDC between input, output, and power
15 to 95% (@45°C) Operating
0.5"W x 3.54"H x 4.34"D, including rail
(12.6 x 90 x 110.2mm)
0.7"W x 3.54"H x 4.34"D, including rail
(17.7 x 90 x 110.2mm)
CSA per C22.2, UL per UL508, CE
SPECIFICATIONS AND ORDERING INFORMATION
Cat #
G408
Function
Isolator
G108
Limit Alarm
G418
Isolator
G118
Limit Alarm
G428
Isolator
G438
Isolator
Input Span (Field Configurable)
10 mV to 100V
DC Volt
1 mA to 100 mA
DC Current
10 mV to 200V
1 mA to 100 mA
Bipolar switch for ±100% span
Platinum RTD
RTD
25°C to 800°C
Copper RTD
25°C to 468°C
B: 500°C to 1820°C
E: -150°C to 1000°C
Thermocouple J: -200°C to 750°C
K: -200°C to 1370°C
R/S: 50°C to 1760°C
T: -150°C to 400°C
Pot
100 ohms to 100k ohms
G448*
Isolator
Strain Gauge
G468
Isolator
G168
Limit Alarm
G128
Limit Alarm
Input
AC Voltage
AC Current
G478
Isolator
Frequency
WV905
Power Supply AC Power
*Requires 18-30VDC power supply
0.5 mV/V to 50 mV/V
Adjustable Excitation: 1–10 VDC, 120 mA
50 mVAC to 200 VAC
5 mA AC to 5 AAC**
2 Hz to 10 kHz
100 to 240 VAC; 50 to 60 Hz
Housing
EG8
EG12
EG12
Output (Field Configurable)
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 0–20 mA, 4–20 mA)
Alarm (Dual SPDT Relay)
EG12
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 0–20 mA, 4–20 mA)
Alarm (Dual SPDT Relay)
EG12
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 0–20 mA, 4–20 mA)
EG12
Alarm (Dual SPDT Relay)
EG8
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 0–20 mA, 4–20 mA)
EG12
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 0–20 mA, 4–20 mA)
EG8
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 0–20 mA, 4–20 mA)
EG12
Alarm (Dual SPDT Relay)
DC Voltage (0–5V, 0–10V)
EG8
DC Current (0–1 mA, 0–20 mA, 4–20 mA)
17.5mm
24 VDC @ 500 mA
**1 to 5AAC range requires C006 0.1Ω shunt
80
Action Instruments™ IQ Signal Conditioners
• Multi-Channel DC, RTD, T/C Conditioners—Lower Cost/Point
• Ideal for Large Numbers of Data Points
• Extreme Operating Temperature—from -40 to 80°C
• SnapLoc Terminal Blocks
• Optional I/Q Rail Power Bus—Saves Installation Time
• Interlocking Modules—Solid, Reliable Mounting
SPECIFICATIONS
Isolation:
Humidity:
Operating Temperature:
Power:
SIGNAL
CONDITIONERS
HOW TO ORDER—Select the unit with the
output of your choice and then add the code that
identifies the input range to satisfy your application.
Example: Q510-4004 is a 4-channel RTD Input,
2-wire transmitter, with a 0–250°C range and
4–20 mA output.
DC ORDERING INFORMATION
4-20 mA
1-Channel
2-Channel
4-Channel
Q500
-1000
-2000
-4000
DC ORDERING INFORMATION
Input Range
4–20 mA
0–10V
0–5V
1–5V
Q501 (1 Ch)
-1000
-1003
-1004
-1005
Q501 (2 Ch)
-2000
-2003
-2004
-2005
Type J
-0001
-0002
—
—
-0003
—
Type K
-0004
—
-0005
—
—
-0006
Q510
Q488
Q520
Q438
Q448
Input Type
DC Current
DC Current
DC Volts
3-wire RTD Pt100Ω
TC (B, C, E, J, K, N, R, S, T)
Pt RTD (100, 200, 500,
1000), Cu RTD (9),
Ni RTD (120),
90mV, 900mV, 4000Ω
T/C (J,K,T)
Potentiometer
Bridge
81
Range
0–20/4–20 mA
4–20 mA
0–5V, 0–10V,1–5V
See Below
-270 to +1370°C
(type K)
-200 to +850°C
(Pt 100)
See Blow
100Ω to 100kΩ
±5mV to ±200mV
Output
Channels
0–20/4–20 mA 1, 2 or 4
4–20 mA
1 or 2
4–20 mA
0-1mA,
4-20mA,
0–5V,
0-10V
4–20 mA
0-1mA,
4-20mA,
0–5V,
Q478
Frequency
2Hz — 10kHz
0-10V
T/C cold junction compensation (standard). Output linear to mV input.
Type T
-0007
—
—
-0008
—
—
ORDERING INFORMATION—ACCESSORIES
Mounting Hardware
MD02
MD03
IQRL-D002
IQRL-D004
IQRL-D008
Q488
ACTION I/Q SIGNAL CONDITIONERS
Cat #
Q500
Q501
Q520 (T/C) ORDERING INFORMATION
Temp Range
0–500°F
0–1000°F
0–2000°F
0–250°C
0–500°C
0–1000°C
L
Response Time:
Approvals:
From 1800 to 4000 VDC,
input to output and channel to channel
15–90% @ 45°C
40 to 80°C (Q5XX Series)
0 to 55°C (Q4XX Series)
12 to 35 VDC output loop (Q5XX Series)
18 to 30 VDC output common (Q4XX Series)
100 mSec (10–90%) typical
UL508, CSA C22.2, CE
TS32 DIN Rail (2m) Slotted (G-rail)
TS35 x 7.5 DIN Rail (2m) Slotted (H-rail)
IQ Rail for 2 Modules (Q488 only)
IQ Rail for 4 Modules (Q488 only)
IQ Rail for 8 Modules (Q488 only)
Circuit Type
Input Loop Powered
Isolated 2-Wire Transmitter
2 or 4
1
2-Wire Transmitter
Isolated 2-Wire Transmitter
(2, 3 or 4-wire input)
2
1
1
Isolated 2-Wire Transmitter
3-wire to 2-Wire Transmitter
Isolated 4-wire to 2-Wire
Transmitter
Isolated 2-Wire Transmitter
1
Q510 (RTD) ORDERING INFORMATION
Temp Range
0–100°C
0–150°C
0–200°C
0–250°C
0–500°C
0–200°F
0–300°F
0–400°F
0–500°F
0–1000°F
Q510 (2-Ch)
-0001
-0002
-0003
-0004
-0005
-0006
-0007
-0008
-0009
-0010
Q510 (4-Ch)
-4001
-4002
-4003
-4004
-4005
-4006
-4007
-4008
-4009
-4010
Other inputs & AC powered modules also available.
Action Instruments™ Isolating Action Instruments™ DC Input,
Field Configurable Isolator
Two-Wire Transmitter
• Isolated, Linearized Current Loop Output
with Math Functions
for an RTD or Thermocouple Input
• HART Compatible or Field
Configurable with Optional Display
• Intrinsically Safe Operation or with
Display and EP Enclosure
• Programmable for 11 T/C Types,
6 RTD Types, mV or Ohm inputs
• Multi-Function, Multi-Channel Input.
• DC-Frequency or Frequency-DC
Conversion for Totalization/
Integration Applications.
• Math Capability Supports
Many Process Control Functions.
• Switch Selectable or PC Programmable Ranges.
L T79D
The model T798 is a programmable temperature transmitter that
can be factory or field configured using the optional 1 or 2 line
alphanumeric display.
The model T798 is Highway Addressable Remote Transducer
(HART) based, temperature transmitter that can be factory or field
configured using an optional 1 or 2 line alphanumeric display,
optional PC based modem and software. Alternatively an HC275
Hand-Held Communicator loaded with the Action T798 Device
Description from the Hart Foundation Library can be used.
The Q498 can perform single or double input math calculations on
the input values. The available operators are: +, -, *, /, Sq, Sqroot
& Average. Process control functions include Hi/Lo Select, Rate of
Change Limiter and Track & Hold. The frequency input can also
have the math functions applied. A 25-point linearization function
is available for Channel 1 Analog input only. All output math and
process control functions require the C698 software.
SPECIFICATIONS
Linearization:
Thermocouple and RTD linearization to ±0.05°C.
Output:
Analog, two-wire 4-20 mA
Transmitter Accuracy: ±0.05% of the millivolt or ohm equivalent input
reading, or the value from the Accuracy Table,
whichever is greater; plus ±0.05% of the span.
For thermocouples, add ±0.5°C (0.9°F) for
cold junction compensation.
Output
Analog Zero: 100% of Sensor range —Non-interacting
Adjustments:
Analog Full-scale: Normal or Reverse Acting
Operating Temperature: Electronics & Display (with reduced visibility):
-40°C to 85°C, (-40°F to +185°F)
Display (full visibility): -20°C to +70°C,
(-4°F to +158°F)
ORDERING INFORMATION
T797-0000
T797-1000
T798-0000
T798-1000
Displays & Options
T79D-2000
T79D-1000
T79E-1000
T79A-P000
T79A-D000
T79A-M000
T79A-MH00
T79A-C000
Temperature Transmitter, Non IS
Temperature Transmitter, IS-FM/CSA
Temperature Transmitter, Hart, Non IS
Temperature Transmitter, Hart, IS-FM/CSA
Two Line Alphanumeric Display
One line alpha-numeric Display
Weather Proof Head-Mount Enclosure
Pipe Mount Bracket for T79E-0/D only
DIN Rail Mounting Kit
T797 Configuration Modem
T798 Hart Configuration Modem
Configuration Software for T797 & T798
SPECIFICATIONS
Analog Input Ranges
(Two Isolated Channels)
Analog Maximum Overload
(continuous)
Analog Output Ranges
Analog Output Drive
±150mV, ±1.5V, ±15V, ±150V
±2.5mA, ±25mA
200V DC for voltage inputs; 170mA DC and/or
60V DC maximum for current inputs (self-resetting fuse)
0-20mA, 0-10V, ±10V
0-20mA: 12VDC compliance. (600Ω maximum)
Voltage ranges: 10mA drive (1000Ω load minumum)
Analog Output Accuracy
±0.005% of the FS Input Range (±0.05% on 150 volts
range), plus ±0.05% of the FS Output Range
(±0.1% for output loads <200Ω)
Analog Response Time
750msec max. (10-90%)
Analog Input Impedance ≥100kΩ on voltage ranges > 1.5V,
≥10MΩ on voltage ranges <1.5V
70Ω typical (non-overload) on all current ranges
Analog Output Impedance Less than 3Ω on voltage output ranges
≥ 500kΩ on current output ranges
Frequency Input
One channel with two voltage range inputs:
150mV to 50Vrms with 5Vp noise suppression,
or 0.5V to 150Vrms with 20Vp noise suppression,
2Hz to 10kHz in software selectable ranges.
Frequency Output
±0.1%, 2Hz to 10kHz in software selectable ranges
Open collector pulled up through 20k to 18V, with
1mA drive.Sinks up to 20mA from 24V external supply.
Discrete Input
Input active to Common, with soft pull-up (1mA) to +18V
CMR (DC to 60Hz)
≥90dB for 60Hz and 120dB @ DC
Power Requirements
9-30VDC, 2.5 watts max
Isolation
Input to Input to Output to Power, 1800VDC
Size
DIN rail case (0.88" x 4.0" x 4.59")
Operating Temperature
0°C to + 55°C (32 to 131°F)
ORDERING INFORMATION
Q498-0000
C698-0000
H902
H910
H915
DC–Frequency Isolator
Configuration Software & PC Serial Cable
0.2Amp, 24VDC Power Supply
1Amp, 24VDC Power Supply
2.3Amp, 24VDC Power Supply
82
SIGNAL
CONDITIONERS
Both the T798 and T797 accept thermocouple (B, C, E, J, K, L, N,
R, S, T, U & special) and 2, 3, or 4 wire Platinum RTDs (385 or 392
alpha) as well as millivolt (mV) and resistance inputs.
The Q498 is a DC powered, DIN rail mount, DC input signal
conditioner. The unit is fully isolated to 1800V between input,
output and power. Two isolated analog inputs each accept either a
DC voltage or current. One analog output delivers either DC bi-polar
voltage or uni-polar current. The Q498 also has a separated
frequency input channel and a frequency output, as well as a
discrete input and output channel.
NEW
Selco Transmitters
INPUT RANGES
• Miniature Size
Input Type XA - DC Volts/mA
• Variety of Input Types
• 1500V Isolation
• AC or DC Powered
• DIN Rail Mounting
TZ-1XA
SPECIFICATIONS
Basic Accuracy:
Load/supply variation:
Temperature coefficient:
Response time:
Front adjustments:
Insulation resistance:
Dielectric strength:
Power supply:
Operating temperature:
Case material:
Dimensions (mm):
±0.1% of full scale, except
±0.2% of full scale on CA, DA & EA types
±0.06% of full scale each
±0.02% FS/°C
<50ms (0 to 90%) except 500ms on CA type,
700ms on DA & EA types
±5% for zero & span
>100MΩ at 500VDC, between input and
output or power supply
1 min. at 1500VAC, between input and
output or power supply
24VDC ±10%
100-240VAC ±10%
-5 to 50°C, <90% RH (non-condensing)
Black ABS, 94V-2
25 W x 99 H x 41 D
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: TZ-1XA-22L
A
A
B
C
D
E
B
_
C
D
E
Basic Unit
TZ-1
Transmitter, 100-240 VAC powered
TZ-5
Transmitter, 24 VDC powered
Input Type
XA
DC Volts/mA
FA
DC mV/μA
EA
AC Volts (TRMS, AC coupled, 40-1000Hz)
DA
AC Amps (TRMS, CT coupled, 40-1000Hz)
AA
RTD (Pt100, 3-wire, α=385)
CA
Thermocouple (J, K, R, S or T)
BA
Potentiometer
LA
mA loop (TZ-5 only)
Input Range
Select code from input table for type specified above
Output Range
Allowable Load
0
0 to 5 VDC
>2kΩ
1
1 to 5 VDC
2
0 to 10 VDC
>4kΩ for positive output,
3
-10 to +10 VDC
>10kΩ for negative output
4
-2 to +2 VDC
>2kΩ for positive output,
5
-2.5 to +2.5 VDC
>10kΩ for negative output
6
-5 to +5 VDC
7
0 to 4 VDC
>2kΩ
A
4 to 20 mADC
<550Ω
B
0 to 20 mADC
Response Time (XA & FA types only)
L
Normal (50 msec)
H
Fast (1 msec on type XA, 3msec on type FA)
Code
0
1
2
3
4
5
6
7
8
9
A
B
Range
0 to 5 VDC
1 to 5 VDC
0 to 10 VDC
-10 to +10 VDC
0 to 1 VDC
0 to 100 mVDC
0 to 60 mVDC
0 to 20 VDC
-2 to +2 VDC
-5 to +5 VDC
4 to 20 mADC
0 to 20 mADC
Input Resistance
>1MΩ
Maximum Input
-50 to +150%
of full scale
250Ω
Input Type FA - DC mV/ μA
Code
0
1
2
3
4
A
B
C
Range
0 to 5 mVDC
0 to 10 mVDC
0 to 50 mVDC
0 to 60 mVDC
0 to 100 mVDC
0 to 10 μADC
0 to 100 μADC
0 to 200 μADC
Input Resistance
>1MΩ
Maximum Input
-50 to +150%
of full scale
1kΩ
500Ω
Input Type EA - AC Volts
Code
1
2
3
4
5
Range
0 to 35 VAC
0 to 100 VAC
0 to 110 VAC
0 to 200 VAC
0 to 220 VAC
Input Resistance
>200kΩ
>1MΩ
Maximum Input
150%
of full scale
or 300VAC
Input Type DA - AC Amps
Code
1
2
Range
0 to 1 AAC
0 to 5 AAC
Input Resistance
<0.05Ω
Maximum Input
7.5 AAC
Input Type AA - RTD
Code
0
1
2
3
4
Range
-50 to +50 °C
0 to 100 °C
0 to 200 °C
0 to 300 °C
-20 to +80 °C
Input Resistance
Maximum Input
Pt100 (3-wire)
-50% to 150%
of full scale
Input Type CA - Thermocouple
Code
J0
K2
K3
K4
K5
R0
S0
T0
T1
TC
J
K
K
K
K
R
S
T
T
Range
0 to 1000 °C
-50 to +200 °C
0 to 200 °C
-50 to +1200 °C
0 to 1200 °C
0 to 1700 °C
0 to 1700 °C
-50 to +350 °C
0 to 350 °C
Input Res.
>1MΩ
Max. Input
±150%
Input Type BA - Potentiometer
Code
1
Range
0 to 100%
Input Resistance
100Ω to 10kΩ
Input Type LA - mA loop
Code
A
Range
4 to 20 mADC
Input Resistance
250Ω
Custom ranges for any input type are available on special order.
82a
NEW
Laurel DIN Rail Transmitters
• Analog and Pulse Inputs
• Serial & Analog Outputs
• RS-232 or RS-485 Communications
• Dual Relay Outputs
• Input/Digital/Analog/Relay Isolation
• Free Setup Software
The Laureate transmitters provide serial data
conversion and analog retransmit for all popular industrial signals. These modules use
the proven circuitry of the Laurel panel
meters for exceptional accuracy at high
update rates.
LTA
L
All Laureate transmitters are easily configured from a PC using the
graphical Laurel Instrument Setup Software. The isolated analog output can be digitally scaled to any portion of the full range. Dual relay
outputs add alarm and control capability. Programmable modes
include operation above or below setpoint, latching or non-latching,
hysteresis and band deviation.
Each DC transmitter is precalibrated for all DCV & DCA ranges. The
user can change the range without recalibration. On the temperature
transmitter, thermocouple or RTD type is field selectable.
Measurement range can be as wide as the entire span of the sensor
type or as narrow as 15°. Cold junction compensation and open
sensor detection are included.
Standard functions on pulse input models are frequency, rate, period,
A to B interval, up/down total to 999999. The extended model provides additional user-configurable functions.
SPECIFICATIONS
Digital Output:
Protocol:
Baud Rate:
Accuracy:
ACCESSORIES
CBL04 RS-232 cable to PC serial port or USB adpator
CBL02 USB to RS-232 cable adapter
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number
Order Example: LTA200DCV1
A
A
B
C
D
B
C
D
Model
LTA2
Standard analog inputs
LTA4
Extended analog inputs*
LTA6
Standard pulse/frequency input**
LTA8
Extended pulse/frequency input**
Power
0
85-264VAC ±10%, 90-300VDC
1
12-30VAC, 10-48VDC
Setpoint Output
1
Dual isolated solid-state relays
Input Type (LTA2 or LTA4)
DCA4
DCV1
200mV DC
RMV1
DCV2
2V DC
RMV2
DCV3
20V DC
RMV3
DCV4
200V DC
RMV4
DCV5
600V DC
RMV5
DCV6
300V DC
RMV6
DCA1
2mA DC
RMA1
DCA2
20mA DC
RMA2
DCA3
200mA DC
P
P1
SG
SG1
WM
WM1
P385
P392
Process 4-20mA in/out
Process Custom mA scaling
Strain Gage 200mV
Strain Gage Custom
Load Cell 20mV
Load Cell Custom
100Ω Pt RTD α=385
100Ω Pt RTD α=392
J
K
R
S
T
E
N
SIGNAL
CONDITIONERS
RS-232 or RS-485 (2- or 4-wire)
Modbus RTU, Modbus ASCII or Laurel ASCII
300-19200
DCV, mA: ±0.01% of FS ±2 counts
ACV, mA: ±0.15% of FS ±2 counts (10Hz-10kHz)
Strain gage, load cell: ±0.01% of FS ±2 counts
RTD: 0.1°C
Thermocouple: 0.2°C
Update Rate:
50 or 60/sec for analog inputs
Load Cell/Strain Gage: 20, 50, 100, 250, 500mV ranges
Thermocouple:
FS range is maximum for each sensor type
Frequency/Pulse Input: AC, magnetic pickups, pulses from NPN or PNP
transistors, contact closures, digital logic
Channel A Frequency: 0.005Hz to 1MHz
Channel B Frequency: 0.005Hz to 250kHz
Time Base Accuracy: ±2ppm
Signal Level:
12mV min, 250VAC max
Update Rate:
Gate time + 30ms + 1 period (20/sec at 60Hz)
Gate Time:
0.01 to 199.99 sec (selectable)
Curve Fitting:
Square root extraction standard,
Custom curve fitting with LTA8
Quadrature Input:
Differential or single ended
Transitions Monitored: x1, x2 or x4
Transitions/sec:
250k max.
Error Correction:
Zero index (Z-channel)
Analog Output:
4-20mA, 0-20mA, 0-10V
Compliance (mA):
10V (0-500Ω load)
Compliance (V):
2mA (>5kΩ load)
Accuracy:
±0.02% of span (analog inputs)
±0.01% of span (pulse inputs)
Resolution:
16 bits (65536 steps)
Power:
DC or 47-63 Hz
Relay Outputs:
Two SPST-NO (Form A) solid-state relays
130mA@140VAC/180VDC
Excitation Output:
5V@50mA, isolated 50V from signal gnd
(DC, Process & FR
10V@60mA, isolated 50V
inputs, jumper
24V@50mA, isolated 50V [DC & Process inputs]
selectable)
15V@60mA, non-isolated [FR input]
Isolation:
250Vrms power/analog/digital
Temperature:
0-55°C operating
Size:
120 x 101 x 22.5 mm
Mounting:
35mm DIN rail
Connections:
Detachable screw terminal plugs
5A DC
200mV AC Trms
2V AC Trms
20V AC Trms
200V AC Trms
600V AC Trms
300V AC Trms
2mA AC Trms
20mA AC Trms
Type J TC
Type K TC
Type R TC
Type S TC
Type T TC
Type E TC
Type N TC
D
Input Type (LTA6 or LTA8)
FR
Dual channel frequency/pulse**
VF1
4-20mA (process totalizing)
VF2
0-1mA (process totalizing)
VF3
0-10V (process totalizing)
QD
Quadrature***
* LTA4 adds custom curve linearization & rate from successive readings.
** LTA6 scalable for frequency, rate, totalizing, timing. LTA8 adds phase
angle, duty cycle, up/down counting, rate & total simultaneously, custom
linearization, arithmetic functions (A+B, A-B, AxB, A/B, A/B-1).
*** LTA6 scalable for position. LTA8 adds scalable rate.
84
Action Instruments™ Low Profile Signal Conditioners
• Low Power
• Higher Accuracy
• Field Configurable
• E-Mail Alarm Notification
L
SlimPak II
SPECIFICATIONS
SIGNAL
CONDITIONERS
Output:
Accuracy (In/Out):
Isolation:
Operating Temp:
Power:
Alarm:
Size:
Approvals:
0-10V, 0-20mA, 4-20mA
±0.015% rng / ±0.05% rng
1800V AC/DC, In/Out/Power
0 to 60°C, <95% RH
9-30VDC, 1W typ.
2 SPDT, 5A@120VAC
0.5" wide DIN rail case
UL508, CSA C22.2, CE
ORDERING INFORMATION
Model
WV408-2000
Function
DC
Range
±150mV, 1.5/15/150V,
2.5/25mA +reverse
WV418-2000
RTD
2/3/4 wire: Pt100, Cu10
WV428-2000
T/C
J,K,T,R,S,E,B,N,C,B
WV438-2000
Potentiometer
100Ω to 100kΩ
WV448-2000
Bridge
±5/10/20/50/100/200mV
(1-10VDC, 120mA excitation)
WV468-2000
AC
±50/150/500mV,
5/20/50/150/250V,
20/100mA
+reverse (40-400Hz)
WV478-2000
Frequency
0-10kHz (150mV-150V)
WVC16-2000
Communication Up to 32 modules to
Ethernet 10Base-T
C650-2000
Software
Includes serial cable
WV905
Power Supply
24VDC @0.5A
Also available as Limit Alarms with latching relays & reset switch
Pyragon Temperature Transmitter
• T/C Head Mount
• Wide Operating
Temperature Range
• Factory Configured,
Ready to Install
L
2700T
SPECIFICATIONS
Input:
T/C J,K,T,E,R,S,B,N,L,U,W
RTD Pt, Ni, Cu; 2,3 or 4-wire
DC -10 to 70mV, -0.1 to 1.1V
Resistance 390Ω, 2200Ω
Input Accuracy: 0.1°C (Pt100), 1°C (K T/C)
Output:
2-wire, 4-20mA or 20-4mA
Output Accuracy: 0.1% of span
Resolution:
Input 16 bit, Output 12 bit
Supply:
8-35VDC
Operating Temp: -40 to 85°C, <98% RH condensing
Dimensions:
1.73" dia x 1.04" (44x26.3mm)
Isolation:
3.75kV AC
ORDERING INFORMATION
PY/2700T
PY/2750T
Temperature Transmitter (specify input type & range)
2700T with Hart® protocol
NLS Series 8000 Signal Conditioners
L
• Input, Output, Isolation, Power Supply and Special Functions Combined into One Low Cost Modular Unit
• Field-Settable Range and Span and Field Configuration
• Fuse Protected Linear Power
• UL Recognized
8000-1-1
• High Impact, Flame Retardant Polycarbonate Case
The Series 8000 signal conditioners are designed with a modular architecture to allow full input, output,
and special function selectability and interchangeability. They can also be used as isolators, signal amplifiers, and transmitters.
See more information online at weschler.com/nls
85
Action Instruments™ Low Profile Signal Conditioners
• Low Power
• Higher Accuracy
• Field Configurable
• E-Mail Alarm Notification
L
SlimPak II
SPECIFICATIONS
SIGNAL
CONDITIONERS
Output:
Accuracy (In/Out):
Isolation:
Operating Temp:
Power:
Alarm:
Size:
Approvals:
0-10V, 0-20mA, 4-20mA
±0.015% rng / ±0.05% rng
1800V AC/DC, In/Out/Power
0 to 60°C, <95% RH
9-30VDC, 1W typ.
2 SPDT, 5A@120VAC
0.5" wide DIN rail case
UL508, CSA C22.2, CE
ORDERING INFORMATION
Model
WV408-2000
Function
DC
Range
±150mV, 1.5/15/150V,
2.5/25mA +reverse
WV418-2000
RTD
2/3/4 wire: Pt100, Cu10
WV428-2000
T/C
J,K,T,R,S,E,B,N,C,B
WV438-2000
Potentiometer
100Ω to 100kΩ
WV448-2000
Bridge
±5/10/20/50/100/200mV
(1-10VDC, 120mA excitation)
WV468-2000
AC
±50/150/500mV,
5/20/50/150/250V,
20/100mA
+reverse (40-400Hz)
WV478-2000
Frequency
0-10kHz (150mV-150V)
WVC16-2000
Communication Up to 32 modules to
Ethernet 10Base-T
C650-2000
Software
Includes serial cable
WV905
Power Supply
24VDC @0.5A
Also available as Limit Alarms with latching relays & reset switch
Pyragon Temperature Transmitter
• T/C Head Mount
• Wide Operating
Temperature Range
• Factory Configured,
Ready to Install
L
2700T
SPECIFICATIONS
Input:
T/C J,K,T,E,R,S,B,N,L,U,W
RTD Pt, Ni, Cu; 2,3 or 4-wire
DC -10 to 70mV, -0.1 to 1.1V
Resistance 390Ω, 2200Ω
Input Accuracy: 0.1°C (Pt100), 1°C (K T/C)
Output:
2-wire, 4-20mA or 20-4mA
Output Accuracy: 0.1% of span
Resolution:
Input 16 bit, Output 12 bit
Supply:
8-35VDC
Operating Temp: -40 to 85°C, <98% RH condensing
Dimensions:
1.73" dia x 1.04" (44x26.3mm)
Isolation:
3.75kV AC
ORDERING INFORMATION
PY/2700T
PY/2750T
Temperature Transmitter (specify input type & range)
2700T with Hart® protocol
NLS Series 8000 Signal Conditioners
L
• Input, Output, Isolation, Power Supply and Special Functions Combined into One Low Cost Modular Unit
• Field-Settable Range and Span and Field Configuration
• Fuse Protected Linear Power
• UL Recognized
8000-1-1
• High Impact, Flame Retardant Polycarbonate Case
The Series 8000 signal conditioners are designed with a modular architecture to allow full input, output,
and special function selectability and interchangeability. They can also be used as isolators, signal amplifiers, and transmitters.
85
NLS Series 8000 Signal Conditioners
ORDERING INFORMATION
To Order—Insert Number Code for Each Letter to Select Catalog Number.
Order Example: 8000-1-1-01(0-27.2V)-60(4-20mADC)
A – B – C – D – E
A
B
C
Basic and Power—See Base Style Selection Chart
8000-1-1
8–Pin, 120 VAC Power
8000-2-1
11–Pin, 120 VAC Power
8000-3-1
20–Pin, 120 VAC Power
8000-2-2
11–Pin, 240 VAC Power
8000-3-2
20–Pin, 240 VAC Power
8000-1-3
8–Pin, 9–30 VDC Power
8000-2-3
11–Pin, 9–30 VDC Power
8000-3-3
20–Pin, 9–30 VDC Power
Input Code
01
DC: Voltage to 300, Current to 100 mA— Specify Range
02 Potentiometer: Any Value from 0–100Ω to 100 kΩ
03 AC: Voltage to 250 V, Current to 100 mA— Specify Range
04 Thermocouple: non-linearized J, K, T, E, R, S, or B— Specify Type and range.
See special function "43"for Linearization
05 RTD: Pt100Ω (∝00385), Cu10Ω or Ni120Ω—Specify Type and Range
06 DC Millivolts: 0–200 (8 mV min span)—Specify Range
08 LVDT: 50 mV/V to 800 mV/V RMS—Specify Range
09 Strain Gauge: 2 mV/V to 20 mV/V—Specify Range
10
Frequency: 0–50 kHz (50 Hz min span)—Specify Range
11
Ramp/Soak Programmer
12 High Select: up to 4 inputs: 4–20 mA, 1–5V, or 0–10V—Specify Range
13 Low Select: up to 4 inputs: 4–20 mA, 1–5V, or 0–10V—Specify Range
14
Add/Subtract: up to 4 inputs: 4–20 mA, 1–5V, or 0–10V—Specify Range
15 Multiply (A x B)—Specify # of inputs and type
16
Divide (A x B)—Specify # of inputs and type
Output Code
60 DC: 0–12V (100 mV min) or 0–50 mA (1 mA min)—Specify Range
70 Frequency: 5V (TTL), 0–50 kHz (11 pulses/hour min)—Specify Range
71
Frequency: Contact Closure 0–2 Hz (11 pph min)—Specify Range
72 Frequency: 24V pulse 0–50 kHz (11 pph min)—Specify Range
73 Valve Positioner: Pot 100-9.9 kΩ, 10k–100 kΩ;
4–20 mADC, 0–1 VDC or 0–10 VDC—Specify feedback type
80 Single Alarm Setpoint: Single Turn Pot. Screwdriver Adj.
D
E
81
Single Alarm Setpoint: Remote 4–20 mADC
82 Single Alarm Setpoint: Remote 1–5 VDC
83 Single Alarm Setpoint: Remote 0–1 VDC
84 Single Alarm Setpoint: Remote 0–10 VDC
85 Single Alarm Setpoint: Multi-turn Pot., Screwdriver Adj.
86 Single Alarm Setpoint: Plus Top Mounted Knob, 0–100%
87 Single Alarm Setpoint: Remote Pot., 0–100Ω to 100 kΩ
90 Dual Alarm Setpoint: Single Turn Pot. Screwdriver
91
Dual Alarm Setpoint: Remote 4–20 mADC
92 Dual Alarm Setpoint: Remote 1–5 VDC
93 Dual Alarm Setpoint: Remote 0–1 VDC
94 Dual Alarm Setpoint: Remote 0–10 VDC
95 Dual Alarm Setpoint: Multi-turn Pot., Screwdriver Adj.
96 Dual Alarm Setpoint: Plus Top Mounted Knob, 0–100%
97
Dual Alarm Setpoint: Remote Pot., 0–100Ω to 100 kΩ
Special Functions
00 None
40 Square Root
41
Power Term: Nth Power
42 Nth Root: Adjustable root 0.5 to 5
43 Thermocouple Linearization (type/range specified by input code)
44 Curve Fit Linearization: Curve or formula must be provided
45 Ramp Buffer: Delays signal action (adj. 1 sec To 20 min)
46 Peak/Valley Sample Hold: Specify Peak or Valley
48 Rate of Change Processor: (Specify time base, 1 sec etc.)
Options for Alarm Setpoints
00 None
01
Low or Low/Low relay sense (Single or dual alarms)
02 High/High relay sense (Dual alarms)
03 Fail-Safe Operation (Dual alarms)
04 Transmitter Output 0–1V output for process, Setpoint #1
and Setpoint #2 (Setpoint output not avail. with strain gage,
add/subtract, or high/low select
05 Latching relay(s): Jumper selectable for Latch/Non-Latch
07
Voltage Output (24V @ 15 mA) replaces relay contacts
Options for Temperature Inputs
06 Down scale burnout for thermocouple input
08 Differential RTD input: Specify differential range
09 Differential thermocouple input: Specify differential range
BASE STYLE SELECTION CHART
Output Code
Type
60
80, 85, 86
90, 95, 96
73, 81, 82, 83,
70
71
60
70, 71
84, 91, 92, 93
72
72 w/46
94; or 80, 85, 86
Input Code
90,95, 96 w/ 07
01/03/04/06/10
DC, AC, Frequency
8
11
20
8
11
11
20
02
Potentiometer
8
20
20
8
20
20
20
05
RTD
20
20
20
8
20
20
20
09
Strain Gauge
11
20
20
11
11
—
—
08
LVDT
11
20
—
20
20
—
—
15/16
Multiply/Divide
8
20
20
8
20
20
20
12/13/14
High/Low
20
20
20
20
20
—
—
11
Ramp/Soak
20
20
—
—
20
—
—
To determine the number of pins required for the signal conditioner, select input code and output code and read across and down. Make sure to order mounting socket.
ACCESSORIES
Mounting Sockets—Required and Sold Separately
DR011 11–Pin Barrier Terminal Socket for DIN Rail or Flush Mount
DR014 Din Rail—Three Foot Length Metal Channel Track
DR018 8–Pin Barrier Terminal Socket for DIN Rail or Flush Mount
SM004 DIN Rail—Four Foot Length Plastic Channel Track
SM008
SM011
SM020
SX008
8–Pin Barrier Terminal Socket for Channel Track
11–Pin Barrier Terminal Socket for Channel Track
20–Pin Barrier Terminal Socket for Channel Track
Explosion Proof Housing (Meets Class1, Group D,
Class II, Group E, F, and G)
85a
Pyragon Loop Isolator
• Signal Powered CMOS Circuitry
• Precise Duplication of Input Signals
• 4–20 or 10–50 mA, Same Unit
• High Common Mode Rejection
• 1500 VRMS Isolation
• Mounts on Bulkhead or in 3" Conduit Box
Provides the Necessary Signal Isolation
for Noisy Process Circuits
If your process signals are influenced by
ground loops, high common mode noise, or
other interference, you need the Transmation
Model 10 Auto-Isolator. Requiring no separate
power supply, Auto-Isolator operates efficiently
from input signal current, and precisely
retransmits the current applied to the input
with an accuracy of ±0.1% of span.
Usable with milliamp signal ranges of 4–20,
10–50, or other ranges between 4 and 50 mA.
The instrument can be bulkhead-mounted
or installed in a 3-inch cast conduit box.
A trim potentiometer, accessible through
the instrument’s top plate, permits precise
adjustment of current transfer as a function
of load resistance up to 500 ohms at 20 mA,
and 250 ohms at 50 mA.
10AI
L
SPECIFICATIONS
Input:
Output Ratings:
ORDERING INFORMATION
10AI
10AI-EXP
Model 10 Auto-Isolator
Model 10 in Explosion Proof Housing
SIGNAL
CONDITIONERS
Accuracy:
Size/Weight:
4–20 mA, 10–50 mA, or other spans within range of 4–50 mA
4–20 mA with loads from 0–500 ohms
10–50 mA with loads from 0–250 ohms
±0.1% of span
2.95" diameter, 1.88" high/6 oz
Pyragon Universal Temperature Transmitters
• Configurable for Eight T/Cs, 12 RTDs, Millivolts, Ohms
• Unmatched Programmability: Input Type, Range, Zero, Span, Linear Output, Engineering
Units; Calibration Runs
• Exceptionally Economical: Reduces Inventory and Maintenance Costs
• Built for Reliability: RFI Protected, Isolated, Environmentally Tough, Five-Year Warranty
SPECIFICATIONS
Input Types
Thermocouple:
RTD:
2800T
L
Types J, K, T, E, R, S, N, B
Pt DIN 43760 (50, 100, 200, 500Ω); Pt JIS C 1604 (100Ω);
Pt Burns 0.003902α (100, 200, 500Ω); Ni Bristol’s 7NA
(110Ω); Ni Minco (120Ω); Cu Minco (10Ω); Cu China
0.00428α (50Ω)
mV:
-100 to + 100 mV
Resistance:
0 to 1000Ω
Accuracy:
±0.05% of span ±1 digit
Input Span Limits:
Any span within range limits
Input Resolution:
0.1°, 1 µV, 0.005Ω
Output Range:
4 to 20 mA, calibrated; 3.7 to 22 mA, maximum
Output Resolution:
0.002 mA
RTD Excitation Current: 200 µA, typical
Temperature Effect
T/C and mV:
±0.2 µV/°C max ±0.005% of input reading/°C
RTD and Ω:
±0.002 Ω/°C max ±0.005% of input reading/°C
Loop Supply Voltage:
13V + (load resistance x 20 mA), min; 48V, max
Size
3.10 x 1.75 x 3.77" HWD
ORDERING INFORMATION
2800T
2800T-EXP
2850T
100665-651
100665-652
Universal Temperature Transmitter,
Digital Display (NI FM Approved)
2800T in Explosion Proof Housing
2800T with HART Protocol
32 mm DIN Rail Adaptor—2800T
35 mm DIN Rail Adaptor—2800T
86
Weschler Process Loop Splitter
• Three Separate 4 mA to 20 mA Outputs
• DIN Rail Mounting
• Screw Terminal Connections
• Low Input Resistance
• Flexible and Simple Scaling
• Excitation Output
• Wide Power Supply Range
• Narrower Case than Previous Model
SIGNAL
CONDITIONERS
SPECIFICATIONS
Input
Input Signal:
Input Resistance:
Excitation Voltage:
Output
Number of Outputs:
Output Range:
Adjustability:
Accuracy:
Speed of Response:
Isolation:
Drive Capacity:
Power Consumption:
Operating Temperature:
Size (mm):
Mounting:
Sealing:
The TIM-018 allows one 4 to 20 mA
signal to be split into three separate
loops. Each output has its own zero
and span adjustments, which are
accessible from the front panel.
4 mA–20 mA, 0–10 mA
50Ω
20 VDC nominal, 28mA max
3
4 mA–20 mA, 0–10 mA
Zero ±1 mA, span ±9 mA
±0.1% of span
200 milliseconds
380V to earth and power
600Ω per loop
3W max
0–50°C, <90% RH non-condensing
22.5 W x 99 H x 111 D
DIN rail EN50 022
IP40
All loops are load isolated so an open
or short on one loop will not affect the
other loops. An internal 20V supply
provides sensor excitation.
L
Note: All loop + terminals are
internally connected.
TIM018-Mk2
ORDERING INFORMATION
TIM018-Mk2-AC
TIM018-Mk2-DC
Process Loop Splitter for 95-265VAC operation
Process Loop Splitter for 11-30VDC operation
Pyragon Universal Process I/O Module
•
•
•
•
•
Direct Replacement for Transmation 3000 Series Modules
Universal Input Includes TC, RTD, mADC, mVDC
4 Digit Alpha-Numeric LED Display
Input Isolated from Output and Power
4 Year Warranty
ORDERING INFORMATION
Alarm/Transmitter in Metal Case
Alarm/Transmitter w/o case
Transmitter Only
L
P3100
P3100-WOC
P3100T
The P3100 accepts a wide variety of
inputs. The 4 digit display provides a
local readout. Use the P3100 in a new
installation or to replace existing
3000 series units.
P3100
SPECIFICATIONS
Models Replaced:
3510A, 3520A, 3530A, 3540A, 3610A, 3620A, 3630A,
3640A, 3650A, 3660A, 3510DRA, 3520DRA, 3530DRA, 3540DRA,
3610DRA, 3620DRA, 3630DRA, 3640DRA, 3650DRA, 3660DRA,
3510T, 3530T, 3610T, 3630T, 3650T, 3900F, 3909F
Input Types
J, K, T, E, R, S, B, L, U, N
Thermocouple:
RTD (2 or 3 wires):
100Ω Pt (α.00385, .00392, .003916);
200, 500 & 1000Ω Pt (α.00385);
120Ω Ni and 10Ω Cu
Current:
±20 & ±50mA DC ranges
Voltage:
±1 & ±10V DC ranges
Millivolts:
±70mV
Potentiometer (3 wire) & Resistance (2 wire): 50, 200 & 2000 ranges
Frequency:
Counts/minute, Hz & kHz ranges
87
4-20mA DC (600Ω Load) or 1-5V DC,
10-50mA DC optional
LED Display:
4-Digit Alphanumeric, Decimal Point configurable
for 0, 1st, 2nd or 3rd place
Front Panel Buttons:
Relay Trip & Recovery parameters,
Relay states override, Latch reset and output manual mode
Analog Accuracy:
0.1% of Span or 10mV referred to input
Loop Power:
24VDC supply to power input mA signals up to 21mA
DPDT Relay:
Configurable delay & latching
Working Voltage:
300VAC Input to Output to Input Power
Isolation:
1000VDC Input to Output to Input Power
Configuration Interface:
RS232, 1200 baud, ASCII half duplex
Operating Temperature:
0-50°C
Power (jumper selectable):
100–240VAC, 50/60Hz and 24VDC ±10%
Signal Output:
Action Instruments Plug-In Signal Conditioners,
Isolators and Alarms
ENVIRONMENTAL SPECIFICATIONS
Isolation
Between Input, Output and Power
Limit Alarms:
1000 VDC
Signal Conditioners:
1500 VDC
Temperature Range:
Operating: 0 to 60°C
Signal Conditioners:
1500 VDC
Humidity:
15 to 95% (@45° C)
Power:
120 VAC ±10%, 50/60 Hz
Consumption:
30W Typical, 5W Max
Agency Approvals:
CSA per C22.2 and UL per UL508
ActionPak
▲
SPECIFICATIONS AND ORDERING INFORMATION
Model #
AP4380
AP4390
AP4382
AP1080
AP1090
Function
Isolator Single
Isolator Dual
Isolator (Bipolar Output)
Limit Alarm Single
Limit Alarm Dual
AP4351
Isolator
AP1280
AP1290
Limit Alarm Single
Limit Alarm Dual
AP4081
Conditioner
AP6380
Conditioner
Input
DC Volt
DC Current
Input Span (Field Configurable)
10 mV to 100V
1 mA to 100 mA
DC Volt
DC Current
Bridge
10 mV to 200V
1 mA to 100 mA
B: 500°C to 1820°C
E: -150°C to 1000°C
J: -200°C to 750°C
K: -200°C to 1370°C
R/S: 50°C to 1760°C
T: -150°C to 400°C
10 mV to ±200 mV
50 mV to 200 VAC
5 mA to 100 mA AC
10mA to 100 mA AC
2 Hz to 10 kHz
Thermocouple
AP1690
AP7380
Limit Alarm Single
Conditioner
AC Voltage
AC Current
Frequency
AP7500
Conditioner
DC (Fixed Range)
AP7501
Conditioner
DC (Fixed Range)
AP4003
Conditioner
Potentiometer
(Wide Ranging)
Specify: 4–20 mA, 0–10V,
1–5V, 0–5V, 0–10V, or 10–50 mA
Specify: 4–20 mA, 0–10V,
1–5V, 0–5V, 0–10V, or 10–50 mA
Specify: 0–100% pot
100Ω to 100Ω pots
Output (Field Configurable)
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 4–20 mA)
DC Voltage (±5V, ±10V)
Single Trip (DPDT, 5A)
Single/Dual Trip (2 SPDT, 5A)
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 4–20 mA)
Single Trip (DPDT, 5A)
Single/Dual Trip (2 SPDT, 5A)
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 4–20 mA)
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 4–20 mA)
Single/Dual Trip (2 SPDT, 5A)
DC Voltage (0–5V, 0–10V)
DC Current (0–1 mA, 4–20 mA)
Frequency (0–9 ppm up to
0–10 kHz) TTL: 0/6V
Frequency (0–0.12 ppm up to
0–130 ppm) DPDT Relay: 5A Max
DC 0-20mA, 4–20 mA, 0–5V, 0–10V
MOUNTING ACCESSORIES FOR ACTION PRODUCTS
Mounting Hardware (for ActionPak IQ and SlimPak)
MD02
TS32 DIN Rail, 2 Meters, Slotted (G-Rail)
MD03
TS35 x 7.5 DIN Rail, 2 Meters, Slotted (H-Rail)
Mounting Hardware (for Action Pak Only)
MD08
8-Pin DIN Rail Socket (Surface or Rail Mountable)
MD11
11-Pin DIN Rail Socket (Surface or Rail Mountable)
These sockets mount on standard DIN Rails MD02 or MD03
88a
84
Kobold Temperature Transmitters
L
• 4-20mA Output
• Hermetically Sealed Electronics
• Easily Re-Programmable via PC
• Low Cost and Easy Installation
TST
The TST transmitter fits in a low profile housing which is
only 2" long. PC calibration software allows temperature
range, offset, burnout options and other features to be
field selected without recalibration.
SPECIFICATIONS
Maximum Pressure:
Threaded Version:
Tri-clamp Version:
Probe Material:
Power Required:
RTD Type:
Output Accuracy:
Ambient Temperature:
1500 PSIG
500 PSIG
316 Stainless Steel
9-30 VDC loop powered
Pt100, class B
±0.1% of Span
-40°F to 158°F
• 4-20mA Output, Loop Powered
• Rugged 316 SS Construction
• -200 to 600°C Range
• Adjustable Zero & Span
The TMA series is factory calibrated.
Zero and span potentiometers are
accessible at the connector for recalibration.
SPECIFICATIONS
Ambient Temperature:
Max. Pressure:
Probe:
Power Required:
RTD Type:
Output Accuracy:
Connector:
Protection:
L
TMA
with optional
AUF display
ORDERING INFORMATION
ORDERING INFORMATION
TRANSDUCERS /
SENSORS
-40°C to +70°C
1450 PSIG
316 SS, 1/4" dia
12-36 VDC
Pt100, class B
±0.1% of Span
Hirshmann plug
NEMA 4X, IP65
To Order - Insert Code for Each Letter to Select Catalog Number.
To Order - Insert Code for Each Letter to Select Catalog Number.
Example KO/TST-A4-040-PV-06-C
Example KO/TMA-S2514A-025-05
KO/TST - A – B – C – D – E
KO/TMA - A – B – C
A Fitting Style
1
A2
/4" NPT, Adjustable immersion depth
1
A4
/2" NPT, Adjustable immersion depth
1
F2
/4" NPT, fixed immersion depth
1
F4
/2" NPT, fixed immersion depth
T15
1 1/2" Tri-clamp
T2
2" Tri-clamp
T25
2 1/2" Tri-clamp
T3
3" Tri-clamp
B Available Immersion Depth
025 2.5"
040
4"
060 6"
090
9"
120 12"
180
18"
240 24"
EP
Custom (specify)
C
Cable (6' standard length)
PV
PVC jacket (220°C process max)
TF
Teflon jacket
TA
316 SS armored
TB
316 SS braided
0
None (use for option H)(BELOW)
D Available Measuring Range
02
0 to 120°F
04
0 to 200°F
06
0 to 300°F
08
0 to 400°F
10
0 to 500°F
12
0 to 750°F
14
0 to 950°F
16
0 to 1100°F
18
-58 to 120°F
E
Custom scaling (specify)
E
Options
C
1/2" NPT conduit hub
H
DIN43650 Hirshmann Plug in place of cable
EC
Extended cable length, specify length
KO/TST-PKIT Field calibration kit includes 9pin serial cable,
110VAC power pack & Windows software
A Fitting Style
1
S2514F
/4" NPT, Fixed immersion depth
1
S2512F
/2" NPT, Fixed immersion depth
1
S2514A
/4" NPT, Adjustable depth
1
S2512A
/2" NPT, Adjustable depth
B Available Immersion Depth
025
2.5"
040
060
6"
090
120
12"
C Available Measuring Range
05
0 to 50°C (32/122 °F)
10
0 to 100°C (32/212°F)
15
0 to 150°C (32/302°F)
20
0 to 200°C (32/392°F)
40
0 to 400°C (32/752°F)
60
0 to 600°C (32/1112°F)
55
-50 to 50°C (-58/122°F)
51
-50 to 150°C (-58/302°F)
24
-200 to 400°C (-328/752°F)
26
-200 to 600°C (-328/1112°F)
E
Custom (specify)
The AUF display can be added to any 4-20 mA output that uses the
Hirshmann connector. Installed between the transmitter and the cable, the
AUF is fully scalable through two control buttons. Power is provided by the
4-20 mA loop, so no additional power supply is required.
SPECIFICATIONS
Display:
4-digit red LED 5/16" tall
Range:
-1999 to 9999
Loop Voltage Load:
5 volts
Sampling Rate: 0.33-20s, adjustable
Switch: Open Collector, 60mA max.,PNP
Protection:
NEMA 4
ORDERING INFORMATION
KO/AUF1000
109
4"
9"
Local Digital Display
KO/AUF1001
Local Display w/Alarm
Raytek Infrared Temperature Sensors
CI Series Compact Infared Sensor
MI Series Miniature Infrared Sensors
•
•
•
•
• Adjustable Emissivity,
Peak/Valley Hold &
Averaging
• 1% Accuracy from –40 to
600°C (-40 to 1112°F)
• 10:1 Optics
• Sensing Head Accessible for
Cleaning
• RS-232 Communications
(RS-485 optional)
Type J or K, or 0-5 V Output
IP 65 (NEMA-4) Stainless Steel Electronics Housing
4:1 Optics at 90% Energy
Powered by 12-24VDC at 20mA
Replaces traditional probes with J-type or K-type thermocouple output.
Functions accurately when used in conjunction with the thermocouple
break protection circuitry in most controllers, displays, and
transmitters.
SPECIFICATIONS
7 to 18 µm
±2% or ±3°C
0.5°C
350ms (95%)
fixed at 0.95
4:1
1m (3.3') standard
50Ω
50kΩ
12–24VDC ±5%, 20mA
0 to 70°C
up to 90°C
up to 260°C
10 to 95%, non-condensing
0.75" dia. x 3.4" long
SPECIFICATIONS
Resolution
Temperature Range
Outputs
Output Impedance (T/C)
Minimum Load Impedance (mV)
Maximum Loop Impedance
Power
Environmental Rating
Ambient Temperature:
MID Sensing Head
MIC Sensing Head
MIH Sensing Head
With air cooling
Electronics housing
Temperature Coefficient
Size
ORDERING INFORMATION
RA/CI-1A
RA/CI-2A
RA/CI-3A
RA/CI-1B
RA/CI-2B
RA/CI-3B
IR Temperature Sensor, J T/C, 0-155°C
IR Temperature Sensor, K T/C, 0-155°C
IR Temperature Sensor,
10mV/°C Linear Voltage, 0-155°C
IR Temperature Sensor, J T/C, 100-500°C
IR Temperature Sensor, K T/C, 100-500°C
IR Temperature Sensor,
10 mV/°C Linear Voltage, 100-500°C
OPTIONS / ACCESSORIES
-10L
-W
RA/CIADJB
RA/CIACFB
RA/CIACRA
RA/CIAP
RA/CI1CON
RA/CI2CON
RA/CIACCB10H
RA/CIACCB5OH
3m (10') Cable, 105°C
Air/water cooled jacket with
lens purge & 1m (3.3') 260°C cable
Adjustable mounting bracket
Fixed mounting bracket
Right angle mirror
Air purge collar
Thermocouple cable extension
connector kit for CI1
Thermocouple cable extension
connector kit for CI2
3 Meter (10', 260°C) extension cable
15 Meter (50', 260°C) extension cable
Spectral Response:
System Accuracy:
LT
Thermocouple output
Repeatability
System Response Time
Emissivity Transmission
0.3°C or 0.5°F
-40°C to 600°C (-40°F to 1112°F)
-25°C to 600°C for J T/C Output
4-20mA, 0-20mA, 0-5V (scaleable)
J or K thermocouple
10 mV/°C head ambient signal
20Ω
100kΩ
(mA output) 500Ω with 24VDC
power supply
11-26VDC, 100mA
IP65 (NEMA-4)
0 to 85°C (32 to 185°F)
0 to 125°C (32 to 257°F)
0 to 180°C (32 to 356°F)
up to 200°C
0 to 65°C
MID 0.15K/K or 0.15%/K
MIC, MIH 0.05K/K or 0.05%/K
Sensor 0.55" dia x 1.1" long
Housing 3.2" x 2.4" x 1.0"
8 to 14 µm
(18-28°C ambient)
±1% or ±1°C
±1% or ±2.5°C
±0.5% or ±0.5°C
150ms (95%)
0.100 to 1.100 digitally adjustable
ORDERING INFORMATION
RA/MID-10LT Univ. Output, 10:1 optics, 1m cable, 85°C max sensor ambient
RA/MIC-10LT Univ. Output, 10:1 optics, 1m cable, 125°C max sensor ambient
RA/MIH-10LT Univ. Output, 10:1 optics, 1m cable, 185°C max sensor ambient
OPTIONS/ACCESSORIES
-4
- CB3
- CB8
- CB15
-V
RA/XXXMIACFB
RA/XXXMIACAB
RA/XXXMIACAJ
RA/XXXMIACCJ
RA/XXXCIDCPS
RS485 Multidrop Communication
3m (10') Cable
8m (26') Cable
15m (49') Cable
Display window in electronic housing
Fixed Mounting Bracket
Adjustable Mounting Bracket
Air Purge Collar
Air Cooling and Purge System
(includes 2.8' insulated air hose)
Power Supply, 24VDC
110
TRANSDUCERS /
SENSORS
Spectral Response
Accuracy
Resolution
Response Time
Emissivity
D:S Ratio
Cable
Output Impedance (J/K)
Minimum Load (mV)
Power
Ambient Temperature:
Sensing head
With air cooling
With water cooling
Relative Humidity
Size
Two-piece infrared temperature measurement system with a
miniature sensing head and die-cast electronics housing.
Raytek Programmable
IR Sensors
Kobold Ultrasonic Level
Transmitter
• Measuring ranges to 23 feet in liquids,
11.5 feet in solids
• Narrow 5.5° beam angle
• PVDF wetted parts
• Accuracy 0.25% of full scale
• 2-wire and 4-wire versions
L CM
TRANSDUCERS /
SENSORS
•
•
•
•
•
•
•
-20 to 500°C (-4 to 932°F) Range
13:1 Optics at 90% Energy
150ms (95%) Response Time
RS-232 Digital Communications
Adjustable Signal Processing
DataTemp® Multidrop Software Compatible
Sensor status indicator LED
Designed for easy integration, the CM sensor with J-type or
K-type thermocouple output can easily replace traditional
contact probes. A user scalable 0-5 volt output is available for
applications susceptible to noise. This rugged, single piece
NEMA4 sensor has silicon optics to provide excellent optical
resolution.
SPECIFICATIONS
Accuracy (mV):
Accuracy (T/C):
Spectral Response:
Resolution:
Emissivity:
Transmissivity:
Signal Processing:
Output:
Self-diagnostics:
Power Supply:
Digital Output:
Alarm Output:
Ambient Temperature:
Housing:
Size:
Cable:
± 1.5% of reading or ± 2ºC
± 1.5% of reading or ± 4ºC
8 to 14 microns
0.1°C
0.10 to 1.10 (adjustable)
0.10 to 1.00 (adjustable)
Peak hold, valley hold, variable averaging
100Ω Zout (TC types)
50kΩ min load (Voltage type)
Alarm, out of range, unstable, fault
12–24 VDC ±20% @ 10mA
Two-way RS232 digital output
Transistor, 24VDC ±20% <20mA
0-70°C (32-160°F)
IP 65 (NEMA-4) stainless steel
0.75" dia x 3.7" long, 3/4-16 UNF thread
1m (3.3 ft) standard, 3m available
ORDERING INFORMATION
RAYCMLTV
RAYCMLTJ
RAYCMLTK
Add suffix 3 for 3m (9.8') cable
111
CM sensor, 0-5V user-scalable output
CM sensor, Type J TC output
CM sensor,Type K TC output
The NUS series Ultrasonic Level
Transmitter is ideal for continuous,
non-contact level measurement in liquids
and coarse grained or pelletized solids.
This sensor allows reliable measurement of
dirty, viscous, and coating medium. The NUS
boasts an extremely narrow beam to minimize
problems due to obstructions in tall tanks.
In addition to the 4-20mA output,
a front panel LED readout is available.
L 2083
The NUS series offers many advanced features including 11
point linearization, fixed echo suppression, automatic stirrer
echo suppression and output dampening. These features allow
the NUS series to be used in applications which render most
other ultrasonics useless. Calibration and setup is a simple
task performed using a push-button driven menu.
SPECIFICATIONS
Maximum Pressure:
Process Temperature:
Accuracy:
Resolution:
Beam Cone Angle:
Maximum Loop Load:
Optional Display:
Case:
Protection:
Electrical Connection:
Measuring Range
2" NPT Models:
1 1/2" NPT Models:
40 PSIG
-40°F to 176°F
0.25% of Max. Range
±0.12"
5.5°
600Ω
4 digit LED
Epoxy coated Aluminum
NEMA 4X, IP65
1
/2" NPT
1.3 to 23.0 ft in liquids,
1.3 to 15 ft in solids
0.8 to 13.1 ft in liquids,
0.8 to 6.6 ft in solids
ORDERING INFORMATION
KO/NUS-1053N
KO/NUS-1051N
KO/NUS-2053N
KO/NUS-2051N
KO/NUS-1083N
KO/NUS-1081N
KO/NUS-2083N
KO/NUS-2081N
1 1/2" fitting, 12-36VDC, 2-wire Transmitter
1 1/2" fitting, 90-127VAC, 4-wire Transmitter
1 1/2" fitting, 12-36VDC, 2-wire with Display
1 1/2" fitting, 90-127VAC, 4-wire with Display
2" fitting, 12-36VDC, 2-wire Transmitter
2" fitting, 90-127VAC, 4-wire Transmitter
2" fitting, 12-36VDC, 2-wire with Display
2" fitting, 90
Vaisala Humidity & Temperature Transmitters
• Measure humidity, temperature,
dew point, mixing ratio, absolute
humidity and wet bulb temperature
• Small sensor head for use
in tight spaces
• Small sensor mass for
fast response
• Graphical display shows
trends & 1 year history
• Analog & alarm relay outputs
• Corrosion resistant
NEMA 4 (IP65) housing
• Single point field calibration
ORDERING INFORMATION
To Order—Insert Code for Each Letter to Select Catalog Number.
Order Example: HMT333 E0B201BCDC1B01AABC
HMT333 A
B
C
D
L
M
N
O
A
B
HMT333
L
The HMT333 Transmitter is a full featured front end for industrial and
commercial humidity measurements. The HMT333 sensor provides
accurate reading with excellent long-term stability, over the entire
temperature range. The sensor is immune to particle contamination
and most chemicals. A chemical purge to clean the sensor (via heating)
can be initiated manually or at set intervals.
Two analog outputs easily connect to meters, controllers, recorders and other
equipment. The RS-232 interface simplifies setup and calibration. RS-485 &
Ethernet options permit networking the HMT333 with other devices. Windows
software is available to download and display the measurement data.
C
D
E
F
Datalogger option records up to 4 years of data.
Optional:
Temperature Range:
Accuracy at 20°C:
Temperature dependence:
Temperature sensor:
RH Accuracy:
0-90 %RH:
90-100 %RH:
Response time:
Accuracy of analog output:
External loads:
Current outputs:
0-1V output:
0-5V & 0-10V outputs:
Power consumption @24VDC:
Operating temperature:
with local display:
Keypad:
Display menus:
Alarm relays:
RS 485/422 interface:
Dimensions:
Housing:
Probe:
Relative Humidity (RH)
Temperature (T)
Dewpoint Temperature (Td)
Absolute Humidity g/m3 (a)
Wet Bulb Temperature (Tw)
Mixing Ratio g/Kg (x)
Enthalpy (h)
-40 to 80°C (176 °F)
±0.2°C
±0.0025°C/°C
Pt100 class B
±2% RH
±1.7% RH
8 sec. in still air
±0.05% full scale
<500Ω
>2kΩ
>10kΩ
110mA max, 220ma during purge
-40 to 60°C (-40 to 140°F)
0 to 60°C (32 to 140°F)
Sealed pushbuttons
English, Spanish, French, German,
0.5A@250VAC, SPDT
Full or half duplex, 9600 baud
G
H
I
J
K
L
M
N
7.2x4.7x3.0" (183x119x77mm)
3.5" x 0.5"dia (89x 12mm)
O
Additional HMT330 models available for high temperature (180°C), high
pressure, vacuum, high humidity and other applications. Also available:
HMT360 Series Intrinsically Safe Transmitters.
F
G
H
I
J
K
Cable Length
E0
2m (6.5ft)
F0
5m (16.3ft)
G0
10m (32.5ft)
Transmitter Type
A
RH+T
B
RH+T+Td+Tdf+a+Tw+x+ppm+pw+pws+h+dT
Display
0
No display
1
Graphic LCD with keypad
Power Supply, Alarm Output
0
10-35 VDC, 24 VAC
1
10-35 VDC, 24 VAC isolated
3
100-240 VAC with 115V cord
Analog Output Level
1
4-20 mA
2
0-20 mA
3
0-1 V
4
0-5 V
5
0-10 V
Analog Output Signal (3 digits: Ch1, Ch2, Ch3)
B
RH
0 to 100%RH
C
T
D
Td
-20 to +100 °C (-4 to +212 °F)
E
Tdf
-20 to +100 °C (-4 to +212 °F)
F
a
0 to 600 g/m3 (0 to +262 gr/ft3)
G
Tw
0 to +100 °C (32 to 212 °F)
H
x
0 to 500 g/kg d.a. (0 to 3500 gr/lb d.a.)
J
h
-40 to 1500 kJ/ kg (-17.2 to 644.9 Btu/lb)
K
ppm
0 to 5000
L
pw
0 to 1000 hPa (0 to 14.5 psi)
M
pws
0 to 1000 hPa (0 to 14.5 psi)
N
dT
-10 to 50 °C (14 to 122 °F)
Analog Output Range for Temperature
C
-40 to +80 °C (-40 to +176 °F)
D
-40 to +120°C (-40 to +248°F)
Output Units
1
Metric
2
Non-metric
Options (2 Digits: Slot 1, Slot 2)
1
Relay Output
2
RS-485
4
Ethernet (requires external power)
6
Datalogger
0
None
Cable Fitting
A
Cable gland M20*1.5
1
B
/2 NPT conduit fitting
Mounting
0
Normal
1
Wall plate
4
DIN rail
Humidity Sensor
1
General purpose, Humicap180
2
with sensor purge, Humicap180C
Sensor Protection
A
PPS grid & stainless steel netting (14 microns)
B
PPS plastic grid
C
Sintered stainless filter
Installation Kit
AB
None
BB
Duct
PC Accessories
A
None
B
Serial cable
C
Software & cable
114
TRANSDUCERS /
SENSORS
SPECIFICATIONS
Parameters:
Standard:
E
Kobold Digital Temperature Sensor
Programmable Features
• Lockout Code
• Dampening
• Transmitter Span
L
• Measuring Range
-58 to 250°F
• Semiconductor Sensor
• Scalable 4-20mA Output
• Easy-to-Read LED Display
• All Stainless Steel
Construction
SPECIFICATIONS
Display Type:
Display Resolution:
Accuracy:
TRANSDUCERS /
SENSORS
Pressure:
Process Temp:
Ambient Temp:
Material:
Remote Probe Cable:
Power:
Output:
Sample Rate:
Dampening:
Electrical Connection:
Electrical Protection:
ORDERING INFORMATION
TDA
3-digit red LED
0.5° from -10° to +100°,
1° below -10 and above 100°
14 to 185°F: ±0.9°F
14 to -58°F: ±3.6°F
185 to 250°F: ±3.6°F
1150 PSIG max.
250°F max.
120°F max.
316L Stainless Steel housing & probe
Teflon, 8ft. std.
24 VDC ±20% @ 20 mA
4-20 mA, 3-wire, 500Ω max. load
0.5 Sec./sample
Averaging 2, 4,8, 16, 32, or 64 samples
4-Pin Micro-DC male plug or PVC jacketed cable
NEMA 4/IP 65
To Order: Insert Code for Each Letter to Select Catalog Number
TDA -15 – A – B – C – D
A
B
C
D
Process Connection
N4
1/2" NPT
N5 3/4" NPT
R4
1/2" BSP
R5 3/4" BSP
D6 Remote Probe (Smooth Shank)
Measuring Range
F2
0 to 250°F
F3
-58 to 250°F (only available with Remote Probe)
H2
-20 to 120°C
H3
-50 to 125°C (only available with Remote Probe)
Probe Length
0
12mm / 1/2" (not Available with Remote Probe)
1
100mm / 4"
2
185mm / 7.25" (not Available with Remote Probe)
Electrical Connection
L3M Micro-DC plug, 4-Pin male
L3P 3 Ft. PVC cable
L3S Custom length PVC cable
Kobold Magneto-Inductive Flowmeters
L
• Flow Rates from 0.26 GPM
to 200 GPM
• Use with Conductive Liquids,
Acids & Caustic
• No Moving Parts
• Digital Display Option
• Frequency or mA Output
MIK-C34
Conductivity >30 µS/cm
±2.0% of full scale
±1% of full scale
Requires 3X dia. upstream, 2X downstream
32–176°F (140°F max. with PVC fittings)
145 PSIG max @ 70°F
3.6 PSI max @ 100% rated flow
NEMA 4X/IP 65
24 VDC ±20% required
Micro-DC male, 4-pin (5-pin on C34)
PNP open collector, 200 mA max.
4–20 mA, 3-wire, 500Ω max.
PNP or NPN open collector, 300 mA max.
Compact electronic units (C34 Output Type) have a digital display and programmable switch setpoint, reset point, switch logic, 4–20 mA span/zero, dampening & lockout code. Set via 2-button keypad. Models with Integral Totalizer &
Batch Controller electronics are also available.
NEW
ORDERING INFORMATION
MIKA
B
SPECIFICATIONS
Liquid:
Accuracy:
Repeatability:
Straight Pipe:
Operating Temp.:
Pressure:
Pressure Drop:
Electrical Protection:
Power Supply:
Connector:
Frequency Output
Analog Output
Switch Output
Example TDA-15-N4-F2-0-L3M
C
D
A – B – C – D
Example MIK-5NAU4NL343
Body Mat er ial
5NA
Ryton with Buna-N Seal, 316L Electrode
5VA
Ryton with FKM Seal, 316L Electrode
6FC
PVDF with FFKM Seal, Hastelloy C4 Electrode
Range
Fitting Set Size (")
GPM
N
P
M
U1
0.013-0.26
1/4
1/2
-U2
0.04-0.8
U4
0.13-2.6
3/8
3/4
3/8
U5
0.2-4.0
U7
0.4-8.0
1/2
1
1/2
U8
0.65-13
UA
0.8-16
1
-1
UB
1.3-26
UD
2.0-40
1-1/2
-1-1/2
UE
4.0-80
UG
6.5-130
2
-2
UH
10-200
Fitting Se t*
N
NPT female PVC
P
PVC hose barb
M
PVC glue socket
A
BSPP male
Output
F300
Frequency 0-500Hz
F390
User Specified 50-1000Hz full scale
L343
4-20mA
C34N 4-20mA & NPN switch
C34P
4-20mA & PNP switch
A
1/2
1/2
1
1-1/2
2
2-3/4
* PVDF butt weld tube & polypro NPT female fittings also available for some ranges.
115
Download PDF
Similar pages