VER:1.0 │
│ 22.04.2015
ABB-Welcome
Pos : 2 /Di nA4 - Anleitung en Online/Inhalt/KN X/D oorEntr y/83220- AP- xxx/Titelbl att - 83220-AP- xxx - ABB @ 19\mod_1323249806476_15.doc x @ 111084 @ @ 1
M2302
Gateway
=== Ende der Liste für T extmar ke Cover ===
ABB-Welcome
Pos : 4 /Busch-J aeger (Neus truktur)/M odul-Str uktur/Online-Dokumentation/Inhal ts verz eic hnis (--> Für alle D okumente <--)/Inhalts verz eichnis @ 19\mod_1320649044386_15.doc x @ 109653 @ @ 1
1
2
3
4
5
6
Safety ............................................................................................................ 3
Intended use ..................................................................................................3
Environment ..................................................................................................3
3.1
ABB devices ................................................................................. 4
Operation ....................................................................................................... 5
4.1
Control elements .......................................................................... 5
4.2
Operating modes .......................................................................... 7
4.2.1
Building gateway .......................................................................... 7
4.2.2
Floor gateway ............................................................................. 10
4.2.3
Apartment gateway ..................................................................... 15
4.2.4
Additional power supply mode .................................................... 20
4.2.5
Line amplifier .............................................................................. 24
Technical data ............................................................................................. 27
Mounting / Installation .................................................................................. 28
6.1
Requirements for the electrician ................................................. 28
6.2
General installation instructions .................................................. 29
6.3
Mounting ..................................................................................... 29
=== Ende der Liste für T extmar ke TOC ===
|
—2—
ABB-Welcome
Safety
Pos : 6 /Busch-J aeger (Neus truktur)/M odul-Str uktur/Online-Dokumentation/Ü bers chriften (--> Für alle Dokumente <--)/1. Ebene/S - T/Sicherheit @ 18\mod_1302612791790_15.doc x @ 103357 @ 1 @ 1
1
Safety
Pos : 7 /Busch-J aeger (Neus truktur)/M odul-Str uktur/Online-Dokumentation/Sicherheit (--> Für all e D okumente <--)/Warnhi nweis e/Sicherheit - 230 V @ 18\mod_1302606816750_15.doc x @ 103308 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 100-240 V.
–
Work on the 100-240V supply system may only be performed by
authorised electricians!
–
Disconnect the mains power supply prior to installation and/or
disassembly!
Pos : 8 /Busch-J aeger (Neus truktur)/M odul-Str uktur/Online-Dokumentation/Ü bers chriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Bes ti mmungsgemäßer Gebrauc h @ 18 \mod_1302763321316_15.doc x @ 103483 @ 1 @ 1
2
Intended use
Pos : 9 /Di nA4 - Anleitung en Online/Inhalt/KN X/D oorEntr y/83220- AP- xxx/Besti mmungsg emaess er Gebrauch - 83220-AP- xxx- 500 @ 20\mod_1324561168699_15.doc x @ 112728 @ @ 1
The M2302 gateway is an integral part of the ABB Welcome door communication system
and operates exclusively with components from this system. The device must only be
installed on mounting rails according to DIN EN 500022.
Pos : 10 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Übersc hriften (--> Für alle D okumente <--)/1. Ebene/U - Z/U mwelt @ 18\mod_1302614158967_15.doc x @ 103383 @ 1 @ 1
3
Environment
Pos : 11 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/U mwel t (--> Für alle D okumente <--)/Hinweis e/Hi nweis - U mwelt - Hinweis Elektrog eräte @ 18\mod_1302763973434_15.doc x @ 103500 @ @ 1
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with
domestic waste.
–
The device contains valuable raw materials which can be recycled.
Therefore, dispose of the device at the appropriate collecting
depot.
Pos : 12 /DinA4 - Anl eitungen Onli ne/Ueberschriften/2./ABB Geraete @ 19\mod_1323162843832_15.doc x @ 110875 @ 2 @ 1
|
—3—
ABB-Welcome
3.1
Environment
ABB devices
Pos : 13 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/U mwel t (--> Für alle D okumente <--)/Hinweis e/Hi nweis - U mwelt - ABB El ektr ogeräte @ 19\mod_1323162745839_15.doc x @ 110867 @ @ 1
All packaging materials and devices from ABB bear the markings and test seals for
proper disposal. Always dispose of the packaging material and electric devices and their
components via the authorized collecting depots and disposal companies.
ABB products meet the legal requirements, in particular the laws governing electronic
and electrical devices and the REACH ordinance.
(EU-Directive 2002/96/EG WEEE and 2002/95/EG RoHS)
(EU-REACH ordinance and law for the implementation of the ordinance (EG)
No.1907/2006)
|
—4—
ABB-Welcome
Operation
Pos : 18 /DinA4 - Anl eitungen Onli ne/Ueberschriften/1./Bedi enung @ 18\mod_1302613924165_15.doc x @ 103365 @ 1 @ 1
4
Operation
Pos : 19 /DinA4 - Anl eitungen Onli ne/Ueberschriften/2./Nor maler Betrieb @ 18\mod_1302768820965_15.doc x @ 103540 @ 2 @ 1
4.1
Control elements
Pos : 20 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Bedi enel emente @ 20\mod_1323260220559_15.doc x @ 111647 @ 3 @ 1
Pos : 21 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/83220-AP- xxx/Bedi enelemente - 83220- AP- xxx @ 18\mod_1303212853605_15.doc x @ 103673 @ @ 1
Fig. 1:
Overview of control buttons
No.
Functions
1
Bus in/out
2
Operating mode settings: See chapter on 'Operating modes' for details
3
Terminal resistor ON / OFF.
In video installations or audio- and video-combined installations, the switch
must be set as 'RC on' on the last device of the line.
4
Rotary switches for addressing (01-99).
5
Connection with outdoor stations, or connection with bus in, in "line
amplifier" mode.
|
—5—
ABB-Welcome
6
Operation
Operating status indicating LED
Pos : 22 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okumentation (--> F ür all e D okumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
|
—6—
ABB-Welcome
Operation
Pos : 26 /DinA4 - Anl eitungen Onli ne/Ueberschriften/2./Bedi enaktionen @ 20\mod_1323262294281_15.doc x @ 111911 @ 2 @ 1
4.2
Operating modes
Pos : 71 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Absc hlus s widerstand @ 19\mod_1321958079906_15.doc x @ 110083 @ 3 @ 1
Pos : 72 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Bedienung/Absc hl uss widerstand setzen 83220-AP- xxx @ 19\mod_1310723392369_15.doc x @ 107841 @ @ 1
4.2.1
Building gateway
1
ON
1 2 3
Fig. 2:
Building gateway
No.
Functions
1
1->OFF, 2->OFF, 3->OFF
Pos : 74 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Bedienung/Master/Sl ave Schalter s etz en 83220-AP- xxx @ 19\mod_1310723320966_15.doc x @ 107833 @ @
|
—7—
ABB-Welcome
Operation
Enable one building as an independent sub-system(-outdoor station(s)/ -guard unit(s)
can be connected). Up to 60 such systems are supported within the whole system.
The gateway address is equal to the riser number.
Fig. 3:
Building gateway
Wiring diagram:
|
—8—
ABB-Welcome
Fig. 4:
|
Operation
Building gateway
—9—
ABB-Welcome
4.2.2
Operation
Floor gateway
1
ON
1 2 3
Fig. 5:
Floor gateway
No.
Functions
1
1->OFF, 2->OFF, 3->ON
|
— 10 —
ABB-Welcome
Operation
Enable a multi-apartment as an independent sub-system(another outdoor station can be
connected, for example in front of the door of the floor with the multi-apartment).
The gateway address is equal to the minimum address of the indoor station inside the
sub-system.
Fig. 6:
|
Floor gateway
— 11 —
ABB-Welcome
Operation
Wiring diagram:
Fig. 7:
Floor gateway
If using pushbutton outdoor station as a gate station, f loor gateway is available for this
kind of use case.
In following example an outdoor station is mounted at the gate entrance with which all
six apartments can be called. One outdoor station is on the left building with apartments
01 and 03 and a further outdoor station on the right building with apartments 04 and 05.
|
— 12 —
ABB-Welcome
Operation
This means that only three apartments can be called from these two outdoor stations.
Using floor gateway for each building, and outdoor station 1 can manage these two
buildings, while outdoor station 2 manage the left building and outdoor station 3 manage
the right one.
Apartment 01 A
Apartment 02 B
Apartment 03 C
Apartment 01 A
Apartment 04 D
Apartment 04 A
Apartment 02 B
Apartment 05 E
Apartment 05 B
Apartment 03 C
Apartment 06 F
Apartment 06 C
Outdoor station
Outdoor station
Outdoor station
Left building
Gate entrance
Right building
Wiring diagram (using floor gateway for each building) :
|
— 13 —
ABB-Welcome
ST. X100 X10 X1
ST. X100 X10 X1
Operation
ST. X100 X10 X1
Address
Apartment 01 A
Apartment 02 B
Apartment 03 C
|
Address
Address
ST. X100 X10 X1
ST. X100 X10 X1
ST. X100 X10 X1
Apartment 01 A
Apartment 02 B
Apartment 03 C
Apartment 04 D
Apartment 04 A
Apartment 05 E
Apartment 05 B
Apartment 06 F
Apartment 06 C
M2302
M2302
X10 X1
X10 X1
— 14 —
ABB-Welcome
4.2.3
Operation
Apartment gateway
1
ON
1 2 3
Fig. 8:
Apartment gateway
No.
Functions
1
1->OFF, 2->ON, 3->OFF
|
— 15 —
ABB-Welcome
Operation
Enable one apartment as an independent sub-system (The 2nd confirmed outdoor
station can be connected). Up to 99 such systems can be supported within the whole
system.
The gateway address is equal to the apartment number.
|
— 16 —
ABB-Welcome
Fig. 9:
|
Operation
Apartment gateway
— 17 —
ABB-Welcome
Operation
Wiring diagram:
|
— 18 —
ABB-Welcome
|
Operation
— 19 —
ABB-Welcome
Fig. 10:
4.2.4
Operation
Apartment gateway
Additional power supply mode
1
ON
1 2 3
Fig. 11:
Additional power supply mode
No.
Functions
1
1->OFF, 2->ON, 3->ON
|
— 20 —
ABB-Welcome
Operation
Enable an additional power source for systems with a system controller.
★
★
Using gateway
+ system
controller as
auxiliary power
supply to
connect to
other indoor
stations in the
same building,
when one
system
controller can’t
cover all
consmer units.
★
Fig. 12:
|
Additional power supply mode
— 21 —
ABB-Welcome
Operation
Wiring diagram:
|
— 22 —
ABB-Welcome
Fig. 13:
|
Operation
Additional power supply mode
— 23 —
ABB-Welcome
4.2.5
Operation
Line amplifier
1
ON
1 2 3
Fig. 14:
Line amplifier
No.
Functions
1
1->ON, 2->OFF, 3->OFF
|
— 24 —
ABB-Welcome
Operation
Strengthen the video signal and extend transmission. The increased distance please
refer to ABB-Welcome system manual.
Fig. 15:
|
Line amplifier
— 25 —
ABB-Welcome
Operation
Wiring diagram:
Fig. 16:
Line amplifier
Pos : 75 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okumentation (--> F ür all e D okumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
|
— 26 —
ABB-Welcome
Technical data
Pos : 76 /DinA4 - Anl eitungen Onli ne/Ueberschriften/1./Tec hnisc he D aten @ 18\mod_1302615863001_15.doc x @ 103416 @ 1 @ 1
5
Technical data
Pos : 77 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/83220-AP- xxx/T ec hnische D aten - 83220-AP- xxx @ 18\mod_1303212854559_15.doc x @ 103705 @ @ 1
Designation
Value
Operating temperature
Protection
-25 °C - +55 °C
Single-wire clamps
Fine-wire clamps
Bus voltage
IP 20
2 x 0,28 mm² – 2 x 1 mm²
2 x 0,28 mm² – 2 x 1 mm²
20-30V
Pos : 78 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okumentation (--> F ür all e D okumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
|
— 27 —
ABB-Welcome
Mounting / Installation
Pos : 79 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Übersc hriften (--> Für alle D okumente <--)/1. Ebene/M - O/Montage / Installation @ 18\mod_1302613966111_15.doc x @ 103373 @ 1 @ 1
6
Mounting / Installation
Pos : 80 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Sic herheit (--> Für alle Dokumente <--)/Warnhinweis e/Sic herheit - Ni eders pannungs- und 230 V-Leitungen @ 18\mod_1302617821491_15.doc x @ 103465 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 100-240 V.
–
Low-voltage and 100-240 V cables must not be installed together in
a flush-mounted socket!
In case of a short-circuit there is the danger of a 100-240 V load on
the low-voltage line.
Pos : 81 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Sic herheit (--> Für alle Dokumente <--)/Warnhinweis e/Sic herheit - F ac hkenntniss e @ 18\mod_1302774384017_15.doc x @ 103564 @ 2 @ 1
6.1
Requirements for the electrician
Warning
Electric voltage!
Install the device only if you have the necessary electrical engineering
knowledge and experience.
•
Incorrect installation endangers your life and that of the user of the
electrical system.
•
Incorrect installation can cause serious damage to property, e.g.
due to fire.
The minimum necessary expert knowledge and requirements for the
installation are as follows:
•
|
Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1.
Disconnect from power;
2.
Secure against being re-connected;
3.
Ensure there is no voltage;
4.
Connect to earth;
5.
Cover or barricade adjacent live parts.
— 28 —
ABB-Welcome
Mounting / Installation
•
Use suitable personal protective clothing.
•
Use only suitable tools and measuring devices.
•
Check the type supply network (TN system, IT system, TT system)
to secure the following power supply conditions (classic connection
to ground, protective earthing, necessary additional measures,
etc.).
Pos : 82 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Montage/M ontagehinweise - Allgemein @ 19\mod_1310563670478_15.doc x @ 107743 @ 2 @ 1
6.2
•
General installation instructions
Terminate all branches of the wiring system via a connected bus device (e.g.,
indoor station, outdoor station, system device).
•
Do not install the system controller directly next to the bell transformer and other
power supplies (to avoid interference).
•
Do not install the wires of the system bus together with 100-240 V wires.
•
Do not use common cables for the connecting wires of the door openers and wires
of the system bus.
•
Avoid bridges between different cable types.
•
Use only two wires for the system bus in a four-core or multi-core cable.
•
When looping, never install the incoming and outgoing bus inside the same cable.
•
Never install the internal and external bus inside the same cable.
6.3
Mounting
Pos : 85.1 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/DoorEntr y/83220-AP- xxx/M ontag e - M odul e/Montage - Montagedose -- 83220-AP- xxx @ 19\mod_1323250406848_15.doc x @ 111098 @ @ 1
The device M2302 must only be installed on mounting rails according to DIN EN
500022.
|
— 29 —
ABB-Welcome
Mounting / Installation
Pos : 83 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okumentation (--> F ür all e D okumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
|
— 30 —
ABB-Welcome
Mounting / Installation
Pos : 95 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Pr ojektier ung-Mer kblatt/Proj ekti erPos: 97 /Busch-J aeger (Neus truktur)/M odul-Str uktur/Online-Dokumentation/R üc ks eiten (--> Für alle D okumente <--)/Rüc ks eite - Busc h-Jaeger - Allgemein @ 20\mod_1327320074886_15.doc x @ 137103 @ @ 1
Notice
=== Ende der Liste für T extmar ke Bac kc over ===
We reserve the right to at all times make technical changes as well as changes to the
contents of this document without prior notice.
The detailed specifications agreed to at the time of ordering apply to all orders. ABB
accepts no responsibility for possible errors or incompleteness in this document.
We reserve all rights to this document and the topics and illustrations contained
therein. The document and its contents, or extracts thereof, must not be reproduced,
transmitted or reused by third parties without prior written consent by ABB.