RolSmart M-K roller shutter drive
Keep these instructions in a safe place!
After installation of the tubular drive attach these instructions to the cable for the electrician.
Device functions:
As-delivered condition (commissioning mode)
• Setting end positions
Warning!
Important safety instructions!
Observe the following instructions.
Risk of injury due to electrocution.
The connections to the 230 V mains must be made by authorised specialist personnel.
Check the system (roller shutter) regularly for wear or damage.
The regulations of the local energy supply company as well as the regulations for wet and damp rooms according to VDE 0100 must be followed when making the connections.
Only use unmodified original elero electrical parts.
Keep people away from the system until it is
stationary.
When working on the system (servicing, cleaning windows etc.), always disconnect it from the mains supply.
Check the following before installation:
• The drive is only capable of operation as installed.
• Only perform connecting work with the power turned off.
• The blind must be attached to the winding shaft.
• The profile tube must have sufficient clearance from the motor tube.
• Make sure there is sufficient axial play (1–2 mm)
Installation in profile tubes
Ⓐ
Push drive with relevant adapter
and limit switch into the profile
tube.
Protect the motor cable in order
to avoid it brushing against the
roller shutter. Avoid kinking the
cable.
Ⓑ
Secure the counterpart support to prevent axial movement, e.g. screw or rivet on idler.
Secure the drive axially in the
support.
Ⓒ
Attach the blind to the shaft!
A
C
B
Warning!
Risk of injury due to electrocution.
Do not drill in the area of the motor!
Installation
Warning!
Observe the following installation instructions!
– The drive must be fixed in such a way that it does not endanger personnel.
– Before installing the drive, all lines and equipment, which are not required for operation, must be removed from the site.
– During installation, during operation and when work is carried out on the system, the option to separate all three poles from the mains must always exist (Hirschmann connector and
Hirschmann coupling or a two-pole switch with minimum 3 mm contact gap or all-pole main switch).
– Parallel switching only with sequencing relay.
– If the drive is controlled by a switch with OFF pre-setting (dead man’s button), the momentary contact switch must be fitted at a height of more than 1.50 m and separated from the moving parts.
The travel range of the systems must always be visible during operation.
– Moving parts in a drive, which are below 2.5 m, must be guarded.
– Set torque and set operating time must be
adapted to the requirements of the product which is driven.
Please note the technical data on the type plate.
– Please note that with this drive (type M motor) the smallest internal tube diameter corresponds with
46 mm.
– The drive must be installed so that it cannot get wet.
– Do not install drives in surroundings which are at risk of explosion or in mobile appliances
(e.g. motor vehicles).
– Keep children away from the (remote) control unit.
Remove of the motor cable plug
Risk of injury due to
electrocution.
Warning!
When the motor cable plug is removed the supply line
must be volt free.
Delivery condition Remove plug
2
→
1
→
Insert plug
→
3
Remove the motor cable plug
Switch off voltage supply.
1. Press locking mechanism on the plug towards the cable using a screwdriver.
2. Pull out the plug.
Insert the motor cable plug
3. Switch off voltage supply. Insert plug until locking mechanism
engages.
138141401_EN_1113
Connection/Installation/Commissioning
Types of installation
Different types of installation are possible::
Type of installation
1. Fixed upper stop
lower stop freely
adjustable
2. Fixed upper and
lower stop
3. Upper stop freely
adjustable
fixed lower stop
Possible with
T-strap, tapes, belt, limit plugs, angle bracket
Anti push-up device, limit plugs, angle bracket
Anti push-up device
Start up
Please note: The RevoLine RolSmart M-K requires a defined
limit stop (upper or lower limit position).
For free programming of both positions, please select a RevoLine RolTop.
Note: The drive is in commissioning mode when the roller
shutters are delivered.
Assembly cable connection
1.
Connection example, RolSmart M-K Tubular Motor
230 V/50 Hz
Note:
The motor controls in up/down direction must be locked against each other.
A reversing delay of at least 0,5 sec. must be ensured.
Condenser
Electronics
Winding thermostat
Motor cable plug
Junction box
(outside of roller shutter case) interlocked push button or momentary contact switch
1 0 2
Mains 230V/50 Hz
L1
N
PE
Switch box
3
2
1
3
2
1
Blue (neutral conductor)
Black (2)
Brown (3)
Green-yellow
2. Switch on mains.
You can now set the end positions with the assembly cable.
Please note: Press the travel key until the drive signals the
transition into the programming mode, by a short automatic STOP.
You can now program the end positions.
Note: The blind protection system is only adapted to the blind after a complete, uninterrupted upwards and downwards travel.
Note: Parallel switching only possible with sequencing relay.
Mains ele ro
2 | EN
End position setting
Installation Method 1: Fixed upper stop/ lower stop freely adjustable
Installation Method 1: Fixed upper stop/lower stop freely adjustable
Note: Ensure that the equipment is correctly connected.
STOP
STOP
4. Press the DOWN momentary contact switch again.
Move the blind down until it is a short distance above the
desired lower limit stop.
The drive starts up slowly with a short STOP.
1. Move the blind up to approx. 5 cm before the upper limit stop.
The drive starts up slowly with a short STOP.
STOP
2. Press the UP momentary contact switch again.
Approach the upper limit stop.
The drive switches off automatically when it reaches the limit stop.
5. Travel to the desired lower limit stop.
It is possible to make corrections using the momentary contact switches.
STOP
STOP
3. Press the DOWN momentary contact switch until the drive stops automatically.
The upper limit stop is programmed.
6. Press the UP momentary contact switch until the drive stops automatically.
The lower limit has been set.
Setting of the end positions is now complete.
EN | 3
End position setting
Installation Method 2: Fixed upper and lower stop
Installation Method 2: Fixed upper and lower stop
Note: Ensure that the equipment is correctly connected.
STOP
STOP
4. Press the DOWN momentary contact switch again.
Run the blind until shortly before the lower limit stop.
The drive starts up slowly with a short STOP.
1. Move the blind up to approx. 5 cm before the upper limit stop.
The drive starts up slowly with a short STOP.
STOP
STOP
5. Travel slowly to the lower limit stop.
The drive switches off automatically when it reaches the limit stop.
2. Press the UP momentary contact switch again.
Approach the upper limit stop.
The drive switches off automatically when it reaches the limit stop.
STOP
STOP
3. Press the DOWN momentary contact switch until the drive stops automatically.
The upper limit stop is programmed.
6. Press the UP momentary contact switch until the drive stops automatically.
The lower limit has been set.
Setting of the end positions is now complete.
4 | EN
End position setting
Installation Method 3: Upper stop freely adjustable/ fixed lower stop
Installation Method 3: Upper stop freely adjustable/ fixed lower stop
Note: Ensure that the equipment is correctly connected.
STOP
STOP
4. Press the DOWN momentary contact switch again.
Run the blind until shortly before the lower limit stop.
The drive starts up slowly with a short STOP.
1. Move the blind up to approx. 5 cm before the desired upper limit stop.
The drive starts up slowly with a short STOP.
2. Press the UP momentary contact switch again.
Go to the desired upper end position.
It is possible to make corrections using the momentary contact switches.
STOP
5. Approach the lower limit stop.
The drive switches off automatically when it reaches the limit stop.
STOP
STOP
3. Press the DOWN momentary contact switch until the drive stops automatically.
The upper limit stop is programmed.
6. Press the UP momentary contact switch until the drive stops automatically.
The lower limit has been set.
Setting of the end positions is now complete.
EN | 5
Changing/Deleting the limit positions
Changing/Deleting the limit positions
Mains
Blue (neutral conductor
Black (2)
Brown (3)
Green-yellow
3
2
1
3
2
1
1. Switch on mains.
ele ro
2. Move the blind to an intermediate position.
approx.
5 sec.
3. Press both momentary contact switches on the assembly cable
simultaneously.
The drive issues a weak acoustic signal after 5 sec.
Deletion of the limit positions is complete.
6 | EN
Troubleshooting
Troubleshooting
Fault
• Drive stops during travel • Limit positions are not set
• Drive stops after short travel • End position programmed
• Roller shutter stiff
• Drive does not react to travel • No power supply
commands • Thermostat has triggered
• Faulty connection • Drive runs only in one
direction
• Drive does not learn in
limit positions
• Random travel before actual limit
position setting
• Travel to limit position/stop too short
Remedy
• Set limit positions
• Set second limit position
• Check smooth running of the roller shutter
• Check mains voltage
• Allow drive to cool down
• Check connection
• Delete limit positions
Re-programme limit positions
• Drive has to travel to short STOP
EN | 7
EC Declaration of conformity
EC DECLARATION OF CONFORMITY
We hereby declare that the following mentioned product/s meet/s the Machinery Directive 2006/42/EC.
Product designatio n:
Tubular Drive
• RolTop S all versions
• RolTop M all versions
• RolTop L all versions
• RolSmart M all versions
Actuator for shutters Description:
The conformity of the above mentioned products with the relevant health and safety requirements is taken into account by the following directives and standards:
Beuren, 31.05.2012
• Low Voltage Directive 2006/95/EC
DIN EN 60335-2-97 (VDE 0700-97):2009
• DIN EN 14202:2004
Ralph Trost
-CE Manager-, -Representative documentation elero GmbH
Antriebstechnik
Linsenhofer Straße 65
D-72660 Beuren
Fon: +49 7025 13-01
Fax: +49 7025 13-212 [email protected]
www.elero.com
We reserve the right to make technical changes