operating instructions


Add to my manuals
12 Pages

advertisement

operating instructions | Manualzz

OPERATING INSTRUCTIONS

VR50 & VR110

 

 

Index

General information .......................................................................................................................................... 3 

Ice‐lining ........................................................................................................................................................ 3 

Power supply ................................................................................................................................................. 3 

Technical data ............................................................................................................................................... 3 

Unpacking and installation ................................................................................................................................ 3 

Unpacking ...................................................................................................................................................... 3 

Installation .................................................................................................................................................... 3 

Location ......................................................................................................................................................... 3 

Preparation ................................................................................................................................................... 4 

Temperature adjustment ............................................................................................................................. 4 

Cool down of the appliance .......................................................................................................................... 5 

Loading the appliance ....................................................................................................................................... 6 

Starting procedure ........................................................................................................................................ 6 

Temperature control ..................................................................................................................................... 6 

Loading vaccines ........................................................................................................................................... 6 

Defrosting and cleaning. .................................................................................................................................... 6 

Defrosting ...................................................................................................................................................... 7 

Cleaning ......................................................................................................................................................... 7 

 

 

 

 

Trouble shooting. .............................................................................................................................................. 7 

Wire‐diagram. .................................................................................................................................................... 8 

General information

The VR model is a combined ice‐lined vaccine refrigerator. It has compartment for vaccine storage (+2 to 

+8C) equipped with baskets. 

Ice‐lining

The vaccine storage compartment is equipped with a pre installed and water‐filled ice‐lining – ready for  use. The frozen ice lining will maintain temperatures below +10C during power cuts for up to 22 hours ( at  ambient temperatures op to 43C). 

Power supply

The VR is equipped with a heavy‐duty compressor that can operate at voltages 22% below normal voltage. 

See the rating plate. If voltage variations go beyond this range it is recommended to use an automatic  voltage stabilizer. 

Technical data

See the rating plate which is placed at the rear side of the appliance. 

 

Unpacking and installation

Unpacking

 Unpack the appliance and check that it has not been damaged. If you observe any damaged,  inform your supervisor. 

 Check the rating for correct voltage and frequency. 

 Open and remove all internal packing material. 

 

 

Installation

Location

 The appliance must be placed in a well ventilated room, not in direct sunlight and away from other  heating sources. 

 

 Place the appliance on the floor, ensure that it is level. Distance between the wall and the back and  side of the appliance must be minimum 50 mm, and the distance between the wall and the right  side of the appliance must be minimum 100mm. If installed in a room with other  refrigerator/freezers, ensure a minimum distance between the appliances of minimum 200mm. 

Preparation

Check that the plug fits your type of socket. If it does not fit, have a qualified electrician to fit the plug. This  appliance must be earthed. 

Colour code for leads. 

Lead of cord        Pin of plug 

 

230V 

Brown 

Blue 

Green/yellow   

 

 

  115V 

White 

Black 

Green 

 

 

 

 

Connect the plug to the socket and switch on the appliance. 

 

Live 

Neutral 

Earth 

 Check, by listening, that the compressor is running, if it does not run, contacts your supervisor. 

Temperature adjustment

The appliance is equipped with an adjust table thermostat. See figure 2 and figure 3. 

 

 

 

Thermometer for temperature in vaccine compartment. 

 

 

The appliance has a electronic thermostat that controls the temperature in the vaccine compartment. 

Setting 1 applies minimum cold and setting 8 maximum cold. 

1. The green lamp is on when the appliance is connected to the power supply. 

2. Thermometer. 

3. Thermostat for the regulation on the inside temperature with a division from 1‐2‐3‐4 to 8. 

Cool down of the appliance

Before the appliance is loaded with vaccines the ice‐lining in the 4 sides must be frozen. 

To ensure that the ice‐lining in the 4 sides is frozen do the following: 

1. Set the external thermostat at position 8, see figure 3. 

2. Place a thermometer in the top basket. 

3. Check the temperature in the top and bottom basket (must be between +2C and +8C). 

The temperature in the vaccine compartment must always be monitored on the thermometer and within  the range +2C to +8C. 

Recommended settings 

 

Ambient    

Thermostat external 

32C 

43C 

 

Due to tolerance of the thermostat you should always control the temperature during cool down. 

 

 

Loading the appliance

Starting procedure

Connect the main lead to the power supply. The green lamp must light figure 3 (1) to indicate that the  appliance is operating. The thermostat (3) is set on position “8” or adjusted to be between +2C to 8C. Keep  this position for at least 24 hours. 

! The electronic thermostat makes a self test, 20 seconds before the compressor start. 

Temperature control

After 24 hours operating the thermostat setting is adjusted to position “5”. After another 8 hours operation  at thermostat position “5” the inside temperature must be between +2C and +8C. The temperature is  checked with an accurate thermometer which is placed at the bottom of the top vaccine basket. The inside  temperature must be checked regularly according to WHO´s standards and specifications. 

Loading vaccines

When the temperature in the vaccine compartment has stabilized, i.e. and the temperature is between +2C  and +8C and the compressor stops and starts, vaccines can be loaded. 

The vaccines should be placed and arranged in the basket, and remember to place the water filled lids. 

Figure 2. 

 

Figur 2. Top view. 

Defrosting and cleaning.

For the appliance to operate well and to save energy, it is important that it is cleaned and defrosted  regularly. 

When opening the appliance, moisture enters and settles on inner cold surfaces and forms a layer of frost  or ice. The layer of ice makes the refrigerator less efficient and must be removed, “defrosted”. 

 

It is recommended that the appliance be defrosted every third month. 

 

 

 

 

 

 

 

Defrosting

 Before defrosting the vaccines must be moved to another working refrigerator or cold box with  icepacks. Switch off the appliance and pull out the plug. 

 Open the lids and leave open. 

 Keep the lids open to allow the frost to melt completely. 

Cleaning

 Once the appliance is defrosted it must be cleaned. 

 Clean the inside of the appliance with a mixture of lukewarm water and mild detergent. 

 Allow the cleaned parts to dry completely. 

 Clean the outside of the appliance with a mixture of lukewarm water and mild detergent of soap. 

 Close the lid and follow the procedures in “Cool down of the appliance”. 

 

Trouble shooting.

If you observe that the appliance is not working at all or not working properly – please check the following  before contacting your supervisor. 

 Is the green power lamp on? 

 Is the plug correctly in the socket? 

 Has the fuse blown? 

 Is there a power failure? 

 Is the setting of the thermostat correct? See “Temperature adjustment”. 

 Is the appliance placed to close to a heat source? 

If the compressor makes repeated attempts to start without result, then turn off the electricity supply for  about 20 minutes and then try again. Do not try to repair the appliance yourself. 

 

 

Wire‐diagram.

 

 

 

 

 

 

 

 

 

 

 

Notes :

9

Notes :

10

Notes :

11

50 80 030-02-GB

WWW.ARCTIKO.COM

LAMMEFJORDSVEJ 5

DK-6715 ESBJERG N

DENMARK

TEL. +45 70 20 03 28

FAX +45 70 20 03 29

[email protected]

WWW.ARCTIKO.COM

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement