FiberPatch Brochure - ARIA Technologies, Inc.

FiberPatch Brochure - ARIA Technologies, Inc.
FiberPatchTM
Wallmount/Rackmount Pre-Terminated Enclosure
(925) 447-7500
www.ariatech.com
Download the
brochure onto
your smartphone
BECAUSE PERFORMANCE MATTERS
FiberPatch™
1
Wallmount/Rackmount Pre-Terminated Enclosure
DS-BS-7
12/14/2016
FiberPatch™
FiberPatch™ is a compact fiber optic module that is
supplied with adapters for connector patching on one end
and a pre-terminated cable pigtail for splicing on the other
end.
Fiber counts up to 48 and lengths as long as 1 km can be
supplied with OFNR, OFNP, interlocking armor plenum,
indoor/outdoor, OSP non-armored, OSP armored, flat
drop, or alternative jacket cable.
This unique product can eliminate splicing at the building
entrance, customer premise, or cell tower cabinet. It only
requires splicing in a manhole/OSP splice case or building
demarcation point.
Instead of installing conduit, pulling fiber through it, and
then splicing pigtails, FiberPatch™ can be supplied as a
system with cable, conduit, connectors, and an enclosure.
Features
•
ARIA FiberPatch™ is mountable in a variety of hardware and is offered with many pre-terminated cable options.
•
FiberPatch™ is offered in LGX, CCH, and 2X formats. The LGX and CCH formats can be installed in any rackmount
or wallmount enclosure that supports LGX or CCH type cassettes.
•
FiberPatch™ is compact and minimizes the use of crucial rack or wall space. The dimensions for the LGX format are:
4.0 x 5.1 x 1.1 (H”xW”xD”), the dimensions for the CCH format are: 3.8 x 6.1 x 1.4 (H”xW”xD”), and the dimensions for
the 2X format are: 4.0 x 10.5 x 1.1 (H”xW”xD”).
FiberPatch™ is provided on a reel when it is supplied with
a cable length of at least 250 ft
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
FiberPatch™ with Non-Armored Alternative Jacket Cable
and Pulling Eye Shown
FiberPatch™
2
Wallmount/Rackmount Pre-Terminated Enclosure
FiberPatch™
Applications: MDU Drops to Customer Premises
DS-BS-7
12/14/2016
FiberPatch™
SPLWM
Series
Wallmount
Enclosure
In this instance, the pre-terminated FiberPatch™ is located
at the customer premises and the spooled indoor/outdoor
cable is routed outside to the manhole and spliced. This
method eliminates the costly splicing of fibers at both the
building entrance and at the customer premises which
results in savings of thousands of dollars in labor and
materials as well as faster customer hook-up.
In this instance, the pre-terminated FiberPatch™ is located
at the customer premises and the spooled OFNR or OFNP
cable is routed to the basement or building entry point and
is spliced in an indoor rated splice-only enclosure (ARIA
SPLWM shown above). Another splice is performed
at the manhole in an OSP splice case.
Applications: Drops to ITS Cabinets
FiberPatch™
Underground
Splice Enclosure
Drop
Cable
Drop Cable
When cabinets or cell tower shelter racks are loaded to capacity and leave no room for rack mount enclosures, just mount
the ARIA FiberPatch™ on the wall and route the cable to manholes or where splice cases are located for transition to
backbone cables.
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]h.com
FiberPatch™
3
Wallmount/Rackmount Pre-Terminated Enclosure
DS-BS-7
12/14/2016
FiberPatch™
Mounting Options
Wallmount brackets can be utilized
to mount FiberPatch™ directly onto a
wall
Open top Wallmount/Rackmount
brackets can be utilized to mount
multiple modules on a wall
Open top Wallmount/Rackmount
brackets can be utilized to mount
multiple modules in a rack
Open top Wallmount/Rackmount
brackets can be utilized to mount multiple modules in a cell tower cabinet
The shroud accessory protects the
patchcords from damage when the
FiberPatch™ is mounted on a wall
The shroud with door accessory
protects the patchcords and allows
quick access to them after installation
Wallmount brackets can be utilized to mount the 2X
FiberPatch™ directly onto a wall
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
The LGX FiberPatch™ and 2X FiberPatch™ Wallmount/
Rackmount Bracket can be utilized to mount an LGX
FiberPatch™ and a 2X FiberPatch™ on a wall or in a rack
FiberPatch™
4
Wallmount/Rackmount Pre-Terminated Enclosure
DS-BS-7
12/14/2016
FiberPatch™
2X FiberPatch™
The ARIA 2X FiberPatch™ supports up to 24 fibers SC or
48 fibers LC.
It is twice as wide as the standard LGX FiberPatch™ and
it has two locations for pre-terminated cable assemblies to
exit on the back of the cassette.
The enclosure size of the ARIA 2X FiberPatch™ is
4.0 x 10.5 x 1.1 (H”xW”xD”).
Need MPO/MTP® Connectivity?
ARIA’s MPO/MTP® Cassette Module is similar to
FiberPatch™ but provides an MPO/MTP® adapter on the
rear of the cassette instead of the pre-terminated stub.
LC Duplex
Connector
This feature allows the module to interconnect MPO/
MTP® backbones and patch cords.
This product is available in the following configurations:
12 Fiber SC to 12 Fiber MPO/MTP®
12 Fiber LC to 12 Fiber MPO/MTP®
24 Fiber LC to Dual 12 Fiber MPO/MTP®
MPO/MTP®
Connector
Accessories
LGX FiberPatch™ and 2X FiberPatch™ Wallmount/
Rackmount Bracket - P/N: 2X1 LGX W-R BRACKET-OT
FiberPatch™ and 2X FiberPatch™ Wallmount Bracket
P/N: (Ordered with FiberPatch™ Part Number)
19”-23” Extension Bracket for 1RU Wallmount/Rackmount
Bracket (P/N: 19-23-REB-1RU-ALUM)
19”-23” Extension Bracket for 2RU Wallmount/Rackmount
Bracket (P/N: 19-23-REB-2RU-STL0
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
FiberPatch™
5
Wallmount/Rackmount Pre-Terminated Enclosure
DS-BS-7
12/14/2016
FiberPatch™
Accessories (Continued)
3 Module 1RU LGX Wallmount/Rackmount Bracket
P/N: 3XLGXW-RBRACKET-B-OT
2 Module 1RU CCH Wallmount/Rackmount Bracket
P/N: 2XCCHW-RBRACKET-B-OT
6 Module 2RU LGX Wallmount/Rackmount Bracket
P/N: 6XLGXW-RBRACKET-B-OT
4 Module 2RU CCH Wallmount/Rackmount Bracket
P/N: 4XCCHW-RBRACKET-B-OT
2 Module LGX Wallmount Bracket
P/N: 2XLGXWMBRACKET-B-OT
2 Module CCH Wallmount Bracket
P/N: 2XCCHWMBRACKET-B-OT
LGX FiberPatch™ Shroud with Door
P/N: AFP-LGX-SHROUD-WD
LGX FiberPatch™ Shroud
P/N: AFP-LGX-SHROUD
CCH FiberPatch™ Shroud
P/N: AFP-CCH-SHROUD
CCH FiberPatch™ Shroud with Door
P/N: AFP-CCH-SHROUD-WD
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
FiberPatch™
6
Wallmount/Rackmount Pre-Terminated Enclosure
FiberPatch™
Part Number
1
1
1
-AF P-
2
2
-
1 Format
3
3
4
5
5
-
6
6
4 Fiber Type
LGX = LGX FiberPatch™
CCH = CCH FiberPatch™
2XF = 2X FiberPatch™
2 Port Count
06 = 6 Port (SC/FC/ST)
08 = 8 Port (SC/FC/ST)
12 = 12 Port (SC/LC)
24 = 24 Port (FiberPatch™: LC
or 2X FiberPatch™: SC)
48 = 48 Port (2X FiberPatch™: LC)
3 Adapter Type
Singlemode
S = SMF-28e+
B = SMF Bend
Insensitive
G.657.A1
Multimode
1 = 62.5/125μm
2 = 50/125μm
3 = 50/125μm OM3
4 = 50/125μm OM4
5 Stub Cable Type
IR = Indoor Riser Rated
IP = Indoor Plenum Rated
IA = Indoor Interlocking Armor
Plenum Rated*
XR = Indoor/Outdoor Riser Rated
XP = Indoor/Outdoor Plenum
Rated
XC = Indoor/Outdoor Central
Tube Riser Rated
ON = Outdoor Non-Armored
OA = Outdoor Armored Central
Tube
AJ = Outdoor Non-Armored
Alternative Jacket
FD = Outdoor Flat Drop
Singlemode
SCU = SC/UPC
SCA = SC/APC
LCU = LC/UPC
LCA = LC/APC
FCU = FC/UPC
FCA = FC/APC
STU = ST/UPC
Multimode
SCM = SC
LCM = LC
FCM = FC
STM = ST
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
3
- -
DS-BS-7
*Only available in CCH formats
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
6
6
-
7
7
12/14/2016
-
8
8
6 Stub Cable Length
XXXF = XXX feet
XXXM = XXX meters
7 Pulling Eye
PE = Pulling Eye
NP = No Pulling Eye
8 Wallmount Bracket
WB = Wallmount Bracket
Included
NB = No Wallmount Bracket
Included
FiberPatch™
7
Wallmount/Rackmount Pre-Terminated Enclosure
DS-BS-7
12/14/2016
Indoor Cable
Riser or Plenum Rated
Indoor tight buffered cables assure reliable broadband
performance, meet flame retardant safety codes, and
support easy field termination.
Color-Coded
Tight Buffer
Coating (900 µm)
This cable family packages 900μm tight buffered fibers into a
single flame retardant cable. This cable design is available in
both riser rated and plenum rated versions for deployment in
any indoor application.
Flame-Rated
Jacket
Optical Fibers
Aramid Strength Yarns
The tight buffered distribution cable supports standard
installation practices and may be easily terminated using
established field connectorization methods.
Features
•
900μm tight buffered fibers are designed to support rapid field termination
•
Industry standard color coding provides quick, error-free fiber identification
•
Single-Unit designs provide space savings and cost advantages
•
Subunit construction improves organization and termination practices
•
Available with bend-insensitive singlemode and multimode optical fibers
•
Flexible, flame-retardant, and color coded outer jacket
•
Supports all high performance networks including OM4/10 Gigabit Ethernet systems
Fiber Information
Fiber Type
Wavelength
(nm)
Attenuation
(dB/km)
Bandwidth
(MHz km)
1 GbE
Distance
(meters)
10 GbE
Distance
(meters)
Singlemode
1310 / 1383 /
1550
0.7/0.7/0.7
N/A
N/A
N/A
Singlemode
Bend Insensitive
1310 / 1383 /
1550
0.7/0.7/0.7
N/A
N/A
N/A
Multimode
(62.5μm)
850/1300
3.5/1.0
200/500
300/550
33
Multimode
(50μm)
850/1300
3.5/1.5
500/500
550/550
82
Multimode OM3
(50μm)
850/1300
3.5/1.5
1500/500
1000/550
300
Multimode OM4
(50μm)
850/1300
3.5/1.5
3500/500
1100/550
550
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
FiberPatch™
8
Wallmount/Rackmount Pre-Terminated Enclosure
DS-BS-7
12/14/2016
Indoor Cable
Riser Specifications
Fiber Count
Diameter
Cable
Bend Radius Bend Radius Maximum
inches (mm) Weight
Load
No Load
Installation
lb/kft (kg/km) inches (cm) inches (cm) Load lbs
(newtons)
Maximum
Operation
Load lbs
(newtons)
2
0.19 (4.8)
15 (22)
3.8 (9.7)
1.9 (4.9)
148 (660)
44.4 (198)
4
0.22 (5.6)
19 (28)
4.4 (11.2)
2.2 (5.6)
148 (660)
44.4 (198)
6
0.24 (6.0)
21 (31)
4.8 (12.2)
2.4 (6.1)
148 (660)
44.4 (198)
8
0.25 (6.2)
23 (34)
5.0 (12.7)
2.5 (6.4)
148 (660)
44.4 (198)
12
0.28 (7.0)
30 (45)
5.6 (14.3)
2.8 (7.2)
148 (660)
44.4 (198)
18
0.28 (7.0)
35 (51)
5.5 (14.0)
2.8 (7.0)
296 (1320)
88.8 (396)
24
0.32 (8.1)
43 (64)
6.4 (16.3)
3.2 (8.2)
296 (1320)
88.8 (396)
Plenum Specifications
Fiber Count
Diameter
Cable
Bend Radius Bend Radius Maximum
inches (mm) Weight
Load
No Load
Installation
lb/kft (kg/km) inches (cm) inches (cm) Load lbs
(newtons)
Maximum
Operation
Load lbs
(newtons)
2
0.16 (4.2)
9 (13)
3.2 (8.2)
1.6 (4.1)
98.9 (440)
29.6 (132)
4
0.17 (4.3)
14 (21)
3.4 (8.7)
1.7 (4.4)
98.9 (440)
29.6 (132)
6
0.18 (4.7)
15 (22)
3.6 (9.2)
1.8 (4.6)
98.9 (440)
29.6 (132)
8
0.20 (5.0)
18 (27)
4.0 (10.2)
2.0 (5.1)
98.9 (440)
29.6 (132)
12
0.23 (5.8)
22 (33)
4.6 (11.7)
2.3 (5.9)
98.9 (440)
29.6 (132)
18
0.26 (6.5)
32 (48)
5.1 (13.0)
2.6 (6.5)
148 (660)
44.4 (198)
24
0.30 (7.6)
42 (62)
6.0 (15.3)
3.0 (7.7)
148 (660)
44.4 (198)
Specifications
Applications: Versatile Indoor Flame-Rated Cable provides unsurpassed performance for intrabuilding applications that
require crossing floors in multi-level buildings or placement in air handling spaces
Constructions: Single-Unit (≤ 24f); Subunits (≥ 18f); Interlock Armor optional
Flame Ratings: Riser (OFNR / OFCR / FT4); Plenum (OFNP / OFCP / FT6)
Standards: ANSI/ICEA S-83-596, UL-1666, NFPA 262, CSA 22.2 No 230, Telcordia GR-409, RoHS Compliant
Temperatures: Shipping and Storage - Riser/Plenum: -40 °F to +176 °F (-40 °C to +80 °C)
Installation - Riser: +14 °F to +140 °F (-10 °C to +60 °C), Plenum: +32 °F to +140 °F (0 °C to +60 °C)
Operation - Riser: -4 °F to +176 °F (-20 °C to +80 °C), Plenum: +32 °F to +176 °F (0 °C to +80 °C)
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
FiberPatch™
9
Wallmount/Rackmount Pre-Terminated Enclosure
DS-BS-7
12/14/2016
Indoor Cable
Interlocking Armor Plenum Rated
Overview
With a rugged, armored design delivering up to 10 to 13 times the crush resistance of standard fiber optic cable,
interlocking armor fiber cables are ideal for campus & building backbones, data centers and industrial applications.
Interlocking Armor Plenum fiber cables are not governed by fill ratios because they are UL listed as cable assemblies,
allowing a higher concentration of cables in an area compared to conduit. Because the cable is extremely durable and has
an indoor rating, Interlocking Armor Plenum is an excellent choice for campus environments.
Interlocking Armor Plenum fiber cables also provide outstanding flexibility for modifications, alterations and changes,
(MACs) as well as relocations, pathway changes or design modifications after the cable has been pulled, something
conduit cannot easily accommodate.
Protecting optical fiber cables with interlocking armor provides improved network reliability, flexibility and security. It
is a user-friendly, cost and space effective alternative to conduit or plenum innerduct. By installing Interlocking Armor
Plenum fiber cables instead of plenum innerduct or conduit, savings can run from 25-50% in materials, and reduce costly
installation time and labor costs by as much as 60%. This is a significant advantage over traditional installation methods.
Interlocking armor delivers superior crush and rodent resistance as well as security and is available in fiber counts of 6-24.
Specifications
Parameter
Value
Type
Step index singlemode or graded index multimode optical fiber with
protective UV cured acrylate coating
Coating Diameter
245 ± 10 μm
Buffer Jacket
PVC - 900 ± 50 μm (0.0354 in) Outer Diameter (OD)
Configuration
12-24 tight buffer fibers are in a matrix of aramid strength members enclosed
under an inner jacket. Armor and a second jacket is applied
Armor
Aluminum Interlock
Jacket Material, Inner & Outer
Plenum Grade Thermoplastic
Jacket Color
Orange for Multimode, Aqua for OM3, or Yellow for Singlemode
Cable Weight
129 kg/km (87 lb/1000 ft) (12 Fiber)
Cable Outer Diameter
13.3-15.3 mm (0.523-0.602 in) (12-24 Fiber)
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
FiberPatch™
10
Wallmount/Rackmount Pre-Terminated Enclosure
DS-BS-7
12/14/2016
Indoor Cable
Interlocking Armor Plenum Rated
Description
Singlemode
Multimode
62.5 µm
Multimode
50 µm
Multimode
OM3 50 µm
Multimode
OM4 50 µm
Cladding Diameter
125.0 ± 1.0 μm
125.0 ± 2.0 μm
125.0 ± 1.0 μm
125.0 ± 1.0 μm
125.0 ± 1.0 μm
Numerical Aperture
0.12
0.275 ± 0.015
0.200 ± 0.015
0.200 ± 0.015
0.200 ± 0.015
Maximum Attenuation @
850/1300 nm (dB/km)
N/A
3.5/1.0
3.5/1.5
3.0/1.0
3.0/1.0
Minimum Bandwidth @
850/1300 nm (MHz•km)
N/A
200/500
500/500
2000/500
4700/500
100 Mb Transmission
> 5000 @ 1310
distance @ 850/1300 nm (m) nm
300/2000
300/2000
300/2000
300/2000
1 GbE Transmission
> 5000 @ 1310
distance @ 850/1300 nm (m) nm
300/600
550/550
1000/600
1040/600
10 GbE Transmission
> 10,000 @
distance @ 850/1300 nm (m) 1310 nm
36/300
N/A
300/300
550/300
40/100 GbE Transmission
distance @ 850 nm (m)
N/A
N/A
100
150
10k/40k @
1310 nm
Ratings
Flame Listing: Engineering Testing Laboratories (ETL) or Underwriters Laboratories (UL) Type OFNP (Nonconductive
Optical Fiber Plenum Cable) and c(ETL or UL) OFN-FT6 75C
Operating Temperature: -20°C to +75°C
Storage Temperature: -40°C to +85°C
Maximum Loading: Installation - 1335 N (300 lb) & Long Term - 400 N (90 lb).
Minimum Bend Radius: Installation 19.9 cm (7.8 in) & Long Term 13.3 cm (5.2 in).
Compression (crush) Strength: 440 N/cm per TIA/EIA FOTP-41.
Impact: 2 impacts at 5.88 N-m per TIA/EIA FOTP-25.
Cable Flex: 25 cycles per TIA/EIA FOTP-104.
Proof Test: 0.7 GPa (100 kpsi) per TIA/EIA FOTP-31
Applications
Standards
IEEE 802.3ae 10GBASE-X (10 Gb/s)
IEEE 802.3 1000BASE-SX/LX (1 Gb/s)
Fiber Channel FC-PH (1.062 Gb/s)
IEEE 802.3 10BASE-F (10 Mb/s)
IEEE 802.3 FOIRL (10 Mb/s)
FDDI (100 Mb/s)
ATM (155 Mb/s, 622 Mb/s, 1.2/2.4 Gb/s)
ISO/IEC 11801
EN 50173
Telcordia GR-409 & GR-20
ICEA S-104-696
ANSI/ICEA S-87-640
ETL, UL
OFNR/FT4, OFNP/FT6
ANSI/TIA/EIA-568-B.3
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
FiberPatch™
11
Wallmount/Rackmount Pre-Terminated Enclosure
DS-BS-7
12/14/2016
Indoor/Outdoor Cable
Riser or Plenum Rated
Indoor/Outdoor Cable is composed of 2 to 24
colored tight buffers, water blocking aramid
yarn, and a UV resistant black PVC outer
jacket. All component materials meet the EU
RoHS and REACH Directive standards.
Outer Jacket
Tight Buffer
Indoor/Outdoor Cable is UL Listed. OFNR/
OFNP jackets are available. Standard surface
print denotes construction, NEC rating, fiber
type, and includes footage markers.
Water Blocking
Aramid Yarn
Outer Jacket
Water Blocking Aramid Yarn
Tight Buffer
Fiber
Optical Characteristics
Items
Singlemode
Multimode
62.5 µm
Multimode
50 µm
Multimode
OM3 (50 µm)
Multimode
OM4 (50 µm)
Wavelength
(1310/1550) nm
(850/1300) nm
(850/1300) nm
(850/1300) nm
(850/1300) nm
Max. Attenuation
(0.5/0.4) dB/km
(3.5/1.5) dB/km
(3.5/1.5) dB/km
(3.5/1.5) dB/km
(3.5/1.5) dB/km
Bandwidth (EMB)
(High
Performance)
N/A
220 MHz
@850nm
850 MHz
@850nm
2000 MHz
@850nm
4700 MHz
@850nm
Link Length
(10Gb/ s)
N/A
N/A
150 meters
300 meters
550 meters
Cable Characteristics
Parameter
Value
Fiber Count
2, 4, 6, 8, 12, 24
Outer Jacket Material
Flame Retardant PVC
Strength Member
Aramid Yarn
Tight Buffer Material
Flame Retardant PVC
Tight Buffer Color
Available in 12 TIA/ EIA color standard
Nominal Outer Diameter of 2/4/6/8/12/24 fiber count (mm)
4.40 / 4.80 / 5.30 / 5.80 / 6.30 / 8.10
Weight (lbs/ km) of 2/4/6/8/12/24 fiber count - Riser
34 / 45 / 55 / 70 / 94 / 120
Weight (lbs/ km) of 2/4/6/8/12/24 fiber count - Plenum
40 / 52 / 64 / 87 / 115 / 140
Min Bend Radius, Install of 2/4/6/8/12/24 fiber count (cm)
6.6 / 7.2 / 7.95 / 8.7 / 9.45 / 12.15
Min Bend Radius, Operate of 2/4/6/8/12/24 fiber count (cm)
4.40 / 4.80 / 5.30 / 5.80 / 6.30 / 8.10
Application
Riser or Duct
Riser/Plenum Flame Rating
UL1666/ NFPA262
Storage/Operating Temperature
-40 °C to +70 °C
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
FiberPatch™
12
Wallmount/Rackmount Pre-Terminated Enclosure
DS-BS-7
12/14/2016
Indoor/Outdoor Cable
Riser Rated Central Tube
Flame Retardant Jacket
Water Blocking Strength Members
Gel-Filled Buffer Tube Containing up to 12 Fibers
Ripcord
Specifications
Features
Indoor/Outdoor Design
•
Provides additional mechanical protection
•
Can be installed using typical loose tube cable
methods and hardware
Dry Water-Blocking Technology
•
Permits rapid cable preparation and termination
•
Water-blocking materials are easily removed
Flexible Buffer Tube
•
Superior kink resistance
•
Increased flexibility
•
Facilitates route management in closure
•
Eliminates need for closure transportation tubing
Available in Two Different Flame Ratings
•
Riser rated design complies with UL 1666 and is
OFNR and OFN-FT4 rated
•
Low-Smoke, Zero-Halogen design complies with UL
1685 and is OFN-LS and OFN-FT1 rated
All-Dielectric Construction
•
Great for low fiber count applications where armor is
not permitted
•
Easy access to cable core
•
No metallic elements to bond or ground
Performance
•
Tested in accordance with Telcordia GR-20, GR-409
and with relevant EIA/TIA-455 series FOTPs for fiber
optic cables
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
Parameter
Value
Dynamic Bend Radius
20 x Cable OD
Static Bend Radius
10 x Cable OD
Installation Load
Tensile Rating
1800 N (400 lbf)
Residual Load
Tensile Rating
540 N (120 lbf)
Operating
Temperature Rating
-40 to +70 °C
(-40 to +158 °F)
Installation
Temperature Rating
-30 to +60 °C
(-22 to +140 °F)
Storage/Shipping
Temperature Rating
-40 to +75 °C
(-40 to +167 °F)
Fiber Count
12
Buffer Tube O.D.
4.1 mm (0.16 in)
Cable O.D.
8.5 mm (0.34 in)
Cable Weight
68 kg/km (46 lbs/kft)
FiberPatch™
13
Wallmount/Rackmount Pre-Terminated Enclosure
DS-BS-7
12/14/2016
Outdoor Cable
Non-Armored
Polyethylene Outer Jacket
Polyethylene Inner Jacket (double jacket designs only)
Central
Strength
Member
Flexible Buffer
Tubes (2.5 mm)
Out er St rengt h Members (where applicable)
Jacket
(polyethylene)
Dielectric Central Strength Member
Water Blocking Tape
Gel-Filled Buffer Tube Containing up to 12 Fibers
Ripcord
Strength Yarns
Optical Fibers
Specifications
Features
Dry Water-Blocking Technology
Parameter
Value
Fiber Count
2-24
Buffer Tube OD (mm)
2.65
Flexible Buffer Tubes
Single Jacket Cable OD (mm / in)
10.8 / 0.43
•
Increased flexibility and superior kink resistance
82 / 55
•
Facilitates route management in closures
Single Jacket Cable Weight
(kg/km / lb/kft
•
Eliminates need for closure transportation tubes
Single Jacket Max Length (m / ft)
12,800 / 41,984
Double Jacket Cable OD (mm / in)
13 / 0.51
•
Permits rapid cable preparation and termination
•
Water-Blocking materials are easily removed
Medium Density Polyethylene Jacket
•
Low friction installation
Double Jacket Cable Weight
(kg/km / lb/kft)
116 / 78
•
Excellent protection from environmental hazards
Double Jacket Max Length (m / ft)
12,800 / 41,984
Dynamic Bend Radius
20 x Cable OD
Static Bend Radius
10 x Cable OD
Installation Tensile Rating (N / lbf)
2700 / 600
Residual Tensile Rating
800 / 200
Short Term / Long Term Crush
Resistance (N/cm / lbf/in)
220/110 / 125/63
Operation Temp Rating (C)
-40 to +70
Storage/Shipping Temp Rating (C)
-40 to +75
Reverse Oscillated Lay Stranding Method
•
Facilitates access to fibers
All-Dielectric Construction
•
No bonding or grounding required
Performance
•
Meets or exceeds the requirements of Telcordia GR20 and ICEA 640
•
Tested in accordance with the relevant EIA/TIA-455
series FOTPs for fiber optic cables
•
PE-90 compliant for applications that do not require
mid-span tube storage
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
FiberPatch™
14
Wallmount/Rackmount Pre-Terminated Enclosure
DS-BS-7
12/14/2016
Outdoor Cable
Armored - Central Tube
Economical armored protection for lower fiber counts, ideal
for multi-purpose outdoor aerial and underground use near
the network edge.
Water Blocking
(swellable tape)
Armored cable has an efficient design with a single central
loose tube. A better fit and cost-effective alternative for low
fiber count designs, this Central Loose Tube cable provides
easy cable entry and flexible routing for multi-purpose
installation of up to 12 fibers.
Ripcord
Optical Fibers
Armor (corrugated
steel) Optional dual
armor, double jacket
Central Buffer Tube
(3.0 mm gel-free)
Jacket
(polyethylene)
Features
Easy Cable Entry & Preparation
Flexible Routing and Termination
•
Adhesive bond armor protects & improves mid-entry
•
Flexible buffer tubes and strength members
•
Ripcord speeds cable entry & outer jacket removal
•
•
Proven water-blocking with dry core swellable binders
Small diameter & lightweight extends installation
lengths
Meets the Following Standards
•
ANSI / ICEA 640, IEC 60794-3-11, RUS 7 CFR 1755
(RUS LISTED), Telcordia GR20
Temperature Rating
•
Installation: -22 to +140 °F (-30 to +60 °C)
•
Operation: -40 to +158 °F (-40 to +70 °C)
Cable Specifications
Tube
Fiber Count
Construction
Diameter
Cable
Bend Radius Bend Radius Maximum
inches (mm) Weight lb/kft Load inches No Load
Installation
(kg/km)
(cm)
inches (cm) Load
Gel-Free
0.38 (9.7)
2 to 12
63 (94)
8 (20)
6 (15)
600 lbf (2670 N)
Fiber Information
Fiber Type
Wavelength
(nm)
Singlemode
1 GbE
Distance
(meters)
10 GbE
Distance
(meters)
1310 / 1383 / 1550 0.35 / 0.35 / 0.25 N/A
N/A
N/A
Singlemode Bend Insensitive 1310 / 1383 / 1550 0.35 / 0.35 / 0.25 N/A
N/A
N/A
Multimode (62.5μm)
850/1300
3.5/1.0
200/500
300/550
33
Multimode (50μm)
850/1300
3.0/1.0
700/500
800/550
150
Multimode OM3 (50μm)
850/1300
3.0/1.0
1500/500
1000/550
300
Multimode OM4 (50μm)
850/1300
3.0/1.0
3500/500
1100/550
550
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
Attenuation
(dB/km)
Bandwidth
(MHz km)
FiberPatch™
15
Wallmount/Rackmount Pre-Terminated Enclosure
DS-BS-7
12/14/2016
Outdoor Cable
Non-Armored Alternative Jacket
Non-Armored Alternative Jacket is a patented polymer blend
that utilizes non-toxic, non-harmful, and environmentally
friendly food-grade additives to deter squirrels from chewing
on the jacket. The material is intended to make the act of
cutting their teeth back on cable an unpleasant experience
through the combination of taste and sensation.
System operators have traditionally installed a protective
barrier such as squirrel guard around the aerial plant or
endured the expense of moving the plant underground.
Both repairing the damage and the traditional methods
of preventing the damaged are costly and consume man
hours. To reduce the cost of protection and decrease repairs
utilize Non-Armored Alternative Jacket cable.
Overview
Non-Armored Alternative Jacket cable is suitable for direct buried, aerial and conduit applications. The construction
features the use of dry water blocking elements and reduced diameter buffer tubes, yielding a light weight, smaller cable.
The result is a fiber optic cable that is an ideal transmission medium for the outside plant environment.
The fiber and buffer tubes are color coded for easy identification. The all dry cable construction removes the need for
filling gels and flooding compounds from the cable. This significantly reduces cable preparation time and eliminates the
need for solvents and other consumables during cable preparation. These cables are designed to improve the cleanliness
of the work environment and provide full water blocking protection for outside plant applications.
Features
•
Robust cable design
•
Complies with applicable standards
•
Provides very stable low temperature performance
•
Cable withstands typical installation forces with a good safety margin
•
Reduces installation loads due to the reduced weight and diameter
•
Provides performance equivalent to gel-filled cable designs
•
Improves network deployment speed for capturing revenues and starting services sooner
Standards/Compliance/Certifications
ANSI/ICEA S-87-640-2006
EN 187105
Telcordia GR-20-CORE Issue 3
RoHS 2011/65/EU
ISO 9001:2008
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
FiberPatch™
16
Wallmount/Rackmount Pre-Terminated Enclosure
DS-BS-7
Outdoor Cable
Non-Armored Alternative Jacket
Parameter
Value
Cable Type
Stranded loose tube
Construction Type
Non-armored
Subunit Type
Gel-free
Jacket
Black Alternative jacket PE - UV Stabilized
Buffer Tube/Subunit Diameter
2.50 mm | 0.10 in
Cable Weight
66.0 kg/km | 45.0 lb/kft
Diameter Over Jacket
10.10 mm | 0.40 in
Minimum Bend Radius, loaded
15.2 cm | 6.0 in
Minimum Bend Radius, unloaded
10.1 cm | 4.0 in
Tensile Load, long term, maximum
800 N | 180 lbf
Tensile Load, short term, maximum
2700 N | 607 lbf
Tensile Load Test Method
FOTP-33 | IEC 60794-1-2, Section 5
Vertical Rise, maximum
1234.0 m | 4048.0 ft
Environmental Space
Aerial, lashed | Buried
Installation Temperature
-30 °C to +70 °C (-22 °F to +158 °F)
Operating Temperature
-40 °C to +70 °C (-40 °F to +158 °F)
Storage Temperature
-40 °C to +75 °C (-40 °F to +167 °F)
Compression
22 N/mm | 125 lb/in
Compression Test Method
FOTP-41 | IEC 60794-1-2, Section 7
Flex
35 cycles
Flex Test Method
FOTP-24 | IEC 60794-1-2, Section 10
Impact
2.94 N-m | 2.17 ft lb
Impact Test Method
FOTP-25 | IEC 60794-1-2, Section 8
Twist
10 cycles
Twist Test Method
FOTP-85 | IEC 60794-1-2, Section 11
Water Penetration
24 h
Water Penetration Test Method
FOTP-82 | IEC 60794-1-2, Section 24
Cable Freeze
-2 °C | 28 °F
Cable Freeze Test Method
FOTP-98
Heat Age
-40 °C to +85 °C (-40 °F to +185 °F)
Low High Bend
-30 °C to +60 °C (-22 °F to +140 °F)
Low High Bend Test Method
FOTP-28 | IEC 60794-1-2, Section 28
Temperature Cycle
-40 °C to +70 °C (-40 °F to +158 °F)
Temperature Cycle Test Method
FOTP-3 | IEC 60794-1-2, Section 22
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
12/14/2016
FiberPatch™
17
Wallmount/Rackmount Pre-Terminated Enclosure
DS-BS-7
12/14/2016
Outdoor Cable
Flat Drop Cable
Strength Member
Water-Blocking Material
MDPE Outer Jacket
Gel-Filled Buffer Tube (up to 12 Fibers)
Ripcord
Features
Specifications
Easy Access Design
•
Jacket can be easily opened with a knife and the included ripcords
•
Buffer tube is easily separated from the jacket and strength members
All-Dielectric Messengers
•
No bonding or grounding required
•
Flexible and kink resistant
Dry Water-Blocking Technology
•
Permits rapid cable preparation and termination
•
Water-blocking materials are easily removed
Versatile Design
•
Small cross-section and high strength allow good aerial performance
•
Can be pushed or pulled through duct
•
Highly crush-resistant
Dual Strength Member Design
•
More flexible than a single, all-dielectric rod of the same strength
Parameter
Value
Dynamic Bend
Radius
150 mm (5.9”)
Static Bend Radius
100 mm (3.9”)
Installation Load
Tensile Rating
1336 N (300 lbf)
122 mm (400”)
NESC Light Load
District Span Rating
NESC Medium Load 76 mm (250”)
District Span Rating
NESC Heavy Load
46 mm (150”)
District Span Rating
Operating
Temperature Rating
-40 to +70 °C
(-40 to +158 °F)
Installation
Temperature Rating
-30 to +60 °C
(-22 to +140 °F)
Storage/Shipping
Temperature Rating
-40 to +75 °C
(-40 to +167 °F)
Buffer Tube O.D.
2.8 mm (0.11 in)
5.0 mm (0.20 in)
•
Easier to handle and coil than other all-dielectric Figure-8 designs
Cable Thickness
•
A great alternative where steel strength members are not permissible
Cable Width
8.5 mm (0.33 in)
Cable Weight
39 kg/km (26 lbs/kft)
Max. Cable Length
25,000 m (82,000 ft)
Medium Density Polyethylene Jacket
•
Low friction installation
•
Excellent protection from environmental hazards
Sheath Markings
•
Provides positive identification and length verification
Performance
•
RDUP listed (tested in accordance with PE-90)
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
The fastest networks require the best components
That’s why the most powerful data
Visit us at ARIATech.com
centers choose ARIA Technologies
For inquiries email [email protected]
Why should you select ARIA
Technologies as your provider?
•
For nearly 25 years, ARIA has been a trusted
provider of fiber optic cable assemblies, patch panels,
and custom designed and fabricated connectivity
products.
•
ARIA has earned its trusted reputation by focusing on
consistently reliable products and exemplary service.
•
The result of this focus is strong and lasting
relationships with customers and unparalleled
customer satisfaction.
•
It’s not a “one size fits all,” or a “when we can get to
it,” world. We know that time is money and what you
need is what you want. Our custom design process
and swift fabrication capacity qualifies ARIA as not
just another supplier; we are providers of top-tier,
world-class connectivity.
How ARIA Technologies provides for your
business success:
•
ARIA delivers 100% tested products at very
competitive prices.
•
ARIA is a one-stop, full service provider and
has experienced fiber optic engineers on staff.
We develop solutions for speciality connectivity
applications every day.
•
ARIA single mode fiber optic connectors and jumper
assemblies are Telcordia GR-326-CORE, Issue 4
compliant.
•
Supply chain environmental performance is critical.
ARIA products are manufactured with RoHS
compliant materials. ARIA Technologies utilizes a
quality management system that meets or exceeds
the ISO 9001 & TL 9000 international standards.
102 Wright Brothers Ave
Livermore, CA 94551
www.ariatech.com
Phone (925) 447-7500
Fax (925) 447-7511
[email protected]
BECAUSE PERFORMANCE MATTERS
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement