OBZ-30DHN OBZ-60DHN
OBZ-30DHN
OBZ-60DHN
SERVICE NUMBER (1-866-277-7878)
www.oceanbreezecomfort.com
CONTENTS
SAFETY PRECAUTIONS
Warning ..........................................................................................................................................2
Caution ...........................................................................................................................................2
Electrical information ......................................................................................................................3
SAFETY PRECAUTIONS
To prevent injury to the user or others, the following instructions must be followed.
Improper operation may cause harm or property damage.
The seriousness is classified by the following symbols.
DEHUMIDIFIER CONTROL PANEL
Control panel ..................................................................................................................................4
Other features ................................................................................................................................5
PARTS IDENTIFICATION
Parts identification ..........................................................................................................................6
Placing the unit ...............................................................................................................................7
WARNING
This symbol indicates the possibility of death or serious injury.
CAUTION
This symbol indicates the possibility of injury or damage to property.
Please be advised when you see the following symbols.
Never do this.
UNIT OPERATION
Always do this.
Before operating unit ......................................................................................................................7
Removing the collected water ........................................................................................................8
CARE AND MAINTENANCE
WARNING
Cleaning and care ...........................................................................................................................9
TROUBLESHOOTING TIPS
Troubleshooting tips .....................................................................................................................10
Read This Manual
Inside you will find many helpful hints on how to use and maintain your appliance
properly. Just a little preventive care on your part can save you a great deal of time
and money over the life of your unit. You'll find many answers to common problems
in the Troubleshooting Tips section (page10).
!
! CAUTION
This appliance is not intended for use by persons with reduced physical
sensor or mental capabilities, unless they are supervised by a responsible adult
or considered capable enough to operate the appliance safely.
Children should be supervised to ensure that they do not play with the appliance.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
The appliance should be installed in accordance with local wiring regulations.
Contact the authorised service technician for repair or maintenance of this unit.
Do not exceed the rating
of the power outlet or
connection device.
Do not repeatedly turn
the power on and off.
Otherwise, it may cause electric
shock or fire due to excess heat
generation.
It may cause electric shock or fire
due to heat generation.
Do not modify power cord
length or share the outlet
with other appliances
Do not insert or pull out
plug with wet hands.
It may cause electric shock or
fire due to heat generation.
It may cause electric shock.
Plastic parts may melt and cause
a fire.
You should never try to take
apart or repair the unit by
yourself.
!
It may cause fire and electric
shock.
It may cause failure of machine
or electric shock.
It may cause electrical shock
or injury.
Do not use the machine near
flammable gas or combustibles, such
as gasoline, benzene, thinner, etc.
Do not drink or use the
water drained from the unit.
Disconnect the power if
strange sounds, smell, or
smoke comes from it.
It may cause an explosion or fire.
It may cause electric shock or fire.
Do not place the unit near
a heat source.
Before cleaning, turn off
the power and unplug the
unit.
Do not take the water bucket out during operation.
It may cause water to spill and
cause electric shock.
CAUTION
Do not use the unit in small
spaces.
Lack of ventilation can cause
overheating and fire.
1
It contains contaminants and
could make you sick.
Do not damage or use an
unspecified power cord.
Do not put in places where
water may splash onto the
unit.
Water may enter the unit and
degrade the insulation. It may
cause an electric shock or fire.
2
!
Place the unit on a
level, sturdy section
of the floor.
If the unit falls over, it may
cause water to spill and
cause electrical shock or
fire.
DEHUMIDIFIER CONTROL PANEL
SAFETY PRECAUTIONS
NOTE: The control panel of the unit you purchased may be slightly different
depending on the model.
CAUTION
Do not cover the intake or
exhaust openings with
cloths or towels.
!
A lack of air flow can lead
to overheating and fire.
Never insert your finger or
other foreign objects into grills
or openings. Take special care
to warn children of these
dangers.
Always insert the filters
securely. Clean filter
once every two weeks.
Operation without filters
may cause failure.
Do not use in areas
where chemicals are
handled.
Infants, children, elderly people,
and people not sensitive to
humidity.
This will cause the unit
to deteriorate due to
chemicals and solvents
dissolved in the air.
Do not place heavy object on the
power cord and take care so that
the cord is not compressed.
Do not climb up on
or sit on the unit.
There is danger of fire or
electric shock.
It may cause electric shock
or failure of appliance.
!
Care should be taken when
using the unit in a room with
the following persons:
!
You may be injured if you
fall or if the unit falls over.
If water enters the unit, turn
the unit off and disconnect the
power , contact a qualified
service technician.
Do not place flower
vases or other water
container on top of
the unit.
It may cause failure of
appliance or accident.
Water may spill inside the
unit, causing insulation
failure and electrical
shock or fire.
Clean filter
indicator light
2
Filter
Bucket full
indicator light
Display
Filter
Fan
Turbo
Normal
Full
Cont.
High fan
indicator light
Cont.
3
Low fan
indicator light
Off Auto defrost
On
Timer
1
Continuous
operation on
indicator light
7
5
6
4
Auto defrost operation on
indicator light
Timer on/off
indicator light
Fig.1
Electrical Information
The manufacturers’ nameplate is located on the rear panel of the unit and contains electrical and other
technical data specific to this unit.
Be sure the unit is properly grounded. To minimize shock or fire hazards, proper grounding is important.
The power cord is equipped with a three-prong grounding plug for protection against shock
hazards.
Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is
not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician
install the proper receptacle.
Ensure the receptacle is accessible after unit installation.
Do not use extension cords or an adapter plug with this unit. However, if it is necessary to use an
extension cord, use an approved Dehumidifier extension cord only (available at most local hardware
stores).
To avoid the possibility of personal injury, always unplug the unit before installing and/or servicing.
Control panel
5 7
1 Continuous button
: Up / Down Buttons
Humidity Set buttons
The humidity level can be set within a range of
35%RH(Relative Humidity) to 85%RH(Relative
Humidity) in 5% increments.
For drier air, press the pad and set to a lower
percent value(%).
For damper air, press the pad and set a higher
percent value(%).
Press to activate the continuous dehumidifying
operation.
2 Filter button
The check filter feature is a reminder to clean the
Air Filter for more efficient operation. The Filter
light (Clean filter light) will illuminate after 250 hours
of operation. To reset after cleaning the filter, press
the Filter pad and the light will go off.
adjusting humidity levels, the
* When
CONTINUOUS OPERATION INDICATOR LIGHT
MUST BE OFF
3 Fan button
Control the fan speed. Press to select either Turbo
or Normal fan speed. Set the fan control to Turbo for
maximum moisture removal. When the humidity has
been reduced and quiet operation is preferred, set
the fan control to Normal.
3
Power button
Press to turn the dehumidifier on and off.
4
When you press the button to change
operation modes, the unit will make
a beep sound to indicate mode change.
TIMER Set buttons
Use the Up/Down buttons to set the Auto start
and Auto stop time from 0.0 to 24.
6
4
Timer button
Press to initiate the Auto start and Auto stop feature,
in conjunction with the
and
key buttons.
DEHUMIDIFIER CONTROL PANEL
PARTS IDENTIFICATION
Display
Shows the set % humidity level from 35% to 85% or auto
start/stop time (0~24) while setting, then shows the actual
( 5% accuracy) room % humidity level in a range of 30%
RH(Relative Humidity) to 90%RH(Relative Humidity).
Error Codes and Protection Code:
EC- Unit malfunction--Please make sure whether the
environment temperature is suitable for the stated
temperature in the manual or not. If not, please operate
the unit under the stated temperature. If the environment
temperature is normal for the stated temperature, please
call for service.
AS- Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
ES- Temperature sensor error-- Unplug the unit and plug it
back in. If error repeats, call for service.
P2- Bucket is full or bucket is not in right position-- Empty
the bucket and replace it in the right position.
P1- Unit has frost build up-- Allow the unit to run on
AUTO DEFROST mode.
Parts identification
1
2
3
4
5
6
Setting the Timer
When the unit is on, first press the TIMER
button, the TIMER OFF indicator light
illuminates. It indicates the Auto Stop
program is initiated. Press it again for the
TIMER ON indicator light to come on to
indicate the Auto Start is initiated.
Auto Shut Off
The dehumidifier shuts off after 30 seconds when
the bucket is full, or when the bucket is removed
or not placed in the proper position. When the set
humidity is reached, the unit will shut off automatically. For some models,the fan motor will
continue operating.
When the unit is off, first press the Timer
button for the TIMER ON indicator light
to come on to indicate the Auto Start
program. Press again to stop the Timer
and initiate Auto Stop.
Auto Defrost
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
Press or hold the UP or DOWN buttons to
change the Auto timer by half hour increments, up to 10 hours, then at 1 hour
i n c r e m e n t s u p t o 2 4 ho u rs . Th e c o n tr o l
w i ll co u n t d o w n t h e time rema i n in g u n til
the start/stop time.
Wait 3 minutes before resuming operation
After the unit has stopped, it cannot be restarted
immediately. This is to protect the unit from malfunction. Operation will automatically start after
3 minutes.
The selected time will register in 5 seconds
and the system will automatically revert
back to display the previous humidity setting.
W h e n t h e A u t o s t ar t & A u t o st op ti m e s a r e
se t, wit h in th e s am e p ro g r am s eq u e n c e ,
TIMER ON OFF indicator lights both turn on
to show that the TIMER ON and OFF program
is active.
Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel
the Auto Start/Stop function.
Check filter feature
The system starts to count the time once the fan
motor operates. The check filter feature will be lit
when the accumulated operation time achieves
250 hours or more. The Reset light(Clean filter
indicator light) flashes until the filter is cleaned.
Press the Filter button to reset and stop the blinking filter
and Reset light(Clean filter indicator light).
Control panel
5
3
4
Air intake grille
Air outlet grille
5
Air filter (behind the grille)
Water bucket
Handle (both sides)
Fig.2
Water Tank Volume
6.3 pints
12.7 pints
Rear
1
Drain hose outlet
2
Caster wheels
3
Power Cord and plug
4
Band(Used only when
storing the unit.)
1
NOTE: All pictures in the manual are for
explanation purposes only.The actual
design of your unit may be slightly different,
but the operations and functions are the same.
2
3
Accessories:
Drain hose(1pc)
Screw(2pc)
Adapter A(1pc)
When LED display window displays the
c o d e P2, th e A u to Start/Stop function will
a ls o b e ca n c ell ed.
Auto-Restart
If the unit shuts off unexpectedly due to a power outage,
it will restart automatically with the previous function setting
when the power resumes.
6
2
Dehumidifier Capacity
30 / 40 pints
60 pints
Other features
Bucket Full Light
Glows when the bucket is ready to be
emptied, or when the bucket is removed
or not placed in the proper position.
1
Front
6
Fig.3
UNIT OPERATION
UNIT OPERATION
Placing the unit
Removing the collected water
A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed
storage area, such as a closet, unless there is adequate circulation of air in and out of the area.
There are two ways to remove collected water.
1. Use the bucket
When the unit is off, if the bucket is full, the unit will
beep 8 times and the Full indicator light will flash, the
digital display shows P2.
When the unit is on, if the bucket is full, the compressor
Fig.5
turns off and the fan turns off after 30 seconds for drying
2. Hold both sides of the bucket
the water of the condenser, then the unit will beep 8
with even strength and pull it
times and the Full indicator light will flash, the digital
out from the unit.
display shows P2.
Slowly pull out the bucket. Grip the left and right
handles securely, and carefully pull out straight so
water does not spill. Do not put the tank on the floor
because the bottom of the bucket is uneven. Otherwise
the bucket will fall and cause the water to spill.
Throw away the water and replace the bucket. The
bucket must be in place and securely seated for the
Fig.6
dehumidifier to operate.
3. Pour the water out.
The machine will re-start when the bucket is restored
in its correct position.
Drain hose
Adaptor A
NOTES:
When you remove the bucket, do not touch any parts
inside of the unit. Doing so may damage the product.
Be sure to push the bucket gently all the way into the
unit. Banging the bucket against anything or failing to
Fig.7
push it in securely may cause the unit not to operate.
Plastic
cover
When you remove the bucket, if there is some water in
the unit you must dry it.
2. Continuous draining
Water can be automatically emptied into a floor
Drain hose
drain by attaching the unit with a water hose
subassembly
(Id
5/16,not included))with a female threaded
Fig.8
end (ID:M=1 , not included).
Install the drain hose onto the adaptor A (See Fig.7,
placed in the bucket).
Remove the plastic cover from the back drain outlet of
the unit and set aside and remove bucket, then insert
the drain hose through the drain outlet of the unit and
securely press it into the connector on the front of the
unit.(See.Fig.9)
Connector
Tighten the adaptor A and the unit by using two screws
Fig.9
Drain hose
(placed in the bucket).
Install the female threaded end of the water hose into
the adaptor A.(See.Fig.10), then lead the water hose
to the floor drain or a suitable drainage facility.
Water hose
Make sure the hose is secure so there are no leaks.
Direct the hose toward the drain, making sure that
there are no kinks that will stop the water flowing.
Female threaded
Fig.10
Place the end of the hose into the drain and make sure
end
the end of the hose is level or down to let the water flow
smoothly. Do not stop the flow.
Place the bucket back in the unit and make sure
NOTE: When the continuous drain feature
that it is placed correctly.
is not being used, remove the drain hose
Select the desired humidity setting and fan speed
from the outlet.
on the unit for continuous draining to start.
Do not use outdoors.
This dehumidifier is intended for indoor residential
applications only. This dehumidifier should not be used
for commercial or industrial applications.
Place the dehumidifier on a smooth, level floor strong
enough to support the unit with a full bucket of water.
Allow at least 7.9 in. of air space on all sides of the unit
for good air circulation.
Place the unit in an area where the temperature will not
fall below 41 F(5 C). The coils can become covered with
frost at temperatures below 41 F(5 C), which may reduce
performance.
Place the unit away from the clothes dryer, heater or radiator.
Use the unit to prevent moisture damage anywhere books
or valuables are stored.
Use the dehumidifier in a basement to help prevent
moisture damage.
The dehumidifier must be operated in an enclosed
area to be most effective.
Close all doors, windows and other outside openings
to the room.
When using the unit
When first using the dehumidifier, operate the unit
continuously for 24 hours.
This unit is designed to operate in a working
O
O
O
O
environment between 41 F/5 C and 95 F/35 C.
If the unit has been switched off and needs to be
switched on again , allow approximately three
minutes for the unit to resume normally.
Do not connect the dehumidifier to a multiple socket
outlet, which is also being used for other electrical
appliances.
Select a suitable location, making sure you have easy
access to an electrical outlet.
Plug the unit into a electrical socket-outlet with a
grounded connection.
Make sure the Water bucket is correctly fitted otherwise
the unit will not operate properly.
NOTE: When the water in the bucket reaches a certain
level, please be careful to move the machine to avoid the
unit from tipping over.
7
15.7 in. or
more
Air outlet grille
Air intake
grille
7.9 in. or more
7.9 in. or more
7.9 in. or more
7.9 in. or more
Fig.4a
Casters wheels(on the bottom of unit)
Casters wheels can move freely.
Do not force casters to move over carpet,
nor move the unit with water in the bucket.
(The unit may tip over and spill water.)
1. Pull out the bucket a little.
8
TROUBLESHOOTING TIPS
CARE AND MAINTENANCE
Care and cleaning of the dehumidifier
Before calling customer service, review the chart below first yourself.
Turn the dehumidifier off and remove the plug
from the wall outlet before cleaning.
Problem
1. Clean the Grille and Case
Use water and a mild detergent. Do not use bleach
or abrasives.
Do not splash water directly onto the main unit. Doing
so may cause an electrical shock, cause the insulation
to deteriorate, or cause the unit to rust.
The air intake and outlet grilles get soiled easily, so use
a vacuum attachment or brush to clean.
Unit does not start
2. Clean the bucket
Every few weeks, clean the bucket to prevent growth of mold,
mildew and bacteria. Partially fill the bucket with clean water
and add a little mild detergent. Swish it around in the bucket,
empty and rinse.
NOTE: Do not use a dishwasher to clean the bucket.
After cleaning, the bucket must be in place and securely
seated for the dehumidifier to operate.
Dehumidifier does
not dry the air as
it should
What to check
,
Make sure the dehumidifier power plug is pushed completely
into the power outlet.
Check the house fuse/circuit breaker box.
Dehumidifier has reached its preset level or bucket is full.
Water bucket is not in the proper position.
Did not allow enough time to remove the moisture.
Make sure there are no curtains, blinds or furniture blocking
the front or back of the dehumidifier.
The humidity control may not be set low enough.
Check that all doors, windows and other openings are
securely closed.
O
O
Room temperature is too low, below 41 F(5 C).
There is a kerosene heater or something giving off water
vapor in the room.
3. Clean the air filter
Remove the filter every two weeks in normal
operating conditions.
Remove the filter from the top of the unit (See Fig.11a),
or remove the Bucket then pull filter downwards
(See Fig.11b).
Wash the filter with clean water then dry.
Re-install the filter, replace Bucket.
or
Fig. 11a
CAUTION:
DO NOT operate the dehumidifier without a filter
because dirt and lint will clog it and reduce
performance.
4. When not using the unit for long time periods
Turn off the unit, wait one day before emptying
the bucket.
Clean the main unit, water bucket and air filter.
Wrap the cord and bundle it with the band(Fig.12) .
Cover the unit with a plastic bag.
Store the unit upright in a dry, well-ventilated place.
Fig. 11b
The unit makes a
loud noise when
operating
The air filter is clogged.
The unit is tilted instead of upright as it should be.
The floor surface is not level.
Frost appears
on the coils
This is normal. The dehumidifier has Auto defrost feature.
Water on the floor
Hose to connector or hose connection may be loose.
Intend to use the bucket to collect water, but the back
drain plug is removed.
ES, AS, P2, or EC
appear in the display
These are error codes and protection code. See the
DEHUMIDIFIER CONTROL PANEL section.(page 4)
Fig. 12
9
10
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF