® BeveLEDmini PROJECT INFORMATION Covered By US Patents 8,684,570 and 9,671,091 DATE 2221 PROJECT DOWNLIGHT TYPE BeveLED mini Recessed Downlight - Good things come in small packages. BeveLED mini is the smallest member of the BeveLED family with an aperture of only 3”, and is now available with more BeveLED trim finishes, innovative housings, and dimming driver options than ever before. BeveLED mini is perfect for residential, hospitality, and corporate projects. 1” REGRESS DOWNLIGHT DELIVERED PERFORMANCE 14 Watts BeveLEDmini DOWNLIGHT 1" Regress 1" Regress 20 Watts 90+ 90+ 80+ HIGH 80+ HIGH CRI CRI CRI CRI 61 50 51 42 1100 825 1500 1050 850 700 1100 900 2-Step MacAdam Ellipse Color Rendering Index Lumens per Watt Source Lumens Delivered Lumens Color Consistency Performance based on 3000K CCT MULTIPLIER 2700K Bevel Finish Flange Finish Color Rendering Index Multiplier for Lumen Output 3000K 80+ CRI 90+ HIGH CRI 1.00 0.73 3500K 4000K 80+ CRI 90+ HIGH CRI 80+ CRI 80+ CRI 1.00 .80 1.15 1.07 13⁄4"Ø 3"Ø 4"Ø DEEP REGRESS DOWNLIGHT DELIVERED PERFORMANCE (Projected) 14 Watts BeveLEDmini DOWNLIGHT Color Rendering Index Lumens per Watt Source Lumens Delivered Lumens Color Consistency Deep Regress 15⁄8" Regress Performance based on 3000K CCT MULTIPLIER 55º Cutoff Bevel Finish 20 Watts 90+ 90+ 80+ HIGH 80+ HIGH CRI CRI CRI CRI 47 39 43 35 1100 825 1500 1050 675 550 850 700 2-Step MacAdam Ellipse Color Rendering Index Multiplier for Lumen Output 2700K 80+ CRI 90+ HIGH CRI 1.00 0.73 3000K 3500K 4000K 80+ CRI 90+ HIGH CRI 80+ CRI 80+ CRI 1.00 .80 1.15 1.07 Flange Finish 13⁄4"Ø 3"Ø 4"Ø USAI Lighting ® www.usailighting.com [email protected] 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2013. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 06/15/2017 ® BeveLEDmini 2221 DOWNLIGHT ORDERING INFORMATION DEEP REGRESS 1”REGRESS HOW TO SPECIFY Ordering Example: Specify trim code and housing code to order: 2221W - B1- S - 10 - LRTD3 - 9020 - M2 - 27KS - 50 - NC1 - 277V - DIML2 - CB27 TRIM ORDERING INFORMATION TRIM 2221 BEVEL STYLE OPTION LENS – ______ FLANGE FINISH – – 1” REGRESS DOWNLIGHT 2221 Round Downlight 1" Regress W TZ Wet location 1 6” TechZone ceiling compatible (NCSL only) N/A with 01 or 02 flange finishes. 2221 Round Downlight Deep Regress W Wet location 1 01 02 10 13 21 28 RAL B1 1" Regress Bevel, Painted S Solite Die Cast Matches (provided Flange Finish standard) AB1 1" Regress Bevel, F Frosted Black Anodized AC1 1" Regress Bevel, Clear Matte Anodized DEEP REGRESS DOWNLIGHT Clear Matte (AC Bevel only) Black Anodized (AB Bevel Only) White Statuary Bronze Black Metalized Grey Custom Color (specify RAL #) B2 Deep Regress Bevel, Painted Die Cast Matches Flange Finish AB2 Deep Regress Bevel, Black Anodized AC2 Deep Regress Bevel, Clear Matte Anodized 1 Wet location, use with B1 and B2 trims only. HOUSING ORDERING INFORMATION HOUSING CODE WATTAGE – LRTD3 LRTD3 ENGINE CODE COLOR – M2 – 9014 14W LED 9020 20W LED M2 REFLECTOR – 27KS 30KS 35KS 40KS 27KH 30KH HOUSING TYPE – SELECT ONE VOLTAGE – 2700K, 80+ CRI 1” REGRESS DOWNLIGHT FT BabyLED Flat Housing 3000K, 80+ CRI 25 25° beam New Construction2 3500K, 80+ CRI 35 35° beam FTIC BabyLED Flat Housing 4000K, 80+ CRI 50 50° beam IC-Rated/Airtight2 2700K, 90+ CRI (up to 14W maximum) 3000K, 90+ CRI FTA BabyLED Flat Adjustable Housing2 NCSL New Construction Narrow Width2 NC1 New Construction, all in one CP Chicago Plenum2 IC Insulation-Contact Rated / Airtight2 – 120V 277V DEEP REGRESS DOWNLIGHT See performance chart for precise lumen information. USAI Lighting ® 2 Step MacAdam ellipse is standard for all www.usailighting.com [email protected] C20 20° beam Comfort Cutoff C30 30° beam Comfort Cutoff C40 40° beam Comfort Cutoff NC1 New Construction, all in one CP Chicago Plenum2 IC Insulation-Contact Rated / Airtight2 120V 347V 2 N/A with EM 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 DIMMING DRIVER OPTIONS ACCESSORIES – For use with 120V or 277V 1” REGRESS DOWNLIGHT DIML2 0-10V dim, 10% CB27 27" C-Channel Bars 7 (provided standard) CB52 52" C-Channel Bars 7 DIML4 Lutron A 3-wire/ECO, 1% 3 CM27 27” C-Channel Bars DIML4E Lutron 5 ECO, 5% 3 (use with FT or FTIC housing only) DIML4H Lutron H ECO, 1% Fade 3 CM52 52” C-Channel Bars (use with FT or FTIC housing only) DIML6A EldoLED 0-10V, 0.1%, 3 logarithmic / Lutron controls EML Emergency battery 5 DIML6B EldoLED 0-10V, 0.1%, EMLW Emergency battery, 3 linear controls wet location 5 DIML6E EldoLED 0-10V, 1%, TZ 6” TechZone ceiling 3 logarithmic/Lutron controls compatible 6 DIML6F EldoLED 0-10V, 1%, linear 3 controls DIML7 EldoLED DALI, 0.1% 3 DEEP REGRESS DOWNLIGHT For use with 120V only CB27 27” C-Channel Bars DIML3 Lutron A 2-wire, 1% CB52 52” C-Channel Bars 3 120V only EML Emergency battery 5 DIML19 Phase 2-wire dimming, EMLW Emergency battery, 1% 120V only wet location 5 For use with 347V only DIML15 0-10V dim, 1% 347 only3, 4 5 EM requires above ceiling access. For use with NC1 housing only. 3 N/A with FT or FTIC housings 6 4 With NCSL housing only N/A with FTA housing 7 Not available wit FT or FTIC housings © 2013. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 06/15/2017 ® BeveLEDmini 2221 DOWNLIGHT HOUSING INFORMATION NC1, IC AND CP HOUSINGS BELOW ARE FOR USE WITH 1” REGRESS TRIMS & DEEP REGRESS TRIMS New Construction Housing - NC1 IC / Airtight - IC Chicago Plenum - CP 51/2" 71/2" 1" 1" 191/8" 6 /8" 7 8 /2" 1 101/8" 12" 151/2" 11/2" 175/8" (Plan View) HOUSINGS BELOW ARE FOR USE WITH 1” REGRESS TRIMS ONLY (FT, FTIC, FTA AND NCSL ARE NOT AVAILABLE FOR USE WITH DEEP REGRESS) BabyLED Flat Housing - FT BabyLED Flat Adjustable- FTA BabyLED Flat IC-Rated/Airtight - FTIC (14W Maximum) 2” 1" 3” 2” 1" 4” 3” 1" 53/4” 53/4” 10” 107/8 (Plan View) 107/8 (Plan View) 141/2 (Plan View) 141/2 (Plan View) 141/2 (Plan View) 183/16 (Plan View) 55/8" 71/2" Narrow Width - NCSL 61⁄2" plenum depth required 5 4 /8" for service Field Rotatable 90° 115/8" 85/8" /8”-11/2" 5 USAI Lighting ® www.usailighting.com [email protected] 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2013. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 06/15/2017 2221 ® BeveLEDmini DOWNLIGHT SPECIFICATIONS TRIM: 3” round aperture with a 1” regress or deep regress bevel and 1/2” flange, retained by two mounting clips. Die cast aluminum bevel is available in white, statuary bronze, black, and metalized gray painted finishes, with flange painted to match. Also available in black or clear matte anodized finishes, with self-finish or contrasting painted flange. Custom colors are available (provide RAL#). Trim is shipped with a solite lens provided standard. Some examples of standard trim finish options for 2221 are shown below: B1 - Painted Die Cast Trim 10 - White Bevel & Flange B1 - Painted Die Cast Trim 13 - Statuary Bronze Bevel & Flange B1 - Painted Die Cast Trim 21 - Black Bevel & Flange AB1 - Black Anodized Bevel 13 - Statuary Bronze Flange AB1 - Black Anodized Bevel 28 - Metalized Grey Flange AC2 - Clear Matte Anodized Bevel 01 - Clear Matte Flange B1 - Painted Die Cast Trim 28 - Metalized Grey Bevel & Flange AC2 - Clear Matte Anodized Bevel 10 - White Flange AC1 - Clear Matte Anodozed Bevel 01 - Clear Matte Flange AC1 - Clear Matte Anodized Bevel 10 - White Flange AB1 - Black Anodized Bevel 02 - Black Anodized Flange AB2 - Black Anodized Bevel 02 - Black Anodized Flange AB2 - Black Anodized Bevel 13 - Statuary Bronze Flange AB2 - Black Anodized Bevel 28 - Metalized Grey Flange FIELD REPLACEABLE LED LIGHT ENGINE: is serviceable through the aperture without tools. All USAI Lighting Classic White light engines feature industry leading color consistency within a 2-Step MacAdam’s ellipse. FIELD REPLACEABLE DIMMING DRIVER: 0-10V, 100%-10% solid state electronic constant current DIML2 dimming driver with a high power factor provided standard and sources 2mA. Specify 120V or 277V. Driver complies with IEEEC62.41 surge protection. Multiple dimming driver options are available; some on-time delay may be experienced, depending on control system used. EMERGENCY: BeveLED mini emergency lighting battery pack requires above ceiling access for service. Fixtures are provided with a remote test switch with a 24” lead length for location of the test switch. Bodine 17C provides 200mA for 90 minutes; delivers ~450 lumens. EMLW wet location option is available with B1 or B2 trim only. EM option is available with NC1 housings only. Fixtures that have no USAI EM option may be connected to an inverter (by others) for emergency lighting. HOUSING: 1” regress fixture housing options are NC1, IC, CP, FT, FTIC, FTA and NCSL. DEEP regress fixture housing options are NC1, IC, and CP only. FT, FTIC, FTA and NCSL housings are not available with DEEP regress trims. Fabricated of 20 ga. galvanized steel with thru wire J-box, 4 in 4 out at min. 90°C, #12 AWG thru branch circuit wiring. NCSL housing is field rotatable 90° for best fit installation. NCSL with TZ option is compatible with 6” TechZone ceiling systems. IC-rated housings for use with 14W light engines only are rated for direct contact with insulation of R-42 or less. IC-rated housings for use with 20W light engines are rated for direct contact with insulation of R-30 or less. FT housing not for use with through-branch circuit wiring. MOUNTING: Butterfly brackets and adjustable nailer bars with integral nails provided. Nailer bars are extendible from 14” to 24” centers. C-channel bars are optionally available for acoustical ceiling applications. If channel bars are specified for FT or FTIC housing, special reduced height channel bars (CM27 or CM52) will be provided. MAXIMUM CEILING THICKNESS: As noted on housing drawings. CEILING CUT OUT: 3-1/2”Ø NCSL: 3-5/8”Ø WARRANTY: Based on IESNA LM80-2008, BeveLED Mini has a 50,000 hour rated life at 70% lumen maintenance (L70). USAI Lighting Warranty covers replacement parts for 5 years from date of shipment. LISTINGS: Dry/Damp. Wet location option available with B1 and B2 trims only. NRTL/CSA-US tested to UL standards. IBEW union made. NOTES: • Not for use in corrosive environment. • Use of pressure washer voids warranty. PHOTOMETRICS: Consult factory or website for IES files. Tested in accordance with IESNA LM79. USAI Lighting ® www.usailighting.com [email protected] 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2013. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 06/15/2017 DOWNLIGHT ® BeveLEDmini 2221 DELIVERED PERFORMANCE 2221 / 2321 14W 30KS 25° 1” Regress 2221 / 2321 20W 30KS 25° 1” Regress USAI Lighting ® www.usailighting.com [email protected] 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2013. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 06/15/2017 DOWNLIGHT ® BeveLEDmini 2221 DELIVERED PERFORMANCE 2221 / 2321 14W 30KS 35° 1” Regress 2221 / 2321 20W 30KS 35° 1” Regress USAI Lighting ® www.usailighting.com [email protected] 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2013. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 06/15/2017 DOWNLIGHT ® BeveLEDmini 2221 DELIVERED PERFORMANCE 2221 / 2321 14W 30KS 50° 1” Regress 2221 / 2321 20W 30KS 50° 1” Regress USAI Lighting ® www.usailighting.com [email protected] 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2013. USAI, LLC. All rights reserved. All designs protected by copyright. Revised 06/15/2017 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE D2 / DIML2 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D2 / DIML2 LED: 0-10V Dimming Driver Wiring (Dims down to 10%) Manufacturer 120V / 277V Crestron Crestron Crestron Crestron Crestron Leviton Lightolier (Philips) Lutron Product D2 / DIML2 Dimmer Compatibility Chart Dimmed Light Part Number Output Range iLux dimmer expansion module DIN Rail dimmer DIN Rail analog output module 8 Channel dimmer module 8 Channel dimmer module IllumaTech dimmer Vega Diva CLS-EXP-DIMFLV DIN-4DIMFLV4 DIN-A08 GLX-DIMFLV8 GLXP-DIMFLV8 IP710-DLX V2000FAMU DVTV-XX Qty Fixtures Per Dimmer* Use source current per fixture specification sheet to determine number of fixtures per dimmer. Max number of fixtures is limited by dimmer load rating. 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D2 / DIML2 0-10V DIMMING W/RELAY TO SWITCH POWER FIXTURE DIMMER: 0-10V (BY OTHERS) 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT BLACK NEUTRAL WHITE LED DRIVER V+ RED V- BLACK NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. GREEN GND CLASS 2 CONTROL WIRES LINE RELAY (BY OTHERS) NEUTRAL DIMMER: 0-10V w/ POWER SWITCHING D2 / DIML2 0-10V DIMMING (NO RELAY) FIXTURE (BY OTHERS) LINE 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT BLACK NEUTRAL WHITE LED DRIVER V+ RED V- BLACK NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. GREEN GROUND GND NEUTRAL USAI Lighting ® www.usailighting.com [email protected] 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-2 Revised 03/22/2017 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE D3 / DIML3 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D3 / DIML3 LED: Lutron Hi-Lume A-Series 2 Wire Fwd Phase (with neutral) / LED Dimming Driver Wiring (Dims down to 1%) 120V D3 / DIML3 Dimmer Compatibility Chart Manufacturer 120V Only ETC ETC Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Product Part Number Dimmed Light Output Range Sensor+ Cabinet Unison DRd Cabinet Maestro Wireless® 600W dimmer Maestro Wireless® 1000W dimmer HomeWorks® QS adaptive dimmer HomeWorks® QS 600W dimmer HomeWorks® QS 1000 W dimmer Caseta Wireless® Pro 1000W dimmer Stanza® dimmer RadioRA® 2 adaptive dimmer RadioRA® 2 1000 W dimmer myRoom DIN power module HomeWorks® QS wallbox power module Homeworks® DIN power module HomeWorks® wallbox power module GRAFIK Eye® QS control unit GRAFIK Eye® 3000 control unit RPM-4U module RPM-4A module GP dimming panels Ariadni CL 250W dimmer Diva CL 250W dimmer Grafik T CL or RF CL dimmer Nova T CL 250W dimmer ELV10 ELV10 MRF2-6ND-120MRF2-10ND-120HQRD-6NAHQRD-6NDHQRD-10NDPD-10NXDSZ-6NDRRD-6NARRD-10NDMQSE-4A1-D HQRJ-WPM-6D-120LQSE-4A1-D HWI-WPM-6D-120 QSGR-, QSGRJGRX-3100-, GRX-3500HW-RPM-4U-120, LP-RPM-4U-120 HW-RPM-4A-120, LP-RPM-4A-120 Various AYCL-253PDVCL-253P-, DVSCCL-253PGT-250M-, GTJ-250MNTCL-250- 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100%-1% 100%-1% 100%-1% 100%-1% Qty Fixtures Per Dimmer* Fixture Wattage 39W and Less 40W - 80W 1 – 26 1 – 13 1 – 26 1 – 13 1–8 1–4 1 – 13 1–6 1–8 1–4 1–8 1–4 1 – 13 1–6 1 – 13 1–6 1–8 1–4 1–8 1–4 1–6 1–3 1–6 1–3 1 – 26 1 – 13 1–6 1–3 1 – 26 1 – 13 1 – 26 1 – 13 1 – 26 1 – 13 1 – 26 1 – 13 1 – 26 1 – 13 1 – 26 1 – 13 1–8 1–4 1–8 1–4 1–8 1–4 1 – 10 1–5 * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D3 / DIML3 2 WIRE PHASE DIMMING FIXTURE DIMMER: 2 WIRE PHASE (BY OTHERS) LED LINE SWITCHED HOT NEUTRAL GROUND BLACK WHITE DRIVER V+ RED V- BLACK GREEN GND ONLY FOR SWITCHES WITH NEUTRAL NEUTRAL USAI Lighting ® www.usailighting.com [email protected] 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-3 Revised 03/22/2017 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE D4 / DIML4 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D4 / DIML4 LED: Lutron Hi-Lume A-Series LED Driver with 3-Wire FL Control / LED Dimming Driver Wiring (Dims down to 1%) Manufacturer 120V Only ETC ETC Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron 277V Only ETC ETC Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Product D4 / DIML4 3-Wire Dimmer Compatibility Chart Dimmed Light Part Number Output Range Sensor+ Cabinet Unison DRd Cabinet Nova T Nova T Nova Nova Vareo Skylark Diva Ariadni Vierti Maestro Maestro Wireless RadioRA 2 HomeWorks QS Interfaces GP Dimming Panels D20 Dimming module D20F Dimming module NTF-10NTF-103PNF-10NF-103PVF-10SF-10P-, SF-103PDVF-103P-, DVSCF-103PAYF-103PVTF-6AMAF-6AM-, MSCF-6AMMRF2-F6AN-DVRRD-F6AN-DVHQRD-F6AN-DV PHPM-3F-120, PHPM-3F-DV Various 100% - 1% 100% - 1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% Sensor+ Cabinet Unison DRd Cabinet Nova T Nova T Nova Nova Skylark Diva Ariadni Vierti Maestro Maestro Wireless RadioRA 2 HomeWorks QS Interfaces GP Dimming Panels D20 Dimming module D20F Dimming module NTF-10-277NTF-103P-277NF-10-277NF-103P-277SF-12P-277-, SF-12P-277-3 DVF-103P-277-, DVSCF-103P-277AYF-103P-277VTF-6AMAF-6AM-277-, MSCF-6AM-277MRF2-F6AN-DVRRD-F6AN-DVHQRD-F6AN-DV PHPM-3F-DV Various 100% - 1% 100% - 1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% Qty Fixtures Per Control* Fixture Wattage 39W and Less 40W - 80W 1–53 1–26 1–53 1–26 1–41 1 – 20 1–20 1 – 10 1–41 1 – 20 1–20 1 – 10 1–20 1 – 10 1–20 1 – 10 1–20 1 – 10 1–20 1 – 10 1–15 1–7 1–15 1–7 1–15 1–7 1–15 1–7 1–15 1–7 1–41 1 – 20 1–41 1 – 20 40W and Less 41W - 80W 1–53 1–26 1–53 1–26 1–44 1 – 22 1–33 1 – 16 1–44 1 – 22 1–33 1 – 16 1–33 1 – 16 1–33 1 – 16 1–44 1 – 22 1–33 1 – 16 1–20 1 – 10 1–33 1 – 16 1–33 1 – 16 1–33 1 – 16 1–88 1 – 44 1–88 1 – 44 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML4 wiring diagrams continued on next page USAI Lighting ® www.usailighting.com [email protected] 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-4 Revised 03/22/2017 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE D4 / DIML4 Continued ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D4 / DIML4 LED: Lutron Hi-Lume A-Series LED Driver with 3-Wire FL Control / LED Dimming Driver Wiring (Dims down to 1%) D4 / DIML4 3 WIRE PHASE DIMMING FIXTURE DIMMER: 3 WIRE PHASE (BY OTHERS) CAP UNUSED ECOSYS WIRES DIMMED HOT SWITCHED HOT NEUTRAL LINE LED PURPLE GRAY PURPLE ORANGE BLACK WHITE GREEN GROUND DRIVER V+ RED V- BLACK GND NEUTRAL D4 / DIML4 LED: Lutron Hi-Lume A-Series LED Driver with EcoSystem Control / LED Dimming Driver Wiring (Dims down to Manufacturer 120V / 277V Lutron Lutron Lutron Lutron D4 / DIML4 EcoSystem Dimmer Compatibility Chart Dimmed Light Part Number Output Range Product PowPak dimming module Energi Savr Node GRAFIK Eye QS (120V ONLY) Quantum RMJ-ECO32-DV-B QSN-1ECO-S, QSN-2ECO-S QSGRJ-_E, QSGR-_E Various 100%–1% 100%–1% 100%–1% 100%–1% Qty Fixtures Per Control* Fixture Wattage 39W and Less 40W - 80W 1–32 1 – 16 1–64 1 – 32 1–64 1 – 32 1–64 1 – 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D4 / DIML4 EcoSystem CONTROLS ECOSYS BUS E2 E1 E2 FIXTURE E1 WALL CONTROL (BY OTHERS) LINE NEUTRAL CAP UN-USED ORANGE WIRE PURPLE GRAY PURPLE ORANGE BLACK WHITE GREEN LED DRIVER V+ RED V- BLACK GND USAI Lighting ® www.usailighting.com [email protected] 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-4 Revised 03/22/2017 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE D4E / DIML4E and D4H /DIML4H ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D4E / DIML4E LED: Lutron 5 Series EcoSystem LED Driver / LED Dimming Driver Wiring (Dims down to 5%) Manufacturer 120V / 277V Lutron Lutron Lutron Lutron D4E / DIML4E EcoSystem Dimmer Compatibility Chart Dimmed Light Part Number Output Range Product PowPak dimming module Energi Savr Node GRAFIK Eye QS (120V ONLY) Quantum RMJ-ECO32-DV-B QSN-1ECO-S, QSN-2ECO-S QSGRJ-_E, QSGR-_E Various 100%–5% 100%–5% 100%–5% 100%–5% Qty Fixtures Per Control* Fixture Wattage 39W and Less 40W - 80W 1–32 1 – 16 1–64 1 – 32 1–64 1 – 32 1–64 1 – 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D4H / DIML4H LED: Lutron H Series EcoSystem LED Driver with Fade to Black (dims down to 1%) Manufacturer 120V / 277V Lutron Lutron Lutron Lutron D4H / DIML4H EcoSystem Dimmer Compatibility Chart Dimmed Light Part Number Output Range Product PowPak dimming module Energi Savr Node GRAFIK Eye QS (120V ONLY) Quantum RMJ-ECO32-DV-B QSN-1ECO-S, QSN-2ECO-S QSGRJ-_E, QSGR-_E Various 100%–1% 100%–1% 100%–1% 100%–1% Qty Fixtures Per Control* Fixture Wattage 39W and Less 40W - 80W 1–32 1 – 16 1–64 1 – 32 1–64 1 – 32 1–64 1 – 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D4E / DIML4E and D4H / DIML 4H EcoSystem CONTROLS ECOSYS BUS E2 E1 E2 FIXTURE E1 WALL CONTROL (BY OTHERS) LED PURPLE GRAY PURPLE LINE BLACK NEUTRAL WHITE DRIVER V+ RED V- BLACK GREEN GND USAI Lighting ® www.usailighting.com [email protected] 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-4EH Revised 03/22/2017 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE D6A / DIML6A and D6E / DIML6E D6B / DIML6B and D6F / DIML6F ® USAI Lighting IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D6A / DIML6A and D6E / DIML6E LED Dimming Compatibility Table D6A / DIML6A and D6E / DIML6E are linearly programmed dimming drivers for use with logarithmic-style dimming controls (e.g., Lutron and others listed in the table below) D6A / DIML6A = EldoLED SOLOdrive 0-10V control dims from 100% to 0.1% D6E / DIML6E = EldoLED ECOdrive 0-10V control dims from 100% to 1% D6A / DIML6A and D6E / DIML6E Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6A 6E Refer to manufacturer's Lutron Diva DVTV/NFTV/NTFTV with PP-20 99% - 0.1% 1% dimmer load rating for Lutron Energi Savr Node QSN-4T16-S 100% - 0.1% 1% maximum and minimum Lutron GP Dimming Panels TVM2 Module 99% - 0.1% 1% fixture quantities per Lutron Interfaces GRX-TVI w/ GRX3503 100% - 0.1% 1% dimmer. Sensor Switch nIO nIO EZ 100% - 0.1% 1% Enlighted compatible. enlighted Control Unit CU-3E-1R 100% - 0.1% 1% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D6B / DIML6B and D6F / DIML6F LED Dimming Compatibility Table D6B / DIML6B and D6F / DIML6F are logarithmic-programmed dimming drivers for use with linear-style dimming controls (e.g., Crestron, non-Lutron and others listed in the table below) DIMMER:SOLOdrive 0-10V D6B / DIML6B = EldoLED 0-10V control dims from 100% to 0.1% (BY OTHERS) D6F / DIML6F = EldoLED ECOdrive 0-10V control dims from 100% to 1% LED 0-10V (-) GRAY D6B / DIML6B and D6F / DIML6F Dimmer Compatibility Chart 0-10V (+) PURPLE Dimmed Light Qty Fixtures V+ RED SWITCHED HOT SWITCHED HOTNumber DRIVER Manufacturer Product Part Output Range Per Dimmer* VBLACK NEUTRAL WHITE 120V & 277V DIML6B 6F Refer to GREEN 2112U-101 Bush-Jaeger Electronic potentiometer 100% - 0.1% 1% manufacturer's Jung Electronic potentiometer 100% - 0.1% 1% dimmer load GND 240-10 CLASS 2 CONTROL WIRES Leviton IllumaTech dimmer IP710-DLX 100% - 0.1% 1% rating for LINE Lightolier (Philips) Momentum (120V ONLY) ZP600FAM120 100% - 0.1% 1% maximum and RELAY Merten Electronic potentiometer 5729 100% - 0.1% 1% minimum fixture (BY OTHERS) DIML6A, 6B Pass & Seymour Titan CD4FB-W 100% - 0.1% 1% quantities per NEUTRAL TO SWITCH POWER Watt Stopper Miro 0-10V DIMMING W/RELAY DCLV1 100% - 0.1% 1% dimmer. Synergy Wallbox Dimmers ISD BC 100% - 0.1% 1% Enlighted ABB i-bus SD/S 2.16.1 100% - 0.1% 1% compatible. Crestron Modules GLX-DIMFLV8, GLXP-DIMFLV8 100% - 0.1% 1% Crestron Green Light GLPAC-DIMFLV4-, GLPAC-DIMFLV8100% - 0.1% 1% DIML6A, 6B 0-10V (-) Crestron Green Light Power Pack GLPP-DIMFLVEX-PM, GLPP-1DIMFLV2EX-PM, GLPP-1DIMFLV3EX-PM 100% - 0.1% FIXTURE 1% 0-10V DIMMING W/RELAY TO GRAY SWITCH POWER 0-10V (+) PURPLE DIMMER: 0-10V Crestron DIN Rail Analog Output Module DIN-A08 100% - 0.1% 1% V+ RED SWITCHED HOT BLACK Crestron DIN Rail 0-10V Fluorescent Dimmer DIN-4DIMFLV4 100% - 0.1% 1% LEDV- BLACK NEUTRAL WHITE GREEN Crestron iLux 0-10V Dimmer Expansion Module CLS-EXP-DIMFLV 100% - 0.1% 1% DRIVER GND enlighted Control Unit CU-3E-1R 100% - 0.1% 1% CLASS 2 CONTROL WIRES * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and LINEcircuit details. (BY OTHERS) RELAY (BY OTHERS) DIMMING DRIVER WIRING SCHEMES: NEUTRAL NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D6 / DIML6 0-10V DIMMING W/RELAY TO SWITCH POWER D6 / DIML6 0-10V DIMMING (NO RELAY) FIXTURE DIMMER: 0-10V 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT BLACK NEUTRAL WHITE LED DRIVER V+ RED V- BLACK (BY OTHERS) LINE GREEN GROUND GND CLASS 2 CONTROL WIRES LINE FIXTURE DIMMER: 0-10V w/ POWER SWITCHING (BY OTHERS) 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT BLACK NEUTRAL WHITE LED DRIVER V+ RED V- BLACK GREEN GND RELAY (BY OTHERS) NEUTRAL NEUTRAL USAI Lighting ® www.usailighting.com DIML6A, 6B [email protected] 1126 River Road New Windsor, NY 12553 0-10V DIMMING (NO RELAY) DIMMER: 0-10V w/ POWER SWITCHING (BY OTHERS) FIXTURE T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-6 Revised 03/22/2017 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE D7 / DIML7 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D7 / DIML7 LED: EldoLED DALI Dimming Driver Wiring (Dims down to 0.1%) D7 / DIML7 DALI CONTROLS DALI BUS DA DA FIXTURE WALL CONTROL (BY OTHERS) LINE NEUTRAL LED ORANGE (-) ORANGE/WHITE (+) BLACK WHITE GREEN DRIVER V+ RED V- BLACK GND USAI Lighting ® www.usailighting.com [email protected] 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-7 Revised 03/22/2017 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE D15 / DIML15 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D15 / DIML15 LED: 0-10V, 347V Dimming Driver Wiring (Dims down to 1%) 347V Only Manufacturer 347 Acuity Douglas Lighting Hubbell Leviton Leviton Lutron Lutron Product D15 / DIML15 Dimmer Compatibility Chart Dimmed Light Output Range Synergy ISD-BC WPN-5721, WPN-5822 Light Hawk2 LHD-IRS3-N347-xx Illumatech IP710-DLZ with 347V relay Centura Fluorescent Control System Nova NFTV-* dimmer plus 347V relay Diva DVTV-* dimmer plus 347V relay Qty Fixtures Per Dimmer* Use source current per fixture specification sheet to determine number of fixtures per dimmer. Max number of fixtures is limited by dimmer load rating. 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D15 / DIML15 0-10V DIMMING W/RELAY TO SWITCH POWER FIXTURE DIMMER: 0-10V (BY OTHERS) 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT BLACK NEUTRAL WHITE LED DRIVER V+ RED V- BLACK NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. GREEN GND CLASS 2 CONTROL WIRES LINE RELAY (BY OTHERS) NEUTRAL DIML2 0-10V DIMMING (NO RELAY) FIXTURE DIMMER: 0-10V w/ POWER SWITCHING (BY OTHERS) LINE 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT BLACK NEUTRAL WHITE USAI Lighting NEUTRAL DRIVER RED V- BLACK GREEN GROUND ® LED V+ www.usailighting.com [email protected] 1126 River Road New Windsor, NY 12553 GND T 845–565–8500 F 845–561–1130 NOTE: Quickship fixtures are shipped prewired for 0-10V dimming controls. If switched, nondimming operation is desired, cap off purple and gray wires separately at installation. Do NOT cap purple and gray wires together. © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-15 Revised 03/22/2017 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE D19 / DIML19 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D19 / DIML19 LED: Hatch XTC series or equivalent - Forward and Reverse Phase Dimming Driver. Dims down to 1% contingent upon dimmer specification and load. 120V only. D19 / DIML19 2 WIRE PHASE DIMMING FIXTURE DIMMER: 2 WIRE PHASE (BY OTHERS) LED LINE SWITCHED HOT NEUTRAL GROUND BLACK DRIVER WHITE V+ RED V- BLACK GREEN GND ONLY FOR SWITCHES WITH NEUTRAL NEUTRAL D19 / DIML19 Dimmer Compatibility Chart 120V ONLY Forward Phase / TRIAC Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton IPL06-10Z Use fixture wattage per 6613-xxx fixture specification Lutron S-600P sheet to determine S-603P number of fixtures DV-600P per dimmer. Max number DV-603P of fixtures is limited by DVSC-603P dimmer load rating. CT-600P CT-603P 120V ONLY Reverse Phase / ELV Dimming Manufacturer Product Leviton 6615 IPE04-xxx Lutron NTELV-300 NTELV-600 SELV-300P SELV-303P DVELV-300P DVELV-303P USAI Lighting ® www.usailighting.com [email protected] Qty Fixtures Per Dimmer Use fixture wattage per fixture specification sheet to determine number of fixtures per dimmer. Max number of fixtures is limited by dimmer load rating. 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-19 Revised 03/22/2017 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE D2 / DIML2 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D2 / DIML2 LED: 0-10V Dimming Driver Wiring (Dims down to 10%) Manufacturer 120V / 277V Crestron Crestron Crestron Crestron Crestron Leviton Lightolier (Philips) Lutron Product D2 / DIML2 Dimmer Compatibility Chart Dimmed Light Part Number Output Range iLux dimmer expansion module DIN Rail dimmer DIN Rail analog output module 8 Channel dimmer module 8 Channel dimmer module IllumaTech dimmer Vega Diva CLS-EXP-DIMFLV DIN-4DIMFLV4 DIN-A08 GLX-DIMFLV8 GLXP-DIMFLV8 IP710-DLX V2000FAMU DVTV-XX Qty Fixtures Per Dimmer* Use source current per fixture specification sheet to determine number of fixtures per dimmer. Max number of fixtures is limited by dimmer load rating. 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D2 / DIML2 0-10V DIMMING W/RELAY TO SWITCH POWER FIXTURE DIMMER: 0-10V (BY OTHERS) 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT BLACK NEUTRAL WHITE LED DRIVER V+ RED V- BLACK NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. GREEN GND CLASS 2 CONTROL WIRES LINE RELAY (BY OTHERS) NEUTRAL DIMMER: 0-10V w/ POWER SWITCHING D2 / DIML2 0-10V DIMMING (NO RELAY) FIXTURE (BY OTHERS) LINE 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT BLACK NEUTRAL WHITE LED DRIVER V+ RED V- BLACK NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. GREEN GROUND GND NEUTRAL USAI Lighting ® www.usailighting.com [email protected] 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-2 Revised 03/22/2017 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE D19 / DIML19 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). D19 / DIML19 LED: Hatch XTC series or equivalent - Forward and Reverse Phase Dimming Driver. Dims down to 1% contingent upon dimmer specification and load. 120V only. D19 / DIML19 2 WIRE PHASE DIMMING FIXTURE DIMMER: 2 WIRE PHASE (BY OTHERS) LED LINE SWITCHED HOT NEUTRAL GROUND BLACK DRIVER WHITE V+ RED V- BLACK GREEN GND ONLY FOR SWITCHES WITH NEUTRAL NEUTRAL D19 / DIML19 Dimmer Compatibility Chart 120V ONLY Forward Phase / TRIAC Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton IPL06-10Z Use fixture wattage per 6613-xxx fixture specification Lutron S-600P sheet to determine S-603P number of fixtures DV-600P per dimmer. Max number DV-603P of fixtures is limited by DVSC-603P dimmer load rating. CT-600P CT-603P 120V ONLY Reverse Phase / ELV Dimming Manufacturer Product Leviton 6615 IPE04-xxx Lutron NTELV-300 NTELV-600 SELV-300P SELV-303P DVELV-300P DVELV-303P USAI Lighting ® www.usailighting.com [email protected] Qty Fixtures Per Dimmer Use fixture wattage per fixture specification sheet to determine number of fixtures per dimmer. Max number of fixtures is limited by dimmer load rating. 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-19 Revised 03/22/2017
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement