SmartOnline 240/208/120V 6kVA 5.4kW On-Line

Double-Conversion UPS, Low-Voltage Transformer,

Extended Run, SNMP, Webcard, 6U Rack/Tower,

Bypass Switch

MODEL NUMBER: SU6000RT4UTF

Description

Featuring true on-line operation with pure sine wave output, zero transfer time to battery and complete UPS replacement capability with no downtime, the SU6000RT4UTF provides the highest level of protection available for mission-critical equipment from all power problems. It converts incoming AC power to DC, and re-converts it back to filtered AC output with a pure sine wave, providing ultimate protection. The SU6000RT4UTF has a

6kVA/5400W capacity and 16 AC outlets (4 5-15R; 8 5-15/20R; 2 L6-20R; 2 L6-30R). Using the 2U transformer, the SU6000RT4UTF can support both low- and high-voltage equipment.

With its detachable PDU, the SU6000RT4UTF is easily hot-swappable by a user of any skill set—no need for lengthy and expensive service calls, and no downtime if a repair or battery replacement is needed. In bypass mode, the PDU passes power to equipment without the use of the power and battery modules, allowing them to be removed while keeping your application in operation.

UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The SU6000RT4UTF’s runtime can be expanded with external battery packs.

The SU6000RT4UTF features a highly efficient (96%) economy mode setting that can significantly reduce a facility's energy costs by minimizing heat output, reducing cooling requirements and consuming less electricity.

An LCD display with LED indicators enables IT personnel to monitor operating modes and conditions. The

LCD/LED panel rotates for viewing in horizontal rack or vertical tower installations and includes an audible alarm that signals various conditions.

1 / 7

Highlights

Completely user hot-swappable—no service call or technician needed

Included maintenance bypass switch enables live replacement of UPS with zero downtime

Protects rackmount servers, telecom systems and other networking equipment in high-voltage environments

True on-line operation, pure sine wave output and zero transfer time to battery

208/240V input voltage

16 outlets (4 5-15R; 8 5-15/20R;

2 L6-20R; 2 L6-30R)

6kVA/5400W capacity in 6U total form factor with power module and independent, detachable

PDU

Included 2U low-voltage transformer for total equipment compatibility

Hot-swappable power and battery modules

8.5-minute half-load runtime,

2-minute full-load; expandable runtime with external battery packs

Front panel LEDs with detailed

LCD monitoring and control screen

USB, RS232 and SNMP communication ports with included PowerAlert software for complete network power management and control

$250,000 Ultimate Lifetime

Insurance (U.S., Canada, and

Puerto Rico only); 2-year warranty

The SU6000RT4UTF features a USB port and a DB9 port that, when used with Tripp Lite's included PowerAlert software, provide comprehensive network power monitoring and control. An optional SNMPWEBCARD accessory can enable the UPS to operate as an IP managed device.

The unit requires only 6U of rack space in a standard rack enclosure and can be installed in a 2-post rack using the 2POSTRMKITHD accessory (2 required), or in a tower configuration with the 2-9USTAND accessory.

The SU6000RT4UTF comes with $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only) for connected equipment and a 2-year warranty.

Features

Tripp Lite SU6000RT4UTF 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system in a 6U rack/tower compatible configuration (4U power module plus 2U low-voltage transformer; at 208V nominal, output is limited to 4992 watts)

Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise

Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions

Detachable back panel PDU contains input line cord connection, output receptacles and manual bypass switch to support hot-swappable whole UPS replacement with no interruption to connected equipment

L6-30P input plug

UPS supported outlets include two L6-30R, two L6-20R, 8 5-15/20R and 4 5-15R outlets

Included rail kit supports 4U 19 inch rackmount installation in 4 post racks

Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (2 required for SU6000RT4UTF)

Optional 2-9USTAND supports upright tower placement (1 required for SU6000RT4UTF)

Maximum installed rack depth of only 21.8 in. / 55.3 cm

Maintains full-time sine wave output within 2% of selected 208/240V and 120V nominal at 60Hz in double conversion mode

Corrects brownouts to 156V at full load (100V at 50% load or less)

Corrects overvoltages to 290V at full load (300V at 90% load or less)

Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types

High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs

Network-grade AC surge and noise suppression

Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and optional SNMP card slot interfaces

UPS card slot supports one card-based network interface option (part # SNMPWEBCARD) or dry-contact monitoring accessory (part # RELAYIOCARD)

Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces

Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification

Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module)

HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X

Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA (Network

Shutdown Agent) for larger networks and PowerAlert NMS (Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices

Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations

LED/LCD display panel rotates for viewing in rackmount or tower configurations

Supports Emergency Power Off (EPO) via built-in interface

Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement

2 / 7

BP192V12-3U external battery packs are field replaceable and hot swappable

Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)

$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)

Specifications

OUTPUT

Output Capacity Details

Output Volt Amp Capacity (VA)

Output kVA Capacity (kVA)

Output Watt Capacity (Watts)

Output kW Capacity (kW)

Power Factor

Crest Factor

Nominal Output Voltage(s)

Supported

Output capacity de-rates to 4992 watts when used at 208V nominal; Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared

6000

6.0

5400

5.4

.9

3:1

120V; 208V; 240V

Nominal Voltage Details

Frequency Compatibility

Frequency Compatibility Details

Output Voltage Regulation (Line

Mode)

Output Voltage Regulation

(Economy Line Mode)

This configuration requires the Power Module be set to 208 or 240V output voltage; included step-down transformer supports 120V output (when the voltage-selection switch on the transformer module is set to match the 208 or 240V power module setting)

60 Hz

Output frequency regulation +/-0.05Hz (free running)

+/- 2%

+/- 10%

Output Voltage Regulation (Battery

Mode)

Output Receptacles

+/- 2%

Output Receptacle Details

(4) 5-15R; (8) 5-15/20R; (2) L6-20R; (2) L6-30R

Output receptacles and input line cord are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement

Output Circuit Breakers

High voltage 20A breaker protects L6-20R outlets, L6-30R outlets are unbreakered; Low voltage 20A breakers protect 4 5-15/20R outlets each; Low voltage 15A breakers protect 2 5-15/20R outlets each

Output AC Waveform (AC Mode) Pure Sine wave

Output AC Waveform (Battery Mode) Pure Sine wave

INPUT

Rated input current (Maximum Load) 31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V)

Nominal Input Voltage(s) Supported 208V AC; 240V AC

3 / 7

Nominal Input Voltage Description

UPS Input Connection Type

UPS Input Cord Length (ft.)

UPS Input Cord Length (m)

Recommended Electrical Service

Input Phase

Factory configured to 208V

L6-30P

10

3

30A

Single-Phase

BATTERY

Full Load Runtime (min.)

Half Load Runtime (min.)

Expandable Battery Runtime

External Battery Pack Compatibility

DC System Voltage (VDC)

Battery Recharge Rate (Included

Batteries)

Internal UPS Replacement Battery

Cartridge

Battery Access

Battery Replacement Description

Expandable Runtime

2 min. (5400 watts)

8.5 min. (2700 watts)

Runtime is expandable with external battery packs

BP192V1037C-1PH; BP192V12-3U; BP192V1407C-1PH; BP192V557C-1PH; BP192V787C-1PH; BP192V5RT2U

(limit 1)

192

6 hours from 10% to 90% (typical, full load discharge)

RBC5-192

Front panel battery access door

Hot-swappable, user replaceable batteries

Yes

VOLTAGE REGULATION

Voltage Regulation Description

Overvoltage Correction

Undervoltage Correction

Online, double-conversion power conditioning

Corrects overvoltages as high as 300V (<90% load) and 280V (full load)

Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly

USER INTERFACE, ALERTS & CONTROLS

Front Panel LCD Display

Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options;

LED/LCD panel rotates for viewing in rack/tower formats (see manual)

Switches

Alarm Cancel Operation

Audible Alarm

Front Panel LCD

LED Indicators

Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads.

Alarm cancel switch

Unique audible alarms for all major UPS, environmental and power conditions (see manual)

No

6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status

SURGE / NOISE SUPPRESSION

4 / 7

UPS AC Suppression Response

Time

EMI / RFI AC Noise Suppression

Instantaneous

Yes

PHYSICAL

Included Mounting Accessory

Description

Installation Form Factors Supported with Optional Accessories

Two sets of adjustable 4 post 19 inch rackmount installation rails included

2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND)

Optional Mounting Accessory Notes

2 post rackmount installation requires two 2POSTRMKITHD accessories; Tower installation requires one

2-9USTAND accessory

Rackmount Primary Form Factor

UPS Power Module Dimensions

(hwd, in.)

UPS Power Module Dimensions

(hwd, cm)

Installed Whole System Maximum

Rack Depth (in.)

Installed Whole System Maximum

Rack Depth (cm)

Rack Height (U Spaces)

UPS Power Module Weight (lbs.)

6.85 x 17.5 x 20.7

17.4 x 44.5 x 52.6

21.8

55.4

6

116.2

52.8

UPS Power Module Weight (kg)

Stepdown Transformer Dimensions

(hwd / in.)

Stepdown Transformer Dimensions

(hwd / cm)

3.5 x 17.5 x 21.8

8.8 x 44.5 x 55.4

Stepdown Transformer Weight (lbs.) 72.6

Stepdown Transformer Weight (kg) 33

UPS Shipping Dimensions (hwd / in.) 22.5 x 25 x 30

UPS Shipping Dimensions (hwd / cm)

57.2 x 63.5 x 76.2

Shipping Weight (lbs.)

Shipping Weight (kg)

Cooling Method

UPS Housing Material

293

133

Fans

Steel

ENVIRONMENTAL

Operating Temperature Range

Storage Temperature Range

Relative Humidity

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

0 to 95%, non-condensing

5 / 7

AC Mode BTU / Hr. (Full Load)

AC Economy Mode BTU / Hr. (Full

Load)

1767

707

AC Mode Efficiency Rating (100%

Load)

90%

AC Economy Mode Efficiency Rating

(100% Load)

96%

Operating Elevation (ft.)

Audible Noise

Operating Elevation (m)

0-3000m (0 to 10,000 ft.)

60 dBA at front side 1 meter

0-3000 m

COMMUNICATIONS

Communications Interface

Network Monitoring Port Description

PowerAlert Software

Communications Cable

WatchDog Compatibility

USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface

Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports

Included

USB, DB9 serial and EPO cables included

Yes

LINE / BATTERY TRANSFER

Transfer Time

Transfer Time (Economy Mode)

Low Voltage Transfer to Battery

Power (Setpoint)

High Voltage Transfer to Battery

Power (Setpoint)

No transfer time (0 ms.) in online, double-conversion mode

8ms. typical power failure response in optional economy mode

156V (full load) / 100V (50% load or less, derates linearly)

280V (full load) / 300V (90% load or less)

SPECIAL FEATURES

Cold Start (Startup in Battery Mode

During a Power Failure)

High Availability UPS Features

Green Energy-Saving Features

Cold-start operation supported

Automatic inverter bypass; Manual bypass switch; Detachable hot-swap PDU; Hot swappable UPS power module;

Hot swappable batteries

High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation

CERTIFICATIONS

UPS Certifications

UPS Certification Details

WARRANTY

Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of

Hazardous Substances)

IEC 61000-4-5 1995 B Surge Immunity

6 / 7

Product Warranty Period (Worldwide) 2-year limited warranty

Connected Equipment Insurance

(U.S., Canada & Puerto Rico)

$250,000 Ultimate Lifetime Insurance

© 2015 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous improvement.

Specifications are subject to change without notice. Photos may differ slightly from final products.

7 / 7

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Double-conversion (Online)
  • 6 kVA 5400 W
  • 16 AC outlet(s)
  • Rackmount Black

Related manuals

Download PDF

advertisement