Riello Sentinel Dual 8000VA Datasheet

Add to my manuals

advertisement

Riello Sentinel Dual 8000VA Datasheet | Manualzz

LOCAL AREA

NETWORKS

(LAN)

SERVERS DATA

CENTRES

CASH

REGISTERS

INDUSTRIAL

PLCS

ELECTRO-

MEDICAL

DEVICES

EMERGENCY

DEVICES

(Lights/Alarms)

Sentinel Dual

High Power

3.3-10 kVA

single/single-phase and three/single-phase

6

48

Highlights

• Simplified installation

• Operation selection

• High quality output

voltage

• High battery reliability

• Emergency back-up

function

• Battery optimisation

• Power Share

• Low noise level

• On-line (VFI)

SENTINEL DUAL is the best solution for powering mission critical applicaitons and eletro-medical devices requiring maximum power reliability. The UPS is suitable for a wide variety of applications, offering a flexible format (tower or rack), digital display, communication options and user-replaceable batteries.

The SENTINEL DUAL is available in 3.3-4

5-6-8-10 kVA models and uses On-line double conversion technology (VFI): the load is powered continuously by the inverter which supplies a sinusoidal voltage, filtered and stabilised in terms of voltage, form and frequency; in addition, the input and output filters significantly increase the load’s immunity to network disturbances and lightning strikes.

Technology and performance: selectable

Economy Mode and Smart Active Mode functions.

Diagnostics: digital display, RS232 and

USB interface with PowerShield 3 software included, and communication slot for connectivity accessories.

Simplified Installation

• Can be installed on the floor (tower version) or in rackmount cabinets

(rack version). The mimic panel can be rotated (using the key supplied)

• Low noise (<40dBA): can be installed in any environment thanks to its high frequency switching PWM inverter and load-dependent digitally controlled fan.

• External bypas option maintenance (5-

6-8-10 kVA)

• Operation guaranteed up to 40°C (the components are designed for high temperatures and are thus subject to less stress at normal temperatures)

• Two built-in IEC output sockets with thermal protection (5-6- 8-10 kVA)

• Two 10A outpit sockets with Power

Share on the 5-6-8-10 kVA models that can be turned off when the mains power supply fails.

High battery reliability

• Automatic and manual battery test

• Reduced ripple component (detrimental to the batteries) using the “LRCD” (Low

Ripple Current Discharge) system

• Batteries are user replaceable without interruption to the load (Hot Swap)

• Unlimited extendible runtime using matching Battery Boxes

• High hold-up time and wide input voltage range. The batteries are not used during mains power supply failures of <40 ms or within an input voltage range of 84-276V.

Operation selection

Programmed using the software supplied or manually via the front mimic panel

• On-line double conversion Mode: to provide maximum protection.

• ECO Mode:to increase output (up to

98%), operating in line interactive (VI) mode, powering loads from the mains.

• Smart Active Mode: the UPS automatically decides upon the operating mode (VI or VFI) based on the quality of the mains power supply.

• Emergency Mode: the UPS can be selected to function only when mains power fails (emergency mode only)

• Frequency converter (50 or 60 Hz).

Emergency Back-up function

This configuration is designed for emergency systems incljuding lighting, fire detection/exit systems and alarms.

When the mains power supply fails, the inverter begins powering the loads with a progressive start (Soft Start) in order to prevent overload.

Battery optimisation

The wide input voltage range and a high hold-up time minimise battery usage and increase efficiency and battery life; for smaller power breaks, energy is drawn from a group of appropriately-sized capacitors.

High quality output voltage

• Even with non-linear loads (loads with a rest factor of up to 3:1)

• High short circuit current on Bypass

• High overload capacity 150% by inverter (even with mains failure

• Filtered, stabilised and reliable voltage

(double conversion On-line technology

(VFI compliant with IEC 62040-3) with filters for the suppression of atmospheric disturbances.

• Power factor correction: UPS input power factor, close to 1 and sinewave current absorption

Power Share (5-10kVA)

Two configurable IEC output sockets, for runtime optimisation, with the facility to programme the sockets to switch-off low priority loads on mains power failure; alternatively, emergency loads, normally not powered when the mains is present, can be activated.

Low noise output

Using digital PWM control, the speed of the load dependent fans is adjusted depending on the temperature of the two internal heatsinks, to achieve a reduced noise level of 45dB and help extend their operating life.

Other features

• Output voltage can be selected using software (220-230-240V)

• Auto-restart when mains power is restored (programmable via software)

• Bypass on: when the machine is switched off, it automatically goes into bypass and battery charge mode

• Minimum load switch-off

• Low battery warning

• Start-up delay

• Total microprocessor control

• Automatic bypass without interruption

• Use of IMS modules (Insulated Metallic

Substrates)

• Statuses, measurements and alarms available on standard, backlit display.

• UPS digital updating (flash upgradable)

• Input protection through resettable thermal switch

• Standard Back-feed protection: to prevent energy from being fed back to the network

• Manual switching to bypass.

1. Release the mimic panel by applying pressure to the catch

2. Rotate the mimic panel counter in place

90°

3. Rotate the UPS 90°

90°

4. Attach the rack supports www.riello-ups.co.uk

49

50

Advanced communication

• Advanced multi-platform communication for all operating systems and network environments; supervision and shutdown

PowerShield 3 software for Windows operating systems 7, 2008, Vista, 2003,

XP, Linux, Mac OS X, Sun Solaris,

VMware ESX and other Unix operating systems.

• Plug and Play function

• USB Port

• RS232 serial port

• Communications slot

2-YEAR WARRANTY

Options

• Battery cabinets for extended runtimes, with or without batteries

• Telescopic rails for rack cabinet mounting

MODELS models sdl dimensions

(mm)

SDL 3300

SDL 4000

USB PORT

SERIAL PORT

COMMUNICATION SLOT

THERMAL INPUT

PROTECTION

INPUT SOCKET

OUTPUT SOCKET

BATTERY

EXPANSION

CONNECTOR

INPUT CABLE

ACCESS

OUTPUT CABLE

ACCESS

SDL 5000

SDL 6000

Details

SDL 8000

SDL 10000

SDL 6500 TM

SDL 8000 TM

SDL 10000 TM

BB SDL 108-A4 / BB SDL 108-M1 sdl 3300-4000

BB SDL 192-A3/ BB SDL 192-A6 sdl 5000-6000 sdl 6500Tm-8000-8000Tm-10000-10000Tm

Battery box

BC SDL 108-B1 sdl 3300-4000 Tower

175

520

19’’

520

175 660

19’’

660

215

655

4U = 176 mm; 19” = 438 mm

MODELS

PoWeR inPuT nominal voltage minimum voltage nominal frequency

Power factor current distortion

By Pass voltage tolerance frequency tolerance ouTPuT nominal voltage voltage distortion frequency static variation dynamic variation

Waveform crest factor

BaTTeRies charging time oveRload Times

100% < load < 110%

110% < load < 150% load > 150% oTHeR feaTuRes net weight (kg) gross weight (kg) dimensions (hwd) (mm)

Packaging dimensions

(hwd) (mm) line-interactive/ smart active output

Protection devices communication input sockets output socket

Regulations ambient temperature

Relative humidity colour noise level standard equipment provided

SDL 3300 SDL 4000 SDL 5000 SDL 6000 SDL 8000 SDL 10000

3300va/2300W 4000va/2400W 5000va/3500W 6000va/4200W 8000va/6400W 10000va/8000W

220-230-240 Vac

164 Vac @ load 100% / 84 Vac @ load 50%

50 or 60 Hz ±5Hz

> 0.98

≤7%

180 - 264 Vac (selectable in Economy Mode and Smart Active Mode)

Selected frequency ±5% (selectable by user)

220-230-240 Vac selectable

< 3% with linear load / < 6% with non-linear load

50 or 60 Hz selectable

1.5%

≤ 5% in 20 ms

Sinusoidal

3 : 1

4-6 hours

1 minute

4 seconds

0.5 seconds

38

42.5

40

44.5

455 x 175 x 520 tower

175(4U)x19”x483 rack

540 x 620 x 280

62

70

455 x 175 x 660 tower

175(4U)x19”x660 rack

64

72

720 x 530 x (270+15)

94

102

95

103

2 x 455 x 175 x 660 tower

2 x 175(4U)x19”x660 rack

780 x 555 x (270+15)

98%

Overcurrent - short-circuit - overvoltage - undervoltage - thermal - low battery discharge protection

USB / RS232 + slot for communications interface

1 IEC 320 C20

2 IEC 320 C13 + 1 IEC 320 C20

Terminal board

Terminal board + 2 IEC 320 C13

EN 62040-1 EMC EN 62040-2 Directive 73/23 - 93/68 - 2004/108 EC EN 62040-3

0°C / +40°C

< 95% non-condensing

Dark grey RAL 7016

< 40 dBA a 1 m

Two 10A cables; One IEC-16A plug; software; serial cable; keys to release mimic panel; handles kit

< 45 dBA a 1 m

Two cable guides; terminal board connections; One IEC-16A plug; software; serial cable; keys to release mimic panel; handle kit www.riello-ups.co.uk

51

52

MODELS charging time oveRload Times

100% < load < 110%

110% < load < 150% load > 150% oTHeR feaTuRes net weight (kg) gross weight (kg) dimensions (hwd) (mm)

Packaging dimensions

(hwd) (mm) smart active output

Protection devices communication input sockets output socket

Regulations ambient temperature

Relative humidity colour noise level

PoWeR inPuT nominal voltage minimum voltage (f + n) nominal frequency

Power factor

By Pass voltage tolerance frequency tolerance ouTPuT nominal voltage voltage distortion frequency static variation dynamic variation

Waveform crest factor

BaTTeRies

SDL 6500 TM

6500va/5200W

SDL 8000 TM

8000va/6400W

400 Vac Three-phase + N

164 Vac @ load 100% / 84 Vac @ load 50%

50 or 60 Hz ±5Hz

> 0.95

180 - 264 Vac (selectable in Economy Mode or Smart Active Mode)

Selected frequency ±5% (selectable by user)

220-230-240 Vac selectable

< 3% with linear load / < 6% with non-linear load

50 or 60 Hz selectable

1.5%

≤ 5% in 20 ms

Sinusoidal

3 : 1

SDL 10000 TM

10000va/8000W

4-6 hours

1 minute

4 seconds

0.5 seconds

91

99

94

102

2 x 660x175x455 / 2 x 4Ux19”x660

95

103

780 x 555 x (270+15) up to 98%

Overcurrent - short-circuit - overvoltage - undervoltage - thermal - low battery discharge protection

USB / RS232 + slot for communications interface

Terminal board

Terminal board + 2 IEC 320 C13

EN 62040-1 EMC EN 62040-2 Directive 73/23 - 93/68 - 2004/108 EC EN 62040-3

0°C / +40°C

< 95% non-condensing

Dark grey RAL 7016

< 45 dBA a 1 m