IP Video Intercom System
IP
Jacques Technologies Pty Ltd
IP Video Intercom System
IP VIDEO INTERCOM SYSTEM
Jacques IP video intercom system exudes style and is feature packed. The
stylish intercom stations with camera allow for video calling to entrance and
monitor stations within our integrated IP communications system. This allows
for swift system expansion and flexibility to satisfy every client, every time.
As with all Jacques IP communication systems, our video intercom system
fully integrates to numerous third party systems including CCTV, building
& security management, home automation, telephony and access control
systems. This ensures a Jacques IP video intercom system transcends
client expectations as it seamlessly and stylishly integrates within a large
number of applications including commercial, residential, health, public safety
and transport.
VIDEO INTERCOM SYSTEM DIAGRAM
CCTV
Access
Control
System
HLI
I/O
Automation
IP Video
Entrance Station
Any Jacques IP
Communication System
Door & Gate
Access
Unlimited*
IP Controller
Audio Only
Handset Intercom
Ethernet Network
Configured for QoS
Unlimited*
IP Video
Monitor Station
CCTV
Unlimited*
Cameras
Lift Intercom
Unlimited*
IP Video
Entrance Station
Door & Gate
Access
Unlimited*
IP Video
Monitor Station
Unlimited*
VoIP
Phone
*Virtually unlimited. Dependent on server configuration and network bandwidth.
www | jacques.com.au
|2
SYSTEM FEATURES
TEXT MESSAGE
MISSED CALLER IMAGE SNAPSHOT
Receive text messages from building manager/
concierge/control room to video monitor stations.
Receive image snapshot of caller to video monitor
station if call from entrance station is unanswered.
SIP GATEWAY
CCTV CAMERA STREAMS
SIP gateway between the IP video intercom
system and SIP enabled systems/devices, e.g. IP
telephony systems including Avaya and Cisco.
IP
CCTV
Third party IP CCTV camera streams can be
selected and viewed on demand and in real time
via the video monitor station.
RELAY MODULES
ACTIVITY AND EVENTS
Configurable relay modules exist on intercom
stations to activate external equipment. Control
doors, boom gates, lights or signal CCTV
camera presets.
Call activity and system events recorded to an
event log database for call accounting, incident
reports or fault diagnosis.
THIRD PARTY INTEGRATION
FLEXIBLE SYSTEM TOPOLOGY
Fully supported third party integration via High
Level Interface (HLI) to systems such as CCTV
camera, access control, lift control, building and
security management systems.
Rule based call permissions are configurable for
all intercom stations including priority queuing of
all calls. Highly flexible intercom system topology
enables the system to be structured as a mix of
hierarchical and peer to peer call permissions.
TRUE IP DIGITAL TECHNOLOGY
EXPANDABLE SYSTEM ARCHITECTURE
Jacques systems are based on Ethernet network
standards and TCP/IP protocols, which use
commercially
available
network
equipment
and infrastructure.
All Jacques IP communication systems allow for
virtually an unlimited* number of intercom stations
to be connected in a fully integrated system.
*Dependent on server configuration and network bandwidth
www | jacques.com.au
|3
Build your Video
Intercom System
following these simple
steps
IP VIDEO INTERCOM SYSTEM
Begin with an Ethernet Network
configured for QoS.
CONTROLLER PACKAGE
Choose a controller package which can
manage your system size and offer the
functionality you require.
TCH-2MX | JSC-5L
MASTER STATION
Choose your master station. They can make
and receive intercom calls and make
public address announcements.
VMS-750 | PCC-650MX
PA FUNCTIONALITY
Choose your Public Adddress components to
acheive the required functionality.
UAI-3B1 | Amplifiers | Speakers
INTERCOM TERMINALS
Add intercom terminals. They call pre-defined
master stations and can initiate relays within
your system.
VES-75K | VES-741
ACCESSORIES
Choose your accessories. They provide additional
functionality to your system.
Backboxes & Rainhoods
OPTIONAL EXTRAS
Customisation of Graphical User Interfaces (GUI)
and/or
Integration with CCTV & Access Control Systems
|4
CONTROLLERS & SOFTWARE
SYSTEM CONTROLLER MEDIUM
SYSTEM CONTROLLER LARGE
TCH-2MXH | 51660
JSC-5L | 51814
•
IP controller, large, includes JCCP server software for
intercom devices to make and receive calls, more than
80 endpoints supported
Facilitates almost all core functions of the Jacques IP
Communication System
•
Supports high definition audio
•
SATA hard drive
•
Supports high definition audio
•
Segregated air-flow design for optimal unit cooling
•
Fanless and low power consumption
•
SATA hard drive
•
IP controller, up to 80 endpoints
•
Available to administer most Jacques system software
modules & interfaces
•
SOFTWARE
Software modules* manage key functionality of the system and can provide additional functionality. Choose software packages to
achieve system functionality requirements.
DAR
SIP GATEWAY
Echo cancellation for full duplex communication
Interface call audio to third party recording devices
(digital, SIP or analogue)
Intermediate interface allowing for integration of
Jacques system with compatible SIP systems &
devices
Stream background music/entertainment
intercom devices & PA speakers
Implements RFC 3261-Core Session Initiation
Protocol to transfer, convert & filter communication
through
Support for bridge calling allowing a Jacques
device to dial multiple SIP devices however only
allowing one to answer and perform a call
EVENT CONTROLLER
JAS
Provides simplified interfaces for the integration of
external systems & products
Facilitate pre-recorded PA announcements, tones
& warning alarms across a Jacques IP PA system
Feature highly configurable rules to match system
events, simultaneous event triggers, alarms & offline
events
Allows for the uploading of audio files for broadcast
Standard handling of CCTV function
Built timetables of announcements, bells & tones
for broadcast at allocated times to select or all PA
zones
Apply schedules to days, weeks or months
according to a sites broadcast requirements
* Selection of software modules displayed in this brochure. Visit jacques.com.au for a complete list of software
www | jacques.com.au
|5
MASTER STATIONS
PC MASTER STATION
VIDEO MONITOR STATION
PCC-650MX | 51669, PCC-650MXTS | 51720
VMS-750 | 51336, VMS-750H | 51432
PCC-650WIN | 51791, PCC-650WTS | 51857
• Complete intercom call handling functions
• Complete public address functionality
• Make live and pre-recorded announcements
• Broadcast tones, bells & alarms
• Visual display of PA zones (unlimited number of zones
depending on controller)
• Selection and playback of recorded announcements
• Send text messages to video monitor stations
• Diagnostics and reporting
• Receive text messages from building manager/concierge
• Missed caller image snapshot available when call is
unanswered
• View CCTV footage
• Duress calling to predetermined recipient
• Privacy enable/disable to mute calling
• Relay control to let caller through a door or gate
• Intercommunication between devices
• Power saving mode when not in use
• Alarm notifications including device state
• Touchscreen compatible interface
• Map, grid and database views
• Upload multiple site maps to suit application/site
• Customisable layout/functions
Building communication
solutions with Jacques
Video Intercom Systems
www | jacques.com.au
|6
MONITOR STATION VMS-750 (OPTIONAL JHS-1)
PRODUCT CODE 51336, 51432
FEATURES
Text message facility from concierge/building manager*
Caller snapshot image taken, and made visible on monitor station, when call
is unanswered from entrance station
VMS-750
View CCTV footage on monitor station*
Duress calling to concierge/control room/building manager*
Privacy enable/disable feature to mute calling
Intercommunication between devices*
Easy to use, 7” intuitive touchscreen interface
Power saving mode while unit not in use
Call forwarding
Remote mode
VMS-750
JHS-1
OPTIONS
Ergonomic handset - black only (JHS-1)
Customisable GUI
SPECIFICATIONS
Screen
7” TFT colour LCD, 16:9 aspect ratio
Active area: 152 mm x 91 mm
Resolution 800 x 480, 18-bit RGB
LED backlight (white)
Contrast ratio: 400
Brightness: 300 cd/m²
Viewing angle: 120° V, 140° H
Speaker
2x8Ω2W
Speaker Amplifier
50 Hz – 7 kHz (output circuit frequency response -3 dB), 2.5 W
Max. Acoustic Output
88 dBSPL @ 1 m, 0 dBFS 1 kHz (non-clipped) sine wave signal
Microphone
Electret condenser, omnidirectional, sensitivity -56 dB
50 Hz – 7 kHz (input circuit frequency response ±3 dB mic)
Audio Streaming Bandwidth
256 kb/s both ways
Control Buttons
Unlimited* soft buttons, fully customisable GUI control
Auxiliary Functions
Relay contacts (1 x NO/NC), light sensor, privacy mode
Power Input
IEEE 802.3af Power over Ethernet (PoE)
Auxiliary power input: (12 - 32) V d.c.
Power Consumption
10 W max. (2.5 W standby)
Operating Temperature
(0 - 50) °C
Operating Humidity
(20 - 90) % relative humidity (non-condensing)
Cabling
LAN: 4 pair UTP CAT-5/6, multi-strand, 24 AWG, max. 100 m
Power: Figure 8, 0.75 mm² conductors
Dimensions (WxHxD)
280 mm x 172 mm x 33 mm (VMS-750)
340 mm x 172 mm x 64 mm (incl. JHS-1)
Weight
1.2 kg (VMS-750)
1.5 kg (incl. JHS-1)
Material
Plated zinc, acrylic, ABS, zinc plated steel chassis
Finishes
Satin chrome surround, black acrylic screen bezel
Environment
Indoor use only
Mounting Options
Wall mount kit (WMK-1) (included), surface mount backbox (SWE-13/SWE14), desk mount kit (DMS-1/DMS-2)
Fixings
Clips to mounting options and retained with 1 x M3 CSK screw
*Dependent on server configuration and network bandwidth
www | jacques.com.au
|7
ENTRANCE STATION VES-75K/VES-741/VES-742
PRODUCT CODE 51335, 51423, 51468
FEATURES
Attractive slimline design
Wide angle camera
INTERCOM TERMINALS
Two configurable relays that can control lights, gate/door access etc.
Insect resistant microphone/speaker
VES-75K
VES-741
VES-742
3.5” LCD screen
316 type stainless steel
construction
316 type stainless steel
construction
Weather resistant, with
optional rain cover
Weather resistant, with
optional rain cover
Call one master/monitor
station
Call two master/
monitor stations
Backlit keypad
Relay enabled by
entering a PIN code
SPECIFICATIONS
Screen (VES-75K only)
3.5” TFT colour LCD, 4:3 aspect ratio
Active area: 70 mm x 53 mm
Resolution: 320 x 240, 24-bit RGB
LED backlight (white)
Contrast ratio: 400
Brightness: 350 cd/m²
Viewing angle: 120° H, 115° V
Camera
Type: 1/3” CCD image sensor, LED illumination
Resolution: 520 TVL
Sensitivity: 0.1 lux
Functions: AES, AGC, BLC, AWB,
Lens: f = 2.5 mm, f 2.0
Viewing angle: 75° V, 105° H
Speaker
1 x 4 Ω 3 W (VES-75K)
1 x 4 Ω 1 W (VES-741)
Speaker Amplifier
50 Hz – 7 kHz (output circuit frequency response -3 dB), 2.5 W
Max. Acoustic Output
88 dBSPL @ 1 m, 0 dBFS 1 kHz (non-clipped) sine wave signal
Microphone
Electret condenser, omnidirectional, sensitivity -56 dB
50 Hz – 7 kHz (input circuit frequency response ±3 dB mic)
Audio Streaming Bandwidth
256 kb/s both ways
Control Buttons
4 x 4 cap-sense, backlit, touch keypad (VES-75K)
1 x piezo switch, black, 19 mm (VES-741)
2 x piezo switch, black, 19mm (VES-742)
Auxiliary Functions
Relay contacts (2 x NO/NC), power saving modes, light sensor
Power Input
IEEE 802.3af Power over Ethernet (PoE)
Auxiliary power input: (12 - 32) V d.c.
Power Consumption
12 W max. (2.0 W standby) (VES-75K)
8.5 W max. (2.0 W standby) (VES-741)
Operating Temperature
(0 - 50) °C
Operating Humidity
(20 - 90) % relative humidity (non-condensing)
Cabling
LAN: 4 pair UTP CAT-5/6, multi-strand, 24 AWG, max. 100 m
VES-75K
VES-741
Power: Figure 8, 0.75 mm² conductors
Dimensions (WxHxD)
160 mm x 360 mm x 45 mm (VES-75K)
130 mm x 290 mm x 45 mm (VES-741)
Weight
1.9 kg (VES-75K)
1.6 kg (VES-741)
Material
Acrylic and satin chrome plated zinc (VES-75K)
316 stainless steel (3 mm) (VES-741)
Finishes
Bead blasted, electro-polished (VES-741)
Environment
Indoor and outdoor use
Vandal Resistant
Yes (VES-741 only)
Mounting Options
Flush mount backbox (FWE-15), surface mount backbox (SWE-12/SWE9SS), rainhood (SRH-2)
Fixings
6 x M3 CSK screws (VES-75K) (included with purchase of backbox)
6 x M4 security torx screws (VES-741) (included with purchase of backbox)
VES-742
www | jacques.com.au
5
ACCESSORIES
FLUSH MOUNT BACKBOX FWE-1
PRODUCT CODE 60701
SPECIFICATIONS
FWE-1
Suitable For
VSL/VDL/VMI/VES-x4x series
Dimensions (WxHxD)
110 mm x 270 mm x 80 mm
Weight
1 kg
Material
Zincanneal steel
Finishes
Zinc plated and passivated
Environment
Indoor use only
Intercom Mounting Holes
10 x M4 threaded holes
Intercom Fixings
10 x M4 security torx screws (included with purchase of backbox)
Cable Entry
2 x 25 mm Ø holes centred top and bottom
SURFACE MOUNT BACKBOX SWE-9SS
PRODUCT CODE 60708
SPECIFICATIONS
SWE-9SS
Suitable For
VDL/VES /VMI/VSL-x4x series
Dimensions (WxHxD)
130 mm x 290 mm x 79 mm
Weight
1.2 kg
Material
316 stainless steel
Finishes
Linish
Environment
Indoor and outdoor
Intercom Mounting Holes
10 x M4 threaded hole
Intercom Fixings
10 x M4 security torx screws (included with purchase of backbox)
Cable Entry
3 x 25 mm Ø holes centred top, centre and bottom of rear
SURFACE MOUNT BACKBOX SWE-12
PRODUCT CODE 51445
SPECIFICATIONS
SWE-12
www | jacques.com.au
Suitable For
VES-75K
Dimensions (WxHxD)
170 mm x 372 mm x 50 mm
Weight
1.4 kg
Material
Zincanneal steel
Finishes
Powder coated, matte, dark grey
Environment
Indoor and outdoor
Intercom Mounting Holes
6 x M3 threaded holes
Intercom Fixings
6 x M3 CSK stainless steel hex (included with purchase of backbox)
Cable Entry
Drill or cut at installation
|9
SURFACE MOUNT BACKBOX SWE-13/SWE-14
PRODUCT CODE 60716, 60717
SPECIFICATIONS
Suitable For
VMS-750 (SWE-13)
VMS-750 with JHS-1 (SWE-14)
Dimensions (WxHxD)
274 mm x 165 mm x 35 mm (excluding VMS-750 mounting tabs) (SWE-13)
334 mm x 165 mm x 35 mm (excluding VMS-750 mounting tabs) (SWE-14)
Weight
0.6 kg (SWE-13)
0.7 kg (SWE-14)
Material
Zincanneal steel
Finishes
Powder coated, matte, dark grey
Environment
Indoor use only
Intercom Mounting Holes
1 x M3 threaded hole
Intercom Fixings
1 x M3 CSK black machine screw (included with purchase of backbox)
Cable Entry
214 mm x 115 mm cut out (SWE-13)
273 mm x 115 mm cut out(SWE-14)
SWE-13
SWE-14
DESK MOUNT KIT DMS-1/DMS-2
PRODUCT CODE 51400, 51461
SPECIFICATIONS
DMS-1
DMS-2
Suitable For
VMS-750 (DMS-1)
VMS-750 with JHS-1 (DMS-2)
Dimensions (WxHxD)
267 mm x 156 mm x 88 mm (DMS-1)
327 mm x 156 mm x 88 mm (DMS-2)
Weight
0.4 kg (DMS-1)
0.5 kg (DMS-2)
Material
Electro gal
Finishes
Powder coated satin black
Environment
Indoor use only
Intercom Mounting Holes
1 x M3 threaded hole
Intercom Fixings
1 x M3 CSK black machine screw (included with purchase of kit)
Cable Entry
100 mm x 88 mm cut out
RAINHOOD SRH-2
PRODUCT CODE 51190
SPECIFICATIONS
SRH-2
www | jacques.com.au
Suitable For
VES-741/VSL-x4xW+ series
Dimensions (WxHxD)
138 mm x 296 mm x 135 mm
Weight
1.7 kg
Material
316 stainless steel
Finishes
Linish
Environment
Outdoor
Intercom Mounting Holes
6 x M4 threaded hole
Intercom Fixings
6 x M4 security torx screws (included with purchase of backbox)
| 10
SYSTEM SPECIFICATIONS
IP
SYSTEM CAPACITY
Intercom Stations
Unlimited*
Master Stations
Unlimited*
Stored Announcements
Unlimited*
Call Queue Size
Unlimited*
Groups
Unlimited*
Simultaneous Conversations
Unlimited*
Audio Communication Between any
endpoint
Auxiliary Channels
Yes +
16 (typically up to 4 live captured sources)
AUDIO CHARACTERISTICS
Frequency Response
200 Hz - 7 kHz ± 3 dB
Transmission Format
Real-Time Transport Protocol (RTP) Streaming
Digital Audio Format - Voice
A-law compressed PCM 16 kHz sampling rate
Audio Streaming Bandwidth
128 kb/s one way, 256 kb/s full duplex
Acoustic Echo Cancellation
Yes
VIDEO CHARACTERISTICS
Multi-Standard Video Codec
MPEG-4 part 2, simple profile; H.264 baseline profile; H.263 part
3
Video Streaming Bandwidth
500 kb/s - 6 Mb/s
CALL HANDLING
Call Topologies
Intercom/hierarchical/peer/public address/zoned
Call Priorities
256 priority levels
Call Features (Basic)
Auto-answer, hold, forward, diversion, directory, group call,
caller-ID, bridged call appearance
Call Features (Specialised)
Isolate nuisance callers, covert monitor, dynamic group call,
stored announcements, master call, remote mode, priority
queuing, selective answer of call waiting
NETWORK
Addressing
TCP/IP IPV4, static or dynamic (DHCP)
Interface Media
IEEE 802.3 10/100 Mb/s Ethernet
Standards
IEEE802.1P LAN Layer 2 prioritisation
IEEE802.1Q Virtual LAN
RTP - Real-Time Transport Protocol (RFC3550/3551)
TOS - IPV4 Type of Service (RFC791)
DTMF - RTP payload for DTMF digits (RFC2833)
Multicast - IP Multicasting (RFC1112)
Diffserv - Differentiated Services (RFC2474/2475)
NTP - Network Time Protocol (RFC1305)
IGMPv2 - Internet Group Management Protocol v2 (RFC2236)
DHCP - Dynamic Host Configuration Protocol (RFC1531)
CABLING
Power Input/Ethernet
4 pair UTP CAT-5/5e/6, multi-strand, 24 AWG - max. 100m
*Dependent on server configuration and network bandwidth
+Dependent on system configuration and permissions granted
www | jacques.com.au
| 11
ADDITIONAL RESOURCES
2017
p | +61 7 3846 8400
e | [email protected]
www | jacques.com.au
JSD-0006 | JULY 2017
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement